WorldWideScience

Sample records for program combines frequency

  1. Laser frequency stabilization by combining modulation transfer and frequency modulation spectroscopy.

    Science.gov (United States)

    Zi, Fei; Wu, Xuejian; Zhong, Weicheng; Parker, Richard H; Yu, Chenghui; Budker, Simon; Lu, Xuanhui; Müller, Holger

    2017-04-01

    We present a hybrid laser frequency stabilization method combining modulation transfer spectroscopy (MTS) and frequency modulation spectroscopy (FMS) for the cesium D2 transition. In a typical pump-probe setup, the error signal is a combination of the DC-coupled MTS error signal and the AC-coupled FMS error signal. This combines the long-term stability of the former with the high signal-to-noise ratio of the latter. In addition, we enhance the long-term frequency stability with laser intensity stabilization. By measuring the frequency difference between two independent hybrid spectroscopies, we investigate the short-and long-term stability. We find a long-term stability of 7.8 kHz characterized by a standard deviation of the beating frequency drift over the course of 10 h and a short-term stability of 1.9 kHz characterized by an Allan deviation of that at 2 s of integration time.

  2. The generalized algebraic modal combination (GAC) rule validation program

    International Nuclear Information System (INIS)

    Mertens, P.G.; Culot, M.V.; Sahgal, S.; Tinic, S.

    1991-01-01

    With R.G. 1.92 the NRC imposes to use the absolute values of the modal responses when performing Response Spectra modal combination with coupling factors derived from the current heuristic, stationary or pseudo-stationary random vibration models. This results in overly conservative calculations in the case of closely spaced modes of opposite signs, a case frequently encountered in dynamic analyses in particular when systems with close modal frequencies have a small mass ratio. A new generalised algebraic combination (GAC) formula and its associated coupling factor have been theoretically derived by the first author. It is based on a non-stationary, non-white noise random vibration model which fully accounts for all the time and frequency dependent aspects of the time histories. This should allow the conservative use of algebraic signs in the modal combination over the whole frequency range, and allow a derogation to the current NRC R.G. 1.92 practice to use absolute signs. The use of the industry wide accepted RS method with the GAC rule will result in more economical and safer NPPs through the reduction of an excessive and unrealistic number of seismic restraints and avoidance of prematurely fatigued plants. It is envisaged to use the GAC seismic response combination method for the evaluation of the seismic response of auxiliary class one lines attached to the primary coolant loop piping of the Beznau 1 and 2 nuclear power plants. Since the plant is in operation, it is imperative to use a methodology which is conservative but still as realistic as possible. The paper presents an introduction to the GAC rule and some aspects of the validation program, which will jointly be undertaken by WESI and NOK for obtaining acceptance by the Swiss Safety Authorities for a seismic qualification program. (author)

  3. Decoding a combined amplitude modulated and frequency modulated signal

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a method for decoding a combined AM/FM encoded signal, comprising the steps of: combining said encoded optical signal with light from a local oscillator configured with a local oscillator frequency; converting the combined local oscillator and encoded optical...... signal into one or more electrical signals by means of at least one opto-electrical converter having a predefined frequency bandwidth, thereby providing an amplified and encoded electrical signal having one or more encoded signal current(s), where one type of states have a higher oscillation frequency...... than other type of states; rectifying the encoded signal current(s), thereby obtaining an encoded power spectrum, wherein said power spectrum has different states, such as "0"-states and "1"-states, with different power levels such that they can be discriminated, said local oscillator frequency...

  4. System for combining laser beams of diverse frequencies

    International Nuclear Information System (INIS)

    1980-01-01

    A system is described for combining laser beams of different frequencies into a number of beams each comprising laser radiation having components of each of the different frequencies. The system can be used in laser isotope separation facilities. (U.K.)

  5. 45 CFR 1306.34 - Combination program option.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Combination program option. 1306.34 Section 1306... START PROGRAM HEAD START STAFFING REQUIREMENTS AND PROGRAM OPTIONS Head Start Program Options § 1306.34 Combination program option. (a) Combination program option requirements: (1) Grantees implementing a...

  6. Structural Health Monitoring Based on Combined Structural Global and Local Frequencies

    Directory of Open Access Journals (Sweden)

    Jilin Hou

    2014-01-01

    Full Text Available This paper presents a parameter estimation method for Structural Health Monitoring based on the combined measured structural global frequencies and structural local frequencies. First, the global test is experimented to obtain the low order modes which can reflect the global information of the structure. Secondly, the mass is added on the member of structure to increase the local dynamic characteristic and to make the member have local primary frequency, which belongs to structural local frequency and is sensitive to local parameters. Then the parameters of the structure can be optimized accurately using the combined structural global frequencies and structural local frequencies. The effectiveness and accuracy of the proposed method are verified by the experiment of a space truss.

  7. Are Chinese Correlative Conjunctions Psychologically Real? An Investigation of the Combination Frequency Effect.

    Science.gov (United States)

    Kong, Lingyue; Zhang, John X; Zhang, Yongwei

    2016-08-01

    The present study used an online grammaticality judgment task to examine whether Chinese discontinuous correlative conjunctions are psychologically real in mental lexicon. High- and low-frequency discontinuous correlative conjunctions were compared with random combinations differing in combination frequencies but matched for constituent word frequency. Forty graduate students participated in the study. Results showed that responses were faster and more accurate for high-frequency correlative conjunctions than low-frequency ones, but the effects were absent for random combinations. The results indicate that Chinese discontinuous correlative conjunctions have psychological reality in mental lexicon in addition to the representation of their constituent words, and that grammatical functions of correlative conjunctions may be a critical factor for the formation of such holistic representations. © The Author(s) 2016.

  8. Weighted combination of LOD values oa splitted into frequency windows

    Science.gov (United States)

    Fernandez, L. I.; Gambis, D.; Arias, E. F.

    In this analysis a one-day combined time series of LOD(length-of-day) estimates is presented. We use individual data series derived by 7 GPS and 3 SLR analysis centers, which routinely contribute to the IERS database over a recent 27-month period (Jul 1996 - Oct 1998). The result is compared to the multi-technique combined series C04 produced by the Central Bureau of the IERS that is commonly used as a reference for the study of the phenomena of Earth rotation variations. The Frequency Windows Combined Series procedure brings out a time series, which is close to C04 but shows an amplitude difference that might explain the evident periodic behavior present in the differences of these two combined series. This method could be useful to generate a new time series to be used as a reference in the high frequency variations of the Earth rotation studies.

  9. IPTV program recommendation based on combination strategies

    Directory of Open Access Journals (Sweden)

    Li Hao

    2018-01-01

    Full Text Available As a new interactive service technology, IPTV has been extensively studying in the field of TV pro-gram recommendation, but the sparse of the user-program rating matrix and the cold-start problem is a bottleneck that the program recommended accurately. In this paper, a flexible combination of two recommendation strategies proposed, which explored the sparse and cold-start problem as well as the issue of user interest change over time. This paper achieved content-based filtering section and collaborative filtering section according to the two combination strategies, which effectively solved the cold-start program and over the sparse problem and the problem of users interest change over time. The experimental results showed that this combinational recommendation system in optimal parameters compared by using any one of two combination strategies or not using any combination strategy at all, and the reducing range of MAE is [2.7%,3%].The increasing range of precision and recall is [13.8%95.5%] and [0,97.8%], respectively. The experiment showed better results when using combinational recommendation system in optimal parameters than using each combination strategies individually or not using any combination strategy.

  10. Triple-Frequency Code-Phase Combination Determination: A Comparison with the Hatch-Melbourne-Wübbena Combination Using BDS Signals

    Directory of Open Access Journals (Sweden)

    Chenlong Deng

    2018-02-01

    Full Text Available Considering the influence of the ionosphere, troposphere, and other systematic errors on double-differenced ambiguity resolution (AR, we present an optimal triple-frequency code-phase combination determination method driven by both the model and the real data. The new method makes full use of triple-frequency code measurements (especially the low-noise of the code on the B3 signal to minimize the total noise level and achieve the largest AR success rate (model-driven under different ionosphere residual situations (data-driven, thus speeding up the AR by directly rounding. With the triple-frequency Beidou Navigation Satellite System (BDS data collected at five stations from a continuously-operating reference station network in Guangdong Province of China, different testing scenarios are defined (a medium baseline, whose distance is between 20 km and 50 km; a medium-long baseline, whose distance is between 50 km and 100 km; and a long baseline, whose distance is larger than 100 km. The efficiency of the optimal code-phase combination on the AR success rate was compared with that of the geometry-free and ionosphere-free (GIF combination and the Hatch-Melbourne-Wübbena (HMW combination. Results show that the optimal combinations can always achieve better results than the HMW combination with B2 and B3 signals, especially when the satellite elevation angle is larger than 45°. For the wide-lane AR which aims to obtain decimeter-level kinematic positioning service, the standard deviation (STD of ambiguity residuals for the suboptimal combination are only about 0.2 cycles, and the AR success rate by directly rounding can be up to 99%. Compared with the HMW combinations using B1 and B2 signals and using B1 and B3 signals, the suboptimal combination achieves the best results in all baselines, with an overall improvement of about 40% and 20%, respectively. Additionally, the STD difference between the optimal and the GIF code-phase combinations decreases

  11. Effect of combined mutagenic treatments on sensitivity and mutation frequency in rice

    International Nuclear Information System (INIS)

    Gopinathan Nair, V.

    1977-01-01

    Rice seeds were subjected to two sets of combination treatments of radiations and NMH. The effects of mutagenic treatments in the M 1 and M 2 generations were recorded and discussed. Mutation frequencies estimated as number of mutations per 100 M 1 years were not higher than the values expected on the basis of additive effects. When estimated as number of mutants per 100 M 2 plants, the frequencies revealed more than additive effects. The synergistic effect on mutant frequencies was due to increase in the segregation ratio of mutants. This effect was more pronounced at the higher dose combinations of fast neutrons and NMH. (author)

  12. Combined failure acoustical diagnosis based on improved frequency domain blind deconvolution

    International Nuclear Information System (INIS)

    Pan, Nan; Wu, Xing; Chi, YiLin; Liu, Xiaoqin; Liu, Chang

    2012-01-01

    According to gear box combined failure extraction in complex sound field, an acoustic fault detection method based on improved frequency domain blind deconvolution was proposed. Follow the frequency-domain blind deconvolution flow, the morphological filtering was firstly used to extract modulation features embedded in the observed signals, then the CFPA algorithm was employed to do complex-domain blind separation, finally the J-Divergence of spectrum was employed as distance measure to resolve the permutation. Experiments using real machine sound signals was carried out. The result demonstrate this algorithm can be efficiently applied to gear box combined failure detection in practice.

  13. Development of a new Frequency Program in the CERN Proton Synchrotron

    CERN Document Server

    Sundal, Magnus; Larsen, Ragnhild; Johnsen, Ragnar

    The development of a new frequency program in the Proton Synchrotron (PS) is a project that links existing and new infrastructure in the first particle accelerator built at CERN. In a particle synchrotron, the magnetic field strength of the bending magnets and the revolution frequency of the particles are coupled to keep a circulating beam at fixed orbit during acceleration. The frequency program delivers a revolution frequency based on the measurements of the bending magnets. Ongoing renovations in the magnet measurement system are changing the way the information is distributed from the magnets. Once implemented, it will represent a step towards fully digital beam controls. This project involves development of both Very High Speed Integrated Circuit Hardware Description Language (VHDL) firmware and Printed Circuit Boards (PCBs) in the form of FPGA Mezzanine Cards (FMCs) to adapt the frequency program to the new transmission protocol called White Rabbit. The White Rabbit is a network solution that provides s...

  14. Modulated Source Interferometry with Combined Amplitude and Frequency Modulation

    Science.gov (United States)

    Gutierrez, Roman C. (Inventor)

    1998-01-01

    An improved interferometer is produced by modifying a conventional interferometer to include amplitude and/or frequency modulation of a coherent light source at radio or higher frequencies. The phase of the modulation signal can be detected in an interfering beam from an interferometer and can be used to determine the actual optical phase of the beam. As such, this improvement can be adapted to virtually any two-beam interferometer, including: Michelson, Mach-Zehnder, and Sagnac interferometers. The use of an amplitude modulated coherent tight source results in an interferometer that combines the wide range advantages of coherent interferometry with the precise distance measurement advantages of white light interferometry.

  15. Investigation of Combined High-Frequency and Arc Discharges

    International Nuclear Information System (INIS)

    Taran, V.S.; Nezovibatko, Yu.N.; Marinin, V.G.; Shvets, O.M.; Ridozub, V.N.; Gasilin, V.V.

    2001-01-01

    In this paper we analyze experiment with arc and high-frequency (HF) plasma sources carried out in modified devise of the ''Bulat'' type. The HF-sources and combined discharges have attracted considerable attention for surface cleaning and coating. The utilization of such discharges allows decreasing droplet fraction formation and providing better adhesion and microhardness values. The existence of HF-field in plasma allows obtaining either conductive or dielectric coatings and they can be deposited on any substrates. (author)

  16. EFFECTS OF ELECTROSTIMULATION AND PLYOMETRIC TRAINING PROGRAM COMBINATION ON JUMP HEIGHT IN TEENAGE ATHLETES

    Directory of Open Access Journals (Sweden)

    Emilio J. Martínez-López

    2012-12-01

    Full Text Available The purpose of this study was to examine the effects of eight- week (2 days/week training periods of plyometric exercises (PT and neuromuscular electrostimulation (EMS on jump height in young athletes. Squat jump (SJ, counter movement jump (CMJ and drop jump (DJ were performed to assess the effects of the training protocols 98 athletes (100 & 200m and 100m & 110m hurdles voluntarily took part in this study, 51 males (52% and 47 females (48%, 17.91 ± 1.42 years old, and 5.16 ± 2.56 years of training experience. The participants were randomly assigned to four different groups according to the frequency and the timing of the stimulation. Analysis of covariance was used to analyze the effects of every training program on jump height. Our findings suggest that compared to control (Plyometrics (PT only, the combination of 150Hz EMS + PT simultaneously combined in an 8 week (2days/week training program, we could observe significant jump height improvements in the different types of strength: explosive, explosive-elastic, and explosive-elastic-reactive. The combination of PT after < 85 Hz EMS did not show any jump height significant increase in sprinters. In conclusion, an eight week training program (with just two days per week of EMS combined with plyometric exercises has proven useful for the improvement of every kind of vertical jump ability required for sprint and hurdles disciplines in teenage athletes

  17. Combining program visualization with programming workspace to assist students for completing programming laboratory task

    Directory of Open Access Journals (Sweden)

    Elvina Elvina

    2018-06-01

    Full Text Available Numerous Program Visualization tools (PVs have been developed for assisting novice students to understand their source code further. However, none of them are practical to be used in the context of completing programming laboratory task; students are required to keep switching between PV and programming workspace when they need to know how their code works. This paper combines PV with programming workspace to handle such issue. Resulted tool (which is named PITON has 13 features extracted from PythonTutor, PyCharm, and student’s feedbacks about PythonTutor. According to think-aloud and user study, PITON is more practical to be used than a combination of PythonTutor and PyCharm. Further, its features are considerably helpful; students rated these features as useful and frequently used.

  18. 3D measurement using combined Gray code and dual-frequency phase-shifting approach

    Science.gov (United States)

    Yu, Shuang; Zhang, Jing; Yu, Xiaoyang; Sun, Xiaoming; Wu, Haibin; Liu, Xin

    2018-04-01

    The combined Gray code and phase-shifting approach is a commonly used 3D measurement technique. In this technique, an error that equals integer multiples of the phase-shifted fringe period, i.e. period jump error, often exists in the absolute analog code, which can lead to gross measurement errors. To overcome this problem, the present paper proposes 3D measurement using a combined Gray code and dual-frequency phase-shifting approach. Based on 3D measurement using the combined Gray code and phase-shifting approach, one set of low-frequency phase-shifted fringe patterns with an odd-numbered multiple of the original phase-shifted fringe period is added. Thus, the absolute analog code measured value can be obtained by the combined Gray code and phase-shifting approach, and the low-frequency absolute analog code measured value can also be obtained by adding low-frequency phase-shifted fringe patterns. Then, the corrected absolute analog code measured value can be obtained by correcting the former by the latter, and the period jump errors can be eliminated, resulting in reliable analog code unwrapping. For the proposed approach, we established its measurement model, analyzed its measurement principle, expounded the mechanism of eliminating period jump errors by error analysis, and determined its applicable conditions. Theoretical analysis and experimental results show that the proposed approach can effectively eliminate period jump errors, reliably perform analog code unwrapping, and improve the measurement accuracy.

  19. Three frequency modulated combination thermal neutron lifetime log and porosity

    International Nuclear Information System (INIS)

    Paap, H.J.; Arnold, D.M.; Smith, M.P.

    1976-01-01

    Methods are disclosed for measuring simultaneously the thermal neutron lifetime of the borehole fluid and earth formations in the vicinity of a well borehole, together with the formation porosity. A harmonically intensity modulated source of fast neutrons is used to irradiate the earth formations with fast neutrons at three different modulation frequencies. Intensity modulated clouds of thermal neutrons at each of the three modulation frequencies are detected by dual spaced detectors and the relative phase shift of the thermal neutrons with respect to the fast neutrons is determined at each of the three modulation frequencies at each detector. These measurements are then combined to determine simultaneously the thermal neutron decay time of the borehole fluid, the thermal neutron decay time of surrounding earth formation media and the porosity of the formation media

  20. Combined effects of extremely high frequency electromagnetic field and antibiotics on Enterococcus Hirae growth and survival

    International Nuclear Information System (INIS)

    Ohanyan, V.A.

    2012-01-01

    Combined effects of extremely high frequency electromagnetic field and antibiotics on Enterococcus hirae ATCC 9790 bacterial growth and survival were investigated using 51.8 GHz and 53 GHz frequencies in combination with two commonly used antibiotics: ampicillin and dalacin. Results revealed that, despite bacterial type and membrane structure and properties, the combined effect, especially with 53 GHz and dalacin, suppresses bacterial growth and decreases their survival

  1. Improving Ambiguity Resolution for Medium Baselines Using Combined GPS and BDS Dual/Triple-Frequency Observations.

    Science.gov (United States)

    Gao, Wang; Gao, Chengfa; Pan, Shuguo; Wang, Denghui; Deng, Jiadong

    2015-10-30

    The regional constellation of the BeiDou navigation satellite system (BDS) has been providing continuous positioning, navigation and timing services since 27 December 2012, covering China and the surrounding area. Real-time kinematic (RTK) positioning with combined BDS and GPS observations is feasible. Besides, all satellites of BDS can transmit triple-frequency signals. Using the advantages of multi-pseudorange and carrier observations from multi-systems and multi-frequencies is expected to be of much benefit for ambiguity resolution (AR). We propose an integrated AR strategy for medium baselines by using the combined GPS and BDS dual/triple-frequency observations. In the method, firstly the extra-wide-lane (EWL) ambiguities of triple-frequency system, i.e., BDS, are determined first. Then the dual-frequency WL ambiguities of BDS and GPS were resolved with the geometry-based model by using the BDS ambiguity-fixed EWL observations. After that, basic (i.e., L1/L2 or B1/B2) ambiguities of BDS and GPS are estimated together with the so-called ionosphere-constrained model, where the ambiguity-fixed WL observations are added to enhance the model strength. During both of the WL and basic AR, a partial ambiguity fixing (PAF) strategy is adopted to weaken the negative influence of new-rising or low-elevation satellites. Experiments were conducted and presented, in which the GPS/BDS dual/triple-frequency data were collected in Nanjing and Zhengzhou of China, with the baseline distance varying from about 28.6 to 51.9 km. The results indicate that, compared to the single triple-frequency BDS system, the combined system can significantly enhance the AR model strength, and thus improve AR performance for medium baselines with a 75.7% reduction of initialization time on average. Besides, more accurate and stable positioning results can also be derived by using the combined GPS/BDS system.

  2. Simulation of a programmed frequency shift near extraction from the Fermilab Booster

    International Nuclear Information System (INIS)

    Lucas, P.; Kerns, Q.

    1987-03-01

    The longitudinal phase space program ESME has been used to simulate the effects of a linear shift in RF frequency away from that appropriate for the accelerator guide field. This shift takes place in the new Booster low level RF and is used to position the particle bunches in Main Ring buckets in a reproducible fashion. Shifts in frequency are found to generate synchrotron oscillations; however, the simulations show that these can be reduced to acceptable levels by introduction of jumps in RF phase preceding the programmed frequency changes. Lowering the RF voltage near extraction from the Booster, a desirable operational feature, has also been investigated

  3. Improved Intelligent Underlay-Overlay Combined with Frequency Hopping in GSM

    DEFF Research Database (Denmark)

    Wigard, Jeroen; Nielsen, Thomas Toftegaard; Mogensen, Preben Elgaard

    1997-01-01

    IUO (intelligent underlay-overlay) in a combination with random frequency hopping in GSM is analysed. Several improvements to the original IUO concept analysed in Nielsen et al. (1997) are introduced. With the improved IUO concept it is possible to load a network configuration consisting of 4...

  4. High-frequency combination coding-based steady-state visual evoked potential for brain computer interface

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Feng; Zhang, Xin; Xie, Jun; Li, Yeping; Han, Chengcheng; Lili, Li; Wang, Jing [School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Xu, Guang-Hua [School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710054 (China)

    2015-03-10

    This study presents a new steady-state visual evoked potential (SSVEP) paradigm for brain computer interface (BCI) systems. The goal of this study is to increase the number of targets using fewer stimulation high frequencies, with diminishing subject’s fatigue and reducing the risk of photosensitive epileptic seizures. The new paradigm is High-Frequency Combination Coding-Based High-Frequency Steady-State Visual Evoked Potential (HFCC-SSVEP).Firstly, we studied SSVEP high frequency(beyond 25 Hz)response of SSVEP, whose paradigm is presented on the LED. The SNR (Signal to Noise Ratio) of high frequency(beyond 40 Hz) response is very low, which is been unable to be distinguished through the traditional analysis method; Secondly we investigated the HFCC-SSVEP response (beyond 25 Hz) for 3 frequencies (25Hz, 33.33Hz, and 40Hz), HFCC-SSVEP produces n{sup n} with n high stimulation frequencies through Frequence Combination Code. Further, Animproved Hilbert-huang transform (IHHT)-based variable frequency EEG feature extraction method and a local spectrum extreme target identification algorithmare adopted to extract time-frequency feature of the proposed HFCC-SSVEP response.Linear predictions and fixed sifting (iterating) 10 time is used to overcome the shortage of end effect and stopping criterion,generalized zero-crossing (GZC) is used to compute the instantaneous frequency of the proposed SSVEP respondent signals, the improved HHT-based feature extraction method for the proposed SSVEP paradigm in this study increases recognition efficiency, so as to improve ITR and to increase the stability of the BCI system. what is more, SSVEPs evoked by high-frequency stimuli (beyond 25Hz) minimally diminish subject’s fatigue and prevent safety hazards linked to photo-induced epileptic seizures, So as to ensure the system efficiency and undamaging.This study tests three subjects in order to verify the feasibility of the proposed method.

  5. High-frequency combination coding-based steady-state visual evoked potential for brain computer interface

    International Nuclear Information System (INIS)

    Zhang, Feng; Zhang, Xin; Xie, Jun; Li, Yeping; Han, Chengcheng; Lili, Li; Wang, Jing; Xu, Guang-Hua

    2015-01-01

    This study presents a new steady-state visual evoked potential (SSVEP) paradigm for brain computer interface (BCI) systems. The goal of this study is to increase the number of targets using fewer stimulation high frequencies, with diminishing subject’s fatigue and reducing the risk of photosensitive epileptic seizures. The new paradigm is High-Frequency Combination Coding-Based High-Frequency Steady-State Visual Evoked Potential (HFCC-SSVEP).Firstly, we studied SSVEP high frequency(beyond 25 Hz)response of SSVEP, whose paradigm is presented on the LED. The SNR (Signal to Noise Ratio) of high frequency(beyond 40 Hz) response is very low, which is been unable to be distinguished through the traditional analysis method; Secondly we investigated the HFCC-SSVEP response (beyond 25 Hz) for 3 frequencies (25Hz, 33.33Hz, and 40Hz), HFCC-SSVEP produces n n with n high stimulation frequencies through Frequence Combination Code. Further, Animproved Hilbert-huang transform (IHHT)-based variable frequency EEG feature extraction method and a local spectrum extreme target identification algorithmare adopted to extract time-frequency feature of the proposed HFCC-SSVEP response.Linear predictions and fixed sifting (iterating) 10 time is used to overcome the shortage of end effect and stopping criterion,generalized zero-crossing (GZC) is used to compute the instantaneous frequency of the proposed SSVEP respondent signals, the improved HHT-based feature extraction method for the proposed SSVEP paradigm in this study increases recognition efficiency, so as to improve ITR and to increase the stability of the BCI system. what is more, SSVEPs evoked by high-frequency stimuli (beyond 25Hz) minimally diminish subject’s fatigue and prevent safety hazards linked to photo-induced epileptic seizures, So as to ensure the system efficiency and undamaging.This study tests three subjects in order to verify the feasibility of the proposed method

  6. Nonlinear oscillations of the FitzHugh-Nagumo equations under combined external and two-frequency parametric excitations

    International Nuclear Information System (INIS)

    Tatchim Bemmo, D.; Siewe Siewe, M.; Tchawoua, C.

    2011-01-01

    The continuous FitzHugh-Nagumo (FHN for short) model is transformed into modified van der Pol oscillator with asymmetry under external and two-frequency parametric excitations. At the first, the dependence of the solutions on a combined external and two-frequency parametric stimulus forcing is investigated. By using the multiple scale method, ranges of applied current and/or parametric forcing in which nonlinear oscillations are observed are described. Second, when the multiple scale method cannot be used, we numerically prove that in the modified van der Pol oscillator with asymmetry under external and two-frequency parametric excitations, chaos and periodic solution depending on the combination between different frequencies of the model should appear. We also show that the amplitude of the oscillations can be reduced or increased. To do this, we perform the study of the FHN model by choosing a range of parameters exhibiting Hopf bifurcation and two qualitative different regimes in phase portrait. - Highlights: → We model both external and two-frequency parametric excitations in FHN equations. → We examine effects of harmonic forcing on coupled nonlinear oscillator. → Jump and hysteresis phenomena are observed in the dynamical response. → By increasing the constant stimulus we obtain limit cycle. → Some combinations of frequencies produce limit cycle and chaos for other.

  7. Combining different frequencies for electrical heating of saturated and unsaturated soil zones

    Energy Technology Data Exchange (ETDEWEB)

    Roland, U.; Holzer, F.; Kopinke, F.D. [Helmholtz Centre for Environmental Research - UFZ, Department of Environmental Engineering, Leipzig (Germany)

    2011-10-15

    In situ electrical heating of soil was studied applying different frequencies: low-frequency energy for resistive heating and radio-frequency energy for dielectric heating. Steep temperature gradients were observed for each heating mode under the condition of the coexistence of saturated and unsaturated soil zones. By combining the two heating modes, this undesired effect can be avoided, thus allowing efficient soil remediation especially when organic phases are accumulated at the capillary fringe. A parallel application of both frequencies was demonstrated as the most suitable method to reduce temperature gradients. By using electronic filters, both electric fields can be established by only one electrode array. This innovative concept is especially applicable for optimizing thermal remediation of light non-aqueous phase liquid contaminations or realizing thermally-enhanced electrokinetic removal of heavy metals. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Comparison of skin sensory thresholds using pre-programmed or single-frequency transcutaneous electrical nerve stimulation.

    Science.gov (United States)

    Kang, Jong Ho

    2015-12-01

    [Purpose] The purpose of the present study was to compare the sensory thresholds of healthy subjects using pre-programmed or single-frequency transcutaneous electrical nerve stimulation. [Subjects] Ninety healthy adult subjects were randomly assigned to pre-programmed or single-frequency stimulation groups, each consisting of 45 participants. [Methods] Sensory thresholds were measured in the participants' forearms using von Frey filaments before and after pre-programmed or single-frequency transcutaneous electrical nerve stimulation, and the result in values were analyzed. [Results] Significant increases in sensory threshold after stimulation were observed in both groups. However, there were no significant differences between the two groups in sensory thresholds after stimulation or in the magnitude of threshold increases following stimulation. [Conclusion] Our results show that there are no differences between sensory threshold increases induced by pre-programmed and single-frequency transcutaneous electrical nerve stimulation.

  9. Frequency modulation television analysis: Threshold impulse analysis. [with computer program

    Science.gov (United States)

    Hodge, W. H.

    1973-01-01

    A computer program is developed to calculate the FM threshold impulse rates as a function of the carrier-to-noise ratio for a specified FM system. The system parameters and a vector of 1024 integers, representing the probability density of the modulating voltage, are required as input parameters. The computer program is utilized to calculate threshold impulse rates for twenty-four sets of measured probability data supplied by NASA and for sinusoidal and Gaussian modulating waveforms. As a result of the analysis several conclusions are drawn: (1) The use of preemphasis in an FM television system improves the threshold by reducing the impulse rate. (2) Sinusoidal modulation produces a total impulse rate which is a practical upper bound for the impulse rates of TV signals providing the same peak deviations. (3) As the moment of the FM spectrum about the center frequency of the predetection filter increases, the impulse rate tends to increase. (4) A spectrum having an expected frequency above (below) the center frequency of the predetection filter produces a higher negative (positive) than positive (negative) impulse rate.

  10. Overcomplete Blind Source Separation by Combining ICA and Binary Time-Frequency Masking

    DEFF Research Database (Denmark)

    Pedersen, Michael Syskind; Wang, DeLiang; Larsen, Jan

    2005-01-01

    a novel method for over-complete blind source separation. Two powerful source separation techniques have been combined, independent component analysis and binary time-frequency masking. Hereby, it is possible to iteratively extract each speech signal from the mixture. By using merely two microphones we...

  11. Combined Exposure to Dissimilarly Acting Anti-Androgens causes Markedly Increased Frequency of Hypospadias in the Rat

    DEFF Research Database (Denmark)

    Christiansen, Sofie; Petersen, Marta Axelstad; Scholze, Martin

    2007-01-01

    , a combination of doses of each chemical that on its own did not produce clear sign of hypospadias (DEHP, finasteride and prochloraz) or a frequency around 14% (vinclozolin) induced a 100% frequency of hypospadias. In conclusion, doses of anti-androgens, which appear to induce only low frequencies of hypospadias...... when judged on their own, may induce a very high frequency when they interact in concert with other anti-androgens....

  12. Fast frequency divider circuit using combinational logic

    Science.gov (United States)

    Helinski, Ryan

    2017-05-30

    The various technologies presented herein relate to performing on-chip frequency division of an operating frequency of a ring oscillator (RO). Per the various embodiments herein, a conflict between RO size versus operational frequency can be addressed by dividing the output frequency of the RO to a frequency that can be measured on-chip. A frequency divider circuit (comprising NOR gates and latches, for example) can be utilized in conjunction with the RO on the chip. In an embodiment, the frequency divider circuit can include a pair of latches coupled to the RO to facilitate dividing the oscillating frequency of the RO by 2. In another embodiment, the frequency divider circuit can include four latches (operating in pairs) coupled to the RO to facilitate dividing the oscillating frequency of the RO by 4. A plurality of ROs can be MUXed to the plurality of ROs by a single oscillation-counting circuit.

  13. Continuous exposure to low-frequency noise and carbon disulfide: Combined effects on hearing.

    Science.gov (United States)

    Venet, Thomas; Carreres-Pons, Maria; Chalansonnet, Monique; Thomas, Aurélie; Merlen, Lise; Nunge, Hervé; Bonfanti, Elodie; Cosnier, Frédéric; Llorens, Jordi; Campo, Pierre

    2017-09-01

    Carbon disulfide (CS 2 ) is used in industry; it has been shown to have neurotoxic effects, causing central and distal axonopathies.However, it is not considered cochleotoxic as it does not affect hair cells in the organ of Corti, and the only auditory effects reported in the literature were confined to the low-frequency region. No reports on the effects of combined exposure to low-frequency noise and CS 2 have been published to date. This article focuses on the effects on rat hearing of combined exposure to noise with increasing concentrations of CS 2 (0, 63,250, and 500ppm, 6h per day, 5 days per week, for 4 weeks). The noise used was a low-frequency noise ranging from 0.5 to 2kHz at an intensity of 106dB SPL. Auditory function was tested using distortion product oto-acoustic emissions, which mainly reflects the cochlear performances. Exposure to noise alone caused an auditory deficit in a frequency area ranging from 3.6 to 6 kHz. The damaged area was approximately one octave (6kHz) above the highest frequency of the exposure noise (2.8kHz); it was a little wider than expected based on the noise spectrum.Consequently, since maximum hearing sensitivity is located around 8kHz in rats, low-frequency noise exposure can affect the cochlear regions detecting mid-range frequencies. Co-exposure to CS 2 (250-ppm and over) and noise increased the extent of the damaged frequency window since a significant auditory deficit was measured at 9.6kHz in these conditions.Moreover, the significance at 9.6kHz increased with the solvent concentrations. Histological data showed that neither hair cells nor ganglion cells were damaged by CS 2 . This discrepancy between functional and histological data is discussed. Like most aromatic solvents, carbon disulfide should be considered as a key parameter in hearing conservation régulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. The index-flood and the GRADEX methods combination for flood frequency analysis.

    Science.gov (United States)

    Fuentes, Diana; Di Baldassarre, Giuliano; Quesada, Beatriz; Xu, Chong-Yu; Halldin, Sven; Beven, Keith

    2017-04-01

    Flood frequency analysis is used in many applications, including flood risk management, design of hydraulic structures, and urban planning. However, such analysis requires of long series of observed discharge data which are often not available in many basins around the world. In this study, we tested the usefulness of combining regional discharge and local precipitation data to estimate the event flood volume frequency curve for 63 catchments in Mexico, Central America and the Caribbean. This was achieved by combining two existing flood frequency analysis methods, the regionalization index-flood approach with the GRADEX method. For up to 10-years return period, similar shape of the scaled flood frequency curve for catchments with similar flood behaviour was assumed from the index-flood approach. For return periods larger than 10-years the probability distribution of rainfall and discharge volumes were assumed to be asymptotically and exponential-type functions with the same scale parameter from the GRADEX method. Results showed that if the mean annual flood (MAF), used as index-flood, is known, the index-flood approach performed well for up to 10 years return periods, resulting in 25% mean relative error in prediction. For larger return periods the prediction capability decreased but could be improved by the use of the GRADEX method. As the MAF is unknown at ungauged and short-period measured basins, we tested predicting the MAF using catchments climate-physical characteristics, and discharge statistics, the latter when observations were available for only 8 years. Only the use of discharge statistics resulted in acceptable predictions.

  15. Orientations of nonlocal vibrational modes from combined experimental and theoretical sum frequency spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chase, Hilary M.; Chen, Shunli; Fu, Li; Upshur, Mary Alice; Rudshteyn, Benjamin; Thomson, Regan J.; Wang, Hong-Fei; Batista, Victor S.; Geiger, Franz M.

    2017-09-01

    Inferring molecular orientations from vibrational sum frequency generation (SFG) spectra is challenging in polarization combinations that result in low signal intensities, or when the local point group symmetry approximation fails. While combining experiments with density functional theory (DFT) could overcome this problem, the scope of the combined method has yet to be established. Here, we assess its feasibility of determining the distributions of molecular orientations for one monobasic ester, two epoxides and three alcohols at the vapor/fused silica interface. We find that molecular orientations of nonlocal vibrational modes cannot be determined using polarization-resolved SFG measurements alone.

  16. Study on the usefulness of high-frequency analysis of the combined treatment of cancer with hyperthermia

    International Nuclear Information System (INIS)

    Ji, Youn Sang; Dong, Kyung Rae; Yeo, Hwa Yeon

    2016-01-01

    In order to understand the usefulness to the high-frequency thermal therapy of cancer staging according to the TNM classification treatment, was to evaluate the effect of high frequency hyperthermia treatment approach through other means and whether other organs, according to the combined presence of transition. Targeted to receive more than a total of 1 cycle high frequency heat treatment at C hospital that performed the high-frequency hyperthermia cancer patients 92 people out stage, depending on the presence or absence of metastasis, combined hyperthermia patients for statistics before and after treatment the therapeutic effect of the therapeutic classification. Out of a total of 92 patients decrease 11 patients, stable 71 patients, with increase 10 patients, the rate of increase is the result of about 11% patients showed a decrease of about 89% is occupied by patients and a stable rate. There is strong evidence for the usefulness as a secondary therapy to maintain the quality of life, while slowing the progression of cancer by a high-frequency heat treatment

  17. Study on the usefulness of high-frequency analysis of the combined treatment of cancer with hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Youn Sang; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Yeo, Hwa Yeon [Dept. of of Radiology, Nambu University, Gwangju (Korea, Republic of)

    2016-11-15

    In order to understand the usefulness to the high-frequency thermal therapy of cancer staging according to the TNM classification treatment, was to evaluate the effect of high frequency hyperthermia treatment approach through other means and whether other organs, according to the combined presence of transition. Targeted to receive more than a total of 1 cycle high frequency heat treatment at C hospital that performed the high-frequency hyperthermia cancer patients 92 people out stage, depending on the presence or absence of metastasis, combined hyperthermia patients for statistics before and after treatment the therapeutic effect of the therapeutic classification. Out of a total of 92 patients decrease 11 patients, stable 71 patients, with increase 10 patients, the rate of increase is the result of about 11% patients showed a decrease of about 89% is occupied by patients and a stable rate. There is strong evidence for the usefulness as a secondary therapy to maintain the quality of life, while slowing the progression of cancer by a high-frequency heat treatment.

  18. On the complexity of a combined homotopy interior method for convex programming

    Science.gov (United States)

    Yu, Bo; Xu, Qing; Feng, Guochen

    2007-03-01

    In [G.C. Feng, Z.H. Lin, B. Yu, Existence of an interior pathway to a Karush-Kuhn-Tucker point of a nonconvex programming problem, Nonlinear Anal. 32 (1998) 761-768; G.C. Feng, B. Yu, Combined homotopy interior point method for nonlinear programming problems, in: H. Fujita, M. Yamaguti (Eds.), Advances in Numerical Mathematics, Proceedings of the Second Japan-China Seminar on Numerical Mathematics, Lecture Notes in Numerical and Applied Analysis, vol. 14, Kinokuniya, Tokyo, 1995, pp. 9-16; Z.H. Lin, B. Yu, G.C. Feng, A combined homotopy interior point method for convex programming problem, Appl. Math. Comput. 84 (1997) 193-211.], a combined homotopy was constructed for solving non-convex programming and convex programming with weaker conditions, without assuming the logarithmic barrier function to be strictly convex and the solution set to be bounded. It was proven that a smooth interior path from an interior point of the feasible set to a K-K-T point of the problem exists. This shows that combined homotopy interior point methods can solve the problem that commonly used interior point methods cannot solveE However, so far, there is no result on its complexity, even for linear programming. The main difficulty is that the objective function is not monotonically decreasing on the combined homotopy path. In this paper, by taking a piecewise technique, under commonly used conditions, polynomiality of a combined homotopy interior point method is given for convex nonlinear programming.

  19. A Frequency-Tracking and Impedance-Matching Combined System for Robust Wireless Power Transfer

    Directory of Open Access Journals (Sweden)

    Yanting Luo

    2017-01-01

    Full Text Available One of the greatest challenges to power embedded devices using magnetically coupled resonant wireless power transfer (WPT system is that the amount of power delivered to the load is very sensitive to load impedance variations. Previous adaptive impedance-matching (IM technologies have drawbacks because adding IM networks, relay coils, or other compensating components in the receiver-side will significantly increase the receiver size. In this paper, a novel frequency-tracking and impedance-matching combined system is proposed to improve the robustness of wireless power transfer for embedded devices. The characteristics of the improved WPT system are investigated theoretically based on the two-port network model. Simulation and experimental studies are carried out to validate the proposed system. The results suggest that the frequency-tracking and impedance-matching combined WPT system can quickly find the best matching points and maintain high power transmission efficiency and output power when the load impedance changes.

  20. CiOpt: a program for optimization of the frequency response of linear circuits

    OpenAIRE

    Miró Sans, Joan Maria; Palà Schönwälder, Pere

    1991-01-01

    An interactive personal-computer program for optimizing the frequency response of linear lumped circuits (CiOpt) is presented. CiOpt has proved to be an efficient tool in improving designs where the inclusion of more accurate device models distorts the desired frequency response, as well as in device modeling. The outputs of CiOpt are the element values which best match the obtained and the desired frequency response. The optimization algorithms used (the Fletcher-Powell and Newton's methods,...

  1. A general purpose tomographic program with combined inversions

    International Nuclear Information System (INIS)

    Xu Wenbin; Dong Jiafu; Li Fanzhu

    1996-01-01

    A general tomographic program has been developed by combining the Bessel expansion with the Zernicke expansion. It is useful for studying of the magnetic island structure of the tearing mode and in reconstructing the density profiles of impurities in tokamak plasmas. This combined method have the advantages of both expansions, i.e. there will be no spurious images in the edge and it will be of high inverse precision in the center of plasma

  2. Frequency Selective Properties of Coaxial Transmission Lines Loaded with Combined Artificial Inclusions

    Directory of Open Access Journals (Sweden)

    Francisco Falcone

    2014-01-01

    Full Text Available The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology.

  3. Frequency of injuries, in particular dental injuries, in ski jumping and Nordic combined.

    Science.gov (United States)

    Stillhard, Angela; Buschor, Cornel; Krastl, Gabriel; Kühl, Sebastian; Filippi, Andreas

    This study investigates the frequency of injuries, in particular dental injuries, among ski jumpers and Nordic combined athletes. It also examines the level of knowledge regarding tooth protection and tooth rescue boxes in this population. Of the 465 sportswomen and sportsmen who took part in the study, 230 (62.5%) of the 368 ski jumpers and 56 (56.5%) of the 97 Nordic combined athletes had sustained an injury. In both disciplines injury was most likely among professionals. The survey participants reported injuries to the limbs (n = 216), head and lips (n = 273 and n = 253, respectively), torso or spine (n = 249), teeth (n = 246), nose (n = 229) and jaw (n = 26). Dental injuries were more common among professionals than either amateur or junior ski jumpers, whereas, among the Nordic combined athletes, juniors were most likely to sustain a dental injury. Overall, the frequency of dental injury was significantly (p = 0.019) higher among adults 12.7% (n = 234) than junior athletes 6.1% (n = 212). The level of awareness of mouthguards and tooth rescue boxes varied between countries. The high injury rate recorded in this study demonstrates that ski jumping contains a considerable risk of injury, including tooth damage. Consequently, it seems reasonable to inform skiing organisations, trainers and athletes about the potential benefits of mouthguards and tooth rescue boxes in order to reduce the risk of dental injury.

  4. Probing phase- and frequency-dependent characteristics of cortical interneurons using combined transcranial alternating current stimulation and transcranial magnetic stimulation.

    Science.gov (United States)

    Hussain, Sara J; Thirugnanasambandam, Nivethida

    2017-06-01

    Paired-pulse transcranial magnetic stimulation (TMS) and peripheral stimulation combined with TMS can be used to study cortical interneuronal circuitry. By combining these procedures with concurrent transcranial alternating current stimulation (tACS), Guerra and colleagues recently showed that different cortical interneuronal populations are differentially modulated by the phase and frequency of tACS-imposed oscillations (Guerra A, Pogosyan A, Nowak M, Tan H, Ferreri F, Di Lazzaro V, Brown P. Cerebral Cortex 26: 3977-2990, 2016). This work suggests that different cortical interneuronal populations can be characterized by their phase and frequency dependency. Here we discuss how combining TMS and tACS can reveal the frequency at which cortical interneuronal populations oscillate, the neuronal origins of behaviorally relevant cortical oscillations, and how entraining cortical oscillations could potentially treat brain disorders. Copyright © 2017 the American Physiological Society.

  5. High-frequency volatility combine forecast evaluations: An empirical study for DAX

    Directory of Open Access Journals (Sweden)

    Wen Cheong Chin

    2017-01-01

    Full Text Available This study aims to examine the benefits of combining realized volatility, higher power variation volatility and nearest neighbour truncation volatility in the forecasts of financial stock market of DAX. A structural break heavy-tailed heterogeneous autoregressive model under the heterogeneous market hypothesis specification is employed to capture the stylized facts of high-frequency empirical data. Using selected averaging forecast methods, the forecast weights are assigned based on the simple average, simple median, least squares and mean square error. The empirical results indicated that the combination of forecasts in general shown superiority under four evaluation criteria regardless which proxy is set as the actual volatility. As a conclusion, we summarized that the forecast performance is influenced by three factors namely the types of volatility proxy, forecast methods (individual or averaging forecast and lastly the type of actual forecast value used in the evaluation criteria.

  6. Introduction of a school fruit program is associated with reduced frequency of consumption of unhealthy snacks.

    Science.gov (United States)

    Øverby, Nina Cecilie; Klepp, Knut-Inge; Bere, Elling

    2012-11-01

    A diet high in fruit and vegetables (FV) is inversely related to chronic diseases, and some studies suggest that increasing the intake of FV reduces the intake of unhealthy snacks. The objectives were to analyze changes in the frequency of consumption of unhealthy snacks (soda, candy, and potato chips) from 2001 to 2008 in Norwegian children, to assess whether being part of a school fruit program reduces the frequency of unhealthy snack consumption, and to explore differences in sex and socioeconomic status. Within the project Fruits and Vegetables Make the Marks, 1488 sixth- and seventh-grade pupils from 27 Norwegian elementary schools completed a questionnaire in 2001, and 1339 sixth- and seventh-grade pupils from the same schools completed the same questionnaire in 2008. In 2001, none of the schools had any organized school fruit program. In 2008, 15 schools participated in a program and 12 did not participate in any program. From 2001 to 2008, the frequency of unhealthy snack consumption decreased from 6.9 to 4.6 times/wk (P snack consumption in children of parents without higher education (from 7.8 to 4.0 times/wk; P = 0.004). The frequency of unhealthy snack consumption decreased from 2001 to 2008 in schoolchildren in Norway. The decrease was most evident among children at schools participating in the national free school fruit program and in children with a low socioeconomic status.

  7. Cross Time-Frequency Analysis for Combining Information of Several Sources: Application to Estimation of Spontaneous Respiratory Rate from Photoplethysmography

    Science.gov (United States)

    Peláez-Coca, M. D.; Orini, M.; Lázaro, J.; Bailón, R.; Gil, E.

    2013-01-01

    A methodology that combines information from several nonstationary biological signals is presented. This methodology is based on time-frequency coherence, that quantifies the similarity of two signals in the time-frequency domain. A cross time-frequency analysis method, based on quadratic time-frequency distribution, has been used for combining information of several nonstationary biomedical signals. In order to evaluate this methodology, the respiratory rate from the photoplethysmographic (PPG) signal is estimated. The respiration provokes simultaneous changes in the pulse interval, amplitude, and width of the PPG signal. This suggests that the combination of information from these sources will improve the accuracy of the estimation of the respiratory rate. Another target of this paper is to implement an algorithm which provides a robust estimation. Therefore, respiratory rate was estimated only in those intervals where the features extracted from the PPG signals are linearly coupled. In 38 spontaneous breathing subjects, among which 7 were characterized by a respiratory rate lower than 0.15 Hz, this methodology provided accurate estimates, with the median error {0.00; 0.98} mHz ({0.00; 0.31}%) and the interquartile range error {4.88; 6.59} mHz ({1.60; 1.92}%). The estimation error of the presented methodology was largely lower than the estimation error obtained without combining different PPG features related to respiration. PMID:24363777

  8. Cross Time-Frequency Analysis for Combining Information of Several Sources: Application to Estimation of Spontaneous Respiratory Rate from Photoplethysmography

    Directory of Open Access Journals (Sweden)

    M. D. Peláez-Coca

    2013-01-01

    Full Text Available A methodology that combines information from several nonstationary biological signals is presented. This methodology is based on time-frequency coherence, that quantifies the similarity of two signals in the time-frequency domain. A cross time-frequency analysis method, based on quadratic time-frequency distribution, has been used for combining information of several nonstationary biomedical signals. In order to evaluate this methodology, the respiratory rate from the photoplethysmographic (PPG signal is estimated. The respiration provokes simultaneous changes in the pulse interval, amplitude, and width of the PPG signal. This suggests that the combination of information from these sources will improve the accuracy of the estimation of the respiratory rate. Another target of this paper is to implement an algorithm which provides a robust estimation. Therefore, respiratory rate was estimated only in those intervals where the features extracted from the PPG signals are linearly coupled. In 38 spontaneous breathing subjects, among which 7 were characterized by a respiratory rate lower than 0.15 Hz, this methodology provided accurate estimates, with the median error {0.00; 0.98} mHz ({0.00; 0.31}% and the interquartile range error {4.88; 6.59} mHz ({1.60; 1.92}%. The estimation error of the presented methodology was largely lower than the estimation error obtained without combining different PPG features related to respiration.

  9. Induction heating of gears - pulsing dual-frequency concept

    Directory of Open Access Journals (Sweden)

    R. Przyłucki

    2013-04-01

    Full Text Available The paper concerns analysis of gears hardening process. In order to obtain required temperature distribution several variations of single and combined frequencies for selected gear-wheel configurations were considered. The paper includes the calculation models and analysis of geometry and current intensity as well frequency influence on temperature distribution of the tooth surface. All calculations have been carried out by means of the use of Flux3D simulation program, which enables to provide, coupled electromagnetic and temperature fields analysis.

  10. Wound healing treatment by high frequency ultrasound, microcurrent, and combined therapy modifies the immune response in rats

    Directory of Open Access Journals (Sweden)

    Raciele I. G. Korelo

    2016-01-01

    Full Text Available BACKGROUND: Therapeutic high-frequency ultrasound, microcurrent, and a combination of the two have been used as potential interventions in the soft tissue healing process, but little is known about their effect on the immune system. OBJECTIVE: To evaluate the effects of therapeutic high frequency ultrasound, microcurrent, and the combined therapy of the two on the size of the wound area, peritoneal macrophage function, CD4+ and CD8+, T lymphocyte populations, and plasma concentration of interleukins (ILs. METHOD: Sixty-five Wistar rats were randomized into five groups, as follows: uninjured control (C, group 1, lesion and no treatment (L, group 2, lesion treated with ultrasound (LU, group 3, lesion treated with microcurrent (LM, group 4, and lesion treated with combined therapy (LUM, group 5. For groups 3, 4 and 5, treatment was initiated 24 hours after surgery under anesthesia and each group was allocated into three different subgroups (n=5 to allow for the use of the different therapy resources at on days 3, 7 and 14 Photoplanimetry was performed daily. After euthanasia, blood was collected for immune analysis. RESULTS: Ultrasound increased the phagocytic capacity and the production of nitric oxide by macrophages and induced the reduction of CD4+ cells, the CD4+/CD8+ ratio, and the plasma concentration of IL-1β. Microcurrent and combined therapy decreased the production of superoxide anion, nitric oxide, CD4+-positive cells, the CD4+/CD8+ ratio, and IL-1β concentration. CONCLUSIONS: Therapeutic high-frequency ultrasound, microcurrent, and combined therapy changed the activity of the innate and adaptive immune system during healing process but did not accelerate the closure of the wound.

  11. Studies on induced mutation frequency in Catharanthus roseus (L.) G. Don by gamma rays and EMS individually and in combination

    International Nuclear Information System (INIS)

    Venkateswarlu, M.; Susheelamma, B.N.; Kumar, P.; Subhash, K.

    1988-01-01

    Seeds of pink flowered (PF) and white flowered (WF) Catharanthus roseus were soaked in distilled water for 24 h and treated with gamma rays and 0.1% EMS separately and in combination. Six types of chlorophyll mutations, viz., xantha, albina, chlorina, viridis, maculata and tigrina were recovered to M 2 generation of both forms. The frequency of chlorophyll mutations was found to be dependent on the dose, of gamma rays and duration of treatment with EMS. Higher frequency of chlorophyll mutations was noticed in PF, which is mutagenically more sensitive than WF. It was also noticed that the combination treatments of gamma rays and EMS enhanced the frequency of chlorophyll mutations

  12. TITAN: a computer program for accident occurrence frequency analyses by component Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Nomura, Yasushi [Department of Fuel Cycle Safety Research, Nuclear Safety Research Center, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan); Tamaki, Hitoshi [Department of Safety Research Technical Support, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan); Kanai, Shigeru [Fuji Research Institute Corporation, Tokyo (Japan)

    2000-04-01

    In a plant system consisting of complex equipments and components for a reprocessing facility, there might be grace time between an initiating event and a resultant serious accident, allowing operating personnel to take remedial actions, thus, terminating the ongoing accident sequence. A component Monte Carlo simulation computer program TITAN has been developed to analyze such a complex reliability model including the grace time without any difficulty to obtain an accident occurrence frequency. Firstly, basic methods for the component Monte Carlo simulation is introduced to obtain an accident occurrence frequency, and then, the basic performance such as precision, convergence, and parallelization of calculation, is shown through calculation of a prototype accident sequence model. As an example to illustrate applicability to a real scale plant model, a red oil explosion in a German reprocessing plant model is simulated to show that TITAN can give an accident occurrence frequency with relatively good accuracy. Moreover, results of uncertainty analyses by TITAN are rendered to show another performance, and a proposal is made for introducing of a new input-data format to adapt the component Monte Carlo simulation. The present paper describes the calculational method, performance, applicability to a real scale, and new proposal for the TITAN code. In the Appendixes, a conventional analytical method is shown to avoid complex and laborious calculation to obtain a strict solution of accident occurrence frequency, compared with Monte Carlo method. The user's manual and the list/structure of program are also contained in the Appendixes to facilitate TITAN computer program usage. (author)

  13. TITAN: a computer program for accident occurrence frequency analyses by component Monte Carlo simulation

    International Nuclear Information System (INIS)

    Nomura, Yasushi; Tamaki, Hitoshi; Kanai, Shigeru

    2000-04-01

    In a plant system consisting of complex equipments and components for a reprocessing facility, there might be grace time between an initiating event and a resultant serious accident, allowing operating personnel to take remedial actions, thus, terminating the ongoing accident sequence. A component Monte Carlo simulation computer program TITAN has been developed to analyze such a complex reliability model including the grace time without any difficulty to obtain an accident occurrence frequency. Firstly, basic methods for the component Monte Carlo simulation is introduced to obtain an accident occurrence frequency, and then, the basic performance such as precision, convergence, and parallelization of calculation, is shown through calculation of a prototype accident sequence model. As an example to illustrate applicability to a real scale plant model, a red oil explosion in a German reprocessing plant model is simulated to show that TITAN can give an accident occurrence frequency with relatively good accuracy. Moreover, results of uncertainty analyses by TITAN are rendered to show another performance, and a proposal is made for introducing of a new input-data format to adapt the component Monte Carlo simulation. The present paper describes the calculational method, performance, applicability to a real scale, and new proposal for the TITAN code. In the Appendixes, a conventional analytical method is shown to avoid complex and laborious calculation to obtain a strict solution of accident occurrence frequency, compared with Monte Carlo method. The user's manual and the list/structure of program are also contained in the Appendixes to facilitate TITAN computer program usage. (author)

  14. Frequency Domain Computer Programs for Prediction and Analysis of Rail Vehicle Dynamics : Volume 1. Technical Report

    Science.gov (United States)

    1975-12-01

    Frequency domain computer programs developed or acquired by TSC for the analysis of rail vehicle dynamics are described in two volumes. Volume I defines the general analytical capabilities required for computer programs applicable to single rail vehi...

  15. Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection.

    Science.gov (United States)

    Mwanza, Jean-Claude; Warren, Joshua L; Hochberg, Jessica T; Budenz, Donald L; Chang, Robert T; Ramulu, Pradeep Y

    2015-01-01

    To determine the ability of frequency doubling technology (FDT) and scanning laser polarimetry with variable corneal compensation (GDx-VCC) to detect glaucoma when used individually and in combination. One hundred ten normal and 114 glaucomatous subjects were tested with FDT C-20-5 screening protocol and the GDx-VCC. The discriminating ability was tested for each device individually and for both devices combined using GDx-NFI, GDx-TSNIT, number of missed points of FDT, and normal or abnormal FDT. Measures of discrimination included sensitivity, specificity, area under the curve (AUC), Akaike's information criterion (AIC), and prediction confidence interval lengths. For detecting glaucoma regardless of severity, the multivariable model resulting from the combination of GDx-TSNIT, number of abnormal points on FDT (NAP-FDT), and the interaction GDx-TSNIT×NAP-FDT (AIC: 88.28, AUC: 0.959, sensitivity: 94.6%, specificity: 89.5%) outperformed the best single-variable model provided by GDx-NFI (AIC: 120.88, AUC: 0.914, sensitivity: 87.8%, specificity: 84.2%). The multivariable model combining GDx-TSNIT, NAP-FDT, and interaction GDx-TSNIT×NAP-FDT consistently provided better discriminating abilities for detecting early, moderate, and severe glaucoma than the best single-variable models. The multivariable model including GDx-TSNIT, NAP-FDT, and the interaction GDx-TSNIT×NAP-FDT provides the best glaucoma prediction compared with all other multivariable and univariable models. Combining the FDT C-20-5 screening protocol and GDx-VCC improves glaucoma detection compared with using GDx or FDT alone.

  16. Extended-bandwidth frequency sweeps of a distributed feedback laser using combined injection current and temperature modulation.

    Science.gov (United States)

    Hefferman, Gerald; Chen, Zhen; Wei, Tao

    2017-07-01

    This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.

  17. Extended-bandwidth frequency sweeps of a distributed feedback laser using combined injection current and temperature modulation

    Science.gov (United States)

    Hefferman, Gerald; Chen, Zhen; Wei, Tao

    2017-07-01

    This article details the generation of an extended-bandwidth frequency sweep using a single, communication grade distributed feedback (DFB) laser. The frequency sweep is generated using a two-step technique. In the first step, injection current modulation is employed as a means of varying the output frequency of a DFB laser over a bandwidth of 99.26 GHz. A digital optical phase lock loop is used to lock the frequency sweep speed during current modulation, resulting in a linear frequency chirp. In the second step, the temperature of the DFB laser is modulated, resulting in a shifted starting laser output frequency. A laser frequency chirp is again generated beginning at this shifted starting frequency, resulting in a frequency-shifted spectrum relative to the first recorded data. This process is then repeated across a range of starting temperatures, resulting in a series of partially overlapping, frequency-shifted spectra. These spectra are then aligned using cross-correlation and combined using averaging to form a single, broadband spectrum with a total bandwidth of 510.9 GHz. In order to investigate the utility of this technique, experimental testing was performed in which the approach was used as the swept-frequency source of a coherent optical frequency domain reflectometry system. This system was used to interrogate an optical fiber containing a 20 point, 1-mm pitch length fiber Bragg grating, corresponding to a period of 100 GHz. Using this technique, both the periodicity of the grating in the frequency domain and the individual reflector elements of the structure in the time domain were resolved, demonstrating the technique's potential as a method of extending the sweeping bandwidth of semiconductor lasers for frequency-based sensing applications.

  18. Combining landscape-level conservation planning and biodiversity offset programs: a case study.

    Science.gov (United States)

    Underwood, Jared G

    2011-01-01

    Habitat loss is a major factor in the endangerment and extinction of species around the world. One promising strategy to balance continued habitat loss and biodiversity conservation is that of biodiversity offsets. However, a major concern with offset programs is their consistency with landscape-level conservation goals. While merging offset policies and landscape-level conservation planning is thought to provide advantages over a traditional disconnected approach, few such landscape-level conservation-offset plans have been designed and implemented, so the effectiveness of such a strategy remains uncertain. In this study, we quantitatively assess the conservation impact of combining landscape-level conservation planning and biodiversity offset programs by comparing regions of San Diego County, USA with the combined approach to regions with only an offset program. This comparison is generally very difficult due to a variety of complicating factors. We overcome these complications and quantify the benefits to rare and threatened species of implementing a combined approach by assessing the amount of each species' predicted distribution, and the number of documented locations, conserved in comparison to the same metric for areas with an offset policy alone. We found that adoption of the combined approach has increased conservation for many rare species, often 5-10 times more than in the comparison area, and that conservation has been focused in the areas most important for these species. The level of conservation achieved reduces uncertainty that these species will persist in the region into the future. This San Diego County example demonstrates the potential benefits of combining landscape-level conservation planning and biodiversity offset programs.

  19. Combining Primary Prevention and Risk Reduction Approaches in Sexual Assault Protection Programming

    Science.gov (United States)

    Menning, Chadwick; Holtzman, Mellisa

    2015-01-01

    Objective: The object of this study is to extend prior evaluations of Elemental, a sexual assault protection program that combines primary prevention and risk reduction strategies within a single program. Participants and Methods: During 2012 and 2013, program group and control group students completed pretest, posttest, and 6-week and 6-month…

  20. Climate change impacts on the duration and frequency of combined sewer overflows

    Science.gov (United States)

    Fortier, C.; Mailhot, A.

    2012-12-01

    Combined sewer overflows (CSO) occur when large rainwater inflow from heavy precipitation exceeds the capacity of urban combined sewage systems. Many American and European cities with old sewage systems see their water quality significantly deteriorate during such events. In the long term, changes in the rainfall regime due to climate change may lead to more severe and more frequent CSO episodes and thus compel cities to review their global water management. The overall objective of this study is to investigate how climate change will impact CSO frequency and duration. Data from rain gauges located nearby 30 overflow outfalls, in southern Quebec, Canada, were used to identify rain events leading to overflows, using CSO monitored data from May to October during the period 2007-2009. For each site, occurrence and duration of CSO events were recorded and linked to a rainfall event. Many rain events features can be used to predict CSO events, such as total depth, duration, average intensity and peak intensity. Results based on Pearson product-moment correlation coefficients and multiple regression analysis show that CSO occurrence is best predicted by total rainfall. A methodology is proposed to calculate the CSO probability of occurrence and duration for each site of interest using rainfall series as input data. Monte Carlo method is then used to estimate CSO frequency. To evaluate the climate change impact on CSO, these relationships are used with simulated data from the Canadian Regional Climate Model to compare the distribution of annual number of CSO events over the 1960-1990 period and the 2070-2100 period.

  1. The frequency of Tay-Sachs disease causing mutations in the Brazilian Jewish population justifies a carrier screening program.

    Science.gov (United States)

    Rozenberg, R; Pereira, L da V

    2001-07-05

    Tay-Sachs disease is an autosomal recessive disease characterized by progressive neurologic degeneration, fatal in early childhood. In the Ashkenazi Jewish population the disease incidence is about 1 in every 3,500 newborns and the carrier frequency is 1 in every 29 individuals. Carrier screening programs for Tay-Sachs disease have reduced disease incidence by 90% in high-risk populations in several countries. The Brazilian Jewish population is estimated at 90,000 individuals. Currently, there is no screening program for Tay-Sachs disease in this population. To evaluate the importance of a Tay-Sachs disease carrier screening program in the Brazilian Jewish population by determining the frequency of heterozygotes and the acceptance of the program by the community. Laboratory of Molecular Genetics--Institute of Biosciences--Universidade de São Paulo. 581 senior students from selected Jewish high schools. Molecular analysis of Tay-Sachs disease causing mutations by PCR amplification of genomic DNA, followed by restriction enzyme digestion. Among 581 students that attended educational classes, 404 (70%) elected to be tested for Tay-Sachs disease mutations. Of these, approximately 65% were of Ashkenazi Jewish origin. Eight carriers were detected corresponding to a carrier frequency of 1 in every 33 individuals in the Ashkenazi Jewish fraction of the sample. The frequency of Tay-Sachs disease carriers among the Ashkenazi Jewish population of Brazil is similar to that of other countries where carrier screening programs have led to a significant decrease in disease incidence. Therefore, it is justifiable to implement a Tay-Sachs disease carrier screening program for the Brazilian Jewish population.

  2. Simultaneous rotational and vibrational CARS generation through a multiple-frequency combination technique

    International Nuclear Information System (INIS)

    Alden, M.; Bengtsson, P.E.; Edner, H.

    1987-01-01

    One most promising laser technique for probing combustion processes is coherent anti-Stokes Raman scattering (CARS), which due to its coherent nature and signal strength is applied in several real-world applications. Until today almost all CARS experiments are based on probing the population of molecular vibrational energy levels. However, there are several reasons rotational CARS, i.e. probing of rotational energy levels, may provide a complement to or even a better choice than vibrational CARS. Recently an alternative way to produce rotational CARS spectra is proposed, which is based on a multiple-frequency combination technique. The energy-level diagram for this process is presented. Two dye laser beams at ω/sub r/, and one fix frequency laser beam at ω/sub g/ are employed. ω/sub r,1/ and ω/sub r,2/ are two frequencies of many possible pairs with a frequency difference matching a rotational transition in a molecule. The excitation induced by ω/sub r,1/ and ω/sub r,2/ is then scattered by the narrowband ω/sub g/ beam resulting in a CARS beam ω/sub g/ at ω/sub g/ + ω/sub r,1/ - ω/sub r,2/. An interesting feature with this technique is that it is possible to generate simultaneously a rotational and vibrational CARS spectrum by using a double-folded boxcars phase matching approach. The authors believe that the proposed technique for producing rotational and vibration CARS spectra could be of interest, e.g., when measuring in highly turbulent flows. In this case the rotational CARS spectra could use for temperature measurements in the cooler parts, whereas vibrational CARS are to be preferred when measuring in the hotter parts

  3. Solving the Frequency Assignment Problem by Site Availability and Constraint Programming

    OpenAIRE

    Linhares, Andrea Carneiro; Torres-Moreno, Juan-Manuel; Peinl, Peter; Michelon, Philippe

    2010-01-01

    The efficient use of bandwidth for radio communications becomes more and more crucial when developing new information technologies and their applications. The core issues are addressed by the so-called Frequency Assignment Problems (FAP). Our work investigates static FAP, where an attempt is first made to configure a kernel of links. We study the problem based on the concepts and techniques of Constraint Programming and integrate the site availability concept. Numerical simulations conducted ...

  4. The frequency of Tay-Sachs disease causing mutations in the Brazilian Jewish population justifies a carrier screening program

    Directory of Open Access Journals (Sweden)

    Roberto Rozenberg

    Full Text Available CONTEXT: Tay-Sachs disease is an autosomal recessive disease characterized by progressive neurologic degeneration, fatal in early childhood. In the Ashkenazi Jewish population the disease incidence is about 1 in every 3,500 newborns and the carrier frequency is 1 in every 29 individuals. Carrier screening programs for Tay-Sachs disease have reduced disease incidence by 90% in high-risk populations in several countries. The Brazilian Jewish population is estimated at 90,000 individuals. Currently, there is no screening program for Tay-Sachs disease in this population. OBJECTIVE: To evaluate the importance of a Tay-Sachs disease carrier screening program in the Brazilian Jewish population by determining the frequency of heterozygotes and the acceptance of the program by the community. SETTING: Laboratory of Molecular Genetics - Institute of Biosciences - Universidade de São Paulo. PARTICIPANTS: 581 senior students from selected Jewish high schools. PROCEDURE: Molecular analysis of Tay-Sachs disease causing mutations by PCR amplification of genomic DNA, followed by restriction enzyme digestion. RESULTS: Among 581 students that attended educational classes, 404 (70% elected to be tested for Tay-Sachs disease mutations. Of these, approximately 65% were of Ashkenazi Jewish origin. Eight carriers were detected corresponding to a carrier frequency of 1 in every 33 individuals in the Ashkenazi Jewish fraction of the sample. CONCLUSION: The frequency of Tay-Sachs disease carriers among the Ashkenazi Jewish population of Brazil is similar to that of other countries where carrier screening programs have led to a significant decrease in disease incidence. Therefore, it is justifiable to implement a Tay-Sachs disease carrier screening program for the Brazilian Jewish population.

  5. Combined IR-Raman vs vibrational sum-frequency heterospectral correlation spectroscopy

    Science.gov (United States)

    Roy, Sandra; Beutier, Clémentine; Hore, Dennis K.

    2018-06-01

    Vibrational sum-frequency generation spectroscopy is a valuable probe of surface structure, particularly when the same molecules are present in one of the adjacent bulk solid or solution phases. As a result of the non-centrosymmetric requirement of SFG, the signal generated is a marker of the extent to which the molecules are ordered in an arrangement that breaks the up-down symmetry at the surface. In cases where the accompanying changes in the bulk are of interest in understanding and interpreting the surface structure, simultaneous analysis of the bulk IR absorption or bulk Raman scattering is helpful, and may be used in heterospectral surface-bulk two-dimensional correlation. We demonstrate that, in such cases, generating a new type of bulk spectrum that combines the IR and Raman amplitudes is a better candidate than the individual IR and Raman spectra for the purpose of correlation with the SFG signal.

  6. Efficient concept for generation of diffraction-limited green light by sum-frequency generation of spectrally combined tapered diode lasers

    DEFF Research Database (Denmark)

    Müller, André; Jensen, Ole Bjarlin; Hasler, Karl-Heinz

    2012-01-01

    In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power signific......In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power...... significantly. By combining two distributed Bragg reflector tapered diode lasers we achieve a 2.5–3.2 fold increase in power and a maximum of 3.9 W of diffraction-limited green light. At this power level, green diode laser systems have a high application potential, e.g., within the biomedical field. Our concept...

  7. Direct Frequency Comb Spectroscopy of Alkali Atoms

    Science.gov (United States)

    Pradhananga, Trinity; Palm, Christopher; Nguyen, Khoa; Guttikonda, Srikanth; Kimball, Derek Jackson

    2011-11-01

    We are using direct frequency comb spectroscopy to study transition frequencies and excited state hyperfine structure in potassium and rubidium using 2-photon transitions excited directly with the frequency-doubled output of a erbium fiber optical frequency comb. The frequency comb output is directed in two counterpropagating directions through a vapor cell containing the atomic vapor of interest. A pair of optical filters is used to select teeth of the comb in order to identify the transition wavelengths. A photomultiplier tube (PMT) measures fluorescence from a decay channel wavelength selected with another optical filter. Using different combinations of filters enables a wide range of transitions to be investigated. By scanning the repetition rate, a Doppler-free spectrum can be obtained enabling kHz-resolution spectral measurements. The thermal motion of the atoms in the vapor cell actually eliminates the need to fine-tune the offset frequency and repetition rate, alleviating a somewhat challenging requirement for spectroscopy of cold atoms. Our investigations are laying the groundwork for a long-term research program to use direct frequency comb spectroscopy to understand the complex spectra of rare-earth atoms.

  8. Computer program for calculating the resonant frequency, shunt impedance and quality factor of a pill-box cavity in a storage ring

    International Nuclear Information System (INIS)

    Aguero, V.M.; Ng, K.Y.

    1983-10-01

    Keil and Zotter have analyzed the electromagnetic fields excited by the longitudinal density fluctuations of an unbunched relativistic particle beam drifting in a corrugated vacuum chamber of circular cross section. At higher frequencies, these corrugations become resonant cavities. Zotter has written a computer program known as KN7C to compute the resonant frequencies. However, in the actual use of KN7C, some difficulties are encountered. To surmount these difficulties, the program known as CAVITY was written to analyze this pill-box shaped resonant cavity. Although there are many input variables to this program, only two are essential and need to be specified. They are BD = b/d = the ratio of the circular beampipe radius to that of the pill-box cavity and GD = g/d where g is the length of the cavity. When they are specified, CAVITY will print out the dimensionless normalized fundamental resonant frequency FD, shunt impedance Z and figure of merit Q. From these, the actual resonant frequency, shunt impedance and figure of merit can be deduced. The program is described and a listing is provided

  9. Frequency of the severe combined immunodeficiency disease gene among horses in Morocco.

    Science.gov (United States)

    Piro, M; Benjouad, A; Tligui, N S; El Allali, K; El Kohen, M; Nabich, A; Ouragh, L

    2008-09-01

    Severe combined immunodeficiency disease (SCID) of horses is an autosomal, recessive hereditary disease occurring among Arabian or crossbred Arabian horses. The genetic defect responsible was previously identified as a 5-base pair deletion in the gene encoding the catalytic subunit of the DNA dependant protein kinase (DNA-PKcs). This study was carried out to determine the frequency of SCID and identify horses carrying the gene for SCID among Arabian and Arabian crossbred stallions and mares in Morocco using a DNA-based test. Twenty-one horses were SCID carriers: 14 (7%) Arabians, 6 (4%) Arab-Barbs and one (33%) Anglo-Arab. After analysing their genealogy, 3 imported stallions were identified that disseminated the mutant gene of DNA-PKcs in Morocco.

  10. Linear combination of forecasts with numerical adjustment via MINIMAX non-linear programming

    Directory of Open Access Journals (Sweden)

    Jairo Marlon Corrêa

    2016-03-01

    Full Text Available This paper proposes a linear combination of forecasts obtained from three forecasting methods (namely, ARIMA, Exponential Smoothing and Artificial Neural Networks whose adaptive weights are determined via a multi-objective non-linear programming problem, which seeks to minimize, simultaneously, the statistics: MAE, MAPE and MSE. The results achieved by the proposed combination are compared with the traditional approach of linear combinations of forecasts, where the optimum adaptive weights are determined only by minimizing the MSE; with the combination method by arithmetic mean; and with individual methods

  11. An Assessment of Demand for a Combined PharmD-MBA Program at the University of Saskatchewan.

    Science.gov (United States)

    Mansell, Kerry; Bruneau-Bouchard, Antoine; Bruni-Bossio, Vincent

    2016-05-13

    (1) Background: Combined MBA programs are becoming increasingly popular, and it is anticipated that there will be 60 combined pharmacy-MBA programs across North America in 2015. We aimed to see if there would be support for a combined PharmD-MBA program at the University of Saskatchewan. (2) Methods: A questionnaire was distributed to 1st, 2nd, and 3rd year pharmacy students at the University of Saskatchewan. A separate questionnaire was developed and all practicing pharmacists in Saskatchewan were emailed a link to SurveyMonkey ® (Palo Alto, CA, USA) to fill it out online. In-person and phone interviews were conducted with pharmacy stakeholders in Saskatchewan and across the country. (3) Results: Of the 265 students, 193 (72.8%) were present on the days the questionnaires were distributed, and they all completed the questionnaires. When asked if they would have pursued a combined degree if the U of S had offered it when they entered the pharmacy program, 16.6% (32/193) and 37.3% (72/193) either strongly agreed or agreed and 29.0% (56/193) were unsure. When pharmacists were asked if an MBA would be valuable or applicable in their current job, 42.2% (128/303) agreed and 13.9% (42/303) strongly agreed. When asked if they felt students graduating with a combined degree would be at an advantage for certain job opportunities upon graduation, 33.6% (100/298) strongly agreed and 55.4% (165/298) agreed. A total of 8 interviews were conducted with key stakeholders from across Canada. Of these 8 stakeholders, only 2 were aware that other combined programs were offered. All of the stakeholders were in favour of the idea of a combined degree. Some felt it was important for the program to have a clear value proposition and healthcare related content would be desirable. (4) Conclusions: Overall, pharmacist, pharmacy student, and stakeholder input indicate that a combined program could be supported at the University of Saskatchewan.

  12. An Assessment of Demand for a Combined PharmD–MBA Program at the University of Saskatchewan

    Science.gov (United States)

    Mansell, Kerry; Bruneau-Bouchard, Antoine; Bruni-Bossio, Vincent

    2016-01-01

    (1) Background: Combined MBA programs are becoming increasingly popular, and it is anticipated that there will be 60 combined pharmacy–MBA programs across North America in 2015. We aimed to see if there would be support for a combined PharmD–MBA program at the University of Saskatchewan. (2) Methods: A questionnaire was distributed to 1st, 2nd, and 3rd year pharmacy students at the University of Saskatchewan. A separate questionnaire was developed and all practicing pharmacists in Saskatchewan were emailed a link to SurveyMonkey® (Palo Alto, CA, USA) to fill it out online. In-person and phone interviews were conducted with pharmacy stakeholders in Saskatchewan and across the country. (3) Results: Of the 265 students, 193 (72.8%) were present on the days the questionnaires were distributed, and they all completed the questionnaires. When asked if they would have pursued a combined degree if the U of S had offered it when they entered the pharmacy program, 16.6% (32/193) and 37.3% (72/193) either strongly agreed or agreed and 29.0% (56/193) were unsure. When pharmacists were asked if an MBA would be valuable or applicable in their current job, 42.2% (128/303) agreed and 13.9% (42/303) strongly agreed. When asked if they felt students graduating with a combined degree would be at an advantage for certain job opportunities upon graduation, 33.6% (100/298) strongly agreed and 55.4% (165/298) agreed. A total of 8 interviews were conducted with key stakeholders from across Canada. Of these 8 stakeholders, only 2 were aware that other combined programs were offered. All of the stakeholders were in favour of the idea of a combined degree. Some felt it was important for the program to have a clear value proposition and healthcare related content would be desirable. (4) Conclusions: Overall, pharmacist, pharmacy student, and stakeholder input indicate that a combined program could be supported at the University of Saskatchewan. PMID:28970393

  13. General-purpose RFQ design program

    International Nuclear Information System (INIS)

    Wadlinger, E.A.

    1984-01-01

    We have written a general-purpose, radio-frequency quadrupole (RFQ) design program that allows maximum flexibility in picking design algorithms. This program optimizes the RFQ on any combination of design parameters while simultaneously satisfying mutually compatible, physically required constraint equations. It can be very useful for deriving various scaling laws for RFQs. This program has a friendly user interface in addition to checking the consistency of the user-defined requirements and is written to minimize the effort needed to incorporate additional constraint equations. We describe the program and present some examples

  14. A combined stochastic programming and optimal control approach to personal finance and pensions

    DEFF Research Database (Denmark)

    Konicz, Agnieszka Karolina; Pisinger, David; Rasmussen, Kourosh Marjani

    2015-01-01

    The paper presents a model that combines a dynamic programming (stochastic optimal control) approach and a multi-stage stochastic linear programming approach (SLP), integrated into one SLP formulation. Stochastic optimal control produces an optimal policy that is easy to understand and implement....

  15. EMGAN: A computer program for time and frequency domain reduction of electromyographic data

    Science.gov (United States)

    Hursta, W. N.

    1975-01-01

    An experiment in electromyography utilizing surface electrode techniques was developed for the Apollo-Soyuz test project. This report describes the computer program, EMGAN, which was written to provide first order data reduction for the experiment. EMG signals are produced by the membrane depolarization of muscle fibers during a muscle contraction. Surface electrodes detect a spatially summated signal from a large number of muscle fibers commonly called an interference pattern. An interference pattern is usually so complex that analysis through signal morphology is extremely difficult if not impossible. It has become common to process EMG interference patterns in the frequency domain. Muscle fatigue and certain myopathic conditions are recognized through changes in muscle frequency spectra.

  16. Main and combined effects of musculoskeletal pain frequency and avoidant coping on sickness absence

    DEFF Research Database (Denmark)

    Christensen, Ulla; Schmidt, Lone; Hougaard, Charlotte Orsted

    2013-01-01

    Objective: Musculoskeletal pain and avoidant coping predicts sickness absence, but how these 2 predictors relate to each other is unknown. We examined the main and combined effects of musculoskeletal pain and avoidant, behavioural coping on incidence of sickness absence. Design and subjects......: Prospective cohort study of a sample of middle-aged Danes, economically active in 2006, reporting functional limitations due to musculoskeletal pain, n = 3115. Methods: Data included surveys from 2000 and 2006 and register data from 2007. Outcome was sickness absence exceeding 2 consecutive weeks in 2007....... The main effect of self-reported pain frequency and avoidant coping on sickness absence was analysed by multivariate logistic regression. The combined effect was calculated as departure from multiplicativity and by the inclusion of a product term. Results: Daily pain and use of avoidant coping were both...

  17. L1 Frequency in Foreign Language Acquisition: Recurrent Word Combinations in French and Spanish EFL Learner Writing

    Science.gov (United States)

    Paquot, Magali

    2017-01-01

    This study investigated French and Spanish EFL (English as a foreign language) learners' preferred use of three-word lexical bundles with discourse or stance-oriented function with a view to exploring the role of first language (L1) frequency effects in foreign language acquisition. Word combinations were extracted from learner performance data…

  18. Frequency of syphilis among antenatal clinic attendee in combined military hospital abbottabad

    International Nuclear Information System (INIS)

    Qayum, M.; Shaheen, N.; Khan, M.Q.A.; Ali, W.

    2015-01-01

    Frequency of syphilis among pregnant women attending Combined Military Hospital Abbottabad Study Design: Descriptive study. Material and Methods: A screening for syphilis of 500 married pregnant women presenting to antenatal clinics was carried out using the qualitative Rapid Plasma Regent (RPR) test/ Venereal Disease Research Laboratory (VDRL) test. The Treponema Palladium Haem-Agglutination Assay (TPHA) test was used as confirmatory test for all Venereal Disease Research Laboratory (VDRL) test positive cases. Results: A total of 8 women (1.6%) were positive for Venereal Disease Research Laboratory (VDRL) test. Out of these 4 (0.8%) were positive for Treponema Palladium Haem-Agglutination Assay (TPHA) test. All of these cases have bad obstetrical history. Conclusion: The sero-positivity of Venereal Disease Research Laboratory (VDRL) test is (1.6%), considered high among pregnant women reporting in obstetrics clinics of Combined Military Hospital Abbottabad. Similarly sero-positivity of Treponema Palladium Haem-Agglutination Assay (TPHA) test is (0.8%) considered high among the Venereal Disease Research Laboratory (VDRL) test population. Therefore Screening of syphilis in pregnancy especially in patients having bad obstetrical history (BOH) should be incorporated into the study. (author)

  19. Two-photon direct frequency comb spectroscopy of alkali atoms

    Science.gov (United States)

    Palm, Christopher; Pradhananga, Trinity; Nguyen, Khoa; Montcrieffe, Caitlin; Kimball, Derek

    2012-11-01

    We have studied transition frequencies and excited state hyperfine structure in rubidium using 2-photon transitions excited directly with the frequency-doubled output of a erbium fiber optical frequency comb. The frequency comb output is directed in two counterpropagating directions through a vapor cell containing the rubidium vapor. A pair of optical filters is used to select teeth of the comb in order to identify the transition wavelengths. A photomultiplier tube (PMT) measures fluorescence from a decay channel wavelength selected with another optical filter. Using different combinations of filters enables a wide range of transitions to be investigated. By scanning the repetition rate, a Doppler-free spectrum can be obtained enabling kHz-resolution spectral measurements. An interesting dependence of the 2-photon spectrum on the energy of the intermediate state of the 2-photon transition is discussed. Our investigations are laying the groundwork for a long-term research program to use direct frequency comb spectroscopy to understand the complex spectra of rare-earth atoms.

  20. Nonlinear radiation of waves at combination frequencies due to radiation-surface wave interaction in plasmas

    International Nuclear Information System (INIS)

    El Naggar, I.A.; Hussein, A.M.; Khalil, Sh.M.

    1992-09-01

    Electromagnetic waves radiated with combination frequencies from a semi-bounded plasma due to nonlinear interaction of radiation with surface wave (both of P-polarization) has been investigated. Waves are radiated both into vacuum and plasma are found to be P-polarized. We take into consideration the continuity at the plasma boundary of the tangential components of the electric field of the waves. The case of normal incidence of radiation and rarefield plasma layer is also studied. (author). 7 refs

  1. The Relation of Source Credibility and Message Frequency to Program Evaluation and Self-Confidence of Students in a Job Shadowing Program

    Science.gov (United States)

    Linnehan, Frank

    2004-01-01

    Using a pre- and post-test design, this study examined the relation of an adult's credibility and message frequency to the beliefs of female high school students participating in a job-shadowing program. Hypotheses were based on the Elaboration Likelihood Model of attitude formation and change. Findings indicate that credibility of the adult…

  2. Feasibility of a combined aerobic and strength training program and its effects on cognitive and physical function in institutionalized dementia patients. A pilot study.

    Directory of Open Access Journals (Sweden)

    Willem J R Bossers

    Full Text Available OBJECTIVES: We examined the feasibility of a combined aerobic and strength training program in institutionalized dementia patients and studied the effects on cognitive and physical function. METHODS: Thirty-three patients with dementia, recruited from one nursing home, participated in this non-randomized pilot study (25 women; age = 85.2±4.9 years; Mini Mental State Examination = 16.8±4.0. In phase 1 of the study, seventeen patients in the Exercise group (EG received a combined aerobic and strength training program for six weeks, five times per week, 30 minutes per session, in an individually supervised format and successfully concluded the pre and posttests. In phase 2 of the study, sixteen patients in the Social group (SG received social visits at the same frequency, duration, and format and successfully concluded the pre and posttests. RESULTS: Indices of feasibility showed that the recruitment and adherence rate, respectively were 46.2% and 86.3%. All EG patients completed the exercise program according to protocol without adverse events. After the six-week program, no significant differences on cognitive function tests were found between the EG and SG. There was a moderate effect size in favor for the EG for the Visual Memory Span Forward; a visual attention test. There were significant differences between groups in favor for the EG with moderate to large effects for the physical tests Walking Speed (p = .003, Six-Minute Walk Test (p = .031, and isometric quadriceps strength (p = .012. CONCLUSIONS: The present pilot study showed that it is feasible to conduct a combined aerobic and strength training program in institutionalized patients with dementia. The selective cognitive visual attention improvements and more robust changes in motor function in favor of EG vs. SG could serve as a basis for large randomized clinical trials. TRIAL REGISTRATION: trialregister.nl 1230.

  3. Feasibility of a combined aerobic and strength training program and its effects on cognitive and physical function in institutionalized dementia patients. A pilot study.

    Science.gov (United States)

    Bossers, Willem J R; Scherder, Erik J A; Boersma, Froukje; Hortobágyi, Tibor; van der Woude, Lucas H V; van Heuvelen, Marieke J G

    2014-01-01

    We examined the feasibility of a combined aerobic and strength training program in institutionalized dementia patients and studied the effects on cognitive and physical function. Thirty-three patients with dementia, recruited from one nursing home, participated in this non-randomized pilot study (25 women; age = 85.2±4.9 years; Mini Mental State Examination = 16.8±4.0). In phase 1 of the study, seventeen patients in the Exercise group (EG) received a combined aerobic and strength training program for six weeks, five times per week, 30 minutes per session, in an individually supervised format and successfully concluded the pre and posttests. In phase 2 of the study, sixteen patients in the Social group (SG) received social visits at the same frequency, duration, and format and successfully concluded the pre and posttests. Indices of feasibility showed that the recruitment and adherence rate, respectively were 46.2% and 86.3%. All EG patients completed the exercise program according to protocol without adverse events. After the six-week program, no significant differences on cognitive function tests were found between the EG and SG. There was a moderate effect size in favor for the EG for the Visual Memory Span Forward; a visual attention test. There were significant differences between groups in favor for the EG with moderate to large effects for the physical tests Walking Speed (p = .003), Six-Minute Walk Test (p = .031), and isometric quadriceps strength (p = .012). The present pilot study showed that it is feasible to conduct a combined aerobic and strength training program in institutionalized patients with dementia. The selective cognitive visual attention improvements and more robust changes in motor function in favor of EG vs. SG could serve as a basis for large randomized clinical trials. trialregister.nl 1230.

  4. Transdermal delivery of fluorescein isothiocyanate-dextrans using the combination of microneedles and low-frequency sonophoresis

    Directory of Open Access Journals (Sweden)

    Boonnada Pamornpathomkul

    2015-10-01

    Full Text Available This study aimed to evaluate the patient-friendly methods that are used in the delivery of hydrophilic macromolecules into deep skin layers, in particular, the combination of microneedles patch (MNs patch and low-frequency sonophoresis (SN. The hydrophilic macromolecule drug fluorescein isothiocyanate (FITC-dextrans (FD-4: MW 4.4 kDa was used as the model drug in our experimental design. In this study, excised porcine skin was used to investigate and optimize the key parameters that determine effective MNs- and SN-facilitated FD-4 delivery. In vitro skin permeation experiments revealed that the combination of MNs patch with SN had a superior enhancing effect of skin permeation for FD-4 compared to MNs alone, SN alone or untreated skin, respectively. The optimal parameters for the combination of MNs and SN included the following: 10 N insertion force of MNs, 4 W/cm2 SN intensity, 6 mm radiation diameter of the SN probe, 2 min application time, and the continuous mode duty cycle of SN. In addition, vertical sections of skin, clearly observed under a confocal microscope, confirmed that the combination of MNs and SN enhanced permeation of FD-4 into the deep skin layers. These studies suggest that the combination of MNs and SN techniques could have great potential in the delivery of hydrophilic macromolecules into deep skin.

  5. Study of the B s0overlineBs0 oscillation frequency using D s- ℓ + combinations in Z decays

    Science.gov (United States)

    Buskulic, D.; de Bonis, I.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Odier, P.; Pietrzyk, B.; Casado, M. P.; Chmeissani, M.; Crespo, J. M.; Delfino, M.; Efthymiopoulos, I.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Juste, A.; Martinez, M.; Orteu, S.; Pacheco, A.; Padilla, C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Teubert, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Girone, M.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Alemany, R.; Bazarko, A. O.; Bonvicini, G.; Cattaneo, M.; Comas, P.; Coyle, P.; Drevermann, H.; Forty, R. W.; Frank, M.; Hagelberg, R.; Harvey, J.; Janot, P.; Jost, B.; Kneringer, E.; Knobloch, J.; Lehraus, I.; Lutters, G.; Martin, E. B.; Mato, P.; Minten, A.; Miquel, R.; Mir, Ll. M.; Moneta, L.; Oest, T.; Pater, J. R.; Pusztaszeri, J.-F.; Ranjard, F.; Rensing, P.; Rolandi, L.; Schlatter, D.; Schmelling, M.; Schneider, O.; Tejessy, W.; Tomalin, I. R.; Venturi, A.; Wachsmuth, H.; Wagner, A.; Wildish, T.; Ajaltouni, Z.; Barrès, A.; Boyer, C.; Falvard, A.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rossignol, J.-M.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Wäänänen, A.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Zachariadou, K.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Bourdon, P.; Rougé, A.; Rumpf, M.; Valassi, A.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Focardi, E.; Parrini, G.; Corden, M.; Georgiopoulos, C.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Knowles, I. G.; Lynch, J. G.; O'Shea, V.; Raine, C.; Reeves, P.; Scarr, J. M.; Smith, K.; Thompson, A. S.; Thomson, F.; Thorn, S.; Turnbull, R. M.; Becker, U.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Rensch, B.; Schmidt, M.; Sommer, J.; Stenzel, H.; Tittel, K.; Werner, S.; Wunsch, M.; Abbaneo, D.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Stacey, A. M.; Williams, M. D.; Dissertori, G.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Sloan, T.; Williams, M. I.; Galla, A.; Greene, A. M.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Bencheikh, A. M.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Calvet, D.; Carr, J.; Diaconu, C.; Etienne, F.; Konstantinidis, N.; Payre, P.; Rousseau, D.; Talby, M.; Sadouki, A.; Thulasidas, M.; Trabelsi, K.; Aleppo, M.; Ragusa, F.; Abt, I.; Assmann, R.; Bauer, C.; Blum, W.; Dietl, H.; Dydak, F.; Ganis, G.; Gotzhein, C.; Jakobs, K.; Kroha, H.; Lütjens, G.; Lutz, G.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; Denis, R. St.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Jacquet, M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Nikolic, I.; Park, H. J.; Park, I. C.; Schune, M.-H.; Simion, S.; Veillet, J.-J.; Videau, I.; Azzurri, P.; Bagliesi, G.; Batignani, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; Dell'Orso, R.; Fantechi, R.; Ferrante, I.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Sciabà, A.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Vannini, C.; Verdini, P. G.; Walsh, J.; Blair, G. A.; Bryant, L. M.; Cerutti, F.; Chambers, J. T.; Gao, Y.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Maley, P.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Marx, B.; Perez, P.; Rander, J.; Renardy, J.-F.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Johnson, R. P.; Kim, H. Y.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Boswell, R.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Koksal, A.; Letho, M.; Newton, W. M.; Reeve, J.; Thompson, L. F.; Böhrer, A.; Brandt, S.; Büscher, V.; Cowan, G.; Grupen, C.; Minguet-Rodriguez, J.; Rivera, F.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Rothberg, J.; Wasserbaech, S.; Armstrong, S. R.; Bellantoni, L.; Elmer, P.; Feng, Z.; Ferguson, D. P. S.; Gao, Y. S.; González, S.; Grahl, J.; Greening, T. C.; Harton, J. L.; Hayes, O. J.; Hu, H.; McNamara, P. A.; Nachtman, J. M.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Schmitt, M.; Scott, I. J.; Sharma, V.; Walsh, A. M.; Wu, Sau Lan; Wu, X.; Yamartino, J. M.; Zheng, M.; Zobernig, G.; Aleph Collaboration

    1996-02-01

    A lower limit on the oscillation frequency of the B s0overlineBs0 system is obtained from approximately four million hadronic Z decays accumulated using the ALEPH detector at LEP from 1991 to 1995. Leptons are combined with opposite sign D s- candidates reconstructed in seven different decay modes as evidence of semileptonic B s0 decays. Criteria designed to ensure precise proper time reconstruction select 277D s-ℓ + combinations. The initial state of these B s0 candidates is determined using an algorithm optimized to efficiently utilise the tagging information available for each event. The limit at 95% confidence level on the B s0overlineBs0 oscillation frequency is Δms > 6.6 ps -1. The same data is used to update the measurement of the B s0 lifetime, τs = 1.54 -0.13+0.14 (stat) ± 0.04 (syst) ps.

  6. Modeling the energy consumption of programs: thermal aspects and Energy/Frequency Convexity Rule

    OpenAIRE

    De Vogeleer , Karel; Rao Vaddina , Kameswar; Brandner , Florian; Jouvelot , Pierre ,; Memmi , Gérard

    2017-01-01

    International audience; This article summarizes our current studies aiming at a better understanding of the energy consumption of a microprocessor during the execution of an application through a combination of theoretical results and experimental validations, The analysis of the transient thermal behavior and energy gains (ranging from 20 to 40% in some cases) via the adaptation of the clock frequency are of obvious practical interest. A general Passive Cooling Rule (PCR) for an isothermal o...

  7. Effects of a Combined Exercise Program Using an iPad for Older Adults.

    Science.gov (United States)

    Lee, Juhee; Jung, Dukyoo; Byun, Jinyee; Lee, Minkyung

    2016-04-01

    The purpose of this study was to examine the function, health status, and efficacy effects of a combined exercise program using an iPad among older women in Korea, a tech-savvy country. The study employed a pretest and posttest experimental design with a control group. The experimental group of subjects comprised 16 female older adults and the control group comprised 10 who were aged 65 years or older. The experimental group participated in a supervised group-based exercise program and an individualized home-based exercise program that involved the use of an iPad. The combined group and home-based exercise program consisted of group exercise, which took place in a senior center for 30 minutes weekly, and a home-based iPad exercise program, which the subjects followed at least 3 times a week. The collected data were analyzed using the Statistical Analysis System (SAS ver. 9.3 TS Level 1M0) program, which utilized a chi-square test, a Fisher exact test, a t-test, and a repeated-measures ANOVA. The results showed that cognitive status changed significantly over time, and there was an interaction between group and time. Further, self-efficacy for exercise and outcome expectations for exercise changed significantly over time. Exercise programs using iPad interventions may be useful for the management of cognitive functioning and the integration of functional physical abilities in older adults.

  8. Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

    International Nuclear Information System (INIS)

    Morawski, Ireneusz; Spiegelberg, Richard; Korte, Stefan; Voigtländer, Bert

    2015-01-01

    A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations

  9. Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

    Energy Technology Data Exchange (ETDEWEB)

    Morawski, Ireneusz [Peter Grünberg Institut (PGI-3) and JARA-Fundamentals of Future Information Technology, Forschungszentrum Jülich, 52425 Jülich (Germany); Institute of Experimental Physics, University of Wrocław, pl. M. Borna 9, 50-204 Wrocław (Poland); Spiegelberg, Richard; Korte, Stefan; Voigtländer, Bert [Peter Grünberg Institut (PGI-3) and JARA-Fundamentals of Future Information Technology, Forschungszentrum Jülich, 52425 Jülich (Germany)

    2015-12-15

    A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations.

  10. Hybrid Broadband Ground-Motion Simulations: Combining Long-Period Deterministic Synthetics with High-Frequency Multiple S-to-S Backscattering

    KAUST Repository

    Mai, Paul Martin; Imperatori, W.; Olsen, K. B.

    2010-01-01

    We present a new approach for computing broadband (0-10 Hz) synthetic seismograms by combining high-frequency (HF) scattering with low-frequency (LF) deterministic seismograms, considering finite-fault earthquake rupture models embedded in 3D earth structure. Site-specific HF-scattering Green's functions for a heterogeneous medium with uniformly distributed random isotropic scatterers are convolved with a source-time function that characterizes the temporal evolution of the rupture process. These scatterograms are then reconciled with the LF-deterministic waveforms using a frequency-domain optimization to match both amplitude and phase spectra around the target intersection frequency. The scattering parameters of the medium, scattering attenuation ηs, intrinsic attenuation ηi, and site-kappa, as well as frequency-dependent attenuation, determine waveform and spectral character of the HF-synthetics and thus affect the hybrid broadband seismograms. Applying our methodology to the 1994 Northridge earthquake and validating against near-field recordings at 24 sites, we find that our technique provides realistic broadband waveforms and consistently reproduces LF ground-motion intensities for two independent source descriptions. The least biased results, compared to recorded strong-motion data, are obtained after applying a frequency-dependent site-amplification factor to the broadband simulations. This innovative hybrid ground-motion simulation approach, applicable to any arbitrarily complex earthquake source model, is well suited for seismic hazard analysis and ground-motion estimation.

  11. Hybrid Broadband Ground-Motion Simulations: Combining Long-Period Deterministic Synthetics with High-Frequency Multiple S-to-S Backscattering

    KAUST Repository

    Mai, Paul Martin

    2010-09-20

    We present a new approach for computing broadband (0-10 Hz) synthetic seismograms by combining high-frequency (HF) scattering with low-frequency (LF) deterministic seismograms, considering finite-fault earthquake rupture models embedded in 3D earth structure. Site-specific HF-scattering Green\\'s functions for a heterogeneous medium with uniformly distributed random isotropic scatterers are convolved with a source-time function that characterizes the temporal evolution of the rupture process. These scatterograms are then reconciled with the LF-deterministic waveforms using a frequency-domain optimization to match both amplitude and phase spectra around the target intersection frequency. The scattering parameters of the medium, scattering attenuation ηs, intrinsic attenuation ηi, and site-kappa, as well as frequency-dependent attenuation, determine waveform and spectral character of the HF-synthetics and thus affect the hybrid broadband seismograms. Applying our methodology to the 1994 Northridge earthquake and validating against near-field recordings at 24 sites, we find that our technique provides realistic broadband waveforms and consistently reproduces LF ground-motion intensities for two independent source descriptions. The least biased results, compared to recorded strong-motion data, are obtained after applying a frequency-dependent site-amplification factor to the broadband simulations. This innovative hybrid ground-motion simulation approach, applicable to any arbitrarily complex earthquake source model, is well suited for seismic hazard analysis and ground-motion estimation.

  12. Study of the B$_{s}^{0}\\overline{B}_{s}^{0}$ oscillation frequency using D$_{s}^{-}$l$^{+}$ combinations in Z decays

    CERN Document Server

    Buskulic, Damir; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Odier, P; Pietrzyk, B; Casado, M P; Chmeissani, M; Crespo, J M; Delfino, M C; Efthymiopoulos, I; Fernández, E; Fernández-Bosman, M; Garrido, L; Juste, A; Martínez, M; Orteu, S; Pacheco, A; Padilla, C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Girone, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Alemany, R; Bazarko, A O; Bonvicini, G; Cattaneo, M; Comas, P; Coyle, P; Drevermann, H; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Lutters, G; Martin, E B; Mato, P; Minten, Adolf G; Miquel, R; Moneta, L; Oest, T; Pater, J R; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rolandi, Luigi; Schlatter, W D; Schmelling, M; Schneider, O; Tejessy, W; Tomalin, I R; Venturi, A; Wachsmuth, H W; Wagner, A; Wildish, T; Ajaltouni, Ziad J; Barrès, A; Boyer, C; Falvard, A; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rossignol, J M; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Wäänänen, A; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Zachariadou, K; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Rougé, A; Rumpf, M; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Corden, M; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Casper, David William; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Knowles, I G; Lynch, J G; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Thompson, A S; Thomson, F; Thorn, S; Turnbull, R M; Becker, U; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Rensch, B; Schmidt, M; Sommer, J; Stenzel, H; Tittel, K; Werner, S; Wunsch, M; Abbaneo, D; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Moutoussi, A; Nash, J; Sedgbeer, J K; Stacey, A M; Williams, M D; Dissertori, G; Girtler, P; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Williams, M I; Galla, A; Greene, A M; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Bencheikh, A M; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Diaconu, C A; Etienne, F; Konstantinidis, N P; Payre, P; Rousseau, D; Talby, M; Sadouki, A; Thulasidas, M; Trabelsi, K; Aleppo, M; Ragusa, F; Abt, I; Assmann, R W; Bauer, C; Blum, Walter; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Jakobs, K; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Nikolic, I A; Park, H J; Park, I C; Schune, M H; Simion, S; Veillet, J J; Videau, I; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Vannini, C; Verdini, P G; Walsh, J; Blair, G A; Bryant, L M; Cerutti, F; Chambers, J T; Gao, Y; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Maley, P; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Marx, B; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Boswell, R; Brew, C A J; Cartwright, S L; Combley, F; Köksal, A; Lehto, M H; Newton, W M; Reeve, J; Thompson, L F; Böhrer, A; Brandt, S; Büscher, V; Cowan, G D; Grupen, Claus; Minguet-Rodríguez, J A; Rivera, F; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y S; González, S; Grahl, J; Greening, T C; Harton, J L; Hayes, O J; Hu, H; McNamara, P A; Nachtman, J M; Orejudos, W; Pan, Y B; Saadi, Y; Schmitt, M; Scott, I J; Sharma, V; Walsh, A M; Wu Sau Lan; Wu, X; Yamartino, J M; Zheng, M; Zobernig, G

    1996-01-01

    A lower limit on the oscillation frequency of the BsBsbar system is obtained from approximately four million hadronic Z decays accumulated using the ALEPH detector at LEP from 1991 to 1995. Leptons are combined with opposite sign Ds- candidates reconstructed in seven different decay modes as evidence of semileptonic Bs decays. Criteria designed to ensure precise proper time reconstruction select 277 Ds-,l+ combinations. The initial state of these Bs candidates is determined using an algorithm optimized to efficiently utilise the tagging information available for each event. The limit at 95\\% confidence level on the BsBsbar oscillation frequency is delta_m_s > 6.6 ps^-1. The same data is used to update the measurement of the Bs lifetime, tau_s = 1.54 +0.14 (stat) +0.04 (syst) ps. -0.13 -0.04

  13. E-Hitz: a word frequency list and a program for deriving psycholinguistic statistics in an agglutinative language (Basque).

    Science.gov (United States)

    Perea, Manuel; Urkia, Miriam; Davis, Colin J; Agirre, Ainhoa; Laseka, Edurne; Carreiras, Manuel

    2006-11-01

    We describe a Windows program that enables users to obtain a broad range of statistics concerning the properties of word and nonword stimuli in an agglutinative language (Basque), including measures of word frequency (at the whole-word and lemma levels), bigram and biphone frequency, orthographic similarity, orthographic and phonological structure, and syllable-based measures. It is designed for use by researchers in psycholinguistics, particularly those concerned with recognition of isolated words and morphology. In addition to providing standard orthographic and phonological neighborhood measures, the program can be used to obtain information about other forms of orthographic similarity, such as transposed-letter similarity and embedded-word similarity. It is available free of charge from www .uv.es/mperea/E-Hitz.zip.

  14. A finite element computer program for the calculation of the resonant frequencies of anisotropic materials

    International Nuclear Information System (INIS)

    Fleury, W.H.; Rosinger, H.E.; Ritchie, I.G.

    1975-09-01

    A set of computer programs for the calculation of the flexural and torsional resonant frequencies of rectangular section bars of materials of orthotropic or higher symmetry are described. The calculations are used in the experimental determination and verification of the elastic constants of anisotropic materials. The simple finite element technique employed separates the inertial and elastic properties of the beam element into station and field transfer matrices respectively. It includes the Timoshenko beam corrections for flexure and Lekhnitskii's theory for torsion-flexure coupling. The programs also calculate the vibration shapes and surface nodal contours or Chladni figures of the vibration modes. (author)

  15. Software for Displaying High-Frequency Test Data

    Science.gov (United States)

    Elmore, Jason L.

    2003-01-01

    An easy-to-use, intuitive computer program was written to satisfy a need of test operators and data requestors to quickly view and manipulate high-frequency test data recorded at the East and West Test Areas at Marshall Space Flight Center. By enabling rapid analysis, this program makes it possible to reduce times between test runs, thereby potentially reducing the overall cost of test operations. The program can be used to perform quick frequency analysis, using multiple fast- Fourier-transform windowing and amplitude options. The program can generate amplitude-versus-time plots with full zoom capabilities, frequency-component plots at specified time intervals, and waterfall plots (plots of spectral intensity versus frequency at successive small time intervals, showing the changing frequency components over time). There are options for printing of the plots and saving plot data as text files that can be imported into other application programs. The program can perform all of the aforementioned plotting and plot-data-handling functions on a relatively inexpensive computer; other software that performs the same functions requires computers with large amounts of power and memory.

  16. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Masayuki; Ohnishi, Naofumi

    2016-01-01

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  17. Plasma filamentation and shock wave enhancement in microwave rockets by combining low-frequency microwaves with external magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masayuki, E-mail: m.takahashi@al.t.u-tokyo.ac.jp [Department of Aeronautics and Astronautics, The University of Tokyo, Bunkyo-ku 113-8656 (Japan); Ohnishi, Naofumi [Department of Aerospace Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2016-08-14

    A filamentary plasma is reproduced based on a fully kinetic model of electron and ion transports coupled with electromagnetic wave propagation. The discharge plasma transits from discrete to diffusive patterns at a 110-GHz breakdown, with decrease in the ambient pressure, because of the rapid electron diffusion that occurs during an increase in the propagation speed of the ionization front. A discrete plasma is obtained at low pressures when a low-frequency microwave is irradiated because the ionization process becomes more dominant than the electron diffusion, when the electrons are effectively heated by the low-frequency microwave. The propagation speed of the plasma increases with decrease in the incident microwave frequency because of the higher ionization frequency and faster plasma diffusion resulting from the increase in the energy-absorption rate. An external magnetic field is applied to the breakdown volume, which induces plasma filamentation at lower pressures because the electron diffusion is suppressed by the magnetic field. The thrust performance of a microwave rocket is improved by the magnetic fields corresponding to the electron cyclotron resonance (ECR) and its higher-harmonic heating, because slower propagation of the ionization front and larger energy-absorption rates are obtained at lower pressures. It would be advantageous if the fundamental mode of ECR heating is coupled with a lower frequency microwave instead of combining the higher-harmonic ECR heating with the higher frequency microwave. This can improve the thrust performance with smaller magnetic fields even if the propagation speed increases because of the decrease in the incident microwave frequency.

  18. [Preference on screening frequency and willingness-to-pay for multiple-cancer packaging screening programs in urban populations in China].

    Science.gov (United States)

    Zhu, J; Huang, H Y; Mao, A Y; Sun, Z X; Qiu, W Q; Lei, H K; Dong, P; Huang, J W; Bai, Y N; Sun, X J; Liu, G X; Wang, D B; Liao, X Z; Ren, J S; Guo, L W; Lan, L; Zhou, Q; Song, B B; Liu, Y Q; Du, L B; Zhu, L; Cao, R; Wang, J L; Mai, L; Ren, Y; Zhou, J Y; Sun, X H; Wu, S L; Qi, X; Lou, P A; Cai, B; Li, N; Zhang, K; He, J; Dai, M; Shi, J F

    2018-02-10

    Objective: From an actual cancer screening service demanders' perspective, we tried to understand the preference on screening frequency and willingness-to-pay for the packaging screening program on common cancers and to evaluate its long-term sustainability in urban populations in China. Methods: From 2012 to 2014, a multi-center cross-sectional survey was conducted among the actual screening participants from 13 provinces covered by the Cancer Screening Program in Urban China (CanSPUC). By face-to-face interview, information regarding to preference to screening frequency, willingness-to-pay for packaging screening program, maximum amount on payment and related reasons for unwillingness were investigated. Results: A total of 31 029 participants were included in this survey, with an average age as (55.2±7.5) years and median annual income per family as 25 000 Chinese Yuan. People's preference to screening frequency varied under different assumptions ( " totally free" and "self-paid" ). When the packaging screening was assumed totally free, 93.9% of residents would prefer to take the screening program every 1 to 3 years. However, the corresponding proportion dropped to 67.3% when assuming a self-paid pattern. 76.7% of the participants had the willingness-to-pay for the packaging screening, but only 11.2% of them would like to pay more than 500 Chinese Yuan (the expenditure of the particular packaging screening were about 1 500 Chinese Yuan). The remaining 23.3% of residents showed no willingness-to-pay, and the main reasons were unaffordable expenditure (71.7%) and feeling'no need'(40.4%). Conclusions: People who participated in the CanSPUC program generally tended to choose high-frequency packaging screening program, indicating the high potential acceptance for scale-up packaging screening, while it needs cautious assessments and rational guidance to the public. Although about seven in ten of the residents were willing to pay, the payment amount was limited

  19. Stable radio frequency dissemination by simple hybrid frequency modulation scheme.

    Science.gov (United States)

    Yu, Longqiang; Wang, Rong; Lu, Lin; Zhu, Yong; Wu, Chuanxin; Zhang, Baofu; Wang, Peizhang

    2014-09-15

    In this Letter, we propose a fiber-based stable radio frequency transfer system by a hybrid frequency modulation scheme. Creatively, two radio frequency signals are combined and simultaneously transferred by only one laser diode. One frequency component is used to detect the phase fluctuation, and the other one is the derivative compensated signal providing a stable frequency for the remote end. A proper ratio of the frequencies of the components is well maintained by parameter m to avoid interference between them. Experimentally, a stable 200 MHz signal is transferred over 100 km optical fiber with the help of a 1 GHz detecting signal, and fractional instability of 2×10(-17) at 10(5) s is achieved.

  20. Combined effects of food deprivation and food frequency on the amount and temporal distribution of schedule-induced drinking.

    Science.gov (United States)

    Castilla, José Luis; Pellón, Ricardo

    2013-11-01

    Under intermittent food schedules animals develop temporally organized behaviors throughout interfood intervals, with behaviors early in the intervals (interim) normally occurring in excess. Schedule-induced drinking (a prototype of interim, adjunctive behavior) is related to food deprivation and food frequency. This study investigated the interactions that resulted from combining different food-deprivation levels (70%, 80% or 90% free-feeding weights) with different food-occurrence frequencies (15-, 30- or 60-s interfood intervals) in a within-subjects design. Increases in food deprivation and food frequency generally led to increased licking, with greater differences due to food deprivation as interfood intervals became shorter. Distributions of licking were modestly shifted to later in the interfood interval as interfood intervals lengthened, a result that was most marked under 90% food deprivation, which also resulted in flatter distributions. It would therefore appear that food deprivation modulates the licking rate and the distribution of licking in different ways. Effects of food deprivation and food frequency are adequately explained by a theory of adjunctive behavior based on delayed food reinforcement, in contrast to alternative hypotheses. © Society for the Experimental Analysis of Behavior.

  1. Program elaborated of combined regime for on-line and off-line problems

    International Nuclear Information System (INIS)

    Ivanova, A.B.; Ioramashvili, Eh.Sh.; Polyakov, B.F.; Razdol'skaya, L.A.

    1979-01-01

    A description of the part of operational system designed for organization of packet treatment of algol tasks combined with the on-line system is provided. A block-scheme of the operational system functioning in the packet regime is presented. The ''Director'' program is the main part of the operational system which is responsible for the functioning of the algol programs. Its starting for the first time is carried out by the operator. All the subsequent process of the operation is automized. Problems connected with the organization of interruptions appearing in the cases of failures and as a reaction for the end of operation of any algol program or some of its links are considered

  2. A Design of Mechanical Frequency Converter Linear and Non-linear Spring Combination for Energy Harvesting

    International Nuclear Information System (INIS)

    Yamamoto, K; Fujita, T; Kanda, K; Maenaka, K; Badel, A; Formosa, F

    2014-01-01

    In this study, the improvement of energy harvesting from wideband vibration with random change by using a combination of linear and nonlinear spring system is investigated. The system consists of curved beam spring for non-linear buckling, which supports the linear mass-spring resonator. Applying shock acceleration generates a snap through action to the buckling spring. From the FEM analysis, we showed that the snap through acceleration from the buckling action has no relationship with the applied shock amplitude and duration. We use this uniform acceleration as an impulse shock source for the linear resonator. It is easy to obtain the maximum shock response from the uniform snap through acceleration by using a shock response spectrum (SRS) analysis method. At first we investigated the relationship between the snap-through behaviour and an initial curved deflection. Then a time response result for non-linear springs with snap through and minimum force that makes a buckling behaviour were obtained by FEM analysis. By obtaining the optimum SRS frequency for linear resonator, we decided its resonant frequency with the MATLAB simulator

  3. Low Frequency Waves Detected in a Large Wave Flume under Irregular Waves with Different Grouping Factor and Combination of Regular Waves

    Directory of Open Access Journals (Sweden)

    Luigia Riefolo

    2018-02-01

    Full Text Available This paper describes a set of experiments undertaken at Universitat Politècnica de Catalunya in the large wave flume of the Maritime Engineering Laboratory. The purpose of this study is to highlight the effects of wave grouping and long-wave short-wave combinations regimes on low frequency generations. An eigen-value decomposition has been performed to discriminate low frequencies. In particular, measured eigen modes, determined through the spectral analysis, have been compared with calculated modes by means of eigen analysis. The low frequencies detection appears to confirm the dependence on groupiness of the modal amplitudes generated in the wave flume. Some evidence of the influence of low frequency waves on runup and transport patterns are shown. In particular, the generation and evolution of secondary bedforms are consistent with energy transferred between the standing wave modes.

  4. POD and PPP with multi-frequency processing

    Science.gov (United States)

    Roldán, Pedro; Navarro, Pedro; Rodríguez, Daniel; Rodríguez, Irma

    2017-04-01

    Precise Orbit Determination (POD) and Precise Point Positioning (PPP) are methods for estimating the orbits and clocks of GNSS satellites and the precise positions and clocks of user receivers. These methods are traditionally based on processing the ionosphere-free combination. With this combination, the delay introduced in the signal when passing through the ionosphere is removed, taking advantage of the dependency of this delay with the square of the frequency. It is also possible to process the individual frequencies, but in this case it is needed to properly model the ionospheric delay. This modelling is usually very challenging, as the electron content in the ionosphere experiences important temporal and spatial variations. These two options define the two main kinds of processing: the dual-frequency ionosphere-free processing, typically used in the POD and in certain applications of PPP, and the single-frequency processing with estimation or modelisation of the ionosphere, mostly used in the PPP processing. In magicGNSS, a software tool developed by GMV for POD and PPP, a hybrid approach has been implemented. This approach combines observations from any number of individual frequencies and any number of ionosphere-free combinations of these frequencies. In such a way, the observations of ionosphere-free combination allow a better estimation of positions and orbits, while the inclusion of observations from individual frequencies allows to estimate the ionospheric delay and to reduce the noise of the solution. It is also possible to include other kind of combinations, such as geometry-free combination, instead of processing individual frequencies. The joint processing of all the frequencies for all the constellations requires both the estimation or modelisation of ionospheric delay and the estimation of inter-frequency biases. The ionospheric delay can be estimated from the single-frequency or dual-frequency geometry-free observations, but it is also possible

  5. Large LOCA-earthquake combination probability assessment - Load combination program. Project 1 summary report

    Energy Technology Data Exchange (ETDEWEB)

    Lu, S; Streit, R D; Chou, C K

    1980-01-01

    This report summarizes work performed for the U.S. Nuclear Regulatory Commission (NRC) by the Load Combination Program at the Lawrence Livermore National Laboratory to establish a technical basis for the NRC to use in reassessing its requirement that earthquake and large loss-of-coolant accident (LOCA) loads be combined in the design of nuclear power plants. A systematic probabilistic approach is used to treat the random nature of earthquake and transient loading to estimate the probability of large LOCAs that are directly and indirectly induced by earthquakes. A large LOCA is defined in this report as a double-ended guillotine break of the primary reactor coolant loop piping (the hot leg, cold leg, and crossover) of a pressurized water reactor (PWR). Unit 1 of the Zion Nuclear Power Plant, a four-loop PWR-1, is used for this study. To estimate the probability of a large LOCA directly induced by earthquakes, only fatigue crack growth resulting from the combined effects of thermal, pressure, seismic, and other cyclic loads is considered. Fatigue crack growth is simulated with a deterministic fracture mechanics model that incorporates stochastic inputs of initial crack size distribution, material properties, stress histories, and leak detection probability. Results of the simulation indicate that the probability of a double-ended guillotine break, either with or without an earthquake, is very small (on the order of 10{sup -12}). The probability of a leak was found to be several orders of magnitude greater than that of a complete pipe rupture. A limited investigation involving engineering judgment of a double-ended guillotine break indirectly induced by an earthquake is also reported. (author)

  6. Large LOCA-earthquake combination probability assessment - Load combination program. Project 1 summary report

    International Nuclear Information System (INIS)

    Lu, S.; Streit, R.D.; Chou, C.K.

    1980-01-01

    This report summarizes work performed for the U.S. Nuclear Regulatory Commission (NRC) by the Load Combination Program at the Lawrence Livermore National Laboratory to establish a technical basis for the NRC to use in reassessing its requirement that earthquake and large loss-of-coolant accident (LOCA) loads be combined in the design of nuclear power plants. A systematic probabilistic approach is used to treat the random nature of earthquake and transient loading to estimate the probability of large LOCAs that are directly and indirectly induced by earthquakes. A large LOCA is defined in this report as a double-ended guillotine break of the primary reactor coolant loop piping (the hot leg, cold leg, and crossover) of a pressurized water reactor (PWR). Unit 1 of the Zion Nuclear Power Plant, a four-loop PWR-1, is used for this study. To estimate the probability of a large LOCA directly induced by earthquakes, only fatigue crack growth resulting from the combined effects of thermal, pressure, seismic, and other cyclic loads is considered. Fatigue crack growth is simulated with a deterministic fracture mechanics model that incorporates stochastic inputs of initial crack size distribution, material properties, stress histories, and leak detection probability. Results of the simulation indicate that the probability of a double-ended guillotine break, either with or without an earthquake, is very small (on the order of 10 -12 ). The probability of a leak was found to be several orders of magnitude greater than that of a complete pipe rupture. A limited investigation involving engineering judgment of a double-ended guillotine break indirectly induced by an earthquake is also reported. (author)

  7. Infrared, diode laser spectroscopy of the Ar--N2O complex: Observation of the intermolecular bending mode in combination with the highest frequency intramolecular stretching mode

    International Nuclear Information System (INIS)

    Hu, T.A.; Chappell, E.L.; Sharpe, S.W.

    1993-01-01

    Rotationally resolved vibrational spectra consisting of a-type transitions have been observed for the low-frequency, intermolecular bending mode in combination with the highest frequency, intramolecular stretching mode of Ar--N 2 O. Analysis of the spectral data places the origin of the combination band at 2256.1 cm -1 while the origin of the intramolecular stretching fundamental is at 2223.9 cm -1 . The difference between these two origins is approximately 32.2 cm -1 and agrees well with our calculated frequency of 31.5 cm -1 for the intermolecular bending mode, which was obtained by analysis of the centrifugal distortion constants. In addition, argon--nitrous oxide exhibits an anomalously large inertial defect of 10.96 amu A 2 in the combination state. This indicates a breakdown in the assumption of separation between vibration and rotation. While much of the inertial defect in the ground state can be accounted for by including Coriolis interactions, that occurring in the combination state is only partially accounted for by a similar analysis. Small, but significant changes, are observed in both the radial and angular parameters for Ar--N 2 O when going from the ground to the combination state, indicating large amplitude motion. The combination band is approximately 200 times less intense than the high-frequency, stretching fundamental of Ar--N 2 O. In addition, over 400 new rovibrational transitions are assigned to the previously observed 1 0 1 intramolecular stretching fundamental of the complex, and the subsequent rotational analysis is found to be in close agreement with earlier studies. Data were taken on a newly built, rapid-scan, diode laser spectrometer that incorporates a 12 cmx200 μm pulsed slit-expansion nozzle

  8. NET-2 Network Analysis Program

    International Nuclear Information System (INIS)

    Malmberg, A.F.

    1974-01-01

    The NET-2 Network Analysis Program is a general purpose digital computer program which solves the nonlinear time domain response and the linearized small signal frequency domain response of an arbitrary network of interconnected components. NET-2 is capable of handling a variety of components and has been applied to problems in several engineering fields, including electronic circuit design and analysis, missile flight simulation, control systems, heat flow, fluid flow, mechanical systems, structural dynamics, digital logic, communications network design, solid state device physics, fluidic systems, and nuclear vulnerability due to blast, thermal, gamma radiation, neutron damage, and EMP effects. Network components may be selected from a repertoire of built-in models or they may be constructed by the user through appropriate combinations of mathematical, empirical, and topological functions. Higher-level components may be defined by subnetworks composed of any combination of user-defined components and built-in models. The program provides a modeling capability to represent and intermix system components on many levels, e.g., from hole and electron spatial charge distributions in solid state devices through discrete and integrated electronic components to functional system blocks. NET-2 is capable of simultaneous computation in both the time and frequency domain, and has statistical and optimization capability. Network topology may be controlled as a function of the network solution. (U.S.)

  9. Combined resonant tank capacitance and pulse frequency modulation control for ZCS-SR inverter-fed high voltage DC power supply

    International Nuclear Information System (INIS)

    Lee, S S; Iqbal, S; Kamarol, M

    2011-01-01

    Conventional pulse frequency modulated (PFM) zero current switching (ZCS) series resonant (SR) inverter fed high voltage dc power supplies have nearly zero switching loss. However, they have limitations of poor controllability at light loads and large output voltage ripple at low switching frequencies. To address these problems, this paper proposes a combined resonant tank capacitance and pulse frequency modulation based control approach. For the realization of the proposed control approach, the tank circuit of the resonant inverter is made up of several resonant capacitors that are switched into or out of the tank circuit by electromechanical switches. The output voltage of the converter is regulated by digitally modulating the resonant tank capacitance and narrowly varying the switching frequency. The proposed control scheme has several features, namely a wide range of controllability even at light loads, less output voltage ripple, and less current stress on the inverter's power switches at light loads. Therefore, the proposed control approach alleviates most of the problems associated with conventional PFM. Experimental results obtained from a scaled down laboratory prototype are presented to verify the effectiveness of the proposed system.

  10. Combining total internal reflection sum frequency spectroscopy spectral imaging and confocal fluorescence microscopy.

    Science.gov (United States)

    Allgeyer, Edward S; Sterling, Sarah M; Gunewardene, Mudalige S; Hess, Samuel T; Neivandt, David J; Mason, Michael D

    2015-01-27

    Understanding surface and interfacial lateral organization in material and biological systems is critical in nearly every field of science. The continued development of tools and techniques viable for elucidation of interfacial and surface information is therefore necessary to address new questions and further current investigations. Sum frequency spectroscopy (SFS) is a label-free, nonlinear optical technique with inherent surface specificity that can yield critical organizational information on interfacial species. Unfortunately, SFS provides no spatial information on a surface; small scale heterogeneities that may exist are averaged over the large areas typically probed. Over the past decade, this has begun to be addressed with the advent of SFS microscopy. Here we detail the construction and function of a total internal reflection (TIR) SFS spectral and confocal fluorescence imaging microscope directly amenable to surface investigations. This instrument combines, for the first time, sample scanning TIR-SFS imaging with confocal fluorescence microscopy.

  11. An intensive combined training program modulates physical, physiological, biomotoric, and technical parameters in women basketball players.

    Science.gov (United States)

    Kilinç, Fatih

    2008-11-01

    The purpose of this study was the investigation of the effects of an intensive combined training program based on the pretest scores of a university women's basketball team on their physical, physiological, biomotoric, and technical features. Twenty-four university volunteers were equally divided into two groups: an experiment group (intensive combined training group) and a control (technical training) group. The 10-week intensive combined training program was performed on the experiment group according to their pretest outcomes. Before and at the end of each period of training, which was scheduled four times a week, the physical, physiological, biomotoric, and technical performance of each subject were determined. With respect to the pre- and posttest measurements, the basketball group showed significant differences (p training program performed on university women basketball players had a significant effect on improving their physical, physiological, biomotoric, and technical features. It proved to be highly recommendable for female basketball players who are preparing for short-term tournaments; the basketball group in this study won a championship.

  12. Synthesis of High-Frequency Ground Motion Using Information Extracted from Low-Frequency Ground Motion

    Science.gov (United States)

    Iwaki, A.; Fujiwara, H.

    2012-12-01

    Broadband ground motion computations of scenario earthquakes are often based on hybrid methods that are the combinations of deterministic approach in lower frequency band and stochastic approach in higher frequency band. Typical computation methods for low-frequency and high-frequency (LF and HF, respectively) ground motions are the numerical simulations, such as finite-difference and finite-element methods based on three-dimensional velocity structure model, and the stochastic Green's function method, respectively. In such hybrid methods, LF and HF wave fields are generated through two different methods that are completely independent of each other, and are combined at the matching frequency. However, LF and HF wave fields are essentially not independent as long as they are from the same event. In this study, we focus on the relation among acceleration envelopes at different frequency bands, and attempt to synthesize HF ground motion using the information extracted from LF ground motion, aiming to propose a new method for broad-band strong motion prediction. Our study area is Kanto area, Japan. We use the K-NET and KiK-net surface acceleration data and compute RMS envelope at four frequency bands: 0.5-1.0 Hz, 1.0-2.0 Hz, 2.0-4.0 Hz, .0-8.0 Hz, and 8.0-16.0 Hz. Taking the ratio of the envelopes of adjacent bands, we find that the envelope ratios have stable shapes at each site. The empirical envelope-ratio characteristics are combined with low-frequency envelope of the target earthquake to synthesize HF ground motion. We have applied the method to M5-class earthquakes and a M7 target earthquake that occurred in the vicinity of Kanto area, and successfully reproduced the observed HF ground motion of the target earthquake. The method can be applied to a broad band ground motion simulation for a scenario earthquake by combining numerically-computed low-frequency (~1 Hz) ground motion with the empirical envelope ratio characteristics to generate broadband ground motion

  13. Aerobic Exercise Combined with Techniques Programe Can Be Increased Groundstroke Skill of Tennis Athlet

    OpenAIRE

    Nasrulloh, Ahmad

    2012-01-01

    Professional tennis athletes should be able to master all the basic techniques of playing tennis and having physical fitness. Therefore, it is necessary to get an exercise that can give meaning to the skills and physical fitness. One of the proper exercises is with aerobic exercise combined with the technique.Aerobic exercise program combined with techniques is: (1) a number of players consisting of six to seven people with backward sequential formation techniques performing forehand and back...

  14. [HIV prevention program for young people--the WYSH Project as a model of "combination prevention"].

    Science.gov (United States)

    Ono-Kihara, Masako

    2010-03-01

    In face of the HIV pandemic that still grows, unsuccessful efforts of developing biomedical control measures or the failure of cognitive-behavioral approach to show sustained social level effectiveness, behavioral strategy is now expected to evolve into a structural prevention ("combination prevention") that involves multiple behavioral goals and multilevel approaches. WYSH Project is a combination prevention project for youth developed through socio-epidemiological approach that integrates epidemiology with social science such as social marketing and mixed method. WYSH Project includes mass education programs for youth in schools and programs for out-of-school youth through cyber network and peer communication. Started in 2002, it expanded nationwide with supports from related ministries and parent-teacher associations and has grown into a single largest youth prevention project in Japan.

  15. A Survey of Graduates of Combined Emergency Medicine-Pediatrics Residency Programs: An Update.

    Science.gov (United States)

    Strobel, Ashley M; Chasm, Rose M; Woolridge, Dale P

    2016-10-01

    In 1998, emergency medicine-pediatrics (EM-PEDS) graduates were no longer eligible for the pediatric emergency medicine (PEM) sub-board certification examination. There is a paucity of guidance regarding the various training options for medical students who are interested in PEM. We sought to to determine attitudes and personal satisfaction of graduates from EM-PEDS combined training programs. We surveyed 71 graduates from three EM-PEDS residences in the United States. All respondents consider their combined training to be an asset when seeking a job, 92% find it to be an asset to their career, and 88% think it provided added flexibility to job searches. The most commonly reported shortcoming was their ineligibility for the PEM sub-board certification. The lack of this designation was perceived to be a detriment to securing academic positions in dedicated children's hospitals. When surveyed regarding which training offers the better skill set for the practice of PEM, 90% (44/49) stated combined EM-PEDS training. When asked which training track gives them the better professional advancement in PEM, 52% (23/44) chose combined EM-PEDS residency, 27% (12/44) chose a pediatrics residency followed by a PEM fellowship, and 25% (11/44) chose an EM residency then a PEM fellowship. No EM-PEDS respondents considered PEM fellowship training after the completion of the dual training program. EM-PEDS graduates found combined training to be an asset in their career. They felt that it provided flexibility in job searches, and that it was ideal training for the skill set required for the practice of PEM. EM-PEDS graduates' practices varied, including mixed settings, free-standing children's hospitals, and community emergency departments. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Hail frequency estimation across Europe based on a combination of overshooting top detections and the ERA-INTERIM reanalysis

    Science.gov (United States)

    Punge, H. J.; Bedka, K. M.; Kunz, M.; Reinbold, A.

    2017-12-01

    This article presents a hail frequency estimation based on the detection of cold overshooting cloud tops (OTs) from the Meteosat Second Generation (MSG) operational weather satellites, in combination with a hail-specific filter derived from the ERA-INTERIM reanalysis. This filter has been designed based on the atmospheric properties in the vicinity of hail reports registered in the European Severe Weather Database (ESWD). These include Convective Available Potential Energy (CAPE), 0-6-km bulk wind shear and freezing level height, evaluated at the nearest time step and interpolated from the reanalysis grid to the location of the hail report. Regions highly exposed to hail events include Northern Italy, followed by South-Eastern Austria and Eastern Spain. Pronounced hail frequency is also found in large parts of Eastern Europe, around the Alps, the Czech Republic, Southern Germany, Southern and Eastern France, and in the Iberic and Apennine mountain ranges.

  17. Calculation of axial secular frequencies in a nonlinear ion trap with hexapole, octupole, decapole and dodecapole superpositions by the combined methods of multiple scales and Lindstedt-Poincare

    International Nuclear Information System (INIS)

    Doroudi, A.; Emampour, M.; Emampour, M.

    2012-01-01

    In this paper a combination of the method of multiple scales and the method of Lindstedt-Poincare which is a perturbative technique is used for calculation of axial secular frequencies of a nonlinear ion trap in the presence of second ,third, fourth and fifth order nonlinear terms of the potential distribution within the trap. The frequencies are calculated. The calculated frequencies are compared with the results of multiple scales method and the exact results.

  18. BEAMPATH: a program library for beam dynamics simulation in linear accelerators

    International Nuclear Information System (INIS)

    Batygin, Y.K.

    1992-01-01

    A structured programming technique was used to develop software for space charge dominated beams investigation in linear accelerators. The method includes hierarchical program design using program independent modules and a flexible combination of modules to provide a most effective version of structure for every specific case of simulation. A modular program BEAMPATH was developed for 2D and 3D particle-in-cell simulation of beam dynamics in a structure containing RF gaps, radio-frequency quadrupoles (RFQ), multipole lenses, waveguides, bending magnets and solenoids. (author) 5 refs.; 2 figs

  19. A Simplified Analytical Technique for High Frequency Characterization of Resonant Tunneling Diode

    Directory of Open Access Journals (Sweden)

    DESSOUKI, A. A. S.

    2014-11-01

    Full Text Available his paper proposes a simplified analytical technique for high frequency characterization of the resonant tunneling diode (RTD. An equivalent circuit of the RTD that consists of a parallel combination of conductance, G (V, f, and capacitance, C (V, f is formulated. The proposed approach uses the measured DC current versus voltage characteristic of the RTD to extract the equivalent circuit elements parameters in the entire bias range. Using the proposed analytical technique, the frequency response - including the high frequency range - of many characteristic aspects of the RTD is investigated. Also, the maximum oscillation frequency of the RTD is calculated. The results obtained have been compared with those concluded and reported in the literature. The reported results in literature were obtained through simulation of the RTD at high frequency using either a computationally complicated quantum simulator or through difficult RF measurements. A similar pattern of results and highly concordant conclusion are obtained. The proposed analytical technique is simple, correct, and appropriate to investigate the behavior of the RTD at high frequency. In addition, the proposed technique can be easily incorporated into SPICE program to simulate circuits containing RTD.

  20. Effect of magnet/slot combination on triple-frequency magnetic force and vibration of permanent magnet motors

    Science.gov (United States)

    Huo, Mina; Wang, Shiyu; Xiu, Jie; Cao, Shuqian

    2013-10-01

    The relationship between magnet/slot combination and magnetic forces including unbalanced magnetic force (UMF) and cogging torque (CT) of permanent magnet (PM) motors is investigated by using superposition principle and mechanical and magnetic symmetries. The results show that magnetic force can be produced by all magnets passing a single slot, by all slots passing a single magnet, or by eccentricity, which respectively correspond to three frequency components. The results further show that net force/torque can be classified into three typical cases: UMF is suppressed and CT is excited, UMF excited and CT suppressed, and UMF and CT both suppressed, and consequently possible vibrations include three unique groups: rotational modes, translational modes, and balanced modes. The conclusion that combinations with the greatest common divisor (GCD) greater than unity can avoid UMF is mathematically verified, and at the same time lower CT harmonics are preliminarily addressed by the typical excitations. The above findings can create simple guidelines for the suppression of certain UMF and/or CT by using suitable combinations, which in turn can present approach to yield a more desirable response in high performance applications. The superposition effect and predicted relationship are verified by the transient magnetic Finite Element method. Since this work is motivated by symmetries, comparisons are made in order to give further insight into the inner force and vibration behaviors of general rotary power-transmission systems.

  1. Numerical simulation of atmospheric-pressure helium discharge driven by combined radio frequency and trapezoidal pulse sources

    International Nuclear Information System (INIS)

    Wang Qi; Sun Jizhong; Zhang Jianhong; Ding Zhenfeng; Wang Dezhen

    2010-01-01

    Atmospheric-pressure capacitive discharges driven by combined radio frequency (rf) and trapezoidal pulse sources are investigated using a one-dimensional self-consistent fluid model. The results show that the plasma intensity in the rf discharge can be enhanced drastically when a low duty ratio short pulse source is additionally applied. The mechanism for the increase in the plasma density can be attributed to a strong localized electric field induced by the applied short pulse; the strong electric field generates a great number of high energy electrons and chemically active particles, which subsequently generate more electrons and ions. The rf capacitive discharges with the aid of externally applied short pulses can achieve a high plasma density with better power efficiency.

  2. Combined blockade of vascular endothelial growth factor and programmed death 1 pathways in advanced kidney cancer.

    Science.gov (United States)

    Einstein, David J; McDermott, David F

    2017-06-01

    Targeted and immune-based therapies have improved outcomes in advanced kidney cancer, yet novel strategies are needed to extend the duration of these benefits and expand them to more patients. Combined inhibition of vascular endothelial growth factor (VEGF) and the programmed death 1 (PD-1)/programmed death ligand 1 (PD-L1) pathways with therapeutic agents already in clinical use may offer such a strategy. Here, we describe the development and clinical evaluation of VEGF inhibitors and, separately, PD-1/PD-L1 inhibitors. We present preclinical evidence of interaction between these pathways and the rationale for combined blockade. Beyond well-known effects on pathologic angiogenesis, VEGF blockade also may decrease immune tolerance and enhance PD-1/PD-L1 blockade. We conclude with the results of several early trials of combined VEGF and PD-1/PD-L1 blockade, which demonstrate encouraging antitumor activity, and we pose questions for future study.

  3. 40 CFR 51.355 - Test frequency and convenience.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test frequency and convenience. 51.355 Section 51.355 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Requirements § 51.355 Test frequency and convenience. (a) The performance standards for I/M programs assume an...

  4. A national survey of residents in combined Internal Medicine and Dermatology residency programs: educational experience and future plans.

    Science.gov (United States)

    Mostaghimi, Arash; Wanat, Karolyn; Crotty, Bradley H; Rosenbach, Misha

    2015-10-16

    In response to a perceived erosion of medical dermatology, combined internal medicine and dermatology programs (med/derm) programs have been developed that aim to train dermatologists who take care of medically complex patients. Despite the investment in these programs, there is currently no data with regards to the potential impact of these trainees on the dermatology workforce. To determine the experiences, motivations, and future plans of residents in combined med/derm residency programs. We surveyed residents at all United States institutions with both categorical and combined training programs in spring of 2012. Respondents used visual analog scales to rate clinical interests, self-assessed competency, career plans, and challenges. The primary study outcomes were comfort in taking care of patients with complex disease, future practice plans, and experience during residency. Twenty-eight of 31 med/derm residents (87.5%) and 28 of 91 (31%) categorical residents responded (overall response rate 46%). No significant differences were seen in self-assessed dermatology competency, or comfort in performing inpatient consultations, cosmetic procedures, or prescribing systemic agents. A trend toward less comfort in general dermatology was seen among med/derm residents. Med/derm residents were more likely to indicate career preferences for performing inpatient consultation and taking care of medically complex patients. Categorical residents rated their programs and experiences more highly. Med/derm residents have stronger interests in serving medically complex patients. Categorical residents are more likely to have a positive experience during residency. Future work will be needed to ascertain career choices among graduates once data are available.

  5. On-body calibration and processing for a combination of two radio-frequency personal exposimeters

    International Nuclear Information System (INIS)

    Thielens, Arno; Verloock, Leen; Tanghe, Emmeric; Martens, Luc; Joseph, Wout; Agneessens, Sam; Rogier, Hendrik

    2015-01-01

    Two radio-frequency personal exposimeters (PEMs) worn on both hips are calibrated on a subject in an anechoic chamber. The PEMs' response and crosstalk are determined for realistically polarised incident electric fields using this calibration. The 50 % confidence interval of the PEMs' response is reduced (2.6 dB on average) when averaged over both PEMs. A significant crosstalk (up to a ratio of 1.2) is measured, indicating that PEM measurements can be obfuscated by crosstalk. Simultaneous measurements with two PEMs are carried out in Ghent, Belgium. The highest exposure is measured for Global System for Mobile Communication down-link (0.052 mW m -2 on average), while the lowest exposure is found for Universal Mobile Telecommunications System uplink (0.061 μW m -2 on average). The authors recommend the use of a combination of multiple PEMs and, considering the multivariate data, to provide the mean vector and the covariance matrix next to the commonly listed univariate summary statistics, in future PEM studies. (authors)

  6. Combined distributed Raman and Bragg fiber temperature sensing using incoherent optical frequency domain reflectometry

    Directory of Open Access Journals (Sweden)

    M. Koeppel

    2018-02-01

    Full Text Available Optical temperature sensors offer unique features which make them indispensable for key industries such as the energy sector. However, commercially available systems are usually designed to perform either distributed or distinct hot spot temperature measurements since they are restricted to one measurement principle. We have combined two concepts, fiber Bragg grating (FBG temperature sensors and Raman-based distributed temperature sensing (DTS, to overcome these limitations. Using a technique called incoherent optical frequency domain reflectometry (IOFDR, it is possible to cascade several FBGs with the same Bragg wavelength in one fiber and simultaneously perform truly distributed Raman temperature measurements. In our lab we have achieved a standard deviation of 2.5 K or better at a spatial resolution in the order of 1 m with the Raman DTS. We have also carried out a field test in a high-voltage environment with strong magnetic fields where we performed simultaneous Raman and FBG temperature measurements using a single sensor fiber only.

  7. A daily herd Markov-chain model to study the reproductive and economic impact of reproductive programs combining timed artificial insemination and estrus detection.

    Science.gov (United States)

    Giordano, J O; Kalantari, A S; Fricke, P M; Wiltbank, M C; Cabrera, V E

    2012-09-01

    Our objective was to compare the economic and reproductive performance of programs combining timed artificial insemination (TAI) and different levels of AI after estrus detection (ED) using a daily Markov-chain model. A dairy herd was modeled with every cow following daily probabilistic events of aging, replacement, mortality, pregnancy, pregnancy loss, and calving. The probability of pregnancy depended on the combination of probability of insemination and conception rate (CR). All nonpregnant cows had a probability of pregnancy between the end of the voluntary waiting period and days in milk cutoff for AI. After the cutoff, cows were labeled as do not breed and replaced when milk production was below a minimum milk threshold. A similar model was created to represent a replacement heifer herd to simulate and adjust the supply and demand of replacements. The net value (NV) of a program was the sum of milk income over feed cost, replacement and mortality cost, income from newborns, and reproductive costs. The model was used to compare the NV of 19 programs. One program used 100% TAI (42% CR for first TAI and 30% for second-and-later services), whereas the other programs combined TAI with ED. The proportion of cows receiving AI after ED for the combined programs ranged from 30 to 80%, with levels of CR of 25, 30, and 35%. As the proportion of cows receiving AI after ED increased, the CR of cows receiving TAI decreased. The combined programs with CR of 35% for cows receiving AI after ED had the greatest NV and reproductive performance at all levels of ED. The program using 100% TAI had greater NV and better reproductive performance than all programs with 25% CR after ED inseminations, whereas it had very similar performance to combined programs with up to 60% of cows receiving AI after ED and 30% CR. The factor with the greatest relative contribution to the differences among programs was income over feed cost, followed by replacement and reproductive costs. Adjusting

  8. Frequency band adjustment match filtering based on variable frequency GPR antennas pairing scheme for shallow subsurface investigations

    Science.gov (United States)

    Shaikh, Shahid Ali; Tian, Gang; Shi, Zhanjie; Zhao, Wenke; Junejo, S. A.

    2018-02-01

    Ground penetrating Radar (GPR) is an efficient tool for subsurface geophysical investigations, particularly at shallow depths. The non-destructiveness, cost efficiency, and data reliability are the important factors that make it an ideal tool for the shallow subsurface investigations. Present study encompasses; variations in central frequency of transmitting and receiving GPR antennas (Tx-Rx) have been analyzed and frequency band adjustment match filters are fabricated and tested accordingly. Normally, the frequency of both the antennas remains similar to each other whereas in this study we have experimentally changed the frequencies of Tx-Rx and deduce the response. Instead of normally adopted three pairs, a total of nine Tx-Rx pairs were made from 50 MHz, 100 MHz, and 200 MHz antennas. The experimental data was acquired at the designated near surface geophysics test site of the Zhejiang University, Hangzhou, China. After the impulse response analysis of acquired data through conventional as well as varied Tx-Rx pairs, different swap effects were observed. The frequency band and exploration depth are influenced by transmitting frequencies rather than the receiving frequencies. The impact of receiving frequencies was noticed on the resolution; the more noises were observed using the combination of high frequency transmitting with respect to low frequency receiving. On the basis of above said variable results we have fabricated two frequency band adjustment match filters, the constant frequency transmitting (CFT) and the variable frequency transmitting (VFT) frequency band adjustment match filters. By the principle, the lower and higher frequency components were matched and then incorporated with intermediate one. Therefore, this study reveals that a Tx-Rx combination of low frequency transmitting with high frequency receiving is a better choice. Moreover, both the filters provide better radargram than raw one, the result of VFT frequency band adjustment filter is

  9. Conditioning of high voltage radio frequency cavities by using fuzzy logic in connection with rule based programming

    CERN Document Server

    Perréard, S

    1993-01-01

    Many processes are controlled by experts using some kind of mental model to decide actions and make conclusions. This model, based on heuristic knowledge, can often be conveniently represented in rules and has not to be particularly accurate. This is the case for the problem of conditioning high voltage radio-frequency cavities: the expert has to decide, by observing some criteria, if he can increase or if he has to decrease the voltage and by how much. A program has been implemented which can be applied to a class of similar problems. The kernel of the program is a small rule base, which is independent of the kind of cavity. To model a specific cavity, we use fuzzy logic which is implemented as a separate routine called by the rule base. We use fuzzy logic to translate from numeric to symbolic information. The example we chose for applying this kind of technique can be implemented by sequential programming. The two versions exist for comparison. However, we believe that this kind of programming can be powerf...

  10. Excitation of low-frequency residual currents at combination frequencies of an ionising two-colour laser pulse

    Science.gov (United States)

    Vvedenskii, N. V.; Kostin, V. A.; Laryushin, I. D.; Silaev, A. A.

    2016-05-01

    We have studied the processes of excitation of low-frequency residual currents in a plasma produced through ionisation of gases by two-colour laser pulses in laser-plasma schemes for THz generation. We have developed an analytical approach that allows one to find residual currents in the case when one of the components of a two-colour pulse is weak enough. The derived analytical expressions show that the effective generation of the residual current (and hence the effective THz generation) is possible if the ratio of the frequencies in the two-colour laser pulse is close to a rational fraction with a not very big odd sum of the numerator and denominator. The results of numerical calculations (including those based on the solution of the three-dimensional time-dependent Schrödinger equation) agree well with the analytical results.

  11. Extremely low frequency electromagnetic field in combination with β ...

    African Journals Online (AJOL)

    Fatemeh Sanie-Jahromi

    Extremely low frequency (<300 Hz) electromagnetic field (EMF) is shown to decrease ... Production and hosting by Elsevier B.V. This is an open access article under ..... mouse liver induced by morphine and protected by antioxidants.

  12. Probability-based load combinations for design of category I structures - overview of research program and recent results

    International Nuclear Information System (INIS)

    Reich, M.; Hwang, H.

    1984-01-01

    This paper discusses the probability-based load combinations for the program dealing with the design of Category I structures, currently being worked on at Brookhaven National Laboratory (BNL) for the Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission (NRC). The objective of this program is to develop a probabilistic approach for the safety evaluations of reactor containments and other seismic Category I structures subjected to multiple static and dynamic loadings. Furthermore, on the basis of the developed probabilistic approach, a load combination methodology for the design of seismic Category I structures will also be established. The major tasks of this program are: (1) establish probabilistic representations for various loads and structural resistance, (2) select appropriate structural analysis methods and identify limit states of structures, (3) develop a reliability analysis method applicable to nuclear structures, (4) apply the developed methodology to existing Category I structures in order to evaluate the reliability levels implied in the current design criteria, and (5) recommend load combination design criteria for Category I structures. When the program is completed, it will be possible to (1) provide a method that can evaluate the safety margins of existing containment and other Category I structures and (2) recommended probability-based load combinations and load factors for the design of Category I structures. At the present time, a reliability analysis method for seismic Category I concrete structures has been completed. By utilizing this method, it is possible to evaluate the safety of structures under various static and dynamic loads. In this paper, results of a reliability analysis of a realistic reinforced concrete containment structure under dead load, accidental pressure, and earthquake ground acceleration are presented to demonstrate the feasibility of the methodology. (orig.)

  13. Combining child social skills training with a parent early intervention program for inhibited preschool children.

    Science.gov (United States)

    Lau, Elizabeth X; Rapee, Ronald M; Coplan, Robert J

    2017-10-01

    Previous studies have demonstrated the efficacy of early intervention for anxiety in preschoolers through parent-education. The current study evaluated a six-session early intervention program for preschoolers at high risk of anxiety disorders in which a standard educational program for parents was supplemented by direct training of social skills to the children. Seventy-two children aged 3-5 years were selected based on high behavioural inhibition levels and concurrently having a parent with high emotional distress. Families were randomly assigned to either the intervention group, which consisted of six parent-education group sessions and six child social skills training sessions, or waitlist. After six months, families on waitlist were offered treatment consisting of parent-education only. Relative to waitlist, children in the combined condition showed significantly fewer clinician-rated anxiety disorders and diagnostic severity and maternal (but not paternal) reported anxiety symptoms and life interference at six months. Mothers also reported less overprotection. These gains were maintained at 12-month follow-up. Parent only education following waitlist produced similar improvements among children. Quasi-experimental comparison between combined and parent-only interventions indicated greater reductions from combined intervention according to clinician reports, but no significant differences on maternal reports. Results suggest that this brief early intervention program for preschoolers with both parent and child components significantly reduces risk and disorder in vulnerable children. The inclusion of a child component might have the potential to increase effects over parent-only intervention. However, future support for this conclusion through long-term, randomised controlled trials is needed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Reactor Materials Program process water piping indirect failure frequency

    International Nuclear Information System (INIS)

    Daugherty, W.L.

    1989-01-01

    Following completion of the probabilistic analyses, the LOCA Definition Project has been subject to various external reviews, and as a result the need for several revisions has arisen. This report updates and summarizes the indirect failure frequency analysis for the process water piping. In this report, a conservatism of the earlier analysis is removed, supporting lower failure frequency estimates. The analysis results are also reinterpreted in light of subsequent review comments

  15. Mode shape and natural frequency identification for seismic analysis from background vibration

    International Nuclear Information System (INIS)

    Bhan, S.; Wozniak, Z.

    1986-02-01

    The feasibility of calculating natural frequencies and mode shapes of major equipment in a CANDU reactor from the measurements of their response to background excitation has been studied. A review of vibration data measured at various locations in CANDU plants shows that structures responded to a combination of random and harmonic background excitation. Amplitude of measured vibration is sufficient to allow meaningful data analysis. Frequency content in the 0 to 50-Hz range, which is of interest for earthquake response, is present in some of the vibration measurements studied. Spectral techniques have been developed for determining the response function of structures from measured vibration response to background excitation. The natural frequencies and mode shapes are then evaluated graphically from the frequency function plots. The methodology has been tested on a simple cantilever beam with known natural frequencies and mode shapes. The comparison between the theoretical and the computed natural frequencies and mode shapes is good for the lower modes. However, better curve-fitting techniques will be required in future, especially for higher modes. Readily available equipment necessary for the measurement of background vibration in a CANDU plant (which is commercially available) has been identified. An experimental program has been proposed to verify the methodology developed in this study. Recommendations are also made to study methods to improve the accuracy of the mode shape and natural frequency prediction

  16. Characteristics and possibilities of computer program for fast assessment of primary frequency control of electric power interconnections

    Directory of Open Access Journals (Sweden)

    Ivanović Milan

    2011-01-01

    Full Text Available This paper presents the possibilities and practical features of a computer program for fast assessment of the effects of primary frequency regulation of electric power interconnections. It is based on two methods. The first one is the analytical method, which applies analytical expressions for the non-zero initial conditions, with a range of benefits provided by the analytical form, allowing consideration of possible structural changes in the power system during the analysis process. The second is a simulation method, with recurrent application of suitable drafted, fully decoupled difference equations. Capabilities and features of this computer program have been identified in case of isolated power system of Serbia, and then for the case of a widespread appreciation of its surrounding.

  17. Spectral beam combining of diode lasers with high efficiency

    DEFF Research Database (Denmark)

    Müller, André; Vijayakumar, Deepak; Jensen, Ole Bjarlin

    2012-01-01

    Based on spectral beam combining we obtain 16 W of output power, combining two 1063 nm DBR-tapered diode lasers. The spectral separation within the combined beam can be used for subsequent sum-frequency generation.......Based on spectral beam combining we obtain 16 W of output power, combining two 1063 nm DBR-tapered diode lasers. The spectral separation within the combined beam can be used for subsequent sum-frequency generation....

  18. Climate schools plus: An online, combined student and parent, universal drug prevention program

    Directory of Open Access Journals (Sweden)

    Louise K. Thornton

    2018-06-01

    Full Text Available Early initiation of substance use significantly increases one's risk of developing substance use dependence and mental disorders later in life. To interrupt this trajectory, effective prevention during the adolescent period is critical. Parents play a key role in preventing substance use and related harms among adolescents and parenting interventions have been identified as critical components of effective prevention programs. Despite this, there is currently no substance use prevention program targeting both students and parents that adopts online delivery to overcome barriers to implementation and sustainability. The Climate Schools Plus (CSP program was developed to meet this need. CSP is an online substance use prevention program for students and parents, based on the effective Climate Schools prevention program for students. This paper describes the development of the parent component of CSP including a literature review and results of a large scoping survey of parents of Australian high school students (n = 242. This paper also includes results of beta-testing of the developed program with relevant experts (n = 10, and parents of Australian high school students (n = 15. The CSP parent component consists of 1 a webinar which introduces shared rule ranking, 2 online modules and 3 summaries of student lessons. The parent program targets evidence-based modifiable factors associated with a delay in the onset of adolescent substance use and/or lower levels of adolescent substance use in the future; namely, rule-setting, monitoring, and modelling. To date, this is the first combined parent-student substance use prevention program to adopt an online delivery method. Keywords: Development, Prevention, Adolescent, Alcohol, Parent

  19. Combination of low frequency electroacupuncture plus subdissociative doses of ketamine in post-herpetic neuralgia patients. A pilot study

    Directory of Open Access Journals (Sweden)

    Bárbara B. Garrido-Suárez

    2017-11-01

    Full Text Available Context: Pain processing implicates multiple concurrent mechanisms of nociceptive transmission and modulation. Electroacupuncture (EA analgesia involves mainly the activation of the endogenous anti-nociceptive systems that modulate pain transmission in addition to the regulation of glial activity and inhibition of pro-inflammatory cytokines in the spinal cord. Aims: To examine the potential anti-hyperalgesic effects the EA and the combination EA-ketamine in patients with post-herpetic neuralgia (PHN. Methods: Sixty-eight patients with PHN irritable nociceptor type were randomly allocated to 3 groups: group I (n=26, that received treatment with EA (10 Hz, 2-3 mA, 0.5 ms, 20 min/15 sessions alone, group II (n=21 with a combination EA-ketamine (0.25-0.5 mg/kg, i.m. or group III (n=21 with sham EA-ketamine for 15 days. The average daily pain score (ADPS using the Likert scale, area and rate of dynamic allodynia, the rate of thermal allodynia, and frequency of intermittent lancinating pain were evaluated during five visits – before treatment and at 15, 30, 60, 90 days. Results: ADPS and sensory abnormalities decreased significantly concerning baseline data at 90 days in the three groups, but patients treated with the combination EA-ketamine significantly improved compared with the other groups. Conclusions: These results suggest that the combination EA-ketamine shows an early and long-term anti-hyperalgesic effect in PHN patients. However, a controlled clinical trial is necessary to confirm this hypothesis.

  20. Combining Self-Explaining with Computer Architecture Diagrams to Enhance the Learning of Assembly Language Programming

    Science.gov (United States)

    Hung, Y.-C.

    2012-01-01

    This paper investigates the impact of combining self explaining (SE) with computer architecture diagrams to help novice students learn assembly language programming. Pre- and post-test scores for the experimental and control groups were compared and subjected to covariance (ANCOVA) statistical analysis. Results indicate that the SE-plus-diagram…

  1. [Individual parameters of general low-frequency magnetic therapy as a possibility for improving the clinical efficacy of the combined treatment of patients with essential arterial hypertension].

    Science.gov (United States)

    Fedotov, V D; Maslov, A G; Lobkaeva, E P; Krylov, V N; Obukhova, E O

    2012-01-01

    A new approach is proposed for the choice of low-frequency magnetic therapy on an individual basis using the results of analysis of heart rhythm variability. The clinical efficiency of low-frequency magnetic therapy incorporated in the combined treatment of 65 patients aged between 25 and 45 years with essential arterial hypertension was estimated. The statistically significant positive effects of the treatment included normalization of blood pressure and characteristics of heart rhythm variability as well as resolution of clinical symptoms of vegetative dysregulation.

  2. A Multiple-star Combined Solution Program - Application to the Population II Binary μ Cas

    Science.gov (United States)

    Gudehus, D. H.

    2001-05-01

    A multiple-star combined-solution computer program which can simultaneously fit astrometric, speckle, and spectroscopic data, and solve for the orbital parameters, parallax, proper motion, and masses has been written and is now publicly available. Some features of the program are the ability to scale the weights at run time, hold selected parameters constant, handle up to five spectroscopic subcomponents for the primary and the secondary each, account for the light travel time across the system, account for apsidal motion, plot the results, and write the residuals in position to a standard file for further analysis. The spectroscopic subcomponent data can be represented by reflex velocities and/or by independent measurements. A companion editing program which can manage the data files is included in the package. The program has been applied to the Population II binary μ Cas to derive improved masses and an estimate of the primordial helium abundance. The source code, executables, sample data files, and documentation for OpenVMS and Unix, including Linux, are available at http://www.chara.gsu.edu/\\rlap\\ \\ gudehus/binary.html.

  3. [The effect of ivermectin on geohelminth frequency (i.e. as used in the onchocerciasis control program in Colombia)].

    Science.gov (United States)

    Knudson, Angélica; Ariza, Yoseth; López, Myriam C; Fajardo, Oscar S; Reyes, Patricia; Moncada, Ligia I; Duque, Sofía; Álvarez, Carlos A; Nicholls, Rubén S

    2012-08-01

    Evaluating the effect of ivermectin on soil-transmitted helminthes (STH) infection frequency in a Colombian population included in the Onchocerciasis Elimination Program for the Americas (OEPA). This was an impact evaluation study which adopted a longitudinal approach using the population of Naicioná (1996) as baseline for comparison to people from the same population as controls (2008). The cross-sectional approach involved comparing the reference population of Naicioná (2008) to the population of Dos Quebradas (2008) used as controls. Fecal samples were processed by a modified Ritchie-Frick method. Ascaris lumbricoides was the most frequently found parasite in Naicioná (60/121; 49.6 %: 37.8-63.895%CI) and in Dos Quebradas (36/76; 47.4 %: 33.2-65.6 95 % CI). Ivermectin's main effect on the population aged over 5 years was a decreased risk of Trichiuris trichiura infection in both longitudinal assessment (86 % reduction: 74-93 95 % CI) and cross-sectional assessment (63 %:24-82 95 % CI). A 93 % reduction (45-99 95 % CI) in Strongyloides stercoralis frequency was found in longitudinal assessment, compared to 85 % in cross-sectional assessment (-031-99 95 % CI). Ivermectin use in the OEPA is not sufficient for STH morbidity control. Integrated programs including education and basic sanitation are required.

  4. Evaluation of cephalogram using multi-objective frequency processing

    Energy Technology Data Exchange (ETDEWEB)

    Hagiwara, Sakae; Takizawa, Tsutomu; Osako, Miho; Kaneda, Takashi; Kasai, Kazutaka [Nihon Univ., Chiba (Japan). School of Dentistry at Matsudo

    2002-12-01

    A diagnosis with cephalogram is important for orthodontic treatment. Recently, computed radiography (CR) has been performed to the cephalogram. However, evaluation of multi-objective frequency processing (MFP) for cephalograms has been received little attention. The purpose of this study was to evaluate the cephalogram using MFP CR. At first, 450 lateral cephalograms were made, from 50 orthodontic patients, with 9 possible spatial frequency parameter combinations and a contrast scale held fixed in images processing. For each film, the clarity of radiographic images were estimated and scored with respect to landmark identification (total 26 points, 20 points of hard tissue and 6 points of soft tissue). A specific combination of spatial frequency scales (multi-frequency balance types (MRB) F-type, multi-frequency enhancement (MRE) 8) was proved to be adequate to achieve the optimal image quality in the cephalogram. (author)

  5. Evaluation of cephalogram using multi-objective frequency processing

    International Nuclear Information System (INIS)

    Hagiwara, Sakae; Takizawa, Tsutomu; Osako, Miho; Kaneda, Takashi; Kasai, Kazutaka

    2002-01-01

    A diagnosis with cephalogram is important for orthodontic treatment. Recently, computed radiography (CR) has been performed to the cephalogram. However, evaluation of multi-objective frequency processing (MFP) for cephalograms has been received little attention. The purpose of this study was to evaluate the cephalogram using MFP CR. At first, 450 lateral cephalograms were made, from 50 orthodontic patients, with 9 possible spatial frequency parameter combinations and a contrast scale held fixed in images processing. For each film, the clarity of radiographic images were estimated and scored with respect to landmark identification (total 26 points, 20 points of hard tissue and 6 points of soft tissue). A specific combination of spatial frequency scales (multi-frequency balance types (MRB) F-type, multi-frequency enhancement (MRE) 8) was proved to be adequate to achieve the optimal image quality in the cephalogram. (author)

  6. Combination of Wearable Multi-Biosensor Platform and Resonance Frequency Training for Stress Management of the Unemployed Population

    Directory of Open Access Journals (Sweden)

    Wanqing Wu

    2012-09-01

    Full Text Available Currently considerable research is being directed toward developing methodologies for controlling emotion or releasing stress. An applied branch of the basic field of psychophysiology, known as biofeedback, has been developed to fulfill clinical and non-clinical needs related to such control. Wearable medical devices have permitted unobtrusive monitoring of vital signs and emerging biofeedback services in a pervasive manner. With the global recession, unemployment has become one of the most serious social problems; therefore, the combination of biofeedback techniques with wearable technology for stress management of unemployed population is undoubtedly meaningful. This article describes a wearable biofeedback system based on combining integrated multi-biosensor platform with resonance frequency training (RFT biofeedback strategy for stress management of unemployed population. Compared to commercial system, in situ experiments with multiple subjects indicated that our biofeedback system was discreet, easy to wear, and capable of offering ambulatory RFT biofeedback.Moreover, the comparative studies on the altered autonomic nervous system (ANS modulation before and after three week RFT biofeedback training was performed in unemployed population with the aid of our wearable biofeedback system. The achieved results suggested that RFT biofeedback in combination with wearable technology was capable of significantly increasingoverall HRV, which indicated by decreasing sympathetic activities, increasing parasympathetic activities, and increasing ANS synchronization. After 3-week RFT-based respiration training, the ANS’s regulating function and coping ability of unemployed population have doubled, and tended toward a dynamic balance.

  7. The Brazilian time and frequency atomic standards program

    Directory of Open Access Journals (Sweden)

    Mushtaq Ahmed

    2008-06-01

    Full Text Available Cesium atomic beam clocks have been the workhorse for many demanding applications in science and technology for the past four decades. Tests of the fundamental laws of physics and the search for minute changes in fundamental constants, the synchronization of telecommunication networks, and realization of the satellite-based global positioning system would not be possible without atomic clocks. The adoption of optical cooling and trapping techniques, has produced a major advance in atomic clock precision. Cold-atom fountain and compact cold-atom clocks have also been developed. Measurement precision of a few parts in 10(15 has been demonstrated for a cold-atom fountain clock. We present here an overview of the time and frequency metrology program based on cesium atoms under development at USP São Carlos. This activity consists of construction and characterization of atomic-beam, and several variations of cold-atom clocks. We discuss the basic working principles, construction, evaluation, and important applications of atomic clocks in the Brazilian program.Relógios atômicos de feixe de Césio têm sido a base para diversas aplicações em ciência e tecnologia nas últimas quatro décadas. Testes de leis fundamentais de física, buscas por mínimas variações em constantes fundamentais, sincronização de redes de telecomunicações e o funcionamento do sistema de posicionamento global, baseado em satélites de navegação, não seriam possíveis sem os relógios atômicos. A adoção de técnicas de aprisionamento e resfriamento ópticos tem permitido um grande avanço na precisão dos relógios atômicos. Chafarizes de átomos frios e relógios compactos de átomos frios também têm sido desenvolvidos. Precisões de medida de algumas partes em 1015 foram demonstradas para relógios do tipo chafariz de átomos frios. Apresentamos uma visão geral do programa de metrologia de tempo e freqüência baseado em átomos de césio, em

  8. Combination of the mutation process with the sensitization and repair processes leading to increased frequencies of mutations in algal populations

    International Nuclear Information System (INIS)

    Necas, J.

    1977-01-01

    The possibility of combining the mutation process with the induction of the repair processes was studied to increase the mutation frequencies in algal populations after UV treatment. The repair process induced by visible light was found to be much more effective than the dark repair processes in the chlorococcal algae used. In these algae, visible light possibly does not induce only those repair processes which affect their DNA, but probably also certain recovery processes which affect their damaged structures and physiological functions. A suitable combination of the sensitization of algae cells by a DNA-base analogue before UV treatment and the induction of the light repair and recovery processes resulted in a rather high increase of viable mutations in chlorococcal algae. These findings may be useful in breeding chlorococcal algae, which have no possibility of hybridization other than somatic. (author)

  9. Combining agreement and frequency rating scales to optimize psychometrics in measuring behavioral health functioning.

    Science.gov (United States)

    Marfeo, Elizabeth E; Ni, Pengsheng; Chan, Leighton; Rasch, Elizabeth K; Jette, Alan M

    2014-07-01

    The goal of this article was to investigate optimal functioning of using frequency vs. agreement rating scales in two subdomains of the newly developed Work Disability Functional Assessment Battery: the Mood & Emotions and Behavioral Control scales. A psychometric study comparing rating scale performance embedded in a cross-sectional survey used for developing a new instrument to measure behavioral health functioning among adults applying for disability benefits in the United States was performed. Within the sample of 1,017 respondents, the range of response category endorsement was similar for both frequency and agreement item types for both scales. There were fewer missing values in the frequency items than the agreement items. Both frequency and agreement items showed acceptable reliability. The frequency items demonstrated optimal effectiveness around the mean ± 1-2 standard deviation score range; the agreement items performed better at the extreme score ranges. Findings suggest an optimal response format requires a mix of both agreement-based and frequency-based items. Frequency items perform better in the normal range of responses, capturing specific behaviors, reactions, or situations that may elicit a specific response. Agreement items do better for those whose scores are more extreme and capture subjective content related to general attitudes, behaviors, or feelings of work-related behavioral health functioning. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Alcohol Use Problems Mediate the Relation between Cannabis Use Frequency and College Functioning among Students Mandated to an Alcohol Diversion Program

    Science.gov (United States)

    McChargue, Dennis E.; Klanecky, Alicia K.; Anderson, Jennifer

    2012-01-01

    The present study examined the degree to which alcohol use problems explained the relationship between cannabis use frequency and college functioning. Undergraduates (N = 546) mandated to an alcohol diversion program at a Midwestern United States university completed screening questionnaires between October 2003 and April 2006. Sobel's (1982) test…

  11. A computational methodology for a micro launcher engine test bench using a combined linear static and dynamic in frequency response analysis

    Directory of Open Access Journals (Sweden)

    Ion DIMA

    2017-03-01

    Full Text Available This article aims to provide a quick methodology to determine the critical values of the forces, displacements and stress function of frequency, under a combined linear static (101 Solution - Linear Static and dynamic load in frequency response (108 Solution - Frequency Response, Direct Method, applied to a micro launcher engine test bench, using NASTRAN 400 Solution - Implicit Nonlinear. NASTRAN/PATRAN software is used. Practically in PATRAN the preprocessor has to define a linear or nonlinear static load at step 1 and a dynamic in frequency response load (time dependent at step 2. In Analyze the following options are chosen: for Solution Type Implicit Nonlinear Solution (SOL 400 is selected, for Subcases Static Load and Transient Dynamic is chosen and for Subcase Select the two cases static and dynamic will be selected. NASTRAN solver will overlap results from static analysis with the dynamic analysis. The running time will be reduced three times if using Krylov solver. NASTRAN SYSTEM (387 = -1 instruction is used in order to activate Krylov option. Also, in Analysis the OP2 Output Format shall be selected, meaning that in bdf NASTRAN input file the PARAM POST 1 instruction shall be written. The structural damping can be defined in two different ways: either at the material card or using the PARAM, G, 0.05 instruction (in this example a damping coefficient by 5% was used. The SDAMPING instruction in pair with TABDMP1 work only for dynamic in frequency response, modal method, or in direct method with viscoelastic material, not for dynamic in frequency response, direct method (DFREQ, with linear elastic material. The Direct method – DFREQ used in this example is more accurate. A set in translation of boundary conditions was used and defined at the base of the test bench.

  12. Helper T lymphocyte precursor frequency analysis in alloreactivity detection

    International Nuclear Information System (INIS)

    Cukrova, V.; Dolezalova, L.; Loudova, M.; Vitek, A.

    1998-01-01

    The utility of IL-2 secreting helper T lymphocyte precursors (HTLp) frequency testing has been evaluated for detecting alloreactivity. The frequency of HTLp was approached by limiting dilution assay. High HTLp frequency was detected in 20 out of 30 HLA matched unrelated pairs (67%). The comparison of HTLp and CTLp (cytotoxic T lymphocyte precursors) frequencies in HLA matched unrelated pairs showed that the two examinations are not fully alternative in detecting alloreactivity. This could suggest the utility of combined testing of both HTLp and CTLp frequencies for alloreactivity assessment. In contrast, five positive HTLp values were only found among 28 HLA genotypic identical siblings (18%). Previous CTLp limiting dilution studies showed very low or undetectable CTLp frequency results in that group. For that, HTLp assay remains to be the only cellular in vitro technique detecting alloreactivity in these combinations. (authors)

  13. The Effects of rTMS Combined with Motor Training on Functional Connectivity in Alpha Frequency Band.

    Science.gov (United States)

    Jin, Jing-Na; Wang, Xin; Li, Ying; Jin, Fang; Liu, Zhi-Peng; Yin, Tao

    2017-01-01

    It has recently been reported that repetitive transcranial magnetic stimulation combined with motor training (rTMS-MT) could improve motor function in post-stroke patients. However, the effects of rTMS-MT on cortical function using functional connectivity and graph theoretical analysis remain unclear. Ten healthy subjects were recruited to receive rTMS immediately before application of MT. Low frequency rTMS was delivered to the dominant hemisphere and non-dominant hand performed MT over 14 days. The reaction time of Nine-Hole Peg Test and electroencephalography (EEG) in resting condition with eyes closed were recorded before and after rTMS-MT. Functional connectivity was assessed by phase synchronization index (PSI), and subsequently thresholded to construct undirected graphs in alpha frequency band (8-13 Hz). We found a significant decrease in reaction time after rTMS-MT. The functional connectivity between the parietal and frontal cortex, and the graph theory statistics of node degree and efficiency in the parietal cortex increased. Besides the functional connectivity between premotor and frontal cortex, the degree and efficiency of premotor cortex showed opposite results. In addition, the number of connections significantly increased within inter-hemispheres and inter-regions. In conclusion, this study could be helpful in our understanding of how rTMS-MT modulates brain activity. The methods and results in this study could be taken as reference in future studies of the effects of rTMS-MT in stroke patients.

  14. Orthogonal Multi-Carrier DS-CDMA with Frequency-Domain Equalization

    Science.gov (United States)

    Tanaka, Ken; Tomeba, Hiromichi; Adachi, Fumiyuki

    Orthogonal multi-carrier direct sequence code division multiple access (orthogonal MC DS-CDMA) is a combination of orthogonal frequency division multiplexing (OFDM) and time-domain spreading, while multi-carrier code division multiple access (MC-CDMA) is a combination of OFDM and frequency-domain spreading. In MC-CDMA, a good bit error rate (BER) performance can be achieved by using frequency-domain equalization (FDE), since the frequency diversity gain is obtained. On the other hand, the conventional orthogonal MC DS-CDMA fails to achieve any frequency diversity gain. In this paper, we propose a new orthogonal MC DS-CDMA that can obtain the frequency diversity gain by applying FDE. The conditional BER analysis is presented. The theoretical average BER performance in a frequency-selective Rayleigh fading channel is evaluated by the Monte-Carlo numerical computation method using the derived conditional BER and is confirmed by computer simulation of the orthogonal MC DS-CDMA signal transmission.

  15. Time-Frequency Data Reduction for Event Related Potentials: Combining Principal Component Analysis and Matching Pursuit

    Directory of Open Access Journals (Sweden)

    Selin Aviyente

    2010-01-01

    Full Text Available Joint time-frequency representations offer a rich representation of event related potentials (ERPs that cannot be obtained through individual time or frequency domain analysis. This representation, however, comes at the expense of increased data volume and the difficulty of interpreting the resulting representations. Therefore, methods that can reduce the large amount of time-frequency data to experimentally relevant components are essential. In this paper, we present a method that reduces the large volume of ERP time-frequency data into a few significant time-frequency parameters. The proposed method is based on applying the widely used matching pursuit (MP approach, with a Gabor dictionary, to principal components extracted from the time-frequency domain. The proposed PCA-Gabor decomposition is compared with other time-frequency data reduction methods such as the time-frequency PCA approach alone and standard matching pursuit methods using a Gabor dictionary for both simulated and biological data. The results show that the proposed PCA-Gabor approach performs better than either the PCA alone or the standard MP data reduction methods, by using the smallest amount of ERP data variance to produce the strongest statistical separation between experimental conditions.

  16. Drag reduction of a car model by linear genetic programming control

    Science.gov (United States)

    Li, Ruiying; Noack, Bernd R.; Cordier, Laurent; Borée, Jacques; Harambat, Fabien

    2017-08-01

    We investigate open- and closed-loop active control for aerodynamic drag reduction of a car model. Turbulent flow around a blunt-edged Ahmed body is examined at ReH≈ 3× 105 based on body height. The actuation is performed with pulsed jets at all trailing edges (multiple inputs) combined with a Coanda deflection surface. The flow is monitored with 16 pressure sensors distributed at the rear side (multiple outputs). We apply a recently developed model-free control strategy building on genetic programming in Dracopoulos and Kent (Neural Comput Appl 6:214-228, 1997) and Gautier et al. (J Fluid Mech 770:424-441, 2015). The optimized control laws comprise periodic forcing, multi-frequency forcing and sensor-based feedback including also time-history information feedback and combinations thereof. Key enabler is linear genetic programming (LGP) as powerful regression technique for optimizing the multiple-input multiple-output control laws. The proposed LGP control can select the best open- or closed-loop control in an unsupervised manner. Approximately 33% base pressure recovery associated with 22% drag reduction is achieved in all considered classes of control laws. Intriguingly, the feedback actuation emulates periodic high-frequency forcing. In addition, the control identified automatically the only sensor which listens to high-frequency flow components with good signal to noise ratio. Our control strategy is, in principle, applicable to all multiple actuators and sensors experiments.

  17. Barkley's Parent Training Program, Working Memory Training and their Combination for Children with ADHD: Attention Deficit Hyperactivity Disorder.

    Directory of Open Access Journals (Sweden)

    Zahra Hosainzadeh Maleki

    2014-06-01

    Full Text Available The aim of the current study was to examine the effectiveness of Barkley's parent training program, working memory training and the combination of these two interventions for children with Attention deficit hyperactivity disorder (ADHD.In this study, 36 participants with ADHD (aged 6 to 12 years were selected by convenience sampling. Revision of the Swanson, Nolan and Pelham (SNAP questionnaire (SNAP-IV, Child Behavior Checklist (CBCL and clinical interviews were employed to diagnose ADHD. Wechsler Intelligence Scale for Children-Fourth Edition was also implemented. The participants were randomly assigned to the three intervention groups of Barkley's parent training program, working memory training and the combined group. SNAP-IV and CBCL were used as pre-tests and post-tests across all three groups. Data were analyzed using MANCOVA (SPSS version18.There was a significant difference (p< 0.05 in the decline of attention deficit and hyperactivity /impulsivity symptoms between the combined treatment group and working memory training group and also between the combined treatment group and the parent training group in SNAP. In terms of attention problems (experience-based subscales of CBCL, there was a significant difference (p< 0.001 between the combined treatment group and working memory training group. Furthermore, compared to the working memory training and parent training groups, the combined group demonstrated a significant decline (p< 0.01 in clinical symptoms of ADHD (based on DSM.It was revealed that combined treatment in comparison with the other two methods suppressed the clinical symptoms of ADHD more significantly.

  18. Real-time and high accuracy frequency measurements for intermediate frequency narrowband signals

    Science.gov (United States)

    Tian, Jing; Meng, Xiaofeng; Nie, Jing; Lin, Liwei

    2018-01-01

    Real-time and accurate measurements of intermediate frequency signals based on microprocessors are difficult due to the computational complexity and limited time constraints. In this paper, a fast and precise methodology based on the sigma-delta modulator is designed and implemented by first generating the twiddle factors using the designed recursive scheme. This scheme requires zero times of multiplications and only half amounts of addition operations by using the discrete Fourier transform (DFT) and the combination of the Rife algorithm and Fourier coefficient interpolation as compared with conventional methods such as DFT and Fast Fourier Transform. Experimentally, when the sampling frequency is 10 MHz, the real-time frequency measurements with intermediate frequency and narrowband signals have a measurement mean squared error of ±2.4 Hz. Furthermore, a single measurement of the whole system only requires approximately 0.3 s to achieve fast iteration, high precision, and less calculation time.

  19. Mixed frequency excitation of an electrostatically actuated resonator

    KAUST Repository

    Ramini, Abdallah

    2015-04-24

    We investigate experimentally and theoretically the dynamics of a capacitive resonator under mixed frequency excitation of two AC harmonic signals. The resonator is composed of a proof mass suspended by two cantilever beams. Experimental measurements are conducted using a laser Doppler vibrometer to reveal the interesting dynamics of the system when subjected to two-source excitation. A nonlinear single-degree-of-freedom model is used for the theoretical investigation. The results reveal combination resonances of additive and subtractive type, which are shown to be promising to increase the bandwidth of the resonator near primary resonance frequency. Our results also demonstrate the ability to shift the combination resonances to much lower or much higher frequency ranges. We also demonstrate the dynamic pull-in instability under mixed frequency excitation. © 2015 Springer-Verlag Berlin Heidelberg

  20. Monthly streamflow forecasting using continuous wavelet and multi-gene genetic programming combination

    Science.gov (United States)

    Hadi, Sinan Jasim; Tombul, Mustafa

    2018-06-01

    Streamflow is an essential component of the hydrologic cycle in the regional and global scale and the main source of fresh water supply. It is highly associated with natural disasters, such as droughts and floods. Therefore, accurate streamflow forecasting is essential. Forecasting streamflow in general and monthly streamflow in particular is a complex process that cannot be handled by data-driven models (DDMs) only and requires pre-processing. Wavelet transformation is a pre-processing technique; however, application of continuous wavelet transformation (CWT) produces many scales that cause deterioration in the performance of any DDM because of the high number of redundant variables. This study proposes multigene genetic programming (MGGP) as a selection tool. After the CWT analysis, it selects important scales to be imposed into the artificial neural network (ANN). A basin located in the southeast of Turkey is selected as case study to prove the forecasting ability of the proposed model. One month ahead downstream flow is used as output, and downstream flow, upstream, rainfall, temperature, and potential evapotranspiration with associated lags are used as inputs. Before modeling, wavelet coherence transformation (WCT) analysis was conducted to analyze the relationship between variables in the time-frequency domain. Several combinations were developed to investigate the effect of the variables on streamflow forecasting. The results indicated a high localized correlation between the streamflow and other variables, especially the upstream. In the models of the standalone layout where the data were entered to ANN and MGGP without CWT, the performance is found poor. In the best-scale layout, where the best scale of the CWT identified as the highest correlated scale is chosen and enters to ANN and MGGP, the performance increased slightly. Using the proposed model, the performance improved dramatically particularly in forecasting the peak values because of the inclusion

  1. Combined Two-Stage Stochastic Programming and Receding Horizon Control Strategy for Microgrid Energy Management Considering Uncertainty

    Directory of Open Access Journals (Sweden)

    Zhongwen Li

    2016-06-01

    Full Text Available Microgrids (MGs are presented as a cornerstone of smart grids. With the potential to integrate intermittent renewable energy sources (RES in a flexible and environmental way, the MG concept has gained even more attention. Due to the randomness of RES, load, and electricity price in MG, the forecast errors of MGs will affect the performance of the power scheduling and the operating cost of an MG. In this paper, a combined stochastic programming and receding horizon control (SPRHC strategy is proposed for microgrid energy management under uncertainty, which combines the advantages of two-stage stochastic programming (SP and receding horizon control (RHC strategy. With an SP strategy, a scheduling plan can be derived that minimizes the risk of uncertainty by involving the uncertainty of MG in the optimization model. With an RHC strategy, the uncertainty within the MG can be further compensated through a feedback mechanism with the lately updated forecast information. In our approach, a proper strategy is also proposed to maintain the SP model as a mixed integer linear constrained quadratic programming (MILCQP problem, which is solvable without resorting to any heuristics algorithms. The results of numerical experiments explicitly demonstrate the superiority of the proposed strategy for both island and grid-connected operating modes of an MG.

  2. An Extended System Frequency Response Model Considering Wind Power Participation in Frequency Regulation

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-11-01

    Full Text Available With increasing penetration of wind power into the power system, wind power participation in frequency regulation is regarded as a beneficial strategy to improve the dynamic frequency response characteristics of power systems. The traditional power system frequency response (SFR model, which only includes synchronous generators, is no longer suitable for power systems with high penetrated wind power. An extended SFR model, based on the reduced-order model of wind turbine generator (WTG and the traditional SFR model, is presented in this paper. In the extended SFR model, the reduced-order model of WTG with combined frequency control is deduced by employing small signal analysis theory. Afterwards, the stability analysis of a closed-loop control system for the extended SFR model is carried out. Time-domain simulations using a test system are performed to validate the effectiveness of the extended SFR model; this model can provide a simpler, clearer and faster way to analyze the dynamic frequency response characteristic for a high-wind integrated power systems. The impact of additional frequency control parameters and wind speed disturbances on the system dynamic frequency response characteristics are investigated.

  3. Forecasting Value-at-Risk Using High-Frequency Information

    Directory of Open Access Journals (Sweden)

    Huiyu Huang

    2013-06-01

    Full Text Available in the prediction of quantiles of daily Standard&Poor’s 500 (S&P 500 returns we consider how to use high-frequency 5-minute data. We examine methods that incorporate the high frequency information either indirectly, through combining forecasts (using forecasts generated from returns sampled at different intraday interval, or directly, through combining high frequency information into one model. We consider subsample averaging, bootstrap averaging, forecast averaging methods for the indirect case, and factor models with principal component approach, for both direct and indirect cases. We show that in forecasting the daily S&P 500 index return quantile (Value-at-Risk or VaR is simply the negative of it, using high-frequency information is beneficial, often substantially and particularly so, in forecasting downside risk. Our empirical results show that the averaging methods (subsample averaging, bootstrap averaging, forecast averaging, which serve as different ways of forming the ensemble average from using high-frequency intraday information, provide an excellent forecasting performance compared to using just low-frequency daily information.

  4. Dynamics of cardiovascular parameters in combined aortic malformations under the influence of a physical therapy program during the rehabilitation process

    Directory of Open Access Journals (Sweden)

    Serhii Kalmykov

    2017-12-01

    Full Text Available Purpose: to study hemodynamic parameters and the reaction of the cardiovascular system to the dosed physical load of patients combined aortic defect with heart failure of the I degree under the influence of the complex physical therapy program developed by us during the rehabilitation process. Material & Methods: the study involved 26 middle-aged men with a diagnosis: combined aortic valve disease, HF I st. Result: dynamics of functional parameters of the cardiovascular system of patients under the influence of the physical therapy program is analyzed. Conclusion: the combination of morning hygienic gymnastics, therapeutic gymnastics, independent activities and dosed walking with a therapeutic massage contributes to the normalization of vascular tone, motor-vascular reflexes and blood pressure, increasing the tolerance of the cardiovascular system to physical activity.

  5. Influence of the Bolsa Família program on nutritional status and food frequency of schoolchildren.

    Science.gov (United States)

    do Carmo, Ariene Silva; de Almeida, Lorena Magalhães; de Oliveira, Daniela Rodrigues; Dos Santos, Luana Caroline

    2016-01-01

    To evaluate the food frequency and nutritional status among students according to participation in the Bolsa Família program funded by the government. Cross-sectional study carried out with students from the fourth grade of elementary school in the municipal capital of the southeastern region of Brazil. Food consumption and anthropometry were investigated by a questionnaire administered in school, while participation in the Bolsa Família program and other socio-economic information was obtained through a protocol applied to mothers/guardians. Statistical analysis included the Mann-Whitney test, the chi-squared test, and Poisson regression with robust variance, and the 5% significance level was adopted. There were 319 children evaluated; 56.4% were male, with a median of 9.4 (8.6-11.9) years, and 37.0% were beneficiaries of Bolsa Família program. Between the two groups, there was high prevalence of regular soda consumption (34.3%), artificial juice (49.5%), and sweets (40.3%), while only 54.3% and 51.7% consumed fruits and vegetables regularly, respectively. Among participants of Bolsa Família program, a prevalence 1.24 times higher in the regular consumption of soft drinks (95% CI: 1.10-1.39) was identified compared to non-beneficiaries. The prevalence of overweight was higher in the sample (32.9%), with no difference according to participation in the program. The study found increased consumption of soft drinks among BFP participants. The high rate of overweight and poor eating habits denote the need to develop actions to promote healthy eating, especially for the beneficiaries of the Bolsa Família program, to promote improvements in nutritional status and prevent chronic diseases throughout life. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  6. Multiobjective Optimization for Electronic Circuit Design in Time and Frequency Domains

    Directory of Open Access Journals (Sweden)

    J. Dobes

    2013-04-01

    Full Text Available The multiobjective optimization provides an extraordinary opportunity for the finest design of electronic circuits because it allows to mathematically balance contradictory requirements together with possible constraints. In this paper, an original and substantial improvement of an existing method for the multiobjective optimization known as GAM (Goal Attainment Method is suggested. In our proposal, the GAM algorithm itself is combined with a procedure that automatically provides a set of parameters -- weights, coordinates of the reference point -- for which the method generates noninferior solutions uniformly spread over an appropriately selected part of the Pareto front. Moreover, the resulting set of obtained solutions is then presented in a suitable graphic form so that the solution representing the most satisfactory tradeoff can be easily chosen by the designer. Our system generates various types of plots that conveniently characterize results of up to four-dimensional problems. Technically, the procedures of the multiobjective optimization were created as a software add-on to the CIA (Circuit Interactive Analyzer program. This way enabled us to utilize many powerful features of this program, including the sensitivity analyses in time and frequency domains. As a result, the system is also able to perform the multiobjective optimization in the time domain and even highly nonlinear circuits can be significantly improved by our program. As a demonstration of this feature, a multiobjective optimization of a C-class power amplifier in the time domain is thoroughly described in the paper. Further, a four-dimensional optimization of a video amplifier is demonstrated with an original graphic representation of the Pareto front, and also some comparison with the weighting method is done. As an example of improving noise properties, a multiobjective optimization of a low-noise amplifier is performed, and the results in the frequency domain are shown

  7. Allele frequency changes due to hitch-hiking in genomic selection programs

    DEFF Research Database (Denmark)

    Liu, Huiming; Sørensen, Anders Christian; Meuwissen, Theo H E

    2014-01-01

    of inbreeding due to changes in allele frequencies and hitch-hiking. This study aimed at understanding the impact of using long-term genomic selection on changes in allele frequencies, genetic variation and the level of inbreeding. Methods Selection was performed in simulated scenarios with a population of 400......-BLUP, Genomic BLUP and Bayesian Lasso. Changes in allele frequencies at QTL, markers and linked neutral loci were investigated for the different selection criteria and different scenarios, along with the loss of favourable alleles and the rate of inbreeding measured by pedigree and runs of homozygosity. Results...

  8. Low-frequency wideband vibration energy harvesting by using frequency up-conversion and quin-stable nonlinearity

    Science.gov (United States)

    Wang, Chen; Zhang, Qichang; Wang, Wei

    2017-07-01

    This work presents models and experiments of an impact-driven and frequency up-converted wideband piezoelectric-based vibration energy harvester with a quintuple-well potential induced by the combination effect of magnetic nonlinearity and mechanical piecewise-linearity. Analysis shows that the interwell motions during coupled vibration period enable to increase electrical power output in comparison to conventional frequency up-conversion technology. Besides, the quintuple-well potential with shallower potential wells could extend the harvester's operating bandwidth to lower frequencies. Experiments demonstrate our proposed approach can dramatically boost the measured power of the energy harvester as much as 35 times while its lower cut-off frequency is two times lower than that of a conventional counterpart. These results reveal our proposed approach shows promise for powering portable wireless smart devices from low-intensity, low-frequency vibration sources.

  9. Frequency of primary uterine malignancy in hystrectomy specimens of postmenopausal women - a study of 255 cases at combined military hospital peshawar

    International Nuclear Information System (INIS)

    Bashir, S.; Bashir, J.

    2014-01-01

    Objective: To determine the frequency of primary uterine malignancy in hysterectomy specimens in women with postmenopausal bleeding. Study Design: A descriptive cross-sectional study. Place and Duration of study: It was conducted in the department of histopathology at Combined Military Hospital, Peshawar from 1st September 2010 to 31st May 2011. Material and Methods: A total of 255 hysterectomy specimens of postmenopausal women were examined grossly and microscopically to analyse the underlying pathology. Results: The mean age of patients with malignant diseases was 56.4 years and with benign diseases 49.3 years. Out of 255 patients 215 (95.6%) were found to have benign pathologies and 10 (4.4%) had malignant lesions. The frequency and histological pattern of primary uterine malignancy was; endometrial carcinoma 3.1%, cervical carcinoma 0.9% and leiomyosarcoma 0.4%. The benign pathologies included leiomyoma 35.6%, atrophic endometritis 16.4%, endometrial hyperplasia 15.1%, adenomysis 11.1%, endometrial polyp 10.2%, adenomyoma 6.7% and endometrial stromal nodule 0.4%. Conclusion: This study shows that frequency of malignancy in postmenopausal women is low in our set up and most of the underlying pathologies are benign. The most frequent malignancy found in postmenopausal women is endometrial carcinoma followed by cervical carcinoma. (author)

  10. Combined effect of electrode gap and radio frequency on power deposition and film growth kinetics in SiH4/H2 discharges

    International Nuclear Information System (INIS)

    Amanatides, E.; Mataras, D.; Rapakoulias, D.E.

    2002-01-01

    The combined effect of the variation of the interelectrode gap (1.3-2.5 cm) and radio frequency (13.56-50 MHz) on the properties of highly diluted silane in hydrogen discharges used for the deposition of microcrystalline silicon thin films is presented. The investigation included electrical and optical discharge measurements as well as the in situ determination of the film growth rate. In the lower frequencies regime, the increase of the interelectrode gap for the same applied voltage results in higher current flows and higher total power dissipation. On the other hand, at 50 MHz the variation of the interelectrode space has only a slight effect on the total power dissipation, due to the low excitation voltage. However, at all frequencies, the increase of the interelectrode space results in a drop of the power dissipation per discharge volume. This is related to the less effective energy transfer to the electrons that is due to the enhancement of the bulk relative to the sheath ohmic heating. The variation of the relative importance of the electron heating modes is reflected in the discharge radical production efficiency and the film growth rate

  11. Spectro-temporal modulation masking patterns reveal frequency selectivity.

    Science.gov (United States)

    Oetjen, Arne; Verhey, Jesko L

    2015-02-01

    The present study investigated the possibility that the human auditory system demonstrates frequency selectivity to spectro-temporal amplitude modulations. Threshold modulation depth for detecting sinusoidal spectro-temporal modulations was measured using a generalized masked threshold pattern paradigm with narrowband masker modulations. Four target spectro-temporal modulations were examined, differing in their temporal and spectral modulation frequencies: a temporal modulation of -8, 8, or 16 Hz combined with a spectral modulation of 1 cycle/octave and a temporal modulation of 4 Hz combined with a spectral modulation of 0.5 cycles/octave. The temporal center frequencies of the masker modulation ranged from 0.25 to 4 times the target temporal modulation. The spectral masker-modulation center-frequencies were 0, 0.5, 1, 1.5, and 2 times the target spectral modulation. For all target modulations, the pattern of average thresholds for the eight normal-hearing listeners was consistent with the hypothesis of a spectro-temporal modulation filter. Such a pattern of modulation-frequency sensitivity was predicted on the basis of psychoacoustical data for purely temporal amplitude modulations and purely spectral amplitude modulations. An analysis of separability indicates that, for the present data set, selectivity in the spectro-temporal modulation domain can be described by a combination of a purely spectral and a purely temporal modulation filter function.

  12. Determinant Factors of Technical-Tactical Combinations Frequency in standing position during Womens World Senior Championships 2009

    Directory of Open Access Journals (Sweden)

    David Eduardo López González

    2011-03-01

    Full Text Available Abstract Objective. To classify the perfomance  of world class women wrestlers as the frequency and characteristics of their Technical-Tactical Combinations (TTC with effectiveness in the standing position during the most important competition on the international calendar 2009.Methods.  In the TTC were characterized all standing position effectives by a sample of 70 wrestlers, occupants of the top 10 in each of the 7 weight categories convened. Descriptive variables were used 5 of effectiveness, technical group, and characteristics of its phases. Variables were obtained determining the effectiveness, measured the "success rate" achieved by each fighter, all through factor analysis. Later wrestlers were classified by cluster analysis by Ward's method.Results. The most important factor related to get a medal  was the execution of legs attacks of with several possible endings started with almost no contact with the opponent, followed by the use of low-risk attacks launched from a firm grip. The wrestlers opted mostly for defense and counter low risk. Most of the competitors who had good results using several and alternative projections also managed to end their attacks.Conclusions. Characterization Model used and the factors of effectiveness in the fight standing obtained provided detailed explanations of the performance characteristics of the best wrestlers in the Senior World Championships 2009. The design of this research can be applied year after year in both freestyle and women's.Key words: Technical - Tactical Combinations, Rules, Fighting Women, Factor Analysis and Effectiveness

  13. Determinant Factors of Technical-Tactical Combinations Frequency in standing position during Womens World Senior Championships 2009

    Directory of Open Access Journals (Sweden)

    David Eduardo López González

    2011-03-01

    Full Text Available Abstract  Objective. To classify the perfomance  of world class women wrestlers as the frequency and characteristics of their Technical-Tactical Combinations (TTC with effectiveness in the standing position during the most important competition on the international calendar 2009. Methods.  In the TTC were characterized all standing position effectives by a sample of 70 wrestlers, occupants of the top 10 in each of the 7 weight categories convened. Descriptive variables were used 5 of effectiveness, technical group, and characteristics of its phases. Variables were obtained determining the effectiveness, measured the "success rate" achieved by each fighter, all through factor analysis. Later wrestlers were classified by cluster analysis by Ward's method. Results. The most important factor related to get a medal  was the execution of legs attacks of with several possible endings started with almost no contact with the opponent, followed by the use of low-risk attacks launched from a firm grip. The wrestlers opted mostly for defense and counter low risk. Most of the competitors who had good results using several and alternative projections also managed to end their attacks. Conclusions. Characterization Model used and the factors of effectiveness in the fight standing obtained provided detailed explanations of the performance characteristics of the best wrestlers in the Senior World Championships 2009. The design of this research can be applied year after year in both freestyle and women's. Key words: Technical - Tactical Combinations, Rules, Fighting Women, Factor Analysis and Effectiveness

  14. Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Mahboobeh Alamolhoda

    2010-12-01

    Full Text Available Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiation of ultrasound (1 MHz and 150 kHz and single frequency irradiation in in-vivo experiments on breast adenocarcinoma tumors. Material and Method: In this study, the tumor-bearing mice were divided into 5 groups: control, sham, treated group for 30 min with 150 kHz frequency in continuous mode, another group with 1 MHz frequency in pulse mode, and treated group with combined dual frequency ultrasound (150 kHz in continuous mode and 1 MHz in 80% pulse mode. To evaluate the effects of ultrasound irradiation on tumor growth delay, the volumes of the tumors were investigated for 30 days. Tumor growth delay parameters including relative volume, inhibition ratio percentage and the required times for the tumor volume to reach to two (T2 and five (T5 times its initial volume were calculated. Results: The results showed that the treated groups with single frequency irradiation of 150 kHz continuous mode and 1 MHz pulse mode and combined dual frequency had statistically significant differences in tumor relative volume percentage during the period of 3 to 24 days after treatment (p

  15. Landslide susceptibility mapping by combining the three methods Fuzzy Logic, Frequency Ratio and Analytical Hierarchy Process in Dozain basin

    Directory of Open Access Journals (Sweden)

    E. Tazik

    2014-10-01

    Full Text Available Landslides are among the most important natural hazards that lead to modification of the environment. Therefore, studying of this phenomenon is so important in many areas. Because of the climate conditions, geologic, and geomorphologic characteristics of the region, the purpose of this study was landslide hazard assessment using Fuzzy Logic, frequency ratio and Analytical Hierarchy Process method in Dozein basin, Iran. At first, landslides occurred in Dozein basin were identified using aerial photos and field studies. The influenced landslide parameters that were used in this study including slope, aspect, elevation, lithology, precipitation, land cover, distance from fault, distance from road and distance from river were obtained from different sources and maps. Using these factors and the identified landslide, the fuzzy membership values were calculated by frequency ratio. Then to account for the importance of each of the factors in the landslide susceptibility, weights of each factor were determined based on questionnaire and AHP method. Finally, fuzzy map of each factor was multiplied to its weight that obtained using AHP method. At the end, for computing prediction accuracy, the produced map was verified by comparing to existing landslide locations. These results indicate that the combining the three methods Fuzzy Logic, Frequency Ratio and Analytical Hierarchy Process method are relatively good estimators of landslide susceptibility in the study area. According to landslide susceptibility map about 51% of the occurred landslide fall into the high and very high susceptibility zones of the landslide susceptibility map, but approximately 26 % of them indeed located in the low and very low susceptibility zones.

  16. A Dynamic Programming Model for Optimizing Frequency of Time-Lapse Seismic Monitoring in Geological CO2 Storage

    Science.gov (United States)

    Bhattacharjya, D.; Mukerji, T.; Mascarenhas, O.; Weyant, J.

    2005-12-01

    Designing a cost-effective and reliable monitoring program is crucial to the success of any geological CO2 storage project. Effective design entails determining both, the optimal measurement modality, as well as the frequency of monitoring the site. Time-lapse seismic provides the best spatial coverage and resolution for reservoir monitoring. Initial results from Sleipner (Norway) have demonstrated effective monitoring of CO2 plume movement. However, time-lapse seismic is an expensive monitoring technique especially over the long term life of a storage project and should be used judiciously. We present a mathematical model based on dynamic programming that can be used to estimate site-specific optimal frequency of time-lapse surveys. The dynamics of the CO2 sequestration process are simplified and modeled as a four state Markov process with transition probabilities. The states are M: injected CO2 safely migrating within the target zone; L: leakage from the target zone to the adjacent geosphere; R: safe migration after recovery from leakage state; and S: seepage from geosphere to the biosphere. The states are observed only when a monitoring survey is performed. We assume that the system may go to state S only from state L. We also assume that once observed to be in state L, remedial measures are always taken to bring it back to state R. Remediation benefits are captured by calculating the expected penalty if CO2 seeped into the biosphere. There is a trade-off between the conflicting objectives of minimum discounted costs of performing the next time-lapse survey and minimum risk of seepage and its associated costly consequences. A survey performed earlier would spot the leakage earlier. Remediation methods would have been utilized earlier, resulting in savings in costs attributed to excessive seepage. On the other hand, there are also costs for the survey and remedial measures. The problem is solved numerically using Bellman's optimality principal of dynamic

  17. Predictive factors of adherence to frequency and duration components in home exercise programs for neck and low back pain: an observational study

    Directory of Open Access Journals (Sweden)

    Jimeno-Serrano Francisco J

    2009-12-01

    Full Text Available Abstract Background Evidence suggests that to facilitate physical activity sedentary people may adhere to one component of exercise prescriptions (intensity, duration or frequency without adhering to other components. Some experts have provided evidence for determinants of adherence to different components among healthy people. However, our understanding remains scarce in this area for patients with neck or low back pain. The aims of this study are to determine whether patients with neck or low back pain have different rates of adherence to exercise components of frequency per week and duration per session when prescribed with a home exercise program, and to identify if adherence to both exercise components have distinct predictive factors. Methods A cohort of one hundred eighty-four patients with chronic neck or low back pain who attended physiotherapy in eight primary care centers were studied prospectively one month after intervention. The study had three measurement periods: at baseline (measuring characteristics of patients and pain, at the end of physiotherapy intervention (measuring characteristics of the home exercise program and a month later (measuring professional behaviors during clinical encounters, environmental factors and self-efficacy, and adherence behavior. Results Adherence to duration per session (70.9% ± 7.1 was more probable than adherence to frequency per week (60.7% ± 7.0. Self-efficacy was a relevant factor for both exercise components (p Conclusion We have shown in a clinic-based study that adherence to exercise prescription frequency and duration components have distinct levels and predictive factors. We recommend additional study, and advise that differential attention be given in clinical practice to each exercise component for improving adherence.

  18. An OFDM Receiver with Frequency Domain Diversity Combined Impulsive Noise Canceller for Underwater Network

    Science.gov (United States)

    Saotome, Rie; Hai, Tran Minh; Matsuda, Yasuto; Suzuki, Taisaku; Wada, Tomohisa

    2015-01-01

    In order to explore marine natural resources using remote robotic sensor or to enable rapid information exchange between ROV (remotely operated vehicles), AUV (autonomous underwater vehicle), divers, and ships, ultrasonic underwater communication systems are used. However, if the communication system is applied to rich living creature marine environment such as shallow sea, it suffers from generated Impulsive Noise so-called Shrimp Noise, which is randomly generated in time domain and seriously degrades communication performance in underwater acoustic network. With the purpose of supporting high performance underwater communication, a robust digital communication method for Impulsive Noise environments is necessary. In this paper, we propose OFDM ultrasonic communication system with diversity receiver. The main feature of the receiver is a newly proposed Frequency Domain Diversity Combined Impulsive Noise Canceller. The OFDM receiver utilizes 20–28 KHz ultrasonic channel and subcarrier spacing of 46.875 Hz (MODE3) and 93.750 Hz (MODE2) OFDM modulations. In addition, the paper shows Impulsive Noise distribution data measured at a fishing port in Okinawa and at a barge in Shizuoka prefectures and then proposed diversity OFDM transceivers architecture and experimental results are described. By the proposed Impulsive Noise Canceller, frame bit error rate has been decreased by 20–30%. PMID:26351656

  19. An OFDM Receiver with Frequency Domain Diversity Combined Impulsive Noise Canceller for Underwater Network.

    Science.gov (United States)

    Saotome, Rie; Hai, Tran Minh; Matsuda, Yasuto; Suzuki, Taisaku; Wada, Tomohisa

    2015-01-01

    In order to explore marine natural resources using remote robotic sensor or to enable rapid information exchange between ROV (remotely operated vehicles), AUV (autonomous underwater vehicle), divers, and ships, ultrasonic underwater communication systems are used. However, if the communication system is applied to rich living creature marine environment such as shallow sea, it suffers from generated Impulsive Noise so-called Shrimp Noise, which is randomly generated in time domain and seriously degrades communication performance in underwater acoustic network. With the purpose of supporting high performance underwater communication, a robust digital communication method for Impulsive Noise environments is necessary. In this paper, we propose OFDM ultrasonic communication system with diversity receiver. The main feature of the receiver is a newly proposed Frequency Domain Diversity Combined Impulsive Noise Canceller. The OFDM receiver utilizes 20-28 KHz ultrasonic channel and subcarrier spacing of 46.875 Hz (MODE3) and 93.750 Hz (MODE2) OFDM modulations. In addition, the paper shows Impulsive Noise distribution data measured at a fishing port in Okinawa and at a barge in Shizuoka prefectures and then proposed diversity OFDM transceivers architecture and experimental results are described. By the proposed Impulsive Noise Canceller, frame bit error rate has been decreased by 20-30%.

  20. An OFDM Receiver with Frequency Domain Diversity Combined Impulsive Noise Canceller for Underwater Network

    Directory of Open Access Journals (Sweden)

    Rie Saotome

    2015-01-01

    Full Text Available In order to explore marine natural resources using remote robotic sensor or to enable rapid information exchange between ROV (remotely operated vehicles, AUV (autonomous underwater vehicle, divers, and ships, ultrasonic underwater communication systems are used. However, if the communication system is applied to rich living creature marine environment such as shallow sea, it suffers from generated Impulsive Noise so-called Shrimp Noise, which is randomly generated in time domain and seriously degrades communication performance in underwater acoustic network. With the purpose of supporting high performance underwater communication, a robust digital communication method for Impulsive Noise environments is necessary. In this paper, we propose OFDM ultrasonic communication system with diversity receiver. The main feature of the receiver is a newly proposed Frequency Domain Diversity Combined Impulsive Noise Canceller. The OFDM receiver utilizes 20–28 KHz ultrasonic channel and subcarrier spacing of 46.875 Hz (MODE3 and 93.750 Hz (MODE2 OFDM modulations. In addition, the paper shows Impulsive Noise distribution data measured at a fishing port in Okinawa and at a barge in Shizuoka prefectures and then proposed diversity OFDM transceivers architecture and experimental results are described. By the proposed Impulsive Noise Canceller, frame bit error rate has been decreased by 20–30%.

  1. Masking of Time-Frequency Patterns in Applications of Passive Underwater Target Detection

    Directory of Open Access Journals (Sweden)

    Jüri Sildam

    2010-01-01

    Full Text Available Spectrogram analysis of acoustical sounds for underwater target classification is utilized when loud nonstationary interference sources overlap with a signal of interest in time but can be separated in time-frequency (TF domain. We propose a signal masking method which in a TF plane combines local statistical and morphological features of the signal of interest. A dissimilarity measure D of adjacent TF cells is used for local estimation of entropy H, followed by estimation of ΔH=Htc−Hfc entropy difference, where Hfc is calculated along the time axis at a mean frequency fc and Htc is calculated along the frequency axis at a mean time tc of the TF window, respectively. Due to a limited number of points used in ΔH estimation, the number of possible ΔH values, which define a primary mask, is also limited. A secondary mask is defined using morphological operators applied to, for example, H and ΔH. We demonstrate how primary and secondary masks can be used for signal detection and discrimination, respectively. We also show that the proposed approach can be generalized within the framework of Genetic Programming.

  2. [Clinical efficacy of high-frequency oscillatory ventilation combined with pulmonary surfactant in treatment of neonatal pulmonary hemorrhage].

    Science.gov (United States)

    Lin, Xin-Zhu; Lai, Ji-Dong; Lv, Mei; Zhu, Yao; Wang, Lian; Chen, Chao

    2015-04-01

    To explore the clinical efficacy of high-frequency oscillatory ventilation (HFOV) combined with pulmonary surfactant (PS) in the treatment of neonatal pulmonary hemorrhage (NPH). A total of 122 neonates diagnosed with NPH between January 2010 and June 2014 were enrolled. After being stratified by gestational age, the neonates were randomly divided into treatment (HFOV+PS) and control (HFOV alone) groups (n=61 each). Both groups were treated with HFOV after the onset of NPH. After 2-4 hours of HFOV treatment, the treatment group received PS via intratracheal injections, followed by continuous use of HFOV. Dynamic changes in the blood gas, oxygenation index (OI), and PaO2/FiO2 (P/F) values of the neonates were determined before HFOV treatment and after 6, 12, and 24 hours of HFOV treatment. The time to hemostasis, duration of ventilation, incidence of complications, and cure rate were compared between groups. After 6, 12, and 24 hours of HFOV treatment, the treatment group had significantly improved PaO2, PaCO2, O/I, and P/F values compared with the control group (P0.05). HFOV combined with PS is an effective treatment to improve oxygenation, shorten the time to hemostasis and the duration of ventilation, and reduce the incidence of complications in neonates with NPH. However, the dual therapy is unable to reduce the mortality of neonates compared with HFOV monotherapy.

  3. Treatment for snoring. Combined weight loss, sleeping on side, and nasal spray.

    Science.gov (United States)

    Braver, H M; Block, A J; Perri, M G

    1995-05-01

    We sought to find a combination of noninvasive treatments for snoring by adding weight loss to previously studied treatments, including the combination of sleeping on one's side and using a decongestant nasal spray. Twenty asymptomatic men who snore heavily were studied previously on a control night and on a night when they slept on their side and used a nasal spray. With these two treatments, minor improvements in apnea/hypopnea index (AHI) were seen, but no improvement occurred in snoring frequency. Nineteen of these subjects subsequently completed a 6-month weight loss program, and 12 lost weight. These 19 subjects comprise the study population of this report. At the conclusion of the weight loss program, a repeated sleep study was done from which the effect of adding weight loss to the two previously studied treatments could be assessed. Those 12 subjects who lost any amount of weight showed a very mild reduction in snores per hour from 328 using two modalities of treatment to 232 per hour with the addition of weight loss (p = 0.15). The nine subjects who lost > or = 3 kg reduced the number of snores per hour from 320 to 176 (p = 0.0496). Three subjects losing an average of only 7.6 kg showed virtual elimination of snoring after weight loss. Subjects who gained weight had no improvement in snoring. Weight loss added to the other two modalities of treatment had no effect on the AHI. In most cases, the combination of weight loss, sleeping on one's side, and the administration of a nasal decongestant significantly reduces the frequency of snoring in asymptomatic men who snore heavily. The major effect appears to be related to weight loss.

  4. Ionospheric Gradient Threat Mitigation in Future Dual Frequency GBAS

    Directory of Open Access Journals (Sweden)

    Michael Felux

    2017-01-01

    Full Text Available The Ground Based Augmentation System (GBAS is a landing system for aircraft based on differential corrections for the signals of Global Navigation Satellite Systems (GNSS, such as GPS or Galileo. The main impact on the availability of current single frequency systems results from the necessary protection against ionospheric gradients. With the introduction of Galileo and the latest generation of GPS satellites, a second frequency is available for aeronautical navigation. Dual frequency methods allow forming of ionospheric free combinations of the signals, eliminating a large part of the ionospheric threats to GBAS. However, the combination of several signals increases the noise in the position solution and in the calculation of error bounds. We, therefore, developed a method to base positioning algorithms on single frequency measurements and use the second frequency only for monitoring purposes. In this paper, we describe a detailed derivation of the monitoring scheme and discuss its implications for the use in an aviation context.

  5. Combined multi-distance frequency domain and diffuse correlation spectroscopy system with simultaneous data acquisition and real-time analysis.

    Science.gov (United States)

    Carp, Stefan A; Farzam, Parisa; Redes, Norin; Hueber, Dennis M; Franceschini, Maria Angela

    2017-09-01

    Frequency domain near infrared spectroscopy (FD-NIRS) and diffuse correlation spectroscopy (DCS) have emerged as synergistic techniques for the non-invasive assessment of tissue health. Combining FD-NIRS oximetry with DCS measures of blood flow, the tissue oxygen metabolic rate can be quantified, a parameter more closely linked to underlying physiology and pathology than either NIRS or DCS estimates alone. Here we describe the first commercially available integrated instrument, called the "MetaOx", designed to enable simultaneous FD-NIRS and DCS measurements at rates of 10 + Hz, and offering real-time data evaluation. We show simultaneously acquired characterization data demonstrating performance equivalent to individual devices and sample in vivo measurements of pulsation resolved blood flow, forearm occlusion hemodynamic changes and muscle oxygen metabolic rate monitoring during stationary bike exercise.

  6. Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method

    Energy Technology Data Exchange (ETDEWEB)

    Wang Shumin; Duyn, Jeff H [Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, 10 Center Drive, 10/B1D728, Bethesda, MD 20892 (United States)

    2006-06-21

    We present the combined field integral equation (CFIE) method for analysing radio-frequency coil arrays in high-field magnetic resonance imaging (MRI). Three-dimensional models of coils and the human body were used to take into account the electromagnetic coupling. In the method of moments formulation, we applied triangular patches and the Rao-Wilton-Glisson basis functions to model arbitrarily shaped geometries. We first examined a rectangular loop coil to verify the CFIE method and also demonstrate its efficiency and accuracy. We then studied several eight-channel receive-only head coil arrays for 7.0 T SENSE functional MRI. Numerical results show that the signal dropout and the average SNR are two major concerns in SENSE coil array design. A good design should be a balance of these two factors.

  7. Solving Component Structural Dynamic Failures Due to Extremely High Frequency Structural Response on the Space Shuttle Program

    Science.gov (United States)

    Frady, Greg; Nesman, Thomas; Zoladz, Thomas; Szabo, Roland

    2010-01-01

    For many years, the capabilities to determine the root-cause failure of component failures have been limited to the analytical tools and the state of the art data acquisition systems. With this limited capability, many anomalies have been resolved by adding material to the design to increase robustness without the ability to determine if the design solution was satisfactory until after a series of expensive test programs were complete. The risk of failure and multiple design, test, and redesign cycles were high. During the Space Shuttle Program, many crack investigations in high energy density turbomachines, like the SSME turbopumps and high energy flows in the main propulsion system, have led to the discovery of numerous root-cause failures and anomalies due to the coexistences of acoustic forcing functions, structural natural modes, and a high energy excitation, such as an edge tone or shedding flow, leading the technical community to understand many of the primary contributors to extremely high frequency high cycle fatique fluid-structure interaction anomalies. These contributors have been identified using advanced analysis tools and verified using component and system tests during component ground tests, systems tests, and flight. The structural dynamics and fluid dynamics communities have developed a special sensitivity to the fluid-structure interaction problems and have been able to adjust and solve these problems in a time effective manner to meet budget and schedule deadlines of operational vehicle programs, such as the Space Shuttle Program over the years.

  8. Note: Digital laser frequency auto-locking for inter-satellite laser ranging.

    Science.gov (United States)

    Luo, Yingxin; Li, Hongyin; Yeh, Hsien-Chi

    2016-05-01

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  9. Note: Digital laser frequency auto-locking for inter-satellite laser ranging

    International Nuclear Information System (INIS)

    Luo, Yingxin; Yeh, Hsien-Chi; Li, Hongyin

    2016-01-01

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  10. Note: Digital laser frequency auto-locking for inter-satellite laser ranging

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Yingxin; Yeh, Hsien-Chi, E-mail: yexianji@mail.hust.edu.cn [MOE Key Laboratory of Fundamental Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China); Li, Hongyin [MOE Key Laboratory of Fundamental Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Automation, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2016-05-15

    We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

  11. A Unique Master's Program in Combined Nuclear Technology and Nuclear Chemistry at Chalmers University of Technology, Sweden

    International Nuclear Information System (INIS)

    Skarnemark, Gunnar; Allard, Stefan; Ekberg, Christian; Nordlund, Anders

    2009-01-01

    The need for engineers and scientists who can ensure safe and secure use of nuclear energy is large in Sweden and internationally. Chalmers University of Technology is therefore launching a new 2-year master's program in Nuclear Engineering, with start from the autumn of 2009. The program is open to Swedish and foreign students. The program starts with compulsory courses dealing with the basics of nuclear chemistry and physics, radiation protection, nuclear power and reactors, nuclear fuel supply, nuclear waste management and nuclear safety and security. There are also compulsory courses in nuclear industry applications and sustainable energy futures. The subsequent elective courses can be chosen freely but there is also a possibility to choose informal tracks that concentrate on nuclear chemistry or reactor technology and physics. The nuclear chemistry track comprises courses in e.g. chemistry of lanthanides, actinides and transactinides, solvent extraction, radioecology and radioanalytical chemistry and radiopharmaceuticals. The program is finished with a one semester thesis project. This is probably a unique master program in the sense of its combination of deep courses in both nuclear technology and nuclear chemistry.

  12. Oxide vapor distribution from a high-frequency sweep e-beam system

    Science.gov (United States)

    Chow, R.; Tassano, P. L.; Tsujimoto, N.

    1995-03-01

    Oxide vapor distributions have been determined as a function of operating parameters of a high frequency sweep e-beam source combined with a programmable sweep controller. We will show which parameters are significant, the parameters that yield the broadest oxide deposition distribution, and the procedure used to arrive at these conclusions. A design-of-experimental strategy was used with five operating parameters: evaporation rate, sweep speed, sweep pattern (pre-programmed), phase speed (azimuthal rotation of the pattern), profile (dwell time as a function of radial position). A design was chosen that would show which of the parameters and parameter pairs have a statistically significant effect on the vapor distribution. Witness flats were placed symmetrically across a 25 inches diameter platen. The stationary platen was centered 24 inches above the e-gun crucible. An oxide material was evaporated under 27 different conditions. Thickness measurements were made with a stylus profilometer. The information will enable users of the high frequency e-gun systems to optimally locate the source in a vacuum system and understand which parameters have a major effect on the vapor distribution.

  13. Combinations of Quality and Frequency of Immunization Activities to Stop and Prevent Poliovirus Transmission in the High-Risk Area of Northwest Nigeria.

    Directory of Open Access Journals (Sweden)

    Radboud J Duintjer Tebbens

    Full Text Available Frequent supplemental immunization activities (SIAs with the oral poliovirus vaccine (OPV represent the primary strategy to interrupt poliovirus transmission in the last endemic areas.Using a differential-equation based poliovirus transmission model tailored to high-risk areas in Nigeria, we perform one-way and multi-way sensitivity analyses to demonstrate the impact of different assumptions about routine immunization (RI and the frequency and quality of SIAs on population immunity to transmission and persistence or emergence of circulating vaccine-derived polioviruses (cVDPVs after OPV cessation.More trivalent OPV use remains critical to avoid serotype 2 cVDPVs. RI schedules with or without inactivated polio vaccine (IPV could significantly improve population immunity if coverage increases well above current levels in under-vaccinated subpopulations. Similarly, the impact of SIAs on overall population immunity and cVDPV risks depends on their ability to reach under-vaccinated groups (i.e., SIA quality. Lower SIA coverage in the under-vaccinated subpopulation results in a higher frequency of SIAs needed to maintain high enough population immunity to avoid cVDPVs after OPV cessation.National immunization program managers in northwest Nigeria should recognize the benefits of increasing RI and SIA quality. Sufficiently improving RI coverage and improving SIA quality will reduce the frequency of SIAs required to stop and prevent future poliovirus transmission. Better information about the incremental costs to identify and reach under-vaccinated children would help determine the optimal balance between spending to increase SIA and RI quality and spending to increase SIA frequency.

  14. Combinations of Quality and Frequency of Immunization Activities to Stop and Prevent Poliovirus Transmission in the High-Risk Area of Northwest Nigeria.

    Science.gov (United States)

    Duintjer Tebbens, Radboud J; Pallansch, Mark A; Wassilak, Steven G F; Cochi, Stephen L; Thompson, Kimberly M

    2015-01-01

    Frequent supplemental immunization activities (SIAs) with the oral poliovirus vaccine (OPV) represent the primary strategy to interrupt poliovirus transmission in the last endemic areas. Using a differential-equation based poliovirus transmission model tailored to high-risk areas in Nigeria, we perform one-way and multi-way sensitivity analyses to demonstrate the impact of different assumptions about routine immunization (RI) and the frequency and quality of SIAs on population immunity to transmission and persistence or emergence of circulating vaccine-derived polioviruses (cVDPVs) after OPV cessation. More trivalent OPV use remains critical to avoid serotype 2 cVDPVs. RI schedules with or without inactivated polio vaccine (IPV) could significantly improve population immunity if coverage increases well above current levels in under-vaccinated subpopulations. Similarly, the impact of SIAs on overall population immunity and cVDPV risks depends on their ability to reach under-vaccinated groups (i.e., SIA quality). Lower SIA coverage in the under-vaccinated subpopulation results in a higher frequency of SIAs needed to maintain high enough population immunity to avoid cVDPVs after OPV cessation. National immunization program managers in northwest Nigeria should recognize the benefits of increasing RI and SIA quality. Sufficiently improving RI coverage and improving SIA quality will reduce the frequency of SIAs required to stop and prevent future poliovirus transmission. Better information about the incremental costs to identify and reach under-vaccinated children would help determine the optimal balance between spending to increase SIA and RI quality and spending to increase SIA frequency.

  15. A High-Frequency Isolation (HFI Charging DC Port Combining a Front-End Three-Level Converter with a Back-End LLC Resonant Converter

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2017-09-01

    Full Text Available The high-frequency isolation (HFI charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC resonant converter. The DC output voltage can be maintained within the desired voltage range by the front-end converter. The electrical isolation can be realized by the back-end LLC converter, which has the bus converter function. According to the three-level topology, the low-voltage rating power devices can be adapted for half-voltage stress of the total DC grid, and the PWM phase-shift control can double the equivalent switching frequency to greatly reduce the filter volume. LLC resonant converters have advance characteristics of inverter-side zero-voltage-switching (ZVS and rectifier-side zero-current switching (ZCS. In particular, it can achieve better performance under quasi-resonant frequency mode. Additionally, the magnetizing current can be modified following different DC output voltages, which have the self-adaptation ZVS condition for decreasing the circulating current. Here, the principles of the proposed topology are analyzed in detail, and the design conditions of the three-level output filter and high-frequency isolation transformer are explored. Finally, a 20 kW prototype with the 760 V input and 200–500 V output are designed and tested. The experimental results are demonstrated to verify the validity and performance of this charging DC port system structure.

  16. Nonequilibrium atmospheric pressure plasma jet using a combination of 50 kHz/2 MHz dual-frequency power sources

    International Nuclear Information System (INIS)

    Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei; Wang, Xiao-Min; Yin, Gui-Qin; Dong, Chen-Zhong

    2013-01-01

    An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperature of atmospheric pressure plasma could also be obtained using dual-frequency excitation

  17. Combined sub-threshold dosages of phenobarbital and low-frequency stimulation effectively reduce seizures in amygdala-kindled rats.

    Science.gov (United States)

    Asgari, Azam; Semnanian, Saeed; Atapour, Nafiseh; Shojaei, Amir; Moradi, Homeira; Mirnajafi-Zadeh, Javad

    2014-08-01

    Low-frequency stimulation (LFS) is a potential therapy utilized in patients who do not achieve satisfactory control of seizures with pharmacological treatments. Here, we investigated the interaction between anticonvulsant effects of LFS and phenobarbital (a commonly used medicine) on amygdala-kindled seizures in rats. Animals were kindled by electrical stimulation of basolateral amygdala in a rapid manner (12 stimulations/day). Fully kindled animals randomly received one of the three treatment choices: phenobarbital (1, 2, 3, 4 and 8 mg/kg; i.p.; 30 min before kindling stimulation), LFS (one or 4 packages contained 100 or 200 monophasic square wave pulses, 0.1-ms pulse duration at 1 Hz, immediately before kindling stimulation) or a combination of both (phenobarbital at 3 mg/kg and LFS). Phenobarbital alone at the doses of 1, 2 and 3 mg/kg had no significant effect on the main seizure parameters. LFS application always produced anticonvulsant effects unless applied with the pattern of one package of 100 pulses, which is considered as non-effective. All the seizure parameters were significantly reduced when phenobarbital (3 mg/kg) was administered prior to the application of the non-effective pattern of LFS. Phenobarbital (3 mg/kg) also increased the anticonvulsant actions of the effective LFS pattern. Our results provide an evidence of a positive cumulative anticonvulsant effect of LFS and phenobarbital, suggesting a potential combination therapy at sub-threshold dosages of phenobarbital and LFS to achieve a satisfactory clinical effect.

  18. IMPACT OF DIET, EXERCISE AND DIET COMBINED WITH EXERCISE PROGRAMS ON PLASMA LIPOPROTEIN AND ADIPONECTIN LEVELS IN OBESE GIRLS

    Directory of Open Access Journals (Sweden)

    Omar Ben Ounis

    2008-12-01

    Full Text Available We studied the effect of three programs, diet restriction (D, individualized exercise training (E at the maximal lipid oxidation point (LIPOXmax and diet combined with exercise (D+E, on body mass, plasma lipoprotein and adiponectin levels in obese girls. Eighteen obese adolescents girls aged 12-14 years were studied. A longitudinal intervention was carried out, consisting of a two-month diet (D; -500 kcal·day-1, of individualized exercise (E; 4 days/week, 90 min·day-1 and of diet combined with exercise (D+E. Body mass, body mass index (BMI, body fat mass, waist circumference, substrate crossover point, LIPOXmax point, homeostasis model assessment (HOMA-IR index, fasting levels of lipids and circulatory adiponectin, were measured in all subjects before and after the program. In subjects of the D+E group, body mass, BMI, body fat mass, waist circumference, HOMA-IR, low-density lipoprotein cholesterol (LDL-C and total cholesterol / high-density lipoprotein cholesterol (TC/HDL-C ratio were significantly lower, and HDL-C and adiponectin were higher after the program than that of subjects in the D or E groups. Diet/exercise improved the ability to oxidize lipids during exercise (crossover point: + 18.5 ± 3.4 of % Wmax; p < 0.01 and fat oxidation rate at LIPOXmax: + 89.7 ± 19.7 mg·min-1; p < 0.01. In the D+E group, significant correlations were found between changes in body mass and adiponectin and between changes in the TC/HDL-C ratio and LIPOXmax. These findings show that the combined program of diet restriction and individualized exercise training at the LIPOXmax point is necessary to simultaneously improve body mass loss, adiponectin levels, as well as metabolic parameters, in obese girls

  19. K-Band Radio frequency Interference Survey of Southeastern Michigan

    DEFF Research Database (Denmark)

    Curry, Shannon; Ahlers, Michael Faursby; Elliot, Harvey

    2010-01-01

    The Radio frequency Interference Survey of Earth (RISE) is a new type of instrument used to survey and characterize the presence of Radio Frequency Interference (RFI) that can affect microwave radiometers. It consists of a combined microwave radiometer and kurtosis spectrometer with broad frequen...

  20. If Frisch is true - impacts of varying beam width, resolution, frequency combinations and beam overlap when retrieving liquid water content profiles

    Science.gov (United States)

    Küchler, N.; Kneifel, S.; Kollias, P.; Loehnert, U.

    2017-12-01

    Cumulus and stratocumulus clouds strongly affect the Earth's radiation budget and are a major uncertainty source in weather and climate prediction models. To improve and evaluate models, a comprehensive understanding of cloud processes is necessary and references are needed. Therefore active and passive microwave remote sensing of clouds can be used to derive cloud properties such as liquid water path and liquid water content (LWC), which can serve as a reference for model evaluation. However, both the measurements and the assumptions when retrieving physical quantities from the measurements involve uncertainty sources. Frisch et al. (1998) combined radar and radiometer observations to derive LWC profiles. Assuming their assumptions are correct, there will be still uncertainties regarding the measurement setup. We investigate how varying beam width, temporal and vertical resolutions, frequency combinations, and beam overlap of and between the two instruments influence the retrieval of LWC profiles. Especially, we discuss the benefit of combining vertically, high resolved radar and radiometer measurements using the same antenna, i.e. having ideal beam overlap. Frisch, A. S., G. Feingold, C. W. Fairall, T. Uttal, and J. B. Snider, 1998: On cloud radar and microwave radiometer measurements of stratus cloud liquid water profiles. J. Geophys. Res.: Atmos., 103 (18), 23 195-23 197, doi:0148-0227/98/98JD-01827509.00.

  1. Two frequency ICRF operation on TFTR

    International Nuclear Information System (INIS)

    Rogers, J.H.; Majeski, R.; Wilson, J.R.; Hosea, J.C.; Schilling, G.; Stevens, J.; Phillips, C.K.

    1993-01-01

    Modifications have been made recently to allow two of the ICRF antennas (bays L and M) on TFTR to operate at either of two frequencies, 43 MHz or 64 MHz. This was accomplished by lengthening the resonant loops (2Λ at 43 MHz, 3Λ at 64 MHz) and replacing the conventional quarter wave impedance transformers with a tapered impedance design. The other two antennas (bays K and N) will operate at a fixed frequency, 43 MHz. The two frequency operation will allow a combination of 3 He-minority and H-minority heating at near full field on TFTR. The higher frequency, 64 MHz, may also be useful in direct electron heating and current drive experiments at lower toroidal fields. Models of the antenna, resonant loops and impedance matching system are presented

  2. 33 CFR 86.13 - Combined whistle systems.

    Science.gov (United States)

    2010-07-01

    ... systems. (a) A combined whistle system is a number of whistles (sound emitting sources) operated together... evidenced by at least two-thirds of the whistles in the combined system having fundamental frequencies... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Combined whistle systems. 86.13...

  3. Primary Frequency Response with Aggregated DERs: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Guggilam, Swaroop S.; Dhople, Sairaj V.; Zhao, Changhong; Dall' Anese, Emiliano; Chen, Yu Christine

    2017-03-03

    Power networks have to withstand a variety of disturbances that affect system frequency, and the problem is compounded with the increasing integration of intermittent renewable generation. Following a large-signal generation or load disturbance, system frequency is arrested leveraging primary frequency control provided by governor action in synchronous generators. In this work, we propose a framework for distributed energy resources (DERs) deployed in distribution networks to provide (supplemental) primary frequency response. Particularly, we demonstrate how power-frequency droop slopes for individual DERs can be designed so that the distribution feeder presents a guaranteed frequency-regulation characteristic at the feeder head. Furthermore, the droop slopes are engineered such that injections of individual DERs conform to a well-defined fairness objective that does not penalize them for their location on the distribution feeder. Time-domain simulations for an illustrative network composed of a combined transmission network and distribution network with frequency-responsive DERs are provided to validate the approach.

  4. Combining heterogeneous features for colonic polyp detection in CTC based on semi-definite programming

    Science.gov (United States)

    Wang, Shijun; Yao, Jianhua; Petrick, Nicholas A.; Summers, Ronald M.

    2009-02-01

    Colon cancer is the second leading cause of cancer-related deaths in the United States. Computed tomographic colonography (CTC) combined with a computer aided detection system provides a feasible combination for improving colonic polyps detection and increasing the use of CTC for colon cancer screening. To distinguish true polyps from false positives, various features extracted from polyp candidates have been proposed. Most of these features try to capture the shape information of polyp candidates or neighborhood knowledge about the surrounding structures (fold, colon wall, etc.). In this paper, we propose a new set of shape descriptors for polyp candidates based on statistical curvature information. These features, called histogram of curvature features, are rotation, translation and scale invariant and can be treated as complementing our existing feature set. Then in order to make full use of the traditional features (defined as group A) and the new features (group B) which are highly heterogeneous, we employed a multiple kernel learning method based on semi-definite programming to identify an optimized classification kernel based on the combined set of features. We did leave-one-patient-out test on a CTC dataset which contained scans from 50 patients (with 90 6-9mm polyp detections). Experimental results show that a support vector machine (SVM) based on the combined feature set and the semi-definite optimization kernel achieved higher FROC performance compared to SVMs using the two groups of features separately. At a false positive per patient rate of 7, the sensitivity on 6-9mm polyps using the combined features improved from 0.78 (Group A) and 0.73 (Group B) to 0.82 (p<=0.01).

  5. Effect of Training Frequency on Maximum Expiratory Pressure

    Science.gov (United States)

    Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine

    2012-01-01

    Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…

  6. The Frequency of Assistant Principal Coursework in Educational Leadership Programs

    Science.gov (United States)

    James, Stephanie

    2017-01-01

    The purpose of this study was to determine the extent to which the assistant principalship is addressed in educational leadership program curricula through coursework in state-approved programs operating in a southern state in the United States. A survey was administered to Educational Leadership program directors, and gaps were found between what…

  7. Triple-Frequency GPS Precise Point Positioning Ambiguity Resolution Using Dual-Frequency Based IGS Precise Clock Products

    Directory of Open Access Journals (Sweden)

    Fei Liu

    2017-01-01

    Full Text Available With the availability of the third civil signal in the Global Positioning System, triple-frequency Precise Point Positioning ambiguity resolution methods have drawn increasing attention due to significantly reduced convergence time. However, the corresponding triple-frequency based precise clock products are not widely available and adopted by applications. Currently, most precise products are generated based on ionosphere-free combination of dual-frequency L1/L2 signals, which however are not consistent with the triple-frequency ionosphere-free carrier-phase measurements, resulting in inaccurate positioning and unstable float ambiguities. In this study, a GPS triple-frequency PPP ambiguity resolution method is developed using the widely used dual-frequency based clock products. In this method, the interfrequency clock biases between the triple-frequency and dual-frequency ionosphere-free carrier-phase measurements are first estimated and then applied to triple-frequency ionosphere-free carrier-phase measurements to obtain stable float ambiguities. After this, the wide-lane L2/L5 and wide-lane L1/L2 integer property of ambiguities are recovered by estimating the satellite fractional cycle biases. A test using a sparse network is conducted to verify the effectiveness of the method. The results show that the ambiguity resolution can be achieved in minutes even tens of seconds and the positioning accuracy is in decimeter level.

  8. A Bayesian Analysis of the Flood Frequency Hydrology Concept

    Science.gov (United States)

    2016-02-01

    ERDC/CHL CHETN-X-1 February 2016 Approved for public release; distribution is unlimited. A Bayesian Analysis of the Flood Frequency Hydrology ...flood frequency hydrology concept as a formal probabilistic-based means by which to coherently combine and also evaluate the worth of different types...and development. INTRODUCTION: Merz and Blöschl (2008a,b) proposed the concept of flood frequency hydrology , which emphasizes the importance of

  9. Beat frequency ultrasonic microsphere contrast agent detection system

    Science.gov (United States)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  10. Demand as Frequency Controlled Reserve

    DEFF Research Database (Denmark)

    Xu, Zhao; Togeby, Mikael; Østergaard, Jacob

    This report summaries the research outcomes of the project ‘Demand as Frequency Controlled Reserve (DFR)’, which has received the support from Energinet.dk’s PSO program, Grant no. 2005-2-6380. The objective of this project is to investigate the technology of using electricity demands for providing...

  11. Combined effect of oxygen deficient point defects and Ni doping in radio frequency magnetron sputtering deposited ZnO thin films

    Energy Technology Data Exchange (ETDEWEB)

    Saha, B., E-mail: biswajit.physics@gmail.com [Thin Film and Nano Science Laboratory, Department of Physics, Jadavpur University, 700 032 Kolkata (India); Department of Physics, National Institute of Technology Agartala, Jirania 799046, Tripura (India); Das, N.S.; Chattopadhyay, K.K. [Thin Film and Nano Science Laboratory, Department of Physics, Jadavpur University, 700 032 Kolkata (India)

    2014-07-01

    Ni doped ZnO thin films with oxygen deficiency have been synthesized on glass substrates by radio frequency magnetron sputtering technique using argon plasma. The combined effect of point defects generated due to oxygen vacancies and Ni doping on the optical and electrical properties of ZnO thin films has been studied in this work. Ni doping concentrations were varied and the structural, optical and electrical properties of the films were studied as a function of doping concentrations. The films were characterized with X-ray diffractometer, UV–Vis–NIR spectrophotometer, X-ray photoelectron spectroscopy, atomic force microscopy and electrical conductivity measurements. Oxygen deficient point defects (Schottky defects) made the ZnO thin film highly conducting while incorporation of Ni dopant made it more functional regarding their electrical and optical properties. The films were found to have tunable electrical conductivity with Ni doping concentrations. - Highlights: • ZnO thin films prepared by radio frequency magnetron sputtering technique • Synthesis process was stimulated to introduce Schottky-type point defects. • Point defects and external doping of Ni made ZnO thin films more functional. • Point defect induced high electrical conductivity in ZnO thin film. • Significant shift in optical bandgap observed in ZnO with Ni doping concentrations.

  12. Modeling and Assessment of Precise Time Transfer by Using BeiDou Navigation Satellite System Triple-Frequency Signals

    Science.gov (United States)

    Zhang, Pengfei; Zhang, Rui; Liu, Jinhai; Lu, Xiaochun

    2018-01-01

    This study proposes two models for precise time transfer using the BeiDou Navigation Satellite System triple-frequency signals: ionosphere-free (IF) combined precise point positioning (PPP) model with two dual-frequency combinations (IF-PPP1) and ionosphere-free combined PPP model with a single triple-frequency combination (IF-PPP2). A dataset with a short baseline (with a common external time frequency) and a long baseline are used for performance assessments. The results show that IF-PPP1 and IF-PPP2 models can both be used for precise time transfer using BeiDou Navigation Satellite System (BDS) triple-frequency signals, and the accuracy and stability of time transfer is the same in both cases, except for a constant system bias caused by the hardware delay of different frequencies, which can be removed by the parameter estimation and prediction with long time datasets or by a priori calibration. PMID:29596330

  13. Using a Combination of FEM and Perturbation Method in Frequency Split Calculation of a Nearly Axisymmetric Shell with Middle Surface Shape Defect

    Directory of Open Access Journals (Sweden)

    D. S. Vakhlyarskiy

    2016-01-01

    Full Text Available This paper proposes a method to calculate the splitting of natural frequency of the shell of hemispherical resonator gyro. (HRG. The paper considers splitting that arises from the small defect of the middle surface, which makes the resonator different from the rotary shell. The presented method is a combination of the perturbation method and the finite element method. The method allows us to find the frequency splitting caused by defects in shape, arbitrary distributed in the circumferential direction. This is achieved by calculating the perturbations of multiple natural frequencies of the second and higher orders. The proposed method allows us to calculate the splitting of multiple frequencies for the shell with the meridian of arbitrary shape.A developed finite element is an annular element of the shell and has two nodes. Projections of movements are used on the axis of the global cylindrical system of coordinates, as the unknown. To approximate the movements are used polynomials of the second degree. Within the finite element the geometric characteristics are arranged in a series according to the small parameter of perturbations of the middle surface geometry.Movements on the final element are arranged in series according to the small parameter, and in a series according to circumferential angle. With computer used to implement the method, three-dimensional arrays are used to store the perturbed quantities. This allows the use of regular expressions for the mass and stiffness matrices, when building the finite element, instead of analytic dependencies for each perturbation of these matrices of the required order with desirable mathematical operations redefined in accordance with the perturbation method.As a test task, is calculated frequency splitting of non-circular cylindrical resonator with Navier boundary conditions. The discrepancy between the results and semi-analytic solution to this problem is less than 1%. For a cylindrical shell is

  14. 77 FR 39194 - Combined Drug and Alcohol Testing Programs

    Science.gov (United States)

    2012-07-02

    .... Revise paragraph (c)(5) and redesignate it as (c)(6); Sec. 120.115 Employee Assistance Program (EAP... assistance program (EAP). Finally, this rulemaking would make it clear that the agency's practice of... of the training given to both supervisors and employees in their employee assistance programs...

  15. 78 FR 41999 - Combined Drug and Alcohol Testing Programs

    Science.gov (United States)

    2013-07-15

    ...)(5) and (c)(6). The revisions read as follows: Sec. 120.115 Employee Assistance Program (EAP... of employees, must be documented as part of each employer's employee assistance program. 4. It makes... documentation of the training given to both supervisors and employees in their employee assistance programs...

  16. Modulator noise suppression in the LISA time-delay interferometric combinations

    International Nuclear Information System (INIS)

    Tinto, Massimo; Armstrong, J W; Estabrook, Frank B

    2008-01-01

    Laser Interferometer Space Antenna (LISA) is a mission to detect and study low-frequency cosmic gravitational radiation through its influence on the phases of six modulated laser beams exchanged between three remote spacecraft. We previously showed how the measurements of some 18 time series of relative frequency or phase shifts could be combined (1) to cancel the phase noise of the lasers, (2) to cancel the Doppler fluctuations due to non-inertial motions of the six optical benches and (3) to remove the phase noise of the onboard reference oscillators required to track the photodetector fringes, all the while preserving signals from passing gravitational waves. Here we analyze the effect of the additional noise due to the optical modulators used for removing the phase fluctuations of the onboard reference oscillators. We use the recently measured noise spectrum of an individual modulator (Klipstein et al 2006 Proc. 6th Int. LISA Symp. (Greenbelt, MA) (AIP Conf. Proc. vol 873) ed S M Merkowitz and J C Livas pp 19-23) to quantify the contribution of modulator noise to the first and second-generation time-delay interferometric (TDI) combinations as a function of the modulation frequency. We show that modulator noise can be made smaller than the expected proof-mass acceleration and optical-path noises if the modulation frequencies are larger than ∼682 MHz in the case of the unequal-arm Michelson TDI combination X 1 , ∼ 1.08 GHz for the Sagnac TDI combination α 1 , and ∼706 MHz for the symmetrical Sagnac TDI combination ζ 1 . These modulation frequencies are substantially smaller than previously estimated and may lead to less stringent requirements on the LISA's oscillator noise calibration subsystem. The measurements in Klipstein et al were performed in a laboratory experiment for a range of modulation frequencies, but we emphasize that, for the reference oscillator noise calibration algorithm to work, the modulation frequencies must be equal to the

  17. FREQUENCY COMPONENT EXTRACTION OF HEARTBEAT CUES WITH SHORT TIME FOURIER TRANSFORM (STFT

    Directory of Open Access Journals (Sweden)

    Sumarna Sumarna

    2017-01-01

      Electro-acoustic human heartbeat detector have been made with the main parts : (a stetoscope (piece chest, (b mic condenser, (c transistor amplifier, and (d cues analysis program with MATLAB. The frequency components that contained in heartbeat. cues have also been extracted with Short Time Fourier Transform (STFT from 9 volunteers. The results of the analysis showed that heart rate appeared in every cue frequency spectrum with their harmony. The steps of the research were including detector instrument design, test and instrument repair, cues heartbeat recording with Sound Forge 10 program and stored in wav file ; cues breaking at the start and the end, and extraction/cues analysis using MATLAB. The MATLAB program included filter (bandpass filter with bandwidth between 0.01 – 110 Hz, cues breaking with hamming window and every part was calculated using Fourier Transform (STFT mechanism and the result were shown in frequency spectrum graph.   Keywords: frequency components extraction, heartbeat cues, Short Time Fourier Transform

  18. The many places of frequency: evidence for a novel locus of the lexical frequency effect in word production.

    Science.gov (United States)

    Knobel, Mark; Finkbeiner, Matthew; Caramazza, Alfonso

    2008-03-01

    The effect of lexical frequency on language-processing tasks is exceptionally reliable. For example, pictures with higher frequency names are named faster and more accurately than those with lower frequency names. Experiments with normal participants and patients strongly suggest that this production effect arises at the level of lexical access. Further work has suggested that within lexical access this effect arises at the level of lexical representations. Here we present patient E.C. who shows an effect of lexical frequency on his nonword error rate. The best explanation of his performance is that there is an additional locus of frequency at the interface of lexical and segmental representational levels. We confirm this hypothesis by showing that only computational models with frequency at this new locus can produce a similar error pattern to that of patient E.C. Finally, in an analysis of a large group of Italian patients, we show that there exist patients who replicate E.C.'s pattern of results and others who show the complementary pattern of frequency effects on semantic error rates. Our results combined with previous findings suggest that frequency plays a role throughout the process of lexical access.

  19. Effectiveness of the Vital Aging program to promote active aging in Mexican older adults.

    Science.gov (United States)

    Mendoza-Ruvalcaba, Neyda Ma; Fernández-Ballesteros, Rocío

    2016-01-01

    Aging is not only a population phenomenon but also an experience and an individual reality. Vital Aging ® is a program that considers active aging as the lifelong adaptation process of maximizing health and independence, physical and cognitive functioning, positive affect regulation and control, and social engagement. Through its different versions and editions, it has demonstrated being an effective program to promote active aging. The aim of this study is to determine the effectiveness of the "face-to-face" and "combined" versions of the program to promote active aging in Mexican older adults trial. Seventy-six older adults aged 60 years and over participated in a quasi-experimental study and were recruited in a senior center to participate in the two experimental conditions: Vital Aging face-to-face (VA-FF) (n=35) and Vital Aging combined (VA-C; multimedia/face-to-face) (n=15), and the remaining 26 adults were assigned to a control group. Pretest and posttest assessments were performed after the theoretical-practical intervention. Mean differences and size effects were calculated for estimating the effect of the program. At the end of the study, participants showed improvements in the active aging outcome measures. Positive effects were observed in the frequency of intellectual, cultural - artistic, and social activities, perceptions of aging, satisfaction with social relationships, and self-efficacy for aging. Additionally, those who participated in VA-FF showed better memory performance, meta-memory, and a trend to report less memory problems, while older persons in VA-C showed a trend to have better life satisfaction. No effects were observed in physical activity, frequency of social relationships, and subjective health. Findings show that the Vital Aging program in face-to-face and combined versions encourages active aging in Mexican older persons. These results are in general similar to those found in editions performed in Spain, revealing its consistency

  20. Time-Frequency Analysis of Non-Stationary Biological Signals with Sparse Linear Regression Based Fourier Linear Combiner

    Directory of Open Access Journals (Sweden)

    Yubo Wang

    2017-06-01

    Full Text Available It is often difficult to analyze biological signals because of their nonlinear and non-stationary characteristics. This necessitates the usage of time-frequency decomposition methods for analyzing the subtle changes in these signals that are often connected to an underlying phenomena. This paper presents a new approach to analyze the time-varying characteristics of such signals by employing a simple truncated Fourier series model, namely the band-limited multiple Fourier linear combiner (BMFLC. In contrast to the earlier designs, we first identified the sparsity imposed on the signal model in order to reformulate the model to a sparse linear regression model. The coefficients of the proposed model are then estimated by a convex optimization algorithm. The performance of the proposed method was analyzed with benchmark test signals. An energy ratio metric is employed to quantify the spectral performance and results show that the proposed method Sparse-BMFLC has high mean energy (0.9976 ratio and outperforms existing methods such as short-time Fourier transfrom (STFT, continuous Wavelet transform (CWT and BMFLC Kalman Smoother. Furthermore, the proposed method provides an overall 6.22% in reconstruction error.

  1. Time-Frequency Analysis of Non-Stationary Biological Signals with Sparse Linear Regression Based Fourier Linear Combiner.

    Science.gov (United States)

    Wang, Yubo; Veluvolu, Kalyana C

    2017-06-14

    It is often difficult to analyze biological signals because of their nonlinear and non-stationary characteristics. This necessitates the usage of time-frequency decomposition methods for analyzing the subtle changes in these signals that are often connected to an underlying phenomena. This paper presents a new approach to analyze the time-varying characteristics of such signals by employing a simple truncated Fourier series model, namely the band-limited multiple Fourier linear combiner (BMFLC). In contrast to the earlier designs, we first identified the sparsity imposed on the signal model in order to reformulate the model to a sparse linear regression model. The coefficients of the proposed model are then estimated by a convex optimization algorithm. The performance of the proposed method was analyzed with benchmark test signals. An energy ratio metric is employed to quantify the spectral performance and results show that the proposed method Sparse-BMFLC has high mean energy (0.9976) ratio and outperforms existing methods such as short-time Fourier transfrom (STFT), continuous Wavelet transform (CWT) and BMFLC Kalman Smoother. Furthermore, the proposed method provides an overall 6.22% in reconstruction error.

  2. Impact of frequency control on PWR

    International Nuclear Information System (INIS)

    Constantieux, Thierry; Gautier, Alain; Deat, Max.

    1979-01-01

    This paper deals with experimental data that were recorded at TIHANGE 1, a Belgo-French nuclear power reactor, while the plant was performing frequency control with no load regulation. Frequency control induces quasi-permanent reactor power variations, whose effects on the following equipment must be analyzed carefully: rod mechanisms, fuel cladding and pressurizer components. A comparison of the experimental data with calculations performed on a hybrid computer is presented, together with a brief description of the hybrid program, DELTA, which was developed by FRAMATOME

  3. Frequency-domain method for separating signal and noise

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new method for separation of signal and noise (SSN) is put forward. Frequency is redefined according to the features of signal and its derivative in the sampl ing time interval, thus double orthogonal basis (DOB) is constructed so that a signal can be precisely signified with a linear combination of low-frequency DOB . Under joint consideration in time domain (TD) and frequency domain (FD), a method on SSN with high accuracy is derived and a matched algorithm is designed and analyzed. This method is applicable to SSN in multiple frequency bands, and convenient in applying signal characteristics in TD and FD synthetically with highe raccuracy.

  4. Frequency-domain method for separating signal and noise

    Institute of Scientific and Technical Information of China (English)

    王正明; 段晓君

    2000-01-01

    A new method for separation of signal and noise (SSN) is put forward. Frequency is redefined according to the features of signal and its derivative in the sampling time interval, thus double orthogonal basis (DOB) is constructed so that a signal can be precisely signified with a linear combination of low-frequency DOB. Under joint consideration in time domain (TD) and frequency domain (FD), a method on SSN with high accuracy is derived and a matched algorithm is designed and analyzed. This method is applicable to SSN in multiple frequency bands, and convenient in applying signal characteristics in TD and FD synthetically with higher accuracy.

  5. Modeling and Assessment of Precise Time Transfer by Using BeiDou Navigation Satellite System Triple-Frequency Signals

    Directory of Open Access Journals (Sweden)

    Rui Tu

    2018-03-01

    Full Text Available This study proposes two models for precise time transfer using the BeiDou Navigation Satellite System triple-frequency signals: ionosphere-free (IF combined precise point positioning (PPP model with two dual-frequency combinations (IF-PPP1 and ionosphere-free combined PPP model with a single triple-frequency combination (IF-PPP2. A dataset with a short baseline (with a common external time frequency and a long baseline are used for performance assessments. The results show that IF-PPP1 and IF-PPP2 models can both be used for precise time transfer using BeiDou Navigation Satellite System (BDS triple-frequency signals, and the accuracy and stability of time transfer is the same in both cases, except for a constant system bias caused by the hardware delay of different frequencies, which can be removed by the parameter estimation and prediction with long time datasets or by a priori calibration.

  6. Multiscale investigation on the effects of additional weight bearing in combination with low-magnitude high-frequency vibration on bone quality of growing female rats.

    Science.gov (United States)

    Zhang, Tianlong; Gao, Jiazi; Fang, Juan; Gong, He

    2018-03-01

    This study aimed to explore the effects of additional weight bearing in combination with low-magnitude high-frequency vibration (LMHFV; 45 Hz, 0.3 g) on bone quality. One hundred twenty rats were randomly divided into ten groups; namely, sedentary (SED), additional weight bearing in which the rat wears a backpack whose weight is x% of the body weight (WBx; x = 5, 12, 19, 26), basic vibration (V), and additional weight bearing in combination with LMHFV in which the rat wears a backpack whose weight is x% of the body weight (Vx; x = 5, 12, 19, 26). The experiment was conducted for 12 weeks, 7 days per week, and 15 min per day. A three-point bending mechanical test, micro computed tomography, and a nanoindentation test were used. Serum samples were analyzed chemically. Failure load in V19 rats was significantly lower than that in SED rats (P bearing in combination with LMHFV negatively affected the macromechanical properties and microarchitecture of bone. Heavy additional weight bearing, such as 26% of body weight, in combination with LMHFV was able to improve the nanomechanical properties of growing bone material compared with LMHFV. A combined mechanical stimulation was used, which may provide useful information to understand the mechanism of this mechanical stimulation on bone.

  7. Combining semantics with non-standard interpreter hierarchies

    DEFF Research Database (Denmark)

    Abramov, Sergei M.; Glück, Robert

    2000-01-01

    This paper reports on results concerning the combination of non-standard semantics via interpreters. We define what a semantics combination means and identify under which conditions a combination can be realized by computer programs (robustness, safely combinable). We develop the underlying mathe...... mathematical theory and examine the meaning of several non-standard interpreter towers. Our results suggest a technique for the implementation of a certain class of programming language dialects by composing a hierarchy of non-standard interpreters....

  8. Dimensions of flow during an experiential wilderness science program

    Science.gov (United States)

    Wang, Robert

    Over the past twenty-five years, there has been an alarming decline in academic performance among American students. This trend is seen in failing test scores, poor attendance, and low first-year retention rates at post-secondary institutions. There have been numerous studies that have examined this issue but few to offer solutions. Mihalyi Csikszentmihalyi, the originator of flow theory, suggests that poor academic performance might be best explained in terms of lack of student motivation and engagement (flow) rather than a lack of cognitive abilities. This study was designed to examine a series of activities conducted during an Experiential Wilderness Science Program at a college located in the Rocky Mountain region. Specifically, this study measured student engagement for each activity and described the dimensions (phenomenological, instructional, etc.) that were present when there was a high frequency of engagement among program participants. A combined quantitative and qualitative research methodology was utilized. The Experience Sampling Form (ESF) was administered to 41 freshman students participating in a 3-day wilderness science program to measure the frequency of engagement (flow) for nine different activities. A qualitative investigation using journals, participant interviews, and focus groups was used to describe the dimensions that were present when a high frequency of engagement among program participants was observed. Results revealed that engagement (flow) was highest during two challenge education activities and during a river sampling activity. Dimensions common among these activities included: an environment dimension, a motivation dimension, and an instruction dimension. The environment dimension included: incorporating novel learning activities, creating student interests, and introducing an element of perceived risk. The motivation dimension included: developing internal loci of control, facilitating high levels of self-efficacy, and

  9. The effect of a combined high-intensity plyometric and speed training program on the running and jumping ability of male handball players.

    Science.gov (United States)

    Cherif, Monsef; Said, Mohamed; Chaatani, Sana; Nejlaoui, Olfa; Gomri, Daghbaji; Abdallah, Aouidet

    2012-03-01

    The aim of this study was to investigate the effect of a combined program including sprint repetitions and drop jump training in the same session on male handball players. Twenty-two male handball players aged more than 20 years were assigned into 2 groups: experimental group (n=11) and control group (n=11). Selection was based on variables "axis" and "lines", goalkeepers were not included. The experimental group was subjected to 2 testing periods (test and retest) separated by 12 weeks of an additional combined plyometric and running speed training program. The control group performed the usual handball training. The testing period comprised, at the first day, a medical checking, anthropometric measurements and an incremental exercise test called yo-yo intermittent recovery test. 2 days later, participants performed the Repeated Sprint Ability test (RSA), and performed the Jumping Performance using 3 different events: Squat jump (SJ), Countermovement jump without (CMJ) and with arms (CMJA), and Drop jump (DJ). At the end of the training period, participants performed again the repeated sprint ability test, and the jumping performance. The conventional combined program improved the explosive force ability of handball players in CMJ (P=0.01), CMJA (P=0.01) and DJR (P=0.03). The change was 2.78, 2.42 and 2.62% respectively. No significant changes were noted in performances of the experimental group at the squat jump test and the drop jump with the left leg test. The training intervention also improved the running speed ability of the experimental group (P=0.003). No statistical differences were observed between lines or axes. Additional combined training program between sprint repetition and vertical jump in the same training session positively influence the jumping ability and the sprint ability of handball players.

  10. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Science.gov (United States)

    Windl, Roman; Abert, Claas; Bruckner, Florian; Huber, Christian; Vogler, Christoph; Weitensfelder, Herbert; Suess, Dieter

    2017-11-01

    Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  11. Contactless and absolute linear displacement detection based upon 3D printed magnets combined with passive radio-frequency identification

    Directory of Open Access Journals (Sweden)

    Roman Windl

    2017-11-01

    Full Text Available Within this work a passive and wireless magnetic sensor, to monitor linear displacements, is proposed. We exploit recent advances in 3D printing and fabricate a polymer bonded magnet with a spatially linear magnetic field component corresponding to the length of the magnet. Regulating the magnetic compound fraction during printing allows specific shaping of the magnetic field distribution. A giant magnetoresistance magnetic field sensor is combined with a radio-frequency identification tag in order to passively monitor the exerted magnetic field of the printed magnet. Due to the tailored magnetic field, a displacement of the magnet with respect to the sensor can be detected within the sub-mm regime. The sensor design provides good flexibility by controlling the 3D printing process according to application needs. Absolute displacement detection using low cost components and providing passive operation, long term stability, and longevity renders the proposed sensor system ideal for structural health monitoring applications.

  12. Association between the frequency of meals combining "Shushoku, Shusai, and Hukusai" (Staple food, main dish, and side dish) and intake of nutrients and food groups among Japanese young adults aged 18-24 years: a cross-sectional study.

    Science.gov (United States)

    Kakutani, Yuya; Kamiya, Saori; Omi, Naomi

    2015-01-01

    "Shushoku," "Shusai," and "Hukusai" are staple food, main dish, and side dish, respectively. The recommended meal in Japan is a combination of "Shushoku," "Shusai," and "Hukusai"; however, it remains unclear whether there is an association between the frequency of these meals and intake of nutrients and food groups. This cross-sectional study examined the association between the frequency of meals combining "Shushoku, Shusai, and Hukusai" and intake of nutrients and food groups among 664 Japanese young adults aged 18-24 y. The dietary habits of the subjects during the preceding month were assessed using a validated brief-type self-administered diet history questionnaire. The frequency of meals combining "Shushoku, Shusai, and Hukusai" was self-reported according to four categories: "less than 1 d or 1 d/wk," "2 or 3 d/wk," "4 or 5 d/wk," and "every day." In both women and men, there was an association between the higher frequency of these meals and higher intake of the following food groups: pulses, green and yellow vegetables, other vegetables, mushrooms, seaweeds, fish and shellfish, and eggs. Moreover, there was an association with higher intake of protein, polyunsaturated fat, n-6 and n-3 polyunsaturated fat, total dietary fiber, soluble and insoluble dietary fiber, β-carotene, α-tocopherol, vitamin K, thiamin, riboflavin, folate, pantothenic acid, vitamin C, potassium, calcium, magnesium, iron, and copper, and lower intake of carbohydrate in both women and men. Our findings support the hypothesis that the meals combining "Shushoku, Shusai, and Hukusai" may be associated with intake of many food groups and nutrients among Japanese young adults.

  13. The Effect of Docetaxel-Loaded Micro-Bubbles Combined with Low-Frequency Ultrasound in H22 Hepatocellular Carcinoma-Bearing Mice.

    Science.gov (United States)

    Ren, Shu-Ting; Shen, Shu; He, Xin-Ying; Liao, Yi-Ran; Sun, Peng-Fei; Wang, Bing; Zhao, Wen-Bao; Han, Shui-Ping; Wang, Yi-Li; Tian, Tian

    2016-02-01

    A novel lipid micro-bubble (MB) loaded with docetaxel (DOC-MB) was investigated in a previous study. However, its anti-tumor effects and mechanism of action in combination with low-frequency ultrasound (LFUS) in vivo are still unclear. DOC-MBs containing 5.0 mg of DOC were prepared by lyophilization with modification via ultrasonic emulsification. Then, the effects of DOC-MBs combined with LFUS on tumor growth, proliferating cell nuclear antigen (PCNA) expression and cell apoptosis, as well as local DOC delivery, were investigated in H22 hepatocellular carcinoma (HCC)-bearing mice. Compared with the previously prepared DOC-MBs (1.6 mg of DOC loaded), the encapsulation efficiency (81.2% ± 3.89%) and concentration ([7.94 ± 0.04] × 10(9) bubbles/mL) of the DOC-MBs containing 5.0 mg of DOC were higher, but the bubble size (1.368 ± 0.004 μm) was smaller. After treatment with the DOC-MBs and LFUS, the H22 HCC growth inhibition rate was significantly increased, PCNA expression in tumor tissue was significantly inhibited and local release of DOC was induced. In conclusion, new DOC-MBs containing 5.0 mg of DOC were successfully prepared with a high encapsulation efficiency and superior bubble size and concentration, and their combination with LFUS significantly enhanced the anti-tumor effect of DOC in H22 HCC-bearing mice by inhibiting tumor cell proliferation and increasing local drug delivery. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Efficient power combiner for THz radiation

    Energy Technology Data Exchange (ETDEWEB)

    Seidfaraji, Hamide, E-mail: hsfaraji@unm.edu; Fuks, Mikhail I.; Christodoulou, Christos; Schamiloglu, Edl [Department of Electrical and Computer Engineering, University of New Mexico, Albuquerque, NM, 87131-0001 (United States)

    2016-08-15

    Most dangerous explosive materials, both toxic and radioactive, contain nitrogen salts with resonant absorption lines in the frequency range 0.3-10 THz. Therefore, there has been growing interest in remotely detecting such materials by observing the spectrum of reflected signals when the suspicious material is interrogated by THz radiation. Practical portable THz sources available today generate only 20–40 mW output power. This power level is too low to interrogate suspicious material from a safe distance, especially if the material is concealed. Hence, there is a need for sources that can provide greater power in the THz spectrum. Generating and extracting high output power from THz sources is complicated and inefficient. The efficiency of vacuum electronic microwave sources is very low when scaled to the THz range and THz sources based on scaling down semiconductor laser sources have low efficiency as well, resulting in the well known “THz gap.” The reason for such low efficiencies for both source types is material losses in the THz band. In this article an efficient power combiner is described that is based on scaling to higher frequencies a microwave combiner that increases the output power in the THz range of interest in simulation studies. The proposed power combiner not only combines the THz power output from several sources, but can also form a Gaussian wavebeam output. A minimum conversion efficiency of 89% with cophased inputs in a lossy copper power combiner and maximum efficiency of 100% in a Perfect Electric Conductor (PEC)-made power combiner were achieved in simulations. Also, it is shown that the TE{sub 01} output mode is a reasonable option for THz applications due to the fact that conductive loss decreases for this mode as frequency increases.

  15. Efficient power combiner for THz radiation

    Directory of Open Access Journals (Sweden)

    Hamide Seidfaraji

    2016-08-01

    Full Text Available Most dangerous explosive materials, both toxic and radioactive, contain nitrogen salts with resonant absorption lines in the frequency range 0.3-10 THz. Therefore, there has been growing interest in remotely detecting such materials by observing the spectrum of reflected signals when the suspicious material is interrogated by THz radiation. Practical portable THz sources available today generate only 20–40 mW output power. This power level is too low to interrogate suspicious material from a safe distance, especially if the material is concealed. Hence, there is a need for sources that can provide greater power in the THz spectrum. Generating and extracting high output power from THz sources is complicated and inefficient. The efficiency of vacuum electronic microwave sources is very low when scaled to the THz range and THz sources based on scaling down semiconductor laser sources have low efficiency as well, resulting in the well known “THz gap.” The reason for such low efficiencies for both source types is material losses in the THz band. In this article an efficient power combiner is described that is based on scaling to higher frequencies a microwave combiner that increases the output power in the THz range of interest in simulation studies. The proposed power combiner not only combines the THz power output from several sources, but can also form a Gaussian wavebeam output. A minimum conversion efficiency of 89% with cophased inputs in a lossy copper power combiner and maximum efficiency of 100% in a Perfect Electric Conductor (PEC-made power combiner were achieved in simulations. Also, it is shown that the TE01 output mode is a reasonable option for THz applications due to the fact that conductive loss decreases for this mode as frequency increases.

  16. Providing frequency regulation reserve services using demand response scheduling

    International Nuclear Information System (INIS)

    Motalleb, Mahdi; Thornton, Matsu; Reihani, Ehsan; Ghorbani, Reza

    2016-01-01

    Highlights: • Proposing a market model for contingency reserve services using demand response. • Considering transient limitations of grid frequency for inverter-based generations. • Price-sensitive scheduling of residential batteries and water heaters using dynamic programming. • Calculating the profits of both generation companies and demand response aggregators. - Abstract: During power grid contingencies, frequency regulation is a primary concern. Historically, frequency regulation during contingency events has been the sole responsibility of the power utility. We present a practical method of using distributed demand response scheduling to provide frequency regulation during contingency events. This paper discusses the implementation of a control system model for the use of distributed energy storage systems such as battery banks and electric water heaters as a source of ancillary services. We present an algorithm which handles the optimization of demand response scheduling for normal operation and during contingency events. We use dynamic programming as an optimization tool. A price signal is developed using optimal power flow calculations to determine the locational marginal price of electricity, while sensor data for water usage is also collected. Using these inputs to dynamic programming, the optimal control signals are given as output. We assume a market model in which distributed demand response resources are sold as a commodity on the open market and profits from demand response aggregators as brokers of distributed demand response resources can be calculated. In considering control decisions for regulation of transient changes in frequency, we focus on IEEE standard 1547 in order to prevent the safety shut-off of inverter-based generation and further exacerbation of frequency droop. This method is applied to IEEE case 118 as a demonstration of the method in practice.

  17. Enhanced UXO Discrimination Using Frequency-Domain Electromagnetic Induction

    National Research Council Canada - National Science Library

    Nelson, H. H; Steinhurst, D. A; Barrow, B; Bell, T; Khadar, N; SanFilipo, B; Won, I. J

    2007-01-01

    .... With support from the Environmental Security Technology Certification Program, we have developed a frequency-domain electromagnetic induction sensor array to extend the discrimination capabilities of the MTADS...

  18. Simulation of a combined-cycle engine

    Science.gov (United States)

    Vangerpen, Jon

    1991-01-01

    A FORTRAN computer program was developed to simulate the performance of combined-cycle engines. These engines combine features of both gas turbines and reciprocating engines. The computer program can simulate both design point and off-design operation. Widely varying engine configurations can be evaluated for their power, performance, and efficiency as well as the influence of altitude and air speed. Although the program was developed to simulate aircraft engines, it can be used with equal success for stationary and automative applications.

  19. Frequency locking of an extended-cavity quantum cascade laser to a frequency comb for precision mid infrared spectroscopy

    KAUST Repository

    Alsaif, Bidoor; Lamperti, Marco; Gatti, Davide; Laporta, Paolo; Fermann, Martin E.; Farooq, Aamir; Marangoni, Marco

    2017-01-01

    Extended-cavity quantum cascade lasers (EC-QCLs) enable mode-hope-free frequency sweeps in the mid-infrared region over ranges in excess of 100 cm−1, at speeds up to 1 THz/s and with a 100-mW optical power level. This makes them ideally suited for broadband absorption spectroscopy and for the simultaneous detection of multiple gases. On the other hand, their use for precision spectroscopy has been hampered so far by a large amount of frequency noise, resulting in an optical linewidth of about 30 MHz over 50 ms [1]. This is one of the reasons why neither their frequency nor their phase have been so far locked to a frequency comb. Their use in combination with frequency combs has been performed in an open loop regime only [2], which has the merit of preserving the inherently fast modulation speed of these lasers, yet not to afford high spectral resolution and accuracy.

  20. Frequency locking of an extended-cavity quantum cascade laser to a frequency comb for precision mid infrared spectroscopy

    KAUST Repository

    Alsaif, Bidoor

    2017-11-02

    Extended-cavity quantum cascade lasers (EC-QCLs) enable mode-hope-free frequency sweeps in the mid-infrared region over ranges in excess of 100 cm−1, at speeds up to 1 THz/s and with a 100-mW optical power level. This makes them ideally suited for broadband absorption spectroscopy and for the simultaneous detection of multiple gases. On the other hand, their use for precision spectroscopy has been hampered so far by a large amount of frequency noise, resulting in an optical linewidth of about 30 MHz over 50 ms [1]. This is one of the reasons why neither their frequency nor their phase have been so far locked to a frequency comb. Their use in combination with frequency combs has been performed in an open loop regime only [2], which has the merit of preserving the inherently fast modulation speed of these lasers, yet not to afford high spectral resolution and accuracy.

  1. Mechanical, tribological and corrosion properties of CrBN films deposited by combined direct current and radio frequency magnetron sputtering

    International Nuclear Information System (INIS)

    Jahodova, Vera; Ding, Xing-zhao; Seng, Debbie H.L.; Gulbinski, W.; Louda, P.

    2013-01-01

    Cr–B–N films were deposited on stainless steel substrates by a combined direct current and radio frequency (RF) reactive unbalanced magnetron sputtering process using two elemental Cr and one compound BN targets. Boron content in the as-deposited films was qualitatively analyzed by time-of-flight secondary ion mass spectroscopy. Films' microstructure, mechanical and tribological properties were characterized by X-ray diffraction, nanoindentation and pin-on-disk tribometer experiments. Corrosion behavior of the Cr–B–N films was evaluated by electrochemical potentiodynamic polarization method in a 3 wt.% NaCl solution. All the films were crystallized into a NaCl-type cubic structure. At lower RF power applied on the BN target (≤ 600 W), films are relatively randomly oriented, and films' crystallinity increased with increasing RF power. With increasing RF power further (≥ 800 W), films became (200) preferentially oriented, and films' crystallinity decreased gradually. With incorporation of a small amount of boron atoms into the CrN films, hardness, wear- and corrosion-resistance were all improved evidently. The best wear and corrosion resistance was obtained for the film deposited with 600 W RF power applied on the BN target. - Highlights: • CrBN films deposited by direct current and radio frequency magnetron sputtering. • CrBN exhibited higher hardness, wear- and corrosion-resistance than pure CrN. • The best wear- and corrosion-resistant film was deposited with 600 W RF power

  2. Effects of a combined parent-student alcohol prevention program on intermediate factors and adolescents' drinking behavior: A sequential mediation model.

    Science.gov (United States)

    Koning, Ina M; Maric, Marija; MacKinnon, David; Vollebergh, Wilma A M

    2015-08-01

    Previous work revealed that the combined parent-student alcohol prevention program (PAS) effectively postponed alcohol initiation through its hypothesized intermediate factors: increase in strict parental rule setting and adolescents' self-control (Koning, van den Eijnden, Verdurmen, Engels, & Vollebergh, 2011). This study examines whether the parental strictness precedes an increase in adolescents' self-control by testing a sequential mediation model. A cluster randomized trial including 3,245 Dutch early adolescents (M age = 12.68, SD = 0.50) and their parents randomized over 4 conditions: (1) parent intervention, (2) student intervention, (3) combined intervention, and (4) control group. Outcome measure was amount of weekly drinking measured at age 12 to 15; baseline assessment (T0) and 3 follow-up assessments (T1-T3). Main effects of the combined and parent intervention on weekly drinking at T3 were found. The effect of the combined intervention on weekly drinking (T3) was mediated via an increase in strict rule setting (T1) and adolescents' subsequent self-control (T2). In addition, the indirect effect of the combined intervention via rule setting (T1) was significant. No reciprocal sequential mediation (self-control at T1 prior to rules at T2) was found. The current study is 1 of the few studies reporting sequential mediation effects of youth intervention outcomes. It underscores the need of involving parents in youth alcohol prevention programs, and the need to target both parents and adolescents, so that change in parents' behavior enables change in their offspring. (c) 2015 APA, all rights reserved).

  3. The U.S. Marine Corps Combined Action Program (CAP): A Proposed Alternative Strategy for the Vietnam War

    Science.gov (United States)

    2002-05-01

    Vietnamese men abstained from premarital sex, they openly practiced mutual masturbation . 62 In western culture, a man’s business was a man’s business, but... practice of integrating Marine with native forces marked the beginning of a nearly six year endeavor entitled the Combined Action Program or CAP. Embraced...chain of command. While the CAP platoons drew from infantry battalions primarily, their ties to them remained administrative and informal in practice

  4. Accurate Natural Trail Detection Using a Combination of a Deep Neural Network and Dynamic Programming.

    Science.gov (United States)

    Adhikari, Shyam Prasad; Yang, Changju; Slot, Krzysztof; Kim, Hyongsuk

    2018-01-10

    This paper presents a vision sensor-based solution to the challenging problem of detecting and following trails in highly unstructured natural environments like forests, rural areas and mountains, using a combination of a deep neural network and dynamic programming. The deep neural network (DNN) concept has recently emerged as a very effective tool for processing vision sensor signals. A patch-based DNN is trained with supervised data to classify fixed-size image patches into "trail" and "non-trail" categories, and reshaped to a fully convolutional architecture to produce trail segmentation map for arbitrary-sized input images. As trail and non-trail patches do not exhibit clearly defined shapes or forms, the patch-based classifier is prone to misclassification, and produces sub-optimal trail segmentation maps. Dynamic programming is introduced to find an optimal trail on the sub-optimal DNN output map. Experimental results showing accurate trail detection for real-world trail datasets captured with a head mounted vision system are presented.

  5. Visceral and Somatic Disorders: Tissue Softening with Frequency-Specific Microcurrent

    OpenAIRE

    McMakin, Carolyn R.; Oschman, James L.

    2013-01-01

    Frequency-specific microcurrent (FSM) is an emerging technique for treating many health conditions. Pairs of frequencies of microampere-level electrical stimulation are applied to particular places on the skin of a patient via combinations of conductive graphite gloves, moistened towels, or gel electrode patches. A consistent finding is a profound and palpable tissue softening and warming within seconds of applying frequencies appropriate for treating particular conditions. Similar phenomena ...

  6. Laser frequency modulator for modulating a laser cavity

    Science.gov (United States)

    Erbert, Gaylen V.

    1992-01-01

    The present invention relates to a laser frequency modulator for modulating a laser cavity. It is known in the prior art to utilize a PZT (piezoelectric transducer) element in combination with a mirror to change the cavity length of a laser cavity (which changes the laser frequency). Using a PZT element to drive the mirror directly is adequate at frequencies below 10 kHz. However, in high frequency applications (100 kHz and higher) PZT elements alone do not provide a sufficient change in the cavity length. The present invention utilizes an ultrasonic concentrator with a PZT element and mirror to provide modulation of the laser cavity. With an ultrasonic concentrator, the mirror element at the end of a laser cavity can move at larger amplitudes and higher frequencies.

  7. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  8. Programs as Polypeptides.

    Science.gov (United States)

    Williams, Lance R

    2016-01-01

    Object-oriented combinator chemistry (OOCC) is an artificial chemistry with composition devices borrowed from object-oriented and functional programming languages. Actors in OOCC are embedded in space and subject to diffusion; since they are neither created nor destroyed, their mass is conserved. Actors use programs constructed from combinators to asynchronously update their own states and the states of other actors in their neighborhoods. The fact that programs and combinators are themselves reified as actors makes it possible to build programs that build programs from combinators of a few primitive types using asynchronous spatial processes that resemble chemistry as much as computation. To demonstrate this, OOCC is used to define a parallel, asynchronous, spatially distributed self-replicating system modeled in part on the living cell. Since interactions among its parts result in the construction of more of these same parts, the system is strongly constructive. The system's high normalized complexity is contrasted with that of a simple composome.

  9. A new algebraic white-noise modal combination rule - GAC(A)

    International Nuclear Information System (INIS)

    Mertens, P.G.

    1994-01-01

    It is a well known fact that above the rigid frequency the maximum dynamic modal responses even with different multiple supports can be combined algebraically. Below the rigid frequency, and more specifically in the white-noise (amplified) region of the response spectrum, algebraic modal combination is still a matter of controversy, demonstrated e.g. by the NRC R.G. 1.92 requirement to take the absolute values of the modal responses in heuristic modal combination rules; whereas algebraic support combination is only allowed in conjunction with the envelope support response spectrum (ERS). Such regulatory requirements can lead to unrealistically high calculated responses e.g. in the coupled analysis of light secondary systems attached to heavy primary structures and in the decoupled analysis of systems when the centres of mass and stiffness do not coincide, or when the ERS is used. A new Generalised Algebraic Combination (GAC) methodology has been theoretically developed which allows practical algebraic modal and support combination over the whole frequency range of multiple support spectra. The present paper deals with the GAC-(A) i.e. the modal combination version in the white noise region of a single response spectrum and more specifically its time history integration validation, which shows that this new modal combination rule can satisfy any realistic conservatism that may be required by regulatory institutions. (orig.)

  10. Application of frequency domain line edge roughness characterization methodology in lithography

    Science.gov (United States)

    Sun, Lei; Wang, Wenhui; Beique, Genevieve; Wood, Obert; Kim, Ryoung-Han

    2015-03-01

    A frequency domain 3 sigma LER characterization methodology combining the standard deviation and power spectral density (PSD) methods is proposed. In the new method, the standard deviation is calculated in the frequency domain instead of the spatial domain as in the conventional method. The power spectrum of the LER is divided into three regions: low frequency (LF), middle frequency (MF) and high frequency (HF) regions. The frequency region definition is based on process visual comparisons. Three standard deviation numbers are used to characterize the LER in the three frequency regions. Pattern wiggling can be detected quantitatively with a wiggling factor which is also proposed in this paper.

  11. Using frequency equivalency in stability calculations

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Temirbulatov, R.A.; Tereshko, L.A.

    1981-01-01

    A methodology for calculating oscillatory instability that involves using frequency equivalency is employed in carrying out the following proceedures: dividing an electric power system into subgroups; determining the adjustments to the automatic excitation control in each subsystem; simplifying the mathematical definition of the separate subsystems by using frequency equivalency; gradually re-tuning the automatic excitation control in the separate subsystems to account for neighboring subsystems by using their equivalent frequency characteristics. The methodology is to be used with a computer program to determine the gain in the stabilization channels of the automatic excitation control unit in which static stability of the entire aggregate of normal and post-breakdown conditions acceptable damping of transient processes are provided. The possibility of reducing the equation series to apply to chosen regions of the existing range of frequencies is demonstrated. The use of the methodology is illustrated in a sample study on stability in a Siberian unified power system.

  12. Frequency Domain Multiplexing for Use With NaI[Tl] Detectors

    Science.gov (United States)

    Belling, Samuel; Coherent Collaboration

    2017-09-01

    A process used in many forms of signal communication known as multiplexing is adapted for the purpose of combining signals from NaI[Tl] detectors so that fewer digitizer channels can be used to process the signal information from large experiments within the COHERENT collaboration. Each signal is passed through a ringing circuit to modulate it with a characteristic frequency. Information about the signal can be extracted from its amplitude, frequency, and phase. Simulations in LTSpice show that an operational amplifier circuit with a parallel LRC feedback loop can serve as the modulating circuit. Several such circuits can be constructed and housed compactly in a unit, and fed to an inverting, summing amplifier with tunable gain, such that the signals are carried by one cable. The signals are analyzed based on a Fourier transform after being digitized. The results show that the energy, channel, and time of the original interaction can be recovered by this process. In some cases it is possible through filtering and deconvolution to recover the shape of the original signal. The effort is ongoing, but with the design presented it is possible to multiplex 10 detectors into a single digitizer channel. NSF REU Program at Duke University.

  13. Investigation of the Relationship Between Electrical Stimulation Frequency and Muscle Frequency Response Under Submaximal Contractions.

    Science.gov (United States)

    Papcke, Caluê; Krueger, Eddy; Olandoski, Marcia; Nogueira-Neto, Guilherme Nunes; Nohama, Percy; Scheeren, Eduardo Mendonça

    2018-03-25

    Neuromuscular electrical stimulation (NMES) is a common tool that is used in clinical and laboratory experiments and can be combined with mechanomyography (MMG) for biofeedback in neuroprostheses. However, it is not clear if the electrical current applied to neuromuscular tissues influences the MMG signal in submaximal contractions. The objective of this study is to investigate whether the electrical stimulation frequency influences the mechanomyographic frequency response of the rectus femoris muscle during submaximal contractions. Thirteen male participants performed three maximal voluntary isometric contractions (MVIC) recorded in isometric conditions to determine the maximal force of knee extensors. This was followed by the application of nine modulated NMES frequencies (20, 25, 30, 35, 40, 45, 50, 75, and 100 Hz) to evoke 5% MVIC. Muscle behavior was monitored by the analysis of MMG signals, which were decomposed into frequency bands by using a Cauchy wavelet transform. For each applied electrical stimulus frequency, the mean MMG spectral/frequency response was estimated for each axis (X, Y, and Z axes) of the MMG sensor with the values of the frequency bands used as weights (weighted mean). Only with respect to the Z (perpendicular) axis of the MMG signal, the stimulus frequency of 20 Hz did not exhibit any difference with the weighted mean (P = 0.666). For the frequencies of 20 and 25 Hz, the MMG signal displayed the bands between 12 and 16 Hz in the three axes (P frequencies from 30 to 100 Hz, the muscle presented a higher concentration of the MMG signal between the 22 and 29 Hz bands for the X and Z axes, and between 16 and 34 Hz bands for the Y axis (P frequency, because their frequency contents tend to mainly remain between the 20- and 25-Hz bands. Hence, NMES does not interfere with the use of MMG in neuroprosthesis. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Nonlinear Modelling of Low Frequency Loudspeakers

    DEFF Research Database (Denmark)

    Olsen, Erling Sandermann

    1997-01-01

    In the Danish LoDist project on distortion from dynamic low frequency loudspeakers a detailed nonlinear model of loudspeakers has been developed. The model has been implemented in a PC program so that it can be used to create signals for listening tests and analysis. Also, different methods...

  15. Nonlinear Modelling of Low Frequency Loudspeakers

    DEFF Research Database (Denmark)

    Olsen, Erling Sandermann

    1997-01-01

    In the Danish LoDist project on distortion from dynamic low-frequency loudspeakers, a detailed nonlinear model of loudspeakers has been developed. The model has been implemented in a PC program so that it can be used to create signals for listening tests and analysis. Also, different methods...

  16. Validation of a simplified food frequency questionnaire for the assessment of dietary habits in Iranian adults: Isfahan Healthy Heart Program, Iran.

    Science.gov (United States)

    Mohammadifard, Noushin; Sajjadi, Firouzeh; Maghroun, Maryam; Alikhasi, Hassan; Nilforoushzadeh, Farzaneh; Sarrafzadegan, Nizal

    2015-03-01

    Dietary assessment is the first step of dietary modification in community-based interventional programs. This study was performed to validate a simple food frequency questionnaire (SFFQ) for assessment of selected food items in epidemiological studies with a large sample size as well as community trails. This validation study was carried out on 264 healthy adults aged ≥ 41 years old living in 3 district central of Iran, including Isfahan, Najafabad, and Arak. Selected food intakes were assessed using a 48-item food frequency questionnaire (FFQ). The FFQ was interviewer-administered, which was completed twice; at the beginning of the study and 2 weeks thereafter. The validity of this SFFQ was examined compared to estimated amount by single 24 h dietary recall and 2 days dietary record. Validation of the FFQ was determined using Spearman correlation coefficients between daily frequency consumption of food groups as assessed by the FFQ and the qualitative amount of daily food groups intake accessed by dietary reference method was applied to evaluate validity. Intraclass correlation coefficients (ICC) were used to determine the reproducibility. Spearman correlation coefficient between the estimated amount of food groups intake by examined and reference methods ranged from 0.105 (P = 0.378) in pickles to 0.48 (P studies and clinical trial with large participants.

  17. Signal noise/interferer combiner unit programmable (SINCUP)

    Science.gov (United States)

    Martinezdepison, Emilio

    1988-12-01

    The Signal Noise Interferer Combiner Unit Programmable (SINCUP) has been developed to facilitate laboratory performance testing of Very Low Frequency (VLF/Low Frequency (LF) receivers. To accomplish this, the unit allows the combining in controlled amounts of various real-world environmental and manmade interference with an information carrying signal. The externally modulated signal is combined with internally/externally generated Gaussian noise and/or with an internally/externally generated interferer. In order to test modern digital processing techniques, such as Adaptive Null Steering, Eigenvector Sorting, and Widrow-Hoff adaptive filters, SINCUP is capable of generating and meeting much higher signal-to-noise plus interference ratios than earlier channel simulators. The present software has been written to accommodate a dynamic signal-to-noise ratio (SNR) range from -60 to +60 dB. Higher dynamic range units could be implemented.

  18. Risk-based inservice testing program modifications at Palo Verde nuclear generating station

    International Nuclear Information System (INIS)

    Knauf, S.; Lindenlaub, B.; Linthicum, R.

    1996-01-01

    Arizona Public Service Company (APS) is investigating changes to the Palo Verde Inservice Testing (IST) Program that are intended to result in the reduction of the required test frequency for various valves in the American Society of Mechanical Engineers (ASME) Section XI IST program. The analytical techniques employed to select candidate valves and to demonstrate that these frequency reductions are acceptable are risk based. The results of the Palo Verde probabilistic risk assessment (PRA), updated in June 1994, and the risk significant determination performed as part of the implementation efforts for 10 CFR 50.65 (the maintenance rule) were used to select candidate valves for extended test intervals. Additional component level evaluations were conducted by an 'expert panel.' The decision to pursue these changes was facilitated by the ASME Risk-Based Inservice Testing Research Task Force for which Palo Verde is participating as a pilot plant. The NRC's increasing acceptance of cost beneficial licensing actions and risk-based submittals also provided incentive to seek these changes. Arizona Public Service is pursuing the risk-based IST program modification in order to reduce the unnecessary regulatory burden of the IST program through qualitative and quantitative analysis consistent with maintaining a high level of plant safety. The objectives of this project at Palo Verde are as follows: (1) Apply risk-based technologies to IST components to determine their risk significance (i.e., high or low). (2) Apply a combination of deterministic and risk-based methods to determine appropriate testing requirements for IST components including improvement of testing methods and frequency intervals for high-risk significant components. (3) Apply risk-based technologies to high-risk significant components identified by the open-quotes expert panelclose quotes and outside of the IST program to determine whether additional testing requirements are appropriate

  19. Risk-based inservice testing program modifications at Palo Verde nuclear generating station

    Energy Technology Data Exchange (ETDEWEB)

    Knauf, S.; Lindenlaub, B.; Linthicum, R.

    1996-12-01

    Arizona Public Service Company (APS) is investigating changes to the Palo Verde Inservice Testing (IST) Program that are intended to result in the reduction of the required test frequency for various valves in the American Society of Mechanical Engineers (ASME) Section XI IST program. The analytical techniques employed to select candidate valves and to demonstrate that these frequency reductions are acceptable are risk based. The results of the Palo Verde probabilistic risk assessment (PRA), updated in June 1994, and the risk significant determination performed as part of the implementation efforts for 10 CFR 50.65 (the maintenance rule) were used to select candidate valves for extended test intervals. Additional component level evaluations were conducted by an `expert panel.` The decision to pursue these changes was facilitated by the ASME Risk-Based Inservice Testing Research Task Force for which Palo Verde is participating as a pilot plant. The NRC`s increasing acceptance of cost beneficial licensing actions and risk-based submittals also provided incentive to seek these changes. Arizona Public Service is pursuing the risk-based IST program modification in order to reduce the unnecessary regulatory burden of the IST program through qualitative and quantitative analysis consistent with maintaining a high level of plant safety. The objectives of this project at Palo Verde are as follows: (1) Apply risk-based technologies to IST components to determine their risk significance (i.e., high or low). (2) Apply a combination of deterministic and risk-based methods to determine appropriate testing requirements for IST components including improvement of testing methods and frequency intervals for high-risk significant components. (3) Apply risk-based technologies to high-risk significant components identified by the {open_quotes}expert panel{close_quotes} and outside of the IST program to determine whether additional testing requirements are appropriate.

  20. Dynamics of Microbeams under Multi-Frequency Excitations

    KAUST Repository

    Ibrahim, Alwathiqbellah

    2017-01-24

    This paper presents an investigation of the dynamics of microbeams under multiple harmonic electrostatic excitation frequencies. First, the response of a cantilever microbeam to two alternating current (AC) source excitation is examined. We show by simulations the response of the microbeam at primary resonance (near the fundamental natural frequency) and at secondary resonances (near half, superharmonic, and twice, subharmonic, the fundamental natural frequency). A multimode Galerkin method combined with the Euler-Bernoulli beam equation, accounting for the nonlinear electrostatic force, has been used to develop a reduced order model. The response of the cantilever microbeam to three AC source excitation is also investigated and shown as a promising technique to enhance the bandwidth of resonators. Finally, an experimental study of a clamped-clamped microbeam is conducted, demonstrating the multi-frequency excitation resonances using two, three, and four AC sources.

  1. Dynamics of Microbeams under Multi-Frequency Excitations

    KAUST Repository

    Ibrahim, Alwathiqbellah; Jaber, Nizar; Chandran, Akhil; Thirupathi, Maloth; Younis, Mohammad I.

    2017-01-01

    This paper presents an investigation of the dynamics of microbeams under multiple harmonic electrostatic excitation frequencies. First, the response of a cantilever microbeam to two alternating current (AC) source excitation is examined. We show by simulations the response of the microbeam at primary resonance (near the fundamental natural frequency) and at secondary resonances (near half, superharmonic, and twice, subharmonic, the fundamental natural frequency). A multimode Galerkin method combined with the Euler-Bernoulli beam equation, accounting for the nonlinear electrostatic force, has been used to develop a reduced order model. The response of the cantilever microbeam to three AC source excitation is also investigated and shown as a promising technique to enhance the bandwidth of resonators. Finally, an experimental study of a clamped-clamped microbeam is conducted, demonstrating the multi-frequency excitation resonances using two, three, and four AC sources.

  2. MSWT-01, an alternative in combining Production Based Education (PBE) and student CSR program in Polman

    Science.gov (United States)

    Ananto, Gamawan; Setiawan, Albertus B.; Z, Darman M.

    2014-06-01

    MSWT-01, Mobile Surface Water Treatment, producing 1m3 per hour, is an alternative for providing clean water in flood disaster areas, and was developed at Bandung State Polytechnic for Manufacturing (Polman) as a part of institution research project. The combination of cartridge or membrane technology such as carbon block, MF, UF and filtration media is used for this machine, instead of coagulation-flocculation with chemical addition, due to emergency purposes related with its treatment processing time. The idea is that MSWT could be combined with Production Based Education (PBE) concept in Polman as a vocational education institution and students 'CSR', students social activities. With the number of implementation trials in real flood area condition, MSWT will be developed further based on the technical output result. The manufacturing process for improving or adding necessary features could be implemented as a student's project in PBE system. This might be an ideal combination alternative for such vocational institution that students get the product media for their PBE program and implement their work as a defined social activity. They will learn and experience related technical matters and more social interactions with the people and other disaster stakeholder as well.

  3. Analysis of Combined Data from Heterogeneous Study Designs: A Methodological Proposal from the Patient Navigation Research program

    Science.gov (United States)

    Roetzheim, Richard G.; Freund, Karen M.; Corle, Don K.; Murray, David M.; Snyder, Frederick R.; Kronman, Andrea C.; Jean-Pierre, Pascal; Raich, Peter C.; Holden, Alan E. C.; Darnell, Julie S.; Warren-Mears, Victoria; Patierno, Steven; Design, PNRP; Committee, Analysis

    2013-01-01

    Background The Patient Navigation Research Program (PNRP) is a cooperative effort of nine research projects, each employing its own unique study design. To evaluate projects such as PNRP, it is desirable to perform a pooled analysis to increase power relative to the individual projects. There is no agreed upon prospective methodology, however, for analyzing combined data arising from different study designs. Expert opinions were thus solicited from members of the PNRP Design and Analysis Committee Purpose To review possible methodologies for analyzing combined data arising from heterogeneous study designs. Methods The Design and Analysis Committee critically reviewed the pros and cons of five potential methods for analyzing combined PNRP project data. Conclusions were based on simple consensus. The five approaches reviewed included: 1) Analyzing and reporting each project separately, 2) Combining data from all projects and performing an individual-level analysis, 3) Pooling data from projects having similar study designs, 4) Analyzing pooled data using a prospective meta analytic technique, 5) Analyzing pooled data utilizing a novel simulated group randomized design. Results Methodologies varied in their ability to incorporate data from all PNRP projects, to appropriately account for differing study designs, and in their impact from differing project sample sizes. Limitations The conclusions reached were based on expert opinion and not derived from actual analyses performed. Conclusions The ability to analyze pooled data arising from differing study designs may provide pertinent information to inform programmatic, budgetary, and policy perspectives. Multi-site community-based research may not lend itself well to the more stringent explanatory and pragmatic standards of a randomized controlled trial design. Given our growing interest in community-based population research, the challenges inherent in the analysis of heterogeneous study design are likely to become

  4. Analysis of combined data from heterogeneous study designs: an applied example from the patient navigation research program.

    Science.gov (United States)

    Roetzheim, Richard G; Freund, Karen M; Corle, Don K; Murray, David M; Snyder, Frederick R; Kronman, Andrea C; Jean-Pierre, Pascal; Raich, Peter C; Holden, Alan Ec; Darnell, Julie S; Warren-Mears, Victoria; Patierno, Steven

    2012-04-01

    The Patient Navigation Research Program (PNRP) is a cooperative effort of nine research projects, with similar clinical criteria but with different study designs. To evaluate projects such as PNRP, it is desirable to perform a pooled analysis to increase power relative to the individual projects. There is no agreed-upon prospective methodology, however, for analyzing combined data arising from different study designs. Expert opinions were thus solicited from the members of the PNRP Design and Analysis Committee. To review possible methodologies for analyzing combined data arising from heterogeneous study designs. The Design and Analysis Committee critically reviewed the pros and cons of five potential methods for analyzing combined PNRP project data. The conclusions were based on simple consensus. The five approaches reviewed included the following: (1) analyzing and reporting each project separately, (2) combining data from all projects and performing an individual-level analysis, (3) pooling data from projects having similar study designs, (4) analyzing pooled data using a prospective meta-analytic technique, and (5) analyzing pooled data utilizing a novel simulated group-randomized design. Methodologies varied in their ability to incorporate data from all PNRP projects, to appropriately account for differing study designs, and to accommodate differing project sample sizes. The conclusions reached were based on expert opinion and not derived from actual analyses performed. The ability to analyze pooled data arising from differing study designs may provide pertinent information to inform programmatic, budgetary, and policy perspectives. Multisite community-based research may not lend itself well to the more stringent explanatory and pragmatic standards of a randomized controlled trial design. Given our growing interest in community-based population research, the challenges inherent in the analysis of heterogeneous study design are likely to become more salient

  5. Comparing the Effectiveness of Paroxetine, Attention Modification Program and Combination of both on Improving Social Anxiety Symptoms

    Directory of Open Access Journals (Sweden)

    Hosein Khedmatgozar

    2012-08-01

    Full Text Available Introduction: Although the effectiveness of paroxetine and Attention Modification Program has been studied separately in treating social anxiety disorder, there has been no research comparing them according to the literature. The aim of this study was to compare the effectiveness of paroxetine, Attention Modification Program (AMP and combination of both on improving the Social Anxiety Symptoms. Methods: 33 patients meeting DSM-IV-TR criteria for social anxiety disorder were randomly assigned in 3 groups: 11 in paroxetine group, 11 in AMP group and 11 in combined group. Treatment intervention was done during 8 weeks period. Social Phobia Inventory (SPIN, Beck Depression Inventory (BDI-II and Sheehan Disability Scale (SDS were administered before and after treatment intervention. One-way Analysis of Covariance (ANCOVA was used to determine the differences and efficacy of treatment interventions between groups. Data analysis was done by SPSS-16 software. Results: 28 participants completed the treatment period. One-way ANCOVA results showed statistically significant differences in post-treatment scores of social phobia (p=0/007, depressive symptoms (p=0.007 and daily life functioning (p=0.011 between three groups. Bonferroni correction showed that combined treatment is significantly more effective than AMP in reducing social phobia symptoms (p=0.007, depressive symptoms (p=0.022 and enhancing daily life functioning (0.019. Yet, there were no significant differences between Paroxetine and combined treatment in all post-treatment scores (p=0.890, p=1.000, p=1.000 for social phobia, depressive symptoms and daily life functioning respectively. Paroxetine showed more significant improvement of depressive symptoms (p=0.016 and enhancing daily life functioning (p=0.045 than AMP. Also, there were no significant differences between paroxetine and AMP in reducing social anxiety symptoms. Discussion: It seems that paroxetine has wider effect in reducing social

  6. Comparing the Effectiveness of Paroxetine, Attention Modification Program and Combination of both on Improving Social Anxiety Symptoms

    Directory of Open Access Journals (Sweden)

    Aliasghar Asgharnejad Farid

    2012-09-01

    Full Text Available Introduction: Although the effectiveness of paroxetine and Attention Modification Program has been studied separately in treating social anxiety disorder, there has been no research comparing them according to the literature. The aim of this study was to compare the effectiveness of paroxetine, Attention Modification Program (AMP and combination of both on improving the Social Anxiety Symptoms.Methods:33 patients meeting DSM-IV-TR criteria for social anxiety disorder were randomly assigned in 3 groups: 11 in paroxetine group, 11 in AMP group and 11 in combined group. Treatment intervention was done during 8 weeks period. Social Phobia Inventory (SPIN, Beck Depression Inventory (BDI-II and Sheehan Disability Scale (SDS were administered before and after treatment intervention. One-way Analysis of Covariance (ANCOVA was used to determine the differences and efficacy of treatment interventions between groups. Data analysis was done by SPSS-16 software.Results:28 participants completed the treatment period. One-way ANCOVA results showed statistically significant differences in post-treatment scores of social phobia (p=0/007, depressive symptoms (p=0.007 and daily life functioning (p=0.011 between three groups. Bonferroni correction showed that combined treatment is significantly more effective than AMP in reducing social phobia symptoms (p=0.007, depressive symptoms (p=0.022 and enhancing daily life functioning (0.019. Yet, there were no significant differences between Paroxetine and combined treatment in all post-treatment scores (p=0.890, p=1.000, p=1.000 for social phobia, depressive symptoms and daily life functioning respectively. Paroxetine showed more significant improvement of depressive symptoms (p=0.016 and enhancing daily life functioning (p=0.045 than AMP. Also, there were no significant differences between paroxetine and AMP in reducing social anxiety symptoms.Discussion:It seems that paroxetine has wider effect in reducing social

  7. An analysis of the combination frequencies of constituent medicinal herbs in prescriptions for the treatment of bone and joint disorder in Korean medicine: determination of a group of candidate prescriptions for universal use

    Directory of Open Access Journals (Sweden)

    Yoo Kyoung Han

    2017-12-01

    Full Text Available Background: This study aimed to select prescriptions (mixtures of medicinal herbs used in the treatment of bone and joint disorders in Korean medicine, and through the analysis of medicinal herb combination frequencies, select a high-frequency medicinal herb combination group for further experimental and clinical research. Methods: We systematically searched for terms related to bone and joint disorder in the “Dongeuibogam (Dong yibaojian”, a seminal Korean medicine book. We reviewed the results of published papers regarding the effects in bone and joint disorders (especially in osteoporosis, osteomalacia, osteopenia, rheumatoid arthritis, and degenerative arthritis. Results: In total, 34 candidates of a medicinal herb combination for the treatment of bone and joint disorders(CMHCTBJDs and nine candidates of a medicinal herb for the treatment of bone and joint disorders(CMHTBJDs were selected. Conclusion: : The candidates of a medicinal herb combination for the treatment of bone and joint disorders (CMHCTBJDs and candidates of a medicinal herb for the treatment of bone and joint disorders(CMHTBJDs proposed in this study can be useful material for text mining to develop natural products with the effects in BJDs and also it has the potential to reduce the experimental and developmental time period. Keywords: Dongeuibogam (Dong yi bao gian, Text mining, Bone disorder

  8. Personal computer versus personal computer/mobile device combination users' preclinical laboratory e-learning activity.

    Science.gov (United States)

    Kon, Haruka; Kobayashi, Hiroshi; Sakurai, Naoki; Watanabe, Kiyoshi; Yamaga, Yoshiro; Ono, Takahiro

    2017-11-01

    The aim of the present study was to clarify differences between personal computer (PC)/mobile device combination and PC-only user patterns. We analyzed access frequency and time spent on a complete denture preclinical website in order to maximize website effectiveness. Fourth-year undergraduate students (N=41) in the preclinical complete denture laboratory course were invited to participate in this survey during the final week of the course to track login data. Students accessed video demonstrations and quizzes via our e-learning site/course program, and were instructed to view online demonstrations before classes. When the course concluded, participating students filled out a questionnaire about the program, their opinions, and devices they had used to access the site. Combination user access was significantly more frequent than PC-only during supplementary learning time, indicating that students with mobile devices studied during lunch breaks and before morning classes. Most students had favorable opinions of the e-learning site, but a few combination users commented that some videos were too long and that descriptive answers were difficult on smartphones. These results imply that mobile devices' increased accessibility encouraged learning by enabling more efficient time use between classes. They also suggest that e-learning system improvements should cater to mobile device users by reducing video length and including more short-answer questions. © 2016 John Wiley & Sons Australia, Ltd.

  9. Phenomena induced by powerful HF pumping towards magnetic zenith with a frequency near the F-region critical frequency and the third electron gyro harmonic frequency

    Directory of Open Access Journals (Sweden)

    N. F. Blagoveshchenskaya

    2009-01-01

    Full Text Available Multi-instrument observational data from an experiment on 13 October 2006 at the EISCAT/HEATING facility at Tromsø, Norway are analysed. The experiment was carried out in the evening hours when the electron density in the F-region dropped, and the HF pump frequency fH was near and then above the critical frequency of the F2 layer. The distinctive feature of this experiment is that the pump frequency was just below the third electron gyro harmonic frequency, while both the HF pump beam and UHF radar beam were directed towards the magnetic zenith (MZ. The HF pump-induced phenomena were diagnosed with several instruments: the bi-static HF radio scatter on the London-Tromsø-St. Petersburg path, the CUTLASS radar in Hankasalmi (Finland, the European Incoherent Scatter (EISCAT UHF radar at Tromsø and the Tromsø ionosonde (dynasonde. The results show thermal electron excitation of the HF-induced striations seen simultaneously from HF bi-static scatter and CUTLASS radar observations, accompanied by increases of electron temperature when the heater frequency was near and then above the critical frequency of the F2 layer by up to 0.4 MHz. An increase of the electron density up to 25% accompanied by strong HF-induced electron heating was observed, only when the heater frequency was near the critical frequency and just below the third electron gyro harmonic frequency. It is concluded that the combined effect of upper hybrid resonance and gyro resonance at the same altitude gives rise to strong electron heating, the excitation of striations, HF ray trapping and extension of HF waves to altitudes where they can excite Langmuir turbulence and fluxes of electrons accelerated to energies that produce ionization.

  10. Phenomena induced by powerful HF pumping towards magnetic zenith with a frequency near the F-region critical frequency and the third electron gyro harmonic frequency

    Directory of Open Access Journals (Sweden)

    N. F. Blagoveshchenskaya

    2009-01-01

    Full Text Available Multi-instrument observational data from an experiment on 13 October 2006 at the EISCAT/HEATING facility at Tromsø, Norway are analysed. The experiment was carried out in the evening hours when the electron density in the F-region dropped, and the HF pump frequency fH was near and then above the critical frequency of the F2 layer. The distinctive feature of this experiment is that the pump frequency was just below the third electron gyro harmonic frequency, while both the HF pump beam and UHF radar beam were directed towards the magnetic zenith (MZ. The HF pump-induced phenomena were diagnosed with several instruments: the bi-static HF radio scatter on the London-Tromsø-St. Petersburg path, the CUTLASS radar in Hankasalmi (Finland, the European Incoherent Scatter (EISCAT UHF radar at Tromsø and the Tromsø ionosonde (dynasonde. The results show thermal electron excitation of the HF-induced striations seen simultaneously from HF bi-static scatter and CUTLASS radar observations, accompanied by increases of electron temperature when the heater frequency was near and then above the critical frequency of the F2 layer by up to 0.4 MHz. An increase of the electron density up to 25% accompanied by strong HF-induced electron heating was observed, only when the heater frequency was near the critical frequency and just below the third electron gyro harmonic frequency. It is concluded that the combined effect of upper hybrid resonance and gyro resonance at the same altitude gives rise to strong electron heating, the excitation of striations, HF ray trapping and extension of HF waves to altitudes where they can excite Langmuir turbulence and fluxes of electrons accelerated to energies that produce ionization.

  11. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  12. Population genetic data for six non-combined DNA index system ...

    African Journals Online (AJOL)

    The respective values for the combined power of exclusion in these populations were 0.94 and 0.99. The allele frequency data generated can be used for estimating DNA profile frequencies for the studied populations residing in South Africa. Key words: Allele frequencies, MiniSTR, DNA typing, population data, South Africa ...

  13. Imagining a Stata / Python Combination

    Science.gov (United States)

    Fiedler, James

    2012-01-01

    There are occasions when a task is difficult in Stata, but fairly easy in a more general programming language. Python is a popular language for a range of uses. It is easy to use, has many high ]quality packages, and programs can be written relatively quickly. Is there any advantage in combining Stata and Python within a single interface? Stata already offers support for user-written programs, which allow extensive control over calculations, but somewhat less control over graphics. Also, except for specifying output, the user has minimal programmatic control over the user interface. Python can be used in a way that allows more control over the interface and graphics, and in so doing provide a roundabout method for satisfying some user requests (e.g., transparency levels in graphics and the ability to clear the results window). My talk will explore these ideas, present a possible method for combining Stata and Python, and give examples to demonstrate how this combination might be useful.

  14. Status of efforts to evaluate LOCA frequency estimates using combined PRA and PFM approaches

    International Nuclear Information System (INIS)

    Wilkowski, G.; Rudland, D.; Tregoning, R.; Scott, P.

    2002-01-01

    The risk-informed reevaluation of 10 CFR 50.46 (along with Appendix K and GDC 35), the emergency core cooling system (ECCS) requirements, utilizes loss of coolant accident (LOCA) initiating event frequencies to evaluate the technical basis for potential related rule changes. A longer-term effort is considering redefining the maximum design basis pipe break size for sizing the ECCS system. In the past few years, the U.S. Nuclear Regulatory Commission (NRC) has utilized NUREG/CR-5750 pipe-break LOCA estimated for initiating event frequencies. However, several failure mechanisms have recently emerged at plants which have not been evident within the service period covered by the NUREG/CR-5750 estimates. The concern is that these and other potential aging-related mechanisms may not be adequately represented within the NUREG/CR-5750 LOCA estimates. Additionally, LOCAs can occur from failure of active components (e.g. safety relief valves, reactor coolant pump seals, etc.) and other non-pipe break passive failures (e.g. steam generator tubes). The LOCA contributions from these additional sources must also be considered in deciding the design basis break size. The LOCA estimates must also attempt to capture expected future changes in the LOCA frequencies so that the estimates are pertinent up through the end of the license renewal period. (orig.)

  15. Approach and results of the PWR low power and shutdown accident frequencies program - Coarse screening analysis for Surry

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Luckas, W.; Wong, S.M.; Fitzpatrick, R.G.

    1991-01-01

    Traditionally, probabilistic risk analyses of severe accidents in nuclear power plants have limited themselves to consideration of the set of initiating events occurring during full power operation. However, some analyses of accident initiators during low power, shutdown, and other modes of plant operation other than full power have been performed. These studies as well as the Chernobyl accident and recent operating experience at US pressurized water reactors (PWRs) suggested that risks during low power and shutdown could be significant. As such, the analysis of the frequencies, consequences, and risks of these accidents was identified as one task in the Nuclear Regulatory Commission staff's study of the implications of the Chernobyl accident to US commercial nuclear power plants. This program is an ongoing high priority effort at Brookhaven National Laboratory (BNL). The scope includes a Level 1 probabilistic risk assessment (PRA) with internal fire and flood for Surry Unit 1 (PWR). This program is also closely coupled to a parallel project for the Grand Gulf plant (BWWR) being conducted by SNL. The program is being performed in two phases. Phase 1 represents a coarse screening analysis to identify dominant accident scenarios as well as risk dominant plant configurations and plant operating states. In Phase 2, a detailed PRA will be performed for the dominant accident scenarios/operating states identified in Phase 1. The objectives, results and insights of Phase 1 are discussed in the paper

  16. Synergistic Role of Balanced Scorecard/Activity Based Costing and Goal Programming Combined Model on Strategic Cost Management

    OpenAIRE

    Taleghani, Mohammad

    2017-01-01

    During the past few years, we have seen a significant shift in cost accounting and management. In the new business environment, cost management has become a critical skill, but it is not sufficient for simply reducing costs; instead, costs must be managed strategically. Application of a successful Strategic Cost Management (StraCM) system plays the significant role in success of organization performance. In this study, we want to illustrate how the goal programming model in combination with t...

  17. Changes in selected physical, motor performance and anthropometric components of university-level rugby players after one microcycle of a combined rugby conditioning and plyometric training program.

    Science.gov (United States)

    Pienaar, Cindy; Coetzee, Ben

    2013-02-01

    The purpose of this study was to determine the effects of a microcycle (4 weeks) combined rugby conditioning plyometric compared with a nonplyometric rugby conditioning program on selected physical and motor performance components and anthropometric measurements of university-level rugby players. Players (18.94 ± 0.40 years) were assigned to either a control (n = 16) or experimental group (n = 19) from the U/19 rugby teams of the North-West University (South Africa). Twenty-six direct and indirect anthropometric measurements were taken, and the players performed a battery of 5 physical and motor performance tests before and after a microcycle (4 week) combined rugby conditioning plyometric (experimental group) and a nonplyometric rugby conditioning program (control group). The dependent t-test results showed that the control group's upper-body explosive power decreased significantly, whereas the stature, skeletal mass, and femur breadth increased significantly from pre- to posttesting. The experimental group showed significant increases in wrist breadth, speed over 20 m, agility, and power and work measurements of the Wingate anaerobic test (WAnT). Despite these results, the independent t-test revealed that speed over 20 m, average power output at 20 seconds, relative work of the WAnT, and agility were the only components of the experimental group that improved significantly more than the control group. A microcycle combined rugby conditioning plyometric program therefore leads to significantly bigger changes in selected physical and motor performance components of university-level rugby players than a nonplyometric rugby conditioning program alone. Based on these findings, coaches and sport scientists should implement 3 weekly combined rugby conditioning plyometric programs in rugby players' training regimens to improve the players' speed, agility, and power.

  18. Optical Transmitter Terminal for Selective RF High Frequency Bans

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent improvements in multiplexing systems and tunable laser semiconductor diodes make the use of Wavelength Division Multiplexing to combine multiple frequency...

  19. [COMBINED IMMUNOTHERAPY OF RECONDITIONAL CHRONIC NON-SPECIFIC VULVOVAGINITIS IN IMMUNOCOMPROMISED GIRLS].

    Science.gov (United States)

    Nesterova, I; Kovaleva, S; Chudilova, G; Lomtatidze, L; Krutova, V; Aslanian, I; Tulendinova, A; Malinovskaya, V

    2017-05-01

    Nonspecific chronic vulvovaginitis (CNV) is often a clinical indicator of immune deficiency, especially in young girls. The established violations of the functioning of various parts of the immune system (IS) in this pathology dictate the need to include in the complex of immunomodulatory therapy. The developed program of combined immunotherapy for immunocompromised girls allows to reduce the severity and duration of exacerbation of CNV, their frequency against the background of a significant reduction in the incidence of ARVI. Positive clinical effects were observed against the background of the restoration of the functioning of the IS. A protective effect was obtained (observation in a catamnesis for 1 year) - the duration of a clinically safe period increased from 6 to 11-11,5 months per year.

  20. A multi-center study on low-frequency rTMS combined with intensive occupational therapy for upper limb hemiparesis in post-stroke patients

    Directory of Open Access Journals (Sweden)

    Kakuda Wataru

    2012-01-01

    Full Text Available Abstract Background Both low-frequency repetitive transcranial magnetic stimulation (rTMS and intensive occupational therapy (OT have been recently reported to be clinically beneficial for post-stroke patients with upper limb hemiparesis. Based on these reports, we developed an inpatient combination protocol of these two modalities for the treatment of such patients. The aims of this pilot study were to confirm the safety and feasibility of the protocol in a large number of patients from different institutions, and identify predictors of the clinical response to the treatment. Methods The study subjects were 204 post-stroke patients with upper limb hemiparesis (mean age at admission 58.5 ± 13.4 years, mean time after stroke 5.0 ± 4.5 years, ± SD from five institutions in Japan. During 15-day hospitalization, each patient received 22 treatment sessions of 20-min low-frequency rTMS and 120-min intensive OT daily. Low-frequency rTMS of 1 Hz was applied to the contralesional hemisphere over the primary motor area. The intensive OT, consisting of 60-min one-to-one training and 60-min self-exercise, was provided after the application of low-frequency rTMS. Fugl-Meyer Assessment (FMA and Wolf Motor Function Test (WMFT were performed serially. The physiatrists and occupational therapists involved in this study received training prior to the study to standardize the therapeutic protocol. Results All patients completed the protocol without any adverse effects. The FMA score increased and WMFT log performance time decreased significantly at discharge, relative to the respective values at admission (change in FMA score: median at admission, 47 points; median at discharge, 51 points; p Conclusions The 15-day inpatient rTMS plus OT protocol is a safe, feasible, and clinically useful neurorehabilitative intervention for post-stroke patients with upper limb hemiparesis. The response to the treatment was not influenced by age or time after stroke onset. The

  1. Low-frequency fluid waves in fractures and pipes

    Energy Technology Data Exchange (ETDEWEB)

    Korneev, Valeri

    2010-09-01

    Low-frequency analytical solutions have been obtained for phase velocities of symmetrical fluid waves within both an infinite fracture and a pipe filled with a viscous fluid. Three different fluid wave regimes can exist in such objects, depending on the various combinations of parameters, such as fluid density, fluid viscosity, walls shear modulus, channel thickness, and frequency. Equations for velocities of all these regimes have explicit forms and are verified by comparisons with the exact solutions. The dominant role of fractures in rock permeability at field scales and the strong amplitude and frequency effects of Stoneley guided waves suggest the importance of including these wave effects into poroelastic theories.

  2. Statistical frequency in perception affects children's lexical production.

    Science.gov (United States)

    Richtsmeier, Peter T; Gerken, LouAnn; Goffman, Lisa; Hogan, Tiffany

    2009-06-01

    Children's early word production is influenced by the statistical frequency of speech sounds and combinations. Three experiments asked whether this production effect can be explained by a perceptual learning mechanism that is sensitive to word-token frequency and/or variability. Four-year-olds were exposed to nonwords that were either frequent (presented 10 times) or infrequent (presented once). When the frequent nonwords were spoken by the same talker, children showed no significant effect of perceptual frequency on production. When the frequent nonwords were spoken by different talkers, children produced them with fewer errors and shorter latencies. The results implicate token variability in perceptual learning.

  3. Coherent laser radar with dual-frequency Doppler estimation and interferometric range detection

    NARCIS (Netherlands)

    Onori, D.; Scotti, F.; Laghezza, F.; Scaffardi, M.; Bogoni, A.

    2016-01-01

    The concept of a coherent interferometric dual frequency laser radar, that measures both the target range and velocity, is presented and experimentally demonstrated. The innovative architecture combines the dual frequency lidar concept, allowing a precise and robust Doppler estimation, with the

  4. Frequency multiplexing for readout of spin qubits

    Energy Technology Data Exchange (ETDEWEB)

    Hornibrook, J. M.; Colless, J. I.; Mahoney, A. C.; Croot, X. G.; Blanvillain, S.; Reilly, D. J., E-mail: david.reilly@sydney.edu.au [ARC Centre of Excellence for Engineered Quantum Systems, School of Physics, University of Sydney, Sydney, NSW 2006 (Australia); Lu, H.; Gossard, A. C. [Materials Department, University of California, Santa Barbara, California 93106 (United States)

    2014-03-10

    We demonstrate a low loss, chip-level frequency multiplexing scheme for readout of scaled-up spin qubit devices. By integrating separate bias tees and resonator circuits on-chip for each readout channel, we realise dispersive gate-sensing in combination with charge detection based on two radio frequency quantum point contacts. We apply this approach to perform multiplexed readout of a double quantum dot in the few-electron regime and further demonstrate operation of a 10-channel multiplexing device. Limitations for scaling spin qubit readout to large numbers of multiplexed channels are discussed.

  5. Compact blue laser devices based on nonlinear frequency upconversion

    International Nuclear Information System (INIS)

    Risk, W.P.

    1989-01-01

    This paper reports how miniature sources of coherent blue radiation can be produced by using nonlinear optical materials for frequency upconversion of the infrared radiation emitted by laser diodes. Direct upconversion of laser diode radiation is possible, but there are several advantages to using the diode laser to pump a solid-state laser which is then upconverted. In either case, the challenge is to find combinations of nonlinear materials and laser for efficient frequency upconversion. Several examples have been demonstrated. These include intracavity frequency doubling of a diode-pumped 946-nm Nd:YAG laser, intracavity frequency mixing of a 809-nm GaAlAs laser diode with a diode- pumped 1064-nm Nd:YAG laser, and direct frequency doubling of a 994-nm strained-layer InGaAs laser diode

  6. Switched capacitor DC-DC converter with switch conductance modulation and Pesudo-fixed frequency control

    DEFF Research Database (Denmark)

    Larsen, Dennis Øland; Vinter, Martin; Jørgensen, Ivan Harald Holger

    A switched capacitor dc-dc converter with frequency-planned control is presented. By splitting the output stage switches in eight segments the output voltage can be regulated with a combination of switching frequency and switch conductance. This allows for switching at predetermined frequencies, 31...

  7. Precipitation Estimation Using Combined Radar/Radiometer Measurements Within the GPM Framework

    Science.gov (United States)

    Hou, Arthur

    2012-01-01

    The Global Precipitation Measurement (GPM) Mission is an international satellite mission specifically designed to unify and advance precipitation measurements from a constellation of research and operational microwave sensors. The GPM mission centers upon the deployment of a Core Observatory in a 65o non-Sun-synchronous orbit to serve as a physics observatory and a transfer standard for intersatellite calibration of constellation radiometers. The GPM Core Observatory will carry a Ku/Ka-band Dual-frequency Precipitation Radar (DPR) and a conical-scanning multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The DPR will be the first dual-frequency radar in space to provide not only measurements of 3-D precipitation structures but also quantitative information on microphysical properties of precipitating particles needed for improving precipitation retrievals from microwave sensors. The DPR and GMI measurements will together provide a database that relates vertical hydrometeor profiles to multi-frequency microwave radiances over a variety of environmental conditions across the globe. This combined database will be used as a common transfer standard for improving the accuracy and consistency of precipitation retrievals from all constellation radiometers. For global coverage, GPM relies on existing satellite programs and new mission opportunities from a consortium of partners through bilateral agreements with either NASA or JAXA. Each constellation member may have its unique scientific or operational objectives but contributes microwave observations to GPM for the generation and dissemination of unified global precipitation data products. In addition to the DPR and GMI on the Core Observatory, the baseline GPM constellation consists of the following sensors: (1) Special Sensor Microwave Imager/Sounder (SSMIS) instruments on the U.S. Defense Meteorological Satellite Program (DMSP) satellites, (2) the Advanced Microwave Scanning Radiometer-2 (AMSR-2) on the GCOM-W1

  8. Embedding Number-Combinations Practice Within Word-Problem Tutoring

    Science.gov (United States)

    Powell, Sarah R.; Fuchs, Lynn S.; Fuchs, Douglas

    2012-01-01

    Two aspects of mathematics with which students with mathematics learning difficulty (MLD) often struggle are word problems and number-combination skills. This article describes a math program in which students receive instruction on using algebraic equations to represent the underlying problem structure for three word-problem types. Students also learn counting strategies for answering number combinations that they cannot retrieve from memory. Results from randomized-control trials indicated that embedding the counting strategies for number combinations produces superior word-problem and number-combination outcomes for students with MLD beyond tutoring programs that focus exclusively on number combinations or word problems. PMID:22661880

  9. Cost-effectiveness analysis of different types of human papillomavirus vaccination combined with a cervical cancer screening program in mainland China.

    Science.gov (United States)

    Mo, Xiuting; Gai Tobe, Ruoyan; Wang, Lijie; Liu, Xianchen; Wu, Bin; Luo, Huiwen; Nagata, Chie; Mori, Rintaro; Nakayama, Takeo

    2017-07-18

    China has a high prevalence of human papillomavirus (HPV) and a consequently high burden of disease with respect to cervical cancer. The HPV vaccine has proved to be effective in preventing cervical cancer and is now a part of routine immunization programs worldwide. It has also proved to be cost effective. This study aimed to assess the cost-effectiveness of 2-, 4-, and 9-valent HPV vaccines (hereafter, HPV2, 4 or 9) combined with current screening strategies in China. A Markov model was developed for a cohort of 100,000 HPV-free girls to simulate the natural history to HPV infection. Three recommended screening methods (1. liquid-based cytology test + HPV DNA test; 2. pap smear cytology test + HPV DNA test; 3. visual inspection with acetic acid) and three types of HPV vaccination program (HPV2/4/9) were incorporated into 15 intervention options, and the incremental cost-effectiveness ratio (ICER) was calculated to determine the dominant strategies. Costs, transition probabilities and utilities were obtained from a review of the literature and national databases. One-way sensitivity analyses and threshold analyses were performed for key variables in different vaccination scenarios. HPV9 combined with screening showed the highest health impact in terms of reducing HPV-related diseases and increasing the number of quality-adjusted life years (QALYs). Under the current thresholds of willingness to pay (WTP, 3 times the per capita GDP or USD$ 23,880), HPV4/9 proved highly cost effective, while HPV2 combined with screening cost more and was less cost effective. Only when screening coverage increased to 60% ~ 70% did the HPV2 and screening combination strategy become economically feasible. The combination of the HPV4/9 vaccine with current screening strategies for adolescent girls was highly cost-effective and had a significant impact on reducing the HPV infection-related disease burden in Mainland China.

  10. Frequency scaling of linear super-colliders

    International Nuclear Information System (INIS)

    Mondelli, A.; Chernin, D.; Drobot, A.; Reiser, M.; Granatstein, V.

    1986-06-01

    The development of electron-positron linear colliders in the TeV energy range will be facilitated by the development of high-power rf sources at frequencies above 2856 MHz. Present S-band technology, represented by the SLC, would require a length in excess of 50 km per linac to accelerate particles to energies above 1 TeV. By raising the rf driving frequency, the rf breakdown limit is increased, thereby allowing the length of the accelerators to be reduced. Currently available rf power sources set the realizable gradient limit in an rf linac at frequencies above S-band. This paper presents a model for the frequency scaling of linear colliders, with luminosity scaled in proportion to the square of the center-of-mass energy. Since wakefield effects are the dominant deleterious effect, a separate single-bunch simulation model is described which calculates the evolution of the beam bunch with specified wakefields, including the effects of using programmed phase positioning and Landau damping. The results presented here have been obtained for a SLAC structure, scaled in proportion to wavelength

  11. [Clinical effect of high-frequency oscillatory ventilation combined with pulmonary surfactant in treatment of neonatal severe meconium aspiration syndrome complicated by pulmonary hemorrhage].

    Science.gov (United States)

    Huang, Jing; Lin, Xin-Zhu; Zheng, Zhi

    2016-11-01

    To study the clinical effect and safety of high-frequency oscillatory ventilation (HFOV) combined with pulmonary surfactant (PS) in the treatment of neonatal severe meconium aspiration syndrome (MAS) complicated by neonatal pulmonary hemorrhage (NPH). A total of 48 children with severe MAS complicated by NPH were enrolled, and a retrospective analysis was performed for the clinical effects of HFOV+PS (trial group, 25 children) and HFOV alone (control group, 23 children). The blood gas parameters, oxygenation index (OI), PaO 2 /FiO 2 (P/F) value, duration of pulmonary hemorrhage, ventilation time, length of hospital stay, incidence of complications, and outcome were compared between the two groups. At 6, 12, 24, and 48 hours after treatment, the trial group had significantly better PaO 2 , OI, and P/F value than the control group (Phemorrhage (P0.05). HFOV combined with PS can better improve oxygenation function and shorten the duration of NPH and ventilation time. Meanwhile, it does not increase the incidence of adverse events. Therefore, it is a safe and effective therapy.

  12. Low-Frequency Ultrasound Therapy in Combination Treatment of Patients with Type 2 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    YE.E. LAVRINENKO

    2013-04-01

    Results. The beginning of therapeutic effect was observed after 2 procedures of the ultrasound exposure. The maximum effect is appeared after 8–10 treatment sessions. The positive dynamics of complex treatment is improving the general state of health, a disappearance of asthenization, and a decrease in the symptoms of cardiovascular disorders, achieving faster compensation of carbohydrate metabolism. The course of treatment contributed to the hyperglycemia reduction in patients with newly detected type 2 DM. After ultrasound treatment, the authors noted a positive dynamics of clinical symptoms: an improvement of the general health status, a decrease in fatigue, an improvement of psycho-emotional indices, disappearance of pain in the right upper quadrant, and a decrease in liver size in all the patients under study. Conclusions. The use of low-frequency ultrasound therapy on cutaneous projection of the liver in patients with type 2 DM promotes the normalization both fasting and postprandial glycemia. The effect of low-frequency ultrasound on cutaneous projection of the liver is significantly decreasing parameters that characterize the pancreatic insulin synthesizing function (immunoreactive insulin, C-peptide in patients with newly diagnosed type 2 DM and a BMI > 25 kg/m2. Low-frequency ultrasound reduces the glucagon secretion and thereby positively affects the hepatic gluconeogenesis. Ultrasound therapy can be used in the complex treatment of patients with newly diagnosed type 2 DM.

  13. A Dynamic Behaviour Analysis on the Frequency Control Capability of Electric Vehicles

    DEFF Research Database (Denmark)

    Zarogiannis, Athanasios; Marinelli, Mattia; Træholt, Chresten

    2014-01-01

    The paper presents results of a study on the dynamic response of Electric Vehicle’s (EV) when participating in frequency control of an islanded system. The following cases were considered: when there is no EV performing frequency control, when the EV participates in primary frequency control...... and when the EV participates in both primary and secondary frequency control. Different parameters are tested in various combinations, and their influence on frequency deviation as well as power and energy provided by the EV with vehicle-to-grid (V2G) capability is shown....

  14. Mono- and combination drug therapies in hospitalized patients with bipolar depression. Data from the European drug surveillance program AMSP

    Directory of Open Access Journals (Sweden)

    Haeberle Anne

    2012-09-01

    Full Text Available Abstract Background For the pharmacological treatment of bipolar depression several guidelines exist. It is largely unknown, to what extent the prescriptions in daily clinical routine correspond to these evidence based recommendations and which combinations of psychotropic drugs are frequently used. Methods The prescriptions of psychotropic drugs were investigated of all in-patients with bipolar depression (n = 2246; time period 1994–2009 from hospitals participating in the drug surveillance program AMSP. For the drug use in 2010, 221 cases were analysed additionally. Results From 1994 to 2009, 85% of all patients received more than one class of psychotropic substances: 74% received antidepressants in combination therapy, 55% antipsychotics, 48% anticonvulsants and 33% lithium. When given in combination, lithium is the most often prescribed substance for bipolar depression (33%, followed by valproic acid (23%, mirtazapine and venlafaxine (16% each, quetiapine (15%, lamotrigine (14% and olanzapine (13%. Both, lithium and valproic acid are often combined with selective serotonin reuptake inhibitors (SSRI, but also with mirtazapine und venlafaxine. Combinations of more than one antidepressant occur quite often, whereby combinations with bupropion, paroxetine, fluoxetine or fluvoxamine are very rare. In 2010, quetiapine (alone and combined was the most frequently prescribed drug (39%; aripiprazole was administered in 10%. Conclusion Combinations of antidepressants (SSRI, mirtazapine, venlafaxine with mood stabilizers (lithium, valproic acid, lamotrigine and / or atypical antipsychotics (quetiapine, olanzapine are common. Of most of those combinations the efficacy has not been studied. The use of aripiprazole and the concomitant use of two or three antidepressants contrast the guidelines.

  15. Microresonator-Based Optical Frequency Combs: A Time Domain Perspective

    Science.gov (United States)

    2016-04-19

    AFRL-AFOSR-VA-TR-2016-0165 (BRI) Microresonator-Based Optical Frequency Combs: A Time Domain Perspective Andrew Weiner PURDUE UNIVERSITY 401 SOUTH...Optical Frequency Combs: A Time Domain Perspective 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-12-1-0236 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data

  16. High-frequency energy in singing and speech

    Science.gov (United States)

    Monson, Brian Bruce

    While human speech and the human voice generate acoustical energy up to (and beyond) 20 kHz, the energy above approximately 5 kHz has been largely neglected. Evidence is accruing that this high-frequency energy contains perceptual information relevant to speech and voice, including percepts of quality, localization, and intelligibility. The present research was an initial step in the long-range goal of characterizing high-frequency energy in singing voice and speech, with particular regard for its perceptual role and its potential for modification during voice and speech production. In this study, a database of high-fidelity recordings of talkers was created and used for a broad acoustical analysis and general characterization of high-frequency energy, as well as specific characterization of phoneme category, voice and speech intensity level, and mode of production (speech versus singing) by high-frequency energy content. Directionality of radiation of high-frequency energy from the mouth was also examined. The recordings were used for perceptual experiments wherein listeners were asked to discriminate between speech and voice samples that differed only in high-frequency energy content. Listeners were also subjected to gender discrimination tasks, mode-of-production discrimination tasks, and transcription tasks with samples of speech and singing that contained only high-frequency content. The combination of these experiments has revealed that (1) human listeners are able to detect very subtle level changes in high-frequency energy, and (2) human listeners are able to extract significant perceptual information from high-frequency energy.

  17. Computation of High-Frequency Waves with Random Uncertainty

    KAUST Repository

    Malenova, Gabriela; Motamed, Mohammad; Runborg, Olof; Tempone, Raul

    2016-01-01

    or nonlinear functionals of the wave solution and its spatial/temporal derivatives. The numerical scheme combines two techniques: a high-frequency method based on Gaussian beams [2, 3], a sparse stochastic collocation method [4]. The fast spectral

  18. Sexual Behavior Among Young Carers in the Context of a Kenyan Empowerment Program Combining Cash-Transfer, Psychosocial Support, and Entrepreneurship.

    Science.gov (United States)

    Goodman, Michael L; Selwyn, Beatrice J; Morgan, Robert O; Lloyd, Linda E; Mwongera, Moses; Gitari, Stanley; Keiser, Philip H

    2016-01-01

    This study examined associations between sexual initiation, unprotected sex, and having multiple sex partners in the past year with participation in a three-year empowerment program targeting orphan and vulnerable children (OVC). The Kenya-based program combines community-conditioned cash transfer, psychosocial empowerment, health education, and microenterprise development. Program participants (n = 1,060) were interviewed in a cross-sectional design. Analyses used gender-stratified hierarchical logit models to assess program participation and other potential predictors. Significant predictors of increased female sexual activity included less program exposure, higher age, younger age at most recent parental death, fewer years of schooling, higher food consumption, higher psychological resilience, and lower general self-efficacy. Significant predictors of increased male sexual activity included more program exposure, higher age, better food consumption, not having a living father, and literacy. Findings support a nuanced view of current cash transfer programs, where female sexual activity may be reduced through improved financial status but male sexual activity may increase. Targeting of OVC sexual risk behaviors would likely benefit from being tailored according to associations found in this study. Data suggest involving fathers in sexual education, targeting women who lost a parent at a younger age, and providing social support for female OVC may decrease risk of human immunodeficiency virus (HIV) transmission.

  19. 34 CFR 686.33 - Frequency of payment.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Frequency of payment. 686.33 Section 686.33 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF POSTSECONDARY EDUCATION, DEPARTMENT OF EDUCATION TEACHER EDUCATION ASSISTANCE FOR COLLEGE AND HIGHER EDUCATION (TEACH) GRANT PROGRAM...

  20. 38 CFR 21.4233 - Combination.

    Science.gov (United States)

    2010-07-01

    ...) VOCATIONAL REHABILITATION AND EDUCATION Administration of Educational Assistance Programs Programs of... combination of institutional agricultural courses and concurrent agricultural employment (see § 21.4264). A... of the training bears to full time as defined in § 21.4270(c) of this part. The institutional portion...

  1. Precision Spectroscopy, Diode Lasers, and Optical Frequency Measurement Technology

    Science.gov (United States)

    Hollberg, Leo (Editor); Fox, Richard (Editor); Waltman, Steve (Editor); Robinson, Hugh

    1998-01-01

    This compilation is a selected set of reprints from the Optical Frequency Measurement Group of the Time and Frequency Division of the National Institute of Standards and Technology, and consists of work published between 1987 and 1997. The two main programs represented here are (1) development of tunable diode-laser technology for scientific applications and precision measurements, and (2) research toward the goal of realizing optical-frequency measurements and synthesis. The papers are organized chronologically in five, somewhat arbitrarily chosen categories: Diode Laser Technology, Tunable Laser Systems, Laser Spectroscopy, Optical Synthesis and Extended Wavelength Coverage, and Multi-Photon Interactions and Optical Coherences.

  2. Fruit and vegetable consumption and food values: National patterns in the United States by Supplemental Nutrition Assistance Program eligibility and cooking frequency.

    Science.gov (United States)

    Wolfson, Julia A; Bleich, Sara N

    2015-07-01

    More frequent cooking at home may help improve diet quality and be associated with food values, particularly for individuals participating in the Supplemental Nutrition Assistance Program (SNAP). To examine patterns of fruit and vegetable consumption and food values among adults (aged 20 and older) in the United States, by SNAP participation and household cooking frequency. Analysis of cross-sectional 24-hour dietary recall data obtained from the National Health and Nutrition Examination Survey 2007-2010 (N=9560). A lower percentage of SNAP participants consumed fruit (total: 35% vs. 46%, p=0.001; fresh: 30% vs. 41%, pcooking >6times/week was associated with greater vegetable consumption compared to cooking cooked ≥2times/week were more to report price (medium cookers: 47% vs. 33%, p=0.001; high cookers: 52% vs. 40%, pcooking frequency. Efforts to improve diet quality should consider values on which food purchases are based. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Radio Frequency Transistors Using Aligned Semiconducting Carbon Nanotubes with Current-Gain Cutoff Frequency and Maximum Oscillation Frequency Simultaneously Greater than 70 GHz.

    Science.gov (United States)

    Cao, Yu; Brady, Gerald J; Gui, Hui; Rutherglen, Chris; Arnold, Michael S; Zhou, Chongwu

    2016-07-26

    In this paper, we report record radio frequency (RF) performance of carbon nanotube transistors based on combined use of a self-aligned T-shape gate structure, and well-aligned, high-semiconducting-purity, high-density polyfluorene-sorted semiconducting carbon nanotubes, which were deposited using dose-controlled, floating evaporative self-assembly method. These transistors show outstanding direct current (DC) performance with on-current density of 350 μA/μm, transconductance as high as 310 μS/μm, and superior current saturation with normalized output resistance greater than 100 kΩ·μm. These transistors create a record as carbon nanotube RF transistors that demonstrate both the current-gain cutoff frequency (ft) and the maximum oscillation frequency (fmax) greater than 70 GHz. Furthermore, these transistors exhibit good linearity performance with 1 dB gain compression point (P1dB) of 14 dBm and input third-order intercept point (IIP3) of 22 dBm. Our study advances state-of-the-art of carbon nanotube RF electronics, which have the potential to be made flexible and may find broad applications for signal amplification, wireless communication, and wearable/flexible electronics.

  4. Photonic integrated single-sideband modulator / frequency shifter based on surface acoustic waves

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva; Hvam, Jørn Märcher

    2010-01-01

    Optical frequency shifters are essential components of many systems. In this paper, a compact integrated optical frequency shifter is designed making use of the combination of surface acoustic waves and Mach-Zehnder interferometers. It has a very simple operation setup and can be fabricated...

  5. Power system frequency estimation based on an orthogonal decomposition method

    Science.gov (United States)

    Lee, Chih-Hung; Tsai, Men-Shen

    2018-06-01

    In recent years, several frequency estimation techniques have been proposed by which to estimate the frequency variations in power systems. In order to properly identify power quality issues under asynchronously-sampled signals that are contaminated with noise, flicker, and harmonic and inter-harmonic components, a good frequency estimator that is able to estimate the frequency as well as the rate of frequency changes precisely is needed. However, accurately estimating the fundamental frequency becomes a very difficult task without a priori information about the sampling frequency. In this paper, a better frequency evaluation scheme for power systems is proposed. This method employs a reconstruction technique in combination with orthogonal filters, which may maintain the required frequency characteristics of the orthogonal filters and improve the overall efficiency of power system monitoring through two-stage sliding discrete Fourier transforms. The results showed that this method can accurately estimate the power system frequency under different conditions, including asynchronously sampled signals contaminated by noise, flicker, and harmonic and inter-harmonic components. The proposed approach also provides high computational efficiency.

  6. An ultra-stable iodine-based frequency reference for space applications

    Science.gov (United States)

    Schuldt, Thilo; Braxmaier, Claus; Doeringshoff, Klaus; Keetman, Anja; Reggentin, Matthias; Kovalchuk, Evgeny; Peters, Achim

    2012-07-01

    Future space missions require for ultra-stable optical frequency references. Examples are the gravitational wave detector LISA/eLISA (Laser Interferometer Space Antenna), the SpaceTime Asymmetry Research (STAR) program, the aperture-synthesis telescope Darwin and the GRACE (Gravity Recovery and Climate Experiment) follow on mission exploring Earth's gravity. As high long-term frequency stability is required, lasers stabilized to atomic or molecular transitions are preferred, also offering an absolute frequency reference. Frequency stabilities in the 10 ^{-15} domains at longer integration times (up to several hours) are demonstrated in laboratory experiments using setups based on Doppler-free spectroscopy. Such setups with a frequency stability comparable to the hydrogen maser in the microwave domain, have the potential to be developed space compatible on a relatively short time scale. Here, we present the development of ultra-stable optical frequency references based on modulation-transfer spectroscopy of molecular iodine. Noise levels of 2\\cdot10 ^{-14} at an integration time of 1 s and below 3\\cdot10 ^{-15} at integration times between 100 s and 1000 s are demonstrated with a laboratory setup using an 80 cm long iodine cell in single-pass configuration in combination with a frequency-doubled Nd:YAG laser and standard optical components and optomechanic mounts. The frequency stability at longer integration times is (amongst other things) limited by the dimensional stability of the optical setup, i.e. by th pointing stability of the two counter-propagating beams overlapped in the iodine cell. With the goal of a future space compatible setup, a compact frequency standard on EBB (elegant breadboard) level was realized. The spectroscopy unit utilizes a baseplate made of Clearceram-HS, a glass ceramics with an ultra-low coefficient of thermal expansion of 2\\cdot10 ^{-8} K ^{-1}. The optical components are joint to the baseplate using adhesive bonding technology

  7. Artificial excitation of ELF waves with frequency of Schumann resonance

    Science.gov (United States)

    Streltsov, A. V.; Guido, T.; Tulegenov, B.; Labenski, J.; Chang, C.-L.

    2014-11-01

    We report results from the experiment aimed at the artificial excitation of extremely low-frequency (ELF) electromagnetic waves with frequencies corresponding to the frequency of Schumann resonance. Electromagnetic waves with these frequencies can form a standing pattern inside the spherical cavity formed by the surface of the Earth and the ionosphere. In the experiment the ELF waves were excited by heating the ionosphere with X-mode HF electromagnetic waves generated at the High Frequency Active Auroral Research Program (HAARP) facility in Alaska. The experiment demonstrates that heating of the ionosphere can excite relatively large-amplitude electromagnetic waves with frequencies in the range 7.8-8.0 Hz when the ionosphere has a strong F layer, the frequency of the HF radiation is in the range 3.20-4.57 MHz, and the electric field greater than 5 mV/m is present in the ionosphere.

  8. Day-Ahead Scheduling Considering Demand Response as a Frequency Control Resource

    Directory of Open Access Journals (Sweden)

    Yu-Qing Bao

    2017-01-01

    Full Text Available The development of advanced metering technologies makes demand response (DR able to provide fast response services, e.g., primary frequency control. It is recognized that DR can contribute to the primary frequency control like thermal generators. This paper proposes a day-ahead scheduling method that considers DR as a frequency control resource, so that the DR resources can be dispatched properly with other resources. In the proposed method, the objective of frequency control is realized by defining a frequency limit equation under a supposed contingency. The frequency response model is used to model the dynamics of system frequency. The nonlinear frequency limit equation is transformed to a linear arithmetic equation by piecewise linearization, so that the problem can be solved by mixed integer linear programming (MILP. Finally, the proposed method is verified on numerical examples.

  9. Acoustic frequency filter based on anisotropic topological phononic crystals

    KAUST Repository

    Chen, Zeguo

    2017-11-02

    We present a design of acoustic frequency filter based on a two-dimensional anisotropic phononic crystal. The anisotropic band structure exhibits either a directional or a combined (global + directional) bandgap at certain frequency regions, depending on the geometry. When the time-reversal symmetry is broken, it may introduce a topologically nontrivial bandgap. The induced nontrivial bandgap and the original directional bandgap result in various interesting wave propagation behaviors, such as frequency filter. We develop a tight-binding model to characterize the effective Hamiltonian of the system, from which the contribution of anisotropy is explicitly shown. Different from the isotropic cases, the Zeeman-type splitting is not linear and the anisotropic bandgap makes it possible to achieve anisotropic propagation characteristics along different directions and at different frequencies.

  10. Rectennas at optical frequencies: How to analyze the response

    International Nuclear Information System (INIS)

    Joshi, Saumil; Moddel, Garret

    2015-01-01

    Optical rectennas, antenna-coupled diode rectifiers that receive optical-frequency electromagnetic radiation and convert it to DC output, have been proposed for use in harvesting electromagnetic radiation from a blackbody source. The operation of these devices is qualitatively different from that of lower-frequency rectennas, and their design requires a new approach. To that end, we present a method to determine the rectenna response to high frequency illumination. It combines classical circuit analysis with classical and quantum-based photon-assisted tunneling response of a high-speed diode. We demonstrate the method by calculating the rectenna response for low and high frequency monochromatic illumination, and for radiation from a blackbody source. Such a blackbody source can be a hot body generating waste heat, or radiation from the sun

  11. Rectennas at optical frequencies: How to analyze the response

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Saumil; Moddel, Garret, E-mail: moddel@colorado.edu [Department of Electrical, Computer, and Energy Engineering, University of Colorado, Boulder, Colorado 80309-0425 (United States)

    2015-08-28

    Optical rectennas, antenna-coupled diode rectifiers that receive optical-frequency electromagnetic radiation and convert it to DC output, have been proposed for use in harvesting electromagnetic radiation from a blackbody source. The operation of these devices is qualitatively different from that of lower-frequency rectennas, and their design requires a new approach. To that end, we present a method to determine the rectenna response to high frequency illumination. It combines classical circuit analysis with classical and quantum-based photon-assisted tunneling response of a high-speed diode. We demonstrate the method by calculating the rectenna response for low and high frequency monochromatic illumination, and for radiation from a blackbody source. Such a blackbody source can be a hot body generating waste heat, or radiation from the sun.

  12. Rectennas at optical frequencies: How to analyze the response

    Science.gov (United States)

    Joshi, Saumil; Moddel, Garret

    2015-08-01

    Optical rectennas, antenna-coupled diode rectifiers that receive optical-frequency electromagnetic radiation and convert it to DC output, have been proposed for use in harvesting electromagnetic radiation from a blackbody source. The operation of these devices is qualitatively different from that of lower-frequency rectennas, and their design requires a new approach. To that end, we present a method to determine the rectenna response to high frequency illumination. It combines classical circuit analysis with classical and quantum-based photon-assisted tunneling response of a high-speed diode. We demonstrate the method by calculating the rectenna response for low and high frequency monochromatic illumination, and for radiation from a blackbody source. Such a blackbody source can be a hot body generating waste heat, or radiation from the sun.

  13. Acoustic frequency filter based on anisotropic topological phononic crystals

    KAUST Repository

    Chen, Zeguo; Zhao, Jiajun; Mei, Jun; Wu, Ying

    2017-01-01

    We present a design of acoustic frequency filter based on a two-dimensional anisotropic phononic crystal. The anisotropic band structure exhibits either a directional or a combined (global + directional) bandgap at certain frequency regions, depending on the geometry. When the time-reversal symmetry is broken, it may introduce a topologically nontrivial bandgap. The induced nontrivial bandgap and the original directional bandgap result in various interesting wave propagation behaviors, such as frequency filter. We develop a tight-binding model to characterize the effective Hamiltonian of the system, from which the contribution of anisotropy is explicitly shown. Different from the isotropic cases, the Zeeman-type splitting is not linear and the anisotropic bandgap makes it possible to achieve anisotropic propagation characteristics along different directions and at different frequencies.

  14. Object-oriented Programming Laws for Annotated Java Programs

    Directory of Open Access Journals (Sweden)

    Gabriel Falconieri Freitas

    2010-03-01

    Full Text Available Object-oriented programming laws have been proposed in the context of languages that are not combined with a behavioral interface specification language (BISL. The strong dependence between source-code and interface specifications may cause a number of difficulties when transforming programs. In this paper we introduce a set of programming laws for object-oriented languages like Java combined with the Java Modeling Language (JML. The set of laws deals with object-oriented features taking into account their specifications. Some laws deal only with features of the specification language. These laws constitute a set of small transformations for the development of more elaborate ones like refactorings.

  15. Thermal history of the plasma and high-frequency gravitons

    CERN Document Server

    Giovannini, Massimo

    2009-01-01

    Possible deviations from a radiation-dominated evolution, occurring prior the synthesis of light nuclei, impacted on the spectral energy density of high-frequency gravitons. For a systematic scrutiny of this situation, the $\\Lambda$CDM paradigm must be complemented by (at least two) physical parameters describing, respectively, a threshold frequency and a slope. The supplementary frequency scale sets the lower border of a high-frequency domain where the spectral energy grows with a slope which depends, predominantly, upon the total sound speed of the plasma right after inflation. While the infra-red region of the graviton energy spectrum is nearly scale-invariant, the expected signals for typical frequencies larger than 0.01 nHz are hereby analyzed in a model-independent framework by requiring that the total sound speed of the post-inflationary plasma is smaller than the speed of light. Current (e.g. low-frequency) upper limits on the tensor power spectra (determined from the combined analysis of the three la...

  16. Non-linear frequency and amplitude modulation of a nano-contact spin torque oscillator

    OpenAIRE

    Muduli, P. K.; Pogoryelov, Ye.; Bonetti, S.; Consolo, G.; Mancoff, Fred; Åkerman, Johan

    2009-01-01

    We study the current controlled modulation of a nano-contact spin torque oscillator. Three principally different cases of frequency non-linearity ($d^{2}f/dI^{2}_{dc}$ being zero, positive, and negative) are investigated. Standard non-linear frequency modulation theory is able to accurately describe the frequency shifts during modulation. However, the power of the modulated sidebands only agrees with calculations based on a recent theory of combined non-linear frequency and amplitude modulation.

  17. Adding part-of-speech information to the SUBTLEX-US word frequencies.

    Science.gov (United States)

    Brysbaert, Marc; New, Boris; Keuleers, Emmanuel

    2012-12-01

    The SUBTLEX-US corpus has been parsed with the CLAWS tagger, so that researchers have information about the possible word classes (parts-of-speech, or PoSs) of the entries. Five new columns have been added to the SUBTLEX-US word frequency list: the dominant (most frequent) PoS for the entry, the frequency of the dominant PoS, the frequency of the dominant PoS relative to the entry's total frequency, all PoSs observed for the entry, and the respective frequencies of these PoSs. Because the current definition of lemma frequency does not seem to provide word recognition researchers with useful information (as illustrated by a comparison of the lemma frequencies and the word form frequencies from the Corpus of Contemporary American English), we have not provided a column with this variable. Instead, we hope that the full list of PoS frequencies will help researchers to collectively determine which combination of frequencies is the most informative.

  18. Effect of section shape on frequencies of natural oscillations of tubular springs

    Science.gov (United States)

    Pirogov, S. P.; Chuba, A. Yu; Cherentsov, D. A.

    2018-05-01

    The necessity of determining the frequencies of natural oscillations of manometric tubular springs is substantiated. Based on the mathematical model and computer program, numerical experiments were performed that allowed us to reveal the effect of geometric parameters on the frequencies of free oscillations of manometric tubular springs.

  19. Rocket-Based Combined Cycle Activities in the Advanced Space Transportation Program Office

    Science.gov (United States)

    Hueter, Uwe; Turner, James

    1999-01-01

    NASA's Office of Aero-Space Technology (OAST) has established three major goals, referred to as, "The Three Pillars for Success". The Advanced Space Transportation Program Office (ASTP) at the NASA's Marshall Space Flight Center (MSFC) in Huntsville, Ala. focuses on future space transportation technologies Under the "Access to Space" pillar. The Core Technologies Project, part of ASTP, focuses on the reusable technologies beyond those being pursued by X-33. One of the main activities over the past two and a half years has been on advancing the rocket-based combined cycle (RBCC) technologies. In June of last year, activities for reusable launch vehicle (RLV) airframe and propulsion technologies were initiated. These activities focus primarily on those technologies that support the decision to determine the path this country will take for Space Shuttle and RLV. This year, additional technology efforts in the reusable technologies will be awarded. The RBCC effort that was completed early this year was the initial step leading to flight demonstrations of the technology for space launch vehicle propulsion.

  20. A generalized strategy for designing (19)F/(1)H dual-frequency MRI coil for small animal imaging at 4.7 Tesla.

    Science.gov (United States)

    Hu, Lingzhi; Hockett, Frank D; Chen, Junjie; Zhang, Lei; Caruthers, Shelton D; Lanza, Gregory M; Wickline, Samuel A

    2011-07-01

    To propose and test a universal strategy for building (19) F/(1) H dual-frequency RF coil that permits multiple coil geometries. The feasibility to design (19) F/(1) H dual-frequency RF coil based on coupled resonator model was investigated. A series capacitive matching network enables robust impedance matching for both harmonic oscillating modes of the coupled resonator. Two typical designs of (19) F/(1) H volume coils (birdcage and saddle) at 4.7T were implemented and evaluated with electrical bench test and in vivo (19) F/(1) H dual-nuclei imaging. For various combinations of internal resistances of the sample coil and secondary resonator, numerical solutions for the tunable capacitors to optimize impedance matching were obtained using a root-seeking program. Identical and homogeneous B1 field distribution at (19) F and (1) H frequencies were observed in bench test and phantom image. Finally, in vivo mouse imaging confirmed the sensitivity and homogeneity of the (19) F/(1) H dual-frequency coil design. A generalized strategy for designing (19) F/(1) H dual-frequency coils based on the coupled resonator approach was developed and validated. A unique feature of this design is that it preserves the B1 field homogeneity of the RF coil at both resonant frequencies. Thus it minimizes the susceptibility effect on image co-registration. Copyright © 2011 Wiley-Liss, Inc.

  1. Advanced validation of CFD-FDTD combined method using highly applicable solver for reentry blackout prediction

    International Nuclear Information System (INIS)

    Takahashi, Yusuke

    2016-01-01

    An analysis model of plasma flow and electromagnetic waves around a reentry vehicle for radio frequency blackout prediction during aerodynamic heating was developed in this study. The model was validated based on experimental results from the radio attenuation measurement program. The plasma flow properties, such as electron number density, in the shock layer and wake region were obtained using a newly developed unstructured grid solver that incorporated real gas effect models and could treat thermochemically non-equilibrium flow. To predict the electromagnetic waves in plasma, a frequency-dependent finite-difference time-domain method was used. Moreover, the complicated behaviour of electromagnetic waves in the plasma layer during atmospheric reentry was clarified at several altitudes. The prediction performance of the combined model was evaluated with profiles and peak values of the electron number density in the plasma layer. In addition, to validate the models, the signal losses measured during communication with the reentry vehicle were directly compared with the predicted results. Based on the study, it was suggested that the present analysis model accurately predicts the radio frequency blackout and plasma attenuation of electromagnetic waves in plasma in communication. (paper)

  2. Three-dimensional sensing methodology combining stereo vision and phase-measuring profilometry based on dynamic programming

    Science.gov (United States)

    Lee, Hyunki; Kim, Min Young; Moon, Jeon Il

    2017-12-01

    Phase measuring profilometry and moiré methodology have been widely applied to the three-dimensional shape measurement of target objects, because of their high measuring speed and accuracy. However, these methods suffer from inherent limitations called a correspondence problem, or 2π-ambiguity problem. Although a kind of sensing method to combine well-known stereo vision and phase measuring profilometry (PMP) technique simultaneously has been developed to overcome this problem, it still requires definite improvement for sensing speed and measurement accuracy. We propose a dynamic programming-based stereo PMP method to acquire more reliable depth information and in a relatively small time period. The proposed method efficiently fuses information from two stereo sensors in terms of phase and intensity simultaneously based on a newly defined cost function of dynamic programming. In addition, the important parameters are analyzed at the view point of the 2π-ambiguity problem and measurement accuracy. To analyze the influence of important hardware and software parameters related to the measurement performance and to verify its efficiency, accuracy, and sensing speed, a series of experimental tests were performed with various objects and sensor configurations.

  3. Reactive Programming in Java

    CERN Document Server

    CERN. Geneva

    2017-01-01

    Reactive Programming in gaining a lot of excitement. Many libraries, tools, and frameworks are beginning to make use of reactive libraries. Besides, applications dealing with big data or high frequency data can benefit from this programming paradigm. Come to this presentation to learn about what reactive programming is, what kind of problems it solves, how it solves them. We will take an example oriented approach to learning the programming model and the abstraction.

  4. Frequency Based Real-time Pricing for Residential Prosumers

    Science.gov (United States)

    Hambridge, Sarah Mabel

    stability in a free, competitive, market. Frequency based pricing is applied to secondary frequency control in this work, providing support at one to five minute time intervals. In Chapter 2, a frequency based pricing curve is designed as a preliminary study and the response of the prosumer is optimized for economic dispatch. In Chapter 3, a day-ahead schedule and real-time adjustment energy management framework is presented for the prosumer, creating a market structure similar to the existing energy market supervised by Independent System Operators (ISOs). Enabling technology, such as the solid state transformer (SST) is described for prosumer energy transactions, controlling power flow from the prosumer's energy cell to the grid or neighboring prosumer as an energy router. Experimental results are shown to demonstrate this capability. Additionally, the SST is capable of measuring the grid frequency. Lastly, a frequency based real-time hybrid electricity rate is presented in Chapter 4 and Chapter 5. Chapter 4 specializes in a single direction rate while Chapter 5 presents a bi-directional rate. A Time-of-use (TOU) rate is combined with the real-time frequency based price to lower energy bills for a residential prosumer with ESS, in agreement with the proposed day-ahead and real-time energy management framework. The cost to the ESS is also considered in this section. Linear programming and strategic rule based methods are utilized to find the lowest energy bill. As a result, prosumers can use ESS to balance the grid, reducing their bill as much per kWh as PV or DG under a TOU net-metering price scheme, while providing distributed frequency support to the grid authority. The variability of the frequency based rate is similar to variability in the stock market, which gives a sense of how prosumers will interact with variable prices in a system supported by The Energy Internet.

  5. Comparing models of the combined-stimulation advantage for speech recognition.

    Science.gov (United States)

    Micheyl, Christophe; Oxenham, Andrew J

    2012-05-01

    The "combined-stimulation advantage" refers to an improvement in speech recognition when cochlear-implant or vocoded stimulation is supplemented by low-frequency acoustic information. Previous studies have been interpreted as evidence for "super-additive" or "synergistic" effects in the combination of low-frequency and electric or vocoded speech information by human listeners. However, this conclusion was based on predictions of performance obtained using a suboptimal high-threshold model of information combination. The present study shows that a different model, based on Gaussian signal detection theory, can predict surprisingly large combined-stimulation advantages, even when performance with either information source alone is close to chance, without involving any synergistic interaction. A reanalysis of published data using this model reveals that previous results, which have been interpreted as evidence for super-additive effects in perception of combined speech stimuli, are actually consistent with a more parsimonious explanation, according to which the combined-stimulation advantage reflects an optimal combination of two independent sources of information. The present results do not rule out the possible existence of synergistic effects in combined stimulation; however, they emphasize the possibility that the combined-stimulation advantages observed in some studies can be explained simply by non-interactive combination of two information sources.

  6. Efficient coding schemes with power allocation using space-time-frequency spreading

    Institute of Scientific and Technical Information of China (English)

    Jiang Haining; Luo Hanwen; Tian Jifeng; Song Wentao; Liu Xingzhao

    2006-01-01

    An efficient space-time-frequency (STF) coding strategy for multi-input multi-output orthogonal frequency division multiplexing (MIMO-OFDM) systems is presented for high bit rate data transmission over frequency selective fading channels. The proposed scheme is a new approach to space-time-frequency coded OFDM (COFDM) that combines OFDM with space-time coding, linear precoding and adaptive power allocation to provide higher quality of transmission in terms of the bit error rate performance and power efficiency. In addition to exploiting the maximum diversity gain in frequency, time and space, the proposed scheme enjoys high coding advantages and low-complexity decoding. The significant performance improvement of our design is confirmed by corroborating numerical simulations.

  7. Controller design for flexible, distributed parameter mechanical arms via combined state space and frequency domain techniques

    Science.gov (United States)

    Book, W. J.; Majett, M.

    1982-01-01

    The potential benefits of the ability to control more flexible mechanical arms are discussed. A justification is made in terms of speed of movement. A new controller design procedure is then developed to provide this capability. It uses both a frequency domain representation and a state variable representation of the arm model. The frequency domain model is used to update the modal state variable model to insure decoupled states. The technique is applied to a simple example with encouraging results.

  8. Carbon nanotube transistor based high-frequency electronics

    Science.gov (United States)

    Schroter, Michael

    At the nanoscale carbon nanotubes (CNTs) have higher carrier mobility and carrier velocity than most incumbent semiconductors. Thus CNT based field-effect transistors (FETs) are being considered as strong candidates for replacing existing MOSFETs in digital applications. In addition, the predicted high intrinsic transit frequency and the more recent finding of ways to achieve highly linear transfer characteristics have inspired investigations on analog high-frequency (HF) applications. High linearity is extremely valuable for an energy efficient usage of the frequency spectrum, particularly in mobile communications. Compared to digital applications, the much more relaxed constraints for CNT placement and lithography combined with already achieved operating frequencies of at least 10 GHz for fabricated devices make an early entry in the low GHz HF market more feasible than in large-scale digital circuits. Such a market entry would be extremely beneficial for funding the development of production CNTFET based process technology. This talk will provide an overview on the present status and feasibility of HF CNTFET technology will be given from an engineering point of view, including device modeling, experimental results, and existing roadblocks. Carbon nanotube transistor based high-frequency electronics.

  9. Harmonic Frequency Lowering: Effects on the Perception of Music Detail and Sound Quality.

    Science.gov (United States)

    Kirchberger, Martin; Russo, Frank A

    2016-02-01

    A novel algorithm for frequency lowering in music was developed and experimentally tested in hearing-impaired listeners. Harmonic frequency lowering (HFL) combines frequency transposition and frequency compression to preserve the harmonic content of music stimuli. Listeners were asked to make judgments regarding detail and sound quality in music stimuli. Stimuli were presented under different signal processing conditions: original, low-pass filtered, HFL, and nonlinear frequency compressed. Results showed that participants reported perceiving the most detail in the HFL condition. In addition, there was no difference in sound quality across conditions. © The Author(s) 2016.

  10. Pulse-coupled Belousov-Zhabotinsky oscillators with frequency modulation

    Science.gov (United States)

    Horvath, Viktor; Epstein, Irving R.

    2018-04-01

    Inhibitory perturbations to the ferroin-catalyzed Belousov-Zhabotinsky (BZ) chemical oscillator operated in a continuously fed stirred tank reactor cause long term changes to the limit cycle: the lengths of the cycles subsequent to the perturbation are longer than that of the unperturbed cycle, and the unperturbed limit cycle is recovered only after several cycles. The frequency of the BZ reaction strongly depends on the acid concentration of the medium. By adding strong acid or base to the perturbing solutions, the magnitude and the direction of the frequency changes concomitant to excitatory or inhibitory perturbations can be controlled independently of the coupling strength. The dynamics of two BZ oscillators coupled through perturbations carrying a coupling agent (activator or inhibitor) and a frequency modulator (strong acid or base) was explored using a numerical model of the system. Here, we report new complex temporal patterns: higher order, partially synchronized modes that develop when inhibitory coupling is combined with positive frequency modulation (FM), and complex bursting patterns when excitatory coupling is combined with negative FM. The role of time delay between the peak and perturbation (the analog of synaptic delays in networks of neurons) has also been studied. The complex patterns found under inhibitory coupling and positive FM vanish when the delay is significant, whereas a sufficiently long time delay is required for the complex temporal dynamics to occur when coupling is excitatory and FM is negative.

  11. Statistical Frequency in Perception Affects Children’s Lexical Production

    Science.gov (United States)

    Richtsmeier, Peter T.; Gerken, LouAnn; Goffman, Lisa; Hogan, Tiffany

    2009-01-01

    Children’s early word production is influenced by the statistical frequency of speech sounds and combinations. Three experiments asked whether this production effect can be explained by a perceptual learning mechanism that is sensitive to word-token frequency and/or variability. Four-year-olds were exposed to nonwords that were either frequent (presented 10 times) or infrequent (presented once). When the frequent nonwords were spoken by the same talker, children showed no significant effect of perceptual frequency on production. When the frequent nonwords were spoken by different talkers, children produced them with fewer errors and shorter latencies. The results implicate token variability in perceptual learning. PMID:19338981

  12. Resonant High Power Combiners

    CERN Document Server

    Langlois, Michel; Peillex-Delphe, Guy

    2005-01-01

    Particle accelerators need radio frequency sources. Above 300 MHz, the amplifiers mostly used high power klystrons developed for this sole purpose. As for military equipment, users are drawn to buy "off the shelf" components rather than dedicated devices. IOTs have replaced most klystrons in TV transmitters and find their way in particle accelerators. They are less bulky, easier to replace, more efficient at reduced power. They are also far less powerful. What is the benefit of very compact sources if huge 3 dB couplers are needed to combine the power? To alleviate this drawback, we investigated a resonant combiner, operating in TM010 mode, able to combine 3 to 5 IOTs. Our IOTs being able to deliver 80 kW C.W. apiece, combined power would reach 400 kW minus the minor insertion loss. Values for matching and insertion loss are given. The behavior of the system in case of IOT failure is analyzed.

  13. Enhancing the accuracy of GPS point positioning by converting the single frequency data to dual frequency data

    Directory of Open Access Journals (Sweden)

    Aly M. El-naggar

    2011-09-01

    Full Text Available The global positioning system (GPS has been used to support a wide variety of applications, such as high-accuracy positioning and navigation. Differential GPS techniques can largely eliminate common-mode errors between the reference and the rover GPS stations resulting from ionospheric and tropospheric refraction and delays, satellite and receiver clock biases, and orbital errors [1]. The ionospheric delay in the propagation of global positioning system (GPS signals is one of the main sources of error in GPS precise positioning and navigation. A dual-frequency GPS receiver can eliminate (to the first order the ionospheric delay through a linear combination of the L1 and L2 observations [2]. The most significant effect of ionospheric delay appear in case of using single frequency data. In this paper the single frequency data of concerned station are converted to dual frequency data by employing dual frequency data from 11 regional GPS stations distributed around it. Total electron content (TEC was calculated at every GPS station to produce the mathematical model of TEC which is a function of latitude (Φ and longitude (λ. By using this mathematical model the values of TEC and L2 can be predicted at the single frequency GPS station for each satellite, after that the comparison between predicted and observation values of TEC and L2 was performed. The estimation method and test results of the proposed method indicates that the difference between predicted and observation values is very small.

  14. Effectiveness of the Vital Aging program to promote active aging in Mexican older adults

    Science.gov (United States)

    Mendoza-Ruvalcaba, Neyda Ma; Fernández-Ballesteros, Rocío

    2016-01-01

    Introduction Aging is not only a population phenomenon but also an experience and an individual reality. Vital Aging® is a program that considers active aging as the lifelong adaptation process of maximizing health and independence, physical and cognitive functioning, positive affect regulation and control, and social engagement. Through its different versions and editions, it has demonstrated being an effective program to promote active aging. The aim of this study is to determine the effectiveness of the “face-to-face” and “combined” versions of the program to promote active aging in Mexican older adults trial. Methods Seventy-six older adults aged 60 years and over participated in a quasi-experimental study and were recruited in a senior center to participate in the two experimental conditions: Vital Aging face-to-face (VA-FF) (n=35) and Vital Aging combined (VA-C; multimedia/face-to-face) (n=15), and the remaining 26 adults were assigned to a control group. Pretest and posttest assessments were performed after the theoretical–practical intervention. Mean differences and size effects were calculated for estimating the effect of the program. Results At the end of the study, participants showed improvements in the active aging outcome measures. Positive effects were observed in the frequency of intellectual, cultural – artistic, and social activities, perceptions of aging, satisfaction with social relationships, and self-efficacy for aging. Additionally, those who participated in VA-FF showed better memory performance, meta-memory, and a trend to report less memory problems, while older persons in VA-C showed a trend to have better life satisfaction. No effects were observed in physical activity, frequency of social relationships, and subjective health. Conclusion Findings show that the Vital Aging program in face-to-face and combined versions encourages active aging in Mexican older persons. These results are in general similar to those found in

  15. A Joint Method of Envelope Inversion Combined with Hybrid-domain Full Waveform Inversion

    Science.gov (United States)

    CUI, C.; Hou, W.

    2017-12-01

    Full waveform inversion (FWI) aims to construct high-precision subsurface models by fully using the information in seismic records, including amplitude, travel time, phase and so on. However, high non-linearity and the absence of low frequency information in seismic data lead to the well-known cycle skipping problem and make inversion easily fall into local minima. In addition, those 3D inversion methods that are based on acoustic approximation ignore the elastic effects in real seismic field, and make inversion harder. As a result, the accuracy of final inversion results highly relies on the quality of initial model. In order to improve stability and quality of inversion results, multi-scale inversion that reconstructs subsurface model from low to high frequency are applied. But, the absence of very low frequencies (time domain and inversion in the frequency domain. To accelerate the inversion, we adopt CPU/GPU heterogeneous computing techniques. There were two levels of parallelism. In the first level, the inversion tasks are decomposed and assigned to each computation node by shot number. In the second level, GPU multithreaded programming is used for the computation tasks in each node, including forward modeling, envelope extraction, DFT (discrete Fourier transform) calculation and gradients calculation. Numerical tests demonstrated that the combined envelope inversion + hybrid-domain FWI could obtain much faithful and accurate result than conventional hybrid-domain FWI. The CPU/GPU heterogeneous parallel computation could improve the performance speed.

  16. Robust and efficient multi-frequency temporal phase unwrapping: optimal fringe frequency and pattern sequence selection.

    Science.gov (United States)

    Zhang, Minliang; Chen, Qian; Tao, Tianyang; Feng, Shijie; Hu, Yan; Li, Hui; Zuo, Chao

    2017-08-21

    Temporal phase unwrapping (TPU) is an essential algorithm in fringe projection profilometry (FPP), especially when measuring complex objects with discontinuities and isolated surfaces. Among others, the multi-frequency TPU has been proven to be the most reliable algorithm in the presence of noise. For a practical FPP system, in order to achieve an accurate, efficient, and reliable measurement, one needs to make wise choices about three key experimental parameters: the highest fringe frequency, the phase-shifting steps, and the fringe pattern sequence. However, there was very little research on how to optimize these parameters quantitatively, especially considering all three aspects from a theoretical and analytical perspective simultaneously. In this work, we propose a new scheme to determine simultaneously the optimal fringe frequency, phase-shifting steps and pattern sequence under multi-frequency TPU, robustly achieving high accuracy measurement by a minimum number of fringe frames. Firstly, noise models regarding phase-shifting algorithms as well as 3-D coordinates are established under a projector defocusing condition, which leads to the optimal highest fringe frequency for a FPP system. Then, a new concept termed frequency-to-frame ratio (FFR) that evaluates the magnitude of the contribution of each frame for TPU is defined, on which an optimal phase-shifting combination scheme is proposed. Finally, a judgment criterion is established, which can be used to judge whether the ratio between adjacent fringe frequencies is conducive to stably and efficiently unwrapping the phase. The proposed method provides a simple and effective theoretical framework to improve the accuracy, efficiency, and robustness of a practical FPP system in actual measurement conditions. The correctness of the derived models as well as the validity of the proposed schemes have been verified through extensive simulations and experiments. Based on a normal monocular 3-D FPP hardware system

  17. EMI Shielding Performance For Varies Frequency by Metal Plating on Mold Compound

    Directory of Open Access Journals (Sweden)

    Min Fee Tai

    2017-07-01

    Full Text Available Conformal metalization on mold compound offers new possibility for IC package design to improve features such as rigidization of the flexible core, heat sink capability, 3D-circuit patterning and the electromagnetic interference (EMI shielding. With the unique processes, the fabrication technology had enabled to achieve the high reliable performance and had passed the electrical test. Following research after the reliability concern, this paper further study the shielding effectiveness of varying coating thickness with respect to laboratory simulated EMI condition, using radio frequency from 10MHz to 5.8 GHz. Different metal namely pure nickel, nickel-phosphorous and pure plated copper are studied for their effectiveness of EMI sheilding. Our first result showed over 35-40dB of shielding effectiveness is achievable on high frequency 868-5800MHz. Nevertheless on low frequency of 10MHz, the shielding effectiveness achievement is below than 25dB. To overcome the shielding need for lower frequency, we further expanded our test by choosing ferromagentic material Nicke/Ironl-alloy in combination with thick copper plating. With this new metal combination, EMI shielding effectiveness for lower frequency is improved to 40dB.

  18. Data combinations accounting for LISA spacecraft motion

    International Nuclear Information System (INIS)

    Shaddock, Daniel A.; Tinto, Massimo; Estabrook, Frank B.; Armstrong, J.W.

    2003-01-01

    The laser interferometer space antenna is an array of three spacecraft in an approximately equilateral triangle configuration which will be used as a low-frequency gravitational wave detector. We present here new generalizations of the Michelson- and Sagnac-type time-delay interferometry data combinations. These combinations cancel laser phase noise in the presence of different up and down propagation delays in each arm of the array, and slowly varying systematic motion of the spacecraft. The gravitational wave sensitivities of these generalized combinations are the same as previously computed for the stationary cases, although the combinations are now more complicated. We introduce a diagrammatic representation to illustrate that these combinations are actually synthesized equal-arm interferometers

  19. A digital frequency stabilization system of external cavity diode laser based on LabVIEW FPGA

    Science.gov (United States)

    Liu, Zhuohuan; Hu, Zhaohui; Qi, Lu; Wang, Tao

    2015-10-01

    Frequency stabilization for external cavity diode laser has played an important role in physics research. Many laser frequency locking solutions have been proposed by researchers. Traditionally, the locking process was accomplished by analog system, which has fast feedback control response speed. However, analog system is susceptible to the effects of environment. In order to improve the automation level and reliability of the frequency stabilization system, we take a grating-feedback external cavity diode laser as the laser source and set up a digital frequency stabilization system based on National Instrument's FPGA (NI FPGA). The system consists of a saturated absorption frequency stabilization of beam path, a differential photoelectric detector, a NI FPGA board and a host computer. Many functions, such as piezoelectric transducer (PZT) sweeping, atomic saturation absorption signal acquisition, signal peak identification, error signal obtaining and laser PZT voltage feedback controlling, are totally completed by LabVIEW FPGA program. Compared with the analog system, the system built by the logic gate circuits, performs stable and reliable. User interface programmed by LabVIEW is friendly. Besides, benefited from the characteristics of reconfiguration, the LabVIEW program is good at transplanting in other NI FPGA boards. Most of all, the system periodically checks the error signal. Once the abnormal error signal is detected, FPGA will restart frequency stabilization process without manual control. Through detecting the fluctuation of error signal of the atomic saturation absorption spectrum line in the frequency locking state, we can infer that the laser frequency stability can reach 1MHz.

  20. Combination of precise GNSS orbit and clock solutions in a multi-constellation, multi-frequency environment

    Science.gov (United States)

    Ortiz Geist, Estefania

    2015-04-01

    Precise GNSS orbit and clock solutions are essential for the generation of the Terrestrial Reference Frame (TRF) and required for a broad variety of applications. Over the last decades the combination products of the International GNSS Service (IGS) have become the standard for all kinds of GNSS applications requiring highest accuracy. The emerging new GNSS constellations Galileo, BeiDou and the QZSS as well as the modernization of the already established GPS and GLONASS constellations will stimulate a new development in the GNSS data processing in order to gain be best benefit from the new signals and systems for geodetic and geodynamic applications. This introduces the question regarding the influence of this development on the orbit and clock products. What are the consequences for the consistency of the contributions from the Analysis Centres (ACs) of the IGS and how does the combination procedure need to react on his development? Another set of questions is related to the expected scenario in which not all IGS ACs will likely include all GNSS. The algorithm for the orbit and clock combination needs to be adapted for a multi-system combination to keep on one hand the internal consistency between the GNSS during the combination procedure but also consider the differences in the expected orbit qualities between the satellite systems (e.g., due to the number of satellites or network coverage). To investigate these questions ESOC and AIUB have agreed on a joint research fellowship for three years. The objective of this research is to analyse the capabilities and challenges when combining hybrid multi-GNSS solutions and to develop a concept, which compares and combines orbit and clock contributions to come up with a consistent, reliable, truly combined multi-GNSS combination product. Well-defined test scenarios shall be constructed and analysed based on the GNSS data processing software packages in the two institutions, namely "NAPEOS" and "Bernese GNSS Software

  1. Effects of word frequency and transitional probability on word reading durations of younger and older speakers

    NARCIS (Netherlands)

    Moers, C.; Meyer, A.S.; Janse, E.

    2017-01-01

    High-frequency units are usually processed faster than low-frequency units in language comprehension and language production. Frequency effects have been shown for words as well as word combinations. Word co-occurrence effects can be operationalized in terms of transitional probability (TP). TPs

  2. A frequency tracking synthesizer for beam diagnostic systems

    International Nuclear Information System (INIS)

    Peterson, D.; Marriner, J.

    1991-01-01

    In low and medium energy synchrotrons the beam revolution frequency changes by a large factor during the acceleration process. High production rates require that these machines cycle rapidly. In attempting to diagnose instabilities which develop during the acceleration process it is useful to be able to select some frequency segment between revolution harmonics for viewing. Most types of test equipment operating in the frequency domain, such as spectrum analyzers and network analyzers, are not suited to making direct measurements on such rapidly sweeping signals. Ideally, one would want to set the frequency frame of reference to the spot in the accelerating revolution harmonic domain where the measurements are to be made. A scheme using a direct digital synthesizer (DDS) was developed to provide this moving reference frame. This paper describes a synthesizer scheme combining digital and analog synthesizer techniques to allow tracking of signals during acceleration. Virtually any ratio of synthesizer to beam revolution frequency may be generated by this scheme. Details of hardware and measurement results are presented

  3. Study on cellular genotoxicities induced by alpha particles irradiation in combination with NNK treatment

    International Nuclear Information System (INIS)

    Li Ping; Yang Zhihua; Pan Xiujie; Cao Zhenshan; Mi Na; Chen Zhongmin; Liu Gang; Wei Han; Li Huiying; Zhu Maoxiang

    2006-01-01

    Objective: To investigate cellular genotoxicities of aplha particles irradiation in combination with NNK treatment. Methods: Exponentially growing immortalized human bronchial epithelial cells were divided into the normal control group (NC), alpha particles irradiation (α), NNK administration group (NNK), NNK administration (100 μg/ml) followed by alpha particles irradiation group (NNK + α), and alpha particles irradiation followed by NNK administration (100 μg/ml) group (μ + NNK). DNA damage were detected by single cell gel electrophoresis (SCGE); multinuclear cell assay was used to detect the frequency of the HPRT gene mutation; cell micronucleus frequency were detected by cytogenetic methods. Results: In the group exposed to both alpha particles irradiation and NNK, DNA damage, HPRT gene mutation frequency, and cell micronucleus frequency were significantly higher than those in the same dose groups irradiated with alpha particles or NNK administration alone. Subtracted the NNK effect, DNA damage, HPRT gene mutation frequency and cell micronucleus frequency in the group irradiated by alpha particles in combination with NNK administration were significantly higher than those of alpha particles irradiation alone. Conclusion: The genotoxicity of alpha particles irradiation in combination with NNK administration had synergistic effect. (authors)

  4. Multiharmonic Frequency-Chirped Transducers for Surface-Acoustic-Wave Optomechanics

    Science.gov (United States)

    Weiß, Matthias; Hörner, Andreas L.; Zallo, Eugenio; Atkinson, Paola; Rastelli, Armando; Schmidt, Oliver G.; Wixforth, Achim; Krenner, Hubert J.

    2018-01-01

    Wide-passband interdigital transducers are employed to establish a stable phase lock between a train of laser pulses emitted by a mode-locked laser and a surface acoustic wave generated electrically by the transducer. The transducer design is based on a multiharmonic split-finger architecture for the excitation of a fundamental surface acoustic wave and a discrete number of its overtones. Simply by introducing a variation of the transducer's periodicity p , a frequency chirp is added. This combination results in wide frequency bands for each harmonic. The transducer's conversion efficiency from the electrical to the acoustic domain is characterized optomechanically using single quantum dots acting as nanoscale pressure sensors. The ability to generate surface acoustic waves over a wide band of frequencies enables advanced acousto-optic spectroscopy using mode-locked lasers with fixed repetition rate. Stable phase locking between the electrically generated acoustic wave and the train of laser pulses is confirmed by performing stroboscopic spectroscopy on a single quantum dot at a frequency of 320 MHz. Finally, the dynamic spectral modulation of the quantum dot is directly monitored in the time domain combining stable phase-locked optical excitation and time-correlated single-photon counting. The demonstrated scheme will be particularly useful for the experimental implementation of surface-acoustic-wave-driven quantum gates of optically addressable qubits or collective quantum states or for multicomponent Fourier synthesis of tailored nanomechanical waveforms.

  5. An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

    Science.gov (United States)

    Kim, Woojae; Han, Tae Hwa; Kim, Hyun Jun; Park, Man Young; Kim, Ku Sang; Park, Rae Woong

    2011-06-01

    The mucociliary transport system is a major defense mechanism of the respiratory tract. The performance of mucous transportation in the nasal cavity can be represented by a ciliary beating frequency (CBF). This study proposes a novel method to measure CBF by using optical flow. To obtain objective estimates of CBF from video images, an automated computer-based image processing technique is developed. This study proposes a new method based on optical flow for image processing and peak detection for signal processing. We compare the measuring accuracy of the method in various combinations of image processing (optical flow versus difference image) and signal processing (fast Fourier transform [FFT] vs. peak detection [PD]). The digital high-speed video method with a manual count of CBF in slow motion video play, is the gold-standard in CBF measurement. We obtained a total of fifty recorded ciliated sinonasal epithelium images to measure CBF from the Department of Otolaryngology. The ciliated sinonasal epithelium images were recorded at 50-100 frames per second using a charge coupled device camera with an inverted microscope at a magnification of ×1,000. The mean square errors and variance for each method were 1.24, 0.84 Hz; 11.8, 2.63 Hz; 3.22, 1.46 Hz; and 3.82, 1.53 Hz for optical flow (OF) + PD, OF + FFT, difference image [DI] + PD, and DI + FFT, respectively. Of the four methods, PD using optical flow showed the best performance for measuring the CBF of nasal mucosa. The proposed method was able to measure CBF more objectively and efficiently than what is currently possible.

  6. An open trial of outpatient group therapy for bulimic disorders: combination program of cognitive behavioral therapy with assertive training and self-esteem enhancement.

    Science.gov (United States)

    Shiina, Akihiro; Nakazato, Michiko; Mitsumori, Makoto; Koizumi, Hiroki; Shimizu, Eiji; Fujisaki, Mihisa; Iyo, Masaomi

    2005-12-01

    The purposes of this study were to examine the therapeutic efficacy of combined group cognitive behavioral therapy (CGCBT) and to explore the characteristics of the patients who failed to complete it. Our group cognitive behavioral therapy combined with assertiveness training for alexithymia and self-esteem enhancement therapy were attended over a 10-week period. Twenty-five participants were enrolled in the study. The clinical symptoms were assessed before and after treatment, using rating scales including the Eating Disorder Inventory-2, the Bulimic Investigatory Test, Edinburgh, the Toronto Alexithymia Scale, the Rosenberg Self-Esteem Scale, and Global Assessment of Functioning. Sixteen participants (64%) completed the CGCBT program. Completion of the CGCBT resulted in significant improvements in reducing binge-eating behavior and improving social functioning. Eight patients (32%) significantly improved using the Clinical Global Impression Change (CGI-C). Stepwise logistic regression analysis of the results indicated that a lower age (P=0.04) and psychiatric comorbidity (P=0.06) were predictors of dropout from the CGCBT program. Our CGCBT program is a promising first-line treatment for bulimic outpatients. Lower age and the presence of comorbidity had effects on dropout rates.

  7. Impact of following self-management program for presternal keloids in combination of surgery and radiation therapy

    International Nuclear Information System (INIS)

    Miyashita, Tsuguhiro; Tateno, Atsushi; Kumazaki, Tatsuo; Hyakusoku, Hiko; Horiuchi, Junichi

    1999-01-01

    The combination therapy of surgical removal and the post-operative irradiation is thought as a gold standard therapy for intractable keloid. However, even when both methods were used, presternal keloids had a high incidence of recurrence. We reviewed 40 patients with presternal keloids who were treated with surgical removal and postoperative irradiation. Patients age range was 9 to 81 years (average 31.5 years, median 25 years), and the male to female ratio was 21:19. A comparative study was performed on recurrence rates by patients' age, sex, and keloid size, and with or without a self-management program that we designed. Overall relapse rate was 48%, which included minimal or partial recurrences. Of all recurrence, 57% occurred within six months and 84% within a year. The recurrence rates were 62% in male and 32% in female (P=0.057), 58% in those whose ages were less than thirty and 29% in those whose ages were thirty or greater (P=0.079), and 54% when the size of keloid was under 8 cm and 33% in 8 cm or more (P=0.240). A significant difference of recurrence rates was revealed just between the first half (67%) and the second half (32%) of therapeutic periods performed without or with the postoperative self-management program, respectively (P=0.028). It is suggested that the following application of our self-management program is useful for therapy in presternal keloids treated with surgical resection and radiation therapy. Keloids of young or male cases were exhibiting a tendency to recur. These patients should be treated with a strict self-management program. (author)

  8. Prediction of broadband ground-motion time histories: Hybrid low/high-frequency method with correlated random source parameters

    Science.gov (United States)

    Liu, P.; Archuleta, R.J.; Hartzell, S.H.

    2006-01-01

    We present a new method for calculating broadband time histories of ground motion based on a hybrid low-frequency/high-frequency approach with correlated source parameters. Using a finite-difference method we calculate low- frequency synthetics (structure. We also compute broadband synthetics in a 1D velocity model using a frequency-wavenumber method. The low frequencies from the 3D calculation are combined with the high frequencies from the 1D calculation by using matched filtering at a crossover frequency of 1 Hz. The source description, common to both the 1D and 3D synthetics, is based on correlated random distributions for the slip amplitude, rupture velocity, and rise time on the fault. This source description allows for the specification of source parameters independent of any a priori inversion results. In our broadband modeling we include correlation between slip amplitude, rupture velocity, and rise time, as suggested by dynamic fault modeling. The method of using correlated random source parameters is flexible and can be easily modified to adjust to our changing understanding of earthquake ruptures. A realistic attenuation model is common to both the 3D and 1D calculations that form the low- and high-frequency components of the broadband synthetics. The value of Q is a function of the local shear-wave velocity. To produce more accurate high-frequency amplitudes and durations, the 1D synthetics are corrected with a randomized, frequency-dependent radiation pattern. The 1D synthetics are further corrected for local site and nonlinear soil effects by using a 1D nonlinear propagation code and generic velocity structure appropriate for the site’s National Earthquake Hazards Reduction Program (NEHRP) site classification. The entire procedure is validated by comparison with the 1994 Northridge, California, strong ground motion data set. The bias and error found here for response spectral acceleration are similar to the best results that have been published by

  9. Calibration of semi-stochastic procedure for simulating high-frequency ground motions

    Science.gov (United States)

    Seyhan, Emel; Stewart, Jonathan P.; Graves, Robert

    2013-01-01

    Broadband ground motion simulation procedures typically utilize physics-based modeling at low frequencies, coupled with semi-stochastic procedures at high frequencies. The high-frequency procedure considered here combines deterministic Fourier amplitude spectra (dependent on source, path, and site models) with random phase. Previous work showed that high-frequency intensity measures from this simulation methodology attenuate faster with distance and have lower intra-event dispersion than in empirical equations. We address these issues by increasing crustal damping (Q) to reduce distance attenuation bias and by introducing random site-to-site variations to Fourier amplitudes using a lognormal standard deviation ranging from 0.45 for Mw  100 km).

  10. Simple method of generating and distributing frequency-entangled qudits

    Science.gov (United States)

    Jin, Rui-Bo; Shimizu, Ryosuke; Fujiwara, Mikio; Takeoka, Masahiro; Wakabayashi, Ryota; Yamashita, Taro; Miki, Shigehito; Terai, Hirotaka; Gerrits, Thomas; Sasaki, Masahide

    2016-11-01

    High-dimensional, frequency-entangled photonic quantum bits (qudits for d-dimension) are promising resources for quantum information processing in an optical fiber network and can also be used to improve channel capacity and security for quantum communication. However, up to now, it is still challenging to prepare high-dimensional frequency-entangled qudits in experiments, due to technical limitations. Here we propose and experimentally implement a novel method for a simple generation of frequency-entangled qudts with d\\gt 10 without the use of any spectral filters or cavities. The generated state is distributed over 15 km in total length. This scheme combines the technique of spectral engineering of biphotons generated by spontaneous parametric down-conversion and the technique of spectrally resolved Hong-Ou-Mandel interference. Our frequency-entangled qudits will enable quantum cryptographic experiments with enhanced performances. This distribution of distinct entangled frequency modes may also be useful for improved metrology, quantum remote synchronization, as well as for fundamental test of stronger violation of local realism.

  11. Core damage frequency observations and insights of LWRs based on the IPEs

    Energy Technology Data Exchange (ETDEWEB)

    Dingman, S.E.; Camp, A.L. [Sandia National Labs., Albuquerque, NM (United States); Drouin, M.T. [and others

    1995-04-01

    Seventy-eight plants are expected to submit Individual Plant Examinations (IPEs) for severe accident vulnerabilities to the US Nuclear Regulatory Commission (NRC). The majority of the plants have elected to perform full Level 1 probabilistic risk assessments (PRAs) to meet the intent of the IPEs. Because of this, it is possible to compare the results from the IPE submittals to determine general observations and {open_quotes}lessons learned{close_quotes} from the IPEs. The IPE Insights Program is performing this evaluation, and preliminary results are presented in this paper. The core damage frequency and core damage sequences are identified and compared for pressurized water reactors and boiling water reactors. Examination of the results indicates that variations among plant results are due to a combination of actual plant design/operational features and analysis approaches. The findings are consistent with previous NRC studies, such as WASH-1400 and NUREG-1150.

  12. Core damage frequency observations and insights of LWRs based on the IPEs

    International Nuclear Information System (INIS)

    Dingman, S.E.; Camp, A.L.; Drouin, M.T.; Kolaczkowski, A.; Darby, J.; LaChance, J.L.; Yakle, J.

    1995-01-01

    Seventy-eight plants are expected to submit Individual Plant Examinations (IPEs) for severe accident vulnerabilities to the U.S. Nuclear Regulatory Commission (NRC). The majority of the plants have elected to perform full Level 1 probabilistic risk assessments (PRAs) to meet the intent of the IPES. Because of this, it is possible to compare the results from the IPE submittals to determine general observations and open-quotes lessons learnedclose quotes from the IPES. The IPE Insights Program is performing this evaluation, and preliminary results are presented in this paper. The core damage frequency and core damage sequences are identified and compared for pressurized water reactors and boiling water reactors. Examination of the results indicates that variations among plant results are due to a combination of actual plant design/operational features and analysis approaches. The findings are consistent with previous NRC studies, such as WASH-1400 and NUREG-1 150

  13. Hybrid time/frequency domain modeling of nonlinear components

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz; Lykkegaard, Jan; Bak, Claus Leth

    2007-01-01

    This paper presents a novel, three-phase hybrid time/frequency methodology for modelling of nonlinear components. The algorithm has been implemented in the DIgSILENT PowerFactory software using the DIgSILENT Programming Language (DPL), as a part of the work described in [1]. Modified HVDC benchmark...

  14. Combined effect of carcinogenic n-nitrosodimethylamine precursors and fractioned γ-irradiation on tumor development in rats

    International Nuclear Information System (INIS)

    Galenko, P.M.; Nedopitanskaya, N.N.

    1996-01-01

    The influence of combined action of N-nitrosodimethylamine (NDMA) and fractioned γ-irradiation on tumor development in rats was investigated. Both the tumor frequency and tumor plurality coefficient have been studied for two types of treatment: precursors of NDMA (amidopyrine and/or sodium nitrite (SN)) alone and the combination 'precursors plus radiation'. Tumor frequency decreased by about 11% after combination of γ-irradiation and precursors in comparison with precursors alone. Nevertheless, treatment with SN and γ-irradiation did not change tumor frequency in comparison with SN alone. Irradiation of rats treated with precursors led to an increased tumor plurality coefficient

  15. Improving mental task classification by adding high frequency band information.

    Science.gov (United States)

    Zhang, Li; He, Wei; He, Chuanhong; Wang, Ping

    2010-02-01

    Features extracted from delta, theta, alpha, beta and gamma bands spanning low frequency range are commonly used to classify scalp-recorded electroencephalogram (EEG) for designing brain-computer interface (BCI) and higher frequencies are often neglected as noise. In this paper, we implemented an experimental validation to demonstrate that high frequency components could provide helpful information for improving the performance of the mental task based BCI. Electromyography (EMG) and electrooculography (EOG) artifacts were removed by using blind source separation (BSS) techniques. Frequency band powers and asymmetry ratios from the high frequency band (40-100 Hz) together with those from the lower frequency bands were used to represent EEG features. Finally, Fisher discriminant analysis (FDA) combining with Mahalanobis distance were used as the classifier. In this study, four types of classifications were performed using EEG signals recorded from four subjects during five mental tasks. We obtained significantly higher classification accuracy by adding the high frequency band features compared to using the low frequency bands alone, which demonstrated that the information in high frequency components from scalp-recorded EEG is valuable for the mental task based BCI.

  16. Effectiveness and Successful Program Elements of SOAR’s Afterschool Programs

    Directory of Open Access Journals (Sweden)

    Janet L. Johnson

    2007-03-01

    Full Text Available Project SOAR provided after-school programs that afforded expanded learning opportunities to help students succeed in local public schools and to contribute to the general welfare of the community. Program components focused on building students’ academic skills and positive attitudes, aided by teachers, mentors, parent education, and local agencies. Instructional programs were conducted to help reduce drug use and violence. Activities included academic assistance, technology training, mentoring, service learning projects, and education in life skills and the arts. Parent involvement was encouraged. Behavioral and academic outcomes—especially at the high school level—were analyzed to determine program effectiveness regarding academic achievement, dropout rates, and rates and frequency of suspensions. Successful program elements and strategies are noted.

  17. A simple, tunable, and highly sensitive radio-frequency sensor.

    Science.gov (United States)

    Cui, Yan; Sun, Jiwei; He, Yuxi; Wang, Zheng; Wang, Pingshan

    2013-08-05

    We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor ( Q eff ) of the sensor is as high as ∼3.8 × 10 6 with 200  μ l of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

  18. Microsoft C#.NET program and electromagnetic depth sounding for large loop source

    Science.gov (United States)

    Prabhakar Rao, K.; Ashok Babu, G.

    2009-07-01

    A program, in the C# (C Sharp) language with Microsoft.NET Framework, is developed to compute the normalized vertical magnetic field of a horizontal rectangular loop source placed on the surface of an n-layered earth. The field can be calculated either inside or outside the loop. Five C# classes with member functions in each class are, designed to compute the kernel, Hankel transform integral, coefficients for cubic spline interpolation between computed values and the normalized vertical magnetic field. The program computes the vertical magnetic field in the frequency domain using the integral expressions evaluated by a combination of straightforward numerical integration and the digital filter technique. The code utilizes different object-oriented programming (OOP) features. It finally computes the amplitude and phase of the normalized vertical magnetic field. The computed results are presented for geometric and parametric soundings. The code is developed in Microsoft.NET visual studio 2003 and uses various system class libraries.

  19. Frequency of interaction-mediated triggering of antibiotic production among soil bacteria

    Directory of Open Access Journals (Sweden)

    Olaf eTyc

    2014-10-01

    Full Text Available Certain bacterial species produce antimicrobial compounds only in the presence of a competing species. However little is known on the frequency of interaction-mediated induction of antibiotic compound production in natural communities of soil bacteria. Here we developed a high-throughput method to screen for the production of antimicrobial activity by monocultures and pair-wise combinations of 146 phylogenetically different bacteria isolated from similar soil habitats. Growth responses of two human pathogenic model organisms, Escherichia coli WA321 and Staphylococcus aureus 533R4, were used to monitor antimicrobial activity. From all isolates, 33% showed antimicrobial activity only in monoculture and 42% showed activity only when tested in interactions. More bacterial isolates were active against S. aureus than against E. coli. The frequency of interaction-mediated induction of antimicrobial activity was 6% (154 interactions out of 2798 indicating that only a limited set of species combinations showed such activity. The screening revealed also interaction-mediated suppression of antimicrobial activity for 22% of all combinations tested. Whereas all patterns of antimicrobial activity (non-induced production, induced production and suppression were seen for various bacterial classes, interaction-mediated induction of antimicrobial activity was more frequent for combinations of Flavobacteria and alpha- Proteobacteria. The results of our study give a first indication on the frequency of interference competitive interactions in natural soil bacterial communities which may forms a basis for selection of bacterial groups that are promising for the discovery of novel, cryptic antibiotics.

  20. 38 CFR 21.4279 - Combination correspondence-residence program.

    Science.gov (United States)

    2010-07-01

    ... VETERANS AFFAIRS (CONTINUED) VOCATIONAL REHABILITATION AND EDUCATION Administration of Educational.... (a) Requirements for pursuit. A program of education may be pursued partly in residence and partly by correspondence for the attainment of a predetermined and identified objective under the following conditions: (1...

  1. Linear Optimization of Frequency Spectrum Assignments Across System

    Science.gov (United States)

    2016-03-01

    selection tools, frequency allocation, transmission optimization, electromagnetic maneuver warfare, electronic protection, assignment model 15. NUMBER ...Characteristics Modeled ...............................................................29 Table 10.   Antenna Systems Modeled , Number of Systems and...surveillance EW early warning GAMS general algebraic modeling system GHz gigahertz IDE integrated development environment ILP integer linear program

  2. Combining science and practice in the Danish DK-SOFC program

    DEFF Research Database (Denmark)

    Knudsen, P.; Bagger, C.; Mogensen, Mogens Bjerg

    1994-01-01

    A three-year solid oxide fuel cells (SOFC) development program completed in 1992 has produced 10 cm2 cells with area-specific resistances in the range 0.25 to 0.40 OMEGA cm2 at 1000-degrees-C. Cathode and interconnect materials were produced in the program. Sintering of electrodes, electrolyte...

  3. Frequency of sarcopenia and associated factors among hospitalized elderly patients.

    Science.gov (United States)

    Martinez, Bruno Prata; Batista, Anne Karine Menezes Santos; Gomes, Isabela Barboza; Olivieri, Flávia Milholo; Camelier, Fernanda Warken Rosa; Camelier, Aquiles Assunção

    2015-05-06

    Sarcopenia is an important public health problem that affects mainly elders, and has negative consequences, such as disability and even death. Due to the lack of studies evaluating sarcopenia in elderly persons hospitalized in Brazil, the aim of the present study was to describe the frequency of sarcopenia and associated factors among elders in a hospital in the city of Salvador-Brazil. This cross-sectional study included 110 hospitalized elderly patients in a multi-specialty hospital in Salvador-BA, Brazil. Inclusion criteria: were elders aged ≥60 years between the first and fifth day of hospitalization; who were able to walk without external assistance; with medical permission to walk, and who did not take vasoactive and inotropic drugs. The diagnosis of sarcopenia was determined by combining the reduction in skeletal muscle mass with muscle weakness (women, sarcopenia was described in percentages with their respective confidence intervals and logistic regression was performed for multivariate analysis of factors associated with sarcopenia. Among the 110 patients included, the frequency of sarcopenia was 21.8%, with 10.0% being of the severe type. There was a predominance of clinical profile (59.1%), such as heart disease (20.0%), pneumonia (13.6%) and skin infections (9.1%), with a Charlson index of 5.4 ± 1.8. The factors associated with sarcopenia were age (OR = 1.14; 95% CI = 1.06 to 1.23), clinical profile on admission (OR = 5.15; 95% CI = 1.16-22.9) and smoking (OR = 7.8; 95% CI = 1.53-39.9). The frequency of sarcopenia in elderly hospitalized patients was high (1 in 5 elderly) and anthropometric equation can be a viable and inexpensive alternative to screening and programming intervention in this population.

  4. Cancellation of collisional frequency shifts in optical lattice clocks with Rabi spectroscopy

    International Nuclear Information System (INIS)

    Lee, Sangkyung; Park, Chang Yong; Lee, Won-Kyu; Yu, Dai-Hyuk

    2016-01-01

    We analyze both the s- and p-wave collision induced frequency shifts and propose an over-π pulse scheme to cancel the shifts in optical lattice clocks interrogated by a Rabi pulse. The collisional frequency shifts are analytically solved as a function of the pulse area and the inhomogeneity of the Rabi frequencies. Experimentally measured collisional frequency shifts in an Yb optical lattice clock are in good agreement with the analytical calculations. Based on our analysis, the over-π pulse combined with a small inhomogeneity below 0.1 allows a fractional uncertainty on a level of 10 −18 in both Sr and Yb optical lattice clocks by canceling the collisional frequency shift. (paper)

  5. Economic–environmental hierarchical frequency management of a droop-controlled islanded microgrid

    International Nuclear Information System (INIS)

    Rezaei, Navid; Kalantar, Mohsen

    2014-01-01

    Highlights: • Modeling the steady-state frequency of the droop-controlled microgrids. • Precise formulation the hierarchical control levels of islanded microgrids. • Economic–environmental frequency management using mixed-integer linear programming. • Proposing a novel objective function based on the microgrid daily frequency profile. • Scheduling primary and secondary control reserves using a stochastic optimization. - Abstract: This paper presents a novel energy management system (EMS) for a microgrid to enhance the power system security in a cost-effective manner. Small size of the islanded microgrids, high levels of intermittency and energy fluctuations, lower inertia potential of inverter-interfaced distributed energy resources (DERs) makes the frequency a vital factor in the microgrid energy management system that should be managed subject to the economic–environmental policies of the microgrid EMS. The proposed model is based on precise energy and reserve scheduling of the DERs in a droop-controlled islanded microgrid to manage the possible microgrid frequency excursions. The expected value of the microgrid frequency excursions stem from system power deviations is employed as a new objective function in this study, which is aimed to be minimized using a two stage stochastic mixed-integer linear programming method. In order to model the hierarchical control structure of the islanded microgrid, the frequency dependent behavior of the droop-controlled inverter-interfaced DERs is formulated thoroughly. The proposed model is applied to a typical microgrid test system. The primary and secondary frequency control reserves are appropriately scheduled over a 24 h period. A methodology based on the Monte-Carlo simulation strategy is adapted to generate some random scenarios corresponding to renewable generation variations, load consumption deviations and contingencies of line/unit outages. The generated scenarios are reduced and applied to the

  6. Temperature-insensitive laser frequency locking near absorption lines

    International Nuclear Information System (INIS)

    Kostinski, Natalie; Olsen, Ben A.; Marsland, Robert III; McGuyer, Bart H.; Happer, William

    2011-01-01

    Combined magnetically induced circular dichroism and Faraday rotation of an atomic vapor are used to develop a variant of the dichroic atomic vapor laser lock that eliminates lock sensitivity to temperature fluctuations of the cell. Operating conditions that eliminate first-order sensitivity to temperature fluctuations can be determined by low-frequency temperature modulation. This temperature-insensitive gyrotropic laser lock can be accurately understood with a simple model, that is in excellent agreement with observations in potassium vapor at laser frequencies in a 2 GHz range about the 770.1 nm absorption line. The methods can be readily adapted for other absorption lines.

  7. [The application of combined physiotherapeutic methods for the complex treatment of patients with dyscirculatory encephalopathy].

    Science.gov (United States)

    Shiman, A G; Klocheva, E G; Kaiumov, S F; Shoferova, S D; Zhukova, M V

    2012-01-01

    This article reports the results of applying basic pharmacotherapy (enalapril, cytoflavin) and its combination with physical factors (transcranial electrostimulation, combined application oftranscranial electrostimulation and low-frequency magnetic therapy) in the complex treatment of patients with stage I-II dyscirculatory encephalopathy. The study has demonstrated that the combined treatment with cytoflavin, enalapril, transcranial electrostimulation and low-frequency magnetic therapy produced the most pronounced therapeutic effect (82.5%), as confirmed by positive dynamics of clinical and functional parameters.

  8. Demonstration of a tunable two-frequency projected fringe pattern with acousto-optic deflectors

    International Nuclear Information System (INIS)

    Dupont, S.; Kastelik, J. C.

    2008-01-01

    We report on a fringe projector for three-dimensional shape measurement. The developed instrument is able to project a two-frequency fringe pattern, each frequency is independently controlled by electronics. Moreover, each phase of the two fringe patterns is also independently adjusted. The projection system is based on the use of a pair of custom large bandwidth (40 MHz) and high efficiency (60%) TeO 2 deflectors. The developed instrument offers the combined advantages of a static two-frequency fringe projector and of a tunable single frequency fringe projector

  9. and improvement of bowel function by increasing stool frequency pursuant to Article 13(5) of Regulation (EC) No 1924/2006

    DEFF Research Database (Denmark)

    Tetens, Inge

    2014-01-01

    to a combination of Bifidobacterium longum LA 101, Lactobacillus helveticus LA 102, Lactococcus lactis LA 103 and Streptococcus thermophilus LA 104 and improvement of bowel function by increasing stool frequency. The food that is the subject of the health claim is a combination of four bacterial strains—B. longum...... proposed by the applicant is "improves stool frequency". The Panel considers that improvement of bowel function by increasing stool frequency, provided that it does not result in diarrhoea, is a beneficial physiological effect. The Panel considers that the human study provided for the substantiation...... of the claim did not find an increase in stool frequency following consumption of a combination of the bacterial strains which is the subject of the claim. The Panel concludes that a cause and effect relationship has not been established between the consumption of a combination of B. longum LA 101, L...

  10. Control of high frequency microactuators using active structures

    International Nuclear Information System (INIS)

    Kreth, P A; Alvi, F S; Reese, B M; Oates, W S

    2015-01-01

    A fluidically driven microactuator that generates supersonic, pulsed microjets has been implemented with smart materials to actively and precisely control the frequency of the microjets in a closed-loop manner. Since this actuator relies on a number of microscale flow and acoustic phenomena to produce the pulsed microjets, its resonant frequency is determined by its geometry and other flow parameters. The design discussed in this paper integrates piezoelectric stacks by connecting them to movable sidewalls within the actuator such that the microactuator's internal geometry can be controlled by varying the voltage across the piezo-stacks. An open-loop control scheme demonstrates the frequency modulation capabilities that are enabled with this design: very large frequency deviations (up to ±500 Hz) around the actuator design frequency are attained at very high rates (up to 1 kHz). Closed-loop control of the microactuator's frequency was also demonstrated, and the results indicate that (combined with appropriate sensors) this actuator could be used effectively for active, feedback control in high-speed, resonance-dominated flowfields. This proof of concept study clearly illustrates the ability of this robust and compact actuator to produce perturbations that can be modulated and controlled based on the desired control objective. (paper)

  11. Radio-frequency quadrupole: a new linear accelerator

    International Nuclear Information System (INIS)

    Stokes, R.H.; Wangler, T.P.; Crandall, K.R.

    1981-01-01

    In many Laboratories, great emphasis now is placed on the development of linear accelerators with very large ion currents. To achieve this goal, a primary concern must be the low-velocity part of the accelerator, where the current limit is determined and where most of the emittance growth occurs. The use of magnetic focusing, the conflicting requirements in the choice of linac frequency, and the limitations of high-voltage dc injectors, have tended to produce low-velocity designs that limit overall performance. The radio-frequency quadrupole (RFQ) linear accelerator, invented in the Soviet Union and developed at Los Alamos, offers an attractive solution to many of these low-velocity problems. In the RFQ, the use of RF electric fields for radial focusing, combined with special programming of the bunching, allows high-current dc beams to be captured and accelerated with only small beam loss and low radial emittance growth. Advantages of the RFQ linac include a low injection energy (20 to 50 keV for protons) and a final energy high enough so the beam can be further accelerated with high efficiency in a Wideroee or Alvarez linac. These properties have been confirmed at Los Alamos in a highly successful experimental test performed during the past year. The success of this test and the advances in RFQ design procedures have led to the adoption of this linac for a wide range of applications. The beam-dynamics parameters of three RFQ systems are described. These are the final design for the protytype test of the Fusion Materials Irradiation Test (FMIT) accelerator, the final design for the prototype test of the Pion Generator for Medical Irradiations (PIGMI), and an improved low-velocity linac for heavy ion fusion

  12. Mercury Trapped Ion Frequency Standard for Ultra-Stable Reference Applications

    Science.gov (United States)

    Burt, Eric A. (Inventor); Hamell, Robert L. (Inventor); Tucker, Blake C. (Inventor); Larsen, Kameron (Inventor); Tjoelker, Robert L. (Inventor)

    2017-01-01

    An atomic clock including an ion trap assembly, a C-field coil positioned for generating a first magnetic field in the interrogation region of the ion trap assembly, a compensation coil positioned for generating a second magnetic field in the interrogation region, wherein the combination of the first and second magnetic fields produces an ion number-dependent second order Zeeman shift (Zeeman shift) in the resonance frequency that is opposite in sign to an ion number-dependent second order Doppler shift (Doppler shift) in the resonance frequency, the C-field coil has a radius selected using data indicating how changes in the radius affect an ion-number-dependent shift in the resonance frequency, such that a difference in magnitude between the Doppler shift and the Zeeman shift is controlled or reduced, and the resonance frequency, including the adjustment by the Zeeman shift, is used to obtain the frequency standard.

  13. A new time-frequency method for identification and classification of ball bearing faults

    Science.gov (United States)

    Attoui, Issam; Fergani, Nadir; Boutasseta, Nadir; Oudjani, Brahim; Deliou, Adel

    2017-06-01

    In order to fault diagnosis of ball bearing that is one of the most critical components of rotating machinery, this paper presents a time-frequency procedure incorporating a new feature extraction step that combines the classical wavelet packet decomposition energy distribution technique and a new feature extraction technique based on the selection of the most impulsive frequency bands. In the proposed procedure, firstly, as a pre-processing step, the most impulsive frequency bands are selected at different bearing conditions using a combination between Fast-Fourier-Transform FFT and Short-Frequency Energy SFE algorithms. Secondly, once the most impulsive frequency bands are selected, the measured machinery vibration signals are decomposed into different frequency sub-bands by using discrete Wavelet Packet Decomposition WPD technique to maximize the detection of their frequency contents and subsequently the most useful sub-bands are represented in the time-frequency domain by using Short Time Fourier transform STFT algorithm for knowing exactly what the frequency components presented in those frequency sub-bands are. Once the proposed feature vector is obtained, three feature dimensionality reduction techniques are employed using Linear Discriminant Analysis LDA, a feedback wrapper method and Locality Sensitive Discriminant Analysis LSDA. Lastly, the Adaptive Neuro-Fuzzy Inference System ANFIS algorithm is used for instantaneous identification and classification of bearing faults. In order to evaluate the performances of the proposed method, different testing data set to the trained ANFIS model by using different conditions of healthy and faulty bearings under various load levels, fault severities and rotating speed. The conclusion resulting from this paper is highlighted by experimental results which prove that the proposed method can serve as an intelligent bearing fault diagnosis system.

  14. A combined wave distribution function and stability analysis of Viking particle and low-frequency wave data

    International Nuclear Information System (INIS)

    Oscarsson, T.E.; Roennmark, K.G.

    1990-01-01

    In this paper the authors present an investigation of low-frequency waves observed on auroral field lines below the acceleration region by the Swedish satellite Viking. The measured frequency spectra are peaked at half the local proton gyrofrequency, and the waves are observed in close connection with precipitating electrons. In order to obtain information about the distribution of wave energy in wave vector space, they reconstruct the wave distribution function (WDF) from observed spectral densities. They use a new scheme that allows them to reconstruct simultaneously the WDF over a broad frequency band. The method also makes it possible to take into account available particle observations as well as Doppler shifts caused by the relative motion between the plasma and the satellite. The distribution of energy in wave vector space suggested by the reconstructed WDF is found to be consistent with what is expected from a plasma instability driven by the observed precipitating electrons. Furthermore, by using UV images obtained on Viking, they demonstrate that the wave propagation directions indicated by the reconstructed WDFs are consistent with a simple model of the presumed wave source in the electron precipitation region

  15. Biological and genetic effects of combined treatments of sodium azide, gamma rays and EMS in barley

    International Nuclear Information System (INIS)

    Cheng, X.Y.; Gao, M.W.

    1988-01-01

    Dry seeds of diploid barley were subjected to mutagenic treatments of sodium azide, gamma rays and EMS alone or in combination. Damage (reduction in seedling height, plant height and fertility), the frequency of chimeras in the M1 generation, and the frequency of chlorophyll-deficient mutations as well as morphological mutations in the M2 generation induced by combined treatments were greater than those by either of the single treatments. Synergistic increase in the frequency of chimeras, chlorphyll-deficient mutations and morphological mutations were observed in both sodium azide post-irradiation treatments and pre-EMS treatments; interaction among the mutagens in the treatment combinations on M1 damage was generally subtractive. An 8- to 16-hr soaking period of irradiated seeds in distilled water prior to sodium azide treatment significantly increased chlorophyll mutation frequency, as compared to that from the non-soaking treatment. Damage and frequency of chimeras, chlorophyll mutations and morphological mutations were consistently reduced by the soaking treatment in sodium azide plus EMS treatments. (author)

  16. CNV amplitude as a neural correlate for stuttering frequency: A case report of acquired stuttering.

    Science.gov (United States)

    Vanhoutte, Sarah; Van Borsel, John; Cosyns, Marjan; Batens, Katja; van Mierlo, Pieter; Hemelsoet, Dimitri; Van Roost, Dirk; Corthals, Paul; De Letter, Miet; Santens, Patrick

    2014-11-01

    A neural hallmark of developmental stuttering is abnormal articulatory programming. One of the neurophysiological substrates of articulatory preparation is the contingent negative variation (CNV). Unfortunately, CNV tasks are rarely performed in persons who stutter and mainly focus on the effect of task variation rather than on interindividual variation in stutter related variables. However, variations in motor programming seem to be related to variation in stuttering frequency. The current study presents a case report of acquired stuttering following stroke and stroke related surgery in the left superior temporal gyrus. A speech related CNV task was administered at four points in time with differences in stuttering severity and frequency. Unexpectedly, CNV amplitudes at electrode sites approximating bilateral motor and left inferior frontal gyrus appeared to be inversely proportional to stuttering frequency. The higher the stuttering frequency, the lower the activity for articulatory preparation. Thus, the amount of disturbance in motor programming seems to determine stuttering frequency. At right frontal electrodes, a relative increase in CNV amplitude was seen at the test session with most severe stuttering. Right frontal overactivation is cautiously suggested to be a compensation strategy. In conclusion, late CNV amplitude elicited by a relatively simple speech task seems to be able to provide an objective, neural correlate of stuttering frequency. The present case report supports the hypothesis that motor preparation has an important role in stuttering. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Feasibility of a combined aerobic and strength training program and its effects on cognitive and physical function in institutionalized dementia patients. A pilot study

    NARCIS (Netherlands)

    Bossers, Willem J R; Scherder, Erik J A; Boersma, Froukje; Hortobágyi, Tibor; van der Woude, Lucas H V; van Heuvelen, Marieke J G

    2014-01-01

    Objectives: We examined the feasibility of a combined aerobic and strength training program in institutionalized dementia patients and studied the effects on cognitive and physical function. Methods: Thirty-three patients with dementia, recruited from one nursing home, participated in this

  18. Feasibility of a Combined Aerobic and Strength Training Program and Its Effects on Cognitive and Physical Function in Institutionalized Dementia Patients. A Pilot Study

    NARCIS (Netherlands)

    Bossers, W.J.R; Scherder, E.J.A.; Boersma, F.; Hortobágyi, T.; van der Woude, L.H.V.; van Heuvelen, M.J.G.

    2014-01-01

    Objectives: We examined the feasibility of a combined aerobic and strength training program in institutionalized dementia patients and studied the effects on cognitive and physical function. Methods: Thirty-three patients with dementia, recruited from one nursing home, participated in this

  19. Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers

    Science.gov (United States)

    Simons, Rainee N.; Chevalier, Christine T.; Wintucky, Edwin G.; Freeman, Jon C.

    2010-01-01

    The design, simulation, and characterization of a novel Ka-band (32.05 0.25 GHz) rectangular waveguide two-way branch-line hybrid unequal power combiner (with port impedances matched to that of a standard WR-28 waveguide) has been created to combine input signals, which are in phase and with an amplitude ratio of two. The measured return loss and isolation of the branch-line hybrid are better than 22 and 27 dB, respectively. The measured combining efficiency is 92.9 percent at the center frequency of 32.05 GHz. This circuit is efficacious in combining the unequal output power from two Ka-band GaAs pseudomorphic high electron mobility transistor (pHEMT) monolithic microwave integrated circuit (MMIC) power amplifiers (PAs) with high efficiency. The component parts include the branch-line hybrid-based power combiner and the MMIC-based PAs. A two-way branch-line hybrid is a four-port device with all ports matched; power entering port 1 is divided in phase, and into the ratio 2:1 between ports 3 and 4. No power is coupled to port 2. MMICs are a type of integrated circuit fabricated on GaAs that operates at microwave frequencies, and performs the function of signal amplification. The power combiner is designed to operate over the frequency band of 31.8 to 32.3 GHz, which is NASA's deep space frequency band. The power combiner would have an output return loss better than 20 dB. Isolation between the output port and the isolated port is greater than 25 dB. Isolation between the two input ports is greater than 25 dB. The combining efficiency would be greater than 90 percent when the ratio of the two input power levels is two. The power combiner is machined from aluminum with E-plane split-block arrangement, and has excellent reliability. The flexibility of this design allows the combiner to be customized for combining the power from MMIC PAs with an arbitrary power output ratio. In addition, it allows combining a low-power GaAs MMIC with a high-power GaN MMIC. The arbitrary

  20. Measurement of a discontinuous object based on a dual-frequency grating

    Institute of Scientific and Technical Information of China (English)

    Qiao Nao-Sheng; Cai Xin-Hua; Yao Chun-Mei

    2009-01-01

    The dual-frequency grating measurement theory is proposed in order to carry out the measurement of a discontinuous object. Firstly, the reason why frequency spectra are produced by low frequency gratings and high frequency gratings in the field of frequency is analysed, and the relationship between the wrapped-phase and the unwrappingphase is discussed. Secondly, a method to combine the advantages of the two kinds of gratings is proposed: one stripe is produced in the mutation part of the object measured by a suitable low frequency grating designed by MATLAB, then the phase produced by the low frequency grating need not be unfolded. The integer series of stripes is produced by a high frequency grating designed by MATLAB based on the frequency ratio of the two kinds of gratings and the high frequency wrapped-phase, and the high frequency unwrapping-phase is then obtained. In order to verify the correctness of the theoretical analysis, a steep discontinuous object of 600×600 pixels and 10.00 mm in height is simulated and a discontinuous object of ladder shape which is 32.00 mm in height is used in experiment. Both the simulation and the experiment can restore the discontinuous object height accurately by using the dual-frequency grating measurement theory.

  1. Frequency modulation detection atomic force microscopy in the liquid environment

    Science.gov (United States)

    Jarvis, S. P.; Ishida, T.; Uchihashi, T.; Nakayama, Y.; Tokumoto, H.

    True atomic resolution imaging using frequency modulation detection is already well established in ultra-high vacuum. In this paper we demonstrate that it also has great potential in the liquid environment. Using a combination of magnetic activation and high-aspect-ratio carbon nanotube probes, we show that imaging can be readily combined with point spectroscopy, revealing both the tip-sample interaction and the structure of the intermediate liquid.

  2. Elimination of frequency noise from groundwater measurements

    International Nuclear Information System (INIS)

    Chien, Y.M.; Bryce, R.W.; Strait, S.R.; Yeatman, R.A.

    1986-04-01

    Groundwater response to atmospheric fluctuation can be effectively removed from downhole-pressure records using the systematic approach. The technique is not as successful for removal of earth tides, due to a probable discrepancy between the actual earth tide and the theoretical earth tide. The advantage of the systematic technique is that a causative relationship is established for each component of the pressure response removed. This concept of data reduction is easily understood and well accepted. The disadvantage is that a record of the stress causing the pressure fluctuation must be obtained. This may be done by monitoring or synthesizing the stress. Frequency analysis offers a simpler way to eliminate the undesirable hydrologic fluctuations from the downhole pressure. Frequency analysis may prove to be impractical if the fluctuations being removed have broadband characteristics. A combination of the two techniques, such as eliminating the atmospheric effect with the systematic method and the earth-tide fluctuations with the frequency method, is the most effective and efficient approach

  3. The CRAFT Fortran Programming Model

    Directory of Open Access Journals (Sweden)

    Douglas M. Pase

    1994-01-01

    Full Text Available Many programming models for massively parallel machines exist, and each has its advantages and disadvantages. In this article we present a programming model that combines features from other programming models that (1 can be efficiently implemented on present and future Cray Research massively parallel processor (MPP systems and (2 are useful in constructing highly parallel programs. The model supports several styles of programming: message-passing, data parallel, global address (shared data, and work-sharing. These styles may be combined within the same program. The model includes features that allow a user to define a program in terms of the behavior of the system as a whole, where the behavior of individual tasks is implicit from this systemic definition. (In general, features marked as shared are designed to support this perspective. It also supports an opposite perspective, where a program may be defined in terms of the behaviors of individual tasks, and a program is implicitly the sum of the behaviors of all tasks. (Features marked as private are designed to support this perspective. Users can exploit any combination of either set of features without ambiguity and thus are free to define a program from whatever perspective is most appropriate to the problem at hand.

  4. Tamsulosin and Solifenacin in the Treatment of Benign Prostatic Hyperplasia in combination with overactive bladder.

    Science.gov (United States)

    Wang, Hui; Chang, Yanhua; Liang, Hui

    2017-01-01

    To analyze the clinical effect of tamsulosin and Solifenacin in the treatment of benign prostatic hyperplasia in combination with overactive bladder and its safety. Another objective was to investigate the clinical effect and safety of mega dose of tamsulosin in the treatment of benign prostatic hyperplasia in combination with overactive bladder. One hundred and twenty-four patients who were admitted to the Dept. of Urology at Binzhou People's Hospital, , China with confirmed benign prostatic hyperplasia (BPH) with overactive bladder were randomly divided into two groups. Sixty-two patients in the control group were treated with tamsulosin, while sixty-two patients in the observation group were treated with tamsulosin in combination with solifenacin. The treatment of both groups lasted for 12 weeks. The effect and adverse reaction were compared between the two groups. The international prostate symptom score (IPSS), quality of life (QOL), and overactive bladder symptom score (OABSS), Q max , pulmonary vascular resistance (PVR), daytime urination frequency, urgent urination frequency, urge urinary incontinence frequency and night urinary frequency of both groups improved after treatment, and the difference had statistical significance (P0.05). Treating benign prostatic hyperplasia in combination with overactive bladder with tamsulosin in combination with solifenacin is more effective than tamsulosin, without significantly increasing adverse reactions. Thus the therapy is worth clinical promotion.

  5. Optimal Frequency Ranges for Sub-Microsecond Precision Pulsar Timing

    Science.gov (United States)

    Lam, Michael Timothy; McLaughlin, Maura; Cordes, James; Chatterjee, Shami; Lazio, Joseph

    2018-01-01

    Precision pulsar timing requires optimization against measurement errors and astrophysical variance from the neutron stars themselves and the interstellar medium. We investigate optimization of arrival time precision as a function of radio frequency and bandwidth. We find that increases in bandwidth that reduce the contribution from receiver noise are countered by the strong chromatic dependence of interstellar effects and intrinsic pulse-profile evolution. The resulting optimal frequency range is therefore telescope and pulsar dependent. We demonstrate the results for five pulsars included in current pulsar timing arrays and determine that they are not optimally observed at current center frequencies. We also find that arrival-time precision can be improved by increases in total bandwidth. Wideband receivers centered at high frequencies can reduce required overall integration times and provide significant improvements in arrival time uncertainty by a factor of $\\sim$$\\sqrt{2}$ in most cases, assuming a fixed integration time. We also discuss how timing programs can be extended to pulsars with larger dispersion measures through the use of higher-frequency observations.

  6. Evaluation of a combined laser-radio frequency device (Polaris WR) for the nonablative treatment of facial wrinkles.

    Science.gov (United States)

    Kulick, Michael

    2005-06-01

    Nonablative wrinkle reduction or skin tightening is desired by individuals who, ideally, hope to have the skin improvement associated with chemical or laser ablative techniques but without the undesirable recovery process. Electro-optical synergy (ELOS) technology that combines radio frequency (RF) and diode laser energy (900 nm) was used to treat 15 patients in this IRB sanctioned study. Energy settings were based on the depth of wrinkles (the greater the depth and concentration of wrinkles, the higher the RF setting) and ranged from 50-100 J/cm2 RF and 15 J/cm2 for the optical, laser component. Patients received three full-face treatments, and results were evaluated by comparison of standardized photographs and patient questionnaire given prior to each treatment and one month after the third treatment. The primary investigator and three other "blinded" physicians evaluated these photographs using Fitzpatrick's wrinkle classification to assess the improvement, if any, between the initial and final visit. Eight patients completed the study. Explanation for the exclusion of the remaining six patients were: one decided to have surgery, two felt the treatment was too painful, and three moved out of the area. Following treatment, all patients had mild swelling (resolved skin hyperemia (resolved skin wrinkles (range 14%-32%). There were no adverse side effects. The major concern of the patients was the discomfort associated with the treatment. As part of an FDA investigation to assess efficacy, long-term follow-up was not a part of this study protocol.

  7. Time-frequency analysis of band-limited EEG with BMFLC and Kalman filter for BCI applications

    Science.gov (United States)

    2013-01-01

    Background Time-Frequency analysis of electroencephalogram (EEG) during different mental tasks received significant attention. As EEG is non-stationary, time-frequency analysis is essential to analyze brain states during different mental tasks. Further, the time-frequency information of EEG signal can be used as a feature for classification in brain-computer interface (BCI) applications. Methods To accurately model the EEG, band-limited multiple Fourier linear combiner (BMFLC), a linear combination of truncated multiple Fourier series models is employed. A state-space model for BMFLC in combination with Kalman filter/smoother is developed to obtain accurate adaptive estimation. By virtue of construction, BMFLC with Kalman filter/smoother provides accurate time-frequency decomposition of the bandlimited signal. Results The proposed method is computationally fast and is suitable for real-time BCI applications. To evaluate the proposed algorithm, a comparison with short-time Fourier transform (STFT) and continuous wavelet transform (CWT) for both synthesized and real EEG data is performed in this paper. The proposed method is applied to BCI Competition data IV for ERD detection in comparison with existing methods. Conclusions Results show that the proposed algorithm can provide optimal time-frequency resolution as compared to STFT and CWT. For ERD detection, BMFLC-KF outperforms STFT and BMFLC-KS in real-time applicability with low computational requirement. PMID:24274109

  8. Airbreathing combined cycle engine systems

    Science.gov (United States)

    Rohde, John

    1992-01-01

    The Air Force and NASA share a common interest in developing advanced propulsion systems for commercial and military aerospace vehicles which require efficient acceleration and cruise operation in the Mach 4 to 6 flight regime. The principle engine of interest is the turboramjet; however, other combined cycles such as the turboscramjet, air turborocket, supercharged ejector ramjet, ejector ramjet, and air liquefaction based propulsion are also of interest. Over the past months careful planning and program implementation have resulted in a number of development efforts that will lead to a broad technology base for those combined cycle propulsion systems. Individual development programs are underway in thermal management, controls materials, endothermic hydrocarbon fuels, air intake systems, nozzle exhaust systems, gas turbines and ramjet ramburners.

  9. On the Capacity of a GSM Frequency Hopping network with Intelligent Underlayer-Overlayer

    DEFF Research Database (Denmark)

    Nielsen, Thomas Toftegaard; Wigard, Jeroen; Mogensen, Preben Elgaard

    1997-01-01

    . By combining this reuse partitioning with frequency hopping, an increase in the network capacity in terms of carried traffic per cell is achieved. Simulations have indicated that for slow moving mobiles a gain of approximately 35% is achieved by this new feature when compared with a frequency hopping network...

  10. Advanced Time-Frequency Representation in Voice Signal Analysis

    Directory of Open Access Journals (Sweden)

    Dariusz Mika

    2018-03-01

    Full Text Available The most commonly used time-frequency representation of the analysis in voice signal is spectrogram. This representation belongs in general to Cohen's class, the class of time-frequency energy distributions. From the standpoint of properties of the resolution spectrogram representation is not optimal. In Cohen class representations are known which have a better resolution properties. All of them are created by smoothing the Wigner-Ville'a (WVD distribution characterized by the best resolution, however, the biggest harmful interference. Used smoothing functions decide about a compromise between the properties of resolution and eliminating harmful interference term. Another class of time-frequency energy distributions is the affine class of distributions. From the point of view of readability of analysis the best properties are known so called Redistribution of energy caused by the use of a general methodology referred to as reassignment to any time-frequency representation. Reassigned distributions efficiently combine a reduction of the interference terms provided by a well adapted smoothing kernel and an increased concentration of the signal components.

  11. An abstract model of rogue code insertion into radio frequency wireless networks. The effects of computer viruses on the Program Management Office

    Science.gov (United States)

    Feudo, Christopher V.

    1994-04-01

    This dissertation demonstrates that inadequately protected wireless LANs are more vulnerable to rogue program attack than traditional LANs. Wireless LANs not only run the same risks as traditional LANs, but they also run additional risks associated with an open transmission medium. Intruders can scan radio waves and, given enough time and resources, intercept, analyze, decipher, and reinsert data into the transmission medium. This dissertation describes the development and instantiation of an abstract model of the rogue code insertion process into a DOS-based wireless communications system using radio frequency (RF) atmospheric signal transmission. The model is general enough to be applied to widely used target environments such as UNIX, Macintosh, and DOS operating systems. The methodology and three modules, the prober, activator, and trigger modules, to generate rogue code and insert it into a wireless LAN were developed to illustrate the efficacy of the model. Also incorporated into the model are defense measures against remotely introduced rogue programs and a cost-benefit analysis that determined that such defenses for a specific environment were cost-justified.

  12. A Compact Frequency Reconfigurable Hybrid DRA for LTE/Wimax Applications

    Directory of Open Access Journals (Sweden)

    Sajid Aqeel

    2017-01-01

    Full Text Available A compact hybrid antenna structure with frequency reconfiguration capabilities is presented in this article. The proposed design employs a combination of a rectangular DR element and a coupling slot on the structure’s ground plane (GP. The slot shifts the fundamental DRA mode by introducing a slow wave effect and its resonant behavior helps to achieve an omnidirectional pattern at low frequencies. The slot is loaded with a series of PIN diode switches whose ON/OFF combinations alter the effective slot length. Slot loading with PIN diodes results in frequency reconfiguration of the proposed structure with a large tuning range of 76.2% (between 1.73 and 3.86 GHz. A parametric analysis was performed to investigate the effects of slot length, width, and position on the reflection coefficients of the proposed structure. A prototype of the proposed design was fabricated and results were measured. The measured results show a close agreement with the simulated ones. The proposed design is suitable for DCS 1800 MHz, PCS 1900 MHZ, UMTS, LTE 2500–2700 MHz, and Wimax 3.5 GHz.

  13. Validation of a simplified food frequency questionnaire for the assessment of dietary habits in Iranian adults: Isfahan Healthy Heart Program, Iran

    Directory of Open Access Journals (Sweden)

    Noushin Mohammadifard

    2015-03-01

    Full Text Available BACKGROUND: Dietary assessment is the first step of dietary modification in community-based interventional programs. This study was performed to validate a simple food frequency questionnaire (SFFQ for assessment of selected food items in epidemiological studies with a large sample size as well as community trails. METHODS: This validation study was carried out on 264 healthy adults aged ≥ 41 years old living in 3 district central of Iran, including Isfahan, Najafabad, and Arak. Selected food intakes were assessed using a 48-item food frequency questionnaire (FFQ. The FFQ was interviewer-administered, which was completed twice; at the beginning of the study and 2 weeks thereafter. The validity of this SFFQ was examined compared to estimated amount by single 24 h dietary recall and 2 days dietary record. Validation of the FFQ was determined using Spearman correlation coefficients between daily frequency consumption of food groups as assessed by the FFQ and the qualitative amount of daily food groups intake accessed by dietary reference method was applied to evaluate validity. Intraclass correlation coefficients (ICC were used to determine the reproducibility. RESULTS: Spearman correlation coefficient between the estimated amount of food groups intake by examined and reference methods ranged from 0.105 (P = 0.378 in pickles to 0.48 (P < 0.001 in plant protein. ICC for reproducibility of FFQ were between 0.47-0.69 in different food groups (P < 0.001. CONCLUSION: The designed SFFQ has a good relative validity and reproducibility for assessment of selected food groups intake. Thus, it can serve as a valid tool in epidemiological studies and clinical trial with large participants.   

  14. Frequency regulated compact screw compressors. The new solution; Drehzahlgeregelte Kompakt-Schraubenverdichter. Die neue Loesung

    Energy Technology Data Exchange (ETDEWEB)

    Juergensen, Heinz [BITZER Kuehlmaschinenbau GmbH, Sindelfingen (Germany)

    2012-07-01

    Compact screw compressors have been used for many years in liquid chilling packages for comfort air conditioners, process cooling or heat pumps with mechanical power control. Standard frequency inverters offer the possibility to adjust the performance of a conventional screw compressor, piston compressor or scroll compressor in a small range of frequency. Furthermore, frequency inverters contain a number of additional functions. This combination of existing frequency inverters and compressors - as actually offered in many cases - allows only a limited improvement of the part-load performance in the system. Due to the high cost for the frequency inverters, this combination becomes economically questionable. An integrated package of newly developed compact screw compressors and a specially developed liquid-cooled frequency inverter is required in order to come to a new level of system efficiency at part load. In addition to the increased control range of the compressor, new possibilities can be opened up in terms of application and communication. The monitoring of various values such as the compliance with the application limits for pressure and temperature and especially the early warning against exceedance facilitates a more simply implementation of a secure machine because the setting of the relevant protection functions of the integrated type-specific components already is made in the factory.

  15. Investigation of critical frequencies of the centrifugal compressor rotor with taking into account stiffness of bearings and seals

    Directory of Open Access Journals (Sweden)

    I. V. Pavlenko

    2017-05-01

    Full Text Available In this paper the implementation of the mathematical model for rotor free oscillations of centrifugal machines is considered with the use of the computer program “Critical frequencies of the rotor”. The advantage of the program is the possibility of taking into account any advance given analytic dependence of support and seal stiffness on the rotor speed. As a result of numerical calculation on the example of the multistage centrifugal compressor 295GTS2-190/44-100M eigenfrequencies, critical frequencies and corresponding mode shapes are defined. The credibility of the proposed mathematical model is confirmed by theorem of the mutual position for spectrum of eigenfrequencies and correspondent critical frequencies, as well as by comparing the results of dynamic calculation in the program “Critical frequencies of the rotor” with the results of numerical simulation in ANSYS using the 3D finite element model and drawing the Campbell diagram.

  16. Combined Approach of PNN and Time-Frequency as the Classifier for Power System Transient Problems

    Directory of Open Access Journals (Sweden)

    Aslam Pervez Memon

    2013-04-01

    Full Text Available The transients in power system cause serious disturbances in the reliability, safety and economy of the system. The transient signals possess the nonstationary characteristics in which the frequency as well as varying time information is compulsory for the analysis. Hence, it is vital, first to detect and classify the type of transient fault and then to mitigate them. This article proposes time-frequency and FFNN (Feedforward Neural Network approach for the classification of power system transients problems. In this work it is suggested that all the major categories of transients are simulated, de-noised, and decomposed with DWT (Discrete Wavelet and MRA (Multiresolution Analysis algorithm and then distinctive features are extracted to get optimal vector as input for training of PNN (Probabilistic Neural Network classifier. The simulation results of proposed approach prove their simplicity, accurateness and effectiveness for the automatic detection and classification of PST (Power System Transient types

  17. Combined effects of 60Co dose and high frequency interferences on a discrete bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Raoult, J.; Jarrix, S.; Blain, A.; Dusseau, L.; Hoffmann, P.; Chatry, N.; Calvel, P.

    2012-01-01

    This paper concerns bipolar transistors subject to a double aggression: dose irradiation and high-frequency interference. The electromagnetic interference is injected in a contactless way in the near-field zone around the device. Parameters of the interference are power and frequency, the latter largely out of band of operation of the transistors. The output voltage of the transistor exhibits changes, due to rectification and to some extent to current crowding. The importance of the base bias set-up for the type of change occurring in voltage is displayed. After irradiation with a 60 Co source, the voltage output will change under electromagnetic interference but sometimes in an opposite way as initially measured. The impact of the irradiation with respect to electromagnetic susceptibility is highlighted from a physical point of view. Finally preliminary results of simulation for susceptibility prediction are given and a discussion is given on the limits of the transistor model used. (authors)

  18. Incorporating a multi-criteria decision procedure into the combined dynamic programming/production simulation algorithm for generation expansion planning

    International Nuclear Information System (INIS)

    Yang, H.T.; Chen, S.L.

    1989-01-01

    A multi-objective optimization approach to generation expansion planning is presented. The approach is designed by adding a new multi-criteria decision (MCD) procedure to the conventional algorithm which combines dynamic programming with production simulation method. The MCD procedure can help decision makers weight the relative importance of multiple attributes associated with the decision alternatives, and find the near-best compromise solution efficiently at each optimization step of the conventional algorithm. Practical application of proposed approach to feasibility evaluation of the fourth nuclear power plant of Tawian is also presented, demonstrating the effectiveness and limitations of the approach

  19. Swept-frequency feedback interferometry using terahertz frequency QCLs: a method for imaging and materials analysis.

    Science.gov (United States)

    Rakić, Aleksandar D; Taimre, Thomas; Bertling, Karl; Lim, Yah Leng; Dean, Paul; Indjin, Dragan; Ikonić, Zoran; Harrison, Paul; Valavanis, Alexander; Khanna, Suraj P; Lachab, Mohammad; Wilson, Stephen J; Linfield, Edmund H; Davies, A Giles

    2013-09-23

    The terahertz (THz) frequency quantum cascade laser (QCL) is a compact source of high-power radiation with a narrow intrinsic linewidth. As such, THz QCLs are extremely promising sources for applications including high-resolution spectroscopy, heterodyne detection, and coherent imaging. We exploit the remarkable phase-stability of THz QCLs to create a coherent swept-frequency delayed self-homodyning method for both imaging and materials analysis, using laser feedback interferometry. Using our scheme we obtain amplitude-like and phase-like images with minimal signal processing. We determine the physical relationship between the operating parameters of the laser under feedback and the complex refractive index of the target and demonstrate that this coherent detection method enables extraction of complex refractive indices with high accuracy. This establishes an ultimately compact and easy-to-implement THz imaging and materials analysis system, in which the local oscillator, mixer, and detector are all combined into a single laser.

  20. GLONASS orbit/clock combination in VNIIFTRI

    Science.gov (United States)

    Bezmenov, I.; Pasynok, S.

    2015-08-01

    An algorithm and a program for GLONASS satellites orbit/clock combination based on daily precise orbits submitted by several Analytic Centers were developed. Some theoretical estimates for combine orbit positions RMS were derived. It was shown that under condition that RMS of satellite orbits provided by the Analytic Centers during a long time interval are commensurable the RMS of combine orbit positions is no greater than RMS of other satellite positions estimated by any of the Analytic Centers.

  1. Frequency swept fibre laser for wind speed measurements

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier

    This PhD thesis builds around a light source forming the basis for a novel type of wind measuring lidar. The lidar emits a train of laser pulses with each pulse being separated from its neighbours in frequency, while being closely spaced in time, thus combining the advantages of conventional...... continuous wave (CW) and pulsed lidars. A light source capable of emitting such a pulse train is suggested. A theoretical description of all components constituting the light source is presented, and a time dependent model is developed and compared to measurements as well as to previous theoretical work from...... the scientific literature. The model presented shows good agreement with the experimental results regarding the pulse train envelope as well as the individual pulses. A model adopted from the literature is subsequently expanded to incorporate frequency components other than the main signal frequency and compared...

  2. Development of transient initiating event frequencies for use in probabilistic risk assessments

    International Nuclear Information System (INIS)

    Mackowiak, D.P.; Gentillon, C.D.; Smith, K.L.

    1985-05-01

    Transient initiating event frequencies are an essential input to the analysis process of a nuclear power plant probabilistic risk assessment. These frequencies describe events causing or requiring scrams. This report documents an effort to validate and update from other sources a computer-based data file developed by the Electric Power Research Institute (EPRI) describing such events at 52 United States commercial nuclear power plants. Operating information from the United States Nuclear Regulatory Commission on 24 additional plants from their date of commercial operation has been combined with the EPRI data, and the entire data base has been updated to add 1980 through 1983 events for all 76 plants. The validity of the EPRI data and data analysis methodology and the adequacy of the EPRI transient categories are examined. New transient initiating event frequencies are derived from the expanded data base using the EPRI transient categories and data display methods. Upper bounds for these frequencies are also provided. Additional analyses explore changes in the dominant transients, changes in transient outage times and their impact on plant operation, and the effects of power level and scheduled scrams on transient event frequencies. A more rigorous data analysis methodology is developed to encourage further refinement of the transient initiating event frequencies derived herein. Updating the transient event data base resulted in approx.2400 events being added to EPRI's approx.3000-event data file. The resulting frequency estimates were in most cases lower than those reported by EPRI, but no significant order-of-magnitude changes were noted. The average number of transients per year for the combined data base is 8.5 for pressurized water reactors and 7.4 for boiling water reactors

  3. Development of a novel fast frequency modulation scheme for the JET multi-channel reflectometer

    International Nuclear Information System (INIS)

    Deliyanakis, N.

    1999-10-01

    A novel frequency modulation scheme has been developed for the multi-channel reflectometer used to measure density profiles and density fluctuations on the JET tokamak. This reflectometer normally uses slow frequency sweeping, combined with fixed-frequency operation, to measure the group delay, as well as plasma fluctuations, at 10 different microwave frequencies. The novel scheme uses continuous frequency modulation on a time-scale much faster than that of plasma fluctuations, the main aim being to make the group delay measurement more robust against plasma fluctuations. This paper discusses the theoretical background of the scheme, gives a detailed description of the system, and presents results from plasma measurements. (author)

  4. Low frequency phase signal measurement with high frequency squeezing

    OpenAIRE

    Zhai, Zehui; Gao, Jiangrui

    2011-01-01

    We calculate the utility of high-frequency squeezed-state enhanced two-frequency interferometry for low-frequency phase measurement. To use the high-frequency sidebands of the squeezed light, a two-frequency intense laser is used in the interferometry instead of a single-frequency laser as usual. We find that the readout signal can be contaminated by the high-frequency phase vibration, but this is easy to check and avoid. A proof-of-principle experiment is in the reach of modern quantum optic...

  5. Seasonally adjusted birth frequencies follow the Poisson distribution.

    Science.gov (United States)

    Barra, Mathias; Lindstrøm, Jonas C; Adams, Samantha S; Augestad, Liv A

    2015-12-15

    Variations in birth frequencies have an impact on activity planning in maternity wards. Previous studies of this phenomenon have commonly included elective births. A Danish study of spontaneous births found that birth frequencies were well modelled by a Poisson process. Somewhat unexpectedly, there were also weekly variations in the frequency of spontaneous births. Another study claimed that birth frequencies follow the Benford distribution. Our objective was to test these results. We analysed 50,017 spontaneous births at Akershus University Hospital in the period 1999-2014. To investigate the Poisson distribution of these births, we plotted their variance over a sliding average. We specified various Poisson regression models, with the number of births on a given day as the outcome variable. The explanatory variables included various combinations of years, months, days of the week and the digit sum of the date. The relationship between the variance and the average fits well with an underlying Poisson process. A Benford distribution was disproved by a goodness-of-fit test (p Poisson process when monthly and day-of-the-week variation is included. The frequency is highest in summer towards June and July, Friday and Tuesday stand out as particularly busy days, and the activity level is at its lowest during weekends.

  6. Design and construction of an oscillator with a higly stable frequency

    International Nuclear Information System (INIS)

    Jardon, A.H.

    1978-01-01

    An instrument producing pulses with a highly stable frequency was considered necessary for time measurement at the INEN Plasma Physics Program. For this purpose an oscillator with a higly stable frequency which is a measurement instrument was designed and constructed since it can be used as a reference for the measurement of frequency, time, length and phase. The parameters required for this oscillator were as follows: aging lesser than 1 part/10 9 , for sampling period of 0.1 sec.; frequency change equal or smaller than 1 part/10 9 for normal temperature fluctuations found in the laboratory (10 0 C-30 0 C); frequency 1 MHz; amplitude 2 V. After the oscillator was built the parameters were not verified and therefore its characteristics are not exactly known; the reported partial results show that the approximations used for the design are generally valid. (author)

  7. Preface to Special Topic: Advances in Radio Frequency Physics in Fusion Plasmas

    International Nuclear Information System (INIS)

    Tuccillo, Angelo A.; Ceccuzzi, Silvio; Phillips, Cynthia K.

    2014-01-01

    It has long been recognized that auxiliary plasma heating will be required to achieve the high temperature, high density conditions within a magnetically confined plasma in which a fusion “burn” may be sustained by copious fusion reactions. Consequently, the application of radio and microwave frequency electromagnetic waves to magnetically confined plasma, commonly referred to as RF, has been a major part of the program almost since its inception in the 1950s. These RF waves provide heating, current drive, plasma profile control, and Magnetohydrodynamics (MHD) stabilization. Fusion experiments employ electromagnetic radiation in a wide range of frequencies, from tens of MHz to hundreds of GHz. The fusion devices containing the plasma are typically tori, axisymmetric or non, in which the equilibrium magnetic fields are composed of a strong toroidal magnetic field generated by external coils, and a poloidal field created, at least in the symmetric configurations, by currents flowing in the plasma. The waves are excited in the peripheral regions of the plasma, by specially designed launching structures, and subsequently propagate into the core regions, where resonant wave-plasma interactions produce localized heating or other modification of the local equilibrium profiles. Experimental studies coupled with the development of theoretical models and advanced simulation codes over the past 40+ years have led to an unprecedented understanding of the physics of RF heating and current drive in the core of magnetic fusion devices. Nevertheless, there are serious gaps in our knowledge base that continue to have a negative impact on the success of ongoing experiments and that must be resolved as the program progresses to the next generation devices and ultimately to “demo” and “fusion power plant.” A serious gap, at least in the ion cyclotron (IC) range of frequencies and partially in the lower hybrid frequency ranges, is the difficulty in coupling large amount of

  8. Preface to Special Topic: Advances in Radio Frequency Physics in Fusion Plasmas

    Science.gov (United States)

    Tuccillo, Angelo A.; Phillips, Cynthia K.; Ceccuzzi, Silvio

    2014-06-01

    It has long been recognized that auxiliary plasma heating will be required to achieve the high temperature, high density conditions within a magnetically confined plasma in which a fusion "burn" may be sustained by copious fusion reactions. Consequently, the application of radio and microwave frequency electromagnetic waves to magnetically confined plasma, commonly referred to as RF, has been a major part of the program almost since its inception in the 1950s. These RF waves provide heating, current drive, plasma profile control, and Magnetohydrodynamics (MHD) stabilization. Fusion experiments employ electromagnetic radiation in a wide range of frequencies, from tens of MHz to hundreds of GHz. The fusion devices containing the plasma are typically tori, axisymmetric or non, in which the equilibrium magnetic fields are composed of a strong toroidal magnetic field generated by external coils, and a poloidal field created, at least in the symmetric configurations, by currents flowing in the plasma. The waves are excited in the peripheral regions of the plasma, by specially designed launching structures, and subsequently propagate into the core regions, where resonant wave-plasma interactions produce localized heating or other modification of the local equilibrium profiles. Experimental studies coupled with the development of theoretical models and advanced simulation codes over the past 40+ years have led to an unprecedented understanding of the physics of RF heating and current drive in the core of magnetic fusion devices. Nevertheless, there are serious gaps in our knowledge base that continue to have a negative impact on the success of ongoing experiments and that must be resolved as the program progresses to the next generation devices and ultimately to "demo" and "fusion power plant." A serious gap, at least in the ion cyclotron (IC) range of frequencies and partially in the lower hybrid frequency ranges, is the difficulty in coupling large amount of power to the

  9. Frequency-Dependent Properties of Magnetic Nanoparticle Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Majetich, Sara [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2016-05-17

    In the proposed research program we will investigate the time- and frequency-dependent behavior of ordered nanoparticle assemblies, or nanoparticle crystals. Magnetostatic interactions are long-range and anisotropic, and this leads to complex behavior in nanoparticle assemblies, particularly in the time- and frequency-dependent properties. We hypothesize that the high frequency performance of composite materials has been limited because of the range of relaxation times; if a composite is a dipolar ferromagnet at a particular frequency, it should have the advantages of a single phase material, but without significant eddy current power losses. Arrays of surfactant-coated monodomain magnetic nanoparticles can exhibit long-range magnetic order that is stable over time. The magnetic domain size and location of domain walls is governed not by structural grain boundaries but by the shape of the array, due to the local interaction field. Pores or gaps within an assembly pin domain walls and limit the domain size. Measurements of the magnetic order parameter as a function of temperature showed that domains can exist at high temoerature, and that there is a collective phase transition, just as in an exchange-coupled ferromagnet. Dipolar ferromagnets are not merely of fundamental interest; they provide an interesting alternative to exchange-based ferromagnets. Dipolar ferromagnets made with high moment metallic particles in an insulating matrix could have high permeability without large eddy current losses. Such nanocomposites could someday replace the ferrites now used in phase shifters, isolators, circulators, and filters in microwave communications and radar applications. We will investigate the time- and frequency-dependent behavior of nanoparticle crystals with different magnetic core sizes and different interparticle barrier resistances, and will measure the magnetic and electrical properties in the DC, low frequency (0.1 Hz - 1 kHz), moderate frequency (10 Hz - 500

  10. Frequency Stability Enhancement for Low Inertia Systems using Synthetic Inertia of Wind Power

    DEFF Research Database (Denmark)

    Nguyen, Ha Thi; Yang, Guangya; Nielsen, Arne Hejde

    2017-01-01

    stability, this paper proposes supplementary control methods to implement synthetic inertia for doubly-fed induction generator (DFIG) based wind energy system during frequency excursions. Different control strategies and activation schemes are analyzed and implemented on the Western Danish renewable......-based system using-real time digital simulator (RTDS) to propose the best one for the synthetic inertia controller. From the comparative simulation results, it can be concluded that the method using a combination of both the frequency deviation and derivative as input signals, and the under-frequency trigger...

  11. Analysis of the analytic formulae application area for free oscillation frequency calculation in isochronous cyclotrons

    International Nuclear Information System (INIS)

    Kiyan, I.N.; Taraszkiewicz, R.

    2005-01-01

    Selection of optimal analytic formulae for calculation of free oscillation frequencies of the particles in isochronous cyclotrons, ν r (r) and ν z (r), and their application area are described. The selected formulae are used in the program BORP SR - Betatron Oscillation Research Program Second Release - written in C++ with the help of MS Visual C++ .NET. The free oscillation frequencies, calculated by using the program, are used for the evaluation of the modeled regimes of the work of the AIC144 isochronous cyclotron. The analytic formulae were selected by comparing the results of the calculations performed by using formulae adduced by T.Stammbach, Y.Jongen - S.Zaremba, V.V.Kolga with the results of the calculations performed by using the CYCLOPS iterative program, developed by M.M.Gordon. The least difference in the calculation results was obtained for the analytic formulae adduced by V.V.Kolga. The ν r (r) calculation difference ranged from -0.5 to 1.5% and the ν z (r) calculation difference ranged from -5 to 4% for the working radii of the isochronous cyclotron. As the beam was obtained, the selected analytic formulae can be successfully used in the program BORP SR for free oscillation frequency calculation during the evaluation of the modeled regimes of the work of different isochronous cyclotrons

  12. Destruction of Toluene by the Combination of High Frequency Discharge Electrodeless Lamp and Manganese Oxide-Impregnated Granular Activated Carbon Catalyst

    Directory of Open Access Journals (Sweden)

    Jianhui Xu

    2014-01-01

    Full Text Available The destruction of low concentration of toluene (0–30 ppm has been studied under the UV/photogenerated O3/MnO2-impregnated granular activated carbon (MnO2-impregnated GAC process by the combination of self-made high frequency discharge electrodeless lamp (HFDEL with MnO2-impregnated GAC catalyst. Experimental results showed that the initial toluene concentration can strongly affect the concentration of photogenerated O3 from HFDEL and the efficiency and mass rate of destruction of toluene via HFDEL/MnO2-impregnated GAC system. Active oxygen and hydroxyl radicals generated from HFDEL/MnO2-impregnated GAC system played a key role in the decomposition of toluene process and the intermediates formed by photolysis are more prone to be mineralized by the subsequent MnO2-impregnated GAC catalyst compared to the original toluene, resulting in synergistic mineralization of toluene by HFDEL/MnO2-impregnated GAC system. The role of MnO2-impregnated GAC catalyst is not only to eliminate the residual O3 completely but also to enhance the decomposition and mineralization of toluene.

  13. Accurate modeling of high frequency microelectromechanical systems (MEMS switches in time- and frequency-domainc

    Directory of Open Access Journals (Sweden)

    F. Coccetti

    2003-01-01

    Full Text Available In this contribution we present an accurate investigation of three different techniques for the modeling of complex planar circuits. The em analysis is performed by means of different electromagnetic full-wave solvers in the timedomain and in the frequency-domain. The first one is the Transmission Line Matrix (TLM method. In the second one the TLM method is combined with the Integral Equation (IE method. The latter is based on the Generalized Transverse Resonance Diffraction (GTRD. In order to test the methods we model different structures and compare the calculated Sparameters to measured results, with good agreement.

  14. Frequency tuning and directional sensitivity of tympanal vibrations in the field cricket Gryllus bimaculatus

    DEFF Research Database (Denmark)

    Lankheet, Martin J.; Cerkvenik, Uroš; Larsen, Ole Næsbye

    2017-01-01

    Female field crickets use phonotaxis to locate males by their calling song. Male song production and female behavioural sensitivity form a pair of matched frequency filters, which in Gryllus bimaculatus are tuned to a frequency of about 4.7 kHz. Directional sensitivity is supported by an elaborate...... play a major role in tuning directional sensitivity to the calling song frequency, by measuring tympanal vibrations as a function of sound direction and frequency. Rather than sharp frequency tuning of directional sensitivity corresponding to the calling song, we found broad frequency tuning......, with optima shifted to higher frequencies. These findings agree with predictions from a vector summation model for combining external and internal sounds. We show that the model provides robust directional sensitivity that is, however, broadly tuned with an optimum well above the calling song frequency. We...

  15. Triple-frequency GPS precise point positioning with rapid ambiguity resolution

    Science.gov (United States)

    Geng, Jianghui; Bock, Yehuda

    2013-05-01

    At present, reliable ambiguity resolution in real-time GPS precise point positioning (PPP) can only be achieved after an initial observation period of a few tens of minutes. In this study, we propose a method where the incoming triple-frequency GPS signals are exploited to enable rapid convergences to ambiguity-fixed solutions in real-time PPP. Specifically, extra-wide-lane ambiguity resolution can be first achieved almost instantaneously with the Melbourne-Wübbena combination observable on L2 and L5. Then the resultant unambiguous extra-wide-lane carrier-phase is combined with the wide-lane carrier-phase on L1 and L2 to form an ionosphere-free observable with a wavelength of about 3.4 m. Although the noise of this observable is around 100 times the raw carrier-phase noise, its wide-lane ambiguity can still be resolved very efficiently, and the resultant ambiguity-fixed observable can assist much better than pseudorange in speeding up succeeding narrow-lane ambiguity resolution. To validate this method, we use an advanced hardware simulator to generate triple-frequency signals and a high-grade receiver to collect 1-Hz data. When the carrier-phase precisions on L1, L2 and L5 are as poor as 1.5, 6.3 and 1.5 mm, respectively, wide-lane ambiguity resolution can still reach a correctness rate of over 99 % within 20 s. As a result, the correctness rate of narrow-lane ambiguity resolution achieves 99 % within 65 s, in contrast to only 64 % within 150 s in dual-frequency PPP. In addition, we also simulate a multipath-contaminated data set and introduce new ambiguities for all satellites every 120 s. We find that when multipath effects are strong, ambiguity-fixed solutions are achieved at 78 % of all epochs in triple-frequency PPP whilst almost no ambiguities are resolved in dual-frequency PPP. Therefore, we demonstrate that triple-frequency PPP has the potential to achieve ambiguity-fixed solutions within a few minutes, or even shorter if raw carrier-phase precisions are

  16. Using wavelets to decompose the time frequency effects of monetary policy

    Science.gov (United States)

    Aguiar-Conraria, Luís; Azevedo, Nuno; Soares, Maria Joana

    2008-05-01

    Central banks have different objectives in the short and long run. Governments operate simultaneously at different timescales. Many economic processes are the result of the actions of several agents, who have different term objectives. Therefore, a macroeconomic time series is a combination of components operating on different frequencies. Several questions about economic time series are connected to the understanding of the behavior of key variables at different frequencies over time, but this type of information is difficult to uncover using pure time-domain or pure frequency-domain methods. To our knowledge, for the first time in an economic setup, we use cross-wavelet tools to show that the relation between monetary policy variables and macroeconomic variables has changed and evolved with time. These changes are not homogeneous across the different frequencies.

  17. [Combined application of balneotherapy to the medical rehabilitation of patients with seronegative spondyloarthrites].

    Science.gov (United States)

    Barnatskiĭ, V V

    2008-01-01

    A rehabilitative complex combining radon baths and ultra-high frequency electromagnetic fields exerted a well-apparent beneficial effect on the clinical picture of articular and vertebral syndromes and greatly contributed to the correction of disturbances in the immune system of patients with seronegative spondyloarthritis. At the same time, combination of radon baths with low-frequency ultrasound treatment and hydrocortisone ultraphonophoresis reduced clinical activity of the disease, improved the patients' immune status, and had more prominent general anti-inflammatory action than the same physical factors applied as monotherapy.

  18. Frequency of aneuploidy related to age in porcine oocytes.

    Directory of Open Access Journals (Sweden)

    Miroslav Hornak

    Full Text Available It is generally accepted that mammalian oocytes are frequently suffering from chromosome segregation errors during meiosis I, which have severe consequences, including pregnancy loss, developmental disorders and mental retardation. In a search for physiologically more relevant model than rodent oocytes to study this phenomenon, we have employed comparative genomic hybridization (CGH, combined with whole genome amplification (WGA, to study the frequency of aneuploidy in porcine oocytes, including rare cells obtained from aged animals. Using this method, we were able to analyze segregation pattern of each individual chromosome during meiosis I. In contrast to the previous reports where conventional methods, such as chromosome spreads or FISH, were used to estimate frequency of aneuploidy, our results presented here show, that the frequency of this phenomenon was overestimated in porcine oocytes. Surprisingly, despite the results from human and mouse showing an increase in the frequency of aneuploidy with advanced maternal age, our results obtained by the most accurate method currently available for scoring the aneuploidy in oocytes indicated no increase in the frequency of aneuploidy even in oocytes from animals, whose age was close to the life expectancy of the breed.

  19. WOx cluster formation in radio frequency assisted pulsed laser deposition

    International Nuclear Information System (INIS)

    Filipescu, M.; Ossi, P.M.; Dinescu, M.

    2007-01-01

    The influence of oxygen gas pressure and radio-frequency power on the characteristics of the WO x films produced by laser ablation of a W target at room temperature in oxygen reactive atmosphere were investigated. Changing buffer gas pressure in the hundreds of Pa range affects the bond coordination, roughness and morphology of the deposited films, as investigated by micro-Raman spectroscopy, atomic force microscopy and scanning electron microscopy. The combination of radio-frequency discharge and buffer gas pressure on film nanostructure, as reflected by bond coordination, surface morphology and roughness is discussed

  20. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  1. Experimental demonstration of deep frequency modulation interferometry.

    Science.gov (United States)

    Isleif, Katharina-Sophie; Gerberding, Oliver; Schwarze, Thomas S; Mehmet, Moritz; Heinzel, Gerhard; Cervantes, Felipe Guzmán

    2016-01-25

    Experiments for space and ground-based gravitational wave detectors often require a large dynamic range interferometric position readout of test masses with 1 pm/√Hz precision over long time scales. Heterodyne interferometer schemes that achieve such precisions are available, but they require complex optical set-ups, limiting their scalability for multiple channels. This article presents the first experimental results on deep frequency modulation interferometry, a new technique that combines sinusoidal laser frequency modulation in unequal arm length interferometers with a non-linear fit algorithm. We have tested the technique in a Michelson and a Mach-Zehnder Interferometer topology, respectively, demonstrated continuous phase tracking of a moving mirror and achieved a performance equivalent to a displacement sensitivity of 250 pm/Hz at 1 mHz between the phase measurements of two photodetectors monitoring the same optical signal. By performing time series fitting of the extracted interference signals, we measured that the linearity of the laser frequency modulation is on the order of 2% for the laser source used.

  2. Influence of the Bolsa Família program on nutritional status and food frequency of schoolchildren

    Directory of Open Access Journals (Sweden)

    Ariene Silva do Carmo

    2016-07-01

    Full Text Available Objective: To evaluate the food frequency and nutritional status among students according to participation in the Bolsa Família program funded by the government. Methods: Cross-sectional study carried out with students from the fourth grade of elementary school in the municipal capital of the southeastern region of Brazil. Food consumption and anthropometry were investigated by a questionnaire administered in school, while participation in the Bolsa Família program and other socio-economic information was obtained through a protocol applied to mothers/guardians. Statistical analysis included the Mann–Whitney test, the chi-squared test, and Poisson regression with robust variance, and the 5% significance level was adopted. Results: There were 319 children evaluated; 56.4% were male, with a median of 9.4 (8.6–11.9 years, and 37.0% were beneficiaries of Bolsa Família program. Between the two groups, there was high prevalence of regular soda consumption (34.3%, artificial juice (49.5%, and sweets (40.3%, while only 54.3% and 51.7% consumed fruits and vegetables regularly, respectively. Among participants of Bolsa Família program, a prevalence 1.24 times higher in the regular consumption of soft drinks (95% CI: 1.10–1.39 was identified compared to non-beneficiaries. The prevalence of overweight was higher in the sample (32.9%, with no difference according to participation in the program. Conclusion: The study found increased consumption of soft drinks among BFP participants. The high rate of overweight and poor eating habits denote the need to develop actions to promote healthy eating, especially for the beneficiaries of the Bolsa Família program, to promote improvements in nutritional status and prevent chronic diseases throughout life. Resumo: Objetivo: Avaliar a frequência alimentar e estado nutricional entre escolares segundo a participação no programa governamental Bolsa Família (PBF. Metodologia: Estudo de delineamento

  3. Research on a Micro-Grid Frequency Modulation Strategy Based on Optimal Utilization of Air Conditioners

    Directory of Open Access Journals (Sweden)

    Qingzhu Wan

    2016-12-01

    Full Text Available With the proportion of air conditioners increasing gradually, they can provide a certain amount of frequency-controlled reserves for a micro-grid. Optimizing utilization of air conditioners and considering load response characteristics and customer comfort, the frequency adjustment model is a quadratic function model between the trigger temperature of the air conditioner compressor, and frequency variation is provided, which can be used to regulate the trigger temperature of the air conditioner when the micro-grid frequency rises and falls. This frequency adjustment model combines a primary frequency modulation method and a secondary frequency modulation method of the energy storage system, in order to optimize the frequency of a micro-grid. The simulation results show that the frequency modulation strategy for air conditioners can effectively improve the frequency modulation ability of air conditioners and frequency modulation effects of a micro-grid in coordination with an energy storage system.

  4. Passive radio frequency peak power multiplier

    Science.gov (United States)

    Farkas, Zoltan D.; Wilson, Perry B.

    1977-01-01

    Peak power multiplication of a radio frequency source by simultaneous charging of two high-Q resonant microwave cavities by applying the source output through a directional coupler to the cavities and then reversing the phase of the source power to the coupler, thereby permitting the power in the cavities to simultaneously discharge through the coupler to the load in combination with power from the source to apply a peak power to the load that is a multiplication of the source peak power.

  5. Derivatives of buckling loads and vibration frequencies with respect to stiffness and initial strain parameters

    Science.gov (United States)

    Haftka, Raphael T.; Cohen, Gerald A.; Mroz, Zenon

    1990-01-01

    A uniform variational approach to sensitivity analysis of vibration frequencies and bifurcation loads of nonlinear structures is developed. Two methods of calculating the sensitivities of bifurcation buckling loads and vibration frequencies of nonlinear structures, with respect to stiffness and initial strain parameters, are presented. A direct method requires calculation of derivatives of the prebuckling state with respect to these parameters. An adjoint method bypasses the need for these derivatives by using instead the strain field associated with the second-order postbuckling state. An operator notation is used and the derivation is based on the principle of virtual work. The derivative computations are easily implemented in structural analysis programs. This is demonstrated by examples using a general purpose, finite element program and a shell-of-revolution program.

  6. [Effects of therapeutic complexes including balneoradonokinesitherapy, electromyostimulation and low-frequency magnetotherapy on regional blood flow in patients with postrraumatic gonarthritis].

    Science.gov (United States)

    Raspopova, E A; Udartsev, E Iu

    2006-01-01

    Balneoradonokinesitherapy alone and its combination with electrostimulation and low-frequency magnetotherapy were used for the treatment of regional blood flow disorders in 76 patients with posttraumatic gonarthritis. Balneoradonokinesitherapy in combination with electromyostimulation improved blood circulation. When low-frequency magnetotherapy was added to the latter complex, the regress of regional blood flow disorders of a damaged extremity was most significant.

  7. Software for CATV Design and Frequency Plan Optimization

    OpenAIRE

    Hala, O.

    2007-01-01

    The paper deals with the structure of a software medium used for design and sub-optimization of frequency plan in CATV networks, their description and design method. The software performance is described and a simple design example of energy balance of a simplified CATV network is given. The software was created in programming environment called Delphi and local optimization was made in Matlab.

  8. Influence of modulation frequency in rubidium cell frequency standards

    Science.gov (United States)

    Audoin, C.; Viennet, J.; Cyr, N.; Vanier, J.

    1983-01-01

    The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

  9. Three-Dimensional Dynamic Topology Optimization with Frequency Constraints Using Composite Exponential Function and ICM Method

    Directory of Open Access Journals (Sweden)

    Hongling Ye

    2015-01-01

    Full Text Available The dynamic topology optimization of three-dimensional continuum structures subject to frequency constraints is investigated using Independent Continuous Mapping (ICM design variable fields. The composite exponential function (CEF is selected to be a filter function which recognizes the design variables and to implement the changing process of design variables from “discrete” to “continuous” and back to “discrete.” Explicit formulations of frequency constraints are given based on filter functions, first-order Taylor series expansion. And an improved optimal model is formulated using CEF and the explicit frequency constraints. Dual sequential quadratic programming (DSQP algorithm is used to solve the optimal model. The program is developed on the platform of MSC Patran & Nastran. Finally, numerical examples are given to demonstrate the validity and applicability of the proposed method.

  10. Graphene screen-printed radio-frequency identification devices on flexible substrates

    NARCIS (Netherlands)

    Arapov, K.; Jaakkola, K.; Ermolov, V.; Bex, G.; Rubingh, E.; Haque, S.; Sandberg, H.; Abbel, R.; de With, G.; Friedrich, H.

    2016-01-01

    Despite the great promise of printed flexible electronics from 2D crystals, and especially graphene, few scalable applications have been reported so far that can be termed roll-to-roll compatible. Here we combine screen printed graphene with photonic annealing to realize radio-frequency

  11. Ultra-Wideband Printed Slot Radiators with Controllable Frequency Characteristics

    Directory of Open Access Journals (Sweden)

    S. L. Chernyshev

    2015-01-01

    Full Text Available We have studied the possibility of creating ultra-wideband (UWB antennas with controlled frequency response of matching based on the printed slot antenna Vivaldi by introducing controlled resonators directly into the structure of the radiator. In the area of irregular slotline there are printed switched resonators with variable capacitance (varactor model, which allow tuning the frequency characteristics for each state of switching cavities, providing bandpass and band-barrage properties of the antenna. The investigation of reconfigurable printed resonators in the system of reconfigurable resonators of a bandpass filter is conducted. The paper considers filter to provide restructuring in the band (3-9 GHz. Electrodynamic simulation of the device was carried out in the time domain using a finite integration method. A bandstop reconfigurable filter is also investigated. The filter located on the substrate opposite the slit is based on tunable L-shaped resonator that has one end connected to the short-circuitor through the board metallization; the other end remains open and is brought into the region of interaction with the slotline. Such filter provides an effective narrow-band suppression and can be easily tuned to the desired frequency channel. The combination of these two types of filters allows you to create a controlled print Vivaldi slot antenna with combined properties. The paper investigates parameters of the scattering and radiation pattern of the antenna in different modes.

  12. Radio frequency-assisted fast superconducting switch

    Science.gov (United States)

    Solovyov, Vyacheslav; Li, Qiang

    2017-12-05

    A radio frequency-assisted fast superconducting switch is described. A superconductor is closely coupled to a radio frequency (RF) coil. To turn the switch "off," i.e., to induce a transition to the normal, resistive state in the superconductor, a voltage burst is applied to the RF coil. This voltage burst is sufficient to induce a current in the coupled superconductor. The combination of the induced current with any other direct current flowing through the superconductor is sufficient to exceed the critical current of the superconductor at the operating temperature, inducing a transition to the normal, resistive state. A by-pass MOSFET may be configured in parallel with the superconductor to act as a current shunt, allowing the voltage across the superconductor to drop below a certain value, at which time the superconductor undergoes a transition to the superconducting state and the switch is reset.

  13. The combined effects of MRI and X-radiation on ICR mouse embryos during organogenesis

    International Nuclear Information System (INIS)

    Gu, Y.H.; Hasegawa, T.; Yamamoto, Y.; Mori, T.; Bamen, K.; Iwasa, T.; Kai, M.; Kusama, T.

    2000-01-01

    The combined effects of X-radiation magnetic resonance imaging (MRI) malformations, fetal body weight and sex ratios of mice treated on day 8 of gestation were determined at day 18 of gestation. These were no significant differences in the frequency of prenatal death, fetal body weight and sex ratios between control and 0.5 T irradiated mice. The frequencies of embryonic deaths in mice irradiated with X-rays increased significantly. The frequencies of external malformations such as exencephaly and anophthalmia in mice irradiated with X-rays or MRI increased significantly. However the frequencies of external malformation and prenatal death in the mice irradiated with both X-rays and MRI decreased more than in mice irradiated with X-rays alone. The combined effects of radiation and MRI on the external malformations and embryonic death might be antagonistic. (author)

  14. The combined effects of MRI and X-radiation on ICR mouse embryos during organogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Y.H.; Hasegawa, T.; Yamamoto, Y.; Mori, T. [Suzuka University of Medical Science, Department of Radiological Technology, Suzuka, Mie (Japan); Bamen, K.; Iwasa, T. [Oita University of Nursing and Health Sciences, Department of Health Science, Oita (Japan); Kai, M.; Kusama, T. [Bio Queen Co., Ltd., Tokyo (Japan)

    2000-05-01

    The combined effects of X-radiation magnetic resonance imaging (MRI) malformations, fetal body weight and sex ratios of mice treated on day 8 of gestation were determined at day 18 of gestation. These were no significant differences in the frequency of prenatal death, fetal body weight and sex ratios between control and 0.5 T irradiated mice. The frequencies of embryonic deaths in mice irradiated with X-rays increased significantly. The frequencies of external malformations such as exencephaly and anophthalmia in mice irradiated with X-rays or MRI increased significantly. However the frequencies of external malformation and prenatal death in the mice irradiated with both X-rays and MRI decreased more than in mice irradiated with X-rays alone. The combined effects of radiation and MRI on the external malformations and embryonic death might be antagonistic. (author)

  15. Passive ultra high frequency radio frequency identification systems for single-item identification in food supply chains

    Directory of Open Access Journals (Sweden)

    Paolo Barge

    2017-02-01

    Full Text Available In the food industry, composition, size, and shape of items are much less regular than in other commodities sectors. In addition, a wide variety of packaging, composed by different materials, is employed. As material, size and shape of items to which the tag should be attached strongly influence the minimum power requested for tag functioning, performance improvements can be achieved only selecting suitable radio frequency (RF identifiers for the specific combination of food product and packaging. When dealing with logistics units, the dynamic reading of a vast number of tags could originate simultaneous broadcasting of signals (tag-to-tag collisions that could affect reading rates and the overall reliability of the identification procedure. This paper reports the results of an analysis of the reading performance of ultra high frequency radio frequency identification systems for multiple static and dynamic electronic identification of food packed products in controlled conditions. Products were considered when arranged on a logistics pallet. The effects on reading rate of different factors, among which the product type, the gate configuration, the field polarisation, the power output of the RF reader, the interrogation protocol configuration as well as the transit speed, the number of tags and their interactions were statistically analysed and compared.

  16. Syllable Frequency and Syllable Structure in Apraxia of Speech

    Science.gov (United States)

    Aichert, Ingrid; Ziegler, Wolfram

    2004-01-01

    Recent accounts of the pathomechanism underlying apraxia of speech (AOS) were based on the speech production model of Levelt, Roelofs, and Meyer, and Meyer (1999)1999. The apraxic impairment was localized to the phonetic encoding level where the model postulates a mental store of motor programs for high-frequency syllables. Varley and Whiteside…

  17. High Frequency Amplitude Detector for GMI Magnetic Sensors

    Directory of Open Access Journals (Sweden)

    Aktham Asfour

    2014-12-01

    Full Text Available A new concept of a high-frequency amplitude detector and demodulator for Giant-Magneto-Impedance (GMI sensors is presented. This concept combines a half wave rectifier, with outstanding capabilities and high speed, and a feedback approach that ensures the amplitude detection with easily adjustable gain. The developed detector is capable of measuring high-frequency and very low amplitude signals without the use of diode-based active rectifiers or analog multipliers. The performances of this detector are addressed throughout the paper. The full circuitry of the design is given, together with a comprehensive theoretical study of the concept and experimental validation. The detector has been used for the amplitude measurement of both single frequency and pulsed signals and for the demodulation of amplitude-modulated signals. It has also been successfully integrated in a GMI sensor prototype. Magnetic field and electrical current measurements in open- and closed-loop of this sensor have also been conducted.

  18. Very High Frequency Galvanic Isolated Offline Power Supply

    DEFF Research Database (Denmark)

    Pedersen, Jeppe Arnsdorf

    During the last decades many researchers have turned their attention to raising the operation frequency of power converters to the very high frequency (VHF) range going from 30 MHz to 300 MHz. Increasing the operating frequency of a power converter leads to smaller energy storing components...... inverters with a single combined rectifier. The converter designed to deliver 9 W to a 60 V LED load and is achieving an efficiency of 89.4% and a power density of 2.14 W3 . The development of this converter proof that offline VHF converter can be implemented with high efficiencies even for low power applications...... are described together with the possibility of using capacitors as the power galvanic isolation, both methods of creating galvanic isolation are implemented in converters. Regarding EMC a series of converters with different filter implementations are examined. The results from the conducted mea-surement from 150...

  19. Possible Explanation for Cancer in Rats due to Cell Phone Radio Frequency Radiation

    Science.gov (United States)

    Feldman, Bernard J.

    Very recently, the National Toxicology Program reported a correlation between exposure to whole body 900 MHz radio frequency radiation and cancer in the brains and hearts of Sprague Dawley male rats. Assuming that the National Toxicology Program is statistically significant, I propose the following explanation for these results. The neurons around the brain and heart form closed electrical circuits and, following Faraday's Law, 900 MHz radio frequency radiation induces 900 MHz electrical currents in these neural circuits. In turn, these 900 MHz currents in the neural circuits generate sufficient localized heat in the neural cells to shift the equilibrium concentration of carcinogenic radicals to higher levels and thus, to higher incidences of cancer.

  20. Frequency Equations for the In-Plane Vibration of Circular Annular Disks

    Directory of Open Access Journals (Sweden)

    S. Bashmal

    2010-01-01

    Full Text Available This paper deals with the in-plane vibration of circular annular disks under combinations of different boundary conditions at the inner and outer edges. The in-plane free vibration of an elastic and isotropic disk is studied on the basis of the two-dimensional linear plane stress theory of elasticity. The exact solution of the in-plane equation of equilibrium of annular disk is attainable, in terms of Bessel functions, for uniform boundary conditions. The frequency equations for different modes can be obtained from the general solutions by applying the appropriate boundary conditions at the inner and outer edges. The presented frequency equations provide the frequency parameters for the required number of modes for a wide range of radius ratios and Poisson's ratios of annular disks under clamped, free, or flexible boundary conditions. Simplified forms of frequency equations are presented for solid disks and axisymmetric modes of annular disks. Frequency parameters are computed and compared with those available in literature. The frequency equations can be used as a reference to assess the accuracy of approximate methods.

  1. First-principles studies of PETN molecular crystal vibrational frequencies under high pressure

    Science.gov (United States)

    Perger, Warren; Zhao, Jijun

    2005-07-01

    The vibrational frequencies of the PETN molecular crystal were calculated using the first-principles CRYSTAL03 program which employs an all-electron LCAO approach and calculates analytic first derivatives of the total energy with respect to atomic displacements. Numerical second derivatives were used to enable calculation of the vibrational frequencies at ambient pressure and under various states of compression. Three different density functionals, B3LYP, PW91, and X3LYP were used to examine the effect of the exchange-correlation functional on the vibrational frequencies. The pressure-induced shift of the vibrational frequencies will be presented and compared with experiment. The average deviation with experimental results is shown to be on the order of 2-3%, depending on the functional used.

  2. Ares I-X Flight Test Validation of Control Design Tools in the Frequency-Domain

    Science.gov (United States)

    Johnson, Matthew; Hannan, Mike; Brandon, Jay; Derry, Stephen

    2011-01-01

    A major motivation of the Ares I-X flight test program was to Design for Data, in order to maximize the usefulness of the data recorded in support of Ares I modeling and validation of design and analysis tools. The Design for Data effort was intended to enable good post-flight characterizations of the flight control system, the vehicle structural dynamics, and also the aerodynamic characteristics of the vehicle. To extract the necessary data from the system during flight, a set of small predetermined Programmed Test Inputs (PTIs) was injected directly into the TVC signal. These PTIs were designed to excite the necessary vehicle dynamics while exhibiting a minimal impact on loads. The method is similar to common approaches in aircraft flight test programs, but with unique launch vehicle challenges due to rapidly changing states, short duration of flight, a tight flight envelope, and an inability to repeat any test. This paper documents the validation effort of the stability analysis tools to the flight data which was performed by comparing the post-flight calculated frequency response of the vehicle to the frequency response calculated by the stability analysis tools used to design and analyze the preflight models during the control design effort. The comparison between flight day frequency response and stability tool analysis for flight of the simulated vehicle shows good agreement and provides a high level of confidence in the stability analysis tools for use in any future program. This is true for both a nominal model as well as for dispersed analysis, which shows that the flight day frequency response is enveloped by the vehicle s preflight uncertainty models.

  3. Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors.

    Science.gov (United States)

    Stierstorfer, Karl

    2018-01-01

    To find a simple model for the frequency-dependent detective quantum efficiency (DQE) of photon-counting detectors in the low flux limit. Formula for the spatial cross-talk, the noise power spectrum and the DQE of a photon-counting detector working at a given threshold are derived. Parameters are probabilities for types of events like single counts in the central pixel, double counts in the central pixel and a neighboring pixel or single count in a neighboring pixel only. These probabilities can be derived in a simple model by extensive use of Monte Carlo techniques: The Monte Carlo x-ray propagation program MOCASSIM is used to simulate the energy deposition from the x-rays in the detector material. A simple charge cloud model using Gaussian clouds of fixed width is used for the propagation of the electric charge generated by the primary interactions. Both stages are combined in a Monte Carlo simulation randomizing the location of impact which finally produces the required probabilities. The parameters of the charge cloud model are fitted to the spectral response to a polychromatic spectrum measured with our prototype detector. Based on the Monte Carlo model, the DQE of photon-counting detectors as a function of spatial frequency is calculated for various pixel sizes, photon energies, and thresholds. The frequency-dependent DQE of a photon-counting detector in the low flux limit can be described with an equation containing only a small set of probabilities as input. Estimates for the probabilities can be derived from a simple model of the detector physics. © 2017 American Association of Physicists in Medicine.

  4. A program for dynamic noise investigations of reactor systems

    International Nuclear Information System (INIS)

    Antonov, N.A.; Yaneva, N.B.

    1980-01-01

    A stochastic process analysis in nuclear reactors is used for the state diagnosis and dynamic characteristic investigation of the reactor system. A program DENSITY adapted and tested on an IBM 360 ES type computer is developed. The program is adjusted for fast processing of long series exploiting a relatively small memory. The testing procedure is discussed and the method of the periodic sequences corresponding to characteristic reactivity perturbations of the reactor systems is considered. The program is written for calculating the auto-power spectral density and the cross-power spectral density, as well as the coherence function of stationary statistical time series using the advantages of the fast Fourier transformation. In particular, it is shown that the multi-frequency binary sequences are very useful with respect to the signal-to-noise ratio and the frequency distribution in view of the frequency reactor test

  5. NEK AOV program

    International Nuclear Information System (INIS)

    Fable, D.; Andric, A.; Prah, M.; Habinc, M.

    2002-01-01

    Air Operated Valves (AOVs) are used in a wide variety of applications in nuclear power plants. Some AOVs perform important functions in safety and non-safety related systems which could affect initiating event frequencies, accident mitigation and radiological releases. A review of lessons learned from nuclear plant MOV programs and pilot AOV programs indicates that AOV performance can be enhanced via improvements in valve and actuator sizing, setup, testing and maintenance. Nuklearna elektrarna Krsko has decided to develop an AOV program on the basis of Joint Owners. Group (JOG) AOV Program, which identifies nine key elements for successful implementation. The first step in establishing an AOV Program is to identify and categorize the plant AOVs for evaluation. Performed categorization in NEK has resulted with Preliminary AOV Scope. Important part of NEK AOV Program is NEK AOV Database. For the time being, basic structure with tables, queries, forms, reports and relationships has been created. Further development will be coordinated with development of NEK AOV Program Methodology.(author)

  6. The Trailblazer Program

    Science.gov (United States)

    Trefney, Charles J.

    1999-01-01

    This paper presents the "Three Pillars of Success" for the Trailblazer Program. The topics include: 1) The "Rocket Equation" for SSTO (Single Stage To Orbit); 2) The Rocket I* Barrier; 3) Rocket-Based Combined-Cycle Engine; 4) Potential for Reusability; 5) Factors Mitigating RBCC Performance; 6) The "Trailblazer" Program; 7) Trailblazer Performance Goals; 8) Trailblazer Reference Vehicle; and 9) Trailblazer Program Architecture.

  7. The low-frequency encoding disadvantage: Word frequency affects processing demands.

    Science.gov (United States)

    Diana, Rachel A; Reder, Lynne M

    2006-07-01

    Low-frequency words produce more hits and fewer false alarms than high-frequency words in a recognition task. The low-frequency hit rate advantage has sometimes been attributed to processes that operate during the recognition test (e.g., L. M. Reder et al., 2000). When tasks other than recognition, such as recall, cued recall, or associative recognition, are used, the effects seem to contradict a low-frequency advantage in memory. Four experiments are presented to support the claim that in addition to the advantage of low-frequency words at retrieval, there is a low-frequency disadvantage during encoding. That is, low-frequency words require more processing resources to be encoded episodically than high-frequency words. Under encoding conditions in which processing resources are limited, low-frequency words show a larger decrement in recognition than high-frequency words. Also, studying items (pictures and words of varying frequencies) along with low-frequency words reduces performance for those stimuli. Copyright 2006 APA, all rights reserved.

  8. Development of transient initiating event frequencies for use in probabilistic risk assessments

    Energy Technology Data Exchange (ETDEWEB)

    Mackowiak, D.P.; Gentillon, C.D.; Smith, K.L.

    1985-05-01

    Transient initiating event frequencies are an essential input to the analysis process of a nuclear power plant probabilistic risk assessment. These frequencies describe events causing or requiring scrams. This report documents an effort to validate and update from other sources a computer-based data file developed by the Electric Power Research Institute (EPRI) describing such events at 52 United States commercial nuclear power plants. Operating information from the United States Nuclear Regulatory Commission on 24 additional plants from their date of commercial operation has been combined with the EPRI data, and the entire data base has been updated to add 1980 through 1983 events for all 76 plants. The validity of the EPRI data and data analysis methodology and the adequacy of the EPRI transient categories are examined. New transient initiating event frequencies are derived from the expanded data base using the EPRI transient categories and data display methods. Upper bounds for these frequencies are also provided. Additional analyses explore changes in the dominant transients, changes in transient outage times and their impact on plant operation, and the effects of power level and scheduled scrams on transient event frequencies. A more rigorous data analysis methodology is developed to encourage further refinement of the transient initiating event frequencies derived herein. Updating the transient event data base resulted in approx.2400 events being added to EPRI's approx.3000-event data file. The resulting frequency estimates were in most cases lower than those reported by EPRI, but no significant order-of-magnitude changes were noted. The average number of transients per year for the combined data base is 8.5 for pressurized water reactors and 7.4 for boiling water reactors.

  9. Frequency variations of gravity waves interacting with a time-varying tide

    Energy Technology Data Exchange (ETDEWEB)

    Huang, C.M.; Zhang, S.D.; Yi, F.; Huang, K.M.; Gan, Q.; Gong, Y. [Wuhan Univ., Hubei (China). School of Electronic Information; Ministry of Education, Wuhan, Hubei (China). Key Lab. of Geospace Environment and Geodesy; State Observatory for Atmospheric Remote Sensing, Wuhan, Hubei (China); Zhang, Y.H. [Nanjing Univ. of Information Science and Technology (China). College of Hydrometeorolgy

    2013-11-01

    Using a nonlinear, 2-D time-dependent numerical model, we simulate the propagation of gravity waves (GWs) in a time-varying tide. Our simulations show that when aGW packet propagates in a time-varying tidal-wind environment, not only its intrinsic frequency but also its ground-based frequency would change significantly. The tidal horizontal-wind acceleration dominates the GW frequency variation. Positive (negative) accelerations induce frequency increases (decreases) with time. More interestingly, tidal-wind acceleration near the critical layers always causes the GW frequency to increase, which may partially explain the observations that high-frequency GW components are more dominant in the middle and upper atmosphere than in the lower atmosphere. The combination of the increased ground-based frequency of propagating GWs in a time-varying tidal-wind field and the transient nature of the critical layer induced by a time-varying tidal zonal wind creates favorable conditions for GWs to penetrate their originally expected critical layers. Consequently, GWs have an impact on the background atmosphere at much higher altitudes than expected, which indicates that the dynamical effects of tidal-GW interactions are more complicated than usually taken into account by GW parameterizations in global models.

  10. Effectiveness of the Vital Aging program to promote active aging in Mexican older adults

    Directory of Open Access Journals (Sweden)

    Mendoza-Ruvalcaba NM

    2016-11-01

    Full Text Available Neyda Ma Mendoza-Ruvalcaba,1 Rocío Fernández-Ballesteros2 1Health Sciences Department, University of Guadalajara, University Center of Tonalá, Tonalá, Jalisco, Mexico; 2Department of Biological and Health Psychology, Autonomous University of Madrid, Madrid, Spain Introduction: Aging is not only a population phenomenon but also an experience and an individual reality. Vital Aging® is a program that considers active aging as the lifelong adaptation process of maximizing health and independence, physical and cognitive functioning, positive affect regulation and control, and social engagement. Through its different versions and editions, it has demonstrated being an effective program to promote active aging. The aim of this study is to determine the effectiveness of the “face-to-face” and “combined” versions of the program to promote active aging in Mexican older adults trial. Methods: Seventy-six older adults aged 60 years and over participated in a quasi-experimental study and were recruited in a senior center to participate in the two experimental conditions: Vital Aging face-to-face (VA-FF (n=35 and Vital Aging combined (VA-C; multimedia/face-to-face (n=15, and the remaining 26 adults were assigned to a control group. Pretest and posttest assessments were performed after the theoretical–practical intervention. Mean differences and size effects were calculated for estimating the effect of the program. Results: At the end of the study, participants showed improvements in the active aging outcome measures. Positive effects were observed in the frequency of intellectual, cultural – artistic, and social activities, perceptions of aging, satisfaction with social relationships, and self-efficacy for aging. Additionally, those who participated in VA-FF showed better memory performance, meta-memory, and a trend to report less memory problems, while older persons in VA-C showed a trend to have better life satisfaction. No effects were

  11. An efficient hybrid technique in RCS predictions of complex targets at high frequencies

    Science.gov (United States)

    Algar, María-Jesús; Lozano, Lorena; Moreno, Javier; González, Iván; Cátedra, Felipe

    2017-09-01

    Most computer codes in Radar Cross Section (RCS) prediction use Physical Optics (PO) and Physical theory of Diffraction (PTD) combined with Geometrical Optics (GO) and Geometrical Theory of Diffraction (GTD). The latter approaches are computationally cheaper and much more accurate for curved surfaces, but not applicable for the computation of the RCS of all surfaces of a complex object due to the presence of caustic problems in the analysis of concave surfaces or flat surfaces in the far field. The main contribution of this paper is the development of a hybrid method based on a new combination of two asymptotic techniques: GTD and PO, considering the advantages and avoiding the disadvantages of each of them. A very efficient and accurate method to analyze the RCS of complex structures at high frequencies is obtained with the new combination. The proposed new method has been validated comparing RCS results obtained for some simple cases using the proposed approach and RCS using the rigorous technique of Method of Moments (MoM). Some complex cases have been examined at high frequencies contrasting the results with PO. This study shows the accuracy and the efficiency of the hybrid method and its suitability for the computation of the RCS at really large and complex targets at high frequencies.

  12. Multi-frequency response of a cylinder subjected to vortex shedding and support motions

    Energy Technology Data Exchange (ETDEWEB)

    Vikestad, Kyrre

    1998-12-31

    This thesis deals with an experimental investigation of vortex induced vibrations of a circular cylinder. The purpose of the experiment was to identify the influence from a controlled disturbance of the cylinder motions on the response caused by vortex shedding. The cylinder investigated is 2 m long and the diameter is 10 cm. The cylinder is elastically mounted in an apparatus using springs, where the foundation of one of the springs can have a harmonic motion. The apparatus is placed on a carriage in a 25 m long towing tank. Towing velocities are varied between 0.140 m/s and 0.655 m/s corresponding to reduced velocity range from 2.8 to 13.2. The still water natural frequency is 0.497 Hz, and the natural frequency in air is 0.634 Hz. The cylinder is only able to oscillate in the cross-flow direction. The support motion frequency was varied between 0.26 Hz and 1.01 Hz, and the force motion amplitude was varied using 2, 4 and 6 cm support amplitudes. Three sets of experiments were carried out: (1) Still water oscillations due to harmonic support motion excitation, support amplitude and frequencies varied, (2) Towing tests with no support motion, the velocity is varied, (3) Combined excitation: Towing tests with support motion. All possible combinations of experiments (1) and (2) are carried out. The two first experiments provide reference values for the combined excitation experiments and for verification purposes. The results reveal the ability of the external disturbance to influence the vortex shedding process both regarding frequency and the resulting response amplitudes. Results for added mass, in-line drag and damping are also obtained. The work may be of use in deep water floating petroleum production. 81 refs., 73 figs., 6 tabs.

  13. [Modulating effect of weak combined magnetic fields on duration of mealworm beetle Tenebrio molitor metamorphosis stage].

    Science.gov (United States)

    Novikov, V V; Sheĭman, I M; Iablokova, E V; Fesenko, E E

    2014-01-01

    It is shown that an exposure of pupae of the mealworm beetle Tenebrio molitor to the combined static (42 μT) and very weak alternating (250 nT) magnetic fields exerts different influence, depending on the frequency of the alternating magnetic field, on duration of metamorphosis processes in these insects. For instance, an exposure of pupae to weak combined magnetic fields, adjusted to the frequency of ion cyclotron resonance for glutaminic acid (4,4 Hz), stimulates metamorphosis process--a transitional stage from pupae to imago lasts shorter. An inhibiting effect was observed when adjusted to the frequency of ion cyclotron resonance for Ca2 (32,2 Hz). At some frequencies this effect is not seen. For instance, an exposure at a frequency of ion cyclotron resonance for K+ (16,5 Hz) exerts no noticeable effect on the duration of the pupal metamorphosis stage.

  14. Pre-Learning Low-Frequency Vocabulary in Second Language Television Programmes

    Science.gov (United States)

    Webb, Stuart

    2010-01-01

    This study investigated the potential of pre-learning frequently occurring low-frequency vocabulary as a means to increase comprehension of television and incidental vocabulary learning through watching television. Eight television programmes, each representing different television genres, were analysed using the RANGE program to determine the 10…

  15. The analysis of cable forces based on natural frequency

    Science.gov (United States)

    Suangga, Made; Hidayat, Irpan; Juliastuti; Bontan, Darwin Julius

    2017-12-01

    A cable is a flexible structural member that is effective at resisting tensile forces. Cables are used in a variety of structures that employ their unique characteristics to create efficient design tension members. The condition of the cable forces in the cable supported structure is an important indication of judging whether the structure is in good condition. Several methods have been developed to measure on site cable forces. Vibration technique using correlation between natural frequency and cable forces is a simple method to determine in situ cable forces, however the method need accurate information on the boundary condition, cable mass, and cable length. The natural frequency of the cable is determined using FFT (Fast Fourier Transform) Technique to the acceleration record of the cable. Based on the natural frequency obtained, the cable forces then can be determine by analytical or by finite element program. This research is focus on the vibration techniques to determine the cable forces, to understand the physical parameter effect of the cable and also modelling techniques to the natural frequency and cable forces.

  16. Numerical investigations of single bubble oscillations generated by a dual frequency excitation

    International Nuclear Information System (INIS)

    Guédra, Matthieu; Inserra, Claude; Gilles, Bruno; Béra, Jean-Christophe

    2015-01-01

    The oscillations of a single bubble excited with a dual frequency acoustic field are numerically investigated. Computations are made for an air bubble in water exposed to an acoustic field with a linearly varying amplitude. The bubble response to an excitation containing two frequencies f 1 = 500 kHz and f 2 = 400 kHz at the same amplitude is compared to the monofrequency case where only f 1 is present. Time-frequency representations show a sharp transition in the bifrequency case, for which the low frequency component f 2 becomes resonant while the high frequency component f 1 is strongly attenuated. The temporal evolution of the power spectra reveals that the resonance of the low frequency component is correlated with the time varying mean radius of the bubble. It is also observed that the total power of the bubble response in the bifrequency case can reach almost twice the power obtained in the monofrequency case, which indicates a strong enhancement of the cavitating behavior of the bubble for this specific frequency combination. (paper)

  17. Frequency Fine-tuning of a Spin-flip Cavity for Antihydrogen Atoms

    CERN Document Server

    Federmann, S; Mahner, E; Juhasz, B; Widmann, E

    2012-01-01

    As part of the ASACUSA (Atomic Spectroscopy And Collisions Using Slow Antiprotons) physics program a spin-flip cavity, for measurements of the ground-state hyperfine transition frequency of antihydrogen atoms, is needed. The purpose of the cavity is to excite antihydrogen atoms depending on their polarisation by a microwave field operating at 1.42 GHz. The delicacy of designing such a cavity lies in achieving and maintaining the required properties of this field over a large aperture of 10 cm and for a long period of time (required amplitude stability is 1% over 12 h). This paper presents the frequency fine tuning techniques developed to obtain the desired centre frequency of 1.42GHz with a Q value below 500 as well as the circuit used for the frequency sweep over a bandwidth of 6MHz.

  18. Frequency-dependent Dispersion Measures and Implications for Pulsar Timing

    Science.gov (United States)

    Cordes, J. M.; Shannon, R. M.; Stinebring, D. R.

    2016-01-01

    The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency2). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ˜ 4 × 10-5 pc cm-3 for pulsars at ˜1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm-3 but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

  19. Time-variant random interval natural frequency analysis of structures

    Science.gov (United States)

    Wu, Binhua; Wu, Di; Gao, Wei; Song, Chongmin

    2018-02-01

    This paper presents a new robust method namely, unified interval Chebyshev-based random perturbation method, to tackle hybrid random interval structural natural frequency problem. In the proposed approach, random perturbation method is implemented to furnish the statistical features (i.e., mean and standard deviation) and Chebyshev surrogate model strategy is incorporated to formulate the statistical information of natural frequency with regards to the interval inputs. The comprehensive analysis framework combines the superiority of both methods in a way that computational cost is dramatically reduced. This presented method is thus capable of investigating the day-to-day based time-variant natural frequency of structures accurately and efficiently under concrete intrinsic creep effect with probabilistic and interval uncertain variables. The extreme bounds of the mean and standard deviation of natural frequency are captured through the embedded optimization strategy within the analysis procedure. Three particularly motivated numerical examples with progressive relationship in perspective of both structure type and uncertainty variables are demonstrated to justify the computational applicability, accuracy and efficiency of the proposed method.

  20. Considering genetic characteristics in German Holstein breeding programs.

    Science.gov (United States)

    Segelke, D; Täubert, H; Reinhardt, F; Thaller, G

    2016-01-01

    Recently, several research groups have demonstrated that several haplotypes may cause embryonic loss in the homozygous state. Up to now, carriers of genetic disorders were often excluded from mating, resulting in a decrease of genetic gain and a reduced number of sires available for the breeding program. Ongoing research is very likely to identify additional genetic defects causing embryonic loss and calf mortality by genotyping a large proportion of the female cattle population and sequencing key ancestors. Hence, a clear demand is present to develop a method combining selection against recessive defects (e.g., Holstein haplotypes HH1-HH5) with selection for economically beneficial traits (e.g., polled) for mating decisions. Our proposed method is a genetic index that accounts for the allele frequencies in the population and the economic value of the genetic characteristic without excluding carriers from breeding schemes. Fertility phenotypes from routine genetic evaluations were used to determine the economic value per embryo lost. Previous research has shown that embryo loss caused by HH1 and HH2 occurs later than the loss for HH3, HH4, and HH5. Therefore, an economic value of € 97 was used against HH1 and HH2 and € 70 against HH3, HH4, and HH5. For polled, € 7 per polled calf was considered. Minor allele frequencies of the defects ranged between 0.8 and 3.3%. The polled allele has a frequency of 4.1% in the German Holstein population. A genomic breeding program was simulated to study the effect of changing the selection criteria from assortative mating based on breeding values to selecting the females using the genetic index. Selection for a genetic index on the female path is a useful method to control the allele frequencies by reducing undesirable alleles and simultaneously increasing economical beneficial characteristics maintaining most of the genetic gain in production and functional traits. Additionally, we applied the genetic index to real data and

  1. Newborn Screening for Severe Combined Immunodeficiency in 11 Screening Programs in the United States

    Science.gov (United States)

    Kwan, Antonia; Abraham, Roshini S.; Currier, Robert; Brower, Amy; Andruszewski, Karen; Abbott, Jordan K.; Baker, Mei; Ballow, Mark; Bartoshesky, Louis E.; Bonagura, Vincent R.; Bonilla, Francisco A.; Brokopp, Charles; Brooks, Edward; Caggana, Michele; Celestin, Jocelyn; Church, Joseph A.; Comeau, Anne Marie; Connelly, James A.; Cowan, Morton J.; Cunningham-Rundles, Charlotte; Dasu, Trivikram; Dave, Nina; De La Morena, Maria T.; Duffner, Ulrich; Fong, Chin-To; Forbes, Lisa; Freedenberg, Debra; Gelfand, Erwin W.; Hale, Jaime E.; Celine Hanson, I.; Hay, Beverly N.; Hu, Diana; Infante, Anthony; Johnson, Daisy; Kapoor, Neena; Kay, Denise M.; Kohn, Donald B.; Lee, Rachel; Lehman, Heather; Lin, Zhili; Lorey, Fred; Abdel-Mageed, Aly; Manning, Adrienne; McGhee, Sean; Moore, Theodore B.; Naides, Stanley J.; Notarangelo, Luigi D.; Orange, Jordan S.; Pai, Sung-Yun; Porteus, Matthew; Rodriguez, Ray; Romberg, Neil; Routes, John; Ruehle, Mary; Rubenstein, Arye; Saavedra-Matiz, Carlos A.; Scott, Ginger; Scott, Patricia M.; Secord, Elizabeth; Seroogy, Christine; Shearer, William T.; Siegel, Subhadra; Silvers, Stacy K.; Stiehm, E. Richard; Sugerman, Robert W.; Sullivan, John L.; Tanksley, Susan; Tierce, Millard L.; Verbsky, James; Vogel, Beth; Walker, Rosalyn; Walkovich, Kelly; Walter, Jolan E.; Wasserman, Richard L.; Watson, Michael S.; Weinberg, Geoffrey A.; Weiner, Leonard B.; Wood, Heather; Yates, Anne B.; Puck, Jennifer M.

    2015-01-01

    IMPORTANCE Newborn screening for severe combined immunodeficiency (SCID) using assays to detect T-cell receptor excision circles (TRECs) began in Wisconsin in 2008, and SCID was added to the national recommended uniform panel for newborn screened disorders in 2010. Currently 23 states, the District of Columbia, and the Navajo Nation conduct population-wide newborn screening for SCID. The incidence of SCID is estimated at 1 in 100 000 births. OBJECTIVES To present data from a spectrum of SCID newborn screening programs, establish population-based incidence for SCID and other conditions with T-cell lymphopenia, and document early institution of effective treatments. DESIGN Epidemiological and retrospective observational study. SETTING Representatives in states conducting SCID newborn screening were invited to submit their SCID screening algorithms, test performance data, and deidentified clinical and laboratory information regarding infants screened and cases with nonnormal results. Infants born from the start of each participating program from January 2008 through the most recent evaluable date prior to July 2013 were included. Representatives from 10 states plus the Navajo Area Indian Health Service contributed data from 3 030 083 newborns screened with a TREC test. MAIN OUTCOMES AND MEASURES Infants with SCID and other diagnoses of T-cell lymphopenia were classified. Incidence and, where possible, etiologies were determined. Interventions and survival were tracked. RESULTS Screening detected 52 cases of typical SCID, leaky SCID, and Omenn syndrome, affecting 1 in 58 000 infants (95%CI, 1/46 000-1/80 000). Survival of SCID-affected infants through their diagnosis and immune reconstitution was 87%(45/52), 92%(45/49) for infants who received transplantation, enzyme replacement, and/or gene therapy. Additional interventions for SCID and non-SCID T-cell lymphopenia included immunoglobulin infusions, preventive antibiotics, and avoidance of live vaccines. Variations in

  2. Combined analog-to-digital converter

    International Nuclear Information System (INIS)

    Zhukov, A.V.; Rzhendinskaya, S.N.

    1983-01-01

    A 10-bit analog-to-digital converter (ADC) designed for operating in spectrometers with time-dependent filters is described. The ADC operation is based on combining the parallel reading and sequential counting methods. At maximum conversion time of 12 μs, timing series frequency of 25 MHz and foUr reference levels the differential nonlinearity withoUt statistical smoothing (maximum relative channel width deviation from average value) is not more than 4%

  3. Pilot-Assisted Channel Estimation for Orthogonal Multi-Carrier DS-CDMA with Frequency-Domain Equalization

    Science.gov (United States)

    Shima, Tomoyuki; Tomeba, Hiromichi; Adachi, Fumiyuki

    Orthogonal multi-carrier direct sequence code division multiple access (orthogonal MC DS-CDMA) is a combination of time-domain spreading and orthogonal frequency division multiplexing (OFDM). In orthogonal MC DS-CDMA, the frequency diversity gain can be obtained by applying frequency-domain equalization (FDE) based on minimum mean square error (MMSE) criterion to a block of OFDM symbols and can improve the bit error rate (BER) performance in a severe frequency-selective fading channel. FDE requires an accurate estimate of the channel gain. The channel gain can be estimated by removing the pilot modulation in the frequency domain. In this paper, we propose a pilot-assisted channel estimation suitable for orthogonal MC DS-CDMA with FDE and evaluate, by computer simulation, the BER performance in a frequency-selective Rayleigh fading channel.

  4. Frequency noise in frequency swept fiber laser

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier; Rottwitt, Karsten

    2013-01-01

    This Letter presents a measurement of the spectral content of frequency shifted pulses generated by a lightwave synthesized frequency sweeper. We found that each pulse is shifted in frequency with very high accuracy. We also discovered that noise originating from light leaking through the acousto......- optical modulators and forward propagating Brillouin scattering appear in the spectrum. © 2013 Optical Society of America....

  5. Factors constraining the benefit to speech understanding of combining information from low-frequency hearing and a cochlear implant.

    Science.gov (United States)

    Dorman, Michael F; Cook, Sarah; Spahr, Anthony; Zhang, Ting; Loiselle, Louise; Schramm, David; Whittingham, JoAnne; Gifford, Rene

    2015-04-01

    Many studies have documented the benefits to speech understanding when cochlear implant (CI) patients can access low-frequency acoustic information from the ear opposite the implant. In this study we assessed the role of three factors in determining the magnitude of bimodal benefit - (i) the level of CI-only performance, (ii) the magnitude of the hearing loss in the ear with low-frequency acoustic hearing and (iii) the type of test material. The patients had low-frequency PTAs (average of 125, 250 and 500 Hz) varying over a large range (70 dB HL) in the ear contralateral to the implant. The patients were tested with (i) CNC words presented in quiet (n = 105) (ii) AzBio sentences presented in quiet (n = 102), (iii) AzBio sentences in noise at +10 dB signal-to-noise ratio (SNR) (n = 69), and (iv) AzBio sentences at +5 dB SNR (n = 64). We find maximum bimodal benefit when (i) CI scores are less than 60 percent correct, (ii) hearing loss is less than 60 dB HL in low-frequencies and (iii) the test material is sentences presented against a noise background. When these criteria are met, some bimodal patients can gain 40-60 percentage points in performance relative to performance with a CI. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Predictors of parents' adherence to home exercise programs for children with developmental disabilities, regarding both exercise frequency and duration: a survey design.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Lillo-Navarro, Carmen; Montilla-Herrador, Joaquina; Gacto-Sánchez, Mariano; Franco-Sierra, María Á; Escolar-Reina, Pilar

    2017-08-01

    Many families have problems adhering to home exercise programs (HEP) for children with developmental disabilities. However, parental participation in HEP is known to have a positive effect on child-related outcome variables, as well as on parental functioning. This study examined whether the different behaviours of health professionals, and the behaviour and social characteristics of parents determine rates of parental adherence to both the frequency per week, and duration per session, of HEP for children with developmental disabilities attending paediatric services in early intervention centres. In this study, developmental disabilities include those caused by developmental delay or specific health conditions such as cerebral palsy, congenital illness, or others. Survey. Eighteen early intervention centers. Parents of children with developmental disabilities receiving HEP. A self-reported questionnaire was used to examine: whether frequency and duration of weekly exercise sessions was prescribed by physiotherapists; whether the child had received the HEP according to what was prescribed; and items related to the individual, social support, illnesses and the involvement of the health professional. Multiple logistic regression analyses examined their relative relevance. In this study 219 parents participated. The rate of adherence to the prescribed frequency and duration of the HEP was similar (61.4-57.2%). The probability of adherence to both components increased for parents who had a low perception of the existence of barriers for integrating the exercises into their daily routine (OR=2.62 and 4.83). Furthermore, other cognitive factors of parents had a variable influence. The involvement of the professional had a significant impact regarding the frequency of the HEP. Professional involvement increased the probability of exercises being followed accurately by adopting strategies such as: providing information about the progress and evolution of the exercises (OR=3

  7. Software for CATV Design and Frequency Plan Optimization

    Directory of Open Access Journals (Sweden)

    O. Hala

    2007-09-01

    Full Text Available The paper deals with the structure of a software medium used for design and sub-optimization of frequency plan in CATV networks, their description and design method. The software performance is described and a simple design example of energy balance of a simplified CATV network is given. The software was created in programming environment called Delphi and local optimization was made in Matlab.

  8. Design of 1 MHz Solid State High Frequency Power Supply

    Science.gov (United States)

    Parmar, Darshan; Singh, N. P.; Gajjar, Sandip; Thakar, Aruna; Patel, Amit; Raval, Bhavin; Dhola, Hitesh; Dave, Rasesh; Upadhay, Dishang; Gupta, Vikrant; Goswami, Niranjan; Mehta, Kush; Baruah, Ujjwal

    2017-04-01

    High Frequency Power supply (HFPS) is used for various applications like AM Transmitters, metallurgical applications, Wireless Power Transfer, RF Ion Sources etc. The Ion Source for a Neutral beam Injector at ITER-India uses inductively coupled power source at High Frequency (∼1 MHz). Switching converter based topology used to generate 1 MHz sinusoidal output is expected to have advantages on efficiency and reliability as compared to traditional RF Tetrode tubes based oscillators. In terms of Power Electronics, thermal and power coupling issues are major challenges at such a high frequency. A conceptual design for a 200 kW, 1 MHz power supply and a prototype design for a 600 W source been done. The prototype design is attempted with Class-E amplifier topology where a MOSFET is switched resonantly. The prototype uses two low power modules and a ferrite combiner to add the voltage and power at the output. Subsequently solution with Class-D H-Bridge configuration have been evaluated through simulation where module design is stable as switching device do not participate in resonance, further switching device voltage rating is substantially reduced. The rating of the modules is essentially driven by the maximum power handling capacity of the MOSFETs and ferrites in the combiner circuit. The output passive network including resonance tuned network and impedance matching network caters for soft switching and matches the load impedance to 50ohm respectively. This paper describes the conceptual design of a 200 kW high frequency power supply and experimental results of the prototype 600 W, 1 MHz source.

  9. Icobj Programming

    OpenAIRE

    Boussinot , Frédéric

    1996-01-01

    A simple and fully graphical programming method is presented, using a powerful means to combine behaviors. This programming is based on the notion of an «icobj» which has a behavioral aspect («object» part), a graphical aspect («icon» part), with an «animation» aspect. Icobj programming provides parallelism, broadcast event communication and migration through the network. An experimental system based on this approach is described in details. Its implementation with reactive scripts is also pr...

  10. Analysis of Natural Frequencies in the Universal Programs for Dynamic Processes Analysis

    Directory of Open Access Journals (Sweden)

    V. A. Trudonoshin

    2016-01-01

    Full Text Available Finding the natural frequencies of complex technical objects is an important design procedure. This type of analysis allows us to determine the resonant frequencies and, as a consequence, to avoid their adverse impact on dynamics the projected object or that of under study. This applies to both the objects with distributed parameters, and the objects with lumped parameters. As to the first type of the objects, in almost every package that implements the finite element method, this type of analysis is available. The situation is different for the objects with lumped parameters. Methods to have the mathematical models for these objects look to implicit methods of numerical integration of ordinary differential equations. And the component equations of the reactive branches are sampled by numerical integration formulas, and the derivatives of state variables disappear from the vector of the unknowns of a mathematical model. In this case, talk about the implementation of the procedure for finding natural frequencies by finding eigenvalues is simply unnecessary. In cases where a mathematical model of the object is given in the normal Cauchy form, obtaining the natural frequencies is reduced to finding the eigenvalues of the coefficient matrix. There are methods to form the mathematical models in which the derivatives of the state variables make a sub-vector of the vector of unknowns. These are generalized, advanced nodal methods, and an advanced nodal one for mechanical systems. There can be a try for reduction of the mathematical models of objects, obtained by these methods, to the normal Cauchy form. The article discusses a similar procedure for the generalized and advanced nodal methods. As for the extended nodal method for mechanical systems there is specifics the article does not show. For the model obtained by generalized method the vector of unknown variables is permutated so that a sub-vector of the derivatives of the state variables was in

  11. Adolescent Sexual Behaviors at Varying Levels of Substance Use Frequency

    Science.gov (United States)

    Floyd, Leah J.; Latimer, William

    2010-01-01

    Combining substance use and sex compounds the risk of contracting sexually transmitted diseases, including HIV. However, the association between substance use and sexual behaviors may vary by substance and sexual behavior. The current study sought to examine the relationship between alcohol and marijuana use frequency and specific sexual…

  12. Combining norms to prove termination

    DEFF Research Database (Denmark)

    Genaim, S.; Codish, M.; Gallagher, John Patrick

    2002-01-01

    Automatic termination analysers typically measure the size of terms applying norms which are mappings from terms to the natural numbers. This paper illustrates howt o enable the use of size functions defined as tuples of these simpler norm functions. This approach enables us to simplify the probl...... of the recursive data-types in the program, is often a suitable choice. We first demonstrate the power of combining norm functions and then the adequacy of combining norms based on regular types....

  13. Observations on the Reliability of Rubidium Frequency Standards on Block 2/2A GPS Satellites

    Science.gov (United States)

    Dieter, Gary L.

    1996-01-01

    Currently, the block 2/2A Global Positioning System (GPS) satellites are equipped with two rubidium frequency standards. These frequency standards were originally intended to serve as the back-ups to two cesium frequency standards. As the constellation ages, the master Control Station is forced to initialize and increasing number or rubidium frequency standards. Unfortunately the operational use of these frequency standards has not lived up to initial expectations. Although the performance of these rubidium frequency standards has met and even exceeded GPS requirements, their reliability has not. The number of unscheduled outage times and the short operational lifetimes of the rubidium frequency standards compare poorly to the track record of the cesium frequency standards. Only a small number of rubidium frequency standards have actually been made operational. Of these, a large percentage have exhibited poor reliability. If this trend continues, it is unlikely that the rubidium frequency standards will help contribute to the navigation payload meeting program specification.

  14. Investigation of power and frequency for 3D conformal MRI-controlled transurethral ultrasound therapy with a dual frequency multi-element transducer.

    Science.gov (United States)

    N'djin, William Apoutou; Burtnyk, Mathieu; Bronskill, Michael; Chopra, Rajiv

    2012-01-01

    Transurethral ultrasound therapy uses real-time magnetic resonance (MR) temperature feedback to enable the 3D control of thermal therapy accurately in a region within the prostate. Previous canine studies showed the feasibility of this method in vivo. The aim of this study was to reduce the procedure time, while maintaining targeting accuracy, by investigating new combinations of treatment parameters. Simulations and validation experiments in gel phantoms were used, with a collection of nine 3D realistic target prostate boundaries obtained from previous preclinical studies, where multi-slice MR images were acquired with the transurethral device in place. Acoustic power and rotation rate were varied based on temperature feedback at the prostate boundary. Maximum acoustic power and rotation rate were optimised interdependently, as a function of prostate radius and transducer operating frequency. The concept of dual frequency transducers was studied, using the fundamental frequency or the third harmonic component depending on the prostate radius. Numerical modelling enabled assessment of the effects of several acoustic parameters on treatment outcomes. The range of treatable prostate radii extended with increasing power, and tended to narrow with decreasing frequency. Reducing the frequency from 8 MHz to 4 MHz or increasing the surface acoustic power from 10 to 20 W/cm(2) led to treatment times shorter by up to 50% under appropriate conditions. A dual frequency configuration of 4/12 MHz with 20 W/cm(2) ultrasound intensity exposure can treat entire prostates up to 40 cm(3) in volume within 30 min. The interdependence between power and frequency may, however, require integrating multi-parametric functions in the controller for future optimisations.

  15. COMBINE7.0 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

    Energy Technology Data Exchange (ETDEWEB)

    Woo Y. Yoon; David W. Nigg

    2008-09-01

    -ordinate transport code, is incoprated into COMBINE7.0. As an option, the 167 fine-group constants generated by COMBINE portion in the program can be used to cacluate regionwise spectra in the ANISN portion, all internally to reflect the one-dimensional transport correction. Results for the criticality validation calculations are included as a part of verification and validation.

  16. COMBINE7.0 - A Portable ENDF/B-VII.0 Based Neutron Spectrum and Cross-Section Generation Program

    International Nuclear Information System (INIS)

    Yoon, Woo Y.; Nigg, David W.

    2008-01-01

    -ordinate transport code, is incoprated into COMBINE7.0. As an option, the 167 fine-group constants generated by COMBINE portion in the program can be used to cacluate regionwise spectra in the ANISN portion, all internally to reflect the one-dimensional transport correction. Results for the criticality validation calculations are included as a part of verification and validation.

  17. Frequency of exclusive breastfeeding and its affecting factors in Tehran, 2011.

    Directory of Open Access Journals (Sweden)

    Hossein Dalili

    2014-07-01

    Full Text Available This study was designed to assess the frequency of exclusive breastfeeding in two health centers of Shahid Beheshti University of Medical sciences in Khak Sefid, Tehran, Iran. A total of 175 mothers, referred for the third dose of their infants' DPT vaccination program participated in the study by completing a questionnaire regarding characteristics of their pregnancy, delivery and exclusive breastfeeding within the first six months of birth. Two-variable analysis and logistic regression test were applied to evaluate factors influencing exclusive breastfeeding. Results indicated that the frequency of exclusive breastfeeding, i.e., breastfeeding within the first six months of birth without the use of any other food with or without vitamin supplementation, was 31.17% (95% CI=23.77%-38.57%, which means 48 infants of 154<179 days old Among 154 infants (<179 days old 48 did not have a history of being separated from their mothers. In logistic regression analysis, the variables which were directly associated with exclusive breastfeeding, with 0.05 significance level of alpha, included breastfeeding within the first hour of birth, eight times or more breastfeeding per day and receiving breastfeeding education during pregnancy. Variables with a negative association with breastfeeding included lack of breast milk, presence of a breast problem that could hinder breastfeeding, bottle feeding, physician or family's advice not to breastfeed and infant's refusal to breastfeed. Frequency of breastfeeding within the six months of birth is less than similar frequencies which are obtained by asking about breastfeeding on the day of the interview. It is recommended to apply real frequency for assessment, evaluation and programming of exclusive breastfeeding during the first six months of birth.

  18. A novel optogenetically tunable frequency modulating oscillator.

    Directory of Open Access Journals (Sweden)

    Tarun Mahajan

    Full Text Available Synthetic biology has enabled the creation of biological reconfigurable circuits, which perform multiple functions monopolizing a single biological machine; Such a system can switch between different behaviours in response to environmental cues. Previous work has demonstrated switchable dynamical behaviour employing reconfigurable logic gate genetic networks. Here we describe a computational framework for reconfigurable circuits in E.coli using combinations of logic gates, and also propose the biological implementation. The proposed system is an oscillator that can exhibit tunability of frequency and amplitude of oscillations. Further, the frequency of operation can be changed optogenetically. Insilico analysis revealed that two-component light systems, in response to light within a frequency range, can be used for modulating the frequency of the oscillator or stopping the oscillations altogether. Computational modelling reveals that mixing two colonies of E.coli oscillating at different frequencies generates spatial beat patterns. Further, we show that these oscillations more robustly respond to input perturbations compared to the base oscillator, to which the proposed oscillator is a modification. Compared to the base oscillator, the proposed system shows faster synchronization in a colony of cells for a larger region of the parameter space. Additionally, the proposed oscillator also exhibits lesser synchronization error in the transient period after input perturbations. This provides a strong basis for the construction of synthetic reconfigurable circuits in bacteria and other organisms, which can be scaled up to perform functions in the field of time dependent drug delivery with tunable dosages, and sets the stage for further development of circuits with synchronized population level behaviour.

  19. High-frequency harmonic imaging of the eye

    Science.gov (United States)

    Silverman, Ronald H.; Coleman, D. Jackson; Ketterling, Jeffrey A.; Lizzi, Frederic L.

    2005-04-01

    Purpose: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. Methods: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. Results: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. Conclusion: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.

  20. The thermal history of the plasma and high-frequency gravitons

    International Nuclear Information System (INIS)

    Giovannini, Massimo

    2009-01-01

    Possible deviations from a radiation-dominated evolution, occurring prior to the synthesis of light nuclei, impacted on the spectral energy density of high-frequency gravitons. For a systematic scrutiny of this situation, the ΛCDM paradigm must be complemented by (at least two) physical parameters describing, respectively, a threshold frequency and a slope. The supplementary frequency scale sets the lower border of a high-frequency domain where the spectral energy grows with a slope which depends, predominantly, upon the total sound speed of the plasma right after inflation. While the infrared region of the graviton energy spectrum is nearly scale invariant, the expected signals for typical frequencies larger than 0.01 nHz are hereby analyzed in a model-independent framework by requiring that the total sound speed of the post-inflationary plasma be smaller than the speed of light. Current (e.g., low-frequency) upper limits on the tensor power spectra (determined from the combined analysis of the three large-scale data sets) are shown to be compatible with a detectable signal in the frequency range of wideband interferometers. In the present context, the scrutiny of the early evolution of the sound speed of the plasma can then be mapped onto a reliable strategy of parameter extraction including not only the well-established cosmological observables but also the forthcoming data from wideband interferometers.

  1. Development of computer program ENAUDIBL for computation of the sensation levels of multiple, complex, intrusive sounds in the presence of residual environmental masking noise

    Energy Technology Data Exchange (ETDEWEB)

    Liebich, R. E.; Chang, Y.-S.; Chun, K. C.

    2000-03-31

    The relative audibility of multiple sounds occurs in separate, independent channels (frequency bands) termed critical bands or equivalent rectangular (filter-response) bandwidths (ERBs) of frequency. The true nature of human hearing is a function of a complex combination of subjective factors, both auditory and nonauditory. Assessment of the probability of individual annoyance, community-complaint reaction levels, speech intelligibility, and the most cost-effective mitigation actions requires sensation-level data; these data are one of the most important auditory factors. However, sensation levels cannot be calculated by using single-number, A-weighted sound level values. This paper describes specific steps to compute sensation levels. A unique, newly developed procedure is used, which simplifies and improves the accuracy of such computations by the use of maximum sensation levels that occur, for each intrusive-sound spectrum, within each ERB. The newly developed program ENAUDIBL makes use of ERB sensation-level values generated with some computational subroutines developed for the formerly documented program SPECTRAN.

  2. Simultaneously measured signals in scanning probe microscopy with a needle sensor: frequency shift and tunneling current.

    Science.gov (United States)

    Morawski, Ireneusz; Voigtländer, Bert

    2010-03-01

    We present combined noncontact scanning force microscopy and tunneling current images of a platinum(111) surface obtained by means of a 1 MHz quartz needle sensor. The low-frequency circuit of the tunneling current was combined with a high-frequency signal of the quartz resonator enabling full electrical operation of the sensor. The frequency shift and the tunneling current were detected simultaneously, while the feedback control loop of the topography signal was fed using one of them. In both cases, the free signal that was not connected to the feedback loop reveals proportional-integral controller errorlike behavior, which is governed by the time derivative of the topography signal. A procedure is proposed for determining the mechanical oscillation amplitude by utilizing the tunneling current also including the average tip-sample work function.

  3. Spectral and spectral-frequency methods of investigating atmosphereless bodies of the Solar system

    International Nuclear Information System (INIS)

    Busarev, Vladimir V; Prokof'eva-Mikhailovskaya, Valentina V; Bochkov, Valerii V

    2007-01-01

    A method of reflectance spectrophotometry of atmosphereless bodies of the Solar system, its specificity, and the means of eliminating basic spectral noise are considered. As a development, joining the method of reflectance spectrophotometry with the frequency analysis of observational data series is proposed. The combined spectral-frequency method allows identification of formations with distinctive spectral features, and estimations of their sizes and distribution on the surface of atmospherelss celestial bodies. As applied to investigations of asteroids 21 Lutetia and 4 Vesta, the spectral frequency method has given us the possibility of obtaining fundamentally new information about minor planets. (instruments and methods of investigation)

  4. Singly-resonant sum frequency generation of visible light in a semiconductor disk laser

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Schlosser, P.J.; Hastie, J.E.

    2009-01-01

    In this paper a generic approach for visible light generation is presented. It is based on sum frequency generation between a semiconductor disk laser and a solid-state laser, where the frequency mixing is achieved within the cavity of the semiconductor disk laser using a singlepass of the solid......-state laser light. This exploits the good beam quality and high intra-cavity power present in the semiconductor disk laser to achieve high conversion efficiency. Combining sum frequency mixing and semiconductor disk lasers in this manner allows in principle for generation of any wavelength within the visible...

  5. Binocular combination in abnormal binocular vision.

    Science.gov (United States)

    Ding, Jian; Klein, Stanley A; Levi, Dennis M

    2013-02-08

    We investigated suprathreshold binocular combination in humans with abnormal binocular visual experience early in life. In the first experiment we presented the two eyes with equal but opposite phase shifted sine waves and measured the perceived phase of the cyclopean sine wave. Normal observers have balanced vision between the two eyes when the two eyes' images have equal contrast (i.e., both eyes contribute equally to the perceived image and perceived phase = 0°). However, in observers with strabismus and/or amblyopia, balanced vision requires a higher contrast image in the nondominant eye (NDE) than the dominant eye (DE). This asymmetry between the two eyes is larger than predicted from the contrast sensitivities or monocular perceived contrast of the two eyes and is dependent on contrast and spatial frequency: more asymmetric with higher contrast and/or spatial frequency. Our results also revealed a surprising NDE-to-DE enhancement in some of our abnormal observers. This enhancement is not evident in normal vision because it is normally masked by interocular suppression. However, in these abnormal observers the NDE-to-DE suppression was weak or absent. In the second experiment, we used the identical stimuli to measure the perceived contrast of a cyclopean grating by matching the binocular combined contrast to a standard contrast presented to the DE. These measures provide strong constraints for model fitting. We found asymmetric interocular interactions in binocular contrast perception, which was dependent on both contrast and spatial frequency in the same way as in phase perception. By introducing asymmetric parameters to the modified Ding-Sperling model including interocular contrast gain enhancement, we succeeded in accounting for both binocular combined phase and contrast simultaneously. Adding binocular contrast gain control to the modified Ding-Sperling model enabled us to predict the results of dichoptic and binocular contrast discrimination experiments

  6. Programmed Instruction for Teaching Java: Consideration of Learn Unit Frequency and Rule-Test Performance

    Science.gov (United States)

    Emurian, Henry H.

    2007-01-01

    At the beginning of a Java computer programming course, nine students in an undergraduate class and nine students in a graduate class completed a web-based programmed instruction tutoring system that taught a simple computer program. All students exited the tutor with an identical level of skill, at least as determined by the tutor's required…

  7. LOOP- SIMULATION OF THE AUTOMATIC FREQUENCY CONTROL SUBSYSTEM OF A DIFFERENTIAL MINIMUM SHIFT KEYING RECEIVER

    Science.gov (United States)

    Davarian, F.

    1994-01-01

    The LOOP computer program was written to simulate the Automatic Frequency Control (AFC) subsystem of a Differential Minimum Shift Keying (DMSK) receiver with a bit rate of 2400 baud. The AFC simulated by LOOP is a first order loop configuration with a first order R-C filter. NASA has been investigating the concept of mobile communications based on low-cost, low-power terminals linked via geostationary satellites. Studies have indicated that low bit rate transmission is suitable for this application, particularly from the frequency and power conservation point of view. A bit rate of 2400 BPS is attractive due to its applicability to the linear predictive coding of speech. Input to LOOP includes the following: 1) the initial frequency error; 2) the double-sided loop noise bandwidth; 3) the filter time constants; 4) the amount of intersymbol interference; and 5) the bit energy to noise spectral density. LOOP output includes: 1) the bit number and the frequency error of that bit; 2) the computed mean of the frequency error; and 3) the standard deviation of the frequency error. LOOP is written in MS SuperSoft FORTRAN 77 for interactive execution and has been implemented on an IBM PC operating under PC DOS with a memory requirement of approximately 40K of 8 bit bytes. This program was developed in 1986.

  8. Discrete-time nonlinear damping backstepping control with observers for rejection of low and high frequency disturbances

    Science.gov (United States)

    Kim, Wonhee; Chen, Xu; Lee, Youngwoo; Chung, Chung Choo; Tomizuka, Masayoshi

    2018-05-01

    A discrete-time backstepping control algorithm is proposed for reference tracking of systems affected by both broadband disturbances at low frequencies and narrow band disturbances at high frequencies. A discrete time DOB, which is constructed based on infinite impulse response filters is applied to compensate for narrow band disturbances at high frequencies. A discrete-time nonlinear damping backstepping controller with an augmented observer is proposed to track the desired output and to compensate for low frequency broadband disturbances along with a disturbance observer, for rejecting narrow band high frequency disturbances. This combination has the merit of simultaneously compensating both broadband disturbances at low frequencies and narrow band disturbances at high frequencies. The performance of the proposed method is validated via experiments.

  9. A mechanism for frequency modulation in songbirds shared with humans.

    Science.gov (United States)

    Amador, Ana; Margoliash, Daniel

    2013-07-03

    In most animals that vocalize, control of fundamental frequency is a key element for effective communication. In humans, subglottal pressure controls vocal intensity but also influences fundamental frequency during phonation. Given the underlying similarities in the biomechanical mechanisms of vocalization in humans and songbirds, songbirds offer an attractive opportunity to study frequency modulation by pressure. Here, we present a novel technique for dynamic control of subsyringeal pressure in zebra finches. By regulating the opening of a custom-built fast valve connected to the air sac system, we achieved partial or total silencing of specific syllables, and could modify syllabic acoustics through more complex manipulations of air sac pressure. We also observed that more nuanced pressure variations over a limited interval during production of a syllable concomitantly affected the frequency of that syllable segment. These results can be explained in terms of a mathematical model for phonation that incorporates a nonlinear description for the vocal source capable of generating the observed frequency modulations induced by pressure variations. We conclude that the observed interaction between pressure and frequency was a feature of the source, not a result of feedback control. Our results indicate that, beyond regulating phonation or its absence, regulation of pressure is important for control of fundamental frequencies of vocalizations. Thus, although there are separate brainstem pathways for syringeal and respiratory control of song production, both can affect airflow and frequency. We hypothesize that the control of pressure and frequency is combined holistically at higher levels of the vocalization pathways.

  10. Single-transducer dual-frequency ultrasound generation to enhance acoustic cavitation.

    Science.gov (United States)

    Liu, Hao-Li; Hsieh, Chao-Ming

    2009-03-01

    Dual- or multiple-frequency ultrasound stimulation is capable of effectively enhancing the acoustic cavitation effect over single-frequency ultrasound. Potential application of this sonoreactor design has been widely proposed such as on sonoluminescence, sonochemistry enhancement, and transdermal drug release enhancement. All currently available sonoreactor designs employed multiple piezoelectric transducers for generating single-frequency ultrasonic waves separately and then these waves were mixed and interfered in solutions. The purpose of this research is to propose a novel design of generating dual-frequency ultrasonic waves with single piezoelectric elements, thereby enhancing acoustic cavitation. Macroscopic bubbles were detected optically, and they were quantified at either a single-frequency or for different frequency combinations for determining their efficiency for enhancing acoustic cavitation. Visible bubbles were optically detected and hydrogen peroxide was measured to quantify acoustic cavitation. Test water samples with different gas concentrations and different power levels were used to determine the efficacy of enhancing acoustic cavitation of this design. The spectrum obtained from the backscattered signals was also recorded and examined to confirm the occurrence of stable cavitation. The results confirmed that single-element dual-frequency ultrasound stimulation can enhance acoustic cavitation. Under certain testing conditions, the generation of bubbles can be enhanced up to a level of five times higher than the generation of bubbles in single-frequency stimulation, and can increase the hydrogen peroxide production up to an increase of one fold. This design may serve as a useful alternative for future sonoreactor design owing to its simplicity to produce dual- or multiple-frequency ultrasound.

  11. Improvement of Frequency Locking Algorithm for Atomic Frequency Standards

    Science.gov (United States)

    Park, Young-Ho; Kang, Hoonsoo; Heyong Lee, Soo; Eon Park, Sang; Lee, Jong Koo; Lee, Ho Seong; Kwon, Taeg Yong

    2010-09-01

    The authors describe a novel method of frequency locking algorithm for atomic frequency standards. The new algorithm for locking the microwave frequency to the Ramsey resonance is compared with the old one that had been employed in the cesium atomic beam frequency standards such as NIST-7 and KRISS-1. Numerical simulations for testing the performance of the algorithm show that the new method has a noise filtering performance superior to the old one by a factor of 1.2 for the flicker signal noise and 1.4 for random-walk signal noise. The new algorithm can readily be used to enhance the frequency stability for a digital servo employing the slow square wave frequency modulation.

  12. Extraction of RBM frequency of a (10, 0) SWNT using MATLAB

    Science.gov (United States)

    Yadav, Monika; Negi, Sunita

    2018-05-01

    In the last few decades carbon nanotubes (CNT) have attracted great interest for future applications of these tubes in the field of electronics, composite material and drug delivery etc. The normal modes associated with a carbon nanotube are therefore important to be understood for a better understanding of their behavior. In this paper we report the frequency of the most important "Radial Breathing Mode (RBM)" associated with a single walled carbon nanotube. This is done with the help of a MATLAB program. We observe a RBM frequency associated with a (10, 0) single walled carbon nanotube at 340 cm-1. A very slow frequency component is also observed to be associated with the RBM of the carbon nanotube as reported earlier also. This method used for the extraction of RBM frequency is observed to be simple and fast as compared with the other methods.

  13. Enhanced Performance by Time-Frequency-Phase Feature for EEG-Based BCI Systems

    Directory of Open Access Journals (Sweden)

    Baolei Xu

    2014-01-01

    Full Text Available We introduce a new motor parameter imagery paradigm using clench speed and clench force motor imagery. The time-frequency-phase features are extracted from mu rhythm and beta rhythms, and the features are optimized using three process methods: no-scaled feature using “MIFS” feature selection criterion, scaled feature using “MIFS” feature selection criterion, and scaled feature using “mRMR” feature selection criterion. Support vector machines (SVMs and extreme learning machines (ELMs are compared for classification between clench speed and clench force motor imagery using the optimized feature. Our results show that no significant difference in the classification rate between SVMs and ELMs is found. The scaled feature combinations can get higher classification accuracy than the no-scaled feature combinations at significant level of 0.01, and the “mRMR” feature selection criterion can get higher classification rate than the “MIFS” feature selection criterion at significant level of 0.01. The time-frequency-phase feature can improve the classification rate by about 20% more than the time-frequency feature, and the best classification rate between clench speed motor imagery and clench force motor imagery is 92%. In conclusion, the motor parameter imagery paradigm has the potential to increase the direct control commands for BCI control and the time-frequency-phase feature has the ability to improve BCI classification accuracy.

  14. Propulsion/ASME Rocket-Based Combined Cycle Activities in the Advanced Space Transportation Program Office

    Science.gov (United States)

    Hueter, Uwe; Turner, James

    1998-01-01

    NASA's Office Of Aeronautics and Space Transportation Technology (OASTT) has establish three major coals. "The Three Pillars for Success". The Advanced Space Transportation Program Office (ASTP) at the NASA's Marshall Space Flight Center in Huntsville,Ala. focuses on future space transportation technologies under the "Access to Space" pillar. The Advanced Reusable Technologies (ART) Project, part of ASTP, focuses on the reusable technologies beyond those being pursued by X-33. The main activity over the past two and a half years has been on advancing the rocket-based combined cycle (RBCC) technologies. In June of last year, activities for reusable launch vehicle (RLV) airframe and propulsion technologies were initiated. These activities focus primarily on those technologies that support the year 2000 decision to determine the path this country will take for Space Shuttle and RLV. In February of this year, additional technology efforts in the reusable technologies were awarded. The RBCC effort that was completed early this year was the initial step leading to flight demonstrations of the technology for space launch vehicle propulsion. Aerojet, Boeing-Rocketdyne and Pratt & Whitney were selected for a two-year period to design, build and ground test their RBCC engine concepts. In addition, ASTROX, Pennsylvania State University (PSU) and University of Alabama in Huntsville also conducted supporting activities. The activity included ground testing of components (e.g., injectors, thrusters, ejectors and inlets) and integrated flowpaths. An area that has caused a large amount of difficulty in the testing efforts is the means of initiating the rocket combustion process. All three of the prime contractors above were using silane (SiH4) for ignition of the thrusters. This follows from the successful use of silane in the NASP program for scramjet ignition. However, difficulties were immediately encountered when silane (an 80/20 mixture of hydrogen/silane) was used for rocket

  15. Low-Frequency Loudspeaker-Room Simulation Using Finite Differences in the Time Domain-Part 1: Analysis

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    Small- and medium-size rectangular rooms have a strong influence on the low-frequency performance of loudspeakers. A simulation program based on the finite-difference time-domain (FDTD) method is introduced to analyze the sound field produced by loudspeakers in rectangular rooms at low frequencies...

  16. Stimulus Ratio and Level Dependence of Low- and Mid-Frequency Distortion-Product Otoacoustic Emissions

    DEFF Research Database (Denmark)

    Christensen, Anders Tornvig; Ordoñez, Rodrigo Pizarro; Hammershøi, Dorte

    2014-01-01

    ratios f2/f1 (1.05-1.50) and three stimulus sound pressure levels L1/L2 (65/45, 65/55, 70/60) were measured in each configuration. The DPOAE response was isolated with the discrete Fourier transformation (DFT). The DFT measures the DPOAE response accurately only when the DPOAE frequency and both stimulus...... examples of low-frequency DPOAEs exist in the literature. Overcoming the decreasing response level and increasing noise level with decreasing frequency may provide a non-invasive window into the inner-ear mechanics of low-frequency hearing. Eighteen out of 21 young human adults screened (19-30 years) had......-frequency range. The stimulus level has similar effects in both frequency ranges, that is, the ratio-magnitude response increases and broadens with increasing level. The combined observations could indicate a difference between apical and basal cochlear physiology....

  17. GPS satellite clock determination in case of inter-frequency clock biases for triple-frequency precise point positioning

    Science.gov (United States)

    Guo, Jiang; Geng, Jianghui

    2017-12-01

    Significant time-varying inter-frequency clock biases (IFCBs) within GPS observations prevent the application of the legacy L1/L2 ionosphere-free clock products on L5 signals. Conventional approaches overcoming this problem are to estimate L1/L5 ionosphere-free clocks in addition to their L1/L2 counterparts or to compute IFCBs between the L1/L2 and L1/L5 clocks which are later modeled through a harmonic analysis. In contrast, we start from the undifferenced uncombined GNSS model and propose an alternative approach where a second satellite clock parameter dedicated to the L5 signals is estimated along with the legacy L1/L2 clock. In this manner, we do not need to rely on the correlated L1/L2 and L1/L5 ionosphere-free observables which complicates triple-frequency GPS stochastic models, or account for the unfavorable time-varying hardware biases in undifferenced GPS functional models since they can be absorbed by the L5 clocks. An extra advantage over the ionosphere-free model is that external ionosphere constraints can potentially be introduced to improve PPP. With 27 days of triple-frequency GPS data from globally distributed stations, we find that the RMS of the positioning differences between our GPS model and all conventional models is below 1 mm for all east, north and up components, demonstrating the effectiveness of our model in addressing triple-frequency observations and time-varying IFCBs. Moreover, we can combine the L1/L2 and L5 clocks derived from our model to calculate precisely the L1/L5 clocks which in practice only depart from their legacy counterparts by less than 0.006 ns in RMS. Our triple-frequency GPS model proves convenient and efficient in combating time-varying IFCBs and can be generalized to more than three frequency signals for satellite clock determination.

  18. The Functional Programming Language R and the Paradigm of Dynamic Scientific Programming

    NARCIS (Netherlands)

    Trancón y Widemann, B.; Bolz, C.F.; Grelck, C.; Loidl, H.-W.; Peña, R.

    2013-01-01

    R is an environment and functional programming language for statistical data analysis and visualization. Largely unknown to the functional programming community, it is popular and influential in many empirical sciences. Due to its integrated combination of dynamic and reflective scripting on one

  19. FREQUENCY-DEPENDENT DISPERSION MEASURES AND IMPLICATIONS FOR PULSAR TIMING

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, J. M. [Astronomy Department, Cornell University, Ithaca, NY 14853 (United States); Shannon, R. M. [CSIRO Astronomy and Space Science, Box 76, Epping, NSW 1710 (Australia); Stinebring, D. R., E-mail: cordes@astro.cornell.edu, E-mail: ryan.shannon@csiro.au, E-mail: dan.stinebring@oberlin.edu [Department of Physics and Astronomy, Oberlin College, Oberlin, OH 44074 (United States)

    2016-01-20

    The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency{sup 2}). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ∼ 4 × 10{sup −5} pc cm{sup −3} for pulsars at ∼1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm{sup −3} but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

  20. A Bootstrapping Model of Frequency and Context Effects in Word Learning.

    Science.gov (United States)

    Kachergis, George; Yu, Chen; Shiffrin, Richard M

    2017-04-01

    Prior research has shown that people can learn many nouns (i.e., word-object mappings) from a short series of ambiguous situations containing multiple words and objects. For successful cross-situational learning, people must approximately track which words and referents co-occur most frequently. This study investigates the effects of allowing some word-referent pairs to appear more frequently than others, as is true in real-world learning environments. Surprisingly, high-frequency pairs are not always learned better, but can also boost learning of other pairs. Using a recent associative model (Kachergis, Yu, & Shiffrin, 2012), we explain how mixing pairs of different frequencies can bootstrap late learning of the low-frequency pairs based on early learning of higher frequency pairs. We also manipulate contextual diversity, the number of pairs a given pair appears with across training, since it is naturalistically confounded with frequency. The associative model has competing familiarity and uncertainty biases, and their interaction is able to capture the individual and combined effects of frequency and contextual diversity on human learning. Two other recent word-learning models do not account for the behavioral findings. Copyright © 2016 Cognitive Science Society, Inc.