WorldWideScience

Sample records for produces inverted phototaxis

  1. Fingering instabilities in bacterial community phototaxis

    Science.gov (United States)

    Vps, Ritwika; Man Wah Chau, Rosanna; Casey Huang, Kerwyn; Gopinathan, Ajay

    Synechocystis sp PCC 6803 is a phototactic cyanobacterium that moves directionally in response to a light source. During phototaxis, these bacterial communities show emergent spatial organisation resulting in the formation of finger-like projections at the propagating front. In this study, we propose an analytical model that elucidates the underlying physical mechanisms which give rise to these spatial patterns. We describe the migrating front during phototaxis as a one-dimensional curve by considering the effects of phototactic bias, diffusion and surface tension. By considering the propagating front as composed of perturbations to a flat solution and using linear stability analysis, we predict a critical bias above which the finger-like projections appear as instabilities. We also predict the wavelengths of the fastest growing mode and the critical mode above which the instabilities disappear. We validate our predictions through comparisons to experimental data obtained by analysing images of phototaxis in Synechocystis communities. Our model also predicts the observed loss of instabilities in taxd1 mutants (cells with inactive TaxD1, an important photoreceptor in finger formation), by considering diffusion in mutually perpendicular directions and a lower, negative bias.

  2. MODIFICATION OF SEA ANEMONE BEHAVIOR BY SYMBIOTIC ZOOXANTHELLAE: PHOTOTAXIS.

    Science.gov (United States)

    Pearse, Vicki Buchsbaum

    1974-12-01

    The sea anemone Anthopleura elegantissima, with and without endosymbiotic zooxanthellae, was tested for evidence of phototactic behavior. Anemones with zooxanthellae always displayed phototaxis, either positive or negative depending on the experimental light intensity and the light intensity of the habitat from which the animals were taken. Anemones without zooxanthellae-even those that had previously harbored zooxanthellae and that were genetically identical clone-mates of phototactic individuals-never displayed phototaxis, appearing completely indifferent to light and shade. The results indicate that phototaxis in this sea anemone depends directly on the presence of its symbiotic algae. It is suggested that the flexible phototactic behavior of the anemone may play an important role in favorably regulating the amount of light to which the zooxanthellae are exposed.

  3. Influence of static magnetic fields in phototaxis and osmotic stress in Gymnodinium catenatum (Dinophyceae).

    Science.gov (United States)

    Vale, Paulo

    2017-07-01

    Phototaxis response of the toxic microalgae Gymnodinium catenatum was studied in vitro. The percentage of cells remaining at mid-depth 20 min after stirring increased with solar radio, X-ray and solar flares output. It also increased with geomagnetic activity and temperature, and was dependent on culture time. Increase in the local static magnetic field with a permanent magnet did not influence the positive phototaxis response. However, survival and growth to a provoked hypo-osmotic shock in an altered static magnetic field was dependent on culture time and geomagnetic activity at a threshold below 22 nT. The results from phototaxis and hypo-osmotic shock experiments were in line with the previous hypothesis for the existence of two separate deleterious mechanisms conditioning the natural blooms of G. catenatum: one that is dependent on solar radiation and the other that is related to geomagnetic activity. Variations in electromagnetic fields caused by tectonic activity were also capable of influencing G. catenatum phototaxis and growth response in vitro.

  4. On the relation between phototaxis and photosynthesis in Rhodospirillum Rubrum

    NARCIS (Netherlands)

    Thomas, J.B.; Nijenhuis, L.E.

    1950-01-01

    The relation between phototaxis and photosynthesis in Rhodospirillum rubrum has been studied. The light intensity at which saturation is reached in photosynthesis proved to coincide with that at which the contrast sensitivity starts to decrease. Potassium cyanide, which preferably inhibits the

  5. Making Sense of Protists – aspects of phototaxis and chemo sensory behavior

    DEFF Research Database (Denmark)

    Moldrup, Morten

    07) of Kryptoperidinium foliaceum, showed that the eyespot in two of these strains have degenerated following decades in culture. Thus, previous studies have failed to report positive phototaxis due to loss of directionality caused by the degenerated eyespot. The results are discussed in a broader...... “protozoan filter” for fecal pellets in the water column. The photosynthetic dinoflagellate Karlodinium is known to form massive blooms worldwide and often these are associated with fish kills. Here we show that Karlodinum armiger can reverse the traditional trophic pathway from primary producers to copepods...... or a quite recently established symbiont. Here we present data from a number of experiments in which we tried to replace the symbionts in M. rubrum by supplying a number of different cryptophyte species belonging to different cryptophyte clades. Growth and ingestion rates of M. rubrum fed these cryptophytes...

  6. Age- and Wavelength-Dependency of Drosophila Larval Phototaxis and Behavioral Responses to Natural Lighting Conditions

    Directory of Open Access Journals (Sweden)

    Simon G. Sprecher

    2017-04-01

    Full Text Available Animals use various environmental cues as key determinant for their behavioral decisions. Visual systems are hereby responsible to translate light-dependent stimuli into neuronal encoded information. Even though the larval eyes of the fruit fly Drosophila melanogaster are comparably simple, they comprise two types of photoreceptor neurons (PRs, defined by different Rhodopsin genes expressed. Recent findings support that for light avoidance Rhodopsin5 (Rh5 expressing photoreceptors are crucial, while Rhodopsin6 (Rh6 expressing photoreceptors are dispensable under laboratory conditions. However, it remains debated how animals change light preference during larval live. We show that larval negative phototaxis is age-independent as it persists in larvae from foraging to wandering developmental stages. Moreover, if spectrally different Rhodopsins are employed for the detection of different wavelength of light remains unexplored. We found that negative phototaxis can be elicit by light with wavelengths ranging from ultraviolet (UV to green. This behavior is uniquely mediated by Rh5 expressing photoreceptors, and therefore suggest that this photoreceptor-type is able to perceive UV up to green light. In contrast to laboratory our field experiments revealed that Drosophila larvae uses both types of photoreceptors under natural lighting conditions. All our results, demonstrate that Drosophila larval eyes mediate avoidance of light stimuli with a wide, ecological relevant range of quantity (intensities and quality (wavelengths. Thus, the two photoreceptor-types appear more likely to play a role in different aspects of phototaxis under natural lighting conditions, rather than color discrimination.

  7. Loss of phototaxis and degeneration of an eyespot in long-term algal cultures: evidence from ultrastructure and behaviour in the dinoflagellate Kryptoperidinium foliaceum.

    Science.gov (United States)

    Moldrup, Morten; Moestrup, Øjvind; Hansen, Per Juel

    2013-01-01

    Phototaxis provides phytoplankton with the means to orient themselves in a light gradient. This is accomplished using an eyespot and associated organelles. For the dinoflagellate Kryptoperidinium foliaceum, which has been described as having one of the most elaborate eyespot complexes known, positive phototaxis has hitherto not been reported. In this study, we show that a newly isolated strain of K. foliaceum is indeed capable of positive phototaxis with a mean vector (± 95% confidence interval) of 352°± 2.2, where 0/360° indicates the position of the light source. A study of three strains (UTEX 1688, CCMP 1326, and MBL07) of K. foliaceum showed that the eyespot in two of these strains has degenerated following decades in culture. Thus, previous studies have failed to report positive phototaxis due to loss of directionality caused by the degenerated eyespot. The results are discussed in a broader context and we conclude that studies on algal morphology and physiology may result in erroneous conclusions if based on algal cultures maintained under laboratory conditions for extended periods. © 2013 The Author(s) Journal of Eukaryotic Microbiology © 2013 International Society of Protistologists.

  8. Phototaxis and polarotaxis hand in hand: night dispersal flight of aquatic insects distracted synergistically by light intensity and reflection polarization

    Science.gov (United States)

    Boda, Pál; Horváth, Gábor; Kriska, György; Blahó, Miklós; Csabai, Zoltán

    2014-05-01

    Based on an earlier observation in the field, we hypothesized that light intensity and horizontally polarized reflected light may strongly influence the flight behaviour of night-active aquatic insects. We assumed that phototaxis and polarotaxis together have a more harmful effect on the dispersal flight of these insects than they would have separately. We tested this hypothesis in a multiple-choice field experiment using horizontal test surfaces laid on the ground. We offered simultaneously the following visual stimuli for aerial aquatic insects: (1) lamplit matte black canvas inducing phototaxis alone, (2) unlit shiny black plastic sheet eliciting polarotaxis alone, (3) lamplit shiny black plastic sheet inducing simultaneously phototaxis and polarotaxis, and (4) unlit matte black canvas as a visually unattractive control. The unlit matte black canvas trapped only a negligible number (13) of water insects. The sum (16,432) of the total numbers of water beetles and bugs captured on the lamplit matte black canvas (7,922) and the unlit shiny black plastic sheet (8,510) was much smaller than the total catch (29,682) caught on the lamplit shiny black plastic sheet. This provides experimental evidence for the synergistic interaction of phototaxis (elicited by the unpolarized direct lamplight) and polarotaxis (induced by the strongly and horizontally polarized plastic-reflected light) in the investigated aquatic insects. Thus, horizontally polarizing artificial lamplit surfaces can function as an effective ecological trap due to this synergism of optical cues, especially in the urban environment.

  9. Effects of atmospheric pressure trends on calling, mate-seeking, and phototaxis of Diaphorina citri (Hemiptera: Liviidae)

    Science.gov (United States)

    Insects and other animals sometimes modify behavior in response to changes in atmospheric pressure, an environmental cue that can provide warning of potentially injurious windy and rainy weather. To determine if Diaphorina citri (Hemiptera: Liviidae) calling, mate-seeking, and phototaxis behaviors w...

  10. Reliable inverter systems

    Science.gov (United States)

    Nagano, S.

    1979-01-01

    Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.

  11. Design and Implementation of nine level multilevel Inverter

    Science.gov (United States)

    Dhineshkumar, K.; Subramani, C.

    2018-04-01

    In this paper the solar based boost converter integrated Nine level multilevel inverter presented. It uses 7 switches to produce nine level output stepped waveform. The aim of the work to produce 9 level wave form using solar and boost converter. The conventional inverter has multiple sources and has 16 switches are required and also more number of voltage sources required. The proposed inverter required single solar panel and reduced number of switches and integrated boost converter which increase the input voltage of the inverter. The proposed inverter simulated and compared with R load using Mat lab and prototype model experimentally verified. The proposed inverter can be used in n number of solar applications.

  12. How 5000 independent rowers coordinate their strokes in order to row into the sunlight: Phototaxis in the multicellular green alga Volvox

    Directory of Open Access Journals (Sweden)

    Matsunaga Shigeru

    2010-07-01

    Full Text Available Abstract Background The evolution of multicellular motile organisms from unicellular ancestors required the utilization of previously evolved tactic behavior in a multicellular context. Volvocine green algae are uniquely suited for studying tactic responses during the transition to multicellularity because they range in complexity from unicellular to multicellular genera. Phototactic responses are essential for these flagellates because they need to orientate themselves to receive sufficient light for photosynthesis, but how does a multicellular organism accomplish phototaxis without any known direct communication among cells? Several aspects of the photoresponse have previously been analyzed in volvocine algae, particularly in the unicellular alga Chlamydomonas. Results In this study, the phototactic behavior in the spheroidal, multicellular volvocine green alga Volvox rousseletii (Volvocales, Chlorophyta was analyzed. In response to light stimuli, not only did the flagella waveform and beat frequency change, but the effective stroke was reversed. Moreover, there was a photoresponse gradient from the anterior to the posterior pole of the spheroid, and only cells of the anterior hemisphere showed an effective response. The latter caused a reverse of the fluid flow that was confined to the anterior hemisphere. The responsiveness to light is consistent with an anterior-to-posterior size gradient of eyespots. At the posterior pole, the eyespots are tiny or absent, making the corresponding cells appear to be blind. Pulsed light stimulation of an immobilized spheroid was used to simulate the light fluctuation experienced by a rotating spheroid during phototaxis. The results demonstrated that in free-swimming spheroids, only those cells of the anterior hemisphere that face toward the light source reverse the beating direction in the presence of illumination; this behavior results in phototactic turning. Moreover, positive phototaxis is facilitated by

  13. Electrical power inverter having a phase modulated, twin-inverter, high frequency link and an energy storage module

    Science.gov (United States)

    Pitel, I.J.

    1987-02-03

    The present invention provides an electrical power inverter method and apparatus, which includes a high frequency link, for converting DC power into AC power. Generally stated, the apparatus includes a first high frequency module which produces an AC voltage at a first output frequency, and a second high frequency inverter module which produces an AC voltage at a second output frequency that is substantially the same as the first output frequency. The second AC voltage is out of phase with the first AC voltage by a selected angular phase displacement. A mixer mixes the first and second output voltages to produce a high frequency carrier which has a selected base frequency impressed on the sidebands thereof. A rectifier rectifies the carrier, and a filter filters the rectified carrier. An output inverter inverts the filtered carrier to produce an AC line voltage at the selected base frequency. A phase modulator adjusts the relative angular phase displacement between the outputs of the first and second high frequency modules to control the base frequency and magnitude of the AC line voltage. 19 figs.

  14. Electrical power inverter having a phase modulated, twin-inverter, high frequency link and an energy storage module

    Science.gov (United States)

    Pitel, Ira J.

    1987-02-03

    The present invention provides an electrical power inverter method and apparatus, which includes a high frequency link, for converting DC power into AC power. Generally stated, the apparatus includes a first high frequency module which produces an AC voltage at a first output frequency, and a second high frequency inverter module which produces an AC voltage at a second output frequency that is substantially the same as the first output frequency. The second AC voltage is out of phase with the first AC voltage by a selected angular phase displacement. A mixer mixes the first and second output voltages to produce a high frequency carrier which has a selected base frequency impressed on the sidebands thereof. A rectifier rectifies the carrier, and a filter filters the rectified carrier. An output inverter inverts the filtered carrier to produce an AC line voltage at the selected base frequency. A phase modulator adjusts the relative angular phase displacement between the outputs of the first and second high frequency modules to control the base frequency and magnitude of the AC line voltage.

  15. Status and Needs of Power Electronics for Photovoltaic Inverters

    Science.gov (United States)

    Qin, Y. C.; Mohan, N.; West, R.; Bonn, R.

    2002-06-01

    Photovoltaics is the utility connected distributed energy resource (DER) that is in widespread use today. It has one element, the inverter, which is common with all DER sources except rotating generators. The inverter is required to transfer dc energy to ac energy. With all the DER technologies, (solar, wind, fuel cells, and microturbines) the inverter is still an immature product that will result in reliability problems in fielded systems. Today, the PV inverter is a costly and complex component of PV systems that produce ac power. Inverter MTFF (mean time to first failure) is currently unacceptable. Low inverter reliability contributes to unreliable fielded systems and a loss of confidence in renewable technology. The low volume of PV inverters produced restricts the manufacturing to small suppliers without sophisticated research and reliability programs or manufacturing methods. Thus, the present approach to PV inverter supply has low probability of meeting DOE reliability goals.

  16. Co-existence of mucin-producing urothelial-type adenocarcinoma of the prostate and inverted papilloma of the bladder

    Directory of Open Access Journals (Sweden)

    Xiao-Nan Mu

    2017-06-01

    Full Text Available Adenocarcinoma of prostate with mucinous differentiation arising in the male urethra is extremely rare, with only 21 cases reported in the previous literature. A diagnosis of mucin-producing urothelial carcinoma of the prostate is based on the pathology, immunohistochemistry, and clinical examination by excluding the secondary adenocarcinoma of the prostate. We present a case of unexpected mucinous urothelial carcinoma of prostate with co-existing inverted papilloma of bladder in a 57-year-old man. The patient underwent transurethral resection of the prostate (TURP and transurethral resection of a bladder tumour (TUR-Bt, and the pathologic result showed mucinous prostate carcinoma and bladder inverted papilloma. Immunohistological stain was negative for prostate-specific antigen (PSA, prostate-specific acid phosphatase (PSAP, and P63, but positive for cytokeratin 7 (CK 7, CK 20, clone 34E12 and P504S. A complete endoscopic examination was performed to exclude the secondary adenocarcinoma of prostate. This case illustrates the clinical and pathological features of a rare and unexpected mucin-producing urothelial carcinoma of prostate in a bladder neoplasm patient.

  17. Trans-Z-source Neutral Point Clamped inverter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P. C.; Li, D.

    2012-01-01

    Transformer based Z-source (trans-Z-source) inverters are recently proposed by extending the traditional Z-source inverter with higher buck-boost capability as well as reducing the passive components at the same time. Multi-Level Z-source inverters are single-stage topological solutions used...... for buck-boost energy conversion with all the favourable advantages of multi-level switching retained. This paper presents three-level trans-Z-source Neutral Point Clamped (NPC) inverter topology, which achieves both the advantages of trans-Z-source and three-level NPC inverter configuration. With proper...... modulation scheme, the three-level trans-Z-source inverter can function with minimum of six device commutations per half carrier cycle (same as the traditional buck NPC inverter), while maintaining to produce the designed volt-sec average and inductive voltage boosting at ac output terminals. The designed...

  18. Nanowire NMOS Logic Inverter Characterization.

    Science.gov (United States)

    Hashim, Yasir

    2016-06-01

    This study is the first to demonstrate characteristics optimization of nanowire N-Channel Metal Oxide Semiconductor (NW-MOS) logic inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. A computer-based model used to produce static characteristics of NW-NMOS logic inverter. In this research two circuit configuration of NW-NMOS inverter was studied, in first NW-NMOS circuit, the noise margin for (low input-high output) condition was very low. For second NMOS circuit gives excellent noise margins, and results indicate that optimization depends on applied voltage to the inverter. Increasing gate to source voltage with (2/1) nanowires ratio results better noise margins. Increasing of applied DC load transistor voltage tends to increasing in decreasing noise margins; decreasing this voltage will improve noise margins significantly.

  19. Genetic analysis reveals the identity of the photoreceptor for phototaxis in hormogonium filaments of Nostoc punctiforme.

    Science.gov (United States)

    Campbell, Elsie L; Hagen, Kari D; Chen, Rui; Risser, Douglas D; Ferreira, Daniela P; Meeks, John C

    2015-02-15

    In cyanobacterial Nostoc species, substratum-dependent gliding motility is confined to specialized nongrowing filaments called hormogonia, which differentiate from vegetative filaments as part of a conditional life cycle and function as dispersal units. Here we confirm that Nostoc punctiforme hormogonia are positively phototactic to white light over a wide range of intensities. N. punctiforme contains two gene clusters (clusters 2 and 2i), each of which encodes modular cyanobacteriochrome-methyl-accepting chemotaxis proteins (MCPs) and other proteins that putatively constitute a basic chemotaxis-like signal transduction complex. Transcriptional analysis established that all genes in clusters 2 and 2i, plus two additional clusters (clusters 1 and 3) with genes encoding MCPs lacking cyanobacteriochrome sensory domains, are upregulated during the differentiation of hormogonia. Mutational analysis determined that only genes in cluster 2i are essential for positive phototaxis in N. punctiforme hormogonia; here these genes are designated ptx (for phototaxis) genes. The cluster is unusual in containing complete or partial duplicates of genes encoding proteins homologous to the well-described chemotaxis elements CheY, CheW, MCP, and CheA. The cyanobacteriochrome-MCP gene (ptxD) lacks transmembrane domains and has 7 potential binding sites for bilins. The transcriptional start site of the ptx genes does not resemble a sigma 70 consensus recognition sequence; moreover, it is upstream of two genes encoding gas vesicle proteins (gvpA and gvpC), which also are expressed only in the hormogonium filaments of N. punctiforme. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Transformerless PV inverters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Borup, U.

    2009-12-15

    Since the start of the project the market for grid connected PV inverters have developed further. When the project started three - phase inverter were only available in high power systems. The technology developed within this project will enable three phase technology also to be implemented in string inverters for system down to 10 kW. We expect this to be very attractive due to the increased demand for symmetrical feed-in to the grid. The project relevance is therefore high and the sector continues to develop very much driven by technology. Especially the inverter technology is getting a lot of focus. The inverter systems are expected to take a much larger role in supporting the electrical grid in the future. The technology platform developed within the project is prepared to be extended with these utility functionalities. The main results of the project were: 1) A new technology concept for transformer-less inverters has been demonstrated with a number of prototypes. 2) Efficiency above 97,7% has been proven. 3) Efficiency and Maximum power point tracking has been optimized to ensure that almost all energy produced of the panels is transferred to the grid. 4) The platform is developed with a very fast control board, which enables extended functionality as demanding grid supporting functions in the future. Details about cost price and details about the control loop implementation is excluded from the report due to the competitive situation for Danfoss Solar Inverters A/S. (LN)

  1. Sensory rhodopsins I and II modulate a methylation/demethylation system in Halobacterium halobium phototaxis

    International Nuclear Information System (INIS)

    Spudich, E.N.; Takahashi, T.; Spudich, J.L.

    1989-01-01

    This work demonstrates that phototaxis stimuli in the archaebacterium Halobacterium halobium control a methylation/demethylation system in vivo through photoactivation of sensory rhodopsin I (SR-I) in either its attractant or repellent signaling form as well as through the repellent receptor sensory rhodopsin II (SR-II, also called phoborhodopsin). The effects of positive stimuli that suppress swimming reversals (i.e., an increase in attractant or decrease in repellent light) and negative stimuli that induce swimming reversals (i.e., a decrease in attractant or increase in repellent light) through each photoreceptor were monitored by assaying release of volatile [3H]methyl groups. This assay has been used to measure [3H]methanol produced during the process of adaptation to chemotactic stimuli in eubacteria. In H. halobium positive photostimuli produce a transient increase in the rate of demethylation followed by a decrease below the unstimulated value, whereas negative photostimuli cause an increase followed by a rate similar to that of the unstimulated value. Photoactivation of the SR-I attractant and simultaneous photoactivation of the SR-II repellent receptors cancel in their effects on demethylation, demonstrating the methylation system is regulated by an integrated signal. Analysis of mutants indicates that the source for the volatile methyl groups is intrinsic membrane proteins distinct from the chromoproteins that share the membrane. A methyl-accepting protein (94 kDa) previously correlated in amount with the SR-I chromoprotein (25 kDa) is shown here to be missing in a recently isolated SR-I-SR-II+ mutant (Flx3b), thus confirming the association of this protein with SR-I. Photoactivated SR-II in mutant Flx3b controls demethylation, predicting the existence of a photomodulated methyl-accepting component distinct from the 94-kDa protein of SR-I

  2. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters.

    Science.gov (United States)

    Algaddafi, Ali; Altuwayjiri, Saud A; Ahmed, Oday A; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.

  3. Inverters for photovoltaics: quality assurance

    International Nuclear Information System (INIS)

    Graf, J.D.; Haeberlin, H.

    2000-01-01

    This project-overview published by the University of Applied Science in Burgdorf, Switzerland, looks back at the history of the university's testing laboratory for inverters for use in photovoltaic installations and discusses the work done there. After its move from Oberburg to Burgdorf in the early nineties, the laboratory was equipped to provide testing facilities for inverters up to 60 kW. Additions have been made to the infrastructure since then to facilitate the testing of various types of inverter produced in Switzerland and other countries. The measurements that can be carried out, including DC-AC conversion efficiency, harmonics, RF interference, islanding, sensitivity to tele-control signals, turn-on power and operating voltage range are described. The improvement in the quality of the inverters tested is discussed and the importance of continued testing as new manufacturers come onto the market is emphasised. The installation of further testing equipment, such as a 25 kW solar generator simulator and apparatus for the testing of maximum-power-tracking efficiency is discussed

  4. Diode-Assisted Buck-Boost Voltage-Source Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    , a number of diode-assisted inverter variants can be designed with each having its own operational principle and voltage gain expression. For controlling them, a generic modulation scheme that can be used for controlling all diode-assisted variants with minimized harmonic distortion and component stress......This paper proposes a number of diode-assisted buck-boost voltage-source inverters with a unique X-shaped diode-capacitor network inserted between the inverter circuitry and dc source for producing a voltage gain that is comparatively higher than those of other buck-boost conversion techniques....... Using the diode-assisted network, the proposed inverters can naturally configure themselves to perform capacitive charging in parallel and discharging in series to give a higher voltage multiplication factor without compromising waveform quality. In addition, by adopting different front-end circuitries...

  5. A single-phase embedded Z-source DC-AC inverter.

    Science.gov (United States)

    Kim, Se-Jin; Lim, Young-Cheol

    2014-01-01

    In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively.

  6. Inverter for Interchangeable Use as Current Source Inverter and Voltage Source Inverter for Interconnecting to Grid

    Science.gov (United States)

    Teruya, Daisuke; Masukawa, Shigeo; Iida, Shoji

    We propose a novel inverter that can be operated either as a Current Source Inverter (CSI) or as a Voltage Source Inverter (VSI) by changing only the control signals. It is proper to apply it to the interconnecting system with renewal energy, such as photovoltaic cells or wind generation systems, to a grid. This inverter is usually operated as the CSI connected to the grid. Even if the energy source has a lower voltage than the grid, the energy can be supplied to the grid through the proposed inverter. The power factor can be briefly maintained at almost unity. When power supply from the grid is interrupted, the proposed circuit should be operated as the VSI in the stand-alone operation mode. In this way, the circuit can maintain a constant output voltage to the loads. In this paper, the proposed circuit configuration and the control schemes for both the CSI and the VSI are described. Further, the circuit characteristics for both are discussed experimentally.

  7. State-space-based harmonic stability analysis for paralleled grid-connected inverters

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2016-01-01

    This paper addresses a state-space-based harmonic stability analysis of paralleled grid-connected inverters system. A small signal model of individual inverter is developed, where LCL filter, the equivalent delay of control system, and current controller are modeled. Then, the overall small signal...... model of paralleled grid-connected inverters is built. Finally, the state space-based stability analysis approach is developed to explain the harmonic resonance phenomenon. The eigenvalue traces associated with time delay and coupled grid impedance are obtained, which accounts for how the unstable...... inverter produces the harmonic resonance and leads to the instability of whole paralleled system. The proposed approach reveals the contributions of the grid impedance as well as the coupled effect on other grid-connected inverters under different grid conditions. Simulation and experimental results...

  8. Migratory bats respond to artificial green light with positive phototaxis.

    Directory of Open Access Journals (Sweden)

    Christian C Voigt

    Full Text Available Artificial light at night is spreading worldwide at unprecedented rates, exposing strictly nocturnal animals such as bats to a novel anthropogenic stressor. Previous studies about the effect of artificial light on bats focused almost exclusively on non-migratory species, yet migratory animals such as birds are known to be largely affected by light pollution. Thus, we conducted a field experiment to evaluate if bat migration is affected by artificial light at night. In late summer, we presented artificial green light of 520 nm wavelength to bats that were migrating south along the shoreline of the Baltic Sea. Using a light on-off treatment, we observed that the activity of Pipistrellus nathusii and P. pygmaeus, the two most abundant migratory species at our site, increased by more than 50% in the light-on compared to the light-off treatment. We observed an increased number of feeding buzzes during the light-on compared to the light-off treatment for P. nathusii. However, feeding activity was low in general and did not increase disproportionately during the light-on treatment in relation to the overall echolocation call activity of bats. Further, P. nathusii were attracted towards the green light at a distance of about 23 m, which is way beyond the echolocation detection range for insects of Nathusius' bats. We therefore infer that migratory bats were not attracted to artificial green light because of high insect densities, but instead by positive phototaxis. We conclude that artificial light at night may potentially impact bat migration in a yet unrecognized way.

  9. Y-source inverter

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Town, Graham; Loh, Poh Chiang

    2014-01-01

    This paper introduces a new 3-phase Y-source inverter whose gain is presently not matched by classical impedance-network-based inverters operating at the same duty ratio. The proposed network uses a tightly coupled transformer with three windings. By squeezing the shoot-through range while keeping...... higher boost, the inverter can operate at a higher modulation index, thereby minimizing switching device stress and providing better output power quality. In addition, the inverter has more degrees of freedom for setting the voltage gain and modulation index than other classical impedance-source networks...

  10. Development and Evaluation of a 2KVA Inverter

    Directory of Open Access Journals (Sweden)

    Ajayi Adedayo

    2013-09-01

    Full Text Available A 2KV inverter was designed, developed and tested for household applications. It consists of a heavy duty (24 V, 80 AH, oscillator unit, PWM (Pulse-width modulation controller unit, driver unit, amplifier unit, center-tap step up transformer and battery charger unit. The battery powered the circuitry and the oscillator section generates the drive signal that is amplified and set up the transformer to produce 240 V supply at the secondary winding connected to the output socket of inverter. The feedback control circuit uses discrete components such as: full wave rectifier, pulse width modulator (IC, diodes and other components to sense the output voltage (or load current. When the feedback senses that the load on the inverter output has increased, the inverter control circuitry acts by increasing the width of the switching pulse in the oscillator section which turn on the MOSFETS. MOSFETS turns on for longer time each cycle, automatically correcting the R.M.S value of the output to compensate for any drop in peak-peak output voltage as well as continuous charging of battery, consequently, maintaining a steady output voltage level in inverter irrespective of the load characteristics. The outputs of the tests carried on the unit shows that that instrument performs satisfactory well.

  11. Closed Loop Fuzzy Logic Controlled PV Based Cascaded Boost Five-Level Inverter System

    Science.gov (United States)

    Revana, Guruswamy; Kota, Venkata Reddy

    2018-04-01

    Recent developments in intelligent control methods and power electronics have produced PV based DC to AC converters related to AC drives. Cascaded boost converter and inverter find their way in interconnecting PV and Induction Motor. This paper deals with digital simulation and implementation of closed loop controlled five-level inverter based Photo-Voltaic (PV) system. The objective of this work is to reduce the harmonics using Multi Level Inverter based system. The DC output from the PV panel is boosted using cascaded-boost-converters. The DC output of these cascaded boost converters is applied to the bridges of the cascaded inverter. The AC output voltage is obtained by the series cascading of the output voltage of the two inverters. The investigations are done with Induction motor load. Cascaded boost-converter is proposed in the present work to produce the required DC Voltage at the input of the bridge inverter. A simple FLC is applied to CBFLIIM system. The FLC is proposed to reduce the steady state error. The simulation results are compared with the hardware results. The results of the comparison are made to show the improvement in dynamic response in terms of settling time and steady state error. Design procedure and control strategy are presented in detail.

  12. Inverted oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Yuce, C [Physics Department, Anadolu University, Eskisehir (Turkey); Kilic, A [Physics Department, Anadolu University, Eskisehir (Turkey); Coruh, A [Physics Department, Sakarya University, Sakarya (Turkey)

    2006-07-15

    The inverted harmonic oscillator problem is investigated quantum mechanically. The exact wavefunction for the confined inverted oscillator is obtained and it is shown that the associated energy eigenvalues are discrete, and the energy is given as a linear function of the quantum number n.

  13. Modular inverter system

    Science.gov (United States)

    Ma, Mingyao; Hu, Haibing; Kutkut, Nasser; Batarseh, Issa; Shen, John; , Bkayrat, Raed

    2017-08-01

    A system connected to an AC power grid having an AC phase signal includes an inverter module including a first inverter coupled to a DC voltage, actuated based on the AC phase signal. The first inverter provides a first voltage signal having predetermined harmonic components. A second inverter includes second switch elements coupled to the DC voltage and actuated by a second set of control signals phase delayed with respect to the first control signals. A transformer module has first and second primary windings coupled to the first and second inverters. The transformer module further includes a secondary winding coupled to first primary winding, the second primary winding, and the AC power grid. The secondary winding is configured to provide a secondary output voltage to the AC power grid by combining the first voltage signal and the second voltage signal such that the predetermined harmonic components are substantially cancelled.

  14. Performance analysis of new type grid-tied inverter-Aalborg Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Wang, Zhen; Ji, Junhao

    2014-01-01

    Aalborg Inverter is a grid-tied DC/AC inverter. In order to optimize the design, its power losses are analyzed in detail, combined with a description of the single-phase operating principle and the modulation strategy. A 2 kW / 220 V experimental prototype is constructed to verify the theoretical...... analysis. It is concluded that a minimize inductance in the power loop does help the inverter to achieve the high efficiency with the good dynamic performance....

  15. Modified Dual Three-Pulse Modulation technique for single-phase inverter topology

    Science.gov (United States)

    Sree Harsha, N. R.; Anitha, G. S.; Sreedevi, A.

    2016-01-01

    In a recent paper, a new modulation technique called Dual Three Pulse Modulation (DTPM) was proposed to improve the efficiency of the power converters of the Electric/Hybrid/Fuel-cell vehicles. It was simulated in PSIM 9.0.4 and uses analog multiplexers to generate the modulating signals for the DC/DC converter and inverter. The circuit used is complex and many other simulation softwares do not support the analog multiplexers as well. Also, the DTPM technique produces modulating signals for the converter, which are essentially needed to produce the modulating signals for the inverter. Hence, it cannot be used efficiently to switch the valves of a stand-alone inverter. We propose a new method to generate the modulating signals to switch MOSFETs of a single phase Dual-Three pulse Modulation based stand-alone inverter. The circuits proposed are simulated in Multisim 12.0. We also show an alternate way to switch a DC/DC converter in a way depicted by DTPM technique both in simulation (MATLAB/Simulink) and hardware. The circuitry is relatively simple and can be used for the further investigations of DTPM technique.

  16. Quasi-Y-source inverter

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    This paper introduces a new inverter topology called a “quasi-Y-source inverter”. The proposed inverter inherits all the advantages of the original Y-source inverter. In addition, the new topology draws continuous current from the source which is required for many renewable sources. It also has dc......-current-blocking capacitors, which avoids saturation in the transformer core. Simulations and experimental results have proved the validity of the proposed inverter....

  17. Selective Harmonic Elimination in Asymmetric Cascaded Multilevel Inverters Using a New Low-frequency Strategy for Photovoltaic Applications

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Iman-Eini, Hossein; Blaabjerg, Frede

    2015-01-01

    Asymmetric multilevel inverters with a main and auxiliary power circuit can yield maximum number of voltage levels against the number of semiconductor devices. Most of the output power will be produced by the main inverter, which works at low frequency and the auxiliary inverters only improve the...

  18. Properties of the Visible Light Phototaxis and UV Avoidance Behaviors in the Larval Zebrafish.

    Science.gov (United States)

    Guggiana-Nilo, Drago A; Engert, Florian

    2016-01-01

    For many organisms, color is an essential source of information from visual scenes. The larval zebrafish has the potential to be a model for the study of this topic, given its tetrachromatic retina and high dependence on vision. In this study we took a step toward understanding how the larval zebrafish might use color sensing. To this end, we used a projector-based paradigm to force a choice of a color stimulus at every turn of the larva. The stimuli used spanned most of the larval spectral range, including activation of its Ultraviolet (UV) cone, which has not been described behaviorally before. We found that zebrafish larvae swim toward visible wavelengths (>400 nm) when choosing between them and darkness, as has been reported with white light. However, when presented with UV light and darkness zebrafish show an intensity dependent avoidance behavior. This UV avoidance does not interact cooperatively with phototaxis toward longer wavelengths, but can compete against it in an intensity dependent manner. Finally, we show that the avoidance behavior depends on the presence of eyes with functional UV cones. These findings open future avenues for studying the neural circuits that underlie color sensing in the larval zebrafish.

  19. A Comparison Study of Sinusoidal PWM and Space Vector PWM Techniques for Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Ömer Türksoy

    2017-06-01

    Full Text Available In this paper, the methods used to control voltage source inverters which have been intensively investigated in recent years are compared. Although the most efficient result is obtained with the least number of switching elements in the inverter topologies, the method used in the switching is at least as effective as the topology. Besides, the selected switching method to control the inverter will play an effective role in suppressing harmonic components while producing the ideal output voltage. There are many derivatives of pulse width modulation techniques that are commonly used to control voltage source inverters. Some of widespread methods are sinusoidal pulse width modulation and space vector pulse width modulation techniques. These modulation techniques used for generating variable frequency and amplitude output voltage in voltage source inverters, have been simulated by using MATLAB/SIMULINK. And, the total harmonic distortions of the output voltages are compared. As a result of simulation studies, sinusoidal pulse width modulation has been found to have more total harmonic distortion in output voltages of voltage source inverters in the simulation. Space vector pulse width modulation has been shown to produce a more efficient output voltage with less total harmonic distortion.

  20. Origin-Dependent Inverted-Repeat Amplification: Tests of a Model for Inverted DNA Amplification.

    Directory of Open Access Journals (Sweden)

    Bonita J Brewer

    2015-12-01

    Full Text Available DNA replication errors are a major driver of evolution--from single nucleotide polymorphisms to large-scale copy number variations (CNVs. Here we test a specific replication-based model to explain the generation of interstitial, inverted triplications. While no genetic information is lost, the novel inversion junctions and increased copy number of the included sequences create the potential for adaptive phenotypes. The model--Origin-Dependent Inverted-Repeat Amplification (ODIRA-proposes that a replication error at pre-existing short, interrupted, inverted repeats in genomic sequences generates an extrachromosomal, inverted dimeric, autonomously replicating intermediate; subsequent genomic integration of the dimer yields this class of CNV without loss of distal chromosomal sequences. We used a combination of in vitro and in vivo approaches to test the feasibility of the proposed replication error and its downstream consequences on chromosome structure in the yeast Saccharomyces cerevisiae. We show that the proposed replication error-the ligation of leading and lagging nascent strands to create "closed" forks-can occur in vitro at short, interrupted inverted repeats. The removal of molecules with two closed forks results in a hairpin-capped linear duplex that we show replicates in vivo to create an inverted, dimeric plasmid that subsequently integrates into the genome by homologous recombination, creating an inverted triplication. While other models have been proposed to explain inverted triplications and their derivatives, our model can also explain the generation of human, de novo, inverted amplicons that have a 2:1 mixture of sequences from both homologues of a single parent--a feature readily explained by a plasmid intermediate that arises from one homologue and integrates into the other homologue prior to meiosis. Our tests of key features of ODIRA lend support to this mechanism and suggest further avenues of enquiry to unravel the origins

  1. Origin-Dependent Inverted-Repeat Amplification: Tests of a Model for Inverted DNA Amplification.

    Science.gov (United States)

    Brewer, Bonita J; Payen, Celia; Di Rienzi, Sara C; Higgins, Megan M; Ong, Giang; Dunham, Maitreya J; Raghuraman, M K

    2015-12-01

    DNA replication errors are a major driver of evolution--from single nucleotide polymorphisms to large-scale copy number variations (CNVs). Here we test a specific replication-based model to explain the generation of interstitial, inverted triplications. While no genetic information is lost, the novel inversion junctions and increased copy number of the included sequences create the potential for adaptive phenotypes. The model--Origin-Dependent Inverted-Repeat Amplification (ODIRA)-proposes that a replication error at pre-existing short, interrupted, inverted repeats in genomic sequences generates an extrachromosomal, inverted dimeric, autonomously replicating intermediate; subsequent genomic integration of the dimer yields this class of CNV without loss of distal chromosomal sequences. We used a combination of in vitro and in vivo approaches to test the feasibility of the proposed replication error and its downstream consequences on chromosome structure in the yeast Saccharomyces cerevisiae. We show that the proposed replication error-the ligation of leading and lagging nascent strands to create "closed" forks-can occur in vitro at short, interrupted inverted repeats. The removal of molecules with two closed forks results in a hairpin-capped linear duplex that we show replicates in vivo to create an inverted, dimeric plasmid that subsequently integrates into the genome by homologous recombination, creating an inverted triplication. While other models have been proposed to explain inverted triplications and their derivatives, our model can also explain the generation of human, de novo, inverted amplicons that have a 2:1 mixture of sequences from both homologues of a single parent--a feature readily explained by a plasmid intermediate that arises from one homologue and integrates into the other homologue prior to meiosis. Our tests of key features of ODIRA lend support to this mechanism and suggest further avenues of enquiry to unravel the origins of interstitial

  2. Fault-tolerant three-level inverter

    Science.gov (United States)

    Edwards, John; Xu, Longya; Bhargava, Brij B.

    2006-12-05

    A method for driving a neutral point clamped three-level inverter is provided. In one exemplary embodiment, DC current is received at a neutral point-clamped three-level inverter. The inverter has a plurality of nodes including first, second and third output nodes. The inverter also has a plurality of switches. Faults are checked for in the inverter and predetermined switches are automatically activated responsive to a detected fault such that three-phase electrical power is provided at the output nodes.

  3. Arduino Mega 2560 Microcontroller Built 3-Phase Seven Level Inverter

    Directory of Open Access Journals (Sweden)

    PAVANKUMAR Shriram Mehtre

    2017-10-01

    Full Text Available n this paper, the implementation of 3-phase seven level cascaded H-bridge inverter is discussed with Arduino microcontroller and harmonic analysis is performed using Fourier series. The multilevel inverters (MLI give several benefits as reduced switching voltage stresses and the capability to operate in higher level voltage applications. A new and simple architecture Arduino Mega 2560 microcontroller is employed to produce the control signals for the seven level cascaded H-bridge MLI switches. The computer simulation is carried out in PSIM environment and prototype experimental model is developed with TLP 250 driver ICs and power MOSFET switches to validate the simulation results. The THDs present in different voltage level inverters are mathematically analysed using Fourier series.

  4. Analisis Harmonisa Inverter PWM Satu Fasa

    OpenAIRE

    Rejeki Simanjorang

    2008-01-01

    Pada tesis ini dianalisis harmonisa inverter PWM satu fasa. Inverter PWM satu fasa yang akan ditinjau adalah inverter satu fasa jembatan penuh (konvensional) dan inverter komposit. Analisis difokuskan pada penentuan pola penyaklaran yang optimum agar pembangkitan harmonisa dan switching losses inverter rendah. Untuk menentukan pola penyaklaran optimum maka dilakukan analisis yang berbasis pada rangkaian ekivalen harmonisa inverter satu fasa. Dengan menggunakan pola penyaklaran optimum, kedua ...

  5. 2015 Inverter Workshop | Photovoltaic Research | NREL

    Science.gov (United States)

    Inverter Workshop 2015 Inverter Workshop Wednesday, February 25, 2015 Chair: Jack Flicker In about inverters. This workshop represented a follow-on to the inverter workshops that Sandia National conversations between module and inverter experts. Agenda For a detailed schedule of the day's events, access

  6. Factorization method and new potentials from the inverted oscillator

    International Nuclear Information System (INIS)

    Bermudez, David; Fernández C, David J.

    2013-01-01

    In this article we will apply the first- and second-order supersymmetric quantum mechanics to obtain new exactly-solvable real potentials departing from the inverted oscillator potential. This system has some special properties; in particular, only very specific second-order transformations produce non-singular real potentials. It will be shown that these transformations turn out to be the so-called complex ones. Moreover, we will study the factorization method applied to the inverted oscillator and the algebraic structure of the new Hamiltonians. -- Highlights: •We apply supersymmetric quantum mechanics to the inverted oscillator potential. •The complex second-order transformations allow us to build new non-singular potentials. •The algebraic structure of the initial and final potentials is analyzed. •The initial potential is described by a complex-deformed Heisenberg–Weyl algebra. •The final potentials are described by polynomial Heisenberg algebras

  7. Milliwatt dc/dc Inverter

    Science.gov (United States)

    Mclyman, C. W.

    1983-01-01

    Compact dc/dc inverter uses single integrated-circuit package containing six inverter gates that generate and amplify 100-kHz square-wave switching signal. Square-wave switching inverts 10-volt local power to isolated voltage at another desired level. Relatively high operating frequency reduces size of filter capacitors required, resulting in small package unit.

  8. A novel circuit topology of modified switched boost hybrid resonant inverter fitted induction heating equipment

    Directory of Open Access Journals (Sweden)

    Bhattacharya Ananyo

    2016-12-01

    Full Text Available A novel circuit topology of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment is presented in this paper for efficient induction heating. Recently, induction heating technique is becoming very popular for both domestic and industrial purposes because of its high energy efficiency and controllability. Generally in induction heating, a high frequency alternating magnetic field is required to induce the eddy currents in the work piece. High frequency resonant inverters are incorporated in induction heating equipment which produce a high frequency alternating magnetic field surrounding the coil. Previously this high frequency alternating magnetic field was produced by voltage source inverters. But VSIs have several demerits. So, in this paper, a new scheme of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment has been depicted which enhances the energy efficiency and controllability and the same is validated by PSIM.

  9. Overload protection system for power inverter

    Science.gov (United States)

    Nagano, S. (Inventor)

    1977-01-01

    An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

  10. Large-Signal Lyapunov-Based Stability Analysis of DC/AC Inverters and Inverter-Based Microgrids

    Science.gov (United States)

    Kabalan, Mahmoud

    study. This will enable future studies to save computational effort and produce the most accurate results according to the needs of the study being performed. Moreover, the effect of grid (line) impedance on the accuracy of droop control is explored using the 5th order model. Simulation results show that traditional droop control is valid up to R/X line impedance value of 2. Furthermore, the 3rd order nonlinear model improves the currently available inverter-infinite bus models by accounting for grid impedance, active power-frequency droop and reactive power-voltage droop. Results show the 3rd order model's ability to account for voltage and reactive power changes during a transient event. Finally, the large-signal Lyapunov-based stability analysis is completed for a 3 bus microgrid system (made up of 2 inverters and 1 linear load). The thesis provides a systematic state space large-signal nonlinear mathematical modeling method of inverter-based microgrids. The inverters include the dc-side dynamics associated with dc sources. The mathematical model is then used to estimate the domain of asymptotic stability of the 3 bus microgrid. The three bus microgrid system was used as a case study to highlight the design and optimization capability of a large-signal-based approach. The study explores the effect of system component sizing, load transient and generation variations on the asymptotic stability of the microgrid. Essentially, this advancement gives microgrid designers and engineers the ability to manipulate the domain of asymptotic stability depending on performance requirements. Especially important, this research was able to couple the domain of asymptotic stability of the ac microgrid with that of the dc side voltage source. Time domain simulations were used to demonstrate the mathematical nonlinear analysis results.

  11. Hybrid PV/wind system with quinary asymmetric inverter without increasing DC-link number

    Directory of Open Access Journals (Sweden)

    Aida Baghbany Oskouei

    2016-06-01

    Full Text Available This paper suggests quinary asymmetric inverter with coupled inductors and transformer, and uses it in hybrid system including photovoltaic (PV and wind. This inverter produces twenty-five-level voltage in addition to merits of multilevel inverter, has only one DC source. Then, it is adequate for hybrid systems, which prevents increasing DC-link and makes control of system easy. Proposed structure also provides isolation in the system and the switch numbers are reduced in this topology compared with other multilevel structures. In this system, battery is used as backup, where PV and wind have complementary nature. The performance of proposed inverter and hybrid system is validated with simulation results using MATLAB/SIMULINK software and experimental results based PCI-1716 data acquisition system.

  12. Three-Phase Cascaded Multilevel Inverter Using Power Cells With Two Inverter Legs in Series

    NARCIS (Netherlands)

    Waltrich, G.; Barbi, I.

    2010-01-01

    In this paper, a modular three-phase multilevel inverter specially suited for electrical drive applications is proposed. Unlike the cascaded H-bridge inverter, this topology is based on power cells connected in cascade using two inverter legs in series. A detailed analysis of the structure and the

  13. Γ-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    Transformer based Z-source inverters are recently proposed to achieve promising buck-boost capability. They have improved higher buck-boost capability, smaller size and less components count over Z-source inverters. On the other hand, neutral point clamped inverters have less switching stress...... and better output performance comparing with traditional two-level inverters. Integrating these two types of configurations can help neutral point inverters achieve enhanced votlage buck-boost capability....

  14. SEEPAGE/INVERT INTERACTIONS

    International Nuclear Information System (INIS)

    P.S. Domski

    2000-01-01

    As directed by a written development plan (CRWMS M andO 1999a), a conceptual model for water entering the drift and reacting with the invert materials is to be developed. The purpose of this conceptual model is to assist Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department in modeling the geochemical environment within a repository drift, thus allowing PAO to provide a more detailed and complete in-drift geochemical model abstraction, and to answer the key technical issues (KTI) raised in the NRC Issue Resolution Status Report (IRSR) for the Evolution of the Near-Field Environment (NFE), Revision 2 (NRC 1999). This AMR also seeks to: (1) Develop a logical conceptual model for physical/chemical interactions between seepage and the invert materials; (2) screen potential processes and reactions that may occur between seepage and invert to evaluate the potential consequences of the interactions; and (3) outline how seepage/invert processes may be quantified. This document provides the conceptual framework for screening out insignificant processes and for identifying and evaluating those seepage/invert interactions that have the potential to be important to subsequent PAO analyses including the Engineered Barrier System (EBS) physical and chemical model abstraction effort. This model has been developed to serve as a basis for the in-drift geochemical analyses performed by PAO. Additionally, the concepts discussed within this report may also apply to certain near and far-field geochemical processes and may have conceptual application within the unsaturated zone (UZ) and saturated zone (SZ) transport modeling efforts. The seepage/invert interactions will not directly affect any principal factors

  15. Inverter communications using output signal

    Science.gov (United States)

    Chapman, Patrick L.

    2017-02-07

    Technologies for communicating information from an inverter configured for the conversion of direct current (DC) power generated from an alternative source to alternating current (AC) power are disclosed. The technologies include determining information to be transmitted from the inverter over a power line cable connected to the inverter and controlling the operation of an output converter of the inverter as a function of the information to be transmitted to cause the output converter to generate an output waveform having the information modulated thereon.

  16. Multilevel DC link inverter

    Science.gov (United States)

    Su, Gui-Jia

    2003-06-10

    A multilevel DC link inverter and method for improving torque response and current regulation in permanent magnet motors and switched reluctance motors having a low inductance includes a plurality of voltage controlled cells connected in series for applying a resulting dc voltage comprised of one or more incremental dc voltages. The cells are provided with switches for increasing the resulting applied dc voltage as speed and back EMF increase, while limiting the voltage that is applied to the commutation switches to perform PWM or dc voltage stepping functions, so as to limit current ripple in the stator windings below an acceptable level, typically 5%. Several embodiments are disclosed including inverters using IGBT's, inverters using thyristors. All of the inverters are operable in both motoring and regenerating modes.

  17. Development of high-power inverter supply for current drive of FRC plasma

    International Nuclear Information System (INIS)

    Kitano, Katsuhisa; Higashikozono, Takamitsu; Okada, Shigefumi; Goto, Seiichi

    2003-01-01

    High-Power RF supply is developed for the current drive of FRC (Field Reversed Configuration) plasma. The rotating magnetic field is produced by the four antennas set in the parallel direction to the geometrical axis of the FRC and faced each other. The sinusoidal currents with shifted phases by 90 degree each other should be supplied to the antennas. The two power supplies are necessary if a pair of the antennas faced oppositely are connected. Considering the plasma parameters, the rotating field of 50-100kHz and 50G at the center axis is expected to be required. We develop the adequate RF power supply for the purpose. The power supply consists of the inverter circuit, the step-up transformer and the LC tank ciruit. For the switching device of the inverter circuit, the IGBT (Insulated Gate Bipolar Transistor) is adopted. The inverter circuit is full bridge type. To operate it at high voltages, its arm consists of the 3 IGBTs arranged series. The output of the inverter is connected to the tank circuit by way of the step-up transformer with air core. The tank circuit is the parallel circuit of the antenna and the capacitor. By the adjustment of the frequency of the inverter output to the resonance frequency of the tank circuit, the large sinusoidal waveform current is obtained. The developed power supply can produce the current of 5kA at 10kV to the dummy antenna with almost the same inductance of the antenna. (author)

  18. Resonant snubber inverter

    Science.gov (United States)

    Lai, Jih-Sheng; Young, Sr., Robert W.; Chen, Daoshen; Scudiere, Matthew B.; Ott, Jr., George W.; White, Clifford P.; McKeever, John W.

    1997-01-01

    A resonant, snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the main inverter switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.

  19. Harmonic elimination in diode-clamped multilevel inverter using evolutionary algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Barkati, Said [Laboratoire d' analyse des Signaux et Systemes (LASS), Universite de M' sila, BP. 166, rue Ichbilia 28000 M' sila (Algeria); Baghli, Lotfi [Groupe de Recherche en Electrotechnique et Electronique de Nancy (GREEN), CNRS UMR 7030, Universite Henri Poincare Nancy 1, BP. 239, 54506 Vandoeuvre-les-Nancy (France); Berkouk, El Madjid; Boucherit, Mohamed-Seghir [Laboratoire de Commande des Processus (LCP), Ecole Nationale Polytechnique, BP. 182, 10 Avenue Hassen Badi, 16200 El Harrach, Alger (Algeria)

    2008-10-15

    This paper describes two evolutionary algorithms for the optimized harmonic stepped-waveform technique. Genetic algorithms and particle swarm optimization are applied to compute the switching angles in a three-phase seven-level inverter to produce the required fundamental voltage while, at the same time, specified harmonics are eliminated. Furthermore, these algorithms are also used to solve the starting point problem of the Newton-Raphson conventional method. This combination provides a very effective method for the harmonic elimination technique. This strategy is useful for different structures of seven-level inverters. The diode-clamped topology is considered in this study. (author)

  20. Next Generation Inverter

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Zilai [General Motors LLC, Detroit, MI (United States); Gough, Charles [General Motors LLC, Detroit, MI (United States)

    2016-04-22

    The goal of this Cooperative Agreement was the development of a Next Generation Inverter for General Motors’ electrified vehicles, including battery electric vehicles, range extended electric vehicles, plug-in hybrid electric vehicles and hybrid electric vehicles. The inverter is a critical electronics component that converts battery power (DC) to and from the electric power for the motor (AC).

  1. Inverting the Linear Algebra Classroom

    Science.gov (United States)

    Talbert, Robert

    2014-01-01

    The inverted classroom is a course design model in which students' initial contact with new information takes place outside of class meetings, and students spend class time on high-level sense-making activities. The inverted classroom model is so called because it inverts or "flips" the usual classroom design where typically class…

  2. Analysis of Extended Z-source Inverter for Photovoltaic System

    Science.gov (United States)

    Prakash, G.; Subramani, C.; Dhineshkumar, K.; Rayavel, P.

    2018-04-01

    The Z-source inverter has picked up prominence as a solitary stage buck-support inverter topology among numerous specialists. Notwithstanding, its boosting capacity could be constrained, and in this manner, it may not be reasonable for a few applications requiring high lift request of falling other dc-dc help converters. The Z-source inverter is a recent converter topology that exhibits both voltage-buck and voltage-boost capability This could lose the effectiveness and request all the more detecting for controlling the additional new stages. This paper is proposing another group of broadened help semi Z - source inverter (ZSI) to fill the exploration hole left in the improvement of ZSI. These new topologies can be worked with same regulation strategies that were produced for unique ZSI. Likewise, they have a similar number of dynamic switches as unique ZSI saving the single-organize nature of ZSI. Proposed topologies are dissected in the enduring state and their exhibitions are approved utilizing recreated comes about acquired in MATLAB/Simulink. Besides, they are tentatively approved with comes about acquired from a model created in the research facility. The trend of fast increase of the PV energy use is related to the increasing efficiency of solar cells as well as the improvements of manufacturing technology of solar panels.

  3. Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nelson, Austin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Miller, Brian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bell, Frances [SolarCity, San Mateo, CA (United States); McCarty, Michael [SolarCity, San Mateo, CA (United States)

    2016-07-01

    As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC

  4. EXAMINING A SERIES RESONANT INVERTER CIRCUIT TO USE IN THE PHOTOVOLTAIC ENERGY CONVERSION SYSTEMS

    Directory of Open Access Journals (Sweden)

    Engin ÇETİN

    2004-03-01

    Full Text Available As we know, solar energy is the energy source which is environment friendly, renewable, and can be found easily. Particularly, in the recent years, interest on producing electrical energy by alternative energy sources increased because of the fact that underground sources are not enough to produce energy in the future and also these sources cause enviromental pollution. The solar energy is one of the most popular one among the alternative energy sources. Photovoltaic systems produce the electrical energy from the sunlight. In this study, a series resonant inverter circuit which is used in the photovoltaic energy conversion systems has been examined.Effects of the series resonant inverter circuit on the photovoltaic energy conversion system have been investigated and examined

  5. Addressable inverter matrix for process and device characterization

    Science.gov (United States)

    Buehler, M. G.; Sayah, H. R.

    1985-01-01

    The addressable inverter matrix consists of 222 inverters each accessible with the aid of a shift register. The structure has proven useful in characterizing the variability of inverter transfer curves and in diagnosing processing faults. For good 3-micron CMOS bulk inverters investigated, the percent standard deviation of the inverter threshold voltage was less than one percent and the inverter gain (the slope of the inverter transfer curve at the inverter threshold vltage) was less than 3 percent. The average noise margin for the inverters was near 2 volts for a power supply voltage of 5 volts. The specific faults studied included undersize pull-down transistor widths and various open contacts in the matrix.

  6. Inverted Polarity Thunderstorms Linked with Elevated Cloud Base Height

    Science.gov (United States)

    Cummins, K. L.; Williams, E.

    2016-12-01

    The great majority of thunderstorms worldwide exhibit gross positive dipole structure, produce intracloud lightning that reduces this positive dipole (positive intracloud flashes), and produce negative cloud-to-ground lightning from the lower negative end of this dipole. During the STEPS experiment in 2000 much new evidence for thunderstorms (or cells within multi-cellular storms) with inverted polarity came to light, both from balloon soundings of electric field and from LMA analysis. Many of the storms with inverted polarity cells developed in eastern Colorado. Fleenor et al. (2009) followed up after STEPS to document a dominance of positive polarity CG lightning in many of these cases. In the present study, surface thermodynamic observations (temperature and dew point temperature) have been used to estimate the cloud base heights and temperatures at the time of the Fleenor et al. lightning observations. It was found that when more than 90% of the observed CG lightning polarity within a storm is negative, the cloud base heights were low (2000 m AGL or lower, and warmer, with T>10 C), and when more than 90% of the observed CG lightning within a storm was positive, the cloud base heights were high (3000 m AGL or higher, and colder, with Tmixed polarity were generally associated with intermediate cloud base heights. These findings on inverted polarity thunderstorms are remarkably consistent with results in other parts of the world where strong instability prevails in the presence of high cloud base height: the plateau regions of China (Liu et al., 1989; Qie et al., 2005), and in pre-monsoon India (Pawar et al., 2016), particularly when mixed polarity cases are excluded. Calculations of adiabatic cloud water content for lifting from near 0 oC cast some doubt on earlier speculation (Williams et al., 2005) that the graupel particles in these inverted polarity storms attain a wet growth condition, and so exhibit positive charging following laboratory experiments. This

  7. Importance of the inverted control in measuring holistic face processing with the composite effect and part-whole effect.

    Directory of Open Access Journals (Sweden)

    Elinor eMcKone

    2013-02-01

    Full Text Available Holistic coding for faces is shown in several illusions that demonstrate integration of the percept across the entire face. The illusions occur upright but, crucially, not inverted. Converting the illusions into experimental tasks that measure their strength – and thus index degree of holistic coding – is often considered straightforward yet in fact relies on a hidden assumption, namely that there is no contribution to the experimental measure from secondary cognitive factors. For the composite effect, a relevant secondary factor is size of the "spotlight" of visuospatial attention. The composite task assumes this spotlight can be easily restricted to the target half (e.g., top half of the compound face stimulus. Yet, if this assumption were not true then a large spotlight, in the absence of holistic perception, could produce a false composite effect, present even for inverted faces and contributing partially to the score for upright faces. We review evidence that various factors can influence spotlight size: race/culture (Asians often prefer a more global distribution of attention than Caucasians; sex (females can be more global; appearance of the join or gap between face halves; and location of the eyes, which typically attract attention. Results from 5 experiments then show inverted faces can sometimes produce large false composite effects, and imply that whether this happens or not depends on complex interactions between causal factors. We also report, for both identity and expression, that only top-half-face targets (containing eyes produce valid composite measures. A sixth experiment demonstrates an example of a false inverted part-whole effect, where encoding-specificity is the secondary cognitive factor. We conclude the inverted face control should be tested in all composite and part-whole studies, and an effect for upright faces should be interpreted as a pure measure of holistic processing only when the experimental design produces

  8. Importance of the Inverted Control in Measuring Holistic Face Processing with the Composite Effect and Part-Whole Effect

    Science.gov (United States)

    McKone, Elinor; Davies, Anne Aimola; Darke, Hayley; Crookes, Kate; Wickramariyaratne, Tushara; Zappia, Stephanie; Fiorentini, Chiara; Favelle, Simone; Broughton, Mary; Fernando, Dinusha

    2013-01-01

    Holistic coding for faces is shown in several illusions that demonstrate integration of the percept across the entire face. The illusions occur upright but, crucially, not inverted. Converting the illusions into experimental tasks that measure their strength – and thus index degree of holistic coding – is often considered straightforward yet in fact relies on a hidden assumption, namely that there is no contribution to the experimental measure from secondary cognitive factors. For the composite effect, a relevant secondary factor is size of the “spotlight” of visuospatial attention. The composite task assumes this spotlight can be easily restricted to the target half (e.g., top-half) of the compound face stimulus. Yet, if this assumption were not true then a large spotlight, in the absence of holistic perception, could produce a false composite effect, present even for inverted faces and contributing partially to the score for upright faces. We review evidence that various factors can influence spotlight size: race/culture (Asians often prefer a more global distribution of attention than Caucasians); sex (females can be more global); appearance of the join or gap between face halves; and location of the eyes, which typically attract attention. Results from five experiments then show inverted faces can sometimes produce large false composite effects, and imply that whether this happens or not depends on complex interactions between causal factors. We also report, for both identity and expression, that only top-half face targets (containing eyes) produce valid composite measures. A sixth experiment demonstrates an example of a false inverted part-whole effect, where encoding-specificity is the secondary cognitive factor. We conclude the inverted face control should be tested in all composite and part-whole studies, and an effect for upright faces should be interpreted as a pure measure of holistic processing only when the experimental design produces no

  9. Inverter design for high frequency power distribution

    Science.gov (United States)

    King, R. J.

    1985-01-01

    A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.

  10. Multilevel Inverter by Cascading Industrial VSI

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Pedersen, John Kim

    2002-01-01

    In this paper the modularity concept applied to medium-voltage adjustable speed drives is addressed. First, the single-phase cascaded voltage-source inverter that uses series connection of IGBT H-bridge modules with isolated dc-buses is presented. Next, a novel three-phase cascaded voltage......-source inverter that uses three IGBT triphase inverter modules along with an output transformer to obtain a 3 p.u. multilevel output voltage is introduced. The system yields in high-quality multistep voltage with up to 4 levels and low dv/dt, balanced operation of the inverter modules, each supplying a third...... of the motor rated kVA. The concept of using cascaded inverters is further extended to a new modular motor-modular inverter system where the motor winding connections are reconnected into several three-phase groups, either six-lead or 12-lead connection according to the voltage level, each powered...

  11. Gas cooled traction drive inverter

    Science.gov (United States)

    Chinthavali, Madhu Sudhan

    2013-10-08

    The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.

  12. Embedded EZ-Source Inverters

    DEFF Research Database (Denmark)

    Chiang Loh, Poh; Gao, Feng; Blaabjerg, Frede

    2010-01-01

    overvoltage oscillations to the system. Therefore, Z-source inverters are, in effect, safer and less complex and can be implemented using only passive elements with no additional active semiconductor needed. Believing in the prospects of Z-source inverters, this paper contributes by introducing a new family...

  13. Embedded EZ-Source Inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Gao, F.

    2008-01-01

    -voltage oscillations to the system. Therefore, Z-source inverters are in effect safer and less complex, and can be implemented using only passive elements with no additional active semiconductor needed. Believing in the prospects of Z-source inverters, this paper contributes by introducing a new family of embedded EZ...

  14. Enhanced Buck–Boost Neutral-Point-Clamped Inverters With Simple Capacitive-Voltage Balancing

    DEFF Research Database (Denmark)

    Tan, Kuan Khoon; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    introduced for extending the inverters’ variation range to include voltageboost operation, but they generally require the inclusion of large passive components or have not yet been optimized in terms of waveform quality. The balancing of their capacitive voltages using a simple technique has also not yet...... simultaneously, two new buck–boost NPC inverters with simple capacitive-voltage-balancing capability are proposed. Both inverters are demonstrated to exhibit a doubling of voltage gain, with one of them also shown to produce a better output waveform quality. Simulation and experimental results are provided...

  15. Pre-inverted SESAME data table construction enhancements to correct unexpected inverse interpolation pathologies in EOSPAC 6

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sheppard, Daniel G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-01

    It was recently demonstrated that EOSPAC 6 continued to incorrectly create and interpolate pre-inverted SESAME data tables after the release of version 6.3.2beta.2. Significant interpolation pathologies were discovered to occur when EOSPAC 6's host software enabled pre-inversion with the EOS_INVERT_AT_SETUP option. This document describes a solution that uses data transformations found in EOSPAC 5 and its predecessors. The numerical results and performance characteristics of both the default and pre-inverted interpolation modes in both EOSPAC 6.3.2beta.2 and the fixed logic of EOSPAC 6.4.0beta.1 are presented herein, and the latter software release is shown to produce significantly-improved numerical results for the pre-inverted interpolation mode.

  16. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z......-source inverter are introduced here for operating the proposed inverter with voltage buck–boost energy conversion ability and five-level phase voltage switching. These characteristic features are in fact always ensured at the inverter terminal output by simply adopting a properly designed carrier modulation...

  17. Component-Minimized Buck-Boost Voltage Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    This paper presents the design of buck-boost B4 inverters that can be derived from either Ćuk- or SEPIC-derived buck-boost B6 inverters. Unlike traditional inverters, the integration of front-end voltage boost circuitry and inverter circuitry allows it to perform buck-boost voltage inversion...... between capacitors. Modulation wise, the proposed buck-boost B4 inverters can be controlled using a carefully designed carrier-based pulse-width modulation (PWM) scheme that will always ensure balanced threephase outputs as desired, while simultaneously achieving minimal voltage stress across...

  18. On Invertible Sampling and Adaptive Security

    DEFF Research Database (Denmark)

    Ishai, Yuval; Kumarasubramanian, Abishek; Orlandi, Claudio

    2011-01-01

    functionalities was left open. We provide the first convincing evidence that the answer to this question is negative, namely that some (randomized) functionalities cannot be realized with adaptive security. We obtain this result by studying the following related invertible sampling problem: given an efficient...... sampling algorithm A, obtain another sampling algorithm B such that the output of B is computationally indistinguishable from the output of A, but B can be efficiently inverted (even if A cannot). This invertible sampling problem is independently motivated by other cryptographic applications. We show......, under strong but well studied assumptions, that there exist efficient sampling algorithms A for which invertible sampling as above is impossible. At the same time, we show that a general feasibility result for adaptively secure MPC implies that invertible sampling is possible for every A, thereby...

  19. Preparation of inverted medium and processing in the inverted medium

    International Nuclear Information System (INIS)

    Zafarullah, Ijaz; Tian Minghzen; Chang Tiejun; Randall Babbitt, W.

    2007-01-01

    The processing of weak optical signals in spatial-spectral holographic (SSH) materials coherently inverted with optical frequency chirped pulses were investigated. Simulations and experimental studies in Tm 3+ :YAG were conducted to characterize the parameters of the frequency chirped laser pulse used to invert the SSH material in order to obtain high photon echo efficiency for SSH lidar processing. Collinear and angled beam geometries and single shot and accumulated processes were investigated. Echo efficiencies as high as 450% were measured, significantly higher than the typical stimulated photon echo efficiency of 10%

  20. Preparation of inverted medium and processing in the inverted medium

    Energy Technology Data Exchange (ETDEWEB)

    Zafarullah, Ijaz [Department of Physics, Montana State University, Bozeman, MT 59717 (United States)]. E-mail: ijaz@montana.edu; Tian Minghzen [Department of Physics, Montana State University, Bozeman, MT 59717 (United States); Chang Tiejun [The Spectrum Laboratory, Montana State University, Bozeman, MT 59717 (United States); Randall Babbitt, W. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States)

    2007-11-15

    The processing of weak optical signals in spatial-spectral holographic (SSH) materials coherently inverted with optical frequency chirped pulses were investigated. Simulations and experimental studies in Tm{sup 3+}:YAG were conducted to characterize the parameters of the frequency chirped laser pulse used to invert the SSH material in order to obtain high photon echo efficiency for SSH lidar processing. Collinear and angled beam geometries and single shot and accumulated processes were investigated. Echo efficiencies as high as 450% were measured, significantly higher than the typical stimulated photon echo efficiency of 10%.

  1. Solar Charged Stand Alone Inverter

    OpenAIRE

    M.Vasugi; Prof R.Jayaraman

    2014-01-01

    This paper deals with solar powered stand alone inverter which converts the variable dc output of a photovoltaic solar panel into ac that can be fed to loads. Stand alone inverters are used in systems where the inverter get its energy from batteries charged by photo voltaic arrays. A charge controller limits the rate at which electric current is added to or drawn from electric batteries. This charge discharge controller is needed to prevent the battery from being overcharged o...

  2. 21 CFR 184.1859 - Invert sugar.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Invert sugar. 184.1859 Section 184.1859 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... Substances Affirmed as GRAS § 184.1859 Invert sugar. (a) Invert sugar (CAS Reg. No. 8013-17-0) is an aqueous...

  3. Simplified High-Power Inverter

    Science.gov (United States)

    Edwards, D. B.; Rippel, W. E.

    1984-01-01

    Solid-state inverter simplified by use of single gate-turnoff device (GTO) to commutate multiple silicon controlled rectifiers (SCR's). By eliminating conventional commutation circuitry, GTO reduces cost, size and weight. GTO commutation applicable to inverters of greater than 1-kilowatt capacity. Applications include emergency power, load leveling, drives for traction and stationary polyphase motors, and photovoltaic-power conditioning.

  4. Aalborg Inverter - A New Type of “Buck in Buck, Boost in Boost” Grid-Tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Ji, Junhao; Blaabjerg, Frede

    2015-01-01

    This paper presents a new family of high efficiency dc/ac grid-tied inverter with a wide variation of input dc voltage. It is a “boost in boost, buck in buck” inverter, meaning that only one power stage works at high frequency in order to achieve minimum switching loss. The minimum voltage drop...... of the filtering inductor in the power loop is achieved to reduce the conduction power loss in both “boost” and “buck” mode. The principle of operation is demonstrated through the analysis on the equivalent circuits of a “half-bridge” single-phase inverter. The theoretical analysis shows that when input dc voltage...... is larger than the magnitude of the ac voltage, it is a voltage-source inverter, and on the contrary it is current-source inverter in the other mode. A 220 V/50 Hz/ 2000 W prototype has been constructed. Simulations and experiments show that it has a good control and system performance....

  5. Multilevel DC Link Inverter for Brushless Permanent Magnet Motors with Very Low Inductance

    International Nuclear Information System (INIS)

    Su, G.J.

    2001-01-01

    Due to their long effective air gaps, permanent magnet motors tend to have low inductance. The use of ironless stator structure in present high power PM motors (several tens of kWs) reduces the inductance even further ( and lt; 100(micro)H). This low inductance imposes stringent current regulation demands for the inverter to obtain acceptable current ripple. An analysis of the current ripple for these low inductance brushless PM motors shows that a standard inverter with the most commonly used IGBT switching devices cannot meet the current regulation demands and will produce unacceptable current ripples due to the IGBT's limited switching frequency. This paper introduces a new multilevel dc link inverter, which can dramatically reduce the current ripple for brushless PM motor drives. The operating principle and design guidelines are included

  6. Methane hydrate dissociation using inverted five-spot water flooding method in cubic hydrate simulator

    International Nuclear Information System (INIS)

    Li, Gang; Li, Xiao-Sen; Li, Bo; Wang, Yi

    2014-01-01

    The combination forms of the hydrate dissociation methods in different well systems are divided into 6 main patterns. Dissociation processes of methane hydrate in porous media using the inverted five-spot water flooding method (Pattern 4) are investigated by the experimental observation and numerical simulation. In situ methane hydrate is synthesized in the Cubic Hydrate Simulator (CHS), a 5.832-L cubic reactor. A center vertical well is used as the hot water injection well, while the four vertical wells at the corner are the gas and water production wells. The gas production begins simultaneously with the hot water injection, while after approximately 20 min of compression, the water begins to be produced. One of the common characteristics of the inverted five-spot water flooding method is that both the gas and water production rates decrease with the reduction of the hydrate dissociation rate. The evaluation of the energy efficiency ratio might indicate the inverted five-spot water flooding as a promising gas producing method from the hydrate reservoir. - Highlights: • A three-dimensional 5.8-L cubic pressure vessel is developed. • Gas production of hydrate using inverted five-spot flooding method is studied. • Water/gas production rate and energy efficiency ratio are evaluated. • Temperature distributions of numerical simulation and experiment agree well. • Hydrate dissociation process is a moving boundary problem in this study

  7. Online Variable Topology-Type Photovoltaic Grid-Connected Inverter

    DEFF Research Database (Denmark)

    Wu, Fengjiang; Sun, Bo; Duan, Jiandong

    2015-01-01

    In photovoltaic (PV) grid-connected generation system, the key focus is how to expand the generation range of the PV array and enhance the total efficiency of the system. This paper originally derived expressions of the total loss and grid current total harmonics distortions of cascaded inverter...... and H-bridge inverter under the conditions of variable output voltage and power of the PV array. It is proved that, compared with the H-bridge inverter, the operation range of the cascaded inverter is wider, whereas the total loss is larger. Furthermore, a novel online variable topology-type grid......-connected inverter is proposed. A bidirectional power switch is introduced into the conventional cascaded inverter to connect the negative terminals of the PV arrays. When the output voltages of the PV arrays are lower, the proposed inverter works under cascaded inverter mode to obtain wider generation range. When...

  8. The effects of inverter magnetic fields on early seed germination of mung beans.

    Science.gov (United States)

    Huang, Hsin-Hsiung; Wang, Show-Ran

    2008-12-01

    The biological effects of extremely low frequency magnetic fields (ELF MFs) on living organisms have been explored in many studies. Most of them demonstrate the biological effects caused by 50/60 Hz magnetic fields or pulsed magnetic fields. However, as the development of power electronics flourishes, the magnetic fields induced are usually in other different waveforms. This study aims to assess the effects of magnetic fields generated by inverter systems on the early growth of plants using mung beans as an example. In the experiment, an inverter which can produce sinusoidal pulsed width modulation (SPWM) voltages was used to drive 3 specially made circular coils and an AC motor. Six SPWM voltages with different fundamental frequencies (10, 20, 30, 40, 50, and 60 Hz) set on the inverter drive the circuit to produce the specific kinds of MFs. The results indicate that the magnetic field induced by a 20 or 60 Hz SPWM voltage has an enhancing effect on the early growth of mung beans, but the magnetic fields induced by SPWM voltages of other frequencies (30, 40, and 50 Hz) have an inhibitory effect, especially at 50 Hz.

  9. Inverted base pavements: construction and performance

    KAUST Repository

    Papadopoulos, Efthymios

    2017-05-11

    Inverted base pavements involve a well-compacted granular aggregate base built between a thin asphalt concrete layer and a cement-treated base. Inverted base pavements can be constructed using conventional equipment and procedures but require proper quality control. This study reviews the extensive South African experience and case histories in the USA. Accumulating evidence suggests that inverted base pavements are a viable alternative and can outperform conventional pavements at a lower cost. Inverted base pavements rely on the complementary interaction between layers. The cement-treated base provides a stiff foundation for efficient compaction and constrains the deformation of the stress-sensitive granular aggregate base. The thin asphalt surface layer deforms as a membrane and develops low tensile stress. Additional large-scale field tests should be conducted to assess the performance of inverted base pavement designs in a wide range of conditions relevant to the USA.

  10. Aalborg Inverter - A new type of “Buck in Buck, Boost in Boost” Grid-tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Blaabjerg, Frede

    2013-01-01

    This paper presents a new family of high efficiency DC/AC grid-tied inverter with a wide variation of input DC voltage. It is a kind of “Boost in Boost, Buck in Buck” inverter, meaning that only one power stage works at the high frequency to achieve the minimum switching loss. Furthermore......, the minimum filtering inductance in the power loop is achieved to reduce the conduction power loss whether in “Boost” or “Buck” mode. In theory, it can achieve higher efficiency than other inverters under the same condition of input DC voltage. The principle of operation is fully illustrated through...... the analysis on the equivalent circuits of a “three-level” single-phase inverter. Simulations show it has good control performance....

  11. CLOSED LOOP CONTROL OF EMBEDDED Z-SOURCE INVERTER WITH FUZZY CONTROLLER FOR SOLAR PV APPLICATIONS

    OpenAIRE

    Midde Mahesh*, K. Leleedhar Rao

    2017-01-01

    This paper proposes the use of Embedded Z –source inverter system with fuzzy controller for Solar Photo Voltaic (PV) applications with adjustable speed drives. Closed loop operation FUZZY control strategies of EZSI system are proposed. EZSI produces the same voltage gain as Z-source inverter (ZSI) but due to the DC sources embedded within the X- shaped impedance network, it has the added advantage of inherent source filtering capability and also reduced capacitor sizing. This can be achiev...

  12. Efficient/reliable dc-to-dc inverter circuit

    Science.gov (United States)

    Pasciutti, E. R.

    1970-01-01

    Feedback loop, which contains an inductor in series with a saturable reactor, is added to a standard inverter circuit to permit the inverter power transistors to be switched in a controlled and efficient manner. This inverter is applicable where the power source has either high or low impedance properties.

  13. High voltage series resonant inverter ion engine screen supply. [SCR series resonant inverter for space applications

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Shank, J. H.

    1974-01-01

    A high-voltage, high-power LC series resonant inverter using SCRs has been developed for an Ion Engine Power Processor. The inverter operates within 200-400Vdc with a maximum output power of 2.5kW. The inverter control logic, the screen supply electrical and mechanical characteristics, the efficiency and losses in power components, regulation on the dual feedback principle, the SCR waveforms and the component weight are analyzed. Efficiency of 90.5% and weight density of 4.1kg/kW are obtained.

  14. Modulation of Current Source Inverter

    Directory of Open Access Journals (Sweden)

    Golam Reza Arab Markadeh

    2011-04-01

    Full Text Available Direct torque control with Current Source Inverter (CSI instead of voltage source inverter is so appropriate because of determining the torque of induction motor with machine current and air gap flux. In addition, Space-Vector Modulation (SVM is a more proper method for CSI because of low order harmonics reduction, lower switching frequency and easier implementation. This paper introduces the SVM method for CSI and uses the proposed inverter for vector control of an induction motor. The simulation results illustrate fast dynamic response and desirable torque and speed output. Fast and accurate response to changes of speed and load torque reference completely proves the prominence of this method.

  15. Detecting and mitigating inverter aging

    International Nuclear Information System (INIS)

    Gunther, W.E.; Taylor, J.H.; Aggarwal, S.K.

    1988-01-01

    Nuclear power plants use inverters to supply power to safety-related equipment, instrumentation, and controls. They convert direct current (dc) to alternating current (ac) power, thereby making low voltage ac power available even under a station blackout condition. As part of the U.S. NRC's nuclear plant aging research (NPAR) program, the operating experience of this equipment has been analyzed to determine the dominant failure modes and causes. This paper summarizes that data, and then describes methods which can be employed to detect inverter degradation prior to failure, as well as methods to minimize the failure effects. In both cases, the mitigation of inverter aging is emphasized

  16. Diode-Assisted Buck-Boost Current Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Cai, Liang; Loh, P.C.

    2007-01-01

    This paper presents a couple of novel current source inverters (CSIs) with the enhanced current buckboost capability. With the unique diode-inductor network added between current source inverter circuitry and current boost elements, the proposed buck-boost current source inverters demonstrate...... uninfluenced. Lastly, all theoretical findings were verified experimentally using constructed laboratory prototypes....

  17. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV Systems with Maximum Power Point Tracking (MPPT

    Directory of Open Access Journals (Sweden)

    Tofael Ahmed

    2014-06-01

    Full Text Available In this paper, a single phase doubly grounded semi-Z-source inverter with maximum power point tracking (MPPT is proposed for photovoltaic (PV systems. This proposed system utilizes a single-ended primary inductor (SEPIC converter as DC-DC converter to implement the MPPT algorithm for tracking the maximum power from a PV array and a single phase semi-Z-source inverter for integrating the PV with AC power utilities. The MPPT controller utilizes a fast-converging algorithm to track the maximum power point (MPP and the semi-Z-source inverter utilizes a nonlinear SPWM to produce sinusoidal voltage at the output. The proposed system is able to track the MPP of PV arrays and produce an AC voltage at its output by utilizing only three switches. Experimental results show that the fast-converging MPPT algorithm has fast tracking response with appreciable MPP efficiency. In addition, the inverter shows the minimization of common mode leakage current with its ground sharing feature and reduction of the THD as well as DC current components at the output during DC-AC conversion.

  18. Live Imaging of Shoot Meristems on an Inverted Confocal Microscope Using an Objective Lens Inverter Attachment

    Science.gov (United States)

    Nimchuk, Zachary L.; Perdue, Tony D.

    2017-01-01

    Live imaging of above ground meristems can lead to new insights in plant development not possible from static imaging of fixed tissue. The use of an upright confocal microscope offers several technical and biological advantages for live imaging floral or shoot meristems. However, many departments and core facilities possess only inverted confocal microscopes and lack the funding for an additional upright confocal microscope. Here we show that imaging of living apical meristems can be performed on existing inverted confocal microscopes with the use of an affordable and detachable InverterScope accessory. PMID:28579995

  19. Live Imaging of Shoot Meristems on an Inverted Confocal Microscope Using an Objective Lens Inverter Attachment.

    Science.gov (United States)

    Nimchuk, Zachary L; Perdue, Tony D

    2017-01-01

    Live imaging of above ground meristems can lead to new insights in plant development not possible from static imaging of fixed tissue. The use of an upright confocal microscope offers several technical and biological advantages for live imaging floral or shoot meristems. However, many departments and core facilities possess only inverted confocal microscopes and lack the funding for an additional upright confocal microscope. Here we show that imaging of living apical meristems can be performed on existing inverted confocal microscopes with the use of an affordable and detachable InverterScope accessory.

  20. DC-to-AC inverter ratio failure detector

    Science.gov (United States)

    Ebersole, T. J.; Andrews, R. E.

    1975-01-01

    Failure detection technique is based upon input-output ratios, which is independent of inverter loading. Since inverter has fixed relationship between V-in/V-out and I-in/I-out, failure detection criteria are based on this ratio, which is simply inverter transformer turns ratio, K, equal to primary turns divided by secondary turns.

  1. Choose your business partners carefully. The bankruptcy of the current inverter producer RES affected many of its business partners; Drum pruefe, wer sich bindet. Wie die Insolvenz des Wechselrichterherstellers RES eine Vielzahl an Geschaedigten schafft

    Energy Technology Data Exchange (ETDEWEB)

    Rutschmann, I.

    2008-02-15

    Customers of the RES GmbH current inverter producer complained about disturbances, outages, and low yields. Now, the producer has filed for insolvency; business partners will probably lose their warranty claim and also their contact for repair and replacement parts. IPE, a partner fitter's company, even fears of going bankrupt too. All partners agree that in the future, they will limit their business activities to partners they know better. (orig.)

  2. NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric

    Science.gov (United States)

    Companies | Energy Systems Integration Facility | NREL NREL Evaluates Advanced Solar Inverter Performance for Hawaiian Electric Companies NREL Evaluates Advanced Solar Inverter Performance for Hawaiian performance and impacts of today's advanced solar inverters, as well as proprietary feedback to the inverter

  3. Pulsewidth-modulated 2-source neutral-point-clamped inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chang; Gao, Feng

    2007-01-01

    This paper presents the careful integration of a newly proposed Z-source topological concept to the basic neutral-point-clamped (NPC) inverter topology for designing a three-level inverter with both voltage-buck and voltage-boost capabilities. The designed Z-source NPC inverter uses two unique X......-shaped inductance-capacitance (LC) impedance networks that are connected between two isolated dc input power sources and its inverter circuitry for boosting its AC output voltage. Through the design of an appropriate pulsewidth-modulation (PWM) algorithm, the two impedance networks can be short......-circuited sequentially (without shooting through the inverter full DC link) for implementing the ldquonearest-three-vectorrdquo modulation principle with minimized harmonic distortion and device commutations per half carrier cycle while performing voltage boosting. With only a slight modification to the inverter PWM...

  4. Implementation of floating gate MOSFET in inverter for threshold voltage tunability

    Directory of Open Access Journals (Sweden)

    Musa F.A.S.

    2017-01-01

    Full Text Available This paper presents the ability of floating gate MOSFET (FGMOS threshold voltage to be programmed or tuned which is exploited to improve the performance of electronic circuit design. This special characteristic owns by FGMOS is definitely contributes towards low voltage and low power circuit design. The comparison of threshold voltage between FGMOS and conventional NMOS is done in order to prove that FGMOS is able to produce a lower threshold voltage compared to conventional NMOS. In addition, in this paper, an implementation of FGMOS into inverter circuit is also done to show the programmability of FGMOS threshold voltage. The operations of the inverter circuits are verified using Sypnopsys simulation in 0.1μm CMOS technology with supply voltage of 1.8V.

  5. On Stability of Voltage Source Inverters in Weak Grids

    DEFF Research Database (Denmark)

    Adib, Aswad; Mirafza, Behrooz; Wang, Xiongfei

    2018-01-01

    As the number of inverters increases in the power grid, the stability of grid-tied inverters becomes an important concern for the power industry. In particular, a weak grid can lead to voltage fluctuations at the inverter terminals and consequently cause inverter instability. In this paper, impac...

  6. Hardness of deriving invertible sequences from finite state machines

    DEFF Research Database (Denmark)

    Hierons, Robert M.; Mousavi, Mohammad Reza; Thomsen, Michael Kirkedal

    2017-01-01

    invertible sequences; these allow one to construct additional UIOs once a UIO has been found. We consider three optimisation problems associated with invertible sequences: deciding whether there is a (proper) invertible sequence of length at least K; deciding whether there is a set of invertible sequences...

  7. Towards Efficient Positional Inverted Index †

    Directory of Open Access Journals (Sweden)

    Petr Procházka

    2017-02-01

    Full Text Available We address the problem of positional indexing in the natural language domain. The positional inverted index contains the information of the word positions. Thus, it is able to recover the original text file, which implies that it is not necessary to store the original file. Our Positional Inverted Self-Index (PISI stores the word position gaps encoded by variable byte code. Inverted lists of single terms are combined into one inverted list that represents the backbone of the text file since it stores the sequence of the indexed words of the original file. The inverted list is synchronized with a presentation layer that stores separators, stop words, as well as variants of the indexed words. The Huffman coding is used to encode the presentation layer. The space complexity of the PISI inverted list is O ( ( N − n ⌈ log 2 b N ⌉ + ( ⌊ N − n α ⌋ + n × ( ⌈ log 2 b n ⌉ + 1 where N is a number of stems, n is a number of unique stems, α is a step/period of the back pointers in the inverted list and b is the size of the word of computer memory given in bits. The space complexity of the presentation layer is O ( − ∑ i = 1 N ⌈ log 2 p i n ( i ⌉ − ∑ j = 1 N ′ ⌈ log 2 p j ′ ⌉ + N with respect to p i n ( i as a probability of a stem variant at position i, p j ′ as the probability of separator or stop word at position j and N ′ as the number of separators and stop words.

  8. A Hybrid, Current-Source/Voltage-Source Power Inverter Circuit

    DEFF Research Database (Denmark)

    Trzynadlowski, Andrzej M.; Patriciu, Niculina; Blaabjerg, Frede

    2001-01-01

    A combination of a large current-source inverter and a small voltage-source inverter circuits is analyzed. The resultant hybrid inverter inherits certain operating advantages from both the constituent converters. In comparison with the popular voltage-source inverter, these advantages include...... reduced switching losses, improved quality of output current waveforms, and faster dynamic response to current control commands. Description of operating principles and characteristics of the hybrid inverter is illustrated with results of experimental investigation of a laboratory model....

  9. Switching Characteristics of Ferroelectric Transistor Inverters

    Science.gov (United States)

    Laws, Crystal; Mitchell, Coey; MacLeod, Todd C.; Ho, Fat D.

    2010-01-01

    This paper presents the switching characteristics of an inverter circuit using a ferroelectric field effect transistor, FeFET. The propagation delay time characteristics, phl and plh are presented along with the output voltage rise and fall times, rise and fall. The propagation delay is the time-delay between the V50% transitions of the input and output voltages. The rise and fall times are the times required for the output voltages to transition between the voltage levels V10% and V90%. Comparisons are made between the MOSFET inverter and the ferroelectric transistor inverter.

  10. Novel, Four-Switch, Z-Source Three-Phase Inverter

    DEFF Research Database (Denmark)

    Antal, Robert; Muntean, Nicolae; Boldea, Ion

    2010-01-01

    This paper presents a new z-source three phase inverter topology. The proposed topology combines the advantages of a traditional four-switch three-phase inverter with the advantages of the z impedance network (one front-end diode, two inductors and two X connected capacitors). This new topology......, besides the self-boost property, has low switch count and it can operate as a buck-boost inverter. In contrast to standard four-switch three-phase inverter which operates at half dc input voltage the proposed four-switch z-source inverter, by self boosting, brings the output voltage at same (or higher......) value as in six switch standard three-phase inverter. The article presents the derivation of the equations describing the operation of the converter based on space vector analysis, validation through digital simulations in PSIM and preliminary experimental results on a laboratory setup with a dsPIC30F...

  11. Transistorized PWM inverter-induction motor drive system

    Science.gov (United States)

    Peak, S. C.; Plunkett, A. B.

    1982-01-01

    This paper describes the development of a transistorized PWM inverter-induction motor traction drive system. A vehicle performance analysis was performed to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of inverter and motor specifications. The inverter was a transistorized three-phase bridge using General Electric power Darlington transistors. The description of the design and development of this inverter is the principal object of this paper. The high-speed induction motor is a design which is optimized for use with an inverter power source. The primary feedback control is a torque angle control with voltage and torque outer loop controls. A current-controlled PWM technique is used to control the motor voltage. The drive has a constant torque output with PWM operation to base motor speed and a constant horsepower output with square wave operation to maximum speed. The drive system was dynamometer tested and the results are presented.

  12. Integral inverter/battery charger for use in electric vehicles

    Science.gov (United States)

    Thimmesch, D.

    1983-01-01

    The design and test results of a thyristor based inverter/charger are discussed. A battery charger is included integral to the inverter by using a subset of the inverter power circuit components. The resulting charger provides electrical isolation between the vehicle propulsion battery and ac line and is capable of charging a 25 kWh propulsion battery in 8 hours from a 220 volt ac line. The integral charger employs the inverter commutation components at a resonant ac/dc isolated converter rated at 3.6 kW. Charger efficiency and power factor at an output power of 3.6 kW are 86% and 95% respectively. The inverter, when operated with a matching polyphase ac induction motor and nominal 132 volt propulsion battery, can provide a peak shaft power of 34 kW (45 ph) during motoring operation and 45 kW (60 hp) during regeneration. Thyristors are employed for the inverter power switching devices and are arranged in an input-commutated topology. This configuration requires only two thyristors to commutate the six main inverter thyristors. Inverter efficiency during motoring operation at motor shaft speeds above 450 rad/sec (4300 rpm) is 92-94% for output power levels above 11 KW (15 hp). The combined ac inverter/charger package weighs 47 kg (103 lbs).

  13. Design optimization of grid-connected PV inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    The DC/AC inverters are the key elements in grid-connected PV energy production systems. In this paper, new design optimization techniques focused on transformerless (very high efficiency) PV inverters are proposed. They have been developed based on an analysis of the deficiencies of the current......, state-of-the-art PV inverters design technology, which limits the amount of PV energy supplied into the electric grid. The influences of the electric grid regulations and standards and the PV array operational characteristics on the design of grid-connected PV inverters have also been considered....... The simulation results verify that the proposed optimization techniques enable the maximization of the PV energy injected into the electric grid by the optimized PV installation....

  14. Advanced DC/AC inverters applications in renewable energy

    CERN Document Server

    Luo, Fang Lin

    2013-01-01

    DC/AC inversion technology is of vital importance for industrial applications, including electrical vehicles and renewable energy systems, which require a large number of inverters. In recent years, inversion technology has developed rapidly, with new topologies improving the power factor and increasing power efficiency. Proposing many novel approaches, Advanced DC/AC Inverters: Applications in Renewable Energy describes advanced DC/AC inverters that can be used for renewable energy systems. The book introduces more than 100 topologies of advanced inverters originally developed by the authors,

  15. Selective harmonic elimination strategy in eleven level inverter for PV system with unbalanced DC sources

    Science.gov (United States)

    Ghoudelbourk, Sihem.; Dib, D.; Meghni, B.; Zouli, M.

    2017-02-01

    The paper deals with the multilevel converters control strategy for photovoltaic system integrated in distribution grids. The objective of the proposed work is to design multilevel inverters for solar energy applications so as to reduce the Total Harmonic Distortion (THD) and to improve the power quality. The multilevel inverter power structure plays a vital role in every aspect of the power system. It is easier to produce a high-power, high-voltage inverter with the multilevel structure. The topologies of multilevel inverter have several advantages such as high output voltage, lower total harmonic distortion (THD) and reduction of voltage ratings of the power semiconductor switching devices. The proposed control strategy ensures an implementation of selective harmonic elimination (SHE) modulation for eleven levels. SHE is a very important and efficient strategy of eliminating selected harmonics by judicious selection of the firing angles of the inverter. Harmonics elimination technique eliminates the need of the expensive low pass filters in the system. Previous research considered that constant and equal DC sources with invariant behavior; however, this research extends earlier work to include variant DC sources, which are typical of lead-acid batteries when used in system PV. This Study also investigates methods to minimize the total harmonic distortion of the synthesized multilevel waveform and to help balance the battery voltage. The harmonic elimination method was used to eliminate selected lower dominant harmonics resulting from the inverter switching action.

  16. Five-Level Z-Source Neutral Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Blaabjerg, Frede

    2007-01-01

    This paper proposes a five-level Z-source neutralpoint- clamped (NPC) inverter with two Z-source networks functioning as intermediate energy storages coupled between dc sources and NPC inverter circuitry. Analyzing the operational principles of Z-source network with partial dclink shoot......-through scheme reveals the hidden theories in the five-level Z-source NPC inverter unlike the operational principle appeared in the general two-level Z-source inverter, so that the five-level Z-source NPC inverter can be designed with the modulation of carrier-based phase disposition (PD) or alternative phase...

  17. Analysis of Magnetically-Coupled Impedance Source Three-Phase Four-Switch Inverters

    DEFF Research Database (Denmark)

    Li, Kerui; Abdelhakim, Ahmed; Yang, Yongheng

    2017-01-01

    In this paper, magnetically-coupled impedance source (MCIS) three-phase four-switch inverters are introduced for renewable energy applications. This inverter utilizes two single-phase MCIS inverters to obtain a three-phase output, where less component-count is achieved in order to reduce the inve......In this paper, magnetically-coupled impedance source (MCIS) three-phase four-switch inverters are introduced for renewable energy applications. This inverter utilizes two single-phase MCIS inverters to obtain a three-phase output, where less component-count is achieved in order to reduce...... the inverter volume. On the other hand, as a result of the reduced number of switches, the proposed inverter suffers from higher voltage stresses. The MCIS inverters are first reviewed. Then, the modulation and operation principle of the MCIS three-phase inverter topology are introduced before sizing...

  18. Japanese power electronics inverter technology and its impact on the American air conditioning industry

    Energy Technology Data Exchange (ETDEWEB)

    Ushimaru, Kenji.

    1990-08-01

    Since 1983, technological advances and market growth of inverter- driven variable-speed heat pumps in Japan have been dramatic. The high level of market penetration was promoted by a combination of political, economic, and trade policies in Japan. A unique environment was created in which the leading domestic industries-- microprocessor manufacturing, compressors for air conditioning and refrigerators, and power electronic devices--were able to direct the development and market success of inverter-driven heat pumps. As a result, leading US variable-speed heat pump manufacturers should expect a challenge from the Japanese producers of power devices and microprocessors. Because of the vertically-integrated production structure in Japan, in contrast to the out-sourcing culture of the United States, price competition at the component level (such as inverters, sensors, and controls) may impact the structure of the industry more severely than final product sales. 54 refs., 47 figs., 1 tab.

  19. Japanese power electronics inverter technology and its impact on the American air conditioning industry

    Science.gov (United States)

    Ushimaru, Kenji

    1990-08-01

    Since 1983, technological advances and market growth of inverter-driven variable-speed heat pumps in Japan have been dramatic. The high level of market penetration was promoted by a combination of political, economic, and trade policies in Japan. A unique environment was created in which the leading domestic industries, microprocessor manufacturing, compressors for air conditioning and refrigerators, and power electronic devices, were able to direct the development and market success of inverter-driven heat pumps. As a result, leading U.S. variable-speed heat pump manufacturers should expect a challenge from the Japanese producers of power devices and microprocessors. Because of the vertically-integrated production structure in Japan, in contrast to the out-sourcing culture of the United States, price competition at the component level (such as inverters, sensors, and controls) may impact the structure of the industry more severely than final product sales.

  20. Comparative study of SiC- and Si-based photovoltaic inverters

    Science.gov (United States)

    Ando, Yuji; Oku, Takeo; Yasuda, Masashi; Shirahata, Yasuhiro; Ushijima, Kazufumi; Murozono, Mikio

    2017-01-01

    This article reports comparative study of 150-300 W class photovoltaic inverters (Si inverter, SiC inverter 1, and SiC inverter 2). In these sub-kW class inverters, the ON-resistance was considered to have little influence on the efficiency. The developed SiC inverters, however, have exhibited an approximately 3% higher direct current (DC)-alternating current (AC) conversion efficiency as compared to the Si inverter. Power loss analysis indicated a reduction in the switching and reverse recovery losses of SiC metal-oxide-semiconductor field-effect transistors used for the DC-AC converter is responsible for this improvement. In the SiC inverter 2, an increase of the switching frequency up to 100 kHz achieved a state-of-the-art combination of the weight (1.25 kg) and the volume (1260 cm3) as a 150-250 W class inverter. Even though the increased switching frequency should cause the increase of the switching losses, the SiC inverter 2 exhibited an efficiency comparable to the SiC inverter 1 with a switching frequency of 20 kHz. The power loss analysis also indicated a decreased loss of the DC-DC converter built with SiC Schottky barrier diodes led to the high efficiency for its increased switching frequency. These results clearly indicated feasibility of SiC devices even for sub-kW photovoltaic inverters, which will be available for the applications where compactness and efficiency are of tremendous importance.

  1. Evidence that human papillomavirus causes inverted papilloma is sparse.

    Science.gov (United States)

    Justice, Jeb M; Davis, Kern M; Saenz, Daniel A; Lanza, Donald C

    2014-12-01

    Controversy exists regarding the pathogenesis of inverted papilloma as it relates to the involvement of human papillomavirus (HPV). The purpose of this report is to describe the prevalence of HPV in nondysplastic, "early inverted papilloma" and to summarize HPV detection rates in the general population and in other HPV related neoplasia. This case series report characterizes consecutive inverted papilloma patients from January 2005 to August 2012 with regard to smoking history, dysplasia, and HPV detection rates. Presence or absence of low/high risk HPV was determined by standardized in situ hybridization DNA probes. Medline literature review was performed to determine the prevalence of HPV in inverted papilloma without moderate or severe dysplasia. Thirty-six consecutive patients were identified with an average age of 63.6 (range, 40-84) years; gender: 23 men, 13 women. More than half (55%) were active or former smokers (14% active and 41% former). High/low risk HPV was present in 1 in 36 (2.7%) patients and 1 in 36 (2.7%) had mild dysplasia. In the literature review: (1) HPV was detected in 16.4% of inverted papilloma without dysplasia; (2) oral cavity HPV detection was 4.2% to 11.4% in the normal population; and (3) HPV was normally detected in 85% to 95% of HPV-related neoplasia. Given histological features of inverted papilloma and comparatively low detection rates of HPV in inverted papilloma without dysplasia (2.7%), as well as the summary of the world literature, HPV is not related to the initial pathogenesis of inverted papilloma or inverted papilloma's tendency to persist or recur. It is postulated that since inverted papilloma is more an inflammatory polyp, it is susceptible to secondary HPV infection because of its metaplasia. Tobacco and other causes of respiratory epithelium remodeling are more plausible explanations for the initial tissue transformation to inverted papilloma. © 2014 ARS-AAOA, LLC.

  2. Membrane fusion and inverted phases

    International Nuclear Information System (INIS)

    Ellens, H.; Siegel, D.P.; Alford, D.; Yeagle, P.L.; Boni, L.; Lis, L.J.; Quinn, P.J.; Bentz, J.

    1989-01-01

    We have found a correlation between liposome fusion kinetics and lipid phase behavior for several inverted phase forming lipids. N-Methylated dioleoylphosphatidylethanolamine (DOPE-Me), or mixtures of dioleoylphosphatidylethanolamine (DOPE) and dioleoylphosphatidylcholine (DOPC), will form an inverted hexagonal phase (HII) at high temperatures (above TH), a lamellar phase (L alpha) at low temperatures, and an isotropic/inverted cubic phase at intermediate temperatures, which is defined by the appearance of narrow isotropic 31 P NMR resonances. The phase behavior has been verified by using high-sensitivity DSC, 31 P NMR, freeze-fracture electron microscopy, and X-ray diffraction. The temperature range over which the narrow isotropic resonances occur is defined as delta TI, and the range ends at TH. Extruded liposomes (approximately 0.2 microns in diameter) composed of these lipids show fusion and leakage kinetics which are strongly correlated with the temperatures of these phase transitions. At temperatures below delta TI, where the lipid phase is L alpha, there is little or no fusion, i.e., mixing of aqueous contents, or leakage. However, as the temperature reaches delta TI, there is a rapid increase in both fusion and leakage rates. At temperatures above TH, the liposomes show aggregation-dependent lysis, as the rapid formation of HII phase precursors disrupts the membranes. We show that the correspondence between the fusion and leakage kinetics and the observed phase behavior is easily rationalized in terms of a recent kinetic theory of L alpha/inverted phase transitions. In particular, it is likely that membrane fusion and the L alpha/inverted cubic phase transition proceed via a common set of intermembrane intermediates

  3. Asymmetrical and symmetrical embedded Z-source inverters

    DEFF Research Database (Denmark)

    Gao, F.; Loh, P.C.; Li, D.

    2011-01-01

    ends, which indirectly translates to a lowering of overall system cost. These noted advantages are indeed appropriate for applications like photovoltaic and fuel cell energy harnessing, and have already been confirmed in simulation and experimentally using a laboratory-implemented inverter prototype.......This study presents two types of embedded Z-source inverters with each type further divided into asymmetrical and symmetrical realisations. Being different from their traditional counterparts, the presented inverters have their dc sources inserted within their X-shaped impedance networks so...

  4. Optimal Design of Modern Transformerless PV Inverter Topologies

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inverter design variables are derived for each PV inverter topology and installation site. The H5, H6, neutral point...... clamped, active-neutral point clamped and conergy-NPC PV inverters designed using the proposed optimization process feature lower levelized cost of generated electricity and lifetime cost, longer mean time between failures and inject more PV-generated energy into the electric grid than their nonoptimized......The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during...

  5. Development of inverter for elevator door control

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.K.; Choi, U.D.; Jung, M.K.; Choi, S.K. [HHI R and D Center (Korea, Republic of); Yun, J.H.; Han, S.B. [HELCO R and D Center (Korea, Republic of)

    1995-07-01

    Most of the elevator door controllers have been controlled by DC Motors as an actuator. Recently, The control system using AC induction motor and general purpose inverter has been applied to control of elevator door. But there are some difficulties in making use of this system, such as adjustment of door speed pattern, door open-close time, and security of passenger safety. In order to solve these problems, a special inverter has been developed with an encoder feedback. From the result of field-test, we proved that a special inverter with encoder feedback device has come to considerable effect. Until now about 1,200 sets of these inverters are operated in Korea and about 100 sets are operated in South-east Asia. (author). 3 refs., 10 figs., 3 tabs.

  6. Operational analysis and comparative evaluation of embedded Z-Source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    ) circuitry connected instead of the generic voltage source inverter (VSI) circuitry. Further proceeding on to the topological variation, parallel embedded Z-source inverters are presented with the detailed analysis of topological configuration and operational principles showing that they are the superior......This paper presents various embedded Z-source (EZ-source) inverters broadly classified as shunt or parallel embedded Z-source inverter. Being different from the traditional Z-source inverter, EZ-source inverters are constructed by inserting dc sources into the X-shaped impedance network so...... that the dc input current flows smoothly during the whole switching period unlike the traditional Z-source inverter. This feature is interesting when PV panels or fuel cells are assumed to power load since the continuous input current flow reduces control complexity of dc source and system design burden...

  7. Advanced Power Electronics and Smart Inverters | Grid Modernization | NREL

    Science.gov (United States)

    Advanced Power Electronics and Smart Inverters Advanced Power Electronics and Smart Inverters , into the electric distribution system requires advanced power electronics, or smart inverters, that . Contact Sudipta Chakraborty Power Electronics Team Lead sudipta.chakraborty@nrel.gov | 303-384-7093

  8. Thin type inverter for machine-room-less elevator; Machine roomless elevator yo usugata inverter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    In the elevator industry, a machine-room-less elevator, which does not necessitate a machine room usually installed on the roof, has come into the spotlight in the domain of low and intermediate speed elevators. The lack of a machine room, however, will necessarily limit the space for the installation of the traction motor and control panel. Fuji Electric Co., Ltd., in order to properly cope with the situation, has developed in cooperation with Fujitec Co., Ltd., a very thin type inverter installable on an elevator hall floor. The inverter, based on Fuji Electric's high-performance vector control inverter FRENIC5000VG5, is as thin as 100mm, and is available in three series up to 11kW. For the embodiment of such a thin structure, a cooling structure of Fuji Electric's own is employed, and prudence is exercised as required at many locations so that maintainability will not be impaired throughout the very thin control panel design. (translated by NEDO)

  9. Inverter Output Filter Effect on PWM Motor Drives of a Flywheel Energy Storage System

    Science.gov (United States)

    Santiago, Walter

    2004-01-01

    NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheel systems for small satellite energy storage and attitude control applications. One research and development area has been the minimization of the switching noise produced by the pulsed width modulated (PWM) inverter that drives the flywheel permanent magnet motor/generator (PM M/G). This noise can interfere with the flywheel M/G hardware and the system avionics hampering the full speed performance of the flywheel system. One way to attenuate the inverter switching noise is by placing an AC filter at the three phase output terminals of the inverter with the filter neutral point connected to the DC link (DC bus) midpoint capacitors. The main benefit of using an AC filter in this fashion is the significant reduction of the inverter s high dv/dt switching and its harmonics components. Additionally, common mode (CM) and differential mode (DM) voltages caused by the inverter s high dv/dt switching are also reduced. Several topologies of AC filters have been implemented and compared. One AC filter topology consists of a two-stage R-L-C low pass filter. The other topology consists of the same two-stage R-L-C low pass filter with a series connected trap filter (an inductor and capacitor connected in parallel). This paper presents the analysis, design and experimental results of these AC filter topologies and the comparison between the no filter case and conventional AC filter.

  10. Adaptation of a fuzzy controller’s scaling gains using genetic algorithms for balancing an inverted pendulum

    Directory of Open Access Journals (Sweden)

    Duka Adrian-Vasile

    2011-12-01

    Full Text Available This paper examines the development of a genetic adaptive fuzzy control system for the Inverted Pendulum. The inverted pendulum is a classical problem in Control Engineering, used for testing different control algorithms. The goal is to balance the inverted pendulum in the upright position by controlling the horizontal force applied to its cart. Because it is unstable and has a complicated nonlinear dynamics, the inverted pendulum is a good testbed for the development of nonconventional advanced control techniques. Fuzzy logic technique has been successfully applied to control this type of system, however most of the time the design of the fuzzy controller is done in an ad-hoc manner, and choosing certain parameters (controller gains, membership functions proves difficult. This paper examines the implementation of an adaptive control method based on genetic algorithms (GA, which can be used on-line to produce the adaptation of the fuzzy controller’s gains in order to achieve the stabilization of the pendulum. The performances of the proposed control algorithms are evaluated and shown by means of digital simulation.

  11. LCCT-derived three-level three-phase inverters

    DEFF Research Database (Denmark)

    Shults, Tatiana; Husev, Oleksandr; Blaabjerg, Frede

    2017-01-01

    Solutions for a family of the novel three-level neutral-point-clamped (NPC) inductor-capacitor-capacitor-transformer (LCCT)-derived three-phase inverters are described and compared. Component design guidelines and steady state analysis, current and voltage waveforms are given. The authors......' simulation results confirm the theoretical predictions. It was found that an asymmetrical three-level NPC LCCT-derived inverter with a single diode in the impedance source network is the most promising solution. Experimental results for an asymmetrical three-level NPC LCCT-derived inverter with a single...

  12. Advanced Energy Validated Photovoltaic Inverter Technology at NREL | Energy

    Science.gov (United States)

    Inverter Technology at NREL Advanced Energy Industries-NREL's first partner at the Energy Systems Integration Facility (ESIF)-validated its advanced photovoltaic (PV) inverter technology using the ESIF's computer screen in a laboratory, with power inverter hardware in the background Photo by Dennis Schroeder

  13. Photovoltaic power generating system; Sanso zetsuengata taiyoko inverter

    Energy Technology Data Exchange (ETDEWEB)

    Nojima, T; Nakashima, T; Muta, Y; Takase, K; Hirayama, K [Nishimu Electronics Industries Co. Ltd., Saga (Japan)

    1996-10-27

    Nishimu Electronics Industries Co., Ltd. has developed a new series of inverters of three phase photovoltaic power generating system with the output ranging from 10 kVA to 50 kVA. For these inverters, the inverter and the system interconnection protector were integrated to make them smaller, lighter and cheaper. Stand-alone operation function was also added. The DC input voltage ranges were between 240 and 400 V for the crystalline solar cell, and between 170 and 400 V for the amorphous one. From the viewpoint of control of inverters, the inverters are generally controlled by the voltage-type current control method during the interconnection operation, while they must be controlled by the voltage-type voltage control method during the stand-alone operation which is the same as the UPS usually operated alone. For the present inverters, two control circuits for the interconnection operation and for the stand-alone operation were prepared. The control circuits for interconnection and stand-alone operations were switched using a cam-operation switch for change-over of operation. The results of the system interconnection verification tests satisfied the criteria of Japan`s Electronic Products Test Center. 3 refs., 4 figs., 2 tabs.

  14. Accelerating development of advanced inverters :

    Energy Technology Data Exchange (ETDEWEB)

    Neely, Jason C.; Gonzalez, Sigifredo; Ropp, Michael; Schutz, Dustin

    2013-11-01

    The high penetration of utility interconnected photovoltaic (PV) systems is causing heightened concern over the effect that variable renewable generation will have on the electrical power system (EPS). These concerns have initiated the need to amend the utility interconnection standard to allow advanced inverter control functionalities that provide: (1) reactive power control for voltage support, (2) real power control for frequency support and (3) better tolerance of grid disturbances. These capabilities are aimed at minimizing the negative impact distributed PV systems may have on EPS voltage and frequency. Unfortunately, these advanced control functions may interfere with island detection schemes, and further development of advanced inverter functions requires a study of the effect of advanced functions on the efficacy of antiislanding schemes employed in industry. This report summarizes the analytical, simulation and experimental work to study interactions between advanced inverter functions and anti-islanding schemes being employed in distributed PV systems.

  15. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  16. Static Characteristics of the Ferroelectric Transistor Inverter

    Science.gov (United States)

    Mitchell, Cody; Laws, crystal; MacLeond, Todd C.; Ho, Fat D.

    2010-01-01

    The inverter is one of the most fundamental building blocks of digital logic, and it can be used as the foundation for understanding more complex logic gates and circuits. This paper presents the characteristics of an inverter circuit using a ferroelectric field-effect transistor. The voltage transfer characteristics are analyzed with respect to varying parameters such as supply voltage, input voltage, and load resistance. The effects of the ferroelectric layer between the gate and semiconductor are examined, and comparisons are made between the inverters using ferroelectric transistors and those using traditional MOSFETs.

  17. Distributed Storage Inverter and Legacy Generator Integration Plus Renewables Solution for Microgrids

    Science.gov (United States)

    2015-07-01

    inverter (advantage of short term storage) and enables microgrid upgrade of legacy generator assets (integration of inverter and generator controllers ...today. The storage inverter controls and hardware are also leveraged to provide an islanding inverter ( microgrid compatibility) for renewable...transiently rated inverters, integration with legacy generator controls , and microgrid compatible inverters for PV. Key system design drivers are lowering

  18. Low voltage ride-through of single-phase transformerless photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2013-01-01

    Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV...... discussed. The selected inverters are the full-bridge inverter with bipolar modulation, full-bridge inverter with DC bypass and the Highly Efficient and Reliable Inverter Concept (HERIC). A 1 kW single-phase grid-connected PV system is analyzed to verify the discussions. The tests confirmed that, although...

  19. Low Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2014-01-01

    Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV...... are also discussed. The selected inverters are the full-bridge inverter with bipolar modulation, full-bridge inverter with DC bypass and the Highly Efficient and Reliable Inverter Concept (HERIC). A 1 kW singlephase grid-connected PV system is analyzed to verify the discussions. The tests confirmed that...

  20. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  1. Design optimization of transformerless grid-connected PV inverters including reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    Of the Electricity (LCOE) generated during the PV system lifetime period is minimized. The LCOE is calculated also considering the failure rates of the components, which affect the reliability performance and lifetime maintenance cost of the PV inverter. A design example is presented, demonstrating that compared...... to the non-optimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE.......This paper presents a new methodology for optimal design of transformerless Photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal values and types of the PV inverter components are calculated such that the PV inverter Levelized Cost...

  2. Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    such that the PV inverter LCOE generated during the PV system lifetime period is minimized. The LCOE is also calculated considering the failure rates of the components, which affect the reliability performance and lifetime maintenance cost of the PV inverter. A design example is presented, demonstrating...... that compared to the nonoptimized PV inverter structures, the PV inverters designed using the proposed optimization methodology exhibit lower total manufacturing and lifetime maintenance cost and inject more energy into the electric-grid and by that minimizing LCOE.......This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated...

  3. Closed-loop waveform control of boost inverter

    DEFF Research Database (Denmark)

    Zhu, Guo Rong; Xiao, Cheng Yuan; Wang, Haoran

    2016-01-01

    The input current of single-phase inverter typically has an AC ripple component at twice the output frequency, which causes a reduction in both the operating lifetime of its DC source and the efficiency of the system. In this paper, the closed-loop performance of a proposed waveform control method...... to eliminate such a ripple current in boost inverter is investigated. The small-signal stability and the dynamic characteristic of the inverter system for input voltage or wide range load variations under the closed-loop waveform control method are studied. It is validated that with the closedloop waveform...... control, not only was stability achieved, the reference voltage of the boost inverter capacitors can be instantaneously adjusted to match the new load, thereby achieving improved ripple mitigation for a wide load range. Furthermore, with the control and feedback mechanism, there is minimal level of ripple...

  4. Distortion and regulation characterization of a Mapham inverter

    Science.gov (United States)

    Sundberg, Richard C.; Brush, Andrew S.; Button, Robert M.; Patterson, Alexander G.

    1989-01-01

    Output voltage Total Harmonic Distortion (THD) of a 20kHz, 6kVA Mapham resonant inverter is characterized as a function of its switching-to-resonant frequency ratio, f sub s/f sub r, using the EASY5 engineering analysis system. EASY5 circuit simulation results are compared with hardware test results to verify the accuracy of the simulations. The effects of load on the THD versus f sub s/f sub r ratio is investigated for resistive, leading, and lagging power factor load impedances. The effect of the series output capacitor on the Mapham inverter output voltage distortion and inherent load regulation is characterized under loads of various power factors and magnitudes. An optimum series capacitor value which improves the inherent load regulation to better than 3 percent is identified. The optimum series capacitor value is different than the value predicted from a modeled frequency domain analysis. An explanation is proposed which takes into account the conduction overlap in the inductor pairs during steady-state inverter operation, which decreases the effective inductance of a Mapham inverter. A fault protection and current limit method is discussed which allows the Mapham inverter to operate into a short circuit, even when the inverter resonant circuit becomes overdamped.

  5. A new Zero Voltage Switching three-level NPC inverter

    DEFF Research Database (Denmark)

    He, Ning; Chen, Yenan; Xu, Dehong

    2015-01-01

    A novel Zero Voltage Switching (ZVS) three-level NPC inverter topology using a new ZVS Space Vector Modulation (SVM) scheme is proposed. A detailed operation analysis of ZVS three-level NPC inverter is given. The ZVS condition of the proposed ZVS inverter is derived and it can be achieved of all...

  6. Voltage Balancing Control of Diode-Clamped Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    ŞCHIOP Adrian

    2013-10-01

    Full Text Available In this paper is developed a control scheme for mono-phase diode clamped inverter to achieve balancing voltages on inverter capacitors. First, it develops a control scheme without taking into account the need to balance voltage on two capacitors. It examines the effects on the output voltage inverter, and then it realizes two control schemes that will balance the voltages. The simulations of control schemes were performed in OrCAD Pspice.

  7. Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

    Science.gov (United States)

    MacLeod, Todd C.; Phillips, Thomas A.; Sayyah, Rana; Ho, Fat D.

    2009-01-01

    The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

  8. Simulation of Fuzzy Adaptive PI Controlled Grid Interactive Inverter

    Directory of Open Access Journals (Sweden)

    Necmi ALTIN

    2009-03-01

    Full Text Available In this study, a voltage source grid interactive inverter is modeled and simulated in MATLAB/Simulink. Inverter is designed as current controlled and a fuzzy-PI current controller used for the generation of switching pattern to shape the inverter output current. The grid interactive inverter consists of a line frequency transformer and a LC type filter. Galvanic isolation between the grid and renewable energy source is obtained by the line frequency transformer and LC filter is employed to filter the high frequency harmonic components in current waveform due to PWM switching and to reduce the output current THD. Results of the MATLAB/Simulink simulation show that inverter output current is in sinusoidal waveform and in phase with line voltage, and current harmonics are in the limits of international standards (

  9. Triple inverter pierce oscillator circuit suitable for CMOS

    Science.gov (United States)

    Wessendorf,; Kurt, O [Albuquerque, NM

    2007-02-27

    An oscillator circuit is disclosed which can be formed using discrete field-effect transistors (FETs), or as a complementary metal-oxide-semiconductor (CMOS) integrated circuit. The oscillator circuit utilizes a Pierce oscillator design with three inverter stages connected in series. A feedback resistor provided in a feedback loop about a second inverter stage provides an almost ideal inverting transconductance thereby allowing high-Q operation at the resonator-controlled frequency while suppressing a parasitic oscillation frequency that is inherent in a Pierce configuration using a "standard" triple inverter for the sustaining amplifier. The oscillator circuit, which operates in a range of 10 50 MHz, has applications for use as a clock in a microprocessor and can also be used for sensor applications.

  10. Integrated Inverter For Driving Multiple Electric Machines

    Science.gov (United States)

    Su, Gui-Jia [Knoxville, TN; Hsu, John S [Oak Ridge, TN

    2006-04-04

    An electric machine drive (50) has a plurality of inverters (50a, 50b) for controlling respective electric machines (57, 62), which may include a three-phase main traction machine (57) and two-phase accessory machines (62) in a hybrid or electric vehicle. The drive (50) has a common control section (53, 54) for controlling the plurality of inverters (50a, 50b) with only one microelectronic processor (54) for controlling the plurality of inverters (50a, 50b), only one gate driver circuit (53) for controlling conduction of semiconductor switches (S1-S10) in the plurality of inverters (50a, 50b), and also includes a common dc bus (70), a common dc bus filtering capacitor (C1) and a common dc bus voltage sensor (67). The electric machines (57, 62) may be synchronous machines, induction machines, or PM machines and may be operated in a motoring mode or a generating mode.

  11. An SCR inverter for electric vehicles

    Science.gov (United States)

    Latos, T.; Bosack, D.; Ehrlich, R.; Jahns, T.; Mezera, J.; Thimmesch, D.

    1980-01-01

    An inverter for an electric vehicle propulsion application has been designed and constructed to excite a polyphase induction motor from a fixed propulsion battery source. The inverter, rated at 35kW peak power, is fully regenerative and permits vehicle operation in both the forward and reverse directions. Thyristors are employed as the power switching devices arranged in a dc bus commutated topology. This paper describes the major role the controller plays in generating the motor excitation voltage and frequency to deliver performance similar to dc systems. Motoring efficiency test data for the controller are presented. It is concluded that an SCR inverter in conjunction with an ac induction motor is a viable alternative to present dc vehicle propulsion systems on the basis of performance and size criteria.

  12. Solution-Processed n-Type Graphene Doping for Cathode in Inverted Polymer Light-Emitting Diodes.

    Science.gov (United States)

    Kwon, Sung-Joo; Han, Tae-Hee; Kim, Young-Hoon; Ahmed, Towfiq; Seo, Hong-Kyu; Kim, Hobeom; Kim, Dong Jin; Xu, Wentao; Hong, Byung Hee; Zhu, Jian-Xin; Lee, Tae-Woo

    2018-02-07

    n-Type doping with (4-(1,3-dimethyl-2,3-dihydro-1H-benzoimidazol-2-yl)phenyl) dimethylamine (N-DMBI) reduces a work function (WF) of graphene by ∼0.45 eV without significant reduction of optical transmittance. Solution process of N-DMBI on graphene provides effective n-type doping effect and air-stability at the same time. Although neutral N-DMBI act as an electron receptor leaving the graphene p-doped, radical N-DMBI acts as an electron donator leaving the graphene n-doped, which is demonstrated by density functional theory. We also verify the suitability of N-DMBI-doped n-type graphene for use as a cathode in inverted polymer light-emitting diodes (PLEDs) by using various analytical methods. Inverted PLEDs using a graphene cathode doped with N-DMBI radical showed dramatically improved device efficiency (∼13.8 cd/A) than did inverted PLEDs with pristine graphene (∼2.74 cd/A). N-DMBI-doped graphene can provide a practical way to produce graphene cathodes with low WF in various organic optoelectronics.

  13. CT and MR findings of the inverted papilloma

    International Nuclear Information System (INIS)

    Lim, Seong Youb; Kim, Hak Jin; Lee, Jun Woo; Park, Jae Yeong; Lee, Sung Gap; Kim, Byung Soo; Roh, Hwan Jung; Baik, Seung Kook

    1997-01-01

    The purpose of this study is to describe the CT and MR findings of inverted papilloma and to determine the specific differential finding between inverted papilloma with and without coexisting malignancy. Twenty-two histopathologically proven inverted papillomas were included in this study ; in six patients there was coexisting malignancy. Twenty-two CT images and eight MR images were retrospectively reviewed. On CT images, the inverted papillomas were seen as unilateral sinonasal masses with bone remodeling (n=15) rather than bone destruction (n=1) and showed iso- or slightly high attenuation. Three of the six malignant cases showed aggressive bone destruction and widespread extension into the orbit, intracranial and buccal spaces, and pterygopalatine fossa. On MR images, the inverted papillomas (n=3) were iso- (n=2) or slightly high (n=1) in signal intensity in relation to muscle on T1-weighted images, and high (n=3) on T2-weighted images. Gadolinium enhanced images showed heterogenous moderate enhancement. In the cases of coexisting malignancy (n=5), the masses were iso- (n=5) on T1-weighted images, high (n=5) on T2-weighted images and also showed heterogenous moderate enhancement. Inverted papilloma should be considered in the differential diagnosis of a bulky unilateral nasal mass extending into the adjacent paranasal sinuses, especially in an elderly patient with chronic nasal obstruction. Although there were no specific differential findings in signal intensity and enhancement pattern on CT and MR images between benign and malignant inverted papilloma, aggressive bone destruction and widespread extension beyond the sinonasal cavity are findings which are highly suggestive of coexisting malignancy

  14. Automatic load sharing in inverter modules

    Science.gov (United States)

    Nagano, S.

    1979-01-01

    Active feedback loads transistor equally with little power loss. Circuit is suitable for balancing modular inverters in spacecraft, computer power supplies, solar-electric power generators, and electric vehicles. Current-balancing circuit senses differences between collector current for power transistor and average value of load currents for all power transistors. Principle is effective not only in fixed duty-cycle inverters but also in converters operating at variable duty cycles.

  15. Base drive for paralleled inverter systems

    Science.gov (United States)

    Nagano, S. (Inventor)

    1980-01-01

    In a paralleled inverter system, a positive feedback current derived from the total current from all of the modules of the inverter system is applied to the base drive of each of the power transistors of all modules, thereby to provide all modules protection against open or short circuit faults occurring in any of the modules, and force equal current sharing among the modules during turn on of the power transistors.

  16. A New N-Level Inverter Based on Z-NPC

    Directory of Open Access Journals (Sweden)

    E. Babaei

    2017-12-01

    Full Text Available First of all, in this paper, the topology and operation of the three-phase three-level Z-source inverter based on neutral-point-clamped (Z-NPC are studied. Moreover, different combinations of permissible switching states and control signals are explained for this inverter. In this paper, the topology of the three-phase three-level Z-NPC inverter is extended for an n-level state. Also, a combination of allowed switching states with relevant mathematical equations is presented for the proposed n-level Z-NPC inverter. In comparison with multilevel voltage-source inverters (only voltage-boost capability, the proposed multilevel Z-NPC inverter is a single-stage converter and it has a buck-boost capability of voltage. On the other hand, the control of two-stage converters compared to single-stage converters can be more difficult because of existing more active and passive components. In this paper, two new PWM control methods are also proposed for various multilevel Z-NPC inverters. One advantage of the proposed PWM control methods in comparison with conventional PWM control methods is maintaining the charge balance of the dc-link capacitors in neutral point. The correct performance of the proposed multilevel Z-NPC topology and PWM control methods are verified by the obtained results of analysis and simulations performed in the PSCAD software.

  17. Six transformer based asymmetrical embedded Z-source inverters

    DEFF Research Database (Denmark)

    Wei, Mo; Poh Chiang, Loh; Chi, Jin

    2013-01-01

    Embedded/Asymmetrical embedded Z-source inverters were proposed to maintain smooth input current/voltage across the dc source and within the impedance network, remain the shoot-through feature used to boost up the dc-link voltage without adding bulky filter at input side. This paper introduces a ...... a class of transformer based asymmetrical embedded Z-source inverters which keep the smooth input current and voltage while achieving enhanced voltage boost capability. The presented inverters are verified by laboratory prototypes experimentally....

  18. Designing a Smaller Power Inverter: the Google Littlebox Challenge - Text

    Science.gov (United States)

    Version | Energy Systems Integration Facility | NREL Designing a Smaller Power Inverter: the Google Littlebox Challenge - Text Version er Power Inverter: the Google Littlebox Challenge - Text Version Below is the text version for the Designing a Smaller Power Inverter: the Google Littlebox

  19. An inverter/controller subsystem optimized for photovoltaic applications

    Science.gov (United States)

    Pickrell, R. L.; Merrill, W. C.; Osullivan, G.

    1978-01-01

    Conversion of solar array dc power to ac power stimulated the specification, design, and simulation testing of an inverter/controller subsystem tailored to the photovoltaic power source characteristics. This paper discusses the optimization of the inverter/controller design as part of an overall Photovoltaic Power System (PPS) designed for maximum energy extraction from the solar array. The special design requirements for the inverter/controller include: (1) a power system controller (PSC) to control continuously the solar array operating point at the maximum power level based on variable solar insolation and cell temperatures; and (2) an inverter designed for high efficiency at rated load and low losses at light loadings to conserve energy. It must be capable of operating connected to the utility line at a level set by an external controller (PSC).

  20. An SCR inverter with an integral battery charger for electric vehicles

    Science.gov (United States)

    Thimmeach, D.

    1983-01-01

    The feasibility of incorporating an onboard battery charger into the inverter previously developed under a NASA contract is successfully demonstrated. The rated output power of the resulting isolated battery charger is 3.6 kW at 220 Vac with an 86 percent efficiency and a 95 percent power factor. Also achieved are improved inverter efficiency (from 90 to 93 percent at 15 kW motor shaft power), inverter peak power capability (from 26 to 34 kW), and reduced weight and volume of the combined inverter/charger package (47 kg, 49 x 44 x 24 cm). Some major conclusions are that using the inverter commutation circuitry to perform the battery charging function is advantageous, and that the input-commutated thyristor inverter has the potential to be an excellent inverter and battery charger for use in electric vehicle applications.

  1. Stable inverted polymer/fullerene solar cells using a cationic polythiophene modified PEDOT:PSS cathodic interface

    Energy Technology Data Exchange (ETDEWEB)

    Rider, David A.; Worfolk, Brian J.; Buriak, Jillian M. [Department of Chemistry, University of Alberta, Edmonton, Alberta (Canada); NRC National Institute for Nanotechnology, Edmonton, Alberta (Canada); Harris, Kenneth D.; Shahbazi, Kevin; Fleischauer, Michael D. [NRC National Institute for Nanotechnology, Edmonton, Alberta (Canada); Lalany, Abeed [Department of Electrical and Computer Engineering, University of Alberta, Edmonton (Canada); Brett, Michael J. [NRC National Institute for Nanotechnology, Edmonton, Alberta (Canada); Department of Electrical and Computer Engineering, University of Alberta, Edmonton (Canada)

    2010-08-09

    A cationic and water-soluble polythiophene [poly[3-(6-pyridiniumylhexyl)thiophene bromide](P3PHT{sup +}Br{sup -})] is synthesized and used in combination with anionic poly(3,4-ethylenedioxythiophene):poly(p-styrenesulfonate) (PEDOT:PSS){sup -} to produce hybrid coatings on indium tin oxide (ITO). Two coating strategies are established: i) electrostatic layer-by-layer assembly with colloidal suspensions of (PEDOT:PSS){sup -}, and ii) modification of an electrochemically prepared (PEDOT:PSS){sup -} film on ITO. The coatings are found to modify the work function of ITO such that it could act as a cathode in inverted 2,5-diyl-poly(3-hexylthiophene) (P3HT)/[6,6]-phenyl-C{sub 61}-butyric acid methyl ester (PCBM) polymer photovoltaic cells. The interfacial modifier created from the layer-by-layer assembly route is used to produce efficient inverted organic photovoltaic devices (power conversion efficiency {proportional_to}2%) with significant long-term stability in excess of 500 h. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  2. Inverter-based successive approximation capacitance-to-digital converter

    KAUST Repository

    Omran, Hesham; Alhoshany, Abdulaziz; Salama, Khaled N.

    2017-01-01

    offset voltage will result in signal-dependent and parasitic-dependent conversion errors, which necessitates an op-amp-based implementation. The inverter-based SAR CDC contemplated herein provides robust, energy-efficient, and fast operation. The inverter

  3. Efficiency analysis on a two-level three-phase quasi-soft-switching inverter

    DEFF Research Database (Denmark)

    Geng, Pan; Wu, Weimin; Huang, Min

    2013-01-01

    When designing an inverter, an engineer often needs to select and predict the efficiency beforehand. For the standard inverters, plenty of researches are analyzing the power losses and also many software tools are being used for efficiency calculation. In this paper, the efficiency calculation...... for non-conventional inverters with special shoot-through state is introduced and illustrated through the analysis on a special two-level three-phase quasi-soft-switching inverter. Efficiency comparison between the classical two-stage two-level three-phase inverter and the two-level three-phase quasi......-soft-switching inverter is carried out. A 10 kW/380 V prototype is constructed to verify the analysis. The experimental results show that the efficiency of the new inverter is higher than that of the traditional two-stage two- level three-phase inverter....

  4. Modeling Single-Phase PV HB-ZVR Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the PV H-bridge zero voltage rectifier (HB-ZVR) inverter connected to grid and good results are obtained. First, several common topologies of PV inverters are introduced. Then the unipolar PWM control strategy is described for PV HB-ZVR inverter. Third, PLECS is briefly...... introduced. Fourth, the modeling of PV HB-ZVR inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is very powerful tool to real power circuits and it is very easy to simulate LCL filter. They have also verified that the unipolar PWM control...... strategy is feasible to control the PV HB-ZVR inverter....

  5. 27-Level DC–AC inverter with single energy source

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2012-01-01

    Highlights: ► This paper reports a novel 27-level DC–AC inverter using only single renewable energy source. ► The efficiency of the inverter is very high. The output waveform is almost sinusoidal. ► The cost is low as the number of power switches required is only 12. - Abstract: A novel design of multilevel DC–AC inverter using only single renewable energy source is presented in this paper. The proposed approach enables multilevel output to be realised by a few cascaded H-bridges and a single energy source. As an illustration, a 27-level inverter has been implemented based on three cascaded H-bridges with a single energy source and two capacitors. Using the proposed novel switching strategy, 27 levels can be realized and the two virtual energy sources can be well regulated. Experimental results are included to demonstrate the effectiveness of the proposed inverter.

  6. Compensation techniques for non-linearities in H-bridge inverters

    Directory of Open Access Journals (Sweden)

    Daniel Zammit

    2016-12-01

    Full Text Available This paper presents compensation techniques for component non-linearities in H-bridge inverters as those used in grid-connected photovoltaic (PV inverters. Novel compensation techniques depending on the switching device current were formulated to compensate for the non-linearities in inverter circuits caused by the voltage drops on the switching devices. Both simulation and experimental results will be presented. Testing was carried out on a PV inverter which was designed and constructed for this research. Very satisfactory results were obtained from all the compensation techniques presented, however the exact compensation method was the most effective, providing the highest reduction in harmonics.

  7. LLCL-Filter Based Single-Phase Grid-Tied Aalborg Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; Feng, Shuangshuang; Ji, Junhao

    2014-01-01

    The Aalborg Inverter is a new type of high efficient DC/AC grid-tied inverter, where the input DC voltage can vary in a wide range. Compared with the LCL-filter, the LLCL-filter can save the total inductance for the conventional voltage source inverter. In this paper, an LLCL-filter based Aalborg...... Inverter is proposed and its character is illustrated through the small signal analysis in both “Buck” and “Buck-Boost” mode. From the modeling, it can be seen that the resonant inductor in the capacitor loop has not brought extra control difficulties, whereas more inductance in the power loop can be saved...

  8. Energy-Saving Inverter

    Science.gov (United States)

    Rippel, W. E.; Edwards, D. B.

    1984-01-01

    Commutation by field-effect transistor allows more efficient operation. High voltage field-effect transistor (FET) controls silicon controlled rectifiers (SCR's). Circuit requires only one capacitor and one inductor in commutation circuit: simpler, more efficient, and more economical than conventional inverters. Adaptable to dc-to-dc converters.

  9. Finishing report for the 'SolcelleInverter' project

    Energy Technology Data Exchange (ETDEWEB)

    Boekhoej Kjaer, S.

    2005-03-01

    The main objective for this research project was to develop an inverter for the AC module, where one PV module is equipped with its own dedicated inverter, and connected to the grid. A topology, among many different candidates, has been selected, based on analysis's. The inverter has been optimized in respect to cost, reliability, and efficiency, and a prototype has been build. (au)

  10. THE DETERMINATION OF DIFFUSION COEFFICIENT OF INVERT MATERIALS

    International Nuclear Information System (INIS)

    P. Heller and J. Wright

    2000-01-01

    The Engineered Barrier System (EBS) Testing Department is performing tests in the Department of Energy's Atlas Facility to evaluate the performance of various means for increasing the time for breakthrough of radionuclides from the waste package to the base of the invert. This includes testing various barriers in the invert as a means of increasing breakthrough time through the process of diffusion. A diffusion barrier may serve as an invert material for the emplacement drifts. The invert material may consist of crushed tuff from the repository excavation at Yucca Mountain or silica sand. The objective of this report is to determine the diffusion coefficient of the crushed tuff and silica sand invert materials specified by the EBS Testing Department. The laboratory derived information from the testing was used in the Nernst-Einstein equation (Jurinak et al. 1987, p. 626) to determine the diffusion coefficient of the invert material. This report transmits the results and describes the methodology and interpretation. The scope of this report is to determine the diffusion coefficients of the invert materials mentioned above using the centrifuge at UFA Ventures. Standard laboratory procedures, described in Section 2 of this report, were used. The diffusion coefficients are to be determined over a range of moisture contents. The report contains the diffusion coefficients calculated by the Nernst-Einstein equation (Jurinak et al. 1987, p. 626) that become a part of the Technical Database. Raw data is also included in the report, however this data does not become part of the Technical Database as per Section 3.23 of AP-SIII.3Q ''Submittal and Incorporation of Data to the Technical Data Management System''. A sieve analysis of the samples was not conducted as part of this report, but sieve analysis may be accomplished as part of other reports. Two samples of crushed tuff and two samples of silica sand were tested

  11. Comparison of three-phase three-level voltage source inverter with intermediate dc–dc boost converter and quasi-Z-source inverter

    DEFF Research Database (Denmark)

    Panfilov, Dmitry; Husev, Oleksandr; Blaabjerg, Frede

    2016-01-01

    This study compares a three-phase three-level voltage source inverter with an intermediate dc-dc boost converter and a quasi-Z-source inverter in terms of passive elements values and dimensions, semiconductor stresses, and overall efficiency. A comparative analysis was conducted with relative...

  12. Current Harmonics from Single-Phase Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    Environmental conditions and operational modes may significantly impact the distortion level of the injected current from single-phase grid-connected inverter systems, such as photovoltaic (PV) inverters, which may operate in cloudy days with a maximum power point tracking, in a non-unity power...... factor, or in the low voltage ride through mode with reactive current injection. In this paper, the mechanism of the harmonic current injection from grid-connected single-phase inverter systems is thus explored, and the analysis is conducted on single-phase PV systems. In particular, the analysis...... is focused on the impacts of the power factor and the feed-in grid current level on the quality of the feed-in grid current from single-phase inverters. As a consequence, an internal model principle based high performance current control solution is tailor-made and developed for single-phase grid-connected...

  13. An iterative method to invert the LTSn matrix

    Energy Technology Data Exchange (ETDEWEB)

    Cardona, A.V.; Vilhena, M.T. de [UFRGS, Porto Alegre (Brazil)

    1996-12-31

    Recently Vilhena and Barichello proposed the LTSn method to solve, analytically, the Discrete Ordinates Problem (Sn problem) in transport theory. The main feature of this method consist in the application of the Laplace transform to the set of Sn equations and solve the resulting algebraic system for the transport flux. Barichello solve the linear system containing the parameter s applying the definition of matrix invertion exploiting the structure of the LTSn matrix. In this work, it is proposed a new scheme to invert the LTSn matrix, decomposing it in blocks and recursively inverting this blocks.

  14. Work Station For Inverting Solar Cells

    Science.gov (United States)

    Feder, H.; Frasch, W.

    1982-01-01

    Final work station along walking-beam conveyor of solar-array assembly line turns each pretabbed solar cell over, depositing it back-side-up onto landing pad, which centers cell without engaging collector surface. Solar cell arrives at inverting work station collector-side-up with two interconnect tabs attached to collector side. Cells are inverted so that second soldering operation takes place in plain view of operator. Inversion protects collector from damage when handled at later stages of assembly.

  15. NRC Information No. 87-24: Operational experience involving losses of electrical inverters

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    The NRC case study report identified three potential failure mechanisms for inverters. One of these involves relatively high ambient temperature and/or humidity within inverter enclosures. This condition appears to result in accelerated aging of components that form a part of the inverter circuitry causing a significant reduction in component life expectancy and inverter loss. Another mechanism for inverter failure involves the electrical interconnecting and physical arrangements for the inverter circuitry components. In some installations, these arrangements are such that when certain components fail, other components also may fail or degrade. The third failure mechanism involves voltage spikes and perturbations. Many of the electrical loads in a plant have inductive characteristics. During plant operations that involve energizing and deenergizing these loads, voltage spikes and perturbations are generated. The solid-state devices in the inverter circuitry are sensitive to these voltage spikes, and this has resulted in component failure, blown fuses, and inverter losses. Additionally, secondary voltage perturbations caused by lighting strikes or switching surges can have an adverse effect on inverter operation

  16. Power inverter implementing phase skipping control

    Science.gov (United States)

    Somani, Utsav; Amirahmadi, Ahmadreza; Jourdan, Charles; Batarseh, Issa

    2016-10-18

    A power inverter includes a DC/AC inverter having first, second and third phase circuitry coupled to receive power from a power source. A controller is coupled to a driver for each of the first, second and third phase circuitry (control input drivers). The controller includes an associated memory storing a phase skipping control algorithm, wherein the controller is coupled to receive updating information including a power level generated by the power source. The drivers are coupled to control inputs of the first, second and third phase circuitry, where the drivers are configured for receiving phase skipping control signals from the controller and outputting mode selection signals configured to dynamically select an operating mode for the DC/AC inverter from a Normal Control operation and a Phase Skipping Control operation which have different power injection patterns through the first, second and third phase circuitry depending upon the power level.

  17. Design consideration of resonance inverters with electro-technological application

    Science.gov (United States)

    Hinov, Nikolay

    2017-12-01

    This study presents design consideration of resonance inverters with electro-technological application. The presented methodology was achieved as a result of investigations and analyses of different types and working regimes of resonance inverters, made by the author. Are considered schemes of resonant inverters without inverse diodes. The first harmonic method is used in the analysis and design. This method for the case of inverters with electro-technological application gives very good accuracy. This does not require the use of a complex and heavy mathematical apparatus. The proposed methodology is easy to use and is suitable for use in training students in power electronics. Authenticity of achieved results is confirmed by simulating and physical prototypes research work.

  18. Active Damping Techniques for LCL-Filtered Inverters-Based Microgrids

    DEFF Research Database (Denmark)

    Lorzadeh, Iman; Firoozabadi, Mehdi Savaghebi; Askarian Abyaneh, Hossein

    2015-01-01

    LCL-type filters are widely used in gridconnected voltage source inverters, since it provides switching ripples reduction with lower cost and weight than the L-type counterpart. However, the inclusion of LCL-filters in voltage source inverters complicates the current control design regarding system...... the different active damping approaches for grid-connected inverters with LCL filters, which are based on high-order filters and additional feedbacks methods. These techniques are analyzed and discussed in detail....... stability issues; because an inherent resonance peak appears due to zero impedance at that resonance frequency. Moreover, in grid-interactive low-voltage microgrids, the interactions among the LCL-filtered-based parallel inverters may result in a more complex multiresonance issue which may compromise...

  19. Impacts of PV Array Sizing on PV Inverter Lifetime and Reliability

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    . However, oversizing the PV array will increase the loading of PV inverters, which may have undesired influence on the PV inverter lifetime and reliability. In that case, it may result in a negative impact on the overall PV energy cost, due to the increased maintenance for the PV inverters. This paper...... evaluates the lifetime of PV inverters considering the PV array sizing and installation sites, e.g., Denmark and Arizona. The results reveal that the PV array sizing has a considerable impact on the PV inverter lifetime and reliability, especially in Denmark, where the average solar irradiance level...

  20. Model Predictive Control of Z-source Neutral Point Clamped Inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of Z-source Neutral Point Clamped (NPC) inverter. For illustration, current control of Z-source NPC grid-connected inverter is analyzed and simulated. With MPC’s advantage of easily including system constraints, load current, impedance network...... response are obtained at the same time with a formulated Z-source NPC inverter network model. Operation steady state and transient state simulation results of MPC are going to be presented, which shows good reference tracking ability of this method. It provides new control method for Z-source NPC inverter...

  1. Thermal hydraulic design of a hydride-fueled inverted PWR core

    International Nuclear Information System (INIS)

    Malen, J.A.; Todreas, N.E.; Hejzlar, P.; Ferroni, P.; Bergles, A.

    2009-01-01

    An inverted PWR core design utilizing U(45%, w/o)ZrH 1.6 fuel (here referred to as U-ZrH 1.6 ) is proposed and its thermal hydraulic performance is compared to that of a standard rod bundle core design also fueled with U-ZrH 1.6 . The inverted design features circular cooling channels surrounded by prisms of fuel. Hence the relative position of coolant and fuel is inverted with respect to the standard rod bundle design. Inverted core designs with and without twisted tape inserts, used to enhance critical heat flux, were analyzed. It was found that higher power and longer cycle length can be concurrently achieved by the inverted core with twisted tape relative to the optimal standard core, provided that higher core pressure drop can be accommodated. The optimal power of the inverted design with twisted tape is 6869 MW t , which is 135% of the optimally powered standard design (5080 MW t -determined herein). Uncertainties in this design regarding fuel and clad dimensions needed to accommodate mechanical loads and fuel swelling are presented. If mechanical and neutronic feasibility of these designs can be confirmed, these thermal assessments imply significant economic advantages for inverted core designs.

  2. Mobile Inverted Constructivism: Education of Interaction Technology in Social Media

    Science.gov (United States)

    Chai, Jia-Xiang; Fan, Kuo-Kuang

    2016-01-01

    The combination of social media and invert teaching is a new path to inverting interation technology education and reconstructing the curriculum of context. In this paper, based on the theory of constructivism learning, a model named Mobile Inverted Constructivism (MIC) is provided. Moreover, in view of the functional quality of social media in…

  3. Tensor product of left n-invertible operators

    Czech Academy of Sciences Publication Activity Database

    Duggal, B.P.; Müller, Vladimír

    2013-01-01

    Roč. 215, č. 2 (2013), s. 113-125 ISSN 0039-3223 R&D Projects: GA ČR GA201/09/0473 Institutional support: RVO:67985840 Keywords : Banach space * essentially left n- invertible operator * left n-invertible operator Subject RIV: BA - General Mathematics Impact factor: 0.630, year: 2013 http://journals.impan.pl/cgi-bin/doi?sm215-2-2

  4. Single phase inverter for a three phase power generation and distribution system

    Science.gov (United States)

    Lindena, S. J.

    1976-01-01

    A breadboard design of a single-phase inverter with sinusoidal output voltage for a three-phase power generation and distribution system was developed. The three-phase system consists of three single-phase inverters, whose output voltages are connected in a delta configuration. Upon failure of one inverter the two remaining inverters will continue to deliver three-phase power. Parallel redundancy as offered by two three-phase inverters is substituted by one three-phase inverter assembly with high savings in volume, weight, components count and complexity, and a considerable increase in reliability. The following requirements must be met: (1) Each single-phase, current-fed inverter must be capable of being synchronized to a three-phase reference system such that its output voltage remains phaselocked to its respective reference voltage. (2) Each single-phase, current-fed inverter must be capable of accepting leading and lagging power factors over a range from -0.7 through 1 to +0.7.

  5. Breaking Barriers to Low-Cost Modular Inverter Production & Use

    Energy Technology Data Exchange (ETDEWEB)

    Bogdan Borowy; Leo Casey; Jerry Foshage; Steve Nichols; Jim Perkinson

    2005-05-31

    The goal of this cost share contract is to advance key technologies to reduce size, weight and cost while enhancing performance and reliability of Modular Inverter Product for Distributed Energy Resources (DER). Efforts address technology development to meet technical needs of DER market protection, isolation, reliability, and quality. Program activities build on SatCon Technology Corporation inverter experience (e.g., AIPM, Starsine, PowerGate) for Photovoltaic, Fuel Cell, Energy Storage applications. Efforts focused four technical areas, Capacitors, Cooling, Voltage Sensing and Control of Parallel Inverters. Capacitor efforts developed a hybrid capacitor approach for conditioning SatCon's AIPM unit supply voltages by incorporating several types and sizes to store energy and filter at high, medium and low frequencies while minimizing parasitics (ESR and ESL). Cooling efforts converted the liquid cooled AIPM module to an air-cooled unit using augmented fin, impingement flow cooling. Voltage sensing efforts successfully modified the existing AIPM sensor board to allow several, application dependent configurations and enabling voltage sensor galvanic isolation. Parallel inverter control efforts realized a reliable technique to control individual inverters, connected in a parallel configuration, without a communication link. Individual inverter currents, AC and DC, were balanced in the paralleled modules by introducing a delay to the individual PWM gate pulses. The load current sharing is robust and independent of load types (i.e., linear and nonlinear, resistive and/or inductive). It is a simple yet powerful method for paralleling both individual devices dramatically improves reliability and fault tolerance of parallel inverter power systems. A patent application has been made based on this control technology.

  6. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence......, it has enhanced buck-boost functionality and low output voltage distortions compared to the traditional Z-source inverter; it has continuous input current which reduces the source stress and inverter noise; it also contains two built-in capacitors which can block the DC current in the transformer...... windings thus preventing the core from saturation; lowers the voltage stresses and power losses of inverter switches and reduces the sizes of filtering devices and as well as obtains better output performance compared to the original two-level Z-source inverters. A phase disposition pulse width modulation...

  7. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...

  8. FET commutated current-FED inverter

    Science.gov (United States)

    Rippel, Wally E. (Inventor); Edwards, Dean B. (Inventor)

    1983-01-01

    A shunt switch comprised of a field-effect transistor (Q.sub.1) is employed to commutate a current-fed inverter (10) using thyristors (SCR1, SCR2) or bijunction transistors (Q.sub.2, Q.sub.3) in a full bridge (1, 2, 3, 4) or half bridge (5, 6) and transformer (T.sub.1) configuration. In the case of thyristors, a tapped inverter (12) is employed to couple the inverter to a dc source to back bias the thyristors during commutation. Alternatively, a commutation power supply (20) may be employed for that purpse. Diodes (D.sub.1, D.sub.2) in series with some voltage dropping element (resistor R.sub.12 or resistors R.sub.1, R.sub.2 or Zener diodes D.sub.4, D.sub.5) are connected in parallel with the thyristors in the half bridge and transformer configuration to assure sharing the back bias voltage. A clamp circuit comprised of a winding (18) negatively coupled to the inductor and a diode (D.sub.3) return stored energy from the inductor to the power supply for efficient operation with buck or boost mode.

  9. Inverted annular flow experimental study

    International Nuclear Information System (INIS)

    De Jarlais, G.; Ishii, M.

    1985-04-01

    Steady-state inverted annular flow of Freon 113 in up flow was established in a transparent test section. Using a special inlet configuration consisting of long aspect-ratio liquid nozzles coaxially centered within a heated quartz tube, idealized inverted annular flow initial geometry (cylindrical liquid core surrounded by coaxial annulus of gas) could be established. Inlet liquid and gas flowrates, liquid subcooling, and gas density (using various gas species) were measured and varied systematically. The hydrodynamic behavior of the liquid core, and the subsequent downstream break-up of this core into slugs, ligaments and/or droplets of various sizes, was observed. In general, for low inlet liquid velocities it was observed that after the initial formation of roll waves on the liquid core surface, an agitated region of high surface area, with attendant high momentum and energy transfers, occurs. This agitated region appears to propagate downsteam in a quasi-periodic pattern. Increased inlet liquid flow rates, and high gas annulus flow rates tend to diminish the significance of this agitated region. Observed inverted annular flow (and subsequent downstream flow pattern) hydrodynamic behavior is reported, and comparisons are drawn to data generated by previous experimenters studying post-CHF flow

  10. Power Inverter Topologies for Photovoltaic Modules - A Review

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Pedersen, John Kim; Blaabjerg, Frede

    2002-01-01

    This review-paper focuses on the latest development of inverters for photovoltaic AC-Modules. The power range for these inverters is usually within 90 Watt to 500 Watt, which covers the most commercial photovoltaic-modules. Self-commutated inverters have replaced the grid-commutated ones. The same...... is true for the bulky low-frequency transformers versus the high-frequency transformers, which are used to adapt the voltage level. The AC-Module provides a modular design and a flexible behaviour in various grid conditions. It hereby opens the market for photovoltaic-power for everyone at a low cost due...

  11. Robustness analysis of the efficiency in PV inverters

    DEFF Research Database (Denmark)

    Pigazo, Alberto; Liserre, Marco; Blaabjerg, Frede

    2013-01-01

    topology and control strategy but also on the characteristics of the employed components. The aim of this paper is evaluate the effect of physical variations associated to the main components on the overall efficiency of PV inverters. It is concluded that a statistical evaluation of the power converter......During last years an increasing attention has been paid to the efficiency of grid-connected PV inverters. They are manufactured from a number of discrete components and by using a certain topology and control strategy. Hence, the performance of a certain PV inverter not only depends on the selected...

  12. PLTS Transformerless Tegangan 20 kV menggunakan Cascaded H-Bridge Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    ANGGARA BRAJAMUSTHI

    2018-03-01

    Full Text Available ABSTRAK Aplikasi dari inverter multilevel pada sistem Pusat Listrik Tenaga Surya (PLTS dapat menghilangkan kebutuhan terhadap transformator, sehingga dapat mengurangi biaya investasi, mengurangi kompleksitas instalasi dan menghilangkan rugi-rugi daya transformator. Pada penelitian ini, sebuah inverter dengan topologi Cascaded H-Bridge Multilevel Inverter dirancang agar mampu mengubah tegangan rendah DC dari beberapa Photovoltaic (PV array menjadi tegangan fasa-fasa 20 kV AC. Perancangan menghasilkan sebuah inverter 3 fasa 27-level dimana setiap level masing-masing memiliki PV array, DC-DC boost converter, H-bridge inverter, dan keluaran 3 fasa terhubung dengan filter LCL. Setiap komponen dari inverter dan sistem tersebut kemudian dimodelkan pada MATLAB Simulink untuk mensimulasikan kinerja dari setiap komponen dan sistem pada Standard Test Condition (STC dari modul PV. Pada keadaan STC, daya 3 fasa maksimum yang dapat dihasilkan adalah 1,716 MW atau 68,54% dari daya DC maksimum sebesar 2,5 MWp. Sistem dapat menghasilkan tegangan fasa-fasa keluaran sebesar 20 kV dengan Total Harmonic Distortion (THD di bawah 5%. Kata kunci: Pusat Listrik Tenaga Surya (PLTS, photovoltaic, Cascaded H-Bridge Multilevel Inverter ABSTRACT The application of Multilevel Inverter in a Photovoltaic Solar Power Plant system could eliminate the needs of step-up transformer, which will reduce the system investment cost, simplify the system installation and also eliminate power losses of the transformer. In this paper, an inverter design was proposed with Cascaded H-Bridge Multilevel Inverter topology that is capable of converting low voltage DC power from several PV arrays into 20 kV AC power. The design resulted a 3 phase 27-level inverter where each level in the inverter has its own photovoltaic array, DC-DC boost converter, H-bridge inverter, and the 3 phase output is connected to LCL filter. Each component of the Inverter and the system were then modelled in MATLAB

  13. Multiband Split-Ring Resonator Based Planar Inverted-F Antenna for 5G Applications

    Directory of Open Access Journals (Sweden)

    Muhammad Kamran Ishfaq

    2017-01-01

    Full Text Available 5G, the fifth generation of wireless communications, is focusing on multiple frequency bands, such as 6 GHz, 10 GHz, 15 GHz, 28 GHz, and 38 GHz, to achieve high data rates up to 10 Gbps or more. The industry demands multiband antennas to cover these distant frequency bands, which is a task much more challenging. In this paper, we have designed a novel multiband split-ring resonator (SRR based planar inverted-F antenna (PIFA for 5G applications. It is composed of a PIFA, an inverted-L parasitic element, a rectangular shaped parasitic element, and a split-ring resonator (SRR etched on the top plate of the PIFA. The basic PIFA structure resonates at 6 GHz. An addition of a rectangular shaped parasitic element produces a resonance at 15 GHz. The introduction of a split-ring resonator produces a band notch at 8 GHz, and a resonance at 10 GHz, while the insertion of an inverted-L shaped parasitic element further enhances the impedance bandwidth in the 10 GHz band. The frequency bands covered, each with more than 1 GHz impedance bandwidth, are 6 GHz (5–7 GHz, 10 GHz (9–10.8 GHz, and 15 GHz (14-15 GHz, expected for inclusion in next-generation wireless communications, that is, 5G. The design is simulated using Ansys Electromagnetic Suite 17 simulation software package. The simulated and the measured results are compared and analyzed which are generally in good agreement.

  14. dSPACE based adaptive neuro-fuzzy controller of grid interactive inverter

    International Nuclear Information System (INIS)

    Altin, Necmi; Sefa, İbrahim

    2012-01-01

    Highlights: ► We propose a dSPACE based neuro-fuzzy controlled grid interactive inverter. ► The membership functions and rule base of fuzzy logic controller by using ANFIS. ► A LCL output filter is designed. ► A high performance controller is designed. - Abstract: In this study, design, simulation and implementation of a dSPACE based grid interactive voltage source inverter are proposed. This inverter has adaptive neuro-fuzzy controller and capable of importing electrical energy, generated from renewable energy sources such as the wind, the solar and the fuel cells to the grid. A line frequency transformer and a LCL filter are used at the output of the grid interactive inverter which is designed as current controlled to decrease the susceptibility to phase errors. Membership functions and rule base of the fuzzy logic controller, which control the inverter output current, are determined by using artificial neural networks. Both simulation and experimental results show that, the grid interactive inverter operates synchronously with the grid. The inverter output current which is imported to the grid is in sinusoidal waveform and the harmonic level of it meets the international standards (4.3 < 5.0%). In addition, simulation and experimental results of the neuro-fuzzy and the PI controlled inverter are given together and compared in detail. Simulation and experimental results show that the proposed inverter has faster response to the reference variations and lower steady state error than PI controller.

  15. Three-level grid-connected photovoltaic inverter with maximum power point tracking

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2013-01-01

    Highlight: ► This paper reports a novel 3-level grid connected photovoltaic inverter. ► The inverter features maximum power point tracking and grid current shaping. ► The inverter can be acted as an active filter and a renewable power source. - Abstract: This paper presents a systematic way of designing control scheme for a grid-connected photovoltaic (PV) inverter featuring maximum power point tracking (MPPT) and grid current shaping. Unlike conventional design, only four power switches are required to achieve three output levels and it is not necessary to use any phase-locked-loop circuitry. For the proposed scheme, a simple integral controller has been designed for the tracking of the maximum power point of a PV array based on an improved extremum seeking control method. For the grid-connected inverter, a current loop controller and a voltage loop controller have been designed. The current loop controller is designed to shape the inverter output current while the voltage loop controller can maintain the capacitor voltage at a certain level and provide a reference inverter output current for the PV inverter without affecting the maximum power point of the PV array. Experimental results are included to demonstrate the effectiveness of the tracking and control scheme.

  16. Simulation and Study of Multilevel Inverter System Fed By Photovoltaic Source

    Directory of Open Access Journals (Sweden)

    Ali Abdulrazzak Jasim

    2018-01-01

    Full Text Available This paper proposes a simulation of Photovoltaic energy used to supply an induction motor with acomparison of two types of inverters.In general, the greater number of motorswhich"are used incommercial and industrial applicationsare"induction motors. To use PV source to run the induction motor, an interface circuits are used which are a dc-dc"converter and an inverter, the PV cell has nonlinear behavior,"adc-dc converter is used along with Maximum Power Point Tracker controllerto improve theefficiency by boosting the output voltage of the PV module and to match the load demand."The dc output voltage of PV modulethen"converted to AC, two types of inverter are presented, A conventional Voltage Source Inverter system and multilevel inverter system which employselective harmonic eliminationmethod fed three phase induction motor, these two types of inverters are simulated using Matlab/Simulink and their results are presented. The FFT spectrum is presented of the output currents to analyze the harmonics reduction, which shows that the"multilevel inverter is better than VSI system"according to harmonics reduction and increment in output voltage and power.

  17. Dual Z-Source Inverter With Three-Level Reduced Common-Mode Switching

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2007-01-01

    This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck......-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter....... Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays...

  18. Smart Inverter Control and Operation for Distributed Energy Resources

    Science.gov (United States)

    Tazay, Ahmad F.

    The motivation of this research is to carry out the control and operation of smart inverters and voltage source converters (VSC) for distributed energy resources (DERs) such as photovoltaic (PV), battery, and plug-in hybrid electric vehicles (PHEV). The main contribution of the research includes solving a couple of issues for smart grids by controlling and implementing multifunctions of VSC and smart inverter as well as improving the operational scheme of the microgrid. The work is mainly focused on controlling and operating of smart inverter since it promises a new technology for the future microgrid. Two major applications of the smart inverter will be investigated in this work based on the connection modes: microgrid at grid-tied mode and autonomous mode. In grid-tied connection, the smart inverter and VSC are used to integrate DER such as Photovoltaic (PV) and battery to provide suitable power to the system by controlling the supplied real and reactive power. The role of a smart inverter at autonomous mode includes supplying a sufficient voltage and frequency, mitigate abnormal condition of the load as well as equally sharing the total load's power. However, the operational control of the microgrid still has a major issue on the operation of the microgrid. The dissertation is divided into two main sections which are: 1. Low-level control of a single smart Inverter. 2. High-level control of the microgrid. The first part investigates a comprehensive research for a smart inverter and VSC technology at the two major connections of the microgrid. This involves controlling and modeling single smart inverter and VSC to solve specific issues of microgrid as well as improve the operation of the system. The research provides developed features for smart inverter comparing with a conventional voltage sourced converter (VSC). The two main connections for a microgrid have been deeply investigated to analyze a better way to develop and improve the operational procedure of

  19. MODELLING AND SIMULATION OF HIGH FREQUENCY INVERTER FOR INDUCTION HEATING APPLICATION

    OpenAIRE

    SACHIN S. BANKAR; Dr. PRASAD M. JOSHI

    2016-01-01

    This paper presents modelling and simulation of high frequency inverter for induction heating applications. Induction heating has advantages like higher efficiency, controlled heating, safety and pollution free therefore this technology is used in industrial, domestic and medical applications. The high frequency full bridge inverter is used for induction heating, also MOSFET is used as a switching device for inverter and the control strategy used for inverter is Bipolar PWM control. The size ...

  20. Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Jafarpour, Saber [University of California Santa-Barbara; Bullo, Francesco [University of California Santa-Barbara; Dhople, Sairaj V. [University of Minnesota

    2017-08-21

    Next-generation power networks will contain large numbers of grid-connected inverters satisfying a significant fraction of system load. Since each inverter model has a relatively large number of dynamic states, it is impractical to analyze complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model with lumped parameters for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. We show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as any individual inverter in the system. Numerical simulations validate the reduced-order model.

  1. A New Green Power Inverter for Fuel Cells

    DEFF Research Database (Denmark)

    Andersen, Gert Karmisholt; Klumpner, Christian; Kjær, Søren Bækhøj

    2002-01-01

    This paper presents a new grid connected inverter for fuel cells. It consists of a two stage power conversion topology. Since the fuel cell operates with a low voltage in a wide voltage range (25 V-45 V) this volt- age must be transformed to around 350-400 V in order to invert this dc power into ac...... power to the grid. The proposed converter consists of an isolated dc-dc converter cascaded with a single phase H-bridge inverter. The dc-dc converter is a current-fed push-pull converter. A new dedicated voltage mode startup procedure has been developed in order to limit the inrush current during...... startup. The inverter is controlled as a power factor controller with resistor emulation.Experimental results of converter efficiency, grid performance and fuel cell response are shown for a 1 kW prototype. The proposed converter exhibits a high efficiency in a wide power range (higher than 92...

  2. Control Aspects of a LCL Grid-Connected Green Power Inverter

    DEFF Research Database (Denmark)

    Kjær, Søren Bækhøj; Andersen, Gert Karmisholt; Klumpner, Christian

    2002-01-01

    A full-bridge inverter for interfacing the utility grid is developed for using in a Green Power Inverter application. The inverter is feed from an arbitrary green power source (fuel cell, photovoltaic, small wind turbine etc.) through a rectifier into the dc-link. In order to maintain a sinusoidal...... grid current with low harmonic distortion and a high power factor, the inverter is controlled to emulate a negative resistance towards the grid. The size of the emulated resistor is determined by the dc-link voltage controller, which tries to maintain a constant dc-link voltage. This is however...

  3. Distributed Storage Inverter and Legacy Generator Integration Plus Renewable Solution for Microgrids

    Science.gov (United States)

    2015-07-01

    Observation ................. 5 2.1.5 PV Inverter with Microgrid Controls .......................................................... 5 2.2 TECHNOLOGY... CONTROL OF PV POWER RAMP RATE FOR GENERATOR STABILITY ..................... 27 6.11 DEMONSTRATION 11: MICROGRID VOLTAGE SUPPORT FROM PV INVERTER...power delivery optimized storage, transiently rated inverters, integration with legacy generator controls , and microgrid compatible inverters for PV

  4. Optimal design of NPC and Active-NPC transformerless PV inverters

    DEFF Research Database (Denmark)

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2012-01-01

    Targeting at a cost-effective deployment of grid-connected PhotoVoltaic (PV) systems, this paper presents a new methodology for the optimal design of transformerless PV inverters, which are based on the Neutral Point Clamped (NPC) and the Active-Neutral Point Clamped (ANPC) topologies. The design...... optimization results demonstrate that a different set of optimal values of the PV inverter switching frequency and output filter components are derived for the NPC and ANPC topologies, respectively, as well as for each of the PV inverter installation sites under study. The NPC and ANPC PV inverter structures......, which are derived using the proposed design optimization methodology exhibit lower Levelized Cost Of generated Electricity (LCOE) and manufacturing cost and they are simultaneously capable to inject more energy into the electric grid than the corresponding non-optimized PV inverters. Thus, the proposed...

  5. Coupled-Inductor-Based Aalborg Inverter With Input DC Energy Regulation

    DEFF Research Database (Denmark)

    Wang, Houqing; Wu, Weimin; Chung, Henry Shu-hung

    2018-01-01

    Due to the global environmental issues and energy crisis, the injection of renewable energy sources (RESs) into the power system is continuously increasing. As the interface between RESs and power grid, grid-tied inverters using MOSFET switches, without traditional line frequency transformers, show...... some potential advantages, in terms of low cost, high efficiency, and lightweight and small size. Among several proposed configurations, the Aalborg inverter was proposed as a new family of high efficiency MOSFET-switch-based hybrid source inverters. For a conventional “half bridge” type Aalborg...... inverter, due to the imbalance of two independent dc sources, the input dc energies may not be fully utilized, which may reduce the efficiency of whole system. In order to extract the maximum energy from two independent dc sources, a coupled-inductor-based “half bridge” type Aalborg inverter is proposed...

  6. Fully patterned and low temperature transparent ZnO-based inverters

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Heredia, G. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Department of Materials Science and Engineering, University of Texas at Dallas (United States); Mejia, I.; Rivas-Aguilar, M.E.; Hernandez-Como, N. [Department of Materials Science and Engineering, University of Texas at Dallas (United States); Martinez-Landeros, V.H. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Department of Materials Science and Engineering, University of Texas at Dallas (United States); Aguirre-Tostado, F.S. [Centro de Investigación en Materiales Avanzados, Unidad Monterrey, México (Mexico); Quevedo-Lopez, M.A., E-mail: mquevedo@utdallas.edu [Department of Materials Science and Engineering, University of Texas at Dallas (United States)

    2013-10-31

    The fabrication and characterization of transparent logic inverters based on zinc oxide (ZnO) thin film transistors (TFTs) is reported. The inverters are fabricated using standard photolithographic techniques on glass substrates, and the entire fabrication process temperature is maintained < 100 °C, which render the devices suitable for flexible and transparent electronics applications. Pulsed laser deposition is used to deposit aluminum-doped zinc oxide and ZnO as electrode and active semiconductor materials, respectively. Electrical characterization for individual TFTs demonstrate mobilities of ∼ 10 cm{sup 2}/V-s, threshold voltages of 6 V, sub-threshold slopes of 630 mV/decade and I{sub ON}/I{sub OFF} ratios of 5 × 10{sup 6}. Films characterized by UV-Vis showed optical transmission > 80% in the visible spectrum. The inverters are analyzed with AC input signals at frequencies of 100 and 500 Hz. The AC response shows an average rise and fall time transitions of 0.65 and 0.44 ms, respectively. Measured inverters delay is in the order of 0.21 ms. - Highlights: • Logic inverters based on zinc oxide thin film transistors. • Inverters fabricated using temperatures below 100 °C and standard photolithography. • Transparent aluminum-doped zinc oxide as gate, drain and source electrodes. • Devices with total transmittance in the visible range above 80%. • AC inverter response up to 500 Hz.

  7. Fully patterned and low temperature transparent ZnO-based inverters

    International Nuclear Information System (INIS)

    Gutierrez-Heredia, G.; Mejia, I.; Rivas-Aguilar, M.E.; Hernandez-Como, N.; Martinez-Landeros, V.H.; Aguirre-Tostado, F.S.; Quevedo-Lopez, M.A.

    2013-01-01

    The fabrication and characterization of transparent logic inverters based on zinc oxide (ZnO) thin film transistors (TFTs) is reported. The inverters are fabricated using standard photolithographic techniques on glass substrates, and the entire fabrication process temperature is maintained < 100 °C, which render the devices suitable for flexible and transparent electronics applications. Pulsed laser deposition is used to deposit aluminum-doped zinc oxide and ZnO as electrode and active semiconductor materials, respectively. Electrical characterization for individual TFTs demonstrate mobilities of ∼ 10 cm 2 /V-s, threshold voltages of 6 V, sub-threshold slopes of 630 mV/decade and I ON /I OFF ratios of 5 × 10 6 . Films characterized by UV-Vis showed optical transmission > 80% in the visible spectrum. The inverters are analyzed with AC input signals at frequencies of 100 and 500 Hz. The AC response shows an average rise and fall time transitions of 0.65 and 0.44 ms, respectively. Measured inverters delay is in the order of 0.21 ms. - Highlights: • Logic inverters based on zinc oxide thin film transistors. • Inverters fabricated using temperatures below 100 °C and standard photolithography. • Transparent aluminum-doped zinc oxide as gate, drain and source electrodes. • Devices with total transmittance in the visible range above 80%. • AC inverter response up to 500 Hz

  8. Novel T-Z source inverter with high voltage gain and reduced transformer turn ratio

    DEFF Research Database (Denmark)

    Mostaan, Ali; Sharifi Malfejani, Saeed; Soltani, Mohsen

    2015-01-01

    Novel voltage source inverter based on the Z source inverter structure is introduced in this paper. In this new inverter, two inductors of the impedance network in conventional Z source inverter are replaced with two transformers or coupled inductors, but unlike the T-Z source inverter that it......'s voltage gain is raised with increasing the transformers turn ratio, the voltage gain in the proposed inverter is raised with lowering the transformer turn ratio. Therefore, transformers with lower turn ratio are required in the proposed inverter in compare with T- Z source inverter that can lead to lower...

  9. Inverter ratio failure detector

    Science.gov (United States)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  10. Stochastic p -Bits for Invertible Logic

    Science.gov (United States)

    Camsari, Kerem Yunus; Faria, Rafatul; Sutton, Brian M.; Datta, Supriyo

    2017-07-01

    Conventional semiconductor-based logic and nanomagnet-based memory devices are built out of stable, deterministic units such as standard metal-oxide semiconductor transistors, or nanomagnets with energy barriers in excess of ≈40 - 60 kT . In this paper, we show that unstable, stochastic units, which we call "p -bits," can be interconnected to create robust correlations that implement precise Boolean functions with impressive accuracy, comparable to standard digital circuits. At the same time, they are invertible, a unique property that is absent in standard digital circuits. When operated in the direct mode, the input is clamped, and the network provides the correct output. In the inverted mode, the output is clamped, and the network fluctuates among all possible inputs that are consistent with that output. First, we present a detailed implementation of an invertible gate to bring out the key role of a single three-terminal transistorlike building block to enable the construction of correlated p -bit networks. The results for this specific, CMOS-assisted nanomagnet-based hardware implementation agree well with those from a universal model for p -bits, showing that p -bits need not be magnet based: any three-terminal tunable random bit generator should be suitable. We present a general algorithm for designing a Boltzmann machine (BM) with a symmetric connection matrix [J ] (Ji j=Jj i) that implements a given truth table with p -bits. The [J ] matrices are relatively sparse with a few unique weights for convenient hardware implementation. We then show how BM full adders can be interconnected in a partially directed manner (Ji j≠Jj i) to implement large logic operations such as 32-bit binary addition. Hundreds of stochastic p -bits get precisely correlated such that the correct answer out of 233 (≈8 ×1 09) possibilities can be extracted by looking at the statistical mode or majority vote of a number of time samples. With perfect directivity (Jj i=0 ) a small

  11. Integration of Xantrex HY-100 Hybrid Inverter with an AC Induction Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Corbus, D.; Newcomb, C.; Friedly, S.

    2003-05-01

    Several issues must be addressed before solid-state inverters can be used in wind-diesel systems with larger wind turbines. This project addresses those issues by using a commercial hybrid inverter designed for PV-diesel systems and modifying the inverter for use with an AC induction wind turbine. Another approach would have entailed building an inverter specifically for use with an AC induction wind turbine, but that was beyond the scope of this project. The inverter chosen for this project was a Xantrex HY-100, an inverter designed for PV systems. The unit consists of an inverter/rectifier bridge, a generator interface contactor, a battery charge controller, a hybrid controller, and the associated control electronics. Details of the inverter may be found in Appendix A. A twofold approach was taken to integrating the existing inverter for use with an AC induction wind turbine: 1) development of a detailed model to model both steady-state and transient behavior of the system, and 2) modification and testing of the inverter with an induction wind turbine based on the modeling results. This report describes these two tasks.

  12. Design and fabrication of ZnO/TiO2-based thin-film inverter circuits using solution processing techniques

    International Nuclear Information System (INIS)

    Liau, Leo Chau-Kuang; Kuo, Juo-Wei; Chiang, Hsin-Ni

    2012-01-01

    Novel and cost-effective ceramic-based thin-film inverter circuits, based on two layers of TiO 2 and ZnO films to construct junction field-effect transistors (FETs), were designed and fabricated by solution coating techniques. The double layers of the sol–gel ZnO and TiO 2 films were coated and characterized as a diode according to the current–voltage performance. Two types of FETs, the p-channel (p-FET) and the n-channel (n-FET) devices, were produced using different coating sequences of ZnO and TiO 2 layers. Both of the transistor performances were evaluated by analyzing the source–drain current versus voltage (I ds –V ds ) data with the control of the gate voltage (V g ). The ZnO/TiO 2 -based inverter circuits, such as the complementary-FET device, were further fabricated using the integration of the p-FET and the n-FET. The voltage transfer characteristics of the inverters were estimated by the tests of the input voltage (V in ) versus the output voltage (V out ) for the thin-film inverter circuits. (paper)

  13. Microcontroller Based SPWM Single-Phase Inverter For Wind Power Application

    Directory of Open Access Journals (Sweden)

    Khin Ohmar Lin

    2017-04-01

    Full Text Available In this paper microcontroller based sinusoidal pulse width modulation SPWM single-phase inverter is emphasized to constant frequency conversion scheme for wind power application. The wind-power generator output voltage and frequency are fluctuated due to the variation of wind velocity. Therefore the AC output voltage of wind-generator is converted into DC voltage by using rectifier circuit and this DC voltage is converted back to AC voltage by using inverter circuit. SPWM technique is used in inverter to get nearly sine wave and reduce harmonic content. The rating of inverter is 500W single-phase 220V 50 Hz. The required SPWM timing pulses for the inverter are generated from the PIC16F877A microcontroller. Circuit simulation was done by using Proteus 7 Professional and MATLABR 2008 software. The software for microcontroller is implemented by using MPASM assembler.

  14. Proposed Novel Multiphase-Multilevel Inverter Configuration for Open-End Winding Loads

    DEFF Research Database (Denmark)

    Padamanaban, Sanjeevi Kumar; Wheeler, Patrick; Blaabjerg, Frede

    2016-01-01

    This paper presents a new multiphase-multilevel inverter configuration for open-winding loads and suitable for medium power (low-voltage/high-current) applications such as `More Electric Aircraft'. Modular structure comprised of standard dual three-phase voltage source inverter (VSI) along with one...... is developed in this work and overcomes the complexity of standard space vector modulations, easy for real implementation purposes in digital processors. Proposed six-phase multilevel inverter configuration generates multilevel outputs with benefit in comprises with standard multilevel inverter topologies...

  15. Remote Control of an Inverted Pendulum System for Intelligent Control Education

    Directory of Open Access Journals (Sweden)

    Seul Jung

    2011-08-01

    Full Text Available This paper presents a remote control task of an inverted pendulum system for intelligent control education. The inverted pendulum moving on the guided rail is required to maintain balancing while it follows the desired trajectory commanded remotely by a joystick operated by a user. Position commands for the inverted pendulum system are given by a joystick through the network. The inverted pendulum system is controlled by a neural network control method. The corresponding control results are confirmed through experimental studies.

  16. Resonance Interaction of Multi-Parallel Grid-Connected Inverters with LCL Filter

    DEFF Research Database (Denmark)

    Lu, Minghui; Wang, Xiongfei; Loh, Poh Chiang

    2017-01-01

    This letter investigates the resonance characteristics and stability problem caused by the interactions of multiparallel LCL-filtered inverters. Compared to single grid-connected inverter, the multiinverter system presents a more challenging resonance issue, where the inverter interactions may...... excite multiple resonances at various frequencies. This letter proposes a modeling and analysis method based on the current separation scheme. It reveals that an interactive resonant current that circulates between the paralleled three-phase inverters may arise, depending on the current distribution...

  17. Vacuum arc switched inverter tests at 2.5 MVA

    International Nuclear Information System (INIS)

    Miller, R.N.; Gilmour, A.S. Jr.

    1979-01-01

    A mathematical analysis of the unloaded vacuum arc switch (VAS) inverter is undertaken; a key element in this analysis is the assumption of a constant voltage drop of 50 volts across each VAS while it is conducting. From this analysis a constant VAS-voltage model is developed to explain the VAS inverter operation. A comparison of data obtained from laboratory tests of the inverter is made with data obtained from this model, and agreement is found to be within 10% for up to 15 alternations

  18. Buck-Boost Current-Source Inverters With Diode-Inductor Network

    DEFF Research Database (Denmark)

    Gao, Feng; Liang, Chao; Loh, Poh Chiang

    2009-01-01

    This paper presents a number of novel currentsource inverters (CSIs) with enhanced current buck-boost capability. By adding a unique diode-inductor network between the inverter circuitry and current-boost elements, the proposed buck-boost CSIs demonstrate a doubling of current-boost capability......, as compared with other recently reported buck-boost CSIs. For controlling the proposed CSIs, two modulation schemes are designed for achieving either optimized harmonic performance or minimized commutation count without influencing the inverter current buck-boost gain. These theoretical findings were...

  19. Solar Power Station Output Inverter Control Design

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2011-04-01

    Full Text Available The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system can be used as a generator and it shall deliver energy to the supply network. Each type of the application has different requirements on the converter and its control algorithm. But for all of them the one thing is common – the maximal efficiency. The paper focuses on design and simulation of the low power inverter that acts as output part of the whole converter. In the paper the design of the control algorithm of the inverter for both types of inverter application – for islanding mode and for operation on the supply grid – is discussed. Attention is also paid to the design of the output filter that should reduce negative side effects of the converter on the supply network.

  20. Pulse width modulation inverter with battery charger

    Science.gov (United States)

    Slicker, James M.

    1985-01-01

    An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a "flyback" DC-DC converter circuit for recharging the battery.

  1. Three-phase multilevel inverter configuration for open-winding high power application

    DEFF Research Database (Denmark)

    Sanjeevikumar, Padmanaban; Blaabjerg, Frede; Wheeler, Patrick William

    2015-01-01

    This paper work exploits a new dual open-winding three-phase multilevel inverter configuration suitable for high power medium-voltage applications. Modular structure comprised of standard three-phase voltage source inverter (VSI) along with one additional bi-directional semiconductor device (MOSFET...... for implementation purpose. Proposed dual-inverter configuration generates multilevel outputs with benefit includes reduced THD and dv/dt in comparison to other dual-inverter topologies. Complete model of the multilevel ac drive is developed with simple MSCFM modulation in Matlab/PLECs numerical software...

  2. Design and Implementation of 13 Levels Multilevel Inverter for Photovoltaic System

    Science.gov (United States)

    Subramani, C.; Dhineshkumar, K.; Palanivel, P.

    2018-04-01

    This paper approaches the appearing and modernization of S-Type PV based 13- level multilevel inverter with less quantity of switch. The current S-Type Multi level inverter contains more number of switches and voltage sources. Multilevel level inverter is a be understandable among the most gainful power converters for high power application and present day applications with reduced switches. The fundamental good arrangement of the 13-level multilevel inverter is to get ventured voltage from a couple of levels of DC voltages.. The controller gives actual way day and age to switches through driver circuit using PWM methodology. The execution assessment of proposed multilevel inverter is checked using MATLAB/Simulink. This is the outstanding among other techniquem appeared differently in relation to all other existing system

  3. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed [GE Global Research Center, Niskayuna, NY (United States)

    2015-10-27

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

  4. Solar-Based Boost Differential Single Phase Inverter | Eya | Nigerian ...

    African Journals Online (AJOL)

    Solar-Based Boost Differential Single Phase Inverter. ... Solar-based boost differential inverter is reduced down to 22.37% in closed loop system with the aid of Proportional –integral-Differential (PID) ... The dc power source is photovoltaic cell.

  5. Simulation of push-pull inverter using wide bandgap devices

    Science.gov (United States)

    Al-badri, Mustafa; Matin, Mohammed A.

    2016-09-01

    This paper discusses the use of wide bandgap devices (SiC-MOSFET) in the design of a push-pull inverter which provides inexpensive low power dc-ac inverters. The parameters used were 1200V SiC MOSFET(C2M0040120D) made by power company ROHM. This modeling was created using parameters that were provided from a device datasheet. The spice model is provided by this company to study the effect of adding this component on push-pull inverter ordinary circuit and compared results between SiC MOSFET and silicon MOSFET (IRFP260M). The results focused on Vout and Vmos stability as well as on output power and MOSFET power loss because it is a very crucial aspect on DC-AC inverter design. These results are done using the National Instrument simulation program (Multisim 14). It was found that power loss is better in the 12 and 15 vdc inverter. The Vout in the SIC MOSFET circuit shows more stability in the high current low resistance load in comparison to the Silicon MOSFET circuit and this will improve the overall performance of the circuit.

  6. Tri-State Current Source Inverter With Improved Dynamic Performance

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Wong, Chow Pang

    2008-01-01

    Traditional dc-ac current source inverter (CSI) has a right-half-plane (RHP) zero in its control-to-output transfer function. This RHP zero causes the inverter output to fall before rising when a step increase in command reference is required (commonly known as non-minimum-phase effect). To achieve...... a better dynamic response, this paper proposes the design of a tri-state CSI using only an additional semiconductor switch for introducing unique freewheeling states to the traditional six active and three null states of a CSI. With the freewheeling states inserted appropriately within the inverter state...... sequence, the inductive boosting and discharging intervals can be decoupled, allowing the RHP zero to be eliminated with only minor circuit modifications (high level control schemes like predictive and multiloop voltage/current control remain unchanged). The designed inverter can be controlled using...

  7. Performance analysis of samarium cobalt P.M. synchronous motor fed from PWM inverters

    International Nuclear Information System (INIS)

    Rahman, M.A.; Choudhury, M.A.

    1985-01-01

    This paper presents an analysis and performance of samarium cobalt permanent magnet (P.M.) synchronous motors fed from two types of voltage source pulse width modulated (PWM) inverters. The analysis and test results on the steady state performance of a P.M. motor fed from PWM inverters are presented. PWM inverters are used in variable voltage variable frequency applications to avoid a double conversion process of ordinary inverters. In drives, they are used for voltage and speed regulation of motors. Use of modulation technique in inverters also allow to eliminate or minimize selected harmonics from the inverter output voltage

  8. Etiological role of human papillomavirus infection for inverted papilloma of the bladder.

    Science.gov (United States)

    Shigehara, Kazuyoshi; Sasagawa, Toshiyuki; Doorbar, John; Kawaguchi, Shohei; Kobori, Yoshitomo; Nakashima, Takao; Shimamura, Masayoshi; Maeda, Yuji; Miyagi, Tohru; Kitagawa, Yasuhide; Kadono, Yoshifumi; Konaka, Hiroyuki; Mizokami, Atsushi; Koh, Eitetsu; Namiki, Mikio

    2011-02-01

    The status of human papillomavirus (HPV) infection in urothelial inverted papilloma was examined in the present study. Formalin-fixed and paraffin-embedded tissues from eight cases of inverted papilloma of the bladder were studied. The presence of HPV-DNA was examined by modified GP5/6+PCR using archival tissue sections by microdissection. HPV genotype was determined with a Hybri-Max HPV genotyping kit. Immunohistochemical analysis for p16-INK4a, mcm7, HPV-E4, and L1, and in situ hybridization for the HPV genome were performed. HPV was detected in seven of eight cases (87.5%) of inverted papilloma. Three cases were diagnosed as inverted papilloma with atypia, while the remaining five were typical cases. HPV-18 was detected in two cases, including one inverted papilloma with atypia, and HPV-16 was detected in four cases, including one inverted papilloma with atypia. Multiple HPV type infection was detected in one typical case and one atypical case. High-risk HPV was present in all HPV-positive cases. Cellular proteins, p16-INK4a and mcm7, which are surrogate markers for HPV-E7 expression, were detected in all HPV-positive cases, and their levels were higher in inverted papilloma with atypia than in typical cases. In contrast, HPV-E4 and L1, which are markers for HPV propagation, were observed in some parts of the typical inverted papilloma tissue. High-risk HPV infection may be one of the causes of urothelial inverted papilloma, and inverted papilloma with atypia may have malignant potential. 2010 Wiley-Liss, Inc.

  9. High-speed elevators controlled by inverters

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Yoshio; Takahashi, Hideaki; Nakamura, Kiyoshi; Kinoshita, Hiroshi

    1988-10-25

    The super-high-speed elevator with superiority to 300m/min of speed, requires both the large capacity power and wide range speed controls. Therefore, in order to materialize the smooth and quiet operation characteristics, by applying the inverter control, the low torque ripple control in the low frequency range and high frequency large capacity inverting for lowering the motor in noise are necessary with their being assured of reliability. To satisfy the above necessary items, together with the development of a sine wave pulse width and frequency modulation (PWM/PFM) control system, to more precisely enable the sine wave electric current control, and 3kHz switching power converter, using a 800A power transistor module, a supervoltage control circuit under the extraordinary condition was designed. As a result of commercializing a 360m/min super-high speed inverter elevator, the power source unit, due to the effect of high power factor, could be reduced by 30% in capacity and also the higher harmonic wave including ratio could be considerably lowered to the inferiority to 5%. 2 references, 7 figures, 1 table.

  10. Inverter drive of the motor for pellet chain and rotary shaft

    Energy Technology Data Exchange (ETDEWEB)

    Horie, Katsuzo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kobayashi, Chiaki

    1996-12-01

    On renewal of driving control board for main body system of tandem accelerator of JAERI (Japan Atomic Energy Research Institute), drive of pellet chain and rotary shaft (for electric power supply to high voltage terminal and others) was changed to inverter driving. It is main aim of this change to prevent from mechanical impact at driving. Here is described on some problems seemed to form on change to inverter driving and some attentions on future adaptation of inverter to accelerator system after simply considering execution of improvement of main body driving system. As a result, the following items were found: (1) To need to confirm a character of possibility to adapt the inverter driving due to many case of accelerators fabricated with imported motor. (2) To preferably adapt motor with forced insulation or exclusive motor for the inverter, especially on case of 400 V class, to prevent insulation deterioration formed at motor terminal of serge voltage caused by circuit constant. (3) To install serge voltage control filter at secondary side of the inverter in the case of 400 V class motor, which is expected to protect the inverter from mixing of the serge accompanying with discharge of the accelerator. (4) To make the wire length of the motor from the inverter as short as possible, if possible within 30 m. And, (5) to install the converter at control panel at place easy to exchange its cooling fan and electrolytic condenser. (G.K.)

  11. Electric machine and current source inverter drive system

    Science.gov (United States)

    Hsu, John S

    2014-06-24

    A drive system includes an electric machine and a current source inverter (CSI). This integration of an electric machine and an inverter uses the machine's field excitation coil for not only flux generation in the machine but also for the CSI inductor. This integration of the two technologies, namely the U machine motor and the CSI, opens a new chapter for the component function integration instead of the traditional integration by simply placing separate machine and inverter components in the same housing. Elimination of the CSI inductor adds to the CSI volumetric reduction of the capacitors and the elimination of PMs for the motor further improve the drive system cost, weight, and volume.

  12. Stability of Brillouin flow in planar, conventional, and inverted magnetrons

    International Nuclear Information System (INIS)

    Simon, D. H.; Lau, Y. Y.; Greening, G.; Wong, P.; Gilgenbach, R. M.; Hoff, B. W.

    2015-01-01

    The Brillouin flow is the prevalent flow in crossed-field devices. We systematically study its stability in the conventional, planar, and inverted magnetron geometry. To investigate the intrinsic negative mass effect in Brillouin flow, we consider electrostatic modes in a nonrelativistic, smooth bore magnetron. We found that the Brillouin flow in the inverted magnetron is more unstable than that in a planar magnetron, which in turn is more unstable than that in the conventional magnetron. Thus, oscillations in the inverted magnetron may startup faster than the conventional magnetron. This result is consistent with simulations, and with the negative mass property in the inverted magnetron configuration. Inclusion of relativistic effects and electromagnetic effects does not qualitatively change these conclusions

  13. Understanding and managing the effects of battery charger and inverter aging

    International Nuclear Information System (INIS)

    Gunther, W.; Aggarwal, S.

    1992-01-01

    An aging assessment of battery chargers and inverters was conducted under the auspices of the NRC's Nuclear Plant Aging Research (NPAR) Program. The intentions of this program are to resolve issues related to the aging and service wear of equipment and systems at operating reactor facilities and to assess their impact on safety. Inverters and battery chargers are used in nuclear power plants to perform significant functions related to plant safety and availability. The specific impact of a battery charger or inverter failure varies with plant configuration. Operating experience data have demonstrated that reactor trips, safety injection system actuations, and inoperable emergency core cooling systems have resulted from inverter failures; and dc bus degradation leading to diesel generator inoperability or loss of control room annunication and indication have resulted from battery and battery charger failures. For the battery charger and inverter, the aging and service wear of subcomponents have contributed significantly to equipment failures. This paper summarizes the data and then describes methods that can be used to detect battery charger and inverter degradation prior to failure, as well as methods to minimize the failure effects. In both cases, the managing of battery charger and inverter aging is emphasized. 5 refs

  14. Challenging Ubiquitous Inverted Files

    NARCIS (Netherlands)

    de Vries, A.P.

    2000-01-01

    Stand-alone ranking systems based on highly optimized inverted file structures are generally considered ‘the’ solution for building search engines. Observing various developments in software and hardware, we argue however that IR research faces a complex engineering problem in the quest for more

  15. Modeling of SVM Diode Clamping Three-Level Inverter Connected to Grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    PLECS is used to model the diode clamping three-level inverter connected to grid and good results are obtained. First the output voltage SVM is described for diode clamping three-level inverter with loads connected to Y. Then the output voltage SVM of diode clamping three-level inverter is simply...... analyzed with loads connected to △. But it will be further researched in the future. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping three-level inverter is briefly presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS...... is very powerful tool to real power circuits and it is very easy to simulate them. They have also verified that SVM control strategy is feasible to control the diode clamping three-level inverter....

  16. Magnetically coupled impedance-source inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Blaabjerg, Frede

    2012-01-01

    input-to-output gain, and the presence of an impedance network. The former means a high dc-link voltage, which can stress the semiconductor switches unnecessarily. The latter leads to increases in cost and size, which similarly are undesirable. To lessen these concerns, an interesting approach is to use...... magnetically coupled transformers or inductors to raise the gain and modulation ratio simultaneously, while reducing the number of passive components needed. A study of the approach is now presented to show how various existing magnetically coupled inverters can be derived by applying a generic methodology....... The same methodology is then applied to develop more magnetically coupled Z-source inverters with advantages that have not been identified in the literature. These findings have already been proven in experiments....

  17. Disturbance estimator based predictive current control of grid-connected inverters

    OpenAIRE

    Al-Khafaji, Ahmed Samawi Ghthwan

    2013-01-01

    ABSTRACT: The work presented in my thesis considers one of the modern discrete-time control approaches based on digital signal processing methods, that have been developed to improve the performance control of grid-connected three-phase inverters. Disturbance estimator based predictive current control of grid-connected inverters is proposed. For inverter modeling with respect to the design of current controllers, we choose the d-q synchronous reference frame to make it easier to understand an...

  18. Design Optimization of Transformerless Grid-Connected PV Inverters Including Reliability

    OpenAIRE

    Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    This paper presents a new methodology for optimal design of transformerless photovoltaic (PV) inverters targeting a cost-effective deployment of grid-connected PV systems. The optimal switching frequency as well as the optimal values and types of the PV inverter components is calculated such that the PV inverter LCOE generated during the PV system lifetime period is minimized. The LCOE is also calculated considering the failure rates of the components, which affect the reliability performance...

  19. Optimized Pulse Width Modulation for transformerless active-NPC inverters

    DEFF Research Database (Denmark)

    Achilladelis, Nikolaos; Koutroulis, Eftichios; Blaabjerg, Frede

    2014-01-01

    The transformerless DC/AC inverter topologies are employed in Photovoltaic systems in order to improve the power conversion efficiency, power density and cost. The Active-Neutral Point Clamped (Active-NPC) transformerless inverters have the advantage of achieving better thermal balance among thei...

  20. Multiple degree of freedom inverted pendulum dynamics: Modeling, computation, and experimentation

    Science.gov (United States)

    Chen, Cheng-Yuan Jerry

    A pendulum is statically unstable in its upright inverted state due to the Earth's gravitational attraction which points downward. However, with proper forcing, the pendulum can be stabilized in its upright inverted state. Special interest is on periodic vertical forcing applied to the pendulum's base to stabilize it around the upright inverted equilibrium. Many researchers have studied how to stabilize the system by varying various parameters, in particular its amplitude and frequency. Most have focused on the single degree of freedom inverted pendulum case, which with linear assumption can be described via Mathieu's equation. The system stability can then be characterized by Floquet theory. Our focus is on searching for the periodic solutions inside the linearly stable region of the pendulum's inverted state when the pendulum is under proper periodic forcing. Our research shows that under appropriate excitation by controlling the forcing amplitude and frequency, the pendulum can maintain certain periodic orbits around its inverted state which we characterize in a systematic way. In this thesis, we applied four different kinds of geometric realizations of the system response: system time traces, system phase portraits, three dimensional views of the system phase portrait as a function of input forcing, and the system's power spectral density diagram. By analyzing these four diagrams simultaneously, we characterize different kinds of multi-frequency periodic behavior around the pendulum's inverted state. To further discuss the effect of the nonlinearity, we applied perturbation techniques using the normalized forcing amplitude as a perturbation parameter to carry out the approximate periodic solutions on a single degree of freedom inverted pendulum nonlinear model. We also discuss the multiple degree of freedom inverted pendulum system. Both numerical simulation and experiments were performed and detailed comparisons are discussed. Our numerical simulations show

  1. A Comparison between Buck-Boost Inverter with and without Buffer Inductor

    Directory of Open Access Journals (Sweden)

    Purwadi Agus Darwito

    2012-05-01

    Full Text Available The electric vehicle inverter requires an induction motor drive with a high output of voltage and current to reduce the number of batteries used and in turn reduce the vehicle’s weight. In this paper compared two single Phase BuckBoost Inverter (SPBBI, that is between the SPBBI conventional topology with SPBBI new topology uses a buffer inductor. The results of comparison are expected that the new inverter topology can strengthen the voltage greater than the conventional inverter topology. The inverter’s components of capacitor and inductor were reconfigured. The circuit was simulated for various carrier and signal frequencies with various load. The simulation results of the proposed topology compared with the simulation results of conventional topologies commonly used in a variety of frequency and load values. It is shown that the output voltage and current can be strengthened significantly, with a value of more than five times of the output voltage compared to the conventional inverter. The new inverter topology is useful to be implemented for the electric vehicle.

  2. The CMOS Integration of a Power Inverter

    OpenAIRE

    Mannarino, Eric Francis

    2016-01-01

    Due to their falling costs, the use of renewable energy systems is expanding around the world. These systems require the conversion of DC power into grid-synchronous AC power. Currently, the inverters that carry out this task are built using discrete transistors. TowerJazz Semiconductor Corp. has created a commercial CMOS process that allows for blocking voltages of up to 700 V, effectively removing the barrier to integrating power inverters onto a single chip. This thesis explores this proce...

  3. Z-Source Inverter Based Power Quality Compensator with Enhanced Ride-Through Capability

    DEFF Research Database (Denmark)

    Gajanayake, C.J.; Vilathgamuwa, D.M.; Loh, P.C.

    2007-01-01

    Distributed generation has been gaining acceptance over the years and it has the potential to provide reliable power to sensitive loads. However, distributed networks are prone to unbalanced faults conditions. This makes single inverter DG systems unsuitable as UPS systems. This paper proposes...... a Zsource inverter based power quality compensator and a control structure that supplies high quality voltage to the connected sensitive load in the presence of other non linear loads. The proposed topology consists of combination of shunt and series inverters connected to a common Z-source impedance...... network. The shunt inverter is controlled to maintain a quality voltage waveform at the load bus. Whereas the series inverter enhances the ride-through capability during grid faults, protects the shunt inverter by limiting the current and also controls the power delivered to the grid. The performance...

  4. Study of Inverted Pendulum Robot Using Fuzzy Servo Control Method

    Directory of Open Access Journals (Sweden)

    Dazhong Wang

    2012-09-01

    Full Text Available The inverted pendulum robot is a classical problem in controls. The inherit instabilities in the setup make it a natural target for a control system. Inverted pendulum robot is suitable to use for investigation and verification of various control methods for dynamic systems. Maintaining an equilibrium position of the pendulum pointing up is a challenge as this equilibrium position is unstable. As the inverted pendulum robot system is nonlinear it is well-suited to be controlled by fuzzy logic. In this paper, Lagrange method has been applied to develop the mathematical model of the system. The objective of the simulation to be shown using the fuzzy control method can stabilize the nonlinear system of inverted pendulum robot.

  5. Single-stage MPPT control realization for Aalborg inverter in photovoltaic system

    DEFF Research Database (Denmark)

    Zhang, Shuai; Wu, Weimin; Wang, Houqing

    2017-01-01

    In this paper, the single-stage Maximum Power Point Tracking (MPPT) control strategy for the Aalborg photovoltaic inverter is presented. Aalborg inverter has many advantages, such as high efficiency, wide range of input voltage, minimum voltage drop of the filtering inductors, etc. Nevertheless......, it is essentially a “half-bridge” inverter with two input sources, where one source works in MPPT mode, the other is out of control. If without the reasonable parameter design and the proper control, the bus-voltage of this inverter may change greatly, resulting in the serious power oscillation around maximum power...

  6. Evaluation of Resonant Damping Techniques for Z-Source Current-Type Inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Gajanayake, C.J.

    2008-01-01

    For the renewable energy sources whose outputs vary continuously, a Z-source current-type inverter has been proposed as a possible buck-boost alternative for grid-interfacing. With a unique X-shaped LC network connected between its dc power source and inverter topology, Z-source current......-type inverter is however expected to suffer from compounded resonant complications in addition to those associated with its second-order output filter. To improve its damping performance, this paper proposes the careful integration of Posicast or three-step compensators before the inverter pulse-width modulator...... for damping triggered resonant oscillations. In total, two compensators are needed for wave-shaping the inverter boost factor and modulation ratio, and they can conveniently be implemented using first-in first-out stacks and embedded timers of modern digital signal processors widely used in motion control...

  7. Self-balanced modulation and magnetic rebalancing method for parallel multilevel inverters

    Science.gov (United States)

    Li, Hui; Shi, Yanjun

    2017-11-28

    A self-balanced modulation method and a closed-loop magnetic flux rebalancing control method for parallel multilevel inverters. The combination of the two methods provides for balancing of the magnetic flux of the inter-cell transformers (ICTs) of the parallel multilevel inverters without deteriorating the quality of the output voltage. In various embodiments a parallel multi-level inverter modulator is provide including a multi-channel comparator to generate a multiplexed digitized ideal waveform for a parallel multi-level inverter and a finite state machine (FSM) module coupled to the parallel multi-channel comparator, the FSM module to receive the multiplexed digitized ideal waveform and to generate a pulse width modulated gate-drive signal for each switching device of the parallel multi-level inverter. The system and method provides for optimization of the output voltage spectrum without influence the magnetic balancing.

  8. Reduced-Order Structure-Preserving Model for Parallel-Connected Three-Phase Grid-Tied Inverters: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Jafarpour, Saber [University of California, Santa Barbara; Bullo, Francesco [University of California, Santa Barbara; Dhople, Sairaj [University of Minnesota

    2017-08-31

    Given that next-generation infrastructures will contain large numbers of grid-connected inverters and these interfaces will be satisfying a growing fraction of system load, it is imperative to analyze the impacts of power electronics on such systems. However, since each inverter model has a relatively large number of dynamic states, it would be impractical to execute complex system models where the full dynamics of each inverter are retained. To address this challenge, we derive a reduced-order structure-preserving model for parallel-connected grid-tied three-phase inverters. Here, each inverter in the system is assumed to have a full-bridge topology, LCL filter at the point of common coupling, and the control architecture for each inverter includes a current controller, a power controller, and a phase-locked loop for grid synchronization. We outline a structure-preserving reduced-order inverter model for the setting where the parallel inverters are each designed such that the filter components and controller gains scale linearly with the power rating. By structure preserving, we mean that the reduced-order three-phase inverter model is also composed of an LCL filter, a power controller, current controller, and PLL. That is, we show that the system of parallel inverters can be modeled exactly as one aggregated inverter unit and this equivalent model has the same number of dynamical states as an individual inverter in the paralleled system. Numerical simulations validate the reduced-order models.

  9. A Transformer-less Single Phase Inverter For photovoltaic Systems

    DEFF Research Database (Denmark)

    Mostaan, Ali; Alizadeh, Ebrahim; Qu, Ying

    2017-01-01

    A single phase transformer-less inverter is introduced in this paper. The negative polarities of the input voltage and output terminal have common ground. Therefore, the leakage current problem that is common in PV systems is eliminated naturally. In addition, the proposed inverter has fewer comp...

  10. Voltage resonant inverter as a power source

    OpenAIRE

    Lupenko, Anatoliy; Stakhiv, Petro

    2014-01-01

    The operation mode of a voltage resonant inverter as a power source with variable load is analyzed. In order to reduce load power variations, an approach to development of the inverter’s load power response based on providing similar positive and negative power deviations from its nominal value has been proposed. The design procedure for resonant inverter with open loop structure as a power source has been elaborated. For a high pressure sodium lamp as a load, the power deviation of about 4% ...

  11. Improved Layout of Inverter for EMC Analysis

    OpenAIRE

    Yade , Ousseynou; Martin , Christian; Vollaire , Christian; Bréard , Arnaud; Ali , Marwan; Meuret , Régis; Hervé , Morel

    2017-01-01

    International audience; This paper details EMC (electromagnetic compatibility) analysis on an inverter application. The work deals with the whole power chain (±270Vdc input voltage to 3-phase 115 Vac output voltage). This inverter is composed by modular parts (power module and EMC filters) that supply motors in more electrical aircraft. Through our analysis an approach is defined to design a detailed lumped circuit model of the power module layout by using Q3D extractor and SABER software. Fr...

  12. Modelling of the modified-LLCL-filter-based single-phase grid-tied Aalborg inverter

    DEFF Research Database (Denmark)

    Liu, Zifa; Wu, Huiyun; Liu, Yuan

    2017-01-01

    Owing to less conduction and switching power losses, the recently proposed Aalborg inverter has high efficiency within a wide range of input DC voltage for single-phase DC/AC power conversion. In theory, the conduction power losses can be further decreased, if an LLCL-filter is adopted instead...... of an LCL-filter for a voltage source inverter, mainly due to the reduced inductance. The Aalborg inverter shows the characteristic of a current source inverter, when working in the `boost' state. Whether the LLCL-filter can meet the control requirement of this type inverter needs to be further explored....... In this study, the small signal analysis for the modified-LLCL-filter-based Aalborg inverter is addressed. Through the modelling, it can be proven that compared with the LCL-filter, the modified-LLCL-filter causes no extra control challenge for the Aalborg inverter, and therefore more inductance in the power...

  13. Reliability Assessment of Transformerless PV Inverters considering Mission Profiles

    Directory of Open Access Journals (Sweden)

    Yongheng Yang

    2015-01-01

    Full Text Available Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved by either modifying the modulation schemes or adding extra power switching devices, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redistributed and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature. The mission profile is translated to device thermal loading, which is used for lifetime prediction. Comparison results reveal the lifetime mismatches among the power switching devices operating under the same condition, which offers new thoughts for a robust design and a reliable operation of grid-connected transformerless PV inverters with high efficiency.

  14. Detecting and mitigating battery charger and inverter aging

    International Nuclear Information System (INIS)

    Gunther, W.E.; Lewis, R.; Subudhi, M.

    1988-08-01

    This report constitutes the second of the two-phase approach for assessing the safety and operational aspects of battery charger and inverter aging in nuclear power plants. This work, conducted by Brookhaven National Laboratory (BNL) under the auspices of the US NRC Nuclear Plant Aging Research (NPAR) Program, evaluated operating experience data, nuclear power plant maintenance practices, and plant design information to determine the impact of battery charger and inverter aging on safety, and the methods which should be used to detect aging degradation and mitigate its effects. A naturally aged inverter and battery charger were tested at BNL to evaluate the naturally aged condition, the effectiveness of condition monitoring techniques, and the practicality of implementing selected maintenance and monitoring recommendations. Temperature monitoring, component parameter measurements, and the periodic observation of critical circuit waveforms are viable methods for monitoring aging degradation. A maintenance program for battery chargers and inverters is recommended. As described in this report, the maintenance program incorporates inspection, monitoring, testing and repair activities which should be performed to detect and mitigate aging effects, and thereby assure the operational readiness of this important equipment throughout the plant's operating life. 32 refs., 43 figs., 19 tabs

  15. Mitigation of grid-current distortion for LCL-filtered grid-connected voltage-source inverter with inverter-side current control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    Due to the low inductance of an LCL-filter, the grid current generated by an LCL-filtered Voltage Source Inverter (VSI) is sensitive to low-order grid-voltage harmonics. This issue is especially tough for the control system with Inverter Current Feedback (ICF), because the grid-current harmonics...... can freely flow into the filter capacitor without control. To cope with this issue, this paper develops an approach for the ICF control system to suppress the grid-current harmonics without adding extra sensors. The proposed method applies harmonic controllers and feedforward scheme simultaneously...

  16. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  17. Fast Grid Frequency Support from Distributed Inverter-Based Resources

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson F [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-05-04

    This presentation summarizes power hardware-in-the-loop testing performed to evaluate the ability of distributed inverter-coupled generation to support grid frequency on the fastest time scales. The research found that distributed PV inverters and other DERs can effectively support the grid on sub-second time scales.

  18. Resistance Spot Welding with Middelfrequency-Inverter Weling Gun

    DEFF Research Database (Denmark)

    Rasmussen, Mogens H.

    The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun......The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun...

  19. Research on a Compound Control Strategy of Three-Phase Inverter for Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Yue Gaili

    2017-01-01

    Full Text Available To solve the problem of unbalanced output voltage of inverter under three-phase unbalanced load. In this paper, the main circuit topology using three-phase three-wire inverter topology. Established the mathematical model in several different coordinate system of the three-phase inverter. A compound control method is proposed by combining voltage current dual loop control method and repetitive control method, The control method is realized in three - phase 400 Hz inverter, and can meet the demand of unbalanced load to inverter, the reliability of the inverter circuit is improved. At the end of this paper, Matlab simulation analysis and experimental results are given, it is proved that the composite control method designed in this paper has a strong ability of unbalanced load.

  20. New Switched-Dual-Source Multilevel Inverter for Symmetrical and Asymmetrical Operation

    Directory of Open Access Journals (Sweden)

    Kennedy Adinbo Aganah

    2018-04-01

    Full Text Available The increasing integration of large solar PV and wind farms into the power grid has fueled, over the past two decades, growing demands for high-power, high-voltage, utility-scale inverters. Multilevel inverters have emerged as the industry’s choice for megawatt-range inverters because of their reduced voltage stress, capability for generating an almost-sinusoidal voltage, built-in redundancy and other benefits. This paper presents a novel switched-source multilevel inverter (SS MLI architecture. This new inverter shows superior capabilities when compared to existing topologies. It has reduced voltage stress on the semiconductor, uses fewer switches (i.e., reduced size/weight/cost and exhibits increased efficiency. The proposed SS MLI is comprised of two voltage sources ( V 1 , V 2 and six switches. It is capable of generating five-level output voltage in symmetric mode (i.e., V 1 = V 2 and seven-level output voltage in asymmetric mode (i.e., V 1 ≠ V 2 . We present simulations results (using MATLAB®/Simulink® for five- and seven-level output voltages, and they strongly support the validity of the proposed inverter. These positive results are further supported experimentally using a laboratory prototype.

  1. Inverted radiative hierarchy of quark masses

    International Nuclear Information System (INIS)

    Berezhiani, Z.G.; Rattazzi, R.

    1992-01-01

    Inverted radiative hierarchy of quark masses is investigated. The authors suggest that the mass hierarchy is first generated in a sector of heavy isosinglet fermions due to radiative effects and then projected in the inverted way to the usual quarks by means of a universal seesaw. The simple left-right symmetric gauge model is presented with the P- and CP-parities and the exact isotopical symmetry which are softly (or spontaneously) broken in the Higgs potential. This approach naturally explains the observed pattern of quark masses and mixing, providing the quantitatively correct formula for the Cabibbo angle. Top quark is predicted to be in the 90-150 GeV range

  2. Inverted Steam Generators for Sodium Cooled Fast Reactors

    International Nuclear Information System (INIS)

    Matal, Oldřich; Šimo, Tomáš; Matal, Oldřich Jr.

    2013-01-01

    Conclusions: Two inverted steam generators of the Czech industry provenience have still been in successful operation with no water into sodium leaks at BOR 60 (RIAR Dimitrovgrad, Russian Federation). Micromodular inverted steam generator (MMISG) since 1981 and modular inverted steam generator (MISG) since 1991. In the framework of the CP ESFR project predesign studies of 100 MW (thermal) ISG modules were performed with the consideration of MMISG and MISG design, operational and safety benefits and experience. Development of material and technology for sodium heated steam generators components reflecting contemporary domestic industrial conditions in the Czech Republic was restarted in the years 2003 to 2004 and supported in the years 2008 to 2011 by the European CP ESFR project and by the Ministry of Industry and Trade of the Czech Republic

  3. Acute proptosis: Unusual initial presentation of sinonasal inverted papilloma

    Institute of Scientific and Technical Information of China (English)

    Norihan Ibrahim; Baharuddin Abdullah; Regunath Kandasamy; Nor Hayati Othman; Mohtar Ibrahim; Adil Hussein

    2017-01-01

    Inverted papilloma is an uncommon histopathological finding of maxillary sinus tumor. We reported here a rare case of inverted papilloma of maxillary sinus presented initially with ipsilateral proptosis. A middle-aged lady with history of having allergic rhinitis presented with progressive left eye proptosis. Assessment revealed presence of orbital mass arising from paranasal sinus, in which the histopathological examination was initially inconclusive, and later it turned up to be inverted papilloma, partly with malignant transformation. High index of suspicion is necessary especially in those patients with recurrent non-specific sinonasal symptoms, which may need repeated biopsy and histopathological examination. Ocular manifestation signifies a more advance disease.

  4. Raman mediated all-optical cascadable inverter using silicon-on-insulator waveguides.

    Science.gov (United States)

    Sen, Mrinal; Das, Mukul K

    2013-12-01

    In this Letter, we propose an all-optical circuit for a cascadable and integrable logic inverter based on stimulated Raman scattering. A maximum product criteria for noise margin is taken to analyze the cascadability of the inverter. Variation of noise margin for different model parameters is also studied. Finally, the time domain response of the inverter is analyzed for different widths of input pulses.

  5. Two-motor single-inverter field-oriented induction machine drive ...

    Indian Academy of Sciences (India)

    Multi-machine, single-inverter induction motor drives are attractive in situations in which all machines are of similar ratings, and operate at approximately the same load torques. The advantages include small size compared to multi-inverter system, lower weight and overall cost. However, field oriented control of such drives ...

  6. Investigation of Pseudo-Active State in Z-Source Inverter

    DEFF Research Database (Denmark)

    Schaltz, Erik; Oprea, Octavian; Larsen, Lasse

    2005-01-01

    This paper introduces a new operating state of the Z-source inverter denoted the pseudo-active state. The pseudoactive state is a state that may boost the output voltage of the Zsource inverter to a level higher than expected. The influence of the pseudo-active state is investigated and an equation...

  7. FPGA Based Compensation Method for Correcting Distortion in Voltage Inverters

    National Research Council Canada - National Science Library

    Williamson, Kenya D

    2007-01-01

    ...) voltage source inverters. Blanking time distortion is caused by the delay inserted to prevent the short circuit that would occur if the two transistors in the same inverter leg are both on at the same time...

  8. Lower Side Switching Modification of SHEPWM for Single H-Bridge Unipolar Inverter

    Science.gov (United States)

    Aihsan, M. Z.

    2018-03-01

    Selective Harmonic Elimination Pulse Width Modulation (SHEPWM) is a famous fundamental frequency method for both single stage H-bridge inverter and cascaded multilevel inverters. The main function of SHEPWM is to eliminate the selective lower order of odd harmonic such 3rd, 5th 7th and 9th of the output voltage of the inverter but maintain the fundamental component. In this paper, the 5kHz of the unipolar SHEPWM switching scheme of the inverter is developed and later will be compared to the modified SHEPWM switching scheme. The performance of this inverter is measured through the final total harmonic distortion (THD), the efficiency of the whole system and the natural shape of the output after LC filter.

  9. A Coordinate Control Strategy for Circulating Current Suppression in Multiparalleled Three-Phase Inverters

    DEFF Research Database (Denmark)

    Zhang, Xueguang; Wang, Tianyi; Wang, Xiongfei

    2017-01-01

    This paper addresses the zero-sequence circulating current control in the multiparalleled three-phase voltage-source inverters. The model of the zero-sequence circulating current in the N-paralleled (N ≥ 3) inverters is derived. It is shown that the circulating current is not only susceptible...... to the mismatches of circuit parameters, but it is also influenced by the interactions of circulating current controllers used by other paralleled inverters. To eliminate these adverse effects on the circulating current control loop, a coordinate control strategy for the N-paralleled inverter is proposed based...... on the zero-vector feedforward method with the space-vector pulse width modulation. Moreover, a virtual inverter method is introduced to facilitate the implementation of the proposed controller, which decouples the interactions of circulating current controllers in the paralleled inverters. Finally...

  10. Comparative Evaluation of Pulsewidth Modulation Strategies for Z-Source Neutral-Point-Clamped Inverter

    DEFF Research Database (Denmark)

    Loh, P.C.; Blaabjerg, Frede; Wong, C.P.

    2007-01-01

    modulation (PWM) strategies for controlling the Z-source NPC inverter. While developing the PWM techniques, attention has been devoted to carefully derive them from a common generic basis for improved portability, easier implementation, and most importantly, assisting readers in understanding all concepts......Z-source neutral-point-clamped (NPC) inverter has recently been proposed as an alternative three-level buck-boost power conversion solution with an improved output waveform quality. In principle, the designed Z-source inverter functions by selectively "shooting through" its power sources, coupled...... to the inverter using two unique Z-source impedance networks, to boost the inverter three-level output waveform. Proper modulation of the new inverter would therefore require careful integration of the selective shoot-through process to the basic switching concepts to achieve maximal voltage-boost, minimal...

  11. Sine-wave three phase resonance inverter for operation of ...

    African Journals Online (AJOL)

    naeema

    conventional and simple solution to this requirement are in the following [8]. Using conventional H-bridge inverter beside of a step-up transformer. Using a renewable energy source with sufficiently large output voltage, which may be realized by a string of series connected modules followed by an H-bridge inverter [12], [13].

  12. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2013-01-01

    Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops and the mat......Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops...... control restores the frequency and amplitude deviations produced by the primary control. Also, a synchronization algorithm is presented in order to connect the MicroGrid to the grid. Experimental results are provided to validate the performance and robustness of the parallel VSI system control...

  13. Frequency scanning-based stability analysis method for grid-connected inverter system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion with conside......This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion...... with consideration of the inverter nonlinearities. Small current disturbance is injected into grid-connected inverter system in a particular frequency range, and the impedance is computed according to the harmonic-frequency response using Fourier analysis, and then the stability is predicted on the basis...... of the impedance stability criterion. The stability issues of grid-connected inverters with grid-current feedback and the converter-current feedback are addressed using the proposed method. The results obtained from simulation and experiments validate the effectiveness of the method. The frequency scanning...

  14. Experimental study of inverted-annular-flow hydrodynamics utilizing an adiabatic simulation

    International Nuclear Information System (INIS)

    De Jarlais, G.

    1983-03-01

    In experiments, inverted annular flow was simulated adiabatically with turbulent water jets, issuing downward from long aspect nozzles, enclosed in gas annuli. Velocities, diameters, and gas species were varied, and core jet length, shape, break-up mode, and dispersed-core droplet sizes were recorded at approximately 750 data points. Inverted annular flow was observed to develop into inverted slug flow at low relative velocities, and into dispersed droplet flow at high relative velocities. For both of the above transitions from inverted annular flow, correlations for core jet length were developed by extending work done on free liquid jets to include this new, coaxial, jet disintegration phenomenon. Jet break-up length is correlated as a function of jet diameter, jet Reynolds number, jet Weber number, void fraction, and gas Weber number. Correlations for core shape, break-up mechanisms and dispersed core droplet size for the case of transition to inverted slug flow were developed

  15. Transnasal endoscopic medial maxillectomy in recurrent maxillary sinus inverted papilloma.

    Science.gov (United States)

    Kamel, Reda H; Abdel Fattah, Ahmed F; Awad, Ayman G

    2014-12-01

    Maxillary sinus inverted papilloma entails medial maxillectomy and is associated with high incidence of recurrence. To study the impact of prior surgery on recurrence rate after transnasal endoscopic medial maxillectomy. Eighteen patients with primary and 33 with recurrent maxillary sinus inverted papilloma underwent transnasal endoscopic medial maxillectomy. Caldwell-Luc operation was the primary surgery in 12 patients, transnasal endoscopic resection in 20, and midfacial degloving technique in one. The follow-up period ranged between 2 to 19.5 years with an average of 8.8 years. Recurrence was detected in 8/51 maxillary sinus inverted papilloma patients (15.7 %), 1/18 of primary cases (5.5 %), 7/33 of recurrent cases (21.2 %); 3/20 of the transnasal endoscopic resection group (15%) and 4/12 of the Caldwell-Luc group (33.3%). Redo transnasal endoscopic medial maxillectomy was followed by a single recurrence in the Caldwell-Luc group (25%), and no recurrence in the other groups. Recurrence is more common in recurrent maxillary sinus inverted papilloma than primary lesions. Recurrent maxillary sinus inverted papilloma after Caldwell-Luc operation has higher incidence of recurrence than after transnasal endoscopic resection.

  16. New model of inverting substation for DC traction with regenerative braking system

    Science.gov (United States)

    Omar, Abdul Malek Saidina; Samat, Ahmad Asri Abd; Isa, Siti Sarah Mat; Shamsuddin, Sarah Addyani; Jamaludin, Nur Fadhilah; Khyasudeen, Muhammad Farris

    2017-08-01

    This paper presents a power electronic devices application focus on modeling, analysis, and control of switching power converter in the inverting DC substation with regenerative braking system which is used to recycle the surplus regenerative power by feed it back to the main AC grid. The main objective of this research is to improve the switching power electronic converter of the railway inverting substation and optimize the maximum kinetic energy recovery together with minimum power losses from the railway braking system. Assess performance including efficiency and robustness will be evaluated in order to get the best solution for the design configuration. Research methodology included mathematical calculation, simulation, and detail analysis on modeling of switching power converter on inverting substation. The design stage separates to four main areas include rectification mode, regenerative mode, control inverter mode and filtering mode. The simulation result has shown that the regenerative inverter has a capability to accept a maximum recovery power on the regeneration mode. Total energy recovery has increase and power losses have decreases because inverter abilities to transfer the surplus energy back to the main AC supply. An Inverter controller with PWM Generator and PI Voltage Regulator has been designed to control voltage magnitude and frequency of the DC traction system.

  17. Shunt Active-Power-Filter Topology Based on Parallel Interleaved Inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Asiminoaei, Lucian; Aeloiza, E.

    2008-01-01

    In this paper, an interleaved active-power-filter concept with reduced size of passive components is discussed. The topology is composed of two pulsewidth-modulation interleaved voltage-source inverters connected together on the ac line and sharing the same dc-link capacitor. The advantages......, because the power sharing allows one to use a higher switching frequency in each inverter. This paper analyzes the design of the passive components and gives a practical and low-cost solution for the minimization of the circulation currents between the inverters, by using common-mode coils. Several...

  18. State of the Art analysis for the 'SolcelleInverter' project. Optimised design and control of inverter for photovoltaic systems: the AC-module

    Energy Technology Data Exchange (ETDEWEB)

    Baekhoej Kjaer, S.

    2002-02-01

    The 'SolcelleInverter' project starts with this state-of-the-art analysis of 27 different inverter topologies for use in photovoltaic applications. The main concern is the present status for inverters for single solar modules. Technologies for larger clusters of modules are also investigated. The possibility of combining a small decentralised and a big centralised unit is as well investigated. A series of topologies are discovered and this paper will present them. That includes solutions with and without transformers, systems for one or multiple modules, commercial solutions and solutions found in scientific papers and patents. (au)

  19. Power inverter design for ASDEX Upgrade saddle coils

    Energy Technology Data Exchange (ETDEWEB)

    Teschke, M., E-mail: teschke@ipp.mpg.de [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany); Suttrop, W.; Rott, M. [Max Planck Institute for Plasma Physics, EURATOM Association, Boltzmannstr. 2, 85748 Garching (Germany)

    2013-10-15

    Highlights: ► A cost effective inverter topology for AUG's 16 in-vessel saddle coils has been found. ► Use of commercially available power modules is possible. ► Exchange of reactive power between multiple inverters is possible. ► Influence of electromagnetic noise to AUG's diagnostics was measured. ► Gas insulation of electric feed through significantly depends on magnetic fields. It is protected by fast turn-off circuit. -- Abstract: A set of 16 in-vessel saddle coils has been installed in the ASDEX Upgrade (AUG) experiment since the end of 2011 [1]. To achieve full performance, it is necessary to operate them with alternating current (AC) of arbitrary waveforms. To generate spatially resolved magnetic fields, it is required to allocate separate power inverters to every single coil. Therefore, different topologies are analyzed and compared. Studies of the commutation behavior of power stages, different pulse width modulation (PWM) schemes and single-phase-to-earth fault detection are executed. Experiments to evaluate the electromagnetic interference (EMI) of possible inverter topologies on the AUG diagnostics are done as well. A special focus is put on the feasibility of analyzed topologies using industrially available and fully assembled “power modules” to minimize development effort and costs.

  20. Electron-nuclear magnetic resonance in the inverted state

    International Nuclear Information System (INIS)

    Ignatchenko, V.A.; Tsifrinovich, V.I.

    1975-01-01

    The paper considers the susceptibility of the electron-nucleus system of a ferromagnet when nuclear magnetization is inverted with respect to the hyperfine field direction. The inverted state is a situation in which nuclear magnetization is turned through π relative to its equilibrium orientation, whereas electron magnetization is in an equilibrium state with respect to an external magnetic field. The consideration is carried out for a thin plate magnetized in its plane. Amplification of a weak radiofrequency signal can be attained under the fulfilment of an additional inequality relating the interaction frequency with electron and nuclear relaxation parameters. The gain may exceed the gain for an inverted nuclear system in magnetically disordered substances. In the range of strong interaction between the frequencies of ferromagnetic (FMR) and nuclear magnetic (NMR) resonances the electron-nuclear magnetic resonance (ENMR) spectrum possesses a fine structure which is inverse to that obtained for the ENMR spectrum in a normal state. The inverted state ENMR line shape is analysed in detail for the case of so weak HF fields that the relaxation conditions may be regarded as stationary. The initial (linear) stages of a forced transient process arising in an electron-nuclear system under the effect of a strong HF field are briefly analysed

  1. Does human papilloma virus play a role in sinonasal inverted papilloma?

    Science.gov (United States)

    Govindaraj, Satish; Wang, Hailun

    2014-02-01

    Inverted papillomas are a benign sinonasal tumor with a propensity for recurrence and malignant transformation. Although many investigations have been made into the nature of this disease, its etiology and causes for malignant transformation have yet to be fully elucidated. It is the authors' objective to present a review on management of the disease and evaluate the present relationship between human papilloma virus (HPV) and inverted papilloma. A causal relationship between HPV and the pathogenesis and progression of inverted papilloma has been posited since the 1980s. Although widely varied HPV detection rates have been reported, recent studies have noted a substantial increase in both recurrence and malignant transformation in HPV-infected inverted papillomas. However, exact cellular mechanisms by which infection leads to subsequent recurrence and development of carcinoma have yet to be elucidated. Evidence exists suggesting that HPV infection plays a role in the progression of inverted papilloma and confers an increased risk for recurrence and malignant transformation. PCR is the preferred detection method, and fresh or frozen specimens are the ideal source of tissue for evaluation. Although multiple studies have detected an association between HPV and inverted papilloma (both recurrent and malignant transformation), further studies are necessary to elucidate the underlying molecular pathways before an association can be changed to causation.

  2. Review of PV Inverter Technology Cost and Performance Projections

    Energy Technology Data Exchange (ETDEWEB)

    Navigant Consulting Inc.

    2006-01-01

    The National Renewable Energy Laboratory (NREL) has a major responsibility in the implementation of the U.S. Department of Energy's (DOE's) Solar Energy Technologies Program. Sandia National Laboratories (SNL) has a major role in supporting inverter development, characterization, standards, certifications, and verifications. The Solar Energy Technologies Program recently published a Multiyear Technical Plan, which establishes a goal of reducing the Levelized Energy Cost (LEC) for photovoltaic (PV) systems to $0.06/kWh by 2020. The Multiyear Technical Plan estimates that, in order to meet the PV system goal, PV inverter prices will need to decline to $0.25-0.30 Wp by 2020. DOE determined the need to conduct a rigorous review of the PV Program's technical and economic targets, including the target set for PV inverters. NREL requested that Navigant Consulting Inc.(NCI) conduct a review of historical and projected cost and performance improvements for PV inverters, including identification of critical barriers identified and the approaches government might use to address them.

  3. A Family of Cost-Effective Magnetically-Coupled Impedance Source Inverters

    DEFF Research Database (Denmark)

    Li, Kerui; Yang, Yongheng; Qin, Zian

    2017-01-01

    of required semiconductor switches is reduced. More important, the elimination of leakage currents makes it particularly suitable for high-efficiency photovoltaic (PV) applications. A comparison among prior-art PV inverters is then performed. The Performances of the inverters are evaluated analytically...

  4. A solution process for inverted tandem solar cells

    DEFF Research Database (Denmark)

    Larsen-Olsen, Thue Trofod; Bundgaard, Eva; Sylvester-Hvid, Kristian O.

    2011-01-01

    Tandem solar cells with normal and inverted device geometries were prepared by a solution process. Both device types were based on the use of zinc(II)oxide as the electron transporting layer (ETL). The hole transporting layer (HTL) was either PEDOT:PSS for normal geometry tandem solar cells...... or vanadium(V)oxide in the case of inverted tandem cells. It was found that the inverted tandem solar cells performed comparable or better than the normal geometry devices, showing that the connection structure of vanadium(V)oxide, Ag nanoparticles and zinc(II)oxide functions both as a good recombination...... layer, ensuring serial connection, and as a solvent barrier, protecting the first photoactive layer from processing of the second layer. This successfully demonstrates a tandem solar cell fabrication process fully compatible with state-of-the-art solution based automated production procedures....

  5. Analysis of Voltage Forming Methods for Multiphase Inverters

    Directory of Open Access Journals (Sweden)

    Tadas Lipinskis

    2013-05-01

    Full Text Available The article discusses advantages of the multiphase AC induction motor over three or less phase motors. It presents possible stator winding configurations for a multiphase induction motor. Various fault control strategies were reviewed for phases feeding the motor. The authors propose a method for quality evaluation of voltage forming algorithm in the inverter. Simulation of a six-phase voltage source inverter, voltage in which is formed using a simple SPWM control algorithm, was performed in Matlab Simulink. Simulation results were evaluated using the proposed method. Inverter’s power stage was powered by 400 V DC source. The spectrum of output currents was analysed and the magnitude of the main frequency component was at least 12 times greater than the next biggest-magnitude component. The value of rectified inverter voltage was 373 V.Article in Lithuanian

  6. Behandling af invert papillom med endonasal endoskopisk sinuskirurgi

    DEFF Research Database (Denmark)

    Andersen, Pia Juul; Kjeldsen, Anette Drøhse; Pedersen, Arne Toft

    2002-01-01

    INTRODUCTION: Inverted papilloma is a benign sinonasal tumour and has a marked tendency to recur after surgical excision. The tumour may be associated with malignancy and during growth it may destroy surrounding tissue. The treatment is either lateral rhinotomy or endoscopic sinus surgery. The aim...... of the study was to describe the course of all patients treated with endoscopic sinus surgery at the ENT Department at Vejle County Hospital during the period 1 January to 31 December 1999. MATERIAL AND METHODS: Twenty-eight journals of patients diagnosed with inverted nasal papillomas were reviewed...... with carcinoma. We did not see any serious side effects to the treatment. DISCUSSION: Endoscopic sinus surgery in combination with Caldwell-Luc can be recommended as an alternative treatment to lateral rhinotomy in patients with inverted papillomas. Preoperative staging with CT or MR-scanning, experienced...

  7. Modeling and analysis of energy quantization effects on single electron inverter performance

    Science.gov (United States)

    Dan, Surya Shankar; Mahapatra, Santanu

    2009-08-01

    In this paper, for the first time, the effects of energy quantization on single electron transistor (SET) inverter performance are analyzed through analytical modeling and Monte Carlo simulations. It is shown that energy quantization mainly changes the Coulomb blockade region and drain current of SET devices and thus affects the noise margin, power dissipation, and the propagation delay of SET inverter. A new analytical model for the noise margin of SET inverter is proposed which includes the energy quantization effects. Using the noise margin as a metric, the robustness of SET inverter is studied against the effects of energy quantization. A compact expression is developed for a novel parameter quantization threshold which is introduced for the first time in this paper. Quantization threshold explicitly defines the maximum energy quantization that an SET inverter logic circuit can withstand before its noise margin falls below a specified tolerance level. It is found that SET inverter designed with CT:CG=1/3 (where CT and CG are tunnel junction and gate capacitances, respectively) offers maximum robustness against energy quantization.

  8. An Enhanced Inverter Controller for PV Applications Using the dSPACE Platform

    Directory of Open Access Journals (Sweden)

    M. A. Hannan

    2010-01-01

    Full Text Available This paper presents the simulation modeling and prototype development of an inverter controller for photovoltaic (PV applications using the dSPACE DS1104 controller platform. The controller platform can link the simulation model developed in the MATLAB/SIMULINK environment to its prototype hardware. In the dSPACE controller, the voltage regulator controls the inverter by employing a proportional integral (PI controller and the Park transformation method to generate sinusoidal pulse-width modulation (SPWM signals. The SPWM signals switch the insulated gate bipolar transistor (IGBT to stabilize the 50-Hz sinusoidal AC output voltages of the inverter. The simulation was performed with a DC power supply that acts as the PV generator to supply the power to the inverter. The simulation model was then translated into the inverter prototype using the dSPACE platform and tested in the laboratory to prove the efficacy of the proposed controller. The experimental results for the inverter system demonstrated the feasibility of the proposed control strategy by maintaining the THD of the output voltage at 4.6%.

  9. Optimal Design of Modern Transformerless PV Inverter Topologies

    OpenAIRE

    Saridakis, Stefanos; Koutroulis, Eftichios; Blaabjerg, Frede

    2013-01-01

    The design optimization of H5, H6, neutral point clamped, active-neutral point clamped, and conergy-NPC transformerless photovoltaic (PV) inverters is presented in this paper. The components reliability in terms of the corresponding malfunctions, affecting the PV inverter maintenance cost during the operational lifetime period of the PV installation, is also considered in the optimization process. According to the results of the proposed design method, different optimal values of the PV inver...

  10. Grid-connected to/from off-grid transference for micro-grid inverters

    OpenAIRE

    Heredero Peris, Daniel; Chillón Antón, Cristian; Pages Gimenez, Marc; Gross, Gabriel Igor; Montesinos Miracle, Daniel

    2013-01-01

    This paper compares two methods for controlling the on-line transference from connected to stand-alone mode and vice versa in converters for micro-grids. The first proposes a method where the converter changes from CSI (Current Source Inverter) in grid-connected mode to VSI (Voltage Source Inverter) in off-grid. In the second method, the inverter always works as a non-ideal voltage source, acting as VSI, using AC droop control strategy.

  11. A modified two-level three-phase quasi-soft-switching inverter

    DEFF Research Database (Denmark)

    Liu, Yusheng; Wu, Weimin; Blaabjerg, Frede

    2014-01-01

    A traditional Voltage Source Inverter (VSI) has higher efficiency than a Current Voltage Source (CSI) due to the less conduction power loss. However, the reverse recovery of the free-wheeling diode limits the efficiency improvement for the silicon devices based hard-switching VSI. The traditional...... quasi-soft-switching inverter can alternate between VSI and CSI by using a proper control scheme and thereby reduce the power losses caused by the reverse recovery of the free-wheeling diode. Nevertheless, slightly extra conduction power loss of the auxiliary switch is also introduced. In order...... to reduce the extra conduction power loss and the voltage stress across the DC-link capacitor, a modified two-level three-phase quasi-soft-switching inverter is proposed by using a SiC MOSFET instead of an IGBT. The principle of the modified two-level three-phase quasi-soft-switching inverter is analyzed...

  12. An LLCL Power Filter for Single-Phase Grid-Tied Inverter

    DEFF Research Database (Denmark)

    Wu, Weimin; He, Yuanbin; Blaabjerg, Frede

    2012-01-01

    This paper presents a new topology of higher order power filter for grid-tied voltage-source inverters, named the LLCL filter, which inserts a small inductor in the branch loop of the capacitor in the traditional LCL filter to compose a series resonant circuit at the switching frequency. Particul......This paper presents a new topology of higher order power filter for grid-tied voltage-source inverters, named the LLCL filter, which inserts a small inductor in the branch loop of the capacitor in the traditional LCL filter to compose a series resonant circuit at the switching frequency...... to the inverter system control. The parameter design criteria of the proposed LLCL filter is also introduced. The comparative analysis and discussions regarding the traditional LCL filter and the proposed LLCL filter have been presented and evaluated through experiment on a 1.8-kW-single-phase grid-tied inverter...

  13. Argonne inverted sputter source

    International Nuclear Information System (INIS)

    Yntema, J.L.; Billquist, P.J.

    1983-01-01

    The emittance of the inverted sputter source with immersion lenses was measured to be about 5π mm mrad MeV/sup 1/2/ at the 75% level over a wide range of beam intensities. The use of the source in experiments with radioactive sputter targets and hydrogen loaded targets is described. Self contamination of the source is discussed

  14. Single DV-DXCCII Based Voltage Controlled First Order All-pass Filter with Inverting and Non-inverting responses

    Directory of Open Access Journals (Sweden)

    B Chaturvedi

    2015-12-01

    Full Text Available In this paper, a new voltage controlled first order all-pass filter is presented. The proposed circuit employs a single differential voltage dual-X second generation current conveyor (DV-DXCCII and a grounded capacitor only. The proposed all-pass filter provides both inverting and non inverting voltage-mode outputs from the same configuration simultaneously without any matching condition. Non-ideal analysis along with sensitivity analysis is also investigated. The proposed circuit has low active and passive sensitivities. As an application the proposed all-pass filter is connected in cascade to get higher order filter. The theoretical results are validated thorough PSPICE simulations using TSMC 0.18µm CMOS process parameters.

  15. Small-Signal Modeling and Analysis of Grid-Connected Inverter with Power Differential Droop Control

    Directory of Open Access Journals (Sweden)

    Xin Chen

    2016-01-01

    Full Text Available The conventional voltage and frequency droop control strategy in grid-connected inverter suffers a major setback in the presence of disturbance by producing oscillations. Adding a power differential term in droop controller is an effective way to address such drawback. In this paper, grid-connected inverter’s small-signal models of the conventional droop control and the power differential droop control are established. The eigenvalues of the models are then determined by system matrix. The eigenvalues analysis is presented which helps in identifying the relationship between the system stability and controller parameters. It is concluded that the damping ratio of dominant low-frequency eigenvalues increased and the oscillation caused by the disturbance is suppressed when a power differential term is added to the droop control method. The MATLAB/Simulink models of grid-connected inverter with both control strategies are also established to validate the results of small-signal analysis.

  16. Hawaiian Electric Advanced Inverter Grid Support Function Laboratory Validation and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Austin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Prabakar, Kumar [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lundstrom, Blake [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nepal, Shaili [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hoke, Anderson [National Renewable Energy Lab. (NREL), Golden, CO (United States); Asano, Marc [Hawaiian Electric Company, Honolulu, HI (United States); Ueda, Reid [Hawaiian Electric Company, Honolulu, HI (United States); Shindo, Jon [Hawaiian Electric Company, Honolulu, HI (United States); Kubojiri, Kandice [Hawaiian Electric Company, Honolulu, HI (United States); Ceria, Riley [Hawaiian Electric Company, Honolulu, HI (United States); Ifuku, Earle [Hawaiian Electric Company, Honolulu, HI (United States)

    2016-12-01

    The objective for this test plan was to better understand how to utilize the performance capabilities of advanced inverter functions to allow the interconnection of distributed energy resource (DER) systems to support the new Customer Self-Supply, Customer Grid-Supply, and other future DER programs. The purpose of this project was: 1) to characterize how the tested grid supportive inverters performed the functions of interest, 2) to evaluate the grid supportive inverters in an environment that emulates the dynamics of O'ahu's electrical distribution system, and 3) to gain insight into the benefits of the grid support functions on selected O'ahu island distribution feeders. These goals were achieved through laboratory testing of photovoltaic inverters, including power hardware-in-the-loop testing.

  17. High Quality Model Predictive Control for Single Phase Grid Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    Single phase grid-connected inverters with LCL filter are widely used to connect the photovoltaic systems to the utility grid. Among the presented control schemes, predictive control methods are faster and more accurate but are more complex to implement. Recently, the model-predictive control...... algorithm for single-phase inverter has been presented, where the algorithm implementation is straightforward. In the proposed approach, all switching states are tested in each switching period to achieve the control objectives. However, since the number of the switching states in single-phase inverter...... is low, the inverter output current has a high total harmonic distortions. In order to reduce the total harmonic distortions of the injected current, this paper presents a high-quality model-predictive control for one of the newest structure of the grid connected photovoltaic inverter, i.e., HERIC...

  18. A Novel Model Predictive Control for Single-Phase Grid-Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2017-01-01

    Single-phase grid-connected inverters with LCL filter are widely used to connect photovoltaic systems to the utility grid. Among the existing control schemes, predictive control methods are faster and more accurate but also more complicated to implement. Recently, the Model Predictive Control (MPC......) algorithm for single-phase inverter has been presented, where the algorithm implementation is straightforward. In the MPC approach, all switching states are considered in each switching period to achieve the control objectives. However, since the number of switching states in single-phase inverters is small......, the inverter output current has a high Total Harmonic Distortions (THD). In order to reduce this, this paper presents an improved MPC for single-phase grid-connected inverters. In the proposed approach, the switching algorithm is changed and the number of the switching states is increased by means of virtual...

  19. Lifetime Evaluation of PV Inverters considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2017-01-01

    The PV inverter lifetime is affected by the installed sites related to different solar irradiance and ambient temperature profiles. In fact, the installation site also affects the PV panel degradation rate, and thus the long-term power production. Prior-art lifetime analysis in PV inverters has...... not yet investigated the impact of panel degradation. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and installation sites. Evaluations have been carried out on PV systems installed in Denmark and Arizona. The results reveal that the PV panel degradation rate...... has a considerable impact on the PV inverter lifetime, especially in the hot climate (e.g., Arizona), where the panel degrades at a faster rate. In that case, the PV inverter lifetime estimation can be deviated by 54%, if the impact of PV panel degradation is not taken into account....

  20. Reliability consideration of low-power-grid-tied inverter for photovoltaic application

    OpenAIRE

    Liu, J.; Henze, N.

    2009-01-01

    In recent years PV modules have been improved evidently. An excellent reliability has been validated corresponding to Mean Time between Failure (MTBF) between 500 and 6000 years respectively in commercial utility power systems. Manufactures can provide performance guarantees for PV modules at least for 20 years. If an average inverter lifetime of 5 years is assumed, it is evident that the overall reliability of PV systems [PVSs] with integrated inverter is determined chiefly by the inverter i...

  1. Methods for the Optimal Design of Grid-Connected PV Inverters

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    and the efficient processing of this power by the DC/AC inverter. In this paper two new methods are presented for the optimal design of a PV inverter power section, output filter and MPPT control strategy. The influences of the electric grid regulations and standards as well as the PV array operational......The DC/AC inverters are used in grid-connected PV energy production systems as the power processing interface between the PV energy source and the electric grid. The energy injected into the electric grid by the PV installation depends on the amount of power extracted from the PV power source...

  2. Analysis and Design of Solar Photo voltaic Grid Connected Inverter

    Directory of Open Access Journals (Sweden)

    Muddasani Satyanarayana

    2015-08-01

    Full Text Available This paper presents common mode voltage analysis of single phase grid connected photovoltaic inverter. Many researchers proposed different grid tie inverters for applications like domestic powering, street lighting, water pumping, cooling and heating applications, however traditional grid tie PV inverter uses either a line frequency or a high frequency transformer between the inverter and grid but losses will increase in the network leading to reduced efficiency of the system. In order to increase the efficiency, with reduced size and cost of the system, the effective solution is to remove the isolation transformer. But common mode (CM ground leakage current due to parasitic capacitance between the PV panels and the ground making the system unreliable. The common mode current reduces the efficiency of power conversion stage, affects the quality of grid current, deteriorate the electric magnetic compatibility and give rise to the safety threats. In order to eliminate the common mode leakage current in Transformerless PV systm two control algorithms of multi-carrier pwm are implemented and compared for performance analysis.The shoot-through issue that is encountered by traditional voltage source inverter is analyzed for enhanced system reliability. These control algorithms are compared for common mode voltage and THD comparisons. The proposed system is designed using MATLAB/SIMULINK software for analysis.

  3. Dead-Time Generation in Six-Phase Frequency Inverter

    Directory of Open Access Journals (Sweden)

    Aurelijus Pitrėnas

    2016-06-01

    Full Text Available In this paper control of multi-phase induction drives is discussed. Structure of six-phase frequency inverter is examined. The article deals with dead-time generation circuits in six-phase frequency inverter for transistor control signals. Computer models of dead-time circuits is created using LTspice software package. Simulation results are compared with experimental results of the tested dead-time circuits. Parameters obtained in simulation results are close to the parameters obtained in experimental results.

  4. Active control of flying capacitor currents in multilevel voltage-source inverters

    Czech Academy of Sciences Publication Activity Database

    Kokeš, Petr; Semerád, Radko

    2013-01-01

    Roč. 58, č. 4 (2013), s. 393-410 ISSN 0001-7043 Institutional support: RVO:61388998 Keywords : voltage source inverter (VSI) * multilevel inverter * flying capacitor Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  5. Is radical surgery of an inverted papilloma of the maxillary sinus obsolete? a case report

    Directory of Open Access Journals (Sweden)

    Vedat Yildirim

    2016-12-01

    Full Text Available Abstract Background Sinonasal inverted papilloma is a locally aggressive tumor arising from the Schneiderian membrane which lines the nasal cavity and paranasal sinuses. Aggressive surgical approaches, such as lateral rhinotomy, were used until recently for complete removal of the inverted papilloma. Currently, endoscopic resection is the gold standard in the treatment of inverted papilloma. However, there are situations that justify an open approach. For example there are studies that report a higher postoperative recurrence rate after endonasal endoscopic resection, particularly in the treatment of recurrent diseases. While endoscopic resection performed by an experienced surgeon is definitely a minimally invasive therapy, an open approach is not necessarily associated with functional and aesthetic disadvantages. This case report describes the treatment of inverted papilloma by an open approach. This has been described before but the new gold standard of endoscopic resection has to be taken into account before any treatment decision is made nowadays. Case presentation Contrast-enhanced magnetic resonance imaging of the head and neck area was indicated in a 72-year-old white German man who presented with suspected squamous cell carcinoma of his lower lip. Magnetic resonance imaging additionally revealed a 3×2 cm2 polycyclic arranged mucosal thickening with cystic and solid contrast affine shares at the antral laterocaudal area of his right maxillary sinus, extending from his right lateral nasal wall to his maxillary sinus floor. He received antral polypectomy with medial maxillectomy via a unilateral LeFort I osteotomy approach. His pterygoid plate was preserved. A histological examination demonstrated a tumor composed of hyperplastic squamous epithelium protruding into the stroma (surface epithelial cells grew downward into the underlying supportive tissue, thus producing a grossly convoluted cerebriform appearance. Two weeks later, the

  6. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    DEFF Research Database (Denmark)

    Chang, Y.-Y.; Chen, P.; Huang, J.-J.

    2015-01-01

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88 × 2.88 mm2...... pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk...... and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection...

  7. Inverted opal luminescent Ce-doped silica glasses

    Directory of Open Access Journals (Sweden)

    R. Scotti

    2006-01-01

    Full Text Available Inverted opal Ce-doped silica glasses (Ce : Si molar ratio 1 ⋅ 10−3 were prepared by a sol-gel method using opals of latex microspheres as templates. The rare earth is homogeneously dispersed in silica host matrix, as evidenced by the absence of segregated CeO2, instead present in monolithic Ce-doped SG with the same cerium content. This suggests that the nanometric dimensions of bridges and junctions of the host matrix in the inverted opal structures favor the RE distribution avoiding the possible segregation of CeO2.

  8. An Improved Fuzzy Logic Controller Design for PV Inverters Utilizing Differential Search Optimization

    Directory of Open Access Journals (Sweden)

    Ammar Hussein Mutlag

    2014-01-01

    Full Text Available This paper presents an adaptive fuzzy logic controller (FLC design technique for photovoltaic (PV inverters using differential search algorithm (DSA. This technique avoids the exhaustive traditional trial and error procedure in obtaining membership functions (MFs used in conventional FLCs. This technique is implemented during the inverter design phase by generating adaptive MFs based on the evaluation results of the objective function formulated by the DSA. In this work, the mean square error (MSE of the inverter output voltage is used as an objective function. The DSA optimizes the MFs such that the inverter provides the lowest MSE for output voltage and improves the performance of the PV inverter output in terms of amplitude and frequency. The design procedure and accuracy of the optimum FLC are illustrated and investigated using simulations conducted for a 3 kW three-phase inverter in a MATLAB/Simulink environment. Results show that the proposed controller can successfully obtain the desired output when different linear and nonlinear loads are connected to the system. Furthermore, the inverter has reasonably low steady state error and fast response to reference variation.

  9. Motion Analysis Based on Invertible Rapid Transform

    Directory of Open Access Journals (Sweden)

    J. Turan

    1999-06-01

    Full Text Available This paper presents the results of a study on the use of invertible rapid transform (IRT for the motion estimation in a sequence of images. Motion estimation algorithms based on the analysis of the matrix of states (produced in the IRT calculation are described. The new method was used experimentally to estimate crowd and traffic motion from the image data sequences captured at railway stations and at high ways in large cities. The motion vectors may be used to devise a polar plot (showing velocity magnitude and direction for moving objects where the dominant motion tendency can be seen. The experimental results of comparison of the new motion estimation methods with other well known block matching methods (full search, 2D-log, method based on conventional (cross correlation (CC function or phase correlation (PC function for application of crowd motion estimation are also presented.

  10. Final Report Report: Smart Grid Ready PV Inverters with Utility Communication

    Energy Technology Data Exchange (ETDEWEB)

    Seal, Brian [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Huque, Aminul [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Rogers, Lindsey [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Key, Tom [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Riley, Cameron [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Li, Huijuan [Electric Power Research Inst. (EPRI), Knovville, TN (United States); York, Ben [Electric Power Research Inst. (EPRI), Knovville, TN (United States); Purcell, Chris [BPL Global, Inc., Canonsburg, PA (United States); Pacific, Oliver [Spirae, Inc., Fort Collins, CO (United States); Ropp, Michael [Northern Plains Power Technologies, Brookings, SD (United States); Tran, Teresa [DTE Energy, Detroit, MI (United States); Asgeirsson, Hawk [DTE Energy, Detroit, MI (United States); Woodard, Justin [National Grid, Warwick (United Kingdom); Steffel, Steve [Pepco Holdings, Inc., Washington, DC (United States)

    2016-03-30

    In 2011, EPRI began a four-year effort under the Department of Energy (DOE) SunShot Initiative Solar Energy Grid Integration Systems - Advanced Concepts (SEGIS-AC) to demonstrate smart grid ready inverters with utility communication. The objective of the project was to successfully implement and demonstrate effective utilization of inverters with grid support functionality to capture the full value of distributed photovoltaic (PV). The project leveraged ongoing investments and expanded PV inverter capabilities, to enable grid operators to better utilize these grid assets. Developing and implementing key elements of PV inverter grid support capabilities will increase the distribution system’s capacity for higher penetration levels of PV, while reducing the cost. The project team included EPRI, Yaskawa-Solectria Solar, Spirae, BPL Global, DTE Energy, National Grid, Pepco, EDD, NPPT and NREL. The project was divided into three phases: development, deployment, and demonstration. Within each phase, the key areas included: head-end communications for Distributed Energy Resources (DER) at the utility operations center; methods for coordinating DER with existing distribution equipment; back-end PV plant master controller; and inverters with smart-grid functionality. Four demonstration sites were chosen in three regions of the United States with different types of utility operating systems and implementations of utility-scale PV inverters. This report summarizes the project and findings from field demonstration at three utility sites.

  11. Multilayer control for inverters in parallel operation without signal interconnection

    DEFF Research Database (Denmark)

    Hua, Ming; Hu, Haibing; Xing, Yan

    2011-01-01

    A multilayer control is proposed for inverters with wireless parallel operation in this paper. The control is embedded in every inverter respectively and consists of three layers. The first layer is based on an improved droop method, which shares the active and reactive power in each module...

  12. Power losses in bilayer inverted small molecule organic solar cells

    KAUST Repository

    Trinh, Cong

    2012-01-01

    Inverted bilayer organic solar cells using copper phthalocyanine (CuPc) as a donor and C60 as an acceptor with the structure: glass/indium tin oxide (ITO)/ZnO/C60/CuPc/MoO3/Al, in which the zinc oxide (ZnO) was deposited by atomic layer deposition, are compared with a conventional device: glass/ITO/CuPc/C60/bathocuproine/Al. These inverted and conventional devices give short circuit currents of 3.7 and 4.8 mA/cm 2, respectively. However, the inverted device gives a reduced photoresponse from the CuPc donor compared to that of the conventional device. Optical field models show that the arrangement of organic layers in the inverted devices leads to lower absorption of long wavelengths by the CuPc donor; the low energy portion of the spectrum is concentrated near the metal oxide electrode in both devices. © 2012 American Institute of Physics.

  13. Three Level Diode Clamped Inverter Fed Induction Motor with Dtc-Svm

    OpenAIRE

    V. Ranjith Kumar

    2013-01-01

    This project presents a three-level diode-clamped inverter feeding an asynchronous motor drive with direct torque control (DTC). The control method is based on DTC operating principles. The stator voltage vector reference is computed from the stator flux and torque errors imposed by the flux and torque controllers. This voltage reference is then generated using a diode-clamped inverter, where each phase of the inverter can be implemented using a dc source, which would be available from fuel c...

  14. Monolithically Integrated Flexible Black Phosphorus Complementary Inverter Circuits.

    Science.gov (United States)

    Liu, Yuanda; Ang, Kah-Wee

    2017-07-25

    Two-dimensional (2D) inverters are a fundamental building block for flexible logic circuits which have previously been realized by heterogeneously wiring transistors with two discrete channel materials. Here, we demonstrate a monolithically integrated complementary inverter made using a homogeneous black phosphorus (BP) nanosheet on flexible substrates. The digital logic inverter circuit is demonstrated via effective threshold voltage tuning within a single BP material, which offers both electron and hole dominated conducting channels with nearly symmetric pinch-off and current saturation. Controllable electron concentration is achieved by accurately modulating the aluminum (Al) donor doping, which realizes BP n-FET with a room-temperature on/off ratio >10 3 . Simultaneously, work function engineering is employed to obtain a low Schottky barrier contact electrode that facilities hole injection, thus enhancing the current density of the BP p-FET by 9.4 times. The flexible inverter circuit shows a clear digital logic voltage inversion operation along with a larger-than-unity direct current voltage gain, while exhibits alternating current dynamic signal switching at a record high frequency up to 100 kHz and remarkable electrical stability upon mechanical bending with a radii as small as 4 mm. Our study demonstrates a practical monolithic integration strategy for achieving functional logic circuits on one material platform, paving the way for future high-density flexible electronic applications.

  15. Mathematical Model of Thyristor Inverter Including a Series-parallel Resonant Circuit

    OpenAIRE

    Miroslaw Luft; Elzbieta Szychta

    2008-01-01

    The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with theaid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  16. Techniques for the optimal design of photovoltaic inverters interconnected with the electric grid

    DEFF Research Database (Denmark)

    Koutroulis, Eftichios; Blaabjerg, Frede

    2011-01-01

    the Genetic Algorithm-based optimization procedure is the PV inverter Levelized Cost Of the Electricity generated (LCOE). The proposed method has been applied for the optimal design of PV inverters installed at various sites in Europe. The simulation results indicate that the optimal values of the PV inverter...

  17. PWM control of current source type six-phase inverter with improved waveforms by coupling reactor; Ketsugo reactor ni yori hakei kaizen sareta denryugata rokuso inverter no PWM seigyo

    Energy Technology Data Exchange (ETDEWEB)

    Inami, K.; Danjo, M.; Kondo, Y.; Yamada, M. [Niihama Technical College, Ehime (Japan); Toki, K. [Shikoku Electric Power Co., Inc., Kagawa (Japan); Heike, J. [Shikoku Instrumentation Co. Ltd., Kagawa (Japan)

    1998-10-01

    A PWM method has been applied to a high capacity six phase current source inverter system in order to obtain sinusoidal output voltage and current. In this system, the three-phase coupling reactor is connected between the inverter output and an induction motor used as a load. Then the reactor eliminates harmonic components included in the inverter output current except 12k {+-} 1 (k=1,2,3)th order. As a result, the distortion factor of the inverter output current decreases. But the resonant circuit is composed of the capacitance of filter capacitor and the induction motor leakage inductance. Then the resonance current is superimposed on the induction motor phase currents. To solve this problem, the optimal PWM pattern is derived, so that the resonant current becomes very small. The order of the resonant frequency component of the induction motor phase current depend on the inverter frequency. Then total inverter frequency range is divided into several areas. The optimal PWM pattern is derived in each areas. As a result, the use of each optimal PWM pattern allows us to drive the induction motor, over a wide range of speed, under the condition of small distortion factor of phase currents. 5 refs., 10 figs., 1 tab.

  18. Power system services provided by inverter connected distributed energy resources

    DEFF Research Database (Denmark)

    For the last few years there has been a significant increase of DER units in Denmark, of those units more and more are connected to the power system using inverters. These inverter connected units have the potential to support the electrical power system with various power system services. One...

  19. Discontinuous interleaving of parallel inverters for efficiency improvement

    DEFF Research Database (Denmark)

    Rannestad, Bjørn; Munk-Nielsen, Stig; Gadgaard, Kristian

    2017-01-01

    Interleaved switching of parallel inverters has previously been proposed for efficiency/size improvements of grid connected three-phase inverters. This paper proposes a novel interleaving method which practically eliminates insulated gate bipolar transistor (IGBT) turn-on losses and drastically...... overall power module losses are reduced. The modulation strategy is suited for converters with doubly fed induction generators (DFIG) for wind turbines, but are not limited hereto. Improvement of switching performance are measured and operational efficiency improvements are calculated and verified...

  20. Control of Single-Stage Single-Phase PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2005-01-01

    In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers have been implemented and an experimental comparison between them has been made. A complete control structure for the single-phase PV system is also presented......-forward; - and the grid current controller implemented in two different ways, using the classical proportional integral (PI) and the novel proportional resonant (PR) controllers. The control strategy was tested experimentally on 1.5 kW PV inverter....

  1. Mathematical model of thyristor inverter including a series-parallel resonant circuit

    OpenAIRE

    Luft, M.; Szychta, E.

    2008-01-01

    The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with the aid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  2. The Inverted Discoid Meniscus Segment: Clinical, Radiographic, and Arthroscopic Description of a Hidden Tear Pattern.

    Science.gov (United States)

    LaMont, Lauren; Ellis, Henry; Wise, Kelsey; Wilson, Philip

    2016-06-01

    A flipped, or inverted, meniscus segment is easily visualized in the normal meniscus. However, an inverted discoid meniscus segment may be difficult to appreciate because the tear occurs more centrally and leaves more meniscal rim; thus, it may be undertreated if not addressed during arthroscopy. To describe findings on clinical history, radiographs, MRI, and arthroscopy of a lateral discoid meniscus with an inverted segment and compare them with characteristics of a lateral discoid meniscus without an inverted segment. Case-control study; Level of evidence, 3. Between 2009 and 2012, a retrospective series of 121 consecutive knee arthroscopies for symptomatic lateral discoid meniscus were reviewed for the presence of an inverted fragment. Chart review of clinical presentation, operative reports, radiographic images, and arthroscopic images was performed. Comparative analysis of the clinical presentation between lateral discoid menisci with an inverted segment and noninverted lateral discoid menisci was performed by use of Fisher exact test and Mann-Whitney test. Nineteen patients with an inverted discoid meniscus segment (14 males, 5 females; average age, 15.0 years; range, 9.5-17.0 years) were compared with 102 patients with a noninverted discoid meniscus (53 males, 49 females; average age, 12.3 years; range, 5-17.0 years) (P = .011 for sex and P meniscus patients with an inverted segment had activity-related knee pain. Only 4 patients (21.0%) reported mechanical symptoms. Patients with an inverted discoid segment, compared with patients with discoid menisci without inverted segments, were more likely to have instability and effusion (P = .012 and P meniscus patients with an inverted segment (94.7%) had an injury, while only 41.2% of patients with noninverted symptomatic discoid menisci had an injury (P meniscus. During arthroscopy, the inverted discoid segment appeared normal, without a tear; upon probing, however, the inverted segment could be exposed. An

  3. Functional inverted Wishart for Bayesian multivariate spatial modeling with application to regional climatology model data.

    Science.gov (United States)

    Duan, L L; Szczesniak, R D; Wang, X

    2017-11-01

    Modern environmental and climatological studies produce multiple outcomes at high spatial resolutions. Multivariate spatial modeling is an established means to quantify cross-correlation among outcomes. However, existing models typically suffer from poor computational efficiency and lack the flexibility to simultaneously estimate auto- and cross-covariance structures. In this article, we undertake a novel construction of covariance by utilizing spectral convolution and by imposing an inverted Wishart prior on the cross-correlation structure. The cross-correlation structure with this functional inverted Wishart prior flexibly accommodates not only positive but also weak or negative associations among outcomes while preserving spatial resolution. Furthermore, the proposed model is computationally efficient and produces easily interpretable results, including the individual autocovariances and full cross-correlation matrices, as well as a partial cross-correlation matrix reflecting the outcome correlation after excluding the effects caused by spatial convolution. The model is examined using simulated data sets under different scenarios. It is also applied to the data from the North American Regional Climate Change Assessment Program, examining long-term associations between surface outcomes for air temperature, pressure, humidity, and radiation, on the land area of the North American West Coast. Results and predictive performance are compared with findings from approaches using convolution only or coregionalization.

  4. Functional inverted Wishart for Bayesian multivariate spatial modeling with application to regional climatology model data

    Science.gov (United States)

    Duan, L. L.; Szczesniak, R. D.; Wang, X.

    2018-01-01

    Modern environmental and climatological studies produce multiple outcomes at high spatial resolutions. Multivariate spatial modeling is an established means to quantify cross-correlation among outcomes. However, existing models typically suffer from poor computational efficiency and lack the flexibility to simultaneously estimate auto- and cross-covariance structures. In this article, we undertake a novel construction of covariance by utilizing spectral convolution and by imposing an inverted Wishart prior on the cross-correlation structure. The cross-correlation structure with this functional inverted Wishart prior flexibly accommodates not only positive but also weak or negative associations among outcomes while preserving spatial resolution. Furthermore, the proposed model is computationally efficient and produces easily interpretable results, including the individual autocovariances and full cross-correlation matrices, as well as a partial cross-correlation matrix reflecting the outcome correlation after excluding the effects caused by spatial convolution. The model is examined using simulated data sets under different scenarios. It is also applied to the data from the North American Regional Climate Change Assessment Program, examining long-term associations between surface outcomes for air temperature, pressure, humidity, and radiation, on the land area of the North American West Coast. Results and predictive performance are compared with findings from approaches using convolution only or coregionalization. PMID:29576735

  5. Classification and Construction of Invertible Linear Differential Operators on a One-Dimensional Manifold

    Directory of Open Access Journals (Sweden)

    V. N. Chetverikov

    2014-01-01

    Full Text Available Invertible linear differential operators with one independent variable are investigated. The problem of description of such operators is important, because it is connected with transformations and the classification of control systems, in particular, with the flatness problem.Each invertible linear differential operator represents a square matrix of scalar differential operators. Its product with an operator-column is an operator-column whose order does not exceed the sum of orders of initial operators. The operators-columns, the product with which leads to order fall, i.e. the order of the product is less than sum of orders of factors, are interesting for the description of invertible operators. In this paper the classification of invertible operators is based on dimensions dk,p of intersections of modules Gp and Fk for various k and p, where Gp is the module of all operators-columns of order not above p, and Fk is the module of compositions of the invertible operator with all operators-columns of order not above k. The invertible operators that have identical sets of numbers dk,p form one class.In the paper the general properties of tables of numbers dk,p for invertible operators are investigated. A correspondence between invertible operators and elementary-geometrical models which in the paper are named by d-schemes of squares is constructed. The invertible operator is ambiguously defined by its d-scheme of squares. The mathematical structure that must be set for its unique definition and an algorithm for the construction of the invertible operator are offered.In the proof of the main result, methods of the theory of chain complexes and their spectral sequences are used. In the paper all necessary concepts of this theory are formulated and the corresponding facts are proved.Results of the paper can be used for solving problems in which invertible linear differential operators are arisen. Namely, it is necessary to formulate the conditions on

  6. The inverted Batman incision: a new incision in transcolumellar incision for open rhinoplasty.

    Science.gov (United States)

    Nakanishi, Yuji; Nagasao, Tomohisa; Shimizu, Yusuke; Miyamoto, Junpei; Fukuta, Keizo; Kishi, Kazuo

    2013-12-01

    Columellar and nostril shapes often present irregularity after transcolumellar incision for open rhinoplasty, because of the contracture of the incised wound. The present study introduces a new technique to prevent this complication, and verifies its efficacy in improving cosmetic appearance. In our new method, a zig-zag incision with three small triangular flaps is made on the columella and in the pericolumellar regions of the bilateral nostril rims. Since the shape of the incision resembles the contour of an inverted "batman", we term our new method the "Inverted Batman" incision. To verify the effectiveness of the Inverted Batman incision, aesthetic evaluation was conducted for 21 patients operated on using the conventional transcolumellar incision (Conventional Group) and 19 patients operated on using the Inverted Batman incision (Inverted Batman Group). The evaluation was performed by three plastic surgeons, using a four-grade scale to assess three separate items: symmetry of bilateral soft triangles, symmetry of bilateral margins of the columella, and evenness of the columellar surface. The scores of the two groups for these three items were compared using a non-parametric test (Mann-Whitney U-test). With all three items, the Inverted Batman group patients present higher scores than Conventional Group patients. The Inverted Batman incision is effective in preserving the correct anatomical structure of the columella, soft triangle, and nostril rims. Hence, we recommend the Inverted Batman incision as a useful technique for open rhinoplasty.

  7. A grid-connected single-phase photovoltaic micro inverter

    Science.gov (United States)

    Wen, X. Y.; Lin, P. J.; Chen, Z. C.; Wu, L. J.; Cheng, S. Y.

    2017-11-01

    In this paper, the topology of a single-phase grid-connected photovoltaic (PV) micro-inverter is proposed. The PV micro-inverter consists of DC-DC stage with high voltage gain boost and DC-AC conversion stage. In the first stage, we apply the active clamp circuit and two voltage multipliers to achieve soft switching technology and high voltage gain. In addition, the flower pollination algorithm (FPA) is employed for the maximum power point tracking (MPPT) in the PV module in this stage. The second stage cascades a H-bridge inverter and LCL filter. To feed high quality sinusoidal power into the grid, the software phase lock, outer voltage loop and inner current loop control method are adopted as the control strategy. The performance of the proposed topology is tested by Matlab/Simulink. A PV module with maximum power 300W and maximum power point voltage 40V is applied as the input source. The simulation results indicate that the proposed topology and the control strategy are feasible.

  8. Linear polarization-discriminatory state inverter fabricated by oblique angle deposition.

    Science.gov (United States)

    Park, Yong Jun; Sobahan, K M A; Kim, Jin Joo; Hwangbo, Chang Kwon

    2009-06-22

    In this paper, we report a linear polarization-discriminatory state inverter made of three-layer sculpture thin film fabricated by oblique angle deposition technique. The first and third layers are quarter-wave plates of zigzag structure and the middle of them is a circular Bragg reflector of left-handed helical structure. It is found that the normal incidence of P-polarized light on this polarization-discriminatory state inverter becomes the S-polarized light at output, while the incident S-polarized light of wavelength lying in the Bragg regime is reflected. The microstructure of the linear polarization-discriminatory state inverter is also investigated by using a scanning electron microscope.

  9. Inverted hierarchy and asymptotic freedom in grand unified supersymmetric theories

    International Nuclear Information System (INIS)

    Aratyn, H.

    1983-01-01

    The interrelation between an inverted hierarchy mechanism and asymptotic freedom in supersymmetric theories is analyzed in two models for which we performed a detailed analysis of the effective potentials and effective couplings. We find it difficult to accommodate an inverted hierarchy together with asymptotic freedom for the matter-Yukawa couplings. (orig.)

  10. Mathematical Model of Thyristor Inverter Including a Series-parallel Resonant Circuit

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The article presents a mathematical model of thyristor inverter including a series-parallel resonant circuit with theaid of state variable method. Maple procedures are used to compute current and voltage waveforms in the inverter.

  11. Reliability Assessment of Transformerless PV Inverters Considering Mission Profiles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2015-01-01

    reliability of three transformerless inverters under a yearly mission profile (i.e., solar irradiance and ambient temperature). The mission profile is translated to device thermal loading, which is used for lifetime prediction. Compar¬ison results reveal the lifetime mismatches among the power switching......Due to the small volume and high efficiency, transformerless inverters have gained much popularity in grid-connected PV applications, where minimizing leakage current injection is mandatory. This can be achieved either by modifying the modulation schemes or adding extra power switching devices......, resulting in an uneven distribution of the power losses on the switching devices. Consequently, the device thermal loading is redis-tributed, and thus may alter the entire inverter reliability performance, especially under a long-term operation. In this consideration, this paper assesses the device...

  12. A Synchronization Method for Single-Phase Grid-Tied Inverters

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Yang, Yongheng

    2016-01-01

    The controllers of single-phase grid-tied inverters require improvements to enable distribution generation systems to meet the grid codes/standards with respect to power quality and the fault ride through capability. In that case, the response of the selected synchronization technique is crucial...... for the performance of the entire grid-tied inverter. In this paper, a new synchronization method with good dynamics and high accuracy under a highly distorted voltage is proposed. This method uses a Multi-Harmonic Decoupling Cell (MHDC), which thus can cancel out the oscillations on the synchronization signals due...... to the harmonic voltage distortion while maintaining the dynamic response of the synchronization. Therefore, the accurate and dynamic response of the proposed MHDC-PLL can be beneficial for the performance of the whole single-phase grid-tied inverter....

  13. Self-Oscillating Resonant Gate Drive for Resonant Inverters and Rectifiers Composed Solely of Passive Components

    DEFF Research Database (Denmark)

    Madsen, Mickey Pierre; Pedersen, Jeppe Arnsdorf; Knott, Arnold

    2014-01-01

    to improve the performance of the gate drive and how the gate drive can be implemented in a class E inverter, a class DE inverter and in class E inverter with a synchronous class E rectifier. The paper shows practical implementations of all the proposed inverters and converters operating in the Very High...

  14. Experimental Analysis of Variable Capacity Heat Pump Systems equipped with a liquid-cooled frequency inverter

    OpenAIRE

    Ebraheem, Thair

    2013-01-01

    Using an inverter-driven compressor in variable capacity heat pump systems has a main drawback, which is the extra loss in the inverter. The present experimental study aims to recover the inverter losses by using brine-cooled and water-cooled inverters, thereby improving the total efficiency of the heat pump system. In order to achieve this goal, a test rig with the air-cooled, water-cooled and brine-cooled inverters is designed and built, and a comparative analysis of the recovered heat, inv...

  15. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Dhople, Sairaj [University of Minnesota

    2017-09-28

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  16. Single stage three level grid interactive MPPT inverter for PV systems

    International Nuclear Information System (INIS)

    Ozdemir, Saban; Altin, Necmi; Sefa, Ibrahim

    2014-01-01

    Highlights: • A three phase three-level NPC inverter for grid interactive PV systems is proposed. • A novel MPPT algorithm is introduced for single stage systems. • The proposed algorithm is robust with respect to parameter variations of PV system. • THD level is measured as 3.45% and it meets the international standards (<5%). • Total system efficiency is measured as 93.08%. - Abstract: In this study, three-phase, single stage neutral point clamped grid interactive inverter is designed and implemented. The reference current of the voltage source inverter is determined by maximum power point tracking sub-program in order to obtain maximum power from photovoltaic modules instantaneously. Proposed control is realized via TMS320F28335 32-bit floating point processor. The modified incremental conductance method is applied for maximum power point tracking; the PI regulator is used to control the inverter output current shape and level. Galvanic isolation is provided by a line frequency transformer that matches inverter output voltage to the grid voltage level and prevents DC current injection into the grid. Experimental results show that the designed inverter imports energy to the grid with unity power factor, total harmonic distortion level is 3.45% and this value is in the limits of the international standards. In addition, the total efficiency of the system is measured as 93.08%. The proposed system gets the maximum power from photovoltaic module and dispatches into the grid without using additional DC/DC converter

  17. Extended topologies of tapped-inductor Z-source inverters

    DEFF Research Database (Denmark)

    Zhu, Miao; Li, Ding; Gao, Feng

    2011-01-01

    In this paper, two distinct types of tapped-inductor Z-source impedance networks are proposed for implementing high performance voltage-type inverters topologies with strong voltage boost inversion abilities and less components' stresses. All proposed topologies can in principle be unified...... into a generic network entity, which is termed hybrid-source tapped-inductor impedance network. The resulting novel Z-source inverters would have a higher output voltage gain and other unique advantages that currently have not yet been investigated. Theoretical analysis for explaining these operating features...

  18. Analysis and Modeling of Circulating Current in Two Parallel-Connected Inverters

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand

    2015-01-01

    Parallel-connected inverters are gaining attention for high power applications because of the limited power handling capability of the power modules. Moreover, the parallel-connected inverters may have low total harmonic distortion of the ac current if they are operated with the interleaved pulse...... this model, the circulating current between two parallel-connected inverters is analysed in this study. The peak and root mean square (rms) values of the normalised circulating current are calculated for different PWM methods, which makes this analysis a valuable tool to design a filter for the circulating......-width modulation (PWM). However, the interleaved PWM causes a circulating current between the inverters, which in turn causes additional losses. A model describing the dynamics of the circulating current is presented in this study which shows that the circulating current depends on the common-mode voltage. Using...

  19. Addressable Inverter Matrix Tests Integrated-Circuit Wafer

    Science.gov (United States)

    Buehler, Martin G.

    1988-01-01

    Addressing elements indirectly through shift register reduces number of test probes. With aid of new technique, complex test structure on silicon wafer tested with relatively small number of test probes. Conserves silicon area by reduction of area devoted to pads. Allows thorough evaluation of test structure characteristics and of manufacturing process parameters. Test structure consists of shift register and matrix of inverter/transmission-gate cells connected to two-by-ten array of probe pads. Entire pattern contained in square area having only 1.6-millimeter sides. Shift register is conventional static CMOS device using inverters and transmission gates in master/slave D flip-flop configuration.

  20. A PWM strategy for acoustic noise reduction for grid-connected single-phase inverters

    Energy Technology Data Exchange (ETDEWEB)

    Shao, R.; Guo, Z.; Chang, L. [New Brunswick Univ., Fredericton, NB (Canada). Dept. of Electrical and Computer Engineering

    2006-07-01

    This paper presented a newly proposed and improved pulse width modulation (PWM) strategy for grid-connected single-phase inverters. Small distributed generators using energy from renewable resources such as PV and wind systems typically use grid-connected single-phase inverters as voltage source inverters for good acoustic performance. PWM is generally applied in these inverters in order to achieve good waveforms of output current as required by interconnection standards. In routine simultaneous switching PWM methods, the current ripples through the inverter output filter inductor are at the carrier switching frequency, which is one of the major causes for inverter acoustic noise. The new PWM strategy effectively alleviates acoustic noise and improves output power quality. It is based on the principle of evenly splitting the switching of Insulated Gate Bipolar Transistors (IGBT) in each switching cycle among all IGBTs of the full bridge, thereby using a non-simultaneous mode of PWM which doubles the output current ripple frequency. This increases the inductor current ripple frequency to twice the carrier frequency. It is therefore possible to increase the current ripple frequency, or noise frequency into the range of ultrasonic which is inaudible to the human ear, without increasing the inverter's switching frequency to which the inverter's switching loss is proportional. In addition, this new PWM scheme can reduce the output current harmonics distortion and dc link current ripples. As such, lower capacitance in dc link capacitors and lower inductance of output inductor are needed. The improved PWM scheme was verified in a 3 kW grid-connected single-phase inverter. It was shown that the PWM strategy can be readily implemented with a digital signal processing microcontroller. 8 refs., 11 figs.

  1. A review of single-phase grid-connected inverters for photovoltaic modules

    DEFF Research Database (Denmark)

    Kjaer, Soren Baekhoej; Pedersen, John Kim; Blaabjerg, Frede

    2005-01-01

    -phase grid; 3) whether they utilizes a transformer (either line or high frequency) or not; and 4) the type of grid-connected power stage. Various inverter topologies are presented, compared, and evaluated against demands, lifetime, component ratings, and cost. Finally, some of the topologies are pointed out......This review focuses on inverter technologies for connecting photovoltaic (PV) modules to a single-phase grid. The inverters are categorized into four classifications: 1) the number of power processing stages in cascade; 2) the type of power decoupling between the PV module(s) and the single...

  2. Silicon-controlled-rectifier square-wave inverter with protection against commutation failure

    Science.gov (United States)

    Birchenough, A. G.

    1971-01-01

    The square-wave SCR inverter that was designed, built, and tested includes a circuit to turn off the inverter in case of commutation failure. The basic power stage is a complementary impulse-commutated parallel inverter consisting of only six components. The 400-watt breadboard was tested while operating at + or - 28 volts, and it had a peak efficiency of 95.5 percent at 60 hertz and 91.7 percent at 400 hertz. The voltage regulation for a fixed input was 3 percent at 60 hertz. An analysis of the operation and design information is included.

  3. Three-Level Z-Source Inverters Using a Single LC Impedance Network

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Lim, Sok Wei; Gao, Feng

    2007-01-01

    two LC impedance networks and two isolated dc sources, which can significantly increase the overall system cost and require a more complex modulator for balancing the network inductive voltage boosting. Offering a number of less costly alternatives, this letter presents the design and control of two...... three-level Z-source inverters, whose output voltage can be stepped down or up using only a single LC impedance network connected between the dc input source and either a neutral-point-clamped (NPC) or dc-link cascaded inverter circuitry. Through careful design of their modulation scheme, both inverters...

  4. Comparative Study of Modulation Techniques for Two-Level Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2016-06-01

    Full Text Available A detailed comparative study of modulation techniques for single and three phase dc-ac inverters is presented.  Sinusoidal Pulse Width Modulation, Triplen Sinusoidal Pulse Width Modulation, Space Vector Modulation, Selective Harmonic Elimination and Wavelet Modulation are assessed and compared in terms of maximum fundamental output, harmonic performance, switching losses and operational mode.  The presented modulation techniques are applied to single and three phase voltage source inverters and are simulated using SIMULINK.  The simulation results clarify the inverter performance achieved using the different modulations techniques.

  5. Control Strategy of Three-Phase Photovoltaic Inverter under Low-Voltage Ride-Through Condition

    Directory of Open Access Journals (Sweden)

    Xianbo Wang

    2015-01-01

    Full Text Available The new energy promoting community has recently witnessed a surge of developments in photovoltaic power generation technologies. To fulfill the grid code requirement of photovoltaic inverter under low-voltage ride-through (LVRT condition, by utilizing the asymmetry feature of grid voltage, this paper aims to control both restraining negative sequence current and reactive power fluctuation on grid side to maintain balanced output of inverter. Two mathematical inverter models of grid-connected inverter containing LCL grid-side filter under both symmetrical and asymmetric grid are proposed. PR controller method is put forward based on inverter model under asymmetric grid. To ensure the stable operation of the inverter, grid voltage feedforward method is introduced to restrain current shock at the moment of voltage drop. Stable grid-connected operation and LVRT ability at grid drop have been achieved via a combination of rapid positive and negative sequence component extraction of accurate grid voltage synchronizing signals. Simulation and experimental results have verified the superior effectiveness of our proposed control strategy.

  6. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y.-Y., E-mail: gixd@hep1.phys.ntu.edu.tw [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Chen, C.R. [National Space Organization (NSPO), 8F., No. 9, Prosperity 1 s Rd., Hsinchu Science Park, Hsinchu 30078, Taiwan, ROC (China); Chen, P.; Huang, J.-J. [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Huang, M.A. [Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Department of Energy Engineering, National United University, 1, Lienda, Miaoli 36003, Taiwan, ROC (China); Liu, T.-C. [Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Nam, J.W. [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Wang, M.-Z., E-mail: mzwang@hep1.phys.ntu.edu.tw [Department of Physics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Leung Center for Cosmology and Particle Astrophysics, National Taiwan University, 1 Roosevelt Rd., Taipei 10617, Taiwan, ROC (China); Bogomolov, V. [Skobeltsyn Institute of Nuclear Physics of Lomonosov Moscow State University, Leninskie Gory 119234 (Russian Federation); Physics Department of Lomonosov Moscow State University, Leninskie Gory 119234 (Russian Federation); Brandt, S.; Budtz-Jørgensen, C. [National Space Institute, Astrophysics, Technical University of Denmark, DK-2800 Kongens, Lyngby (Denmark); and others

    2015-01-21

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88×2.88 mm{sup 2} pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection by contracting the incident angle of the scintillation. We optimized the design in the simulation and fabricated a test sample. The test sample reduced 52% crosstalk with a loss of 6% signal yield. The idea of the Inverted-Conical light guide can be adapted by scintillation detectors multi-pixel, imaging-purpose scintillation detectors such as the ultra-fast GRB observatory UFFO-UBAT, whose performances are sensitive to responding time, image resolution, and geometrical modifications.

  7. Inverted-conical light guide for crosstalk reduction in tightly-packed scintillator matrix and MAPMT assembly

    International Nuclear Information System (INIS)

    Chang, Y.-Y.; Chen, C.R.; Chen, P.; Huang, J.-J.; Huang, M.A.; Liu, T.-C.; Nam, J.W.; Wang, M.-Z.; Bogomolov, V.; Brandt, S.; Budtz-Jørgensen, C.

    2015-01-01

    In this paper we present the Inverted-Conical light guide designed for optical crosstalk reduction in the scintillator-MAPMT assemblies. The research was motivated by the 30% crosstalk observed in UFFO X-ray telescope, UBAT, during the preliminary calibration with MAPMTs of 64 2.88×2.88 mm 2 pixels and identically gridded YSO crystal matrices. We began the study with the energy and crosstalk calibrations of the detector, then we constructed a GEANT4 simulation with the customized metallic film model as the MAPMT photocathode. The simulation reproduced more than 70% of the crosstalk and explained it as a consequence of the total reflection produced by the photocathode. The result indicated that the crosstalk mechanism could be a common case in most of the contact-assembled scintillation detectors. The concept of the Inverted-Conical light guide was to suppress the total reflection by contracting the incident angle of the scintillation. We optimized the design in the simulation and fabricated a test sample. The test sample reduced 52% crosstalk with a loss of 6% signal yield. The idea of the Inverted-Conical light guide can be adapted by scintillation detectors multi-pixel, imaging-purpose scintillation detectors such as the ultra-fast GRB observatory UFFO-UBAT, whose performances are sensitive to responding time, image resolution, and geometrical modifications

  8. Regulation of the Output Voltage of an Inverter in Case of Load Variation

    Science.gov (United States)

    Diouri, Omar; Errahimi, Fatima; Es-Sbai, Najia

    2018-05-01

    In a DC/AC photovoltaic application, the stability of the output voltage of the inverter plays a very important role in the electrical systems. Such a photovoltaic system is constituted by an inverter, which makes it possible to convert the continuous energy to the alternative energy used in systems which operate under a voltage of 230V. The output of this inverter can be connected to a single load or more, at which time a second load is added in parallel with the first load. In this case, it proves a voltage drop at the output of the inverter. This problem influences the proper functioning of the electrical loads. Therefore, our contribution is to give a solution to this by compensating this voltage drop using a boost converter at the input of the inverter. This boost converter will play the role of the compensator that will provide the necessary voltage to the inverter in order to increase the voltage across the loads. But the use of this boost without controlling it is not enough because it generates a voltage that depends on the duty cycle of the control signal. To stabilize the output voltage of the inverter, we used a Proportional, Integral, and Derivative control (PID), which makes it possible to generate the necessary control signal for the voltage boost in order to have a good regulation of the output voltage of the inverter. Finally, we have solved the problem of the voltage drop even though there is loads variation.

  9. Progressive decrement PWM algorithm for minimum mean square error inverter output voltage

    International Nuclear Information System (INIS)

    Ghaeb, J.A.; Smadi, M.A.; Ababneh, M.

    2011-01-01

    Highlights: → The main contribution of this work is to provide a better performance for the power inverter operation. → The proposed technique splits the determined original pulse-width of an inverter operation in to many pulses. → The new approach extends the central pulse and shrinks the exterior pulses. → This is leading to an inverter output cycle close to the sinusoidal form of fewer harmonics. - Abstract: The paper proposes two modulation techniques for the power inverter. These new techniques are named progressive decrement PWM algorithm (PDPA) and progressive increment PWM algorithm (PIPA). Both techniques take the determined original pulse-width of an inverter operation and split it to many pulses. In the PDPA technique, the largest width is given to the middle pulse and the width of the boundary pulses is reduced progressively starting from the first boundary-pulse toward the last boundary-pulse. In the PIPA technique, there is a gradual increment instead of decrement. The two techniques have been proved that it can maintain the original pulse-width of the inverter operation. The new approach PDPA extends the central pulse and shrinks the exterior pulses, leading to an inverter output cycle close to the sinusoidal form of fewer harmonic contents. Simulation results are performed to evaluate the performances of the proposed techniques: PDPA and PIPA and to compare them with the well known methods. The main contribution of the proposed PDPA technique is that it provides a better performance for the most harmonic orders compared to the well established sinusoidal PWM technique.

  10. Inrush Transient Current Analysis and Suppression of Photovoltaic Grid-Connected Inverters During Voltage Sag

    DEFF Research Database (Denmark)

    Li, Zhongyu; Zhao, Rende; Xin, Zhen

    2016-01-01

    The Inrush Transient Current (ITC) in the output of the photovoltaic grid-connected inverters is usually generated when grid voltage sag occurs, which can trigger the protection of the grid-connected inverters, and even destroy the semiconductor switches. Then, the grid-connected inverters...

  11. Efficient cascade multiple heterojunction organic solar cells with inverted structure

    Science.gov (United States)

    Guo, Tingting; Li, Mingtao; Qiao, Zhenfang; Yu, Leiming; Zhao, Jianhong; Feng, Nianjun; Shi, Peiguang; Wang, Xiaoyan; Pu, Xiaoyun; Wang, Hai

    2018-05-01

    In this work, we demonstrate an efficient cascade multiple heterojunction organic solar cell with inverted structure. By using two donor materials, poly(3-hexylthiosphene) (P3HT) and titanyl phthalocyanine (TiOPc), as well as two acceptor materials, [6,6]-phenyl C61 butyric acid methyl ester (PCBM) and C60, the cascade multiple heterojunctions of P3HT:PCBM/TiOPc:C60/C60 have been constructed. Applying the optimized inverted configuration of FTO/Zinc Tin Oxide (ZTO)/C60 (30 nm)/TiOPc:C60 (1:1.5, 25 nm)/P3HT:PCBM (1:0.8, 100 nm)/MoO3 (4 nm)/Ag, the considerably enhanced open circuit voltage (VOC) and short circuit current (JSC) can be harvested together, and the power conversion efficiency (PCE) is three times higher than that of the control cell with conventional structure. The significant improvements of the inverted cell are mostly due to the broadened spectral absorption and high efficient multi-interface exciton dissociation in the cascade multiple heterojunctions, indicating that the optimized cascade heterojunctions match the inverted structure well.

  12. H-Bridge Transformerless Inverter with Common Ground for Single-Phase Solar-Photovoltaic System

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2017-01-01

    This paper proposes a new single-phase H-Bridge transformerless inverter with common ground for grid-connected photovoltaic systems (hereafter it is called ‘Siwakoti-H’ inverter). The inverter works on the principle of flying capacitor and consists of only four power switches (two reverse blocking...... IGBT's (RB-IGBT) and two MOSFET's), a capacitor and a small filter at the output stage. The proposed topology share a common ground with the grid and the PV source. A Unipolar Sinusoidal Pulse-Width Modulation (SPWM) technique is used to modulate the inverter to minimize switching loss, output current...

  13. Inverted base pavements: construction and performance

    KAUST Repository

    Papadopoulos, Efthymios; Santamarina, Carlos

    2017-01-01

    quality control. This study reviews the extensive South African experience and case histories in the USA. Accumulating evidence suggests that inverted base pavements are a viable alternative and can outperform conventional pavements at a lower cost

  14. Electronic inverter assembly with an integral snubber capacitor

    Science.gov (United States)

    Singh, Brij N.; Schmit, Christopher J.

    2017-08-01

    A coaxial bus connector has a first end and a second end opposite the first end. The first end has a first positive terminal and a first negative terminal coupled to a primary direct current bus of a primary inverter. The second end has a second positive terminal and a second negative terminal coupled to the secondary direct current bus of a secondary inverter, wherein the coaxial bus connector comprises a dielectric material between a center conductor and a coaxial sleeve to form a snubber capacitor to absorb electrical energy or to absorb voltage spikes.

  15. On the Impacts of PV Array Sizing on the Inverter Reliability and Lifetime

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2018-01-01

    , the total energy yield can be increased under weak solar irradiance conditions. However, oversizing the PV array will increase the loading of PV inverters, which may have undesired influence on the PV inverter reliability and lifetime. In that case, it may result in a negative impact on the overall PV...... energy cost, due to the increased maintenance for the PV inverters. With the above concern, this paper evaluates the reliability and lifetime of PV inverters considering the PV array sizing. The evaluation is based on the mission profile of the installation sites in Denmark and Arizona, where...... the reliability-critical components such as power devices and capacitors are considered. The results reveal that the variation in the PV array sizing can considerably deviate the reliability performance and lifetime expectation of PV inverters, especially for those installed in Denmark, where the average solar...

  16. Common voltage eliminating of SVM diode clamping three-level inverter connected to grid

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Zhu, Jieqiong

    2011-01-01

    A novel method of common voltage eliminating is put forward for SVM diode clamping three-level inverter connected to grid by calculation of common voltage of its various switching states. PLECS is used to model this three-level inverter connected to grid and good results are obtained. First...... analysis of common mode voltage for switching states of diode clamping 3-level inverter is given in detail. Second the common mode voltage eliminating control strategy of SVM is described for diode clamping three-level inverter. Third, PLECS is briefly introduced. Fourth, the modeling of diode clamping...... three-level inverter is presented with PLECS. Finally, a series of simulations are carried out. The simulation results tell us PLECS is a very powerful tool to real power circuits modeling. They have also verified that proposed common mode voltage eliminating control strategy of SVM is feasible...

  17. Two-Stage Series-Resonant Inverter

    Science.gov (United States)

    Stuart, Thomas A.

    1994-01-01

    Two-stage inverter includes variable-frequency, voltage-regulating first stage and fixed-frequency second stage. Lightweight circuit provides regulated power and is invulnerable to output short circuits. Does not require large capacitor across ac bus, like parallel resonant designs. Particularly suitable for use in ac-power-distribution system of aircraft.

  18. Inverting an Introductory Statistics Classroom

    Science.gov (United States)

    Kraut, Gertrud L.

    2015-01-01

    The inverted classroom allows more in-class time for inquiry-based learning and for working through more advanced problem-solving activities than does the traditional lecture class. The skills acquired in this learning environment offer benefits far beyond the statistics classroom. This paper discusses four ways that can make the inverted…

  19. Isolated high-efficiency grid-connected de-central inverter for photovoltaic modules

    NARCIS (Netherlands)

    Vermulst, B.J.D.

    2012-01-01

    While an increasing number of photovoltaic (PV) systems is installed, those systems typically use central inverters. In practical cases, output-power differences between PV modules will cause these central-inverter-based systems not to achieve Maximum Power Point (MPP) for each PV module.

  20. Harmonic currents Compensator Grid-Connected Inverter at the Microgrid

    DEFF Research Database (Denmark)

    Asuhaimi Mohd Zin, A.; Naderipour, A.; Habibuddin, M.H.

    2016-01-01

    The main challenge associated with the grid-connected inverter in distributed generation (DG) systems is to maintain the harmonic contents in output current below the specified values and compensates for unbalanced loads even when the grid is subject to disturbances such as harmonic distortion...... and unbalanced loads. To overcome these challenges, a current control strategy for a three-phase grid-connected inverter under unbalanced and nonlinear load conditions is presented. It enables grid-connected inverter by the proposed control method to inject balanced clean currents to the grid even when the local...... loads are unbalanced and/or nonlinear and also compensate of the harmonic currents and control the active and reactive power. The main advantage and objective of this method is to effectively compensate for the harmonic currents content of the grid current and microgrid without using any compensation...

  1. Improvements in EMC performance of inverter-fed motor drives

    International Nuclear Information System (INIS)

    Zhong, E.; Lipo, T.A.

    1995-01-01

    An experimental investigation of conducted radio-noise emission from a conventional pulse width modulated (PWM) inverter of medium power feeding an induction motor is described. It is determined that the inverter system generates considerable impulse currents through the power leads feeding the system resulting in serious conducted electromagnetic interference (EMI) problems and significant voltage waveform distortion in the power system. The dominant emission sources in the system are identified. A proposed model of the drive system for the purpose of evaluation of EMI are developed. Several low-cost strategies for improvement in EMC performance of the PWM inverter are then proposed. Experimental results demonstrate that disturbance from the modified system can be dramatically reduced and that the EMC performance of the system has come very close to meeting the IEC CISPR and FCC limits on conducted emissions for digital devices

  2. Multilevel inverter with optimal THD through the firefly algorithm

    Directory of Open Access Journals (Sweden)

    El Mehdi Belkacem Riadh

    2017-03-01

    Full Text Available Reduction of the Total Harmonic Distortion (THD in multilevel inverters requires resolution of complex nonlinear transcendental equations; in this paper we propose a combination of one of the best existing optimized hardware structures with the recent firefly algorithm, which was used to optimize the THD, through finding the best switching angles and guaranteeing the minimization of harmonics within a user defined bandwidth. The obtained THD through the simulation of the thirteen-level symmetric inverter has been reduced down to 5% (FFT of 60 harmonics. In order to validate the simulation results, a thirteen-level symmetric inverter prototype has been made, and practically experimented and tested with different loads. Consequently, the measured THD with resistive load was 4.7% on a bandwidth of 3 kHz. The main advantage of the achieved work is the reduction of the THD.

  3. Experimental study on flow pattern and heat transfer of inverted annular flow

    International Nuclear Information System (INIS)

    Takenaka, Nobuyuki; Akagawa, Koji; Fujii, Terushige; Nishida, Koji

    1990-01-01

    Experimental results are presented on flow pattern and heat transfer in the regions from inverted annular flow to dispersed flow in a vertical tube using freon R-113 as a working fluid at atmospheric pressure to discuss the correspondence between them. Axial distributions of heat transfer coefficient are measured and flow patterns are observed. The heat transfer characteristics are divided into three regions and a heat transfer characteristics map is proposed. The flow pattern changes from inverted annular flow (IAF) to dispersed flow (DF) through inverted slug flow (ISF) for lower inlet velocities and through agitated inverted annular flow (AIAF) for higher inlet velocities. A flow pattern map is obtained which corresponds well with the heat transfer characteristic map. (orig.)

  4. Amphiphilic invertible polymers: Self-assembly into functional materials driven by environment polarity

    Science.gov (United States)

    Hevus, Ivan

    Stimuli-responsive polymers adapt to environmental changes by adjusting their chain conformation in a fast and reversible way. Responsive polymeric materials have already found use in electronics, coatings industry, personal care, and bio-related areas. The current work aims at the development of novel responsive functional polymeric materials by manipulating environment-dependent self-assembly of a new class of responsive macromolecules strategically designed in this study,—amphiphilic invertible polymers (AIPs). Environment-dependent micellization and self-assembly of three different synthesized AIP types based on poly(ethylene glycol) as a hydrophilic fragment and varying hydrophobic constituents was demonstrated in polar and nonpolar solvents, as well as on the surfaces and interfaces. With increasing concentration, AIP micelles self-assemble into invertible micellar assemblies composed of hydrophilic and hydrophobic domains. Polarity-responsive properties of AIPs make invertible micellar assemblies functional in polar and nonpolar media including at interfaces. Thus, invertible micellar assemblies solubilize poorly soluble substances in their interior in polar and nonpolar solvents. In a polar aqueous medium, a novel stimuli-responsive mechanism of drug release based on response of AIP-based drug delivery system to polarity change upon contact with the target cell has been established using invertible micellar assemblies loaded with curcumin, a phytochemical drug. In a nonpolar medium, invertible micellar assemblies were applied simultaneously as nanoreactors and stabilizers for size-controlled synthesis of silver nanoparticles stable in both polar and nonpolar media. The developed amphiphilic nanosilver was subsequently used as seeds to promote anisotropic growth of CdSe semiconductor nanoparticles that have potential in different applications ranging from physics to medicine. Amphiphilic invertible polymers were shown to adsorb on the surface of silica

  5. Inverting Coseismic TEC Disturbances for Neutral Atmosphere Pressure Wave

    Science.gov (United States)

    Lee, R. F.; Mikesell, D.; Rolland, L.

    2017-12-01

    Research from the past 20 years has shown that we can detect coseismic disturbances in the total electron content (TEC) using global navigation space systems (GNSS). In the near field, TEC disturbances are created by the direct wave from rupture on the surface. This pressure wave travels through the neutral atmosphere to the ionosphere within about 10 minutes. This provides the opportunity to almost immediately characterize the source of the acoustic disturbance on the surface using methods from seismology. In populated areas, this could provide valuable information to first responders. To retrieve the surface motion amplitude information we must account for changes in the waveform caused by the geomagnetic field, motion of the satellites and the geometry of the satellites and receivers. One method is to use a transfer function to invert for the neutral atmosphere pressure wave. Gómez et al (2015) first employed an analytical model to invert for acoustic waves produced by Rayleigh waves propagating along the Earth's surface. Here, we examine the same model in the near field using the TEC disturbances from the direct wave produced by rupture at the surface. We compare results from the forward model against a numerical model that has been shown to be in good agreement with observations from the 2011 Van (Turkey) earthquake. We show the forward model predictions using both methods for the Van earthquake. We then analyze results for hypothetical events at different latitudes and discuss the reliability of the analytical model in each scenario. Gómez, D., R. Jr. Smalley, C. A. Langston, T. J. Wilson, M. Bevis, I. W. D. Dalziel, E. C. Kendrick, S. A. Konfal, M. J. Willis, D. A. Piñón, et al. (2015), Virtual array beamforming of GPS TEC observations of coseismic ionospheric disturbances near the Geomagnetic South Pole triggered by teleseismic megathrusts, J. Geophys. Res. Space Physics, 120, 9087-9101, doi:10.1002/2015JA021725.

  6. Analysis of balance control methods based on inverted pendulum for legged robots

    OpenAIRE

    Denisov, A.; Iakovlev, R.; Mamaev, I.; Pavliuk, N.

    2017-01-01

    Methods of balance control for a legged robot, the model of which is presented as a two-section inverted pendulum, are considered. The following balance methods for humanoid robots are analysed: the parallel algorithm of the network operator method; the method of natural synergies; the method of fuzzy control, the spherical inverted pendulum mode, a dual length linear inverted pendulum method. The best of these methods will be used in the development of the Russian anthropomorphic robot Antares.

  7. Incorporating an Electrode Modification Layer with a Vertical Phase Separated Photoactive Layer for Efficient and Stable Inverted Nonfullerene Polymer Solar Cells.

    Science.gov (United States)

    Shi, Zhenzhen; Liu, Hao; Wang, Yaping; Li, Jinyan; Bai, Yiming; Wang, Fuzhi; Bian, Xingming; Hayat, Tasawar; Alsaedi, Ahmed; Tan, Zhan'ao

    2017-12-20

    For bulk heterojunction polymer solar cells (PSCs), the donors and acceptors featuring specific phase separation and concentration distribution within the electron donor/acceptor blends crucially affect the exciton dissociation and charge transportation. Herein, efficient and stable nonfullerene inverted PSCs incorporating a phase separated photoactive layer and a titanium chelate electrode modification layer are demonstrated. Water contact angle (WCA), scanning kelvin probe microscopy (SKPM), and atomic force microscopy (AFM) techniques are implemented to characterize the morphology of photoactive layers. Compared with the control conventional device, the short-circuit current density (J sc ) is enhanced from 14.74 to 17.45 mAcm -2 . The power conversion efficiency (PCE) for the inverted PSCs with a titanium (diisopropoxide)-bis-(2,4-pentanedionate) (TIPD) layer increases from 9.67% to 11.69% benefiting from the declined exciton recombination and fairly enhanced charge transportation. Furthermore, the nonencapsulated inverted device with a TIPD layer demonstrates the best long-term stability, 85% of initial PCE remaining and an almost undecayed open-circuit voltage (V oc ) after 1440 h. Our results reveal that the titanium chelate is an excellent electrode modification layer to incorporate with a vertical phase separated photoactive layer for producing high-efficiency and high-stability inverted nonfullerene PSCs.

  8. Stability analysis of grid inverter LCL-filter resonance in wind or photovoltaic parks

    DEFF Research Database (Denmark)

    Arcuri, S.; Liserre, M.; Ricchiuto, D.

    2011-01-01

    Typically the resonance problems related to the use of LCL-filters in grid connected inverters are analyzed assuming the operation of a single inverter. Wind and photovoltaic parks may experience propagation of resonance from a poorly damped inverter to other systems connected in parallel....... The paper focuses on the study of the resonance at a park system level with simulations and experimental results....

  9. DC-DC Type High-Frequency Link DC for Improved Power Quality of Cascaded Multilevel Inverter

    Science.gov (United States)

    Sadikin, Muhammad; Senjyu, Tomonobu; Yona, Atsushi

    2013-06-01

    Multilevel inverters are emerging as a new breed of power converter options for power system applications. Recent advances in power switching devices enabled the suitability of multilevel inverters for high voltage and high power applications because they are connecting several devices in series without the need of component matching. Usually, a transformerless battery energy storage system, based on a cascaded multilevel inverter, is used as a measure for voltage and frequency deviations. System can be reduced in size, weight, and cost of energy storage system. High-frequency link circuit topology is advantageous in realizing compact and light-weight power converters for uninterruptible power supply systems, new energy systems using photovoltaic-cells, fuel-cells and so on. This paper presents a DC-DC type high-frequency link DC (HFLDC) cascaded multilevel inverter. Each converter cell is implemented a control strategy for two H-bridge inverters that are controlled with the same multicarrier pulse width modulation (PWM) technique. The proposed cascaded multilevel inverter generates lower voltage total harmonic distortion (THD) in comparison with conventional cascaded multilevel inverter. Digital simulations are carried out using PSCAD/EMTDC to validate the performance of the proposed cascaded multilevel inverter.

  10. Control of Grid Connected Photovoltaic System Using Three-Level T-Type Inverter

    Science.gov (United States)

    Zorig, Abdelmalik; Belkeiri, Mohammed; Barkat, Said; Rabhi, Abdelhamid

    2016-08-01

    Three-level T-Type inverter (3LT2I) topology has numerous advantageous compared to three-level neutral-point-clamped (NPC) inverter. The main benefits of 3LT2I inverter are the efficiency, inverter cost, switching losses, and the quality of output voltage waveforms. In this paper, a photovoltaic distributed generation system based on dual-stage topology of DC-DC boost converter and 3LT2I is introduced. To that end, a decoupling control strategy of 3LT2I is proposed to control the current injected into the grid, reactive power compensation, and DC-link voltage. The resulting system is able to extract the maximum power from photovoltaic generator, to achieve sinusoidal grid currents, and to ensure reactive power compensation. The voltage-balancing control of two split DC capacitors of the 3LT2I is achieved using three-level space vector modulation with balancing strategy based on the effective use of the redundant switching states of the inverter voltage vectors. The proposed system performance is investigated at different operating conditions.

  11. High-speed all-optical logic inverter based on stimulated Raman scattering in silicon nanocrystal.

    Science.gov (United States)

    Sen, Mrinal; Das, Mukul K

    2015-11-01

    In this paper, we propose a new device architecture for an all-optical logic inverter (NOT gate), which is cascadable with a similar device. The inverter is based on stimulated Raman scattering in silicon nanocrystal waveguides, which are embedded in a silicon photonic crystal structure. The Raman response function of silicon nanocrystal is evaluated to explore the transfer characteristic of the inverter. A maximum product criterion for the noise margin is taken to analyze the cascadability of the inverter. The time domain response of the inverter, which explores successful inversion operation at 100 Gb/s, is analyzed. Propagation delay of the inverter is on the order of 5 ps, which is less than the delay in most of the electronic logic families as of today. Overall dimension of the device is around 755  μm ×15  μm, which ensures integration compatibility with the matured silicon industry.

  12. Bibliographic review on sinonasal inverted papilloma

    International Nuclear Information System (INIS)

    Benavides Vilchez, Juan Vicente

    2014-01-01

    Surgical management recommendations, the index of recurrence and malignancy of the sinonasal inverted papilloma were identified through a bibliographic review of publications from 2002 to 2012. In the literature reviewed several aspects were determined: the risk of recurrences and the possibility of malignization of the inverted papilloma is diminished by complete surgical resection. The actual extent of the injury must be determined in an appropriate manner. The open approaches are recommended for a better visualization of the tumor, allowing the complete resection of the lesion. Endoscopic resection is considered a posterior surgical option, to evaluate the extension of the lesion without requiring incisions in the skin, it is recommended for the treatment of lesions in early stages and as a therapeutic option for some lesions in advanced stages. The recurrence rate is lower through endoscopy in relation to traditional approaches. The unilateral nasal obstruction and the presence of a mass in the nasal cavity are clinical manifestations of the inverted papilloma, whose highest incidence occurs in men and women, between 50 and 70 years of age. By means of clinical, radiological and biopsy suspicion this pathology is confirmed. The recurrence rate is 22% in a period of time from eight to 48 months after the initial surgery. The rate of malignization is 10%, which usually occurs between six and 60 months from the diagnosis of papilloma until the appearance of carcinoma [es

  13. A case report of an inverted papilloma infiltrating into maxillary sinus

    International Nuclear Information System (INIS)

    Ji, Yong Hwa; Choi, Bo Ram; Huh, Kyung Hoe; Lee, Sam Sun; An, Chang Hyeon

    2009-01-01

    The present study reports a case of inverted papilloma of the nasal cavity and infiltrating into the maxillary sinus. Inverted papilloma is an uncommon and locally aggressive benign tumor of the sinonasal region. The patient, 51-year-old male, presented with unilateral nasal obstruction and periodic swelling on the palate without pain. Enhanced CT scan revealed a heterogeneously enhancing solid mass in the nasal cavity and infiltrating into the right maxillary sinus, as well as an incidental, secondarily infected residual cyst in the periapical area of the right maxillary canine. The sinonasal mass was revealed as an inverted papilloma on histopathologic examination.

  14. A case report of an inverted papilloma infiltrating into maxillary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yong Hwa; Choi, Bo Ram; Huh, Kyung Hoe; Lee, Sam Sun [School of Dentistry, Seoul National University, Seoul (Korea, Republic of); An, Chang Hyeon [Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    2009-06-15

    The present study reports a case of inverted papilloma of the nasal cavity and infiltrating into the maxillary sinus. Inverted papilloma is an uncommon and locally aggressive benign tumor of the sinonasal region. The patient, 51-year-old male, presented with unilateral nasal obstruction and periodic swelling on the palate without pain. Enhanced CT scan revealed a heterogeneously enhancing solid mass in the nasal cavity and infiltrating into the right maxillary sinus, as well as an incidental, secondarily infected residual cyst in the periapical area of the right maxillary canine. The sinonasal mass was revealed as an inverted papilloma on histopathologic examination.

  15. Radiation effect on sucrose content of inverted sugar

    International Nuclear Information System (INIS)

    Podadera, Priscilla; Sabato, Susy F.

    2007-01-01

    Inverted sugar is a mixture of sucrose, glucose and fructose used as an ingredient in the food and beverage industry. During production there are points of contamination by microorganisms that can modify the sugar properties and reduce shelf life. This work aims to consider one efficient technique in the sanitization of this ingredient with minimum alterations in the sugar ratios. Irradiation with Cobalt 60 is a technique with proven efficacy in the reduction of microorganisms. Samples of inverted sugar had been radiated with Cobalt 60, Gammacell type, at the CTR-IPEN, with doses of 5, 10, 20, 30 and 50 kGy, and dose rate of 3.88 kGy/h. The content of sucrose was determined by the Fehling method. The sample irradiated at highest dose presented the most intense reduction in the concentration of sucrose: 13% in comparison to the control. Irradiated samples up to 30 kGy did not presented statistical difference in relation to the control (p<0.05), indicating that radiation can be applied to the inverted sugar without significant alterations in the concentration of sucrose. (author)

  16. Radiation effect on sucrose content of inverted sugar

    Energy Technology Data Exchange (ETDEWEB)

    Podadera, Priscilla; Sabato, Susy F. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes]. E-mails: ppodadera@yahoo.com.br; sfsabato@ipen.br

    2007-07-01

    Inverted sugar is a mixture of sucrose, glucose and fructose used as an ingredient in the food and beverage industry. During production there are points of contamination by microorganisms that can modify the sugar properties and reduce shelf life. This work aims to consider one efficient technique in the sanitization of this ingredient with minimum alterations in the sugar ratios. Irradiation with Cobalt 60 is a technique with proven efficacy in the reduction of microorganisms. Samples of inverted sugar had been radiated with Cobalt 60, Gammacell type, at the CTR-IPEN, with doses of 5, 10, 20, 30 and 50 kGy, and dose rate of 3.88 kGy/h. The content of sucrose was determined by the Fehling method. The sample irradiated at highest dose presented the most intense reduction in the concentration of sucrose: 13% in comparison to the control. Irradiated samples up to 30 kGy did not presented statistical difference in relation to the control (p<0.05), indicating that radiation can be applied to the inverted sugar without significant alterations in the concentration of sucrose. (author)

  17. Inverting the diastereoselectivity of the mukaiyama-michael addition with graphite-based catalysts

    KAUST Repository

    Acocella, Maria Rosaria; Mauro, Marco; Falivene, Laura; Cavallo, Luigi; Guerra, Gaetano

    2014-01-01

    , the graphite-based catalysts described here invert the diastereoselectivity relative to that observed with known catalysts, with the unprecedented large prevalence of the anti diastereoisomer. This inverted diastereoselectivity is increased when the catalyst

  18. Multiple output power supply circuit for an ion engine with shared upper inverter

    Science.gov (United States)

    Cardwell, Jr., Gilbert I. (Inventor); Phelps, Thomas K. (Inventor)

    2001-01-01

    A power supply circuit for an ion engine suitable for a spacecraft is coupled to a bus having a bus input and a bus return. The power supply circuit has a first primary winding of a first transformer. An upper inverter circuit is coupled to the bus input and the first primary winding. The power supply circuit further includes a first lower inverter circuit coupled to the bus return and the first primary winding. The second primary winding of a second transformer is coupled to the upper inverter circuit. A second lower inverter circuit is coupled to the bus return and the second primary winding.

  19. Analysis of balance control methods based on inverted pendulum for legged robots

    Directory of Open Access Journals (Sweden)

    Denisov Alexander

    2017-01-01

    Full Text Available Methods of balance control for a legged robot, the model of which is presented as a two-section inverted pendulum, are considered. The following balance methods for humanoid robots are analysed: the parallel algorithm of the network operator method; the method of natural synergies; the method of fuzzy control, the spherical inverted pendulum mode, a dual length linear inverted pendulum method. The best of these methods will be used in the development of the Russian anthropomorphic robot Antares.

  20. A case report of inverted papilloma of the posterior urethra

    OpenAIRE

    長谷川, 総一郎; 絹川, 常郎; 松浦, 治; 竹内, 宜久; 服部, 良平; 小野, 佳成; 大島, 伸一; 村上, 榮

    1987-01-01

    Sixty-seven cases of inverted papilloma have been reported in many anatomical sites of urinary tract but only 9 cases involving the posterior urethra have been described in Japan. We report the 10th case of inverted papilloma of the posterior urethra in a 27-year-old male who complained of macroscopic hematuria. The lesion was diagnosed cystoscopically and treated by transurethral resection.

  1. A low voltage programmable unipolar inverter with a gold nanoparticle monolayer on plastic.

    Science.gov (United States)

    Zhou, Ye; Han, Su-Ting; Huang, Long-Biao; Huang, Jing; Yan, Yan; Zhou, Li; Roy, V A L

    2013-05-24

    A programmable low voltage unipolar inverter with saturated-load configuration has been demonstrated on a plastic substrate. A self-assembled monolayer of gold (Au) nanoparticles was inserted into the dielectric layer acting as a charge trapping layer. The inverter operated well with supply voltages of inverter. Furthermore, the programmable behavior was maintained well at various bending states, demonstrating the adequate flexibility of our devices.

  2. Rancang Bangun Inverter SVM Berbasis Mikrokontroler PIC 18F4431 Untuk Sistem VSD

    OpenAIRE

    Tarmizi; Muyassar

    2013-01-01

    Sebuah sistem pengaturan kecepatan motor disebut dengan sistem Variable Speed Drives (VSD). Sistem VSD motor induksi menggunakan inverter untuk mengatur frekuensi suplai motor. Untuk mendapatkan frekuensi suplai motor yang mendekati sinusoidal, inveter perlu di switching dengan metode tertentu. Pada penelitian ini, switching inverter 3 fasa menggunakan metode SVM (Space Vector Modulation) yang dikontrol oleh Mikrokontroler PIC18F4431. Sebelum dilakukan ekperimen, inverter SVM ini lakukan si...

  3. Characteristics of GaAs MESFET inverters exposed to high energy neutrons

    International Nuclear Information System (INIS)

    Bloss, W.L.; Yamada, W.E.; Young, A.M.; Janousek, B.K.

    1988-01-01

    GaAs MESFET circuits have been exposed to high energy neutrons with fluences ranging from 1x10/sup 14/ n/cm/sup 2/ to 2x10/sup 15/ m/cm/sup 2/. Discrete transistors, inverters, and ring oscillators were characterized at each fluence. While the MESFETs exhibit significant threshold voltage shifts and transconductance and saturation current degradation over this range of neutron fluences, the authors have observed improvement in the DC characteristics of Schottky Diode FET Logic (SDFL) inverters. This unusual result has been successfully simulated using device parameters extracted from FETs damaged by exposure to high energy neutrons. Although the decrease in device transconductance results in an increase in inverter gate delay, as reflected in ring oscillator frequency measurements, the authors conclude that GaAs ICs fabricated from this logic family will remain functional after exposure to extreme neutron fluences. This is a consequence of the observed improvement in inverter noise margin evident in both measured and simulated circuit performance

  4. Fast Reactive Power Sharing, Circulating Current and Resonance Suppression for Parallel Inverters Using Resistive-Capacitive Output Impedance

    DEFF Research Database (Denmark)

    Chen, Yandong; Guerrero, Josep M.; Shuai, Zhikang

    2016-01-01

    In this paper, an inverter using resistivecapacitive output impedance (RC-type inverter) is proposed not only to provide fast reactive power sharing to support microgrid voltage, and but also to reduce circulating currents and damp high-frequency resonances among inverters. Introducing the RC......-frequency resonances among parallel inverters are quantitatively analyzed. The control parameters are systematically selected, and effect of virtual complex impedance on the inverter output voltage is depicted. The RC-type inverter can reduce circulating currents and damp resonances due to different equivalent output...

  5. Harmonic mitigation in islanded microgrids by inverter-interfaced distributed energy resource

    Energy Technology Data Exchange (ETDEWEB)

    Xiongfei Wang

    2012-10-15

    An exciting growth of microgrids market has been witnessed around the world, driven on one hand by the increasing deployment of Distributed Energy Resource (DER) and on the other hand by the ongoing transformations of electric power systems towards more decentralized, intelligent, and resilient networks. The ability of dynamic islanding furnishes microgrids a prominent feature, which not only contributes to a more reliable electricity supply but also provides a systematic way to maximize the benefits of DER units for both customers and utilities. However, during islanded operations, microgrids are more sensitive to power quality disturbances, owing to the low short circuit ratio and limited capacity of DER units. As a consequence, harmonic distortion caused by the proliferation of nonlinear electronic equipment becomes more apparent. The recently released IEEE 1547 series standards have outlined the acceptable harmonic voltage and current distortion limits for islanded operations of microgrids. This thesis concentrates on developing advanced control algorithms for DER inverters in order to provide active harmonic conditioning services, including harmonic voltage reduction, harmonic current filtering and resonance damping in islanded microgrids. The research work is composed of two main parts. The first part is concerned with building a stable islanded microgrid, where the reduction of circulating current in the parallel DER inverters is studied. The second part addresses the harmonic distortion resulting from nonlinear loads and shunt-connected capacitors via the different control algorithms of DER inverters. Furthermore, to establish the basic control aspects for the islanded microgrid built in this project, a wide variety of control schemes for DER inverters within an islanded microgrid environment are evaluated. The merits and demerits of the different control methods are discussed. In light of this, the hierarchical control system is adopted, including the

  6. Selective Dirac voltage engineering of individual graphene field-effect transistors for digital inverter and frequency multiplier integrations

    Science.gov (United States)

    Sul, Onejae; Kim, Kyumin; Jung, Yungwoo; Choi, Eunsuk; Lee, Seung-Beck

    2017-09-01

    The ambipolar band structure of graphene presents unique opportunities for novel electronic device applications. A cycle of gate voltage sweep in a conventional graphene transistor produces a frequency-doubled output current. To increase the frequency further, we used various graphene doping control techniques to produce Dirac voltage engineered graphene channels. The various surface treatments and substrate conditions produced differently doped graphene channels that were integrated on a single substrate and multiple Dirac voltages were observed by applying a single gate voltage sweep. We applied the Dirac voltage engineering techniques to graphene field-effect transistors on a single chip for the fabrication of a frequency multiplier and a logic inverter demonstrating analog and digital circuit application possibilities.

  7. Selective Dirac voltage engineering of individual graphene field-effect transistors for digital inverter and frequency multiplier integrations.

    Science.gov (United States)

    Sul, Onejae; Kim, Kyumin; Jung, Yungwoo; Choi, Eunsuk; Lee, Seung-Beck

    2017-09-15

    The ambipolar band structure of graphene presents unique opportunities for novel electronic device applications. A cycle of gate voltage sweep in a conventional graphene transistor produces a frequency-doubled output current. To increase the frequency further, we used various graphene doping control techniques to produce Dirac voltage engineered graphene channels. The various surface treatments and substrate conditions produced differently doped graphene channels that were integrated on a single substrate and multiple Dirac voltages were observed by applying a single gate voltage sweep. We applied the Dirac voltage engineering techniques to graphene field-effect transistors on a single chip for the fabrication of a frequency multiplier and a logic inverter demonstrating analog and digital circuit application possibilities.

  8. Magneto-optical tweezers built around an inverted microscope

    International Nuclear Information System (INIS)

    Claudet, Cyril; Bednar, Jan

    2005-01-01

    We present a simple experimental setup of magneto-optical tweezers built around an inverted microscope. Two pairs of coils placed around the focal point of the objective generate a planar-rotating magnetic field that is perpendicular to the stretching direction. This configuration allows us to control the rotary movement of a paramagnetic bead trapped in the optical tweezers. The mechanical design is universal and can be simply adapted to any inverted microscope and objective. The mechanical configuration permits the use of a rather large experimental cell and the simple assembly and disassembly of the magnetic attachment

  9. Grid-Voltage-Feedforward Active Damping for Grid-Connected Inverter with LCL Filter

    DEFF Research Database (Denmark)

    Lu, Minghui; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    For the grid-connected voltage source inverters, the feedforward scheme of grid voltage is commonly adopted to mitigate the current distortion caused by grid background voltages harmonics. This paper investigates the grid-voltage-feedforward active damping for grid connected inverter with LCL...... filter. It reveals that proportional feedforward control can not only fulfill the mitigation of grid disturbance, but also offer damping effects on the LCL filter resonance. Digital delays are intrinsic to digital controlled inverters; with these delays, the feedforward control can be equivalent...

  10. Droop-Controlled Inverters with Seamless Transition between Islanding and Grid-Connected Operations

    DEFF Research Database (Denmark)

    Hu, Shang-Hung; Kuo, Chun-Yi; Lee, Tzung-Lin

    2011-01-01

    This paper presents a seamless transition method for droop-controlled inverters to operate in both islanding and grid-connected modes. A local PLL and a virtual inductance are designed to ride through transient when the inverter switches between two modes with no synchronization. The proposed...... method can cooperatively work with well-developed droop controls so that the inverters are able to share load among them as well as subsist under transient events of the utility. Theoretical analysis and experimental results validate effectiveness of the proposed method....

  11. A new inverter topology using GTO commutation. [Gate Turn Off thyristor

    Science.gov (United States)

    Rippel, W. E.

    1983-01-01

    A new N-phase, forced commutated bridge inverter topology has been developed wherein a single Gate Turn Off Thyristor (GTO) is used to commutate each of 2N main Thyristors (SCRs). Since, for most applications, the primary loss mechanism is the SCR forward drop, very high efficiencies are possible. Compared with conventional pure SCR and pure GTO inverters, cost per kW is lower - in the former case due to the large cost differential between GTOs and SCRs. Other advantages of the new inverter include high power density, low switching losses and stresses, modulation flexibility and amenability to high voltage and high frequency operation.

  12. Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Liu, Wenzhao; Zhang, X.

    2014-01-01

    This paper presents the theoretical analysis of the inherent reason of current harmonic and power oscillation phenomena in case of operating the microgrid inverter under unbalanced grid voltage conditions. In order to flexibly control the current harmonic and power oscillation, a new stationary...... inverter. Finally, the performance evaluation tests are carried out under unbalanced grid voltage conditions. Results verify the effectiveness of the propose method....

  13. Modeling, numerical simulation, and nonlinear dynamic behavior analysis of PV microgrid-connected inverter with capacitance catastrophe

    Science.gov (United States)

    Li, Sichen; Liao, Zhixian; Luo, Xiaoshu; Wei, Duqu; Jiang, Pinqun; Jiang, Qinghong

    2018-02-01

    The value of the output capacitance (C) should be carefully considered when designing a photovoltaic (PV) inverter since it can cause distortion in the working state of the circuit, and the circuit produces nonlinear dynamic behavior. According to Kirchhoff’s laws and the characteristics of an ideal operational amplifier for a strict piecewise linear state equation, a circuit simulation model is constructed to study the system parameters (time, C) for the current passing through an inductor with an inductance of L and the voltage across the capacitor with a capacitance of C. The developed simulation model uses Runge-Kutta methods to solve the state equations. This study focuses on predicting the fault of the circuit from the two aspects of the harmonic distortion and simulation results. Moreover, the presented model is also used to research the working state of the system in the case of a load capacitance catastrophe. The nonlinear dynamic behaviors in the inverter are simulated and verified.

  14. Improved Reliability of Single-Phase PV Inverters by Limiting the Maximum Feed-in Power

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    Grid operation experiences have revealed the necessity to limit the maximum feed-in power from PV inverter systems under a high penetration scenario in order to avoid voltage and frequency instability issues. A Constant Power Generation (CPG) control method has been proposed at the inverter level...... devices, allowing a quantitative prediction of the power device lifetime. A study case on a 3 kW single-phase PV inverter has demonstrated the advantages of the CPG control in terms of improved reliability.......Grid operation experiences have revealed the necessity to limit the maximum feed-in power from PV inverter systems under a high penetration scenario in order to avoid voltage and frequency instability issues. A Constant Power Generation (CPG) control method has been proposed at the inverter level....... The CPG control strategy is activated only when the DC input power from PV panels exceeds a specific power limit. It enables to limit the maximum feed-in power to the electric grids and also to improve the utilization of PV inverters. As a further study, this paper investigates the reliability performance...

  15. Electronic Document Management Using Inverted Files System

    Science.gov (United States)

    Suhartono, Derwin; Setiawan, Erwin; Irwanto, Djon

    2014-03-01

    The amount of documents increases so fast. Those documents exist not only in a paper based but also in an electronic based. It can be seen from the data sample taken by the SpringerLink publisher in 2010, which showed an increase in the number of digital document collections from 2003 to mid of 2010. Then, how to manage them well becomes an important need. This paper describes a new method in managing documents called as inverted files system. Related with the electronic based document, the inverted files system will closely used in term of its usage to document so that it can be searched over the Internet using the Search Engine. It can improve document search mechanism and document save mechanism.

  16. Electronic Document Management Using Inverted Files System

    Directory of Open Access Journals (Sweden)

    Suhartono Derwin

    2014-03-01

    Full Text Available The amount of documents increases so fast. Those documents exist not only in a paper based but also in an electronic based. It can be seen from the data sample taken by the SpringerLink publisher in 2010, which showed an increase in the number of digital document collections from 2003 to mid of 2010. Then, how to manage them well becomes an important need. This paper describes a new method in managing documents called as inverted files system. Related with the electronic based document, the inverted files system will closely used in term of its usage to document so that it can be searched over the Internet using the Search Engine. It can improve document search mechanism and document save mechanism.

  17. Rayleigh instability of the inverted one-cell amphibian embryo

    International Nuclear Information System (INIS)

    Nouri, Comron; Gordon, Richard; Luppes, Roel; Veldman, Arthur E P; Tuszynski, Jack A

    2008-01-01

    The one-cell amphibian embryo is modeled as a rigid spherical shell containing equal volumes of two immiscible fluids with different densities and viscosities and a surface tension between them. The fluids represent denser yolk in the bottom hemisphere and clearer cytoplasm and the germinal vesicle in the top hemisphere. The unstable equilibrium configuration of the inverted system (the heavier fluid on top) depends on the value of the contact angle. The theoretically calculated normal modes of perturbation and the instability of each mode are in agreement with the results from ComFlo computational fluid dynamic simulations of the same system. The two dominant types of modes of perturbation give rise to axisymmetric and asymmetric sloshing of the cytoplasm of the inverted embryos, respectively. This work quantifies our hypothesis that the axisymmetric mode corresponds to failure of development, and the asymmetric sloshing mode corresponds to development proceeding normally, but with reversed pigmentation, for inverted embryos

  18. The 50 kV inverted source of polarized electrons at ELSA

    International Nuclear Information System (INIS)

    Hillert, Wolfgang; Gowin, Michael; Neff, Berhold

    2001-01-01

    The future medium energy physics program at the electron stretcher accelerator ELSA of Bonn University mainly relies on experiments requiring a beam of polarized electrons and a polarized target. To provide a polarized beam with high polarization and sufficient intensity a pulsed 50 kV inverted gun of polarized electrons has been set into operation. The gun is operated in space charge limitation, producing a peak current of 100 mA in rectangular 1μs long electron pulses. Photocathode lifetime during operation is higher than 3000 hours. Using a Be-InGaAs/Be-AlGaAs superlattice photocathode a polarization of 80% and a corresponding quantum efficiency of 0.4% could be obtained

  19. 2.3-MW Medium-Voltage, Three-Level Wind Energy Inverter Applying a Unique Bus Structure and 4.5-kV Si/SiC Hybrid Isolated Power Modules: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, W.; Keller, J.; Grider, D.; VanBrunt, E.

    2014-11-01

    A high-efficiency, 2.3-MW, medium-voltage, three-level inverter utilizing 4.5-kV Si/SiC (silicon carbide) hybrid modules for wind energy applications is discussed. The inverter addresses recent trends in siting the inverter within the base of multimegawatt turbine towers. A simplified split, three-layer laminated bus structure that maintains low parasitic inductances is introduced along with a low-voltage, high-current test method for determining these inductances. Feed-thru bushings, edge fill methods, and other design features of the laminated bus structure provide voltage isolation that is consistent with the 10.4-kV module isolation levels. Inverter efficiency improvement is a result of the (essential) elimination of the reverse recovery charge present in 4.5-kV Si PIN diodes, which can produce a significant reduction in diode turn-off losses as well as insulated-gate bipolar transistor (IGBT) turn-on losses. The hybrid modules are supplied in industry-standard 140 mm x 130 mm and 190 mm x 130 mm packages to demonstrate direct module substitution into existing inverter designs. A focus on laminated bus/capacitor-bank/module subassembly level switching performance is presented.

  20. Fault Ride-Through of a Grid-connected Photovoltaic System with Quasi Z Source Inverter

    DEFF Research Database (Denmark)

    Al-Durra, Ahmed; Fayyad, Yara; Muyeen, S.M.

    2016-01-01

    This article presents fault ride-through schemes for a three-phase quasi Z source single-stage photovoltaic (PV) inverter that is connected to the grid after the distribution network. The quasi Z source inverter employs a unique LC network to couple the inverter main circuit to the input of the PV...... the grid side so that the grid fault ride-through requirements can be fulfilled. Scheme A involves control modification in the system; Schemes B and C involve hardware modification in the circuit topology by adding a chopper circuit across the DC link in Scheme B and across the quasi Z source inverter...

  1. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ralph, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as

  2. SiC MOSFETs based split output half bridge inverter

    DEFF Research Database (Denmark)

    Li, Helong; Munk-Nielsen, Stig; Beczkowski, Szymon

    2014-01-01

    output. The double pulse test shows the devices' current during commutation process and the reduced switching losses of SiC MOSFETs compared to that of the traditional half bridge. The efficiency comparison is presented with experimental results of half bridge power inverter with split output...... and traditional half bridge inverter, from switching frequency 10 kHz to 100 kHz. The experimental results comparison shows that the half bridge with split output has an efficiency improvement of more than 0.5% at 100 kHz switching frequency....

  3. A digital output accelerometer using MEMS-based piezoelectric accelerometers and arrayed CMOS inverters with satellite capacitors

    International Nuclear Information System (INIS)

    Kobayashi, T; Okada, H; Maeda, R; Itoh, T; Masuda, T

    2011-01-01

    The present paper describes the development of a digital output accelerometer composed of microelectromechanical systems (MEMS)-based piezoelectric accelerometers and arrayed complementary metal–oxide–semiconductor (CMOS) inverters accompanied by capacitors. The piezoelectric accelerometers were fabricated from multilayers of Pt/Ti/PZT/Pt/Ti/SiO 2 deposited on silicon-on-insulator (SOI) wafers. The fabricated piezoelectric accelerometers were connected to arrayed CMOS inverters. Each of the CMOS inverters was accompanied by a capacitor with a different capacitance called a 'satellite capacitor'. We have confirmed that the output voltage generated from the piezoelectric accelerometers can vary the output of the CMOS inverters from a high to a low level; the state of the CMOS inverters has turned from the 'off-state' into the 'on-state' when the output voltage of the piezoelectric accelerometers is larger than the threshold voltage of the CMOS inverters. We have also confirmed that the CMOS inverters accompanied by the larger satellite capacitor have become 'on-state' at a lower acceleration. On increasing the acceleration, the number of on-state CMOS inverters has increased. Assuming that the on-state and off-state of CMOS inverters correspond to logic '0' and '1', the present digital output accelerometers have expressed the accelerations of 2.0, 3.0, 5.0, and 5.5 m s −2 as digital outputs of 111, 110, 100, and 000, respectively

  4. Reflex responses in the lower leg following landing impact on an inverting and non-inverting platform.

    NARCIS (Netherlands)

    Grüneberg, C.; Nieuwenhuijzen, P.H.J.A.; Duysens, J.E.J.

    2003-01-01

    In the lower leg, landing after a jump induces reflexes, the role of which is not well understood. This is even more so for reflexes following landing on inverting surfaces. The latter condition is of special interest since ankle inversion traumata are one of the most common injuries during sport.

  5. An improved modulation strategy for the three-phase Z-source inverters (ZSIs)

    DEFF Research Database (Denmark)

    Abdelhakim, Ahmed; Davari, Pooya; Blaabjerg, Frede

    2017-01-01

    Z-source inverters (ZSIs), compared to the two-stage architecture, i.e. boost-converter (BC)-fed voltage source inverter (VSI), embrace some interesting features, like the reduced size and complexity of the entire conversion system. Several research activities have been established to improve...

  6. Grid-connected inverter for wind power generation system

    Institute of Scientific and Technical Information of China (English)

    YANG Yong; RUAN Yi; SHEN Huan-qing; TANG Yan-yan; YANG Ying

    2009-01-01

    In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on PI-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.

  7. Invertible chaotic fragile watermarking for robust image authentication

    International Nuclear Information System (INIS)

    Sidiropoulos, Panagiotis; Nikolaidis, Nikos; Pitas, Ioannis

    2009-01-01

    Fragile watermarking is a popular method for image authentication. In such schemes, a fragile signal that is sensitive to manipulations is embedded in the image, so that it becomes undetectable after any modification of the original work. Most algorithms focus either on the ability to retrieve the original work after watermark detection (invertibility) or on detecting which image parts have been altered (localization). Furthermore, the majority of fragile watermarking schemes suffer from robustness flaws. We propose a new technique that combines localization and invertibility. Moreover, watermark dependency on the original image and the non-linear watermark embedding procedure guarantees that no malicious attacks will manage to create information leaks.

  8. Inverter-based successive approximation capacitance-to-digital converter

    KAUST Repository

    Omran, Hesham

    2017-03-23

    An energy-efficient capacitance-to-digital converter (CDC) is provided that utilizes a capacitance-domain successive approximation (SAR) technique. Unlike SAR analog- to-digital converters (ADCs), analysis shows that for SAR CDCs, the comparator offset voltage will result in signal-dependent and parasitic-dependent conversion errors, which necessitates an op-amp-based implementation. The inverter-based SAR CDC contemplated herein provides robust, energy-efficient, and fast operation. The inverter- based SAR CDC may include a hybrid coarse-fine programmable capacitor array. The design of example embodiments is insensitive to analog references, and thus achieves very low temperature sensitivity without the need for calibration. Moreover, this design achieves improved energy efficiency.

  9. Model predictive control for a dual active bridge inverter with a floating bridge

    OpenAIRE

    Chowdhury, Shajjad; Wheeler, Patrick W.; Gerada, C.; Patel, Chintan

    2016-01-01

    This paper presents a Model Predictive Control technique applied to a dual active bridge inverter where one of the bridges is floating. The proposed floating bridge topology eliminates the need for isolation transformer in a dual inverter system and therefore reduces the size, weight and losses in the system. To achieve multilevel output voltage waveforms the floating inverter DC link capacitor is charged to the half of the main DC link voltage. A finite-set Model Predictive Control technique...

  10. Asymmetric power device rating selection for even temperature distribution in NPC inverter

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede

    2017-01-01

    the power rating and lifetime of the NPC inverter are limited by the most stressed devices. In this paper, an asymmetric power device rating selection method for the NPC inverter is proposed in order to balance the lifetimes of the power devices. The thermal distribution of the power devices is analyzed......A major drawback of the NPC inverter is an unequal power loss distribution among the power devices which leads to unequal temperature stress among them. Therefore, certain power devices experience higher temperature stress, which is the main cause of power device module failure and thus both...... based on 30 kW NPC inverter as a case study. Analytical power loss and thermal impedance models depending on the chip size are derived. Finally, using these models, the junction temperatures of the power devices depending on the chip size is discussed and a proper chip size for an even temperature...

  11. Grid-connected Photovoltaic Micro-inverter with New Hybrid Control LLC Resonant Converter

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Qingbo, Ke

    2016-01-01

    A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse-frequency modulat......A high-efficiency photovoltaic (PV) micro-inverter consisting of two power stages i.e. a LLC resonant converter with a new hybrid control scheme and a dc-ac inverter is proposed, studied and designed in this paper. In the first power stage, the new hybrid control combining pulse......-frequency modulation (PFM) and phase-shift pulse-width modulation (PS-PWM) is employed on a full-bridge LLC dc-dc converter, in order to achieve high efficiency when PV output voltage varies in a wide range. Moreover, a maximum power point tracking (MPPT) method based on power perturbation is implemented in the dc...

  12. Inverted temperature sequences: role of deformation partitioning

    Science.gov (United States)

    Grujic, D.; Ashley, K. T.; Coble, M. A.; Coutand, I.; Kellett, D.; Whynot, N.

    2015-12-01

    The inverted metamorphism associated with the Main Central thrust zone in the Himalaya has been historically attributed to a number of tectonic processes. Here we show that there is actually a composite peak and deformation temperature sequence that formed in succession via different tectonic processes. The deformation partitioning seems to the have played a key role, and the magnitude of each process has varied along strike of the orogen. To explain the formation of the inverted metamorphic sequence across the Lesser Himalayan Sequence (LHS) in eastern Bhutan, we used Raman spectroscopy of carbonaceous material (RSCM) to determine the peak metamorphic temperatures and Ti-in-quartz thermobarometry to determine the deformation temperatures combined with thermochronology including published apatite and zircon U-Th/He and fission-track data and new 40Ar/39Ar dating of muscovite. The dataset was inverted using 3D-thermal-kinematic modeling to constrain the ranges of geological parameters such as fault geometry and slip rates, location and rates of localized basal accretion, and thermal properties of the crust. RSCM results indicate that there are two peak temperature sequences separated by a major thrust within the LHS. The internal temperature sequence shows an inverted peak temperature gradient of 12 °C/km; in the external (southern) sequence, the peak temperatures are constant across the structural sequence. Thermo-kinematic modeling suggest that the thermochronologic and thermobarometric data are compatible with a two-stage scenario: an Early-Middle Miocene phase of fast overthrusting of a hot hanging wall over a downgoing footwall and inversion of the synkinematic isotherms, followed by the formation of the external duplex developed by dominant underthrusting and basal accretion. To reconcile our observations with the experimental data, we suggest that pervasive ductile deformation within the upper LHS and along the Main Central thrust zone at its top stopped at

  13. Space Vector Pulse Width Modulation Strategy for Single-Phase Three-Level CIC T-source Inverter

    DEFF Research Database (Denmark)

    Shults, Tatiana E.; Husev, Oleksandr O.; Blaabjerg, Frede

    2016-01-01

    This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance of the inver......This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance...... of the inverter, the strategy was compared the traditional pulse-width modulation. It is shown that the approach proposed has fewer switching states and does not suffer from neutral point misbalance....

  14. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  15. Power Control Flexibilities for Grid-Connected Multi-Functional Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2016-01-01

    and intelligent services, such as fault ride-through and reactive power compensation, is the key to attain higher utilisation of solar PV energy. Such functionalities for the future PV inverters can contribute to reduced cost of energy, and thus enable more cost-effective PV installations. To implement...... the advanced features, a flexible power controller is developed in this study, which can be configured in the PV inverter and flexibly change from one to another mode during operation. Based on the single-phase PQ theory, the control strategy offers the possibilities to generate appropriate references...... for the inner current control loop. The references depend on system conditions and also specific demands from both system operators and prosumers. Besides, this power control strategy can be implemented in commercial PV inverters as a standardised function, and also the operation modes can be achieved online...

  16. Power control flexibilities for grid-connected multi-functional photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Wang, Huai

    2014-01-01

    to reduced cost of energy. To implement the advanced features, a flexible power controller is developed in this paper, which can be configured in the PV inverter and flexibly be changed from one to another. This power control strategy is based on the single-phase PQ theory, and it offers the possibilities...... of ancillary and intelligent services, like Low Voltage Ride-Through (LVRT), reactive power compensation, and reliability-oriented thermal management/control by PV systems is a key to attain higher utilization of solar energy. Those essential functionalities for the future PV inverters can contribute...... to generate appropriate references for the inner current control loop. The references depend on the system conditions and also specific demands from both system operators and customers. Besides, this power control strategy can be implemented in a commercial PV inverter as standardized functions, and also...

  17. Hydrodynamic stability of inverted annular flow in an adiabatic simulation

    International Nuclear Information System (INIS)

    De Jarlais, G.; Ishii, M.; Linehan, J.

    1986-01-01

    Inverted annular flow was simulated adiabatically with turbulent water jets, issuing downward from large aspect ratio nozzles, enclosed in gas annuli. Velocities, diameters, and gas species were varied, and core jet length, shape, breakup mode, and dispersed core droplet sizes were recorded at approximately 750 data points. Inverted annular flow destabilization led to inverted slug flow at low relative velocities, and to dispersed droplet flow, core breakup length correlations were developed by extending work on free liquid jets to include this coaxial, jet disintegration phenomenon. The results show length dependence upon D/sub J/, Re/sub J/, We/sub J/, α, and We/sub G/,rel. Correlations for core shape, breakup mechanisms, and dispersed core droplet size were also developed, by extending the results of free jet stability, roll wave entrainment, and churn turbulent droplet stability studies

  18. Lifetime Evaluation of Grid-Connected PV Inverters Considering Panel Degradation Rates and Installation Sites

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso

    2018-01-01

    Lifetime of PV inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels, and thus long-term energy production...... and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper thus evaluates the lifetime of PV inverters considering panel degradation rates and mission profiles. Evaluations have been carried out on PV systems installed in Denmark...... and Arizona. The results reveal that the PV panel degradation rate has a considerable impact on the PV inverter lifetime, especially in the hot climate (e.g., Arizona), where the panel degrades at a faster rate. In that case, the PV inverter lifetime prediction can be deviated by 54%, if the impact of PV...

  19. Cross-Circulating Current Suppression Method for Parallel Three-Phase Two-Level Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Guo, Xiaoqiang

    2015-01-01

    The parallel architecture is very popular for power inverters to increase the power level. This paper presents a method for the parallel operation of inverters in an ac-distributed system, to suppress the cross-circulating current based on virtual impedance without current-sharing bus...

  20. Single phase cascaded H5 inverter with leakage current elimination for transformerless photovoltaic system

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Jia, X.; Lu, Z.

    2016-01-01

    Leakage current reduction is one of the important issues for the transformelress PV systems. In this paper, the transformerless single-phase cascaded H-bridge PV inverter is investigated. The common mode model for the cascaded H4 inverter is analyzed. And the reason why the conventional cascade H4...... inverter fails to reduce the leakage current is clarified. In order to solve the problem, a new cascaded H5 inverter is proposed to solve the leakage current issue. Finally, the experimental results are presented to verify the effectiveness of the proposed topology with the leakage current reduction...... for the single-phase transformerless PV systems....

  1. Waveform control method for mitigating harmonics of inverter systems with nonlinear load

    DEFF Research Database (Denmark)

    Wang, Haoran; Zhu, Guorong; Fu, Xiaobin

    2015-01-01

    instability in the DC power system, lower its efficiency, and shorten the lifetime of the DC source. This paper presents a general waveform control method that can mitigate the injection of the low-frequency ripple current by the single-phase DC/AC inverter into the DC source. It also discusses the inhibiting......DC power systems connecting to single-phase DC/AC inverters with nonlinear loads will have their DC sources being injected with AC ripple currents containing a low-frequency component at twice the output voltage frequency of the inverter and also other current harmonics. Such a current may create...

  2. Design And Implementation Of Cost Effective Inverter

    Directory of Open Access Journals (Sweden)

    Niaz Morshedul Haque

    2017-10-01

    Full Text Available This paper deals with the design and construct of a 100 Watt 220 Volt and 50 Hz Inverter. The system is designed without any microcontroller and it has a cost-effective design architecture. The elementary purpose of this device is to transmute 12 V DC to 220 V AC. Snubber technology is used to diminish the reverse potential transients and excessive heat of transformer winding and transistor switches. Switching pulse generated by NE 555 timer circuit and comparator circuit was used to take signal strength input from its rear as well as from both sides for triggering the MOSFET switches. Another switch is used to invert pulse between two switching circuitries. A 5 volts regulator IC 7805 was used to supply fixed 5V for biasing the switching and amplifying circuitry.

  3. Inverted U-shaped model: How frequent repetition affects perceived risk

    OpenAIRE

    Xi Lu; Xiaofei Xie; Lu Liu

    2015-01-01

    We asked how repeated media reports on technological hazards influence an individual's risk perception. We looked for two contradictory effects, an increasing effect of repetition on perceived risk with the first few repetitions and a decreasing effect with later repetitions, leading to the inverted U-shaped pattern. In an experiment, we demonstrated the inverted U-shaped relationship between the repetition and perceived risk in the context of food risk. The finding broaden...

  4. Current-type flipped-Γ-source inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Li, Ding; Blaabjerg, Frede

    2012-01-01

    are of interest since they use lesser components. Their winding turns might however become too excessive for higher demanded gains. Avoiding this usual trend, a new family of current-type flipped-Γ-source inverters are proposed, whose common gain is raised by lowering, and not increasing, the winding turns...

  5. Inverter Matrix for the Clementine Mission

    Science.gov (United States)

    Buehler, M. G.; Blaes, B. R.; Tardio, G.; Soli, G. A.

    1994-01-01

    An inverter matrix test circuit was designed for the Clementine space mission and is built into the RRELAX (Radiation and Reliability Assurance Experiment). The objective is to develop a circuit that will allow the evaluation of the CMOS FETs using a lean data set in the noisy spacecraft environment.

  6. Cascaded impedance networks for NPC inverter

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    they are subject to the renewable sources. To date, three distinct types of impedance networks can be summarized for implementing a hybrid source impedance network, which can in principle be combined and cascaded before connected to a NPC inverter by proposed two ways. The resulting cascaded impedance network NPC...

  7. Tuning the ITO work function by capacitively coupled plasma and its application in inverted organic solar cells

    International Nuclear Information System (INIS)

    Fang, Ming; Zhang, Chunmei; Chen, Qiang

    2016-01-01

    Highlights: • The work function of ITO was reduced by plasma treatment. • The reduction of the work function was attributed to the variation in chemical component of ITO surface. • The inverted solar cell without electron transport layer was fabricated using plasma-treated ITO. • Optimal power conversion efficiency of 3.22% was achieved. - Abstract: In this paper, we investigated the performance of inverted organic solar cells (OSCs) with plasma-treated indium tin oxide (ITO) as the cathode for omitting an electron transport layer. The Ar plasma was produced by capcitively coupled plasma setup under 20 Pa chamber pressure. For the device with the structure of plasma-treated ITO/P3HT:PCBM/MoO_3/Ag, a power conversion efficiency (PCE) of 3.22% was achieved, whereas PCE of 1.13% was recorded from the device fabricated with the pristine ITO. The photovoltaic performance was found to be dependent on the applied power of plasma. After analyzing by atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), we concluded that the chemical component variation of ITOs surface resulted in the decrease of ITO work function, which meant that the ITO Fermi level became shallow relative to the vacuum level. The low work function of ITO should be responsible for the improvement of inverted OSCs because of the better energy level alignment between ITO and the photoactive layer.

  8. Tuning the ITO work function by capacitively coupled plasma and its application in inverted organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Ming [Laboratory of Plasma Physics and Materials, Beijing Institute of Graphic Communication, Beijing (China); Zhang, Chunmei, E-mail: zhangchunmei@bigc.edu.cn [Laboratory of Plasma Physics and Materials, Beijing Institute of Graphic Communication, Beijing (China); Chen, Qiang [Laboratory of Plasma Physics and Materials, Beijing Institute of Graphic Communication, Beijing (China); State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an (China)

    2016-11-01

    Highlights: • The work function of ITO was reduced by plasma treatment. • The reduction of the work function was attributed to the variation in chemical component of ITO surface. • The inverted solar cell without electron transport layer was fabricated using plasma-treated ITO. • Optimal power conversion efficiency of 3.22% was achieved. - Abstract: In this paper, we investigated the performance of inverted organic solar cells (OSCs) with plasma-treated indium tin oxide (ITO) as the cathode for omitting an electron transport layer. The Ar plasma was produced by capcitively coupled plasma setup under 20 Pa chamber pressure. For the device with the structure of plasma-treated ITO/P3HT:PCBM/MoO{sub 3}/Ag, a power conversion efficiency (PCE) of 3.22% was achieved, whereas PCE of 1.13% was recorded from the device fabricated with the pristine ITO. The photovoltaic performance was found to be dependent on the applied power of plasma. After analyzing by atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS), we concluded that the chemical component variation of ITOs surface resulted in the decrease of ITO work function, which meant that the ITO Fermi level became shallow relative to the vacuum level. The low work function of ITO should be responsible for the improvement of inverted OSCs because of the better energy level alignment between ITO and the photoactive layer.

  9. Inverting the Telescope on Borders that Matter: Conversations in Café Europa

    NARCIS (Netherlands)

    Anderson, D.J.; Kramsch, O.T.; Sandberg, M.

    2015-01-01

    Proposing an ‘inverted telescope’ for border studies, we problematized existing calls to ‘see like a border’, arguing that such moves miss an opportunity to define what is properly political about b/ordering space. Inverting the telescope on borders that matter reveals an ontologically grounded

  10. Grid-connected photovoltaic power systems: survey of inverter and related protection equipments

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T

    2002-12-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme reports on a survey made on inverter and related protection equipment. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This report summarises the data obtained from survey of recent inverter technology and inverter protection equipment for grid interconnected PV systems. The results are based on the surveys using a questionnaire to identify the current status of grid-interconnection inverters. This report is to serve as a reference for those interested in installing grid-connected PV systems, electric utility company personnel, manufacturers and researchers. The results of the survey are presented and discussed. Technical and financial data is reviewed and two appendices provide details on the results obtained and those institutions involved in the survey.

  11. A unified grid current control for grid-interactive DG inverters in microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittan...... locus analyses in the discrete z-domain are performed for elaborating the controller design. Simulations and experimental results demonstrate the performances of the proposed approach.......This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittance...... in the outer loop. It, therefore, provides several superior features over traditional control schemes: 1) high-quality grid current in the grid-connected mode, 2) inherent derivative-less virtual output impedance control, and 3) the unified active damping for both grid-connected and islanded operations. Root...

  12. 5kVa power inverter design and simulation based on boost ...

    African Journals Online (AJOL)

    Five (5) kVA power inverter was designed and simulated base on two topologies; Boost converter and Half-bridge inverter topology. A 555 timer IC was used as the control at fixed frequencies of 25 kHz and 50 Hz for the two stages. The results of the simulation were obtained. The graphs for both stages were plotted and the ...

  13. Comparison of Output Current Ripple in Single and Dual Three-Phase Inverters for Electric Vehicle Motor Drives

    Directory of Open Access Journals (Sweden)

    Jelena Loncarski

    2015-04-01

    Full Text Available The standard solution for the traction system in battery powered electric vehicles (EVs is a two-level (2L inverter feeding a three-phase motor. A simple and effective way to achieve a three-level (3L inverter in battery-supplied electric vehicles consists of using two standard three-phase 2L inverters with the open-end winding connection of standard three-phase ac motors. The 3L inverter solution can be usefully adopted in EVs since it combines several benefits such as current ripple reduction, increment of phase motor voltage with limited voltage ratings of the two battery banks, improvement in system reliability, etc. The reduction in current ripple amplitude is particularly relevant since it is a source of electromagnetic interference and audio noise from the inverter-motor power connection cables and from the motor itself. By increasing the inverter switching frequency the ripple amplitude is reduced, but the drive efficiency decreases due to the proportionally increased switching losses. In this paper the peak-to-peak ripple amplitude of the dual-2L inverter is evaluated and compared with the corresponding ripple of the single-2L inverter, considering the same voltage and power motor ratings. The ripple analysis is carried out as a function of the modulation index to cover the whole modulation range of the inverter, and the theoretical results are verified with experimental tests carried out by an inverter-motor drive prototype.

  14. A novel harmonic current sharing control strategy for parallel-connected inverters

    DEFF Research Database (Denmark)

    Guan, Yajuan; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    A novel control strategy which enables proportional linear and nonlinear loads sharing among paralleled inverters and voltage harmonic suppression is proposed in this paper. The proposed method is based on the autonomous currents sharing controller (ACSC) instead of conventional power droop control...... to provide fast transient response, decoupling control and large stability margin. The current components at different sequences and orders are decomposed by a multi-second-order generalized integrator-based frequency locked loop (MSOGI-FLL). A harmonic-orthogonal-virtual-resistances controller (HOVR......) is used to proportionally share current components at different sequences and orders independently among the paralleled inverters. Proportional resonance controllers tuned at selected frequencies are used to suppress voltage harmonics. Simulations based on two 2.2 kW paralleled three-phase inverters...

  15. A New Configuration for Power Sharing of Two Z-Source Inverters

    Directory of Open Access Journals (Sweden)

    M. Ghani varzaneh

    2017-09-01

    Full Text Available This paper presents a new structure to provide the ability for power sharing of two Z-source inverters. According to the operation principles of Z-source inverters, only one input source supplies the circuit, which is a limitation particularly for the stand alone systems feeded by limited output power such as photovoltaics and feul cells. Furthermore; if one source fails to supply,  the load can't be supplied. This paper covers those via interconnection of impedance network of two Z-source inverters. The operating principles of the proposed topology for the stand-alone and power sharing conditions are described and the relations are derived. The topology is simulated, which the results verify the theoretical analysis and well performance of the system. 

  16. The influences of load mass changing on inverted pendulum stability based on simulation study

    Science.gov (United States)

    Pangaribuan, Timbang; Nasruddin, M. N.; Marlianto, Eddy; Sigiro, Mula

    2017-09-01

    An inverted pendulum has nonlinear dynamic, so it is not easy to do in analysis to see its behavior. From many observations which have been made, there are two things that need to be added on the perfection of inverted pendulum. Firstly, when the pendulum has a large mass, and the second when the pendulum is given a load mass much larger than mass of the inverted pendulum. There are some question, first, how big the load mass can be given so that the movement of the inverted pendulum stay stable is. Second, how weight the changes and moves of load mass which can be given. For all the changes, it hopes the inverted pendulum is stay stable. Finally, the final result is still expected to be as stable, it must need conclude what kind of controller is capable of carrying such a mass burden, and how large the mass load limit can be given.

  17. Grid-Connected Control Strategy of Five-level Inverter Based on Passive E-L Model

    Directory of Open Access Journals (Sweden)

    Tao Li

    2017-10-01

    Full Text Available At present, the research on five-level inverters mainly involves the modulation algorithm and topology, and few articles study the five-level inverter from the control strategy. In this paper, the nonlinear passivity-based control (PBC method is proposed for single-phase uninterruptible power supply inverters. The proposed PBC method is based on an energy shaping and damping injection idea, which is performed to regulate the energy flow of an inverter to a desired level and to assure global asymptotic stability, respectively. Furthermore, this paper presents a control algorithm based on the theory of passivity that gives an inverter in a photovoltaic system additional functions: power factor correction, harmonic currents compensation, and the ability to stabilize the system under varying injection damping. Finally, the effectiveness of the PBC method in terms of both stability and harmonic distortion is verified by the simulation and experiments under resistive and inductive loads.

  18. Five-Level Current-Source Inverters With Buck–Boost and Inductive-Current Balancing Capabilities

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This paper presents new five-level current-source inverters (CSIs) with voltage/current buck–boost capability, unlike existing five-level CSIs where only voltage–boost operation is supported. The proposed inverters attain self-inductive-currentbalancing per switching cycle at their dc front ends...... without having to include additional balancing hardware or complex control manipulation. The inverters can conveniently be controlled by using the well-established phase-shifted carrier modulation scheme with only two additional linear references and a mapping logic table needed. Existing modulators can...

  19. Interaction Admittance Based Modeling of Multi-Paralleled Grid-Connected Inverter with LCL-Filter

    DEFF Research Database (Denmark)

    Lu, Minghui; Blaabjerg, Frede; Wang, Xiongfei

    2016-01-01

    This paper investigates the mutual interaction and stability issues of multi-parallel LCL-filtered inverters. The stability and power quality of multiple grid-tied inverters are gaining more and more research attention as the penetration of renewables increases. In this paper, interactions...... and coupling effects among the multi-paralleled inverters and power grid are explicitly revealed. An Interaction Admittance concept is introduced to express and model the interaction through the physical admittances of the network. Compared to the existing modeling methods, the proposed analysis provides...

  20. PV inverter test setup for European efficiency, static and dynamic MPPT efficiency evaluation

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Valentini, Massimo

    2008-01-01

    This paper concerns the evaluation of performance of grid-connected PV inverters in terms of conversion efficiency, European efficiency, static and dynamic MPP efficiency. Semi-automated tests were performed in the PV laboratory of the Institute of Energy Technology at the Aalborg University...... (Denmark) on a commercial transformerless PV inverter. Thanks to the available experimental test setups, that provide the required high measuring accuracy, and the developed PV simulator, which is required for MPPT performance evaluation, PV Inverters can be pretested before being tested by accredited...

  1. Dead Zone Oscillator Control for Communication-Free Synchronization of Paralleled, Three-Phase, Current-Controlled Inverters

    Science.gov (United States)

    2016-05-11

    Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab, USN UNITED STATES NAVAL ACADEMY...Three-Phase, Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab United States Naval Academy Annapolis, Maryland...for Communication-Free Synchronization of Paralleled, 5a. CONTRACT NUMBER Three-Phase, Current-Controlled Inverters 5b. GRANT NUMBER 5c

  2. A case report of inverted papilloma of the posterior urethra

    OpenAIRE

    徳光, 正行; 井内, 裕満; 森川, 満; 八竹, 直

    1992-01-01

    A case of inverted papilloma of the posterior urethra is reported. A 59-year-old male was admitted with the chief complaint of hematuria. Urethrogram revealed a small defect in the neck of the bladder. Endoscopic examination revealed a polypoid tumor on the stalk arising from prostatic urethra, and transurethral resection was performed. The patient has been subsequently followed up and there has been no evidence of recurrence. Although 141 cases of inverted papilloma have been reported in man...

  3. Improved control strategy for the three-phase grid-connected inverter

    DEFF Research Database (Denmark)

    Yao, Zhilei; Xiao, Lan; Guerrero, Josep M.

    2015-01-01

    An improved control strategy for the three-phase grid-connected inverter with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d- and q-axis grid currents will be interacted, and then the waveform quality of the grid current will be poorer....... As the reference output voltage cannot directly reflect the change of the reference grid current, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d- and q-axis grid currents in the decoupled components of the grid current controller can be substituted...... by the d- and q-axis reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results for a 15-kVA three-phase grid-connected inverter with SVPWM verify the theoretical analysis. Compared with the traditional control...

  4. A molybdenum disulfide/carbon nanotube heterogeneous complementary inverter.

    Science.gov (United States)

    Huang, Jun; Somu, Sivasubramanian; Busnaina, Ahmed

    2012-08-24

    We report a simple, bottom-up/top-down approach for integrating drastically different nanoscale building blocks to form a heterogeneous complementary inverter circuit based on layered molybdenum disulfide and carbon nanotube (CNT) bundles. The fabricated CNT/MoS(2) inverter is composed of n-type molybdenum disulfide (MOS(2)) and p-type CNT transistors, with a high voltage gain of 1.3. The CNT channels are fabricated using directed assembly while the layered molybdenum disulfide channels are fabricated by mechanical exfoliation. This bottom-up fabrication approach for integrating various nanoscale elements with unique characteristics provides an alternative cost-effective methodology to complementary metal-oxide-semiconductors, laying the foundation for the realization of high performance logic circuits.

  5. Signature Schemes Secure against Hard-to-Invert Leakage

    DEFF Research Database (Denmark)

    Faust, Sebastian; Hazay, Carmit; Nielsen, Jesper Buus

    2012-01-01

    of the secret key. As a second contribution, we construct a signature scheme that achieves security for random messages assuming that the adversary is given a polynomial-time hard to invert function. Here, polynomial-hardness is required even when given the entire public-key – so called weak auxiliary input......-theoretically reveal the entire secret key. In this work, we propose the first constructions of digital signature schemes that are secure in the auxiliary input model. Our main contribution is a digital signature scheme that is secure against chosen message attacks when given an exponentially hard-to-invert function...... security. We show that such signature schemes readily give us auxiliary input secure identification schemes...

  6. Correspondence of vacuum ultraviolet aurora image with the inverted-V structure observed by Kyokko

    International Nuclear Information System (INIS)

    Kaneda, Eisuke; Mukai, Toshifumi; Hirao, Kunio.

    1982-01-01

    Since the Kyokko has been in an orbit with the inclination of 65.3 degree, various patterns of the inverted-V structure can be observed. Correspondence of vacuum ultraviolet aurora image with the inverted-V structure was studied. The energy-time diagrams were obtained. The inverted-V event occurrence map was made. The down-dusk asymmetry was recognized. The patterns of the inverted-V structure observed at present were not much different from previous ones. The observed aurora images showed not only the patterns of aurora, but also the state of aurora spreading in the polar region. Some of the observed results of energy characteristics and the aurora images are shown. (Kato, T.)

  7. Common-Ground-Type Transformerless Inverters for Single-Phase Solar Photovoltaic Systems

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2018-01-01

    This paper proposes a family of novel flying capacitor transformerless inverters for single-phase photovoltaic (PV) systems. Each of the new topologies proposed is based on a flying capacitor principle and requires only four power switches and/or diodes, one capacitor, and a small filter at the o......This paper proposes a family of novel flying capacitor transformerless inverters for single-phase photovoltaic (PV) systems. Each of the new topologies proposed is based on a flying capacitor principle and requires only four power switches and/or diodes, one capacitor, and a small filter...... at the output stage. A simple unipolar sinusoidal pulse width modulation technique is used to modulate the inverter to minimize the switching loss, output current ripple, and the filter requirements. In general, the main advantages of the new inverter topologies are: 1) the negative polarity of the PV...... description of the operating principle with modulation techniques, design guidelines, and comprehensive comparisons is presented to reveal the properties and limitations of each topology in detail. Finally, experimental results of 1-kVA prototypes are presented to prove the concept and theoretical analysis...

  8. Fast Self-Synchronization between LowVoltage Microgrid and Inverter using Virtual Synchronous Converter

    Directory of Open Access Journals (Sweden)

    Md Ruhul Amin

    2017-12-01

    Full Text Available In this paper, a fast self-synchronization known as virtual synchronous converter (VSCon between single-phase microgrid and inverter in low-voltage microgrid, has been developed in Matlab/Simulink. The idea is to any phase locked loop (PLL circuit for inverter-microgrid synchronization in order to improve the synchronization time. As known, it is difficult and lengthy process to tune the PLL gain parameters to reach suitable performance for synchronizing among the voltage, phase-angle and frequency between them. Due to this problem, a fast self synchronization technique is needed in order to minimize the time losses at the microgrid connection. Therefore, the VSCon has been developed which is based on the synchronous generator mathematical model but in virtual environment representation. It has been applied in the inverter control for generating switching pattern to the inverter switches in order to respond to the grid voltage for improve the synchronization. For a prove of concept, several simulation tests in MATLAB models have been conducted, in order to see the effectiveness of this VSCon. First test has been conducted, when a 240V, 50Hz frequency grid source is used for observing the self-synchronization the system with the power flows output. Furthermore, the next test is conducted when the grid frequency is changed from the rated frequency at 50Hz to 51Hz and the result shows the VSCon in inverter control takes nearly 40ms to synchronize to this new frequency value. The test on grid phase-angle delay also been tested when ac grid voltage has 150 phase delay. As from all the results, the improved inverter control with VSCon structure is able to have fast and self-synchronized between the invertergrid connection before the power from the inverter can be transferred.

  9. Control strategy based on SPWM switching patterns for grid connected photovoltaic inverter

    Science.gov (United States)

    Hassaine, L.; Mraoui, A.

    2017-02-01

    Generally, for lower installation of photovoltaic systems connected to the grid, pulse width modulation (PWM) is a widely used technique for controlling the voltage source inverters injects currents into the grid. The current injected must be sinusoidal with reduced harmonic distortion. In this paper, a digital implementation of a control strategy based on PWM switching patterns for an inverter for photovoltaic system connected to the grid is presented. This strategy synchronize a sinusoidal inverter output current with a grid voltage The digital implementation of the proposed PWM switching pattern when is compared with the conventional one exhibit the advantage: Simplicity, reduction of the memory requirements and power calculation for the control

  10. Speed control of an induction motor by 6-switched 3-level inverter

    Directory of Open Access Journals (Sweden)

    Saygin Ali

    2017-12-01

    Full Text Available This paper presents speed control analysis of an induction motor by a 6-switched 3-level inverter. In the analysis of topology, the study used the field oriented control technique which is widely used in the literature, easy and stable for operating systems. The field weaking technique was used for speeds exceeding nominal speed to reduce magnetic saturation and thermal losses. At the end of the process, it was observed to increase motor torque and inverter efficiency. Instead of using 12 switches in conventional 3-level inverters, 6 switches are used in this topology. Reduced number of switches is the greatest contribution of this study.

  11. Study on unitized inverter with photovoltaic grid-connected and stand-alone functions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haining; Su, Jianhui; Ding, Ming [Hefei University of Technology, Hefei (China)

    2008-07-01

    The main circuit and algorithm of unitized single phase inverter are presented, in which photovoltaic (PV) grid-connected algorithm, independency sine inverter algorithm and storage battery charge administer are all integrated basing on DSP (Digital Signal Processor). The control system identifies utility failure initiatively and then switches to independency power supply automatically. The methods of charging battery are multiform. Basing on material term to use utility or solar array to charge can optimize charge efficiency, assure the capacitance of battery and prolong life-span of battery. In addition, some results are offered basing on the prototype of a 2.5kW single phase inverter. (orig.)

  12. Speed control of an induction motor by 6-switched 3-level inverter

    Science.gov (United States)

    Saygin, Ali; Kerem, Alper

    2017-12-01

    This paper presents speed control analysis of an induction motor by a 6-switched 3-level inverter. In the analysis of topology, the study used the field oriented control technique which is widely used in the literature, easy and stable for operating systems. The field weaking technique was used for speeds exceeding nominal speed to reduce magnetic saturation and thermal losses. At the end of the process, it was observed to increase motor torque and inverter efficiency. Instead of using 12 switches in conventional 3-level inverters, 6 switches are used in this topology. Reduced number of switches is the greatest contribution of this study.

  13. Invert emulsion: Method of preparation and application as proper formulation of entomopathogenic fungi.

    Science.gov (United States)

    Batta, Yacoub A

    2016-01-01

    The present article describes the technique used for preparing the invert emulsion (water-in-oil type) then, selecting the most proper formulation of invert emulsion for being used as a carrier formulation of entomopathogenic fungi. It also describes the method used for testing the efficacy of the formulated fungi as biocontrol agents of targeted insects. Detailed examples demonstrating the efficacy of formulated strains of entomopathogenic fungi against certain species of insect pests were included in the present article. The techniques and methods described in this article are reproducible and helpful in enhancing the effectiveness of formulated fungi against wide range of targeted insects in comparison with the unformulated form of these fungi. Also, these techniques and methods can be used effectively in crop protection and in the integrated pest management programs. Finally, it is important to indicate that the ingredients used for preparation of the invert emulsion have no environmental side-effects or health risks since these ingredients are safe to use and can be used in manufacturing of cosmetics or as food additives.•Description of method used for preparation of invert emulsion (water-in-oil type) and selecting the most stable and non-viscous emulsion.•Description of technique used for introducing the entomopathogenic fungi into the selected stable and non-viscous invert emulsion.•Description of method for testing the efficacy of introduced entomopathogenic fungus into the selected invert emulsion against targeted insects with detailed examples on the efficacy testing.

  14. Co-design of the LCL Filter and Control for Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Zhang, Yu; Xue, Mingyu; Li, Minying

    2014-01-01

    In most grid-connected inverters (GCI) with an LCL filter, since the design of both the LCL filter and the controller is done separately, considerable tuning efforts have to be exerted when compared to inverters using an L filter. Consequently, an integrated co-design of the filter and the contro...

  15. Adaptive Droop Control Applied to Distributed Generation Inverters Connected to the Grid

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Vásquez, Juan C.

    2008-01-01

    This paper proposes a novel control for voltage source inverters connected to the grid. The control scheme is based on the droop method, and it uses some estimated variables from the grid such as the voltage and the frequency, and the magnitude and angle of the grid impedance. Hence, the inverter...

  16. Comparison between symmetrical and asymmetrical single phase multilevel inverter with diode-clamped topology

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Nami, A.; Zare, F.

    2008-01-01

    In this paper, a different configuration based on different DC bus voltage for a diode-clamped multilevel inverter has been presented. Two different symmetrical and asymmetrical arrangements of a four-level diode clamped inverters have been compared, in order to find an optimum arrangement...... compared with the conventional four-level inverter and this will lead to the reduction of harmonic content of output voltage. A predictive current control technique has been carried out to verify the viability of new configuration. The advantages of this control method are simplicity and applicability...

  17. Mission profile based multi-disciplinary analysis of power modules in single-phase transformerless photovoltaic inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2013-01-01

    years) has been set as a main target and an emerging demand from the customers, which imposes a new challenge on grid-connected transformerless inverters. In order to reduce maintenance cost, it is essential to predict the lifetime of the transformerless PV inverter and its components based......The popularity of transformerless photovoltaic (PV) inverters in Europe proves that these topologies can achieve higher efficiency (e.g., ≥ 98% has been reported). Along with the advanced power electronics technology and the booming development of PV power systems, a long service time (e.g. 25...... on the mission profiles — solar irradiance and ambient temperature. In this paper, a mission profile based analysis approach is proposed and it is demonstrated by three main single-phase transformerless PV inverters — Full-Bridge (FB) with bipolar modulation scheme, the FB inverter with DC bypass (FB...

  18. Non-Inverting Buck-Boost Converter for Fuel Cell Applications

    DEFF Research Database (Denmark)

    Schaltz, Erik; Rasmussen, Peter Omand; Khaligh, Alireza

    2008-01-01

    Fuel cell DC/DC converters often have to be able to both step-up and step-down the input voltage, and provide a high efficiency in the whole range of output power. Conventional negative output buck-boost and non-inverting buck-boost converters provide both step-up and step-down characteristics....... In this paper the non-inverting buck-boost with either diodes or synchronous rectifiers is investigated for fuel cell applications. Most of previous research does not consider  the parasitic in the evaluation of the converters. In this study, detailed analytical expressions of the efficiencies for the system...

  19. Voltage-spike analysis for a free-running parallel inverter

    Science.gov (United States)

    Lee, F. C. Y.; Wilson, T. G.

    1974-01-01

    Unwanted and sometimes damaging high-amplitude voltage spikes occur during each half cycle in many transistor saturable-core inverters at the moment when the core saturates and the transistors switch. The analysis shows that spikes are an intrinsic characteristic of certain types of inverters even with negligible leakage inductance and purely resistive load. The small but unavoidable after-saturation inductance of the saturable-core transformer plays an essential role in creating these undesired thigh-voltage spikes. State-plane analysis provides insight into the complex interaction between core and transistors, and shows the circuit parameters upon which the magnitude of these spikes depends.

  20. Nonlinear analysis of a family of LC tuned inverters. [dc to square wave circuits for power conditioning

    Science.gov (United States)

    Lee, F. C. Y.; Wilson, T. G.

    1974-01-01

    A family of four dc-to-square-wave LC tuned inverters are analyzed using singular point. Limit cycles and waveshape characteristics are given for three modes of oscillation: quasi-harmonic, relaxation, and discontinuous. An inverter in which the avalanche breakdown of the transistor emitter-to-base junction occurs is discussed and the starting characteristics of this family of inverters are presented. The LC tuned inverters are shown to belong to a family of inverters with a common equivalent circuit consisting of only three 'series' elements: a five-segment piecewise-linear current-controlled resistor, linear inductor, and linear capacitor.

  1. Integrated Inverter And Battery Charger

    Science.gov (United States)

    Rippel, Wally E.

    1988-01-01

    Circuit combines functions of dc-to-ac inversion (for driving ac motor in battery-powered vehicle) and ac-to-dc conversion (for charging battery from ac line when vehicle not in use). Automatically adapts to either mode. Design of integrated inverter/charger eliminates need for duplicate components, saves space, reduces weight and cost of vehicle. Advantages in other applications : load-leveling systems, standby ac power systems, and uninterruptible power supplies.

  2. Effective switching frequency multiplier inverter

    Science.gov (United States)

    Su, Gui-Jia [Oak Ridge, TN; Peng, Fang Z [Okemos, MI

    2007-08-07

    A switching frequency multiplier inverter for low inductance machines that uses parallel connection of switches and each switch is independently controlled according to a pulse width modulation scheme. The effective switching frequency is multiplied by the number of switches connected in parallel while each individual switch operates within its limit of switching frequency. This technique can also be used for other power converters such as DC/DC, AC/DC converters.

  3. Rapid islanding detection using multi-level inverter for grid-interactive PV system

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2014-01-01

    Graphical abstract: - Highlights: • Novel reference signal is used to form an islanding detection scheme for PV system. • Supply fixed magnitude sinusoidal signal even if utility grid is disconnected. • Seamless transfer between grid-connected and stand-alone modes is possible. - Abstract: A novel reference signal generator is combined with a multi-level inverter to form a rapid islanding detection scheme for grid-interactive PV system. The reference signal generator can easily be synchronized with the utility grid signal and produced a fixed magnitude and very low total harmonic distortion (THD) sinusoidal signal which is in phase with the utility grid signal. Unlike conventional phase-locked loop (PLL) circuitry, the reference signal generator can also provide a fixed magnitude sinusoidal signal even if the utility grid is disconnected and automatically re-synchronous with the grid rapidly. Consequently, seamless transfer between grid-connected and stand-alone modes could easily be achieved if anti-islanding protection is not required. If a saturation element is applied to the raw reference signal followed by the synthesis of the truncated signal using a multi-level inverter, the distinct flat-top feature of the synthesized signal can quickly and easily be identified if the network is in islanding mode at the point of common coupling. Experimental results are included to demonstrate the effectiveness of the proposed detection scheme

  4. Controlling An Inverter-Driven Three-Phase Motor

    Science.gov (United States)

    Dolland, C.

    1984-01-01

    Control system for three-phase permanent-magnet motor driven by linecommutated inverter uses signals generated by integrating back emf of each phase of motor. High-pass filter network eliminates low-frequency components from control loop while maintaining desired power factor.

  5. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  6. Lifetime Evaluation of Grid-Connected PV Inverters Considering Panel Degradation Rates and Installation Sites

    OpenAIRE

    Sangwongwanich, Ariya; Yang, Yongheng; Sera, Dezso; Blaabjerg, Frede

    2018-01-01

    Lifetime of PV inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels, and thus long-term energy production and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper thus evaluates the lifetime of PV inverters considering panel degrada...

  7. Advances in PV Inverters

    DEFF Research Database (Denmark)

    Anthon, Alexander

    and preferably low complexity leads to new research demands. This is especially true in the field of low cost residential PV inverters where efficiencies are used as major selling arguments. Traditional converter topologies equipped with conventional Silicon based semiconductors to date reach their limitations......, a replacement of only two switching devices per phase leg can greatly reduce the semiconductor losses. The Hybrid-NPC converter can be seen as an attractive and cost competitive alternative to the Silicon Carbide based converter, also allowing to overcome the major drawbacks with the conventional Silicon IGBT...

  8. The Internet and the Inverted Classroom.

    Science.gov (United States)

    Lage, Maureen J.; Platt, Glenn

    2000-01-01

    Describes a Web site that is for an undergraduate principles of microeconomics course and a main component of "The Inverted Classroom" in which lectures take place outside of class. Explains that the Web site is divided into four sections: (1) the classroom; (2) the desk; (3) the coffee shop; and (4) the library. (CMK)

  9. Effects of silicon carbide MOSFETs on the efficiency and power quality of a microgrid-connected inverter

    International Nuclear Information System (INIS)

    Ding, Xiaofeng; Chen, Feida; Du, Min; Guo, Hong; Ren, Suping

    2017-01-01

    Highlights: •The characteristics comparison between SiC-inverter and Si-inverter is implemented, considering thermal effects. •The voltage distortion of inverters is modeling from the perspective of the behaviors of the device. •The efficiency of the microgrid-connected inverter has been greatly increased by replacing Si with SiC. •The SiC microgrid-connected inverter has smaller voltage distortion and less harmonic current than those of Si-inverter. •The proposed analytical model has been validated by the experimental test. -- Abstract: With the expanding power demands and increasing use of renewable energy resources, microgrids have been widely supported. Wide bandgap semiconductor devices with higher blocking voltage capabilities and higher switching speeds, such as silicon carbide (SiC) devices, will become a critical component in building microgrids. This paper describes a comprehensive investigation of the effects of SiC Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) on the efficiency and power quality of the inverters used in low voltage microgrids compared with conventional inverters based on silicon (Si) Insulated-gate Bipolar Transistors (IGBTs). First, the characteristics of both SiC and Si are measured by a double pulse test (DPT), considering thermal effects. Then, conduction and switching losses under different temperatures are calculated based on DPT results. Second, phase voltage distortions are modeled and calculated according to the tested switching and conduction characteristics of SiC, resulting in harmonic components in the phase current. Finally, an experiment is implemented. The experimental results show that the SiC-inverter greatly increases the energy efficiency and improves the power quality in the microgrid; these results are consistent with the analytical results.

  10. INVERTING ORTHOTOPIC ILEOCYSTOPLASTY FOR SHORT MESENTERY

    Directory of Open Access Journals (Sweden)

    V. A. Perepechay

    2010-01-01

    Full Text Available During orthotopic ileocystoplasty, the short mesentery causes an increase in the risk of incompetence of anastomosis of the reservoir with the urethra. Inverting orthotopic ileocystoplasty ensures a free reservoir pull-through into the small pelvis and eliminates tissue tension in the anastomosis. The proposed procedure differs from the Studer operation in that the reservoir is sutured lengthwise, after which it is inverted between the mesenteric leaves. The posterior reservoir wall is anteverted and freely brought out into the small pelvis. This reduces the distance to the urethral stump by 3-4 cm. This procedure was used in 19 patients to be operated on. There were no cases of reservoir or reservoir-urethral anastomotic incompetence. The mean neocystic capacity was 110, 350, and 490 ml 0, 3, and 12 months, respectively, after urethral catheter removal. The maximum reservoir pressure does not exceed 40 (mean 30 cm H2O. Daytime urinary retention was 94.7%; nocturnal urinary retention during forced nocturnal miction was 79%. The obtained functional results compare well with those achieved during the similar procedures.

  11. INVERTING ORTHOTOPIC ILEOCYSTOPLASTY FOR SHORT MESENTERY

    Directory of Open Access Journals (Sweden)

    V. A. Perepechay

    2014-07-01

    Full Text Available During orthotopic ileocystoplasty, the short mesentery causes an increase in the risk of incompetence of anastomosis of the reservoir with the urethra. Inverting orthotopic ileocystoplasty ensures a free reservoir pull-through into the small pelvis and eliminates tissue tension in the anastomosis. The proposed procedure differs from the Studer operation in that the reservoir is sutured lengthwise, after which it is inverted between the mesenteric leaves. The posterior reservoir wall is anteverted and freely brought out into the small pelvis. This reduces the distance to the urethral stump by 3-4 cm. This procedure was used in 19 patients to be operated on. There were no cases of reservoir or reservoir-urethral anastomotic incompetence. The mean neocystic capacity was 110, 350, and 490 ml 0, 3, and 12 months, respectively, after urethral catheter removal. The maximum reservoir pressure does not exceed 40 (mean 30 cm H2O. Daytime urinary retention was 94.7%; nocturnal urinary retention during forced nocturnal miction was 79%. The obtained functional results compare well with those achieved during the similar procedures.

  12. Reliability Oriented Design Tool For the New Generation of Grid Connected PV-Inverters

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian; Blaabjerg, Frede; Wang, Huai

    2015-01-01

    is achieved and is further used as an input to the lifetime model. The proposed reliability-oriented design tool is used to study the impact of mission profile (MP) variation and device degradation (aging) in the PV inverter lifetime. The obtained results indicate that the MP of the field where the PV...... inverter is operating has an important impact (up to 70%) on the converter lifetime expectation, and it should be considered in the design stage to better optimize the converter design margin. In order to have correct lifetime estimation, it is crucial to consider also the device degradation feedback (in......This paper introduces a reliability-oriented design tool for a new generation of grid-connected photovoltaic (PV) inverters. The proposed design tool consists of a real field mission profile (RFMP) model (for two operating regions: USA and Denmark), a PV panel model, a grid-connected PV inverter...

  13. Highly Reliable Transformerless Photovoltaic Inverters With Leakage Current and Pulsating Power Elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Loh, Poh Chiang

    2016-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common-mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Furthermore, the proposed inverter can also eliminate the well-known double-line-frequency pulsating...... power that is inherent in single-phase PV systems. By properly injecting CM voltages to the output filter capacitors, the pulsating power can be decoupled from the dc-link. Therefore, it is possible to use long-lifetime film capacitors instead of electrolytic capacitors to improve the reliability...

  14. Fault diagnosis method based on FFT-RPCA-SVM for Cascaded-Multilevel Inverter.

    Science.gov (United States)

    Wang, Tianzhen; Qi, Jie; Xu, Hao; Wang, Yide; Liu, Lei; Gao, Diju

    2016-01-01

    Thanks to reduced switch stress, high quality of load wave, easy packaging and good extensibility, the cascaded H-bridge multilevel inverter is widely used in wind power system. To guarantee stable operation of system, a new fault diagnosis method, based on Fast Fourier Transform (FFT), Relative Principle Component Analysis (RPCA) and Support Vector Machine (SVM), is proposed for H-bridge multilevel inverter. To avoid the influence of load variation on fault diagnosis, the output voltages of the inverter is chosen as the fault characteristic signals. To shorten the time of diagnosis and improve the diagnostic accuracy, the main features of the fault characteristic signals are extracted by FFT. To further reduce the training time of SVM, the feature vector is reduced based on RPCA that can get a lower dimensional feature space. The fault classifier is constructed via SVM. An experimental prototype of the inverter is built to test the proposed method. Compared to other fault diagnosis methods, the experimental results demonstrate the high accuracy and efficiency of the proposed method. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Performance Evaluation of Three Different Inverter Configurations of DVR for Mitigation of Voltage Events

    Directory of Open Access Journals (Sweden)

    Miska Prasad

    2016-12-01

    Full Text Available The voltage events namely voltage sags and voltage swells represent the most common, frequent and important power quality events in today’s power system. Dynamic voltage restorer (DVR is one of the key components used to mitigate the supply voltage quality disturbances in terms of voltage sags and swells in the distribution system. It consists of an energy storage unit, a voltage source inverter, a filter, a coupling transformer and the control system. This paper presents three different inverter configurations of dynamic voltage restorer (DVR for mitigation of voltage events such as voltage sags and swells with sudden addition or removal of the nonlinear load. These three configurations are voltage source inverter based DVR (VSI-DVR, current source inverter based DVR (CSI-DVR and impedance or Z-source inverter based DVR (ZSI-DVR. The d-q control technique is used to control the operation of the DVR. The response of ZSI-DVR for mitigation of voltage sags and swells are investigated and compared with VSI-DVR and CSI-DVR using MATLAB/SIMULINK environment.

  16. Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Austin; Martin, Gregory; Hurtt, James

    2017-05-08

    As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 with Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and volt-age/frequency ride-through, among others. A comparative experimental evaluation has been completed on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and the effect on abnormal grid condition response. This study examines the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. This report reviews comparative test data, which shows that GSFs have little impact on the metrics of interest in most tests cases.

  17. CRADA Final Report for CRADA Number ORNL98-0521 : Development of an Electric Bus Inverter Based on ORNL Auxiliary Resonant Tank (ART) Soft-Switching Technology; TOPICAL

    International Nuclear Information System (INIS)

    Ayers, C.W.

    2001-01-01

    The Power Electronics and Electric Machinery Research Center (PEEMRC) of Oak Ridge National Laboratory (ORNL) has for many years been developing technologies for power converters for motor drives and many other applications. Some of the research goals are to improve efficiency and reduce audible and electromagnetic interference noise generation for inverters and the driven loads. The converters are being required to produce more power with reduced weight and volume, which requires improvements in heat removal from the electronics, as well as improved circuit designs that have fewer electrical losses. PEEMRC has recently developed and patented a soft-switching inverter topology called an Auxiliary Resonant Tank (ART), and this design has been tested and proven at ORNL using a 10-kW laboratory prototype. The objective of this project was to develop, test, and install the ART inverter technology in an electric transit bus with the final goal of evaluating performance of the ORNL inverter under field conditions in a vehicle. A scaled-up inverter with the capacity to drive a 22-e bus was built based on the 10-kW ORNL laboratory prototype ART soft-switching inverter. Most (if not all) commercially available inverters for traction drive and other applications use hard-switching inverters. A Cooperative Research and Development Agreement was established with the Chattanooga Area Regional Transit Authority (CARTA), the Electric Transit Vehicle Institute (ETVI), and Advanced Vehicle Systems (AVS), all of Chattanooga, along with ORNL. CARTA, which maintains and operates the public transit system in Chattanooga, provided an area for testing the vehicle alongside other similar vehicles in the normal operating environment. ETVI offers capabilities in standardized testing and reporting and also provides exposure in the electric transit vehicle arena for ORNL's technologies. The third Chattanooga partner, (AVS) manufactures all-electric and hybrid electric transit buses using

  18. Leakage current analysis of single-phase transformer-less grid-connected PV inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Kerekes, Tamas; Teodorescu, Remus

    2016-01-01

    Transformer-less string PV inverter is getting more and more widely utilized due to its higher efficiency, smaller volume and weight. However, without the galvanic isolation, the leakage current limitation and operation safety became the key issues of transformer-less inverters. This paper...... simplifies the leakage current generation circuit model and presents a leakage current estimation method both in real time and frequency domain. It shows that the leakage current is related to the circuit stray parameters, output filter and common mode voltage. Furthermore, with the proposed analysis method......, the leakage current generation of H-bridge with different modulation methods and HERIC inverter are discussed individually. At last, the presented method has been verified via simulation....

  19. Performance Evaluation of Three-Level Z-Source Inverters Under Semiconductor-Failure Conditions

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2009-01-01

    This paper evaluates and proposes various compensation methods for three-level Z-source inverters under semiconductor-failure conditions. Unlike the fault-tolerant techniques used in traditional three-level inverters, where either an extra phase-leg or collective switching states are used......, the proposed methods for three-level Z-source inverters simply reconfigure their relevant gating signals so as to ride-through the failed semiconductor conditions smoothly without any significant decrease in their ac-output quality and amplitude. These features are partly attributed to the inherent boost...... under semiconductor-failure conditions. For verifying these described performance features, PLECS simulation and experimental testing were performed with some results captured and shown in a later section for visual confirmation....

  20. Ultra-low-loss inverted taper coupler for silicon-on-insulator ridge waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Liu, Liu; Ou, Haiyan

    2010-01-01

    An ultra-low-loss coupler for interfacing a silicon-on-insulator ridge waveguide and a single-mode fiber in both polarizations is presented. The inverted taper coupler, embedded in a polymer waveguide, is optimized for both the transverse-magnetic and transverse-electric modes through tapering...... the width of the silicon-on-insulator waveguide from 450 nm down to less than 15 nm applying a thermal oxidation process. Two inverted taper couplers are integrated with a 3-mm long silicon-on-insulator ridge waveguide in the fabricated sample. The measured coupling losses of the inverted taper coupler...... for transverse-magnetic and transverse-electric modes are ~0.36 dB and ~0.66 dB per connection, respectively....

  1. Electronic inverter assembly

    Science.gov (United States)

    Singh, Brij N.; Schmit, Christopher J.

    2018-05-22

    A first driver portion comprises a set of first components mounted on or associated with a first circuit board. A second circuit board is spaced apart from the first circuit board. A second driver portion comprises a set of second components mounted on or associated with the second circuit board, where the first driver portion and the second driver portion collectively are adapted to provide input signals to the control terminal of each semiconductor switch of an inverter. A first edge connector is mounted on the first circuit board. A second edge connector is mounted on the second circuit board. An interface board has mating edges that mate with the first edge connector and the second edge connector.

  2. Smart Inverters for Utility and Industry Applications

    DEFF Research Database (Denmark)

    Xue, Yaosuo; Guerrero, Josep M.

    2015-01-01

    Smart inverters are emerging with increasing renewable energy and smart grid development. While the recent work reviewed mostly focuses on defining standardized control functionalities and smart grid communication protocols, we take a holistic approach in this paper and propose a holon-type smart...

  3. Control Architecture for Parallel-Connected Inverters in Uninterruptible Power Systems

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    bus. The proposed control scheme comprises two layers: (i) a local layer that contains a “reactive power-to-phase droop” in order to synchronize the phase angle of each inverter and a virtual resistance loop that guarantees equal power sharing among inverters; and (ii) a central controller...... that guarantees synchronization with an external real/fictitious utility, and critical bus voltage amplitude restoration. Improved transient and steady-state frequency, active, reactive and harmonic power sharing, and global phase-locked loop resynchronization capability are achieved. Detailed system topology...

  4. Harmonic resonance assessment of multiple paralleled grid-connected inverters system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper presents an eigenvalue-based impedance stability analytical method of multiple paralleled grid-connected inverter system. Different from the conventional impedance-based stability criterion, this work first built the state-space model of paralleled grid-connected inverters. On the basis...... of this, a bridge between the state-space-based modelling and impedance-based stability criterion is presented. The proposed method is able to perform stability assessment locally at the connection points of the component. Meanwhile, the eigenvalue-based sensitivity analysis is adopted to identify...

  5. The CMOS integration of a power inverter

    Science.gov (United States)

    Mannarino, Eric Francis

    Due to their falling costs, the use of renewable energy systems is expanding around the world. These systems require the conversion of DC power into grid-synchronous AC power. Currently, the inverters that carry out this task are built using discrete transistors. TowerJazz Semiconductor Corp. has created a commercial CMOS process that allows for blocking voltages of up to 700 V, effectively removing the barrier to integrating power inverters onto a single chip. This thesis explores this process using two topologies. The first is a cell-based switched-capacitor topology first presented by Ke Zou. The second is a novel topology that explores the advantage of using a bused input-output system, as in digital electronics. Simulations run on both topologies confirm the high-efficiency demonstrated in Zou’s process as well as the advantage the bus-based system has in output voltage levels.

  6. Advanced Control of Wheeled Inverted Pendulum Systems

    CERN Document Server

    Li, Zhijun; Fan, Liping

    2013-01-01

    Advanced Control of Wheeled Inverted Pendulum Systems is an orderly presentation of recent ideas for overcoming the complications inherent in the control of wheeled inverted pendulum (WIP) systems, in the presence of uncertain dynamics, nonholonomic kinematic constraints as well as underactuated configurations. The text leads the reader in a theoretical exploration of problems in kinematics,dynamics modeling, advanced control design techniques,and trajectory generation for WIPs. An important concern is how to deal with various uncertainties associated with the nominal model, WIPs being characterized by unstable balance and unmodelled dynamics and being subject to time-varying external disturbances for which accurate models are hard to come by.   The book is self-contained, supplying the reader with everything from mathematical preliminaries and the basic Lagrange-Euler-based derivation of dynamics equations to various advanced motion control and force control approaches as well as trajectory generation met...

  7. An Inverted Curriculum for CS1

    DEFF Research Database (Denmark)

    Caspersen, Michael Edelgaard

    2003-01-01

    present and discuss the inverted curriculum for our introductory object-oriented programming course, and our experiences from teaching this course for four years. We identify four levels for the systematic construction of programs, and the structure of our programming course is based on these four levels......: the modeling level, the design level, the class level, and the algorithmic level....

  8. Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation

    Directory of Open Access Journals (Sweden)

    Meenakshi Jayaraman

    2017-11-01

    Full Text Available Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse width modulated five-level cascaded inverter interfaced grid connected system. The proposed passive filter inserts an additional resistance-capacitance branch in parallel to the filter capacitor of the traditional inductive–capacitive–inductive filter in addition to a resistance in series with it to reduce damping power loss. It can attenuate the switching frequency harmonic current components much better than the traditional filter while maintaining the same overall inductance, reduced capacitance and resistance values. The basic parameter design procedure and an approach to discover the parameters of the proposed filter is introduced. Further, a novel methodology using Particle Swarm Optimization (PSO is recommended to guarantee minimum damping loss while ensuring reduced peak during resonance. In addition, PSO algorithm is newly employed in this work to maximize harmonic attenuation in and around the switching frequency on the premise of allowable values of filter inductance and capacitance. A comparative discussion considering traditional passive filters and the proposed filter is presented and evaluated through experiments conducted on a 110 V, 1 kW five-level grid connected inverter. The modulation algorithm for the multilevel inverter is implemented using a SPARTAN 6-XC6SLX25 Field Programmable Gate Array (FPGA processor. The analysis shows that the proposed filter not only provides decreased damping power loss but also is capable of providing considerable harmonic ripple reduction in the high frequency band, improved output waveforms and lesser

  9. Lower-Temperature Invert Design For Diffusion Barrier

    International Nuclear Information System (INIS)

    Bruce Stanley

    2001-01-01

    The objective of this analysis is to advance the state of the subsurface facilities design to primarily support the ''Yucca Mountain Science and Engineering Report'' (DOE 2001) and to also support the preparation and revision of System Description Document's Section 2 system descriptions (CRWMS M and O 2001, pp. 9 and 11). The results may also eventually support the License Application (CRWMS M and O 2001, p. 3). The Performance Assessment Department will be the primary user of the information generated and will be used in abstraction modeling for the lower-temperature scenario (CRWMS M and O 200 1, p. 27). This analysis will evaluate the invert relative to the lower- and higher-temperature conditions in accordance with the primary tasks below. Invert design is a major factor in allowing water entering the drift to pass freely and enter the drift floor without surface ponding and in limiting diffusive transport into the host rock. Specific cost effective designs will be conceptualized under the new lower-temperature conditions in this analysis. Interfacing activities and all aspects of Integrated Safety Management and Nuclear Culture principles are included in this work scope by adhering to the respective principles during this design activity and by incorporating safety into the design analysis (CRWMS M and O 2001, p. 8). Primary tasks of this analysis include identifying available design information from existing sources on the invert as a diffusive barrier, developing concepts that reduce the amount steel, and developing other design features that accommodate both lower- and higher-temperature operating modes (CRWMS M and O 2001, p.16)

  10. Topological Design and Modulation Strategy for Buck-Boost Three-Level Inverters

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Teodorescu, Remus

    2009-01-01

    To date, designed topologies for dc-ac inversion with both voltage buck and boost capabilities are mainly focused on two-level circuitries with extensions to three-level possibilities left nearly unexplored. Contributing to this area of research, this paper presents the design of a number of viable...... can perform distinct five-level line voltage and three-level phase voltage switching by simply controlling the active switches located in the designed voltage boost section of the circuits. As a cost saving option, one active switch can further be removed from the voltage boost section of the circuits...... buck-boost threelevel inverters that can also support bidirectional power conversion. The proposed front-end circuitry is developed from the C´ ukderived buck-boost two-level inverter, and by using the "alternative phase opposition disposition" modulation scheme, the buck-boost three-level inverters...

  11. A Modified Droop Control Method for Parallel-Connected Current Source Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    In this paper, a novel control method was proposed for current source inverters under the grid-connected working mode. The control scheme is based on a modified droop control method, with an additional current reference signal that will be generated instead of the voltage reference. Hence......, there is only a current control loop with droop control in the whole control scheme without voltage control loop. So it is very suitable for grid-connected current source inverter which will simplify the design of the control scheme and combine the advantage of droop control. The parallel configuration...... is widely used to acquire high power demand, but the circulating current problem is a key issue that should be considered. In this paper, a simulation based on parallel current source inverters using the proposed control scheme is provided. Simulation results showed that a good circulating current...

  12. Restoration of Low-Voltage Distribution Systems with Inverter-Interfaced DG Units

    DEFF Research Database (Denmark)

    Dietmannsberger, Markus; Wang, Xiongfei; Blaabjerg, Frede

    2018-01-01

    -area voltage collapse. This paper proposes a restoration strategy from zero voltage conditions for inverter-interfaced DG under islanded conditions. In the approach, a flexible and scalable Master DG inverter concept is introduced for distributed generations, where no communication is needed and an outage......The increasing share of distributed generation (DG) offers new chances in grid restoration of low-voltage distribution grids. Instead of relying on the transmission or high- and medium-voltage levels, establishing islanding operation in low-voltage grids might be a good option after a wide...... of the Master can be balanced by other DG inverters. The control strategy ensures the tracking of nominal values of the system voltage and frequency without zero steady-state error. The influences of non-controllable DG are also taken into account in the strategy with an effective countermeasure developed...

  13. Transformer-based asymmetrical embedded Z-source neutral point clamped inverters with continuous input current and enhanced voltage boost capability

    DEFF Research Database (Denmark)

    Mo, W.; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current. This paper proposes six types transformer-based impedance-so......-source NPC inverters which have enhanced voltage boost capability and continuous input current by utilizing of transformer and embedded dc source configuration. Experimental results are presented to verify the theory validation....

  14. Modeling the frequency response of photovoltaic inverters

    NARCIS (Netherlands)

    Ernauli Christine Aprilia, A.; Cuk, V.; Cobben, J.F.G.; Ribeiro, P.F.; Kling, W.L.

    2012-01-01

    The increased presence of photovoltaic (PV) systems inevitably affects the power quality in the grid. This new reality demands grid power quality studies involving PV inverters. This paper proposes several frequency response models in the form of equivalent circuits. Models are based on laboratory

  15. Regenerative Snubber For GTO-Commutated SCR Inverter

    Science.gov (United States)

    Rippel, Wally E.; Edwards, Dean B.

    1992-01-01

    Proposed regenerative snubbing circuit substituted for dissipative snubbing circuit in inverter based on silicon controlled rectifiers (SCR's) commutated by gate-turn-off thyristor (GTO). Intended to reduce loss of power that occurs in dissipative snubber. Principal criteria in design: low cost, simplicity, and reliability.

  16. Alpha detection in pipes using an inverting membrane scintillator

    International Nuclear Information System (INIS)

    Kendrick, D.T.; Cremer, C.D.; Lowry, W.; Cramer, E.

    1995-01-01

    Characterization of surface alpha emitting contamination inside enclosed spaces such as piping systems presents an interesting radiological measurement challenge. Detection of these alpha particles from the exterior of the pipe is impossible since the alpha particles are completely absorbed by the pipe wall. Traditional survey techniques, using hand-held instruments, simply can not be used effectively inside pipes. Science and Engineering Associates, Inc. is currently developing an enhancement to its Pipe Explorer trademark system that will address this challenge. The Pipe Explorer trademark uses a unique sensor deployment method where an inverted tubular membrane is propagated through complex pipe runs via air pressure. The inversion process causes the membrane to fold out against the pipe wall, such that no part of the membrane drags along the pipe wall. This deployment methodology has been successfully demonstrated at several DOE sites to transport specially designed beta and gamma scintillation detectors into pipes ranging in length up to 250 ft. The measurement methodology under development overcomes the limitations associated with conventional hand-held survey instruments by remotely emplacing an alpha scintillator in direct contact with the interior pipe surface over the entire length to be characterized. This is accomplished by incorporating a suitable scintillator into the otherwise clear membrane material. Alpha particles emitted from the interior pipe surface will intersect the membrane, resulting in the emission of light pulses from the scintillator. A photodetector, towed by the inverting membrane, is used to count these light pulses as a function of distance into the pipe, thereby producing a log of the surface alpha contamination levels. It is anticipated that the resulting system will be able to perform measurements in pipes as small as two inches in diameter, and several hundred feet in length

  17. Design and development of high performance solar photovoltaic inverter with advanced modulation techniques to improve power quality

    Science.gov (United States)

    Alexander Stonier, Albert

    2017-02-01

    In addition to the focus towards growing demand on electrical energy due to the increase in population, industries, consumer loads, etc., the need for improving the quality of electrical power also needs to be considered. The design and development of solar photovoltaic (PV) inverter with reduced harmonic distortions is proposed. Unlike the conventional solar PV inverters, the proposed inverter provides the advantages of reduced harmonic distortions thereby intend towards the improvement in power quality. This inverter comprises of multiple stages which provides the required 230VRMS, 50 Hz in spite of variations in solar PV due to temperature and irradiance. The reduction of harmonics is governed by applying proper switching sequences required for the inverter switches. The detailed analysis is carried out by employing different switching techniques and observing its performance. With a separate mathematical model for a solar PV, simulations are performed in MATLAB software. To show the advantage of the system proposed, a 3 kWp photovoltaic plant coupled with multilevel inverter is demonstrated in hardware. The novelty resides in the design of a single chip controller which can provide the switching sequence based on the requirement and application. As per the results obtained, the solar-fed multistage inverter improves the quality of power which makes this inverter suitable for both stand-alone and grid-connected systems.

  18. The "LIFT" lesion: lateral inverted osteochondral fracture of the talus.

    Science.gov (United States)

    Dunlap, Bradley J; Ferkel, Richard D; Applegate, Gregory R

    2013-11-01

    The purpose of this study was to assess a series of lateral inverted osteochondral fractures of the talus. Over a 17-year period, 10 patients with an acute lateral inverted osteochondral fracture of the talus after an inversion injury to the ankle were identified. Diagnosis was made by physical examination, radiographs, magnetic resonance imaging, and/or computed tomography scan. Arthroscopy was initially performed on all patients. All patients had an inverted osteochondral fragment. In 8 of 10 patients the fragment was reattached in an open manner in conjunction with lateral ligament reefing. The fragment was excised in 2 patients. The mean age of the patients was 17.2 years. They were evaluated with the Single Assessment Numeric Evaluation, American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale, modified Weber score, Berndt and Harty score, and Short Form 36 version 2 score. Physical and radiographic examination was also performed. The mean time to follow-up was 112.3 months (9.3 years). The mean American Orthopaedic Foot and Ankle Society score improved from 18.9 preoperatively to 86.9 postoperatively (P ≤ .0001). The mean Single Assessment Numeric Evaluation and modified Weber scores were 81.6 and 81.5, respectively. On the Berndt and Harty scale, 6 patients had a good to excellent rating; 3, fair; and 1, poor. The mean Short Form 36 version 2 scores corresponded to national averages for healthy populations. Mean loss of motion for dorsiflexion and plantarflexion was 6.8° and 3.0°, respectively, when compared with the contralateral side. All patients showed some osteophyte formation on follow-up radiographs. An inverted osteochondral fracture of the lateral talus (lateral, inverted, fracture, talus [LIFT lesion]) can occur after a twisting injury to the ankle. Clinical suspicion should be high, especially in the younger athlete. This injury can be successfully managed with a combined arthroscopic and open approach. Level IV, therapeutic case

  19. Neutral-point voltage dynamic model of three-level NPC inverter for reactive load

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Munk-Nielsen, Stig; Busquets-Monge, Sergio

    2012-01-01

    A three-level neutral-point-clamped inverter needs a controller for the neutral-point voltage. Typically, the controller design is based on a dynamic model. The dynamic model of the neutral-point voltage depends on the pulse width modulation technique used for the inverter. A pulse width modulati...

  20. Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition

    International Nuclear Information System (INIS)

    Yang Ruichang; Liu Ruolei; Liu Jinggong; Qin Shiwei

    2008-01-01

    In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well with the experimental data. This indicates that the developed mathematical model and solution method can be used to correctly predict the reverse flow in the inverted U-tubes of the steam generator with natural circulation. The obtained results also show that in the analysis of natural circulation flow in the primary circuit, the reverse flow in the inverted U-tubes of the steam generator must be taken into account. (author)