WorldWideScience

Sample records for produced radiotracers 71ge

  1. Penning-trap Q-value determination of the 71Ga(ν,e−)71Ge reaction using threshold charge breeding of on-line produced isotopes

    International Nuclear Information System (INIS)

    Frekers, D.; Simon, M.C.; Andreoiu, C.; Bale, J.C.; Brodeur, M.; Brunner, T.; Chaudhuri, A.; Chowdhury, U.; Crespo López-Urrutia, J.R.; Delheij, P.; Ejiri, H.; Ettenauer, S.; Gallant, A.T.; Gavrin, V.; Grossheim, A.; Harakeh, M.N.; Jang, F.; Kwiatkowski, A.A.

    2013-01-01

    We present a first direct Q-value measurement of the 71 Ga(ν,e − ) 71 Ge reaction using the TITAN mass-measurement facility at ISAC/TRIUMF. The measurements were performed in a Penning trap on neon-like 71 Ga 21+ and 71 Ge 22+ using isobar separation of the on-line produced mother and daughter nuclei through threshold charge breeding in an electron-beam ion trap. In addition, isoionic samples of 71 Ga 21+ and 71 Ge 21+ were stored concurrently in the Penning trap and provided a separate Q-value measurement. Both independent measurements result in a combined Q-value of 233.5±1.2 keV, which is in agreement with the previously accepted Q-value for the ν cross-section calculations. Together with a recent measurement of the ν-response from the excited states in 71 Ge, we conclude that there are no further uncertainties in the nuclear structure, which could remove the persistent discrepancy between the SAGE and GALLEX calibration measurements performed with neutrinos from reactor-produced 51 Cr and 37 Ar sources and the theoretical expectation

  2. Design and testing of the measuring equipment for the detection of 71Ge and 69Ge within the gallium-solar-neutrino experiment

    International Nuclear Information System (INIS)

    Huebner, M.

    1980-01-01

    A low level measuring system has been developed for the Ga-solar-neutrino experiment, to detect the reaction 71 Ga (νsub(e),e - ) 71 Ge by the decay 71 Ge (Tsub(1/2) = 11. 4 d, 100% electron capture). An estimate based on the solar standard model gives 15 71 Ge atoms produced by solar neutrinos (pp and pep). As a monitor for background reactions in the target, the detectability of the 69 Ga (p,n) 69 Ge reaction by the decay 69 Ge (Tsub(1/2) = 39 h, 37% β + -decay, 63% electron capture) has been considered. To test the system, the detectors are mounted in a low level laboratory lead box. (orig./WB) [de

  3. Measurement of excited states in 71Ge via (p, nγ) reaction and density of discrete levels in 71Ge

    International Nuclear Information System (INIS)

    Razavi, R.; Kakavand, T.; Behkami, A.N.

    2008-01-01

    In all statistical theories the nuclear level density is the most characteristic quantity and plays an essential role in the study of nuclear structure. In this work, additional experimental information about existing level structure of 71 Ge have been provided through the (p, nγ) reaction and then determined nuclear level density parameters of the Bethe formula and constant temperature model for 71 Ge

  4. Effect of chemical structure on the radioactive decay rate of 71Ge

    International Nuclear Information System (INIS)

    Makariunas, K.; Makariuniene, E.; Dragunas, A.

    1979-01-01

    The influence of the chemical structure on the electron capture radioactive decay rate of 71 Ge was observed. 71 Ge nuclei in bivalent sulphide GeS decay faster than in quadrivalent sulphide GeS 2 . The relative change Δlambda/lambda of the decay constant lambda is + (11.4 +- 1.7) X 10 -4 . A possibility to use the experimental values of Δlambda/lambda to determine the chemical changes in the electron density at germanium nuclei in germanium chemical compounds is discussed. Quantitative determination of the changes in the electron density is complicated because of insufficient reliability of the published values of exchange and overlap corrections to the electron capture probabilities. (Auth.)

  5. Radiotracer Generators for Industrial Applications

    International Nuclear Information System (INIS)

    2013-01-01

    restricted because their half-lives are relatively short and only a limited number of radiotracers derived from them have been proven under industrial conditions. Recognizing the potential usefulness of several radionuclide generators, including 68 Ge/ 68 Ga and 137 Cs/ 137 mBa and of radiotracers derived from them, the Agency organized a Coordinated Research Project (CRP) on the Evaluation and Validation of Radionuclide Generator-based Radiotracers for Industrial Applications. The objectives of the CRP , which was implemented over the period 2007-2011, was to coordinate the development of industrial radionuclide generators and to validate generator based radiotracers for use in harsh industrial conditions. It was anticipated that an important outcome would be the production of radionuclide generators designed specifically for industrial purposes. Their cost would be considerably lower than those of medical generators since the high costs of the facilities required to produce generators suitable for in vivo use can be avoided. The IAEA facilitates the transfer of technology, and an important part of this process is the provision of relevant literature that may be used for reference purposes or as an aid to teaching. This monograph contains guidelines for the selection and preparation of radiotracers derived from radionuclide generators, as well as reports from participants of the CRP

  6. Calculation of the dose distribution in water from {sup 71}Ge K-shell x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang H.; Reece, Warren D.; Poston, John W. Sr. [Department of Nuclear Engineering, Texas A and M University, College Station, TX (United States)

    1997-06-01

    The dose distribution in water from {sup 71}Ge K-shell x-rays (E{sub ave}=9.44 eV) was calculated for various source configurations using both analytic and GS4 Monte Carlo calculations. The point source kernel and the buildup factor are presented. The buildup factor for a point source in water has been found to increase up to about 1.1 as radial distance approaches 1 cm. Comparison between {sup 71}Ge and {sup 90}Sr/Y shows a similarity between their relative dose distribution in water. The dose distribution from a disc source was calculated using the EGS4 code and compared with the results from analytic calculation. Excellent agreement was observed, confirming the validity of analytic calculations. The dose rate at 0.01 cm from a {sup 71}Ge disc source was calculated to be about 1.3x10{sup -5} Gy MBq{sup -1}s{sup -1}. Based on the results from his study, {sup 71}Ge activity of the order of 3.7x10{sup 10} Bq({approx}1 Ci) might be necessary to obtain dose rates typical of {sup 90}Sr/Y ophthalmic applicators. The possibility of using {sup 71}Ge as a source of radioactive stents was also investigated. A {sup 71}Ge stent was modelled as a cylindrical shell source and the dose rates were determined by Monte Carlo calculations. Some calculated results are compared with published values for a {sup 32}P-coated stent. The dose rate at 0.01 cm from a {sup 71}Ge stent has been calculated to be about .5x10{sup -3} Gy MBq{sup -1}h{sup -1}, which is much lower than the reported dose rate at the same distance from a {sup 32}P-coated stent. However, an initial source activity of the order of 3.7x10{sup 7} Bq ({approx}1 mCi) would easily result in a typical target dose ({approx}24 Gy) needed for intravascular stent applications. In conclusion, {sup 71}Ge sources could be used as alternatives to beta sources and, unlike high-energy ({approx}MeV) beta sources, may provide easily predictable dose distributions in heterogeneous media and low dose rates, which might be beneficial for

  7. 70Ge, 72Ge, 74Ge, 76Ge(d,3He)69Ga, 71Ga, 73Ga, 75Ga reactions at 26 MeV

    International Nuclear Information System (INIS)

    Rotbard, G.; La Rana, G.; Vergnes, M.; Berrier, G.; Kalifa, J.; Guilbaut, G.; Tamisier, R.

    1978-01-01

    The 70 Ge, 72 Ge, 74 Ge, 76 Ge(d, 3 He) 69 Ga, 71 Ga, 73 Ga, 75 Ga reactions have been studied at 26 MeV with 15 keV resolution (F.W.H.M), using the Orsay MP tandem accelerator and a split pole magnetic spectrometer. The spectroscopic factors are determined for 15 levels in 69 Ga and 11 levels in each of the 3 other Ga isotopes. Level schemes are proposed for the practically unknown 73 Ga and 75 Ga. Very simple model wave functions previously proposed for Ge nuclei are seen to reproduce quite well the measured occupation numbers for the proton orbitals. Anomalies in these occupation numbers are observed between Z=31 and 32 and between N=40 and 42, this last one corresponding to the structural transition observed recently in a comparison of the (p,t) and (t,p) reactions. These anomalies could be related to changes in the nuclear shape

  8. Development of Radiotracer Techniques in Industry

    International Nuclear Information System (INIS)

    Wardono

    2000-01-01

    Contribution of radiotracer techniques to solve problems in industrial process plants have been recognized since a long time. Radiotracer application was governed by three main components, namely radioisotopes, radiation detection and data interpretation of an experiment. The three main components mentioned above have been continually developed to overcome problems relating to the operation of industrial process plants. The availability of isotope generator is one of the development aspect in radiotracer technique. Radiation hazard in radiotracer experiment may be reduced by applying isotope generator and on the other hand the delivery of radiotracer to the plant site from the radioisotopes producer was made easier. The development of microprocessor in computer system has facilitated data recording, storing and retrieving. Development in mathematical model supported by radiotracer experiment enhance data interpretation and shed light on various phenomena of flow process. Generally a flow dynamic in a process plant in all kind of industries can be studied using radiotracer technique. However the main challenge coming from petroleum, petrochemical and mineral processing industries

  9. Research reactors serving the radiotracer technique: An overlooked opportunity?

    International Nuclear Information System (INIS)

    Bode, P.

    2010-01-01

    The unique features of using radiotracers are not always fully explored at nuclear research reactor centers. The radiotracer method is a versatile and powerful tool in the study of a wide variety of applications in e.g. chemistry, biology, agriculture, medicine and (industrial) technology. The big advantage of radiotracers above e.g. stable isotope tracers, commonly applied in e.g. nutritional studies, is that radiotracers allow for non-invasive studies of both steady-state and dynamic systems, in equilibrium situations and for transport and exchange phenomena and thus provide information on the chemical and/or physical status of elements. The radiotracer method does not imply huge equipment investments but rather requires that the four interrelated aspects: experimental designs, data treatment including tracer kinetic analysis and data interpretation are careful considered. Radiotracer production with reactors often implies additional fundamental research to use smart nuclear reactions and chemical separations so as to obtain an almost no-carrier added tracer. Nuclear analytical groups, already equipped with gamma-ray spectrometers, can thus extend their research program. Using Ge-spectrometers, multi-labeling experiments are possible which allow for unique applications if different radionuclides exist for the same element, such as 65 Zn and 69m Zn or 64 Cu and 67 Cu. The developments in novel scintillation detectors, room-temperature semiconductor detectors (like CdZnTe) and position-sensitive detectors open the door for an entire new scope of radiotracer applications, such as SPECT. Once applied to in-vitro studies with cell cultures, the nuclear analytical group may position itself into the worlds of medical research, biochemistry and biotechnology. Radiotracers can be used to study the properties of drug-delivering compounds as used in e.g, cancer therapy. Radiotracers can be added as a label to solid particles, to liquids but may also be applied in the

  10. 3. Radiotracers

    International Nuclear Information System (INIS)

    Musilek, L.

    1992-01-01

    The chapter deals with basic characteristics of radiotracer methods, with demands placed on radiotracers, their assets and drawbacks, the applicability of the method to the study of laminar flows, and examples of radiotracer applications in biochemistry, metallurgy, in the investigation of the permeation and passage of gases and liquids, in the examination of wear of machine components, and in criminological practice. An overview of the major radionuclides and of radiotracer applications is given. (Z.S.). 3 tabs., 5 figs., 25 refs

  11. Reactor and /or accelerator: general remarks on strategic considerations in sourcing/producing radiopharmaceuticals and radiotracer for the Philippines

    International Nuclear Information System (INIS)

    Nazarea, A.D.

    1996-01-01

    The most important sources of radionuclides in the world are particle accelerators and nuclear reactors. Since the late 1940's many radiotracers and radiopharmaceuticals have been innovated and conceived, designed, produced and applied in important industrial and clinical/ biomedical settings. For example in the health area, reactor-produced radionuclides have become indispensable for diagnostic imaging involving, in its most recent and advanced development, radioimmunoscintigraphy, which exploits the exquisite ligand-specificity of monoclonal antibodies, reagents which in turn are the products of advances in biotechnology. Thus far, one of the most indispensable radiopharmaceuticals has been 99m Tc, which is usually obtained as a daughter decay product of 99 Mo. In January 1991, some questions about the stability of the worldwide commercial supply of 99 Mo became highlighted when the major commercial world producer of 99 Mo, Nordion International, shut down its facilities temporarily in Canada due to contamination in its main reactor building (see for instance relevant newsbrief in J. Nuclear Medicine (1991): 'Industry agrees to join DOE study of domestic moly-99 production'). With the above background, my remarks will attempt to open discussions on strategic considerations relevant to questions of 'self reliance' in radiotracers/radiopharmaceutical production in the Philippines. For instance, the relevant question of sourcing local radionuclide needs from a fully functioning multipurpose cyclotron facility within the country that will then supply the needs of the local industrial, biomedical (including research) and health sectors; and possibly, eventually acquiring the capability to export to nearby countries longer-lived radiotracers and radiopharmaceuticals

  12. Radiotracer methodology

    International Nuclear Information System (INIS)

    Eng, R.R.

    1988-01-01

    In 1923, George Hevesy demonstrated the distribution of radioactive lead in the horsebean plant. This early demonstration of the potential use of radiotracers in biology was reinforced when J.G. Hamilton and colleagues used iodine-131 for diagnostic purposes in patients. Then in 1950 Cassen et al. designed the first scintillation counter for measuring radioiodine in the body, using calcium tungstate crystals coupled to a photomultiplier tube. This was followed by the development of the Anger camera, which permitted visualization of radiotracer distribution in biological systems. From these significant early discoveries to the present, many advances have been made. They include the discovery and production of many useful radioisotopes; the formulation of these radioisotopes into useful radiotracers; the advent of first- , and second-, and third-generation instrumentation for monitoring in vitro and in vivo distributions of new radiotracers; and the application of this knowledge to allow us to better understand physiological processes and treat disease states. Radiotracer techniques are integral to numerous techniques described in this volume. Autoradiography, nuclear scintigraphy, positron emission tomography, and single-photon emission computed tomography (SPECT) are all dependent on an understanding of radiotracer techniques to properly utilize these probe devices

  13. Radiotracer in industry

    International Nuclear Information System (INIS)

    Jaafar Abdullah

    2005-01-01

    The use of radiotracers for troubleshooting and to investigate process phenomena in industrial plant equipment has specific advantages over conventional tracers. The main advantages of radiotracers owes to its physico-chemical compatibility, high detection sensitivity, ability of number of radiotracers for different phases, stability in harsh industrial environment and limited memory effects. This chapter covers the methodology which includes the selection of radiotracer, radioisotope generators, estimation of amount of radiotracer, injection systems, detection system and safety procedure. Leak detection, this topic discussed the detection by flowrate measurement, detection of RTD measurement, detection by direct tracer, detection in underground pipes using the static method and dynamic method. The topic namely Radiotracers for flowrate measurement discussed the following subjects: flowrate measurement, transit time methods, dilution methods, standards for flow measurement, multi-phase flow measurement. RTD measurement, this topic covers the basic flow concepts, the mathematical modelling, RTD software, bypassing or channelling, recirculation, trickle bed reactors studies, process diagnosis and analysis. Lastly, the topic cover other application of radiotracers in industry discussed the following subtopics: mixing and blending studies, measurement of volume, ventilation studies, oil field investigation, corrosion and wear studies, validation of CFD models

  14. Studies on the electrochemical behaviour of iron by the use of radio-tracer technique, 1. Studies on the electrodeposition and dissolution of iron by the use of radio-tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Moritani, Kimikazu; Ito, Yasuhiko; Kamata, Masahiro; Oishi, Jun

    1984-12-01

    To investigate whether radio-tracer techniques can augment conventional electrochemical techniques, offering useful information about the electrochemical behaviour of iron, the current efficiency of the electrodeposition of iron and the corrosion rate of metallic iron were measured by the radio-tracer method and the results were compared with the results measured by gravimetry and absorption photometry. Major conclusions obtained by the experiments are summarized as: 1) Between ordinary Fe and /sup 59/Fe, no isotope effect was observed. 2) Radiation from /sup 59/Fe had no effect on the electrode reaction. 3) While the use of a Ge semiconductor detector is undoubtedly preferable, Geiger-Mueller counter or NaI(Tl) scintillation counter gave fully satisfactory results. 4) Electrodeposited iron corrodes several times more rapidly than the iron base metal. These results suggests many other interesting applications of the radio-tracer technique when it is desired to obtain more detailed information on the electrochemical behaviour of iron. (author).

  15. Semi-automated lab-on-a-chip for dispensing GA-68 radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Weinberg, Irving [Weinberg Medical Physics LLC, Bethesda, MD (United States)

    2014-03-12

    We solved a technical problem that is hindering American progress in molecular medicine, and restricting US citizens from receiving optimal diagnostic care. Specifically, the project deals with a mother/daughter generator of positron-emitting radiotracers (Ge-68/Ga-68). These generator systems are approved in Europe but cannot be used in the USA, because of safety issues related to possible breakthrough of long-lived Ge-68 (mother) atoms. Europeans have demonstrated abilities of Ga-68-labeled radiotracers to image cancer foci with high sensitivity and specificity, and to use such methods to effectively plan therapy.The USA Food and Drug Administration (FDA) and Nuclear Regulatory Commission (NRC) have taken the position that every patient administration of Ga-68 should be preceded by an assay demonstrated that Ge-68 breakthrough is within acceptable limits. Breakthrough of parent elements is a sensitive subject at the FDA, as evidenced by the recent recall of Rb-82 generators due to inadvertent administrations of Sr-82. Commercially, there is no acceptable rapid method for assaying breakthrough of Ge-68 prior to each human administration. The gamma emissions of daughter Ga-68 have higher energies than the parent Ge-68, so that the shielding assays typically employed for Mo-99/Tc-99m generators cannot be applied to Ga-68 generators. The half-life of Ga-68 is 68 minutes, so that the standard 10-half-life delay (used to assess breakthrough in Sr-82/Rb-82 generators) cannot be applied to Ga-68 generators. As a result of the aforementioned regulatory requirements, Ga-68 generators are sold in the USA for animal use only.The American clinical community’s inability to utilize Ga-68 generators impairs abilities to treat patients domestically, and puts the USA at a disadvantage in developing exportable products. The proposed DOE project aimed to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences

  16. Synthesis of new radiotracers

    International Nuclear Information System (INIS)

    Chahed, Ahlem

    2008-01-01

    The brain's sensibility besides to the rigorous selectivity of changes taking place on brain's barriers leads us to synthesis specifics radiotracers based on diamine ethylene and marked with technetium radioisotope to form a radiotracer able to pass these barriers and diagnose illnesses in an early stage. These radiotracers are tested by a biodistribution on a small animal to be ratified. (Author)

  17. Radiotracer investigations for sediment transport in ports of India

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Goswami, Sunil; Singh, Gursharan

    2013-01-01

    The knowledge of mixing and transport of sediments in coastal region is of vital importance for evaluating suitability of dumping site for dredged sediments produced during maintenance of shipping channels, expansion of existing projects and construction of new projects. Gamma-emitting radiotracers are commonly used for investigation of movement of sediments on seabed using Scandium-46 (scandium glass powder) as radiotracer. The radiotracer is injected on seabed at a desired location and its movement followed over a period of time using waterproof NaI(Tl) scintillation detectors. The recorded data is analyzed to obtain transport parameters and utilized for assessing the suitability of the dumping sites and optimization of the dredging operations. About 70 large-scale investigations have been carried out in different ports in India leading to significant economical benefits to the Ports. Present paper discusses various aspects of the radiotracer technique for sediment transport, methodology of data analysis and a specific case study. (author)

  18. Analyzing power of polarized protons interactions with carbon nuclei at 0.71-3.61 GeV

    International Nuclear Information System (INIS)

    Anoshina, E.V.; Bodyagin, V.A.; Vardanyan, I.N.; Gribushin, A.M.; Ershov, A.A.; Kruglov, N.A.; Sarycheva, L.I.

    1997-01-01

    For the first time at JINR synchrophasotron an experiment in the polarized proton beam was carried out. Beams of polarized protons with energy T p = 0.71-3.61 GeV, polarization P p ≅ 0.5 and intensity I p ≅ 10 6 particles/spell have been formed, their characteristics were investigated, and a possibility to use those beams as initial for physical and methodical investigations has been shown. The proton-carbon interaction analyzing power at the energies of 1.46 and 3.61 GeV has been measured for two values of the scattering angle. 22 refs., 3 figs

  19. Producing infectious enterovirus type 71 in a rapid strategy

    Directory of Open Access Journals (Sweden)

    Qin E-De

    2010-06-01

    Full Text Available Abstract Background Enterovirus 71 (EV71 is an etiologic agent of hand-foot-and-mouth disease (HFMD, and recent HFMD epidemics worldwide have been associated with a severe form of brainstem encephalitis associated with pulmonary edema and high case-fatality rates. EV71 contains a positive-sense single-stranded genome RNA of approximately 7400 bp in length which encodes a polyprotein with a single open reading frame (ORF, which is flanked by untranslated regions at both the 5' and 3' ends. Results A long distance RT-PCR assay was developed to amplify the full length genome cDNA of EV71 by using specific primes carrying a SP6 promoter. Then the in vitro synthesized RNA transcripts from the RT-PCR amplicons were then transfected into RD cells to produce the rescued virus. The rescued virus was further characterized by RT-PCR and indirect fluorescent-antibody (IFA assay in comparison with the wild type virus. The rescued viruses were infectious on RD cells and neurovirulent when intracerebrally injected into suckling mice. Conclusions Thus, we established a rapid method to produce the infectious full length cDNA of EV71 directly from RNA preparations and specific mutations can be easily engineered into the rescued enterovirus genome by this method.

  20. Radiotracers for medical applications

    International Nuclear Information System (INIS)

    Rayudu, G.A.S.

    1983-01-01

    This book discusses the medical applications of radiotracers. Diagnostic uses and pharmacokinetics of isotopes and radiopharmaceuticals is emphasized. The volume one covers the following topics: Radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; /sup 11/C, /sup 13/N, /sup 15/O, /sup 67/Ga. /sup 111/In, /sup 75/Se, /sup 123m/Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented. 272 pp., 7 x 10, 1983, ISBN-0-8493-6016-1

  1. Radiotracer techniques in hydrological studies

    International Nuclear Information System (INIS)

    Oladipo, M.O.A.; Funtua, I.I.

    2000-07-01

    The use of radioactive tracers particularly short-lived radioisotopes frequently offers advantages over conventional methods of analyses. Applications of nuclear techniques in the field of hydrology constitute important and sometimes unique tools for obtaining critical information needed for water resources management. Essentially, radiotracer techniques offer a safe, cost effective and powerful tool in the assessment, management and protection of water resources. The Centre for Energy Research and Training, Ahmadu Bello University, Zaria of late has been offering consultancy services to some industries in the area of radiotracer technique. The first nuclear reactor in Nigeria, the MNSR, is expected to be commissioned in the Centre very soon. Many short-lived radioisotopes such as Cu-64, Ga-72, Br-82, Hg-197 etc which are very important in hydrological studies can be produced by the MNSR facility. This article reports on the basic principles of the technique and its roles in hydrology

  2. Radiotracer properties determined by high performance liquid chromatography: a potential tool for brain radiotracer discovery

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Lewsey, James; Dewar, Deborah; Pimlott, Sally L.

    2012-01-01

    Introduction: Previously, development of novel brain radiotracers has largely relied on simple screening tools. Improved selection methods at the early stages of radiotracer discovery and an increased understanding of the relationships between in vitro physicochemical and in vivo radiotracer properties are needed. We investigated if high performance liquid chromatography (HPLC) methodologies could provide criteria for lead candidate selection by comparing HPLC measurements with radiotracer properties in humans. Methods: Ten molecules, previously used as radiotracers in humans, were analysed to obtain the following measures: partition coefficient (Log P); permeability (P m ); percentage of plasma protein binding (%PPB); and membrane partition coefficient (K m ). Relationships between brain entry measurements (Log P, P m and %PPB) and in vivo brain percentage injected dose (%ID); and K m and specific binding in vivo (BP ND ) were investigated. Log P values obtained using in silico packages and flask methods were compared with Log P values obtained using HPLC. Results: The modelled associations with %ID were stronger for %PPB (r 2 =0.65) and P m (r 2 =0.77) than for Log P (r 2 =0.47) while 86% of BP ND variance was explained by K m . Log P values were variable dependant on the methodology used. Conclusions: Log P should not be relied upon as a predictor of blood-brain barrier penetration during brain radiotracer discovery. HPLC measurements of permeability, %PPB and membrane interactions may be potentially useful in predicting in vivo performance and hence allow evaluation and ranking of compound libraries for the selection of lead radiotracer candidates at early stages of radiotracer discovery.

  3. Role of radiotracer in animal science

    International Nuclear Information System (INIS)

    Sivaprasad, N.

    2015-01-01

    Radiotracers have been used as radiopharmaceuticals for diagnosis and treatment of animal diseases in cattle and pet animals. In fact the veterinary nuclear medicine based on radiotracer as radiopharmaceuticals is established medical technique for functional studies and imaging of vital organs such as heart, lung, brain, spleen, liver, kidney etc for diagnosis as well as treatment of diseases such as cancers in animal. Besides, radiation from radioisotopes has been in use for radiation therapy of cancers in animals. The nuclear imaging using positron emitting radiotracer is gaining importance in the evolution of drug in small animals. In this respect, small animals have also contributed significantly in the development of radiopharmaceuticals particularly for biodistribution and bioscan studies. In fact, the quality control of radiopharmaceuticals in animals to test the safety is a mandatory requirement in the production of radiopharmaceuticals. In brief the animal science has contributed in various areas and facets of radiotracer techniques and its application vice versa the radiotracer techniques have contributed towards the progress of animal science. The animal science in combination with radiotracer has also contributed to the progress of other basic and applied sciences. Thus there exists a bond between radiotracer techniques and animal science. Some aspects of mutual dependence of animal science and radiotracer are elaborated

  4. A philosophy for CNS radiotracer design.

    Science.gov (United States)

    Van de Bittner, Genevieve C; Ricq, Emily L; Hooker, Jacob M

    2014-10-21

    Decades after its discovery, positron emission tomography (PET) remains the premier tool for imaging neurochemistry in living humans. Technological improvements in radiolabeling methods, camera design, and image analysis have kept PET in the forefront. In addition, the use of PET imaging has expanded because researchers have developed new radiotracers that visualize receptors, transporters, enzymes, and other molecular targets within the human brain. However, of the thousands of proteins in the central nervous system (CNS), researchers have successfully imaged fewer than 40 human proteins. To address the critical need for new radiotracers, this Account expounds on the decisions, strategies, and pitfalls of CNS radiotracer development based on our current experience in this area. We discuss the five key components of radiotracer development for human imaging: choosing a biomedical question, selection of a biological target, design of the radiotracer chemical structure, evaluation of candidate radiotracers, and analysis of preclinical imaging. It is particularly important to analyze the market of scientists or companies who might use a new radiotracer and carefully select a relevant biomedical question(s) for that audience. In the selection of a specific biological target, we emphasize how target localization and identity can constrain this process and discuss the optimal target density and affinity ratios needed for binding-based radiotracers. In addition, we discuss various PET test-retest variability requirements for monitoring changes in density, occupancy, or functionality for new radiotracers. In the synthesis of new radiotracer structures, high-throughput, modular syntheses have proved valuable, and these processes provide compounds with sites for late-stage radioisotope installation. As a result, researchers can manage the time constraints associated with the limited half-lives of isotopes. In order to evaluate brain uptake, a number of methods are available

  5. Production of 41Ar and 79Kr gaseous radiotracers for industrial applications

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Jagadeesan, K.C.; Shivarudrappa, V.; Sharma, V.K.; Chitra, S.

    2007-01-01

    Radiotracers are extensively used in many industries for trouble shooting and optimization of process parameters leading to considerable savings in time and huge economic benefits. In chemical and petrochemical industries different gases and vapours flowing in the conversion reactors play a major role in the final production. Gaseous radiotracers are ideal to study hydrodynamics of gas phases in process vessels. 41 Ar and 79 Kr are the preferred gaseous radiotracers for such studies. Owing to the increase in demand from Indian industries for gas phase radiotracers, efforts have been made to produce 41 Ar and 79 Kr indigenously by irradiation of 40 Ar and enriched 78 Kr gaseous targets in research reactors. Prequalification of the containers used, safety aspects concerning accidental rupture and mandatory tests necessary for irradiation of gaseous targets in the reactors have been studied. The paper describes some of the important safety aspects involved and the results of trial irradiations on the production of 41 Ar and 79 Kr radiotracers. Standardization of suitable assay protocols for their regular production and supply for applications in industries is also described. (author)

  6. Shielding required for radiation produced by 15 GeV stored electrons

    International Nuclear Information System (INIS)

    Jenkins, T.M.; McCaslin, J.B.; Thomas, R.H.

    1974-01-01

    The first phase of PEP will consist of a 15 GeV electron and positron storage ring. This note examines the shielding required by such a facility. Shielding of neutrons and muons produced by 200 GeV protons in the second phase of PEP has been discussed in previous notes. 9 refs., 9 figs., 5 tabs

  7. Use of radiotracers for studies of metal sorption behaviour

    International Nuclear Information System (INIS)

    McCubbin, D.; Leonard, K.S.

    1995-01-01

    Radiotracers provide a convenient tool to study the behaviour of metal ions and other contaminants in natural waters. Furthermore, the use of radiotracers in controlled laboratory experiments provides an ideal approach for investigating, in a systematic manner, the role of individual parameters on processes, at mass concentrations found in the environment. A simplistic procedure has been developed to produce a thorium radiotracer ( 234 Th), in a similar chemical form (non-acidic) to that of the aquatic medium under investigation, to determine the kinetics of sorption to marine particulate material. The benefit of this procedure is that the system is likely to be perturbed to a lesser extent by changes in pH and dissolved Th species following tracer addition. Results from filtering different tracer batches through membranes, to determine the sorption characteristics prior to use, indicate that the physico-chemical behaviour of individual batches was extremely variable. Not surprisingly, the amount of uptake immediately following tracer additions to solutions containing marine particulate material was also variable. It is suggested that the role of tracer may be underestimated if added in acid form. Nevertheless, having accounted for the initial sorption, the subsequent uptake between different batches was reasonably reproducible. The usefulness of radiotracers is discussed in the context of these observations

  8. The heritage of radiotracers for PET

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1988-01-01

    The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology. 54 refs

  9. Leak Detection in Heat Exchangers and Underground Pipelines Using Radiotracers. Material for Education and On-The-Job Training for Practitioners of Radiotracer Technology

    International Nuclear Information System (INIS)

    2009-01-01

    The International Atomic Energy Agency plays a major role in facilitating the transfer of radiotracer technology to developing Member States. The use of radiotracer techniques is well established in many Member States; some hundred radiotracer and end user specialists have been trained in radiotracer techniques and their applications; nearly 50 radiotracer laboratories have been working in this field. The training of radiotracer practitioners is vital for the provision of quality services to industry. Leak detection using radiotracer techniques is probably one of the most widespread applications of radiotracers in industrial troubleshooting. Radiotracer techniques are the most competitive for online leak inspection of heat exchangers and buried pipelines. Radiotracers help in early detection of leaks in heat exchangers and underground transporting pipelines, thus saving money, reducing shutdown time, ensuring safe operation and protecting the environment from pollution. The training course series on leak detection in heat exchangers and underground pipelines using radiotracers addresses the needs of the radiotracer groups and their end users. Besides training purposes, this material will assist radiotracer groups in establishing their quality control and accreditation systems. This training course material is based on lecture notes and practical work delivered by many experts in IAEA-supported activities. In particular, the Technical Cooperation Projects implemented under the Regional Cooperative Agreement (RCA) of the IAEA Member States in the Asia and the Pacific Region have been successful in transferring and implementing radiotracer techniques for leak detection to many end users from oil and gas production, oil refineries and the petrochemical industry. The experience obtained in the RCA Region is presented in the training material illustrated with many case studies carried out in several RCA Member States. Lectures and case studies were reviewed by a number

  10. Green chemistry using radiotracers at SINP

    International Nuclear Information System (INIS)

    Lahiri, Susanta

    2006-01-01

    Green chemistry is utilization of set of principles, which restricts the use, or generation of hazardous substances. In this aim, it is necessary to develop alternative methods, or to find greener reagents for minimum utilization of environmentally hostile substances. Radiotracers can be effectively utilized for development of such methods. This article describes the current status of Green Chemistry research using accelerator/reactor produced radionuclides at Saha Institute of Nuclear Physics, Kolkata, India. (author)

  11. The distribution in transverse momentum of 5 GeV/c secondaries produced at 53 GeV in the centre of mass

    CERN Document Server

    Albrow, M G; Bogaerts, A; Bošnjakovič, B; Brooks, J R; Clegg, A B; Erné, F C; Gee, C N P; Kanaris, A D; Lacourt, A; Locke, D H; Loebinger, F K; Murphy, P G; Rudge, A; Sens, Johannes C; Terwilliger, K M; Van der Veen, F

    1972-01-01

    Data are reported on the distribution in transverse momentum of 5 GeV /c pi /sup +or-/, K/sup +or-/, p and p, produced in proton proton collisions at 53 GeV centre of mass energy at the CERN ISR. At this energy the magnitude and p/sub T/ dependence of the invariant cross- section appears to be approximately equal to that at 19 GeV accelerator energy (at the same value of the Feynman variable x), for pi /sup +or-/ and K/sup +/ in the range 0.15

    GeV/c. (6 refs).

  12. $^{31}$Si Self-Diffusion in Si-Ge Alloys and Si-(B-)C-N Ceramics and Diffusion Studies for Al and Si Beam Developments

    CERN Multimedia

    Nylandsted larsen, A; Voss, T L; Strohm, A

    2002-01-01

    An invaluable method for studying diffusion in solids is the radiotracer technique. However, its applicability had been restricted to radiotracer atoms with half-lives $t_{1/2}$ of about 1~d or longer. Within the framework of IS372 a facility was developed in which short-lived radiotracer atoms ( 5min $\\scriptstyle{\\lesssim}$ $t_{1/2}\\scriptstyle{\\lesssim}$1 d ) can be used. For the implantation of the short-lived tracers the facility is flanged to the ISOLDE beamline, and all post-implantation steps required in the radiotracer technique are done in situ.\\\\ After successful application of this novel technique in diffusion studies of $^{11}$C ($t_{1/2}$ = 20.3 min), this experiment aims at performing self-diffusion studies of $^{31}$Si ($t_{1/2}$ = 2.6~h) in Si--Ge alloys and in amorphous Si--(B--)C--N ceramics.\\\\ Our motivation for measuring diffusion in Si--Ge alloys is their recent technological renaissance as well as the purpose to test the prediction that in these alloys the self-diffusion mechanism chang...

  13. Radiotracer injector: An Industrial Application (RIIA)

    International Nuclear Information System (INIS)

    Noraishah Othman; Mohd Arif Hamzah; Fadil Ismail; Nurliyana Abdullah

    2011-01-01

    The radiotracer injector is meant for transferring liquid radiotracer in the system for industrial radiotracer application with minimal radiation exposure to the operator. The motivation of its invention is coming from the experience of the workers who are very concern about the radiation safety while handling with the radioactive source. The idea ensuring the operation while handling the radioactive source is fast and safe without interrupting the efficiency and efficacy of the process. Thus, semi automated device assisting with pneumatic technology is applied for its invention. (author)

  14. GE`s worldwide experience with IFO based gypsum producing flue gas desulfurization systems

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, A. [GE Environmental Systems, Lebanon, PA (United States)

    1994-12-31

    The In-Situ Forced Oxidation (IFO) process to produce gypsum in a commercial scale flue gas desulfurization (FGD) system was first demonstrated by GE Environmental Systems in 1980 at the Monticello Generating Station of Texas Utilities. Since then, the IFO technology developed and demonstrated by GE has become the industry standard and is used extensively on a world-wide basis to produce both commercial and disposable-grade gypsum. The paper gives an overview of the development, demonstration, commercial design and current status of the IFO technology.

  15. Excitation function of ''7''4Ge(n, α)''7''1''mZn reaction in the energy range 13.82-14.70 MeV

    International Nuclear Information System (INIS)

    Halim, M.A.; Hafiz, M.A.; Naher, K.; Miah, R.U.; Ullah, M.R.

    2003-01-01

    The excitation function of the reaction ''7''4Ge(n, α)''7''1''mZn is measured by activation technique using high resolution HPGe detector gamma ray spectroscopy. Monoenergetic neutrons are produced via D-T reaction at J-25 neutron generator facility of the Institute of Nuclear Science and Technology, AERE, Bangladesh. The neutron flux measurement was done at different energy position in the range 13.82-14.70 MeV using the monitor reaction ''2''7Al(n, α)''2''4Na. The measured cross section values along with the literature data are plotted as a function of neutron energy to get the excitation function of the reaction. A theoretical calculation is also performed to produce the excitation function of the investigated reaction using statistical code SINCROS-II. The measured data are to be found to be in good agreement with the literature data and the theoretical cross section values. (author)

  16. Radiotracers in medical applications, vols 1-2

    International Nuclear Information System (INIS)

    Rayudu, G.V.S.

    1983-01-01

    These volumes will serve as a basis for instruction and reference for professionals such as radiopharmaceutical chemists, radiopharmacologists, radiopharmacists, radiobiochemists, and others involved in the medical applications of radiotracers. Vol. I: Topics include radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; 11 C, 13 N, 15 O, 67 Ga. 111 In, 75 Se, /SUP 123m/ Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented

  17. Radiotracer Applications in Wastewater Treatment Plants

    International Nuclear Information System (INIS)

    2011-01-01

    Wastewater containing pollutants resulting from municipal and industrial activities are normally collected in wastewater treatment plants (WWTPs) for processing before discharge to the environment. The WWTPs are the last barrier against contamination of downstream surface waters such as rivers, lakes and sea. Treated wastewater is reused for irrigation, particularly in arid and semi-arid countries. Therefore, it is very important to maintain optimal operating conditions of WWTPs to eliminate or reduce environmental pollution. Wastewater treatment plants are complicated systems, where the processes of mixing, separation, aeration, biological and chemical reactions occur. A WWTP is basically a multiphase system, and the efficiency of an installation strongly depends on liquid, solid and gas phase flow structures and their residence time distributions (RTDs). However, the fluid dynamic properties of such systems are not yet completely understood, rendering difficult the theoretical prediction of important process parameters such as flow rates, phase distributions, mixing and sediment characteristics. Tracer techniques are very useful tools to investigate the efficiency of purification in WWTPs, aiding both their design and performance optimization. There are many kinds of tracers. Radioactive tracers are the most sensitive and are largely used for on-line diagnosis of various operations in WWTPs. The success of radiotracer applications rests upon their extremely high detection sensitivity, and the strong resistance against severe process conditions. During the last few decades, many radiotracer studies have been conducted worldwide for investigation of various installations for wastewater treatment, such as mixer, aeration tank, clarifiers, digester, filter, wetland and oxidation units. Various radiotracer methods and techniques have been developed by individual tracer groups. However, the information necessary for the preservation of knowledge and transfer of

  18. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  19. The spectrum of protons produced in pp collisions at 31 GeV total energy

    CERN Document Server

    Albrow, M G; Barber, D P; Bogaerts, A; Bosnjakovic, B; Brooks, J R; Clegg, A B; Erné, F C; Gee, C N P; Locke, D H; Loebinger, F K; Murphy, P G; Rudge, A; Sens, Johannes C; Van der Veen, F

    1973-01-01

    Data are reported on the distributions in longitudinal and transverse momentum of protons produced in the range 0.5GeV/c)/sup 2/ in proton-proton collisions at 31 GeV c.m. energy at the CERN ISR. The invariant inelastic cross section shows a peak at high longitudinal momenta. The shape of this peak suggests substantial production of states with masses up to at least 7 GeV. (4 refs).

  20. Disposal of radioactive contaminated waste from Ga-68-PET. Calculation of a clearance level for Ge-68+; Entsorgung radioaktiv kontaminierter Reststoffe aus der Ga-68-PET. Berechnung eines Freigabewertes fuer Ge-68+

    Energy Technology Data Exchange (ETDEWEB)

    Solle, Alexander; Wanke, Carsten; Geworksi, Lilli [Medizinische Hochschule Hannover (Germany). Stabsstelle Strahlenschutz und Abt. Medizinische Physik

    2017-05-01

    Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68 minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined.

  1. Diffusion of $^{56}$Co in GaAs and SiGe alloys

    CERN Multimedia

    Koskelo, O K

    2007-01-01

    Following our previous diffusion studies performed with the modified radiotracer technique, we propose to determine the diffusion of cobalt in GaAs and SiGe alloys under intrinsic conditions. In the literature only three previous studies for Co diffusion in GaAs may be found and the results differ by over four orders of magnitude from each other. For Co diffusion in SiGe alloys no previous data is available in the literature. For Co diffusion in Ge one study may be found but the results have been obtained with material having increased dislocation density. For dislocation-free material no previous measurements are available. For such experiments we ask for two runs of 3 shifts (total of 6 shifts) with $^{56}$Co$^{+}$ ion beam.

  2. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  3. Distributed microprocessor automation network for synthesizing radiotracers used in positron emission tomography

    International Nuclear Information System (INIS)

    Russell, J.A.G.; Alexoff, D.L.; Wolf, A.P.

    1984-01-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. 20 refs. (DT)

  4. Radiochemical studies relevant to cyclotron production of the radionuclides 71,72As, 68Ge/68Ga and 76,77,80mBr

    International Nuclear Information System (INIS)

    Shehata, Mohamed Mostafa Mostafa

    2011-01-01

    The radionuclides 71,72,73,74 As, 68 Ge/ 68 Ga and 76,77,80m Br are gaining considerable interest in nuclear medicine. A method for the separation of no-carrier-added arsenic radionuclides from the bulk amount of proton-irradiated GeO 2 target as well as from coproduced radiogallium was developed. The extraction of radioarsenic by different organic solvents from acid solutions containing alkali iodide was studied and optimized. The influence of the concentration of various acids (HCl, HClO 4 , HNO 3 , HBr, H 2 SO 4 ) as well as of KI was studied using cyclohexane. The practical application of the optimized procedure in the production of 71 As and 72 As is demonstrated. The batch yields achieved were in the range of 75-84% of the theoretical values. The radiochemical separation of radiogallium from radiogermanium was studied using ion exchange chromatography (Amberlite IR-120) and solvent extraction (Aliquat 336 in o-xylene). At first optimized methods for the separation of no-carrier-added 68 Ge/ 69 Ge formed via the nat Ga(p,xn) 69 Ge process in a Ga 2 O 3 target and for n.c.a. 67 Ga formed via the nat Zn(p,xn) 67 Ga reaction in a Zn target were developed. Using those radionuclides as tracers several factors affecting the separation of radiogallium from radiogermanium were studied and for each procedure the optimum conditions were determined. The solvent extraction using Aliquat 336 was found to be more suitable and was adapted to the separation of n.c.a. 68 Ga from its parent n.c.a. 68 Ge. The quality of the product thus obtained is discussed. The separation of no-carrier-added radiobromine and no-carrier-added radiogallium from proton irradiated ZnSe target was studied in detail. The adsorption behaviour of n.c.a. radiobromine, n.c.a. radiogallium, zinc and selenium towards the cation-exchange resin Amberlyst 15, in H + form, and towards the anion-exchange resin Dowex 1X10 in Cl - and OH - forms, was investigated. The elution of n.c.a. radiobromine and n

  5. Radiological protection in the use of radiotracers in industrial process

    International Nuclear Information System (INIS)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Thomé, Z.D.

    2017-01-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  6. Radiological protection in the use of radiotracers in industrial process

    Energy Technology Data Exchange (ETDEWEB)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C., E-mail: mara@cnen.gov.br, E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  7. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    Science.gov (United States)

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  8. Synthesis of new technetium brain radiotracers

    International Nuclear Information System (INIS)

    Ben Dhieb, Fatma

    2012-01-01

    The scintigraphic diagnosis is a major mean for detecting neuro degenerative diseases at early stage; this requires specific radiotracers to a particular class of brain receptors. Our goal was the synthesis of radiotracers, cytectrenes derivatives, which are specific to the 5-HT1A receptor, whose dysfunction is an indicator of neuro degeneration. The study of their biodistribution revealed for only one of them, a good brain retention and a retrieval adequate for diagnosis.

  9. Development of equipment and radiotracer experiment using RI labelled sand in the coastal zone

    International Nuclear Information System (INIS)

    Choi, B. J.; Jung, S. H.; Kim, J. B.; Jin, J. H.

    2004-01-01

    On the basis of the radiotracer technology and the related equipments which have been developed for its industrial application through the nuclear long-term research project, a radiotracer study on sediment transport was carried out as a part of the development of the radiotracer technology for a coastal marine environment. The crystalline material doped with iridium having a similar composition and density as those of the bedload sand collected from the research area was produced by the oxide-route method. A radioisotope container was specially designed to inject the radiotracer from 1m above the sea bedload without radioactive contamination during the transport from the nuclear reactor at KAERI. The position data from the DGPS and the radiation measurement data are collected concurrently and stored by means of the application software programmed with the LabVIEW of the National Instrument. The position data is reprocessed to make it represent the real position of the radiation probe under water and not that of the DGPS antenna on board. In order to evaluate the influence of a breakwater on the deviation of the neighboring coastline, the time dependency of the spatial distribution of the sediment was studied in the area through three tracking measurements after the iridium glass was injected. This trial application showed the potential of the radiotracer technology as an important role for maintaining and developing the coastal marine environment in the future

  10. Energy distributions study of spallation neutrons produced at 0 deg. by proton beams (0.8 GeV and 1.6 GeV) and deuteron beams (1.2 and 1.6 GeV)

    International Nuclear Information System (INIS)

    Martinez, Eugenie

    1997-01-01

    We are studying the energy distributions of spallation neutrons produced at 0 deg. by protons of 0.8 GeV up to 1.6 GeV and deuterons of 1.2 and 1.6 GeV with two complementary experimental techniques: the time of flight measurement with tagged incident protons for low energy neutrons (3-400 MeV) and the use of a magnetic spectrometer at high energy (E ≥ 200 MeV). These measurements enable us to measure for the first time the neutron spectra for incident energies higher than 800 MeV. We have compared the double differential cross sections produced with 1.2 GeV protons on several thin targets (Al, Fe, Zr, W, Pb and Th). The neutron production obtained for a lead target is also studied for various energies (0.8 up to 1.6 GeV) and incident particles (p, d). Data are compared with theoretical simulations carried out using the TIERCE system and the intranuclear cascade model of J. Cugnon associated to the decay code of D. Durand. The neutron spectra calculated by using the HETC and MCNP codes, included in TIERCE, are significantly higher than the measured distributions. A better agreement is observed with the results of the Cugnon's cascade model. (author) [fr

  11. Structural, thermal, and photoacoustic study of nanocrystalline Cr{sub 3}Ge produced by mechanical alloying

    Energy Technology Data Exchange (ETDEWEB)

    Prates, P. B.; Maliska, A. M.; Ferreira, A. S. [Departamento de Engenharia Mecânica, Universidade Federal de Santa Catarina, Campus Universitário Trindade, S/N, C.P. 476, 88040-900 Florianópolis, Santa Catarina (Brazil); Poffo, C. M. [Universidade Federal de Santa Catarina, Campus de Araranguá, 88900-000 Araranguá, Santa Catarina (Brazil); Borges, Z. V. [Departamento de Física, Universidade Federal do Amazonas, 3000 Japiim, 69077-000 Manaus, Amazonas (Brazil); Lima, J. C. de, E-mail: fsc1jcd@fisica.ufsc.br [Departamento de Física, Universidade Federal de Santa Catarina, Campus Universitário Trindade, S/N, C.P. 476, 88040-900 Florianópolis, Santa Catarina (Brazil); Biasi, R. S. de [Seção de Engenharia Mecânica e de Materiais, Instituto Militar de Engenharia, 22290-270 Rio de Janeiro (Brazil)

    2015-10-21

    A thermodynamic analysis of the Cr-Ge system suggested that it was possible to produce a nanostructured Cr{sub 3}Ge phase by mechanical alloying. The same analysis showed that, due to low activation energies, Cr-poor crystalline and/or amorphous alloy could also be formed. In fact, when the experiment was performed, Cr{sub 11}Ge{sub 19} and amorphous phases were present for small milling times. For milling times larger than 15 h these additional phases decomposed and only the nanostructured Cr{sub 3}Ge phase remained up to the highest milling time used (32 h). From the differential scanning calorimetry measurements, the Avrami exponent n was obtained, indicating that the nucleation and growth of the nanostructured Cr{sub 3}Ge phase may be restricted to one or two dimensions, where the Cr and Ge atoms diffuse along the surface and grain boundaries. In addition, contributions from three-dimensional diffusion with a constant nucleation rate may be present. The thermal diffusivity of the nanostructured Cr{sub 3}Ge phase was determined by photoacoustic absorption spectroscopy measurements.

  12. Radiotracers inside the system

    International Nuclear Information System (INIS)

    Savio, Eduardo

    2000-01-01

    The radioactive use of a tracer that you incorporated in a biological, physical or chemicals system can be an indicator of some of the following situations: of the system in general, of a property that is wanted to evaluate, of a biochemical, physiological or pathophysiological. One the radiotracers use inside the system presents the following advantages: 1. it is possible to detect them and to measure them with high precision and sensibility, 2. the radioactivity is independent of the pressure, the temperature, the physical or chemical state 3. the radiotracers do affect the system and they can be used as non destructive methods 4. In most of the cases they can be measured in independent form of the matrix, without necessity of a calibration curve

  13. Dose-on-demand production of diverse 18F-radiotracers for preclinical applications using a continuous flow microfluidic system.

    Science.gov (United States)

    Matesic, Lidia; Kallinen, Annukka; Greguric, Ivan; Pascali, Giancarlo

    2017-09-01

    The production of 18 F-radiotracers using continuous flow microfluidics is under-utilized due to perceived equipment limitations. We describe the dose-on-demand principle, whereby the back-to-back production of multiple, diverse 18 F-radiotracers can be prepared on the same day, on the same microfluidic system using the same batch of [ 18 F]fluoride, the same microreactor, the same HPLC column and SPE cartridge to obtain a useful production yield. [ 18 F]MEL050, [ 18 F]Fallypride and [ 18 F]PBR111 were radiolabeled with [ 18 F]fluoride using the Advion NanoTek Microfluidic Synthesis System. The outlet of the microreactor was connected to an automated HPLC injector and following the collection of the product, SPE reformulation produced the 18 F-radiotracer in productions for [ 18 F]MEL050 and [ 18 F]Fallypride were performed at total flow rates of 20μL/min, resulting in 40±13% and 25±13% RCY respectively. [ 18 F]PBR111 was performed at 200μL/min to obtain 27±8% RCY. Molar activities for each 18 F-radiotracer were >100GBq/μmol and radiochemical purities were >97%, implying that the cleaning procedure was effective. Using the same initial solution of [ 18 F]fluoride, microreactor, HPLC column and SPE cartridge, three diverse 18 F-radiotracers could be produced in yields sufficient for preclinical studies in a back-to-back fashion using a microfluidic system with no detectable cross-contamination. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  14. Principles of radiotracer methodology

    Energy Technology Data Exchange (ETDEWEB)

    Kisieleski, W.E.

    1975-06-01

    Information is presented on the properties of radioisotopes and radiations, methods and equipment for radiation detection, safety in handling radioactive materials, the biological effects of radiation, and the design of radiotracer studies. (LCL)

  15. Inhibitive formation of nanocavities by introduction of Si atoms in Ge nanocrystals produced by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Cai, R. S.; Shang, L.; Liu, X. H.; Zhang, Y. J. [The Cultivation Base for State Key Laboratory, Qingdao University, No. 308 Ningxia Road, Qingdao 266071 (China); Wang, Y. Q., E-mail: yqwang@qdu.edu.cn, E-mail: barba@emt.inrs.ca [The Cultivation Base for State Key Laboratory, Qingdao University, No. 308 Ningxia Road, Qingdao 266071 (China); College of Physics Science, Qingdao University, No. 308 Ningxia Road, Qingdao 266071 (China); Ross, G. G.; Barba, D., E-mail: yqwang@qdu.edu.cn, E-mail: barba@emt.inrs.ca [INRS-Énergie, Matériaux et Télécommunications, 1650 boulevard Lionel-Boulet, Varennes Québec J3X 1S2 (Canada)

    2014-05-28

    Germanium nanocrystals (Ge-nc) were successfully synthesized by co-implantation of Si and Ge ions into a SiO{sub 2} film thermally grown on (100) Si substrate and fused silica (pure SiO{sub 2}), respectively, followed by subsequent annealing at 1150 °C for 1 h. Transmission electron microscopy (TEM) examinations show that nanocavities only exist in the fused silica sample but not in the SiO{sub 2} film on a Si substrate. From the analysis of the high-resolution TEM images and electron energy-loss spectroscopy spectra, it is revealed that the absence of nanocavities in the SiO{sub 2} film/Si substrate is attributed to the presence of Si atoms inside the formed Ge-nc. Because the energy of Si-Ge bonds (301 kJ·mol{sup −1}) are greater than that of Ge-Ge bonds (264 kJ·mol{sup −1}), the introduction of the Si-Ge bonds inside the Ge-nc can inhibit the diffusion of Ge from the Ge-nc during the annealing process. However, for the fused silica sample, no crystalline Si-Ge bonds are detected within the Ge-nc, where strong Ge outdiffusion effects produce a great number of nanocavities. Our results can shed light on the formation mechanism of nanocavities and provide a good way to avoid nanocavities during the process of ion implantation.

  16. [Disposal of radioactive contaminated waste from Ga-68-PET - calculation of a clearance level for Ge-68].

    Science.gov (United States)

    Solle, Alexander; Wanke, Carsten; Geworski, Lilli

    2017-03-01

    Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined. Copyright © 2016. Published by Elsevier GmbH.

  17. Disposal of radioactive contaminated waste from Ga-68-PET. Calculation of a clearance level for Ge-68+

    International Nuclear Information System (INIS)

    Solle, Alexander; Wanke, Carsten; Geworksi, Lilli

    2017-01-01

    Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68 minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined.

  18. Polarization of Λ hyperons produced in pp collisions at 19 GeV/c

    International Nuclear Information System (INIS)

    Aahlin, P.; Frodesen, A.G.; Alpgaard, K.; Hulth, P.O.; Svedin, U.; Yamdagni, N.; Hagman, V.-M.; Tuominiemi, J.; Villanen, P.

    1977-05-01

    The polarization of the Λ hyperon produced in the inclusive reaction p+p→Λ+X is measured at 19 GeV/c with a sample of 4975 Λ's. Nonzero values of the polarization are observed for Λ's with transverse momentum larger than 0.6 GeV/c. Somewhat weaker indications of a nonzero effect are seen for values of the Feynman variable |x| larger than 0.8. The triple-Regge formula with only leading Ksup(*) and Ksup(**) trajectories predicts vanishing polarization and is consistent with data at |x| < 0.8 and small transverse momentum. (author)

  19. Radiotracer residence time distribution method for industrial and environmental applications. Material for education and on-the-job training for practitioners of radiotracer technology

    International Nuclear Information System (INIS)

    2008-01-01

    The International Atomic Energy Agency (IAEA) plays a major role in facilitating the transfer of the radiotracer technology to developing Member States. The major radiotracer techniques have been implemented through IAEA technical cooperation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for the education of specialists in different fields of nuclear technologies. This training course material is intended for the cultivation of radiotracer specialists and for continuing technical education of radiotracer practitioners worldwide. The wide interest in radiotracer technology has created the need for high level professional education and training in this field, which are not necessarily covered by traditional university courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Besides educational purposes, this publication will assist developing Member States in establishing their quality control and accreditation systems. This publication is based on lecture notes and practical works delivered by many experts in IAEA-supported activities. Lectures, papers, case studies and software were reviewed by a number of specialists in several meetings

  20. Utility of radiotracer methodology in scientific research of industrial relevancy

    International Nuclear Information System (INIS)

    Kolar, Z.I.

    1990-01-01

    Utilization of radiotracer methodology in industrial research provides substantial scientific rather than directly demonstrable economic benefits. These benefits include better understanding of industrial processes and subsequently the development of new ones. Examples are given of the use of radiotracers in technological studies and the significance of the obtained results is put down. Creative application of radiotracer methodology may contribute to the economic development and technological advancement of all countries including the developing ones. (orig.) [de

  1. Isomeric cross sections of neutron induced reactions on Ge and Ir isotopes

    International Nuclear Information System (INIS)

    Vlastou, R.; Papadopoulos, C.T.; Kokkoris, M.; Perdikakis, G.; Galanopoulos, S.; Patronis, N.; Serris, M.; Perdikakis, G.; Harissopulos, S.; Demetriou, P.

    2008-01-01

    The 72 Ge(n,α) 69m Zn, 74 Ge(n,α) 71m Zn, 76 Ge(n,2n) 75g+m Ge and 191 Ir(n,2n) 190 Ir g+m1 and 191 Ir(n,2n) 190 Ir m2 reaction cross sections were measured from 9.6 to 11.4 MeV relative to the 27 Al(n,α) 24 Na reference reaction via the activation method. The quasi-monoenergetic neutron beams were produced via the 2 H(d,n) 3 He reaction at the 5 MV VdG Tandem T11/25 accelerator of NCSR 'Demokritos'. Statistical model calculations using the codes STAPRE-F and EMPIRE (version 2.19) and taking into account pre-equilibrium emission were performed on the data measured in this work as well as on data reported in literature. (authors)

  2. Light nuclides produced in the proton-induced spallation of {sup 238}U at 1 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Ricciardi, M.V.; Armbruster, P. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Benlliure, J. [Universidad de Santiago de Compostela (ES)] [and others

    2005-09-01

    The production of light and intermediate-mass nuclides formed in the reaction {sup 1}H+{sup 238}U at 1 GeV was measured at the fragment separator (FRS) at GSI, Darmstadt. The experiment was performed in inverse kinematics, shooting a 1 A GeV {sup 238}U beam on a thin liquid-hydrogen target. 254 isotopes of all elements in the range 7{<=}Z{<=}37 were unambiguously identified, and the velocity distributions of the produced nuclides were determined with high precision. The results show that the nuclides are produced in a very asymmetric binary decay of heavy nuclei originating from the spallation of uranium. All the features of the produced nuclides merge with the characteristics of the fission products as their mass increases. (orig.)

  3. Industrial applications of radiotracers in Indonesia

    International Nuclear Information System (INIS)

    Wandowo

    1994-01-01

    Applications of isotopes and radiation have been developed since 1970 at the Centre for Application of Isotopes and Radiation, National Atomic Energy Agency or BATAN. The scope of applications cover various fields, namely, agriculture, medicine, hydrology, sedimentology and industry. The use of radiotracers prove to be very beneficial for problem solving in industrial process plants and this technique will continuously be promoted by BATAN to industries in Indonesia. Several examples of radiotracer applications in industries which have been carried out by the Group of Industry of the Centre for Application of Isotopes and Radiation are presented. (author). 7 refs., 4 figs., 1 tab

  4. Use of Radiotracers to Study Surface Water Processes

    International Nuclear Information System (INIS)

    2015-03-01

    This publication represents a sound knowledge base for the conduct of radiotracer studies in the environment, with papers on radiotracer methodology, radiation protection and regulation, data analysis and modelling. Environmental case histories from five Member States - Australia, Brazil, France, the Republic of Korea and Sweden - provide information on conducting studies involving he use of radioactive tracers. These case histories are not meant as guidelines for preparing a field study but can rather serve as examples of the type, caution and extent of work involved in environmental studies using radiotracers. This publication can provide guidance for conducting potential future training events in the use of radioactive traces in the environment and can serve as a key reference to all concerned directly with surface water processes

  5. Fostering the local production and application of industrial radiotracers in developing countries - IAEA's role

    International Nuclear Information System (INIS)

    Mohammad Haji-Saeid, S.; Jin, Joon-Ha; Ramamoorthy, Natesan; )

    2006-01-01

    Radiotracer techniques provide fast and accurate information for solving various process problems in industrial plants. The IAEA is playing an important role in supporting the development and transfer of radiotracer techniques to developing countries. The IAEA has implemented 5 coordinated research projects (CRP), including two on-going projects, in the field of radiotracer and sealed source applications in industry. The CRPs facilitated the acquisition and dissemination of know-how and technology for wear/corrosion measurement, residence time: distribution (RTD) study, validation of computed fluid dynamics data, industrial process tomography and inter-well connectivity study. A number of technical cooperation projects have been executed to strengthen the capability of radiotracer groups in developing Member States and to create awareness in the industries about the technical and economical benefits of radiotracer technology. The IAEA's regional projects have strongly impacted the transfer and adoption of the techniques. The status of radiotracer use in developing countries reveals that the lack of timely availability of radiotracers as one of the major problems. Development of some radionuclide generators is a possible solution. Cooperation among the international radiotracer communities is necessary to enhance the availability and use of radiotracers in developing countries. (author)

  6. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  7. A built-in radiotracer (24Na) for measuring circulation catalyst rates

    International Nuclear Information System (INIS)

    Domondon, D.B; Berbano, M.C.

    1975-01-01

    A local petroleum refinery intended to calibrate its catalyst flow measuring instrument (propeller blade) using the radioactive tracer technique (RTT). For this purpose, a method of incorporating a suitable radiotracer in commercial catalyst beads had to be found. Two methods of labelling are described. One method involved the incorporation of the radiotracer in a gel of the same composition as the commercial catalyst and subsequent conversion of the gel into a from like that of the commercial catalyst beads. Another method utilized the strong adsorptive properties of the commercial catalyst beads for the chosen isotopes, e.g., 144 Cs, 46 Sc. To effect quantitative adsorption, commercial catalyst beads were simply stirred in a slightly acidic (pH4) chloride solution of the radiotracers for some time. The radiotracers were found to distribute almost uniformly over the entire catalyst surface and no evidence of volatilization of the isotopes from the catalyst surface under condition of use in commercial units was observed. Another probable method was suggested by the Research and Development Division, Philippine Atomic Energy Commission. Aluminium is a major component of the ceramic catalyst beads and sodium is present as impurity. Hence, a radiotracer ( 24 Na) can be formed in the beads by the reaction 23 Na (n,gamma) 24 Na, 27 Al (n,alpha) 24 Na. This possible method of simply irradiating the commercial catalyst beads in the reactor thereby inducing the radiotracer. 24 Na in situ fulfils all the criteria for the selection of an appropriate radiotracer. The method is very simple but reliable

  8. Development and applications of radiotracers technologies and gamma scanning

    International Nuclear Information System (INIS)

    Conejo, Mario; Chaverri, Oscar; Chine, Bruno; Vargas, Celso

    2008-01-01

    The radiotracers and gamma scanning technologies are very consolidated tools for studying, analyzing and evaluating of industrial processes. The development and the results of radiotracers and gamma scanning technologies applied in laboratory and more complex systems, are reported. The radiotracers technology was used to study boron diffusion during the curing process of the wood, to evaluate a lagoon of sewage treatment with aquatic iris plants and to carry out experimental work with controlled variables in a laboratory hydraulic circuit (flow rig). The gamma scanning technique was used to analyze a pilot tower in the laboratories. The main results achieved with the experiments were the following: 1) the boron absorption as a wood curing agent depends on the section of wood exposed to the curing solution; 2) during the tests effectuated with Iodine 131, the aquatic iris plants situated in the water treatment lagoon absorb part of the radiotracer, making difficult the residence time determination; 3) the sensibility of the system Cesium 137 source and detector is sufficiently high and can detect low radioactive absorption materials, situated inside columns with steel walls. (author) [es

  9. The use of radiotracers in natural rubber research in Malaysia

    International Nuclear Information System (INIS)

    Lai, P.F.; Singh, M.M.

    1981-01-01

    Five main areas where radiotracers have been used in research on natural rubber are on studies on the uptake of plant nutrients by Hevea brasiliensis using 32 P, 86 Rb and 45 Ca as tracers; biosynthesis of Hevea rubber using 14 C or 3 H labelled intermediates; translocation and metabolism of 14 C. Ethephon in Hevea brasiliensis; use of radiotracers as analytical tools and adsorption of labelled fatty acid soaps on natural rubber lattices. These studies are discussed to show the powerful tool that radiotracers provide in agricultural, biochemical and chemical research on natural rubber. (author)

  10. Application of radiotracer methods in streamflow measurements

    International Nuclear Information System (INIS)

    Dincer, T.

    1967-01-01

    An attempt is made to evaluate methods using radiotracers in streamflow measurements. The basic principles of the tracer method are explained and background information given. Radiotracers used in stream discharge measurements are discussed and measurements made by different research workers are described. Problems such as adsorption of the tracer and the mixing length are discussed and the potential use of the radioisotopes as tracer in the routine stream-gauging work is evaluated. It is concluded that, at the present stage of development, radiotracer methods do not seem to be ready for routine use in stream-gauging work, and can only be used in some special cases. For gamma-emitting radioisotopes there are problems related to safety, transport and injection which should be solved. Tritium, though a very attractive tracer in some respects, has the disadvantages of having a relatively long half-life and of disturbing the natural tritium levels in the region. Finally, an attempt is made to define the objectives of the research in the field of application of radioisotopes in hydrometry. (author)

  11. A Genomic, Transcriptomic and Proteomic Look at the GE2270 Producer Planobispora rosea, an Uncommon Actinomycete.

    Directory of Open Access Journals (Sweden)

    Arianna Tocchetti

    Full Text Available We report the genome sequence of Planobispora rosea ATCC 53733, a mycelium-forming soil-dweller belonging to one of the lesser studied genera of Actinobacteria and producing the thiopeptide GE2270. The P. rosea genome presents considerable convergence in gene organization and function with other members in the family Streptosporangiaceae, with a significant number (44% of shared orthologs. Patterns of gene expression in P. rosea cultures during exponential and stationary phase have been analyzed using whole transcriptome shotgun sequencing and by proteome analysis. Among the differentially abundant proteins, those involved in protein metabolism are particularly represented, including the GE2270-insensitive EF-Tu. Two proteins from the pbt cluster, directing GE2270 biosynthesis, slightly increase their abundance values over time. While GE2270 production starts during the exponential phase, most pbt genes, as analyzed by qRT-PCR, are down-regulated. The exception is represented by pbtA, encoding the precursor peptide of the ribosomally synthesized GE2270, whose expression reached the highest level at the entry into stationary phase.

  12. Synthesis of new radiotracers based on aniline

    International Nuclear Information System (INIS)

    Ayari, Issra

    2008-01-01

    There are several possible applications of radioactivity, we cite: the study of the functional and neurochirnical aspects related to the brain. This study requires the synthesis of specific radiotracers able to cross their target tissue. The synthesis methods need to be constantly updated to respond to the big demand of this domain. The development of the chemistry of metal complexes helped us to find a stable radiotracer based on aniline and marked with technetium. This stability aI 10wed us to realize a possible biodistribution and to envisage to count the radioactivity and to valid the radiopharmaceutical. (Author)

  13. Synthesis of new radiotracers for tuberculosis diagnosis

    International Nuclear Information System (INIS)

    Keskes, Badis

    2009-01-01

    Tuberculosis remains a worldwide health problem and its diagnosis presents a major challenge. The examinations currently employed are little appreciable and so far there is no reliable diagnosis test. These last years, the development of the new radiopharmaceuticals, referred to diagnosis, has revived interest in the search for new molecules with a tropism to a particular disease. Thanks to this field, which lies at the interface of organic and organometallic chemistry, nuclear medicine and biology, we have been led to synthesize a technetium radiotracer linked to isoniazid. For the identification of this radiotracer, we used its similar rhenium model. (Author)

  14. Synthesis of new radiotracers based of Ethyl Ester

    International Nuclear Information System (INIS)

    Trabelsi, Donia

    2008-01-01

    The in vivo study of a biochemical or physiological process requires the synthesis of specific radiotracers but also the targeting of these compounds so that they can reach their target tissue. Methodologies original synthesis associated with radioisotopes used, the quantities and chemical forms often have to be available developed. The chemistry of metal complexes booming, we were able to use the ethyl ester combined with technetium, forming a stable radiotracer. Finally, a counting of radioactivity in different rat's organs completed our study. (Author)

  15. Radiotracer studies for coastal zone management

    International Nuclear Information System (INIS)

    Hughes, C.; Kluss, T.; Airey, P.

    2001-01-01

    Coastal engineers and coastal zone managers increasingly rely on numerical models of fluid, sediment and contaminant dynamics. These are used to underpin coastal structure design and to predict environmental response to specific events such as storms or pollutant spills, and gradual changes such as sea-level rise or changes in bathymetry. Radiotracer techniques can be used to provide dynamic data on the movement of a specific patch of water, sediment or pollutant over time, which can be compared with model predictions. Two case studies are presented where radiotracer studies were used to improve confidence in numerical models of: (1) 2D hydrodynamics and sediment transport at the Port of Songkhla, Thailand; and (2) 3D hydrodynamics and algal bloom transport in Manila Bay, Philippines

  16. CFD simulation of homogenisation time measured by radiotracers

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostik, M.; Jahoda, M.

    2004-01-01

    A methodology for CFD (Computational Fluid Dynamics) simulation of radiotracer experiments was suggested. The most important parts of the methodology for validation of CFD results by radiotracers are: a) successful simulation of tracer experiment by CFD code (numerical solution of tracer dispersion in a stirred tank), which results in tracer concentration field at several time intervals; b) post-process data treatment, which uses detection chain description and which enables to simulate the detector measurement of homogenisation time from the tracer concentration field evaluated by CFD code. (author)

  17. Pseudorapidity distributions of charged particles produced in bar pp interactions at √s =630 and 1800 GeV

    International Nuclear Information System (INIS)

    Abe, F.; Amidei, D.; Apollinari, G.; Ascoli, G.; Atac, M.; Auchincloss, P.; Baden, A.R.; Barbaro-Galtieri, A.; Barnes, V.E.; Bedeschi, F.; Belforte, S.; Bellettini, G.; Bellinger, J.; Bensinger, J.; Beretvas, A.; Berge, P.; Bertolucci, S.; Bhadra, S.; Binkley, M.; Blair, R.; Blocker, C.; Bofill, J.; Booth, A.W.; Brandenburg, G.; Brown, D.; Byon, A.; Byrum, K.L.; Campbell, M.; Carey, R.; Carithers, W.; Carlsmith, D.; Carroll, J.T.; Cashmore, R.; Cervelli, F.; Chadwick, K.; Chapin, T.; Chiarelli, G.; Chinowsky, W.; Cihangir, S.; Cline, D.; Connor, D.; Contreras, M.; Cooper, J.; Cordelli, M.; Curatolo, M.; Day, C.; DelFabbro, R.; Dell'Orso, M.; DeMortier, L.; Devlin, T.; DiBitonto, D.; Diebold, R.; Dittus, F.; DiVirgilio, A.; Elias, J.E.; Ely, R.; Errede, S.; Esposito, B.; Flaugher, B.; Focardi, E.; Foster, G.W.; Franklin, M.; Freeman, J.; Frisch, H.; Fukui, Y.; Garfinkel, A.F.; Giannetti, P.; Giokaris, N.; Giromini, P.; Gladney, L.; Gold, M.; Goulianos, K.; Grosso-Pilcher, C.; Haber, C.; Hahn, S.R.; Handler, R.; Harris, R.M.; Hauser, J.; Hessing, T.; Hollebeek, R.; Hu, P.; Hubbard, B.; Hurst, P.; Huth, J.; Jensen, H.; Johnson, R.P.; Joshi, U.; Kadel, R.W.; Kamon, T.; Kanda, S.; Kardelis, D.A.; Karliner, I.; Kearns, E.; Kephart, R.; Kesten, P.; Keutelian, H.; Kim, S.; Kirsch, L.; Kondo, K.; Kruse, U.; Kuhlmann, S.E.; Laasanen, A.T.; Li, W.; Liss, T.; Lockyer, N.; Marchetto, F.; Markeloff, R.; Markosky, L.A.; McIntyre, P.; Menzione, A.; Meyer, T.; Mikamo, S.; Miller, M.; Mimashi, T.; Miscetti, S.; Mishina, M.; Miyashita, S.; Mondal, N.; Mori, S.; Morita, Y.; Mukherjee, A.; Newman-Holmes, C.; Nodulman, L.; Paoletti, R.; Para, A.; Patrick, J.; Phillips, T.J.; Piekarz, H.; Plunkett, P.; Pondrom, L.; Proudfoot, J.; Punzi, G.; Quarrie, D.; Ragan, K.; Redlinger, G.; Rhoades, J.; Rimondi, F.; Ristori, L.; Rohaly, T.; Roodman, A.; Sansoni, A.; Sard, R.; Scarpine, V.; Schlabach, P.; Schmidt, E.E.; Schoessow, P.; Schub, M.H.; Schwitters, R.; Scribano, A.; Segler, S.

    1990-01-01

    We present measurements of the pseudorapidity (η) distribution of charged particles (dN ch /dη) produced with |η|≤3.5 in proton-antiproton collisions at √s of 630 and 1800 GeV. We measure dN ch /dη at η=0 to be 3.18±0.06(stat)±0.10(syst) at 630 GeV, and 3.95±0.03(stat)±0.13(syst) at 1800 GeV. Many systematic errors in the ratio of dN ch /dη at the two energies cancel, and we measure 1.26±0.01±0.04 for the ratio of dN ch /dη at 1800 GeV to that at 630 GeV within |η|≤3. Comparing to lower-energy data, we observe an increase faster than ln(s) in dN ch /dη at η=0

  18. Application of 140La and 24Na as intrinsic radiotracers for investigating catalyst dynamics in FCCUs.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Nair, A G C; Tomar, B S; Nathaniel, T N; Reddy, A V R; Singh, Gursharan

    2009-09-01

    Instrumental neutron activation analysis (INAA) of fluid catalytic cracking (FCC) catalyst samples was carried out with an objective to identify activable elements and evaluate its suitability for use as an intrinsic radiotracer for tracing catalyst itself in Fluid Catalytic Cracking Units (FCCUs) used in petroleum refining. Two catalyst samples obtained from two different refineries were analyzed. Twelve different elements were identified in each catalyst sample and their respective concentrations were determined. From the recorded gamma-ray spectra, it was found that lanthanum-140 ((140)La) and sodium-24 ((24)Na) were the predominantly present and suitable radionuclides that could be used as radiotracers for tracing catalyst in FCCUs. Lanthanum being present in much higher concentration forms the major component of the radiotracer after irradiation. Based on the results of INAA, appropriate quantities of the catalyst samples were irradiated with neutrons to produce the desired amount of activity of lanthanum-140 and sodium-24 to be used as radiotracers for tracing the catalyst itself in a pilot as well as an industrial-scale FCCU. The residence time distribution (RTD) of catalyst was measured and analyzed to determine mean residence time (MRT). The axial dispersion model (ADM) was used to simulate the measured RTD data and investigate the degree of axial mixing. The results of the experiments were used to improve the design of pilot-scale FCCU and optimize the performance of the industrial-scale FCCU.

  19. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  20. Current status and trends of cooperation on radiotracer and NCS technologies

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency, Vienna (Austria). Industrial Applications and Chemistry Section

    1997-10-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on `Radiotracer technology for engineering unit operations studies and unit process optimisation` aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on `Multibeam radiogauging for multi-phase systems studies` to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  1. Current status and trends of cooperation on radiotracer and NCS technologies

    International Nuclear Information System (INIS)

    Thereska, J.

    1997-01-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on 'Radiotracer technology for engineering unit operations studies and unit process optimisation' aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on 'Multibeam radiogauging for multi-phase systems studies' to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  2. Search for pair-produced leptoquarks in $e^{+}e^{-}$ interactions at $\\sqrt{s}\\simeq$ 189 -209 GeV

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kramer, T.; Krieger, P.; von Krogh, J.; Kruger, K.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Lettso, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Martin, A.J.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2003-01-01

    A search for pair-produced leptoquarks is performed using e+e- collision events collected by the OPAL detector at LEP at centre-of-mass energies between 189 and 209 GeV. The data sample corresponds to a total integrated luminosity of 596 pb^-1. The leptoquarks are assumed to be produced via couplings to the photon and the Z0. For a given search channel only leptoquark decays involving a single lepton generation are considered. No evidence for leptoquark pair production is observed. Lower limits on masses for scalar and vector leptoquarks are calculated. The results improve most of the LEP limits derived from previous searches for the pair production process by 10-25 GeV, depending on the leptoquark quantum numbers.

  3. Radiotracer investigations in oil production and water injection wells

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1977-01-01

    Injection of gamma emitting radiotracers into oil wells followed by logging provides information on several aspects such as the identification of zones of seepage of water in the water injection wells and also the location of source of water entering oil producting wells. The experience gained in the application of bromine-82 and rubidium-86 as radiotracers in such studies at the Ankleshwar and Kalol oil fields in Gujarat and Nazira in Assam has been briefly reported. (author)

  4. Preliminary study of the use of radiotracers for leak detection in industrial applications

    International Nuclear Information System (INIS)

    Wetchagarun, S; Petchrak, A; Tippayakul, C

    2015-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH 4 Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system. (paper)

  5. Preliminary study of the use of radiotracers for leak detection in industrial applications

    Science.gov (United States)

    Wetchagarun, S.; Petchrak, A.; Tippayakul, C.

    2015-05-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.

  6. History and present status of field application of radiotracers, (2)

    International Nuclear Information System (INIS)

    Koyama, Takeo; Shimizu, Makoto.

    1988-01-01

    In the field of agriculture, radiotracers were first used in 1957 in studies for improvement in fertilizing techniques. Techniques were established for accurate measurement of extremely low radioactivity in crops and for the separate determination of the phosphorus in crops of the fertilizer origin and soil origin. Then, RI or stable isotope tracing test methods were developed using 32 P or 15 N to determine the flow and absorption of fertilizers. Other techniques using radiotracers developed in this period served for the construction of maps of the root activity of crops, investigation of the effects of different fertilizers in farms where double-cropping was practised, identification of suitable fertilizers for orange cultivation, development of new fertilizing techniques for Japanese persimmon cultivation, etc. Practically, no field use of radiotracers has been found since 1970. At present, it is prohibited and replaced by other techniques using stable isotopes, etc. In the field fishery, radiotracers have been used for studies of various dynamic phenomena including the flow of water and deposits in the sea, behaviors of fish, food, chain, circulation of chemical substances in the ecological system, etc. (Nogami, K.)

  7. Diffractively Produced Charm Final States in 800-GeV/c pp Collisions

    Science.gov (United States)

    Wang, M. H.; Berisso, M. C.; Christian, D. C.; Félix, J.; Gara, A.; Gottschalk, E.; Gutiérrez, G.; Hartouni, E. P.; Knapp, B. C.; Kreisler, M. N.; Lee, S.; Markianos, K.; Moreno, G.; Reyes, M. A.; Sosa, M.; Wehmann, A.; Wesson, D.

    2001-08-01

    We report the first observation of diffractively produced open charm in 800-GeV/c pp collisions of the type pp-->pD*X. We measure cross sections of σdiff(D*+) = (0.185+/-0.044+/-0.054) μb and σdiff(D*-) = (0.174+/-0.034+/-0.029) μb. Our measurements are based on 4.3×109 events recorded by FNAL E690 in the fixed-target run of 1991. We compare our results with previous fixed-target charm experiments.

  8. Angular distributions of leptons from J/ψ's produced in 920 GeV fixed-target proton-nucleus collisions

    International Nuclear Information System (INIS)

    Abt, I.; Kisel, I.; Adams, M.; Cruse, C.; Ehret, K.; Funcke, M.; Schwenninger, B.; Wegener, D.; Agari, M.; Bauer, C.; Braeuer, M.; Hofmann, W.; Jagla, T.; Knoepfle, K.T.; Pleier, M.A.; Reeves, K.; Sanchez, F.; Schmelling, M.; Schwingenheuer, B.; Sciacca, F.; Albrecht, H.; Aplin, S.J.; Bagaturia, Y.; Egorytchev, V.; Emeliyanov, D.; Flammer, J.; Goloubkov, D.; Golubkov, Y.; Hohlmann, M.; Lewendel, B.; Lomonosov, B.; Masciocchi, S.; Medinnis, M.; Mevius, M.; Michetti, A.; Negodaev, M.; Noerenberg, M.; Nunez Pardo de Vera, M.T.; Padilla, C.; Ressing, D.; Riu, I.; Rybnikov, V.; Schmidt, B.; Schwarz, A.S.; Soezueer, L.; Somov, A.; Somov, S.; Spengler, J.; Wurth, R.; Aleksandrov, A.; Bohm, G.; Gellrich, A.; Hernandez, J.M.; Mankel, R.; Nowak, S.; Schreiner, A.; Schwanke, U.; Walter, M.; Amaral, V.; Amorim, A.; Bastos, J.; Batista, J.; Carvalho, J.; Silva, L.; Wolters, H.; Aushev, V.; Prystupa, S.; Pugatch, V.; Vassiliev, Yu.; Balagura, V.; Bobchenko, B.; Bogatyrev, A.; Danilov, M.; Essenov, S.; Fominykh, B.; Golutvin, A.; Gouchtchine, O.; Guilitsky, Yu.; Igonkina, O.; Khasanov, F.; Kvaratskheliia, T.; Matchikhilian, I.; Mikhailov, Yu.; Mizuk, R.; Popov, V.; Rostovtseva, I.; Tikhomirov, I.; Titov, M.; Zaitsev, Yu.; Zhelezov, A.; Bargiotti, M.; Bertin, A.; Bruschi, M.; De Castro, S.; Fabbri, L.; Faccioli, P.; Giacobbe, B.; Grimaldi, F.; Massa, I.; Piccinini, M.; Poli, M.; Semprini-Cesari, N.; Spighi, R.; Villa, M.; Vitale, A.; Zoccoli, A.; Barsukova, O.; Belkov, A.; Belkov, Ar.; Belotelov, I.; Golutvin, I.; Karpenko, N.; Kiryushin, Yu.; Lanyov, A.; Solunin, S.; Bauer, T.S.; Hulsbergen, W.; Sbrizzi, A.; Boecker, M.; Buchholz, P.; Husemann, U.; Keller, S.; Walenta, A.H.; Werthenbach, U.; Bruinsma, M.; Ouchrif, M.; Buran, T.; Danielsen, K.M.; Ould-Saada, F.; Pylypchenko, Y.; Conde, P.; Dam, M.; Groth-Jensen, J.; Hansen, J.D.; Klinkby, E.; Muresan, R.; Petersen, B.AA.; Xella-Hansen, S.; Deppe, H.; Dreis, H.B.; Eisele, F.; Feuerstack-Raible, M.; Gradl, S.; Gradl, W.; Hott, T.; Kessler, J.; Krauss, C.; Rick, H.; Uwer, U.; Dong, X.; Jiang, C.; Zheng, Z.; Garrido, Ll.; Peralta, D.; Glaess, J.; Maenner, R.; Wurz, A.; Gorbounov, I.; Zeuner, T.; Gorisek, A.; Kupper, S.; Pestotnik, R.; Staric, M.; Zivko, T.; Goulart, D.C.; Schwartz, A.J.; Ispiryan, M.; Lau, K.; Pyrlik, J.; Subramania, H.S.; Kapitza, H.; Symalla, M.; Eldik, C. van; Karabekyan, S.; Pernack, R.; Schroeder, H.; Zimmermann, R.; Kolanoski, H.; Kruecker, D.; Lohse, T.; Medin, G.; Nedden, M. zur; Stegmann, C.; Korpar, S.; Kreuzer, P.; Krizan, P.; Stanovnik, A.; Pose, D.; Robmann, P.; Shuvalov, S.; Spiridonov, A.; Tsakov, I.; Vukotic, I.; Wahlberg, H.; Wang, J.J.; Zavertyaev, M.

    2009-01-01

    A study of the angular distributions of leptons from decays of J/ψ's produced in p-C and p-W collisions at √(s)=41.6 GeV has been performed in the J/ψ Feynman-x region -0.34 F 5 J/ψ's reconstructed in both the e + e - and μ + μ - decay channels, indicate that J/ψ's are produced polarized. The magnitude of the effect is maximal at low p T . For p T >1 GeV/c a significant dependence on the reference frame is found: the polar anisotropy is more pronounced in the Collins-Soper frame and almost vanishes in the helicity frame, where, instead, a significant azimuthal anisotropy arises. (orig.)

  9. Application of radiotracers in environmental studies

    International Nuclear Information System (INIS)

    Rathore, V.S.

    1994-01-01

    An attempt has been made to present recently emerging trends in the applicability of radiotracers in environmental studies. Since the topic is of general interest and still in the infancy, basic aspects of sampling, instrumentation and methodology are also covered

  10. Crystal Structures of Yeast-Produced Enterovirus 71 and Enterovirus 71/Coxsackievirus A16 Chimeric Virus-Like Particles Provide the Structural Basis for Novel Vaccine Design against Hand-Foot-and-Mouth Disease.

    Science.gov (United States)

    Lyu, Ke; He, Ya-Ling; Li, Hao-Yang; Chen, Rong

    2015-06-01

    Human enterovirus 71 (EV71) and coxsackievirus A16 (CVA16) are the two major causative agents for hand-foot-and-mouth disease (HFMD). Previously, we demonstrated that a virus-like particle (VLP) for EV71 produced from Saccharomyces cerevisiae is a potential vaccine candidate against EV71 infection, and an EV71/CVA16 chimeric VLP can elicit protective immune responses against both virus infections. Here, we presented the crystal structures of both VLPs, showing that both the linear and conformational neutralization epitopes identified in EV71 are mostly preserved on both VLPs. The replacement of only 4 residues in the VP1 GH loop converted strongly negatively charged surface patches formed by portions of the SP70 epitope in EV71 VLP into a relatively neutral surface in the chimeric VLP, which likely accounted for the additional neutralization capability of the chimeric VLP against CVA16 infection. Such local variations in the amino acid sequences and the surface charge potential are also present in different types of polioviruses. In comparison to EV71 VLP, the chimeric VLP exhibits structural changes at the local site of amino acid replacement and the surface loops of all capsid proteins. This is consistent with the observation that the VP1 GH loop located near the pseudo-3-fold junction is involved in extensive interactions with other capsid regions. Furthermore, portions of VP0 and VP1 in EV71 VLP are at least transiently exposed, revealing the structural flexibility of the VLP. Together, our structural analysis provided insights into the structural basis of enterovirus neutralization and novel vaccine design against HFMD and other enterovirus-associated diseases. Our previous studies demonstrated that the enterovirus 71 (EV71) virus-like particle (VLP) produced from yeast is a vaccine candidate against EV71 infection and that a chimeric EV71/coxsackievirus A16 (CVA16) VLP with the replacement of 4 amino acids in the VP1 GH loop can confer protection against both

  11. Positron Emission Tomography Imaging of Macrophages in Atherosclerosis with 18F-GE-180, a Radiotracer for Translocator Protein (TSPO

    Directory of Open Access Journals (Sweden)

    Sanna Hellberg

    2018-01-01

    Full Text Available Intraplaque inflammation plays an important role in the progression of atherosclerosis. The 18 kDa translocator protein (TSPO expression is upregulated in activated macrophages, representing a potential target to identify inflamed atherosclerotic plaques. We preclinically evaluated 18F-GE-180, a novel third-generation TSPO radioligand, in a mouse model of atherosclerosis. Methods. Nine hypercholesterolemic mice deficient in low density lipoprotein receptor and apolipoprotein B48 (LDLR−/−ApoB100/100 and six healthy C57BL/6N mice were injected with 10 MBq of 18F-GE-180. Specificity of binding was demonstrated in three LDLR−/−ApoB100/100 mice by injection of nonradioactive reference compound of 18F-GE-180 before 18F-GE-180. Dynamic 30-minute PET was performed followed by contrast-enhanced CT, and the mice were sacrificed at 60 minutes after injection. Tissue samples were obtained for ex vivo biodistribution measurements, and aortas were cut into serial cryosections for digital autoradiography. The presence of macrophages and TSPO was studied by immunohistochemistry. The 18F-GE-180 retention in plaque areas with different macrophage densities and lesion-free vessel wall were compared. Results. The LDLR−/−ApoB100/100 mice showed large, inflamed plaques in the aorta. Autoradiography revealed significantly higher 18F-GE-180 retention in macrophage-rich plaque areas than in noninflamed areas (count densities 150 ± 45 PSL/mm2 versus 51 ± 12 PSL/mm2, p<0.001. Prominent retention in the vessel wall without plaque was also observed (220 ± 41 PSL/mm2. Blocking with nonradioactive GE-180 diminished the difference in count densities between macrophage-rich and noninflamed areas in atherosclerotic plaques and lowered the count density in vessel wall without plaque. Conclusion. 18F-GE-180 shows specific uptake in macrophage-rich areas of atherosclerotic plaques in mice. However, retention in atherosclerotic lesions does not

  12. Process and installation for producing tomographic images of the distribution of a radiotracer

    International Nuclear Information System (INIS)

    Fonroget, Jacques; Brunol, Jean.

    1977-01-01

    The invention particularly concerns a process for obtaining tomographic images of an object formed by a radiotracer distributed spacially over three dimensions. This process, using a detection device with an appreciably plane detection surface and at least one collimation orifice provided in a partition between the detection surface and the object, enables tomographic sections to be obtained with an excellent three-dimensional resolution of the images achieved. It is employed to advantage in an installation that includes a detection device or gamma camera on an appreciably plane surface, a device having a series of collimation apertures which may be used in succession, these holes being appreciably distributed over a common plane parallel to the detection surface, and a holder for the object. This holder can be moved in appreciably parallel translation to the common plane. The aim of this invention is, inter alia, to meet two requirements: localization in space and obtaining good contrasts. This aim is achieved by the fact that at least one tomographic image is obtained from a series of intermediate images of the object [fr

  13. Estimation of tritium radiotracer activity for interconnection study in geothermal field

    International Nuclear Information System (INIS)

    Rasi Prasetio; Satrio

    2016-01-01

    Tritium radiotracer (3H) has been applied widely in many geothermal fields around the world. This application was done by injecting radiotracer with certain amount of activity into reinjection well in order to investigate interconnection between reinjection well with surrounding production wells. The activity of injected radiotracer must meets the field condition and the volume of reservoir, detection limit of instrument, as well as safety aspect for the workers and environment from radioactive hazard. The planning of injection process must consider the maximum permissible concentration (MPC) and minimum detection limit (MDL). Based on calculation, tritium radiotracer injection in Kamojang geothermal field can be done with minimal activity of 0.15 Ci and maximum 22100 Ci, while in Lahendong field minimum activity of 0.65 Ci and maximum 7230 Ci. In these two injection studies, tritium was detected in monitoring wells between MDL and MPC limit. By using this estimation calculation, the activity of tritium that released into the environment within safety limit, thus monitoring wells with undetectable tritium infer no connectivity between those wells with reinjection well. (author)

  14. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    International Nuclear Information System (INIS)

    Wiebe, L.I.

    1984-01-01

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use. (author)

  15. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    Science.gov (United States)

    Wiebe, Leonard I.

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and (approved) medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use.

  16. Panel discussion: Chemistry aspects of pet radiotracers

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    A panel discussion on the radiotracer development process opened with a question regarding the role of toxicological studies in the process of obtaining a physician-sponsored Investigational New Drug (IND) for a new radiopharmaceutical. Panel members were uniformly supportive of new radiotracer development, expressing their opinions that the regulatory hurdles were there but could be overcome. Several institutions are actively working with regulatory agencies to determine just what toxicology data are relevant to new radiopharmaceutical development in the PET field. The FDA is beginning to understand that the pharmacology of PET tracer doses may be completely different from what is usually important in drug trials. The second part of the panel discussion centered on the role, if any, of the pharmaceutical companies in new radiotracer development. It was pointed out that what the radiochemist is looking for in a radiopharmaceutical is different from what these companies are searching for in a therapeutic drug. Panel and audience members responded to the question: What would a pharmaceutical company gain from collaboration with radiopharmaceutical research laboratories? Several examples were given such as providing crucial data from humans rather than animals; determining individualized drug doses to maximize the therapeutic index of a new drug regimen; and replacing the large amounts of time and money currently invested by drug companies in the radiolabeling and evaluation of metabolites of new drugs

  17. Enhanced charge storage capability of Ge/GeO2 core/shell nanostructure

    International Nuclear Information System (INIS)

    Yuan, C L; Lee, P S

    2008-01-01

    A Ge/GeO 2 core/shell nanostructure embedded in an Al 2 O 3 gate dielectrics matrix was produced. A larger memory window with good data retention was observed in the fabricated metal-insulator-semiconductor (MIS) capacitor for Ge/GeO 2 core/shell nanoparticles compared to Ge nanoparticles only, which is due to the high percentage of defects located on the surface and grain boundaries of the GeO 2 shell. We believe that the findings presented here provide physical insight and offer useful guidelines to controllably modify the charge storage properties of indirect semiconductors through defect engineering

  18. Enhanced charge storage capability of Ge/GeO(2) core/shell nanostructure.

    Science.gov (United States)

    Yuan, C L; Lee, P S

    2008-09-03

    A Ge/GeO(2) core/shell nanostructure embedded in an Al(2)O(3) gate dielectrics matrix was produced. A larger memory window with good data retention was observed in the fabricated metal-insulator-semiconductor (MIS) capacitor for Ge/GeO(2) core/shell nanoparticles compared to Ge nanoparticles only, which is due to the high percentage of defects located on the surface and grain boundaries of the GeO(2) shell. We believe that the findings presented here provide physical insight and offer useful guidelines to controllably modify the charge storage properties of indirect semiconductors through defect engineering.

  19. Radiotracer study of phosphate exchange between whey and casein micelles in cow's milk

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Verburg, T.G.; Dijk, H.J.M. van

    1998-01-01

    Radiotracer method has been applied to study exchange of calcium ions between the whey calcium salts and micellar calcium phosphate (MCP). The present paper deals with a similar study pertaining to phosphate ions. 32 P-labelled Na 2 HPO 4 was used as the radiotracer for inorganic phosphates of milk. After addition of the radiotracer to skimmed-milk, samples were taken regularly for 700 hours. In the samples casein micelles were separated from whey by ultracentrifugation and finally the radiotracer quantity i.e. 32 P-concentration in the whey samples was measured using a Liquid Scintillation Counter. Compartmental analysis and modelling were used to evaluate the thus obtained time curves for radiotracer quantity in whey. This analysis revealed the presence of three phosphate compartments i.e. exchangeable phosphate entities; one being the whey phosphate. The other two are associated with the exchangeable phosphates of MCP. The mean residence times of phosphate in the latter two compartment differ considerably pointing at two distinctly different embeddings of phosphate groups in the structure of the micellar calcium phosphate of the cow's milk casein. The obtained results are in fair agreement with the mentioned model of MCP

  20. Status and perspective on radiotracer technology and development of its equipment in Korea

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee; Jin, Joon Ha

    2003-01-01

    The Korean tracer team was organized under the regular research project in the middle of 1990s. The objective of the project is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems. The Korean tracer team started with basic tracer technologies and basic tools for radiotracer experiment. Under the research project, various equipments and skills for radiotracer have been developed. With these skill and equipment, there have been several demonstration experiments in petrochemical industry and waste water treatment facilities. The direction of research using radiotracer technology is highly reflected by each country's industrial situation. There is overview on how the tracer technology has applied to the industries in Korea in this paper. And the case on the application of radiotracer technology and the development of its equipment in Korea are also introduced in this paper

  1. Molecules for materials: germanium hydride neutrals and anions. Molecular structures, electron affinities, and thermochemistry of GeHn/GeHn- (n = 0-4) and Ge2Hn/Ge2Hn(-) (n = 0-6).

    Science.gov (United States)

    Li, Qian-Shu; Lü, Rui-Hua; Xie, Yaoming; Schaefer, Henry F

    2002-12-01

    The GeH(n) (n = 0-4) and Ge(2)H(n) (n = 0-6) systems have been studied systematically by five different density functional methods. The basis sets employed are of double-zeta plus polarization quality with additional s- and p-type diffuse functions, labeled DZP++. For each compound plausible energetically low-lying structures were optimized. The methods used have been calibrated against a comprehensive tabulation of experimental electron affinities (Chemical Reviews 102, 231, 2002). The geometries predicted in this work include yet unknown anionic species, such as Ge(2)H(-), Ge(2)H(2)(-), Ge(2)H(3)(-), Ge(2)H(4)(-), and Ge(2)H(5)(-). In general, the BHLYP method predicts the geometries closest to the few available experimental structures. A number of structures rather different from the analogous well-characterized hydrocarbon radicals and anions are predicted. For example, a vinylidene-like GeGeH(2) (-) structure is the global minimum of Ge(2)H(2) (-). For neutral Ge(2)H(4), a methylcarbene-like HGë-GeH(3) is neally degenerate with the trans-bent H(2)Ge=GeH(2) structure. For the Ge(2)H(4) (-) anion, the methylcarbene-like system is the global minimum. The three different neutral-anion energy differences reported in this research are: the adiabatic electron affinity (EA(ad)), the vertical electron affinity (EA(vert)), and the vertical detachment energy (VDE). For this family of molecules the B3LYP method appears to predict the most reliable electron affinities. The adiabatic electron affinities after the ZPVE correction are predicted to be 2.02 (Ge(2)), 2.05 (Ge(2)H), 1.25 (Ge(2)H(2)), 2.09 (Ge(2)H(3)), 1.71 (Ge(2)H(4)), 2.17 (Ge(2)H(5)), and -0.02 (Ge(2)H(6)) eV. We also reported the dissociation energies for the GeH(n) (n = 1-4) and Ge(2)H(n) (n = 1-6) systems, as well as those for their anionic counterparts. Our theoretical predictions provide strong motivation for the further experimental study of these important germanium hydrides. Copyright 2002 Wiley

  2. New-generation radiotracers for nAChR and NET

    Energy Technology Data Exchange (ETDEWEB)

    Ding Yushin [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)]. E-mail: ding@bnl.gov; Fowler, Joanna [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2005-10-01

    Advances in radiotracer chemistry and instrumentation have merged to make positron emission tomography (PET) a powerful tool in the biomedical sciences. Positron emission tomography has found increased application in the study of drugs affecting the brain and whole body, including the measurement of drug pharmacokinetics (using a positron-emitter-labeled drug) and drug pharmacodynamics (using a labeled tracer). Thus, radiotracers are major scientific tools enabling investigations of molecular phenomena, which are at the heart of understanding human disease and developing effective treatments; however, there is evidently a bottleneck in translating basic research to clinical practice. In the meantime, the poor ability to predict the in vivo behavior of chemical compounds based on their log P's and affinities emphasizes the need for more knowledge in this area. In this article, we focus on the development and translation of radiotracers for PET studies of the nicotinic acetylcholine receptor (nAChR) and the norepinephrine transporter (NET), two molecular systems that urgently need such an important tool to better understand their functional significance in the living human brain.

  3. pt and xF dependence of the polarization of Σ+ hyperons produced by 800 GeV/c protons

    International Nuclear Information System (INIS)

    Morelos, A.; Albuquerque, I.F.; Bondar, N.F.; Carrigan, R. Jr.; Chen, D.; Cooper, P.S.; Lisheng, D.; Denisov, A.S.; Dobrovolsky, A.V.; Dubbs, T.; Endler, A.M.F.; Escobar, C.O.; Foucher, M.; Golovtsov, V.L.; Gottschalk, H.; Gouffon, P.; Grachev, V.T.; Khanzadeev, A.V.; Kubantsev, M.A.; Kuropatkin, N.P.; Lach, J.; Lang Pengfei; Lebedenko, V.N.; Li Chengze; Li Yunshan; Luksys, M.; Mahon, J.R.P.; McCliment, E.; Newsom, C.; Pommot Maia, M.C.; Samsonov, V.M.; Schegelsky, V.A.; Shi Huanzhang; Smith, V.J.; Fukun, T.; Terentyev, N.K.; Timm, S.; Tkatch, I.I.; Uvarov, L.N.; Vorobyov, A.A.; Yan Jie; Wenheng, Z.; Zheng Shuchen; Zhong Yuanyuan

    1995-01-01

    We utilize the angle and momentum resolution of our apparatus to study the polarization of 375 GeV/c Σ + hyperons produced by 800 GeV/c protons incident on a Cu target. By examining in detail two of our high statistics data samples, we find evidence for structure in the p t dependence of Σ + polarization and are able to extract the x F dependence of the Σ + polarization and compare it with x F behavior in the Λ 0 and Ξ - systems

  4. Observation and study of centrally produced pion clusters in 28.5-GeV/c p-p interactions

    International Nuclear Information System (INIS)

    Erwin, A.R.; Harvey, E.H.; Larson, G.P.; Collins, G.B.; Ficenec, J.R.; Stringfellow, B.C.; Trower, W.P.; Gutay, L.J.; Laasanen, A.; Willmann, R.B.; Anderson, E.W.; Fisher, G.P.; Lazuras, E.; von Lindern, L.; Ramanauskas, A.; Schubelin, P.; Thorndike, A.M.; Turkot, F.

    1976-01-01

    A double-arm spectrometer is used to identify a pion cluster produced in central p-p collisions at 28.5 GeV/c. Cluster properties studied are angular momentum, quantum statistics, multiplicity, and effective mass. There is some speculation on the production mechanism

  5. Regulatory requirements for fluorine 18-labelled radiotracers

    International Nuclear Information System (INIS)

    Prigent, A.

    2005-01-01

    Although European and French regulations define radiopharmaceuticals and their different conditions for use, there is no legal status of the radiotracer. Radiotracer is commonly known as a molecular entity administered in tracer doses, that means at very low masses (e.g., nano-mol amounts) and, consequently, without any pharmacological effect. A radiotracer can meet the specifications of either a radiochemical (usually restricted to research in animal models) or a radiopharmaceutical (human use for diagnostic imaging or research projects). Besides the 'proprietary medicinal product', different status have been defined to allow other uses in humans, referring to 'magistral formula' preparation, 'officinal formula' preparation, investigational medicinal product for clinical trials, or to a radiopharmaceutical with a 'patient named authorization'. However, because of the short half-life of fluorine 18 and expanding development of molecular imaging techniques using positron emission tomography (PET), the current regulation is sometimes considered as inappropriate with regard to the small-size production required for such on-site manufactured radiopharmaceuticals. It is often claimed that it could be very difficult to comply with the current Good Manufactured Practice (cGMP). As previously done for radiopharmaceuticals based on monoclonal antibodies, specific adjustments for PET radiopharmaceuticals are under discussion and the 'note for guidance on radiopharmaceuticals' will be soon revised by the Committee for Medicinal Products for Human Use (CHMP) of the European Medicines Agency (EMEA). In many cases, a status of 'magistral' product might be attributed to a PET radiopharmaceutical manufactured according with European Pharmacopoeia monographs. (author)

  6. Automated PET Radiotracer Manufacture on the BG75 System and Imaging Validation Studies of [18F]fluoromisonidazole ([18F]FMISO).

    Science.gov (United States)

    Yuan, Hong; Frank, Jonathan E; Merrill, Joseph R; Hillesheim, Daniel A; Khachaturian, Mark H; Anzellotti, Atilio I

    2016-01-01

    The hypoxia PET tracer, 1-[18F]fluoro-3-(2-nitro-1Himidazol- 1-yl)-propan-2-ol ([18F]FMISO) is the first radiotracer developed for hypoxia PET imaging and has shown promising for cancer diagnosis and prognosis. However, access to [18F]FMISO radiotracer is limited due to the needed cyclotron and radiochemistry expertise. The study aimed to develop the automated production method on the [18F]FMISO radiotracer with the novel fully automated platform of the BG75 system and validate its usage on animal tumor models. [18F]FMISO was produced with the dose synthesis cartridge automatically on the BG75 system. Validation of [18F]FMISO hypoxia imaging functionality was conducted on two tumor mouse models (FaDu/U87 tumor). The distribution of [18F]FMISO within tumor was further validated by the standard hypoxia marker EF5. The average radiochemical purity was (99±1) % and the average pH was 5.5±0.2 with other quality attributes passing standard criteria (n=12). Overall biodistribution for [18F]FMISO in both tumor models was consistent with reported studies where bladder and large intestines presented highest activity at 90 min post injection. High spatial correlation was found between [18F]FMISO autoradiography and EF5 hypoxia staining, indicating high hypoxia specificity of [18MF]FMISO. This study shows that qualified [18F]FMISO can be efficiently produced on the BG75 system in an automated "dose-on-demand" mode using single dose disposable cards. The possibilities of having a low-cost, automated system manufacturing ([18F]Fluoride production + synthesis + QC) different radiotracers will greatly enhance the potential for PET technology to reach new geographical areas and underserved patient populations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Direct observation of charmed-particle pairs produced in 340 GeV/c negative-pion interactions in an emulsion chamber

    International Nuclear Information System (INIS)

    Fuchi, H.; Hoshino, K.; Miyanishi, M.; Niu, K.; Niwa, K.; Shibuya, H.; Yanagisawa, Y.; Tasaka, S.; Maeda, Y.; Kimura, H.

    1981-01-01

    Among secondaries of 4323 interactions produced in an emulsion chamber exposed to a 340 GeV/c negative ion beam of CERN-SPS, 4 pairs of charmed particles were detected. The mean lifetime of D 0 (D 0 -bar) and the inclusive production cross-section of a charmed particle pair by 340 GeV/c pions were evaluated as (3.1sub(-1.6)sup(+ 2.0)) x 10 - 13 sec and 44 +- 22 μb. (author)

  8. Direct observation of charmed-particle pairs produced in 340 GeV/c negative-pion interactions in an emulsion chamber

    Energy Technology Data Exchange (ETDEWEB)

    Fuchi, H; Hoshino, K; Miyanishi, M; Niu, K; Niwa, K; Shibuya, H; Yanagisawa, Y [Nagoya Univ. (Japan). Dept. of Physics; Ushida, N [Faculty of Education, Aichi University of Education, Kariya, Aichi (Japan); Tasaka, S [Tokyo Univ., Tanashi (Japan). Inst. for Cosmic Ray Research; Maeda, Y

    1981-06-06

    Among secondaries of 4323 interactions produced in an emulsion chamber exposed to a 340 GeV/c negative ion beam of CERN-SPS, 4 pairs of charmed particles were detected. The mean lifetime of D/sup 0/(D/sup 0/-bar) and the inclusive production cross-section of a charmed particle pair by 340 GeV/c pions were evaluated as (3.1sub(-1.6)sup(+ 2.0)) x 10/sup -13/ sec and 44 +- 22 ..mu..b.

  9. Adsorption on smooth electrodes: A radiotracer study

    International Nuclear Information System (INIS)

    Rice-Jackson, L.M.

    1990-01-01

    Adsorption on solids is a complicated process and in most cases, occurs as the early stage of other more complicated processes, i.e. chemical reactions, electrooxidation, electroreduction. The research reported here combines the electroanalytical method, cyclic voltammetry, and the use of radio-labeled isotopes, soft beta emitters, to study adsorption processes at smooth electrodes. The in-situ radiotracer method is highly anion (molecule) specific and provides information on the structure and composition of the electric double layer. The emphasis of this research was on studying adsorption processes at smooth electrodes of copper, gold, and platinum. The application of the radiotracer method to these smooth surfaces have led to direct in-situ measurements from which surface coverage was determined; anions and molecules were identified; and weak interactions of adsorbates with the surface of the electrodes were readily monitored. 179 refs

  10. Radioimmunoassay kit formulation and its validation for serum progesterone using progesterone radiotracer purified by gel filtration

    International Nuclear Information System (INIS)

    Karir, T.; Pal, N.; Sivaprasad, N.

    2003-01-01

    Purification of the radioiodinated progesterone tyrosine methyl ester conjugate by gel filtration and the development, optimization and clinical validation of a direct radioimmunoassay (RIA) of progesterone using this radiotracer are described. High purity radiotracer is essential for the error free performance of any RIA. Progesterone 11α hemisuccinate was conjugated to tyrosine methyl ester (TME) by the mixed anhydride method and this conjugate was then radioiodinated by the chloramine-T method. Purification of the radioiodinated product was carried out by gel filtration. About 12 batches of the radiotracer were prepared and purified. The purification by gel filtration gave reproducible elution pattern and purity. The radiotracer thus purified was found to have consistent quality as compared to that of any other purification methods. Non-specific binding of the radiotracer was found to be 95% as checked by paper electrophoresis. The stability (retention of the immunoreactivity) of the radiotracer was two to three months. No appreciable changes in the assay characteristics were observed during this period. The assay involved 3 hours incubation of progesterone antibody with individual standards or sample and radiotracer at room temperature. The optimized assay was then validated for internal and external quality control parameters. A RIA kit was then formulated with this radiotracer for estimation of progesterone in serum. The assay kit consisted of lyophilized individual standards ranging from 0.25 to 50 ng/ml. The clinical performance of the developed kit was compared with that of a commercial ELISA kit and a correlation of 0.94 was observed. (author)

  11. A study of KK-bar system produced in the reaction Π-p#-> #KK-barn at 63 GeV

    International Nuclear Information System (INIS)

    Palka, H.

    1983-01-01

    An analysis of KK-bar system produced in the reaction Π - p#-> #KK-barn at 63 GeV and measured by ACCMOR (Amsterdam-CERN-Cracow-Munich-Oxford-Rutherford) collaboration at the CERN SPS accelelator is presented. (author)

  12. Validation of 68Ge/68Ga generator processing by chemical purification for routine clinical application of 68Ga-DOTATOC

    International Nuclear Information System (INIS)

    Asti, Mattia; De Pietri, Giovanni; Fraternali, Alessandro; Grassi, Elisa; Sghedoni, Roberto; Fioroni, Federica; Roesch, Frank; Versari, Annibale; Salvo, Diana

    2008-01-01

    Introduction: Imaging of somatostatin receptor expressing tumours has been greatly enhanced by the use of 68 Ga-DOTATOC and PET/CT. Methods: In this work, a purification method for the 68 Ge/ 68 Ga generator eluate and a method to produce 68 Ga-DOTATOC suitable for clinical use were evaluated. The generator eluate was purified and concentrated on a cation-exchange cartridge in HCl/acetone media. The efficacy of this procedure in eliminating metal impurities from the 68 Ga solution was investigated by ICP-MS. The radiotracer quality was evaluated by radio-TLC, GC and γ-ray spectrometry. Results: 68 Ga-DOTATOC preparations (n=33) were carried out with a mean synthesis yield of 59.3±2.8% (not corrected for decay) and a batch activity ranging from 555 to 296 MBq. The radiochemical and radionuclidic purity were >98% and 99.9999%, respectively. With this purification process, >95% of the Fe(III), Zn(II) and Mn(II) were eliminated from the solution. Conclusions: 68 Ga-DOTATOC produced with this method can be efficiently used in nuclear medicine departments for PET evaluations

  13. Spin Parity Measurement of Centrally Produced $\\pi^{+}\\pi^{-}$ in Proton Proton Collisions at 800 GeV/c

    Energy Technology Data Exchange (ETDEWEB)

    Markianos, Kyriacos [Univ. of Massachusetts, Amherst, MA (United States)

    1998-02-01

    Experiment E690 at Fennilab recorded 5.5 billion p + p → p + X events using an 800 GeV/c proton beam and a liquid hydrogen target, during the 1991 fixed target run. We use a 0.5 billion subset of this sample, to study the reaction p + p → Ps + π-)p f for dipion invariant mass between threshold and 2.3 GeV/c2. We perform a partial wave analysis for dipion invariant mass between threshold and 1.5 GeV/c2. The assumption of S-wave dominance near threshold is sufficient to determine a single, continuous solution throughout the considered mass spectrum. Precision measurement of the production amplitude aids the mapping the low lying meson spectrum. Other possible studies using this data sample and analysis technique are: ( l) the extension of the amplitude analysis above the 1.5 Ge V tc2 mass region using a the full event sample, and (2) the study of the produced amplitudes as a function of the relative angle between the two proton planes.

  14. Search for anomalons produced in nuclear emulsion by 1.88A GeV 40Ar ions

    International Nuclear Information System (INIS)

    El-Nadi, M.; Badawy, O.E.; El-Nagdy, M.S.; Sadek, N.M.; El-Sourogy, A.A.; Mosaad, M.M.; El-Bakry, M.N.; El-Hamalawy, A.

    1987-01-01

    The interaction mean free paths of relativistic projectile fragments produced from a 40 Ar beam at 1.88A GeV in nuclear emulsion are measured. No statistically significant anomalously short mean free path is observed for projectile fragments of charges ranging from Ζ = 2 up to Ζ ≥ 10 at such energy. (author)

  15. Investigation of liquid phase axial dispersion in Taylor bubble flow by radiotracer residence time distribution analysis

    Directory of Open Access Journals (Sweden)

    Jin J.H.

    2013-05-01

    Full Text Available A gas-liquid Taylor bubble flow occurs in small diameter channels in which gas bubbles are separated by slugs of pure liquid. This type of flow regime is well suited for solid catalyzed gas-liquid reactors in which the reaction efficiency is a strong function of axial dispersion in the regions of pure liquid. This paper presents an experimental study of liquid phase axial dispersion in a Taylor bubble flow developed in a horizontal tube using high speed photography and radiotracer residence time distribution (RTD analysis. A parametric dependence of axial dispersion on average volume fraction of gas phase was also investigated by varying the relative volumetric flow rates of the two phases. 137mBa produced from a 137Cs/137mBa radionuclide generator was used as radiotracer and measurements were made using the NaI(Tl scintillation detectors. Validation of 137mBa in the form of barium chloride as aqueous phase radiotracer was also carried out. Axial Dispersion Model (ADM was used to simulate the hydrodynamics of the system and the results of the experiment are presented. It was observed that the system is characterized by very high values of Peclet Number (Pe∼102 which reveals an approaching plug type flow. The experimental and model estimated values of mean residence times were observed in agreement with each other.

  16. Leak detection in a high-pressure heat exchanger system in a refinery using radiotracer technique

    International Nuclear Information System (INIS)

    Samantray, J.S.; Sunil Goswami; Sharma, V.K.; Jayashree Biswal; Pant, H.J.

    2014-01-01

    A radiotracer investigation was carried out in a diesel hydrotreater (DHDT) unit in a refinery for leak detection in a breech-lock heat exchanger system. The main objectives of the study were to identify the leaking heat exchanger in a system with six heat exchangers and estimate the leak rate. Bromine-82 as dibromobiphenyl was selected and used as radiotracer for the investigation. The radiotracer was instantaneously injected into the suction end of the feed pump line to the heat exchanger of the DHDT unit. The movement of the tracer was measured at strategically selected locations using NaI(Tl) scintillation detectors. Based upon the results of the radiotracer investigation, it was found that out of six heat exchangers, exchanger E-1F was leaking. (author)

  17. Ge/SiGe superlattices for nanostructured thermoelectric modules

    International Nuclear Information System (INIS)

    Chrastina, D.; Cecchi, S.; Hague, J.P.; Frigerio, J.; Samarelli, A.; Ferre–Llin, L.; Paul, D.J.; Müller, E.; Etzelstorfer, T.; Stangl, J.; Isella, G.

    2013-01-01

    Thermoelectrics are presently used in a number of applications for both turning heat into electricity and also for using electricity to produce cooling. Mature Si/SiGe and Ge/SiGe heteroepitaxial growth technology would allow highly efficient thermoelectric materials to be engineered, which would be compatible and integrable with complementary metal oxide silicon micropower circuits used in autonomous systems. A high thermoelectric figure of merit requires that electrical conductivity be maintained while thermal conductivity is reduced; thermoelectric figures of merit can be improved with respect to bulk thermoelectric materials by fabricating low-dimensional structures which enhance the density of states near the Fermi level and through phonon scattering at heterointerfaces. We have grown and characterized Ge-rich Ge/SiGe/Si superlattices for nanofabricated thermoelectric generators. Low-energy plasma-enhanced chemical vapor deposition has been used to obtain nanoscale-heterostructured material which is several microns thick. Crystal quality and strain control have been investigated by means of high resolution X-ray diffraction. High-resolution transmission electron microscopy images confirm the material and interface quality. Electrical conductivity has been characterized by the mobility spectrum technique. - Highlights: ► High-quality Ge/SiGe multiple quantum wells for thermoelectric applications ► Mobility spectra of systems featuring a large number of parallel conduction channels ► Competitive thermoelectric properties measured in single devices

  18. Ge interactions on HfO2 surfaces and kinetically driven patterning of Ge nanocrystals on HfO2

    International Nuclear Information System (INIS)

    Stanley, Scott K.; Joshi, Sachin V.; Banerjee, Sanjay K.; Ekerdt, John G.

    2006-01-01

    Germanium interactions are studied on HfO 2 surfaces, which are prepared through physical vapor deposition (PVD) and by atomic layer deposition. X-ray photoelectron spectroscopy and temperature-programed desorption are used to follow the reactions of germanium on HfO 2 . Germanium chemical vapor deposition at 870 K on HfO 2 produces a GeO x adhesion layer, followed by growth of semiconducting Ge 0 . PVD of 0.7 ML Ge (accomplished by thermally cracking GeH 4 over a hot filament) also produces an initial GeO x layer, which is stable up to 800 K. PVD above 2.0 ML deposits semiconducting Ge 0 . Temperature programed desorption experiments of ∼1.0 ML Ge from HfO 2 at 400-1100 K show GeH 4 desorption below 600 K and GeO desorption above 850 K. These results are compared to Ge on SiO 2 where GeO desorption is seen at 550 K. Exploiting the different reactivity of Ge on HfO 2 and SiO 2 allows a kinetically driven patterning scheme for high-density Ge nanoparticle growth on HfO 2 surfaces that is demonstrated

  19. Application of Radiotracer Technology on Solving the Unsolved Leak in Lift Pit

    International Nuclear Information System (INIS)

    Mohd Fitri Abdul Rahman; Jaafar Abdullah; Hearie Hassan

    2016-01-01

    Radiotracers have been used in many fields to optimize processes, solve problems, improve product quality, save energy and reduce pollution. The radiotracer technology is a proven reliable technique and recognized by many sectors such as medical, industrial and environmental. In this work, an unsolved leak problem was present in lift pit within a building in Malaysia. Many techniques have applied such as dye techniques, chemical analyses and engineering plaster to overcome the problem. Unfortunately, none of the techniques solve the problem. Radiotracer was used to find the unidentified source of leak. Basically, Technetium (Tc-99m) has been injected to the several injection points and flow of the tracer was monitored with radiation detectors that have been placed at various locations. The results were successful and pinpoint the problems. (author)

  20. Determination of oil reservoir radiotracer (S14CN−) in a single step using a plastic scintillator extractive resin

    International Nuclear Information System (INIS)

    Bagán, H.; Tarancón, A.; Stavsetra, L.; Rauret, G.; García, J.F.

    2012-01-01

    Highlights: ► A new procedure for S 14 CN − radiotracer determination using PS resin was established. ► The minimum detectable activity for a 100 mL sample is 0.08 Bq L −1 . ► The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L −1 . ► PS resin is capable to quantify S 14 CN − radiotracer samples with errors lower than 5%. ► PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S 14 CN − . Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of 14 C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L −1 and 0.31 Bq L −1 , respectively. The established procedure was applied to active samples from oil reservoirs and errors lower than 5% in the sample

  1. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    Science.gov (United States)

    Sugiharto, Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-06-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  2. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    International Nuclear Information System (INIS)

    Sugiharto; Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-01-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  3. Research of pharmacokinetics of L-threonate calcium with 45Ca radiotrace

    International Nuclear Information System (INIS)

    Tong Jian; Niu Huisheng; Li Huaifen

    2001-01-01

    The pharmacokinetics of calcium in L-threonate calcium is studied by radiotrace method. The results show the relationship between drug-time curve, pharmacokinetics parameters and dosage are positive correlation, and calcium distributes in important tissues such as stomach, intestines, blood and bone. In 24 hours, about 40% calcium is drained in urine, 30% calcium is evacuated in feces, 10%-20% calcium deposit in blood or bone. The radiotrace method is a kind of special, sensitive, accurate method of testing calcium metabolism

  4. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  5. KNO type scaling of secondary charged particles produced in 4.5 a GeV 12C-nucleus collisions

    International Nuclear Information System (INIS)

    Khushnood, H.; Singh, Prithipal; Shukla, Praveen Prakash; Saleem Khan, M.

    2011-01-01

    Study of the secondary charged particles produced in heavy ion collisions is attracting a great deal of attention during the recent years. It is reported that the multiplicity distribution of secondary charged particles produced in high energy hadron-hadron and hadron-nucleus collisions Obey Koba, Nielson and Olesen (KNO) scaling. However, no attention has been paid to study the nature of the multiplicity distribution of secondary charged particles produced in relativistic heavy ions reactions. Thus, an attempt has been made to study the multiplicity distribution of secondary charged particles produced in 4.5 A GeV 12 C-nucleus interactions

  6. Diagnosing plant pipeline system performance using radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kasban, H.; Ali, Elsayed H.; Arafa, H. [Engineering Department, Nuclear Research Center, Atomic Energy Authority, Inshas (Egypt)

    2017-02-15

    This study presents an experimental work in a petrochemical company for scanning a buried pipeline using Tc{sup 99m} radiotracer based on the measured velocity changes, in order to determine the flow reduction along a pipeline. In this work, Tc{sup 99m} radiotracer was injected into the pipeline and monitored by sodium iodide scintillation detectors located at several positions along the pipeline. The flow velocity has been calculated between every two consecutive detectors along the pipeline. Practically, six experiments have been carried out using two different data acquisition systems, each of them being connected to four detectors. During the fifth experiment, a bypass was discovered between the scanned pipeline and another buried parallel pipeline connected after the injection point. The results indicate that the bypass had a bad effect on the volumetric flow rate in the scanned pipeline.

  7. Radiotracers for per studies of neurotransmitter binding sites: Design considerations

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    Neurotransmitter binding sites, such as receptors, neuronal uptake systems, and vesicular uptake systems, are important targets for new radiopharmaceutical design. Selection of potential radioligands can be guided by in vitro laboratory data including such characteristics as selectivity and affinity for specific binding sites. However, development of PET radiotracers for use in vivo must include considerations of in vivo pharmacokinetics and metabolism. Introduction of potential radioligands is further narrowed by the demands of the radiochemical synthesis, which must produce radioligands of high chemical and radiochemical purity and of high specific activity. This paper will review examples of previous and current attempts by radiopharmaceutical chemists to meet these demands for new positron emitter-labeled radioligands for PET studies of a wide array of neurotransmitter binding sites

  8. Cross-sections of spallation residues produced in 1A GeV 208Pb on proton reactions

    International Nuclear Information System (INIS)

    Wlazlo, W.; Uniwersytet Jagiellonski, Cracow; Enqvist, T.; Armbruster, P.

    2000-02-01

    Spallation residues produced in 1 GeV per nucleon 208 Pb on proton reactions have been studied using the fragment separator facility at GSI. Isotopic production cross-sections of elements from 61 Pm to 82 Pb have been measured down to 0.1 mb with a high accuracy. The recoil kinetic energies of the produced fragments were also determined. The obtained cross-sections agree with most of the few existing gamma-spectroscopy data. Data are compared with different intranuclear-cascade and evaporation-fission models. Drastic deviations were found for a standard code used in technical applications. (orig.)

  9. Radiotracer experiments and CFD simulation for industrial hydrocyclone performance

    International Nuclear Information System (INIS)

    Stegowski, Z.; Nowak, E.

    2007-01-01

    Hydrocyclone is a device for solid concentration or selection of solid particles from a liquid-solid mixture. It is widely used in the mineral industry for selection of solid particles from a few to a few hundred micrometers. This paper presents a radiotracer experiment and computational simulation of selection of solid particles in a hydrocyclone of Φ-500 μm, which is used in the industrial copper ore concentration process. The simulation, based on computational fluid dynamics (CFD) techniques, allowed obtaining the velocity and concentration distribution for a real mixture flowing in the hydrocyclone. The mixture was composed of water and nine solid phases of different grain sizes. Finally, the selection curve of solid grains was obtained and compared with the experimental radiotracer results. (author)

  10. Industrial applications of radiotracer and sealed source technology promoted by IAEA

    International Nuclear Information System (INIS)

    Joon-Ha Jin; Thereska, J.

    2004-01-01

    Great technical and economical benefits can be obtained by applying radioisotope technologies to various industries. The International Atomic Energy Agency (IAEA) has contributed to the development of radiotracer and sealed source technology as applied to industry and environment through coordinated research projects (CRPs). The mature and competitive techniques have been transferred and implemented to developing countries through the Agency's technical co-operation (TC) projects. The paper presents the main achievements in radiotracer and sealed source technology promoted by IAEA as well as the perspective of the technology transfer to developing countries. (author)

  11. Preparation of special purity Ge - S - I and Ge - Se - I glasses

    Science.gov (United States)

    Velmuzhov, A. P.; Sukhanov, M. V.; Shiryaev, V. S.; Kotereva, T. V.; Snopatin, G. E.; Churbanov, M. F.

    2017-05-01

    The paper considers the new approaches for the production of special pure Ge - S - I and Ge - Se - I glasses via the germanium(IV) iodide, germanium(II) sulfide, as well as the Ge2S3, Ge2S3I2 and Ge2Se3I2 glassy alloys. The glass samples containing 0.03-0.17 ppm(wt) hydrogen impurity in the form of SH-group, 0.04-0.15 ppm(wt) hydrogen impurity in the form of SeH-group, and 0.5-7.8 ppm(wt) oxygen impurity in the form of Ge-O were produced. Using a crucible technique, the single-index [GeSe4]95I5 glass fibers of 300-400 μm diameter were drawn. The minimum optical losses in the best fiber were 1.7 dB/m at a wavelength of 5.5 μm; the background optical losses were within 2-3 dB/m in the spectral range of 2.5-8 μm.

  12. Biological distribution of [18F-FDG] using reactor produced [18F

    International Nuclear Information System (INIS)

    Sierralta, P.; Massardo, T; Gil, M.C; Gonzalez, P; Chandia, M.; Godoy, N.; Troncoso, F

    2002-01-01

    The animal model that relates biodistribution of a substance is fundamental prior to using it in human beings. For the evaluation of myocardial viability after a recent MI, the use of reactor produced [ 18 F]-FDG (a radiotracer usually obtained in Cyclotron) is proposed, production of which has never been attempted in our country. Specific Activities founded in the different tissues after injection of this radiotracer in an animal model were compared with those obtained by other authors with cyclotron [ 18 F]-FDG. No statistically significant differences in the critical organs were found. Hence, reactor produced [ 18 F]-FDG is a useful radiopharmaceutical in cardiac cellular metabolism assessment (author)

  13. 40 CFR 73.71 - Bidding.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Bidding. 73.71 Section 73.71 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Auctions, Direct Sales, and Independent Power Producers Written Guarantee § 73.71 Bidding...

  14. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  16. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  17. Search for pair-produced leptoquarks in $e^{+}e^{-}$ interactions at $\\sqrt{s} \\simeq$ 183 GeV

    CERN Document Server

    Abbiendi, G.; Alexander, G.; Allison, John; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bellerive, A.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bloodworth, I.J.; Bock, P.; Bohme, J.; Boeriu, O.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brigliadori, L.; Brown, Robert M.; Burckhart, H.J.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couchman, J.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Dallison, S.; Davis, R.; De Jong, S.; de Roeck, A.; Dervan, P.; Desch, K.; Dienes, B.; Dixit, M.S.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Estabrooks, P.G.; Etzion, E.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Feld, L.; Ferrari, P.; Fiedler, F.; Fierro, M.; Fleck, I.; Frey, A.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon-Shotkin, S.M.; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Graham, K.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hajdu, C.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Harder, K.; Harel, A.; Hargrove, C.K.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hobson, P.R.; Hocker, James Andrew; Hoffman, Kara Dion; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klier, A.; Kobayashi, T.; Kobel, M.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kyberd, P.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lauber, J.; Lawson, I.; Layter, J.G.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; Lillich, J.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Lu, J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mader, W.; Mannelli, M.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Merritt, F.S.; Mes, H.; Meyer, I.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Quadt, A.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Rosati, S.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schmitt, S.; Schoning, A.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Spagnolo, S.; Sproston, M.; Stahl, A.; Stephens, K.; Stoll, K.; Strom, David M.; Strohmer, R.; Surrow, B.; Talbot, S.D.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomas, J.; Thomson, M.A.; Torrence, E.; Towers, S.; Trefzger, T.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Voss, H.; Wackerle, F.; Wagner, A.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; Wetterling, D.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Zacek, V.; Zer-Zion, D.

    2000-01-01

    A search for pair-produced leptoquarks has been performed using a sample of e+e- collision events collected by the OPAL detector at LEP at e+e- centre-of-mass energies of about 183 GeV. The data sample corresponds to an integrated luminosity of 55.9 pb-1. The leptoquarks were assumed to be produced via couplings to the photon and the Z0 and then to decay within a single fermion generation. No evidence for contributions from leptoquark pair production processes was observed. Lower limits on scalar and vector leptoquark masses are obtained. The existing limits are improved in the region of large decay branching ratio to quark-neutrino.

  18. Research and development in radiotracer methodology and technology

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency (IAEA), Vienna (Austria)

    2001-07-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  19. Research and development in radiotracer methodology and technology

    International Nuclear Information System (INIS)

    Thereska, J.

    2001-01-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  20. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, Jose; Damera Martinez, A.; Ramos Espinosa, K.

    2003-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one a modified SRI, both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented Several trials performed simultaneously at the two Clarifiers demonstrated that the modified SRI was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The non-availability of a flow meter did not allow to extract more information related to some pattern flux anomalies, nevertheless, the radiotracer method was able to detect certain differences between the two clear juice outlet of the modified SRI Clarifier, probably due some problems in the construction of this equipment. This fact so as other goals achieved in this work, show once more the potentiality of the radiotracer method for this type of study related to the hydrodynamic characteristics of industrial facilities. (Author)

  1. SPECT imaging with the serotonin transporter radiotracer [123I]p ZIENT in nonhuman primate brain

    International Nuclear Information System (INIS)

    Cosgrove, Kelly P.; Staley, Julie K.; Baldwin, Ronald M.; Bois, Frederic; Plisson, Christophe; Al-Tikriti, Mohammed S.; Seibyl, John P.; Goodman, Mark M.; Tamagnan, Gilles D.

    2010-01-01

    Introduction: Serotonin dysfunction has been linked to a variety of psychiatric diseases; however, an adequate SPECT radioligand to probe the serotonin transporter system has not been successfully developed. The purpose of this study was to characterize and determine the in vivo selectivity of iodine-123-labeled 2β-carbomethoxy-3β-(4'-((Z)-2-iodoethenyl)phenyl)nortropane, [ 123 I]p ZIENT, in nonhuman primate brain. Methods: Two ovariohysterectomized female baboons participated in nine studies (one bolus and eight bolus to constant infusion at a ratio of 9.0 h) to evaluate [ 123 I]p ZIENT. To evaluate the selectivity of [ 123 I]p ZIENT, the serotonin transporter blockers fenfluramine (1.5, 2.5 mg/kg) and citalopram (5 mg/kg), the dopamine transporter blocker methylphenidate (0.5 mg/kg) and the norepinephrine transporter blocker nisoxetine (1 mg/kg) were given at 8 h post-radiotracer injection. Results: In the bolus to constant infusion studies, equilibrium was established by 4-8 h. [ 123 I]p ZIENT was 93% and 90% protein bound in the two baboons and there was no detection of lipophilic radiolabeled metabolites entering the brain. In the high-density serotonin transporter regions (diencephalon and brainstem), fenfluramine and citalopram resulted in 35-71% and 129-151% displacement, respectively, whereas methylphenidate and nisoxetine did not produce significant changes ( 123 I]p ZIENT is a favorable compound for in vivo SPECT imaging of serotonin transporters with negligible binding to norepinephrine and dopamine transporters.

  2. The Role of Ge Wetting Layer and Ge Islands in Si MSM Photodetectors

    International Nuclear Information System (INIS)

    Mahmodi, H.; Hashim, M. R.

    2010-01-01

    In this work, Ge thin films were deposited on silicon substrates by radio frequency magnetron sputtering to form Ge islands from Ge layer on Si substrate during post-growth rapid thermal annealing (RTA). The size of the islands decreases from 0.6 to 0.1 as the rapid thermal annealing time increases from 30 s to 60 s at 900 deg. C. Not only that the annealing produces Ge islands but also wetting layer. Energy Dispersive X-ray Spectroscopy (EDX) and Scanning Electron Microscopy (SEM) were employed for structural analysis of Ge islands. Metal-Semiconductor-Metal photodetectors (MSM PDs) were fabricated on Ge islands (and wetting layer)/Si. The Ge islands and wetting layer between the contacts of the fabricated devices are etched in order to see their effects on the device. The performance of the Ge islands MSM-PD was evaluated by dark and photo current-voltage (I-V) measurements at room temperature (RT). It was found that the device with island and wetting layer significantly enhance the current gain (ratio of photo current to dark current) of the device.

  3. A study of residence time distribution using radiotracer technique in the large scale plant facility

    Science.gov (United States)

    Wetchagarun, S.; Tippayakul, C.; Petchrak, A.; Sukrod, K.; Khoonkamjorn, P.

    2017-06-01

    As the demand for troubleshooting of large industrial plants increases, radiotracer techniques, which have capability to provide fast, online and effective detections to plant problems, have been continually developed. One of the good potential applications of the radiotracer for troubleshooting in a process plant is the analysis of Residence Time Distribution (RTD). In this paper, the study of RTD in a large scale plant facility using radiotracer technique was presented. The objective of this work is to gain experience on the RTD analysis using radiotracer technique in a “larger than laboratory” scale plant setup which can be comparable to the real industrial application. The experiment was carried out at the sedimentation tank in the water treatment facility of Thailand Institute of Nuclear Technology (Public Organization). Br-82 was selected to use in this work due to its chemical property, its suitable half-life and its on-site availability. NH4Br in the form of aqueous solution was injected into the system as the radiotracer. Six NaI detectors were placed along the pipelines and at the tank in order to determine the RTD of the system. The RTD and the Mean Residence Time (MRT) of the tank was analysed and calculated from the measured data. The experience and knowledge attained from this study is important for extending this technique to be applied to industrial facilities in the future.

  4. Properties of prompt muons produced by 28 GeV proton interactions

    International Nuclear Information System (INIS)

    Morse, W.M.; Lai, K.W.; Larsen, R.C.

    1978-01-01

    Prompt dimuon production from the interactions of 28.5 GeV protons with nuclear targets. The dimuon differential cross section dsigma/dx and the prompt muon to pion ratio are equal within errors to that found at an incident proton beam energy of 400 GeV. The atomic number dependence is found to be the same as that of the total proton nucleon cross section. The dimuon invariant mass distribution is presented. 13 references

  5. The Low Temperature Epitaxy of Strained GeSn Layers Using RTCVD System

    Science.gov (United States)

    Kil, Yeon-Ho; Yuk, Sim-Hoon; Jang, Han-Soo; Lee, Sang-Geul; Choi, Chel-Jong; Shim, Kyu-Hwan

    2018-03-01

    We have investigated the low temperature (LT) growth of GeSn-Ge-Si structures using rapid thermal chemical vapor deposition system utilizing Ge2H6 and SnCl4 as the reactive precursors. Due to inappropriate phenomena, such as, Ge etch and Sn segregation, it was hard to achieve high quality GeSn epitaxy at the temperature > 350 °C. On the contrary, we found that the SnCl4 promoted the reaction of Ge2H6 precursors in a certain process condition of LT, 240-360 °C. In return, we could perform the growth of GeSn epi layer with 7.7% of Sn and its remaining compressive strain of 71.7%. The surface propagated defects were increased with increasing the Sn content in the GeSn layer confirmed by TEM analysis. And we could calculate the activation energies at lower GeSn growth temperature regime using by Ge2H6 and SnCl4 precursors about 0.43 eV.

  6. Ω- produced in K-p reactions at 4.2 GeV/c

    International Nuclear Information System (INIS)

    Hemingway, R.J.; Armenteros, R.; Dionisi, C.; Gavillet, Ph.; Gurtu, A.; Holmgren, S.O.; Losty, M.J.; Marin, J.C.; Mazzucato, M.; Montanet, L.; Banting, M.; Blokzijl, R.; Groot, A.J. de; Jongejans, B.; Kluyver, J.C.; Leeuwen, W.M. van; Massaro, G.G.G.; Tenner, A.G.; Wolters, G.F.; Heinen, P.M.; Kittel, E.W.; Metzger, W.J.; Tiecke, H.G.J.M.; Timmermans, J.J.M.; Walle, R.T. van de; Foster, B.; Grossmann, P.; Lamb, P.R.; Lloyd, J.L.; Wells, J.

    1978-01-01

    Forty Ω - events have been observed in a large (133 events/μb) experiment at 4.2 GeV/c incident K - momentum. Thirty nine of the events come from the three-body reaction K - p→Ω - K + K 0 . The Ω - is mainly produced in the forward hemisphere (direction of the incident K - ). The lifetime is measured to be tau=(0.75(+0.14-0.11))x10 -10 sec., substantially less than the Particle Data Group value of (1.3(+0.3-0.2)x10 -10 sec. The mass is determined to be 1671.7+-0.6 MeV, in good agreement with other determinations. The decay asymmetry parameter α (for the decay mode Ω - →ΛK - ) is found to be -0.2+-0.4. (Auth.)

  7. Genome Sequence Analysis of the Biogenic Amine-Producing Strain Lactococcus lactis subsp. cremoris CECT 8666 (Formerly GE2-14)

    Science.gov (United States)

    del Rio, Beatriz; Linares, Daniel M.; Fernandez, Maria; Mayo, Baltasar; Martin, M. Cruz; Alvarez, Miguel A.

    2014-01-01

    We here report a 2,801,031-bp annotated draft assembly for the Lactococcus lactis subsp. cremoris GE2-14 genome. This dairy strain produces the biogenic amine putrescine. This sequence may help identify the mechanisms regulating putrescine biosynthesis and throw light on ways to reduce its presence in fermented foods. PMID:25342694

  8. XRD analysis of strained Ge-SiGe heterostructures on relaxed SiGe graded buffers grown by hybrid epitaxy on Si(0 0 1) substrates

    International Nuclear Information System (INIS)

    Franco, N.; Barradas, N.P.; Alves, E.; Vallera, A.M.; Morris, R.J.H.; Mironov, O.A.; Parker, E.H.C.

    2005-01-01

    Ge/Si 1-x Ge x inverted modulation doped heterostructures with Ge channel thickness of 16 and 20 nm were grown by a method of hybrid epitaxy followed by ex situ annealing at 650 deg. C for p-HMOS application. The thicker layers of the virtual substrate (6000 nm graded SiGe up to x = 0.6 and 1000 nm uniform composition with x = 0.6) were produced by ultrahigh vacuum chemical vapor deposition (UHV-CVD) while the thinner, Si(2 nm)-SiGe(20 nm)-Ge-SiGe(15 nm + 5 nm B-doped + 20 nm) active layers were grown by low temperature solid-source (LT-SS) MBE at T = 350 deg. C. As-grown and annealed samples were measured by X-ray diffraction (XRD). Reciprocal space maps (RSMs) allowed us to determine non-destructively the precise composition (∼1%) and strain of the Ge channel, along with similar information regarding the other layers that made up the whole structure. Layer thickness was determined with complementary high-resolution Rutherford backscattering (RBS) experiments

  9. Measurements of neutron spectra produced from a thick tungsten target bombarded with 5 and 15 GeV protons

    CERN Document Server

    Meigo, S; Shigyo, N; Iga, K; Iwamoto, Y; Kitsuki, H; Ishibashi, K; Maehata, K; Arima, H; Nakamo, T; Numajiri, M

    2002-01-01

    For validation of calculation codes that are employed in the design of a pulse spallation neutron source and accelerator driven system, the spectrum of neutrons produced from a thick target plays an important role. However, appropriate experimental data were scarce for incident energies higher than 0.8 GeV. In this study, the spectrum from a thick tungsten target was measured. The experiment was carried out at the pi 2 beam line of the 12-GeV proton synchrotron at KEK. The tungsten target was bombarded by 0.5- and 1.5-GeV secondary protons. The spectrum of neutrons was measured by the time-of-flight technique using organic scintillators of NE213. The calculated result with NMTC/JAM and MCNP-4A is compared with the measured data. It is found that the NMTC/JAM generally gives a good agreement with experiment. The NMTC/JAM, however, gives 50% lower neutron flux in the energy region 20~80 MeV, which is consistent with the results in a previous comparison of a lead target. For the neutrons between 20 and 80 MeV, t...

  10. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  11. Search for supersymmetry in the photon(s) plus missing energy channels at sqrt(s)=161 GeV and 172 GeV

    Science.gov (United States)

    ALEPH Collaboration; Barate, R.; Buskulic, D.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Nief, J.-Y.; Pietrzyk, B.; Casado, M. P.; Chmeissani, M.; Comas, P.; Crespo, J. M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, Ll. M.; Padilla, C.; Park, I. C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Bazarko, A. O.; Becker, U.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Dissertori, G.; Drevermann, H.; Forty, R. W.; Frank, M.; Hagelberg, R.; Hansen, J. B.; Harvey, J.; Janot, P.; Jost, B.; Kneringer, E.; Lehraus, I.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.-F.; Ranjard, F.; Rizzo, G.; Rolandi, L.; Rousseau, D.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Teubert, F.; Tomalin, I. R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barrès, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.-M.; Fearnley, T.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Rensch, B.; Wäänänen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J. C.; Machefert, F.; Rougé, A.; Rumpf, M.; Valassi, A.; Videau, H.; Boccali, T.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Huehn, T.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Knowles, I. G.; Lynch, J. G.; O'Shea, V.; Raine, C.; Scarr, J. M.; Smith, K.; Teixeira-Dias, P.; Thompson, A. S.; Thomson, E.; Thomson, F.; Turnbull, R. M.; Buchmüller, O.; Dhamotharan, S.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Girone, M.; Goodsir, S.; Martin, E. B.; Morawitz, P.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Spagnolo, P.; Stacey, A. M.; Williams, M. D.; Ghete, V. M.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Buck, P. G.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Jones, R. W. L.; Sloan, T.; Whelan, E. P.; Williams, M. I.; Giehl, I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Carr, J.; Coyle, P.; Diaconu, C.; Ealet, A.; Fouchez, D.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Talby, M.; Sadouki, A.; Thulasidas, M.; Tilquin, A.; Trabelsi, K.; Aleppo, M.; Antonelli, M.; Ragusa, F.; Berlich, R.; Blum, W.; Büscher, V.; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lütjens, G.; Lutz, G.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, R.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Höcker, A.; Jacholkowska, A.; Jacquet, M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Nikolic, I.; Schune, M.-H.; Serin, L.; Simion, S.; Tournefier, E.; Veillet, J.-J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Ciulli, V.; dell'Orso, R.; Fantechi, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciabà, A.; Sguazzoni, G.; Steinberger, J.; Tenchini, R.; Vannini, C.; Venturi, A.; Verdini, P. G.; Blair, G. A.; Bryant, L. M.; Chambers, J. T.; Gao, Y.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Maley, P.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Fabbro, B.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Kim, H. Y.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Boswell, R.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Kelly, M. S.; Lehto, M.; Newton, W. M.; Reeve, J.; Thompson, L. F.; Affholderbach, K.; Böhrer, A.; Brandt, S.; Cowan, G.; Foss, J.; Grupen, C.; Lutters, G.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R. W.; Armstrong, S. R.; Charles, E.; Elmer, P.; Ferguson, D. P. S.; González, S.; Greening, T. C.; Hayes, O. J.; Hu, H.; Jin, S.; McNamara, P. A., III; Nachtman, J. M.; Nielsen, J.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Scott, I. J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Yamartino, J. M.; Zobernig, G.

    1998-02-01

    Searches for supersymmetric particles in channels with one or more photons and missing energy have been performed with data collected by the ALEPH detector at LEP. The data consist of 11.1 pb-1 at sqrt(s)=161 GeV, 1.1 pb-1 at 170 GeV and 9.5 pb-1 at 172 GeV. The e+e--->νν¯γ(γ) cross section is measured. The data are in good agreement with predictions based on the Standard Model, and are used to set upper limits on the cross sections for anomalous photon production. These limits are compared to two different SUSY models and used to set limits on the neutralino mass. A limit of 71 GeV/c2 at 95% C.L. is set on the mass of the lightest neutralino (τχ10<= 3 ns) for the gauge-mediated supersymmetry breaking and LNZ models. © 1998

  12. Determination of oil reservoir radiotracer (S{sup 14}CN{sup -}) in a single step using a plastic scintillator extractive resin

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Stavsetra, L. [Department for Reservoir and Exploration Technology, Institute for Energy Technology (IFE), Instituttveien 18, N-2027 Kjeller (Norway); Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain)

    2012-07-29

    Highlights: Black-Right-Pointing-Pointer A new procedure for S{sup 14}CN{sup -} radiotracer determination using PS resin was established. Black-Right-Pointing-Pointer The minimum detectable activity for a 100 mL sample is 0.08 Bq L{sup -1}. Black-Right-Pointing-Pointer The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L{sup -1}. Black-Right-Pointing-Pointer PS resin is capable to quantify S{sup 14}CN{sup -} radiotracer samples with errors lower than 5%. Black-Right-Pointing-Pointer PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S{sup 14}CN{sup -}. Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of {sup 14}C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L{sup -1

  13. Applications of radiotracer techniques for the toxicology studies of nanomaterials

    International Nuclear Information System (INIS)

    Ma Yuhui; Zhang Zhiyong; Zhang Yuan; He Xiao; Zhang Haifeng; Chai Zhifang

    2008-01-01

    With the rapid development of nanosciences and nanotechnology, a wide variety of manufactured nanomaterials are now used in commodities, pharmaceutics, cosmetics, biomedical products, and industries. While nanomaterials possess more novel and unique physicochemical properties than bulk materials, they also have an unpredictable impact on human health. In the toxicology studies of nanomaterials, it is essential to know the basic behaviors in vivo, that is absorption, distribution, metabolism, and excretion (ADME) of these newly designed materials. Radiotracer techniques are especially well suited to such studies and has got the chance to demonstrate its enchantment. In this presentation, studies on radiotracer techniques used in nanotoxicology will be reviewed and new progresses at Institute of High Energy Physics, including the label methods and behaviors of labeled nanomaterials, such as fullerene, carbon nanotubes, and nanometer metal oxide in animals and in aquatic environments will be reported. (authors)

  14. Applications of Beta Particle Detection for Synthesis and Usage of Radiotracers Developed for Positron Emission Tomography

    Science.gov (United States)

    Dooraghi, Alex Abreu

    Positron Emission Tomography (PET) is a noninvasive molecular imaging tool that requires the use of a radioactive compound or radiotracer which targets a molecular pathway of interest. We have developed and employed three beta particle radiation detection systems to advance PET. Specifically, the goals of these systems are to: 1. Automate dispensing of solutions containing a positron emitting isotope. 2. Monitor radioactivity on-chip during synthesis of a positron emitting radiotracer. 3. Assay cellular uptake on-chip of a positron emitting radiotracer. Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing an optimum environment for radiation workers, but also to ensure a quantitatively accurate workflow. For the first project, we describe the development and performance of a system for automated radioactivity distribution of beta particle emitting radioisotopes such as fluorine-18 (F-18). Key to the system is a radiation detector in-line with a peristaltic pump. The system demonstrates volume accuracy within 5 % for volumes of 20 muL or greater. When considering volumes of 20 muL or greater, delivered radioactivity is in agreement with the requested radioactivity as measured with the dose calibrator. The integration of the detector and pump leads to a flexible system that can accurately dispense solutions containing F-18 in radioactivity concentrations directly produced from a cyclotron (~ 0.1-1 mCi/muL), to low activity concentrations intended for preclinical mouse scans (~ 1-10 muCi/muL), and anywhere in between. Electrowetting on dielectric (EWOD) is an attractive microfluidic platform for batch synthesis of PET radiotracers. Visualization of radioisotopes on-chip is critical for synthesis optimization and technological development. For the second project, we describe the development and performance of a Cerenkov/real-time imaging system for PET radiotracer synthesis on EWOD. We also investigate

  15. Development of radiotracer technology and nucleonic control systems - Development of leakage monitoring system using radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Choon; Lee, Doon Sung [Seoil College, Seoul (Korea); Cho, Yong Suk [Konyang University, Nonsan (Korea); Shin, Seung Kwon [Sungkyunkwan University, Seoul (Korea)

    1999-04-01

    This is the equipment to find out the leakage of an oil pipeline and a water pipe reclaimed from the underground, using a Radioisotopes. For this purpose, small sized, light weight and water proofed Detection Pig in high voltage is to be designed and produced as to develope a radiation detector, high voltage power supply circuit, measurement circuit, data storage circuit, and a remote on/off function, etc. In this study, high-voltage producing circuit, an amplifier, count rate circuit, processing circuit, and radiosignal treatment part will be used as a basic material to develope a radiotracer, a radiation measuring and using equipment. And it will promote the localization of the radiation applied measuring system. As the results, domestic equipment industry will be improved a great deal. 22 refs., 22 figs., 8 tabs. (Author)

  16. Ibuprofen induces reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA uptake in severe epithelial breast hyperplasia without atypia.

    Science.gov (United States)

    Papantoniou, Vassilios; Tsaroucha, Angeliki; Valsamaki, Pipitsa; Tsiouris, Spyridon; Sotiropoulou, Evangelia; Karianos, Theodore; Marinopoulos, Spyridon; Fothiadaki, Athina; Sotiropoulou, Maria; Archontaki, Aikaterini; Syrgiannis, Konstantinos; Dimitrakakis, Konstantinos; Antsaklis, Aris

    2010-10-01

    The purpose of this study was to investigate if ibuprofen intake can influence mammary uptake of the proliferation-seeking radiotracer technetium 99m-pentavalent dimercaptosuccinic acid (99mTc-(V)DMSA) in women with severe epithelial and atypical epithelial breast hyperplasia. Eight patients with histologically confirmed severe epithelial breast hyperplasia with (n  =  4) and without atypia (n  =  4) were submitted prospectively to 99mTc-(V)DMSA scintimammography before and after a 4-week course of 400 mg ibuprofen daily oral intake. Lesion to background ratios 60 minutes postinjection were calculated and compared (t-test) before and after ibuprofen administration. Prior to ibuprofen, the patients with severe epithelial hyperplasia displayed a significantly higher 99mTc-(V)DMSA uptake ratio compared to those with atypical epithelial hyperplasia (2.40 ± 0.32 vs 1.67 ± 0.09, respectively; p  =  .003). They also exhibited a more substantial percent decline in tracer uptake postibuprofen compared to women with atypical epithelial hyperplasia (62.0 ± 7.1 vs 15.0 ± 0.2, respectively; p  =  .001). Ibuprofen induces significant uptake reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA in severe epithelial breast hyperplasia without atypia. This agent could therefore constitute a potential imaging tool for monitoring chemoprophylaxis effectiveness in women at the early stages of malignant transformation.

  17. 71Ga-77Se connectivities and proximities in gallium selenide crystal and glass probed by solid-state NMR

    Science.gov (United States)

    Nagashima, Hiroki; Trébosc, Julien; Calvez, Laurent; Pourpoint, Frédérique; Mear, François; Lafon, Olivier; Amoureux, Jean-Paul

    2017-09-01

    We introduce two-dimensional (2D) 71Ga-77Se through-bond and through-space correlation experiments. Such correlations are achieved using (i) the J-mediated Refocused Insensitive Nuclei Enhanced by Polarization Transfer (J-RINEPT) method with 71Ga excitation and 77Se Carr-Purcell-Meiboon-Gill (CPMG) detection, as well as (ii) the J- or dipolar-mediated Hetero-nuclear Multiple-Quantum Correlation (J- or D-HMQC) schemes with 71Ga excitation and quadrupolar CPMG (QCPMG) detection. These methods are applied to the crystalline β-Ga2Se3 and the 0.2Ga2Se3-0.8GeSe2 glass. Such glass leads to a homogeneous and reproducible glass-ceramic, which is a good alternative to single-crystalline Ge and polycrystalline ZnSe materials for making lenses transparent in the IR range for thermal imaging applications. We show that 2D 71Ga-77Se correlation experiments allow resolving the 77Se signals of molecular units, which are not resolved in the 1D 77Se CPMG spectrum. Additionally, the build-up curves of the J-RINEPT and the J-HMQC experiments allow the estimate of the 71Ga-77Se J-couplings via one and three-bonds in the three-dimensional network of β-Ga2Se3. Furthermore, these build-up curves show that the one-bond 1J71Ga-77Se couplings in the 0.2Ga2Se3-0.8GeSe2 glass are similar to those measured for β-Ga2Se3. We also report 2D 71Ga Satellite Transition Magic-Angle Spinning (STMAS) spectrum of β-Ga2Se3 using QCPMG detection at high magnetic field and high Magic-Angle Spinning frequency using large radio frequency field. Such spectrum allows separating the signal of β-Ga2Se3 and that of an impurity.

  18. Diffusion Mechanisms and Lattice Locations of Thermal-Equilibrium Defects in Si-Ge Alloys

    CERN Multimedia

    Lyutovich, K; Touboltsev, V; Laitinen, P O; Strohm, A

    2002-01-01

    It is generally accepted that Ge and Si differ considerably with respect to intrinsic-point-defect-mediated diffusion. In Ge, the native point defects dominating under thermal-equilibium conditions at all solid-state temperatures accessible in diffusion experiments are vacancies, and therefore Ge self-diffusion is vacancy-controlled. In Si, by contrast, self-interstitials and vacancies co-exist in thermal equilibrium. Whereas in the most thoroughly investigated temperature regime above about 1000$^\\circ$C Si self-diffusion is self-interstitial-controlled, it is vacancy-controlled at lower temperatures. According to the scenario displayed above, self-diffusion in Si-Ge alloys is expected to change from an interstitialcy mechanism on the Si side to a vacancy mechanism on the Ge side. Therefore, $^{71}$Ge self-diffusion experiments in Si$_{1- \\it y}$Ge$_{\\it y}$ as a function of composition Y are highly interesting. In a first series of experiments the diffusion of Ge in 0.4 to 10 $\\mu$m thick, relaxed, low-disl...

  19. Combination of sealed source and radiotracer technique to understand malfunctioning in a chemical plant

    Energy Technology Data Exchange (ETDEWEB)

    Yelgaonkar, V.N. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)], E-mail: vivekyel@rediffmail.com; Jayakumar, T.K.; Singh, Sudhir; Sharma, M.K. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)

    2009-07-15

    Pure terphthalic acid (PTA) is produced by the oxidation of paraxylene in an oxidation reactor of a PTA plant. Since the reaction is exothermic, the temperature rises above 210 deg. C. Vapours formed in the reactor are passed through a series of heat exchangers and the cooled liquid is fed back to the reactor, which flows to the reactor by gravity. In one of the heat exchangers, improper flow distribution in the inlet and outlet pipelines was suspected. Maldistribution of flow in the heat exchanger was also suspected. Gamma scanning of the pipelines and a radiotracer experiment were carried out in the heat exchanger to study the malfunctioning. A specially fabricated pipe scanner was used to scan both 24 in diameter and 16 in diameter pipelines. From gamma scanning of the pipelines mostly on the bends, absence of the full bore flow of the liquid was observed. Presence of vapours along with the liquid could be obstructing the liquid flow, thereby causing the malfunctioning. A radiotracer experiment was also carried out to study the flow pattern in the heat exchanger. From the experiment, mean residence time of the heat exchanger was estimated as 470 s, which theoretically should be about 102 s. It indicated that the flow is decelerated in the heat exchanger because of the presence of vapour lock in the tube side.

  20. Search for the production of charged Higgs and technipions with large hadronic branching ratios in e+e- annihilation at 34.5 GeV center of mass energy

    International Nuclear Information System (INIS)

    Barklow, T.L.

    1983-01-01

    A search for the production of charged Higgs and technipions was performed with the TASSO detector at the PETRO e + e - storage ring. These charged scalar particles were assumed to be pair-produced via the pointlike coupling of their charges to the annihilation photon. A four jet analysis technique was used to search specifically for events in which each particle decayed into two jets of hadrons. No evidence for such events was found in 71.5 pb -1 of data at 34.5 GeV center of mass energy. When combined with the results of searches for other charged scalar decay modes, this search excluded all charged scalars with masses between 5 GeV and 13 GeV at the 95% confidence level. The result creates a serious problem for current extended technicolor theories

  1. Challenges in the development of dopamine D2- and D3-selective radiotracers for PET imaging studies.

    Science.gov (United States)

    Mach, Robert H; Luedtke, Robert R

    2018-03-01

    The dopamine D2-like receptors (ie, D2/3 receptors) have been the most extensively studied CNS receptor with Positron Emission Tomography (PET). The 3 different radiotracers that have been used in these studies are [ 11 C]raclopride, [ 18 F]fallypride, and [ 11 C]PHNO. Because these radiotracers have a high affinity for both dopamine D2 and D3 receptors, the density of dopamine receptors in the CNS is reported as the D2/3 binding potential, which reflects a measure of the density of both receptor subtypes. Although the development of D2- and D3-selective PET radiotracers has been an active area of research for many years, this by and large presents an unmet need in the area of translational PET imaging studies. This article discusses some of the challenges that have inhibited progress in this area of research and the current status of the development of subtype selective radiotracers for imaging D3 and D2 dopamine receptors with PET. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Mechanism of action in VIVO of some pet radiotracers

    International Nuclear Information System (INIS)

    Sachinidis, J.J.; Egan, G.F.; Berlangieri, S.U.; Scott, A.M.

    1998-01-01

    Full text: Position Emission Tomography (PET) is a technique that utilises position-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. PET studies range from standard image displays that provide indices of physiological function to complex kinetic analysis methods for absolute quantification. This paper will review some of the important PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre, Melbourne and discuss their mechanism of action in vivo. Depending on their mechanism of action, PET radiopharmaceuticals may be divided into two categories. The first category is non-specific radiotracers which follow a biochemical pathway. The second category is specific radioligands which are involved in an interaction with a receptor transporter or a receptor site. Radiopharmaceuticals from the first category may be assessed using a single or two compartmental plasma-tissue model and allow a measurement of tissue extraction or metabolism.[ 15 O] water is a freely diffusable inert which is used for cerebral blood flow measurement; [ 18 F] FDG which follows the initial phases of glucose metabolism but does not enter the Krebs cycle after phosphorylation and therefore is effectively trapped in the cells, can be used for tissue glucose metabolism measurement in oncology, cardiology and neurology; and [ 18 F]fluoromisonidazole which is a bio-reductive drug that in vivo follows an intracellular reduction pathway, can be used for hypoxic tissue measurement in stroke and tumour evaluation. Radiopharmaceuticals from the second category may be assessed using a three-compartment model: - unmetabolised free ligand in plasma, - free ligand in tissue, - and specially bound ligand in tissue. These radiotracers such as [ 11 C] flumazenil, which is an antagonist with high affinity and selectivity for a central benzodiazepine receptors, are used to study the changes in density or affinity of these receptors

  3. Application of 99mTc-DTPA Radiotracer in Persian Cat's Renal ...

    African Journals Online (AJOL)

    Keywords: Kidney, Persian cat, Radiotracer, Scintigraphy, Technetium-99m diethylene triamine pentacaetic acid ... tracer can be detected in the body by medical equipment .... studies, such as kidney failure, allergic reactions and fatal side ...

  4. Radiotracer technique to predict irritation potential of soap

    International Nuclear Information System (INIS)

    Castaneda, S.S.; Garcia, T.Y.; Santos, F.L.

    1990-01-01

    The application of a radiotracer technique using tritiated water to predict the irritation potentials of some soap products is demonstrated. Collagen films are treated with 0.5% and 1.0% soap solutions and tritiated water then incubated at 50 degrees centigrade for 24 hours. After incubation, the uptake of tritiated water by the collagen films was measured by liquid scintillation counting. (Auth.). 6 refs., 2 tabs

  5. Purification and characterization of enterovirus 71 viral particles produced from vero cells grown in a serum-free microcarrier bioreactor system.

    Directory of Open Access Journals (Sweden)

    Chia-Chyi Liu

    Full Text Available BACKGROUND: Enterovirus 71 (EV71 infections manifest most commonly as a childhood exanthema known as hand-foot-and-mouth disease (HFMD and can cause neurological disease during acute infection. PRINCIPAL FINDING: In this study, we describe the production, purification and characterization of EV71 virus produced from Vero cells grown in a five-liter serum-free bioreactor system containing 5 g/L Cytodex 1 microcarrier. The viral titer was >10(6 TCID(50/mL by 6 days post infection when a MOI of 10(-5 was used at the initial infection. Two EV71 virus fractions were separated and detected when the harvested EV71 virus concentrate was purified by sucrose gradient zonal ultracentrifugation. The EV71 viral particles detected in the 24-28% sucrose fractions had an icosahedral structure 30-31 nm in diameter and had low viral infectivity and RNA content. Three major viral proteins (VP0, VP1 and VP3 were observed by SDS-PAGE. The EV71 viral particles detected in the fractions containing 35-38% sucrose were 33-35 nm in size, had high viral infectivity and RNA content, and were composed of four viral proteins (VP1, VP2, VP3 and VP4, as shown by SDS-PAGE analyses. The two virus fractions were formalin-inactivated and induced high virus neutralizing antibody responses in mouse immunogenicity studies. Both mouse antisera recognized the immunodominant linear neutralization epitope of VP1 (residues 211-225. CONCLUSION: These results provide important information for cell-based EV71 vaccine development, particularly for the preparation of working standards for viral antigen quantification.

  6. Large-angle production of charged pions by 3 GeV/c - 12 GeV/c protons on carbon, copper and tin targets

    CERN Document Server

    Catanesi, M.G.; Ellis, Malcolm; Robbins, S.; Soler, F.J.P.; Gossling, C.; Bunyatov, S.; Krasnoperov, A.; Popov, B.; Serdiouk, V.; Tereschenko, V.; Di Capua, E.; Vidal-Sitjes, G.; Artamonov, A.; Arce, P.; Giani, S.; Gilardoni, S.; Gorbunov, P.; Grant, A.; Grossheim, A.; Gruber, P.; Ivanchenko, V.; Kayis-Topaksu, A.; Panman, J.; Papadopoulos, I.; Pasternak, J.; Tcherniaev, E.; Tsukerman, I.; Veenhof, R.; Wiebusch, C.; Zucchelli, P.; Blondel, A.; Borghi, S.; Campanelli, M.; Morone, M.C.; Prior, G.; Schroeter, R.; Engel, R.; Meurer, C.; Kato, I.; Gastaldi, U.; Mills, G.B.; Graulich, J.S.; Gregoire, G.; Bonesini, M.; Ferri, F.; Paganoni, M.; Paleari, F.; Kirsanov, M.; Bagulya, A.; Grichine, V.; Polukhina, M.; Palladino, V.; Coney, L.; Schmitz, D.; Barr, G.; De Santo, A.; Pattison, C.; Zuber, K.; Bobisut, F.; Gibin, D.; Guglielmi, A.; Mezzetto, M.; Dumarchez, J.; Vannucci, F.; Dore, U.; Orestano, D.; Pastore, F.; Tonazzo, A.; Tortora, L.; Booth, C.; Buttar, C.; Hodgson, P.; howlett, L.; Bogomilov, M.; Chizhov, M.; Kolev, D.; Tsenov, R.; Piperov, Stefan; Temnikov, P.; Apollonio, M.; Chimenti, P.; Giannini, G.; Santin, G.; Burguet-Castell, J.; Cervera-Villanueva, A.; Gomez-Cadenas, J.J.; Martin-Albo, J.; Novella, P.; Sorel, M.; Tornero, A.

    2008-01-01

    A measurement of the double-differential $\\pi^{\\pm}$ production cross-section in proton--carbon, proton--copper and proton--tin collisions in the range of pion momentum $100 \\MeVc \\leq p < 800 \\MeVc$ and angle $0.35 \\rad \\le \\theta <2.15 \\rad$ is presented. The data were taken with the HARP detector in the T9 beam line of the CERN PS. The pions were produced by proton beams in a momentum range from 3 \\GeVc to 12 \\GeVc hitting a target with a thickness of 5% of a nuclear interaction length. The tracking and identification of the produced particles was done using a small-radius cylindrical time projection chamber (TPC) placed in a solenoidal magnet. An elaborate system of detectors in the beam line ensured the identification of the incident particles. Results are shown for the double-differential cross-sections at four incident proton beam momenta (3 \\GeVc, 5 \\GeVc, 8 \\GeVc and 12 \\GeVc).

  7. Impurity analysis in EC-99mTC radiotracer using chromatographic techniques

    International Nuclear Information System (INIS)

    Almeida, E.V.; Fukumori, N.T.O.; Mengatti, J.; Silva, C.P.G.; Matsuda, M.M.N.

    2008-01-01

    The objective of this study was to develop two chromatographic methods of impurity analysis in radiotracer 99m Tc-EC: the Thin Layer Chromatography (TLC) and the High Performance Liquid Chromatography Reversed Phase (HPLC-RP)

  8. Synthesis and marking with technetium and rhenium of a new radiotracer from para-toluidine

    International Nuclear Information System (INIS)

    Laouini, Emna

    2011-01-01

    The development of nuclear medicine is based on the research of new radiotracers especially those which target the neuro degenerative diseases. In fact, the precocious diagnostic of these diseases using the radiopharmaceuticals is the only mean to defeat it. The biodistribution of a new cytectrene derivative from para-toluidine, having a lipophilic character and a low molecular weight, showed a new radiotracer which is able to clear the blood brain barrier and characterised with prolonged brain retention. The features of this complex contribute to make it a radiopharmaceutical to diagnostic aim in clinical use.

  9. SPECT imaging with the serotonin transporter radiotracer [{sup 123}I]p ZIENT in nonhuman primate brain

    Energy Technology Data Exchange (ETDEWEB)

    Cosgrove, Kelly P., E-mail: kelly.cosgrove@yale.ed [Yale University School of Medicine, VA Connecticut HCS (116A6), West Haven, CT 06516 (United States); Staley, Julie K.; Baldwin, Ronald M.; Bois, Frederic [Yale University School of Medicine, VA Connecticut HCS (116A6), West Haven, CT 06516 (United States); Plisson, Christophe [Emory University School of Medicine, Atlanta, GA 30322 (United States); Al-Tikriti, Mohammed S. [Yale University School of Medicine, VA Connecticut HCS (116A6), West Haven, CT 06516 (United States); Seibyl, John P. [Institute for Neurodegenerative Disorders, New Haven, CT 06510 (United States); Goodman, Mark M. [Emory University School of Medicine, Atlanta, GA 30322 (United States); Tamagnan, Gilles D. [Yale University School of Medicine, VA Connecticut HCS (116A6), West Haven, CT 06516 (United States); Institute for Neurodegenerative Disorders, New Haven, CT 06510 (United States)

    2010-07-15

    Introduction: Serotonin dysfunction has been linked to a variety of psychiatric diseases; however, an adequate SPECT radioligand to probe the serotonin transporter system has not been successfully developed. The purpose of this study was to characterize and determine the in vivo selectivity of iodine-123-labeled 2{beta}-carbomethoxy-3{beta}-(4'-((Z)-2-iodoethenyl)phenyl)nortropane, [{sup 123}I]p ZIENT, in nonhuman primate brain. Methods: Two ovariohysterectomized female baboons participated in nine studies (one bolus and eight bolus to constant infusion at a ratio of 9.0 h) to evaluate [{sup 123}I]p ZIENT. To evaluate the selectivity of [{sup 123}I]p ZIENT, the serotonin transporter blockers fenfluramine (1.5, 2.5 mg/kg) and citalopram (5 mg/kg), the dopamine transporter blocker methylphenidate (0.5 mg/kg) and the norepinephrine transporter blocker nisoxetine (1 mg/kg) were given at 8 h post-radiotracer injection. Results: In the bolus to constant infusion studies, equilibrium was established by 4-8 h. [{sup 123}I]p ZIENT was 93% and 90% protein bound in the two baboons and there was no detection of lipophilic radiolabeled metabolites entering the brain. In the high-density serotonin transporter regions (diencephalon and brainstem), fenfluramine and citalopram resulted in 35-71% and 129-151% displacement, respectively, whereas methylphenidate and nisoxetine did not produce significant changes (<10%). Conclusion: These findings suggest that [{sup 123}I]p ZIENT is a favorable compound for in vivo SPECT imaging of serotonin transporters with negligible binding to norepinephrine and dopamine transporters.

  10. The study on Ge-68 production

    International Nuclear Information System (INIS)

    Yang, Seung Dae; Kim, Sang Wook; Hur, Min Goo

    2009-06-01

    The Ge-68 is a correction source of PET and is used in radiopharmaceuticals synthesis. This project is mainly aimed to produce the Ge-68. Based on this project results, the local Ge-68 production can be possible and the revitalization of the radioisotope utilization research areas can be accomplished. The characteristics of the Ge-68 and Ga-68 are obtained and analyzed. The production conditions are also developed, and the domestic and overseas status of the art are considered. The stacked foil target is designed using Al disc and dried Ga 2 O 3 powder, and the irradiation target is also designed. The cross section of the nat. Ga(p,xn) 68 Ge reaction is obtained using the developed target. The separation experiment of cold Ge/Ga in the H 2 SO 4 -HCl solution are carried out as a simulation experiment of the radioactive Ge/Ga sources. The separation of Ge/Ga by liquid extraction of CCl 4 in 8M HCl is also accomplished. And the synthesis experiment of the Hematophorphyrin-Ga complex is performed

  11. Synthesis of a new technetium brain radiotracer

    International Nuclear Information System (INIS)

    El Aissi, Radhia

    2009-01-01

    The radiological diagnosis of brain diseases, including neurodegenerative ones, is still difficult because of the absence of specific biological markers. These diseases are then increasingly the subject of researches and new experiments. The biodistribution of a new cytectrenes-aniline derivative, having a lipophilic character and low molecular weight, showed a prolonged brain retention and a specific tissue distribution of the hippocampus. This radiotracer could contribute to establish early diagnosis of neurodegenerative diseases thanks to its affinity with a serotonin receptors-rich region. (Author)

  12. Increased bone radiotracer uptake in renal osteodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    de Graaf, P.; Schicht, I.M.; de Graeff, J.; te Velde, J.; Kleiverda, K.; Pauwels, E.K.J.

    1982-04-01

    Bone radiotracer uptake in renal osteodystrophy was investigated in 35 dialysis patients by correlating the results of quantitative bone scintigraphy with those of biochemical and bone morphometric studies. There were highly significant correlations (P < 0.001) between the total skeletal activity and the biochemical (iPTH and alkaline phosphatase), and histologic parameters of hyperparathyroidism. These clinical results strongly suggest that increased bone turnover i.e. hyperparathyroidism, rather than osteomalacia is the major cause of increased skeletal uptake in renal osteodystrophy.

  13. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M., E-mail: anacamiqui@gmail.com, E-mail: egoncalves@con.ufrj.br, E-mail: brandao@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  14. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    International Nuclear Information System (INIS)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M.

    2017-01-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  15. Studies on the preparation of {sup 68}Ge-{sup 68}Ga generator with inorganic materials

    Energy Technology Data Exchange (ETDEWEB)

    Brambilla, Tania P.; Osso Junior, Joao A., E-mail: jaosso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    {sup 68}Ga as a positron emitter is of great interest because of some important advantages. It has a physical half-life of 67.71 min, which is compatible with the pharmacokinetics of many radiopharmaceuticals of low molecular weight. Other important characteristic is its cyclotron-independent availability via the {sup 68}Ge-{sup 68}Ga radionuclide generator system. In Brazil only one positron emitter radionuclide is produced, {sup 18}F, and the medical class has a great interest in using {sup 68}Ga labeled molecules, in particular peptides such as DOTA-octriotide. A project for developing a home made {sup 68}Ge-{sup 68}Ga is under way at IPEN-CNEN/SP. The aim of this work is to develop an efficient and simplified generator system of {sup 68}Ge-{sup 68}Ga that offers {sup 68}Ga{sup 3+} adequate for clinical use. Initial results will be reported concerning the behavior of Ge and Ga in adsorbers such as calcined acid and basic Al{sub 2}O{sub 3}, HZO (hydrous zirconium oxide), TiO{sub 2}, microspheres of Zr (Zr mic) and microspheres of Al (Al mic). Adsorption studies were carried out using {gamma}-emitting tracers, {sup 67}Ga and {sup 68}Ga and chemical tracer, GeO{sub 2}. The samples containing {sup 67}/{sup 68}Ga were analysed using a dose calibrator CRC-15R from Capintec and the samples containing Ge were evaluated by the Optical Emission Spectrometry using Inductively Coupled Plasma (ICP-OES). The ICP-OES equipment used was a Varian Vista-MPX from Varian and calibration curves for Ge were constructed in the range of 0.2 to 1.0 {mu}g.mL{sup -1}. The use of basic Al{sub 2}O{sub 3}, TiO{sub 2}, HZO and Zr mic showed the more promising results. (author)

  16. Residence time distribution measurements in a pilot-scale poison tank using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Goswami, Sunil; Samantray, J S; Sharma, V K; Maheshwari, N K

    2015-09-01

    Various types of systems are used to control the reactivity and shutting down of a nuclear reactor during emergency and routine shutdown operations. Injection of boron solution (borated water) into the core of a reactor is one of the commonly used methods during emergency operation. A pilot-scale poison tank was designed and fabricated to simulate injection of boron poison into the core of a reactor along with coolant water. In order to design a full-scale poison tank, it was desired to characterize flow of liquid from the tank. Residence time distribution (RTD) measurement and analysis was adopted to characterize the flow dynamics. Radiotracer technique was applied to measure RTD of aqueous phase in the tank using Bromine-82 as a radiotracer. RTD measurements were carried out with two different modes of operation of the tank and at different flow rates. In Mode-1, the radiotracer was instantaneously injected at the inlet and monitored at the outlet, whereas in Mode-2, the tank was filled with radiotracer and its concentration was measured at the outlet. From the measured RTD curves, mean residence times (MRTs), dead volume and fraction of liquid pumped in with time were determined. The treated RTD curves were modeled using suitable mathematical models. An axial dispersion model with high degree of backmixing was found suitable to describe flow when operated in Mode-1, whereas a tanks-in-series model with backmixing was found suitable to describe flow of the poison in the tank when operated in Mode-2. The results were utilized to scale-up and design a full-scale poison tank for a nuclear reactor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Search for new negative particles produced in 14. 6 A GeV/C Si+A interactions

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, H J; Engelage, J; Greiner, L [Space Sciences Lab., Univ. of California, Berkeley (United States); Aoki, M; Hayano, R S; Shimizu, Y [Univ. of Tokyo (Japan); Beatty, J [Boston Univ., MA (United States); Beavis, D; Debbe, R [Brookhaven National Lab., Upton, NY (United States); Carroll, J B [Univ. of California, Los Angeles (United States); Chiba, J; Tanaka, K H [National Lab. for High Energy Physics (KEK), Tsukuba (Japan); Doke, T; Kashiwagi, T; Kikuchi, J [Waseda Univ., Tokyo (Japan); Hallman, T J [Johns Hopkins Univ., Baltimore, MD (United States); Heckman, H; Lindstrom, P J [Lawrence Berkeley Lab., CA (United States); Kirk, P N; Wang, Z F [Louisiana State Univ., Baton Rouge (United States); Nagamiya, S; Stankus, P [Columbia Univ., Nevis Lab., Irvington, NY (United States)

    1991-12-01

    We discuss an investigation of negative particle production in interactions of 14.6 A GeV/c {sup 28}Si with targets of Al, Cu, and Au at the Brookhaven National Laboratory AGS, experiment E858. The experiment was performed using a beamline spectrometer to measure cross sections for meta-stable negatively charged particles produced at 0deg at rigidities from 2 GV to 8 GV. We report upper limits on the production of new particles in the mass to charge (A/Z) range from -1 to -6 and discuss a simple model for describing our sensitivity. (orig.).

  18. Determination of a new structure type in the Sc-Fe-Ge-Sn system

    Energy Technology Data Exchange (ETDEWEB)

    Brgoch, Jakoah [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ran, Sheng [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Thimmaiah, Srinivasa [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Canfield, Paul C. [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Miller, Gordon J., E-mail: gmiller@iastate.edu [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States)

    2013-01-05

    Highlights: Black-Right-Pointing-Pointer A new structure type with the composition Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)}. Black-Right-Pointing-Pointer Crystallizes in the space group Immm (No. 71, oI144). Black-Right-Pointing-Pointer Sample obtained using a reactive Sn flux. Black-Right-Pointing-Pointer Electronic structure calculations indicate polar intermetallic bonding network. - Abstract: A new structure type has been discovered in the system Sc-Fe-Ge-Sn by employing Sn as a flux medium. According to single crystal X-ray diffraction, the new structure has a composition of Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)} and crystallizes in the space group Immm (No. 71, oI144) with lattice parameters of a = 5.230(1) A, b = 13.467(3) A, and c = 30.003(6) A. The structure is composed of square anti-prismatic clusters that are condensed into zig-zag chains along the [0 1 0] direction. These chains are further condensed through a split Sn/Ge position, forming a three-dimensional network. Magnetization measurements indicate an antiferromagnetic phase transition near 240 K. Electronic structure calculations identified the most favorable bonding network in this new system. Using crystal orbital Hamilton population (COHP) curves and their integrated values (ICOHP), a polar intermetallic bonding network involving Sc-Ge as well as Fe-Sn and Fe-Ge contacts can be assigned to this new structure type.

  19. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, J.; Flores Juan, P.; Cuesta Borges, J.; Damera Martinez, A.; Ramos Espinosa, K. A

    2005-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one with Low Residence Time (BTR), both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented. Several trials performed at the two Clarifiers demonstrated that the one identified as BTR was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The radiotracer method was able to detect certain differences between the two clear juice outlet of the BTR Clarifier, probably due some problems in the construction of this equipment

  20. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  1. Radiotracer technology as applied to industry. Final report of a co-ordinated research project 1997-2000

    International Nuclear Information System (INIS)

    2001-12-01

    The Co-ordinated Research Project (CRP) on Radiotracer Technology for Engineering Unit Operation Studies and Unit Process Optimization was carried out by the International Atomic Energy Agency (IAEA) from December 1997 until December 2000. The project developed and validated procedures and protocols for investigation of major industrial processes, including fluidized beds, sugar crystallizers, trickle bed reactors, cement rotary kilns, flotation cells, grinding mills, incinerators, wastewater treatment units and interwell communications in oil fields. This publication is the output of the above mentioned CRP. It provides the principles and state of the art of radiotracer methodology and technology as applied to industry and environment. It is expected to provide wider interest for further development of skills and confidence prior to carrying out field work. It facilitates transfer of technology from developed to developing countries and from nuclear research institutions to industrial end users. The publication could be a suitable guide for radiotracer applications in almost all types of process investigations. The case studies described in this publication deal with typical problems in industry and environment common to all countries. It is intended for radiotracer groups as well as for end engineers and managers from chemical and petrochemical industries, mineral ore and raw material processing, wastewater treatment plants, and other industrial sectors

  2. GeO2/Ge structure submitted to annealing in deuterium: Incorporation pathways and associated oxide modifications

    Science.gov (United States)

    Bom, N. M.; Soares, G. V.; Hartmann, S.; Bordin, A.; Radtke, C.

    2014-10-01

    Deuterium (D) incorporation in GeO2/Ge structures following D2 annealing was investigated. Higher D concentrations were obtained for GeO2/Ge samples in comparison to their SiO2/Si counterparts annealed in the same conditions. Oxygen vacancies produced during the annealing step in D2 constitute defect sites for D incorporation, analogous to defects at the SiO2/Si interfacial region. Besides D incorporation, volatilization of the oxide layer is also observed as a consequence of D2 annealing, especially in the high temperature regime of the present study (>450 °C). In parallel to this volatilization, the stoichiometry and chemical structure of remnant oxide are modified as well. These results evidence the broader impact of forming gas annealing in dielectric/Ge structures with respect to SiO2/Si counterparts.

  3. Estimation of shell thickness in a continuously cast steel billet using radiotracers

    International Nuclear Information System (INIS)

    Prasad, A.S.; Pandey, J.C.; Kaur, G.

    1994-01-01

    In the continuous casting of steel, one of the factors which limits the rate of faster withdrawal of the casting from the mould is the thickness of the solid shell below the mould. If the shell can not contain the liquid pool, breakouts occur and process of casting disrupts. Estimates of shell thickness have been made on the basis of heat- transfer considerations. The shell thickness could also be delineated, to some extent, by adding radiotracers during casting and subsequently determining the dispersion of radioactivity by autoradiography. The paper presents the results of the estimation of shell thickness based on the heat-transfer model and validation of the model by plant trials using radiotracers. (author). 11 refs., 5 figs., 1 tab

  4. The 76Ge(n,p)76Ga reaction and its relevance to searches for the neutrino-less double-beta decay of 76Ge

    Science.gov (United States)

    Tornow, W.; Bhike, Megha; Fallin, B.; Krishichayan, Fnu

    2015-10-01

    The 76Ge(n,p)76Ga reaction and the subsequent β decay of 76Ga to 76Ge has been used to excite the 3951.9 keV state of 76Ge, which decays by emission of a 2040.7 keV γ ray. Using HPGe detectors, the associated pulse-height signal may be undistinguishable from the potential signal produced in neutrino-less double-beta decay of 76Ge with its Q-value of 2039.0 keV. In the neutron energy range between 10 and 20 MeV the production cross section of the 2040.7 keV γ ray is approximately 0.1 mb. In the same experiment γ rays of energy 2037.9 keV resulting from the 76Ge(n, γ)77Ge reaction were clearly observed. Adding the 76Ge(n,n' γ)76Ge reaction, which also produces the 2040.7 keV γ ray with a cross section value of the order of 0.1 mb clearly shows that great care has to be taken to eliminate neutron-induced backgrounds in searches for neutrino-less double-beta decay of 76Ge. This work was supported by the U.S. DOE under Grant NO. DE-FG02-97ER41033.

  5. Development of a production scale purification of Ge-68 from irradiated gallium metal

    Energy Technology Data Exchange (ETDEWEB)

    Fitzsimmons, Jonathan M.; Mausner, Leonard [Brookhaven National Laboratory, Upton, NY (United States)

    2015-05-01

    Germanium-68 (Ge-68) is produced by proton irradiation of a gallium metal target and purified by organic extraction. The Ge-68 can be used in a medical isotope generator to produce Gallium-68 (Ga-68) which can be used to radiolabel PET imaging agents. The emerging use of Ge-68 in the Ga-68 medical isotope generator has caused us to develop a new purification method for Ge-68 that does not use toxic solvents. The purpose of this work was to develop a production scale separation of Ge-68 that utilizes a leaching step to remove a bulk of the gallium metal, followed by purification with Sephadex {sup copyright} G25. Production scale (300 mCi) purification was performed with the new method. The purified Ge-68 contained the highest radioactivity concentration of Ge-68 produced at BNL; the sample meet Department of Energy specifications and the method had an excellent recovery of Ge-68.

  6. Investigation of flow behaviour of coal particles in a pilot-scale fluidized bed gasifier (FBG) using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Kamudu, M Vidya; Prakash, S G; Krishanamoorthy, S; Anandam, G; Rao, P Seshubabu; Ramani, N V S; Singh, Gursharan; Sonde, R R

    2009-09-01

    Knowledge of residence time distribution (RTD), mean residence time (MRT) and degree of axial mixing of solid phase is required for efficient operation of coal gasification process. Radiotracer technique was used to measure the RTD of coal particles in a pilot-scale fluidized bed gasifier (FBG). Two different radiotracers i.e. lanthanum-140 and gold-198 labeled coal particles (100 gm) were independently used as radiotracers. The radiotracer was instantaneously injected into the coal feed line and monitored at the ash extraction line at the bottom and gas outlet at the top of the gasifier using collimated scintillation detectors. The measured RTD data were treated and MRTs of coal/ash particles were determined. The treated data were simulated using tanks-in-series model. The simulation of RTD data indicated good degree of mixing with small fraction of the feed material bypassing/short-circuiting from the bottom of the gasifier. The results of the investigation were found useful for optimizing the design and operation of the FBG, and scale-up of the gasification process.

  7. Radiotracers for PETT: new developments and perspectives

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references

  8. Radiotracer design strategies for neurocardiology

    International Nuclear Information System (INIS)

    Wieland, D.M.; Hutchins, G.D.

    1991-01-01

    Nuclear cardiologists have expended an inordinate amount of effort studying the open-quotes plumbingclose quotes of the heart but very little effort on the open-quotes wiringclose quotes. L. Rossi declared in 1988, open-quotes today's desultory information about basic changes in the heart's innervation, if compared with current knowledge about diseases of cardiac muscle and vessels, is largely attributable to an aura of forbidding technical difficulty.close-quote During the past three years, radiotracers have been developed for use in studies of cardiac nerve function by positron emission tomography (PET). The first clinical PET studies in this area were reported in 1990. This chapter discusses the strategies that led to the tracers presently available and the possible nature of future neuronal markers

  9. Measurements of neutron spectra produced from a thick tungsten target bombarded with 0.5- and 1.5-GeV protons

    International Nuclear Information System (INIS)

    Meigo, Shin-ichiro; Takada, Hiroshi

    2002-01-01

    For validation of calculation codes that are employed in the design of pulse spallation neutron source and accelerator driven system, spectrum of neutrons produced from a thick target plays an important role. However, appropriate experimental data were scarce for the incident energies higher than 0.8 GeV. In this study, the spectrum from a thick tungsten target was measured. The experiment was carried out at the π2 beam line of the 12-GeV proton synchrotron at KEK. The tungsten target was bombarded by the 0.5- and 1.5-GeV secondary protons. Spectrum of neutrons was measured by the time-of-flight technique using organic scintillators of NE213. The calculated result with NMTC/JAM and MCNP-4A is compared with the measured data. It is found that the NMTC/JAM generally gives a good agreement with experiment. The NMTC/JAM, however, gives 50% lower neutron flux in the energy region 20∼80 MeV, which is consistent with the results in previous comparison of lead target. For the neutrons between 20 and 80 MeV, the calculation using with the in-medium nucleon-nucleon cross sections reproduced the experiment fairly well. (author)

  10. Structural and phonon transmission study of Ge-Au-Ge eutectically bonded interfaces

    International Nuclear Information System (INIS)

    Knowlton, W.B.; Lawrence Berkeley Lab., CA

    1995-07-01

    This thesis presents a structural analysis and phonon transparency investigation of the Ge-Au-Ge eutectic bond interface. Interface development was intended to maximize the interfacial ballistic phonon transparency to enhance the detection of the dark matter candidate WIMPs. The process which was developed provides an interface which produces minimal stress, low amounts of impurities, and insures Ge lattice continuity through the interface. For initial Au thicknesses of greater than 1,000 angstrom Au per substrate side, eutectic epitaxial growth resulted in a Au dendritic structure with 95% cross sectional and 90% planar Au interfacial area coverages. In sections in which Ge bridged the interface, lattice continuity across the interface was apparent. Epitaxial solidification of the eutectic interface with initial Au thicknesses < 500 A per substrate side produced Au agglomerations thereby reducing the Au planar interfacial area coverage to as little as 30%. The mechanism for Au coalescence was attributed to lateral diffusion of Ge and Au in the liquid phase during solidification. Phonon transmission studies were performed on eutectic interfaces with initial Au thicknesses of 1,000 angstrom, 500 angstrom, and 300 angstrom per substrate side. Phonon imaging of eutectically bonded samples with initial Au thicknesses of 300 angstrom/side revealed reproducible interfacial percent phonon transmissions from 60% to 70%. Line scan phonon imaging verified the results. Phonon propagation TOF spectra distinctly showed the predominant phonon propagation mode was ballistic. This was substantiated by phonon focusing effects apparent in the phonon imaging data. The degree of interface transparency to phonons and resulting phonon propagation modes correlate with the structure of the interface following eutectic solidification. Structural studies of samples with initial Au thickness of 1,000 angstrom/side appear to correspond with the phonon transmission study

  11. Structural and phonon transmission study of Ge-Au-Ge eutectically bonded interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Knowlton, W.B. [Univ. of California, Berkeley, CA (United States). Dept. of Materials Science and Mineral Engineering]|[Lawrence Berkeley Lab., CA (United States). Materials Sciences Div.

    1995-07-01

    This thesis presents a structural analysis and phonon transparency investigation of the Ge-Au-Ge eutectic bond interface. Interface development was intended to maximize the interfacial ballistic phonon transparency to enhance the detection of the dark matter candidate WIMPs. The process which was developed provides an interface which produces minimal stress, low amounts of impurities, and insures Ge lattice continuity through the interface. For initial Au thicknesses of greater than 1,000 {angstrom} Au per substrate side, eutectic epitaxial growth resulted in a Au dendritic structure with 95% cross sectional and 90% planar Au interfacial area coverages. In sections in which Ge bridged the interface, lattice continuity across the interface was apparent. Epitaxial solidification of the eutectic interface with initial Au thicknesses < 500 A per substrate side produced Au agglomerations thereby reducing the Au planar interfacial area coverage to as little as 30%. The mechanism for Au coalescence was attributed to lateral diffusion of Ge and Au in the liquid phase during solidification. Phonon transmission studies were performed on eutectic interfaces with initial Au thicknesses of 1,000 {angstrom}, 500 {angstrom}, and 300 {angstrom} per substrate side. Phonon imaging of eutectically bonded samples with initial Au thicknesses of 300 {angstrom}/side revealed reproducible interfacial percent phonon transmissions from 60% to 70%. Line scan phonon imaging verified the results. Phonon propagation TOF spectra distinctly showed the predominant phonon propagation mode was ballistic. This was substantiated by phonon focusing effects apparent in the phonon imaging data. The degree of interface transparency to phonons and resulting phonon propagation modes correlate with the structure of the interface following eutectic solidification. Structural studies of samples with initial Au thickness of 1,000 {angstrom}/side appear to correspond with the phonon transmission study.

  12. Development of a system for real-time measurements of metabolite transport in plants using short-lived positron-emitting radiotracers

    Science.gov (United States)

    Kiser, Matthew R.

    Over the past 200 years, the Earth's atmospheric carbon dioxide (CO 2) concentration has increased by more than 35%, and climate experts predict that CO2 levels may double by the end of this century. Understanding the mechanisms of resource management in plants is fundamental for predicting how plants will respond to the increase in atmospheric CO 2. Plant productivity sustains life on Earth and is a principal component of the planet's system that regulates atmospheric CO2 concentration. As such, one of the central goals of plant science is to understand the regulatory mechanisms of plant growth in a changing environment. Short-lived positron-emitting radiotracer techniques provide time-dependent data that are critical for developing models of metabolite transport and resource distribution in plants and their microenvironments. To better understand the effects of environmental changes on resource transport and allocation in plants, we have developed a system for real-time measurements of rnetabolite transport in plants using short-lived positron-emitting radio-tracers. This thesis project includes the design, construction, and demonstration of the capabilities of this system for performing real-time measurements of metabolite transport in plants. The short-lived radiotracer system described in this dissertation takes advantage of the combined capabilities and close proximity of two research facilities at. Duke University: the Triangle Universities Nuclear Laboratory (TUNL) and the Duke University Phytotron, which are separated by approximately 100 meters. The short-lived positron-emitting radioisotopes are generated using the 10-MV tandem Van de Graaff accelerator located in the main TUNL building, which provides the capability of producing short-lived positron-emitting isotopes such as carbon-11 (11C: 20 minute half-life), nitrogen-13 (13N; 10 minute half-life), fluorine-18 (18F; 110 minute half-life), and oxygen-15 (15O; 2 minute half-life). The radioisotopes may

  13. Study of technological parameters influence on homogeneity of rubber mixings by means of radiotracer methods

    International Nuclear Information System (INIS)

    Koczorowska, E.

    1995-01-01

    The radiotracer methods have been worked out for analysis of physico-chemical phenomena. The analysis were carried out for rubber mixings in technological conditions and played a deciding role for quality of manufacturing assortment. The 35 S and 65 Zn have been used as radiotracers. Analysis of different technological parameters influence on behaviour of soluble and polymerized sulfur, zinc compounds as well as other components of the rubber mixing enables to formulate the conclusions important for rubber industry and technology from view point of quality of manufacturing products

  14. The early use of radiotracers in chemistry

    International Nuclear Information System (INIS)

    Grabowski, K.F.M.

    1986-01-01

    This article describes the historical background to the use of radiotracers, pioneered by de Hevesy and Paneth before World War I. It traces their early use in ion and metal interchange in electrolysis, self-diffusion rates, early biochemical experiments on lead uptake in plants, phosphorus metabolism in rats, through to their wider use with the production of artificial radioisotopes after World War II. Photosynthesis experiments using carbon-11 and carbon-14 are described and their present-day widespread use in kinetics, metabolic pathway studies and therapeutics is discussed. (UK)

  15. Radiotracers for PETT: new developments and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references. (PSB)

  16. Study of Ge loss during Ge condensation process

    International Nuclear Information System (INIS)

    Xue, Z.Y.; Di, Z.F.; Ye, L.; Mu, Z.Q.; Chen, D.; Wei, X.; Zhang, M.; Wang, X.

    2014-01-01

    Ge loss during Ge condensation process was investigated by transmission electron microscopy, Raman spectroscopy, secondary ion mass spectrometry and Rutherford backscattering spectrometry. This work reveals that Ge loss can be attributed to the Ge oxidation at SiO 2 /SiGe interface, Ge diffusion in SiO 2 layers and Ge trapped at buried SiO 2 /Si interface. During Ge condensation process, with the increase of the Ge content, the Si atoms become insufficient for selective oxidation at the oxide/SiGe interface. Consequently, the Si and Ge are oxidized simultaneously. When the Ge composition in SiGe layer increases further and approaches 100%, the Ge atoms begin to diffuse into the top SiO 2 layer and buried SiO 2 layer. However, the X-ray photoelectron spectrometry analysis manifests that the chemical states of the Ge in top SiO 2 layer are different from those in buried SiO 2 layer, as the Ge atoms diffused into top SiO 2 layer are oxidized to form GeO 2 in the subsequent oxidation step. With the increase of the diffusion time, a quantity of Ge atoms diffuse through buried SiO 2 layer and pile up at buried SiO 2 /Si interface due to the interfacial trapping. The SiO 2 /Si interface acts like a pump, absorbing Ge from a Ge layer continuously through a pipe-buried SiO 2 layer. With the progress of Ge condensation process, the quantity of Ge accumulated at SiO 2 /Si interface increases remarkably. - Highlights: • Ge loss during Ge condensation process is attributed to the Ge oxidation at SiO 2 /SiGe interface. • Ge diffusion in SiO 2 layers and Ge trapped at buried SiO 2 /Si interface • When Ge content in SiGe layer approaches 100%, Ge diffusion into the SiO 2 layer is observed. • Ge then gradually diffuses through buried SiO 2 layer and pile up at SiO 2 /Si interface

  17. 5-10 GeV neutrinos from gamma-Ray burst fireballs

    Science.gov (United States)

    Bahcall; Meszaros

    2000-08-14

    A gamma-ray burst fireball is likely to contain an admixture of neutrons. Inelastic collisions between differentially streaming protons and neutrons in the fireball produce nu(&mgr;) (nu;(&mgr;)) of approximately 10 GeV as well as nu(e) (nu;(e)) of approximately 5 GeV, which could produce approximately 7 events/year in km(3) detectors, if the neutron abundance is comparable to that of protons. Photons of approximately 10 GeV from pi(0) decay and approximately 100 MeV nu;(e) from neutron decay are also produced, but will be difficult to detect. Photons with energies less, similar1 MeV from shocks following neutron decay produce a characteristic signal which may be distinguishable from the proton-related MeV photons.

  18. Photoluminescence and electroluminescence from Ge/strained GeSn/Ge quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chung-Yi; Chang, Chih-Chiang [Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan (China); Huang, Chih-Hsiung; Huang, Shih-Hsien [Department of Electrical Engineering, Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Liu, C. W., E-mail: chee@cc.ee.ntu.edu.tw [Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan (China); Department of Electrical Engineering, Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan (China); National Nano Device Labs, Hsinchu 30077, Taiwan (China); Huang, Yi-Chiau; Chung, Hua; Chang, Chorng-Ping [Applied Materials Inc., Sunnyvale, California 94085 (United States)

    2016-08-29

    Ge/strained GeSn/Ge quantum wells are grown on a 300 mm Si substrate by chemical vapor deposition. The direct bandgap emission from strained GeSn is observed in the photoluminescence spectra and is enhanced by Al{sub 2}O{sub 3}/SiO{sub 2} passivation due to the field effect. The electroluminescence of the direct bandgap emission of strained GeSn is also observed from the Ni/Al{sub 2}O{sub 3}/GeSn metal-insulator-semiconductor tunneling diodes. Electroluminescence is a good indicator of GeSn material quality, since defects in GeSn layers degrade the electroluminescence intensity significantly. At the accumulation bias, the holes in the Ni gate electrode tunnel to the strained n-type GeSn layer through the ultrathin Al{sub 2}O{sub 3} and recombine radiatively with electrons. The emission wavelength of photoluminescence and electroluminescence can be tuned by the Sn content.

  19. Fluctuations in the size of the largest projectile fragment produced in 1 GeV/nucleon Au + C collisions

    International Nuclear Information System (INIS)

    Warren, P.; Elliott, J.B.; Gilkes, M.L.; Hauger, A.; Hirsch, A.S.

    1993-01-01

    Large fluctuations in quantities such as density are characteristic of critical phenomena in the neighborhood of the critical point. Using the EOS apparatus at the Bevalac, we have performed an exclusive experiment in which the size of the largest projectile fragment produced in 1 GeV/nucleon Au+C collisions is studied as a function of the charged multiplicity of the event. A peak in the fluctuations is expected at the critical multiplicity. The data are compared to a percolation model and a statistical multifragmentation model

  20. Application of analogue computers to radiotracer data processing

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1979-01-01

    Some applications of analogue computers for processing the flow-system radiotracer-investigation data are presented. Analysis of the impulse response shaped to obtain the frequency response of the system under consideration can be performed on the basis of an estimated transfer function. Furthermore, simulation of the system behaviour for other excitation functions is discussed. Simple approach is made for estimating the model parameters in situations where the input signal is not approximated by the unit impulse function. (author)

  1. Preparation of the Nanostructured Radioisotope Metallic Oxide by Neutron Irradiation for Use as Radiotracers

    Directory of Open Access Journals (Sweden)

    Sang-Ei Seo

    2017-10-01

    Full Text Available Metallic oxides manganese dioxide (MnO2, samarium oxide (Sm2O3, and dysprosium oxide (Dy2O3 with nanorod-like structures were synthesized by the hydrothermal synthesis method, respectively. Subsequently, the nanostructured radioisotopes MnO2 with Mn-56, Sm2O3 with Sm-153, and Dy2O3 with Dy-165 were prepared by neutron irradiation from the HANARO research reactor, respectively. The three different elements, Mn, Sm, and Dy, were selected as radiotracers because these elements can be easily gamma-activated from neutrons (activation limits: 1 picogram (Dy, 1–10 picogram (Mn, 10–100 picogram (Sm. Furthermore, the synthesized radioisotopes can be used as radiotracers in Prompt Gamma Neutron Activation Analysis as the rare earth metals Dy and Sm were not present in the Korean environment. The successful synthesis of the radioisotope metallic oxides was confirmed by Transmission Electron Microscopy (TEM, Energy Dispersive X-ray Spectrometry (EDS, X-ray Diffraction (XRD analysis, and gamma spectroscopy analysis. The synthesized nanostructured radioisotope metallic oxides may be used as radiotracers in scientific, environmental, engineering, and industrial fields.

  2. Measurements of Neutron Spectra Produced from a Thick Iron Target Bombarded with 1.5-GeV Protons

    International Nuclear Information System (INIS)

    Meigo, Shin-ichiro; Shigyo, Nobuhiro; Iga, Kiminori; Iwamoto, Yosuke; Kitsuki, Hirohiko; Ishibashi, Kenji; Maehata, Keisuke; Arima, Hidehiko; Nakamoto, Tatsushi; Numajiri, Masaharu

    2005-01-01

    For validation of calculation codes that are employed in the design of accelerator facilities, spectra of neutrons produced from a thick iron target bombarded with 1.5-GeV protons were measured. The calculated results with NMTC/JAM were compared with the present experimental results. It is found that the NMTC/JAM generally shows good agreement with experiment. Furthermore, the calculation gives good agreement with the experiment for the energy region 20 to 80 MeV for iron, whereas the NMTC/JAM gives 50% of the experimental data for the heavy-nuclides such as lead and tungsten

  3. Measurements of neutron spectra produced from a thick iron target bombarded with 1.5 GeV protons

    International Nuclear Information System (INIS)

    Meigo, Shin-ichiro; Takada, Hiroshi

    2001-01-01

    For validation of calculation codes which are employed in the design of accelerator facilities, spectra of neutrons produced from a thick iron target bombarded with 1.5-GeV protons were measured. The calculated results with NMTC/JAM were compared with the present experimental results. It is found the NMTC/JAM generally shows in good agreement with experiment. Furthermore, the calculation gives good agreement with the experiment for the energy region 20-80 MeV, whereas the NMTC/JAM gives 50% of the experimental data for the heavy nuclide target such as lead and tungsten target. (author)

  4. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggests that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  5. Radiotracer studies of fungicide residues in food plants

    International Nuclear Information System (INIS)

    1990-04-01

    Agricultural fungicides are chemicals used on seeds, crops and in soils throughout the growing season. Fungicide treatments may lead to various levels of chemical residues in food commodities. Primary emphasis has been placed on ethylenebisdithiocarbamates (EBDCs), an important group of agrofungicides used in preparations for spraying or dusting major crops such as apples, pears, broccoli, cabbages, egg plants, cauliflower, grapes, lettuce, peppers, celery, cucumbers and tomatoes. Treatments with EBDCs result in terminal residues containing ethylenthiourea (ETU). This is a toxicologically significant decomposition product which has attracted considerable attention in recent years due to indications of its potential goitrogenic and carcinogenic properties. In recognition of the need for a coordinated examination of ETU levels in food, particularly under tropical conditions, the program of radiotracer techniques as a tool for studying fungicide residue problems on food was initiated in 1984. In current studies, three EBDCs, maneb, zineb and mancozeb from different manufacturers in different countries were analysed. This report describes the model protocols (Annexes I, II and III) as they were set up for determination of residues in commodities and soil, using radiotracer and conventional chromatographic techniques . In the 16 papers presented in this report C 14 -labelled EBDCs are determined in plants, vegetables, and soils, before and after cooking, as a function of time and of other agricultural parameters. Refs, figs and tabs

  6. Search for Chargino and Neutralino Production at $\\sqrt{s} = 189 GeV$ at LEP

    CERN Document Server

    Abbiendi, G.; Alexander, G.; Allison, John; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bellerive, A.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bloodworth, I.J.; Bock, P.; Bohme, J.; Boeriu, O.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brigliadori, L.; Brown, Robert M.; Burckhart, H.J.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couchman, J.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Dallison, S.; Davis, R.; De Jong, S.; de Roeck, A.; Dervan, P.; Desch, K.; Dienes, B.; Dixit, M.S.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Estabrooks, P.G.; Etzion, E.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Feld, L.; Ferrari, P.; Fiedler, F.; Fierro, M.; Fleck, I.; Frey, A.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Graham, K.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hajdu, C.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Harder, K.; Harel, A.; Hargrove, C.K.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hobson, P.R.; Hocker, James Andrew; Hoffman, Kara Dion; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klier, A.; Kobayashi, T.; Kobel, M.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kyberd, P.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lauber, J.; Lawson, I.; Layter, J.G.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; Lillich, J.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Lu, J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mader, W.; Mannelli, M.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Merritt, F.S.; Mes, H.; Meyer, I.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Quadt, A.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Rosati, S.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schmitt, S.; Schoning, A.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Spagnolo, S.; Sproston, M.; Stahl, A.; Stephens, K.; Stoll, K.; Strom, David M.; Strohmer, R.; Surrow, B.; Talbot, S.D.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomas, J.; Thomson, M.A.; Torrence, E.; Towers, S.; Trefzger, T.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Voss, H.; Wackerle, F.; Wagner, A.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; Wetterling, D.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Zacek, V.; Zer-Zion, D.

    2000-01-01

    A search for charginos and neutralinos, predicted by supersymmetric theories, is performed using a data sample of 182.1 pb-1 taken at a centre-of-mass energy of 189 GeV with the OPAL detector at LEP. No evidence for chargino or neutralino production is found. Upper limits on chargino and neutralino pair production cross-sections are obtained as a function of the chargino mass, the lightest neutralino mass and the second lightest neutralino mass. Within the Constrained Minimal Supersymmetric Standard Model framework, and for a chargino - neutralino mass difference of more than 5 GeV, the 95% confidence level lower limits on the chargino mass are 93.6 GeV for tan{beta} = 1.5 and 94.1 GeV for tan{beta} = 35. These limits are obtained assuming a universal scalar mass m_0 > 500 GeV. The corresponding limits for all m_0 are 78.0 and 71.7 GeV. The 95% confidence level lower limits on the lightest neutralino mass, valid for any value of tan{beta} are 32.8 GeV for m_0 > 500 GeV and 31.6 GeV for all m_0.

  7. 10 CFR Appendix L to Part 110 - Illustrative List of Byproduct Materials Under NRC Export/Import Licensing Authority a

    Science.gov (United States)

    2010-01-01

    ... material produced, extracted, or converted for use for a commercial, medical, or research activity...) Gallium 72 (Ga 72) Germanium 68 (Ge 68) Germanium 71 (Ge 71) Gold 198 (Au 198) Gold 199 (Au 199) Hafnium...

  8. Flow Rate Measurement Using 99mTc Radiotracer Method in a Pipe Installation

    International Nuclear Information System (INIS)

    Sipaun, S. M.; Bakar, A. Q. Abu; Othman, N.; Shaari, M. R.; Adnan, M. A. K.; Yusof, J. Mohd; Demanah, R.

    2010-01-01

    Flow rate is a significant parameter for managing processes in chemical processing plants and water processing facility. Accurate measurement of the flow rate allows engineers to monitor the delivery of process material, which in turn impacts a plant's capacity to produce their products. One of the available methods for determining the flow rate of a process material is by introducing a radiotracer to the system that mimics the material's flow pattern. In this study, a low activity Technetium-99m radioisotope was injected into a water piping setup and the 2'' x 2'' NaI (Tl) detectors were calibrated to detect spectrum peaks at specific points of the pipe installation. Using pulse velocity method, water flow rate was determined to be 11.3 litres per minute. For the sampling method, at different pump capacity, the flow rate was 15.0 litres per minute.

  9. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer

    International Nuclear Information System (INIS)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W.M.M.; Wiegerinck, Peter H.G.; Pietzsch, Jens; Bergmann, Ralf

    2009-01-01

    The radiosynthesis of [N-methyl- 11 C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [ 11 C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23±5% (decay-corrected, based upon [ 11 C]CO 2 ) at a specific activity of 47±12 GBq/μmol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl- 11 C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl- 11 C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl- 11 C]Org 34850 may still represent a suitable candidate for imaging GRs in humans

  10. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer.

    Science.gov (United States)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W M M; Wiegerinck, Peter H G; Pietzsch, Jens; Bergmann, Ralf

    2009-02-01

    The radiosynthesis of [N-methyl-(11)C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [(11)C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23+/-5% (decay-corrected, based upon [(11)C]CO(2)) at a specific activity of 47+/-12 GBq/micromol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl-(11)C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl-(11)C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl-(11)C]Org 34850 may still represent a suitable candidate for imaging GRs in humans.

  11. Optical transitions in Ge/SiGe multiple quantum wells with Ge-rich barriers

    Science.gov (United States)

    Bonfanti, M.; Grilli, E.; Guzzi, M.; Virgilio, M.; Grosso, G.; Chrastina, D.; Isella, G.; von Känel, H.; Neels, A.

    2008-07-01

    Direct-gap and indirect-gap transitions in strain-compensated Ge/SiGe multiple quantum wells with Ge-rich SiGe barriers have been studied by optical transmission spectroscopy and photoluminescence experiments. An sp3d5s∗ tight-binding model has been adopted to interpret the experimental results. Photoluminescence spectra and their comparison with theoretical calculations prove the existence of type-I band alignment in compressively strained Ge quantum wells grown on relaxed Ge-rich SiGe buffers. The high quality of the transmission spectra opens up other perspectives for application of these structures in near-infrared optical modulators.

  12. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    International Nuclear Information System (INIS)

    2008-01-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  13. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  14. Photoproduction in the Energy Range 70-200 GeV

    CERN Multimedia

    2002-01-01

    This experiment continues the photoproduction studies of WA4 and WA57 up to the higher energies made available by the upgrading of the West Hall. An electron beam of energy 200 GeV is used to produce tagged photons in the range 65-180 GeV; The photon beam is incident on a 60 cm liquid hydrogen target in the Omega Spectrometer. A Ring Image Cherenkov detector provides pion/kaon separation up to 150 GeV/c. The Transition Radiation Detector extends the charged pion identification to the momentum range from about 80 GeV/c upwards. The large lead/liquid scintillator calorimeter built by the WA70 collaboration and the new lead/scintillating fibre det (Plug) are used for the detection of the $\\gamma$ rays produced by the interactions of the primary photons in the hydrogen target. \\\\ \\\\ The aim is to make a survey of photoproduction reactions up to photon energies of 200 GeV. The large aperture of the Omega Spectrometer will particularly enable study of fragmentation of the photon to states of high mass, up to @C 9 G...

  15. Application of radiotracers in an exotic field of botany. How to feed carnivorous plants

    International Nuclear Information System (INIS)

    Steinhauser, G.; Musilek, A.; Sterba, J.H.; Bichler, M.; Adlassnig, W.; Peroutka, M.; Lichtscheidl, I.K.

    2007-01-01

    In this paper, methods for the application of radiotracers in the Cobra Lily (Darlingtonia californica), a carnivorous pitcher plant, are described. The uptake of radiotracers such as 42 K and 54 Mn into the pitcher trap in aqueous solution could be proven, whereas uptake of 59 Fe ions could not be observed. No-carrier-added 54 Mn was taken up by the plants, regardless of extremely low concentrations. In contrast to earlier experiments using 14 C and 15 N-based tracers, the methodology presented allows quick, simple and reliable quantification of the nutrient uptake. The results of our experiments lead to a deeper biological understanding concerning the trace element household of this carnivorous plant and the absorption of micro- and macronutrients from trapped prey. (author)

  16. Radiotracer applications in industry - A guidebook

    International Nuclear Information System (INIS)

    2004-01-01

    The objective of this guidebook is to provide the radiotracer practitioner with practical, experience based information about all the facets of an investigation: design, planning, implementation, data treatment and interpretation of results. It is aimed at clearly identifying the questions that need to be asked at each stage of the investigation and, as comprehensively as possible, to either provide the answers to those questions or identify appropriate works of reference. The primary focus is on the methodology of radio tracing. Discussed aspects of the methodology are: tracer selection and optimization, methods of tracer injection, detection and measurement of radiation, data treatment and filtering including identification of available software, data analysis, interpretation and modelling. An early consideration in designing an investigation is selection of the tracer. The criteria of critical importance are that (1) the tracer must be compatible with the stream to be traced and (2) its behaviour must be representative of that stream. The first decision to make is whether to use a radioactive tracer or some alternative type. Generally, if the objectives of the investigation can be achieved using a non-radioactive tracer and without incurring disproportionate costs, then that tracer should be used. However, as will become apparent from the case studies presented, there are many problems that can be investigated only by using a radiotracer. In these cases it is necessary to choose a tracer based on the following selection criteria: type of radiation emitted: alpha particle, beta particle or gamma ray, half-life of the radionuclide, energy of the emitted radiation and optimization of the activity injected. The methodology reviewed considers the most commonly used radioisotopes for tracing solid materials, aqueous solutions, organic liquids and gaseous phases. The main emphasis is on the practical aspects of the technology. Various types of injection system are

  17. Development of high responsivity Ge:Ga photoconductors

    International Nuclear Information System (INIS)

    Haegel, N.M.; Hueschen, M.R.; Haller, E.E.

    1984-06-01

    Czochralski-grown gallium-doped germanium (Ge:Ga) single crystal samples with a compensation of 10 -4 have been modified by the indiffusion of Cu to produce photoconductors which provide NEPs comparable to current optimum Ge:Ga detectors, but exhibit responsivities a factor of 5 to 6 times higher when tested at a background photon flux of 10 8 photons/sec at lambda=93 μm. The introduction of Cu, a triple acceptor in Ge which acts as a neutral scattering center, reduces carrier mobility and extends the breakdown field significantly in this ultra-low compensation material

  18. Measurement of the neutron-capture cross section of 76Ge and 74Ge below 15 MeV and its relevance to 0 νββ decay searches of 76Ge

    Science.gov (United States)

    Bhike, Megha; Fallin, B.; Krishichayan; Tornow, W.

    2015-02-01

    The neutron radiative-capture cross section of 76Ge was measured between 0.4 and 14.8 MeV using the activation technique. Germanium samples with the isotopic abundance of ∼ 86%76Ge and ∼ 14%74Ge used in the 0 νββ searches by the GERDA and Majorana Collaborations were irradiated with monoenergetic neutrons produced at eleven energies via the 3H (p , n)3He, 2H (d , n)3He and 3H (d , n)4He reactions. Previously, data existed only at thermal energies and at 14 MeV. As a by-product, capture cross-section data were also obtained for 74Ge at neutron energies below 8 MeV. Indium and gold foils were irradiated simultaneously for neutron fluence determination. High-resolution γ-ray spectroscopy was used to determine the γ-ray activity of the daughter nuclei of interest. For the 76Ge total capture cross section the present data are in good agreement with the TENDL-2013 model calculations and the ENDF/B-VII.1 evaluations, while for the 74Ge (n , γ)75Ge reaction, the present data are about a factor of two larger than predicted. It was found that the 74Ge (n , γ)75Ge yield in the High-Purity Germanium (HPGe) detectors used by the GERDA and Majorana Collaborations is only about a factor of two smaller than the 76Ge (n , γ)77Ge yield due to the larger cross section of the former reaction.

  19. Asymmetry in angular distributions of Drell-Yan dimuons produced by antiproton-tungsten interactions at 125 GeV/c and partial coherence

    International Nuclear Information System (INIS)

    Blazek, M.

    1991-01-01

    Recently published data on angular distributions of high mass dimuons produced in proton-tungsten interactions at 125 GeV/c are considered in the frame of the quantum statistical approach involving a mixture of coherent and stochastic production. The analysis leads to the conclusion that a portion of the lepton pairs is produced coherently. An accurate description of the data specifying the asymmetric angular distributions requires a non-vanishing cubic term in cosine of the polar angle and a term with treble the azimuthal angle. This can be achieved by an appropriate interplay of the parameters entering the approach which includes the partial coherency. (author). 1 tab., 19 refs

  20. Radiotracer study on the efficiency of a cylindrical 2-stage anaerobic sludge digester

    International Nuclear Information System (INIS)

    Sung-Hee Jung; Joon-Ha Jin; Jong-Bum Kim

    2004-01-01

    Radiotracer experiments were carried out on a cylindrical 2-stage anaerobic sludge digester in order to investigate the improvement of their efficiency by means of RTD (residence time distribution) measurements before and after cleaning up the inside of the digester. The tracer was scandium in an EDTA solution which forms such a stable complex compound to keep the isotope form being adsorbed onto the surface of the pipelines or the wall. It was injected into the digester by pressurized nitrogen gas and its movement was monitored by NaI(Tl) scintillation detectors installed around the digester and recorded for a month by a 24-channel data acquisition system specially developed for radiotracer experiments by the Korea Tracer Group of KAERI. The experimental data was analysed for the MRT (mean residence time) and other parameters characterizing the flow behaviour. (author)

  1. Spectrum analysis of radiotracer residence time distribution for industrial and environmental applications

    International Nuclear Information System (INIS)

    Kasban, H.; Ashraf Hamid

    2014-01-01

    Radiotracer signal analysis and recognition still represents challenges in industrial and environmental applications specially in residence time distribution (RTD) measurement. This paper presents a development for the RTD signal recognition method that is based on power density spectrum (PDS). In this development, the features are extracted from the signals and/or from their higher-orders statistics (HOS) (Bispectrum and Trispectrum) instead of PDS. The HOS are estimated using direct, indirect and parametric estimations. The recognition results are analyzed and compared for different HOS estimation in order to select the best HOS estimation method for the purpose of RTD signal recognition. The artificial neural networks are used for training and testing of the proposed method. The proposed method is tested using RTD signals obtained from the measurements carried out using radiotracer technique. The simulation results show that the parametric estimation of the Trispectrum gives the higher recognition rate and is the most reliable for the RTD signal recognition. (author)

  2. The applicability of radiotracers for the investigation of the distillation of hydrocarbons

    International Nuclear Information System (INIS)

    Graczyk, J.; Iller, E.

    1976-01-01

    The use of radioactive tracers provide valuable methods for the investigation of distillation processes and have been applied to determine the characteristics of material streams, the dynamics of flowing phases and the composition in various parts of the distillation equipment. A method is proposed for testing individual radiotracers emplozemployed for the investigation of the distillation of hydrocarbons. The method consists in laboratory-scale distillation of a tracer together with a multicomponent hydrocarbon mixture, namely a gasoline fraction. The purification efficiency, distillation characteristics, and effective radiochemical purity of several tracers (reactor activated bromobenzene and synthesized C 3 H 7 82 Br, C 4 H 9 82 Br, C 5 H 11 82 Br) have been investigated. The distillation characteristics of bromohydrocarbons labelled with 82 Br and selected hydrocarbons tagged with 14 C (benzene and cumene) have been compared. The radiotracers investigated were employed for the determination of the hydrodynamic parameters of hydrocarbon distillation in laboratory packed columns and a commercial distillation tower. (author)

  3. Interfacial processes in the Pd/a-Ge:H system

    Science.gov (United States)

    Edelman, F.; Cytermann, C.; Brener, R.; Eizenberg, M.; Weil, R.; Beyer, W.

    1993-06-01

    The kinetics of phase transformation has been studied in a two-layer structure of Pd/a-Ge:H after vacuum annealing at temperatures from 180 to 500°C. The a-Ge:H was deposited at 250°C on both c-Si and cleaved NaCl substrates in an RF glow discharge from a GeH 4/H 2 mixture. It was found that, similarly to the Pd/c-Ge and the Pd/a-Ge (e-gun deposited) systems, in the case of 0.15-0.2 μm Pd/0.6-1.0 μm a-Ge:H interfacial germanides formed first through the production of Pd 2Ge (plus a small amount of PdGe), and then PdGe was produced. The growth of both compounds was found to be diffusion-controlled. The nonreacted a-Ge:H layer beneath the germanide overlayer crystallized at 400-500°C. A reverse sequence of germanides formation was revealed in the case of 50 nm Pd/30 nm a-Ge:H, studied by in situ heat treatment in the TEM utilizing non-supported samples. The first germanide detected was PdGe and then, as a result of PdGe and Ge reaction or the PdGe decomposition, Pd 2Ge formed. The temperature dependence of the incubation time before the first ˜ 10 nm PdGe grains formed, followed an Arrhenius curve with an activation energy of 1.45 eV.

  4. Si/Ge intermixing during Ge Stranski–Krastanov growth

    Directory of Open Access Journals (Sweden)

    Alain Portavoce

    2014-12-01

    Full Text Available The Stranski–Krastanov growth of Ge islands on Si(001 has been widely studied. The morphology changes of Ge islands during growth, from nucleation to hut/island formation and growth, followed by hut-to-dome island transformation and dislocation nucleation of domes, have been well described, even at the atomic scale, using techniques such as scanning tunneling microscopy and transmission electron microscopy. Although it is known that these islands do not consist of pure Ge (due to Si/Ge intermixing, the composition of the Ge islands is not precisely known. In the present work, atom probe tomography was used to study the composition of buried dome islands at the atomic scale, in the three-dimensional space. The core of the island was shown to contain about 55 atom % Ge, while the Ge composition surrounding this core decreases rapidly in all directions in the islands to reach a Ge concentration of about 15 atom %. The Ge distribution in the islands follows a cylindrical symmetry and Ge segregation is observed only in the {113} facets of the islands. The Ge composition of the wetting layer is not homogeneous, varying from 5 to 30 atom %.

  5. Ge/graded-SiGe multiplication layers for low-voltage and low-noise Ge avalanche photodiodes on Si

    Science.gov (United States)

    Miyasaka, Yuji; Hiraki, Tatsurou; Okazaki, Kota; Takeda, Kotaro; Tsuchizawa, Tai; Yamada, Koji; Wada, Kazumi; Ishikawa, Yasuhiko

    2016-04-01

    A new structure is examined for low-voltage and low-noise Ge-based avalanche photodiodes (APDs) on Si, where a Ge/graded-SiGe heterostructure is used as the multiplication layer of a separate-absorption-carrier-multiplication structure. The Ge/SiGe heterojunction multiplication layer is theoretically shown to be useful for preferentially enhancing impact ionization for photogenerated holes injected from the Ge optical-absorption layer via the graded SiGe, reflecting the valence band discontinuity at the Ge/SiGe interface. This property is effective not only for the reduction of operation voltage/electric field strength in Ge-based APDs but also for the reduction of excess noise resulting from the ratio of the ionization coefficients between electrons and holes being far from unity. Such Ge/graded-SiGe heterostructures are successfully fabricated by ultrahigh-vacuum chemical vapor deposition. Preliminary pin diodes having a Ge/graded-SiGe multiplication layer act reasonably as photodetectors, showing a multiplication gain larger than those for diodes without the Ge/SiGe heterojunction.

  6. In Vivo Metabolic Trapping Radiotracers for Imaging Monoamine Oxidase-A and –B Enzymatic Activity

    Science.gov (United States)

    Brooks, Allen F.; Shao, Xia; Quesada, Carole A.; Sherman, Phillip; Scott, Peter J.H.; Kilbourn, Michael R.

    2017-01-01

    The isozymes of monoamine oxidase (MAO-A and MAO-B) are important enzymes involved in the metabolism of numerous biogenic amines, including the neurotransmitters serotonin, dopamine and norepinephrine. Recently, changes in concentrations of MAO-B have been proposed as an in vivo marker of neuroinflammation associated with Alzheimer’s disease. Previous developments of in vivo radiotracers for imaging changes in MAO enzyme expression or activity have utilized the irreversible propargylamine-based suicide inhibitors, or high-affinity reversibly-binding inhibitors. As an alternative approach, we have investigated 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines as metabolic trapping agents for the monoamine oxidases. MAO-mediated oxidation and spontaneous hydrolysis yields 1-[11C]methyl-2,3-dihydro-4-pyridinone as a hydrophilic metabolite that is trapped within brain tissues. Radiotracers with phenyl, biphenyl and 7-coumarinyl ethers were evaluated using microPET imaging in rat and primate brain. No isozyme selectivity for radiotracer trapping was observed in the rat brain for any compound, but in the monkey brain the phenyl ether demonstrated MAO-A selectivity, and the coumarinyl ether showed MAO-B selectivity. These are lead compounds for further development of 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines with optimized brain pharmacokinetics and isozyme selectivity. PMID:26393369

  7. Observation of a meson X → 2γ, with mass 2.85 GeV/c2, produced in the charge-exchange reaction π-p→Xn at 40 Gev/c

    International Nuclear Information System (INIS)

    Apel, W.D.; Augenstein, K.H.; Bertolucci, E.; Donskov, S.V.; Inyakin, A.V.; Kachanov, V.A.; Krasnokutsky, R.N.; Kruger, M.; Leder, G.; Lednev, A.A.; Mannelli, I.; Mikhailov, Yu.V.; Mueller, H.; Pierazzini, G.M.; Prokoshkin, Yu.D.; Quaglia, M.; Schneider, H.; Scribano, A.; Sergiampietri, F.; Shuvalov, R.S.; Sigurdsson, G.; Toropin, A.N.; Vincelli, M.L.

    1978-01-01

    The invariant mass spectrum of neutral final states produced in π - p charge-exchange scattering at 40 GeV/c has been studied, searching for heavy particles decaying into 2γ. A peak is observed around 2.85 GeV/c 2 . The cross section of the reaction π - p→X(2.85)+n, times the branching ratio of the X→2γ decay, is measured to be sigma X BR approximately =2X10 -34 cm 2 . (Auth.)

  8. Chemical fate of the nicotinic acetylcholinergic radiotracer [123I]5-IA-85380 in baboon brain and plasma

    International Nuclear Information System (INIS)

    Baldwin, Ronald M.; Zoghbi, Sami S.; Staley, Julie K.; Brenner, Eric; Al-Tikriti, Mohammed S.; Amici, Louis; Fujita, Masahiro; Innis, Robert B.; Tamagnan, Gilles

    2006-01-01

    The fate of the nicotinic acetylcholinergic receptor radiotracer [ 123 I]5-IA-85380 ([ 123 I]5-IA) was studied in baboon by analyzing the chemical composition of brain tissue and plasma after intravenous administration of the tracer. Acetonitrile denaturation and high-performance liquid chromatography (HPLC) analysis showed predominantly unchanged (91-98%) parent tracer in all brain tissues examined, compared to significant metabolism (23% parent) in the plasma at 90 min postinjection, and control tissue recovery of 95-98%. [ 123 I]5-IA was distributed to the thalamus with a standardized uptake value of 9.2 (0.04% dose/g) or a concentration 5.8 times higher than that of the cerebellum. The HPLC behavior of a synthesized sample of one hypothesized metabolite, 5-iodo-3-pyridinol (5-IP), was consistent with plasma radiometabolite fraction. Since only parent radiotracer compound was found in brain tissue, these results add confidence that information derived from single photon emission computed tomography images of 123 I activity in the brain after [ 123 I]5-IA administration can be interpreted as distribution of an intact radiotracer

  9. Gamma-gamma angular correlations in the 71 Ga and 69 Ga nuclei

    International Nuclear Information System (INIS)

    Bairrio Nuevo Junior, A.

    1975-01-01

    The directional correlations of v-transitions in 71 Ga and 69 Ga have been measured from the decay of 71 Z n and 69 Ge respectively using a Ge(Li)-NaI (f pound) gamma spectrometer. Spin assignments to the levels in Ga at 390(1/2), 487 (5/2 ) , 512(3/2 ) , 964(5/2 ) , 1107(7/2 ) , 1494(9/2*) and 2247 KeV(7/2 ), and 69 Ga at 318(1/2) , 574(5/2) , 872(3/2), 1106(5/2 , 3/2 ) , 1336(7/2 ) , and 1923 KeV(7/2) confirm the results of previous studies on these nuclei . The multipole mixing ratios 6(E2/M1) for several γ-transitions in both nuclei have been determined from the present angular correlation data. The results are: 6(121) - -0.2 * 6(142) * 0.04 - - 0.04, 6(386) = -0.003 - 0.014, 6(487) = 0.04 - 0.07, 5(512) - -0.14 - 0.10, 6(620) = 1.3 * j j and, 6(753) - 0.00 - 0.01 and 6(964) = 0.6 + Q 9 for transitions i n 71 Ga and 6(234) much greater than 0.28 - 0.04 or 0.08 - 0.02, 6(587) - -1.1 - 0.08, 6(1051) much greater than 0.0 - 0.10 and 6(1349) - 0.13 - 0.03 for transitions in 69 Ga . The experimental results are discussed in terms of various nuclear models which are applicable for the odd-A nuclei in this mass region. (author)

  10. Inactivated Enterovirus 71 Vaccine Produced by 200-L Scale Serum-Free Microcarrier Bioreactor System Provides Cross-Protective Efficacy in Human SCARB2 Transgenic Mouse.

    Science.gov (United States)

    Wu, Chia-Ying; Lin, Yi-Wen; Kuo, Chia-Ho; Liu, Wan-Hsin; Tai, Hsiu-Fen; Pan, Chien-Hung; Chen, Yung-Tsung; Hsiao, Pei-Wen; Chan, Chi-Hsien; Chang, Ching-Chuan; Liu, Chung-Cheng; Chow, Yen-Hung; Chen, Juine-Ruey

    2015-01-01

    Epidemics and outbreaks caused by infections of several subgenotypes of EV71 and other serotypes of coxsackie A viruses have raised serious public health concerns in the Asia-Pacific region. These concerns highlight the urgent need to develop a scalable manufacturing platform for producing an effective and sufficient quantity of vaccines against deadly enteroviruses. In this report, we present a platform for the large-scale production of a vaccine based on the inactivated EV71(E59-B4) virus. The viruses were produced in Vero cells in a 200 L bioreactor with serum-free medium, and the viral titer reached 10(7) TCID50/mL 10 days after infection when using an MOI of 10(-4). The EV71 virus particles were harvested and purified by sucrose density gradient centrifugation. Fractions containing viral particles were pooled based on ELISA and SDS-PAGE. TEM was used to characterize the morphologies of the viral particles. To evaluate the cross-protective efficacy of the EV71 vaccine, the pooled antigens were combined with squalene-based adjuvant (AddaVAX) or aluminum phosphate (AlPO4) and tested in human SCARB2 transgenic (Tg) mice. The Tg mice immunized with either the AddaVAX- or AlPO4-adjuvanted EV71 vaccine were fully protected from challenges by the subgenotype C2 and C4 viruses, and surviving animals did not show any degree of neurological paralysis symptoms or muscle damage. Vaccine treatments significantly reduced virus antigen presented in the central nervous system of Tg mice and alleviated the virus-associated inflammatory response. These results strongly suggest that this preparation results in an efficacious vaccine and that the microcarrier/bioreactor platform offers a superior alternative to the previously described roller-bottle system.

  11. Searches for supersymmetry in the photon(s) plus missing energy channels at $\\sqrt{s}$ = 161 GeV and 172 GeV

    CERN Document Server

    Barate, R.; Decamp, D.; Ghez, Philippe; Goy, C.; Lees, J.P.; Lucotte, A.; Minard, M.N.; Nief, J.Y.; Pietrzyk, B.; Casado, M.P.; Chmeissani, M.; Comas, P.; Crespo, J.M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, L.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, L.M.; Padilla, C.; Park, I.C.; Pascual, A.; Perlas, J.A.; Riu, I.; Sanchez, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Bazarko, A.O.; Becker, U.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Dissertori, G.; Drevermann, H.; Forty, R.W.; Frank, M.; Hagelberg, R.; Hansen, J.B.; Harvey, John; Janot, P.; Jost, B.; Kneringer, E.; Lehraus, I.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.F.; Ranjard, F.; Rizzo, G.; Rolandi, Gigi; Rousseau, D.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Teubert, F.; Tomalin, I.R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barres, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.M.; Fearnley, T.; Hansen, J.D.; Hansen, J.R.; Hansen, P.H.; Nilsson, B.S.; Rensch, B.; Waananen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J.C.; Machefert, F.; Rouge, A.; Rumpf, M.; Valassi, A.; Videau, H.; Boccali, T.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Huehn, T.; Jaffe, D.E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G.P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S.J.; Halley, A.W.; Knowles, I.G.; Lynch, J.G.; O'Shea, V.; Raine, C.; Scarr, J.M.; Smith, K.; Teixeira-Dias, P.; Thompson, A.S.; Thomson, Evelyn J.; Thomson, F.; Turnbull, R.M.; Buchmuller, O.; Dhamotharan, S.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E.E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D.M.; Cameron, W.; Dornan, P.J.; Girone, M.; Goodsir, S.; Martin, E.B.; Morawitz, P.; Moutoussi, A.; Nash, J.; Sedgbeer, J.K.; Spagnolo, P.; Stacey, A.M.; Williams, M.D.; Ghete, V.M.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A.P.; Bowdery, C.K.; Buck, P.G.; Colrain, P.; Crawford, G.; Finch, A.J.; Foster, F.; Hughes, G.; Jones, R.W.L.; Sloan, T.; Whelan, E.P.; Williams, M.I.; Giehl, I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J.J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Carr, J.; Coyle, P.; Diaconu, C.; Ealet, A.; Fouchez, D.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Talby, M.; Sadouki, A.; Thulasidas, M.; Tilquin, A.; Trabelsi, K.; Aleppo, M.; Antonelli, M.; Ragusa, F.; Berlich, R.; Blum, W.; Buescher, Volker; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lutjens, G.; Lutz, G.; Manner, W.; Moser, H.G.; Richter, Robert, 1; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, Richard Dante; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.F.; Heusse, Ph.; Hocker, Andreas; Jacholkowska, A.; Jacquet, M.; Kim, D.W.; Le Diberder, F.; Lefrancois, J.; Lutz, A.M.; Nikolic, Irina; Schune, M.H.; Serin, L.; Simion, S.; Tournefier, E.; Veillet, J.J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, Giuseppe; Bettarini, S.; Bozzi, C.; Calderini, G.; Ciulli, V.; Dell'Orso, R.; Fantechi, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P.S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciaba, A.; Sguazzoni, G.; Steinberger, J.; Tenchini, R.; Vannini, C.; Venturi, A.; Verdini, P.G.; Blair, G.A.; Bryant, L.M.; Chambers, J.T.; Gao, Y.; Green, M.G.; Medcalf, T.; Perrodo, P.; Strong, J.A.; von Wimmersperg-Toeller, J.H.; Botterill, D.R.; Clifft, R.W.; Edgecock, T.R.; Haywood, S.; Maley, P.; Norton, P.R.; Thompson, J.C.; Wright, A.E.; Bloch-Devaux, Brigitte; Colas, P.; Fabbro, B.; Kozanecki, W.; Lancon, E.; Lemaire, M.C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.F.; Rosowsky, A.; Roussarie, A.; Schuller, J.P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S.N.; Dann, J.H.; Kim, H.Y.; Litke, A.M.; McNeil, M.A.; Taylor, G.; Booth, C.N.; Boswell, R.; Brew, C.A.J.; Cartwright, S.; Combley, F.; Kelly, M.S.; Lehto, M.; Newton, W.M.; Reeve, J.; Thompson, L.F.; Affholderbach, K.; Boehrer, Armin; Brandt, S.; Cowan, G.; Foss, J.; Grupen, C.; Lutters, G.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R.W.; Armstrong, S.R.; Charles, E.; Elmer, P.; Ferguson, D.P.S.; Gonzalez, S.; Greening, T.C.; Hayes, O.J.; Hu, H.; Jin, S.; McNamara, P.A., III; Nachtman, J.M.; Nielsen, J.; Orejudos, W.; Pan, Y.B.; Saadi, Y.; Scott, I.J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Yamartino, J.M.; Zobernig, G.

    1998-01-01

    Searches for supersymmetric particles in channels with one or more photons and missing energy have been performed with data collected by the ALEPH detector at LEP. The data consist of 11.1 \\pb\\ at $\\sqrt{s} = 161 ~\\, \\rm GeV$, 1.1 \\pb\\ at 170 \\gev\\ and 9.5 \\pb\\ at 172 GeV. The \\eenunu\\ cross se ction is measured. The data are in good agreement with predictions based on the Standard Model, and are used to set upper limits on the cross sections for anomalous photon production. These limits are compared to two different SUSY models and used to set limits on the neutralino mass. A limit of 71 \\gevsq\\ at 95\\% C.L. is set on the mass of the lightest neutralin o ($\\tau_{\\chi_{1}^{0}} \\leq $ 3 ns) for the gauge-mediated supersymmetry breaking and LNZ models.

  12. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    The seasonal variation in sulfate reduction and the dynamics of sulfur and iron geochemistry were studied throughout a year in sediment of Aarhus Bay, Denmark. A radiotracer method for measuring sulfate reduction rates was applied with incubation times down to 15 min and a depth resolution down...... to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  13. Application of centrifuge modelling and radiotracers to migration studies of buried toxic waste

    International Nuclear Information System (INIS)

    Villar, H.P.

    1995-01-01

    A new technique to study the migration of souble waste components in soils, based on the application of centrifugue modelling and of selected short-lived radiotracers, is presented. The technique is based on the acceleration of the migration proceses of a specific tracer in a soil model, with simple and well-established scaling laws being used to interpret the results. The use of radiotracers allows geat flexibility and the adoption of a wide range of concentrations. Demosntrations of the technique have been carried out with two elements of radically distinct behaviour: iodine noted for its mobility in soils, and thallium, which tends to be strongly sorbed. Two different soil types have been used. The results semed to confirm what is known about the behaviour of both elements, so that the feasibility of the technique for such studies has been concluded. (author). 7 refs, 4 figs, 1 tab

  14. Neutron measurements in the stray field produced by 158 GeV/c lead ion beams

    International Nuclear Information System (INIS)

    Agosteo, S.; Birattari, C.; Foglio Para, A.; Nava, E.; Silari, M.; Ulrici, L.

    1997-01-01

    This paper discusses measurements carried out at CERN in the stray radiation field produced by 158 GeV/c 208 Pb 82+ ions. The purpose was to test and intercompare the response of several detectors, mainly neutron measuring devices, and to determine the neutron spectral fluence as well as the microdosimetric (absorbed dose and dose equivalent) distributions in different locations around the shielding. Both active instruments and passive dosimeters were employed, including different types of Andersson-Braun rem counters, a tissue equivalent proportional counter, a set of superheated drop detectors, a Bonner sphere system and different types of ion chambers. Activation measurements with 12 C plastic scintillators and with 32 S pellets were also performed to assess the neutron yield of high energy lead ions interacting with a thin gold target. The results are compared with previous measurements and with measurements made during proton runs. (author)

  15. Influence of the entrance channel in the fusion reaction 318 MeV 74Ge+74Ge

    International Nuclear Information System (INIS)

    Zhu, L.H.; Cinausero, M.; Angelis, G. de; De Poli, M.; Fioretto, E.; Gadea, A.; Napoli, D.R.; Prete, G.; Lucarelli, F.

    1998-01-01

    Entrance channel effects in the fusion of heavy ions have been studied by using the 74 Ge+ 74 Ge reaction at 318 MeV. The population of the yrast superdeformed band in 144 Gd shows an increase when compared with the results obtained in the more asymmetric 48 Ti+ 100 Mo reaction at 215 MeV. The relative yields of the different evaporation residues produced in the 74 Ge+ 74 Ge and in the 48 Ti+ 100 Mo reactions are very similar, with the exception of the 145,144 Gd residual nuclei (3n and 4n decay channels) which are populated with a larger yield in the symmetric reaction. Statistical model calculations reproduce qualitatively such effect if a fission delay is explicitly taken into account. Effects related to fusion barrier fluctuations seem to be important in determining the spin distributions of the compound nucleus. The spectra of the high energy γ-rays emitted in the 74 Ge+ 74 Ge reaction have been measured as a function of the γ-ray multiplicity as well as in coincidence with selected evaporation residues. They are reproduced by standard statistical model calculations with GDR parameters taken from systematics, demonstrating that, in agreement with dynamical model prediction, the emission of γ-rays from the dinucleus formed in the earlier stage of the collision is unimportant. (orig.)

  16. Recoil generated radiotracers in studies of molecular dynamics

    International Nuclear Information System (INIS)

    Spicer, L.D.

    1981-01-01

    This chapter summarizes many of the contributions that the recoil technique of generating excited radiotracer atoms in the presence of a thermal environment is making to the field of chemical dynamics. Specific topics discussed critically include characterization of the generation and behavior of excited molecules including fragmentation kinetics and energy transfer, measurement of thermal and hot kinetic parameters, and studies of reaction mechanisms and stereochemistry as a function of reaction energy. Distinctive features that provide unique approaches to dynamical problems are evaluated in detail and the complementarity with more conventional techniques is addressed. Prospects for future applications are also presented

  17. Inclusive and semi-inclusive distributions of neutral strange particles produced in π-p interactions at 4.9; 7.5 and 40 GeV/c

    International Nuclear Information System (INIS)

    Dzhmukhadze, S.V.; Kladnitskaya, E.N.; Popova, V. M.; Toneeva, G.P.

    1978-01-01

    Results on the investigation of inclusive and semi-inclusive distributions of Λ and K 0 particles, produced in π - p interactions at 4.9, 7.5 and 40 GeV/c are presen--ted. It is shown that the inclusive cross section for production of Ksup(0) mesons increases with the energy mainly in the central region, while the inclusive production of Λ hyperons increases in the fragmentation region of the target proton. The normalized structure fucntion PHIsub(x) for K 0 mesons does not achieve the scaling in the considered energy range, while the function PHIsub(x) for Λ hyperons has the scaling behaviour in a wide range of x, -0.5 < x (<=) 0.1 starting from 4.9 GeV/c

  18. A radiotracer method for the dynamic measurement of the in-process inventory of dissolved materials

    International Nuclear Information System (INIS)

    Iqbal, M.N.; Gardner, R.P.; Verghese, K.

    1990-01-01

    A radioactive tracer method and the associated mathematical models have been developed to determine the in-process inventory of zirconium in a pulse column from the counting rate data taken at the exits of the aqueous and organic phases after an impulse injection of the radiotracer at the aqueous-phase inlet. Model parameters were obtained by applying a nonlinear least-squares fitting of the models to the experimental data. The total inventory of zirconium present in the pulse column under different operating conditions was determined by calculating the average residence time of zirconium in the system using these model parameters. The results indicate that the radiotracer technique provides a viable means of on-line determination of solute mass holdup. (author)

  19. Analysis of threshold current of uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers.

    Science.gov (United States)

    Jiang, Jialin; Sun, Junqiang; Gao, Jianfeng; Zhang, Ruiwen

    2017-10-30

    We propose and design uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers with the stress along direction. The micro-bridge structure is adapted for introducing uniaxial stress in Ge/SiGe quantum well. To enhance the fabrication tolerance, full-etched circular gratings with high reflectivity bandwidths of ~500 nm are deployed in laser cavities. We compare and analyze the density of state, the number of states between Γ- and L-points, the carrier injection efficiency, and the threshold current density for the uniaxially tensile stressed bulk Ge and Ge/SiGe quantum well lasers. Simulation results show that the threshold current density of the Ge/SiGe quantum well laser is much higher than that of the bulk Ge laser, even combined with high uniaxial tensile stress owing to the larger number of states between Γ- and L- points and extremely low carrier injection efficiency. Electrical transport simulation reveals that the reduced effective mass of the hole and the small conduction band offset cause the low carrier injection efficiency of the Ge/SiGe quantum well laser. Our theoretical results imply that unlike III-V material, uniaxially tensile stressed bulk Ge outperforms a Ge/SiGe quantum well with the same strain level and is a promising approach for Si-compatible light sources.

  20. Si/SiGe heterointerfaces in one-, two-, and three-dimensional nanostructures: their impact on SiGe light emission

    Science.gov (United States)

    Lockwood, David; Wu, Xiaohua; Baribeau, Jean-Marc; Mala, Selina; Wang, Xialou; Tsybeskov, Leonid

    2016-03-01

    Fast optical interconnects together with an associated light emitter that are both compatible with conventional Si-based complementary metal-oxide- semiconductor (CMOS) integrated circuit technology is an unavoidable requirement for the next-generation microprocessors and computers. Self-assembled Si/Si1-xGex nanostructures, which can emit light at wavelengths within the important optical communication wavelength range of 1.3 - 1.55 μm, are already compatible with standard CMOS practices. However, the expected long carrier radiative lifetimes observed to date in Si and Si/Si1-xGex nanostructures have prevented the attainment of efficient light-emitting devices including the desired lasers. Thus, the engineering of Si/Si1-xGex heterostructures having a controlled composition and sharp interfaces is crucial for producing the requisite fast and efficient photoluminescence (PL) at energies in the range 0.8-0.9 eV. In this paper we assess how the nature of the interfaces between SiGe nanostructures and Si in heterostructures strongly affects carrier mobility and recombination for physical confinement in three dimensions (corresponding to the case of quantum dots), two dimensions (corresponding to quantum wires), and one dimension (corresponding to quantum wells). The interface sharpness is influenced by many factors such as growth conditions, strain, and thermal processing, which in practice can make it difficult to attain the ideal structures required. This is certainly the case for nanostructure confinement in one dimension. However, we demonstrate that axial Si/Ge nanowire (NW) heterojunctions (HJs) with a Si/Ge NW diameter in the range 50 - 120 nm produce a clear PL signal associated with band-to-band electron-hole recombination at the NW HJ that is attributed to a specific interfacial SiGe alloy composition. For three-dimensional confinement, the experiments outlined here show that two quite different Si1-xGex nanostructures incorporated into a Si0.6Ge0.4 wavy

  1. Employment of the technique of radiotracers for analysis of industrial filters

    International Nuclear Information System (INIS)

    Ramos, Vitor Santos; Crispim, Verginia Reis

    2007-01-01

    The main aim of this work is to develop a methodology to evaluate the characteristics of porous media in filter using the radio-tracing technique. To do this, an experimental prototype filter made up of an acrylic cylinder, vertically mounted and supported on the lower side by a controlled leaking valve was developed. Two filters (spheres of acrylic and silica crystals) were used to check the movement of the water through the porous media using 123 I in its MIBG (iodine-123-meta-iodo benzyl-guanidine) form. Further up the filter an instantaneous injection of the substance makes it possible to see the passage of radioactive clouds through the two scintillatory detectors NaI (2x2) ' ' positioned before and immediately after the cylinder with the filtering element (porous media). The are caused by the detectors on the passage of the radioactive cloud are analyzed through statistical functions using the weighted moment method which makes it possible to calculate the Residence-Time (the amount of time the tracer takes to thoroughly pass through the filter) per the equation of dispersion in tubular flow and the one-directional flow of the radiotracer in the porous media. (author)

  2. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.

  3. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of 11 C, 18 F and 13 N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume

  4. In Vivo Imaging of Experimental Melanoma Tumors using the Novel Radiotracer 68Ga-NODAGA-Procainamide (PCA).

    Science.gov (United States)

    Kertész, István; Vida, András; Nagy, Gábor; Emri, Miklós; Farkas, Antal; Kis, Adrienn; Angyal, János; Dénes, Noémi; Szabó, Judit P; Kovács, Tünde; Bai, Péter; Trencsényi, György

    2017-01-01

    The most aggressive form of skin cancer is the malignant melanoma. Because of its high metastatic potential the early detection of primary melanoma tumors and metastases using non-invasive PET imaging determines the outcome of the disease. Previous studies have already shown that benzamide derivatives, such as procainamide (PCA) specifically bind to melanin pigment. The aim of this study was to synthesize and investigate the melanin specificity of the novel 68 Ga-labeled NODAGA-PCA molecule in vitro and in vivo using PET techniques. Procainamide (PCA) was conjugated with NODAGA chelator and was labeled with Ga-68 ( 68 Ga-NODAGA-PCA). The melanin specificity of 68 Ga-NODAGA-PCA was tested in vitro , ex vivo and in vivo using melanotic B16-F10 and amelanotic Melur melanoma cell lines. By subcutaneous and intravenous injection of melanoma cells tumor-bearing mice were prepared, on which biodistribution studies and small animal PET/CT scans were performed for 68 Ga-NODAGA-PCA and 18 FDG tracers. 68 Ga-NODAGA-PCA was produced with high specific activity (14.9±3.9 GBq/µmol) and with excellent radiochemical purity (98%PCA uptake of B16-F10 cells was significantly ( p ≤0.01) higher than Melur cells. Ex vivo biodistribution and in vivo PET/CT studies using subcutaneous and metastatic tumor models showed significantly ( p ≤0.01) higher 68 Ga-NODAGA-PCA uptake in B16-F10 primary tumors and lung metastases in comparison with amelanotic Melur tumors. In experiments where 18 FDG and 68 Ga-NODAGA-PCA uptake of B16-F10 tumors was compared, we found that the tumor-to-muscle (T/M) and tumor-to-lung (T/L) ratios were significantly ( p ≤0.05 and p ≤0.01) higher using 68 Ga-NODAGA-PCA than the 18 FDG accumulation. Our novel radiotracer 68 Ga-NODAGA-PCA showed specific binding to the melanin producing experimental melanoma tumors. Therefore, 68 Ga-NODAGA-PCA is a suitable diagnostic radiotracer for the detection of melanoma tumors and metastases in vivo .

  5. Development of gold nanoparticle radiotracers for investigating multiphase system in process industries

    International Nuclear Information System (INIS)

    Mohd Amirul Syafiq Mohd Yunos; Jaafar Abdullah; Engku Fahmi Engku Chik; Noraishah Othman

    2010-01-01

    This paper describes the development of colloidal 197 Au-SiO 2 with core-shell structure nanoparticle radiotracers. Using conventional citrate-reduction method, gold nanoparticles were prepared from its corresponding metal salts in aqueous solution then coated with uniform shells of amorphous silica via a sol-gel reaction. This target material of radiotracer application used to investigate multiphase system in process industries without disturbing the system operation. The citrate-reduction-based method provides gold nanoparticles with higher concentration and narrow size distribution. By using transmission electron microscopy (TEM), the resultant of particle size and silica coatings could be varied from tens to several hundred of nanometers by controlling the catalyzer and precipitation time. 197 Au-SiO 2 core-shell nano structure is good to prevent the particles from getting conglomerate resulting in a big mass. In addition, silica surface offer very good chances that make the hydrophobicity behavior on the gold nanoparticles. EDXRF spectrum has proven that 197 Au-SiO 2 core-shell nanoparticles sample consists purely of a gold and silica particles. (author)

  6. The use of rare earth radiotracers in the study of solvent extraction kinetics

    International Nuclear Information System (INIS)

    Lim, T.M.; Tran, T.

    1993-01-01

    The suitability of rare earth radionuclides as tracers in research and industry are assessed. In general, the most desirable characteristics of radiotracers for process studies are a half-life in the range 5-200 days, a high yield, high energy γ-emission and low cost of production. The majority of rare earths have at least one radionuclide with acceptable characteristics. The application of radiotracers to the study of kinetics of rare earth solvent extraction have been studied using a modified Lewis cell. Terbium-160 was selected as the most suitable rare earth radionuclide for our experiments. Samples of both aqueous and organic phases were continuous withdrawn, monitored using an automated γ-counting system based on two sodium iodide detectors and then pumped back to the Lewis cell. Excellent results were obtained and the rate of extraction was shown to be first order with respect to the terbium concentration. 6 refs., 1 tab., 7 figs

  7. Ferromagnetism in Fe{sub 3-x-y}Ni{sub x}GeTe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Stahl, Juliane; Johrendt, Dirk [Muenchen Univ. (Germany). Dept. Chemie; Pomjakushin, Vladimir [Paul Scherrer Institute, Villigen (Switzerland). Lab. for Neutron Scattering

    2016-07-01

    Polycrystalline samples of Fe{sub 3-y}GeTe{sub 2} (0.08 ≤ y ≤ 0.29) and the solid solutions Fe{sub 3-x-y}Ni{sub x}GeTe{sub 2} (0.24 ≤ x ≤ 1.32; 0.14 ≤ y ≤ 0.41) were synthesized at 898-973 K in a resistance furnace and characterized by X-ray and neutron powder diffraction with Rietveld analysis (Fe{sub 3}GeTe{sub 2} type, P6{sub 3}/mmc, a = 402.665(3), c = 1632.820(14) pm for x = 0, y = 0.08). Fe{sub 3}Ge layers with planar FeGe hexagons and additional iron atoms above and below the rings are separated by double layers of tellurium atoms. Fe{sub 3}GeTe{sub 2} is ferromagnetic below T{sub C} = 230 K with magnetic moments aligned along the c axis. T{sub C} depends on the iron content and decreases with increasing iron vacancies continuously to 153 K in Fe{sub 2.71}GeTe{sub 2}. Further reduction of T{sub C} is possible by nickel substitution until magnetic ordering is nearly absent in Fe{sub 1.33}Ni{sub 1.32}GeTe{sub 2}. The suppression of the magnetic ordering is caused by random dilution of the magnetic iron atoms either by vacancies or by non-magnetic nickel atoms.

  8. The Effects of Annealing Temperatures on Composition and Strain in Si x Ge1-x Obtained by Melting Growth of Electrodeposited Ge on Si (100).

    Science.gov (United States)

    Abidin, Mastura Shafinaz Zainal; Morshed, Tahsin; Chikita, Hironori; Kinoshita, Yuki; Muta, Shunpei; Anisuzzaman, Mohammad; Park, Jong-Hyeok; Matsumura, Ryo; Mahmood, Mohamad Rusop; Sadoh, Taizoh; Hashim, Abdul Manaf

    2014-02-24

    The effects of annealing temperatures on composition and strain in Si x Ge 1- x , obtained by rapid melting growth of electrodeposited Ge on Si (100) substrate were investigated. Here, a rapid melting process was performed at temperatures of 1000, 1050 and 1100 °C for 1 s. All annealed samples show single crystalline structure in (100) orientation. A significant appearance of Si-Ge vibration mode peak at ~400 cm -1 confirms the existence of Si-Ge intermixing due to out-diffusion of Si into Ge region. On a rapid melting process, Ge melts and reaches the thermal equilibrium in short time. Si at Ge/Si interface begins to dissolve once in contact with the molten Ge to produce Si-Ge intermixing. The Si fraction in Si-Ge intermixing was calculated by taking into account the intensity ratio of Ge-Ge and Si-Ge vibration mode peaks and was found to increase with the annealing temperatures. It is found that the strain turns from tensile to compressive as the annealing temperature increases. The Si fraction dependent thermal expansion coefficient of Si x Ge 1- x is a possible cause to generate such strain behavior. The understanding of compositional and strain characteristics is important in Ge/Si heterostructure as these properties seem to give significant effects in device performance.

  9. The Effects of Annealing Temperatures on Composition and Strain in SixGe1−x Obtained by Melting Growth of Electrodeposited Ge on Si (100)

    Science.gov (United States)

    Abidin, Mastura Shafinaz Zainal; Morshed, Tahsin; Chikita, Hironori; Kinoshita, Yuki; Muta, Shunpei; Anisuzzaman, Mohammad; Park, Jong-Hyeok; Matsumura, Ryo; Mahmood, Mohamad Rusop; Sadoh, Taizoh; Hashim, Abdul Manaf

    2014-01-01

    The effects of annealing temperatures on composition and strain in SixGe1−x, obtained by rapid melting growth of electrodeposited Ge on Si (100) substrate were investigated. Here, a rapid melting process was performed at temperatures of 1000, 1050 and 1100°C for 1 s. All annealed samples show single crystalline structure in (100) orientation. A significant appearance of Si-Ge vibration mode peak at ~00 cm−1 confirms the existence of Si-Ge intermixing due to out-diffusion of Si into Ge region. On a rapid melting process, Ge melts and reaches the thermal equilibrium in short time. Si at Ge/Si interface begins to dissolve once in contact with the molten Ge to produce Si-Ge intermixing. The Si fraction in Si-Ge intermixing was calculated by taking into account the intensity ratio of Ge-Ge and Si-Ge vibration mode peaks and was found to increase with the annealing temperatures. It is found that the strain turns from tensile to compressive as the annealing temperature increases. The Si fraction dependent thermal expansion coefficient of SixGe1−x is a possible cause to generate such strain behavior. The understanding of compositional and strain characteristics is important in Ge/Si heterostructure as these properties seem to give significant effects in device performance. PMID:28788521

  10. The Effects of Annealing Temperatures on Composition and Strain in SixGe1−x Obtained by Melting Growth of Electrodeposited Ge on Si (100

    Directory of Open Access Journals (Sweden)

    Mastura Shafinaz Zainal Abidin

    2014-02-01

    Full Text Available The effects of annealing temperatures on composition and strain in SixGe1−x, obtained by rapid melting growth of electrodeposited Ge on Si (100 substrate were investigated. Here, a rapid melting process was performed at temperatures of 1000, 1050 and 1100 °C for 1 s. All annealed samples show single crystalline structure in (100 orientation. A significant appearance of Si-Ge vibration mode peak at ~400 cm−1 confirms the existence of Si-Ge intermixing due to out-diffusion of Si into Ge region. On a rapid melting process, Ge melts and reaches the thermal equilibrium in short time. Si at Ge/Si interface begins to dissolve once in contact with the molten Ge to produce Si-Ge intermixing. The Si fraction in Si-Ge intermixing was calculated by taking into account the intensity ratio of Ge-Ge and Si-Ge vibration mode peaks and was found to increase with the annealing temperatures. It is found that the strain turns from tensile to compressive as the annealing temperature increases. The Si fraction dependent thermal expansion coefficient of SixGe1−x is a possible cause to generate such strain behavior. The understanding of compositional and strain characteristics is important in Ge/Si heterostructure as these properties seem to give significant effects in device performance.

  11. Characterization of electrochemical cell for production of radiotracer in organic medium

    International Nuclear Information System (INIS)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da; Coordenacao de Pos-Graduacao e Pesquisa de Engenharia

    2017-01-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  12. Characterization of electrochemical cell for production of radiotracer in organic medium

    Energy Technology Data Exchange (ETDEWEB)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da, E-mail: hkenup@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-11-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  13. [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine receptors using single photon emission computer tomography; [{sup 123}I]-3-Iodcytisin als moeglicher Radiotracer fuer die Darstellung der nikotinergen Acetylcholin Rezeptoren mittels Single-Photon-Emissions-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Paulik, Dagmar Julia

    2015-03-06

    For the synthesis of [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine (nACh) receptors using SPECT two different technologies were used: the radio-iodination with iodogen and the radio-iodination with nitric acid. The latter one showed higher efficiency. The radiotracer will allow to detect degenerative processes and other nACh-depending diseases in the brain (Alzheimer, Parkinson) and to observe the progress. The autoradiography is aimed to the imaging of the nACh receptors in the brain bypassing the brain-blood barrier. The highest activity was measured in the thalamus of mice and rat brains.

  14. Application of radiotracer technology to the study of coastal processes

    International Nuclear Information System (INIS)

    Airey, P.; Szymczak, R.; Zaw, M.; Tu, J.; Kluss, T.; Barry, J.

    1999-01-01

    Recent progress at ANSTO in the applications of radiotracer techniques to the study of coastal processes is reviewed. Tracers are used in detailed studies of specific components of complex environmental systems and are applied to the evaluation and extension of numerical models. Examples include studies of the aggregation of sewage particles following release from ocean outfalls. The use of tracers to study the impact of storm events on bedload transport at depth has also been demonstrated

  15. 10 CFR 71.71 - Normal conditions of transport.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Normal conditions of transport. 71.71 Section 71.71 Energy..., Special Form, and LSA-III Tests 2 § 71.71 Normal conditions of transport. (a) Evaluation. Evaluation of each package design under normal conditions of transport must include a determination of the effect on...

  16. Study of regional pulmonary gas exchange using radiotracers

    International Nuclear Information System (INIS)

    Hichwa, R.D.

    1981-01-01

    Respiration involves the exchange of gases between the environment and the blood across the alveolar membrane. Four processes characterize the dynamics of gas exchange: ventilation, diffusion, perfusion and chemical binding with hemoglobin. A study was undertaken to investigate each of these processes, utilizing accelerator production and high yield synthesis of four gaseous radiotracers (/sup 81m/Kr, Ch 3 18 F, 11 CO, 15 O 2 ). Conventional gamma camera images and ancillary physiological data were acquired. Mathematical models were developed to predict the tracer clearance from the lungs during a breath hold and during washout post breath hold. Images of the insoluble /sup 81m/Kr synchronized with the tidal breathing maneuver depict regional ventilation. Tracer bolus inhalation, relative compliance and regional phase information are obtained from krypton dCynamic studies. More soluble CH 3 18 F is used to determine regional pulmonary perfusion during a breath hold. Respiratory clearance of seven, inert, positron-emitting radiotracers define the tracer volume of distribution. The tight-binding of 11 CO to hemoglobin permits the regional measurement of carbon monoxide pulmonary diffusion capacity. A relative CO blood:gas partition coefficient is calculated from the washout of no-carrier-added levels of 11 CO and verified by in vitro radiometric measurements. Regional oxygen pulmonary diffusion capacity determined from 15 O 2 clearance during a breath hold reveals results similar to those obtained with CO. All experimental data are in good agreement with the predictions of a two-compartment open model. A more advanced oxygen model is presented that incorporates radioactive oxygen exchange with stable oxygen on the hemoglobin molecule and metabolic removal of the tracer at the tissues

  17. Novel methodology for the study of mercury methylation and reduction in sediments and water using 197Hg radiotracer

    International Nuclear Information System (INIS)

    Ribeiro Guevara, Sergio; Perez Catan, Soledad; Zizek, Suzana; Repinc, Urska; Jacimovic, Radojko; Horvat, Milena

    2007-01-01

    Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H 2 SO 4 or HCl were evaluated in freshwater sediments using 197 Hg radiotracer. Values obtained for the 197 Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of 197 Hg 2+ into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg 2+ contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg 2+ contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H 2 SO 4 method is recommended, since it is free from these interferences. 197 Hg radiotracer (T 1/2 = 2.673 d) has a production rate that is about 50 times higher than that of 203 Hg (T 1/2 46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to 203 Hg when it is used it in short-term experiments and produced by the irradiation of 196 Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the 196 Hg isotope is increased, the specific activity of the 197 Hg tracer can be significantly improved. In the present work, 197 Hg tracer was produced from mercury 51.58% enriched in the 196 Hg

  18. Study on inclusive production of Δ++ and Δ0 isobars in K-p interactions at 32 GeV/c

    International Nuclear Information System (INIS)

    Babintsev, V.V.; Bogolyubskij, M.Yu.; Bumazhnov, V.A.

    1984-01-01

    Properties of inclusive production of Δ ++ and Δ 0 isobars are studied using the total statistics (approximately 1.15x10 5 inelastic interactions) of the K - p experiment at 32 GeV/c. It is found that the Δ ++ and Δ 0 inclusive production cross sections are σ(Δ ++ )=1.71+-0.14 mb, σ(Δ 0 )=1.27+-0.25 mb. Some production differential cross sections for those isobars are reconstructed. Angular characteristics of Δ ++ decay are considered. It is shown that the principel part of the Δ ++ - and Δ 0 - isobars is produced peripherally (x ++ and Δ 0 distributions coincide in the main, which indicates that the same mechanism is controlling the isobar production

  19. Pulse shape discrimination performance of inverted coaxial Ge detectors

    Science.gov (United States)

    Domula, A.; Hult, M.; Kermaïdic, Y.; Marissens, G.; Schwingenheuer, B.; Wester, T.; Zuber, K.

    2018-05-01

    We report on the characterization of two inverted coaxial Ge detectors in the context of being employed in future 76Ge neutrinoless double beta (0 νββ) decay experiments. It is an advantage that such detectors can be produced with bigger Ge mass as compared to the planar Broad Energy Ge (BEGe) or p-type Point Contact (PPC) detectors that are currently used in the GERDA and MAJORANA DEMONSTRATOR 0 νββ decay experiments respectively. This will result in a lower background for the search of 0 νββ decay due to a reduction of detector surface to volume ratio, cables, electronics and holders which are dominating nearby radioactive sources. The measured resolution near the 76Ge Q-value at 2039 keV is 2.3 keV FWHM and their pulse-shape discrimination of background events are similar to BEGe and PPC detectors. It is concluded that this type of Ge-detector is suitable for usage in 76Ge 0 νββ decay experiments.

  20. Investigation of sediment transport and optimization of dredging operations in Indian ports using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.

    2012-01-01

    India has a long coastline of about 7,515 km and there are twelve major ports situated on the coastline. Out of them, six are situated on the West Coast whereas other six are situated on the East Coast. In addition to this, there are more than 140 minor ports and other marine establishments situated along the coastline. Each port and marine project has a navigation channel and depth of this navigation channel needs to be maintained to a level of at least 12-15 meters for smooth sailing of ships. Sediments continuously move along the coast due to alongshore currents generated by the waves and tides; and get deposited in navigation channels. For maintaining the required depth of the channels, the dredging operation is carried out. throughout the year or as and when required. Development of a new port or harbour also involves huge capital dredging. The dredged sediments generated during maintenance or capital dredging needs to be dumped at a suitable location, so that it does not find its way back to the channel and obstruct sailing of ships. Moreover the selected site should be such that the turn around time of the dredger is kept minimum to economize the dredging operation. In order to meet the above requirements, the knowledge of transport parameters such as the general direction of movement, extent of lateral and longitudinal movement, transport velocity, transport thickness and bed load movement rate is required. Radiotracer techniques are commonly used to investigate sediment transport on seabed and evaluate the suitability of the proposed dumping sites. Scandium-46 (half-life: 84 days, Gamma energies: 0.89 MeV (100%), 1.12 MeV (100%)) in the form of scandium glass powder is the most suitable radiotracer for tracing sediments on seabed. The activity used in an investigation ranges from 75-300 GBq (2-8 Ci). The suitably prepared particulate radiotracer is injected on seabed at the proposed site using a specially designed injection system and its movement is

  1. Nb3Ge superconductive films grown with nitrogen

    International Nuclear Information System (INIS)

    Sigsbee, R.A.

    1978-01-01

    A superconductive film of Nb 3 Ge is produced by providing within a vacuum chamber a heated substrate and sources of niobium and germanium, reducing the pressure within the chamber to a residual pressure no greater than about 10 -5 mm Hg, introducing nitrogen into the resulting evacuated chamber in controlled amounts and vaporizing the niobium and germanium to deposit a film of Nb 3 Ge on the heated substrate

  2. Study on ancient Chinese imitated GE ware by INAA and WDXRF

    International Nuclear Information System (INIS)

    Xie Guoxi; Feng Songlin; Feng Xiangqian; Wang Yanqing; Zhu Jihao; Yan Lingtong; Li Yongqiang; Han Hongye

    2007-01-01

    Imitated GE ware was one of the most famous products of Jingdezhen porcelain field in Ming dynasty (AD 1368-1644). The exterior features of its body and glaze are very marvelous. Black foot, purple mouth and crazing glaze are the main features of imitated GE ware. Until now, the key conditions of resulting these features are not clearly identified. In order to find the critical elements for firing these features, instrumental neutron activation analysis (INAA) and wavelength-dispersive X-ray fluorescence (WDXRF) were used to determine the element abundance patterns of imitated GE ware body and glaze. The experimental data was compared with that of imitated Longquan celadon and of Longquan celadon. The analytical results indicated that Fe, Ti and Na were the critical elements. The body of imitated GE ware which contains high Fe and Ti are the basic conditions of firing its black body, black foot and purple mouth. The glaze of imitated GE ware which contains high Na is the main condition of producing its crazing glaze. Na is the critical element which enlarges the difference in expansion coefficients between the glaze and body of imitated GE ware. Furthermore, Zijin soil was added into kaolin to make the body rich in Fe and Ti. And something which was rich in Na was used to produce crazing glaze in the manufacturing process of imitated GE ware

  3. Study on ancient Chinese imitated GE ware by INAA and WDXRF

    Science.gov (United States)

    Xie, Guoxi; Feng, Songlin; Feng, Xiangqian; Wang, Yanqing; Zhu, Jihao; Yan, Lingtong; Li, Yongqiang; Han, Hongye

    2007-11-01

    Imitated GE ware was one of the most famous products of Jingdezhen porcelain field in Ming dynasty (AD 1368-1644). The exterior features of its body and glaze are very marvelous. Black foot, purple mouth and crazing glaze are the main features of imitated GE ware. Until now, the key conditions of resulting these features are not clearly identified. In order to find the critical elements for firing these features, instrumental neutron activation analysis (INAA) and wavelength-dispersive X-ray fluorescence (WDXRF) were used to determine the element abundance patterns of imitated GE ware body and glaze. The experimental data was compared with that of imitated Longquan celadon and of Longquan celadon. The analytical results indicated that Fe, Ti and Na were the critical elements. The body of imitated GE ware which contains high Fe and Ti are the basic conditions of firing its black body, black foot and purple mouth. The glaze of imitated GE ware which contains high Na is the main condition of producing its crazing glaze. Na is the critical element which enlarges the difference in expansion coefficients between the glaze and body of imitated GE ware. Furthermore, Zijin soil was added into kaolin to make the body rich in Fe and Ti. And something which was rich in Na was used to produce crazing glaze in the manufacturing process of imitated GE ware.

  4. Study on ancient Chinese imitated GE ware by INAA and WDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Xie Guoxi [Institute of High Energy Physics, Chinese Academy of Sciences, 19 Yu Quan Lu, Beijing 100049 (China); Graduated University of Chinese Academy of Sciences, Beijing 100049 (China); Feng Songlin [Institute of High Energy Physics, Chinese Academy of Sciences, 19 Yu Quan Lu, Beijing 100049 (China)], E-mail: fengsl@ihep.ac.cn; Feng Xiangqian; Wang Yanqing; Zhu Jihao; Yan Lingtong [Institute of High Energy Physics, Chinese Academy of Sciences, 19 Yu Quan Lu, Beijing 100049 (China); Li Yongqiang; Han Hongye [Beijing Institute of Cultural Relics, Beijing 100009 (China)

    2007-11-15

    Imitated GE ware was one of the most famous products of Jingdezhen porcelain field in Ming dynasty (AD 1368-1644). The exterior features of its body and glaze are very marvelous. Black foot, purple mouth and crazing glaze are the main features of imitated GE ware. Until now, the key conditions of resulting these features are not clearly identified. In order to find the critical elements for firing these features, instrumental neutron activation analysis (INAA) and wavelength-dispersive X-ray fluorescence (WDXRF) were used to determine the element abundance patterns of imitated GE ware body and glaze. The experimental data was compared with that of imitated Longquan celadon and of Longquan celadon. The analytical results indicated that Fe, Ti and Na were the critical elements. The body of imitated GE ware which contains high Fe and Ti are the basic conditions of firing its black body, black foot and purple mouth. The glaze of imitated GE ware which contains high Na is the main condition of producing its crazing glaze. Na is the critical element which enlarges the difference in expansion coefficients between the glaze and body of imitated GE ware. Furthermore, Zijin soil was added into kaolin to make the body rich in Fe and Ti. And something which was rich in Na was used to produce crazing glaze in the manufacturing process of imitated GE ware.

  5. The application of radiotracer technique for preconcentration neutron activation analysis

    International Nuclear Information System (INIS)

    Wang Xiaolin; Chen Yinliang; Sun Ying; Fu Yibei

    1995-01-01

    The application of radiotracer technique for preconcentration neutron activation analysis (Pre-NAA) are studied and the method for determination of chemical yield of Pre-NAA is developed. This method has been applied to determination of gold, iridium and rhenium in steel and rock samples and the contents of noble metal are in the range of 1-20 ng·g -1 (sample). In addition, the accuracy difference caused by determination of chemical yield between RNAA and Pre-NAA are also discussed

  6. Search for excited leptons in $e^{+} e^{-}$ annihilation at $\\sqrt {s}$ = 130 - 140 GeV

    CERN Document Server

    Acciarri, M; Adriani, O; Aguilar-Benítez, M; Ahlen, S P; Alpat, B; Alcaraz, J; Allaby, James V; Aloisio, A; Alverson, G; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Antreasyan, D; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Ball, R C; Banerjee, S; Banicz, K; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Bencze, G L; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Borgia, B; Boucham, A; Bourilkov, D; Bourquin, Maurice; Boutigny, D; Brambilla, Elena; Branson, J G; Brigljevic, V; Brock, I C; Buijs, A; Bujak, A T; Burger, J D; Burger, W J; Burgos, C; Busenitz, J K; Buytenhuijs, A O; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Caria, M; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Castello, R; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chan, A; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, C; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chéreau, X J; Chiefari, G; Chien, C Y; Choi, M T; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Coan, T E; Cohn, H O; Coignet, G; Colijn, A P; Colino, N; Commichau, V; Costantini, S; Cotorobai, F; de la Cruz, B; Dai, T S; D'Alessandro, R; De Asmundis, R; De Boeck, H; Degré, A; Deiters, K; Dénes, E; Denes, P; De Notaristefani, F; DiBitonto, Daryl; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dorne, I; Dova, M T; Drago, E; Duchesneau, D; Duinker, P; Durán, I; Dutta, S; Easo, S; Efremenko, Yu V; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabbretti, R; Fabre, M; Faccini, R; Falciano, S; Favara, A; Fay, J; Felcini, Marta; Ferguson, T; Fernández, D; Fernández, G; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Forconi, G; Fredj, L; Freudenreich, Klaus; Gailloud, M; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gau, S S; Gentile, S; Gerald, J; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; González, E; Gougas, Andreas; Goujon, D; Gratta, Giorgio; Grünewald, M W; Gupta, V K; Gurtu, A; Gustafson, H R; Gutay, L J; Hangarter, K; Hartmann, B; Hasan, A; He, J T; Hebbeker, T; Hervé, A; Van Hoek, W C; Hofer, H; Hoorani, H; Hou, S R; Hu, G; Ilyas, M M; Innocente, Vincenzo; Janssen, H; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamyshkov, Yu A; Kapinos, P; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kim, S C; Kim, Y G; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kittel, E W; Klimentov, A; König, A C; Koffeman, E; Köngeter, A; Koutsenko, V F; Koulbardis, A; Krämer, R W; Kramer, T; Krenz, W; Kuijten, H; Kunin, A; Ladrón de Guevara, P; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee Jae Sik; Lee, K Y; Leggett, C; Le Goff, J M; Leiste, R; Lenti, M; Leonardi, E; Levchenko, P M; Li Chuan; Lieb, E H; Lin, W T; Linde, Frank L; Lindemann, B; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Ludovici, L; Luminari, L; Lustermann, W; Ma Wen Gan; Macchiolo, A; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangla, S; Maolinbay, M; Marchesini, P A; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; Mazumdar, K; McNally, D; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Mi, Y; Mihul, A; Van Mil, A J W; Mirabelli, G; Mnich, J; Möller, M; Monteleoni, B; Moore, R; Morganti, S; Mount, R; Müller, S; Muheim, F; Nagy, E; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nippe, A; Nowak, H; Organtini, G; Ostonen, R; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Pinto, J C; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Produit, N; Raghavan, R; Rahal-Callot, G; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Read, K; Redaelli, M; Ren, D; Rescigno, M; Reucroft, S; Ricker, A; Riemann, S; Riemers, B C; Riles, K; Rind, O; Ro, S; Robohm, A; Rodin, J; Rodríguez-Calonge, F J; Roe, B P; Röhner, S; Romero, L; Rosier-Lees, S; Rosselet, P; Van Rossum, W; Roth, S; Rubio, Juan Antonio; Rykaczewski, H; Salicio, J; Salicio, J M; Sánchez, E; Santocchia, A; Sarakinos, M E; Sarkar, S; Sassowsky, M; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schmitz, P; Schneegans, M; Schöneich, B; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schulte, R; Schultze, K; Schwenke, J; Schwering, G; Sciacca, C; Seiler, P G; Sens, Johannes C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Siedenburg, T; Son, D; Sopczak, André; Soulimov, V; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Sticozzi, F; Stone, H; Stoyanov, B; Strässner, A; Strauch, K; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Ting, Samuel C C; Ting, S M; Toker, O; Tonisch, F; Tonutti, M; Tonwar, S C; Tóth, J; Tsaregorodtsev, A Yu; Tully, C; Tuchscherer, H; Tung, K L; Ulbricht, J; Urbàn, L; Uwer, U; Valente, E; Van de Walle, R T; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Völkert, R; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vuilleumier, L; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Y F; Wang, Z M; Weber, A; Weill, R; Willmott, C; Wittgenstein, F; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yao, X Y; Ye, J B; Yeh, S C; You, J M; Zaccardelli, C; Zalite, A; Zemp, P; Zeng, J Y; Zeng, Y; Zhang, Z; Zhang, Z P; Zhou, B; Zhou, G J; Zhou, Y; Zhu, G Y; Zhu, R Y; Zichichi, Antonino; Van der Zwaan, B C C

    1996-01-01

    We report on a search for the excited leptons e^*,mu^*,tau^* and nu^* in e+e- collisions at sqrt{s} = 130 - 140 GeV using the L3 detector at LEP. No evidence has been found for their existence. From an analysis of the expected pair produced l^*l^* in the channels e.e.gamma.gamma, mu.mu.gamma.gamma, tau.tau.gamma.gamma, eeWW, and nu.nu.gamma.gamma, we determine the lower mass limits at 95% C.L. of 64.7 GeV for e^*, 64.9 GeV for mu^*, 64.2 GeV for tau*, 57.3 GeV ( eW decay mode) and 61.4 GeV ( nu.gamma decay mode) for nu^*. From an analysis of the expected singly produced l.l^* in the channels e.e.gamma, mu.mu.gamma, tau.tau.gamma, nu.eW and nu.nu.gamma, we determine upper limits on the couplings lambda/m_{l^*} up to m_{l^*} = 130 GeV.

  7. Determination of the particle size distribution in a powder using radiotracers

    International Nuclear Information System (INIS)

    Revilla D, R.

    1974-01-01

    To determine experimentally the particle size distribution in a powder the meshed method is generally used. This method has the disadvantage that in the obtained distribution is not observed at detail the fine structure of such distribution. In this work, a method for obtaining the distribution of particle size using radiotracers is presented. In the obtained distribution by this method it is observed with more detail the fine structure of the distribution, comparing with the obtained results by the classical method of meshed. The radiotracer method has major resolution for the experimental determination mentioned. In the chapter 1, it is done a brief analysis about theoretical aspects related with the method. In the first part it is analysed the particle behavior (sedimenting) in a fluid. The second part treats the relating with the radioactivity of an activated material as well as its detection. In the chapter 2, a description of the method is done also the experimental problems to applying to the alumina crystals sample are discussed. In the chapter 3 the obtained results and the mistake calculations in such results are showed. Finally, in the chapter 4 the conclusions and recommendations are given which is possible to obtain better results and improve to those in this work were obtained. (Author)

  8. Superthin Solar Cells Based on AIIIBV/Ge Heterostructures

    Science.gov (United States)

    Pakhanov, N. A.; Pchelyakov, O. P.; Vladimirov, V. M.

    2017-11-01

    A comparative analysis of the prospects of creating superthin, light-weight, and highly efficient solar cells based on AIIIBV/InGaAs and AIIIBV/Ge heterostructures is performed. Technological problems and prospects of each variant are discussed. A method of thinning of AIIIBV/Ge heterostructures with the use of an effective temporary carrier is proposed. The method allows the process to be performed almost with no risk of heterostructure fracture, thinning of the Ge junction down to several tens of micrometers (or even several micrometers), significant enhancement of the yield of good structures, and also convenient and reliable transfer of thinned solar cells to an arbitrary light and flexible substrate. Such a technology offers a possibility of creating high-efficiency thin and light solar cells for space vehicles on the basis of mass-produced AIIIBV/Ge heterostructures.

  9. Synthesis and characterization of Ge–Cr-based intermetallic compounds: GeCr3, GeCCr3, and GeNCr3

    International Nuclear Information System (INIS)

    Lin, S.; Tong, P.; Wang, B.S.; Huang, Y.N.; Song, W.H.; Sun, Y.P.

    2014-01-01

    Highlights: • Polycrystalline samples of GeCr 3 , GeCCr 3 , and GeNCr 3 are synthesized by using solid state reaction method. • A good quality of our samples is verified by the Rietveld refinement and electrical transport measurement. • We present a comprehensive understanding of physical properties of GeCr 3 , GeCCr 3 , and GeNCr 3 . -- Abstract: We report the synthesis of GeCr 3 , GeCCr 3 , and GeNCr 3 polycrystalline compounds, and present a systematic study of this series by the measurements of X-ray diffraction (XRD), magnetism, electrical/thermal transport, specific heat, and Hall coefficient. Good quality of our samples is verified by quite small value of residual resistivity and considerably large residual resistivity ratio. Based on the Rietveld refinement of XRD data, the crystallographic parameters are obtained, and, correspondingly, the sketches of crystal structure are plotted for all the samples. The ground states of GeCr 3 , GeCCr 3 , and GeNCr 3 are paramagnetic/antiferromagnetic metal, and even a Fermi-liquid behavior is observed in electrical transport at low temperatures. Furthermore, the analysis of the thermal conductivity data suggests the electron thermal conductivity plays a major role in total thermal conductivity for GeCr 3 at low temperatures, while the phonon thermal conductivity is dominant for GeCCr 3 and GeNCr 3 at high temperatures. The negative value of Seebeck coefficient and Hall coefficient indicate that the charge carriers are electron-type for GeCr 3 , GeCCr 3 , and GeNCr 3

  10. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    International Nuclear Information System (INIS)

    Sugiharto, S.; Kurniadi, R.; Abidin, Z.; Stegowski, Z.; Furman, L.

    2013-01-01

    Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT) having an inner diameter of 24 in (60,96 m). The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD) curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD) simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct. (author)

  11. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    Directory of Open Access Journals (Sweden)

    S. Sugiharto1

    2013-04-01

    Full Text Available Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT having an inner diameter of 24 in (60,96 m. The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct

  12. Immunological Evaluation and Comparison of Different EV71 Vaccine Candidates

    Directory of Open Access Journals (Sweden)

    Ai-Hsiang Chou

    2012-01-01

    Full Text Available Enterovirus 71 (EV71 and coxsackievirus A16 (CVA16 are major causative agents of hand, foot, and mouth diseases (HFMDs, and EV71 is now recognized as an emerging neurotropic virus in Asia. Effective medications and/or prophylactic vaccines against HFMD are not available. The current results from mouse immunogenicity studies using in-house standardized RD cell virus neutralization assays indicate that (1 VP1 peptide (residues 211–225 formulated with Freund’s adjuvant (CFA/IFA elicited low virus neutralizing antibody response (1/32 titer; (2 recombinant virus-like particles produced from baculovirus formulated with CFA/IFA could elicit good virus neutralization titer (1/160; (3 individual recombinant EV71 antigens (VP1, VP2, and VP3 formulated with CFA/IFA, only VP1 elicited antibody response with 1/128 virus neutralization titer; and (4 the formalin-inactivated EV71 formulated in alum elicited antibodies that cross-neutralized different EV71 genotypes (1/640, but failed to neutralize CVA16. In contrast, rabbits antisera could cross-neutralize strongly against different genotypes of EV71 but weakly against CVA16, with average titers 1/6400 and 1/32, respectively. The VP1 amino acid sequence dissimilarity between CVA16 and EV71 could partially explain why mouse antibodies failed to cross-neutralize CVA16. Therefore, the best formulation for producing cost-effective HFMD vaccine is a combination of formalin-inactivated EV71 and CAV16 virions.

  13. FUEL CONTAMINATION IN A MARINE DIESEL ENGINE. A RADIOTRACER STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, B. E.

    1964-04-15

    A radiotracer method was applied to the problem of elucidating the mechanism of contamination of crankcase oil by fuel combustion products in a marine diesel engine. The method consisted of adding an oil soluble radioisotope to the fuel and tracing its route to the various lubricants used in the engine. It was found that of the total amount of combustion products and by-products which enter the crankcase oil, 65% enters by simple contamination via reintroduction of used cylinder lubricant and 35% by a condensation mechanism. (auth)

  14. Radiotracer aided optimization of batch mixing of solids

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Bergh, W.J.B. van den; Scarlett, B.

    1989-01-01

    A method for the determination of mixing times has been developed and tested in a model Nauta mixer filled with sand. 128 I-labelled sand particles were used as radiotracer and the progress of mixing was monitored with two radiation detectors located externally. The variance of the radiation intensity decreases with time until a constant value is reached indicating an equilibrium mixture of tracer and sand. The time necessary to achieve this condition (mixing time) appears to be dependent on the rotational speed of the hopper as well as the screw of the mixer. Optimal mixing performance (shortest mixing time) corresponds to the maximal rotational speeds of both rotating parts of the mixer. (author)

  15. Structure determination of enterovirus 71

    Energy Technology Data Exchange (ETDEWEB)

    Plevka, Pavel; Perera, Rushika; Cardosa, Jane; Kuhn, Richard J.; Rossmann, Michael G. (Purdue); (Sentinext)

    2013-02-20

    Enterovirus 71 is a picornavirus that causes hand, foot and mouth disease but may induce fatal neurological illness in infants and young children. Enterovirus 71 crystallized in a body-centered orthorhombic space group with two particles in general orientations in the crystallographic asymmetric unit. Determination of the particle orientations required that the locked rotation function excluded the twofold symmetry axes from the set of icosahedral symmetry operators. This avoided the occurrence of misleading high rotation-function values produced by the alignment of icosahedral and crystallographic twofold axes. Once the orientations and positions of the particles had been established, the structure was solved by molecular replacement and phase extension.

  16. Preparation and investigation of Ge-S-I glasses for infrared fiber optics

    Science.gov (United States)

    Velmuzhov, A. P.; Sukhanov, M. V.; Plekhovich, A. D.; Snopatin, G. E.; Churbanov, M. F.; Iskhakova, L. D.; Ermakov, R. P.; Kotereva, T. V.; Shiryaev, V. S.

    2016-02-01

    Glass samples of [GeSx]90I10 (x = 1.5, 1.7, 2.0, 2.3, 2.45, 2.6) compositions were prepared, and some their thermal, optical properties as well as tendency to crystallization were investigated. The compositional dependences of glass transition temperature, volume fraction of crystallized phase and activation energy of glass formation (Eg) have nonmonotonic character with a maximum for [GeS2.0]90I10 glass. Glasses of 85.8GeS2-14.2GeI4 and [GeS1.5]90I10 compositions are identified as promising for preparation of optical fiber. For the first time, Ge-S-I glass fibers were produced. Minimum optical losses in 85.8GeS2-14.2GeI4 glass fiber were 2.7 dB/m at a wavelength of 5.1 μm, and that in [GeS1.5]90I10 glass fiber were 14.5 dB/m at 5.5 μm.

  17. Single-fabrication-step Ge nanosphere/SiO2/SiGe heterostructures: a key enabler for realizing Ge MOS devices

    Science.gov (United States)

    Liao, P. H.; Peng, K. P.; Lin, H. C.; George, T.; Li, P. W.

    2018-05-01

    We report channel and strain engineering of self-organized, gate-stacking heterostructures comprising Ge-nanosphere gate/SiO2/SiGe-channels. An exquisitely-controlled dynamic balance between the concentrations of oxygen, Si, and Ge interstitials was effectively exploited to simultaneously create these heterostructures in a single oxidation step. Process-controlled tunability of the channel length (5–95 nm diameters for the Ge-nanospheres), gate oxide thickness (2.5–4.8 nm), as well as crystal orientation, chemical composition and strain engineering of the SiGe-channel was achieved. Single-crystalline (100) Si1‑x Ge x shells with Ge content as high as x = 0.85 and with a compressive strain of 3%, as well as (110) Si1‑x Ge x shells with Ge content of x = 0.35 and corresponding compressive strain of 1.5% were achieved. For each crystal orientation, our high Ge-content, highly-stressed SiGe shells feature a high degree of crystallinity and thus, provide a core ‘building block’ required for the fabrication of Ge-based MOS devices.

  18. Measurement of Pion and Kaon Fluxes Below 60 GeV/c Produced by 450~GeV/c Protons on a Beryllium Target The SPY Collaboration

    CERN Multimedia

    2002-01-01

    % NA56 \\\\ \\\\ We propose to perform a measurement of the production rates of $\\pi$'s and K's and their ratio below 60~GeV/c from 450~GeV/c protons hitting a Be target. These data are of great importance for the correct evaluation of the neutrino flux at the present and future SPS neutrino experiments. The apparatus of the NA52 experiment has the capability of performing the measurement, using about two weeks of proton beam time and a target closely resembling the one used in the current SPS neutrino beam line.

  19. Optical and structural characterization of Ge clusters embedded in ZrO2

    OpenAIRE

    Agocs, E; Zolnai, Z.; Rossall, A. K.; Van den Berg, Jakob; Fodor, B.; Lehninger, D.; Khomenkova, L.; Ponomaryov, S.; Gudymenko, O.; Yukhymchuk, V.; Kalas, B.; Heitmann, J.; Petrik, P.

    2017-01-01

    The change of optical and structural properties of Ge nanoclusters in ZrO2 matrix have been investigated by spectroscopic ellipsometry versus annealing temperatures. Radio-frequency top-down magnetron sputtering approach was used to produce the samples of different types, i.e. single-layers of pure Ge, pure ZrO2 and Ge-rich-ZrO2 as well as multi-layers stacked of 40 periods of 5-nm-Ge-rich-ZrO2 layers alternated by 5-nm-ZrO2 ones. Germanium nanoclusters in ZrO2 host were formed by rapid-therm...

  20. A Study of High Transverse Momentum Electrons Produced in pp Collisions at 540 GeV

    DEFF Research Database (Denmark)

    Bagnaia, P; Kofoed-Hansen, O.

    1984-01-01

    The production of electrons with very high transverse momentum has been studied in the UA2 experiment at the CERN [`(p)]ppp collider ( Öss =540 GeV). From a sample of events containing an electron candidate withp T >15 GeV/c, we extract a clear signal resulting from the production of the charged...... intermediate vector bosonW ±, which subsequently decays into an electron and a neutrino. We study theW production and decay properties. Further-more, we refine our results on the production and decay of the neutral vector bosonZ 0. Finally, we compare the experimental results to the predictions of the standard...

  1. Effect of Ge Content on the Formation of Ge Nanoclusters in Magnetron-Sputtered GeZrOx-Based Structures.

    Science.gov (United States)

    Khomenkova, L; Lehninger, D; Kondratenko, O; Ponomaryov, S; Gudymenko, O; Tsybrii, Z; Yukhymchuk, V; Kladko, V; von Borany, J; Heitmann, J

    2017-12-01

    Ge-rich ZrO 2 films, fabricated by confocal RF magnetron sputtering of pure Ge and ZrO 2 targets in Ar plasma, were studied by multi-angle laser ellipsometry, Raman scattering, Auger electron spectroscopy, Fourier transform infrared spectroscopy, and X-ray diffraction for varied deposition conditions and annealing treatments. It was found that as-deposited films are homogeneous for all Ge contents, thermal treatment stimulated a phase separation and a formation of crystalline Ge and ZrO 2 . The "start point" of this process is in the range of 640-700 °C depending on the Ge content. The higher the Ge content, the lower is the temperature necessary for phase separation, nucleation of Ge nanoclusters, and crystallization. Along with this, the crystallization temperature of the tetragonal ZrO 2 exceeds that of the Ge phase, which results in the formation of Ge crystallites in an amorphous ZrO 2 matrix. The mechanism of phase separation is discussed in detail.

  2. Fabrication of multilayered Ge nanocrystals embedded in SiOxGeNy films

    International Nuclear Information System (INIS)

    Gao Fei; Green, Martin A.; Conibeer, Gavin; Cho, Eun-Chel; Huang Yidan; Perez-Wurfl, Ivan; Flynn, Chris

    2008-01-01

    Multilayered Ge nanocrystals embedded in SiO x GeN y films have been fabricated on Si substrate by a (Ge + SiO 2 )/SiO x GeN y superlattice approach, using a rf magnetron sputtering technique with a Ge + SiO 2 composite target and subsequent thermal annealing in N 2 ambient at 750 deg. C for 30 min. X-ray diffraction (XRD) measurement indicated the formation of Ge nanocrystals with an average size estimated to be 5.4 nm. Raman scattering spectra showed a peak of the Ge-Ge vibrational mode downward shifted to 299.4 cm -1 , which was caused by quantum confinement of phonons in the Ge nanocrystals. Transmission electron microscopy (TEM) revealed that Ge nanocrystals were confined in (Ge + SiO 2 ) layers. This superlattice approach significantly improved both the size uniformity of Ge nanocrystals and their uniformity of spacing on the 'Z' growth direction

  3. The future machine with electrons of 15-30 GeV

    International Nuclear Information System (INIS)

    Tkatchenko, A.

    1992-01-01

    This article presents the project of european linear accelerator with a continuous beam of high energy electrons for the Nuclear Physics researches. Based on a superconducting linear accelerator crossed several times, this machine will be able to produce beams of 15 GeV in a first time, then 30 GeV, by increasing of accelerator cavity field without modifying the beam circulation system

  4. Investigation of the operational quality of germanium gamma detectors. Estimation of Ge:Li detector survival rates

    International Nuclear Information System (INIS)

    Zerbib, J.-C.

    1980-01-01

    A working group has produced tables of information on gamma semiconductor Ge detectors: Ge(Li) or intrinsic Ge. The information was obtained as a result of enquirres addressed to various laboratories, and concerns 228-sources in France and Belgium [fr

  5. Structure of 78Ge from the 76Ge(t,p)78Ge reaction

    International Nuclear Information System (INIS)

    Ardouin, D.; Lebrun, C.; Guilbault, F.; Remaud, B.; Vergnes, M.N.; Rotbard, G.; Kumar, K.

    1978-01-01

    The 76 Ge(t,p) 78 Ge reaction has been performed at a bombarding energy of 17 MeV. Thirteen excited states below 3 MeV excitation are reported with Jsup(π) values obtained by comparison to DWBA analysis. A comparison to a dynamical deformation theory is made and the results suggest 78 Ge is a transitional nucleus nearing spherical shape due to the proximity of the N-50 closed shell

  6. Multiple collision effects on the antiproton production by high energy proton (100 GeV - 1000 GeV)

    International Nuclear Information System (INIS)

    Takahashi, Hiroshi; Powell, J.

    1987-01-01

    Antiproton production rates which take into account multiple collision are calculated using a simple model. Methods to reduce capture of the produced antiprotons by the target are discussed, including geometry of target and the use of a high intensity laser. Antiproton production increases substantially above 150 GeV proton incident energy. The yield increases almost linearly with incident energy, alleviating space charge problems in the high current accelerator that produces large amounts of antiprotons

  7. γ-Oryzanol, tocol and mineral compositions in different grain fractions of giant embryo rice mutants.

    Science.gov (United States)

    Jeng, Toong Long; Shih, Yi Ju; Ho, Pei Tzu; Lai, Chia Chi; Lin, Yu Wen; Wang, Chang Sheng; Sung, Jih Min

    2012-05-01

    Rice embryo is concentrated with lipid, protein and some bioactive chemicals. Two rice mutants IR64-GE and TNG71-GE (M7 generation) were characterised by an enlarged embryo compared with their wild types. In the present study, distributions of protein, lipid, total phenolics, γ-oryzanol, tocols and some essential minerals in these two giant embryo mutants and their respective normal embryo wild types IR64 and TNG71 were compared. The embryo dry weights of giant embryo mutants IR64-GE and TNG71-GE were 0.92 and 1.32 mg per seed respectively. These values were higher than those of their respective normal embryo genotypes (0.50 and 0.62 mg per seed). Large variations in protein, lipid, phenolic, γ-oryzanol, tocol and minerals levels were found between mutant and wild-type pairs. The brown rice of TNG71-GE had higher total γ-oryzanol (average of 24% increase) and total tocol (average of 75% increase) levels than TNG71, IR64 and IR64-GE. The embryo and bran parts of giant embryo mutant TNG71-GE were found to be good sources of vitamin E and γ-oryzanol. Therefore it could be used to produce high-value by-products from milled embryo and bran parts and as a genetic resource for rice improvement programmes. TNG71-GE can also be used as a nutrient-fortified rice cultivar. Copyright © 2011 Society of Chemical Industry.

  8. Biological distribution of [{sup 18}F-FDG] using reactor produced [{sup 18}F]; Distribucion biologica del {sup 18}F-Fluordeoxiglucosa utilizando [{sup 18}F] producido en reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, P; Massardo, T [Centro de Medicina Nuclear. Hospital Clinico Universidad de Chile, Santiago (Chile); Gil, M C [CGM Nuclear, Santiago (Chile); Gonzalez, P [Centro de Medicina Nuclear. Hospital Clinico Universidad de Chile, Santiago (Chile); Chandia, M; Godoy, N; Troncoso, F [Comision Chilena de Energia Nuclear, Cen La Reina, Santiago (Chile)

    2002-12-01

    The animal model that relates biodistribution of a substance is fundamental prior to using it in human beings. For the evaluation of myocardial viability after a recent MI, the use of reactor produced [{sup 18}F]-FDG (a radiotracer usually obtained in Cyclotron) is proposed, production of which has never been attempted in our country. Specific Activities founded in the different tissues after injection of this radiotracer in an animal model were compared with those obtained by other authors with cyclotron [{sup 18}F]-FDG. No statistically significant differences in the critical organs were found. Hence, reactor produced [{sup 18}F]-FDG is a useful radiopharmaceutical in cardiac cellular metabolism assessment (author)

  9. Imaging in hearing using radiotracers

    Directory of Open Access Journals (Sweden)

    Berding Georg

    2017-09-01

    Full Text Available Radiotracers offer unique options for brain imaging of functional and molecular processes related to hearing. Such imaging can be applied in a broad spectrum of situations from preclinical research to clinical patient care. Functional imaging to assess activation in brain regions and networks involved in auditory processing uses markers of blood flow or energy-metabolism in well-defined conditions with and without auditory stimulation. Molecular markers can be used in hearing research for example to study changes in inhibitory neurotransmission systems related to hearing loss. For imaging either positron emission tomography (PET or single-photon emission computed tomography (SPECT are employed. Data analysis can encompasses voxel-wise statistical analysis of activation and calculation of quantitative parameters like receptor binding-potentials based on bio-kinetic modeling. Functional imaging has been frequently used in the context of auditory implantation. Before implantation it aims to assess intactness of the central auditory pathway and prognosis. After implantation it is used to improve understanding of the outcome with respect to auditory function and finally speech understanding, e.g. by measuring correlates of central auditory processing and neuroplasticity.

  10. Radiotracer experiments on the uptake of radionuclides by mushrooms and vegetables

    International Nuclear Information System (INIS)

    Ban-Nai, Tadaaki; Muramatsu, Yasuyuki; Yoshida, Satoshi; Yanagisawa, Kei

    1996-01-01

    Radiotracer experiments were performed to study radionuclide uptake by mushrooms and plants. Four mushroom species, Hebeloma vinosophyllum, Flammulina velutipes, Agrocybe cylindracea and Coprinus phlyctidosporus were cultivated in a flask containing medium with the radiotracers 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn. Mushrooms tended to accumulate Cs, Mn and Zn. The concentration ratio of Cs between mushroom and medium ranged from 2.6 to 21. The highest was observed in H. vinospohyllum. The concentration ratio of Mn was about 10, while the ratio of Zn ranged from 15 to 30. No noticeable accumulations were found for Sr or Co. Transfer factors (TFs) of radionuclides from soil to leaf vegetables (cabbage, Chinese cabbage, komatsuna, spinach and lettuce) were also studied using Andosol (a representative Japanese soil). The TFs of 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn for edible parts of these vegetables were (mean value) 0.11, 0.24, 0.61, 0.05 and 0.52, respectively. The TFs of Mn, Co and Zn for spinach were higher than those for the other vegetables. The distributions of Cs in different organs of the leaf vegetables were rather uniform. The TFs of Sr and Mn were higher for older (outer) leaves than younger (inner) ones. In contrast to Sr and Mn, TFs of Zn for younger leaves were higher than those for older ones

  11. Thick-film processing of Pb5Ge3O11-based ferroelectric glass-ceramics

    International Nuclear Information System (INIS)

    Cornejo, I.A.; Haun, M.J.

    1996-01-01

    Processing techniques were investigated to produce c-axis orientation, or texture, of ferroelectric Pb 5 Ge 3 O 11 -based glass-ceramic compositions during crystallization of amorphous thick-film printed samples from the Pb 5 Ge 3 O 11 -PbTiO 3 (PG-PT) and Pb 5 Ge 3 O 11 -Pb(Zr 1/2 Ti 1/2 )O 3 (PG-PZT) systems. In these systems the PG crystallized into a ferroelectric phase, producing a multiple ferroelectric phase composite at low temperatures, PG-PT or PG-PZT. In this way the non-ferroelectric component of traditional ferroelectric glass-ceramics was eliminated

  12. Oxygen transport and GeO2 stability during thermal oxidation of Ge

    Science.gov (United States)

    da Silva, S. R. M.; Rolim, G. K.; Soares, G. V.; Baumvol, I. J. R.; Krug, C.; Miotti, L.; Freire, F. L.; da Costa, M. E. H. M.; Radtke, C.

    2012-05-01

    Oxygen transport during thermal oxidation of Ge and desorption of the formed Ge oxide are investigated. Higher oxidation temperatures and lower oxygen pressures promote GeO desorption. An appreciable fraction of oxidized Ge desorbs during the growth of a GeO2 layer. The interplay between oxygen desorption and incorporation results in the exchange of O originally present in GeO2 by O from the gas phase throughout the oxide layer. This process is mediated by O vacancies generated at the GeO2/Ge interface. The formation of a substoichiometric oxide is shown to have direct relation with the GeO desorption.

  13. Radiotracer study in a bubble column reactor (visbreaker)

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Rohit Kulkarni; Pandit, A.B.; Kumar, M.M.; Berne, Ph.

    2004-01-01

    Radiotracer technique was used to measure residence time distribution (RTD) of fuel oil in a pilot-plant visbreaker with an objective to investigate hydrodynamic behaviour at different operating conditions. Bromine-82 as dibromobiphenyle was used as a tracer to measure RTD of the fuel oil. Mean residence times were determined from the measured RTD data. Tanks-in-series with backmixing model was used to simulate the measured RTD data. The results of simulation indicated that the visbreaker did not behave as a plug flow reactor as desired for visbreaking process. The presence of internals i.e. baffles inside the visbreaker decreases the mean residence time and backmixing. Thus, the designed internals have shown promising effect in terms of reduced backmixing in the visbreaker. (author)

  14. Phase diagram of the Ge-rich of the Ba–Ge system and characterisation of single-phase BaGe4

    International Nuclear Information System (INIS)

    Prokofieva, Violetta K.; Pavlova, Lydia M.

    2014-01-01

    Highlights: • The Ba-Ge phase diagram for the range 50–100 at.% Ge was constructed. • Single-phase BaGe 4 grown by the Czochralski method was characterised. • A phenomenological model for a liquid-liquid phase transition is proposed. - Abstract: The Ba–Ge binary system has been investigated by several authors, but some uncertainties remain regarding phases with Ba/Ge ⩽ 2. The goal of this work was to resolve the uncertainty about the current phase diagram of Ba–Ge by performing DTA, X-ray powder diffraction, metallographic and chemical analyses, and measurements of the electrical conductivity and viscosity. The experimental Ba–Ge phase diagram over the composition range of 50–100 at.% Ge was constructed from the cooling curves and single-phase BaGe 4 grown by the Czochralski crystal pulling method was characterised. Semiconducting BaGe 4 crystallised peritectically from the liquid phase near the eutectic. In the liquid state, the caloric effects were observed in the DTA curves at 1050 °C where there are no definite phase lines in the Ba–Ge phase diagram. These effects are confirmed by significant changes in the viscosity and electrical conductivity of a Ba–Ge alloy with eutectic composition at this temperature. A phenomenological model based on two different approaches, a phase approach and a chemical approach, is proposed to explain the isothermal liquid–liquid phase transition observed in the Ba–Ge system from the Ge side. Our results suggest that this transition is due to the peritectic reactions in the liquid phase. This reversible phase transition results in the formation of precursors of various metastable clathrate phases and is associated with sudden changes in the structure of Ba–Ge liquid alloys. Characteristics of both first- and second-order phase transitions are observed. Charge transfer appears to play an important role in this transition

  15. Uniaxially stressed Ge:Ga and Ge:Be

    Energy Technology Data Exchange (ETDEWEB)

    Dubon, Jr., Oscar Danilo [Univ. of California, Berkeley, CA (United States)

    1992-12-01

    The application of a large uniaxial stress to p-type Ge single crystals changes the character of both the valence band and the energy levels associated with the acceptors. Changes include the splitting of the fourfold degeneracy of the valence band top and the reduction of the ionization energy of shallow acceptors. In order to study the effect of uniaxial stress on transport properties of photoexcited holes, a variable temperature photo-Hall effect system was built in which stressed Ge:Ga and Ge:Be could be characterized. Results indicate that stress increases the lifetime and Hall mobility of photoexcited holes. These observations may help further the understanding of fundamental physical processes that affect the performance of stressed Ge photoconductors including the capture of holes by shallow acceptors.

  16. 124I-Epidepride: A PET radiotracer for extended imaging of dopamine D2/D3 receptors

    International Nuclear Information System (INIS)

    Pandey, Suresh; Venugopal, Archana; Kant, Ritu; Coleman, Robert; Mukherjee, Jogeshwar

    2014-01-01

    Objectives: A new radiotracer, 124 I-epidepride, has been developed for the imaging of dopamine D2/3 receptors (D2/3Rs). 124 I-Epidepride (half-life of 124 I = 4.2 days) allows imaging over extended periods compared to 18 F-fallypride (half-life of 18 F = 0.076 days) and may maximize visualization of D2/3Rs in the brain and pancreas (allowing clearance from adjacent organs). D2/3Rs are also present in pancreatic islets where they co-localize with insulin to produce granules and may serve as a surrogate marker for imaging diabetes. Methods: 124 I-Epidepride was synthesized using N-[[(2S)-1-ethylpyrrolidin-2-yl]methyl]-5-tributyltin-2, 3-dimethoxybenzamide and 124 I-iodide under no carrier added condition. Rats were used for in vitro and in vivo imaging. Brain slices were incubated with 124 I-epidepride (0.75 μCi/cc) and nonspecific binding measured with 10 μM haloperidol. Autoradiograms were analyzed by OptiQuant. 124 I-Epidepride (0.2 to 0.3 mCi, iv) was administered to rats and brain uptake at 3 hours, 24 hours, and 48 hours post injection was evaluated. Results: 124 I-Epidepride was obtained with 50% radiochemical yield and high radiochemical purity (> 95%). 124 I-Epidepride localized in the striatum with a striatum to cerebellum ratio of 10. Binding was displaced by dopamine and haloperidol. Brain slices demonstrated localization of 124 I-epidepride up until 48 hours in the striatum. However, the extent of binding was reduced significantly. Conclusions: 124 I-Epidepride is a new radiotracer suitable for extended imaging of dopamine D2/3 receptors and may have applications in imaging of receptors in the brain and monitoring pancreatic islet cell grafting

  17. Effects of flow changes on radiotracer binding: Simultaneous measurement of neuroreceptor binding and cerebral blood flow modulation.

    Science.gov (United States)

    Sander, Christin Y; Mandeville, Joseph B; Wey, Hsiao-Ying; Catana, Ciprian; Hooker, Jacob M; Rosen, Bruce R

    2017-01-01

    The potential effects of changes in blood flow on the delivery and washout of radiotracers has been an ongoing question in PET bolus injection studies. This study provides practical insight into this topic by experimentally measuring cerebral blood flow (CBF) and neuroreceptor binding using simultaneous PET/MRI. Hypercapnic challenges (7% CO 2 ) were administered to non-human primates in order to induce controlled increases in CBF, measured with pseudo-continuous arterial spin labeling. Simultaneously, dopamine D 2 /D 3 receptor binding of [ 11 C]raclopride or [ 18 F]fallypride was monitored with dynamic PET. Experiments showed that neither time activity curves nor quantification of binding through binding potentials ( BP ND ) were measurably affected by CBF increases, which were larger than two-fold. Simulations of experimental procedures showed that even large changes in CBF should have little effect on the time activity curves of radiotracers, given a set of realistic assumptions. The proposed method can be applied to experimentally assess the flow sensitivity of other radiotracers. Results demonstrate that CBF changes, which often occur due to behavioral tasks or pharmacological challenges, do not affect PET [ 11 C]raclopride or [ 18 F]fallypride binding studies and their quantification. The results from this study suggest flow effects may have limited impact on many PET neuroreceptor tracers with similar properties.

  18. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique

    International Nuclear Information System (INIS)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J.; Biswal, Jayashree; Sharma, Vijay K.; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K.; Rao, S. Madhukar; Dash, A.

    2016-01-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. - Highlights: • Radiotracer experiments were conducted to measure RTD of liquid phase in a pulp digester • Mean residence times of white liquor were measured • Axial dispersion and tanks-in-series models were used to investigate flow patterns • Parallel flow paths were observed in first section of the digester • Optimized flow rates of biomass and liquor were obtained

  19. Four-jet final state production in $e^+ e^-$ collisions at centre-of-mass energies ranging from 130 to 184 GeV

    CERN Document Server

    Barate, R; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Nief, J Y; Pietrzyk, B; Boix, G; Casado, M P; Chmeissani, M; Crespo, J M; Delfino, M C; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Morawitz, P; Park, I C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Iaselli, Giuseppe; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Alemany, R; Becker, U; Bright-Thomas, P G; Casper, David William; Cattaneo, M; Cerutti, F; Ciulli, V; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Gianotti, F; Hagelberg, R; Hansen, J B; Harvey, J; Janot, P; Jost, B; Lehraus, Ivan; Mato, P; Minten, Adolf G; Moneta, L; Pacheco, A; Pusztaszeri, J F; Ranjard, F; Rolandi, Luigi; Rousseau, D; Schlatter, W D; Schmitt, M; Schneider, O; Tejessy, W; Teubert, F; Tomalin, I R; Vreeswijk, M; Wachsmuth, H W; Wagner, A; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rosnet, P; Fearnley, Tom; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Vayaki, Anna; Blondel, A; Brient, J C; Machefert, F P; Rougé, A; Rumpf, M; Valassi, Andrea; Videau, H L; Boccali, T; Focardi, E; Parrini, G; Zachariadou, K; Cavanaugh, R J; Corden, M; Georgiopoulos, C H; Hühn, T; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Lynch, J G; Negus, P; O'Shea, V; Raine, C; Scarr, J M; Smith, K; Teixeira-Dias, P; Thompson, A S; Thomson, E; Thomson, F; Ward, J; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Marinelli, N; Moutoussi, A; Nash, J; Sedgbeer, J K; Spagnolo, P; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Buck, P G; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Whelan, E P; Williams, M I; Giehl, I; Hoffmann, C; Jakobs, K; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Bujosa, G; Carr, J; Coyle, P; Ealet, A; Fouchez, D; Leroy, O; Motsch, F; Payre, P; Talby, M; Sadouki, A; Thulasidas, M; Tilquin, A; Trabelsi, K; Aleppo, M; Antonelli, M; Ragusa, F; Berlich, R; Blum, Walter; Büscher, V; Dietl, H; Ganis, G; Gotzhein, C; Kroha, H; Lütjens, G; Lutz, Gerhard; Mannert, C; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Stenzel, H; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Chen, S; Davier, M; Duflot, L; Grivaz, J F; Höcker, A; Jacholkowska, A; Kado, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Schune, M H; Serin, L; Tournefier, E; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Bettarini, S; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sciabà, A; Sguazzoni, G; Steinberger, Jack; Tenchini, Roberto; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Bryant, L M; Chambers, J T; Coles, J; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Maley, P; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Fabbro, B; Faïf, G; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Przysiezniak, H; Rander, J; Renardy, J F; Rosowsky, A; Roussarie, A; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Brew, C A J; Cartwright, S L; Combley, F; Kelly, M S; Lehto, M H; Reeve, J; Thompson, L F; Affholderbach, K; Böhrer, A; Brandt, S; Cowan, G D; Foss, J; Grupen, Claus; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pütz, J; Rothberg, J E; Wasserbaech, S R; Williams, R W; Armstrong, S R; Charles, E; Elmer, P; Ferguson, D P S; Gao, Y; González, S; Greening, T C; Hayes, O J; Hu, H; Jin, S; McNamara, P A; Nachtman, J M; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Walsh, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    1998-01-01

    The four jet topology is analysed in the ALEPH data taken between November 1995 and November 1997, at centre-of-mass energies ranging from 130 to 184 GeV. While an unexpected accumulation of events with a dijet mas sum around 105 GeV/c**2 had been observed during the first run in 1995 at 130/136 GeV, corresponding to an integrated luminosity of 5.7 pb-1, no significant differences between data and standard model prediction is noticed, either in the high energy runs (81.1 pb-1 taken at centre-of-mass energies from 161 to 184 GeV) or in the 7.1 pb-1 recorded during a new short run at 130/136 GeV in 1997. We have found no other explanation for the earlier reported ``four jet anomaly'' than a statistical fluctuation.

  20. Four-jet final state production in e+e- collisions at centre-of-mass energies ranging from 130 to 184 GeV

    Science.gov (United States)

    ALEPH Collaboration; Barate, R.; Buskulic, D.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Nief, J.-Y.; Pietrzyk, B.; Boix, G.; Casado, M. P.; Chmeissani, M.; Crespo, J. M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Graugès, E.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, Ll. M.; Morawitz, P.; Park, I. C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Becker, U.; Bright-Thomas, P.; Casper, D.; Cattaneo, M.; Cerutti, F.; Ciulli, V.; Dissertori, G.; Drevermann, H.; Forty, R. W.; Frank, M.; Gianotti, F.; Hagelberg, R.; Hansen, J. B.; Harvey, J.; Janot, P.; Jost, B.; Lehraus, I.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.-F.; Ranjard, F.; Rolandi, L.; Rousseau, D.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Teubert, F.; Tomalin, I. R.; Vreeswijk, M.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Badaud, F.; Chazelle, G.; Deschamps, O.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Fearnley, T.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Rensch, B.; Wäänänen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J.-C.; Machefert, F.; Rougé, A.; Rumpf, M.; Valassi, A.; Videau, H.; Boccali, T.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Huehn, T.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Lynch, J. G.; Negus, P.; O'Shea, V.; Raine, C.; Scarr, J. M.; Smith, K.; Teixeira-Dias, P.; Thompson, A. S.; Thomson, E.; Thomson, F.; Buchmüller, O.; Dhamotharan, S.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Girone, M.; Goodsir, S.; Martin, E. B.; Marinelli, N.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Spagnolo, P.; Williams, M. D.; Ghete, V. M.; Girtler, P.; Kneringer, E.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Buck, P. G.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Jones, R. W. L.; Whelan, E. P.; Williams, M. I.; Giehl, I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Carr, J.; Coyle, P.; Ealet, A.; Fouchez, D.; Leroy, O.; Motsch, F.; Payre, P.; Talby, M.; Sadouki, A.; Thulasidas, M.; Tilquin, A.; Trabelsi, K.; Aleppo, M.; Antonelli, M.; Ragusa, F.; Berlich, R.; Blum, W.; Büscher, V.; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lütjens, G.; Lutz, G.; Mannert, C.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Höcker, A.; Jacholkowska, A.; Kado, M. M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Schune, M.-H.; Serin, L.; Tournefier, E.; Veillet, J.-J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; dell'Orso, R.; Fantechi, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Sciabà, A.; Sguazzoni, G.; Steinberger, J.; Tenchini, R.; Vannini, C.; Venturi, A.; Verdini, P. G.; Blair, G. A.; Bryant, L. M.; Chambers, J. T.; Coles, J.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Maley, P.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Fabbro, B.; Faïf, G.; Lançon, E.; Lemaire, M.-C.; Locci, E.; Perez, P.; Przysiezniak, H.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Kim, H. Y.; Konstantinidis, N.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Kelly, M. S.; Lehto, M.; Reeve, J.; Thompson, L. F.; Affholderbach, K.; Böhrer, A.; Brandt, S.; Cowan, G.; Foss, J.; Grupen, C.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R. W.; Armstrong, S. R.; Charles, E.; Elmer, P.; Ferguson, D. P. S.; Gao, Y.; González, S.; Greening, T. C.; Hayes, O. J.; Hu, H.; Jin, S.; McNamara, P. A., III; Nachtman, J. M.; Nielsen, J.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Scott, I. J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Yamartino, J. M.; Zobernig, G.

    1998-02-01

    The four jet topology is analysed in the ALEPH data taken between November 1995 and October 1997, at centre-of-mass energies ranging from 130 to 184 GeV. While an unexpected accumulation of events with a dijet mass sum around 105 GeV/c2 had been observed during the first run in 1995 at 130/136 GeV, corresponding to an integrated luminosity of 5.7 pb-1, no significant differences between data and standard model prediction is seen, either in the high energy runs (81.1 pb-1 taken at centre-of-mass energies from 161 to 184 GeV) or in the 7.1 pb-1 recorded during a new short run at 130/136 GeV in 1997. We have found no other explanation for the earlier reported ``four jet anomaly'' than a statistical fluctuation.

  1. Thermoelectric properties of c-GeSb{sub 0.75}Te{sub 0.5} to h-GeSbTe{sub 0.5} thin films through annealing treatment effects

    Energy Technology Data Exchange (ETDEWEB)

    Vora-ud, Athorn, E-mail: athornvora-ud@snru.ac.th [Program of Physics, Faculty of Science and Technology, Sakon Nakhon Rajabhat University, Mueang District, Sakon Nakhon 47000 (Thailand); Thermoelectrics Research Center, Research and Development Institution, Sakon Nakhon Rajabhat University, Mueang District, Sakon Nakhon 47000 (Thailand); Horprathum, Mati, E-mail: mati.horprathum@nectec.or.th [National Electronics and Computer Technology Center, National Science and Technology Development Agency, Pathumthani 12120 (Thailand); Eiamchai, Pitak [National Electronics and Computer Technology Center, National Science and Technology Development Agency, Pathumthani 12120 (Thailand); Muthitamongkol, Pennapa; Chayasombat, Bralee; Thanachayanont, Chanchana [National Metal and Materials Technology Center, National Science and Technology Development Agency, Pathumthani 12120 (Thailand); Pankiew, Apirak [National Electronics and Computer Technology Center, National Science and Technology Development Agency, Pathumthani 12120 (Thailand); Klamchuen, Annop [National Nanotechnology Center, National Science and Technology Development Agency, Pathumthani 12120 (Thailand); Naenkieng, Daengdech; Plirdpring, Theerayuth; Harnwunggmoung, Adul [Thermoelectric and Nanotechnology Research Center, Faculty of Science and Technology, Rajamangala University of Technology Suvarnabhumi, Huntra Phranakhon, Si Ayutthaya 13000 (Thailand); Charoenphakdee, Anek [NANO-Thermoelectrics Research Center, Division of Applied Physics, Faculty of Sciences and Liberal Arts, Rajamangala University of Technology Isan, Mueng Nakorn Ratchasima 30000 Thailand (Thailand); Somkhunthot, Weerasak [Program of Physics, Faculty of Science and Technology, Loei Rajabhat University, Muang District, Loei 42000 (Thailand); and others

    2015-11-15

    Germanium–Antimony–Tellurium (Ge–Sb–Te) thin films were deposited on silicon wafers with 1-μm silicon dioxide (SiO{sub 2}/Si) by pulsed dc magnetron sputtering from a 99.99% GeSbTe target of 1:1:1 ratio at ambient temperature. The samples were annealed at 573, 623, 673, and 723 K for 3600 s in a vacuum state. The effects of the annealing treatment on phase identification, atomic composition, morphology and film thickness, carrier concentration, mobility, and Seebeck coefficient of the Ge–Sb–Te samples have been investigated by grazing-incidence X-ray diffraction, auger electron spectroscopy, field-emission scanning electron microscopy, Hall-effect measurements, and steady state method, respectively. The results demonstrated that the as-deposited Ge–Sb–Te sample was amorphous. Atomic composition of as-deposited and annealed films at 573 K and 623 K were GeSb{sub 0.75}Te{sub 0.5} while annealed films at 673 K and 723 K were GeSbTe{sub 0.5} due to Sb-rich GeSb{sub 0.75}Te{sub 0.5}. The samples annealed at 573 K and 623 K showed the crystal phases of cubic structure (c-GeSb{sub 0.75}Te{sub 0.5}) into hexagonal structure (h-GeSbTe{sub 0.5}) after annealing at 673 K and 723 K. The study demonstrated the insulating condition from the as-deposited GeSbTe film, and the changes towards the thermoelectric properties from the annealing treatments. The GeSbTe films annealed at 673 K yielded excellent thermoelectric properties with the electrical resistivity, Seebeck coefficient, and power factor at approximately 1.45 × 10{sup −5} Ωm, 71.07 μV K{sup −1}, and 3.48 × 10{sup −4} W m{sup −1} K{sup −2}, respectively. - Highlights: • GeSbTe thin films were successfully sputtered for thermoelectric properties. • GeSbTe films were examined among physical, electrical and thermoelectric properties. • Thermoelectric properties were discussed based on composition of the films.

  2. Adaptation of enterovirus 71 to adult interferon deficient mice.

    Directory of Open Access Journals (Sweden)

    Elizabeth A Caine

    Full Text Available Non-polio enteroviruses, including enterovirus 71 (EV71, have caused severe and fatal cases of hand, foot and mouth disease (HFMD in the Asia-Pacific region. The development of a vaccine or antiviral against these pathogens has been hampered by the lack of a reliable small animal model. In this study, a mouse adapted EV71 strain was produced by conducting serial passages through A129 (α/β interferon (IFN receptor deficient and AG129 (α/β, γ IFN receptor deficient mice. A B2 sub genotype of EV71 was inoculated intraperitoneally (i.p. into neonatal AG129 mice and brain-harvested virus was subsequently passaged through 12 and 15 day-old A129 mice. When tested in 10 week-old AG129 mice, this adapted strain produced 100% lethality with clinical signs including limb paralysis, eye irritation, loss of balance, and death. This virus caused only 17% mortality in same age A129 mice, confirming that in the absence of a functional IFN response, adult AG129 mice are susceptible to infection by adapted EV71 isolates. Subsequent studies in adult AG129 and young A129 mice with the adapted EV71 virus examined the efficacy of an inactivated EV71 candidate vaccine and determined the role of humoral immunity in protection. Passive transfer of rabbit immune sera raised against the EV71 vaccine provided protection in a dose dependent manner in 15 day-old A129 mice. Intramuscular injections (i.m. in five week-old AG129 mice with the alum adjuvanted vaccine also provided protection against the mouse adapted homologous strain. No clinical signs of disease or mortality were observed in vaccinated animals, which received a prime-and-boost, whereas 71% of control animals were euthanized after exhibiting systemic clinical signs (P<0.05. The development of this animal model will facilitate studies on EV71 pathogenesis, antiviral testing, the evaluation of immunogenicity and efficacy of vaccine candidates, and has the potential to establish correlates of protection

  3. Production status of GaAs/Ge solar cells and panels

    Science.gov (United States)

    Smith, B.; Gillanders, M.; Vijayakumar, P.; Lillington, D.; Yang, H.; Rolph, R.

    1991-01-01

    GaAs/Ge solar cells with lot average efficiencies in excess of 18 percent were produced by MOCVD growth techniques. A description of the cell, its performance and the production facility are discussed. Production GaAs/Ge cells of this type were recently assembled into circuits and bonded to aluminum honeycomb panels to be used as the solar array for the British UOSAT-F program.

  4. P-barp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    International Nuclear Information System (INIS)

    Islam, M.M.; Fearnley, T.; Guillaud, J.P.

    1984-01-01

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range √s approx. (10-1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in p-barp and pp differential cross-sections. As energy increases beyond the ISR range (√s = (23-62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between p-barp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of p-barp and pp differential cross-sections at future collider energies √s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the p-barp differential cross-section at the ISR and SPS collider in the abs (t)-range (0.5-2.0) (GeV) 2 is stressed

  5. anti pp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.M. (Connecticut Univ., Storrs (USA). Dept. of Physics); Fearnley, T. (University Coll., London (UK). Dept. of Physics and Astronomy); Guillaud, J.P. (Grenoble-1 Univ., 74 - Annecy (France). Lab. de Physique des Particules)

    1984-06-21

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range ..sqrt..anti s approx.= (10/1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in anti pp and pp differential cross-sections. As energy increases beyond the ISR range (..sqrt..anti s = (23/62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between anti pp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of anti pp and pp differential cross-sections at future collider energies ..sqrt..s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the anti pp differential cross-section at the ISR and SPS collider in the vertical stroketvertical stroke-range (0.5/2.0) (GeV)/sup 2/ is stressed.

  6. P-barp and pp elastic scattering from 10 GeV to 1000 GeV centre-of-mass energy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.M. (Connecticut Univ., Storrs (USA). Dept. of Physics); Fearnley, T. (University Coll., London (UK). Dept. of Physics and Astronomy); Guillaud, J.P. (L.A.P.P. - BP909, 74019 Annecy-Le-Vieux Cedex, France)

    1984-06-21

    Antiproton-proton and proton-proton elastic scattering are studied simultaneously over the energy range ..sqrt..s approx. (10-1000) GeV in a nucleon valence core model proposed earlier. The scattering is described as primarily due to two processes: diffraction and hard scattering. The latter originates from the scattering of a nucleon core off another core. Destructive interference between the two processes produces dips in p-barp and pp differential cross-sections. As energy increases beyond the ISR range (..sqrt..s = (23-62) GeV), the dips get filled up, and eventually transform into shoulders or breaks at collider energies. Differences between p-barp and pp differential cross-sections persist even at collider energies. Comparison with ISR data shows that the model provides a quantitative description of pp elastic scattering in this energy range. Predictions of p-barp and pp differential cross-sections at future collider energies ..sqrt..s = 800 and 2000 GeV are given. In order to distinguish between competing models, need for measuring the p-barp differential cross-section at the ISR and SPS collider in the abs (t)-range (0.5-2.0) (GeV)/sup 2/ is stressed.

  7. Evaluation of radiotracers for the detection of atherosclerotic vulnerable plaque and myocardial angiogenesis

    International Nuclear Information System (INIS)

    Dimastromatteo, Julien

    2010-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide. Coronary events are mainly caused by coronary plaque rupture or erosion. However, at present, there is no noninvasive tool available for the detection of vulnerable plaques. The first part of thesis is about evaluation of new radiotracers for the detection of atherosclerotic vulnerable plaques. 99m Tc-B2702p, 20 derivatives, 99m Tc-VP and 99m Tc-VINP28 were evaluated in an experimental model of atherosclerosis (ApoE-/- mice with left carotid artery ligation). 99m Tc- B2702p1 is a potentially useful radiotracer for the in vivo molecular imaging of VCAM-1 expression in atherosclerotic plaques. Myocardial angiogenesis is an important post infarction phenomenon. Angiogenic therapy improves experimentally cardiac parameters. However, clinical trials using the same therapy are more controversial. At present, clinical imaging tools don't allow us to assess angiogenesis therapy. The second part of thesis is about validation of 99m Tc-RAFT-RGD in the detection of myocardial angiogenesis. 99m Tc-RAFT-RGD allow us to perform noninvasive molecular imaging of myocardial angiogenesis in an experimental model. (author)

  8. Characterization of a radiotracer-based 3-hydroxy-1-methyl peridine by its analogue Rhene

    International Nuclear Information System (INIS)

    Zitouni, Zeineb

    2010-01-01

    Since the discovery of artificial radioactivity in 1934, nuclear doctors have a variety of radioactive isotopes as indicators and markers. With these radioactive isotopes, it is possible to trace an atom or a chemical species without disrupting the physical behavior, chemical or biological. The branch of medicine and medical specialty now devoted to the use of radioactive elements for examination or treatment of patients, particularly the brain. Having a close relationship with radiobiology, radiation protection and Radiopharmacy, Nuclear Medicine Specialist is empowered to handle potentially dangerous isotope, observing precautions and regulations designed to reduce their risks. These radionuclides are used for exploration of cell kinetics, pharmacokinetics or for scans. Activities under this project led to the synthesis of N-methylferrocene, its characterization and its labeling with technetium 99 m. For the characterization of the radiotracer synthesized, we used to study the properties of complex similar models, labeled with rhenium. To verify and confirm this work, we propose the following perspectives: - Confirm the structure of N-methyl rhenium by nuclear magnetic resonance and single crystal X ray crystallography. - Develop and characterize new radiotracers brain.

  9. Ge-Au eutectic bonding of Ge (100) single crystals

    International Nuclear Information System (INIS)

    Knowlton, W.B.; Beeman, J.W.; Emes, J.H.; Loretto, D.; Itoh, K.M.; Haller, E.E.

    1993-01-01

    The author present preliminary results on the eutectic bonding between two (100) Ge single crystal surfaces using thin films of Au ranging from 900 angstrom/surface to 300 angstrom/surface and Pd (10% the thickness of Au). Following bonding, plan view optical microscopy (OM) of the cleaved interface of samples with Au thicknesses ≤ 500 angstrom/surface show a eutectic morphology more conducive to phonon transmission through the bond interface. High resolution transmission electron microscopy (HRTEM) cross sectional interface studies of a 300 angstrom/surface Au sample show epitaxial growth of Ge. In sections of the bond, lattice continuity of the Ge is apparent through the interface. TEM studies also reveal heteroepitaxial growth of Au with a Au-Ge lattice mismatch of less than 2%. Eutectic bonds with 200 angstrom/surface Au have been attained with characterization pending. An optical polishing technique for Ge has been optimized to insure intimate contact between the Ge surfaces prior to bonding. Interferometry analysis of the optically polished Ge surface shows that surface height fluctuations lie within ±150 angstrom across an interval of lmm. Characterization of phonon transmission through the interface is discussed with respect to low temperature detection of ballistic phonons

  10. Energy levels of germanium, Ge I through Ge XXXII

    International Nuclear Information System (INIS)

    Sugar, J.; Musgrove, A.

    1993-01-01

    Atomic energy levels of germanium have been compiled for all stages of ionization for which experimental data are available. No data have yet been published for Ge VIII through Ge XIII and Ge XXXII. Very accurate calculated values are compiled for Ge XXXI and XXXII. Experimental g-factors and leading percentages from calculated eigenvectors of levels are given. A value for the ionization energy, either experimental when available or theoretical, is included for the neutral atom and each ion. section

  11. Oxidation of hydrogen terminated Ge(1 0 0) surface in the presence of iodine in methanol

    International Nuclear Information System (INIS)

    Lee, Younghwan; Park, Kibyung; Lim, Sangwoo

    2008-01-01

    Surface reaction on Ge(1 0 0) in liquid methanol (MeOH) was systematically studied. In particular, the characteristics of the Ge surface in the presence of iodine (I 2 ) in MeOH were investigated. MeOH treatment of the Ge surface in the presence of 0.05 or 0.005 mM of I 2 exhibited a similar result to that without I 2 , which produces a GeO x -dominant oxide structure. However, when the concentration of I 2 in MeOH increased to 0.5 mM, Ge surface revealed a GeO 2 -dominant oxide structure. Therefore, it is believed that the addition of enough I 2 in MeOH modifies the Ge oxidation mechanism. Hydroxide produced by the reaction between MeOH and the iodine radical may oxidize the Ge surface to form a Ge-O layer. Because MeOH is greatly consumed by chain and series reactions when I 2 concentration is high, a GeO 2 structure is not etched and a GeO 2 -dominant oxide structure is obtained with the addition of 0.5 mM I 2 in MeOH. The modified oxide layer prepared in MeOH with 0.5 mM I 2 exhibited an atomically smoother surface compared to a pure MeOH- or H 2 O 2 -treated Ge surface and a much thinner oxide layer than H 2 O 2 treatment.

  12. Gamma-ray Spectroscopy of Nano-second Isomers in Neutron-rich Ni Region Produced by Deep-inelastic Collisions

    Science.gov (United States)

    Ishii, Tetsuro; Asai, Masato; Kleinheinz, Peter; Matsuda, Makoto; Ichikawa, Shinichi; Makishima, Akiyasu; Ogawa, Masao

    2001-10-01

    We have been studying nuclear structure of neutron-rich nuclei produced by heavy-ion deep-inelastic collisions at the JAERI Tandem Booster facility. In our method using an `isomer-scope', γ-rays only from isomers with T_1/2 > 1ns are measured by shielding Ge detectors from prompt γ rays emitted at the target position. Atomic numbers of isomers can be also identified by detecting projectile-like fragments with Si Δ E-E detectors. Until now, we have found several new isomers in neutron-rich Ni region using about 8 MeV/nucleon ^70Zn, ^76Ge and ^82Se beams and a ^198Pt target of 4.3 mg/cm^2 thickness. In the doubly magic ^68_28Ni_40, the (ν g_9/2^2 ν p_1/2-2)8^+ isomer with T_1/2=23(1) ns was found. In its neighbor nuclei ^69,71Cu, the 19/2^- isomers were found and the energy levels decaying from the isomers can be calculated very accurately by a parameter-free shell model calculation using experimental energy levels as two-body residual interactions. I will also briefly discuss nano-second isomers in ^32,33Si and ^34P produced by 9 MeV/nucleon ^37Cl beams.

  13. Disruption of Bombyx mori nucleopolyhedrovirus ORF71 (Bm71) results in inefficient budded virus production and decreased virulence in host larvae.

    Science.gov (United States)

    Zhang, Min-Juan; Cheng, Ruo-Lin; Lou, Yi-Han; Ye, Wan-Lu; Zhang, Tao; Fan, Xiao-Ying; Fan, Hai-Wei; Zhang, Chuan-Xi

    2012-08-01

    The Bombyx mori nucleopolyhedrovirus (BmNPV) is a baculovirus that selectively infects domestic silkworm. BmNPV ORF71 (Bm71) is not a core set gene in baculovirus and shares 92 % amino acid sequence identity with Autographa californica multinucleocapsid NPV ORF88 (Ac88/cg30). Previously, it has been reported that virus lacking Ac88 had no striking phenotypes in cell lines or host larvae. However, the exact role of Bm71 during BmNPV life cycle remains unknown. In the present study, we constructed a Bm71-disrupted (Bm71-D) virus and assessed the effect of the Bm71 disruption on viral replication and viral phenotype throughout the viral life cycle. Results showed that the Bm71-D bacmid could successfully transfect Bm5 cell lines and produce infectious budded virus (BV). But the BV titer was 10- to 100-fold lower than that of the wild-type (WT) virus during infection, and the decreased BV titer was rescued by Bm71 gene repair virus (Bm71-R). A larval bioassay showed that Bm71-D virus took 7.5 h longer than the WT to kill Bombyx mori larvae. Transmission electron microscopy analysis indicated that the Bm71-D virus-infected cells had typical virogenic stroma, bundles of nucleocapsids and polyhedra. Taken together, these results suggest that Bm71 has important implications for determining BV yield and virulence in viral life cycle even though it is not an essential gene for replication of BmNPV.

  14. A SEARCH FOR PULSATIONS FROM GEMINGA ABOVE 100 GeV WITH VERITAS

    Energy Technology Data Exchange (ETDEWEB)

    Aliu, E. [Department of Physics and Astronomy, Barnard College, Columbia University, NY 10027 (United States); Archambault, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Archer, A.; Beilicke, M.; Buckley, J. H.; Bugaev, V. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Aune, T. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Barnacka, A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Benbow, W.; Cerruti, M. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Bird, R. [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland); Byrum, K. [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Cardenzana, J. V.; Dickinson, H. J.; Eisch, J. D. [Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Chen, X. [Institute of Physics and Astronomy, University of Potsdam, D-14476 Potsdam-Golm (Germany); Ciupik, L. [Astronomy Department, Adler Planetarium and Astronomy Museum, Chicago, IL 60605 (United States); Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Cui, W. [Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907 (United States); Dumm, J., E-mail: mccann@kicp.uchicago.edu, E-mail: gtrichards@gatech.edu [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); and others

    2015-02-10

    We present the results of 71.6 hr of observations of the Geminga pulsar (PSR J0633+1746) with the VERITAS very-high-energy gamma-ray telescope array. Data taken with VERITAS between 2007 November and 2013 February were phase-folded using a Geminga pulsar timing solution derived from data recorded by the XMM- Newton and Fermi-LAT space telescopes. No significant pulsed emission above 100 GeV is observed, and we report upper limits at the 95% confidence level on the integral flux above 135 GeV (spectral analysis threshold) of 4.0 × 10{sup –13} s{sup –1} cm{sup –2} and 1.7 × 10{sup –13} s{sup –1} cm{sup –2} for the two principal peaks in the emission profile. These upper limits, placed in context with phase-resolved spectral energy distributions determined from 5 yr of data from the Fermi-Large Area Telescope (LAT), constrain possible hardening of the Geminga pulsar emission spectra above ∼50 GeV.

  15. Magnetic properties of ultrathin Co/Ge(111) and Co/Ge(100) films

    International Nuclear Information System (INIS)

    Cheng, W. C.; Tsay, J. S.; Yao, Y. D.; Lin, K. C.; Yang, C. S.; Lee, S. F.; Tseng, T. K.; Neih, H. Y.

    2001-01-01

    The orientation of the magnetization and the occurrence of interfacial ferromagnetic inactive layers for ultrathin Co films grown on Ge(111) and Ge(100) surfaces have been studied using the in situ surface magneto-optic Kerr effect. On a Ge(111) substrate, cobalt films (≤28 monolayers) with in-plane easy axis of magnetization have been observed; however, on a Ge(100) substrate, ultrathin Co films (14 - 16 monolayers) with canted out-of-plane easy axis of magnetization were measured. The ferromagnetic inactive layers were formed due to the intermixing of Co and Ge and lowering the Curie temperature by reducing Co film thickness. The Co - Ge compound inactive layers were 3.8 monolayers thick for Co films grown on Ge(111) and 6.2 monolayers thick for Co films deposited on Ge(100). This is attributed to the difference of the density of surface atoms on Ge(111) and Ge(100). [copyright] 2001 American Institute of Physics

  16. Microscopic parameters of heterostructures containing nanoclusters and thin layers of Ge in Si matrix

    CERN Document Server

    Erenburg, S B; Stepina, N P; Nikiforov, A I; Nenashev, A V; Mazalov, L N

    2001-01-01

    GeK XAFS measurements have been performed using the total electron yield detection mode for pseudomorphous Ge films deposited on Si(0 0 1) substrate via molecular beam epitaxy at 300 deg. C. The samples have been produced by thrice repeating the growing procedure separated by deposition of blocking Si layers at 500 deg. C. The local microstructure parameters (interatomic distances, Ge coordination numbers) are linked to nanostructure morphology and adequate models are suggested and discussed. It was established that pseudomorphous 4-monolayer Ge films contain 50% of Si atoms on the average. Pyramid-like, pure Ge islands formed in the Stranski-Krastanov growth are characterized by the interatomic Ge-Ge distances of 2.41 A (by 0.04 A less than in bulk Ge) and the Ge-Si distances of 2.37 A. It was revealed that the pure Ge nanoclusters are covered by a 1-2-monolayer film with admixture on the average of a 50% Si atom impurity from blocking Si layers.

  17. Proportional counter response calculations for gallium solar neutrino detectors

    International Nuclear Information System (INIS)

    Kouzes, R.T.; Reynolds, D.

    1989-01-01

    Gallium bases solar neutrino detectors are sensitive to the primary pp reaction in the sun. Two experiments using gallium, SAGE in the Soviet Union and GALLEX in Europe, are under construction and will produce data by 1989. The radioactive /sup 71/Ge produced by neutrinos interacting with the gallium detector material, is chemically extracted and counted in miniature proportional counters. A number of calculations have been carried out to simulate the response of these counters to the decay of /sup 71/Ge and to background events

  18. Determination of retention period of sewage in a filtration plant using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1979-01-01

    A radiotracer investigation was carried out at Dadar sewage purification plant, Bombay, for measuring the retention period of a trickling filter unit. The method is based on the addition of 82 Br tracer in the form of NH 4 Br solution at the inlet and continuous recording of the tracer at the flow stream. Results obtained in the actual investigation are also given. (auth.)

  19. A radiotracer technique for testing a high pressure gas compressor for oil leakage

    International Nuclear Information System (INIS)

    Eapen, A.C.; Kirti; Jain, S.K.; Gupta, P.P.

    1979-01-01

    The radiotracer investigations carried out at NOCIL, Bombay, to measure the amount of lubrication oil present in the gas being compressed in a 1000 H.P. centrifugal compressor are described. By injecting a few mCi 131 I labelled glyceryl trioleate tracer and monitoring the radioactivity of the outlet gas for about 20 hours, the extent of the oil present in the gas could be determined. (auth.)

  20. Radiotracer laboratory for agricultural research at the Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Nashriyah Mat; Misman Sumin; Maizatul Akmam Mhd Nasir

    2007-01-01

    Radiotracer Laboratory for agricultural research at the Malaysian Nuclear Agency was established since 1990. It accommodates three laboratories, three chemical temporary storage compartments plus one compartment for storage of pressurized gas. This facility is situated in ground floor of Block 44, Agrotechnology and Biosciences Division, Dengkil Complex. Currently it houses a liquid scintillation counter, sample oxidizer, gas liquid chromatography, high performance liquid chromatography and auxiliary equipments. A road map for this laboratory will be discussed in relation with present scenario i.e. R and D service, training and consultancy provided by this laboratory; and future requirements and direction. (Author)

  1. Neutron-capture cross-section measurements of 74Ge and 76Ge in the energy region 0.4-14.8 MeV for neutrinoless double β decay applications

    Science.gov (United States)

    Bhike, Megha; Tornow, Werner

    2013-10-01

    Fast neutron capture cross sections for the reactions 74Ge(n, γ)75Ge and 76Ge(n, γ)77Ge have been measured in the neutron energy region 0.4-14.8 MeV with the activation method. The results are important to identify backgrounds in the neutrinoless double- β decay experiments GERDA and MAJORANA, which use germanium as both source and detector. Isotopically enriched targets which consisted of 86% of 76Ge and 14% of 74Ge were irradiated with mono-energetic neutrons produced via 3H(p,n)3He, 2H(d,n)3He and 3H(d,n)4He reactions. The cross sections were determined relative to 197Au(n, γ)198Au, 115In(n,n')115mIn and 197Au(n,2n)196Au standard cross sections. The activities of the products were measured using high-resolution γ-ray spctroscopy. The present results are compared with the evaluated data from ENDF/B-VII.1 and TALYS.

  2. Radiotracer investigation of the cold-vapour atomic absorption method of analysis for trace mercury

    International Nuclear Information System (INIS)

    Stuart, D.C.

    1978-01-01

    Because of certain problems found in application of the atomic absorption method for trace analysis of mercury, a careful check of the procedures used was undertaken, with radiotracer mercury to facilitate the investigation. The results obtained, in conjunction with those of sample ashing procedures, indicate that the method is less straightforward than its simplicity suggests. (Auth.)

  3. Development of [11C]-α-aminoisobutyric acid and [18F]-haloperidol as substrate-specific radiotracers

    International Nuclear Information System (INIS)

    Zanzonico, P.B.

    1982-01-01

    In light of the emergence of positron emission tomography (PET), two new substrate-specific radiotracers have been synthesized and evaluated as potential agents for the study of specific physiological processes: [1- 11 C]-α-aminoisobutyric acid ([1- 11 C]-AIB), a transport system-specific radiotracer for tumor localization and for the assessment of amino acid transport in vivo; and [ 18 F]-haloperidoll, a receptor-binding radiotracer for the assessment of brain dopamine receptors in vivo. AIB, a non-metabolized amino acid, accumulates in cells, particularly malignant cells, via the A type, or ''alanine-preferring'', amino acid transport system [1- 11 C]-AIB in normal and in treated and untreated tumor-bearing rats, in tumor-bearing dogs, and in a tumor-bearing patient indicate rapid blood clearance and, concomitantly, rapid tissue localization, with slow net redistribution. Generally, there was selective localization in the kidney, in the liver, and in the pancreas, as well as in various tumors. The canine tumors and the human tumor were well visualized by external scintigraphy, especially when utilizing PET. [ 18 F]-Haloperidol, a dopamine receptor-binding neuroleptic of the butyrophenone series widely used in the management of schizophrenia was prepared via the Balz-Schiemann reaction. As the haloperdol dose administered to mice was increased from 0.01 to 1000 μg/kg, the relative concentration (μCi found per gm tisue sample/μCi injected per gm body mass) of [ 18 F]-haloperidol at 1 hr decreased from 30 to 1.0 in the striatum and from 8.0 to 1.0 in the cerebellum. The decrease in striatum radioactivity reflects competition between labeled and unlabeled haloperidol for dopamine receptors

  4. Simultaneous ultra-long data retention and low power based on Ge10Sb90/SiO2 multilayer thin films

    Science.gov (United States)

    You, Haipeng; Hu, Yifeng; Zhu, Xiaoqin; Zou, Hua; Song, Sannian; Song, Zhitang

    2018-02-01

    In this article, Ge10Sb90/SiO2 multilayer thin films were prepared to improve thermal stability and data retention for phase change memory. Compared with Ge10Sb90 monolayer thin film, Ge10Sb90 (1 nm)/SiO2 (9 nm) multilayer thin film had higher crystallization temperature and resistance contrast between amorphous and crystalline states. Annealed Ge10Sb90 (1 nm)/SiO2 (9 nm) had uniform grain with the size of 15.71 nm. After annealing, the root-mean-square surface roughness for Ge10Sb90 (1 nm)/SiO2 (9 nm) thin film increased slightly from 0.45 to 0.53 nm. The amorphization time for Ge10Sb90 (1 nm)/SiO2 (9 nm) thin film (2.29 ns) is shorter than Ge2Sb2Te5 (3.56 ns). The threshold voltage of a cell based on Ge10Sb90 (1 nm)/SiO2 (9 nm) (3.57 V) was smaller than GST (4.18 V). The results indicated that Ge10Sb90/SiO2 was a promising phase change thin film with high thermal ability and low power consumption for phase change memory application.

  5. Comparison of two peptide radiotracers for prostate carcinoma targeting

    Directory of Open Access Journals (Sweden)

    Bluma Linkowski Faintuch

    2012-01-01

    Full Text Available OBJECTIVES: Scintigraphy is generally not the first choice treatment for prostate cancer, although successful studies using bombesin analog radiopeptides have been performed. Recently, a novel peptide obtained using a phage display library demonstrated an affinity for prostate tumor cells. The aim of this study was to compare the use of a bombesin analog to that of a phage display library peptide (DUP-1 radiolabeled with technetium-99m for the treatment of prostate carcinoma. The peptides were first conjugated to S-acetyl-MAG3 with a 6-carbon spacer, namely aminohexanoic acid. METHODS: The technetium-99m labeling required a sodium tartrate buffer. Radiochemical evaluation was performed using ITLC and was confirmed by high-performance liquid chromatography. The coefficient partition was determined, and in vitro studies were performed using human prostate tumor cells. Biodistribution was evaluated in healthy animals at various time points and also in mice bearing tumors. RESULTS: The radiochemical purity of both radiotracers was greater than 95%. The DUP-1 tracer was more hydrophilic (log P = -2.41 than the bombesin tracer (log P = -0.39. The biodistribution evaluation confirmed this hydrophilicity by revealing the greater kidney uptake of DUP-1. The bombesin concentration in the pancreas was greater than that of DUP-1 due to specific gastrin-releasing peptide receptors. Bombesin internalization occurred for 78.32% of the total binding in tumor cells. The DUP-1 tracer showed very low binding to tumor cells during the in vitro evaluation, although tumor uptake for both tracers was similar. The tumors were primarily blocked by DUP1 and the bombesin radiotracer primarily targeted the pancreas. CONCLUSION: Further studies with the radiolabeled DUP-1 peptide are recommended. With further structural changes, this molecule could become an efficient alternative tracer for prostate tumor diagnosis.

  6. Isomeric rations study for the α + 70 Ge

    International Nuclear Information System (INIS)

    Hora Villano, M.H. da.

    1984-12-01

    Isomeric ratios for 73 Se F,I produced in the reaction α + 70 Ge with incidence laboratory energy ranging from 8 to 28 MeV, have been measured using off-line γ-ray spectroscopy. Relative formation cross-section for isomeric and ground states were obtained with NAT Ge targets. Compound nucleus statistical analyses were performed using computer codes Alice and Julian. Unlike to Alice code, the Julian code predictions agreed quite well with the experimental results. This agreement may be explained by the inclusion of the γ competition in the deexcitation channels of the compound nucleus and by the correct level density calculation of the emission probabilities in the Julian code. Finally angular momentum populations for isomers formations in the reaction 70 Ge(α, n) 73 have been determined. (author)

  7. Novel methodology for the study of mercury methylation and reduction in sediments and water using {sup 197}Hg radiotracer

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro Guevara, Sergio; Perez Catan, Soledad [Centro Atomico Bariloche, Laboratorio de Analisis por Activacion Neutronica, Bariloche (Argentina); Zizek, Suzana; Repinc, Urska; Jacimovic, Radojko; Horvat, Milena [Jozef Stefan Institute, Department of Environmental Sciences, Ljubljana (Slovenia)

    2007-03-15

    Mercury tracers are powerful tools that can be used to study mercury transformations in environmental systems, particularly mercury methylation, demethylation and reduction in sediments and water. However, mercury transformation studies using tracers can be subject to error, especially when used to assess methylation potential. The organic mercury extracted can be as low as 0.01% of the endogenous labeled mercury, and artefacts and contamination present during methylmercury (MeHg) extraction processes can cause interference. Solvent extraction methods based on the use of either KBr/H{sub 2}SO{sub 4} or HCl were evaluated in freshwater sediments using {sup 197}Hg radiotracer. Values obtained for the {sup 197}Hg tracer in the organic phase were up to 25-fold higher when HCl was used, which is due to the coextraction of {sup 197}Hg{sup 2+} into the organic phase during MeHg extraction. Evaluations of the production of MeHg gave similar results with both MeHg extraction procedures, but due to the higher Hg{sup 2+} contamination of the controls, the uncertainty in the determination was higher when HCl was used. The Hg{sup 2+} contamination of controls in the HCl extraction method showed a nonlinear correlation with the humic acid content of sediment pore water. Therefore, use of the KBr/H{sub 2}SO{sub 4} method is recommended, since it is free from these interferences. {sup 197}Hg radiotracer (T{sub 1/2} = 2.673 d) has a production rate that is about 50 times higher than that of {sup 203}Hg (T{sub 1/2} = 46.595 d), the most frequently used mercury radiotracer. Hence it is possible to obtain a similar level of performance to {sup 203}Hg when it is used it in short-term experiments and produced by the irradiation of {sup 196}Hg with thermal neutrons, using mercury targets with the natural isotopic composition. However, if the 0.15% natural abundance of the {sup 196}Hg isotope is increased, the specific activity of the {sup 197}Hg tracer can be significantly improved. In

  8. SR-71 Pilot Stephen (Steve) D. Ishmael

    Science.gov (United States)

    1992-01-01

    NASA research pilot Stephen D. Ishmael is pictured here in front of an SR-71 Blackbird on the ramp at the Dryden Flight Research Center, Edwards, California. Ishmael was one of two NASA research pilots assigned to the SR-71 high speed research program in the early 1990s at NASA's Dryden Flight Research Facility (redesignated the Dryden Flight Research Center in 1994), Edwards, California. Ishmael became a NASA research pilot in 1977. Data from the SR-71 program will be used to aid designers of future supersonic aircraft and propulsion systems. Two SR-71 aircraft have been used by NASA as testbeds for high-speed and high-altitude aeronautical research. The aircraft, an SR-71A and an SR-71B pilot trainer aircraft, have been based here at NASA's Dryden Flight Research Center, Edwards, California. They were transferred to NASA after the U.S. Air Force program was cancelled. As research platforms, the aircraft can cruise at Mach 3 for more than one hour. For thermal experiments, this can produce heat soak temperatures of over 600 degrees Fahrenheit (F). This operating environment makes these aircraft excellent platforms to carry out research and experiments in a variety of areas -- aerodynamics, propulsion, structures, thermal protection materials, high-speed and high-temperature instrumentation, atmospheric studies, and sonic boom characterization. The SR-71 was used in a program to study ways of reducing sonic booms or over pressures that are heard on the ground, much like sharp thunderclaps, when an aircraft exceeds the speed of sound. Data from this Sonic Boom Mitigation Study could eventually lead to aircraft designs that would reduce the 'peak' overpressures of sonic booms and minimize the startling affect they produce on the ground. One of the first major experiments to be flown in the NASA SR-71 program was a laser air data collection system. It used laser light instead of air pressure to produce airspeed and attitude reference data, such as angle of attack and

  9. 7 CFR 1001.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ... skim milk and butterfat for which a value was computed pursuant to § 1001.60(h) by the producer price... producer price differential and the statistical uniform price pursuant to § 1001.62 (except as provided for... the producer price differential as adjusted pursuant to § 1001.75; (2) An amount obtained by...

  10. Reduced thermal conductivity due to scattering centers in p-type SiGe alloys

    International Nuclear Information System (INIS)

    Beaty, J.S.; Rolfe, J.L.; Vandersande, J.; Fleurial. J.P.

    1992-01-01

    This paper reports that a theoretical model has been developed that predicts that the addition of ultra-fine, inert, phonon-scattering centers to SiGe thermoelectric material will reduce its thermal conductivity and improve its figure-of-merit. To investigate this prediction, ultra-fine particulates (20 Angstrom to 200 Angstrom) of boron nitride have been added to boron doped, p-type, 80/20 SiGe. All previous SiGe samples produced from ultra-fine SiGe powder without additions had lower thermal conductivities than standard SiGe, but high temperature (1525 K) heat treatment increased their thermal conductivity back to the value for standard SiGe. Transmission Electron Microscopy has been used to confirm the presence of occluded particulates and X-ray diffraction has been used to determine the composition to be BN

  11. Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [18F]MNI-698

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Caillé, Fabien; Barret, Olivier; Papin, Caroline; Lee, Hsiaoju; Morley, Thomas J.; Fowles, Krista; Holden, Daniel; Seibyl, John P.; Alagille, David; Tamagnan, Gilles D.

    2014-01-01

    Introduction: A new radiotracer for imaging the serotonin 4 receptors (5-HT 4 ) in brain, [ 18 F]MNI-698, was recently developed by our group. Evaluation in nonhuman primates indicates the novel radiotracer holds promise as an imaging agent of 5-HT 4 in brain. This paper aims to describe the whole-body biodistribution and dosimetry estimates of [ 18 F]MNI-698. Methods: Whole-body positron emission tomography (PET) images were acquired over 240 minutes after intravenous bolus injection of [ 18 F]MNI-698 in adult rhesus monkeys. Different models were investigated for quantification of radiation absorbed and effective doses using OLINDA/EXM 1.0 software. Results: The radiotracer main elimination route was found to be urinary and the critical organ was the urinary bladder. Modeling of the urinary bladder voiding interval had a considerable effect on the estimated effective dose. Normalization of rhesus monkeys’ organs and whole-body masses to human equivalent reduced the calculated dosimetry values. The effective dose ranged between 0.017 and 0.027 mSv/MBq. Conclusion: The dosimetry estimates, obtained when normalizing organ and whole-body weights and applying the urinary bladder model, indicate that the radiation doses from [ 18 F]MNI-698 comply with limits and guidelines recommended by key regulatory authorities that govern the translation of radiotracers to human clinical trials. The timing of urinary bladder emptying should be considered when designing future clinical protocols with [ 18 F]MNI-698, in order to minimize the subject absorbed doses

  12. Ethanol and water adsorption in methanol-derived ZIF-71

    KAUST Repository

    Lively, Ryan P.; Dose, Michelle E.; Thompson, Joshua A.; McCool, Benjamin A.; Chance, Ronald R.; Koros, William J.

    2011-01-01

    A room temperature method for synthesizing zeolitic imidizolate framework 71 (ZIF-71) is described. The methanol-based synthesis results in >95% yields (based on Zn) and produces crystals with 70% greater surface area than reported earlier. Ethanol uptake into the ZIF compares favorably with a recent modeling-based study. Water uptake was significantly higher than model predictions. © The Royal Society of Chemistry 2011.

  13. Non-destructive investigation of technical plants and processes and natural processes by short-lived radionuclides (radiotracer)

    International Nuclear Information System (INIS)

    Jentsch, Thorsten; Zeuner, Albert

    2009-01-01

    Short lived open radionuclides are very suitable to investigate transport and mixing processes. They do not pollute the product. After decay of the radionuclide, the product can be used without any restrictions. Examples are showed for technical processes investigation by aid of radiotracer. (orig.)

  14. Novel Au- and Ge-based two-dimensional materials formed through topotactic transitions of AlB2-like structures

    Science.gov (United States)

    Tsetseris, Leonidas

    2016-07-01

    The topotactic reaction of a layered compound, for example CaGe2, with HCl solution is a common and facile method to produce two-dimensional (2D) materials. In this work we demonstrate with first-principles calculations that this technique can potentially lead to a whole new family of 2D materials starting from three-dimensional crystals with AlB2-like structures. As representative cases, we show here that the de-intercalation of Sc and Ca atoms from ScAuGe and Ca2AuGe3 crystals is strongly exothermic and produces the stable 2D monolayers AuGeH and AuGe3H3, respectively. Remarkably, both metals (AuGeH) and semiconductors (AuGe3H3) can be prepared by this method. Based on the broad availability of AlB2-like structures with varying stoichiometries, there are several possibilities to prepare novel functional 2D materials with suitable topotactic transitions.

  15. Special aspects of the indirect radiotracer technique when used to study the adsorption and electrochemical reactions of organic substances at solid electrodes

    International Nuclear Information System (INIS)

    Andreev, V.N.; Horanyi, G.; Kazarinov, V.E.

    1986-01-01

    This paper analyzes the possibilities and special aspects of the indirect radiotracer technique with a number of examples. Data are presented concerning the effects of acetic and oxalic acid on chloride ion adsorption on platinized platinum electrodes at a potential E = 0.2 V. The effect on chloride ion adsorption is much larger in the case of oxalic acid, which is evidence for its higher adsorbability on platinum at E = 0.2 V. It is shown that the indirect radiotracer technique offers significant possibilities for studying the electrochemical properties of adsorption products of organic substances

  16. 7-GeV Advanced Photon Source Conceptual Design Report

    International Nuclear Information System (INIS)

    1987-04-01

    During the past decade, synchrotron radiation emitted by circulating electron beams has come into wide use as a powerful, versatile source of x-rays for probing the structure of matter and for studying various physical processes. Several synchrotron radiation facilities with different designs and characteristics are now in regular operation throughout the world, with recent additions in this country being the 0.8-GeV and 2.5-GeV rings of NSLS at Brookhaven National Laboratory. However, none of the operating facilities has been designed to use a low-emittance, high-energy stored beam, together with modern undulator devices, to produce a large number of hard x-ray beams of extremely high brilliance. This document is a proposal to the Department of Energy to construct and operate high-energy synchrotron radiation facility at Argonne National Laboratory. We have now chosen to set the design energy of this facility at 7.0 GeV, with the capability to operate at up to 7.5 GeV

  17. [11C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    International Nuclear Information System (INIS)

    Wilson, Alan A.; Garcia, Armando; Parkes, Jun; Houle, Sylvain; Tong, Junchao; Vasdev, Neil

    2011-01-01

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([ 11 C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [ 11 C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [ 11 C]CURB was irreversibly bound to FAAH. Conclusions

  18. Pseudomorphic GeSiSn, SiSn and Ge layers in strained heterostructures

    Science.gov (United States)

    Timofeev, V. A.; Nikiforov, A. I.; Tuktamyshev, A. R.; Mashanov, V. I.; Loshkarev, I. D.; Bloshkin, A. A.; Gutakovskii, A. K.

    2018-04-01

    The GeSiSn, SiSn layer growth mechanisms on Si(100) were investigated and the kinetic diagrams of the morphological GeSiSn, SiSn film states in the temperature range of 150 °C-450 °C at the tin content from 0% to 35% were built. The phase diagram of the superstructural change on the surface of Sn grown on Si(100) in the annealing temperature range of 0 °C-850 °C was established. The specular beam oscillations were first obtained during the SiSn film growth from 150 °C to 300 °C at the Sn content up to 35%. The transmission electron microscopy and x-ray diffractometry data confirm the crystal perfection and the pseudomorphic GeSiSn, SiSn film state, and also the presence of smooth heterointerfaces between GeSiSn or SiSn and Si. The photoluminescence for the multilayer periodic GeSiSn/Si structures in the range of 0.6-0.8 eV was detected. The blue shift with the excitation power increase is observed suggesting the presence of a type II heterostructure. The creation of tensile strained Ge films, which are pseudomorphic to the underlying GeSn layer, is confirmed by the results of the formation and analysis of the reciprocal space map in the x-ray diffractometry. The tensile strain in the Ge films reached the value in the range of 0.86%-1.5%. The GeSn buffer layer growth in the Sn content range from 8% to 12% was studied. The band structure of heterosystems based on pseudomorphic GeSiSn, SiSn and Ge layers was calculated and the valence and conduction band subband position dependences on the Sn content were built. Based on the calculation, the Sn content range in the GeSiSn, SiSn, and GeSn layers, which corresponds to the direct bandgap GeSiSn, SiSn, and Ge material, was obtained.

  19. Method of producing buried porous silicon-geramanium layers in monocrystalline silicon lattices

    Science.gov (United States)

    Fathauer, Robert W. (Inventor); George, Thomas (Inventor); Jones, Eric W. (Inventor)

    1997-01-01

    Lattices of alternating layers of monocrystalline silicon and porous silicon-germanium have been produced. These single crystal lattices have been fabricated by epitaxial growth of Si and Si--Ge layers followed by patterning into mesa structures. The mesa structures are stain etched resulting in porosification of the Si--Ge layers with a minor amount of porosification of the monocrystalline Si layers. Thicker Si--Ge layers produced in a similar manner emitted visible light at room temperature.

  20. Development of Novel Vaccines against Enterovirus-71

    Science.gov (United States)

    Yee, Pinn Tsin Isabel; Poh, Chit Laa

    2015-01-01

    The hand, foot and mouth disease is caused by a group of Enteroviruses such as Enterovirus 71 (EV-A71) and Coxsackievirus CV-A5, CV-A8, and CV-A16. Mild symptoms of EV-A71 infection in children range from high fever, vomiting, rashes and ulcers in mouth but can produce more severe symptoms such as brainstem and cerebellar encephalitis, leading up to cardiopulmonary failure and death. The lack of vaccines and antiviral drugs against EV-A71 highlights the urgency of developing preventive and treatment agents against EV-A71 to prevent further fatalities. Research groups have developed experimental inactivated vaccines, recombinant Viral Protein 1 (VP1) vaccine and virus-like particles (VLPs). The inactivated EV-A71 vaccine is considered the safest viral vaccine, as there will be no reversion to the infectious wild type strain. The recombinant VP1 vaccine is a cost-effective immunogen, while VLPs contain an arrangement of epitopes that can elicit neutralizing antibodies against the virus. As each type of vaccine has its advantages and disadvantages, increased studies are required in the development of such vaccines, whereby high efficacy, long-lasting immunity, minimal risk to those vaccinated, safe and easy production, low cost, dispensing the need for refrigeration and convenient delivery are the major goals in their design. PMID:26729152

  1. Ge nitride formation in N-doped amorphous Ge2Sb2Te5

    International Nuclear Information System (INIS)

    Jung, M.-C.; Lee, Y. M.; Kim, H.-D.; Kim, M. G.; Shin, H. J.; Kim, K. H.; Song, S. A.; Jeong, H. S.; Ko, C. H.; Han, M.

    2007-01-01

    The chemical state of N in N-doped amorphous Ge 2 Sb 2 Te 5 (a-GST) samples with 0-14.3 N at. % doping concentrations was investigated by high-resolution x-ray photoelectron spectroscopy (HRXPS) and Ge K-edge x-ray absorption spectroscopy (XAS). HRXPS showed negligible change in the Te 4d and Sb 4d core-level spectra. In the Ge 3d core-level spectra, a Ge nitride (GeN x ) peak developed at the binding energy of 30.2 eV and increased in intensity as the N-doping concentration increased. Generation of GeN x was confirmed by the Ge K-edge absorption spectra. These results indicate that the N atoms bonded with the Ge atoms to form GeN x , rather than bonding with the Te or Sb atoms. It has been suggested that the formation of Ge nitride results in increased resistance and phase-change temperature

  2. Investigation of leaching of an antifouling agent from marine paint formulations using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Kalgutkar, D.B.; Patil, S.P.; Jayachandran, N.; Unni, V.K.P.

    2012-01-01

    A radiotracer technique was used to investigate the leaching of an antifouling agent from different marine paint formulations with an objective to select the best paint formulation for bulk production. The antifouling agent (Diuron) itself was labeled with carbon-14 (half-life: 5,730 years, β-energy: 156 keV) and used as a radiotracer. The different paint formulations added with radiolabeled Diuron were applied onto suitably selected substrates and measured for initial intensity of β-radiation using a Geiger-Muller detector connected to a ratemeter. The painted substrates were subjected to shower tests for a pre-decided time and subsequently measured for β-radiations. The comparison of intensity of β-radiations in substrates prior and post shower tests provides information about leaching of antifouling agent Diuron from the paint formulation. The high leaching percentage of antifouling agent Diuron post shower tests indicates non-suitability of paint formulation for marine and civil structures. However, low leaching rate of Diuron will make a paint formulation more efficient and suitable. Based on the results of investigation, a paint formulation with minimum leaching rate was identified and selected for bulk production by a paint company. (author)

  3. Photoreflectance Spectroscopy Characterization of Ge/Si0.16Ge0.84 Multiple Quantum Wells on Ge Virtual Substrate

    Directory of Open Access Journals (Sweden)

    Hung-Pin Hsu

    2013-01-01

    Full Text Available We report a detailed characterization of a Ge/Si0.16Ge0.84 multiple quantum well (MQW structure on Ge-on-Si virtual substrate (VS grown by ultrahigh vacuum chemical vapor deposition by using temperature-dependent photoreflectance (PR in the temperature range from 10 to 300 K. The PR spectra revealed a wide range of optical transitions from the MQW region as well as transitions corresponding to the light-hole and heavy-hole splitting energies of Ge-on-Si VS. A detailed comparison of PR spectral line shape fits and theoretical calculation led to the identification of various quantum-confined interband transitions. The temperature-dependent PR spectra of Ge/Si0.16Ge0.84 MQW were analyzed using Varshni and Bose-Einstein expressions. The parameters that describe the temperature variations of various quantum-confined interband transition energies were evaluated and discussed.

  4. Amorphization threshold in Si-implanted strained SiGe alloy layers

    International Nuclear Information System (INIS)

    Simpson, T.W.; Love, D.; Endisch, E.; Goldberg, R.D.; Mitchell, I.V.; Haynes, T.E.; Baribeau, J.M.

    1994-12-01

    The authors have examined the damage produced by Si-ion implantation into strained Si 1-x Ge x epilayers. Damage accumulation in the implanted layers was monitored in situ by time-resolved reflectivity and measured by ion channeling techniques to determine the amorphization threshold in strained Si 1-x Ge x (x = 0.16 and 0.29) over the temperature range 30--110 C. The results are compared with previously reported measurements on unstrained Si 1-x Ge x , and with the simple model used to describe those results. They report here data which lend support to this model and which indicate that pre-existing strain does not enhance damage accumulation in the alloy layer

  5. Blood circulation of the inner ear under the influence of medications. Radiotracer experiments using guinea pig cochlea

    International Nuclear Information System (INIS)

    Neumeier, A.

    1987-01-01

    The dependence of the blood circulation in the inner ear on various medications is discussed. By means of a radiotracer clearance technique the cochlear clearance curves for the guinea pig cochlea after the administration of various circulation stimulants were determined. (MBC) [de

  6. Uses and limits of radiotracers in the study of drugs and xenobiotics metabolism

    International Nuclear Information System (INIS)

    Cohen, Y.

    1980-01-01

    This review deals with scientific papers issued in 1977-1978, on labelling of drugs and xenobiotics and their metabolism. It is divided in five parts: site of label; in vivo metabolism in animals and human beings; in vitro metabolism on tissue slices, cells culture, microsomes, membrane receptors; metabolism of xenobiotics: nutrients, food additives, detergents, plastics and fabrics; discussion. Metabolic studies, nowadays, associate radiotracers, stable isotopes with high performing procedures for analytical separation [fr

  7. Impact of genetic changes, pathogenicity and antigenicity on Enterovirus- A71 vaccine development.

    Science.gov (United States)

    Yee, Pinn Tsin Isabel; Laa Poh, Chit

    2017-06-01

    Enterovirus-A71 (EV-A71) is an etiological agent of the hand, foot and mouth disease (HFMD). EV-A71 infection produces high fever and ulcers in children. Some EV-A71 strains produce severe infections leading to pulmonary edema and death. Although the protective efficacy of the inactivated vaccine (IV) was ≥90% against mild HFMD, there was approximately 80% protection against severe HFMD. The monovalent EV-A71 IV elicits humoral immunity but lacks long-term immunogenicity. Spontaneous mutations of the EV-A71 genome could lead to antigenicity changes and the virus may not be neutralized by antibodies elicited by the IV. A better alternative would be the live attenuated vaccine (LAV) that elicits cellular and humoral immunity. The LAV induces excellent antigenicity and chances of reversion is reduced by presence of multiple mutations which could reduce pathogenicity. Besides CV-A16, outbreaks have been caused by CV-A6 and CV-A10, hence the development of bivalent and trivalent vaccines is required. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Effect of Ge Content on the Formation of Ge Nanoclusters in Magnetron-Sputtered GeZrOx-Based Structures

    OpenAIRE

    Khomenkova, L.; Lehninger, D.; Kondratenko, O.; Ponomaryov, S.; Gudymenko, O.; Tsybrii, Z.; Yukhymchuk, V.; Kladko, V.; von Borany, J.; Heitmann, J.

    2017-01-01

    Ge-rich ZrO2 films, fabricated by confocal RF magnetron sputtering of pure Ge and ZrO2 targets in Ar plasma, were studied by multi-angle laser ellipsometry, Raman scattering, Auger electron spectroscopy, Fourier transform infrared spectroscopy, and X-ray diffraction for varied deposition conditions and annealing treatments. It was found that as-deposited films are homogeneous for all Ge contents, thermal treatment stimulated a phase separation and a formation of crystalline Ge and ZrO2. The ?...

  9. Addition of Mn to Ge quantum dot surfaces—interaction with the Ge QD {105} facet and the Ge(001) wetting layer

    International Nuclear Information System (INIS)

    Nolph, C A; Kassim, J K; Floro, J A; Reinke, P

    2013-01-01

    The interaction of Mn with Ge quantum dots (QD), which are bounded by {105} facets, and the strained Ge wetting layer (WL), terminated by a (001) surface, is investigated with scanning tunneling microscopy (STM). These surfaces constitute the growth surfaces in the growth of Mn-doped QDs. Mn is deposited on the Ge QD and WL surface in sub-monolayer concentrations, and subsequently annealed up to a temperature of 400 ° C. The changes in bonding and surface topography are measured with STM during the annealing process. Mn forms flat islands on the Ge{105} facet, whose shape and position are guided by the rebonded step reconstruction of the facet. Voltage-dependent STM images reflect the Mn-island interaction with the empty and filled states of the Ge{105} reconstruction. Scanning tunneling spectra (STS) of the Ge{105} facet and as-deposited Mn-islands show a bandgap of 0.8 eV, and the Mn-island spectra are characterized by an additional empty state at about 1.4 eV. A statistical analysis of Mn-island shape and position on the QD yields a slight preference for edge positions, whereas the QD strain field does not impact Mn-island position. However, the formation of ultra-small Mn-clusters dominates on the Ge(001) WL, which is in contrast to Mn interaction with unstrained Ge(001) surfaces. Annealing to T 5 Ge 3 from a mass balance analysis. This reaction is accompanied by the disappearance of the original Mn-surface structures and de-wetting of Mn is complete. This study unravels the details of Mn–Ge interactions, and demonstrates the role of surface diffusion as a determinant in the growth of Mn-doped Ge materials. Surface doping of Ge-nanostructures at lower temperatures could provide a pathway to control magnetism in the Mn–Ge system. (paper)

  10. Dipole Resonances of 76Ge

    Science.gov (United States)

    Ilieva, R. S.; Cooper, N.; Werner, V.; Rusev, G.; Pietralla, N.; Kelly, J. H.; Tornow, W.; Yates, S. W.; Crider, B. P.; Peters, E.

    2013-10-01

    Dipole resonances in 76Ge have been studied using the method of Nuclear Resonance Fluorescence (NRF). The experiment was performed using the Free Electron Laser facility at HI γS/TUNL, which produced linearly polarised quasi-monoenergetic photons in the 4-9 MeV energy range. Photon strength, in particular dipole strength, is an important ingredient in nuclear reaction calculations, and recent interest in its study has been stimulated by observations of a pygmy dipole resonance near the neutron separation energy Sn of certain nuclei. Furthermore, 76Ge is a candidate for 0 ν 2 β -decay. The results are complimentary to a relevant experiment done at TU Darmstadt using Bremsstrahlung beams. Single-resonance parities and a preliminary estimate of the total photo-excitation cross section will be presented. This work was supported by the U.S. DOE under grant no. DE-FG02-91ER40609.

  11. 40 CFR 71.10 - Delegation of part 71 program.

    Science.gov (United States)

    2010-07-01

    ... compatible with EPA's national database management system. (2) The Administrator may waive the requirements... (CONTINUED) FEDERAL OPERATING PERMIT PROGRAMS Operating Permits § 71.10 Delegation of part 71 program. (a... authority, the authority to administer a part 71 operating permits program to a State, eligible Tribe, local...

  12. Absorption and retention studies of trace elements and minerals in rats using radiotracers and whole-body counting

    NARCIS (Netherlands)

    Berg, van den G.J.; Wolterbeek, H.Th.; de Goeij, J.J.M.; Beynen, A.C.

    1995-01-01

    A description is given of a whole-body counting technique using radiotracers, permitting the determination of true absorption and endogenous excretion of trace elements and minerals in the rat in vivo. This non-invasive counting method involves oral and intraperitoneal administration of tracer doses

  13. Isothermal cross-sections of Sr-Al-Ge and Ba-Al-Ge systems at 673 K

    International Nuclear Information System (INIS)

    Kutsenok, N.L.; Yanson, T.I.

    1987-01-01

    X-ray and microstructural analyses are used to study phase equilibria in Sr-Al-Ge and Ba-Al-Ge systems. Existence of SrAl 2 Ge 2 , Sr(Al, Ge) 2 Ba(Al, Ge) 2 , Sr 3 Al 2 Ge 2 , Ba 3 Al 2 Ge 2 ternary compounds is confirmed, a new BaGe 4 binary compound and also new ternary compounds of approximate composition Sr 57 Al 30 Ge 13 and Ba 20 Al 40 Ge 40 , which crystal structure is unknown, are detected. Aluminium solubility in SrAl 4 and BaAl 4 binary compounds (0.05 atomic fraction) is determined. Ba(Al, Ge) 2 compound homogeneity region is defined more exactly (aluminium content varies from 0.27 to 0.51 at. fractions)

  14. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a vacuum pan for massecuite b and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the o n line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  15. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a Vacuum Pan for massecuite B and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the Ion Line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  16. Growth of Ferromagnetic Epitaxial Film of Hexagonal FeGe on (111) Ge Surface

    Science.gov (United States)

    Kumar, Dushyant; Joshi, P. C.; Hossain, Z.; Budhani, R. C.

    2014-03-01

    The realization of semiconductors showing ferromagnetic order at easily accessible temperatures has been of interest due to their potential use in spintronic devices where long spin life times are of key interest. We have realized the growth of FeGe thin films on Ge (111) wafers using pulsed laser deposition (PLD). The stoichiometric and single phase FeGe target used in PLD chamber has been made by arc melting. A typical θ-2 θ diffraction spectra performed on 40 nm thick FeGe film suggests the stabilization of β-Ni2In (B82-type) hexagonal phase with an epitaxial orientation of (0001)FeGe ||(111)Ge and [11-20]FeGe ||[-110]Ge. SEM images shows a granular structure with the formation of very large grains of about 100 to 500 nm in lateral dimension. The magnetization vs. temperature data taken from SQUID reveal the TC of ~ 270K. Since, PLD technique makes it easier to stabilize the B82 (Ni2In) hexagonal phase in thin FeGe films, this work opens opportunities to reinvestigate many conflicting results on various properties of the FeGe system.

  17. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Radionuclide dosimetry must, by its nature, define tissue irradiation in terms of mean exposure in a population of a statistically acceptable size. In the daily practice of clinical nuclear medicine there are, however, quite large variations in the biodistribution of tracers and thus in resulting radiation doses. Age is a variable, particularly in respect of bone-seeking tracers. Sex imposes variations in radiation dose on account of the differing anatomical configurations of the gonads. Breast uptake and excretion of certain tracers in women are additional variables. Activity and occupation are occasional variables. Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggest that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  18. Photoreflectance Spectroscopy Characterization of Ge/Si0.16Ge0.84 Multiple Quantum Wells on Ge Virtual Substrate

    OpenAIRE

    Hsu, Hung-Pin; Yang, Pong-Hong; Huang, Jeng-Kuang; Wu, Po-Hung; Huang, Ying-Sheng; Li, Cheng; Huang, Shi-Hao; Tiong, Kwong-Kau

    2013-01-01

    We report a detailed characterization of a Ge/Si0.16Ge0.84 multiple quantum well (MQW) structure on Ge-on-Si virtual substrate (VS) grown by ultrahigh vacuum chemical vapor deposition by using temperature-dependent photoreflectance (PR) in the temperature range from 10 to 300 K. The PR spectra revealed a wide range of optical transitions from the MQW region as well as transitions corresponding to the light-hole and heavy-hole splitting energies of Ge-on-Si VS. A detailed comparison of PR spec...

  19. [{sup 11}C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Alan A., E-mail: alan.wilson@camhpet.c [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Garcia, Armando; Parkes, Jun [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Houle, Sylvain [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Tong, Junchao [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5T 1R8 (Canada); Vasdev, Neil [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada)

    2011-02-15

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([{sup 11}C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [{sup 11}C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [{sup 11}C]CURB was irreversibly bound to FAAH

  20. Improvement of photoneutron spectrum measurement produced by bombardment of 2 GeV electrons above giant dipole resonance region

    International Nuclear Information System (INIS)

    Lee, H. S.; Park, J. S.; Choi, H. D.; Sato, Tatsuhiko; Shin, Kasuo; Ban, Syuichi

    2000-01-01

    Above the Giant Dipole Resonance (GDR) region, high energy photoneutron spectra produced by irradiation of 2.04 GeV electrons into Pb target were measured by Time-of-Flight (TOF) technique. The differential photoneutron yields were obtained at a fixed angle of 90 degrees to the electron beam direction. The TOF system consists of Pilot-U plastic scintillation detector, which has fast response time, and the high speed multiscaler or CAMAC TDC. In the improvement of experimental setup to extend the flight distance to 10.4 m lead to make the measurable energy to 500 MeV from 300 MeV. And using the TDC based electronics lead to use a veto counter. The results were compared with the calculated one by using EGS4 and Modified PICA95. The characteristics of this TOF system was introduced in this paper and the results for several measuring conditions, which are flight distance, TOF electronics, and type of neutron detector, were discussed to improve the accuracy of this measurement

  1. Radiotracer study on dispersion of sewerage off Mumbai Coast in Western India

    International Nuclear Information System (INIS)

    Kumar, U.S.; Yelgaonkar, V.N.; Navada, S.V.

    1997-01-01

    Municipal Corporation of Greater Mumbai discharges the treated sewage at various locations off Mumbai coast. One such discharge point is located near Colaba near South Mumbai. Screened, degritted and aerated sewage is discharged through a 1 m diameter steel pipe by gravity to the diffuser installed on the sea bed at 1.1 km away from the shore. A radiotracer study was carried out to evaluate the dilution and dispersion pattern of the sewage at different points from the disposal point. The experiment was carried out during high tide. About 110 GBq of 82 Br was used as the tracer. A dilution factor of about 5.5 x 10 3 was obtained at a distance of 4.3 km from the outfall. The dilution downshore was small even for a long distance due to strong unidirectional currents. Comparable dilution factors were also obtained by Brooks' model. Vertical tracer profiles showed that the waste plume was well mixed over a depth of 2 to 3 m from the surface. A 2-D advection simulation model was employed to simulate the spatial and temporal distribution of the radiotracer data. From the model simulation best fit was obtained for dispersion coefficients Dx = 15 m 2 .s -1 and Dy = 2m 2 .s -1 . The dispersion coefficients can be used for predicting the effluent dispersion under different outfall and disposal conditions. The tracer pattern at Colaba and Malad indicated no possibility of contamination of the beaches

  2. Fabrication of SrGe2 thin films on Ge (100), (110), and (111) substrates

    Science.gov (United States)

    Imajo, T.; Toko, K.; Takabe, R.; Saitoh, N.; Yoshizawa, N.; Suemasu, T.

    2018-01-01

    Semiconductor strontium digermanide (SrGe2) has a large absorption coefficient in the near-infrared light region and is expected to be useful for multijunction solar cells. This study firstly demonstrates the formation of SrGe2 thin films via a reactive deposition epitaxy on Ge substrates. The growth morphology of SrGe2 dramatically changed depending on the growth temperature (300-700 °C) and the crystal orientation of the Ge substrate. We succeeded in obtaining single-oriented SrGe2 using a Ge (110) substrate at 500 °C. Development on Si or glass substrates will lead to the application of SrGe2 to high-efficiency thin-film solar cells.

  3. UV-photochemical vapor generation of selenium for atomic absorption spectrometry: Optimization and 75Se radiotracer efficiency study

    Czech Academy of Sciences Publication Activity Database

    Rybínová, M.; Musil, Stanislav; Červený, J.; Vobecký, Miloslav; Rychlovský, P.

    2016-01-01

    Roč. 123, SEP (2016), s. 134-142 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Institutional support: RVO:68081715 Keywords : UV-photochemical vapor generation * Selenium * 75Se radiotracer Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.241, year: 2016

  4. Chemistry and biology of radiotracers that target changes in sympathetic and parasympathetic nervous systems in heart disease.

    Science.gov (United States)

    Eckelman, William C; Dilsizian, Vasken

    2015-06-01

    Following the discovery of the sympathetic and parasympathetic nervous system, numerous adrenoceptor drugs were radiolabeled and potent radioligands were prepared in order to image the β-adrenergic and the muscarinic systems. But the greatest effort has been in preparing noradrenaline analogs, such as norepinephrine, (11)C-metahydroxyephedrine, and (123)I-metaiodobenzylguanidine that measure cardiac sympathetic nerve varicosities. Given the technical and clinical challenges in designing and validating targeted adrenoceptor-binding radiotracers, namely the heavily weighted flow dependence and relatively low target-to-background ratio, both requiring complicated mathematic analysis, and the inability of targeted adrenoceptor radioligands to have an impact on clinical care of heart disease, the emphasis has been on radioligands monitoring the norepinephrine pathway. The chemistry and biology of such radiotracers, and the clinical and prognostic impact of these innervation imaging studies in patients with heart disease, are examined. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Strain distribution of confined Ge/GeO2 core/shell nanoparticles engineered by growth environments

    Science.gov (United States)

    Wei, Wenyan; Yuan, Cailei; Luo, Xingfang; Yu, Ting; Wang, Gongping

    2016-02-01

    The strain distributions of Ge/GeO2 core/shell nanoparticles confined in different host matrix grown by surface oxidation are investigated. The simulated results by finite element method demonstrated that the strains of the Ge core and the GeO2 shell strongly depend on the growth environments of the nanoparticles. Moreover, it can be found that there is a transformation of the strain on Ge core from tensile to compressive strain during the growth of Ge/GeO2 core/shell nanoparticles. And, the transformation of the strain is closely related with the Young's modulus of surrounding materials of Ge/GeO2 core/shell nanoparticles.

  6. Report of the Consultants’ Meeting on the “Establishment of a training and certification system for radiotracers and NCS applications”. Proceedings of a conference

    International Nuclear Information System (INIS)

    2013-01-01

    The International Atomic Energy Agency (IAEA) has been playing a major role in facilitating the transfer of the radiotracer and sealed sources technologies to developing Member States. The major techniques have been implemented through IAEA Technical Co-operation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for education of specialists in different fields of nuclear technologies. Training course materials on the radiotracer and sealed sources methods for industrial and environmental applications have been developed for the cultivation of radiation technologies specialists and for continuing technical education of practitioners worldwide. The wide interest in radiotracer technology has created the need for highlevel professional education and training in this field, which are not necessarily covered by traditional University courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Beside this academic teaching aspect, it appears the need to create a structured training system, mainly for practitioners to ensure sustainability of the activity and to improve the recognition of the technologies and personal by the industries

  7. ISABELLE: a 200 + 200 GeV colliding beam facility

    International Nuclear Information System (INIS)

    Courant, E.D.

    1977-01-01

    Plans are under way for the construction of a pair of intersecting storage rings providing for colliding beams of protons of energy at least 200 GeV. The rings (circumference 2.62 km) will contain superconducting magnets constructed with braided Nb--Ti filamentary wire, with a peak field of 4.0 T corresponding to an energy of 200 GeV. A current of 10 A of protons will be injected at 29 GeV from the existing AGS accelerator at Brookhaven, using the energy stacking technique similar to that employed at the CERN ISR; subsequently the stored beam will be accelerated gradually in the storage rings. Six intersection areas will be provided for experiments. They are designed to provide flexibility in beam characteristics for different experiments. The maximum luminosity at full energy is expected to be 1.0 x 10 33 cm -2 s -1 , at 29 GeV it will be approximately 10 32 cm -2 s -1 . Recent work with prototype magnets indicates that fields of 5.0 T can be produced. This has led to an alternative design of somewhat larger rings (circumference 3.77 km) that should be capable of providing colliding beams at 400 + 400 GeV

  8. 7 CFR 1033.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ....44(c) by the producer price differential as adjusted pursuant to § 1033.75; (2) An amount obtained by..., other solids, and butterfat prices, respectively; (3) The total value of the somatic cell adjustment to producer milk; and (4) An amount obtained by multiplying the pounds of skim milk and butterfat for which a...

  9. 7 CFR 1126.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ....44(c) by the producer price differential as adjusted pursuant to § 1126.75; (2) An amount obtained by..., other solids, and butterfat prices respectively; (3) The total value of the somatic cell adjustment to producer milk; and (4) An amount obtained by multiplying the pounds of skim milk and butterfat for which a...

  10. 7 CFR 1124.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ..., other solids, and butterfat prices respectively; and (3) An amount obtained by multiplying the pounds of skim milk and butterfat for which a value was computed pursuant to § 1124.60(h) by the producer price....44(c) by the producer price differential as adjusted pursuant to § 1124.75; (2) An amount obtained by...

  11. 7 CFR 1032.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ....44(c) by the producer price differential as adjusted pursuant to § 1032.75; (2) An amount obtained by..., other solids, and butterfat prices respectively; (3) The total value of the somatic cell adjustment to producer milk; and (4) An amount obtained by multiplying the pounds of skim milk and butterfat for which a...

  12. 7 CFR 1030.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ....44(c) by the producer price differential as adjusted pursuant to § 1030.75; (2) An amount obtained by..., other solids, and butterfat prices respectively; (3) The total value of the somatic cell adjustment to producer milk; and (4) An amount obtained by multiplying the pounds of skim milk and butterfat for which a...

  13. Ge nanobelts with high compressive strain fabricated by secondary oxidation of self-assembly SiGe rings

    DEFF Research Database (Denmark)

    Lu, Weifang; Li, Cheng; Lin, Guangyang

    2015-01-01

    Curled Ge nanobelts were fabricated by secondary oxidation of self-assembly SiGe rings, which were exfoliated from the SiGe stripes on the insulator. The Ge-rich SiGe stripes on insulator were formed by hololithography and modified Ge condensation processes of Si0.82Ge0.18 on SOI substrate. Ge...... nanobelts under a residual compressive strain of 2% were achieved, and the strain should be higher before partly releasing through bulge islands and breakage of the curled Ge nanobelts during the secondary oxidation process. The primary factor leading to compressive strain is thermal shrinkage of Ge...... nanobelts, which extrudes to Ge nanobelts in radial and tangent directions during the cooling process. This technique is promising for application in high-mobility Ge nano-scale transistors...

  14. The radiochemical purity of radiotracers as the criterion of their usefulness in investigations of hydrocarbons distillation

    International Nuclear Information System (INIS)

    Kolaczkowski, M.

    1976-01-01

    Among numerous analytic techniques of separation and analysis of radioactive products gas radiochromatography has proved to be particularly suitable. Organic bromides labelled with 82 Br-radionuclide are investigated. The analytic gas chromatographs equipped with appropriately constructed radiochromatographic attachments are used. The results of radiochemical purity determination of radiotracers are compared for various techniques. (author)

  15. Oxidation-resistant Ge-doped silicide coating on Cr-Cr2Nb alloys by pack cementation

    International Nuclear Information System (INIS)

    He Yirong

    1997-01-01

    The halide-activated pack cementation process was modified to produce a Ge-doped silicide diffusion coating on Cr-Cr 2 Nb alloys in a single processing step. The morphology and composition of the coating depended both on the pack composition and processing schedule and also on the composition and microstructure of the substrate. Higher Ge content in the pack suppressed the formation of CrSi 2 and reduced the growth kinetics of the coating. Ge was not homogeneously distributed in the coatings. Under cyclic and isothermal oxidation conditions, the Ge-doped silicide coating protected the Cr-Nb alloys from significant oxidation and from pesting by the formation of a Ge-doped silica film. (orig.)

  16. Signatures of triaxiality in low-spin spectra of 86Ge

    Science.gov (United States)

    Lettmann, M.; Werner, V.; Pietralla, N.; Doornenbal, P.; Obertelli, A.; Rodríguez, T. R.; Sieja, K.; Authelet, G.; Baba, H.; Calvet, D.; Château, F.; Chen, S.; Corsi, A.; Delbart, A.; Gheller, J.-M.; Giganon, A.; Gillibert, A.; Lapoux, V.; Motobayashi, T.; Niikura, M.; Paul, N.; Roussé, J.-Y.; Sakurai, H.; Santamaria, C.; Steppenbeck, D.; Taniuchi, R.; Uesaka, T.; Ando, T.; Arici, T.; Blazhev, A.; Browne, F.; Bruce, A.; Caroll, R. J.; Chung, L. X.; Cortés, M. L.; Dewald, M.; Ding, B.; Flavigny, F.; Franchoo, S.; Górska, M.; Gottardo, A.; Jungclaus, A.; Lee, J.; Linh, B. D.; Liu, J.; Liu, Z.; Lizarazo, C.; Momiyama, S.; Moschner, K.; Nagamine, S.; Nakatsuka, N.; Nita, C.; Nobs, C. R.; Olivier, L.; Patel, Z.; Podolyák, Zs.; Rudigier, M.; Saito, T.; Shand, C.; Söderström, P.-A.; Stefan, I.; Vaquero, V.; Wimmer, K.; Xu, Z.

    2018-05-01

    Low-spin states of neutron-rich 84,86,88Ge were measured by in-flight γ-ray spectroscopy at 270 MeV/u at the RIKEN-RIBF facility. The exotic beams have been produced by primary 238U in-flight fission reactions and impinged on the MINOS device. MINOS combines a 10-cm long LH2 target with a Time Projection Chamber (TPC) to reconstruct the reaction vertices. The reactions were selected by the BigRIPS and the ZeroDegree spectrometers for the incoming and outgoing channels, respectively. Emitted γ radiation was detected by the NaI-array DALI2. De-excitations from the {6}1+, {4}1,2+, and {2}1,2+ states of 84,86Ge and {4}1+ and {2}1,2+ states of 88Ge were observed. The data are compared to state-of-the-art shell model and beyond-mean-field calculations. Furthermore, a candidate for a {3}1+ state of 86Ge was identified. This state plays a key role in the discussion of ground-state triaxiality of 86Ge, along with other features of the low-energy level scheme. This work was published in [1].

  17. Production, characterization and operation of Ge enriched BEGe detectors in GERDA

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Andreotti, E.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Barros, N.; Baudis, L.; Bauer, C.; Becerici-Schmidt, N.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Budjáš, D.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Domula, A.; Egorov, V.; Falkenstein, R.; Freund, K.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gotti, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hegai, A.; Heisel, M.; Hemmer, S.; Heusser, G.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Ioannucci, L.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Klimenko, A.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Misiaszek, M.; Nemchenok, I.; Nisi, S.; O'Shaughnessy, C.; Palioselitis, D.; Pandola, L.; Pelczar, K.; Pessina, G.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salathe, M.; Schmitt, C.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Schönert, S.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Strecker, H.; Ur, C. A.; Vanhoefer, L.; Vasenko, A. A.; von Sturm, K.; Wagner, V.; Walter, M.; Wegmann, A.; Wester, T.; Wilsenach, H.; Wojcik, M.; Yanovich, E.; Zavarise, P.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2015-02-01

    The GERmanium Detector Array ( Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay () of Ge. Germanium detectors made of material with an enriched Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present paper reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. The detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.

  18. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Shenoy, K.T.; Sreenivas, T.

    2015-01-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40–60 MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. - Highlights: • Radiotracer technique was applied for evaluation of design of a pilot-scale continuous leaching reactor. • Mean residence time and dead volume were estimated. Dead volume was found to be ranging from 4% to 15% at different operating conditions. • Tank-in-series model was used to simulate the measured RTD data and was found suitable to describe the flow in the reactor. • No flow abnormality was found and the reactor behaved as a well-mixed system. The design of the reactor was validated

  19. Growth and characterization of isotopically enriched 70Ge and 74Ge single crystals

    International Nuclear Information System (INIS)

    Itoh, K.

    1992-10-01

    Isotopically enriched 70 Ge and 74 Ge single crystals were successfully gown by a newly developed vertical Bridgman method. The system allows us to reliably grow high purity Ge single crystals of approximately 1 cm 3 volume. To our knowledge, we have grown the first 70 Ge single crystal. The electrically active chemical impurity concentration for both crystals was found to be ∼2 x cm -3 which is two order of magnitude better that of 74 Ge crystals previously grown by two different groups. Isotopic enrichment of the 70 Ge and the 74 Ge crystals is 96.3% and 96.8%, respectively. The residual chemical impurities present in both crystals were identified as phosphorus, copper, aluminum, and indium. A wide variety of experiments which take advantage of the isotopic purity of our crystals are discussed

  20. Imaging of Non-Prostate Cancers Using PSMA-Targeted Radiotracers: Rationale, Current State of the Field, and a Call to Arms.

    Science.gov (United States)

    Salas Fragomeni, Roberto A; Amir, Tali; Sheikhbahaei, Sara; Harvey, Susan C; Javadi, Mehrbod S; Solnes, Lilja; Kiess, Ana; Allaf, Mohamad E; Pomper, Martin; Gorin, Michael A; Rowe, Steven P

    2018-03-15

    Prostate-specific membrane antigen (PSMA) is a type II transmembrane glycoprotein that is highly overexpressed on prostate cancer epithelial cells and for which there is a growing body of literature examining the role of small molecule and antibody radiotracers targeted against this protein for prostate cancer detection and therapy. Despite its name, PSMA is also expressed, to varying degrees, in the neovasculature of a wide variety of non-prostate cancers; indeed, the pathology literature is replete with promising immunohistochemistry findings. A number of groups have begun to correlate those pathology-level results with in vivo imaging and therapy in non-prostate cancers using the same PSMA-targeted agents that have been so successful in prostate cancer. The potential to leverage radiotracers targeted to PSMA beyond prostate cancer is a promising approach for many cancers, and PSMA-targeted agents may be able to supplement or fill gaps left by other agents. However, to date, the majority of the reported findings with PSMA-targeted radiotracers in non-prostate malignancies has been in case reports and small case series, and the field must adopt a more thorough approach to the design and execution of larger prospective trials in order to realize the potential of these promising agents outside of prostate cancer. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. Search for Charged Higgs Bosons in $e^{+} e^{-}$ Collisions at $\\sqrt{s}$=189-202 GeV

    CERN Document Server

    Abdallah, J.; Adam, W.; Adye, T.; Adzic, P.; Albrecht, Z.; Alderweireld, T.; Alekseev, G.D.; Alemany, R.; Allmendinger, T.; Allport, P.P.; Almehed, S.; Amaldi, U.; Amapane, N.; Amato, S.; Anashkin, E.; Anassontzis, E.G.; Andersson, P.; Andreazza, A.; Andringa, S.; Anjos, N.; Antilogus, P.; Apel, W.D.; Arnoud, Y.; Asman, B.; Augustin, J.E.; Augustinus, A.; Baillon, P.; Ballestrero, A.; Bambade, P.; Barao, F.; Barbiellini, G.; Barbier, R.; Bardin, D.Yu.; Barker, G.J.; Baroncelli, A.; Battaglia, M.; Baubillier, M.; Becks, K.H.; Begalli, M.; Behrmann, A.; Bellunato, T.; Belokopytov, Yu.; Belous, K.; Benekos, N.C.; Benvenuti, A.C.; Berat, C.; Berggren, M.; Berntzon, L.; Bertrand, D.; Besancon, M.; Besson, N.; Bilenky, Mikhail S.; Bloch, D.; Blom, H.M.; Bol, L.; Bonesini, M.; Boonekamp, M.; Booth, P.S.L.; Borisov, G.; Bosio, C.; Botner, O.; Boudinov, E.; Bouquet, B.; Bowcock, T.J.V.; Boyko, I.; Bozovic, I.; Bozzo, M.; Bracko, M.; Branchini, P.; Brenner, R.A.; Brodet, E.; Bruckman, P.; Brunet, J.M.; Bugge, L.; Buschmann, P.; Caccia, M.; Calvi, M.; Camporesi, T.; Canale, V.; Carena, F.; Carroll, L.; Caso, C.; Castillo Gimenez, M.V.; Cattai, A.; Cavallo, F.R.; Chapkin, M.; Charpentier, P.; Checchia, P.; Chelkov, G.A.; Chierici, R.; Shlyapnikov, P.; Chochula, P.; Chorowicz, V.; Chudoba, J.; Cieslik, K.; Collins, P.; Contri, R.; Cortina, E.; Cosme, G.; Cossutti, F.; Costa, M.; Crawley, H.B.; Crennell, D.; Croix, J.; Cuevas Maestro, J.; Czellar, S.; D'Hondt, J.; Dalmau, J.; Davenport, M.; Da Silva, W.; Della Ricca, G.; Delpierre, P.; Demaria, N.; De Angelis, A.; De Boer, W.; De Clercq, C.; De Lotto, B.; De Min, A.; De Paula, L.; Dijkstra, H.; Di Ciaccio, L.; Doroba, K.; Dracos, M.; Drees, J.; Dris, M.; Eigen, G.; Ekelof, T.; Ellert, M.; Elsing, M.; Engel, J.P.; Espirito Santo, M.C.; Fanourakis, G.; Fassouliotis, D.; Feindt, M.; Fernandez, J.; Ferrer, A.; Ferrer-Ribas, E.; Ferro, F.; Firestone, A.; Flagmeyer, U.; Foeth, H.; Fokitis, E.; Fontanelli, F.; Franek, B.; Frodesen, A.G.; Fruhwirth, R.; Fulda-Quenzer, F.; Fuster, J.; Gamba, D.; Gamblin, S.; Gandelman, M.; Garcia, C.; Gaspar, C.; Gaspar, M.; Gasparini, U.; Gavillet, P.; Gazis, Evangelos; Gele, D.; Geralis, T.; Ghodbane, N.; Gil Botella, Ines; Glege, F.; Gokieli, R.; Golob, B.; Gomez-Ceballos, G.; Goncalves, P.; Gonzalez Caballero, I.; Gopal, G.; Gorn, L.; Guz, Yu.; Gracco, V.; Grahl, J.; Graziani, E.; Grosdidier, G.; Grzelak, K.; Guy, J.; Haag, C.; Hahn, F.; Hahn, S.; Haider, S.; Hallgren, A.; Hamacher, K.; Hamilton, K.; Hansen, J.; Harris, F.J.; Haug, S.; Hauler, F.; Hedberg, V.; Heising, S.; Hernandez, J.J.; Herquet, P.; Herr, H.; Hertz, O.; Higon, E.; Holmgren, S.O.; Holt, P.J.; Hoorelbeke, S.; Houlden, M.; Hrubec, J.; Hughes, G.J.; Hultqvist, K.; Jackson, John Neil; Jacobsson, R.; Jalocha, P.; Jarlskog, C.; Jarlskog, G.; Jarry, P.; Jean-Marie, B.; Jeans, D.; Johansson, Erik Karl; Jonsson, P.; Joram, C.; Juillot, P.; Jungermann, L.; Kapusta, Frederic; Karafasoulis, K.; Katsanevas, S.; Katsoufis, E.C.; Keranen, R.; Kernel, G.; Kersevan, B.P.; Khokhlov, Yu.A.; Khomenko, B.A.; Khovansky, N.N.; Kiiskinen, A.; King, B.; Kinvig, A.; Kjaer, N.J.; Klapp, O.; Kluit, P.; Kokkinias, P.; Kostyukhin, V.; Kourkoumelis, C.; Kuznetsov, O.; Krammer, M.; Kriznic, E.; Krumshtein, Z.; Kubinec, P.; Kucharczyk, M.; Kurowska, J.; Lamsa, J.W.; Laugier, J.P.; Leder, G.; Ledroit, Fabienne; Leinonen, L.; Leisos, A.; Leitner, R.; Lemonne, J.; Lenzen, G.; Lepeltier, V.; Lesiak, T.; Lethuillier, M.; Libby, J.; Liebig, W.; Liko, D.; Lipniacka, A.; Lippi, I.; Loken, J.G.; Lopes, J.H.; Lopez, J.M.; Lopez-Fernandez, R.; Loukas, D.; Lutz, P.; Lyons, L.; MacNaughton, J.; Mahon, J.R.; Maio, A.; Malek, A.; Maltezos, S.; Malychev, V.; Mandl, F.; Marco, J.; Marco, R.; Marechal, B.; Margoni, M.; Marin, J.C.; Mariotti, C.; Markou, A.; Martinez-Rivero, C.; Marti i Garcia, S.; Masik, J.; Mastroyiannopoulos, N.; Matorras, F.; Matteuzzi, C.; Matthiae, G.; Mazzucato, F.; Mazzucato, M.; McCubbin, M.; McKay, R.; McNulty, R.; Merle, E.; Meroni, C.; Meyer, W.T.; Myagkov, A.; Migliore, E.; Mirabito, L.; Mitaroff, W.A.; Mjornmark, U.; Moa, T.; Moch, M.; Monig, Klaus; Monge, M.R.; Montenegro, J.; Moraes, D.; Morettini, P.; Morton, G.; Muller, U.; Munich, K.; Mulders, M.; Mundim, L.M.; Murray, W.J.; Muryn, B.; Myatt, G.; Myklebust, T.; Nassiakou, M.; Navarria, F.L.; Nawrocki, K.; Negri, P.; Nemecek, S.; Neufeld, N.; Nicolaidou, R.; Niezurawski, P.; Nikolenko, M.; Nomokonov, V.; Nygren, A.; Obraztsov, V.; Olshevsky, A.G.; Onofre, A.; Orava, R.; Osterberg, K.; Ouraou, A.; Oyanguren, A.; Paganoni, M.; Paiano, S.; Pain, R.; Paiva, R.; Palacios, J.; Palka, H.; Papadopoulou, T.D.; Pape, L.; Parkes, C.; Parodi, F.; Parzefall, U.; Passeri, A.; Passon, O.; Peralta, L.; Perepelitsa, V.; Pernicka, M.; Perrotta, A.; Petridou, C.; Petrolini, A.; Phillips, H.T.; Pierre, F.; Pimenta, M.; Piotto, E.; Podobnik, T.; Poireau, V.; Pol, M.E.; Polok, G.; Poropat, P.; Pozdnyakov, V.; Privitera, P.; Pukhaeva, N.; Pullia, A.; Radojicic, D.; Ragazzi, S.; Rahmani, H.; Ratoff, P.N.; Read, Alexander L.; Rebecchi, P.; Redaelli, Nicola Giuseppe; Regler, M.; Rehn, J.; Reid, D.; Reinhardt, R.; Renton, P.B.; Resvanis, L.K.; Richard, F.; Ridky, J.; Rinaudo, G.; Ripp-Baudot, Isabelle; Romero, A.; Ronchese, P.; Rosenberg, E.I.; Rosinsky, P.; Rovelli, T.; Ruhlmann-Kleider, V.; Ruiz, A.; Saarikko, H.; Sacquin, Y.; Sadovsky, A.; Sajot, G.; Salmi, L.; Salt, J.; Sampsonidis, D.; Sannino, M.; Savoy-Navarro, A.; Schwanda, C.; Schwemling, P.; Schwering, B.; Schwickerath, U.; Scuri, Fabrizio; Seager, P.; Sedykh, Yu.; Segar, A.M.; Sekulin, R.; Sette, G.; Shellard, R.C.; Siebel, M.; Simard, L.; Simonetto, F.; Sisakian, A.N.; Smadja, G.; Smirnova, O.; Smith, G.R.; Sokolov, A.; Solovianov, O.; Sopczak, A.; Sosnowski, R.; Spassoff, T.; Spiriti, E.; Squarcia, S.; Stanescu, C.; Stanitzki, M.; Stocchi, A.; Strauss, J.; Strub, R.; Stugu, B.; Szczekowski, M.; Szeptycka, M.; Tabarelli, T.; Taffard, A.; Tegenfeldt, F.; Terranova, F.; Timmermans, Jan; Tinti, N.; Tkachev, L.G.; Tobin, M.; Todorova, S.; Tome, B.; Tonazzo, A.; Tortora, L.; Tortosa, P.; Treille, D.; Tristram, G.; Trochimczuk, M.; Troncon, C.; Turluer, M.L.; Tyapkin, I.A.; Tyapkin, P.; Tzamarias, S.; Ullaland, O.; Uvarov, V.; Valenti, G.; Vallazza, E.; Vander Velde, C.; Van Dam, Piet; Van Den Boeck, W.; Van Doninck, Walter; Van Eldik, J.; Van Lysebetten, A.; Van Remortel, N.; Van Vulpen, I.; Vegni, G.; Ventura, L.; Venus, W.; Verbeure, F.; Verdier, P.; Verlato, M.; Vertogradov, L.S.; Verzi, V.; Vilanova, D.; Vitale, L.; Vlasov, E.; Vodopianov, A.S.; Voulgaris, G.; Vrba, V.; Wahlen, H.; Washbrook, A.J.; Weiser, C.; Wicke, D.; Wickens, J.H.; Wilkinson, G.R.; Winter, M.; Witek, M.; Wolf, G.; Yi, J.; Yushchenko, O.; Zalewska, A.; Zalewski, P.; Zavrtanik, D.; Zevgolatakos, E.; Zimine, N.I.; Zinchenko, A.; Zoller, P.; Zumerle, G.; Zupan, M.

    2002-01-01

    A search for pair-produced charged Higgs bosons was performed in the high energy data collected by the DELPHI detector at LEP II at centre-of-mass energies from 189~GeV to 202~GeV\\@. The three different final states, $\\tau \

  2. Study of the pπ- system produced in reaction K+n→K+π-p at 8.25GeV/c and comparison with data at 4.6 and 12GeV/c

    International Nuclear Information System (INIS)

    Vignaud, D.; Ginestet, J.; Burlaud, D.; Sene, M.

    1975-01-01

    The fragmentation of the neutron into pπ - induced by incident K + of 8.25GeV/c is studied using data from the CERN 2m deuterium bubble chamber and compared with data at 4.6 and 12GeV/c. The pπ - low mass enhancement below 1.85GeV/c is analyzed and the major part exhibits the properties expected for diffraction dissociation. The presence of resonances is discussed. The data are fairly well represented by a double Regge exchange model involving pion and Pomeron exchanges. The violation of the s-channel and t-channel helicity conservation is observed and compared to the s-channel description of Humble [fr

  3. Inspecting the microstructure of electrically active defects at the Ge/GeOx interface

    Science.gov (United States)

    Fanciulli, Marco; Baldovino, Silvia; Molle, Alessandro

    2012-02-01

    High mobility substrates are important key elements in the development of advanced devices targeting a vast range of functionalities. Among them, Ge showed promising properties promoting it as valid candidate to replace Si in CMOS technology. However, the electrical quality of the Ge/oxide interface is still a problematic issue, in particular for the observed inversion of the n-type Ge surface, attributed to the presence of dangling bonds inducing a severe band bending [1]. In this scenario, the identification of electrically active defects present at the Ge/oxide interface and the capability to passivate or anneal them becomes a mandatory issue aiming at an electrically optimized interface. We report on the application of highly sensitive electrically detected magnetic resonance (EDMR) techniques in the investigation of defects at the interface between Ge and GeO2 (or GeOx), including Ge dangling bonds and defects in the oxide [2]. In particular we will investigate how different surface orientations, e.g. the (001) against the (111) Ge surface, impacts the microstructure of the interface defects. [1] P. Tsipas and A. Dimoulas, Appl. Phys. Lett. 94, 012114 (2009) [2] S. Baldovino, A. Molle, and M. Fanciulli, Appl. Phys. Lett. 96, 222110 (2010)

  4. 71Ga and 73Ga levels as observed in the (t,p) reaction

    International Nuclear Information System (INIS)

    Vergnes, M.N.; Rotbard, G.; Guilbaut, F.; Ardouin, D.; Lebrun, C.

    1978-01-01

    A study of the (t,p) reaction on the two stable Ga isotopes has been performed. The reaction protons were analyzed in a Q3D spectrometer with a resulting energy resolution approximately 18 keV. Levels up to about 3 MeV excitation energy in 71 Ga and 2.75 MeV in 73 Ga were measured with 11 new levels observed in the first case and 18 in the second. The angular distributions have been compared to pure distributions observed in the 72 Ge(t,p) and 74 Ge(t,p) reactions at the same energy and found to correspond mostly to pure angular momentum (L) transfer although mixing of L's is allowed. A number of new spins assignments are made for Ga levels and the results are used to discuss the spin of 73 Znsub(g.s.). The striking splitting of the L=0 strength in three approximately equal components, observed in 73 Ga, strongly supports a transition in nuclear deformation between N=40 and 42

  5. Particles produced in association with PSI(3098)

    International Nuclear Information System (INIS)

    Alverson, G.O.

    1979-01-01

    Dimuon production was studied at 217 GeV/c in π - -hydrogen and π - -beryllium collisions with a multiparticle spectrometer to detect associated particles. Particular attention was paid to the phiγ spectrum which shows an excess of events in the region 3.5 GeV. Attributing this to the presence of the chi(approx. 3.5) states implies that 94 +- 50% of psis are produced via radiative chi decay

  6. Radiotracer investigation to study residence time distribution in an evaporator system

    Energy Technology Data Exchange (ETDEWEB)

    Pant, H J; Yelgaonkar, V N; Navada, S V [Isotope Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    Determination of mean residence time, residence time distribution and evaluation of flow behavior in industrial process systems is of prime importance in order to control the process and to evaluate the performance of the process systems. This paper describes a case study carried out in an evaporator system in a sugar factory near Pune for determination of the mean residence time and residence time distribution using radiotracer technique. The mean residence time (MRT) was determined to be 4 seconds. The mathematical modelling of residence time distribution (RTD) data indicated the flow behaviour of the system to be a well mixed type. (author). 5 refs., 2 figs., 1 tab.

  7. Distribution and Substitution Mechanism of Ge in a Ge-(Fe-Bearing Sphalerite

    Directory of Open Access Journals (Sweden)

    Nigel J. Cook

    2015-03-01

    Full Text Available The distribution and substitution mechanism of Ge in the Ge-rich sphalerite from the Tres Marias Zn deposit, Mexico, was studied using a combination of techniques at μm- to atomic scales. Trace element mapping by Laser Ablation Inductively Coupled Mass Spectrometry shows that Ge is enriched in the same bands as Fe, and that Ge-rich sphalerite also contains measurable levels of several other minor elements, including As, Pb and Tl. Micron- to nanoscale heterogeneity in the sample, both textural and compositional, is revealed by investigation using Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM combined with Synchrotron X-ray Fluorescence mapping and High-Resolution Transmission Electron Microscopy imaging of FIB-prepared samples. Results show that Ge is preferentially incorporated within Fe-rich sphalerite with textural complexity finer than that of the microbeam used for the X-ray Absorption Near Edge Structure (XANES measurements. Such heterogeneity, expressed as intergrowths between 3C sphalerite and 2H wurtzite on  zones, could be the result of either a primary growth process, or alternatively, polystage crystallization, in which early Fe-Ge-rich sphalerite is partially replaced by Fe-Ge-poor wurtzite. FIB-SEM imaging shows evidence for replacement supporting the latter. Transformation of sphalerite into wurtzite is promoted by (111* twinning or lattice-scale defects, leading to a heterogeneous ZnS sample, in which the dominant component, sphalerite, can host up to ~20% wurtzite. Ge K-edge XANES spectra for this sphalerite are identical to those of the germanite and argyrodite standards and the synthetic chalcogenide glasses GeS2 and GeSe2, indicating the Ge formally exists in the tetravalent form in this sphalerite. Fe K-edge XANES spectra for the same sample indicate that Fe is present mainly as Fe2+, and Cu K-edge XANES spectra are characteristic for Cu+. Since there is no evidence for coupled substitution involving a monovalent

  8. Therapeutic and prevention strategies against human enterovirus 71 infection

    Science.gov (United States)

    Kok, Chee Choy

    2015-01-01

    Human enterovirus 71 (HEV71) is the cause of hand, foot and mouth disease and associated neurological complications in children under five years of age. There has been an increase in HEV71 epidemic activity throughout the Asia-Pacific region in the past decade, and it is predicted to replace poliovirus as the extant neurotropic enterovirus of highest global public health significance. To date there is no effective antiviral treatment and no vaccine is available to prevent HEV71 infection. The increase in prevalence, virulence and geographic spread of HEV71 infection over the past decade provides increasing incentive for the development of new therapeutic and prevention strategies against this emerging viral infection. The current review focuses on the potential, advantages and disadvantages of these strategies. Since the explosion of outbreaks leading to large epidemics in China, research in natural therapeutic products has identified several groups of compounds with anti-HEV71 activities. Concurrently, the search for effective synthetic antivirals has produced promising results. Other therapeutic strategies including immunotherapy and the use of oligonucleotides have also been explored. A sound prevention strategy is crucial in order to control the spread of HEV71. To this end the ultimate goal is the rapid development, regulatory approval and widespread implementation of a safe and effective vaccine. The various forms of HEV71 vaccine designs are highlighted in this review. Given the rapid progress of research in this area, eradication of the virus is likely to be achieved. PMID:25964873

  9. Biodistribution of gyroxin using 125I as radiotracer

    International Nuclear Information System (INIS)

    Alves da Silva, J.A.; Ribela, M.T.C.P.; Rogero, J.R.; Camillo, M.A.P.; Muramoto, E.

    2006-01-01

    The use of radiotracers in the research of animal venom has been scarce, although it allows an excellent approach to follow the process of bioavailability, biodistribution and kinetics of toxins. The purpose of this study was to assess gyroxin action mechanism, transport, compartments and action sites. This toxin is a thrombin-like and causes the barrel rotation syndrome. The gyroxin was labeled with 125 I and used as a tracer for the in vivo assay in mice. Blood samples and organs were collected at different time intervals, weighed and analyzed in a gamma-counter. The data was related with tissues distribution of protease activated receptor (PAR). Biodistribution assay allowed dividing the organs into three groups. The first one with the organs that followed the blood kinetics, the second with the organs related to metabolisms and elimination, and the third with the organs in which the gyroxin concentration increased during the observation period. (author)

  10. Design of laboratory radiotracer studies in marine radioecology

    International Nuclear Information System (INIS)

    Schulte, E.H.

    1997-01-01

    A condensed description of methods used in laboratory radiotracer studies in marine radioecology is presented showing also the difficulties which may be encountered in order to obtain realistic and comparable information on the general behaviour of radionuclides in marine organisms. Practical guidance on the choice of the biological material and how to setup laboratory experiments and to control properly important experimental conditions are given. Key parameters like concentration factors and biological half-lives are defined and the theoretical estimation and practical determination of input, uptake, accumulation and loss of radionuclides in marine biota are formulated by the aid of mathematical equations. Examples of uptake and loss curves obtained in the laboratory are shown. The importance of some environmental factors (temperature, food, growth) on uptake and loss of radionuclides are demonstrated. Comparison of experimental and field data of concentration factors is reported to show the difficulty in extrapolating from laboratory experiments to nature. (author)

  11. Si, Ge and SiGe wires for sensor application

    International Nuclear Information System (INIS)

    Druzhinin, A.A.; Khoverko, Yu.M.; Ostrovskii, I.P.; Nichkalo, S.I.; Nikolaeva, A.A.; Konopko, L.A.; Stich, I.

    2011-01-01

    Resistance and magnetoresistance of Si, Ge and Si-Ge micro- and nanowires were studied in temperature range 4,2-300 K at magnetic fields up to 14 T. The wires diameters range from 200 nm to 20 μm. Ga-In gates were created to wires and ohmic I-U characteristics were observed in all temperature range. It was found high elastic strain for Ge nanowires (of about 0,7%) as well as high magnitude of magnetoresistance (of about 250% at 14 T), which was used to design multifunctional sensor of simultaneous measurements of strain and magnetic field intensity. (authors)

  12. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique.

    Science.gov (United States)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J; Biswal, Jayashree; Sharma, Vijay K; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K; Rao, S Madhukar; Dash, A

    2016-05-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Multi-photon production in $e^{+}e^{-}$ collisions at $\\sqrt{s}$ = 189 GeV

    CERN Document Server

    Abbiendi, G.; Alexander, G.; Allison, John; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bellerive, A.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bloodworth, I.J.; Bock, P.; Bohme, J.; Boeriu, O.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brigliadori, L.; Brown, Robert M.; Burckhart, H.J.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couchman, J.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Dallison, S.; Davis, R.; De Jong, S.; de Roeck, A.; Dervan, P.; Desch, K.; Dienes, B.; Dixit, M.S.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Estabrooks, P.G.; Etzion, E.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Feld, L.; Ferrari, P.; Fiedler, F.; Fierro, M.; Fleck, I.; Frey, A.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Graham, K.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hajdu, C.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Harder, K.; Harel, A.; Hargrove, C.K.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hobson, P.R.; Hocker, James Andrew; Hoffman, Kara Dion; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klier, A.; Kobayashi, T.; Kobel, M.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kyberd, P.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lauber, J.; Lawson, I.; Layter, J.G.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; Lillich, J.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Lu, J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mader, W.; Mannelli, M.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Merritt, F.S.; Mes, H.; Meyer, I.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Quadt, A.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Rosati, S.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schmitt, S.; Schoning, A.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Spagnolo, S.; Sproston, M.; Stahl, A.; Stephens, K.; Stoll, K.; Strom, David M.; Strohmer, R.; Surrow, B.; Talbot, S.D.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomas, J.; Thomson, M.A.; Torrence, E.; Towers, S.; Trefzger, T.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Voss, H.; Wackerle, F.; Wagner, A.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; Wetterling, D.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Zacek, V.; Zer-Zion, D.

    1999-01-01

    The process e+e- to 2 (or 3) gammas is studied using data recorded with the OPAL detector at LEP. The data sample taken at a centre-of-mass energy of 189 GeV corresponds to a total integrated luminosity of 178 pb-1. The measured cross-section agrees well with the expectation from QED. A fit to the angular distribution is used to obtain improved limits at 95% CL on the QED cut-off parameters: Lambda+ > 304 GeV and Lambda- > 295 GeV as well as a mass limit for an excited electron, Me* > 306 GeV assuming equal e*egamma and eegamma couplings. Graviton exchange in the context of theories with higher dimensions is excluded for scales G+ < 660 GeV and G- < 634 GeV. No evidence for resonance production is found in the invariant mass spectrum of photon pairs. Limits are obtained for the cross-section times branching ratio for a resonance decaying into two photons and produced in association with another photon.

  14. Gate-stack engineering for self-organized Ge-dot/SiO2/SiGe-shell MOS capacitors

    Directory of Open Access Journals (Sweden)

    Wei-Ting eLai

    2016-02-01

    Full Text Available We report the first-of-its-kind, self-organized gate-stack heterostructure of Ge-dot/SiO2/SiGe-shell on Si fabricated in a single step through the selective oxidation of a SiGe nano-patterned pillar over a Si3N4 buffer layer on a Si substrate. Process-controlled tunability of the Ge-dot size (7.5−90 nm, the SiO2 thickness (3−4 nm, and as well the SiGe-shell thickness (2−15 nm has been demonstrated, enabling a practically-achievable core building block for Ge-based metal-oxide-semiconductor (MOS devices. Detailed morphologies, structural, and electrical interfacial properties of the SiO2/Ge-dot and SiO2/SiGe interfaces were assessed using transmission electron microscopy, energy dispersive x-ray spectroscopy, and temperature-dependent high/low-frequency capacitance-voltage measurements. Notably, NiGe/SiO2/SiGe and Al/SiO2/Ge-dot/SiO2/SiGe MOS capacitors exhibit low interface trap densities of as low as 3-5x10^11 cm^-2·eV^-1 and fixed charge densities of 1-5x10^11 cm^-2, suggesting good-quality SiO2/SiGe-shell and SiO2/Ge-dot interfaces. In addition, the advantage of having single-crystalline Si1-xGex shell (x > 0.5 in a compressive stress state in our self-aligned gate-stack heterostructure has great promise for possible SiGe (or Ge MOS nanoelectronic and nanophotonic applications.

  15. A simple and efficient in vitro method for metabolism studies of radiotracers

    International Nuclear Information System (INIS)

    Lee, Sang-Yoon; Choe, Yearn Seong; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo; Kim, Byung-Tae

    2001-01-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[ 18 F]fluoromethylbenzyl- ([ 18 F]1) and 4-[ 18 F]fluorobenzyl-piperidine moieties ([ 18 F]2) was studied and compared with the in vivo metabolism. Defluorination of the [ 18 F]1 mainly occurred to generate [ 18 F]fluoride ion both in vitro and in vivo. In contrast, the [ 18 F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[ 18 F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers

  16. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1992--July 15, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1995-07-17

    This research continues the long term goals of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. This program fits into the nuclear medicine component of DOE`s mission, which is aimed at enhancing the beneficial applications of radiation, radionuclides, and stable isotopes in the diagnosis, study and treatment of human diseases. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology/Immunology; and Imaging Physics. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Section under the DOE grant during the 1992--1995 will be employed in the Pharmacology/Immunology component in the period 1996--1999. Imaging Physics resolves relevant imaging related physics issues that arise during the experimentation that results. In addition to the basic research mission, this project also provides a basis for training of research scientists in radiochemistry, immunology, bioengineering and imaging physics.

  17. Improving cancer treatment with cyclotron produced radionuclides. Comprehensive progress report, February 1, 1992--July 15, 1995

    International Nuclear Information System (INIS)

    Larson, S.M.; Finn, R.D.

    1995-01-01

    This research continues the long term goals of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. This program fits into the nuclear medicine component of DOE's mission, which is aimed at enhancing the beneficial applications of radiation, radionuclides, and stable isotopes in the diagnosis, study and treatment of human diseases. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology/Immunology; and Imaging Physics. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Section under the DOE grant during the 1992--1995 will be employed in the Pharmacology/Immunology component in the period 1996--1999. Imaging Physics resolves relevant imaging related physics issues that arise during the experimentation that results. In addition to the basic research mission, this project also provides a basis for training of research scientists in radiochemistry, immunology, bioengineering and imaging physics

  18. GeV GAMMA-RAY FLUX UPPER LIMITS FROM CLUSTERS OF GALAXIES

    International Nuclear Information System (INIS)

    Ackermann, M.; Ajello, M.; Allafort, A.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Borgland, A. W.; Bouvier, A.; Buehler, R.; Baldini, L.; Bellazzini, R.; Bregeon, J.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Blasi, P.; Bonamente, E.; Brandt, T. J.; Brigida, M.; Bruel, P.

    2010-01-01

    The detection of diffuse radio emission associated with clusters of galaxies indicates populations of relativistic leptons infusing the intracluster medium (ICM). Those electrons and positrons are either injected into and accelerated directly in the ICM, or produced as secondary pairs by cosmic-ray ions scattering on ambient protons. Radiation mechanisms involving the energetic leptons together with the decay of neutral pions produced by hadronic interactions have the potential to produce abundant GeV photons. Here, we report on the search for GeV emission from clusters of galaxies using data collected by the Large Area Telescope on the Fermi Gamma-ray Space Telescope from 2008 August to 2010 February. Thirty-three galaxy clusters have been selected according to their proximity and high mass, X-ray flux and temperature, and indications of non-thermal activity for this study. We report upper limits on the photon flux in the range 0.2-100 GeV toward a sample of observed clusters (typical values (1-5) x10 -9 photon cm -2 s -1 ) considering both point-like and spatially resolved models for the high-energy emission and discuss how these results constrain the characteristics of energetic leptons and hadrons, and magnetic fields in the ICM. The volume-averaged relativistic-hadron-to-thermal energy density ratio is found to be <5%-10% in several clusters.

  19. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  20. Shell morphology and Raman spectra of epitaxial Ge-SixGe1-x and Si-SixGe1-x core-shell nanowires

    Science.gov (United States)

    Wen, Feng; Dillen, David C.; Kim, Kyounghwan; Tutuc, Emanuel

    2017-06-01

    We investigate the shell morphology and Raman spectra of epitaxial Ge-SixGe1-x and Si-SixGe1-x core-shell nanowire heterostructures grown using a combination of a vapor-liquid-solid (VLS) growth mechanism for the core, followed by in-situ epitaxial shell growth using ultra-high vacuum chemical vapor deposition. Cross-sectional transmission electron microscopy reveals that the VLS growth yields cylindrical Ge, and Si nanowire cores grown along the ⟨111⟩, and ⟨110⟩ or ⟨112⟩ directions, respectively. A hexagonal cross-sectional morphology is observed for Ge-SixGe1-x core-shell nanowires terminated by six {112} facets. Two distinct morphologies are observed for Si-SixGe1-x core-shell nanowires that are either terminated by four {111} and two {100} planes associated with the ⟨110⟩ growth direction or four {113} and two {111} planes associated with the ⟨112⟩ growth direction. We show that the Raman spectra of Si- SixGe1-x are correlated with the shell morphology thanks to epitaxial growth-induced strain, with the core Si-Si mode showing a larger red shift in ⟨112⟩ core-shell nanowires compared to their ⟨110⟩ counterparts. We compare the Si-Si Raman mode value with calculations based on a continuum elasticity model coupled with the lattice dynamic theory.

  1. Room Temperature Electroluminescence from Tensile-Strained Si0.13Ge0.87/Ge Multiple Quantum Wells on a Ge Virtual Substrate

    Directory of Open Access Journals (Sweden)

    Guangyang Lin

    2016-09-01

    Full Text Available Direct band electroluminescence (EL from tensile-strained Si0.13Ge0.87/Ge multiple quantum wells (MQWs on a Ge virtual substrate (VS at room temperature is reported herein. Due to the competitive result of quantum confinement Stark effect and bandgap narrowing induced by tensile strain in Ge wells, electroluminescence from Γ1-HH1 transition in 12-nm Ge wells was observed at around 1550 nm. As injection current density increases, additional emission shoulders from Γ2-HH2 transition in Ge wells and Ge VS appeared at around 1300–1400 nm and 1600–1700 nm, respectively. The peak energy of EL shifted to the lower energy side superquadratically with an increase of injection current density as a result of the Joule heating effect. During the elevation of environmental temperature, EL intensity increased due to a reduction of energy between L and Γ valleys of Ge. Empirical fitting of the relationship between the integrated intensity of EL (L and injection current density (J with L~Jm shows that the m factor increased with injection current density, suggesting higher light emitting efficiency of the diode at larger injection current densities, which can be attributed to larger carrier occupations in the Γ valley and the heavy hole (HH valance band at higher temperatures.

  2. Effects of C+ ion implantation on electrical properties of NiSiGe/SiGe contacts

    International Nuclear Information System (INIS)

    Zhang, B.; Yu, W.; Zhao, Q.T.; Buca, D.; Breuer, U.; Hartmann, J.-M.; Holländer, B.; Mantl, S.; Zhang, M.; Wang, X.

    2013-01-01

    We have investigated the morphology and electrical properties of NiSiGe/SiGe contact by C + ions pre-implanted into relaxed Si 0.8 Ge 0.2 layers. Cross-section transmission electron microscopy revealed that both the surface and interface of NiSiGe were improved by C + ions implantation. In addition, the effective hole Schottky barrier heights (Φ Bp ) of NiSiGe/SiGe were extracted. Φ Bp was observed to decrease substantially with an increase in C + ion implantation dose

  3. Identification and production of mouse scFv to specific epitope of enterovirus-71 virion protein-2 (VP2).

    Science.gov (United States)

    Thanongsaksrikul, Jeeraphong; Srimanote, Potjanee; Tongtawe, Pongsri; Glab-Ampai, Kittirat; Malik, Aijaz Ahmad; Supasorn, Oratai; Chiawwit, Phatcharaporn; Poovorawan, Yong; Chaicumpa, Wanpen

    2018-05-01

    Enterovirus-71 (EV71) and coxsackievirus-A16 (CA16) frequently cause hand-foot-mouth disease (HFMD) epidemics among infants and young children. CA16 infections are usually mild, while EV71 disease may be fatal due to neurologic complications. As such, the ability to rapidly and specifically recognize EV71 is needed to facilitate proper case management and epidemic control. Accordingly, the aim of this study was to generate antibodies to EV71-virion protein-2 (VP2) by phage display technology for further use in specific detection of EV71. A recombinant peptide sequence of EV71-VP2, carrying a predicted conserved B cell epitope fused to glutathione-S-transferase (GST) (designated GST-EV71-VP2/131-160), was produced. The fusion protein was used as bait in in-solution biopanning to separate protein-bound phages from a murine scFv (MuscFv) phage display library constructed from an immunoglobulin gene repertoire from naïve ICR mice. Three phage-transformed E. coli clones (clones 63, 82, and 83) produced MuscFvs that bound to the GST-EV71-VP2/131-160 peptide. The MuscFv of clone 83 (MuscFv83), which produced the highest ELISA signal to the target antigen, was further tested. MuscFv83 also bound to full-length EV71-VP2 and EV71 particles, but did not bind to GST, full-length EV71-VP1, or the antigenically related CA16. MuscFv83 could be a suitable reagent for rapid antigen-based immunoassay, such as immunochromatography (ICT), for the specific detection and/or diagnosis of EV71 infection as well as epidemic surveillance.

  4. Magnetic behavior of Si-Ge bond in SixGe4-x nano-clusters

    Science.gov (United States)

    Nahali, Masoud; Mehri, Ali

    2018-06-01

    The structure of SixGe4-x nano-clusters were optimized by MPW1B95 level of theory using MG3S and SDB-aug-cc-PVTZ basis set. The agreement of the calculated ionization and dissociation energies with experimental values validates the reported structures of nano-clusters and justifies the use of hybrid meta density functional method. Since the Si-Si bond is stronger than Si-Ge and Ge-Ge bonds, the Si-Si, Si-Ge, and Ge-Ge diagonal bonds determine the precedence of the stability in these nano-clusters. The hybrid meta density functional calculations were carried out to investigate the adsorption of CO on all possible SixGe4-x nano-clusters. It was found that the silicon atom generally makes a stronger bond with CO than germanium and thereby preferentially affects the shape of structures having higher multiplicity. In Si-Ge structures with higher spin more than 95% of spins accumulate on positions with less bonds to other atoms of the cluster. Through CO adsorption on these clusters bridge structures are made that behave as spin bridge which conduct the spin from the nano-cluster surface to the adsorbate atoms. A better understanding of bridged structures was achieved upon introducing the 'spin bridge' concept. Based on exhaustive spin density analysis, it was found that the reason for the extra negative charge on oxygen in the bridged structures is the relocation of spin from the surface through the bridge.

  5. Evaluation of bone-seeking novel radiotracer {sup 68}Ga-NO2AP-Bisphosphonate for the detection of skeletal metastases in carcinoma breast

    Energy Technology Data Exchange (ETDEWEB)

    Passah, Averilicia; Tripathi, Madhavi; Ballal, Sanjana; Yadav, Madhav Prasad; Kumar, Rajeev; Chakraborty, Partha Sarathi; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, Ansari Nagar, New Delhi (India); Roesch, Frank; Meckel, Marian [Johannes-Gutenberg-University, Nuclear Chemistry, Mainz (Germany)

    2017-01-15

    The successful labelling of bisphosphonates (BP) with {sup 68}Ga using macrocyclic chelators such as the based triazacyclononane (NO2AP) is a step forward in the in-house availability of a novel bone-seeking PET radiopharmaceutical with dual advantage of PET/CT imaging and generator production. In this study, we compared the novel generator-based skeletal radiotracer {sup 68}Ga-1,4,7-triazacyclonone-1,4-diacetic acid ({sup 68}Ga-NO2AP-BP) with sodium fluoride ({sup 18}F-NaF) for the detection of skeletal metastases in breast cancer patients. In addition, dosimetric analysis of {sup 68}Ga-NO2AP-BP was performed in a subset of patients. This was a prospective study of histopathologically proven cases of breast cancer patients who were referred for bone scintigraphy and underwent positron emission tomography/computed tomography (PET/CT) with {sup 18}F-NaF and {sup 68}Ga-NO2AP-BP within a week in random order. The scans of each patient were compared both qualitatively for image quality and quantitatively for number of lesions and SUVmax of lesions. Dosimetric analysis was performed in five patients. Their PET/CT scans were acquired at multiple time points and urine and blood samples were collected. Dosimetric calculations were performed using OLINDA/EXM 1.1 software. Statistical analysis was done using Stata 13 (StataCorp) software package. An agreement analysis regarding number of lesions detected with the two skeletal radiotracers was carried out. The image quality of {sup 68}Ga-NO2AP-BP PET/CT scans were comparable to that of {sup 18}F-NaF. There was no statistically significant difference in the SUVmax of lesions, normal bone and lesion to background ratio between the two skeletal radiotracers. There was good agreement in the number of lesions detected by both skeletal radiotracers. The mean whole body effective dose for {sup 68}Ga-NO2AP-BP was 0.00583 mSv/MBq and the effective dose equivalent was 0.0086 mSv/MBq. The excellent lesion detection agreement between

  6. Towards rhombohedral SiGe epitaxy on 150mm c-plane sapphire substrates

    Science.gov (United States)

    Duzik, Adam J.; Park, Yeonjoon; Choi, Sang H.

    2015-04-01

    Previous work demonstrated for the first time the ability to epitaxially grow uniform single crystal diamond cubic SiGe (111) films on trigonal sapphire (0001) substrates. While SiGe (111) forms two possible crystallographic twins on sapphire (0001), films consisting primarily of one twin were produced on up to 99.95% of the total wafer area. This permits new bandgap engineering possibilities and improved group IV based devices that can exploit the higher carrier mobility in Ge compared to Si. Models are proposed on the epitaxy of such dissimilar crystal structures based on the energetic favorability of crystallographic twins and surface reconstructions. This new method permits Ge (111) on sapphire (0001) epitaxy, rendering Ge an economically feasible replacement for Si in some applications, including higher efficiency Si/Ge/Si quantum well solar cells. Epitaxial SiGe films on sapphire showed a 280% increase in electron mobility and a 500% increase in hole mobility over single crystal Si. Moreover, Ge possesses a wider bandgap for solar spectrum conversion than Si, while the transparent sapphire substrate permits an inverted device structure, increasing the total efficiency to an estimated 30-40%, much higher than traditional Si solar cells. Hall Effect mobility measurements of the Ge layer in the Si/Ge/Si quantum well structure were performed to demonstrate the advantage in carrier mobility over a pure Si solar cell. Another application comes in the use of microelectromechanical devices technology, where high-resistivity Si is currently used as a substrate. Sapphire is a more resistive substrate and offers better performance via lower parasitic capacitance and higher film carrier mobility over the current Si-based technology.

  7. The relationship between structural and optical properties of Se-Ge-As glasses

    Science.gov (United States)

    Ghayebloo, M.; Rezvani, M.; Tavoosi, M.

    2018-05-01

    In this study, the structural and optical characterization of bulk Se-Ge-As glasses has been investigated. In this regards, six different Se60Ge40-xAsx (0 ≤ x ≤ 25) glasses were prepared by conventional melt quenching technique in quartz ampoule. The produced samples were characterized using X-ray diffraction (XRD), Raman spectroscopy, differential thermal analysis (DTA), ultraviolet-visible (UV-Vis) and Fourier transform infrared (FTIR) spectroscopy. The fundamental absorption edge for all the glasses was analyzed in terms of the theory proposed by Davis and Mott. According to achieved results, fully amorphous phase can easily form in different Se-Ge-As systems. The thermal and optical characteristic of Se60Ge40-xAsx glasses shows anomalous behavior at 5 mol% of As for the glass transition temperature, transmittance, absorption edge, optical energy gap and Urbach energy. The highest glass transition temperature, transmittance, optical energy gap and Urbach energy properties were achieved in Se60Ge35As5 glass as a result of the highest connectivity of cations and anions in glass network.

  8. Optical and structural characterization of Ge clusters embedded in ZrO2

    Science.gov (United States)

    Agocs, E.; Zolnai, Z.; Rossall, A. K.; van den Berg, J. A.; Fodor, B.; Lehninger, D.; Khomenkova, L.; Ponomaryov, S.; Gudymenko, O.; Yukhymchuk, V.; Kalas, B.; Heitmann, J.; Petrik, P.

    2017-11-01

    The change of optical and structural properties of Ge nanoclusters in ZrO2 matrix have been investigated by spectroscopic ellipsometry versus annealing temperatures. Radio-frequency top-down magnetron sputtering approach was used to produce the samples of different types, i.e. single-layers of pure Ge, pure ZrO2 and Ge-rich-ZrO2 as well as multi-layers stacked of 40 periods of 5-nm-Ge-rich-ZrO2 layers alternated by 5-nm-ZrO2 ones. Germanium nanoclusters in ZrO2 host were formed by rapid-thermal annealing at 600-800 °C during 30 s in nitrogen atmosphere. Reference optical properties for pure ZrO2 and pure Ge have been extracted using single-layer samples. As-deposited multi-layer structures can be perfectly modeled using the effective medium theory. However, annealed multi-layers demonstrated a significant diffusion of elements that was confirmed by medium energy ion scattering measurements. This fact prevents fitting of such annealed structure either by homogeneous or by periodic multi-layer models.

  9. Ultra-smooth epitaxial Ge grown on Si(001) utilizing a thin C-doped Ge buffer layer

    KAUST Repository

    Mantey, J.

    2013-01-01

    Here, we present work on epitaxial Ge films grown on a thin buffer layer of C doped Ge (Ge:C). The growth rate of Ge:C is found to slow over time and is thus unsuitable for thick (>20 nm) layers. We demonstrate Ge films from 10 nm to >150 nm are possible by growing pure Ge on a thin Ge:C buffer. It is shown that this stack yields exceedingly low roughness levels (comparable to bulk Si wafers) and contains fewer defects and higher Hall mobility compared to traditional heteroepitaxial Ge. The addition of C at the interface helps reduce strain by its smaller atomic radius and its ability to pin defects within the thin buffer layer that do not thread to the top Ge layer. © 2013 AIP Publishing LLC.

  10. Water-vapor-enhanced growth of Ge-GeOx core-shell nanowires and Si1-xGexOy nanowires

    International Nuclear Information System (INIS)

    Hsu, T-J; Ko, C-Y; Lin, W-T

    2007-01-01

    The effects of moist Ar on the growth of Ge-GeO x core-shell nanowires (Ge-GeO x NWs) and Si 1-x Ge x O y nanowires (SiGeONWs) on Si substrates without adding a metal catalyst via the carbothermal reduction of GeO 2 powders at 1100 deg. C were studied. No significant nanowires were grown in dry Ar at a flow rate of 100-300 sccm until a bit of water in the range of 0.5-2 ml was loaded into the furnace. More water suppressed the growth of nanowires because of the exhaustion of more graphite powder. The growth of Ge-GeO x NWs and SiGeONWs follows the vapor-solid and vapor-liquid-solid processes, respectively. The present study showed that the water vapor serves as an oxidizer as well as a reducer at 1100 deg. C in enhancing the growth of SiGeONWs and Ge-GeO x NWs, respectively. The growth mechanisms of Ge-GeO x NWs and SiGeONWs are also discussed

  11. Thin SiGe virtual substrates for Ge heterostructures integration on silicon

    International Nuclear Information System (INIS)

    Cecchi, S.; Chrastina, D.; Frigerio, J.; Isella, G.; Gatti, E.; Guzzi, M.; Müller Gubler, E.; Paul, D. J.

    2014-01-01

    The possibility to reduce the thickness of the SiGe virtual substrate, required for the integration of Ge heterostructures on Si, without heavily affecting the crystal quality is becoming fundamental in several applications. In this work, we present 1 μm thick Si 1−x Ge x buffers (with x > 0.7) having different designs which could be suitable for applications requiring a thin virtual substrate. The rationale is to reduce the lattice mismatch at the interface with the Si substrate by introducing composition steps and/or partial grading. The relatively low growth temperature (475 °C) makes this approach appealing for complementary metal-oxide-semiconductor integration. For all the investigated designs, a reduction of the threading dislocation density compared to constant composition Si 1−x Ge x layers was observed. The best buffer in terms of defects reduction was used as a virtual substrate for the deposition of a Ge/SiGe multiple quantum well structure. Room temperature optical absorption and photoluminescence analysis performed on nominally identical quantum wells grown on both a thick graded virtual substrate and the selected thin buffer demonstrates a comparable optical quality, confirming the effectiveness of the proposed approach

  12. Processing high-Tc superconductors with GeV heavy ions

    International Nuclear Information System (INIS)

    Marwick, A.D.; Civale, L.; Krusin-Elbaum, L.; Worthington, T.K.; Holtzberg, F.; Thompson, J.R.; Sun, Y.R.; Kerchner, H.R.

    1992-01-01

    Irradiation of high-T c superconducting crystals with low doses (10 10 --10 11 ions/cm 2 ) of GeV heavy ions (0.58 GeV Sn-116; 1.0-GeV Au-197) produces a unique microstructure consisting of discrete amorphous columns which are only a few nm in diameter but tens of microns long. It has been found recently that this columnar microstructure causes larger increases in magnetization and critical current at high temperature and high magnetic field than other types of defects in these materials. This can be understood as a consequence of the effective pinning of magnetic vortex lines provided by the columnar defects. Measurements confirm that the pinning is strongest when the magnetic field is aligned with the ion tracks. Differences in the pinning in different materials can be related to differences in their anisotropy, which affects the structure of the vortices and their pinning at columnar defects

  13. A Search for Centrally Produced Non- $\\overline{q}q$ Mesons in Proton Proton Interactions at 450 GeV/c by Using the CERN $\\Omega$ Spectrometer

    CERN Multimedia

    2002-01-01

    The aim of this experiment is to search for non-$q \\bar{q}$ mesons produced in the central region in the reaction pp~$\\rightarrow$~$ p _{f} (X ^0)p _{s} $ at 450 GeV/c, where the subscripts f~and s~indicate the fastest and slowest particles in the laboratory respectively and X$^0$ represents the central system that is presumed to be produced by double exchange processes. The state X$^0$ will be studied in many decay modes, e.g. $ \\pi ^+ \\pi ^-, pi ^+ \\pi ^- \\pi ^0, 2 \\pi ^+ 2 \\pi ^-, 2 \\pi ^+ 2 \\pi ^- \\pi ^0, eta \\pi ^+ \\pi ^-, \\omega \\pi ^+ \\pi ^-, K ^+ K ^- , K ^+ K ^- \\pi ^0 , K ^0 _{s} K ^\\pm \\pi ^- , K ^+ K ^- \\pi ^+ \\pi ^- , 2K ^\\pm 2K ^\\pm , K ^0 _{s} K ^0 _{s} , K ^0 _{s} K ^0 _{s} \\pi ^0 , $ $\\eta

  14. Radiotracer technique to study movement of pollutants in an alluvial aquifer

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2001-01-01

    Radioisotopes are being used as tracers in many research areas. Their use in determination of groundwater flow velocity is well known. They also provide insight into the understanding the hydrological systems. In this paper, pollutant movement in an alluvial aquifer in the Ganga basin near Kanpur is evaluated using radiotracer method. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater in the vicinity of an effluent storage lagoon of a fertilizer plant at Kanpur, U.P. Point dilution technique in a single well was applied. Filtration velocity so obtained provided relevant information about the pollutant movement in the groundwater. (author)

  15. Thermal transport through Ge-rich Ge/Si superlattices grown on Ge(0 0 1)

    Science.gov (United States)

    Thumfart, L.; Carrete, J.; Vermeersch, B.; Ye, N.; Truglas, T.; Feser, J.; Groiss, H.; Mingo, N.; Rastelli, A.

    2018-01-01

    The cross-plane thermal conductivities of Ge-rich Si/Ge superlattices have been measured using both time-domain thermoreflectance and the differential 3ω method. The superlattices were grown by molecular beam epitaxy on Ge(0 0 1) substrates. Crystal quality and structural information were investigated by x-ray diffractometry and transmission electron microscopy. The influence of segregation during growth on the composition profiles was modeled using the experimental growth temperatures and deposition rates. Those profiles were then employed to obtain parameter-free theoretical estimates of the thermal conductivity by combining first-principles calculations, Boltzmann transport theory and phonon Green’s functions. Good agreement between theory and experiment is observed. The thermal conductivity shows a strong dependence on the composition and the thickness of the samples. Moreover, the importance of the composition profile is reflected in the fact that the thermal conductivity of the superlattices is considerably lower than predicted values for alloys with the same average composition and thickness. Measurement on different samples with the same Si layer thickness and number of periods, but different Ge layer thickness, show that the thermal resistance is only weakly dependent on the Ge layers. We analyze this phenomenon based on the first-principles mode, and build an approximate parametrization showing that, in this regime, the resistivity of a SL is roughly linear on the amount of Si.

  16. Changing the PEP-II Center-of-Mass Energy Down to 10 GeV and up to 11 GeV

    International Nuclear Information System (INIS)

    Sullivan, M.

    2009-01-01

    PEP-II, the SLAC, LBNL, LLNL B-Factory was designed and optimized to run at the Upsilon 4S resonance (10.580 GeV with an 8.973 GeV e- beam and a 3.119 GeV e+ beam). The interaction region (IR) used permanent magnet dipoles to bring the beams into a head-on collision. The first focusing element for both beams was also a permanent magnet. The IR geometry, masking, beam orbits and beam pipe apertures were designed for 4S running. Even though PEP-II was optimized for the 4S, we successfully changed the center-of-mass energy (E cm ) down to the Upsilon 2S resonance and completed an E cm scan from the 4S resonance up to 11.2 GeV. The luminosity throughout most of these changes remained near 1 x 10 34 cm -2 s -1 . The E cm was changed by moving the energy of the high-energy beam (HEB). The beam energy differed by more than 20% which produced significantly different running conditions for the RF system. The energy loss per turn changed 2.5 times over this range. We describe how the beam energy was changed and discuss some of the consequences for the beam orbit in the interaction region. We also describe some of the RF issues that arose and how we solved them as the high-current HEB energy changed

  17. Neutron capture cross sections of $^{70,72,73,74,76}$ Ge at n_TOF EAR-1

    CERN Multimedia

    We propose to measure the (n;$\\gamma$ ) cross sections of the isotopes $^{70;72;73;74;76}$Ge. Neutron induced reactions on Ge are of importance for the astrophysical slow neutron capture process, which is responsible for forming about half of the overall elemental abundances heavier than Fe. The neutron capture cross section on Ge affects the abundances produced in this process for a number of heavier isotopes up to a mass number of A = 90. Additionally, neutron capture on Ge is of interest for low background experiments involving Ge detectors. Experimental cross section data presently available for Ge (n;$\\gamma$ ) are scarce and cover only a fraction of the neutron energy range of interest. (n;$\\gamma$ ) cross sections will be measured in the full energy range from 25 meV to about 200 keV at n TOF EAR-1.

  18. Ultra-smooth epitaxial Ge grown on Si(001) utilizing a thin C-doped Ge buffer layer

    KAUST Repository

    Mantey, J.; Hsu, W.; James, J.; Onyegam, E. U.; Guchhait, S.; Banerjee, S. K.

    2013-01-01

    Here, we present work on epitaxial Ge films grown on a thin buffer layer of C doped Ge (Ge:C). The growth rate of Ge:C is found to slow over time and is thus unsuitable for thick (>20 nm) layers. We demonstrate Ge films from 10 nm to >150 nm

  19. Observation of spin alignment of resonances produced in the 3-body reactions : $\\overline{p}$p $\\rightarrow$ $\\overline{p}$p $\\omega^{\\omicron}$ and $\\overline{p}$p $\\rightarrow$ $\\overline{N}^{x++}\\pi^{\\omicron}$ at 5.7 GeV/c

    CERN Document Server

    Alles-Borelli, V; Frisk, A; Michejda, L

    1966-01-01

    Observation of spin alignment of resonances produced in the 3-body reactions : $\\overline{p}$p $\\rightarrow$ $\\overline{p}$p $\\omega^{\\omicron}$ and $\\overline{p}$p $\\rightarrow$ $\\overline{N}^{x++}\\pi^{\\omicron}$ at 5.7 GeV/c

  20. Luminescence of one dimensional ZnO, GeO{sub 2}–Zn{sub 2}GeO{sub 4} nanostructure through thermal evaporation of Zn and Ge powder mixture

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Vuong-Hung, E-mail: vuong.phamhung@hust.edu.vn; Kien, Vu Trung; Tam, Phuong Dinh; Huy, Pham Thanh

    2016-07-15

    Graphical abstract: - Highlights: • ZnO and GeO{sub 2}–ZnGeO{sub 4} nanowires were fabricated by thermal evaporation of Zn and Ge powder mixture. • Morphology of specimens were observed to have a nanowire structure to rod-like morphology. • Strong NBE emission band with suppressed visible green emission band were observed on the dominant ZnO nanowires. • Strong emission of ∼530 nm were observed on the GeO{sub 2}–Zn{sub 2}GeO{sub 4} nanowires. - Abstract: This paper reports the first attempt for fabrication of thermal evaporated Zn–Ge powder mixture to achieve near-band-edge (NBE) emission of ZnO and visible emission of GeO{sub 2}–Zn{sub 2}GeO{sub 4} nanowires with controllable intensities. The nanowires were fabricated by thermal evaporation of Zn and Ge powder mixture, particularly, by using different Zn:Ge ratio, temperature and evaporated times. The morphology of nanowires was depended on the Zn and Ge ratio that was observed to have a nanowire structure to rod-like morphology. The thermal evaporation of Zn:Ge powder mixture resulted in formation of dominant ZnO or GeO{sub 2}–Zn{sub 2}GeO{sub 4} nanowires as a function of evaporated parameters. These results suggest that the application of thermal evaporation of Zn and Ge mixture for potential application in synthesis of ZnO or GeO{sub 2}–Zn{sub 2}GeO{sub 4} nanowires for optoelectronic field.

  1. Protective effect of enterovirus‑71 (EV71) virus‑like particle vaccine against lethal EV71 infection in a neonatal mouse model.

    Science.gov (United States)

    Cao, Lei; Mao, Fengfeng; Pang, Zheng; Yi, Yao; Qiu, Feng; Tian, Ruiguang; Meng, Qingling; Jia, Zhiyuan; Bi, Shengli

    2015-08-01

    Enterovirus-71 (EV71) is a viral pathogen that causes severe cases of hand, foot and mouth disease (HFMD) among young children, with significant mortality. Effective vaccines against HFMD are urgently required. Several EV71 virus-like particle (VLP) vaccine candidates were found to be protective in the neonatal mouse EV71 challenge model. However, to what extent the VLP vaccine protects susceptible organs against EV71 infection in vivo has remained elusive. In the present study, the comprehensive immunogenicity of a potential EV71 vaccine candidate based on VLPs was evaluated in a neonatal mouse model. Despite lower levels of neutralizing antibodies to EV71 in the sera of VLP-immunized mice compared with those in mice vaccinated with inactivated EV71, the VLP-based vaccine was shown to be able to induce immunoglobulin (Ig)G and IgA memory-associated cellular immune responses to EV71. Of note, the EV71 VLP vaccine candidate was capable of inhibiting viral proliferation in cardiac muscle, skeletal muscle, lung and intestine of immunized mice and provided effective protection against the pathological damage caused by viral attack. In particular, the VLP vaccine was able to inhibit the transportation of EV71 from the central nervous system to the muscle tissue and greatly protected muscle tissue from infection, along with recovery from the viral infection. This led to nearly 100% immunoprotective efficacy, enabling neonatal mice delivered by VLP-immunized female adult mice to survive and grow with good health. The present study provided valuable additional knowledge of the specific protective efficacy of the EV71 VLP vaccine in vivo, which also indicated that it is a promising potential candidate for being developed into an EV71 vaccine.

  2. Muon channeling in Ge: Evidence for pionium formation

    International Nuclear Information System (INIS)

    Flik, G.; Bradbury, J.N.; Cooke, D.W.; Heffner, R.H.; Leon, M.; Paciotti, M.A.; Schillaci, M.E.; Maier, K.; Rempp, H.; Boekema, C.; Reidy, J.J.; Daniel, H.

    1986-01-01

    In a recent experiment observing muon channeling from the decay of positive pions implanted in high-purity Ge single crystals, the pion decay site is found to be sensitive to the concentration of excess charge carriers produced by photon absorption. Distinctly different channeling profiles are observed in Ge at 100 K for illuminated samples (high carrier concentration) as compared to unilluminated samples (low carrier concentration). From these data we conclude that different electronic states of the pion in a semiconductor host lattice must account for the observed changes in the pion location. Furthermore we suggest that the pion exists in the solid both as the bare entity π + and as pionium (π + e - ), i.e., a hydrogen-like atom with a mesonic nucleus. (orig.)

  3. Vulnerability of positron emission tomography radiotracers to endogenous competition

    International Nuclear Information System (INIS)

    Laruelle, M.; Huang, Y.

    2001-01-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels

  4. Vulnerability of positron emission tomography radiotracers to endogenous competition

    Energy Technology Data Exchange (ETDEWEB)

    Laruelle, M.; Huang, Y. [Columbia University College of Physicians and Surgeons and State Psychiatric Institute, Dept. of Psychiatry and Radiology, New York, NY (United States)

    2001-06-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels.

  5. The influence of molecular weight in radiotracers of inflamators processes

    International Nuclear Information System (INIS)

    Mesa Duennas, N.; Zayas Crespo, F.; Piedra Mazorra, J.; Diaz Barreto, M; Rodriguez Alfonso, M.E.; Perez Fuentes, A.

    2004-01-01

    Four 99mTc-radiopharmaceuticals (RPs) were compared as a radiotracers of inflammatory process. The RPs were divided in two groups according to their molecular weights and nature. One group included the human IgG and the ior t3 MoAb (anti-CD3), another included the Ciprofloxacine and the DMSA. The RPs were studied by different quality controls, and a biodistribution study in an aseptic inflammatory model made by steril Carragenin. The results obtained in the reduction of the immunoglobulins with 2-mercaptoethanol and sodium metabisulphite demonstrated that both reducing agents were equivalent, because the radiochemical purity obtained were similar and independent of the immunoglobulins. The biodistribution demonstrated a higher incorporation for the radiopharmaceuticals of high molecular weight, and the highest values were obtained with the 2-mercaptoethanol

  6. Quality control for measurement of soil samples containing 237Np and 241Am as radiotracer

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhang Caihong; Song Hailong; Ren Xiaona; Han Yuhu; Zhang Aiming; Chu Taiwei

    2003-01-01

    This paper reports quality control (QC) for the measurement of soil samples containing 237 Np and 241 Am as radiotracers in migration test of transuranic nuclides. All of the QC were done independently by the QA members of analytical work. It mainly included checking 5%-10% of the total analyzed samples; preparing blank samples, blind replicate sample and spiked samples used as quality control samples to check the quality of analytical work

  7. Precipitation and strengthening phenomena in Al-Si-Ge and Al-Cu-Si-Ge alloys

    International Nuclear Information System (INIS)

    Mitlin, D.; Morris, J.W.; Dahmen, U.; Radmilovic, V.

    2000-01-01

    The objective of this work was to determine whether Al rich Al-Si-Ge and 2000 type Al-Cu-Si-Ge alloys have sufficient hardness to be useful for structural applications. It is shown that in Al-Si-Ge it is not possible to achieve satisfactory hardness through a conventional heat treatment. This result is explained in terms of sluggish precipitation of the diamond-cubic Si-Ge phase coupled with particle coarsening. However, Al-Cu-Si-Ge displayed a uniquely fast aging response, a high peak hardness and a good stability during prolonged aging. The high hardness of the Cu containing alloy is due to the dense and uniform distribution of fine θ' precipitates (metastable Al 2 Cu) which are heterogeneously nucleated on the Si-Ge particles. High resolution TEM demonstrated that in both alloys all the Si-Ge precipitates start out, and remain multiply twinned throughout the aging treatment. Since the twinned section of the precipitate does not maintain a low index interface with the matrix, the Si-Ge precipitates are equiaxed in morphology. Copyright (2000) AD-TECH - International Foundation for the Advancement of Technology Ltd

  8. PET imaging of HSV1-tk mutants with acquired specificity toward pyrimidine- and acycloguanosine-based radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Likar, Yury; Dobrenkov, Konstantin; Olszewska, Malgorzata; Shenker, Larissa; Hricak, Hedvig; Ponomarev, Vladimir [Memorial Sloan-Kettering Cancer Center, Molecular Imaging Laboratory, Department of Radiology, New York, NY (United States); Cai, Shangde [Memorial Sloan-Kettering Cancer Center, Radiochemistry/Cyclotron Core Facility, New York, NY (United States)

    2009-08-15

    The aim of this study was to create an alternative mutant of the herpes simplex virus type 1 thymidine kinase (HSV1-tk) reporter gene with reduced phosphorylation capacity for acycloguanosine derivatives, but not pyrimidine-based compounds that will allow for successful PET imaging. A new mutant of HSV1-tk reporter gene, suitable for PET imaging using pyrimidine-based radiotracers, was developed. The HSV1-tk mutant contains an arginine-to-glutamine substitution at position 176 (HSV1-R176Qtk) of the nucleoside binding region of the enzyme. The mutant-gene product showed favorable enzymatic characteristics toward pyrimidine-based nucleosides, while exhibiting reduced activity with acycloguanosine derivatives. In order to enhance HSV1-R176Qtk reporter activity with pyrimidine-based radiotracers, we introduced the R176Q substitution into the more active HSV1-sr39tk mutant. U87 human glioma cells transduced with the HSV1-R176Qsr39tk double mutant reporter gene showed high {sup 3}H-FEAU pyrimidine nucleoside and low {sup 3}H-penciclovir acycloguanosine analog uptake in vitro. PET imaging also demonstrated high {sup 18}F-FEAU and low {sup 18}F-FHBG accumulation in HSV1-R176Qsr39tk+ xenografts. The feasibility of imaging two independent nucleoside-specific HSV1-tk mutants in the same animal with PET was demonstrated. Two opposite xenografts expressing the HSV1-R176Qsr39tk reporter gene and the previously described acycloguanosine-specific mutant of HSV1-tk, HSV1-A167Ysr39tk reporter gene, were imaged using a short-lived pyrimidine-based {sup 18}F-FEAU and an acycloguanosine-based {sup 18}F-FHBG radiotracer, respectively, administered on 2 consecutive days. We conclude that in combination with acycloguanosine-specific HSV1-A167Ysr39tk reporter gene, a HSV1-tk mutant containing the R176Q substitution could be used for PET imaging of two different cell populations or concurrent molecular biological processes in the same living subject. (orig.)

  9. Molecular beam epitaxy growth of [CrGe/MnGe/FeGe] superlattices: Toward artificial B20 skyrmion materials with tunable interactions

    Science.gov (United States)

    Ahmed, Adam S.; Esser, Bryan D.; Rowland, James; McComb, David W.; Kawakami, Roland K.

    2017-06-01

    Skyrmions are localized magnetic spin textures whose stability has been shown theoretically to depend on material parameters including bulk Dresselhaus spin orbit coupling (SOC), interfacial Rashba SOC, and magnetic anisotropy. Here, we establish the growth of a new class of artificial skyrmion materials, namely B20 superlattices, where these parameters could be systematically tuned. Specifically, we report the successful growth of B20 superlattices comprised of single crystal thin films of FeGe, MnGe, and CrGe on Si(1 1 1) substrates. Thin films and superlattices are grown by molecular beam epitaxy and are characterized through a combination of reflection high energy electron diffraction, X-ray diffraction, and cross-sectional scanning transmission electron microscopy (STEM). X-ray energy dispersive spectroscopy (XEDS) distinguishes layers by elemental mapping and indicates good interface quality with relatively low levels of intermixing in the [CrGe/MnGe/FeGe] superlattice. This demonstration of epitaxial, single-crystalline B20 superlattices is a significant advance toward tunable skyrmion systems for fundamental scientific studies and applications in magnetic storage and logic.

  10. Technetium-99 behavior in the terrestrial environment. Field observations and radiotracer experiments

    International Nuclear Information System (INIS)

    Tagami, Keiko

    2003-01-01

    Obtaining data on 99 Tc in the rice paddy field environment is important because Tc is a redox sensitive element. The behavior of Tc is expected to be different under upland field and rice paddy field conditions since the redox conditions in the soil environment differ. However, most of the data on the nuclide behavior in soil were obtained under upland field conditions. To understand the global fallout 99 Tc distributions in soil samples collected in Japan, a simple and rapid separation method was developed in order to determine low-levels of 99 Tc in soil samples by an inductively coupled plasma mass spectrometry. Also, radiotracer experiments using soils under aerobic and anaerobic conditions were carried out to clarify the Tc behavior under paddy field conditions. The results of determination of global fallout 99 Tc in Japanese soils indicated that the radionuclide had been accumulating in rice paddy fields. The mechanisms can be explained by the immobilization of Tc in soil under anaerobic conditions. From the radiotracer experiments, it was clear that under waterlogged conditions, the highly mobile TcO 4 - in soil was readily changed to other immobilized forms, such as TcO 2 , TcS 2 and organically bound forms. To this immobilization, the microbial activity seemed to have an important role in Tc sorption reactions. When the soil, which was once kept in anaerobic conditions, was air-dried again and kept in aerobic conditions, the chemical forms of immobilized Tc did not change remarkably. Interestingly, the similar Tc behavior was observed in a real wet forest near the Chernobyl Reactor. (author)

  11. Alleviation of Fermi level pinning at metal/n-Ge interface with lattice-matched Si x Ge1‑ x ‑ y Sn y ternary alloy interlayer on Ge

    Science.gov (United States)

    Suzuki, Akihiro; Nakatsuka, Osamu; Sakashita, Mitsuo; Zaima, Shigeaki

    2018-06-01

    The impact of a silicon germanium tin (Si x Ge1‑ x ‑ y Sn y ) ternary alloy interlayer on the Schottky barrier height (SBH) of metal/Ge contacts with various metal work functions has been investigated. Lattice matching at the Si x Ge1‑ x ‑ y Sn y /Ge heterointerface is a key factor for controlling Fermi level pinning (FLP) at the metal/Ge interface. The Si x Ge1‑ x ‑ y Sn y ternary alloy interlayer having a small lattice mismatch with the Ge substrate can alleviate FLP at the metal/Ge interface significantly. A Si0.11Ge0.86Sn0.03 interlayer increases the slope parameter for the work function dependence of the SBH to 0.4. An ohmic behavior with an SBH below 0.15 eV can be obtained with Zr and Al/Si0.11Ge0.86Sn0.03/n-Ge contacts at room temperature.

  12. Extraction of the mixture 99mTcO4- tributilfosfato- 30% 16% trioctylamine in cyclohexane evaluation of radiotracer obtained

    International Nuclear Information System (INIS)

    Ortega Pijeira, Martha Sahyli; Dominguez Catasus, Judith; Martinez Baez, Ernesto; Borroto Portela, Jorge

    2014-01-01

    Tracer technology plays an important role in industry development and has been widely used to optimize process, solve problems and improve product quality. In the last years Cuban scientific have studied the 99m TcO 4 - , eluted from 99 Mo/ 99m Tc generator, extraction with the mixture 30 % tributylphosphate -16 % trioctylamine in cyclohexane, in order to get an organic radiotracer. In this paper, the influence on 99m TcO 4 - extraction of stirring speed, contact time and NaCl concentration were studied. The extractant's role was also studied and, the tracer's homogeneity in diesel, special gasoline and Venezuelan oils was evaluated to normal pressure and temperature. The obtained outcomes showed that the NaCl concentration only influences on the extraction process when it is less than 0.17 %. Furthermore, the employed mixture's synergism was noticed and, could be conclude that, the obtained tracer is a physical radiotracer for the used industrial supports to 95 % trustworthy

  13. A simple and efficient in vitro method for metabolism studies of radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang-Yoon; Choe, Yearn Seong E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Byung-Tae

    2001-05-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[{sup 18}F]fluoromethylbenzyl- ([{sup 18}F]1) and 4-[{sup 18}F]fluorobenzyl-piperidine moieties ([{sup 18}F]2) was studied and compared with the in vivo metabolism. Defluorination of the [{sup 18}F]1 mainly occurred to generate [{sup 18}F]fluoride ion both in vitro and in vivo. In contrast, the [{sup 18}F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[{sup 18}F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers.

  14. 75 FR 47318 - GE Asset Management Incorporated and GE Investment Distributors, Inc.; Notice of Application and...

    Science.gov (United States)

    2010-08-05

    ...] GE Asset Management Incorporated and GE Investment Distributors, Inc.; Notice of Application and.... Applicants: GE Asset Management Incorporated (``GEAM'') and GE Investment Distributors, Inc. (``GEID... of Investment Management, Office of Investment Company Regulation). SUPPLEMENTARY INFORMATION: The...

  15. Study of wastewater treatment plants efficiency using radiotracers

    International Nuclear Information System (INIS)

    Dawi, W. D. A.

    2010-11-01

    This study was performed to investigate and diagnose hydrodynamic behavior of the Military Hospital wastewater treatment plant. The plant comprises two units of treatment, each of them has a separate system. The investigation was carried out using ''1''3''1I as a radiotracer. The concept of residence time distribution (RTD) was used to investigate the efficiency of the aeration tanks, secondary clarifiers and chlorine tanks. Preliminary treatment and modeling of the trace data was performed using two software package applied by the International Atomic Energy Agency (IAEA) namely 4621 counter version 1.0.0 and RTD software. Plug flow pattern (parallel flow) was detected in the aeration tank and secondary clarifier of system 1 in one unit, while no homogeneous mixing was observed in the chlorine tank. Short - circuiting (by - passing) was evident in the aeration tank of system 2 in the other unit, which significantly reduced the operating efficiency. The percentage of dead volumes clearly suggests that the aeration tank and secondary clarifier were well utilized in the whole plant. (Author)

  16. The association between enterovirus 71 infections and meteorological parameters in Taiwan.

    Directory of Open Access Journals (Sweden)

    Hsiao-Ling Chang

    Full Text Available BACKGROUND: Enterovirus 71 (EV71 infections are a significant cause of neurological disorder and death in children worldwide. Seasonal variations in EV71 infections have been recognized, but the mechanisms responsible for this phenomenon remain unknown. The purpose of this study was to examine the relationship between meteorological parameters and EV71 infection. METHODS AND FINDINGS: We analyzed the number of EV71 infections and daily climate data collected in Taiwan between 1998 and 2008 and used Poisson regression analysis and case-crossover methodology to evaluate the association between weather variability and the incidence of EV71 infection. A total of 1,914 EV71-infected patients were reported between 1998 and 2008. The incidence of EV71 infections reflected significant summertime seasonality (for oscillation, p<0.001. The incidence of EV71 infections began to rise at temperatures above 13°C (r(2 = 0.76, p<0.001; at temperatures higher than approximately 26°C (r(2 = 0.94, p<0.05, the incidence began to decline, producing an inverted V-shaped relationship. The increase in the incidence with increasing relative humidity was positive and linear (r(2 = 0.68, p<0.05. EV71 infection was most highly correlated with temperature and relative humidity in the period that likely preceded the infection. CONCLUSION: Our study provides quantitative evidence that the rate of EV71 infection increased significantly with increasing mean temperature and relative humidity in Taiwan.

  17. Investigation on the dominant key to achieve superior Ge surface passivation by GeOx based on the ozone oxidation

    International Nuclear Information System (INIS)

    Wang, Xiaolei; Xiang, Jinjuan; Wang, Wenwu; Xiong, Yuhua; Zhang, Jing; Zhao, Chao

    2015-01-01

    Highlights: • The dominant key to achieve superior Ge passivation by GeO x is investigated. • The interface state density decreases with increasing the GeO x thickness. • The Ge 3+ oxide component is the dominant key to passivate the Ge surface. • The atomic structure at the GeO x /Ge interface is built by XPS. - Abstract: The dominant key to achieve superior Ge surface passivation by GeO x interfacial layer is investigated based on ozone oxidation. The interface state density (D it ) measured from low temperature conduction method is found to decrease with increasing the GeO x thickness (0.26–1.06 nm). The X-ray photoelectron spectroscopy (XPS) is employed to demonstrate the interfacial structure of GeO x /Ge with different GeO x thicknesses. And the XPS results show that Ge 3+ oxide component is responsible to the decrease of the D it due to the effective passivation of Ge dangling bonds. Therefore, the formation of Ge 3+ component is the dominant key to achieve low D it for Ge gate stacks. Our work confirms that the same physical mechanism determines the Ge surface passivation by the GeO x regardless of the oxidation methods to grow the GeO x interfacial layer. As a result, to explore a growth process that can realize sufficient Ge 3+ component in the GeO x interlayer as thin as possible is important to achieve both equivalent oxide thickness scaling and superior interfacial property simultaneously. This conclusion is helpful to engineer the optimization of the Ge gate stacks.

  18. Recoil properties of antimony isotopes produced by the reaction of 570 MeV and 18.2 GeV protons with uranium

    CERN Document Server

    Hagebø, E

    1969-01-01

    Using the method of thick target and thick catchers, the ranges and other recoil properties of 13 (12) antimony isotopes between A = 115 and A = 131 (130) have been measured for the reaction of 570 MeV (18·2 GeV) protons with uranium. The kinetic energies T are almost independent of product mass number at 570 MeV but show a strong dependence at 18·2 GeV, the lightest isotopes having only about half the kinetic energy of the heavy ones. \\\\ \\\\The cascade deposition energies for production of antimony isotopes are almost equal at 570 MeV and 18·2 GeV and fit well to straight lines of the form E$^{∗}$ (A, Z) = E$^{∗}$ (A$_{0}$, Z) + b(A − A$_{0}$). Exceptions are the cascade deposition energies for $^{115}$Sb and $^{116}$Sb which seem to be somewhat too high at 18·2 GeV. By comparison with other work it seems that the slope $b$ of these lines is independent of product element, target and of proton irradiation energy above 450 MeV. \\\\ \\\\If we assume at 570 MeV, that the fissioning nucleus is a uranium ...

  19. Remote plasma enhanced chemical deposition of non-crystalline GeO2 on Ge and Si substrates.

    Science.gov (United States)

    Lucovsky, Gerald; Zeller, Daniel

    2011-09-01

    Non-crystalline GeO2 films remote were plasma deposited at 300 degrees C onto Ge substrates after a final rinse in NH4OH. The reactant precursors gas were: (i) down-stream injected 2% GeH4 in He as the Ge precursor, and (ii) up-stream, plasma excited O2-He mixtures as the O precursor. Films annealed at 400 degrees C displayed no evidence for loss of O resulting in Ge sub-oxide formation, and for a 5-6 eV mid-gap absorption associated with formation of GeOx suboxide bonding, x deposited on Ge and annealed at 600 degrees C and 700 degrees C display spectra indicative of loss of O-atoms, accompanied with a 5.5 eV absorption. X-ray absorption spectroscopy and many-electron theory are combined to describe symmetries and degeneracies for O-vacancy bonding defects. These include comparisons with remote plasma-deposited non-crystalline SiO2 on Si substrates with SiON interfacial layers. Three different properties of remote plasma GeO2 films are addressed comparisons between (i) conduction band and band edge states of GeO2 and SiO2, and (ii) electronic structure of O-atom vacancy defects in GeO2 and SiO2, and differences between (iii) annealing of GeO2 films on Ge substrates, and Si substrates passivated with SiON interfacial transition regions important for device applications.

  20. Search for Excited Leptons in $e^+ e^-$ Interactions at $\\sqrt{s}$=192 - 202 GeV

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; Duran, I.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Ewers, A.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kafer, D.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofiev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Roth, Stefan; Rosenbleck, C.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobyov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, An.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2001-01-01

    Excited leptons are searched for using the L3 detector at LEP. The data collected at centre-of-mass energies in the range from 192 up to 202 GeV correspond to a total luminosity of 233 $\\rm pb^{-1}$. No evidence of either pair production of excited leptons, nor of single production is found. From the searches for pair produced excited leptons, lower mass limits close to the kinematic limit are set. From the searches for singly produced excited leptons, upper limits on their couplings are derived in the mass range up to 200 GeV.

  1. Uptake of heavy metals by the marine algae Padina gymnospora from Sepetiba Bay (RJ, Brazil) through radiotracers

    International Nuclear Information System (INIS)

    Magalhaes, V.F. de.

    1991-01-01

    The accumulation and the loss of 210 Pb, 51 Cr and 65 Zn by the alga Padina gymnospora is studied through radiotracer experiments. The evaluation of the alga as a bio indicator of these heavy metals pollution is presented. The use of this seaweed species to study the transfer of Pb, Cr, and Zn through the food chain is discussed. (M.A.C.)

  2. Comparison of charged particle multiplicities in quark and gluon jets produced in e+e- annihilation at 29 GeV

    International Nuclear Information System (INIS)

    Derrick, M.; Gan, K.K.; Kooijman, P.; Loos, J.S.; Musgrave, B.; Price, L.E.; Schlereth, J.; Sugano, K.; Weiss, J.M.; Wood, D.E.; Blockus, D.; Brabson, B.; Gray, S.W.; Jung, C.; Neal, H.; Ogren, H.; Rust, D.R.; Valdata-Nappi, M.; Akerlof, C.; Bonvicini, G.; Chapman, J.; Errede, D.; Harnew, M.; Kesten, P.; Meyer, D.I.; Nitz, D.; Seidl, A.A.; Thun, R.; Trinko, T.; Willutzky, M.; Abachi, S.; Baringer, P.; Beltrami, I.; Bylsma, B.G.; Debonte, R.; Koltick, D.; Loeffler, F.J.; Low, E.H.; McIlwain, R.L.; Miller, D.H.; Ng, C.R.; Rangan, L.K.; Shibata, E.I.; Cork, B.

    1985-01-01

    The charged particle multiplicities of the quark and gluon jets in the three-fold symmetric e + e - ->qanti qg events at √s=29 GeV have been studied using the high resolution spectrometer at PEP. A value of sub(g)=6.7+-1.7+-1.0 for gluon jets with an energy of 9.7+-1.8 GeV is measured. The ratio, sub(g)/ sub(q), is 1.29sub(-0.41)sup(+0.21)+-0.20, which is significantly lower than the value of 9/4 naively expected from the ratio of the gluon-to-quark color charges. (orig./HSI)

  3. Development of new folate-based PET radiotracers: preclinical evaluation of 68Ga-DOTA-folate conjugates

    International Nuclear Information System (INIS)

    Fani, Melpomeni; Maecke, Helmut R.; Wang, Xuejuan; Nicolas, Guillaume; Medina, Christelle; Raynal, Isabelle; Port, Marc

    2011-01-01

    A number of 111 In- and 99m Tc-folate-based tracers have been evaluated as diagnostic agents for imaging folate receptor (FR)-positive tumours. A 68 Ga-folate-based radiopharmaceutical would be of great interest, combining the advantages of PET technology and the availability of 68 Ga from a generator. The aim of the study was to develop a new 68 Ga-folate-based PET radiotracer. Two new DOTA-folate conjugates, named P3026 and P1254, were synthesized using the 1,2-diaminoethane and 3-{2-[2-(3-amino-propoxy)-ethoxy]-ethoxy}-propylamine as a spacer, respectively. Both conjugates were labelled with 67/68 Ga. Binding affinity, internalization and externalization studies were performed using the FR-positive KB cell line. Biodistribution and PET/CT imaging studies were performed in nude mice, on a folate-deficient diet, bearing KB and HT1080 (FR-negative) tumours, concurrently. The new radiotracers were evaluated comparatively to the reference molecule 111 In-DTPA-folate ( 111 In-P3139). The K d values of 67/68 Ga-P3026 (4.65 ± 0.82 nM) and 67/68 Ga-P1254 (4.27 ± 0.42 nM) showed high affinity for the FR. The internalization rate followed the order 67/68 Ga-P3026 > 67/68 Ga-P1254 > 111 In-P3139, while almost double cellular retention was found for 67/68 Ga-P3026 and 67/68 Ga-P1254, compared to 111 In-P3139. The biodistribution data of 67/68 Ga-DOTA-folates showed high and receptor-mediated uptake on the FR-positive tumours and kidneys, with no significant differences compared to 111 In-P3139. PET/CT images, performed with 68 Ga-P3026, showed high uptake in the kidneys and clear visualization of the FR-positive tumours. The DOTA-folate conjugates can be efficiently labelled with 68 Ga in labelling yields and specific activities which allow clinical application. The characteristics of the 67/68 Ga-DOTA-folates are comparable to 111 In-DTPA-folate, which has already been used in clinical trials, showing that the new conjugates are promising candidates as PET radiotracers

  4. One-step Ge/Si epitaxial growth.

    Science.gov (United States)

    Wu, Hung-Chi; Lin, Bi-Hsuan; Chen, Huang-Chin; Chen, Po-Chin; Sheu, Hwo-Shuenn; Lin, I-Nan; Chiu, Hsin-Tien; Lee, Chi-Young

    2011-07-01

    Fabricating a low-cost virtual germanium (Ge) template by epitaxial growth of Ge films on silicon wafer with a Ge(x)Si(1-x) (0 deposition method in one step by decomposing a hazardousless GeO(2) powder under hydrogen atmosphere without ultra-high vacuum condition and then depositing in a low-temperature region. X-ray diffraction analysis shows that the Ge film with an epitaxial relationship is along the in-plane direction of Si. The successful growth of epitaxial Ge films on Si substrate demonstrates the feasibility of integrating various functional devices on the Ge/Si substrates.

  5. Sideward emission of produced particles in 22Ne and 28Si interactions with emulsion at 3.7 GeV/nucleon

    International Nuclear Information System (INIS)

    Salah, M.M.; El-Naghy, A.

    2000-01-01

    Analysis of emission of shower particles in 22 Ne + Ag(Br) collisions at 4.1 A GeV/c and in 28 Si + Ag(Br) interactions at 4.5 A GeV/c has been earned out to observe the side ward flow of nuclear matter . The transverse momentum method utilizing has been used to determine the reaction plane for the projectile fragments in an event. Data on side ward flow has been obtained by studying the azimuthal distribution of shower particles

  6. Abnormal gastrointestinal accumulation of radiotracer by gastric bleeding during 99mTc-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Chun, Kyung A.; Lee, Sang Woo; Lee, Jae Tae; Lee, Kyu Bo

    1998-01-01

    We present a case in which a patient with acute hemorrhagic gastritis demonstrated abnormal gastrointestinal accumulation of radiotracer during 99m Tc-methylene diphosphonate (MDP) skeletal scintigraphy. A hemorrhagic gastritis was subsequently demonstrated by endoscopy. The mechanism for the intestinal localization of 99m Tc-MDP in this patients is not clear, but we guess that the extravasated blood containing the radiopharmaceutical cannot recirculate and stays at the bleeding site, so we can see the intestinal activity

  7. Inhibition of enterovirus 71 (EV-71 infections by a novel antiviral peptide derived from EV-71 capsid protein VP1.

    Directory of Open Access Journals (Sweden)

    Chee Wah Tan

    Full Text Available Enterovirus 71 (EV-71 is the main causative agent of hand, foot and mouth disease (HFMD. In recent years, EV-71 infections were reported to cause high fatalities and severe neurological complications in Asia. Currently, no effective antiviral or vaccine is available to treat or prevent EV-71 infection. In this study, we have discovered a synthetic peptide which could be developed as a potential antiviral for inhibition of EV-71. Ninety five synthetic peptides (15-mers overlapping the entire EV-71 capsid protein, VP1, were chemically synthesized and tested for antiviral properties against EV-71 in human Rhabdomyosarcoma (RD cells. One peptide, SP40, was found to significantly reduce cytopathic effects of all representative EV-71 strains from genotypes A, B and C tested, with IC(50 values ranging from 6-9.3 µM in RD cells. The in vitro inhibitory effect of SP40 exhibited a dose dependent concentration corresponding to a decrease in infectious viral particles, total viral RNA and the levels of VP1 protein. The antiviral activity of SP40 peptide was not restricted to a specific cell line as inhibition of EV-71 was observed in RD, HeLa, HT-29 and Vero cells. Besides inhibition of EV-71, it also had antiviral activities against CV-A16 and poliovirus type 1 in cell culture. Mechanism of action studies suggested that the SP40 peptide was not virucidal but was able to block viral attachment to the RD cells. Substitutions of arginine and lysine residues with alanine in the SP40 peptide at positions R3A, R4A, K5A and R13A were found to significantly decrease antiviral activities, implying the importance of positively charged amino acids for the antiviral activities. The data demonstrated the potential and feasibility of SP40 as a broad spectrum antiviral agent against EV-71.

  8. Interfacial sharpness and intermixing in a Ge-SiGe multiple quantum well structure

    Science.gov (United States)

    Bashir, A.; Gallacher, K.; Millar, R. W.; Paul, D. J.; Ballabio, A.; Frigerio, J.; Isella, G.; Kriegner, D.; Ortolani, M.; Barthel, J.; MacLaren, I.

    2018-01-01

    A Ge-SiGe multiple quantum well structure created by low energy plasma enhanced chemical vapour deposition, with nominal well thickness of 5.4 nm separated by 3.6 nm SiGe spacers, is analysed quantitatively using scanning transmission electron microscopy. Both high angle annular dark field imaging and electron energy loss spectroscopy show that the interfaces are not completely sharp, suggesting that there is some intermixing of Si and Ge at each interface. Two methods are compared for the quantification of the spectroscopy datasets: a self-consistent approach that calculates binary substitutional trends without requiring experimental or computational k-factors from elsewhere and a standards-based cross sectional calculation. Whilst the cross section approach is shown to be ultimately more reliable, the self-consistent approach provides surprisingly good results. It is found that the Ge quantum wells are actually about 95% Ge and that the spacers, whilst apparently peaking at about 35% Si, contain significant interdiffused Ge at each side. This result is shown to be not just an artefact of electron beam spreading in the sample, but mostly arising from a real chemical interdiffusion resulting from the growth. Similar results are found by use of X-ray diffraction from a similar area of the sample. Putting the results together suggests a real interdiffusion with a standard deviation of about 0.87 nm, or put another way—a true width defined from 10%-90% of the compositional gradient of about 2.9 nm. This suggests an intrinsic limit on how sharp such interfaces can be grown by this method and, whilst 95% Ge quantum wells (QWs) still behave well enough to have good properties, any attempt to grow thinner QWs would require modifications to the growth procedure to reduce this interdiffusion, in order to maintain a composition of ≥95% Ge.

  9. Metastability and relaxation in tensile SiGe on Ge(001) virtual substrates

    International Nuclear Information System (INIS)

    Frigerio, Jacopo; Lodari, Mario; Chrastina, Daniel; Mondiali, Valeria; Isella, Giovanni; Bollani, Monica

    2014-01-01

    We systematically study the heteroepitaxy of SiGe alloys on Ge virtual substrates in order to understand strain relaxation processes and maximize the tensile strain in the SiGe layer. The degree of relaxation is measured by high-resolution x-ray diffraction, and surface morphology is characterized by atomic force microscopy. The results are analyzed in terms of a numerical model, which considers dislocation nucleation, multiplication, thermally activated glide, and strain-dependent blocking. Relaxation is found to be sensitive to growth rate and substrate temperature as well as epilayer misfit and thickness, and growth parameters are found which allow a SiGe film with over 4 GPa of tensile stress to be obtained.

  10. Thermal transport property of Ge34 and d-Ge investigated by molecular dynamics and the Slack's equation

    International Nuclear Information System (INIS)

    Han-Fu, Wang; Wei-Guo, Chu; Yan-Jun, Guo; Hao, Jin

    2010-01-01

    In this study, we evaluate the values of lattice thermal conductivity κ L of type II Ge clathrate (Ge 34 ) and diamond phase Ge crystal (d-Ge) with the equilibrium molecular dynamics (EMD) method and the Slack's equation. The key parameters of the Slack's equation are derived from the thermodynamic properties obtained from the lattice dynamics (LD) calculations. The empirical Tersoff's potential is used in both EMD and LD simulations. The thermal conductivities of d-Ge calculated by both methods are in accordance with the experimental values. The predictions of the Slack's equation are consistent with the EMD results above 250 K for both Ge 34 and d-Ge. In a temperature range of 200–1000 K, the κ L value of d-Ge is about several times larger than that of Ge 34 . (condensed matter: structure, thermal and mechanical properties)

  11. Helium/solid powder O-ring leakage correlation experiments using a radiotracer

    International Nuclear Information System (INIS)

    Bild, R.W.; Leisher, W.B.; Weissman, S.H.; Seya, M.

    1984-01-01

    UO 2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

  12. Inclusive prompt muon and dimuon production by 28.5 GeV protons

    International Nuclear Information System (INIS)

    Grannan, D.M.

    1978-01-01

    The inclusive production of single prompt muons and muon pairs from the interaction of 28.5 GeV protons with nuclear targets has been investigated at Brookhaven National Laboratory. The ratio of single prompt muons to mesons produced in the fragmentation region was compared with data at 400 GeV and found to be independent of the proton energy. The dimuon differential cross section dsigma/dx was observed to be equal within errors to that observed at 150 GeV and 400 GeV incident proton energies. The average invariant mass of the dimuons increased with x to a mean mass of about 700 MeV/c 2 at x = 0.56. Measurements of the intensity of muon pairs generated in Wolfram, iron, and carbon targets established the A-dependence of the production. The dimuon production was found to vary with the target nucleous as A/sup 2/3/ in an x-region where meson production varies as A 0 54 . A high resolution measurement of the low mass dimuon spectrum yielded a continuum similar to that observed at 150 GeV, demonstrating the scaling of the differential cross section dsigma/dxdM in dimuon production

  13. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  14. Characterizing root activity of guava trees by radiotracer technique

    International Nuclear Information System (INIS)

    Purohit, A.G.; Mukherjee, S.K.

    1974-01-01

    The distribution pattern of root activity of 12-year-old trees of guava (Psidium guajava L.) was determined by radiotracer technique. 32 P soloution was injected into the soil at lateral distances of 120, 240 and 360 cm from the tree trunk at depths of 15,30,60 and 90 cm. The 32 P uptake by the tree was determined by leaf analysis. In the rainy season the root activity or 32 P uptake was greater near the soil surface and midway between the trunk and the drip-line. The root activity decreased with an increase in the depth and distance from trunk. These results compared well with the actual distribution of feeder roots as determined by the soil-auger method. In summer the roots near the surface become less active in 32 P absorption with a drcrease in surface soil moisture. A decrease in the root activity in the surface soil was accompanied by an increase in 32 P uptake from lower depths. (author)

  15. Further evidences for enhanced nuclear cross-sections observed in 44 GeV carbon ion interactions with copper

    International Nuclear Information System (INIS)

    Brandt, R.; Abdullaev, I.G.; Adloff, J.C.

    1995-01-01

    The work of enhanced nuclear cross-sections of secondary fragments produced in the interaction of 44 GeV 12 C with copper has been deepened and extended. The earlier experiment on the emission of secondary fragments into large angles producing enhanced amounts of 24 Na in copper (Phys. Rev. C, 45, 1194(1992)) was confirmed and refined both experimentally and theoretically. In this context, one looked for another signature of such enhanced production, namely for enhanced neutron production. In order to search for this, a 20 cm thick massive copper target was irradiated with 18 and 44 GeV 12 C-ions. Secondary fragments already described could interact again with copper. Outside the metallic target, secondary neutrons got moderated and low energy nuclear reactions were studied in La and U radiochemically via (n,γ)-reactions and also with various solid state nuclear track detectors. One observed an indication, however not yet significant, of enhanced production rates for low energy nuclear reactions only with 44 GeV 12 C, when compared to 18 GeV 12 C-ions. Besides some proton irradiations at SATURNE, Saclay (France) at 2.6 GeV and at PSI, Villigen (Switzerland) at 0.6 GeV all other irradiations were carried out at the Synchrophasotron, LHE, JINR, Dubna (Russia). 46 refs., 14 figs., 8 tabs

  16. Study of the interactions of 13.8 GeV/c protons with the heavy nuclei of the emulsions exposed in magnetic fuel of 170 kgauss; Estudio de las interacciones de protones de 13,8 geV/c con los nucleos pesados de emusiones

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Aleixandre, J L

    1967-07-01

    145 stars with N{sub h}>8 produced by the interactions of 13.8 GeV/c protons with Ag and Br nuclei have been analysed. The emulsion stack was irradiated in a 170 K gauss magnetic field. Statistical results concerning the main characteristics of the different particles emitted are given and the energy balance is evaluated. The main features of both 24 GeV/c protons and 17 GeV/c {pi}- interactions are compared with those we have found for 13.8 GeV/c protons interactions. (Author) 27 refs.

  17. Control of Ge1-x-ySixSny layer lattice constant for energy band alignment in Ge1-xSnx/Ge1-x-ySixSny heterostructures

    Science.gov (United States)

    Fukuda, Masahiro; Watanabe, Kazuhiro; Sakashita, Mitsuo; Kurosawa, Masashi; Nakatsuka, Osamu; Zaima, Shigeaki

    2017-10-01

    The energy band alignment of Ge1-xSnx/Ge1-x-ySixSny heterostructures was investigated, and control of the valence band offset at the Ge1-xSnx/Ge1-x-ySixSny heterointerface was achieved by controlling the Si and Sn contents in the Ge1-x-ySixSny layer. The valence band offset in the Ge0.902Sn0.098/Ge0.41Si0.50Sn0.09 heterostructure was evaluated to be as high as 330 meV, and its conduction band offset was estimated to be 150 meV by considering the energy bandgap calculated from the theoretical prediction. In addition, the formation of the strain-relaxed Ge1-x-ySixSny layer was examined and the crystalline structure was characterized. The epitaxial growth of a strain-relaxed Ge0.64Si0.21Sn0.15 layer with the degree of strain relaxation of 55% was examined using a virtual Ge substrate. Moreover, enhancement of the strain relaxation was demonstrated by post-deposition annealing, where a degree of strain relaxation of 70% was achieved after annealing at 400 °C. These results indicate the possibility for enhancing the indirect-direct crossover with a strained and high-Sn-content Ge1-xSnx layer on a strain-relaxed Ge1-x-ySixSny layer, realizing preferable carrier confinement by type-I energy band alignment with high conduction and valence band offsets.

  18. Conceptual design of the Argonne 6-GeV synchrotron light source

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.; Khoe, T.

    1985-01-01

    The Argonne National Laboratory Synchrotron Light Source Storage Ring is designed to have a natural emittance of 6.5 X 10 -9 m for circulating 6-GeV positrons. Thirty of the 32 long straight sections, each 6.5-m long, will be available for synchrotron light insertion devices. A circulating positron current of 300 mA can be injected in about 8 min. from a booster synchrotron operating with a repetition time of 1.2 sec. The booster synchrotron will contain two different rf systems. The lower frequency system (38.97 MHz) will accept positrons from a 360-MeV linac and will accelerate them to 2.25 GeV. The higher frequency system (350.76 MHz) will accelerate the positrons to 6 GeV. The positrons will be produced from a 300-MeV electron beam on a tungsten target

  19. Structural Analyses of Phase Stability in Amorphous and Partially Crystallized Ge-Rich GeTe Films Prepared by Atomic Layer Deposition.

    Science.gov (United States)

    Gwon, Taehong; Mohamed, Ahmed Yousef; Yoo, Chanyoung; Park, Eui-Sang; Kim, Sanggyun; Yoo, Sijung; Lee, Han-Koo; Cho, Deok-Yong; Hwang, Cheol Seong

    2017-11-29

    The local bonding structures of Ge x Te 1-x (x = 0.5, 0.6, and 0.7) films prepared through atomic layer deposition (ALD) with Ge(N(Si(CH 3 ) 3 ) 2 ) 2 and ((CH 3 ) 3 Si) 2 Te precursors were investigated using Ge K-edge X-ray absorption spectroscopy (XAS). The results of the X-ray absorption fine structure analyses show that for all of the compositions, the as-grown films were amorphous with a tetrahedral Ge coordination of a mixture of Ge-Te and Ge-Ge bonds but without any signature of Ge-GeTe decomposition. The compositional evolution in the valence band electronic structures probed through X-ray photoelectron spectroscopy suggests a substantial chemical influence of additional Ge on the nonstoichiometric GeTe. This implies that the ALD process can stabilize Ge-abundant bonding networks like -Te-Ge-Ge-Te- in amorphous GeTe. Meanwhile, the XAS results on the Ge-rich films that had undergone post-deposition annealing at 350 °C show that the parts of the crystalline Ge-rich GeTe became separated into Ge crystallites and rhombohedral GeTe in accordance with the bulk phase diagram, whereas the disordered GeTe domains still remained, consistent with the observations of transmission electron microscopy and Raman spectroscopy. Therefore, amorphousness in GeTe may be essential for the nonsegregated Ge-rich phases and the low growth temperature of the ALD enables the achievement of the structurally metastable phases.

  20. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Shenoy, K T; Sreenivas, T

    2015-03-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40-60MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Electrically detected magnetic resonance study of the Ge dangling bonds at the Ge(1 1 1)/GeO2 interface after capping with Al2O3 layer

    International Nuclear Information System (INIS)

    Paleari, S.; Molle, A.; Accetta, F.; Lamperti, A.; Cianci, E.; Fanciulli, M.

    2014-01-01

    The electrical activity of Ge dangling bonds is investigated at the interface between GeO 2 -passivated Ge(1 1 1) substrate and Al 2 O 3 grown by atomic layer deposition, by means of electrically detected magnetic resonance spectroscopy (EDMR). The Al 2 O 3 /GeO 2 /Ge stacked structure is promising as a mobility booster for the post-Si future electronic devices. EDMR proved to be useful in characterizing interface defects, even at the very low concentrations of state-of-the-art devices ( 10 cm −2 ). In particular, it is shown that capping the GeO 2 -passivated Ge(1 1 1) with Al 2 O 3 has no impact on the microstructure of the Ge dangling bond.

  2. Dynamic PET scanning and compartmental model analysis to determine cellular level radiotracer distribution in vivo

    International Nuclear Information System (INIS)

    Smith, G.T.; Hubner, K.F.; Goodman, M.M.; Stubbs, J.B.

    1992-01-01

    Positron emission tomography (PET) has been used to measure tissue radiotracer concentration in vivo. Radiochemical distribution can be determined with compartmental model analysis. A two compartment model describes the kinetics of N-13 ammonia ( 13 NH 3 ) in the myocardium. The model consists of a vascular space, Q 1 and a space for 13 NH 3 bound within the tissue, Q 2 . Differential equations for the model can be written: X(t) = AX(t) + BU( t), Y(t)= CX(t)+ DU(t) (1) where X(t) is a column vector [Q 1 (t); Q 2 (t)], U(t) is the arterial input activity measured from the left ventricular blood pool, and Y(t) is the measured tissue activity using PET. Matrices A, B, C, and D are dependent on physiological parameters describing the kinetics of 13 NH 3 in the myocardium. Estimated parameter matrices in Equation 1 have been validated in dog experiments by measuring myocardial perfusion with dynamic PET scanning and intravenous injection of 13 NH 3 . Tracer concentrations for each compartment can be calculated by direct integration of Equation 1. If the cellular level distribution of each compartment is known, the concentration of tracer within the intracellular and extracellular space can be determined. Applications of this type of modeling include parameter estimation for measurement of physiological processes, organ level dosimetry, and determination of cellular radiotracer distribution

  3. Novel in situ radiotracer methods for the direct and indirect study of chromate adsorption on alumina

    International Nuclear Information System (INIS)

    Gancs, L.; Nemeth, Z.; Horanyi, G.

    2002-01-01

    Radiotracer methods, particularly the radiotracer thin foil method, provide unique possibility of in situ monitoring of chromate adsorption on powdered adsorbents. Two different versions of the thin foil method can be distinguished. In the direct method, the species to be studied is labelled and the radiation measured gives direct information on the adsorption of this species. In the indirect method, a different labelled indicator species is added to the system and the adsorption of this species is followed and the adsorption of the species to be studied is determined based on analysis of the competitive adsorption processes. Both methods were used in the present study. In the in situ methods, the radiation measured consists of two main parts, one coming from the solution background, the other originating from the adsorption layer. In the case of the thin foil method using isotopes emitting soft β - radiation or low energy X-ray the solution background is governed and minimised by self-absorption of the radiation. In the direct study we applied an experimental methodology based on the energy selective measurement of the characteristic K α,β X-radiation emitted by the 51 Cr-labelled chromate species, whereas 35 S-labelled sulphate ions were used as the indicator species in the indirect study. (P.A.)

  4. Mn-doped Ge self-assembled quantum dots via dewetting of thin films

    Energy Technology Data Exchange (ETDEWEB)

    Aouassa, Mansour, E-mail: mansour.aouassa@yahoo.fr [LMON, Faculté des Sciences de Monastir, Avenue de l’environnement Monastir 5019 (Tunisia); Jadli, Imen [LMON, Faculté des Sciences de Monastir, Avenue de l’environnement Monastir 5019 (Tunisia); Bandyopadhyay, Anup [Department of Mechanical Engineering, Texas A& M University, College Station, TX 77843 (United States); Kim, Sung Kyu [Center for Nanomaterials and Chemical Reactions, Institute for Basic Science (IBS), Yuseong-daero 1689-gil, Yuseong-gu, Daejeon (Korea, Republic of); Department of Materials Science and Engineering, KAIST 291 Daehak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Karaman, Ibrahim [Department of Mechanical Engineering, Texas A& M University, College Station, TX 77843 (United States); Lee, Jeong Yong [Center for Nanomaterials and Chemical Reactions, Institute for Basic Science (IBS), Yuseong-daero 1689-gil, Yuseong-gu, Daejeon (Korea, Republic of); Department of Materials Science and Engineering, KAIST 291 Daehak-ro, Yuseong-gu, Daejeon (Korea, Republic of)

    2017-03-01

    Highlights: • We report the new fabrication approach for producing a self- assembled Mn dpoed Ge quantum dots (QDs) on SiO{sub 2} thin film with a Curie temperature above room temperature. These magnetic QDs are crystalline, monodisperse and have a well-defined shape and a controlled size. The investigation opens new routes for elaboration of self-assembled magnetic nanocrystals - Abstract: In this study, we demonstrate an original elaboration route for producing a Mn-doped Ge self-assembled quantum dots on SiO{sub 2} thin layer for MOS structure. These magnetic quantum dots are elaborated using dewetting phenomenon at solid state by Ultra-High Vacuum (UHV) annealing at high temperature of an amorphous Ge:Mn (Mn: 40%) nanolayer deposed at very low temperature by high-precision Solid Source Molecular Beam Epitaxy on SiO{sub 2} thin film. The size of quantum dots is controlled with nanometer scale precision by varying the nominal thickness of amorphous film initially deposed. The magnetic properties of the quantum-dots layer have been investigated by superconducting quantum interference device (SQUID) magnetometry. Atomic force microscopy (AFM), x-ray energy dispersive spectroscopy (XEDS) and transmission electron microscopy (TEM) were used to examine the nanostructure of these materials. Obtained results indicate that GeMn QDs are crystalline, monodisperse and exhibit a ferromagnetic behavior with a Curie temperature (TC) above room temperature. They could be integrated into spintronic technology.

  5. Optimization of Si–C reaction temperature and Ge thickness in C-mediated Ge dot formation

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Yuhki, E-mail: yu-ki@ecei.tohoku.ac.jp; Itoh, Yuhki; Kawashima, Tomoyuki; Washio, Katsuyoshi

    2016-03-01

    To form Ge dots on a Si substrate, the effect of thermal reaction temperature of sub-monolayer C with Si (100) was investigated and the deposited Ge thickness was optimized. The samples were prepared by solid-source molecular beam epitaxy with an electron-beam gun for C sublimation and a Knudsen cell for Ge evaporation. C of 0.25 ML was deposited on Si (100) at a substrate temperature of 200 °C, followed by a high-temperature treatment at the reaction temperature (T{sub R}) of 650–1000 °C to create Si–C bonds. Ge equivalent to 2 to 5 nm thick was subsequently deposited at 550 °C. Small and dense dots were obtained for T{sub R} = 750 °C but the dot density decreased and the dot diameter varied widely in the case of lower and higher T{sub R}. A dot density of about 2 × 10{sup 10} cm{sup −2} was achieved for Ge deposition equivalent to 3 to 5 nm thick and a standard deviation of dot diameter was the lowest of 10 nm for 5 nm thick Ge. These results mean that C-mediated Ge dot formation was strongly influenced not only by the c(4 × 4) reconstruction condition through the Si–C reaction but also the relationship between the Ge deposition thickness and the exposed Si (100)-(2 × 1) surface area. - Highlights: • The effect of Si–C reaction temperature on Ge dot formation was investigated. • Small and dense dots were obtained for T{sub R} = 750 °C. • The dot density of about 2 × 10{sup 10} cm{sup −2} was achieved for Ge = 3 to 5 nm. • The standard deviation of dot diameter was the lowest of 10 nm at Ge = 5 nm.

  6. Radiotracer techniques in mineral processing

    International Nuclear Information System (INIS)

    Przewlocki, K.

    1991-01-01

    The value of the smelter metal content in currently exploited polymetallic ores mostly does not exceed 2%. Before metallurgical treatment, ore must pass through the concentration process. The benefication process usually starts from the comminution of excavated material and terminates at the flotation and drying of the concentrate. These operations consume vast quantities of energy. To be economically justified, the process requires optimization and, if possible, automatic control. Radioactive tracers were found to be useful in the identification of particular technological subsystems and their subsequent optimization. A great deal of experience has been gathered in this field so far. The industrial radiotracer test (RTT) is carried out using very sensitive multidetector recording systems which have digital data acquisition capabilities. The optimization strategy consists of periodically adjusting technological process and set points of controlled variables according to certain improvement procedures. If computer facilities are available, data interpretation and calibration of the mathematical models describing the technical process itself can be performed on the spot. This significantly accelerates the whole procedure as RTT may be repeated for particular system configurations. The procedure of plant optimization by means of RTT is illustrated in the paper using the example of the copper ore enrichment process, assuming that it is representative of the whole mineral industry. Identification by RTT of the three main operations involved in the ore enrichment process, such as comminution, flotation and granular classification, is discussed in detail as particular case studies. In reference to this, it is also shown how the technological process can be adjusted to be most efficient. (author). 14 refs, 7 figs

  7. Fast-neutron-induced potential background near the Q value of neutrinoless double-β decay of 76Ge

    Science.gov (United States)

    Tornow, W.; Bhike, Megha; Fallin, B.; Krishichayan

    2016-01-01

    The 76Ge (n,p)76Ga reaction and the subsequent β decay of 76Ga to 76Ge has been used to excite the 3951.89-keV state of 76Ge , which decays by the emission of a 2040.70-keV γ ray. Using high-purity germanium detectors, the associated pulse-height signal may be undistinguishable from the potential signal produced in neutrinoless double-β decay of 76Ge with its Q value of 2039.0 keV. At 20-MeV neutron energy the production cross section of the 2040.70-keV γ ray is approximately 0.1 mb.

  8. Nuclear interactions of 400 GeV protons in emulsion

    International Nuclear Information System (INIS)

    Otterlund, I.; Stenlund, E.; Andersson, B.

    1978-04-01

    We report on 400 GeV proton-emulsion nucleus reactions and compare the results to hadron-nucleus reactions at smaller energies. In particular we present results on the emission of fast target protons (essentially grey track particles) and on their correlation with the number of collisions inside the nucleus, ν, with the number of charged evaporated particles (essentially black particles) and with the number of pions produced (essentially shower particles). We observe that the main features of the 200-400 GeV data are very similar. However, we find that the mean shower-particle multiplicity at 400 GeV is essentially higher than expected from the simple independent particle model prediction = [1 + 0.5 ( - 1)]. The shower particle multiplicities do not seem to follow a target mass dependence of the form = A sup(α) with α = 0.19 as has been suggested in the literature. The pseudo-rapidity distribution shows limiting target and projectile fragmentation. The shower particle multiplicity in the ''central region'' increases linearily with but faster than 0.5 times the corresponding multiplicity in pp-reactions. (author)

  9. Nuclear interactions of 400 GeV protons in emulsion

    International Nuclear Information System (INIS)

    Otterlund, I.; Stenlund, E.; Andersson, B.

    1978-04-01

    We report on 400 GeV proton-emulsion nucleus reactions and compare the results to hadron-nucleus reactions at smaller energies. In particular we present results on the emission of fast target protons (essentially grey track particles) and on their correlation with the number of collisions inside the nucleus, ν, with the number of charged evaporated particles (essentially black track particles) and with the number of pions produced (essentially shower particles). We observe that the main features of the 200-400 GeV data are very similar. However, we find that the mean shower-particle multiplicity at 400 GeV is essentially higher than expected from the simple independent particle model prediction = [1 + 0.5 ( - 1)]. The shower particle multiplicities do not seem to follow a target mass dependence of the form = Asup(α) with α = 0.14 or α = 0.19 as has been suggested in the literature. The pseudo-rapidity distribution shows limiting target and projectile fragmentation. The shower particle multiplicity in the ''central region'' increases linearily with but faster than 0.5 times the corresponding multiplicity in pp-reactions. (author)

  10. Fabrication of Ge-on-insulator wafers by Smart-CutTM with thermal management for undamaged donor Ge wafers

    Science.gov (United States)

    Kim, Munho; Cho, Sang June; Jayeshbhai Dave, Yash; Mi, Hongyi; Mikael, Solomon; Seo, Jung-Hun; Yoon, Jung U.; Ma, Zhenqiang

    2018-01-01

    Newly engineered substrates consisting of semiconductor-on-insulator are gaining much attention as starting materials for the subsequent transfer of semiconductor nanomembranes via selective etching of the insulating layer. Germanium-on-insulator (GeOI) substrates are critically important because of the versatile applications of Ge nanomembranes (Ge NMs) toward electronic and optoelectronic devices. Among various fabrication techniques, the Smart-CutTM technique is more attractive than other methods because a high temperature annealing process can be avoided. Another advantage of Smart-CutTM is the reusability of the donor Ge wafer. However, it is very difficult to realize an undamaged Ge wafer because there exists a large mismatch in the coefficient of thermal expansion among the layers. Although an undamaged donor Ge wafer is a prerequisite for its reuse, research related to this issue has not yet been reported. Here we report the fabrication of 4-inch GeOI substrates using the direct wafer bonding and Smart-CutTM process with a low thermal budget. In addition, a thermo-mechanical simulation of GeOI was performed by COMSOL to analyze induced thermal stress in each layer of GeOI. Crack-free donor Ge wafers were obtained by annealing at 250 °C for 10 h. Raman spectroscopy and x-ray diffraction (XRD) indicated similarly favorable crystalline quality of the Ge layer in GeOI compared to that of bulk Ge. In addition, Ge p-n diodes using transferred Ge NM indicate a clear rectifying behavior with an on and off current ratio of 500 at ±1 V. This demonstration offers great promise for high performance transferrable Ge NM-based device applications.

  11. The gastroesophageal (GE) scintiscan in detection of GE reflux and pulmonary aspiration in children

    International Nuclear Information System (INIS)

    Arasu, T.S.; Franken, E.A.; Wyllie, R.; Eigen, H.; Grosfeld, J.L.; Siddiqui, A.R.; Fitzgerald, J.F.

    1980-01-01

    Gastroesophageal scintiscans and barium examinations were performed on 30 children with documented GE reflux and 13 control patients. After instillation of 2 mCi of Tc99m sulfur colloid into the stomach, serial images of the abdomen and thorax were obtained. The GE scintiscan was positive in 17 of 30 with GE reflux; the barium study was positive in 15 of 30. A positive scintiscan and/or barium study was found in 21 of 30 patients with reflux, and none of the controls. Pulmonay aspiration of gastric contents was not detected by either method. We conclude that the GE scintiscan is complementary to barium studies in the diagnosis of GE reflux, and neither study approaches the accuracy of more sophisticated tests [fr

  12. Self-Ordered Voids Formation in SiO2 Matrix by Ge Outdiffusion

    Directory of Open Access Journals (Sweden)

    B. Pivac

    2018-01-01

    Full Text Available The annealing behavior of very thin SiO2/Ge multilayers deposited on Si substrate by e-gun deposition in high vacuum was explored. It is shown that, after annealing at moderate temperatures (800°C in inert atmosphere, Ge is completely outdiffused from the SiO2 matrix leaving small (about 3 nm spherical voids embedded in the SiO2 matrix. These voids are very well correlated and formed at distances governed by the preexisting multilayer structure (in vertical direction and self-organization (in horizontal direction. The formed films produce intensive photoluminescence (PL with a peak at 500 nm. The explored dynamics of the PL decay show the existence of a very rapid process similar to the one found at Ge/SiO2 defected interface layers.

  13. Charged hadron composition of the final state in e+e- annihilation up to 1.9 GeV/c at E/sub cm/ = 29 GeV

    International Nuclear Information System (INIS)

    Ong, P.P.

    1983-08-01

    The momentum distributions of hadrons produced in e+e - collisions at a center of mass energy of 29 GeV have been measured. The data used in this analysis were collected by the High Resolution Spectrometer (HRS) at the Positron Electron Project (PEP) in the Spring of 1982. The HRS is a general purpose particle detector consisting of a 16.2 kgauss solenoidal magnet, 17 layers of tracking chambers and multiple layers of lead-scintillator shower counters. The data consist of 8,200 hadronic events, corresponding to an integrated luminosity of 19.6 pbarn -1 at E/sub cm/ = 29 GeV. Using the barrel shower counters' time-of-flight (TOF) measurements, charged particles in the momentum range 0.5 - 1.9 GeV/c are separated statistically. Measurements of differential cross sections, d sigma /dp, scaled cross sections, S*(dsigma/dXp), and charged particle fractions are presented and compared with measurements made by the TASSO and the JADE groups

  14. 7 CFR 1005.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ... value at the uniform prices for skim milk and butterfat, adjusted for plant location, of the handler's receipts of producer milk; and the value at the uniform price, as adjusted pursuant to § 1005.75...

  15. 7 CFR 1006.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ... value at the uniform prices for skim milk and butterfat, adjusted for plant location, of the handler's receipts of producer milk; and the value at the uniform price, as adjusted pursuant to § 1006.75...

  16. 7 CFR 1131.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ... of: (1) The value at the uniform prices for skim milk and butterfat, adjusted for plant location, of the handler's receipts of producer milk; and (2) The value at the uniform price as adjusted pursuant...

  17. 7 CFR 1007.71 - Payments to the producer-settlement fund.

    Science.gov (United States)

    2010-01-01

    ... value at the uniform prices for skim milk and butterfat, adjusted for plant location, of the handler's receipts of producer milk; and the value at the uniform price, as adjusted pursuant to § 1007.75...

  18. Application of radiotracers in the assessment of prophylactic role of zinc in experimental model of colon carcinogenesis

    International Nuclear Information System (INIS)

    Dani, Vijayata; Vaiphei, K.; Dhawan, D.K.

    2010-01-01

    Full text: The present study elucidated the modulatory effects of zinc in 1,2 dimethylhydrazine (DMH) induced colon carcinogenesis using radiotracer techniques. Rats were segregated into four groups viz., untreated control, DMH treated, zinc treated, DMH+zinc treated. Colon carcinogenesis was induced through weekly subcutaneous injections of DMH (30 mg/Kg body weight) for 16 weeks. Zinc was supplemented to rats at a dose level of 227mg/L in drinking water, ad libitum. The prophylactic role of zinc was assessed by following radiotracer techniques viz: whole body biological half life of 65 Zn and 65 Zn biodistribution, subcellular distribution, uptake of 3 H-Thymidine to assess rate of DNA synthesis, radiorespirometric determination of 14 C-D-Glucose metabolism and in-vitro uptake of labeled aminoacids. The statistical significance of the data has been determined by using one way analysis of variance (ANOVA) followed by multiple post - hoc test. The carcinogenic state in the animals was confirmed by histopathological examination, whereby, well-differentiated signs of dysplasia were evident in colonic tissue sections of DMH treated rats. The biokinetics study of zinc revealed a significant decrease in the biological half life of 65 Zn. Also, DMH treatment caused a significant increase in the percent uptake values of 65 Zn in the colon, small intestine, kidney and blood, whereas a significant decrease was observed in the liver. The uptake rates of amino acids viz: 14 C-glycine, 14 C-alanine and 14 C-lysine were significantly higher in the DMH treated colons. Moreover, a significant increase in the uptake and turnover of 14 C-D-Glucose was also observed after DMH treatment. A significant increase in the ( 3 H)-thymidine uptake was observed following 16 weeks DMH treatment. However, supplementation of zinc significantly reversed the proliferative effect of DMH as evidenced by ameliorating the altered parameters. Radiotracer techniques play an important role in assessing

  19. Fragment production in 12-GeV proton-induced reactions

    International Nuclear Information System (INIS)

    Hirata, Yuichi; Ohnishi, Akira; Ohtsuka, Naohiko; Nara, Yasushi; Niida, Koji; Chiba, Satoshi; Takada, Hiroshi

    2000-01-01

    We study mass and angular distribution of Intermediate Mass Fragment (IMF) produced from p(12 GeV)+ 197 Au reaction by using JAM cascade model combined with percolation model. Although the mass distribution of IMF is well reproduced, the experimentally observed sideward peak of IMF angular distribution is not explained within present JAM + percolation model. (author)

  20. GeNF - Experimental report 2006

    International Nuclear Information System (INIS)

    Pranzas, P.K.; Schreyer, A.; Willumeit, R.

    2007-01-01

    At the Geesthacht Neutron Facility GeNF about 212 experiments were performed in 2006 by GKSS and by or for external users, partners or contractors. In most cases the measurements were performed and analysed in cooperation by the guests and by the GKSS staff or by the permanent external user group staff. The activities, which are based on a proposal procedure and on the in house R and D program, are reported in 71 contributions in the present annual experimental report for the year 2006. The contributions may contain one or also several combined experiments. During 2006 the GKSS research reactor FRG-1 achieved an operation time of 197 days at the full 5 MW reactor power providing a neutron flux of ca. 1.4 x 10 14 thermal neutrons/cm 2 s. The cold neutron source was available during the complete operation time. The focus of the in house R and D work at GeNF instruments was the characterisation of nanostructures in engineering materials, the analysis of stresses and textures in welds and technical structures at ARES-2, TEX-2, DCD and SANS-2, the structural investigation of hydrogen containing substances such as polymers, colloids and biological macromolecules at SANS-1 as well as the characterisation of magnetic thin films at PNR, NeRo, POLDI and ROeDI. The thoroughly upgraded residual stress diffractomer ARES-2 went in full operation in spring 2006 as well as the new neutron tomography device at GENRA-3. The installation of modern experiment control hardware and software based on LabView was completed on all designated instruments. In the appendices I and II the experimental reports of REFSANS at FRM II are attached as well as of the GKSS outstation HARWI-II at DESY. Both instruments started full operation in 2006. (orig.)

  1. GeNF - Experimental report 2006

    Energy Technology Data Exchange (ETDEWEB)

    Pranzas, P K; Schreyer, A; Willumeit, R [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. of Materials Research

    2007-07-01

    At the Geesthacht Neutron Facility GeNF about 212 experiments were performed in 2006 by GKSS and by or for external users, partners or contractors. In most cases the measurements were performed and analysed in cooperation by the guests and by the GKSS staff or by the permanent external user group staff. The activities, which are based on a proposal procedure and on the in house R and D program, are reported in 71 contributions in the present annual experimental report for the year 2006. The contributions may contain one or also several combined experiments. During 2006 the GKSS research reactor FRG-1 achieved an operation time of 197 days at the full 5 MW reactor power providing a neutron flux of ca. 1.4 x 10{sup 14} thermal neutrons/cm{sup 2}s. The cold neutron source was available during the complete operation time. The focus of the in house R and D work at GeNF instruments was the characterisation of nanostructures in engineering materials, the analysis of stresses and textures in welds and technical structures at ARES-2, TEX-2, DCD and SANS-2, the structural investigation of hydrogen containing substances such as polymers, colloids and biological macromolecules at SANS-1 as well as the characterisation of magnetic thin films at PNR, NeRo, POLDI and ROeDI. The thoroughly upgraded residual stress diffractomer ARES-2 went in full operation in spring 2006 as well as the new neutron tomography device at GENRA-3. The installation of modern experiment control hardware and software based on LabView was completed on all designated instruments. In the appendices I and II the experimental reports of REFSANS at FRM II are attached as well as of the GKSS outstation HARWI-II at DESY. Both instruments started full operation in 2006. (orig.)

  2. Vibrational dynamics and band structure of methyl-terminated Ge(111)

    Energy Technology Data Exchange (ETDEWEB)

    Hund, Zachary M.; Nihill, Kevin J.; Sibener, S. J., E-mail: s-sibener@uchicago.edu [The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57" t" h Street, Chicago, Illinois 60637 (United States); Campi, Davide; Bernasconi, M. [Dipartimento di Scienza dei Materiali, Universita di Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Wong, Keith T.; Lewis, Nathan S. [Division of Chemistry and Chemical Engineering, Beckman Institute and Kavli Nanoscience Institute, California Institute of Technology, 210 Noyes Laboratory, 127-72, Pasadena, California 91125 (United States); Benedek, G. [Dipartimento di Scienza dei Materiali, Universita di Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Donostia International Physics Center (DIPC), Universidad del País Vasco (EHU), 20018 Donostia/San Sebastian (Spain)

    2015-09-28

    A combined synthesis, experiment, and theory approach, using elastic and inelastic helium atom scattering along with ab initio density functional perturbation theory, has been used to investigate the vibrational dynamics and band structure of a recently synthesized organic-functionalized semiconductor interface. Specifically, the thermal properties and lattice dynamics of the underlying Ge(111) semiconductor crystal in the presence of a commensurate (1 × 1) methyl adlayer were defined for atomically flat methylated Ge(111) surfaces. The mean-square atomic displacements were evaluated by analysis of the thermal attenuation of the elastic He diffraction intensities using the Debye-Waller model, revealing an interface with hybrid characteristics. The methyl adlayer vibrational modes are coupled with the Ge(111) substrate, resulting in significantly softer in-plane motion relative to rigid motion in the surface normal. Inelastic helium time-of-flight measurements revealed the excitations of the Rayleigh wave across the surface Brillouin zone, and such measurements were in agreement with the dispersion curves that were produced using density functional perturbation theory. The dispersion relations for H-Ge(111) indicated that a deviation in energy and lineshape for the Rayleigh wave was present along the nearest-neighbor direction. The effects of mass loading, as determined by calculations for CD{sub 3}-Ge(111), as well as by force constants, were less significant than the hybridization between the Rayleigh wave and methyl adlayer librations. The presence of mutually similar hybridization effects for CH{sub 3}-Ge(111) and CH{sub 3}-Si(111) surfaces extends the understanding of the relationship between the vibrational dynamics and the band structure of various semiconductor surfaces that have been functionalized with organic overlayers.

  3. Vibrational dynamics and band structure of methyl-terminated Ge(111)

    International Nuclear Information System (INIS)

    th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Hund, Zachary M.; th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Nihill, Kevin J.; th Street, Chicago, Illinois 60637 (United States))" data-affiliation=" (The James Franck Institute and Department of Chemistry, The University of Chicago, 929 E. 57th Street, Chicago, Illinois 60637 (United States))" >Sibener, S. J.; Campi, Davide; Bernasconi, M.; Wong, Keith T.; Lewis, Nathan S.; Benedek, G.

    2015-01-01

    A combined synthesis, experiment, and theory approach, using elastic and inelastic helium atom scattering along with ab initio density functional perturbation theory, has been used to investigate the vibrational dynamics and band structure of a recently synthesized organic-functionalized semiconductor interface. Specifically, the thermal properties and lattice dynamics of the underlying Ge(111) semiconductor crystal in the presence of a commensurate (1 × 1) methyl adlayer were defined for atomically flat methylated Ge(111) surfaces. The mean-square atomic displacements were evaluated by analysis of the thermal attenuation of the elastic He diffraction intensities using the Debye-Waller model, revealing an interface with hybrid characteristics. The methyl adlayer vibrational modes are coupled with the Ge(111) substrate, resulting in significantly softer in-plane motion relative to rigid motion in the surface normal. Inelastic helium time-of-flight measurements revealed the excitations of the Rayleigh wave across the surface Brillouin zone, and such measurements were in agreement with the dispersion curves that were produced using density functional perturbation theory. The dispersion relations for H-Ge(111) indicated that a deviation in energy and lineshape for the Rayleigh wave was present along the nearest-neighbor direction. The effects of mass loading, as determined by calculations for CD 3 -Ge(111), as well as by force constants, were less significant than the hybridization between the Rayleigh wave and methyl adlayer librations. The presence of mutually similar hybridization effects for CH 3 -Ge(111) and CH 3 -Si(111) surfaces extends the understanding of the relationship between the vibrational dynamics and the band structure of various semiconductor surfaces that have been functionalized with organic overlayers

  4. Molecular beam deposition of Al2O3 on p-Ge(001)/Ge0.95Sn0.05 heterostructure and impact of a Ge-cap interfacial layer

    International Nuclear Information System (INIS)

    Merckling, C.; Franquet, A.; Vincent, B.; Vandervorst, W.; Loo, R.; Caymax, M.; Sun, X.; Shimura, Y.; Takeuchi, S.; Nakatsuka, O.; Zaima, S.

    2011-01-01

    We investigated the molecular beam deposition of Al 2 O 3 on Ge 0.95 Sn 0.05 surface with and without an ultra thin Ge cap layer in between. We first studied the atomic configuration of both Ge 1-x Sn x and Ge/Ge 1-x Sn x surfaces after deoxidation by reflection high-energy electron diffraction and resulted, respectively, in a c(4x2) and (2x1) surface reconstructions. After in situ deposition of an Al 2 O 3 high-κ gate dielectric we evidenced using time-of-flight secondary ion mass spectroscopy analyses that Sn diffusion was at the origin of high leakage current densities in the Ge 1-x Sn x /Al 2 O 3 gate stack. This damage could be avoided by inserting a thin 5-nm-thick Ge cap between the oxide and the Ge 1-x Sn x layer. Finally, metal-oxide-semiconductor capacitors on the Ge capped sample showed well-behaved capacitance-voltage (C-V) characteristics with interface trap density (D it ) in the range of 10 12 eV -1 cm -2 in mid gap and higher close to the valence band edge.

  5. Radiotracer method for residence time distribution study in multiphase flow system

    International Nuclear Information System (INIS)

    Sugiharto, S.; Su'ud, Z.; Kurniadi, R.; Wibisono, W.; Abidin, Z.

    2009-01-01

    [ 131 I] isotope in different chemical compounds have been injected into 24 in hydrocarbon transmission pipeline containing approximately 95% water, 3% crude oil, 2% gas and negligible solid material, respectively. The system is operated at the temperature around 70 deg. C enabling fluids flow is easier in the pipeline. The segment of measurement was chosen far from the junction point of the pipeline, therefore, it was reasonably to assume that the fluids in such multiphase system were separated distinctively. Expandable tubing of injector was used to ensure that the isotopes were injected at the proper place in the sense that [ 131 I]Na isotope was injected into water layer and iodo-benzene, [131] IC 6 H 5, was injected into crude oil regime. The radiotracer selection was based on the compatibility of radiotracer with each of fluids under investigation. [ 131 I]Na was used for measuring flow of water while iodo-benzene, [131] IC 6 H 5, was used for measuring flow of crude oil. Two scintillation detectors were used and they are put at the distances 80 and 100 m, respectively, from injection point. The residence time distribution data were utilized for calculation water and crude oil flows. Several injections were conducted in the experiments. Although the crude oil density is lighter than the density of water, the result of measurement shows that the water flow is faster than the crude oil flow. As the system is water-dominated, water may act as carrier and the movement of crude oil is slowed due to friction between crude oil with water and crude oil with gas at top layer. Above of all, this result was able to give answer on the question why crude oil always arrives behind water as it is checked at gathering station. In addition, the flow patterns of the water in the pipeline calculated by Reynolds number and predicted by simple tank-in-series model is turbulence in character.

  6. In vitro characterization of [18F]-florbetaben, an Aβ imaging radiotracer

    International Nuclear Information System (INIS)

    Fodero-Tavoletti, Michelle T.; Brockschnieder, Damian; Villemagne, Victor L.; Martin, Lucas; Connor, Andrea R.; Thiele, Andrea; Berndt, Mathias; McLean, Catriona A.; Krause, Sabine; Rowe, Christopher C.; Masters, Colin L.; Dinkelborg, Ludger; Dyrks, Thomas; Cappai, Roberto

    2012-01-01

    Purpose: Amyloid-β (Aβ) plaques are a major pathological hallmark of Alzheimer's disease (AD). The noninvasive detection of Aβ plaques may increase the accuracy of clinical diagnosis as well as monitor therapeutic interventions. While [ 11 C]-PiB is the most widely used Aβ positron emission tomography (PET) radiotracer, due to the short half-life of 11 C (20 min), its application is limited to centers with an on-site cyclotron and 11 C radiochemistry expertise. Therefore, novel [ 18 F] (half-life 110 min)-labeled Aβ PET tracers have been developed. We have demonstrated that [ 18 F]-florbetaben-PET can differentiate individuals diagnosed with AD from healthy elderly, Parkinson's disease and frontotemporal lobe dementia (FTLD-tau) patients. While [ 18 F]-florbetaben-PET retention matched the reported postmortem distribution of Aβ plaques, the nature of [ 18 F]-florbetaben binding to other pathological lesions comprising misfolded proteins needs further assessment. The objective of this study was to determine whether Florbetaben selectively binds to Aβ plaques in postmortem tissue specimens containing mixed pathological hallmarks (i.e., tau and α-synuclein aggregates). Method: Human AD, FTLD-tau and dementia with Lewy bodies (DLB) brain sections were analyzed by [ 18 F]-florbetaben autoradiography and [ 3 H]-florbetaben high-resolution emulsion autoradiography and [ 19 F]-florbetaben fluorescence microscopy. Results: Both autoradiographical analyses demonstrated that Florbetaben exclusively bound Aβ plaques in AD brain sections at low nanomolar concentrations. Furthermore, at concentrations thousand-folds higher than those during a PET scan, [ 19 F]-florbetaben did not bind to α-synuclein or tau aggregates in DLB and FTLD-tau brain sections, respectively. Detection of [ 19 F]-florbetaben staining by fluorescence microscopy in several AD brain regions demonstrated that Florbetaben identified Aβ plaques in all brain regions examined. Conclusion: This study

  7. First isolation of enterovirus 71 (EV-71 from Northern Brazil

    Directory of Open Access Journals (Sweden)

    Lamarão Leticia Martins

    2003-01-01

    Full Text Available Enterovirus 71 (EV-71 has been associated to cases of neurological disease in many countries including Brazil. This virus has now been reported from three of the five Brazilian regions. Our study relates the findings concerning to the first isolate of this virus in Northern region of Brazil. A 15-month old female patient, from the rural zone of the municipality of Santana do Araguaia in southern Pará state was admitted at the hospital with acute, flaccid, asymmetric and ascending motor deficiency, located in the right lower limb. Stools samples from this child were inoculated in RD cells and was isolated an EV-71. We plan to sequence our strain and compare it to other isolates in Brazil. Differences at the molecular level can explain why EV-71 strains circulating in other continents, such as Asia, appear to be more virulent.

  8. Bi surfactant mediated growth for fabrication of Si/Ge nanostructures and investigation of Si/Ge intermixing by STM

    Energy Technology Data Exchange (ETDEWEB)

    Paul, N.

    2007-10-26

    In the thesis work presented here, we show that Bi is more promising surfactant material than Sb. We demonstrate that by using Bi as a terminating layer on Ge/Si surface, it is possible to distinguish between Si and Ge in Scanning tunnelling microscope (STM). Any attempt to utilize surfactant mediated growth must be preceded by a thorough study of its effect on the the system being investigated. Thus, the third chapter of this thesis deals with an extensive study of the Bi surfactant mediated growth of Ge on Si(111) surface as a function of Ge coverage. The growth is investigated from the single bilayer Ge coverage till the Ge coverage of about 15 BL when the further Ge deposition leads to two-dimensional growth. In the fourth chapter, the unique property of Bi terminating layer on Ge/Si surface to result in an STM height contrast between Si and Ge is explained with possible explanations given for the reason of this apparent height contrast. The controlled fabrication of Ge/Si nanostructures such as nanowires and nanorings is demonstrated. A study on Ge-Si diffusion in the surface layers by a direct method such as STM was impossible previously because of the similar electronic structure of Ge and Si. Since with the Bi terminating surface layer, one is able to distinguish between Ge and Si, the study of intermixing between them is also possible using STM. This method to distinguish between Si and Ge allows one to study intermixing on the nanoscale and to identify the fundamental diffusion processes giving rise to the intermixing. In Chapter 5 we discuss how this could prove useful especially as one could get a local probe over a very narrow Ge-Si interface. A new model is proposed to estimate change in the Ge concentration in the surface layer with time. The values of the activation energies of Ge/Si exchange and Si/Ge exchange are estimated by fitting the experimental data with the model. The Ge/Si intermixing has been studied on a surface having 1 ML Bi ({radical

  9. Vacancy-ordering effects in AlB2-type ErGe2 - x(0.4 < x < or = 0.5).

    Science.gov (United States)

    Christensen, Jeppe; Lidin, Sven; Malaman, Bernard; Venturini, Gerard

    2008-06-01

    In the Er-Ge system, the compostion range ErGe(2) to Er(2)Ge(3) has been investigated. Eight samples were produced by arc melting of the elements, and analyzed using X-ray powder diffraction. Nine crystal structures were found to be present in the samples. The structures are described as a homologous series and presented within the superspace formalism using the superspace group X2/m(alpha0gamma)0s, X representing the centring vector ((1/2), (1/2), 0, (1/2)). In this description the modulation vector q = (alphaa* + gammac*) is shown to be a direct measure of the Ge content as ErGe(2 - alpha) (alpha falls in the range 1\\over 3 to (1/2)). The large composition range is achieved by extended vacancy ordering in the planar 6(3) net of Ge with subsequent relaxation.

  10. Transient and temperature-dependent phenomena in Ge:Be and Ge:Zn far infrared photoconductors

    International Nuclear Information System (INIS)

    Haegel, N.M.

    1985-11-01

    An experimental study of the transient and temperature-dependent behavior of Ge:Be and Ge:Zn photoconductors has been performed under the low background photon flux conditions (p dot approx. = 10 8 photons/second) typical of astronomy and astrophysics applications. The responsivity of Ge:Be and Ge:Zn detectors is strongly temperature-dependent in closely compensated material, and the effect of compensation on free carrier lifetime in Ge:Be has been measured using the photo-Hall effect technique. Closely compensated material has been obtained by controlling the concentration of novel hydrogen-related shallow acceptor complexes, A(Be,H) and A(Zn,H), which exist in doped crystals grown under a H 2 atmosphere. A review of selection criteria for multilevel materials for optimum photoconductor performance is included. 55 refs., 47 figs

  11. Conceptual design of the Argonne 6-GeV synchrotron light source

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.; Khoe, T.

    1985-01-01

    The Argonne National Laboratory Synchrotron Light Source Storage Ring is designed to have a natural emittance of 6.5 x 10 -9 m for circulating 6-GeV positrons. Thirty of the 32 long straight sections, each 6.5-m long, will be available for synchrotron light insertion devices. A circulating positron current of 300 mA can be injected in about 8 min. from a booster synchrotron operating with a repetition time of 1.2 sec. The booster synchrotron will contain two different RF systems. The lower frequency system (38.97 MHz) will accept positrons from a 360-MeV linac and will accelerate them to 2.25 GeV. The higher frequency system (350.76 MHz) will accelerate the positrons to 6 GeV. The positrons will be produced from a 300-MeV electron beam on a tungsten target. A conceptual layout is shown

  12. Dopamine D2 receptor radiotracers [11C](+)-PHNO and [3H]raclopride are indistinguishably inhibited by D2 agonists and antagonists ex vivo

    International Nuclear Information System (INIS)

    McCormick, Patrick N.; Kapur, Shitij; Seeman, Philip; Wilson, Alan A.

    2008-01-01

    Introduction: In vitro, the dopamine D2 receptor exists in two states, with high and low affinity for agonists. The high-affinity state is the physiologically active state thought to be involved in dopaminergic illnesses such as schizophrenia. The positron emission tomography radiotracer [ 11 C](+)-PHNO ([ 11 C](+)-4-propyl-3,4,4a,5,6,10b-hexahydro-2H-naphtho[1,2-b][1,4] oxazin-9-o l), being a D2 agonist, should selectively label the high-affinity state at tracer dose and therefore be more susceptible to competition by agonist as compared to the antagonist [ 3 H]raclopride, which binds to both affinity states. Methods: We tested this prediction using ex vivo dual-radiotracer experiments in conscious rats. D2 antagonists (haloperidol or clozapine), a partial agonist (aripiprazole), a full agonist [(-)-NPA] or the dopamine-releasing drug amphetamine (AMPH) were administered to rats prior to an intravenous coinjection of [ 11 C](+)-PHNO and [ 3 H]raclopride. Rats were sacrificed 60 min after radiotracer injection. Striatum, cerebellum and plasma samples were counted for 11 C and 3 H. The specific binding ratio {SBR, i.e., [%ID/g (striatum)-%ID/g (cerebellum)]/(%ID/g (cerebellum)} was used as the outcome measure. Results: In response to D2 antagonists, partial agonist or full agonist, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs responded indistinguishably in terms of both ED 50 and Hill slope (e.g., (-)-NPA ED 50 values are 0.027 and 0.023 mg/kg for [ 11 C](+)-PHNO and [ 3 H]raclopride, respectively). In response to AMPH challenge, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs were inhibited to the same degree. Conclusions: We have shown that the SBRs of [ 11 C](+)-PHNO- and [ 3 H]raclopride do not differ in their response to agonist challenge. These results do not support predictions of the in vivo binding behavior of a D2 agonist radiotracer and cast some doubt on the in vivo applicability of the D2 two-state model, as described by in vitro binding experiments

  13. Testing FLUKA on neutron activation of Si and Ge at nuclear research reactor using gamma spectroscopy

    Science.gov (United States)

    Bazo, J.; Rojas, J. M.; Best, S.; Bruna, R.; Endress, E.; Mendoza, P.; Poma, V.; Gago, A. M.

    2018-03-01

    Samples of two characteristic semiconductor sensor materials, silicon and germanium, have been irradiated with neutrons produced at the RP-10 Nuclear Research Reactor at 4.5 MW. Their radionuclides photon spectra have been measured with high resolution gamma spectroscopy, quantifying four radioisotopes (28Al, 29Al for Si and 75Ge and 77Ge for Ge). We have compared the radionuclides production and their emission spectrum data with Monte Carlo simulation results from FLUKA. Thus we have tested FLUKA's low energy neutron library (ENDF/B-VIIR) and decay photon scoring with respect to the activation of these semiconductors. We conclude that FLUKA is capable of predicting relative photon peak amplitudes, with gamma intensities greater than 1%, of produced radionuclides with an average uncertainty of 13%. This work allows us to estimate the corresponding systematic error on neutron activation simulation studies of these sensor materials.

  14. The preparation of Nb3Ge thin film superconductors in a UHV evaporation and sputter device

    International Nuclear Information System (INIS)

    Krevet, B.; Schauer, W.; Wuechner, F.

    1978-10-01

    Thin film techniques like evaporation or sputtering are remarkbly suitable to vary the metallurgical and physical properties of superconductors in a wide range. In the case of the A15-compound Nb 3 Ge only these preparation techniques allow us to produce a metastable pure phase in stoichiometric composition and to study its superconducting properties. The presen report describes two UHV-plants to produce superconducting films by multisource coevaporation and cosputtering. Of special importance are the constancy, monitoring and control of the evaporation rate, and the thermalization of the sputter components on the other hand. The experimental methods used are explained in detail and discussed together with the results of Nb 3 Ge films. With the preparation parameters suitably chosen both techniques allow to prepare reproducibly Nb 3 Ge films with 21 K transition temperature (onset); under optimized conditions Tc values up to 22.3 K have been reached. (orig.) [de

  15. Development of gamma emitting receptor binding radiotracers for imaging the brain and pancreas. Final technical progress report, March 1, 1988--May 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This document give paragraph synopses of results in research on brain and pancreas imaging, using radiotracers. General catagories of research included chemistry, pharmacology, imaging physics, and kinetic modeling. A list of publications is included

  16. Status report of a 500 GeV S-band linear collider study

    International Nuclear Information System (INIS)

    Balewski, K.; Bieler, M.; Bothe, W.; Bredehoeft, K.; Brinkmann, R.; Choroba, S.; Dwersteg, B.; Ebert, M.; Febel, A.; Fischer, R.; Floettmann, K.; Holzer, B.; Juergensen, H.; Kouptsidis, J.; Kumpfert, H.; Loeffler, F.; Marx, M.; Narciss, H.; Neumann, R.; Peters, F.; Peters, M.; Pillat, P.; Rossbach, J.; Schumann, G.; Schwarz, W.; Vilcins, S.; Voss, G.A.; Werner, M.; Wipf, S.; Wuempelmann, H.; Beyer, H.G.; Dehler, M.; Dohlus, M.; Ebeling, F.; Hahne, P.; Holtkamp, N.; Klatt, R.; Krawczyk, F.; Tsakanov, V.; Rienen, U. van; Wanzenberg, R.; Weiland, T.; Wolter, H.

    1991-12-01

    This paper describes the status of a feasibility study of a 500 GeV center of mass linear collider, which is based almost entirely on conventional rf-technology. The basic components are S-band travelling wave, constant-gradient accelerating structures and 130 MW klystrons. 3 GeV damping rings are used to produce extremely small emittances in both planes which are in the same range as those of the next generation synchrotron light sources. Very strong focussing in the linear accelerator and near the interaction region, as well as a dedicated chromatic correction scheme, are necessary to achieve spot sizes that have not been produced yet. The methods envisaged to stabilize the motion of the tiny beam along the 15 km long linac seem promising and give rise to be assumption that the proposed values can be reached with todays' available technology. (orig.)

  17. The interface quality of Ge nanoparticles grown in thick silica matrix

    Energy Technology Data Exchange (ETDEWEB)

    Dasović, J.; Dubček, P.; Pucić, I. [RuđerBošković Institute, Bijenička 54, Zagreb 10000 (Croatia); Bernstorff, S. [Elettra-Sincrotrone Trieste, SS 14, km 163.5, Basovizza (TS) (Italy); Radić, N. [RuđerBošković Institute, Bijenička 54, Zagreb 10000 (Croatia); Pivac, B., E-mail: pivac@irb.hr [RuđerBošković Institute, Bijenička 54, Zagreb 10000 (Croatia)

    2017-08-31

    Highlights: • Ge nanoparticles were grown in SiO{sub 2} matrix by magnetron sputtering. • GISAXS analysis was used to study nanoparticles. • Nanoparticle's surface exhibit fractal nature that affect other properties. - Abstract: Germanium nanoparticles, or Ge quantum dots (QDs), embedded in different transparent dielectric matrix exhibit properties significantly different from the same bulk semiconductor and therefore exhibit a considerable potential for applications in advanced electronic and optoelectronic devices. It is expected that the quantum confinement effect will tune the optical bandgap simply by varying the QDs size. Nevertheless, the question remains whether and how the defects often present in the matrix or at interfaces affect their properties. A thick (SiO{sub 2} + Ge) layer was deposited by magnetron sputtering and after suitable thermal treatment spherical Ge QDs were formed in SiO{sub 2} matrix with rather narrow size distribution, as confirmed by GIWAXS and GISAXS analysis. It is shown that the formed surface/interface of the QDs with the matrix was rough with fractal nature. Annealing in N{sub 2} atmosphere produced photoluminescence (PL) in the visible part of the spectrum which consists of three contributions. All are attributed to structural defects at or close to the Ge/SiO{sub x} interface. Time-resolved PL results support the assumption that the three components are dominant in the observed luminescence.

  18. Synthesis and in vivo evaluation of novel radiotracers for the in vivo imaging of the norepinephrine transporter

    International Nuclear Information System (INIS)

    Wilson, Alan A.; Patrick Johnson, David; Mozley, David; Hussey, Doug; Ginovart, Nathalie; Nobrega, Jose; Garcia, Armando; Meyer, Jeffery; Houle, Sylvain

    2003-01-01

    The (R,R) and (S,S) enantiomers of 2-[(2-methoxyphenoxy)phenylmethyl]morpholine (MeNER) have been radiolabelled with carbon-11 in good yield and at high specific activity. These radiotracers are close analogues of reboxetine, a potent and selective ligand for the norepinephrine transporter (NET). They were examined as potential ligands for imaging NET in vivo by positron emission tomography (PET). The in vivo brain distribution of both [ 11 C]-labeled enantiomers were evaluated in rats. Following tail-vein injection of the (R,R)-enantiomer regional brain uptake and washout of radioactivity was homogeneous at all time points examined (5-60 min). In contrast, administration of the (S,S)-enantiomer produced a heterogeneous distribution of radioactivity in brain with highest uptake in the hypothalamus, a NET rich region, and lowest uptake in the striatum, a brain region devoid of NET. Hypothalamus to striatum ratios of 2.5 to one were achieved at 60 min post injection of (S,S)-[ 11 C]-MeNER. Pre-injection of the norepinephrine reuptake inhibitors, reboxetine or desipramine, reduced hypothalamus to striatum ratios to near unity while reuptake inhibitors of dopamine and serotonin had no significant effect on binding. In vitro autoradiography studies (rat brain slices) with (S,S)-[ 11 C]-MeNER produced a regional distribution pattern that was consistent with the reported distribution of NET. (S,S)-[ 11 C]-MeNER has the potential to be the first successful PET ligand to image NET

  19. Synthesis and in vivo evaluation of novel radiotracers for the in vivo imaging of the norepinephrine transporter

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Alan A. E-mail: aaw@camhpet.on.ca; Patrick Johnson, David; Mozley, David; Hussey, Doug; Ginovart, Nathalie; Nobrega, Jose; Garcia, Armando; Meyer, Jeffery; Houle, Sylvain

    2003-02-01

    The (R,R) and (S,S) enantiomers of 2-[(2-methoxyphenoxy)phenylmethyl]morpholine (MeNER) have been radiolabelled with carbon-11 in good yield and at high specific activity. These radiotracers are close analogues of reboxetine, a potent and selective ligand for the norepinephrine transporter (NET). They were examined as potential ligands for imaging NET in vivo by positron emission tomography (PET). The in vivo brain distribution of both [{sup 11}C]-labeled enantiomers were evaluated in rats. Following tail-vein injection of the (R,R)-enantiomer regional brain uptake and washout of radioactivity was homogeneous at all time points examined (5-60 min). In contrast, administration of the (S,S)-enantiomer produced a heterogeneous distribution of radioactivity in brain with highest uptake in the hypothalamus, a NET rich region, and lowest uptake in the striatum, a brain region devoid of NET. Hypothalamus to striatum ratios of 2.5 to one were achieved at 60 min post injection of (S,S)-[{sup 11}C]-MeNER. Pre-injection of the norepinephrine reuptake inhibitors, reboxetine or desipramine, reduced hypothalamus to striatum ratios to near unity while reuptake inhibitors of dopamine and serotonin had no significant effect on binding. In vitro autoradiography studies (rat brain slices) with (S,S)-[{sup 11}C]-MeNER produced a regional distribution pattern that was consistent with the reported distribution of NET. (S,S)-[{sup 11}C]-MeNER has the potential to be the first successful PET ligand to image NET.

  20. Estimative of dilution factor for radioactive liquid effluents employing the H-3 and Cs-137 radiotracers present as pollutant

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa; Santos, Adir Janete Godoy dos

    2011-01-01

    It was estimated the dilution factor for liquid effluents at the discharge points of the IPEN, Sao Paulo, Brazil, employing as radiotracers the radioisotope routinely liberated for the sewage of 'Cidade Universitaria Armando de Salles Oliveira' - CUASO 3 H and 137 Cs, not generating either monetary or environmental cost associated to the estimation. The 137 Cs was determined by gamma spectrometry and the 3 H was determined liquid phase scintillation. The results showed that the dilution factor varied according to the employed radiotracer in a crescent order of 3 H and 137 Cs according to the characteristics of each element. The average of dilution factors obtained at the first and second liberation day were 4.3 and 7.4 respectively for the 3 H and 6.2 and 13.9 for the 137 Cs. The ratio of dilution factors of calculated 3 H and 137 Cs were coherent with the ratio verified at the twelve hydrometers distributed by the IPEN campus. The dilution factors were estimated in operational and laboratory study, in a single controlled discharge of the TR1 tank