WorldWideScience

Sample records for procedures surveillance procedures

  1. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  2. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  3. Surface Environmental Surveillance Procedures Manual, PNL-MA-580, Rev. 5

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, Robert W.; Poston, Ted M.; Bisping, Lynn E.

    2007-07-01

    This manual contains the procedures that are used for the collection of routine Surface Environmental Surveillance Project environmental samples and field measurements on and around the Hanford Site. Specific responsibilities for project personnel are also defined.

  4. Surveillance procedure for the rotary drilling operations of a well

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, B; Deshais, R

    1988-06-17

    A surveillance procedure for the rotary drilling operations of a well is proposed. When the drilling pipe is drawn out of the well, or put into the well, pipe elements are taken away or added. At each moment the height of the trepan in the well is measured, together with the traction force of the lifting engine. The device permits to avoid the important damage that can be caused by an error on the drilling pipe's length.

  5. Surveillance procedure for the rotary drilling operations of a well

    Energy Technology Data Exchange (ETDEWEB)

    Peltier, B.; Deshais, R.

    1988-06-17

    A surveillance procedure for the rotary drilling operations of a well is proposed. When the drilling pipe is drawn out of the well, or put into the well, pipe elements are taken away or added. At each moment the height of the trepan in the well is measured, together with the traction force of the lifting engine. The device permits to avoid the important damage that can be caused by an error on the drilling pipe's length.

  6. Reduction procedures for accurate analysis of MSX surveillance experiment data

    Science.gov (United States)

    Gaposchkin, E. Mike; Lane, Mark T.; Abbot, Rick I.

    1994-01-01

    Technical challenges of the Midcourse Space Experiment (MSX) science instruments require careful characterization and calibration of these sensors for analysis of surveillance experiment data. Procedures for reduction of Resident Space Object (RSO) detections will be presented which include refinement and calibration of the metric and radiometric (and photometric) data and calculation of a precise MSX ephemeris. Examples will be given which support the reduction, and these are taken from ground-test data similar in characteristics to the MSX sensors and from the IRAS satellite RSO detections. Examples to demonstrate the calculation of a precise ephemeris will be provided from satellites in similar orbits which are equipped with S-band transponders.

  7. 28 CFR 550.31 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... the allotted time period. An inmate may rebut this presumption during the disciplinary process. (b... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Procedures. 550.31 Section 550.31... Urine Surveillance § 550.31 Procedures. (a) Staff of the same sex as the inmate tested shall directly...

  8. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  9. In-Trail Procedure Air Traffic Control Procedures Validation Simulation Study

    Science.gov (United States)

    Chartrand, Ryan C.; Hewitt, Katrin P.; Sweeney, Peter B.; Graff, Thomas J.; Jones, Kenneth M.

    2012-01-01

    In August 2007, Airservices Australia (Airservices) and the United States National Aeronautics and Space Administration (NASA) conducted a validation experiment of the air traffic control (ATC) procedures associated with the Automatic Dependant Surveillance-Broadcast (ADS-B) In-Trail Procedure (ITP). ITP is an Airborne Traffic Situation Awareness (ATSA) application designed for near-term use in procedural airspace in which ADS-B data are used to facilitate climb and descent maneuvers. NASA and Airservices conducted the experiment in Airservices simulator in Melbourne, Australia. Twelve current operational air traffic controllers participated in the experiment, which identified aspects of the ITP that could be improved (mainly in the communication and controller approval process). Results showed that controllers viewed the ITP as valid and acceptable. This paper describes the experiment design and results.

  10. Playing the Panopticon : Procedural punishment in Dark Souls

    NARCIS (Netherlands)

    van Nuenen, Tom

    2015-01-01

    This article investigates discursive procedures in From Software’s 2011 videogame Dark Souls. By combining procedural rhetorics, discourse analysis, and autoethnographical research play, it is argued that Dark Souls features post-Panoptical gameplay mechanics of both continuous surveillance and

  11. Intensive care unit audit: invasive procedure surveillance

    Directory of Open Access Journals (Sweden)

    Mariama Amaral Michels

    2013-01-01

    Full Text Available Rationale and objective: currently, Healthcare-associated Infections (HAIs constitute a serious public health problem. It is estimated that for every ten hospitalized patients, one will have infection after admission, generating high costs resulting from increased length of hospitalization, additional diagnostic and therapeutic interventions. The intensive care unit (ICU, due to its characteristics, is one of the most complex units of the hospital environment, a result of the equipment, the available technology, the severity of inpatients and the invasive procedures the latter are submitted to. The aim of the study was to evaluate the adherence to specifi c HAI prevention measures in invasive ICU procedures. Methods: This study had a quantitative, descriptive and exploratory approach. Among the risk factors for HAIs are the presence of central venous access, indwelling vesical catheter and mechanical ventilation, and, therefore, the indicators were calculated for patients undergoing these invasive procedures, through a questionnaire standardized by the Hospital Infection Control Commission (HICC. Results: For every 1,000 patients, 15 had catheter-related bloodstream infection, 6.85 had urinary tract infection associated with indwelling catheter in the fi rst half of 2010. Conclusion: most HAIs cannot be prevented, for reasons inherent to invasive procedures and the patients. However, their incidence can be reduced and controlled. The implementation of preventive measures based on scientifi c evidence can reduce HAIs signifi cantly and sustainably, resulting in safer health care services and reduced costs. The main means of prevention include the cleaning of hands, use of epidemiological block measures, when necessary, and specifi c care for each infection site. KEYWORDS Nosocomial infection. Intensive care units.

  12. The Spanish national health care-associated infection surveillance network (INCLIMECC): data summary January 1997 through December 2006 adapted to the new National Healthcare Safety Network Procedure-associated module codes.

    Science.gov (United States)

    Pérez, Cristina Díaz-Agero; Rodela, Ana Robustillo; Monge Jodrá, Vincente

    2009-12-01

    In 1997, a national standardized surveillance system (designated INCLIMECC [Indicadores Clínicos de Mejora Continua de la Calidad]) was established in Spain for health care-associated infection (HAI) in surgery patients, based on the National Nosocomial Infection Surveillance (NNIS) system. In 2005, in its procedure-associated module, the National Healthcare Safety Network (NHSN) inherited the NNIS program for surveillance of HAI in surgery patients and reorganized all surgical procedures. INCLIMECC actively monitors all patients referred to the surgical ward of each participating hospital. We present a summary of the data collected from January 1997 to December 2006 adapted to the new NHSN procedures. Surgical site infection (SSI) rates are provided by operative procedure and NNIS risk index category. Further quality indicators reported are surgical complications, length of stay, antimicrobial prophylaxis, mortality, readmission because of infection or other complication, and revision surgery. Because the ICD-9-CM surgery procedure code is included in each patient's record, we were able to reorganize our database avoiding the loss of extensive information, as has occurred with other systems.

  13. An overview of the Environmental Response Team's air surveillance procedures at emergency response activities

    Energy Technology Data Exchange (ETDEWEB)

    Turpin, R.D.; Campagna, P.R. (U.S. Environmental Protection Agency, Edison, NJ (USA))

    The Safety and Air Surveillance Section of the United States Environmental Protection Agency's Environmental Response Team responds to emergency air releases such as tire fires and explosions. The air surveillance equipment and procedures used by the organization are described, and case studies demonstrating the various emergency response activities are presented. Air response activities include emergency air responses, occupational and human health air responses and remedial air responses. Monitoring and sampling equipment includes photoionization detectors, combustible gas meters, real-time aerosol monitors, personal sampling pumps, and high flow pumps. Case histories presented include disposal of dioxane from a cotton plant, response to oil well fires in Kuwait, disposal of high pressure cylinders in American Samoa, and response to hurricane Hugo. 3 refs., 1 tab.

  14. Random effect modelling of patient-related risk factors in orthopaedic procedures: results from the Dutch nosocomial infection surveillance network 'PREZIES'.

    NARCIS (Netherlands)

    Muilwijk, J; Walenkamp, G H I M; Voss, Andreas; Wille, Jan C; Hof, Susan van den

    2006-01-01

    In the Dutch surveillance for surgical site infections (SSIs), data from 70277 orthopaedic procedures with 1895 SSIs were collected between 1996 and 2003. The aims of this study were: (1) to analyse the trends in SSIs associated with Gram-positive and Gram-negative bacteria; (2) to estimate

  15. 28 CFR 550.44 - Procedures for arranging drug counseling.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Procedures for arranging drug counseling... MANAGEMENT DRUG PROGRAMS Drug Services (Urine Surveillance and Counseling for Sentenced Inmates in Contract CTCs) § 550.44 Procedures for arranging drug counseling. The contract center staff shall hold a program...

  16. Health and Safety Procedures Manual for hazardous waste sites

    Energy Technology Data Exchange (ETDEWEB)

    Thate, J.E.

    1992-09-01

    The Oak Ridge National Laboratory Chemical Assessments Team (ORNL/CAT) has developed this Health and Safety Procedures Manual for the guidance, instruction, and protection of ORNL/CAT personnel expected to be involved in hazardous waste site assessments and remedial actions. This manual addresses general and site-specific concerns for protecting personnel, the general public, and the environment from any possible hazardous exposures. The components of this manual include: medical surveillance, guidance for determination and monitoring of hazards, personnel and training requirements, protective clothing and equipment requirements, procedures for controlling work functions, procedures for handling emergency response situations, decontamination procedures for personnel and equipment, associated legal requirements, and safe drilling practices.

  17. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  18. Sedation for procedures outside the operating room in children

    International Nuclear Information System (INIS)

    Molina Rodriguez, Ericka

    2014-01-01

    Sedation is defined in the pediatric population. An adequate preoperative assessment is established in patients subjected to a sedation. Fundamental characteristics of drugs used during a sedation are determined. Recommendations about surveillance and monitoring are established in a patient sedated. Principal characteristics of sedation are defined in patients exposed to radiological diagnostic and therapeutic procedures. Considerations in sedation are identified for procedures in the laboratory of digestive endoscopy. Alternatives of sedation are mentioned for oncological patients subjected to invasive procedures. Working conditions and specifications of anesthesia are determined in the cardiac catheterization room [es

  19. Quality assurance procedures for the IAEA Department of Safeguards Twin Minolta Camera Surveillance System

    International Nuclear Information System (INIS)

    Geoffrion, R.R.; Bussolini, P.L.; Stark, W.A.; Ahlquist, A.J.; Sanders, K.E.; Rubinstein, G.

    1986-01-01

    The International Atomic Energy Agency (IAEA) safeguards program provides assurance to the international community that nations are complying with nuclear safeguards treaties. In one aspect of the program, the Department of Safeguards has developed a twin Minolta camera photo surveillance systems program to assure itself and the international community that material handling is accomplished according to safeguards treaty regulations. The camera systems are positioned in strategic locations in facilities such that objective evidence can be obtained for material transactions. The films are then processed, reviewed, and used to substantiate the conclusions that nuclear material has not been diverted. Procedures have been developed to document and aid in: 1) the performance of activities involved in positioning of the camera system; 2) installation of the systems; 3) review and use of the film taken from the cameras

  20. Administrative Procedure Act and mass procedures (illustrated by the nuclear licensing procedure)

    International Nuclear Information System (INIS)

    Naumann, R.

    1977-01-01

    The report deals with the administrative procedure law of 25.5.76 of the Fed. Government, esp. with its meaning for the administrative procedures for the permission for nuclear power plants, as fas ar so-called mass procedures are concerned. (UN) [de

  1. Radioimmunoassay and related procedures in medicine 1982

    International Nuclear Information System (INIS)

    1982-01-01

    Of the 77 papers submitted, 69 were included in INIS. The papers included in the proceedings cover the following sessions: reagents and separation procedures; assay for free hormones; assay for biological substances; assay for drugs; data processing; intralaboratory quality control; external surveillance of assay performance; assay service in developing countries; public health applications; clinical applications; alternatives to radioassay

  2. Emergency procedures

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following subjects are discussed - Emergency Procedures: emergency equipment, emergency procedures; emergency procedure involving X-Ray equipment; emergency procedure involving radioactive sources

  3. AGREED-UPON PROCEDURES, PROCEDURES FOR AUDITING EUROPEAN GRANTS

    Directory of Open Access Journals (Sweden)

    Daniel Petru VARTEIU

    2016-12-01

    The audit of EU-funded projects is an audit based on agreed-upon procedures, which are established by the Managing Authority or the Intermediate Body. Agreed-upon procedures can be defined as engagements made in accordance with ISRS 4400, applicable to agreed-upon procedures, where the auditor undertakes to carry out the agreed-upon procedures and issue a report on factual findings. The report provided by the auditor does not express any assurance. It allows users to form their own opinions about the conformity of the expenses with the project budget as well as the eligibility of the expenses.

  4. French legislation on food irradiation - Licensing procedure

    International Nuclear Information System (INIS)

    Souverain, R.

    1977-01-01

    French legislation on food irradiation subjects marketing of such foodstuffs to a prior licence granted by an interministerial order on the type of goodstuff concerned. The basic text on the licensing procedure is the Decree of 8 May 1970 whose purpose is to ensure the health and safety of the consumer by laying down instructions for the operations, surveillance and labelling, which must set out clearly the type of treatment. (NEA) [fr

  5. Quantization Procedures

    International Nuclear Information System (INIS)

    Cabrera, J. A.; Martin, R.

    1976-01-01

    We present in this work a review of the conventional quantization procedure, the proposed by I.E. Segal and a new quantization procedure similar to this one for use in non linear problems. We apply this quantization procedures to different potentials and we obtain the appropriate equations of motion. It is shown that for the linear case the three procedures exposed are equivalent but for the non linear cases we obtain different equations of motion and different energy spectra. (Author) 16 refs

  6. Efficiency of performing pulmonary procedures in a shared endoscopy unit: procedure time, turnaround time, delays, and procedure waiting time.

    Science.gov (United States)

    Verma, Akash; Lee, Mui Yok; Wang, Chunhong; Hussein, Nurmalah B M; Selvi, Kalai; Tee, Augustine

    2014-04-01

    The purpose of this study was to assess the efficiency of performing pulmonary procedures in the endoscopy unit in a large teaching hospital. A prospective study from May 20 to July 19, 2013, was designed. The main outcome measures were procedure delays and their reasons, duration of procedural steps starting from patient's arrival to endoscopy unit, turnaround time, total case durations, and procedure wait time. A total of 65 procedures were observed. The most common procedure was BAL (61%) followed by TBLB (31%). Overall procedures for 35 (53.8%) of 65 patients were delayed by ≥ 30 minutes, 21/35 (60%) because of "spillover" of the gastrointestinal and surgical cases into the time block of pulmonary procedure. Time elapsed between end of pulmonary procedure and start of the next procedure was ≥ 30 minutes in 8/51 (16%) of cases. In 18/51 (35%) patients there was no next case in the room after completion of the pulmonary procedure. The average idle time of the room after the end of pulmonary procedure and start of next case or end of shift at 5:00 PM if no next case was 58 ± 53 minutes. In 17/51 (33%) patients the room's idle time was >60 minutes. A total of 52.3% of patients had the wait time >2 days and 11% had it ≥ 6 days, reason in 15/21 (71%) being unavailability of the slot. Most pulmonary procedures were delayed due to spillover of the gastrointestinal and surgical cases into the block time allocated to pulmonary procedures. The most common reason for difficulty encountered in scheduling the pulmonary procedure was slot unavailability. This caused increased procedure waiting time. The strategies to reduce procedure delays and turnaround times, along with improved scheduling methods, may have a favorable impact on the volume of procedures performed in the unit thereby optimizing the existing resources.

  7. Medical Procedures and Risk for Sporadic Creutzfeldt-Jakob Disease, Japan, 1999–2008

    Science.gov (United States)

    Hamaguchi, Tsuyoshi; Noguchi-Shinohara, Moeko; Nozaki, Ichiro; Nakamura, Yosikazu; Sato, Takeshi; Kitamoto, Tetsuyuki; Mizusawa, Hidehiro

    2009-01-01

    To elucidate the association between medical procedures and sporadic Creutzfeldt-Jakob disease (sCJD), we analyzed medical procedures (any surgical procedure, neurosurgery, ophthalmic surgery, and blood transfusion) for patients registered by the CJD Surveillance Committee in Japan during 1999–2008. We conducted an age-stratified case–control study with 753 sCJD patients and 210 controls and a study of patients who underwent neurosurgical or ophthalmic surgical procedures at the same hospital. Although the control group was relatively small, no evidence was found that prion disease was transmitted through the investigated medical procedures before onset of sCJD. After onset of sCJD, 4.5% of the sCJD patients underwent operations, including neurosurgical for 0.8% and ophthalmic for 1.9%; no special precautions against transmission of prion diseases were taken. Fortunately, we have not identified patients with prion disease attributed to these operations. Our findings indicate that surgical procedures or blood transfusion had little effect on the incidence of sCJD. PMID:19193271

  8. Good practices with respect to the development and use of nuclear power plant procedures

    International Nuclear Information System (INIS)

    1998-12-01

    This technical publication is intended to provide information to nuclear power plant managers concerning good practices in respect to the development and use of NPP procedures. It is a part of an ongoing project on nuclear power plant instrumentation and control and is based on lessons learned from NPPs and utilities. The overall objective of this project is to provide systematic guidance on current and emerging instrumentation and control technologies including: protection and automation systems, control rooms, operator support systems, training simulators and human factors. It is intended to be applicable to NPPs in Member States that are in operation, under construction or being commissioned. The good practices described are consistent with the IAEA Safety Series recommendations with respect to the development and use of NPP procedures including the four categories: administrative procedures, operating procedures (normal, alarm response, abnormal and emergency procedures), maintenance and technical support procedures, and testing and surveillance procedures

  9. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  10. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  11. Human factoring administrative procedures

    International Nuclear Information System (INIS)

    Grider, D.A.; Sturdivant, M.H.

    1991-01-01

    In nonnuclear business, administrative procedures bring to mind such mundane topics as filing correspondence and scheduling vacation time. In the nuclear industry, on the other hand, administrative procedures play a vital role in assuring the safe operation of a facility. For some time now, industry focus has been on improving technical procedures. Significant efforts are under way to produce technical procedure requires that a validated technical, regulatory, and administrative basis be developed and that the technical process be established for each procedure. Producing usable technical procedures requires that procedure presentation be engineered to the same human factors principles used in control room design. The vital safety role of administrative procedures requires that they be just as sound, just a rigorously formulated, and documented as technical procedures. Procedure programs at the Tennessee Valley Authority and at Boston Edison's Pilgrim Station demonstrate that human factors engineering techniques can be applied effectively to technical procedures. With a few modifications, those same techniques can be used to produce more effective administrative procedures. Efforts are under way at the US Department of Energy Nuclear Weapons Complex and at some utilities (Boston Edison, for instance) to apply human factors engineering to administrative procedures: The techniques being adapted include the following

  12. Spline-procedures

    International Nuclear Information System (INIS)

    Schmidt, R.

    1976-12-01

    This report contains a short introduction to spline functions as well as a complete description of the spline procedures presently available in the HMI-library. These include polynomial splines (using either B-splines or one-sided basis representations) and natural splines, as well as their application to interpolation, quasiinterpolation, L 2 -, and Tchebycheff approximation. Special procedures are included for the case of cubic splines. Complete test examples with input and output are provided for each of the procedures. (orig.) [de

  13. Procedural Media Representation

    OpenAIRE

    Henrysson, Anders

    2002-01-01

    We present a concept for using procedural techniques to represent media. Procedural methods allow us to represent digital media (2D images, 3D environments etc.) with very little information and to render it photo realistically. Since not all kind of content can be created procedurally, traditional media representations (bitmaps, polygons etc.) must be used as well. We have adopted an object-based media representation where an object can be represented either with a procedure or with its trad...

  14. PUREX (SAMCONS) uninterruptible power supply (UPS) acceptance test procedure

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Procedure for the PUREX Surveillance and Monitoring and Control System (SAMCONS) Uninterruptible Power Supply (UPS) provides for testing and verifying the proper operation of the control panel alarms and trouble functions, the 6roper functioning of the AC inverter, ability of the battery supply to maintain the SAMCONS load for a minimum of two hours , and proper interaction with the SAMCONS Video graphic displays for alarm displays

  15. Procedure generation and verification

    International Nuclear Information System (INIS)

    Sheely, W.F.

    1986-01-01

    The Department of Energy has used Artificial Intelligence of ''AI'' concepts to develop two powerful new computer-based techniques to enhance safety in nuclear applications. The Procedure Generation System, and the Procedure Verification System, can be adapted to other commercial applications, such as a manufacturing plant. The Procedure Generation System can create a procedure to deal with the off-normal condition. The operator can then take correct actions on the system in minimal time. The Verification System evaluates the logic of the Procedure Generator's conclusions. This evaluation uses logic techniques totally independent of the Procedure Generator. The rapid, accurate generation and verification of corrective procedures can greatly reduce the human error, possible in a complex (stressful/high stress) situation

  16. Are minimally invasive procedures harder to acquire than conventional surgical procedures?

    Science.gov (United States)

    Hiemstra, Ellen; Kolkman, Wendela; le Cessie, Saskia; Jansen, Frank Willem

    2011-01-01

    It is frequently suggested that minimally invasive surgery (MIS) is harder to acquire than conventional surgery. To test this hypothesis, residents' learning curves of both surgical skills are compared. Residents had to be assessed using a general global rating scale of the OSATS (Objective Structured Assessment of Technical Skills) for every procedure they performed as primary surgeon during a 3-month clinical rotation in gynecological surgery. Nine postgraduate-year-4 residents collected a total of 319 OSATS during the 2 years and 3 months investigation period. These assessments concerned 129 MIS (laparoscopic and hysteroscopic) and 190 conventional (open abdominal and vaginal) procedures. Learning curves (in this study defined as OSATS score plotted against procedure-specific caseload) for MIS and conventional surgery were compared using a linear mixed model. The MIS curve revealed to be steeper than the conventional curve (1.77 vs. 0.75 OSATS points per assessed procedure; 95% CI 1.19-2.35 vs. 0.15-1.35, p < 0.01). Basic MIS procedures do not seem harder to acquire during residency than conventional surgical procedures. This may have resulted from the incorporation of structured MIS training programs in residency. Hopefully, this will lead to a more successful implementation of the advanced MIS procedures. Copyright © 2010 S. Karger AG, Basel.

  17. Play vs. Procedures

    DEFF Research Database (Denmark)

    Hammar, Emil

    Through the theories of play by Gadamer (2004) and Henricks (2006), I will show how the relationship between play and game can be understood as dialectic and disruptive, thus challenging understandings of how the procedures of games determine player activity and vice versa. As such, I posit some...... analytical consequences for understandings of digital games as procedurally fixed (Boghost, 2006; Flannagan, 2009; Bathwaite & Sharp, 2010). That is, if digital games are argued to be procedurally fixed and if play is an appropriative and dialectic activity, then it could be argued that the latter affects...... and alters the former, and vice versa. Consequently, if the appointed procedures of a game are no longer fixed and rigid in their conveyance of meaning, qua the appropriative and dissolving nature of play, then understandings of games as conveying a fixed meaning through their procedures are inadequate...

  18. Measuring variability of procedure progression in proceduralized scenarios

    International Nuclear Information System (INIS)

    Kim, Yochan; Park, Jinkyun; Jung, Wondea

    2012-01-01

    Highlights: ► The VPP measure was developed to quantify how differently operators follow the procedures. ► Sources that cause variability of ways to follow a given procedure were identified. ► The VPP values for the scenarios are positively related to the scenario performance time. ► The VPP measure is meaningful for explaining characteristics of several PSFs. -- Abstract: Various performance shaping factors (PSFs) have been presented to explain the contributors to unsafe acts in a human failure event or predict a human error probability of new human performance. However, because most of these parameters of an HRA depend on the subjective knowledge and experience of HRA analyzers, the results of an HRA insufficiently provide unbiased standards to explain human performance variations or compare collected data with other data from different analyzers. To secure the validity of the HRA results, we propose a quantitative measure, which represents the variability of procedure progression (VPP) in proceduralized scenarios. A VPP measure shows how differently the operators follow the steps of the procedures. This paper introduces the sources of the VPP measure and relevance to PSFs. The assessment method of the VPP measure is also proposed, and the application examples are shown with a comparison of the performance time. Although more empirical studies should be conducted to reveal the relationship between the VPP measure and other PSFs, it is believed that the VPP measure provides evidence to quantitatively evaluate human performance variations and to cross-culturally compare the collected data.

  19. Advanced structural integrity assessment procedures. Working material

    International Nuclear Information System (INIS)

    1994-01-01

    The purpose of the meeting was to provide an international forum for discussion on recent results in research and utility practice in the field of methodology for the structural integrity assessment of components including relevant non-codified procedures. The scope of the meeting included deterministic and probabilistic approaches. The papers covered the following topics: Leak-before-break concepts; non-destructive examination (NDE) and surveillance results; statistical evaluation of non-destructive examination data; pressurized thermal shock evaluation; fatigue effects (including vibration); and verification qualification. The meeting was attended by 32 specialists from 8 countries. Refs, figs and tabs

  20. Procedural sedation analgesia

    OpenAIRE

    Sheta, Saad A

    2010-01-01

    The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA). The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interve...

  1. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  2. Transversal of Procedure Elements in a Computerized Procedure System

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yeonsub [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    APR1400 MCR(Main Control Room) has introduced CPS(Computerized Procedure System). APR400 CPS is framed with overview pane, step detail pane, and monitoring pane. The overview shows the step in one dimensional array. Diagram in the step detail pane is called as flowlogic diagram. The flowlogic diagram has advantage of being intuitive and not being segmented so that the interfaces are easy to follow and understand. While developing CPS software or training operators these interfaces, however, there is still areas to refine behaviors of flowlogic diagram. If flowlogic diagram has contingency instructions, it is sometime difficult to interpret it properly. Therefore this paper is trying to explain behavior of flowlogic diagram in view of procedure elements. Procedure execution can be called as transversal of steps and instructions in flowlogic diagram. Both hierarchy of procedures elements and flowlogic diagram provides useful framework to test transversal with completeness. Navigation button behaviors are interpreted in view of flowlogic diagram. The framework and flowlogic diagram can be further applied to improve CPS user interfaces.

  3. Infection Rate after Cranial Neurosurgical Procedures: A Prospective Single-Center Study.

    Science.gov (United States)

    Strahm, Carol; Albrich, Werner C; Zdravkovic, Vilijam; Schöbi, Barbara; Hildebrandt, Gerhard; Schlegel, Matthias

    2018-03-01

    To determine infection rate (IR) and to identify modifiable risk factors (RF) in cranial neurosurgery in a neurosurgical department for tertiary referral as part of an infection control surveillance to reduce surgical site infections (SSI). A prospective SSI incidence cohort study from February 2013 to January 2014 was performed in a tertiary-care neurosurgical teaching hospital and referral center. All consecutive adults undergoing any cranial neurosurgical procedure were included. Data were collected by a trained member of the infection control staff during the twice-weekly visits of the hospitalized patients. Follow-up was 30 days (procedures without implant) and 1 year (procedures involving permanent implants). SSI was diagnosed according to criteria of CDC. A total of 317 patients undergoing 333 index procedures were included. The median age was 61 years (range, 17-91 years) and 46% were female. Survival in patients with completed follow-up was 76% (196/258). Overall, IR was 7.2% (24/333 index procedures); in 96% (23/24), a neurosurgical implant was involved. The IR of extraventricular drainage (EVD) was 12.5% (13.1/1000 EVD days). The main causative pathogens were Staphylococcus aureus followed by coagulase-negative staphylococci and Propionibacterium acnes. Independent RF for neurosurgical SSI were EVD as part of the index operation and body mass index >25 kg/m 2 . IR was in accordance with recent prospective single-center studies (reported IR between 1.6% and 9%). EVD placement was identified as the strongest modifiable RF for SSI in cranial neurosurgical procedures. The need for standard infection control procedures for the insertion and maintenance of EVDs to avoid their contamination is reinforced. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  5. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  6. Environmental procedures

    International Nuclear Information System (INIS)

    1992-01-01

    The European Bank has pledged in its Agreement to place environmental management at the forefront of its operations to promote sustainable economic development in central and eastern Europe. The Bank's environmental policy is set out in the document titled, Environmental Management: The Bank's Policy Approach. This document, Environmental Procedures, presents the procedures which the European Bank has adopted to implement this policy approach with respect to its operations. The environmental procedures aim to: ensure that throughout the project approval process, those in positions of responsibility for approving projects are aware of the environmental implications of the project, and can take these into account when making decisions; avoid potential liabilities that could undermine the success of a project for its sponsors and the Bank; ensure that environmental costs are estimated along with other costs and liabilities; and identify opportunities for environmental enhancement associated with projects. The review of environmental aspects of projects is conducted by many Bank staff members throughout the project's life. This document defines the responsibilities of the people and groups involved in implementing the environmental procedures. Annexes contain Environmental Management: The Bank's Policy Approach, examples of environmental documentation for the project file and other ancillary information

  7. Civil Procedure In Denmark

    DEFF Research Database (Denmark)

    Werlauff, Erik

    scientific activities conducted by the author, partly based on the author's experience as a member, through a number of years, of the Danish Standing Committee on Procedural Law (Retsplejeraadet), which on a continuous basis evaluates the need for civil procedural reforms in Denmark, and finally also based......The book contains an up-to-date survey of Danish civil procedure after the profound Danish procedural reforms in 2007. It deals with questions concerning competence and function of Danish courts, commencement and preparation of civil cases, questions of evidence and burden of proof, international...... procedural questions, including relations to the Brussels I Regulation and Denmark's participation in this Regulation via a parallel convention with the EU countries, impact on Danish civil procedure of the convention on human rights, preparation and pronouncement of judgment and verdict, questions of appeal...

  8. Guidelines on the facilities required for minor surgical procedures and minimal access interventions.

    LENUS (Irish Health Repository)

    Humphreys, H

    2012-02-01

    There have been many changes in healthcare provision in recent years, including the delivery of some surgical services in primary care or in day surgery centres, which were previously provided by acute hospitals. Developments in the fields of interventional radiology and cardiology have further expanded the range and complexity of procedures undertaken in these settings. In the face of these changes there is a need to define from an infection prevention and control perspective the basic physical requirements for facilities in which such surgical procedures may be carried out. Under the auspices of the Healthcare Infection Society, we have developed the following recommendations for those designing new facilities or upgrading existing facilities. These draw upon best practice, available evidence, other guidelines where appropriate, and expert consensus to provide sensible and feasible advice. An attempt is also made to define minimal access interventions and minor surgical procedures. For minimal access interventions, including interventional radiology, new facilities should be mechanically ventilated to achieve 15 air changes per hour but natural ventilation is satisfactory for minor procedures. All procedures should involve a checklist and operators should be appropriately trained. There is also a need for prospective surveillance to accurately determine the post-procedure infection rate. Finally, there is a requirement for appropriate applied research to develop the evidence base required to support subsequent iterations of this guidance.

  9. Electronic Procedures for Medical Operations

    Science.gov (United States)

    2015-01-01

    Electronic procedures are replacing text-based documents for recording the steps in performing medical operations aboard the International Space Station. S&K Aerospace, LLC, has developed a content-based electronic system-based on the Extensible Markup Language (XML) standard-that separates text from formatting standards and tags items contained in procedures so they can be recognized by other electronic systems. For example, to change a standard format, electronic procedures are changed in a single batch process, and the entire body of procedures will have the new format. Procedures can be quickly searched to determine which are affected by software and hardware changes. Similarly, procedures are easily shared with other electronic systems. The system also enables real-time data capture and automatic bookmarking of current procedure steps. In Phase II of the project, S&K Aerospace developed a Procedure Representation Language (PRL) and tools to support the creation and maintenance of electronic procedures for medical operations. The goal is to develop these tools in such a way that new advances can be inserted easily, leading to an eventual medical decision support system.

  10. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  11. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  12. Decision-making Procedures

    DEFF Research Database (Denmark)

    Aldashev, Gani; Kirchsteiger, Georg; Sebald, Alexander Christopher

    2009-01-01

    define procedures as mechanisms that influence the probabilities of reaching different endnodes. We show that for such procedural games a sequential psychological equilibrium always exists. Applying this approach within a principal-agent context we show that the way less attractive jobs are allocated...

  13. Procedural sedation analgesia

    Directory of Open Access Journals (Sweden)

    Sheta Saad

    2010-01-01

    Full Text Available The number of noninvasive and minimally invasive procedures performed outside of the operating room has grown exponentially over the last several decades. Sedation, analgesia, or both may be needed for many of these interventional or diagnostic procedures. Individualized care is important when determining if a patient requires procedural sedation analgesia (PSA. The patient might need an anti-anxiety drug, pain medicine, immobilization, simple reassurance, or a combination of these interventions. The goals of PSA in four different multidisciplinary practices namely; emergency, dentistry, radiology and gastrointestinal endoscopy are discussed in this review article. Some procedures are painful, others painless. Therefore, goals of PSA vary widely. Sedation management can range from minimal sedation, to the extent of minimal anesthesia. Procedural sedation in emergency department (ED usually requires combinations of multiple agents to reach desired effects of analgesia plus anxiolysis. However, in dental practice, moderate sedation analgesia (known to the dentists as conscious sedation is usually what is required. It is usually most effective with the combined use of local anesthesia. The mainstay of success for painless imaging is absolute immobility. Immobility can be achieved by deep sedation or minimal anesthesia. On the other hand, moderate sedation, deep sedation, minimal anesthesia and conventional general anesthesia can be all utilized for management of gastrointestinal endoscopy.

  14. RADCHEM - Radiochemical procedures for the determination of Sr, U, Pu, Am and Cm

    Energy Technology Data Exchange (ETDEWEB)

    Sidhu, R. [Inst. for Energy Technology (Norway)

    2006-04-15

    An accurate determination of radionuclides from various sources in the environment is essential for assessment of the potential hazards and suitable countermeasures both in case of accidents, authorised release and routine surveillance. Reliable radiochemical separation and detection techniques are needed for accurate determination of alpha and beta emitters. Rapid analytical methods are needed in case of an accident for early decision-making. The objective of this project has been to compare and evaluate radiochemical procedures used at Nordic laboratories for the determination of strontium, uranium, plutonium, americium and curium. To gather detailed information on the procedures in use, a questionnaire regarding various aspects of radionuclide determination was developed and distributed to all (sixteen) relevant laboratories in the Nordic countries. The response and the procedures used by each laboratory were then discussed between those who answered the questionnaire. This report summaries the findings and gives recommendation on suitable practice. (au)

  15. RADCHEM - Radiochemical procedures for the determination of Sr, U, Pu, Am and Cm

    International Nuclear Information System (INIS)

    Sidhu, R.

    2006-04-01

    An accurate determination of radionuclides from various sources in the environment is essential for assessment of the potential hazards and suitable countermeasures both in case of accidents, authorised release and routine surveillance. Reliable radiochemical separation and detection techniques are needed for accurate determination of alpha and beta emitters. Rapid analytical methods are needed in case of an accident for early decision-making. The objective of this project has been to compare and evaluate radiochemical procedures used at Nordic laboratories for the determination of strontium, uranium, plutonium, americium and curium. To gather detailed information on the procedures in use, a questionnaire regarding various aspects of radionuclide determination was developed and distributed to all (sixteen) relevant laboratories in the Nordic countries. The response and the procedures used by each laboratory were then discussed between those who answered the questionnaire. This report summaries the findings and gives recommendation on suitable practice. (au)

  16. Actor-Network Procedures

    NARCIS (Netherlands)

    Pavlovic, Dusko; Meadows, Catherine; Ramanujam, R.; Ramaswamy, Srini

    2012-01-01

    In this paper we propose actor-networks as a formal model of computation in heterogenous networks of computers, humans and their devices, where these new procedures run; and we introduce Procedure Derivation Logic (PDL) as a framework for reasoning about security in actor-networks, as an extension

  17. Sentinel node biopsy (SNB) in malignant melanoma as same day procedure vs delayed procedure

    DEFF Research Database (Denmark)

    Rødgaard, Jes Christian; Kramer, Stine; Stolle, Lars B

    2013-01-01

    The aim of this study was to compare a delayed sentinel node biopsy (dSNB) procedure with a same-day procedure (sSNB) in malignant melanoma. In March 2012, Aarhus University Hospital went from the dSNB to the sSNB procedure defined by lymphoscintigraphy (LS) and sentinel node biopsy (SNB) perform......, essential to keep the morbidity and economic costs low, while keeping the quality of the procedure high....

  18. Model of Procedure Usage – Results from a Qualitative Study to Inform Design of Computer-Based Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Johanna H Oxstrand; Katya L Le Blanc

    2012-07-01

    The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use performance, researchers, together with the nuclear industry, have been looking at replacing the current paper-based procedures with computer-based procedure systems. The concept of computer-based procedures is not new by any means; however most research has focused on procedures used in the main control room. Procedures reviewed in these efforts are mainly emergency operating procedures and normal operating procedures. Based on lessons learned for these previous efforts we are now exploring a more unknown application for computer based procedures - field procedures, i.e. procedures used by nuclear equipment operators and maintenance technicians. The Idaho National Laboratory, the Institute for Energy Technology, and participants from the U.S. commercial nuclear industry are collaborating in an applied research effort with the objective of developing requirements and specifications for a computer-based procedure system to be used by field operators. The goal is to identify the types of human errors that can be mitigated by using computer-based procedures and how to best design the computer-based procedures to do this. The underlying philosophy in the research effort is “Stop – Start – Continue”, i.e. what features from the use of paper-based procedures should we not incorporate (Stop), what should we keep (Continue), and what new features or work processes should be added (Start). One step in identifying the Stop – Start – Continue was to conduct a baseline study where affordances related to the current usage of paper-based procedures were identified. The purpose of the study was to develop a model of paper based procedure use which will help to identify desirable features for computer based procedure prototypes. Affordances such as note taking, markups

  19. Procedures for evaluating technical specifications (PETS)

    International Nuclear Information System (INIS)

    Samanta, P.K.; Boccio, J.L.; Vesely, W.E.

    1987-01-01

    In this paper, aspects of technical specifications relating to Generic Issues B-56 and B-61 are discussed from a risk-standpoint. These primarily deal with the risk issues associated with (1) adaptive diesel test requirements/surveillance test intervals, and (2) the effectiveness of cumulative outage time requirements for controlling downtime risk. Risk and reliability approaches are presented which (1) allow risk-acceptable test intervals to be determined for any diesel and (2) show the potential risk-control capability of prescribed allowed cumulative outage times. This work was conducted through NRC's Procedures for Evaluating Technical Specifications (PETS) Program. The overall objective of this program is to develop and demonstrate methodologies that utilize risk insights and reliability techniques for evaluating the scope, detailed requirements, and safety impact of plant technical specifications

  20. [Costing nuclear medicine diagnostic procedures].

    Science.gov (United States)

    Markou, Pavlos

    2005-01-01

    To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges.

  1. FREY’S PROCEDURE- TO ANALYSE THE OUTCOME OF THIS PROCEDURE IN CHRONIC PANCREATITIS

    Directory of Open Access Journals (Sweden)

    Shilpa Mariappa Casaba

    2017-04-01

    Full Text Available BACKGROUND Chronic Pancreatitis (CP is a progressive inflammatory disease characterised by debilitating pain and pancreatic insufficiency. There is enormous personal and socio-economic impact on impairment of quality of life, inability to work and even shortening of life expectancy. Although, pancreaticoduodenectomy had been considered the standard surgical procedure for patients with CP because of its high post-op complications with exocrine and endocrine insufficiency, it is not preferred. This has led to a hybrid procedure described by Frey’s, which is used in our study for CP. We aim to analyse the short-term and long-term outcomes of Frey’s procedure at a tertiary care center in patients with chronic pancreatitis. MATERIALS AND METHODS A retrospective review of all CP patients who underwent Frey procedure were reviewed from January 2007-January 2016. Perioperative variables, short-term (30 days and long-term (3 years outcomes were reviewed. Data are frequency (% or mean. RESULTS A total of 97 patients underwent Frey’s procedure. A total of 72 (70.7% were men and 25 (29.3% were women. Mean age was 38 years (range 14-66 years. Indications for surgery included intractable pain (n=97, 100% and obstructive jaundice (n=4, 4.3%. 9 patients (32.6% were diabetic preoperatively. Concomitant procedures include biliary drainage procedure was done for 4 patients (4.3%, i.e. choledochojejunostomy and splenectomy for 2 patients (2.1%, cholecystectomy (n=6, 6%. Short-term outcomes include surgical site infection (n=10, 10%, pancreatic leak (n=6, 5.82% and 2 patients required reoperation for bleeding and no mortality (30 days, diabetic ketoacidosis (n=2, 2%. Pancreatic carcinoma was detected in 3 (2.1% patients. Long-term outcomes include pain free status (n=80, 86.9%, median follow-up of 3 years. Redo pancreatic procedure was performed in 1 (4.3% for anastomotic leak. CONCLUSION Frey’s procedure is a safe and effective pain palliative option for CP

  2. Procedure for taking physical inventories

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This session is intended to apprise one of the various aspects of procedures and routines that Exxon Nuclear uses with respect to its nuclear materials physical inventory program. The presentation describes how plant physical inventories are planned and taken. The description includes the planning and preparation for taking the inventory, the clean-out procedures for converting in-process material to measurable items, the administrative procedures for establishing independent inventory teams and for inventorying each inventory area, the verification procedures used to include previously measured tamper-safed items in the inventory, and lastly, procedures used to reconcile the inventory and calculate MUF (materials unaccounted for). The purpose of the session is to enable participants to: (1) understand the planning and pre-inventorty procedures and their importance; (2) understand the need for and the required intensity of clean-out procedures; (3) understand how inventory teams are formed, and how the inventory is conducted; (4) understand the distinction between inventory previously measured tamper-safed items and other materials not so characterized; (5) understand the reconciliation procedures; and (6) calculate a MUF given the book and inventory results

  3. Electronic procedure distribution

    International Nuclear Information System (INIS)

    Slone, B.J. III; Richardson, C.E.

    1993-01-01

    Printed procedures can offer a mix of text and graphic information that improves readability and increases understanding. A typical procedure uses illustrations and graphics to clarify concepts, a variety of type styles and weights to make it easier to find different topics and sections, white space to improve readability, and familiar navigational clues such as page numbers and topic headers. Initially, electronic procedure systems had limited typeface options, often only a single typeface, with no capability for enhancing readability by varying type size bolding, italicizing, or underlining, and no ability to include graphics. Even recently, many text-only electronic procedures were originally created in a modern What-You-See-Is-What-You-Get (WYSI-WYG) document authoring system, only to be converted to pages and pages of plain type for electronic distribution. Given the choice of paper or on-line producers, most users have chosen paper for its readability. But current-generation electronic document systems that use formatted text and embedded graphics offer users vastly improved readability. Further, they are offering ever-better search tools to enable rapid location of material of interest

  4. Modified arthroscopic Brostrom procedure.

    Science.gov (United States)

    Lui, Tun Hing

    2015-09-01

    The open modified Brostrom anatomic repair technique is widely accepted as the reference standard for lateral ankle stabilization. However, there is high incidence of intra-articular pathologies associated with chronic lateral ankle instability which may not be addressed by an isolated open Brostrom procedure. Arthroscopic Brostrom procedure with suture anchor has been described for anatomic repair of chronic lateral ankle instability and management of intra-articular lesions. However, the complication rates seemed to be higher than open Brostrom procedure. Modification of the arthroscopic Brostrom procedure with the use of bone tunnel may reduce the risk of certain complications. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. Radiation surveillance procedure during veterinary application of radioisotope

    International Nuclear Information System (INIS)

    Kamaldeep; Bhaktivinayagam, A.; Singh, Sanjay Kumar

    2012-01-01

    Radioisotopes have found wide applications in the field of biomedical veterinary nuclear medicine and research. Radiation safety issues during internal administration of radioisotopes to laboratory animals, unlike human use, are far more challenging and requires stringent, well planned and an organized system of radiation protection in the animal house facility. In this paper, we discuss our experience during veterinary research experiments involving use, handling and administration of liquid sources of 131 I. With extensive radiation protection surveillance and application of practical and essential radiation safety and hygiene practices, the radiation exposure and contamination levels during the veterinary application of isotopes can be kept ALARA

  6. Comparing the operators' behavior in conducting emergency operating procedures with the complexity of procedural steps

    International Nuclear Information System (INIS)

    Park, Jin Kyun; Jung, Won Dea

    2003-01-01

    Many kinds of procedures have been used to reduce the operators' workload throughout various industries. However, significant portion of accidents or incidents was caused by procedure related human errors that are originated from non-compliance of procedures. According to related studies, several important factors for non-compliance behavior have been identified, and one if them is the complexity of procedures. This means that comparing the change of the operators' behavior with the complexity of procedures may be meaningful for investigating plausible reasons for the operators' non-compliance behavior. In this study, emergency training records were collected using a full scope simulator in order to obtain data related to the operators' non-compliance behavior. And then, collected data are compared with the complexity of procedural steps. As the result, two remarkable relationships are found, which indicate that the operators' behavior could be reasonably characterized by the complexity of procedural steps. Thus, these relationships can be used as meaningful clues not only to scrutinize the reason of non-compliance behavior but also to suggest appropriate remedies for the reduction of non-compliance behavior that can result in procedure related human errors

  7. 76 FR 50740 - Draft Guidance for Industry and Food and Drug Administration Staff; Procedures for Handling...

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0514] Draft Guidance for Industry and Food and Drug Administration Staff; Procedures for Handling Section 522 Postmarket Surveillance Studies; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice...

  8. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    International Nuclear Information System (INIS)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-01-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  9. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-02-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  10. Pelvic denervation procedures for dysmenorrhea.

    Science.gov (United States)

    Ramirez, Christina; Donnellan, Nicole

    2017-08-01

    Chronic pelvic pain and dysmenorrhea are common conditions affecting reproductive-age women. Surgical pelvic denervation procedures may be a treatment option for women with midline dysmenorrhea, in which medical management is declined by the patient, ineffective at managing symptoms, or medically contraindicated. This review describes the surgical techniques and complications associated with pelvic denervation procedures as well as the current evidence for these procedures in women with primary dysmenorrhea and dysmenorrhea secondary to endometriosis. Presacral neurectomy is the preferred pelvic denervation procedure in patients with primary dysmenorrhea and midline chronic pelvic pain associated with endometriosis. In patients with endometriosis presacral neurectomy is a useful adjunct to excision or ablation of all endometrial lesions to improve postoperative pain relief. There is no additional patient benefit of performing combined presacral neurectomy and uterine nerve ablation procedures. Pelvic denervation procedures can be performed safely and quickly with a low risk of complication if the surgeon is knowledgeable and skilled in operating in the presacral space. Patients should be adequately counseled on expected success rates and potential complications associated with pelvic denervation procedures.

  11. The impact of a medical procedure service on patient safety, procedure quality and resident training opportunities.

    Science.gov (United States)

    Tukey, Melissa H; Wiener, Renda Soylemez

    2014-03-01

    At some academic hospitals, medical procedure services are being developed to provide supervision for residents performing bedside procedures in hopes of improving patient safety and resident education. There is limited knowledge of the impact of such services on procedural complication rates and resident procedural training opportunities. To determine the impact of a medical procedure service (MPS) on patient safety and resident procedural training opportunities. Retrospective cohort analysis comparing characteristics and outcomes of procedures performed by the MPS versus the primary medical service. Consecutive adults admitted to internal medicine services at a large academic hospital who underwent a bedside medical procedure (central venous catheterization, thoracentesis, paracentesis, lumbar puncture) between 1 July 2010 and 31 December 2011. The primary outcome was a composite rate of major complications. Secondary outcomes included resident participation in bedside procedures and use of "best practice" safety process measures. We evaluated 1,707 bedside procedures (548 by the MPS, 1,159 by the primary services). There were no differences in the composite rate of major complications (1.6 % vs. 1.9 %, p = 0.71) or resident participation in bedside procedures (57.0 % vs. 54.3 %, p = 0.31) between the MPS and the primary services. Procedures performed by the MPS were more likely to be successfully completed (95.8 % vs. 92.8 %, p = 0.02) and to use best practice safety process measures, including use of ultrasound guidance when appropriate (96.8 % vs. 90.0 %, p = 0.0004), avoidance of femoral venous catheterization (89.5 vs. 82.7 %, p = 0.02) and involvement of attending physicians (99.3 % vs. 57.0 %, p < 0.0001). Although use of a MPS did not significantly affect the rate of major complications or resident opportunities for training in bedside procedures, it was associated with increased use of best practice safety process measures.

  12. 76 FR 62092 - Filing Procedures

    Science.gov (United States)

    2011-10-06

    ... INTERNATIONAL TRADE COMMISSION Filing Procedures AGENCY: International Trade Commission. ACTION: Notice of issuance of Handbook on Filing Procedures. SUMMARY: The United States International Trade Commission (``Commission'') is issuing a Handbook on Filing Procedures to replace its Handbook on Electronic...

  13. Dynamic alarm response procedures

    International Nuclear Information System (INIS)

    Martin, J.; Gordon, P.; Fitch, K.

    2006-01-01

    The Dynamic Alarm Response Procedure (DARP) system provides a robust, Web-based alternative to existing hard-copy alarm response procedures. This paperless system improves performance by eliminating time wasted looking up paper procedures by number, looking up plant process values and equipment and component status at graphical display or panels, and maintenance of the procedures. Because it is a Web-based system, it is platform independent. DARP's can be served from any Web server that supports CGI scripting, such as Apache R , IIS R , TclHTTPD, and others. DARP pages can be viewed in any Web browser that supports Javascript and Scalable Vector Graphics (SVG), such as Netscape R , Microsoft Internet Explorer R , Mozilla Firefox R , Opera R , and others. (authors)

  14. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection

    International Nuclear Information System (INIS)

    Martin, Douglas J.; Rad, Arash Ehteshami; Kallmes, David F.

    2012-01-01

    Background: Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. Purpose: To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, post procedure plain radiographs, and post procedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. Material and Methods: With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and pre vertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ 2 test. Results: One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34 %, 95 % CI 28-42 %) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and pre vertebral venous (n = 32, 18%, 95% CI 13-24%). Conclusion: Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography

  15. Procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Doyle, T.; Hare, W.S.C.; Thomson, K.; Tess, B.

    1989-01-01

    This book outlines the various procedures necessary for the successful practice of diagnostic radiology. Topics covered are: general principles, imaging of the urinary and gastrointestinal tracts, vascular radiology, arthrography, and miscellaneous diagnostic radiologic procedures

  16. Using Procedure Codes to Define Radiation Toxicity in Administrative Data: The Devil is in the Details.

    Science.gov (United States)

    Meyer, Anne-Marie; Kuo, Tzy-Mey; Chang, YunKyung; Carpenter, William R; Chen, Ronald C; Sturmer, Til

    2017-05-01

    Systematic coding systems are used to define clinically meaningful outcomes when leveraging administrative claims data for research. How and when these codes are applied within a research study can have implications for the study validity and their specificity can vary significantly depending on treatment received. Data are from the Surveillance, Epidemiology, and End Results-Medicare linked dataset. We use propensity score methods in a retrospective cohort of prostate cancer patients first examined in a recently published radiation oncology comparative effectiveness study. With the narrowly defined outcome definition, the toxicity event outcome rate ratio was 0.88 per 100 person-years (95% confidence interval, 0.71-1.08). With the broadly defined outcome, the rate ratio was comparable, with 0.89 per 100 person-years (95% confidence interval, 0.76-1.04), although individual event rates were doubled. Some evidence of surveillance bias was suggested by a higher rate of endoscopic procedures the first year of follow-up in patients who received proton therapy compared with those receiving intensity-modulated radiation treatment (11.15 vs. 8.90, respectively). This study demonstrates the risk of introducing bias through subjective application of procedure codes. Careful consideration is required when using procedure codes to define outcomes in administrative data.

  17. INITIATION AND CONDUCT OF ADMINISTRATIVE PROCEDURE

    Directory of Open Access Journals (Sweden)

    Milan Stipic

    2013-12-01

    Full Text Available General administrative procedure act contains legal norms that are valid for all identical cases. In addition to the general, there are special administrative procedures, customized to the specific administrative areas. Procedure initiation is regulated. Administrative procedure can be initiated at the request of the proponent and ex officio. When the official determines that the conditions for the conduct of administrative procedure are met, before making a decision, all the facts and circumstances relevant to the resolution of administrative matter have to be identified. When there are no legal requirements for the initiation of procedures, the official shall make a decision to reject the application of the party. The procedure is initiated ex officio when stipulated by law or when protection of public interest requires it. When initiating procedure ex officio, the public authority shall take into consideration the petition or other information that indicate the need to protect the public interest. In such cases the applicant is not a party, and the official is obliged to notify the applicant, if initiation of procedures is not accepted ex officio. Based on the notification, the applicant has a right to complain, including the situation when there is no response within the prescribed period of 30 days. Public authority may, therefore it is not obliged to, initiate administrative procedure by public announcement only in a situation where the parties are unknown, while it is obliged to initiate procedure by public announcement when this method of initiating the procedure is prescribed by law. Initiation of procedure with public announcement occurs in rare cases. Due to the application of efficiency and cost-effectiveness principle, two or more administrative procedures can be merged into one procedure by a conclusion. The condition for this is that the rights or obligations of the parties are based on the same legal basis and on the same or

  18. Quantization Procedures; Sistemas de cuantificacion

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, J. A.; Martin, R.

    1976-07-01

    We present in this work a review of the conventional quantization procedure, the proposed by I.E. Segal and a new quantization procedure similar to this one for use in non linear problems. We apply this quantization procedures to different potentials and we obtain the appropriate equations of motion. It is shown that for the linear case the three procedures exposed are equivalent but for the non linear cases we obtain different equations of motion and different energy spectra. (Author) 16 refs.

  19. Simplified Laboratory Runoff Procedure (SLRP): Procedure and Application

    National Research Council Canada - National Science Library

    Price, Richard

    2000-01-01

    The Simplified Laboratory Runoff Procedure (SLRP) was developed to provide a faster, less expensive approach to evaluate surface runoff water quality from dredged material placed in an upland environment...

  20. COPMA-III - Intelligent handling of existing procedures

    International Nuclear Information System (INIS)

    Hulsund, John-Einar; Jung, Yeonsub; Nilsen, Svein

    1999-04-01

    This report describes how COPMA-III makes it possible to enhance old procedures without having to change much of their original layout. By means of COPMA-III one can insert into the old procedure text tags that describe the 'meaning' of the various textual elements in the procedure. Those tags can be made invisible to the person using the procedure, but the computer is able to inspect the tags and give appropriate assistance in carrying through the procedure. Previous versions of COPMA required a reformulation and most often a re-structuring of the procedures before taking them into use. A fixed set of instructions and a fixed procedure structure made the computerised procedure different from the original procedure (in most cases). This is no more so in COPMA-III. By means of small procedural elements (microelements), it is possible to configure the COPMA-III system to fit the set of instructions and the procedure structure that is being used in the old procedure system. This report describes an example case, starting with an old procedure, goes through a set of working steps and ends up with a procedure having exactly the same appearance as the old procedure, but having assistance from the COPMA-III system in executing the procedure (author) (ml)

  1. Aesthetic procedures in office practice.

    Science.gov (United States)

    Small, Rebecca

    2009-12-01

    Since the approval of botulinum toxin, dermal fillers, and lasers for cosmetic use, minimally invasive aesthetic procedures have rapidly become the treatments of choice for age-related facial changes. In the past 10 years, aesthetic procedures have increased nearly five-fold. Of the 10.2 million aesthetic treatments performed in 2008, 83 percent were minimally invasive procedures. Botulinum toxin and dermal filler injections, laser hair reduction, chemical peels, laser skin resurfacing, microdermabrasion, and intense pulsed light photorejuvenation were the most commonly performed procedures in 2008. These procedures are effective and associated with minimal discomfort, and they have a low incidence of adverse effects and short recovery times. High patient and physician satisfaction have contributed to their growing popularity and availability in the primary care setting. As patient demand for aesthetic treatments increases, family physicians should be familiar with common minimally invasive aesthetic procedures when advising patients or incorporating aesthetic care into office practice.

  2. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  3. 18 CFR 301.3 - Filing procedures.

    Science.gov (United States)

    2010-04-01

    ... FOR SALES FROM UTILITIES TO BONNEVILLE POWER ADMINISTRATION UNDER NORTHWEST POWER ACT § 301.3 Filing procedures. (a) Bonneville's ASC review procedures. The procedures established by Bonneville's Administrator... Bonneville's ASC review procedures. (b) Exchange Period. The Exchange Period will be equal to the term of...

  4. 32 CFR 635.35 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Procedures. 635.35 Section 635.35 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS LAW ENFORCEMENT REPORTING Victim and Witness Assistance Procedures § 635.35 Procedures. (a) As required by Federal law, Army personnel...

  5. Developing, adopting and adapting operating procedures

    International Nuclear Information System (INIS)

    Rabouhams, J.

    1986-01-01

    This lecture specifies all the dispositions which have been taken by EDF Nuclear and Fossil Generation Department - according to the fact that availability and safety largely depend on the quality of the procedures and their easy handling - in order to develop, adopt and adapt the operating procedures. The following points are treated: General organization of procedures for plant operation during normal and abnormal conditions; Personnel and extend of responsibility involved into the development of procedures (research center, training center, specialized services, nuclear station, etc.); Validation of the procedures by means of full-scope simulators; Modifications of the procedures taking into account operation experience in material and human fields; Development of simulation softs in order to perform the procedures in abnormal situations; Evolution of operating technics and future skills. (orig.)

  6. The Bentall procedure in patients with Marfan's syndrome.

    Science.gov (United States)

    Nguyen, K H; Ergin, M A; Galla, J D; Lansman, S L; McCullough, J N; Griepp, R B

    1997-01-01

    From 1985 to 1996, 18 patients with Marfan's syndrome underwent the Bentall procedure at Mount Sinai Hospital. They are compared with 38 patients aged Marfan's syndrome who also underwent composite valve-graft replacement of the ascending aorta. The mean age of the non-Marfan group was 33 while that of the Marfan group was 29. Nearly three-quarters of each group were male. Aortic dissection was present in 33% of the Marfan group but only in 18% of the other group. Seventy-eight percent of the Marfan patients and 89% of the non-Marfan patients had aortic regurgitation. Twenty-one percent of the patients in the control group nevertheless had gross aortic pathology suggestive of Marfan's syndrome and may have had variants of the syndrome; 26% of the non-Marfan group had a bicuspid aortic valve. A modification of the Bentall procedure with implantation of coronary artery buttons was performed in the majority of the patients in both groups. Three patients, all in the group with Marfan's syndrome, required a concomitant mitral valve procedure. There was one death in each group. Two non-Marfan patients required reoperation; neither had dissection. Four patients with Marfan's syndrome underwent reoperation for distal disease in the aorta; they comprised one third of the Marfan patients who had aortic dissection. Three late complications occurred in the group with Marfan's syndrome: progressive cardiomyopathy; myocardial infarction; and late tamponade. There were also two late sudden deaths in the group with Marfan's syndrome, which may have been the consequence of aortic rupture. No difference in immediate operative mortality following the Bentall procedure was noted between patients with and without Marfan's syndrome, but young patients without Marfan's syndrome seem to have better event-free and long-term survival. In patients with Marfan's syndrome, the presence of acute dissection makes reoperation more likely, and sudden death from rupture still occurs despite careful

  7. Collected radiochemical and geochemical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kleinberg, J [comp.

    1990-05-01

    This revision of LA-1721, 4th Ed., Collected Radiochemical Procedures, reflects the activities of two groups in the Isotope and Nuclear Chemistry Division of the Los Alamos National Laboratory: INC-11, Nuclear and radiochemistry; and INC-7, Isotope Geochemistry. The procedures fall into five categories: I. Separation of Radionuclides from Uranium, Fission-Product Solutions, and Nuclear Debris; II. Separation of Products from Irradiated Targets; III. Preparation of Samples for Mass Spectrometric Analysis; IV. Dissolution Procedures; and V. Geochemical Procedures. With one exception, the first category of procedures is ordered by the positions of the elements in the Periodic Table, with separate parts on the Representative Elements (the A groups); the d-Transition Elements (the B groups and the Transition Triads); and the Lanthanides (Rare Earths) and Actinides (the 4f- and 5f-Transition Elements). The members of Group IIIB-- scandium, yttrium, and lanthanum--are included with the lanthanides, elements they resemble closely in chemistry and with which they occur in nature. The procedures dealing with the isolation of products from irradiated targets are arranged by target element.

  8. Procedure automation: the effect of automated procedure execution on situation awareness and human performance

    International Nuclear Information System (INIS)

    Andresen, Gisle; Svengren, Haakan; Heimdal, Jan O.; Nilsen, Svein; Hulsund, John-Einar; Bisio, Rossella; Debroise, Xavier

    2004-04-01

    As advised by the procedure workshop convened in Halden in 2000, the Halden Project conducted an experiment on the effect of automation of Computerised Procedure Systems (CPS) on situation awareness and human performance. The expected outcome of the study was to provide input for guidance on CPS design, and to support the Halden Project's ongoing research on human reliability analysis. The experiment was performed in HAMMLAB using the HAMBO BWR simulator and the COPMA-III CPS. Eight crews of operators from Forsmark 3 and Oskarshamn 3 participated. Three research questions were investigated: 1) Does procedure automation create Out-Of-The-Loop (OOTL) performance problems? 2) Does procedure automation affect situation awareness? 3) Does procedure automation affect crew performance? The independent variable, 'procedure configuration', had four levels: paper procedures, manual CPS, automation with breaks, and full automation. The results showed that the operators experienced OOTL problems in full automation, but that situation awareness and crew performance (response time) were not affected. One possible explanation for this is that the operators monitored the automated procedure execution conscientiously, something which may have prevented the OOTL problems from having negative effects on situation awareness and crew performance. In a debriefing session, the operators clearly expressed their dislike for the full automation condition, but that automation with breaks could be suitable for some tasks. The main reason why the operators did not like the full automation was that they did not feel being in control. A qualitative analysis addressing factors contributing to response time delays revealed that OOTL problems did not seem to cause delays, but that some delays could be explained by the operators having problems with the freeze function of the CPS. Also other factors such as teamwork and operator tendencies were of importance. Several design implications were drawn

  9. Writer`s guide for technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    A primary objective of operations conducted in the US Department of Energy (DOE) complex is safety. Procedures are a critical element of maintaining a safety envelope to ensure safe facility operation. This DOE Writer`s Guide for Technical Procedures addresses the content, format, and style of technical procedures that prescribe production, operation of equipment and facilities, and maintenance activities. The DOE Writer`s Guide for Management Control Procedures and DOE Writer`s Guide for Emergency and Alarm Response Procedures are being developed to assist writers in developing nontechnical procedures. DOE is providing this guide to assist writers across the DOE complex in producing accurate, complete, and usable procedures that promote safe and efficient operations that comply with DOE orders, including DOE Order 5480.19, Conduct of Operations for DOE Facilities, and 5480.6, Safety of Department of Energy-Owned Nuclear Reactors.

  10. An XML Representation for Crew Procedures

    Science.gov (United States)

    Simpson, Richard C.

    2005-01-01

    NASA ensures safe operation of complex systems through the use of formally-documented procedures, which encode the operational knowledge of the system as derived from system experts. Crew members use procedure documentation on the ground for training purposes and on-board space shuttle and space station to guide their activities. Investigators at JSC are developing a new representation for procedures that is content-based (as opposed to display-based). Instead of specifying how a procedure should look on the printed page, the content-based representation will identify the components of a procedure and (more importantly) how the components are related (e.g., how the activities within a procedure are sequenced; what resources need to be available for each activity). This approach will allow different sets of rules to be created for displaying procedures on a computer screen, on a hand-held personal digital assistant (PDA), verbally, or on a printed page, and will also allow intelligent reasoning processes to automatically interpret and use procedure definitions. During his NASA fellowship, Dr. Simpson examined how various industries represent procedures (also called business processes or workflows), in areas such as manufacturing, accounting, shipping, or customer service. A useful method for designing and evaluating workflow representation languages is by determining their ability to encode various workflow patterns, which depict abstract relationships between the components of a procedure removed from the context of a specific procedure or industry. Investigators have used this type of analysis to evaluate how well-suited existing workflow representation languages are for various industries based on the workflow patterns that commonly arise across industry-specific procedures. Based on this type of analysis, it is already clear that existing workflow representations capture discrete flow of control (i.e., when one activity should start and stop based on when other

  11. Procedural learning and dyslexia.

    Science.gov (United States)

    Nicolson, R I; Fawcett, A J; Brookes, R L; Needle, J

    2010-08-01

    Three major 'neural systems', specialized for different types of information processing, are the sensory, declarative, and procedural systems. It has been proposed (Trends Neurosci., 30(4), 135-141) that dyslexia may be attributable to impaired function in the procedural system together with intact declarative function. We provide a brief overview of the increasing evidence relating to the hypothesis, noting that the framework involves two main claims: first that 'neural systems' provides a productive level of description avoiding the underspecificity of cognitive descriptions and the overspecificity of brain structural accounts; and second that a distinctive feature of procedural learning is its extended time course, covering from minutes to months. In this article, we focus on the second claim. Three studies-speeded single word reading, long-term response learning, and overnight skill consolidation-are reviewed which together provide clear evidence of difficulties in procedural learning for individuals with dyslexia, even when the tasks are outside the literacy domain. The educational implications of the results are then discussed, and in particular the potential difficulties that impaired overnight procedural consolidation would entail. It is proposed that response to intervention could be better predicted if diagnostic tests on the different forms of learning were first undertaken. 2010 John Wiley & Sons, Ltd.

  12. Bio-Oil Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Bio-Oil Analysis Laboratory Procedures Bio-Oil Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for the analysis of raw and upgraded pyrolysis bio-oils. These standard procedures have been validated and allow for reliable bio-oil analysis. Procedures Determination

  13. Surgeon-patient communication during awake procedures.

    Science.gov (United States)

    Smith, Claire S; Guyton, Kristina; Pariser, Joseph J; Siegler, Mark; Schindler, Nancy; Langerman, Alexander

    2017-06-01

    Surgeons are increasingly performing procedures on awake patients. Communication during such procedures is complex and underexplored in the literature. Surgeons were recruited from the faculty of 2 hospitals to participate in an interview regarding their approaches to communication during awake procedures. Three researchers used the constant comparative method to transcribe, code, and review interviews until saturation was reached. Twenty-three surgeons described the advantages and disadvantages of awake procedures, their communication with the awake patient, their interactions with staff and with trainees, the environment of awake procedures, and how communication in this context is taught and learned. Surgeons recognized communication during awake procedures as important and reported varied strategies for ensuring patient comfort in this context. However, they also acknowledged challenges with multiparty communication during awake procedures, especially in balancing commitments to teaching with their duty to comfort the patient. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Robot-assisted procedures in pediatric neurosurgery.

    Science.gov (United States)

    De Benedictis, Alessandro; Trezza, Andrea; Carai, Andrea; Genovese, Elisabetta; Procaccini, Emidio; Messina, Raffaella; Randi, Franco; Cossu, Silvia; Esposito, Giacomo; Palma, Paolo; Amante, Paolina; Rizzi, Michele; Marras, Carlo Efisio

    2017-05-01

    OBJECTIVE During the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population. METHODS Between 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging. RESULTS The authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications. CONCLUSIONS To the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical

  15. Maintenance procedure upgrade programs

    International Nuclear Information System (INIS)

    Campbell, J.J.; Zimmerman, C.M.

    1988-01-01

    This paper describes a systematic approach to upgrading nuclear power plant maintenance procedures. The approach consists of four phases: diagnosis, program planning, program implementation, and program evaluation. Each phase is explained as a series of steps to ensure that all factors in a procedure upgrade program are considered

  16. Coding for urologic office procedures.

    Science.gov (United States)

    Dowling, Robert A; Painter, Mark

    2013-11-01

    This article summarizes current best practices for documenting, coding, and billing common office-based urologic procedures. Topics covered include general principles, basic and advanced urologic coding, creation of medical records that support compliant coding practices, bundled codes and unbundling, global periods, modifiers for procedure codes, when to bill for evaluation and management services during the same visit, coding for supplies, and laboratory and radiology procedures pertinent to urology practice. Detailed information is included for the most common urology office procedures, and suggested resources and references are provided. This information is of value to physicians, office managers, and their coding staff. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Radiochemical procedures

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    The modern counting instrumentation has largely obviated the need for separation processes in the radiochemical analysis but problems in low-level radioactivity measurement, environmental-type analyses, and special situations caused in the last years a renaissance of the need for separation techniques. Most of the radiochemical procedures, based on the classic works of the Manhattan Project chemists of the 1940's, were published in the National Nuclear Energy Series (NNES). Improvements such as new solvent extraction and ion exchange separations have been added to these methods throughout the years. Recently the Los Alamos Group have reissued their collected Radiochemical Procedures containing a short summary and review of basic inorganic chemistry - 'Chemistry of the Elements on the Basis of Electronic Configuration'. (A.L.)

  18. How does the workload and work activities of procedural GPs compare to non-procedural GPs?

    Science.gov (United States)

    Russell, Deborah J; McGrail, Matthew R

    2017-08-01

    To investigate patterns of Australian GP procedural activity and associations with: geographical remoteness and population size hours worked in hospitals and in total; and availability for on-call DESIGN AND PARTICIPANTS: National annual panel survey (Medicine in Australia: Balancing Employment and Life) of Australian GPs, 2011-2013. Self-reported geographical work location, hours worked in different settings, and on-call availability per usual week, were analysed against GP procedural activity in anaesthetics, obstetrics, surgery or emergency medicine. Analysis of 9301 survey responses from 4638 individual GPs revealed significantly increased odds of GP procedural activity in anaesthetics, obstetrics or emergency medicine as geographical remoteness increased and community population size decreased, albeit with plateauing of the effect-size from medium-sized (population 5000-15 000) rural communities. After adjusting for confounders, procedural GPs work more hospital and more total hours each week than non-procedural GPs. In 2011 this equated to GPs practising anaesthetics, obstetrics, surgery, and emergency medicine providing 8% (95%CI 0, 16), 13% (95%CI 8, 19), 8% (95%CI 2, 15) and 18% (95%CI 13, 23) more total hours each week, respectively. The extra hours are attributable to longer hours worked in hospital settings, with no reduction in private consultation hours. Procedural GPs also carry a significantly higher burden of on-call. The longer working hours and higher on-call demands experienced by rural and remote procedural GPs demand improved solutions, such as changes to service delivery models, so that long-term procedural GP careers are increasingly attractive to current and aspiring rural GPs. © 2016 National Rural Health Alliance Inc.

  19. Impact of Sample Type and DNA Isolation Procedure on Genomic Inference of Microbiome Composition

    DEFF Research Database (Denmark)

    Knudsen, Berith Elkær; Bergmark, Lasse; Munk, Patrick

    2016-01-01

    that in standard protocols. Based on this insight, we designed an improved DNA isolation procedure optimized for microbiome genomics that can be used for the three examined specimen types and potentially also for other biological specimens. A standard operating procedure is available from https://dx.doi.org/10......Explorations of complex microbiomes using genomics greatly enhance our understanding about their diversity, biogeography, and function. The isolation of DNA from microbiome specimens is a key prerequisite for such examinations, but challenges remain in obtaining sufficient DNA quantities required...... for certain sequencing approaches, achieving accurate genomic inference of microbiome composition, and facilitating comparability of findings across specimen types and sequencing projects. These aspects are particularly relevant for the genomics-based global surveillance of infectious agents and antimicrobial...

  20. The Influence of Parent Preprocedural Anxiety on Child Procedural Pain: Mediation by Child Procedural Anxiety

    OpenAIRE

    Bearden, Donald J.; Feinstein, Amanda; Cohen, Lindsey L.

    2012-01-01

    Objective Data suggest parents’ preprocedural anxiety is related to children's acute procedural anxiety and pain. This study examined the temporal relations among these constructs to determine whether children's anxiety mediates the relation between parents' anticipatory anxiety and children's procedural pain. Methods A total of 90 preschoolers receiving immunizations, their parents, and the nurses rated children's procedural anxiety and pain. Parents provided ratings of their own preprocedur...

  1. Safety analysis procedures for PHWR

    International Nuclear Information System (INIS)

    Min, Byung Joo; Kim, Hyoung Tae; Yoo, Kun Joong

    2004-03-01

    The methodology of safety analyses for CANDU reactors in Canada, a vendor country, uses a combination of best-estimate physical models and conservative input parameters so as to minimize the uncertainty of the plant behavior predictions. As using the conservative input parameters, the results of the safety analyses are assured the regulatory requirements such as the public dose, the integrity of fuel and fuel channel, the integrity of containment and reactor structures, etc. However, there is not the comprehensive and systematic procedures for safety analyses for CANDU reactors in Korea. In this regard, the development of the safety analyses procedures for CANDU reactors is being conducted not only to establish the safety analyses system, but also to enhance the quality assurance of the safety assessment. In the first phase of this study, the general procedures of the deterministic safety analyses are developed. The general safety procedures are covered the specification of the initial event, selection of the methodology and accident sequences, computer codes, safety analysis procedures, verification of errors and uncertainties, etc. Finally, These general procedures of the safety analyses are applied to the Large Break Loss Of Coolant Accident (LBLOCA) in Final Safety Analysis Report (FSAR) for Wolsong units 2, 3, 4

  2. Handbook of radiologic procedures

    International Nuclear Information System (INIS)

    Hedgcock, M.

    1986-01-01

    This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography

  3. Characteristics of Mobile Payment Procedures

    OpenAIRE

    Kreyer, Nina; Pousttchi, Key; Turowski, Klaus

    2002-01-01

    Companies are not going to invest into the development of innovative applications or services unless these can be charged for appropriately. Thus, the existence of standardized and widely accepted mobile payment procedures is crucial for successful business-to-customer mobile commerce. The acceptance of mobile payment procedures depends on costs, security and convenience issues. For the latter, it is important that a procedure can be used over the different payment scenarios mobile commerce, ...

  4. [Knapp procedure and modified Knapp procedure with Foster suture for the treatment of double elevator palsy].

    Science.gov (United States)

    Li, Y P; Zhang, W; Ding, J; Ma, H Z; Zhao, K X

    2017-12-11

    Objective: To investigate the efficacy of Knapp procedure and modified Knapp procedure with Foster suture in the treatment of double elevator palsy(DEP). Methods: Retrospective study. Twenty-two patients with congenital DEP were underwent Knapp procedure ( n= 15) and modified Knapp procedure( n= 7). The clinical data were retrospectively analyzed, including the preoperative and postoperative vertical deviation in the primary position, ocular motility, and binocular vision. Results: The average vertical deviation in the primary position was (34.7±8.6) prism diopters(PD) before surgery and (6.5±6.5) PD after surgery ( t= 30.41, P= 0.00) in the group underwent Knapp procedure. The mean preoperative and postoperative deviations of the group underwent modified procedure were respectively (38.6±14.6) PD and (5.7±9.3)PD ( t= 15.33, P= 0.00). The mean corrected vertical deviation of the latter (32.8±5.7) PD was greater than that of the former (28.1±3.6) PD( t=- 2.39, P= 0.03). The mean improved upgaze in the modified group (2.6±0.5) was more obvious than that in the Knapp group (1.9±0.6) ( t= 2.41, P= 0.02). There is no significant difference in the surgical effect on downgaze between two groups ( U =43.00, P= 0.54). Seven patients having binocular vision with abnormal head posture (AHP) before surgery obtained binocular single vision in the primary position and reading position after operations. AHP disappeared or reduced to less than 5°. The surgical outcomes were satisfied in 72.7% patients. But the patients with ≥40 PD preoperative vertical deviation were under-corrected and needed the further operations. Conclusions: Knapp procedure and modified Knapp procedure with Foster suture were the efficient procedures for treatment of DEP without restriction of ipsilateral inferior rectus. Both procedures can obviously correct the vertical deviation and improve upgaze without remarkable limitation of downgaze, which is good to obtain the binocular single vision in

  5. Biomass Compositional Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Biomass Compositional Analysis Laboratory Procedures Biomass Compositional Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for standard biomass analysis. These procedures help scientists and analysts understand more about the chemical composition of raw biomass

  6. Procedures For Microbial-Ecology Laboratory

    Science.gov (United States)

    Huff, Timothy L.

    1993-01-01

    Microbial Ecology Laboratory Procedures Manual provides concise and well-defined instructions on routine technical procedures to be followed in microbiological laboratory to ensure safety, analytical control, and validity of results.

  7. TMACS Test Procedure TP002: Trending

    International Nuclear Information System (INIS)

    Scanlan, P.K.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS Trending functions

  8. Operative vaginal delivery and invasive procedures in pregnancy among women living with HIV.

    Science.gov (United States)

    Peters, Helen; Francis, Kate; Harding, Kate; Tookey, Pat A; Thorne, Claire

    2017-03-01

    To describe the use and outcomes of operative delivery and invasive procedures in pregnancy amongst women living with HIV. The National Study of HIV in Pregnancy and Childhood (NSHPC) is a comprehensive population-based surveillance study in the UK and Ireland. The NSHPC has collected data on operative delivery since 2008, and invasive procedures in pregnancy (amniocentesis, cordocentesis, chorionic villus sampling) from 2012. Descriptive analyses were conducted on 278 pregnancies expected to deliver from 1 January 2008 with outcome reported to the NSHPC by 31 March 2016. Among 9372 pregnancies in 2008-2016, there were 9072 livebirths with 251 operative deliveries and 27 invasive procedures in pregnancy reported. Information was available for 3023/3490 vaginal deliveries, and use of forceps or vacuum reported in 251deliveries (8.2%), increasing over calendar time to almost 10% by 2014-16. Forceps were used twice as often as vacuum delivery, and forceps use increased over time. One infant delivered operatively is known to have acquired HIV. From 2012 there were 4063 pregnancies resulting in 3952 livebirths, 83 terminations and 28 stillbirths. 2163/4063 had information on use (or not) of invasive procedures in pregnancy. Amniocentesis was reported in 25/2163 pregnancies, there was one report of chorionic villus sampling and one of cordocentesis. There were no reported transmissions following invasive procedures in pregnancy. This is the largest study to date to report on operative delivery in women living with HIV on combined antiretroviral therapy (cART), and provides an up-to-date picture of invasive procedures during pregnancy in this group. Findings from this comprehensive national study are reassuring but numbers are currently low; on-going monitoring is crucial as obstetric care of women with HIV becomes normalised. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Evaluation of Flight Deck-Based Interval Management Crew Procedure Feasibility

    Science.gov (United States)

    Wilson, Sara R.; Murdoch, Jennifer L.; Hubbs, Clay E.; Swieringa, Kurt A.

    2013-01-01

    Air traffic demand is predicted to increase over the next 20 years, creating a need for new technologies and procedures to support this growth in a safe and efficient manner. The National Aeronautics and Space Administration's (NASA) Air Traffic Management Technology Demonstration - 1 (ATD-1) will operationally demonstrate the feasibility of efficient arrival operations combining ground-based and airborne NASA technologies. The integration of these technologies will increase throughput, reduce delay, conserve fuel, and minimize environmental impacts. The ground-based tools include Traffic Management Advisor with Terminal Metering for precise time-based scheduling and Controller Managed Spacing decision support tools for better managing aircraft delay with speed control. The core airborne technology in ATD-1 is Flight deck-based Interval Management (FIM). FIM tools provide pilots with speed commands calculated using information from Automatic Dependent Surveillance - Broadcast. The precise merging and spacing enabled by FIM avionics and flight crew procedures will reduce excess spacing buffers and result in higher terminal throughput. This paper describes a human-in-the-loop experiment designed to assess the acceptability and feasibility of the ATD-1 procedures used in a voice communications environment. This experiment utilized the ATD-1 integrated system of ground-based and airborne technologies. Pilot participants flew a high-fidelity fixed base simulator equipped with an airborne spacing algorithm and a FIM crew interface. Experiment scenarios involved multiple air traffic flows into the Dallas-Fort Worth Terminal Radar Control airspace. Results indicate that the proposed procedures were feasible for use by flight crews in a voice communications environment. The delivery accuracy at the achieve-by point was within +/- five seconds and the delivery precision was less than five seconds. Furthermore, FIM speed commands occurred at a rate of less than one per minute

  10. Summative Mass Analysis of Algal Biomass - Integration of Analytical Procedures: Laboratory Analytical Procedure (LAP)

    Energy Technology Data Exchange (ETDEWEB)

    Laurens, Lieve M. L.

    2016-01-13

    This procedure guides the integration of laboratory analytical procedures to measure algal biomass constituents in an unambiguous manner and ultimately achieve mass balance closure for algal biomass samples. Many of these methods build on years of research in algal biomass analysis.

  11. Relations among conceptual knowledge, procedural knowledge, and procedural flexibility in two samples differing in prior knowledge.

    Science.gov (United States)

    Schneider, Michael; Rittle-Johnson, Bethany; Star, Jon R

    2011-11-01

    Competence in many domains rests on children developing conceptual and procedural knowledge, as well as procedural flexibility. However, research on the developmental relations between these different types of knowledge has yielded unclear results, in part because little attention has been paid to the validity of the measures or to the effects of prior knowledge on the relations. To overcome these problems, we modeled the three constructs in the domain of equation solving as latent factors and tested (a) whether the predictive relations between conceptual and procedural knowledge were bidirectional, (b) whether these interrelations were moderated by prior knowledge, and (c) how both constructs contributed to procedural flexibility. We analyzed data from 2 measurement points each from two samples (Ns = 228 and 304) of middle school students who differed in prior knowledge. Conceptual and procedural knowledge had stable bidirectional relations that were not moderated by prior knowledge. Both kinds of knowledge contributed independently to procedural flexibility. The results demonstrate how changes in complex knowledge structures contribute to competence development.

  12. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  13. Designing Flightdeck Procedures: Literature Resources

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel; Degani, Asaf; Loukopoulou, Loukia; Mauro, Robert

    2017-01-01

    This technical publication contains the titles, abstracts, summaries, descriptions, and/or annotations of available literature sources on procedure design and development, requirements, and guidance. It is designed to provide users with an easy access to available resources on the topic of procedure design, and with a sense of the contents of these sources. This repository of information is organized into the following publication sources: Research (e.g., journal articles, conference proceedings), Manufacturers' (e.g., operation manuals, newsletters), and Regulatory and/or Government (e.g., advisory circulars, reports). An additional section contains synopses of Accident/Incident Reports involving procedures. This work directly supports a comprehensive memorandum by Barshi, Mauro, Degani, & Loukopoulou (2016) that summarizes the results of a multi-year project, partially funded by the FAA, to develop technical reference materials that support guidance on the process of developing cockpit procedures (see "Designing Flightdeck Procedures" https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20160013263.pdf). An extensive treatment of this topic is presented in a forthcoming book by the same authors.

  14. 21 CFR 211.150 - Distribution procedures.

    Science.gov (United States)

    2010-04-01

    ...: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Holding and Distribution § 211.150 Distribution procedures. Written procedures shall be established, and followed, describing the... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Distribution procedures. 211.150 Section 211.150...

  15. Guide for environmental radiological surveillance at ERDA installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Denham, D.H.; Michels, D.E.; Olsen, A.R.; Waite, D.A.

    1977-03-01

    This Guide is intended to: Provide recommended methods, procedures, and performance criteria to bring greater comparability to ERDA environmental monitoring and reporting systems; provide ERDA management, particularly the Headquarters' Division of Safety, Standards, and Compliance (SSC) and field offices, with a broad review of accepted radiological surveillance practices for use in the evaluation of environmental surveillance programs at ERDA facilities; and delineate the capabilities and limitations of the various environmental monitoring systems for radioactivity currently used at ERDA sites, including technical areas where there is either an inadequate basis for procedural selection or where further developmental work may be warranted. The discussion of equipment, measurement techniques, and quality control procedures, although believed to represent current technology, is subject to continuing change as technological improvements become available

  16. Pre-procedural antibiotics for endoscopic urological procedures: Initial experience in individuals with spinal cord injury and asymptomatic bacteriuria.

    Science.gov (United States)

    Chong, Julio T; Klausner, Adam P; Petrossian, Albert; Byrne, Michael D; Moore, Jewel R; Goetz, Lance L; Gater, David R; Grob, B Mayer

    2015-03-01

    The objective of this study was to compare the safety, efficacy, quality-of-life impact, and costs of a single dose or a longer course of pre-procedural antibiotics prior to elective endoscopic urological procedures in individuals with spinal cord injury and disorders (SCI/D) and asymptomatic bacteriuria. A prospective observational study. Hunter Holmes McGuire Veterans Affairs Medical Center, Richmond, Virginia, USA. Sixty persons with SCI/D and asymptomatic bacteriuria scheduled to undergo elective endoscopic urological procedures. A single pre-procedural dose of antibiotics vs. a 3-5-day course of pre-procedural antibiotics. Objective and subjective measures of health, costs, and quality of life. There were no significant differences in vital signs, leukocytosis, adverse events, and overall satisfaction in individuals who received short-course vs. long-course antibiotics. There was a significant decrease in antibiotic cost (33.1 ± 47.6 vs. 3.6 ± 6.1 US$, P = 0.01) for individuals in the short-course group. In addition, there was greater pre-procedural anxiety (18 vs. 0%, P antibiotics. SCI/D individuals with asymptomatic bacteriuria may be able to safely undergo most endoscopic urological procedures with a single dose of pre-procedural antibiotics. However, further research is required and even appropriate pre-procedural antibiotics may not prevent severe infections.

  17. Automatic segmentation of rotational x-ray images for anatomic intra-procedural surface generation in atrial fibrillation ablation procedures.

    Science.gov (United States)

    Manzke, Robert; Meyer, Carsten; Ecabert, Olivier; Peters, Jochen; Noordhoek, Niels J; Thiagalingam, Aravinda; Reddy, Vivek Y; Chan, Raymond C; Weese, Jürgen

    2010-02-01

    Since the introduction of 3-D rotational X-ray imaging, protocols for 3-D rotational coronary artery imaging have become widely available in routine clinical practice. Intra-procedural cardiac imaging in a computed tomography (CT)-like fashion has been particularly compelling due to the reduction of clinical overhead and ability to characterize anatomy at the time of intervention. We previously introduced a clinically feasible approach for imaging the left atrium and pulmonary veins (LAPVs) with short contrast bolus injections and scan times of approximately 4 -10 s. The resulting data have sufficient image quality for intra-procedural use during electro-anatomic mapping (EAM) and interventional guidance in atrial fibrillation (AF) ablation procedures. In this paper, we present a novel technique to intra-procedural surface generation which integrates fully-automated segmentation of the LAPVs for guidance in AF ablation interventions. Contrast-enhanced rotational X-ray angiography (3-D RA) acquisitions in combination with filtered-back-projection-based reconstruction allows for volumetric interrogation of LAPV anatomy in near-real-time. An automatic model-based segmentation algorithm allows for fast and accurate LAPV mesh generation despite the challenges posed by image quality; relative to pre-procedural cardiac CT/MR, 3-D RA images suffer from more artifacts and reduced signal-to-noise. We validate our integrated method by comparing 1) automatic and manual segmentations of intra-procedural 3-D RA data, 2) automatic segmentations of intra-procedural 3-D RA and pre-procedural CT/MR data, and 3) intra-procedural EAM point cloud data with automatic segmentations of 3-D RA and CT/MR data. Our validation results for automatically segmented intra-procedural 3-D RA data show average segmentation errors of 1) approximately 1.3 mm compared with manual 3-D RA segmentations 2) approximately 2.3 mm compared with automatic segmentation of pre-procedural CT/MR data and 3

  18. Analytical procedures. Pt. 1

    International Nuclear Information System (INIS)

    Weber, G.

    1985-01-01

    In analytical procedures (Boole procedures) there is certain to be a close relationship between the safety assessment and reliability assessment of technical facilities. The paper gives an overview of the organization of models, fault trees, the probabilistic evaluation of systems, evaluation with minimum steps or minimum paths regarding statistically dependent components and of systems liable to suffer different kinds of outages. (orig.) [de

  19. 46 CFR 154.665 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Welding procedures. 154.665 Section 154.665 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS... Construction § 154.665 Welding procedures. Welding procedure tests for cargo tanks for a design temperature...

  20. 49 CFR 192.225 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  1. 40 CFR 1065.10 - Other procedures.

    Science.gov (United States)

    2010-07-01

    ... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures, such as those of the California Air Resources Board or the International Organization for... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Other procedures. 1065.10 Section 1065...

  2. 40 CFR 205.54 - Test procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test procedures. 205.54 Section 205.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54 Test procedures. The procedures described...

  3. Assessing mental workload and situation awareness in the evaluation of computerized procedures in the main control room

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chih-Wei, E-mail: yangcw@iner.gov.tw [Institute of Nuclear Energy Research, 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Yang, Li-Chen; Cheng, Tsung-Chieh [Institute of Nuclear Energy Research, 1000, Wenhua Rd., Jiaan Village, Longtan Township, Taoyuan County 32546, Taiwan (China); Jou, Yung-Tsan; Chiou, Shian-Wei [Department of Industrial Engineering, Chung-Yuan Christian University, 200, Chung Pei Rd., Chung-Li 32023, Taiwan (China)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer This study investigates procedure types' effects on operators' performance. Black-Right-Pointing-Pointer The computer-based procedure is suggested to be implemented in the main control room. Black-Right-Pointing-Pointer The computer-based procedure brings lowest mental workload. Black-Right-Pointing-Pointer And it also generates fewer error of omission, and the highest situation awareness. Black-Right-Pointing-Pointer The shift supervisor has the highest workload and the lowest situation awareness. - Abstract: Computerized procedure (CP) system has been developed in nuclear power plant (NPP) instrumentation and control (I and C) system. The system may include normal operating procedures (OPs), abnormal operating procedures (AOPs), alarm response procedures (ARPs), surveillance test procedures (STPs) and/or emergency operating procedures (EOPs). While there are many ways to evaluate computerized procedures design, the user's mental workload and situation awareness (SA) are particularly important considerations in the supervisory control of safety-critical systems. Users' mental workload and situation awareness may be influenced by human factor issues relating to computerized procedures, e.g., level of automation, dealing with (partially) unavailable I and C, switching to back-up system (e.g., paper-based procedures). Some of the positive impacts of CPs on operator performance include the following: tasks can be performed more quickly; overall workload can be reduced; cognitive workload can be minimized; fewer errors may be made in transitioning through or between procedures. However, various challenges have also been identified with CP systems. These should be addressed in the design and implementation of CPs where they are applicable. For example, narrower 'field of view' provided by CP systems than with paper-based procedures could reduce crew communications and crewmember awareness of the

  4. Assessing mental workload and situation awareness in the evaluation of computerized procedures in the main control room

    International Nuclear Information System (INIS)

    Yang, Chih-Wei; Yang, Li-Chen; Cheng, Tsung-Chieh; Jou, Yung-Tsan; Chiou, Shian-Wei

    2012-01-01

    Highlights: ► This study investigates procedure types’ effects on operators’ performance. ► The computer-based procedure is suggested to be implemented in the main control room. ► The computer-based procedure brings lowest mental workload. ► And it also generates fewer error of omission, and the highest situation awareness. ► The shift supervisor has the highest workload and the lowest situation awareness. - Abstract: Computerized procedure (CP) system has been developed in nuclear power plant (NPP) instrumentation and control (I and C) system. The system may include normal operating procedures (OPs), abnormal operating procedures (AOPs), alarm response procedures (ARPs), surveillance test procedures (STPs) and/or emergency operating procedures (EOPs). While there are many ways to evaluate computerized procedures design, the user's mental workload and situation awareness (SA) are particularly important considerations in the supervisory control of safety-critical systems. Users’ mental workload and situation awareness may be influenced by human factor issues relating to computerized procedures, e.g., level of automation, dealing with (partially) unavailable I and C, switching to back-up system (e.g., paper-based procedures). Some of the positive impacts of CPs on operator performance include the following: tasks can be performed more quickly; overall workload can be reduced; cognitive workload can be minimized; fewer errors may be made in transitioning through or between procedures. However, various challenges have also been identified with CP systems. These should be addressed in the design and implementation of CPs where they are applicable. For example, narrower “field of view” provided by CP systems than with paper-based procedures could reduce crew communications and crewmember awareness of the status and progress through the procedure. Based on a human factors experiment in which each participant monitored and controlled multiple simulated

  5. Procedures minimally invasive image-guided

    International Nuclear Information System (INIS)

    Mora Guevara, Alejandro

    2011-01-01

    A literature review focused on minimally invasive procedures, has been performed at the Department of Radiology at the Hospital Calderon Guardia. A multidisciplinary team has been raised for decision making. The materials, possible complications and the available imaging technique such as ultrasound, computed tomography, magnetic resonance imaging, have been determined according to the procedure to be performed. The revision has supported medical interventions didactically enjoying the best materials, resources and conditions for a successful implementation of procedures and results [es

  6. Preschooler test or procedure preparation

    Science.gov (United States)

    ... your child during and after the procedure with books, songs, counting, deep breathing, or blowing bubbles. PLAY ... can be present during the procedure. Ask if anesthesia can be used to reduce your child's discomfort. ...

  7. Toddler test or procedure preparation

    Science.gov (United States)

    ... a test or procedure: Explain the procedure in language your child understands, using plain words. Avoid abstract terms. Make sure your child understands the exact body part involved in the test, and that the ...

  8. Fusion Imaging for Procedural Guidance.

    Science.gov (United States)

    Wiley, Brandon M; Eleid, Mackram F; Thaden, Jeremy J

    2018-05-01

    The field of percutaneous structural heart interventions has grown tremendously in recent years. This growth has fueled the development of new imaging protocols and technologies in parallel to help facilitate these minimally-invasive procedures. Fusion imaging is an exciting new technology that combines the strength of 2 imaging modalities and has the potential to improve procedural planning and the safety of many commonly performed transcatheter procedures. In this review we discuss the basic concepts of fusion imaging along with the relative strengths and weaknesses of static vs dynamic fusion imaging modalities. This review will focus primarily on echocardiographic-fluoroscopic fusion imaging and its application in commonly performed transcatheter structural heart procedures. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  9. Considerable variability of procedural sedation and analgesia practices for gastrointestinal endoscopic procedures in Europe

    NARCIS (Netherlands)

    Vaessen, Hermanus H B; Knape, Johannes T A

    2016-01-01

    Background/Aims: The use of moderate to deep sedation for gastrointestinal endoscopic procedures has increased in Europe considerably. Because this level of sedation is a risky medical procedure, a number of international guidelines have been developed. This survey aims to review if, and if so

  10. 40 CFR 791.30 - Hearing procedures.

    Science.gov (United States)

    2010-07-01

    ... officer may deem necessary to an understanding and determination of the dispute. The hearing officer shall... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Hearing procedures. 791.30 Section 791... (CONTINUED) DATA REIMBURSEMENT Hearing Procedures § 791.30 Hearing procedures. (a) Representation by counsel...

  11. 28 CFR 79.73 - Appeals procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Appeals procedures. 79.73 Section 79.73 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) CLAIMS UNDER THE RADIATION EXPOSURE COMPENSATION ACT Procedures § 79.73 Appeals procedures. (a) An appeal must be in writing and must be received by...

  12. Automation of the testing procedure

    International Nuclear Information System (INIS)

    Haas, H.; Fleischer, M.; Bachner, E.

    1979-01-01

    For the judgement of technologies applied and the testing of specific components of the HTR primary circuit, complex test procedures and data evaluations are required. Extensive automation of these test procedures is indispensable. (orig.) [de

  13. The nuclear licensing procedure

    International Nuclear Information System (INIS)

    Wagner, H.

    1976-01-01

    To begin with, the present nuclear licensing procedure is illustrated by a diagram. The relationship between the state and the Laender, the various experts (GRS - IRS + LRA -, TUEV, DWD, university institutes, firms of consulting engineers, etc), participation of the public, e.g. publication of the relevant documents, questions, objections (made by individuals or by groups such as citizens' initiatives), public discussion, official notice, appeals against the decision, the right of immediate execution of the decision are shortly dealt with. Finally, ways to improve the licensing procedure are discussed, from the evaluation of the documents to be submitted, published, and examined by the authorities (and their experts) up to an improvement of the administrative procedure. An improved licensing procedure should satisfy the well-founded claims of the public for more transparency as well as the equally justifiable claims of industry and utilities in order to ensure that the citizens' legal right to have safe and adequate electric power is guaranteed. The updated energy programme established by the Federal Government is mentioned along with the effectiveness of dealing with nuclear problems on the various levels of a Land government. (orig.) [de

  14. Revised Unfilling Procedure for Solid Lithium Lenses

    International Nuclear Information System (INIS)

    Leveling, A.

    2003-01-01

    A procedure for unfilling used lithium lenses to has been described in Pbar Note 664. To date, the procedure has been used to disassemble lenses 20, 21, 17, 18, and 16. As a result of this work, some parts of the original procedure were found to be time consuming and ineffective. Modifications to the original procedure have been made to streamline the process and are discussed in this note. The revised procedure is included in this note.

  15. Quality surveillance experience of PHWR fuel

    International Nuclear Information System (INIS)

    Kulkarni, P.G.; Bandyopadhyay, A.K.; Shah, B.K.

    1997-01-01

    Quality Surveillance activities are being carried out for PHWR fuel for over 25 years in India. A large number of fuel bundles of 19 element design have been produced and successfully irradiated. The quality surveillance practices follow the guidelines given in various Quality Assurance Codes and Guides. An independent third party surveillance is provided to cover major manufacturing and quality control operations. A system of design basis review periodic quality audit and regulatory safety review is in place. Over the years there have been modifications in the quality assurance procedures to comply with changing requirements. Also many innovative improvements have been introduced in the manufacturing procedures. Similarly quality control activities are also modified. Developments in fuel has remained a continuous activity. The paper summarizes the experience gathered over many years in this exciting process of innovation and improvement. (author)

  16. Computer-Based Procedures for Field Workers in Nuclear Power Plants: Development of a Model of Procedure Usage and Identification of Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Katya Le Blanc; Johanna Oxstrand

    2012-04-01

    The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use performance, researchers, together with the nuclear industry, have been looking at replacing the current paper-based procedures with computer-based procedure systems. The concept of computer-based procedures is not new by any means; however most research has focused on procedures used in the main control room. Procedures reviewed in these efforts are mainly emergency operating procedures and normal operating procedures. Based on lessons learned for these previous efforts we are now exploring a more unknown application for computer based procedures - field procedures, i.e. procedures used by nuclear equipment operators and maintenance technicians. The Idaho National Laboratory and participants from the U.S. commercial nuclear industry are collaborating in an applied research effort with the objective of developing requirements and specifications for a computer-based procedure system to be used by field workers. The goal is to identify the types of human errors that can be mitigated by using computer-based procedures and how to best design the computer-based procedures to do so. This paper describes the development of a Model of Procedure Use and the qualitative study on which the model is based. The study was conducted in collaboration with four nuclear utilities and five research institutes. During the qualitative study and the model development requirements and for computer-based procedures were identified.

  17. WSSDA's Guide to Parliamentary Procedures. Revised

    Science.gov (United States)

    Randolph, Mary

    2004-01-01

    This guide to parliamentary procedures is presented by the Washington State School Directors' Association (WSSDA) for use by local school boards within the State of Washington. Parliamentary law and parliamentary procedure is the key to order and to provide justice and fairness to all. Through both formal and informal parliamentary procedures,…

  18. 39 CFR 5.2 - Committee procedure.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Committee procedure. 5.2 Section 5.2 Postal Service UNITED STATES POSTAL SERVICE THE BOARD OF GOVERNORS OF THE U.S. POSTAL SERVICE COMMITTEES (ARTICLE V) § 5.2 Committee procedure. Each committee establishes its own rules of procedure, consistent with...

  19. Intake Procedures in College Counseling Centers.

    Science.gov (United States)

    Pappas, James P.; And Others

    Intake procedures is the common subject of four papers presented in this booklet. James P. Pappas discusses trends, a decision theory model, information and issues in his article "Intake Procedures in Counseling Centers--Trends and Theory." In the second article "The Utilization of Standardized Tests in Intake Procedures or 'Where's the Post…

  20. 49 CFR 195.214 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 195.214 Section 195.214... PIPELINE Construction § 195.214 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures qualified under Section 5 of API 1104 or Section IX of the ASME Boiler and...

  1. Deterministic effects of interventional radiology procedures

    International Nuclear Information System (INIS)

    Shope, Thomas B.

    1997-01-01

    The purpose of this paper is to describe deterministic radiation injuries reported to the Food and Drug Administration (FDA) that resulted from therapeutic, interventional procedures performed under fluoroscopic guidance, and to investigate the procedure or equipment-related factors that may have contributed to the injury. Reports submitted to the FDA under both mandatory and voluntary reporting requirements which described radiation-induced skin injuries from fluoroscopy were investigated. Serious skin injuries, including moist desquamation and tissues necrosis, have occurred since 1992. These injuries have resulted from a variety of interventional procedures which have required extended periods of fluoroscopy compared to typical diagnostic procedures. Facilities conducting therapeutic interventional procedures need to be aware of the potential for patient radiation injury and take appropriate steps to limit the potential for injury. (author)

  2. Complex intravenous anesthesia in interventional procedures

    International Nuclear Information System (INIS)

    Xie Zonggui; Hu Yuanming; Huang Yunlong; You Yong; Wu Juan; Huang Zengping; Li Jian

    2006-01-01

    Objective: To evaluate the value and safety of Diprivan and Fentany intravenous administration of analgesia in interventional procedures. Methods: Diprivan with Fentany intravenous administration for analgesia was used in eighty interventional procedures of sixty-five patients, without tracheal tube insertion. Vital signs including HR, BP, arterial oxygen saturation (SpO 2 ) and patients' reaction to operating were recorded. Results: Intravenous anesthesia was cared out successfully in eighty interventional procedures, with patients under sleeping condition during the operation, together with no pain and no agony memory of the procedure. The amount of Diprivan was 500±100 mg and Fentany was 0.2±0.025 mg. Mean arterial pressure and SpO 2 were 11.4±2.2 kPa, 10.6±2.1 kPa and 98±1.0, 96±1.5 respectively before and after ten minutes of the operation, with no significant difference. Conclusions: Diprivan with Fentany intravenous administration for interventional procedure analgesia possess good safety, painless and no agony memory of the procedure; therefor ought to be recommended. (authors)

  3. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection.

    Science.gov (United States)

    Martin, Douglas J; Rad, Arash Ehteshami; Kallmes, David F

    2012-06-01

    Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, postprocedure plain radiographs, and postprocedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and prevertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ(2) test. One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34%, 95% CI 28-42%) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P = 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n = 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and prevertebral venous (n = 32, 18%, 95% CI 13-24%). Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography.

  4. An improved ashing procedure for biologic sample

    Energy Technology Data Exchange (ETDEWEB)

    Zongmei, Wu [Zhejiang Province Enviromental Radiation Monitoring Centre (China)

    1992-07-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches.

  5. An improved ashing procedure for biologic sample

    International Nuclear Information System (INIS)

    Wu Zongmei

    1992-01-01

    The classical ashing procedure in muffle was modified for biologic samples. In the modified procedure the door of muffle was open in the duration of ashing process, the ashing was accelerated and the ashing product quality was comparable to that the classical procedure. The modified procedure is suitable for ashing biologic samples in large batches

  6. Series expansion of the modified Einstein Procedure

    Science.gov (United States)

    Seema Chandrakant Shah-Fairbank

    2009-01-01

    This study examines calculating total sediment discharge based on the Modified Einstein Procedure (MEP). A new procedure based on the Series Expansion of the Modified Einstein Procedure (SEMEP) has been developed. This procedure contains four main modifications to MEP. First, SEMEP solves the Einstein integrals quickly and accurately based on a series expansion. Next,...

  7. Nuclear materials management procedures

    International Nuclear Information System (INIS)

    Veevers, K.; Silver, J.M.; Quealy, K.J.; Steege, E. van der.

    1987-10-01

    This manual describes the procedures for the management of nuclear materials and associated materials at the Lucas Heights Research Laboratories. The procedures are designed to comply with Australia's nuclear non-proliferation obligations to the International Atomic Energy Agency (IAEA), bilateral agreements with other countries and ANSTO's responsibilities under the Nuclear Non-Proliferation (Safeguards) Act, 1987. The manual replaces those issued by the Australian Atomic Energy Commission in 1959, 1960 and 1969

  8. Objective Truth Institution in Criminal Procedure

    Directory of Open Access Journals (Sweden)

    Voltornist O. A.

    2012-11-01

    Full Text Available The article deals with the category of objective truth in criminal procedure, its importance for correct determination of criminal court procedure aims. The author analyzes also the bill draft offered by the RF Committee of Inquiry “On amending in the RF Criminal Procedure Code due to the implementation ofobjective truth institution in criminal procedure”

  9. Procedures for sampling radium-contaminated soils

    International Nuclear Information System (INIS)

    Fleischhauer, H.L.

    1985-10-01

    Two procedures for sampling the surface layer (0 to 15 centimeters) of radium-contaminated soil are recommended for use in remedial action projects. Both procedures adhere to the philosophy that soil samples should have constant geometry and constant volume in order to ensure uniformity. In the first procedure, a ''cookie cutter'' fashioned from pipe or steel plate, is driven to the desired depth by means of a slide hammer, and the sample extracted as a core or plug. The second procedure requires use of a template to outline the sampling area, from which the sample is obtained using a trowel or spoon. Sampling to the desired depth must then be performed incrementally. Selection of one procedure over the other is governed primarily by soil conditions, the cookie cutter being effective in nongravelly soils, and the template procedure appropriate for use in both gravelly and nongravelly soils. In any event, a minimum sample volume of 1000 cubic centimeters is recommended. The step-by-step procedures are accompanied by a description of the minimum requirements for sample documentation. Transport of the soil samples from the field is then addressed in a discussion of the federal regulations for shipping radioactive materials. Interpretation of those regulations, particularly in light of their application to remedial action soil-sampling programs, is provided in the form of guidance and suggested procedures. Due to the complex nature of the regulations, however, there is no guarantee that our interpretations of them are complete or entirely accurate. Preparation of soil samples for radium-226 analysis by means of gamma-ray spectroscopy is described

  10. Multiple position borehole extensometer procedure: Final draft

    International Nuclear Information System (INIS)

    1986-08-01

    The purpose of the Multiple Position Borehole Extensometer Procedure is to provide detailed information for MPBXs installed at the salt Deaf Smith County ESF. This procedure includes design of equipment, installation, instructions, instrument locations, measurement requirements, support requirements, quality assurance procedures, and data acquisition requirements. Data reduction procedures are also discussed; however, the relevance of the data is discussed elsewhere in the appropriate test plans. Sufficient detail is provided in this procedure to allow for integrating the requirements of this procedure into both the facility construction and overall underground testing programs; identifying necessary equipment for procurement; determining data acquisition requirements as input to Automatic Data Acquisition System (ADAS) design; providing step-by-step procedures for training personnel as well as for directing field operations; establishing quality assurance (QA) checkpoints and implementation methods; and defining data reduction methods and providing the anticipated accuracy of the system. 11 refs., 14 figs

  11. Failure to Follow Written Procedures

    Science.gov (United States)

    2017-12-01

    Most tasks in aviation have a mandated written procedure to be followed specifically under the Code of Federal Regulations (CFR) Part 14, Section 43.13(a). However, the incidence of Failure to Follow Procedure (FFP) events continues to be a major iss...

  12. 48 CFR 410.002 - Procedures.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Procedures. 410.002 Section 410.002 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE COMPETITION AND ACQUISITION PLANNING MARKET RESEARCH 410.002 Procedures. Market research must include obtaining information on...

  13. Environmental protection and procedural law

    International Nuclear Information System (INIS)

    Mutschler, U.

    1978-01-01

    For the power industry which is 'independent of licensing', the Ule/Laubinger statement as well as its discussion on the 52th German legal experts' day are of considerable importance. It is therefore absolutely necessary to critically investigate the statements of this expert's opinion and the considerations on which they are based. This investigation is limited to those licensing procedures which in the terminology of experts, are 'similar to the plan approval procedure'. This applies mainly to the procedures according to paragraph 4 ff of the Federal Act on the Protection Against Nuisances and paragraph 7 of the Atomic Energy Law: Preliminaries publication of documents, inspection of files, public hearing, taking of evidence, persons with special responsibilities, administrative proceedings, actions by associations. The deficiencies in the execution of environmental procedural law is briefly mentioned. The notes in the article refer only to air pollution. (orig./HP) [de

  14. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  15. Procedures monitoring and MAAP analysis

    International Nuclear Information System (INIS)

    May, R.S.

    1991-01-01

    Numerous studies of severe accidents in light water reactors have shown that operator response can play a crucial role in the predicted outcomes of dominant accident scenarios. MAAP provides the capability to specify certain operator actions as input data. However, making reasonable assumptions about the nature and timing of operator response requires substantial knowledge about plant practices and procedures and what they imply for the event being analyzed. The appearance of knowledge based software technology in the mid-1980s provided a natural format for representing and maintaining procedures as IF-THEN rules. The boiling water reactor (BWR) Emergency Operating Procedures Tracking System (EOPTS) was composed of a rule base of procedures and a dedicated inference engine (problem-solver). Based on the general approach and experience of EOPTS, the authors have developed a prototype procedures monitoring system that reads MAAP transient output files and evaluate the EOP messages and instructions that would be implied during each transient time interval. The prototype system was built using the NEXPERT OBJECT expert system development system, running on a 386-class personal computer with 4 MB of memory. The limited scope prototype includes a reduced set of BWR6 EOPs procedures evaluation on a coarse time interval, a simple text-based user interface, and a summary-report generator. The prototype, which is limited to batch-mode analysis of MAAP output, is intended to demonstrate the concept and aid in the design of a production system, which will involve a direct link to MAAP and interactive capabilities

  16. Environmental Measurements Laboratory (EML) procedures manual

    International Nuclear Information System (INIS)

    Chieco, N.A.; Bogen, D.C.; Knutson, E.O.

    1990-11-01

    Volume 1 of this manual documents the procedures and existing technology that are currently used by the Environmental Measurements Laboratory. A section devoted to quality assurance has been included. These procedures have been updated and revised and new procedures have been added. They include: sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications. 228 refs., 62 figs., 37 tabs. (FL)

  17. PC based temporary shielding administrative procedure (TSAP)

    International Nuclear Information System (INIS)

    Olsen, D.E.; Pederson, G.E.; Hamby, P.N.

    1995-01-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison's six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met

  18. PC based temporary shielding administrative procedure (TSAP)

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.E.; Pederson, G.E. [Sargent & Lundy, Chicago, IL (United States); Hamby, P.N. [Commonwealth Edison Co., Downers Grove, IL (United States)

    1995-03-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.

  19. Implementation of procedures to NPP Krsko INTRANEK

    International Nuclear Information System (INIS)

    Gradisar, D.; Krajnc, M.; Kocnar, R.; Spiler, J.

    1999-01-01

    Part of NEK documentation has already been presented on NEK Intranet such as USAR, Technical Specifications, QA Plan as well as some frequently used series of drawings. At the time being the process of presentation of all procedures (thereinafter INTRANEK procedures) is in progress. The purpose of this project is the presentation of 1600 procedures with average size of 30 pages what is more than 48000 pages altogether. ADOBE PDF (Portable Document Format) has been chosen as the most suitable format for the presentation of procedures on INTRANEK. PDF format meets the following criteria: the outlook of a document page is always the same as an original one and cannot be changed without control. In addition to this, full text search is available as well as easy jump from procedure to procedure. Some changes of working process on internal procedures have to be made before the project start, which determine the responsibility of individual users in the process. The work flow, which enables easy daily maintenance, has been prepared, the rules of both procedure numbering as well as folder contents/name have been set and the server selected. The project was managed and implemented with the extensive use of compute-aided management, document distribution and control, databases, electronics mail and Intranet tools. The results of practical implementation of NEK procedures and our experience with INTRANEK are presented in this paper.(author)

  20. 28 CFR 527.31 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Procedures. 527.31 Section 527.31 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INMATE ADMISSION, CLASSIFICATION, AND TRANSFER TRANSFERS Transfer of Inmates to State Agents for Production on State Writs § 527.31 Procedures...

  1. Procedures for ground-water investigations

    International Nuclear Information System (INIS)

    1992-12-01

    This manual was developed by the Pacific Northwest Laboratory (PNL) to document the procedures used to carry out and control the technical aspects of ground-water investigations at the PNL. Ground-water monitoring procedures are developed and used in accordance with the PNL Quality Assurance Program

  2. Procedural pain in neonatal units in Kenya.

    Science.gov (United States)

    Kyololo, O'Brien Munyao; Stevens, Bonnie; Gastaldo, Denise; Gisore, Peter

    2014-11-01

    To determine the nature and frequency of painful procedures and procedural pain management practices in neonatal units in Kenya. Cross-sectional survey. Level I and level II neonatal units in Kenya. Ninety-five term and preterm neonates from seven neonatal units. Medical records of neonates admitted for at least 24 h were reviewed to determine the nature and frequency of painful procedures performed in the 24 h period preceding data collection (6:00 to 6:00) as well as the pain management interventions (eg, morphine, breastfeeding, skin-to-skin contact, containment, non-nutritive sucking) that accompanied each procedure. Neonates experienced a total of 404 painful procedures over a 24 h period (mean=4.3, SD 2.0; range 1-12); 270 tissue-damaging (mean=2.85, SD 1.1; range 1-6) and 134 non-tissue-damaging procedures (mean=1.41, SD 1.2; range 0-6). Peripheral cannula insertion (27%) and intramuscular injections (22%) were the most common painful procedures. Ventilated neonates and neonates admitted in level II neonatal units had a higher number of painful procedures than those admitted in level I units (mean 4.76 vs 2.96). Only one procedure had a pain intensity score documented; and none had been performed with any form of analgesia. Neonates in Kenya were exposed to numerous tissue-damaging and non-tissue-damaging procedures without any form of analgesia. Our findings suggest that education is needed on how to assess and manage procedural pain in neonatal units in Kenya. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Can proceduralization support coping with the unexpected?

    International Nuclear Information System (INIS)

    Norros, Leena; Savioja, Paula; Liinasuo, Marja; Wahlstrom, Mikael

    2014-01-01

    Operations of safety critical industries unquestionably require a diversity of technical and organizational control measures to increase stability and predictability of the complex sociotechnical systems. Nevertheless, experiences from recent severe accidents and results of safety research have questioned the effectiveness of the prevailing safety management strategy that mainly relies on standardization and designed-in defenses. This paper discusses the identified need to balance between stability and flexibility in a concrete safety issue, i.e., proceduralization. The main research problem of our study is whether procedure guided practice can offer sufficient support for flexibility of operating activity. We shall frame our study with the help of a model that explains different aspects of procedures. We then elaborate how these different aspects were considered empirically in our 3-phase study. In the first study we interviewed 62 main control room operators and asked how they consider procedures to support balancing. In the second study we observed in detail 12 NPP operator crews' activity in a simulated loss-of-coolant accident. In a third study we inquired 5 procedure designers about their conceptions concerning procedure guidance in operator work. Drawing on either interview or behavioral data we analyzed the personnel's stance to the flexibility and stability balancing, and how the conceptions portray in the practices of procedure usage. Our results demonstrate that the operators are aware of the need for balancing flexibility and stability and consider successful balancing to represent 'good' professional action. In actual action many operators, however, tend towards more straightforward following of procedures. Designers also see the capability for balancing stability and flexibility as a key operator competence but describe actual acting simply as procedure-following. According to the documents of the nuclear community, procedure

  4. Can proceduralization support coping with the unexpected?

    Energy Technology Data Exchange (ETDEWEB)

    Norros, Leena; Savioja, Paula; Liinasuo, Marja; Wahlstrom, Mikael [VTT Technical Research Centre of Finland, Vuorimiehentie (Finland)

    2014-08-15

    Operations of safety critical industries unquestionably require a diversity of technical and organizational control measures to increase stability and predictability of the complex sociotechnical systems. Nevertheless, experiences from recent severe accidents and results of safety research have questioned the effectiveness of the prevailing safety management strategy that mainly relies on standardization and designed-in defenses. This paper discusses the identified need to balance between stability and flexibility in a concrete safety issue, i.e., proceduralization. The main research problem of our study is whether procedure guided practice can offer sufficient support for flexibility of operating activity. We shall frame our study with the help of a model that explains different aspects of procedures. We then elaborate how these different aspects were considered empirically in our 3-phase study. In the first study we interviewed 62 main control room operators and asked how they consider procedures to support balancing. In the second study we observed in detail 12 NPP operator crews' activity in a simulated loss-of-coolant accident. In a third study we inquired 5 procedure designers about their conceptions concerning procedure guidance in operator work. Drawing on either interview or behavioral data we analyzed the personnel's stance to the flexibility and stability balancing, and how the conceptions portray in the practices of procedure usage. Our results demonstrate that the operators are aware of the need for balancing flexibility and stability and consider successful balancing to represent 'good' professional action. In actual action many operators, however, tend towards more straightforward following of procedures. Designers also see the capability for balancing stability and flexibility as a key operator competence but describe actual acting simply as procedure-following. According to the documents of the nuclear community, procedure

  5. Robotic vascular resections during Whipple procedure

    OpenAIRE

    Allan, Bassan J.; Novak, Stephanie M.; Hogg, Melissa E.; Zeh, Herbert J.

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vas...

  6. Operating-procedure system at Savannah River Plant

    International Nuclear Information System (INIS)

    Tope, C.W.

    1981-05-01

    Three types of procedures are widely used at SRP: Du Pont Savannah Operating Logsheet, Du Pont Savannah Operating Procedure, and Plant Manual. This document briefly reviews originating of the procedures, their preparation, control, and indexing

  7. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  8. Surveillance of Environmental and Procedural Measures of Infection Control in the Operating Theatre Setting

    Directory of Open Access Journals (Sweden)

    Laura Dallolio

    2017-12-01

    Full Text Available The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs. The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0% were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.

  9. Laparoscopic reversal of Hartmann's procedure

    DEFF Research Database (Denmark)

    Svenningsen, Peter Olsen; Bulut, Orhan; Jess, Per

    2010-01-01

    of Hartmann's procedure as safely as in open surgery and with a faster recovery, shorter hospital stay and less blood loss despite a longer knife time. It therefore seems reasonable to offer patients a laparoscopic procedure at departments which are skilled in laparoscopic surgery and use it for standard...

  10. 32 CFR 145.6 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Procedures. 145.6 Section 145.6 National Defense... THE OFFICE OF SPECIAL COUNSEL OF THE MERIT SYSTEMS PROTECTION BOARD § 145.6 Procedures. (a... corrective or disciplinary action considered appropriate because of facts disclosed by such an investigation...

  11. 32 CFR 162.6 - Procedures.

    Science.gov (United States)

    2010-07-01

    ... Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DEFENSE CONTRACTING PRODUCTIVITY ENHANCING CAPITAL INVESTMENT (PECI) § 162.6 Procedures. The following procedures shall be followed by the DoD Components in the... documentation, pre-investment analysis, financing, and post-investment accountability of PECI projects, when DoD...

  12. XML Syntax for Clinical Laboratory Procedure Manuals

    OpenAIRE

    Saadawi, Gilan; Harrison, James H.

    2003-01-01

    We have developed a document type description (DTD) in Extensable Markup Language (XML)1 for clinical laboratory procedures. Our XML syntax can adequately structure a variety of procedure types across different laboratories and is compatible with current procedure standards. The combination of this format with an XML content management system and appropriate style sheets will allow efficient procedure maintenance, distributed access, customized display and effective searching across a large b...

  13. Payment Procedures for Electronic Government Services

    OpenAIRE

    Pousttchi, Key; Wiedemann, Dietmar Georg

    2005-01-01

    In this paper, we analyse payment procedures for their suitability for electronic government. We provide an overview of the payment procedures currently available on the market, compare the situation in electronic government with the situation in electronic commerce and analyze what we can transfer. Based on functional requirements we propose a scheme that allows public agencies to examine the appropriateness of any given payment procedure for electronic government.

  14. Nuclear Waste Fund cash management procedures

    International Nuclear Information System (INIS)

    1988-04-01

    The Nuclear Waste Policy Act if 1982 (NWPA) provided for the Office of Radioactive Waste Management (OCRWM) to adopt financial and accounting methods comparable to those used by private industry, including borrowing and investing authority. This document describes the procedures OCRWM follows to meet its borrowing and investing authority under the NWPA. These procedures are a supplement to, and are, therefore, not intended to supersede, existing Departmental policies and procedures

  15. Robotic vascular resections during Whipple procedure.

    Science.gov (United States)

    Allan, Bassan J; Novak, Stephanie M; Hogg, Melissa E; Zeh, Herbert J

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vascular resections. This report outlines our technique.

  16. Specified assurance level sampling procedure

    International Nuclear Information System (INIS)

    Willner, O.

    1980-11-01

    In the nuclear industry design specifications for certain quality characteristics require that the final product be inspected by a sampling plan which can demonstrate product conformance to stated assurance levels. The Specified Assurance Level (SAL) Sampling Procedure has been developed to permit the direct selection of attribute sampling plans which can meet commonly used assurance levels. The SAL procedure contains sampling plans which yield the minimum sample size at stated assurance levels. The SAL procedure also provides sampling plans with acceptance numbers ranging from 0 to 10, thus, making available to the user a wide choice of plans all designed to comply with a stated assurance level

  17. FFTF operations procedures preparation guide. Revision 2

    International Nuclear Information System (INIS)

    1976-12-01

    The Guide is intended to provide guidelines for the initial preparation of FFTF Operating Procedures. The Procedures Preparation Guide was developed from the plan presented and approved in the FFTF Reactor Plant Procedures Plan, PC-1, Revision 3

  18. Developing Competency in Payroll Procedures

    Science.gov (United States)

    Jackson, Allen L.

    1975-01-01

    The author describes a sequence of units that provides for competency in payroll procedures. The units could be the basis for a four to six week minicourse and are adaptable, so that the student, upon completion, will be able to apply his learning to any payroll procedures system. (Author/AJ)

  19. Proof Rules for Recursive Procedures

    NARCIS (Netherlands)

    Hesselink, Wim H.

    1993-01-01

    Four proof rules for recursive procedures in a Pascal-like language are presented. The main rule deals with total correctness and is based on results of Gries and Martin. The rule is easier to apply than Martin's. It is introduced as an extension of a specification format for Pascal-procedures, with

  20. Sphincter-saving procedure for radiation-injuried rectum

    International Nuclear Information System (INIS)

    Moriya, Yoshihiro; Koyama, Yasuo; Hojo, Keiichi

    1982-01-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter. (author)

  1. Radiation exposure during cardiac catheterization procedures

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Huyskens, C.J.; Michels, H.R.

    1988-01-01

    For some time there has been an increased interest in more information about radiation exposure during cardiac catheterization because of: relatively high doses to workers and patient; rapid increase of numbers of examinations; introduction of new procedure-types (e.g. Percutaneous Transluminal Coronary Angiography, PTCA) and introduction of new techniques (e.g. Digital Subtraction Angiography, DSA). This paper reports about a study on the exposure to medical personnel and patient in two major hospitals in the Netherlands. The Total number of cardiac catheterization procedures in both hospitals amounts to circa 3000 per year (approximately 10% of all cardiac procedures c.q. 20% of all PTCA procedures in the Netherlands). This study is related to 1300 cardiac examinations

  2. CT4 - Cost-Optimum Procedures

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Wittchen, Kim Bjarne

    This report collects the status in European member states regarding implementation of the cos optimum procedure for setting energy performance requirements to new and existing buildings.......This report collects the status in European member states regarding implementation of the cos optimum procedure for setting energy performance requirements to new and existing buildings....

  3. Unexpected effects of computer presented procedures

    International Nuclear Information System (INIS)

    Blackman, H.S.; Nelson, W.R.

    1988-01-01

    Results from experiments conducted at the Idaho National Engineering Laboratory have been presented regarding the computer presentation of procedural information. The results come from the experimental evaluation of an expert system which presented procedural instructions to be performed by a nuclear power plant operator. Lessons learned and implications from the study are discussed as well as design issues that should be considered to avoid some of the pitfalls in computer presented or selected procedures

  4. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  5. TMACS Test Procedure TP007: System administration

    International Nuclear Information System (INIS)

    Scanlan, P.; Washburn, S.; Seghers, R.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS System Administration functions

  6. Sphincter-saving procedure for radiation-injuried rectum. A report of four cases with special reference to pull-through procedure

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Y.; Koyama, Y.; Hojo, K. (National Cancer Center, Tokyo (Japan))

    1982-09-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter.

  7. PROCEDURAL CONVENTION AND FLEXIBILITY OF THE PROCED URE: THE INFLUENCE OF PRIVATE AUTONOMY ON THE PUBLICIST PARADIGM OF CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Marcelo Dias Ponte

    2015-12-01

    Full Text Available The research aims to analyze the New CPC innovations with regard to the procedural legal business, to assess, carefully, it s possibilities, its limits, requirements and the function of the court and the parties to the flexibility of the procedure. The study approaches the shared management of the procedure, the procedural calendar as materializing institute the principle of efficiency. As a result, it was found that procedural conventions have the power to better protect the substantive rights involved in the dispute, since the litigants may bring the procedural rite to the needs of the conflict, allowing a view democratic demand, able to increase dialogue and interaction between the parties.

  8. Modified Arthroscopic Brostrom Procedure With Bone Tunnels.

    Science.gov (United States)

    Lui, Tun Hing

    2016-08-01

    The open anatomic repair of the anterior talofibular and calcaneofibular ligaments (modified Brostrom procedure) is widely accepted as the standard surgical stabilization procedure for lateral ankle instability that does not respond to conservative measures. Arthroscopic Brostrom procedures with a suture anchor have been reported to achieve both anatomic repair of the lateral ankle ligaments and management of the associated intra-articular lesions. However, the complication rates are higher than open Brostom procedures. Many of these complications are associated with the use of a suture anchor. We report a modified arthroscopic Brostrom procedure in which the anterolateral ankle capsule is anchored to the lateral malleolus through small bone tunnels instead of suture anchors.

  9. Procedural violation in the licensing procedure and possible legal consequences; Verfahrensmaengel im Konzessionierungsverfahren und etwaige Rechtsfolgen

    Energy Technology Data Exchange (ETDEWEB)

    Meyer-Hetling, Astrid; Probst, Matthias Ernst; Wolkenhauer, Soeren [Kanzlei Becker Buettner Held (BBH), Berlin (Germany)

    2012-07-15

    With respect to paragraph 46 sect. 2 to 4 EnWG (Energy Economy Law) communities are required to provide a publication procedure and competition procedure ('licensing procedure') for the new assignment of easement agreements for the establishment of local power supply systems and natural gas supply systems. The specific design of the selection process legally is regulated only rudimentary. Nevertheless old concessionaires increasingly deny the statutory grid transfer to the new concessionaires relying on supposed errors in the selection process. The unclear legal situation and the inconsistent, sometimes unreasonably strict jurisdiction and jurisprudence of antitrust as well as regulatory authorities resulted to a considerable legal certainty in communities and grid operators. Unless the legislature establishes the necessary legal clarity, the competent courts and authorities are invoked to act moderately in the examination of licensing procedures.

  10. Procedural learning during declarative control.

    Science.gov (United States)

    Crossley, Matthew J; Ashby, F Gregory

    2015-09-01

    There is now abundant evidence that human learning and memory are governed by multiple systems. As a result, research is now turning to the next question of how these putative systems interact. For instance, how is overall control of behavior coordinated, and does learning occur independently within systems regardless of what system is in control? Behavioral, neuroimaging, and neuroscience data are somewhat mixed with respect to these questions. Human neuroimaging and animal lesion studies suggest independent learning and are mostly agnostic with respect to control. Human behavioral studies suggest active inhibition of behavioral output but have little to say regarding learning. The results of two perceptual category-learning experiments are described that strongly suggest that procedural learning does occur while the explicit system is in control of behavior and that this learning might be just as good as if the procedural system was controlling the response. These results are consistent with the idea that declarative memory systems inhibit the ability of the procedural system to access motor output systems but do not prevent procedural learning. (c) 2015 APA, all rights reserved).

  11. TMACS Test Procedure TP009: Acromag Driver

    International Nuclear Information System (INIS)

    Washburn, S.J.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS Acromag Software Driver (Bridge Code)

  12. 41 CFR 109-27.5007-1 - Procedures.

    Science.gov (United States)

    2010-07-01

    ...-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5007-1 Procedures. The following procedures shall be established for taking physical inventory of stocks subjected to quantity controls as well as those under financial control: (a) Completion of a physical inventory...

  13. 14 CFR 302.715 - Post-conference procedure.

    Science.gov (United States)

    2010-01-01

    ... desirable in the interest of further clarification and understanding of the issues. The granting of an... PROCEEDINGS) PROCEDURAL REGULATIONS RULES OF PRACTICE IN PROCEEDINGS Rules Applicable to Mail Rate Proceedings and Mail Contracts Informal Mail Rate Conference Procedure § 302.715 Post-conference procedure. No...

  14. The meaning of the administrative procedure

    Directory of Open Access Journals (Sweden)

    Martín Loo Gutiérrez

    2017-06-01

    Full Text Available The article seeks to present a substantive notion of the ‘administrative procedure’, that is, an understanding that departs from the merely procedural or formal meaning that has been consolidated in Chile from the definition adopted by the Administrative Procedures Act (“lbpa” and analyses the institutional purposes that have been assigned to the administrative procedure by foreign literature. The paper develops an explanation about the origins of this formal understanding and exposes the doctrine that has been consolidated in Europe to explain the institution from a substantial point of view. It is argued that this substantive notion can also be constructed in Chile from a systematic reading of some of the provisions of the law on administrative procedures.

  15. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  16. Procedures for ground-water investigations

    International Nuclear Information System (INIS)

    1989-09-01

    This manual was developed by the Pacific Northwest Laboratory (PNL) to document the procedures used to carry out and control the technical aspects of ground-water investigations at the PNL. Ground-water investigations are carried out to fulfill the requirements for the US Department of Energy (DOE) to meet the requirements of DOE Orders. Investigations are also performed for various clients to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA) and the Comprehensive Environmental Response, Compensation and Liability Act of 1980 (CERCLA). National standards including procedures published by the American Society for Testing and Materials (ASTM) and the US Geological Survey were utilized in developing the procedures contained in this manual

  17. Real-time whole-genome sequencing for routine typing, surveillance, and outbreak detection of verotoxigenic Escherichia coli.

    OpenAIRE

    Joensen, Katrine Grimstrup; Scheutz, Flemming; Lund, Ole; Hasman, Henrik; Kaas, Rolf Sommer; Nielsen, Eva M.; Aarestrup, Frank Møller

    2014-01-01

    Fast and accurate identification and typing of pathogens are essential for effective surveillance and outbreak detection. The current routine procedure is based on a variety of techniques, making the procedure laborious, time-consuming, and expensive. With whole-genome sequencing (WGS) becoming cheaper, it has huge potential in both diagnostics and routine surveillance. The aim of this study was to perform a real-time evaluation of WGS for routine typing and surveillance of verocytotoxin-prod...

  18. Real-Time Whole-Genome Sequencing for Routine Typing, Surveillance, and Outbreak Detection of Verotoxigenic Escherichia coli

    OpenAIRE

    Joensen, Katrine Grimstrup; Scheutz, Flemming; Lund, Ole; Hasman, Henrik; Kaas, Rolf S.; Nielsen, Eva M.; Aarestrup, Frank M.

    2014-01-01

    Fast and accurate identification and typing of pathogens are essential for effective surveillance and outbreak detection. The current routine procedure is based on a variety of techniques, making the procedure laborious, time-consuming, and expensive. With whole-genome sequencing (WGS) becoming cheaper, it has huge potential in both diagnostics and routine surveillance. The aim of this study was to perform a real-time evaluation of WGS for routine typing and surveillance of verocytotoxin-prod...

  19. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  20. Procedural Personas for Player Decision Modeling and Procedural Content Generation

    DEFF Research Database (Denmark)

    Holmgård, Christoffer

    2016-01-01

    ." These methods for constructing procedural personas are then integrated with existing procedural content generation systems, acting as critics that shape the output of these systems, optimizing generated content for different personas and by extension, different kinds of players and their decision making styles......How can player models and artificially intelligent (AI) agents be useful in early-stage iterative game and simulation design? One answer may be as ways of generating synthetic play-test data, before a game or level has ever seen a player, or when the sampled amount of play test data is very low....... This thesis explores methods for creating low-complexity, easily interpretable, generative AI agents for use in game and simulation design. Based on insights from decision theory and behavioral economics, the thesis investigates how player decision making styles may be defined, operationalised, and measured...

  1. Unexpected effects of computer presented procedures

    International Nuclear Information System (INIS)

    Blackman, H.S.; Nelson, W.R.

    1988-01-01

    Results from experiments conducted at the Idaho National Engineering Laboratory will be presented regarding the computer presentation of procedural information. The results come from the experimental evaluation of an expert system which presented procedural instructions to be performed by a nuclear power plant operator. Lessons learned and implications from the study will be discussed as well as design issues that should be considered to avoid some of the pitfalls in computer presented or selected procedures. 1 ref., 1 fig

  2. 28 CFR 40.3 - Communication of procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Communication of procedures. 40.3 Section... Standards for Inmate Grievance Procedures § 40.3 Communication of procedures. The written grievance... inmate and employee shall, upon arrival at the institution, receive written notification and an oral...

  3. 47 CFR 1.88 - Predesignation pleading procedure.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Predesignation pleading procedure. 1.88 Section... Rules of Practice and Procedure Miscellaneous Proceedings § 1.88 Predesignation pleading procedure. In... staff, in its discretion, may in writing, advise such licensee of the general nature of the...

  4. 12 CFR 7.2000 - Corporate governance procedures.

    Science.gov (United States)

    2010-01-01

    ... OPERATIONS Corporate Practices § 7.2000 Corporate governance procedures. (a) General. A national bank proposing to engage in a corporate governance procedure shall comply with applicable Federal banking... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Corporate governance procedures. 7.2000 Section...

  5. Performance audit procedures for opacity monitors

    International Nuclear Information System (INIS)

    Plaisance, S.J.; Peeler, J.W.

    1987-04-01

    This manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field-data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures are included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero-alignment or clear-path zero response are described. The zero-alignment procedures are included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero-alignment checks cannot usually be conducted during a performance audit

  6. A combined hands-on teaching programme and clinical pathway focused on pleural ultrasound and procedure supervision transforms pleural procedure outcomes.

    Science.gov (United States)

    Edwards, Timothy; Cook, Alistair; Salamonsen, Matthew; Bashirzadeh, Farzad; Fielding, David

    2017-11-01

    Management of pleural effusions is a common diagnostic and management problem. We reviewed the outcomes from pleural procedures after the instigation of pleural effusion management guidelines, focusing on pleural ultrasound and a hands-on teaching programme followed by procedure supervision that enabled many operators to perform such procedures. This is a retrospective analysis of all procedures performed for pleural effusions on medical patients. Outcomes were assessed prior to the instigation of pleural effusion management guidelines (pleural pathway) and hands-on teaching (January 2010 to June 2011) and following these interventions (January 2012 to June 2013). A total of 171 procedures involving 129 patients (pre-pathway group) and 146 procedures involving 115 patients (post-pathway group) was analysed. The rate of complications prior to the pleural pathway was 22.2% (38 of 171 procedures). Following the pathway, the rate of complications declined to 7.5% (11 of 146 procedures, P < 0.003). The use of pleural ultrasound increased dramatically (72.5 vs 90.2%). The number of patients who underwent repeated procedures (defined as ≥3) reduced dramatically (21 vs 7, P < 0.01). This improvement occurred using many supervised operators who completed the hands-on teaching programme (n = 32) and followed the pleural pathway (127 of 146 procedures). The instigation of a clinical pathway focused on the use of bedside pleural ultrasound, and teaching of drainage techniques with procedure supervision vastly improved patient outcomes. This not only allowed better quality of care for patients, it also provided the acquisition of new skills to medical staff, not limiting these skills to specialised staff. © 2017 Royal Australasian College of Physicians.

  7. Operational procedures - industry observations and opportunities for improvement

    International Nuclear Information System (INIS)

    Davey, E.

    2003-01-01

    The purpose of this paper is to relate some of the commonly encountered problems with operational procedures in the nuclear industry and offer practical suggestions for their elimination. The paper is based on recent consultant experience in assisting industry clients with human performance related design and assessment initiatives. Operational procedures are a key part of an integrated system design. Procedures provide the specified instructions for actions people are to undertake in operating a facility to achieve production and safety goals. While organizations continue to make substantial investments in procedure development and maintenance, problems with procedures continue to occur, as evidenced through operating inefficiencies, errors, and events. The paper reviews the role procedures play in facility operations, comments on current development and maintenance practices, discusses the extent of human performance related problems attributed to procedure deficiencies, reviews commonly encountered problems with design and implementation of procedures, and offers suggestions on how some of these issues might be addressed in the future. (author)

  8. A 1.5 hour procedure for identification of Enterococcus Species directly from blood cultures.

    Science.gov (United States)

    Morgan, Margie A; Marlowe, Elizabeth; Novak-Weekly, Susan; Miller, J M; Painter, T M; Salimnia, Hossein; Crystal, Benjamin

    2011-02-10

    Enterococci are a common cause of bacteremia with E. faecalis being the predominant species followed by E. faecium. Because resistance to ampicillin and vancomycin in E. faecalis is still uncommon compared to resistance in E. faecium, the development of rapid tests allowing differentiation between enterococcal species is important for appropriate therapy and resistance surveillance. The E. faecalis OE PNA FISH assay (AdvanDx, Woburn, MA) uses species-specific peptide nucleic acid (PNA) probes in a fluorescence in situ hybridization format and offers a time to results of 1.5 hours and the potential of providing important information for species-specific treatment. Multicenter studies were performed to assess the performance of the 1.5 hour E. faecalis/OE PNA FISH procedure compared to the original 2.5 hour assay procedure and to standard bacteriology methods for the identification of enterococci directly from a positive blood culture bottle.

  9. Diagnostic imaging procedure volume in the United States

    International Nuclear Information System (INIS)

    Johnson, J.L.; Abernathy, D.L.

    1983-01-01

    Comprehensive data on 1979 and 1980 diagnostic imaging procedure volume were collected from a stratified random sample of U.S. short-term general-care hospitals and private practices of radiologists, cardiologists, obstetricians/gynecologists, orthopedic surgeons, and neurologists/neurosurgeons. Approximately 181 million imaging procedures (within the study scope) were performed in 1980. Despite the rapidly increasing use of newer imaging methods, plain film radiography (140.3 million procedures) and contrast studies (22.9 million procedures) continue to comprise the vast majority of diagnostic imaging volume. Ultrasound, computed tomography, nuclear medicine, and special procedures make up less than 10% of total diagnostic imaging procedures. Comparison of the data from this study with data from an earlier study indicates that imaging procedure volume in hospitals expanded at an annual growth rate of almost 8% from 1973 to 1980

  10. 75 FR 68022 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2010-11-04

    ...The FAA is issuing this notice to advise the public that a new charter has been issued for the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC). The duties of this advisory committee include: 1. To make recommendations for standardizing, clarifying, and upgrading terminology and procedures, as a result of its review of present ATC procedures and practices. 2. To provide advice and make recommendations concerning: a. New or significantly revised ATC procedural concepts. b. The adequacy of charts, diagrams, and illustrations used to convey information concerning the application of ATC procedures and their relevance to current, revised, or proposed ATC procedures and concepts. c. Aviation regulations that have an impact on present, new, or significantly revised ATC procedures and concepts. 3. To act solely in an advisory capacity to accomplish its duties.

  11. 25 CFR 141.59 - Customer complaint procedures.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Customer complaint procedures. 141.59 Section 141.59... THE NAVAJO, HOPI AND ZUNI RESERVATIONS Enforcement Powers, Procedures and Remedies § 141.59 Customer complaint procedures. (a) Any customer of a licensee may file a complaint with the Commissioner alleging...

  12. Occupational exposures from selected interventional radiological procedures

    International Nuclear Information System (INIS)

    Janeczek, J.; Beal, A.; James, D.

    2001-01-01

    The number of radiology and cardiology interventional procedures has significantly increased in recent years due to better diagnostic equipment resulting in an increase in radiation dose to the staff and patients. The assessment of staff doses was performed for cardiac catheterization and for three other non-cardiac procedures. The scattered radiation distribution resulting from the cardiac catheterization procedure was measured prior to the staff dose measurements. Staff dose measurements included those of the left shoulder, eye, thyroid and hand doses of the cardiologist. In non-cardiac procedures doses to the hands of the radiologist were measured for nephrostomy, fistulogram and percutaneous transluminal angioplasty procedures. Doses to the radiologist or cardiologist were found to be relatively high if correct protection was not observed. (author)

  13. Face-off: A new identification procedure for child eyewitnesses.

    Science.gov (United States)

    Price, Heather L; Fitzgerald, Ryan J

    2016-09-01

    In 2 experiments, we introduce a new "face-off" procedure for child eyewitness identifications. The new procedure, which is premised on reducing the stimulus set size, was compared with the showup and simultaneous procedures in Experiment 1 and with modified versions of the simultaneous and elimination procedures in Experiment 2. Several benefits of the face-off procedure were observed: it was significantly more diagnostic than the showup procedure; it led to significantly more correct rejections of target-absent lineups than the simultaneous procedures in both experiments, and it led to greater information gain than the modified elimination and simultaneous procedures. The face-off procedure led to consistently more conservative responding than the simultaneous procedures in both experiments. Given the commonly cited concern that children are too lenient in their decision criteria for identification tasks, the face-off procedure may offer a concrete technique to reduce children's high choosing rates. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. Motive Criminal Procedure Evidence

    Directory of Open Access Journals (Sweden)

    В. В. Вапнярчук

    2015-03-01

    Full Text Available In the article the need for such a level of mental regulation of behavior of proving motivation. The latter refers to internal motivation conscious entity Criminal Procedure proof, due to specific needs, interests and goals that cause a person to act rishymist. Detailed attention is given to the first two determinants, namely the nature of needs and interests. In particular, analyzes highlighted in the literature variety of needs (physiological, ekzistentsionalni, social, prestige, cognitive, aesthetic and spiritual and the manifestation of some of them in the criminal procedural proof.

  15. Civil rights reference of administrative procedures

    International Nuclear Information System (INIS)

    Held, J.

    1984-01-01

    The book deals with the constitutional obligations which substantive civil rights demand from administrative procedures. The Federal Constitutional Court distinguishes between protection of civil rights in, and by, administrative and judicial procedures. The author analyses the example of the decision of the Federal Constitutional Court concerning the atomic power plant of Muelheim-Kaerlich. In the licensing procedure pursuant to the Atomic Energy Act, the civil rights of persons concerned are guaranteed by the governmental obligation to its protection. (CW) [de

  16. State Token Petri Net modeling method for formal verification of computerized procedure including operator's interruptions of procedure execution flow

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Seong, Poong Hyun

    2012-01-01

    The Computerized Procedure System (CPS) is one of the primary operating support systems in the digital Main Control Room. The CPS displays procedure on the computer screen in the form of a flow chart, and displays plant operating information along with procedure instructions. It also supports operator decision making by providing a system decision. A procedure flow should be correct and reliable, as an error would lead to operator misjudgement and inadequate control. In this paper we present a modeling for the CPS that enables formal verification based on Petri nets. The proposed State Token Petri Nets (STPN) also support modeling of a procedure flow that has various interruptions by the operator, according to the plant condition. STPN modeling is compared with Coloured Petri net when they are applied to Emergency Operating Computerized Procedure. A converting program for Computerized Procedure (CP) to STPN has been also developed. The formal verification and validation methods of CP with STPN increase the safety of a nuclear power plant and provide digital quality assurance means that are needed when the role and function of the CPS is increasing.

  17. The importance of procedural defects in Atomic Law

    International Nuclear Information System (INIS)

    Ossenbuehl, F.

    1981-01-01

    The Muelheim-Kaerlich decision of the Federal Constitutional Court has brought about a 'revaluation' of procedural requirements. This has caused some insecurity in the application of procedural requirements, e.g. whether a license under Nuclear Law, granted without public participation in spite of procedural requirements, can be revolved on the basis of this procedural defect alone. The answer depends on the applicability of Sect. 46 VwVfG (Act on Procedural Rules) in Nuclear Law. (orig.) [de

  18. The status of penile enhancement procedures.

    Science.gov (United States)

    Vardi, Yoram; Gruenwald, Ilan

    2009-11-01

    Most men who request surgical penile enhancement have a normal-sized and fully functional penis but visualize their penises as small (psychological dysmorphism). This fact by itself leads to controversy regarding the true indications for penile enhancement procedures in men without micropenis. One of the typical aspects of penile enhancement is the lack of true methodological evaluation of the more commonly performed procedures. Even recently, only few solid scientific studies are available which can shed some light on results and outcome of these controversial procedures. Although some additional data has emerged during the past year, there is still no consensus in regard to indications and surgical techniques used for penile augmentation or penile girth enhancement. There is further need for more studies to provide a better overview of the value and worthiness of these procedures.

  19. Gadolinium Use in Spine Pain Management Procedures for Patients with Contrast Allergies: Results in 527 Procedures

    International Nuclear Information System (INIS)

    Safriel, Yair; Ang, Roberto; Ali, Muhammed

    2008-01-01

    Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualized using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered

  20. 28 CFR 34.102 - Peer review procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Peer review procedures. 34.102 Section 34.102 Judicial Administration DEPARTMENT OF JUSTICE OJJDP COMPETITION AND PEER REVIEW PROCEDURES Peer Review § 34.102 Peer review procedures. The OJJDP peer review process is contained in an OJJDP “Peer...

  1. 40 CFR 89.406 - Pre-test procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Pre-test procedures. 89.406 Section 89.406 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED... Procedures § 89.406 Pre-test procedures. (a) Allow a minimum of 30 minutes warmup in the standby or operating...

  2. 32 CFR 14.3 - Policies and procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Policies and procedures. 14.3 Section 14.3... QUALIFICATION OF CIVILIAN DEFENSE COUNSEL § 14.3 Policies and procedures. (a) Application procedures. (1... the subject of any sanction or disciplinary action by any court, bar, or other competent governmental...

  3. Realism of procedural task trainers in a pediatric emergency medicine procedures course.

    Science.gov (United States)

    Shefrin, Allan; Khazei, Afshin; Cheng, Adam

    2015-01-01

    Pediatric emergency medicine (PEM) physicians have minimal experience in life saving procedures and have turned to task trainers to learn these skills. Realism of these models is an important consideration that has received little study. PEM physicians and trainees participated in a day long procedural training course that utilized commercially available and homemade task trainers to teach pericardiocentesis, chest tube insertion, cricothyroidotomy and central line insertion. Participants rated the realism of the task trainers as part of a post-course survey. The homemade task trainers received variable realism ratings, with 91% of participants rating the pork rib chest tube model as realistic, 82% rating the gelatin pericardiocentesis mold as realistic and 36% rating the ventilator tubing cricothyroidotomy model as realistic. Commercial trainers also received variable ratings, with 45% rating the chest drain and pericardiocentesis simulator as realistic, 74% rating the crichotracheotomy trainer as realistic and 80% rating the central line insertion trainer as realistic. Task training models utilized in our course received variable realism ratings. When deciding what type of task trainer to use future courses should carefully consider the desired aspect of realism, and how it aligns with the procedural skill, balanced with cost considerations.

  4. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  5. MR diagnostics after Ross procedure

    International Nuclear Information System (INIS)

    Steffens, J.C.; Link, J.; Harringer, W.; Haverich, A.; Heller, M.

    1996-01-01

    Purpose: To determine the ability of MRI to diagnose morphological and functional changes in patients after Ross procedure. Material and methods: During one year, 5 patients after Ross procedure were studied by MRI. T 1 -weighted spin-echo sequences in different orientations as well as cine sequences and a VENC-sequence were used. Results: In all patients the morphology including the postoperative changes could be visualised by MRI. The cine sequences provided functional information on valvular and ventricular function. VENC-MR yielded an exact quantification of the regurgitant fraction. Conclusion: MRI is capable of providing all important diagnostic information in patients after Ross procedure such as valvular and ventricular function and valvular and outflow tract morphology in a single examination. (orig.) [de

  6. Management of the Bohunice RPVs annealing procedures

    International Nuclear Information System (INIS)

    Repka, M.

    1994-01-01

    The program of annealing regeneration procedure of RPVs units 1 and 2 of NPP V-1 (EBO) realization in the year 1993, is the topic of this paper. In the paper the following steps are described in detail: the preparation works, the annealing procedure realization schedule and safety management: starting with zero conditions, assembling of annealing apparatus, annealing procedure, cooling down and disassembling procedure of annealing apparatus. At the end the programs of annealing of both RPVs including the dosimetry measurements are discussed and evaluated. (author). 3 figs

  7. Cosmetic Procedure Questions

    Science.gov (United States)

    ... Back Injectable Deoxycholic Acid Injectable Hyaluronic Acid Injectable Poly-l-lactic Acid Injectable Polymethylmethacrylate + Bovine Collagen Filler ... time of their procedure. 6. What are my pain management and anesthesia options? To help avoid the ...

  8. 24 CFR 291.210 - Direct sales procedures.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Direct sales procedures. 291.210... URBAN DEVELOPMENT HUD-OWNED PROPERTIES DISPOSITION OF HUD-ACQUIRED SINGLE FAMILY PROPERTY Sales Procedures § 291.210 Direct sales procedures. When HUD conducts the sales listed in § 291.90(c), it will sell...

  9. Procedures for the selection of stopping power ratios for electron beams: Comparison of IAEA TRS procedures and of DIN procedures with Monte Carlo results

    International Nuclear Information System (INIS)

    Roos, M.; Christ, G.

    2000-01-01

    In the International Code of Practice IAEA TRS-381 the stopping power ratios water/air are selected according to the half-value depth and the depth of measurement. In the German Standard DIN 6800-2 a different procedure is recommended, which, in addition, takes the practical electron range into account; the stopping power data for monoenergetic beams from IAEA TRS-381 are used. Both procedures are compared with recent Monte Carlo calculations carried out for various beams of clinical accelerators. It is found that the DIN procedure shows a slightly better agreement. In addition, the stopping power ratios in IAEA TRS-381 are compared with those in DIN 6800-2 for the reference conditions of the beams from the PTB linac; the maximum deviation is not larger than 0.6%. (author)

  10. Transthoracic Adrenal Biopsy Procedure Using Artificial Carbon Dioxide Pneumothorax as Outpatient Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Favelier, Sylvain [CHU (University Hospital), Department of Radiology (France); Guiu, Severine [Georges-Francois Leclerc Cancer Center, Department of Oncology (France); Cherblanc, Violaine; Cercueil, Jean-Pierre; Krause, Denis; Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr [CHU (University Hospital), Department of Radiology (France)

    2013-08-01

    Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO{sub 2}) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO{sub 2} was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

  11. Reliability of application of inspection procedures

    Energy Technology Data Exchange (ETDEWEB)

    Murgatroyd, R A

    1988-12-31

    This document deals with the reliability of application of inspection procedures. A method to ensure that the inspection of defects thanks to fracture mechanics is reliable is described. The Systematic Human Error Reduction and Prediction Analysis (SHERPA) methodology is applied to every task performed by the inspector to estimate the possibility of error. It appears that it is essential that inspection procedures should be sufficiently rigorous to avoid substantial errors, and that the selection procedures and the training period for inspectors should be optimised. (TEC). 3 refs.

  12. Reliability of application of inspection procedures

    International Nuclear Information System (INIS)

    Murgatroyd, R.A.

    1988-01-01

    This document deals with the reliability of application of inspection procedures. A method to ensure that the inspection of defects thanks to fracture mechanics is reliable is described. The Systematic Human Error Reduction and Prediction Analysis (SHERPA) methodology is applied to every task performed by the inspector to estimate the possibility of error. It appears that it is essential that inspection procedures should be sufficiently rigorous to avoid substantial errors, and that the selection procedures and the training period for inspectors should be optimised. (TEC)

  13. Bariatric Surgery Procedures

    Science.gov (United States)

    ... Meetings of Interest Online Education Job Board CME Policies CBN Fellowship Certificate Research Grant Program Resources All Resources Approved Procedures Patient Safety Vignettes Dr. Mason Historical Library Governing Documents Guidelines Access and Insurance Position and ...

  14. COLLABORATIVE PROCEDURE TO ACHIEVE AN EFFECTIVE JURISDICTIONAL TUTELAGE

    Directory of Open Access Journals (Sweden)

    Darilê Marques da Matta

    2015-12-01

    Full Text Available Set in a constitutional context, the procedure should be an effective instrument for the guarantee and realization of rights. Attentive to the needs imposed by the state of Law, the new Civil Procedure Code, approved this year, 2 015, seeks to settle several constitutional guarantees, for the purpose of making the procedure more effective. From the inclusion of collaborative institutes, the new Civil Procedure C ode introduces the concept of self-composition and cooperation of procedural agents to achieve, timely, effective jurisdictional tutelage.

  15. 25 CFR 11.503 - Applicable civil procedure.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Applicable civil procedure. 11.503 Section 11.503 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER COURTS OF INDIAN OFFENSES AND LAW AND ORDER CODE Civil Actions § 11.503 Applicable civil procedure. The procedure to be followed in civil...

  16. 12 CFR 907.12 - Finance Board procedures.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Finance Board procedures. 907.12 Section 907.12 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOUSING FINANCE BOARD ORGANIZATION AND OPERATIONS PROCEDURES Case-by-Case Determinations; Review of Disputed Supervisory Determinations § 907.12 Finance Board procedures. (a) Notice of Receipt...

  17. Radiation safety in nuclear medicine procedures

    International Nuclear Information System (INIS)

    Cho, Sang Geon; Kim, Ja Hae; Song, Ho Chun

    2017-01-01

    Since the nuclear disaster at the Fukushima Daiichi Nuclear Power Plant in 2011, radiation safety has become an important issue in nuclear medicine. Many structured guidelines or recommendations of various academic societies or international campaigns demonstrate important issues of radiation safety in nuclear medicine procedures. There are ongoing efforts to fulfill the basic principles of radiation protection in daily nuclear medicine practice. This article reviews important principles of radiation protection in nuclear medicine procedures. Useful references, important issues, future perspectives of the optimization of nuclear medicine procedures, and diagnostic reference level are also discussed

  18. Health Code Number (HCN) Development Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Petrocchi, Rocky; Craig, Douglas K.; Bond, Jayne-Anne; Trott, Donna M.; Yu, Xiao-Ying

    2013-09-01

    This report provides the detailed description of health code numbers (HCNs) and the procedure of how each HCN is assigned. It contains many guidelines and rationales of HCNs. HCNs are used in the chemical mixture methodology (CMM), a method recommended by the department of energy (DOE) for assessing health effects as a result of exposures to airborne aerosols in an emergency. The procedure is a useful tool for proficient HCN code developers. Intense training and quality assurance with qualified HCN developers are required before an individual comprehends the procedure to develop HCNs for DOE.

  19. Radiation safety in nuclear medicine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang Geon; Kim, Ja Hae; Song, Ho Chun [Dept. of Nuclear Medicine, Medical Radiation Safety Research Center, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2017-03-15

    Since the nuclear disaster at the Fukushima Daiichi Nuclear Power Plant in 2011, radiation safety has become an important issue in nuclear medicine. Many structured guidelines or recommendations of various academic societies or international campaigns demonstrate important issues of radiation safety in nuclear medicine procedures. There are ongoing efforts to fulfill the basic principles of radiation protection in daily nuclear medicine practice. This article reviews important principles of radiation protection in nuclear medicine procedures. Useful references, important issues, future perspectives of the optimization of nuclear medicine procedures, and diagnostic reference level are also discussed.

  20. Towards a procedure for metaphor identification

    NARCIS (Netherlands)

    Steen, G.J.

    2002-01-01

    This article aims to demonstrate the possibility of a stepwise procedure for metaphor identification. It is situated against the background of a more encompassing and complete five-step procedure for deriving conceptual metaphorical mappings from linguistic metaphors. The mainly cognitive linguistic

  1. 40 CFR 68.52 - Operating procedures.

    Science.gov (United States)

    2010-07-01

    ...) CHEMICAL ACCIDENT PREVENTION PROVISIONS Program 2 Prevention Program § 68.52 Operating procedures. (a) The... for safely conducting activities associated with each covered process consistent with the safety information for that process. Operating procedures or instructions provided by equipment manufacturers or...

  2. 40 CFR 7.90 - Grievance procedures.

    Science.gov (United States)

    2010-07-01

    ...) Exception. Recipients with fewer than fifteen (15) full-time employees need not comply with this section... Recipients § 7.90 Grievance procedures. (a) Requirements. Each recipient shall adopt grievance procedures... significantly impair the recipient's ability to provide benefits or services. ...

  3. 5 CFR 179.304 - Notification procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Notification procedures. 179.304 Section 179.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.304 Notification procedures. Before collecting any debt...

  4. Applying computer-based procedures in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Mauro V. de; Carvalho, Paulo V.R. de; Santos, Isaac J.A.L. dos; Grecco, Claudio H.S. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Instrumentacao e Confiabilidade Humana], e-mail: mvitor@ien.gov.br, e-mail: paulov@ien.gov.br, e-mail: luquetti@ien.gov.br, e-mail: grecco@ien.gov.br; Bruno, Diego S. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola Politecnica. Curso de Engenharia de Controle e Automacao], e-mail: diegosalomonebruno@gmail.com

    2009-07-01

    Plant operation procedures are used to guide operators in coping with normal, abnormal or emergency situations in a process control system. Historically, the plant procedures have been paper-based (PBP), with the digitalisation trend in these complex systems computer-based procedures (CBPs) are being developed to support procedure use. This work shows briefly the research on CBPs at the Human-System Interface Laboratory (LABIHS). The emergency operation procedure EOP-0 of the LABIHS NPP simulator was implemented in the ImPRO CBP system. The ImPRO system was chosen for test because it is available for download in the Internet. A preliminary operation test using the implemented procedure in the CBP system was realized and the results were compared to the operation through PBP use. (author)

  5. Automated procedure execution for space vehicle autonomous control

    Science.gov (United States)

    Broten, Thomas A.; Brown, David A.

    1990-01-01

    Increased operational autonomy and reduced operating costs have become critical design objectives in next-generation NASA and DoD space programs. The objective is to develop a semi-automated system for intelligent spacecraft operations support. The Spacecraft Operations and Anomaly Resolution System (SOARS) is presented as a standardized, model-based architecture for performing High-Level Tasking, Status Monitoring and automated Procedure Execution Control for a variety of spacecraft. The particular focus is on the Procedure Execution Control module. A hierarchical procedure network is proposed as the fundamental means for specifying and representing arbitrary operational procedures. A separate procedure interpreter controls automatic execution of the procedure, taking into account the current status of the spacecraft as maintained in an object-oriented spacecraft model.

  6. SOME CONSIDERATIONS REGARDING THE AD-HOC INTERNAL ARBITRATION PROCEDURE IN THE NEW CODE OF CIVIL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Daniela Cristina Creţ

    2013-12-01

    Full Text Available One of the institutions to have undergone essential changes as a result of the 2013 entry into force of the New Code of civil procedure is arbitration. Arbitration is an alternative way of settling conflicts by means of a specialized person or institution, based on the will of the parties or on an international convention. This article will present a few introductory aspects that are essential for a foray into the field, as well as analyze the main aspects of arbitral procedure from the perspective of novelties and changes brought to the provisions of the New Code of civil procedure (hereinafter referred to as N.C.C.P..

  7. Cosmetic Procedure Questions

    Science.gov (United States)

    ... for Every Season How to Choose the Best Skin Care Products In This Section Dermatologic Surgery What is dermatologic ... for Every Season How to Choose the Best Skin Care Products Cosmetic Procedure Questions Want to look younger? Start ...

  8. MITS Feed and Withdrawal Subsystem: operating procedures

    International Nuclear Information System (INIS)

    Brown, W.S.

    1980-01-01

    This document details procedures for the operation of the MITS (Machine Interface Test System) Feed and Withdrawal Subsystem (F and W). Included are fill with UF 6 , establishment of recycle and thruput flows, shutdown, UF 6 makeup, dump to supply container, Cascade dump to F and W, and lights cold trap dump, all normal procedures, plus an alternate procedure for trapping light gases

  9. Procedures for mastitis diagnosis and control.

    Science.gov (United States)

    Sears, P M; González, R N; Wilson, D J; Han, H R

    1993-11-01

    Procedures for mastitis diagnosis and control include culturing individual cow and bulk tank milk samples, antibiotic susceptibility testing, and evaluation of somatic cell count reports and clinical mastitis treatment records. Integrated use of such procedures is necessary for effective mastitis diagnosis and control.

  10. 40 CFR 73.12 - Rounding Procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Rounding Procedures. 73.12 Section 73.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Allowance Allocations § 73.12 Rounding Procedures. (a) Calculation...

  11. 5 CFR 179.308 - Accelerated procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Accelerated procedures. 179.308 Section 179.308 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.308 Accelerated procedures. OPM may make an administrative...

  12. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.; Babikir, E.; Sulieman, A.; Daar, E.; Alnaaimi, M.; Alduaij, M.; Bradley, D.

    2016-10-01

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm 2 ) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  13. Neurosurgical procedures in Jehovah's Witnesses: the Tema experience.

    Science.gov (United States)

    Andrews, N B

    2009-05-01

    On account of religious reasons, Jehovah Witnesses do not accept blood or blood products; occasionally, they accept reinfusion of autologous blood via a cell saver during surgery. The aim of this study was to document the demographics of Jehovah Witnesses undergoing neurosurgical procedures, the neurosurgical procedures undertaken in Jehovah Witnesses and to evaluate the complications of the procedures. A retrospective audit of the medical records of all Jehovah's Witnesses who underwent neurosurgical procedures at our institution, from January 1st 2000 to December 31st 2006, was carried out. The parameters investigated included demographics, pre and post operative diagnosis, type of neurosurgical procedure and complications. Nineteen patients (fifteen male, four female; male/female 3.8:1) constituted the series. The mean age was 45.8 (range: 20-65) years. A total of 21 procedures were performed; intracranial surgery (33%), spinal surgery (67%). No autotransfusion of blood was given. Lumbar laminectomy for stenosis was the commonest spine procedure, ten (71.4%); craniotomy for tumor excision was the commonest intracranial procedure, six (85.7%). With respect to the whole series, the morbidity rate was 4.7% and the mortality rate was 4.7%; both were from intracranial surgery. It is possible to perform certain types of neurosurgical procedures in Jehovah's Witnesses without increasing the mortality and morbidity rate.

  14. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj 11942 (Saudi Arabia); Daar, E. [University of Jordan, Faculty of Science, Department of Physics, Amman 11942 (Jordan); Alnaaimi, M.; Alduaij, M. [Kuwait Cancer Control Centre, Department of Nuclear Medicine, Shwiekh (Kuwait); Bradley, D., E-mail: malkhorayef@ksu.edu.sa [University of Surrey, Centre for Nuclear and Radiation Physics, Guildford, Surrey, GU2 7XH (United Kingdom)

    2016-10-15

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm{sup 2}) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  15. Pain Management for Gynecologic Procedures in the Office.

    Science.gov (United States)

    Ireland, Luu Doan; Allen, Rebecca H

    2016-02-01

    Satisfactory pain control for women undergoing office gynecologic procedures is critical for both patient comfort and procedure success. Therefore, it is important for clinicians to be aware of the safety and efficacy of different pain control regimens. This article aimed to review the literature regarding pain control regimens for procedures such as endometrial biopsy, intrauterine device insertion, colposcopy and loop electrosurgical excisional procedure, uterine aspiration, and hysteroscopy. A search of published literature using PubMed was conducted using the following keywords: "pain" or "anesthesia." These terms were paired with the following keywords: "intrauterine device" or "IUD," "endometrial biopsy," "uterine aspiration" or "abortion," "colposcopy" or "loop electrosurgical excisional procedure" or "LEEP," "hysteroscopy" or "hysteroscopic sterilization." The search was conducted through July 2015. Articles were hand reviewed and selected by the authors for study quality. Meta-analyses and randomized controlled trials were prioritized. Although local anesthesia is commonly used for gynecologic procedures, a multimodal approach may be more effective including oral medication, a dedicated emotional support person, and visual or auditory distraction. Women who are nulliparous, are postmenopausal, have a history of dysmenorrhea, or suffer from anxiety are more likely to experience greater pain with gynecologic procedures. Evidence for some interventions exists; however, the interpretation of intervention comparisons is limited by the use of different regimens, pain measurement scales, patient populations, and procedure techniques. There are many options for pain management for office gynecologic procedures, and depending on the procedure, different modalities may work best. The importance of patient counseling and selection cannot be overstated.

  16. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  17. HASL procedures manual

    International Nuclear Information System (INIS)

    1980-08-01

    Addition and corrections to the following sections of the HASL Procedures Manual are provided: Table of Contents; Bibliography; Fallout Collection Methods; Wet/Dry Fallout Collection; Fluoride in Soil and Sediment; Strontium-90; Natural Series; Alpha Emitters; and Gamma Emitters

  18. Reactor Vessel Surveillance Program for Advanced Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyeong-Hoon; Kim, Tae-Wan; Lee, Gyu-Mahn; Kim, Jong-Wook; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-15

    This report provides the design requirements of an integral type reactor vessel surveillance program for an integral type reactor in accordance with the requirements of Korean MEST (Ministry of Education, Science and Technology Development) Notice 2008-18. This report covers the requirements for the design of surveillance capsule assemblies including their test specimens, test block materials, handling tools, and monitors of the surveillance capsule neutron fluence and temperature. In addition, this report provides design requirements for the program for irradiation surveillance of reactor vessel materials, a layout of specimens and monitors in the surveillance capsule, procedures of installation and retrieval of the surveillance capsule assemblies, and the layout of the surveillance capsule assemblies in the reactor.

  19. Procedures and practices for abnormal occurrences and emergencies

    International Nuclear Information System (INIS)

    Blaesig, H.

    1986-01-01

    This lecture contains the concept of the Emergency Operating Procedures (EOPs) of German power plants. As the procedures depend on the technique of the plant the level of automation and the types of information are described first. After this, the method to diagnose a transient or accident, following entry into an emergency procedure is explained. An overview about the design basis accidents and the aim of the actions in the procedures is given basing on the existing rules and regulations. Finally the theoretical principles are explained taking the corresponding procedures and examples of two German PWRs. (orig.)

  20. Patients' satisfaction with the Nuss procedure

    International Nuclear Information System (INIS)

    Ishimaru, Tetsuya; Iwanaka, Tadashi; Uchida, Hiroo; Kawashima, Hiroshi; Gotoh, Chikashi; Satoh, Kaori; Yoshida, Mariko; Kitano, Yoshihiro

    2009-01-01

    The purpose of this study is to investigate the satisfaction of patients who have already finished bar removal. Fifty-four patients with pectus excavatum underwent the Nuss procedure between July 2000 and December 2007 and the bar was removed in 41 of them at our hospital. A telephone questionnaire was administered to their parents or the patients (12 years old or older). The questions were as follows: self-assessment of the present thoracic form on a 5-point scale, whether it was good to have undergone the Nuss procedure (Y/N), whether the patient will recommend this procedure to another patient (Y/N). Thirty-nine patients responded to the questionnaire. Median age at the bar insertion was 83 months (range: 63-189 months). The bar was removed about 2 years after the initial operation. The median period after removal was 29 months ( range: 2-65 months). The mean point for the thoracic form was 4.2 (5 points: 20, 4 points: 11, 3 points: 5, 2 points: 3). Thirty-eight patients answered that they were satisfied with this procedure. Thirty-four patients answered that they would recommend this procedure to another patient. Eight patients reported that redepression occurred after bar removal. Six of them are under observation because their thoracic deformity is mild. Patients' satisfaction with the Nuss procedure was high. However, our study shows the possibility of post-removal recurrence. There seems to be a tendency for patients to assess their thoracic form more strictly than the doctors. (author)

  1. On the way towards a generalized entropy maximization procedure

    International Nuclear Information System (INIS)

    Bagci, G. Baris; Tirnakli, Ugur

    2009-01-01

    We propose a generalized entropy maximization procedure, which takes into account the generalized averaging procedures and information gain definitions underlying the generalized entropies. This novel generalized procedure is then applied to Renyi and Tsallis entropies. The generalized entropy maximization procedure for Renyi entropies results in the exponential stationary distribution asymptotically for q element of (0,1] in contrast to the stationary distribution of the inverse power law obtained through the ordinary entropy maximization procedure. Another result of the generalized entropy maximization procedure is that one can naturally obtain all the possible stationary distributions associated with the Tsallis entropies by employing either ordinary or q-generalized Fourier transforms in the averaging procedure.

  2. 46 CFR 296.40 - Billing procedures.

    Science.gov (United States)

    2010-10-01

    ... OPERATORS MARITIME SECURITY PROGRAM (MSP) Billing and Payment Procedures § 296.40 Billing procedures. Submission of voucher. For contractors operating under more than one MSP Operating Agreement, the contractor may submit a single monthly voucher applicable to all its MSP Operating Agreements. Each voucher...

  3. 29 CFR 1614.305 - Consideration procedures.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Consideration procedures. 1614.305 Section 1614.305 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION FEDERAL SECTOR EQUAL EMPLOYMENT OPPORTUNITY Related Processes § 1614.305 Consideration procedures. (a) Once a petition is filed...

  4. 25 CFR 225.21 - Negotiation procedures.

    Science.gov (United States)

    2010-04-01

    ... setting forth the duration of the minerals agreement; (3) A statement providing indemnification to the... accounting and mineral valuation procedures; (8) Provisions establishing operating and management procedures... refusal by the Indian mineral owner in the event of a proposed assignment; (10) Bond requirements; (11...

  5. Grid - a fast threshold tracking procedure

    DEFF Research Database (Denmark)

    Fereczkowski, Michal; Dau, Torsten; MacDonald, Ewen

    2016-01-01

    A new procedure, called “grid”, is evaluated that allows rapid acquisition of threshold curves for psychophysics and, in particular, psychoacoustic, experiments. In this method, the parameterresponse space is sampled in two dimensions within a single run. This allows the procedure to focus more e...

  6. Smoke as a pictorial procedure: Fumage

    Directory of Open Access Journals (Sweden)

    José Antonio Pérez Esteban

    2013-01-01

    Full Text Available I propose a new definition for fumage and address in a brief approach —from the chemical point of view— the nature of smoke. From this base, I study the possible supports, potential tools for application in artistic purposes, visual possibilities, attachment procedure and narrative connotations related to its use. Next, I analyze its connections with the related heat engraving art. To finish and justifying the new definition which claims the contemporaneity of the procedure, I bring a list of artists who have used and, mainly, who are using this procedure in their artistic proposals.

  7. Avoiding Psychological Pitfalls in Aesthetic Medical Procedures.

    Science.gov (United States)

    Wang, Qiuyu; Cao, Chuan; Guo, Rui; Li, Xiaoge; Lu, Lele; Wang, Wenping; Li, Shirong

    2016-12-01

    To assess the prevalence of body dysmorphic disorder (BDD) in an aesthetic surgery setting in the region of Southwest China, and to ascertain the differences in terms of body images between patients in the aesthetic setting and general Chinese population. This study tracked patient satisfaction with their body image changes while undergoing aesthetic medical procedures to identify whether the condition of patients who were presenting with BDD symptoms or their psychological symptoms could be improved by enhancing their appearance. Additionally, this study explored whether there was improvement in quality of life (QoL) and self-esteem after aesthetic medical procedures. A total of 106 female patients who were undergoing aesthetic medical procedures for the first time (plastic surgery, n = 26; minimally invasive aesthetic treatment, n = 42; and aesthetic dermatological treatment, n = 38) were classified as having body dysmorphic disorder symptoms or not having body dysmorphic disorder symptoms, based on the body dysmorphic disorder examination (BDDE), which was administered preoperatively. These patients were followed up for 1 month after the aesthetic procedures. The multidimensional body self-relations questionnaire-appearance scales (MBSRQ-AS) and rosenberg self-esteem scale (RSE-S) were used to assess patients' preoccupation with appearance and self-esteem pre-procedure and 1 month post-procedure. Additionally, 100 female healthy control participants were recruited as a comparative group into this study and they were also assessed using BDDE, MBSRQ-AS, and RSE-S. A total of 14.2 % of 106 aesthetic patients and 1 % of 100 healthy controls were diagnosed with BDD to varying extents. BDDE scores were 72.83 (SD ± 30.7) and 68.18 (SD ± 31.82), respectively, before and after the procedure for the aesthetic patient group and 43.44 (SD ± 15.65) for the healthy control group (F = 34.28; p aesthetic patients (pre-procedure) and female adult norms from

  8. Postoperative Complications of Beger Procedure

    Directory of Open Access Journals (Sweden)

    Nayana Samejima Peternelli

    2015-01-01

    Full Text Available Introduction. Chronic pancreatitis (CP is considered an inflammatory disease that may cause varying degrees of pancreatic dysfunction. Conservative and surgical treatment options are available depending on dysfunction severity. Presentation of Case. A 36-year-old male with history of heavy alcohol consumption and diagnosed CP underwent a duodenal-preserving pancreatic head resection (DPPHR or Beger procedure after conservative treatment failure. Refractory pain was reported on follow-up three months after surgery and postoperative imaging uncovered stones within the main pancreatic duct and intestinal dilation. The patient was subsequently subjected to another surgical procedure and intraoperative findings included protein plugs within the main pancreatic duct and pancreaticojejunal anastomosis stricture. A V-shaped enlargement and main pancreatic duct dilation in addition to the reconstruction of the previous pancreaticojejunal anastomosis were performed. The patient recovered with no further postoperative complications in the follow-up at an outpatient clinic. Discussion. Main duct and pancreaticojejunal strictures are an unusual complication of the Beger procedure but were identified intraoperatively as the cause of patient’s refractory pain and explained intraductal protein plugs accumulation. Conclusion. Patients that undergo Beger procedures should receive close outpatient clinical follow-up in order to guarantee postoperative conservative treatment success and therefore guarantee an early detection of postoperative complications.

  9. Evaluation of the computerized procedures Manual II (COPMA II)

    International Nuclear Information System (INIS)

    Converse, S.A.

    1995-11-01

    The purpose of this study was to evaluate the effects of a computerized procedure system, the Computerized Procedure Manual II (COPMA-II), on the performance and mental workload of licensed reactor operators. To evaluate COPMA-II, eight teams of two operators were trained to operate a scaled pressurized water reactor facility (SPWRF) with traditional paper procedures and with COPMA-II. Following training, each team operated the SPWRF under normal operating conditions with both paper procedures and COPMA-II. The teams then performed one of two accident scenarios with paper procedures, but performed the remaining accident scenario with COPMA-II. Performance measures and subjective estimates of mental workload were recorded for each performance trial. The most important finding of the study was that the operators committed only half as many errors during the accident scenarios with COPMA-II as they committed with paper procedures. However, time to initiate a procedure was fastest for paper procedures for accident scenario trials. For performance under normal operating conditions, there was no difference in time to initiate or to complete a procedure, or in the number of errors committed with paper procedures and with COPMA-II. There were no consistent differences in the mental workload ratings operators recorded for trials with paper procedures and COPMA-II

  10. Safety and application of procedures or: how do ''they'' have to use operating procedures in nuclear power plants

    International Nuclear Information System (INIS)

    Dien, Y.

    1993-03-01

    Emergency procedures are inescapable aspects of safety. They can be seen as the laws to be respected in an accident situation. But as for all laws, there remains the problem of their application: should strict adherence to the procedure be imposed under all circumstances. Is this possible. Are there any potential risks with such a requirement. Or, on the contrary, should application be more ''open'', more flexible, allowing for adaptation to the actual situation. But what are the potential risks involved in this approach. Are these two approaches to the application of procedures mutually exclusive, or are they complementary. This paper analyzes the nature of the problem of application of procedures and proposes orientations for further thought on the matter. (author). 11 refs

  11. The operators' non-compliance behavior to conduct emergency operating procedures--comparing with the work experience and the complexity of procedural steps

    International Nuclear Information System (INIS)

    Park, Jinkyun; Jung, Wondea

    2003-01-01

    Many kinds of procedures have been used to reduce the operators' workload throughout various industries, such as in the aviation, the chemical and the nuclear industry. It is remarkable that, however, significant portion of accidents or incidents was caused by procedure related human error due to non-compliance of procedures. In this study, to investigate the operators' non-compliance behavior, emergency-training records were collected using a full scope simulator. And three types of the operators' behavior (such as strict adherence, skipping redundant actions and modifying action sequences) observed from collected emergency training records were compared with both their work experience and the complexity of procedural steps. As the results, three remarkable relationships are obtained. They are: (1) the operators who have an intermediate work experience seem to frequently adopt non-compliance behavior to conduct the procedural steps, (2) the operators seem to frequently adopt non-compliance behavior to conduct the procedural steps that have an intermediate procedural complexity, and (3) the senior reactor operators seem to accommodate their non-compliance behavior based on the complexity of procedural steps. Therefore, it is expected that these relationships can be used as meaningful clues not only to scrutinize the reason for non-compliance behavior but also to suggest appropriate remedies for the reduction of non-compliance behavior that can result in procedure related human error

  12. Conception, definition, measuring procedure of grain size

    International Nuclear Information System (INIS)

    Yanagisawa, Kazuaki

    1976-12-01

    The conception, definition, measuring procedure of ''Grain Size'' were surveyed. A concept ''grain diameter'' was introduced after deriving a calculation formula for the grain diameter for using the Comparison (simple) and Intercept(detailed) procedure. As an example and putting into practice, the grain diameter determination was carried out by means of the Comparison procedure for a UO 2 pellet used in a densification experiment. (auth.)

  13. A new tool for the evaluation of the analytical procedure: Green Analytical Procedure Index.

    Science.gov (United States)

    Płotka-Wasylka, J

    2018-05-01

    A new means for assessing analytical protocols relating to green analytical chemistry attributes has been developed. The new tool, called GAPI (Green Analytical Procedure Index), evaluates the green character of an entire analytical methodology, from sample collection to final determination, and was created using such tools as the National Environmental Methods Index (NEMI) or Analytical Eco-Scale to provide not only general but also qualitative information. In GAPI, a specific symbol with five pentagrams can be used to evaluate and quantify the environmental impact involved in each step of an analytical methodology, mainly from green through yellow to red depicting low, medium to high impact, respectively. The proposed tool was used to evaluate analytical procedures applied in the determination of biogenic amines in wine samples, and polycyclic aromatic hydrocarbon determination by EPA methods. GAPI tool not only provides an immediately perceptible perspective to the user/reader but also offers exhaustive information on evaluated procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. [Mood induction procedures: a critical review].

    Science.gov (United States)

    Gilet, A-L

    2008-06-01

    For a long period in the history of psychological research, emotion and cognition have been studied independently, as if one were irrelevant to the other. The renewed interest of researchers for the study of the relations between cognition and emotion has led to the development of a range of laboratory methods for inducing temporary mood states. This paper aims to review the main mood induction procedures allowing the induction of a negative mood as well as a positive mood, developed since the pioneer study of Schachter and Singer [Psychol Rev 69 (1962) 379-399] and to account for the usefulness and problems related to the use of such techniques. The first part of this paper deals with the detailed presentation of some of the most popular mood induction procedures according to their type: simple (use of only one mood induction technique) or combined (association of two or more techniques at once). The earliest of the modern techniques is the Velten Mood Induction Procedure [Behav Res Ther 6 (1968) 473-482], which involves reading aloud sixty self-referent statements progressing from relative neutral mood to negative mood or dysphoria. Some researchers have varied the procedure slightly by changing the number of the statements [Behav Res Ther 21 (1983) 233-239, Br J Clin Psychol 21 (1982) 111-117, J Pers Soc Psychol 35 (1977) 625-636]. Various other mood induction procedures have been developed including music induction [Cogn Emotion 11 (1997) 403-432, Br J Med Psychol 55 (1982) 127-138], film clip induction [J Pers Soc Psychol 20 (1971) 37-43, Cogn Emotion 7 (1993) 171-193, Rottenberg J, Ray RR, Gross JJ. Emotion elicitation using films. In: Coan JA, Allen JJB, editors. The handbook of emotion elicitation and assessment. New York: Oxford University Press, 2007], autobiographical recall [J Clin Psychol 36 (1980) 215-226, Jallais C. Effets des humeurs positives et négatives sur les structures de connaissances de type script. Thèse de doctorat non publi

  15. Development of ISA procedure for uranium fuel fabrication and enrichment facilities: overview of ISA procedure and its application

    International Nuclear Information System (INIS)

    Yamate, Kazuki; Yamada, Takashi; Takanashi, Mitsuhiro; Sasaki, Noriaki

    2013-01-01

    Integrated Safety Analysis (ISA) procedure for uranium fuel fabrication and enrichment facilities has been developed for aiming at applying risk-informed regulation to these uranium facilities. The development has carried out referring to the ISA (NUREG-1520) by the Nuclear Regulatory Commission (NRC). The paper presents purpose, principles and activities for the development of the ISA procedure, including Risk Level (RL) matrix and grading evaluation method of IROFS (Items Relied on for Safety), as well as general description and features of the procedure. Also described in the paper is current status in application of risk information from the ISA. Japanese four licensees of the uranium facilities have been conducting ISA for their representative processes using the developed procedure as their voluntary safety activities. They have been accumulating experiences and knowledge on the ISA procedure and risk information through the field activities. NISA (Nuclear and Industrial Safety Agency) and JNES (Japan Nuclear Energy Safety Organization) are studying how to use such risk information for the safety regulation of the uranium facilities, taking into account the licensees' experiences and knowledge. (authors)

  16. 22 CFR 226.71 - Closeout procedures.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Closeout procedures. 226.71 Section 226.71 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS After-the-Award Requirements § 226.71 Closeout procedures. (a) Recipients shall...

  17. 48 CFR 17.504 - Ordering procedures.

    Science.gov (United States)

    2010-10-01

    ... METHODS AND CONTRACT TYPES SPECIAL CONTRACTING METHODS Interagency Acquisitions Under the Economy Act 17.504 Ordering procedures. (a) Before placing an Economy Act order for supplies or services with another...; see also 6.302 for procedures to follow where using other than full and open competition.) The...

  18. 8 CFR 270.2 - Enforcement procedures.

    Science.gov (United States)

    2010-01-01

    ... Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION REGULATIONS PENALTIES FOR DOCUMENT FRAUD § 270.2 Enforcement procedures. (a) Procedures for the filing of complaints. Any person or entity... charges for document fraud committed by refugees at the time of entry. The Service shall not issue a...

  19. 9 CFR 381.311 - Recall procedure.

    Science.gov (United States)

    2010-01-01

    ... CERTIFICATION POULTRY PRODUCTS INSPECTION REGULATIONS Canning and Canned Products § 381.311 Recall procedure... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Recall procedure. 381.311 Section 381.311 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY...

  20. 47 CFR 13.209 - Examination procedures.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Examination procedures. 13.209 Section 13.209 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL RADIO OPERATORS Examination System § 13.209 Examination procedures. (a) Each examination for a commercial radio operator license must be administered at a...

  1. 44 CFR 208.52 - Reimbursement procedures.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Reimbursement procedures. 208... Reimbursement Claims and Appeals § 208.52 Reimbursement procedures. (a) General. A Sponsoring Agency must present a claim for reimbursement to DHS in such manner as the Assistant Administrator specifies . (b...

  2. 10 CFR 474.4 - Test procedures.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Test procedures. 474.4 Section 474.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ELECTRIC AND HYBRID VEHICLE RESEARCH, DEVELOPMENT, AND DEMONSTRATION PROGRAM; PETROLEUM-EQUIVALENT FUEL ECONOMY CALCULATION § 474.4 Test procedures. (a) The electric vehicle energy...

  3. Procedural virtual reality simulation in minimally invasive surgery.

    Science.gov (United States)

    Våpenstad, Cecilie; Buzink, Sonja N

    2013-02-01

    Simulation of procedural tasks has the potential to bridge the gap between basic skills training outside the operating room (OR) and performance of complex surgical tasks in the OR. This paper provides an overview of procedural virtual reality (VR) simulation currently available on the market and presented in scientific literature for laparoscopy (LS), flexible gastrointestinal endoscopy (FGE), and endovascular surgery (EVS). An online survey was sent to companies and research groups selling or developing procedural VR simulators, and a systematic search was done for scientific publications presenting or applying VR simulators to train or assess procedural skills in the PUBMED and SCOPUS databases. The results of five simulator companies were included in the survey. In the literature review, 116 articles were analyzed (45 on LS, 43 on FGE, 28 on EVS), presenting a total of 23 simulator systems. The companies stated to altogether offer 78 procedural tasks (33 for LS, 12 for FGE, 33 for EVS), of which 17 also were found in the literature review. Although study type and used outcomes vary between the three different fields, approximately 90 % of the studies presented in the retrieved publications for LS found convincing evidence to confirm the validity or added value of procedural VR simulation. This was the case in approximately 75 % for FGE and EVS. Procedural training using VR simulators has been found to improve clinical performance. There is nevertheless a large amount of simulated procedural tasks that have not been validated. Future research should focus on the optimal use of procedural simulators in the most effective training setups and further investigate the benefits of procedural VR simulation to improve clinical outcome.

  4. Patient radiation doses from neuroradiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Roman, M J; Abreu-Luis, J; Hernandez-Armas, J [Servicio de Fisica Medica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Prada-Martinez, E [Servicio de Radiodiagnostico, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain)

    2001-03-01

    Following the presentation of radiation-induced deterministic effects by some patients undergoing neuroradiological procedures during successive sessions, such as temporary epilation, in the 'Hospital Universitario de Canarias', measurements were made of dose to patients. The maximum dose-area product measured by ionization chamber during these procedures was 39617 cGy.cm{sup 2} in a diagnostic of aneurysm and the maximum dose to the skin measured by thermoluminescent dosemeters (TLDs) was 462.53 mGy. This can justify certain deterministic effects but it is unlikely that the patients will suffer serious effects from this skin dose. Also, measurements were made of effective dose about two usual procedures, embolisation of tumour und embolisation of aneurysm. These procedures were reproduced with an anthropomorphic phantom Rando and doses were measured with TLDs. Effective doses obtained were 3.79 mSv and 4.11 mSv, respectively. The effective dose valued by the program EFFDOSE was less than values measured with TLDs. (author)

  5. Patient radiation doses from neuroradiology procedures

    International Nuclear Information System (INIS)

    Garcia-Roman, M.J.; Abreu-Luis, J.; Hernandez-Armas, J.; Prada-Martinez, E.

    2001-01-01

    Following the presentation of radiation-induced deterministic effects by some patients undergoing neuroradiological procedures during successive sessions, such as temporary epilation, in the 'Hospital Universitario de Canarias', measurements were made of dose to patients. The maximum dose-area product measured by ionization chamber during these procedures was 39617 cGy.cm 2 in a diagnostic of aneurysm and the maximum dose to the skin measured by thermoluminescent dosemeters (TLDs) was 462.53 mGy. This can justify certain deterministic effects but it is unlikely that the patients will suffer serious effects from this skin dose. Also, measurements were made of effective dose about two usual procedures, embolisation of tumour und embolisation of aneurysm. These procedures were reproduced with an anthropomorphic phantom Rando and doses were measured with TLDs. Effective doses obtained were 3.79 mSv and 4.11 mSv, respectively. The effective dose valued by the program EFFDOSE was less than values measured with TLDs. (author)

  6. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  7. OCRWM international procedures

    International Nuclear Information System (INIS)

    1986-03-01

    These international procedures provide guidance and assistance for the Office of Civilian Radioactive Waste Management (OCRWM) and for OCRWM Project Offices, contractors and subcontractors in conducting international activities. They supplement the relevant Department of Energy (DOE) orders (which are referenced), not supplant them

  8. PENILE ENHANCEMENT PROCEDURES: UROLOGICAL AND ETHICOLEGAL ISSUES

    Directory of Open Access Journals (Sweden)

    Marco Vella

    2012-04-01

    Full Text Available Phalloplasty procedures for most men requiring penile augmentation surgery are cosmetic procedures; generally the patients have a normal-sized and fully functional penis but they think that their penis is too small. There are not well defined indications for penile enhancement surgery and, except for the treatment of “micropenis”, there are not established guidelines and the outcome measures for success are still unclear. All penile enhancement techniques often do not reach the expected result and the grade of patient’s satisfaction is frequently poor. Phalloplasty procedures for psychological dysmorfism are not approved by any scientific society and the majority of these procedures are performed in private settings. The ethical and medicolegal problems resulting from a penis enhancement can be various and numerous, but few of them are reported in literature. After phalloplasty an attribution of professional responsibility and request of reimbursement is not rare. In this contribution the authors summarize a panorama of several urological and medico-legal aspects related to phalloplasty procedures.

  9. Quality procedure management for improved nuclear safety

    International Nuclear Information System (INIS)

    Forzano, P.; Castagna, P.

    1995-01-01

    Emergency Operating Procedures and Accident Management Procedures are the next step in the computerization of NPP control rooms. Different improvements are presently conceivable for this operator aid tool, and research activities are in development. Undergoing activities regard especially formal aspects of knowledge representation, Human-Machine interface and procedure life cycle management. These aspects have been investigated deeply by Ansaldo, and partially incorporated in the DIAM prototype. Nuclear Power Plant Procedures can be seen from essentially two viewpoints: the process and the information management. From the first point of view, it is important to supply the knowledge apt to solve problems connected with the control of the process, from the second one the focus of attention is on the knowledge representation, its structure, elicitation and maintenance, and formal quality assurance. These two aspects of procedure representation can be considered and solved separately. In particular, methodological, formal and management issues require long and tedious activities, that in most cases constitute a great barrier for procedures development and upgrade. To solve these problems, Ansaldo is developing DIAM, a wide integrated tool for procedure management to support in procedure writing, updating, usage, and documentation. One of the most challenging features of DIAM is AUTO-LAY, a CASE sub-tool that, in a complete automatical way, structures parts or complete flow diagram. This is the feature that is partial present in some other CASE products, that, anyway, do not allow complex graph handling and isomorphism between video and paper representation. AUTO-LAY has the unique prerogative to draw graphs of any complexity to section them in pages, and to automatically compose a document. This has been recognized in the literature as the most important a second-generation CASE improvement. (Author) 9 Figs., 5 Refs

  10. 76 FR 15368 - Minimum Security Devices and Procedures

    Science.gov (United States)

    2011-03-21

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision Minimum Security Devices and Procedures... concerning the following information collection. Title of Proposal: Minimum Security Devices and Procedures... security devices and procedures to discourage robberies, burglaries, and larcenies, and to assist in the...

  11. 32 CFR 623.4 - Accounting procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Accounting procedures. 623.4 Section 623.4... ARMY MATERIEL § 623.4 Accounting procedures. (a) Loan document format. (1) When the lending accountable... property accounting purposes. (3) Loans will be processed by accountable property officers according to...

  12. 5 CFR 339.303 - Examination procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Examination procedures. 339.303 Section... QUALIFICATION DETERMINATIONS Medical Examinations § 339.303 Examination procedures. (a) When an agency orders or offers a medical examination under this subpart, it must inform the applicant or employee in writing of...

  13. 22 CFR 92.37 - Authentication procedure.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Authentication procedure. 92.37 Section 92.37... Notarial Acts § 92.37 Authentication procedure. (a) The consular officer must compare the foreign official...) Where the State law requires the consular officer's certificate of authentication to show that the...

  14. The Performative Uses of the Surveillance Archive in Manu Luksch's Works

    DEFF Research Database (Denmark)

    Thomsen, Bodil Marie Stavning

    2013-01-01

    This article discusses Manu Luksch's works using CCTV recordings as an example of aesthetic intervention in contemporary surveillance systems. Luksch's works are read as a “critical interface" between the artist's body and the archiving procedures of surveillance systems....

  15. Creating Online Training for Procedures in Global Health with PEARLS (Procedural Education for Adaptation to Resource-Limited Settings).

    Science.gov (United States)

    Bensman, Rachel S; Slusher, Tina M; Butteris, Sabrina M; Pitt, Michael B; On Behalf Of The Sugar Pearls Investigators; Becker, Amanda; Desai, Brinda; George, Alisha; Hagen, Scott; Kiragu, Andrew; Johannsen, Ron; Miller, Kathleen; Rule, Amy; Webber, Sarah

    2017-11-01

    The authors describe a multiinstitutional collaborative project to address a gap in global health training by creating a free online platform to share a curriculum for performing procedures in resource-limited settings. This curriculum called PEARLS (Procedural Education for Adaptation to Resource-Limited Settings) consists of peer-reviewed instructional and demonstration videos describing modifications for performing common pediatric procedures in resource-limited settings. Adaptations range from the creation of a low-cost spacer for inhaled medications to a suction chamber for continued evacuation of a chest tube. By describing the collaborative process, we provide a model for educators in other fields to collate and disseminate procedural modifications adapted for their own specialty and location, ideally expanding this crowd-sourced curriculum to reach a wide audience of trainees and providers in global health.

  16. Factors Affecting Patient Satisfaction During Endoscopic Procedures

    International Nuclear Information System (INIS)

    Qureshi, M. O.; Shafqat, F.; Ahmed, S.; Niazi, T. K.; Khokhar, N. K.

    2013-01-01

    Objective: To assess the quality and patient satisfaction in Endoscopy Unit of Shifa International Hospital. Study Design: Cross-sectional survey. Place and Duration of Study: Division of Gastroenterology, Shifa International Hospital, Islamabad, Pakistan, from July 2011 to January 2012. Methodology: Quality and patient satisfaction after the endoscopic procedure was assessed using a modified GHAA-9 questionnaire. Data was analyzed using SPSS version 16. Results: A total of 1028 patients were included with a mean age of 45 A+- 14.21 years. Out of all the procedures, 670 (65.17%) were gastroscopies, 181 (17.60%) were flexible sigmoidoscopies and 177 (17.21%) were colonoscopies. The maximum unsatisfactory responses were on the waiting time before the procedure (13.13 %), followed by unsatisfactory explanation of the procedure and answers to questions (7.58%). Overall, unsatisfied impression was 4.86%. The problem rate was 6.22%. Conclusion: The quality of procedures and level of satisfaction of patients undergoing a gastroscopy or colonoscopy was generally good. The factors that influence the satisfaction of these patients are related to communication between doctor and patient, doctor's manner and waiting time for the procedure. Feedback information in an endoscopy unit may be useful in improving standards, including the performance of endoscopists. (author)

  17. Vision based flight procedure stereo display system

    Science.gov (United States)

    Shen, Xiaoyun; Wan, Di; Ma, Lan; He, Yuncheng

    2008-03-01

    A virtual reality flight procedure vision system is introduced in this paper. The digital flight map database is established based on the Geographic Information System (GIS) and high definitions satellite remote sensing photos. The flight approaching area database is established through computer 3D modeling system and GIS. The area texture is generated from the remote sensing photos and aerial photographs in various level of detail. According to the flight approaching procedure, the flight navigation information is linked to the database. The flight approaching area vision can be dynamic displayed according to the designed flight procedure. The flight approaching area images are rendered in 2 channels, one for left eye images and the others for right eye images. Through the polarized stereoscopic projection system, the pilots and aircrew can get the vivid 3D vision of the flight destination approaching area. Take the use of this system in pilots preflight preparation procedure, the aircrew can get more vivid information along the flight destination approaching area. This system can improve the aviator's self-confidence before he carries out the flight mission, accordingly, the flight safety is improved. This system is also useful in validate the visual flight procedure design, and it helps to the flight procedure design.

  18. A Survey on Procedural Modelling for Virtual Worlds

    NARCIS (Netherlands)

    Smelik, R.M.; Tutenel, T.; Bidarra, R.; Benes, B.

    2014-01-01

    Procedural modelling deals with (semi-)automatic content generation by means of a program or procedure. Among other advantages, its data compression and the potential to generate a large variety of detailed content with reduced human intervention, have made procedural modelling attractive for

  19. Experiences with a procedure for modeling product knowledge

    DEFF Research Database (Denmark)

    Hansen, Benjamin Loer; Hvam, Lars

    2002-01-01

    This paper presents experiences with a procedure for building configurators. The procedure has been used in an American company producing custom-made precision air conditioning equipment. The paper describes experiences with the use of the procedure and experiences with the project in general....

  20. 76 FR 30243 - Minimum Security Devices and Procedures

    Science.gov (United States)

    2011-05-24

    ... DEPARTMENT OF THE TREASURY Office of Thrift Supervision Minimum Security Devices and Procedures.... Title of Proposal: Minimum Security Devices and Procedures. OMB Number: 1550-0062. Form Number: N/A... respect to the installation, maintenance, and operation of security devices and procedures to discourage...

  1. Interim Reliability Evaluation Program procedures guide

    International Nuclear Information System (INIS)

    Carlson, D.D.; Gallup, D.R.; Kolaczkowski, A.M.; Kolb, G.J.; Stack, D.W.; Lofgren, E.; Horton, W.H.; Lobner, P.R.

    1983-01-01

    This document presents procedures for conducting analyses of a scope similar to those performed in Phase II of the Interim Reliability Evaluation Program (IREP). It documents the current state of the art in performing the plant systems analysis portion of a probabilistic risk assessment. Insights gained into managing such an analysis are discussed. Step-by-step procedures and methodological guidance constitute the major portion of the document. While not to be viewed as a cookbook, the procedures set forth the principal steps in performing an IREP analysis. Guidance for resolving the problems encountered in previous analyses is offered. Numerous examples and representative products from previous analyses clarify the discussion

  2. Acute Procedural Pain in Children

    DEFF Research Database (Denmark)

    Kristensen, Helle Nygård; Lundbye-Christensen, Søren; Haslund-Thomsen, Helle

    2018-01-01

    INTRODUCTION: Hospitalized children often describe needle-related procedures as the worst pain possible and such procedures may be emotionally traumatic. The use of hospital clowns related to painful medical procedures in children may offer pain relief, but this has not been systematically...... evaluated. The objective of this study was to assess the effect of a therapeutic clown in comparison to standard care on the experience of pain for children receiving venipuncture. METHODS: A sample of 116 children aged 4-15 years consecutively admitted to the hospital was allocated to either......: Without the clown present, the mean pain score (2.7±2.8) was not significantly different between the two age groups. Children aged 7-15 years had lower pain scores when the clown was present compared to the control group (P=0.025). Children aged 4-6 years had higher pain scores with the clown present...

  3. Radiation control standards and procedures

    Energy Technology Data Exchange (ETDEWEB)

    1956-12-14

    This manual contains the Radiation Control Standards'' and Radiation Control Procedures'' at Hanford Operations which have been established to provide the necessary control radiation exposures within Irradiation Processing Department. Provision is also made for including, in the form of Bulletins'', other radiological information of general interest to IPD personnel. The purpose of the standards is to establish firm radiological limits within which the Irradiation Processing Department will operate, and to outline our radiation control program in sufficient detail to insure uniform and consistent application throughout all IPD facilities. Radiation Control Procedures are intended to prescribe the best method of accomplishing an objective within the limitations of the Radiation Control Standards. A procedure may be changed at any time provided the suggested changes is generally agreeable to management involved, and is consistent with department policies and the Radiation Control Standards.

  4. [Evaluation of ergonomic load of clinical nursing procedures].

    Science.gov (United States)

    Yan, P; Zhang, L; Li, F Y; Yang, Y; Wang, Y N; Huang, A M; Dai, Y L; Yao, H

    2017-08-20

    Objective: To evaluate the ergonomic load of clinical nursing procedures and to provide evidence for the prevention and management of work-related musculoskeletal disorders (WMSDs) in nurses. Methods: Based on the nursing unit characteristics and the common departments involving patient-turning procedures, 552 nurses were selected from 6 clinical departments from July to September, 2016. The ergonomic load of four types of patient-turning procedures, i.e., turning the patient's body, changing the bed linen of in-bed patients, moving patients, and chest physiotherapy, was evaluated by the on-site inspectors and self-evaluated by the operators using the Quick Exposure Check. The exposure value, exposure level, and exposure rate of WMSDs were assessed based on the procedure-related physical loads on the back, shoulders/arms, wrists/hands and neck, as well as the loads from work rhythm and work pressure. Results: All surveyed subjects were females who were aged mostly between 26-30 years (49.46%) , with a mean age of 29.66±5.28 years. These nurses were mainly from the Department of Infection (28.99%) and Spine Surgery (21.56%) . There were significant differences in the back, shoulders/arms, neck, work rhythm, and work pressure scores between different nursing procedures ( F =16.613, 5.884, 3.431, 3.222, and 5.085, respectively; P nursing procedures resulted in high to intermediate physical load in nurses. Procedures with high to low level of WMSDs exposure were patient turning (72.69%) , bed linen changing (67.15%) , patient transfer (65.82%) , and chest physiotherapy (58.34%) . In particular, patient turning was considered as very high-risk procedure, whereas others were considered as high-risk procedures. Conclusion: Patient-turning nursing procedures result in high ergonomic load in the operators. Therefore, more focus should be placed on the ergonomics of the caretakers and nurses.

  5. 22 CFR 92.60 - Examination procedures.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Examination procedures. 92.60 Section 92.60... and Letters Rogatory § 92.60 Examination procedures. (a) Explaining interrogatory to witness. If the... examination of a witness propound such inquiries as may be necessary to satisfy himself whether the witness is...

  6. 37 CFR 1.809 - Examination procedures.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Examination procedures. 1.809... Biological Material § 1.809 Examination procedures. (a) The examiner shall determine pursuant to § 1.104 in... deposited biological material sufficient to specifically identify it and to permit examination; and (4) The...

  7. 12 CFR 411.405 - Penalty procedures.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Penalty procedures. 411.405 Section 411.405 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES NEW RESTRICTIONS ON LOBBYING Penalties and Enforcement § 411.405 Penalty procedures. Agencies shall impose and collect civil penalties pursuant to the...

  8. 50 CFR 85.21 - Application procedures.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Application procedures. 85.21 Section 85... Application for Grants § 85.21 Application procedures. (a) Eligible applicants will submit their proposals to..., Missouri, Ohio, and Wisconsin Division of Federal Aid, U.S. Fish and Wildlife Service, Bishop Henry Whipple...

  9. 45 CFR 708.7 - Hearing procedures.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Hearing procedures. 708.7 Section 708.7 Public Welfare Regulations Relating to Public Welfare (Continued) COMMISSION ON CIVIL RIGHTS COLLECTION BY SALARY OFFSET FROM INDEBTED CURRENT AND FORMER EMPLOYEES § 708.7 Hearing procedures. (a) If an employee timely...

  10. Judicial civil procedure dragging out in Kosovo

    Directory of Open Access Journals (Sweden)

    Rrustem Qehaja

    2016-03-01

    Full Text Available This article tends to deal with one of the most worrying issues in the judicial system of Kosovo the problem of judicial civil procedure dragging out. The article analyses the reasons of these dragging outs of the judicial civil procedure focusing on the context of one of the basic procedural principles in civil procedure-the principle of economy or efficiency in the courts. Dragging out of civil procedure in Kosovo has put in question not only the basic principles of civil procedure, but it also challenges the general principles related to human rights and freedoms sanctioned not only by the highest legal act of the country, but also with international treaties. The article tends to give a reflection to the most important reasons that effect and influence in these dragging outs of civil procedure, as well as, at the same time aims to give the necessary alternatives to pass through them by identifying dilemmas within the judicial practice. As a result, the motives of this scientific paper are exactly focused at the same time on identifying the dilemmas, as well as presenting ideas, to overstep them, including the judicial practice of the European Court of Human Rights on Article 6 of the European Convention on Human Rights, by which it is given the possibility to offering people efficient and within a reasonable time legal protection of their rights before national courts. For these reasons, the paper elaborates this issue based on both, the legal theory and judicial practice.

  11. The computerised procedure system COPMA and its user interface

    International Nuclear Information System (INIS)

    Krogsaeter, M.; Larsen, J.; Nilsen, S.; Oewre, F.

    1990-01-01

    At the OECD Halden Reactor Project, the COPMA system has been developed in order to investigate whether procedures can be executed more safety and efficiently if they are computerised, i.e. if the operator uses a CRT-based system instead of written manuals. Procedures are entered in a procedure data base using PED, a procedure editor. Each procedure is given a textual as well as a graphical representation. For the textual representation, the language PROLA is used, a language which has been designed for simple procedure specification. The COPMA online system lets the operator execute procedures that are stored in the procedure data base. The operator interface is a screen divided into non-overlapping windows each serving a different purpose. All commands to the system are given by moving a mouse device around and clicking buttons on top of the mouse. A procedure consists of steps, each step containing a number of instructions. The operator works on one activity at a time, an activity to be seen as a procedure instance. A graph shows the overall procedure (or activity) structure in a window and activity execution is traced in the graph. Another windows shows the instructions of the step currently being executed. The operator steps through the activity by selecting whether and how to execute the listed instructions. COPMA can maintain the status of several activities in parallel, so that the operator can easily switch between different activities. COPMA is linked to a PWR nuclear simulator over Ethernet using the TCP/IP protocol. This gives a number of advantages as compared to conventional written procedures, especially the fact that COPMA can help collect data from the procedure data base automatically

  12. 21 CFR 120.6 - Sanitation standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sanitation standard operating procedures. 120.6... Provisions § 120.6 Sanitation standard operating procedures. (a) Sanitation controls. Each processor shall have and implement a sanitation standard operating procedure (SSOP) that addresses sanitation...

  13. 7 CFR 1940.406 - Real estate settlement procedures.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Real estate settlement procedures. 1940.406 Section... AGRICULTURE (CONTINUED) PROGRAM REGULATIONS (CONTINUED) GENERAL Truth in Lending-Real Estate Settlement Procedures § 1940.406 Real estate settlement procedures. (a) General. This section provides the instructions...

  14. Smoking Habit in Severe Obese after bariatric procedures.

    Science.gov (United States)

    Maniscalco, Mauro; Carratù, Pierluigi; Faraone, Stanislao; Cerbone, Maria Rosaria; Cristiano, Stefano; Zedda, Anna; Resta, Onofrio

    2015-01-01

    Bariatric procedures provide an effective means of short term weight loss and sustained weight control for the morbidly obese. The effect of bariatric procedures on smoking habit in obese subjects is not well known. Therefore, we examined the short term effect of bariatric surgery on smoking habit of severe obese patients up to 12 months from the intervention. Smoking habit was assessed in a cohort of 78 morbid smoking obese patients followed at our clinic for bariatric procedures. They underwent non surgical intra-gastric balloon (IB) or surgical procedures such as lap-band laparoscopic surgery (LAGB) or sleeve gastrectomy/gastric by-pass (SPG). Subjects were administered a written questionnaire about their smoking habit before and 3, 6 and 12 months after the procedures. No differences were found among the three groups at 6 and 12 months after the procedures (IB 21 %, LAGB 6 %, SPG 5 %; and IB 14 %, LAGB 3 %, SPG 5 %). Only after 3 months, the rate of quitting of the IB group was higher than LAGB and SPG groups (36 %, 6 % and 5 %, respectively; p = 0.02). Bariatric procedures have no effects on smoking habit of moderate-to-heavy smoker severe obese patients. The use of other traditional smoking cessation methods in patients undergone to bariatric procedures should be implemented.

  15. Cloud-based Electronic Test Procedures, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Test procedures are at the heart of any experimental process, especially those involving novel and complex hardware. Whether these procedures are for system...

  16. Current procedural terminology; a primer.

    Science.gov (United States)

    Hirsch, Joshua A; Leslie-Mazwi, Thabele M; Nicola, Gregory N; Barr, Robert M; Bello, Jacqueline A; Donovan, William D; Tu, Raymond; Alson, Mark D; Manchikanti, Laxmaiah

    2015-04-01

    In 1966, The American Medical Association (AMA) working with multiple major medical specialty societies developed an iterative coding system for describing medical procedures and services using uniform language, the Current Procedural Terminology (CPT) system. The current code set, CPT IV, forms the basis of reporting most of the services performed by healthcare providers, physicians and non-physicians as well as facilities allowing effective, reliable communication among physician and other providers, third parties and patients. This coding system and its maintenance has evolved significantly since its inception, and now goes well beyond its readily perceived role in reimbursement. Additional roles include administrative management, tracking new and investigational procedures, and evolving aspects of 'pay for performance'. The system also allows for local, regional and national utilization comparisons for medical education and research. Neurointerventional specialists use CPT category I codes regularly--for example, 36,215 for first-order cerebrovascular angiography, 36,216 for second-order vessels, and 37,184 for acute stroke treatment by mechanical means. Additionally, physicians add relevant modifiers to the CPT codes, such as '-26' to indicate 'professional charge only,' or '-59' to indicate a distinct procedural service performed on the same day. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Comparison of transition-matrix sampling procedures

    DEFF Research Database (Denmark)

    Yevick, D.; Reimer, M.; Tromborg, Bjarne

    2009-01-01

    We compare the accuracy of the multicanonical procedure with that of transition-matrix models of static and dynamic communication system properties incorporating different acceptance rules. We find that for appropriate ranges of the underlying numerical parameters, algorithmically simple yet high...... accurate procedures can be employed in place of the standard multicanonical sampling algorithm....

  18. 27 CFR 44.227 - Customs procedure.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Customs procedure. 44.227..., WITHOUT PAYMENT OF TAX, OR WITH DRAWBACK OF TAX Drawback of Tax § 44.227 Customs procedure. The customs... having inspected the articles and supervised the lading thereof on the export carrier, the customs...

  19. Identifying cognitive complexity factors affecting the complexity of procedural steps in emergency operating procedures of a nuclear power plant

    International Nuclear Information System (INIS)

    Park, Jinkyun; Jeong, Kwangsup; Jung, Wondea

    2005-01-01

    In complex systems such as a nuclear and chemical plant, it is well known that the provision of understandable procedures that allow operators to clarify what needs to be done and how to do it is one of the requisites to secure their safety. As a previous study in providing understandable procedures, the step complexity (SC) measure that can quantify the complexity of procedural steps in emergency operating procedures (EOPs) of a nuclear power plant (NPP) was suggested. However, the necessity of additional complexity factors that can consider a cognitive aspect in evaluating the complexity of procedural steps is raised. To this end, the comparisons between operators' performance data measured by the form of a step performance time with their behavior in carrying out the prescribed activities of procedural steps are conducted in this study. As a result, two kinds of complexity factors (the abstraction level of knowledge and the level of engineering decision) that could affect an operator's cognitive burden are identified. Although a well-designed experiment is indispensable for confirming the appropriateness of the additional complexity factors, it is strongly believed that the change of operators' performance data can be more authentically explained if the additional complexity factors are taken into consideration

  20. Identifying cognitive complexity factors affecting the complexity of procedural steps in emergency operating procedures of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jinkyun [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, P.O. Box 105, Duckjin-Dong, Yusong-Ku, Taejon 305-600 (Korea, Republic of)]. E-mail: kshpjk@kaeri.re.kr; Jeong, Kwangsup [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, P.O. Box 105, Duckjin-Dong, Yusong-Ku, Taejon 305-600 (Korea, Republic of); Jung, Wondea [Integrated Safety Assessment Division, Korea Atomic Energy Research Institute, P.O. Box 105, Duckjin-Dong, Yusong-Ku, Taejon 305-600 (Korea, Republic of)

    2005-08-01

    In complex systems such as a nuclear and chemical plant, it is well known that the provision of understandable procedures that allow operators to clarify what needs to be done and how to do it is one of the requisites to secure their safety. As a previous study in providing understandable procedures, the step complexity (SC) measure that can quantify the complexity of procedural steps in emergency operating procedures (EOPs) of a nuclear power plant (NPP) was suggested. However, the necessity of additional complexity factors that can consider a cognitive aspect in evaluating the complexity of procedural steps is raised. To this end, the comparisons between operators' performance data measured by the form of a step performance time with their behavior in carrying out the prescribed activities of procedural steps are conducted in this study. As a result, two kinds of complexity factors (the abstraction level of knowledge and the level of engineering decision) that could affect an operator's cognitive burden are identified. Although a well-designed experiment is indispensable for confirming the appropriateness of the additional complexity factors, it is strongly believed that the change of operators' performance data can be more authentically explained if the additional complexity factors are taken into consideration.

  1. Identifying cognitive complexity factors affecting the complexity of procedural steps in emergency operating procedures of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Jinkyun Park; Kwangsup Jeong; Wondea Jung [Korea Atomic Energy Research Institute, Taejon (Korea). Integrated Safety Assessment Division

    2005-08-15

    In complex systems such as a nuclear and chemical plant, it is well known that the provision of understandable procedures that allow operators to clarify what needs to be done and how to do it is one of the requisites to secure their safety. As a previous study in providing understandable procedures, the step complexity (SC) measure that can quantify the complexity of procedural steps in emergency operating procedures (EOPs) of a nuclear power plant (NPP) was suggested. However, the necessity of additional complexity factors that can consider a cognitive aspect in evaluating the complexity of procedural steps is raised. To this end, the comparisons between operator' performance data measured by the form of a step performance time with their behavior in carrying out the prescribed activities of procedural steps are conducted in this study. As a result, two kinds of complexity factors (the abstraction level of knowledge and the level of engineering decision) that could affect an operator's cognitive burden are identified. Although a well-designed experiment is indispensable for confirming the appropriateness of the additional complexity factors, it is strongly believed that the change of operators' performance data can be more authentically explained if the additional complexity factors are taken into consideration. (author)

  2. Educational Accounting Procedures.

    Science.gov (United States)

    Tidwell, Sam B.

    This chapter of "Principles of School Business Management" reviews the functions, procedures, and reports with which school business officials must be familiar in order to interpret and make decisions regarding the school district's financial position. Among the accounting functions discussed are financial management, internal auditing,…

  3. The TOMAX-procedure

    NARCIS (Netherlands)

    Overgoor, M.L.E.

    2015-01-01

    Most patients with a low spinal lesion (LSL) have intact erectile function but no penile sensation, which can lead to frustration. To tackle this problem, we designed TOMAX, TOMAXimize sensation, sexuality and quality of life, a surgical procedure in which a functional "groin” nerve is connected to

  4. Procedure Integrated Development Environment (PRIDE), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA captures and distributes operational knowledge in the form of procedures. These procedures are created and accessed by a range of people performing many...

  5. Typical NRC inspection procedures for model plant

    International Nuclear Information System (INIS)

    Blaylock, J.

    1984-01-01

    A summary of NRC inspection procedures for a model LEU fuel fabrication plant is presented. Procedures and methods for combining inventory data, seals, measurement techniques, and statistical analysis are emphasized

  6. 7 CFR 983.52 - Failed lots/rework procedure.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Failed lots/rework procedure. 983.52 Section 983.52..., ARIZONA, AND NEW MEXICO Regulations § 983.52 Failed lots/rework procedure. (a) Substandard pistachios... committee may establish, with the Secretary's approval, appropriate rework procedures. (b) Failed lot...

  7. 10 CFR 71.111 - Instructions, procedures, and drawings.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Instructions, procedures, and drawings. 71.111 Section 71... MATERIAL Quality Assurance § 71.111 Instructions, procedures, and drawings. The licensee, certificate..., procedures, or drawings of a type appropriate to the circumstances and shall require that these instructions...

  8. 45 CFR 1151.43 - Adoption of grievance procedures.

    Science.gov (United States)

    2010-10-01

    ... Enforcement § 1151.43 Adoption of grievance procedures. A recipient may adopt an internal grievance procedure... prohibited by this part. A responsible official should be designated to coordinate the recipient's efforts in connection with this section. Such procedures need not be established with respect to complaints from...

  9. Civil Procedure in Cross-cultural Dialogue: Eurasia Context

    Directory of Open Access Journals (Sweden)

    Stefaan Voet

    2014-01-01

    Full Text Available Reviewed book: Civil Procedure in Cross-cultural Dialogue: Eurasia Context: IAPL World Conference on Civil Procedure, September 18–21, 2012, Moscow, Russia (Dmitry Maleshin, ed. (Statut 2012, available at (accessed March 9, 2014 [hereinafter Civil Procedure in Cross-cultural Dialogue: Eurasia Context].

  10. 77 FR 56698 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-09-13

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  11. 78 FR 66098 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2013-11-04

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  12. 75 FR 22892 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2010-04-30

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  13. 76 FR 59481 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2011-09-26

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  14. 77 FR 2603 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-01-18

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  15. 78 FR 2711 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2013-01-14

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  16. 76 FR 27168 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2011-05-10

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  17. 18 CFR 725.6 - Principles, standards and procedures.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Principles, standards... Responsibilities § 725.6 Principles, standards and procedures. The Principles, Standards and Procedures established... Orders. These Principles, Standards and Procedures are found in 18 CFR parts 710 through 717. ...

  18. Finishing procedures action on mechanical characteristics of pressed ceramics

    Directory of Open Access Journals (Sweden)

    Mohamed Abdel Moniem Ahmed

    2018-06-01

    Conclusions& significance: Grinding & finishing procedures of pressed ceramics showed significant effect Of drill speed and polishing technique over flexural strength, As Grinding with no finishing and polishing procedure showed lowest flexural Strength values followed by finishing and polishing procedure followed by finishing and polishing with polishing paste procedure.

  19. Cancer pancreatis, diagnostic procedures

    International Nuclear Information System (INIS)

    Graadal, Oe.; Schlichting, E.; Aasen, A.O.; Stadaas, J.O.

    1990-01-01

    151 patients treated for carcinoma of the pancreas at Ullevaal Hospital (Oslo University) during the period 1980-89 were studied. The most common initial symptom was abdominal pain. Other frequent debut symptoms were loss of weight and jaundice. ERCP and PTC were found to be the best diagnostic procedures. CT or ultrasonography were normal in 10-20% of the patients. Nearly all tumors of the pancreas were found by the ERCP procedure. Also angiography was used to evaluate operability of the pancreas tumor, but was found to be a very uncertain diagnostic method. This method will not be used in the future evaluation of patients with cancer of the pancreas. 13 refs., 1 fig., 2 tabs

  20. EMP protection procedure for electrical/electronic systems

    International Nuclear Information System (INIS)

    Latorre, V.R.

    1976-01-01

    This paper presents a procedure for the protection engineer to follow in assessing a system with respect to its susceptibility to an electromagnetic pulse (EMP), and in determining whether the system requires protection. If the system is determined to be vulnerable to EMP, the procedure also indicates how to decide upon the most suitable protection scheme. The discussion centers on two flow charts, which illustrate the step-by-step procedure which utilizes the necessary ingredients of EMP protection engineering discussed in a previous paper. The description of the protection procedure is divided into two parts: the first dealing with issues on the macroscopic or large-scale system level, while the second is concerned with operations on the subsystem level or lower

  1. Design Transformations for Rule-based Procedural Modeling

    KAUST Repository

    Lienhard, Stefan; Lau, Cheryl; Mü ller, Pascal; Wonka, Peter; Pauly, Mark

    2017-01-01

    We introduce design transformations for rule-based procedural models, e.g., for buildings and plants. Given two or more procedural designs, each specified by a grammar, a design transformation combines elements of the existing designs to generate new designs. We introduce two technical components to enable design transformations. First, we extend the concept of discrete rule switching to rule merging, leading to a very large shape space for combining procedural models. Second, we propose an algorithm to jointly derive two or more grammars, called grammar co-derivation. We demonstrate two applications of our work: we show that our framework leads to a larger variety of models than previous work, and we show fine-grained transformation sequences between two procedural models.

  2. Design Transformations for Rule-based Procedural Modeling

    KAUST Repository

    Lienhard, Stefan

    2017-05-24

    We introduce design transformations for rule-based procedural models, e.g., for buildings and plants. Given two or more procedural designs, each specified by a grammar, a design transformation combines elements of the existing designs to generate new designs. We introduce two technical components to enable design transformations. First, we extend the concept of discrete rule switching to rule merging, leading to a very large shape space for combining procedural models. Second, we propose an algorithm to jointly derive two or more grammars, called grammar co-derivation. We demonstrate two applications of our work: we show that our framework leads to a larger variety of models than previous work, and we show fine-grained transformation sequences between two procedural models.

  3. 75 FR 78804 - Proposed Collection; Comment Request for Revenue Procedure 2003-45 and Revenue Procedure 2004-48

    Science.gov (United States)

    2010-12-16

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently... Corporations, and Revenue Procedure 2004-48, Deemed Corporate Election for Late Electing S Corporations. DATES...-45, Late Election Relief for S Corporations, and Revenue Procedure 2004-48, Deemed Corporate Election...

  4. 76 FR 44656 - Proposed Collection; Comment Request for Revenue Procedure(s)

    Science.gov (United States)

    2011-07-26

    ... disaffililiation and procedure to eliminate impediments to e-filing consolidated returns and reduce reporting... Eliminate Impediments to E-Filing Consolidated Returns and Reduce Reporting Requirements. OMB Number: 1545... eliminate impediments to the electronic filing of Federal income tax returns (e- filing) and to reduce the...

  5. Issues involved in a knowledge-based approach to procedure synthesis

    International Nuclear Information System (INIS)

    Hajek, B.K.; Khartabil, L.F.; Miller, D.W.

    1992-01-01

    Many knowledge-based systems (KBSs) have been built to assist human operators in managing nuclear power plant operating functions, such as monitoring, fault diagnosis, alarm filtering, and procedure management. For procedure management, KBSs have been built to display and track existing written procedures or to dynamically follow procedure execution by monitoring plant data and action execution and suggesting recovery steps. More recent works build KBSs able to synthesize procedures. This paper addresses and examines the main issues related to the implementation of on-line procedure synthesis using KBSs. A KBS for procedure synthesis can provide a more robust and effective procedural plan during accidents. Currently existing procedures for abnormal plant conditions, written as precompiled step sets based on the event and symptom approaches, are inherently not robust because anticipation of all potential plant states and associated plant responses is not possible. Thus, their failure recovery capability is limited to the precompiled set. Procedure synthesis has the potential to overcome these two problems because it does not require such precompilation of large sets of plant states and associated recovery procedures. Other benefits obtained from a complete procedure synthesis system are providing (a) a methodology for off-line procedure verification and (b) a methodology for the eventual automation of plant operations

  6. Martius procedure revisited for urethrovaginal fistula

    Directory of Open Access Journals (Sweden)

    N P Rangnekar

    2000-01-01

    Full Text Available Background: Urethrovaginal fistula is a dreadful com-plication of obstetric trauma due to prolonged labour or obstetric intervention commonly seen in developing coun-tries. Due to prolonged ischaemic changes, the fistula is resistant to healing. The strategic location of the fistula leads to postoperative impairment of continence mecha-nism. Anatomical repair was previously the commonest mode of surgical management, but was associated with a miserable cumulative cure rate ranging from 16-60%. Hence we tried to study the efficacy of Martius procedure in the management of urethrovaginal fistula. Material and Methods: We studied the outcome of 12 urethrovaginal fistulae, all caused by obstetric trauma, treated surgically with Martius procedure in 8 and with anatomical repair in 4, retrospectively. 9 patients had re-current fistulae while I patient had multiple fistulae. Pa-tients were followed up for the period ranging from 6 months to 4′/2 years for fistula healing, continence and postoperative complications like dvspareunia. Results: Cumulative cure rate ofMartius procedure was 87.5% with no postoperative stress incontinence, while fistula healing rate of anatomical repair was only 25% (I patient out of 4 which was also complicated by Intrin-sic Sphincter Deficiency (ISD. In case of recurrent fistu-lae the success rate of anatomical repair was 0% compared to 83.33% with Martius procedure. Conclusions: Martius procedure has shown much bet-ter overall cure rate compared to anatomical repair be-cause - a it provides better reinforcement to urethral suture line, b it provides better blood supply and lymph drainage to the ischaemic fistulous area, c provides sur-face for epithelialization and, d helps to maintain conti-nence. Hence we recommend Martius procedure as a surgical modality for the treatment of urethrovaginal fis-tula.

  7. 21 CFR 60.44 - Hearing procedures.

    Science.gov (United States)

    2010-04-01

    ... RESTORATION Due Diligence Hearings § 60.44 Hearing procedures. The due diligence hearing shall be conducted in accordance with this part, supplemented by the nonconflicting procedures in part 16. During the due diligence... requesting a hearing under part 16. The standard of due diligence set forth in § 60.36 will apply in the due...

  8. 10 CFR 72.150 - Instructions, procedures, and drawings.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Instructions, procedures, and drawings. 72.150 Section 72... WASTE Quality Assurance § 72.150 Instructions, procedures, and drawings. The licensee, applicant for a... documented instructions, procedures, or drawings of a type appropriate to the circumstances and shall require...

  9. Short communication Effects of drying procedures on chemical ...

    African Journals Online (AJOL)

    jancik.filip

    2016-12-31

    Dec 31, 2016 ... Another drying procedure included pre-treatment by heating in a ... freeze-drying method and that this procedure is useful for forage analyses and evaluation. ... oven drying (OD) and innovative drying procedures (pre-treatments .... This was probably caused by losses of compounds such as ammonia and.

  10. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  11. Quantification procedures in micro X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit

    2003-01-01

    For the quantification in micro X-ray fluorescence analysis standardfree quantification procedures have become especially important. An introduction to the basic concepts of these quantification procedures is given, followed by a short survey of the procedures which are available now and what kind of experimental situations and analytical problems are addressed. The last point is extended by the description of an own development for the fundamental parameter method, which renders the inclusion of nonparallel beam geometries possible. Finally, open problems for the quantification procedures are discussed

  12. New procedure for departure formalities

    CERN Multimedia

    HR & GS Departments

    2011-01-01

    As part of the process of simplifying procedures and rationalising administrative processes, the HR and GS Departments have introduced new personalised departure formalities on EDH. These new formalities have applied to students leaving CERN since last year and from 17 October 2011 this procedure will be extended to the following categories of CERN personnel: Staff members, Fellows and Associates. It is planned to extend this electronic procedure to the users in due course. What purpose do departure formalities serve? The departure formalities are designed to ensure that members of the personnel contact all the relevant services in order to return any necessary items (equipment, cards, keys, dosimeter, electronic equipment, books, etc.) and are aware of all the benefits to which they are entitled on termination of their contract. The new departure formalities on EDH have the advantage of tailoring the list of services that each member of the personnel must visit to suit his individual contractual and p...

  13. Procedure and apparatus for back projection

    International Nuclear Information System (INIS)

    1977-01-01

    (1) The procedure is for back projection in the form of a tomographic picture of a member, characterised in that the strip pictures are written onto the signal plate by a conversion pick-up unit; and that to the address inputs of the pick-up unit voltages are applied that represent a rotating coordinate system. (2) Procedure following claim 1 characterised by the fact that the voltages are respectively applied as sawtooth waveform horizontal and vertical television deflections. (3) Procedure following claims 1 and 2, characterised that in order to correct the television deflection voltages for the effect of a fan shaped radiation beam, first one and then the other of the amplitudes is modulated. (G.C.)

  14. A Computerized Procedure linked to Virtual Equipment

    International Nuclear Information System (INIS)

    Jung, Yeon Sub; Song, Tae Young

    2011-01-01

    Digital, information, and communication technologies have change human's behavior. This is because human has limitation to memorize and process information. Human has to access other information and real time information for important decisions. Those technologies are playing important roles. Nuclear power plants cannot be exception. Many accidents in nuclear power plants result from absent or incorrect information. The information for nuclear personnel is context sensitive. They don't have enough time to verify the context sensitive information. Therefore they skip the information, as resulting in incident. Nuclear personnel are usually carrying static paper procedures during local task performance. The procedure guides them steps to follow. There is, however, no dynamic and context sensitive information in the paper. The effect of the work is evaluated once while getting permission of the work. Afterward they are not informed. The static paper is generally simplified, so that it does not show detail of equipment being manipulated. Particularly novice workers feel difficult to understand the procedure due to lack of detail. Pictures of equipment inserted in the procedure are not enough for comprehension. A computerized procedure linked with virtual equipment is one of the best solutions to increase the detail of procedure. Virtual equipment, however, has still limitation not to provide real time information, because the virtual equipment is not synchronized with real plants

  15. Laparoscopic Whipple procedure: review of the literature.

    Science.gov (United States)

    Gagner, Michel; Palermo, Mariano

    2009-01-01

    Laparoscopic pancreatic surgery represents one of the most advanced applications for laparoscopic surgery currently in use. In the past, minimally invasive techniques were only used for diagnostic laparoscopy, staging of pancreatic cancer, and palliative procedures for unresectable pancreatic cancer. With new advances in technology and instrumentation, some sophisticated procedures are currently available, such as the Whipple procedure, one of the most sophisticated applications of minimally invasive surgery. A review of the literature shows that 146 laparoscopic Whipple procedures have been published worldwide since 1994. The authors analyzed blood loss, mean operating time, hospital stay, conversion rate, mean age, mortality rate, lymph nodes in the pathologic findings, follow up, and complications. Mean age was 59.1 years; mean operating time was 439 min. The average blood loss for the reviewed literature was 143 mL; median hospital stay was 18 days; conversion rate was 46%; number of lymph nodes in the pathologic findings was 19; and mortalities related to the procedure was low, 2 patients (1.3%) and the complication rate was 16% (23/46 patients). Complications included 2 hemorrhages, 4 bowel obstructions, 1 stress ulcer, 1 delay of gastric emptying, 4 pneumonias, and 11 leaks. This review demonstrates that the laparoscopic Whipple procedure is not only feasible but also safe, with low mortality and acceptable rates of complications.

  16. Assisted Medical Procedures (AMP)

    Data.gov (United States)

    National Aeronautics and Space Administration — DOCUMENTATION, DEVELOPMENT, AND PROGRESS The AMP was initially being developed as part the Advanced Integrated Clinical System (AICS)-Guided Medical Procedure System...

  17. 28 CFR 104.31 - Procedure for claims evaluation.

    Science.gov (United States)

    2010-07-01

    ... COMPENSATION FUND OF 2001 Claim Intake, Assistance, and Review Procedures § 104.31 Procedure for claims..., described herein as “Track A” and “Track B,” selected by the claimant on the Personal Injury Compensation Form or Death Compensation Form. (1) Procedure for Track A. The Claims Evaluator shall determine...

  18. 22 CFR 309.17 - Procedures for salary offset.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Procedures for salary offset. 309.17 Section 309.17 Foreign Relations PEACE CORPS DEBT COLLECTION Salary Offset § 309.17 Procedures for salary offset. Unless otherwise provided by statute or contract, the following procedures apply to salary offset: (a...

  19. 77 FR 30241 - Representation Procedures and Rulemaking Authority

    Science.gov (United States)

    2012-05-22

    ... the informal rulemaking procedures in the Administrative Procedure Act (APA), 5 U.S.C. 553, and... stricter requirements in sections 556 and 557 of the APA, this hearing will comply with those informal rulemaking procedures under the APA. See, e.g. United States v. Allegheny-Ludlum Steel Corp., 406 US 742...

  20. Abdominoplasty: Risk Factors, Complication Rates, and Safety of Combined Procedures.

    Science.gov (United States)

    Winocour, Julian; Gupta, Varun; Ramirez, J Roberto; Shack, R Bruce; Grotting, James C; Higdon, K Kye

    2015-11-01

    Among aesthetic surgery procedures, abdominoplasty is associated with a higher complication rate, but previous studies are limited by small sample sizes or single-institution experience. A cohort of patients who underwent abdominoplasty between 2008 and 2013 was identified from the CosmetAssure database. Major complications were recorded. Univariate and multivariate analysis was performed evaluating risk factors, including age, smoking, body mass index, sex, diabetes, type of surgical facility, and combined procedures. The authors identified 25,478 abdominoplasties from 183,914 procedures in the database. Of these, 8,975 patients had abdominoplasty alone and 16,503 underwent additional procedures. The number of complications recorded was 1,012 (4.0 percent overall rate versus 1.4 percent in other aesthetic surgery procedures). Of these, 31.5 percent were hematomas, 27.2 percent were infections and 20.2 percent were suspected or confirmed venous thromboembolism. On multivariate analysis, significant risk factors (p procedures (1.5), and procedure performance in a hospital or surgical center versus office-based surgical suite (1.6). Combined procedures increased the risk of complication (abdominoplasty alone, 3.1 percent; with liposuction, 3.8 percent; breast procedure, 4.3 percent; liposuction and breast procedure, 4.6 percent; body-contouring procedure, 6.8 percent; liposuction and body-contouring procedure, 10.4 percent). Abdominoplasty is associated with a higher complication rate compared with other aesthetic procedures. Combined procedures can significantly increase complication rates and should be considered carefully in higher risk patients. Risk, II.

  1. Tank Farm Operations Surveillance Automation Analysis

    International Nuclear Information System (INIS)

    MARQUEZ, D.L.

    2000-01-01

    The Nuclear Operations Project Services identified the need to improve manual tank farm surveillance data collection, review, distribution and storage practices often referred to as Operator Rounds. This document provides the analysis in terms of feasibility to improve the manual data collection methods by using handheld computer units, barcode technology, a database for storage and acquisitions, associated software, and operational procedures to increase the efficiency of Operator Rounds associated with surveillance activities

  2. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  3. Soil Sampling Operating Procedure

    Science.gov (United States)

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  4. Radiation exposure of operator during various interventional procedures

    International Nuclear Information System (INIS)

    Yu, In Kyu; Chung, Jin Wook; Han, Joon Koo; Park, Jae Hyung; Kang, Wee Saing

    1994-01-01

    To investigate the levels of radiation exposure of an operator which may be influenced by the wearing an apron, type of procedure, duration of fluoroscopy and operator's skill during various interventional procedures. Radiation doses were measured both inside and outside the apron(0.5 mm lead equivalent) of the operator by a film badge monitoring method and the duration of fluoroscopy was measured in 96 procedures prospectively. The procedures were 30 transcatheter arterial embolization (TAE), 25 percutaneous transhepatic biliary drainages (PTBD), 16 stone removals (SR), 15 percutaneous needle aspirations (PNCA) and 10 percutaneous nephrostomies(PCN). To assess the difference of exposure by the operator's skill, the procedures of TAE and PTBD were done separately by groups of staffs and residents. Average protective effect of the apron was 72.8%. Average radiation exposure(unit: μ Sv/procedure was 23.3 in PTBD by residents, 10.0 in PTBD by staffs, 10.0 in SR, 8.7 in TAE by residents, 7.3 in TAE by staffs, 9.0 in PCN and 6.0 in PCNA. Average radiation exposure of residents were 1.9 times greater than those of staffs. Radiation exposure was not proportionally related to the duration of fluoroscopy, but influenced by wearing an apron, various types of procedure and operator's skills

  5. Groin hematoma after electrophysiological procedures-incidence and predisposing factors.

    Science.gov (United States)

    Dalsgaard, Anja Borgen; Jakobsen, Christina Spåbæk; Riahi, Sam; Hjortshøj, Søren

    2014-10-01

    We evaluated the incidence and predisposing factors of groin hematomas after electrophysiological (EP) procedures. Prospective, observational study, enrolling consecutive patients after EP procedures (Atrial fibrillation: n = 151; Supraventricular tachycardia/Diagnostic EP: n = 82; Ventricular tachycardia: n = 18). Patients underwent manual compression for 10 min and 3 h post procedural bed rest. AF ablations were performed with INR 2-3, ACT > 300, and no protamine sulfate. Adhesive pressure dressings (APDs) were used if sheath size ≥ 10F; procedural time > 120 min; and BMI > 30. Patient-reported hematomas were recorded by a telephone follow-up after 2 weeks. Hematoma developed immediately in 26 patients (10%) and after 14 days significant hematoma was reported in 68 patients (27%). Regression analysis on sex, age, BMI 25, ACT 300, use of APD, sheath size and number, and complicated venous access was not associated with hematoma, either immediately after the procedure or after 14 days. Any hematoma presenting immediately after procedures was associated with patient-reported hematomas after 14 days, odds ratio 18.7 (CI 95%: 5.00-69.8; P hematoma immediately after EP procedures was the sole predictor of patient-reported hematoma after 2 weeks. Initiatives to prevent groin hematoma should focus on the procedure itself as well as post-procedural care.

  6. The plant operating procedure information modeling system for creation and maintenance of procedures

    International Nuclear Information System (INIS)

    Fanto, S.V.; Petras, D.S.; Reiner, R.T.; Frost, D.R.; Orendi, R.G.

    1990-01-01

    This paper reports that as a result of the accident at Three Mile Island, regulatory requirements were issued to upgrade Emergency Operating Procedures for nuclear power plants. The use of human-factored, function-oriented, EOPs were mandated to improve human reliability and to mitigate the consequences of a broad range of initiating events, subsequent failures and operator errors, without having to first diagnose the specific events. The Westinghouse Owners Group responded by developing the Emergency Response Guidelines in a human-factored, two-column format to aid in the transfer of the improved technical information to the operator during transients and accidents. The ERGs are a network of 43 interrelated guidelines which specify operator actions to be taken during plant emergencies to restore the plant to a safe and stable condition. Each utility then translates these guidelines into plant specific EOPs. The creation and maintenance of this large web of interconnecting ERGs/EOPs is an extremely complex task. This paper reports that in order to aid procedure documentation specialists with this time-consuming and tedious task, the Plant Operating Procedure Information Modeling system was developed to provide a controlled and consistent means to build and maintain the ERGs/EOPs and their supporting documentation

  7. Differentiation of ileostomy from colostomy procedures: assessing the accuracy of current procedural terminology codes and the utility of natural language processing.

    Science.gov (United States)

    Vo, Elaine; Davila, Jessica A; Hou, Jason; Hodge, Krystle; Li, Linda T; Suliburk, James W; Kao, Lillian S; Berger, David H; Liang, Mike K

    2013-08-01

    Large databases provide a wealth of information for researchers, but identifying patient cohorts often relies on the use of current procedural terminology (CPT) codes. In particular, studies of stoma surgery have been limited by the accuracy of CPT codes in identifying and differentiating ileostomy procedures from colostomy procedures. It is important to make this distinction because the prevalence of complications associated with stoma formation and reversal differ dramatically between types of stoma. Natural language processing (NLP) is a process that allows text-based searching. The Automated Retrieval Console is an NLP-based software that allows investigators to design and perform NLP-assisted document classification. In this study, we evaluated the role of CPT codes and NLP in differentiating ileostomy from colostomy procedures. Using CPT codes, we conducted a retrospective study that identified all patients undergoing a stoma-related procedure at a single institution between January 2005 and December 2011. All operative reports during this time were reviewed manually to abstract the following variables: formation or reversal and ileostomy or colostomy. Sensitivity and specificity for validation of the CPT codes against the mastery surgery schedule were calculated. Operative reports were evaluated by use of NLP to differentiate ileostomy- from colostomy-related procedures. Sensitivity and specificity for identifying patients with ileostomy or colostomy procedures were calculated for CPT codes and NLP for the entire cohort. CPT codes performed well in identifying stoma procedures (sensitivity 87.4%, specificity 97.5%). A total of 664 stoma procedures were identified by CPT codes between 2005 and 2011. The CPT codes were adequate in identifying stoma formation (sensitivity 97.7%, specificity 72.4%) and stoma reversal (sensitivity 74.1%, specificity 98.7%), but they were inadequate in identifying ileostomy (sensitivity 35.0%, specificity 88.1%) and colostomy (75

  8. 40 CFR Appendix C to Part 61 - Quality Assurance Procedures

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Quality Assurance Procedures C Appendix...—Quality Assurance Procedures Procedure 1—Determination of Adequate Chromatographic Peak Resolution In this....” Procedure 2—Procedure for Field Auditing GC Analysis Responsibilities of audit supervisor and analyst at the...

  9. 7 CFR 983.152 - Failed lots/rework procedure.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Failed lots/rework procedure. 983.152 Section 983.152..., ARIZONA, AND NEW MEXICO Rules and Regulations § 983.152 Failed lots/rework procedure. (a) Inshell rework procedure for aflatoxin. If inshell rework is selected as a remedy to meet the aflatoxin regulations of this...

  10. Model checking as an aid to procedure design

    International Nuclear Information System (INIS)

    Zhang, Wenhu

    2001-01-01

    The OECD Halden Reactor Project has been actively working on computer assisted operating procedures for many years. The objective of the research has been to provide computerised assistance for procedure design, verification and validation, implementation and maintenance. For the verification purpose, the application of formal methods has been considered in several reports. The recent formal verification activity conducted at the Halden Project is based on using model checking to the verification of procedures. This report presents verification approaches based on different model checking techniques and tools for the formalization and verification of operating procedures. Possible problems and relative merits of the different approaches are discussed. A case study of one of the approaches is presented to show the practical application of formal verification. Application of formal verification in the traditional procedure design process can reduce the human resources involved in reviews and simulations, and hence reduce the cost of verification and validation. A discussion of the integration of the formal verification with the traditional procedure design process is given at the end of this report. (Author)

  11. Is the frozen elephant trunk procedure superior to the conventional elephant trunk procedure for completion of the second stage?

    Science.gov (United States)

    Rustum, Saad; Beckmann, Erik; Wilhelmi, Mathias; Krueger, Heike; Kaufeld, Tim; Umminger, Julia; Haverich, Axel; Martens, Andreas; Shrestha, Malakh

    2017-10-01

    Our goal was to compare the results and outcomes of second-stage completion in patients who had previously undergone the elephant trunk (ET) or the frozen elephant trunk (FET) procedure for the treatment of complex aortic arch and descending aortic disease. Between August 2001 and December 2014, 53 patients [mean age 61 ± 13 years, 64% (n = 34) male] underwent a second-stage completion procedure. Of these patients, 32% (n = 17) had a previous ET procedure and 68% (n = 36) a previous FET procedure as a first-stage procedure. The median times to the second-stage procedure were 7 (0-78) months in the ET group and 8 (0-66) months in the FET group. The second-stage procedure included thoracic endovascular aortic repair in 53% (n = 28) of patients and open surgical repair in 47% (n = 25). More endovascular interventions were performed in FET patients (61%, n = 22) than in the ET group (35%, n = 6, P = 0.117). The in-hospital mortality rate was significantly lower in the FET (8%, n = 3) group compared with the ET group (29%, n = 5, P = 0.045). The median follow-up time after the second-stage operation for the entire cohort was 4.6 (0.4-10.4) years. The 5-year survival rate was 76% in the ET patients versus 89% in the FET patients (log-rank: P = 0.11). We observed a significantly lower in-hospital mortality rate in the FET group compared to the ET group. This result might be explained by the higher rate of endovascular completion in the FET group. We assume that the FET procedure offers the benefit of a more ideal landing zone, thus facilitating endovascular completion. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Randomized trial to examine procedure-to-procedure transfer in laparoscopic simulator training

    DEFF Research Database (Denmark)

    Bjerrum, F; Sorensen, J L; Konge, L

    2016-01-01

    -centre educational superiority trial. Surgical novices practised basic skills on a laparoscopic virtual reality simulator. On reaching proficiency, participants were randomized to proficiency-based training. The intervention group practised two procedures on the simulator (appendicectomy followed by salpingectomy...

  13. Modified Distal Urethral Polypropylene Sling (Canal Transobturator Tape Procedure: Efficacy for Persistent Stress Urinary Incontinence After a Conventional Midurethral Sling Procedure

    Directory of Open Access Journals (Sweden)

    Chang Hee Kim

    2013-03-01

    Full Text Available Purpose: Despite reports of persistent stress urinary incontinence (SUI in patients after the midurethral sling (MUS procedure, there is no widely accepted definition or cause of the condition. In many cases, the mesh implanted in the previous MUS procedure has been found to have migrated proximally. The aim of this study was to evaluate the efficacy of the modified distal urethral polypropylene sling, or canal transobturator tape (TOT, procedure for persistent SUI after a conventional MUS procedure on the assumption that persistent SUI after MUS is due to the location of the sling. Methods: From January 2008 to April 2012, 31 female patients who underwent the canal TOT procedure presented with incontinence or lower urinary tract symptoms (LUTS were included in this study. We identified patients who had been operated on by use of the conventional MUS procedure at other medical facilities, whose Valsalva leak pressure point was less than 120 cm-H2O by urodynamic study, and who were also diagnosed with persistent SUI. If vaginal or urethral mesh exposure was concomitant with persistent SUI, the mesh was removed completely or in part. Surgical procedures for canal TOT were identical to the original TOT procedures, except in the number and location of the vaginal incisions. Incontinence Impact Questionnaire-Short Form (IIQ-7 and Urogenital Distress Inventory-Short Form (UDI-6 scores were assessed preoperatively and at 3 months postoperatively. Results: There were no intraoperative or postoperative complications. Twenty-eight patients (90.3% showed improvement in incontinence or other LUTS. Postoperative scores of the IIQ-7 (0.65±0.48 and UDI-6 (3.48±2.28 were significantly improved compared with preoperative scores (1.26±0.58 and 7.52±4.30, respectively; P<0.05. Conclusions: Improper sling location is one of the major causes of persistent SUI after the conventional MUS procedure. Our results demonstrate that canal TOT may be an alternative

  14. Trends in Medicare Reimbursement for Orthopedic Procedures: 2000 to 2016.

    Science.gov (United States)

    Eltorai, Adam E M; Durand, Wesley M; Haglin, Jack M; Rubin, Lee E; Weiss, Arnold-Peter C; Daniels, Alan H

    2018-03-01

    Understanding trends in reimbursement is critical to the financial sustainability of orthopedic practices. Little research has examined physician fee trends over time for orthopedic procedures. This study evaluated trends in Medicare reimbursements for orthopedic surgical procedures. The Medicare Physician Fee Schedule was examined for Current Procedural Terminology code values for the most common orthopedic and nonorthopedic procedures between 2000 and 2016. Prices were adjusted for inflation to 2016-dollar values. To assess mean growth rate for each procedure and subspecialty, compound annual growth rates were calculated. Year-to-year dollar amount changes were calculated for each procedure and subspecialty. Reimbursement trends for individual procedures and across subspecialties were compared. Between 2000 and 2016, annual reimbursements decreased for all orthopedic procedures examined except removal of orthopedic implant. The orthopedic procedures with the greatest mean annual decreases in reimbursement were shoulder arthroscopy/decompression, total knee replacement, and total hip replacement. The orthopedic procedures with the least annual reimbursement decreases were carpal tunnel release and repair of ankle fracture. Rate of Medicare procedure reimbursement change varied between subspecialties. Trauma had the smallest decrease in annual change compared with spine, sports, and hand. Annual reimbursement decreased at a significantly greater rate for adult reconstruction procedures than for any of the other subspecialties. These findings indicate that reimbursement for procedures has steadily decreased, with the most rapid decrease seen in adult reconstruction. [Orthopedics. 2018; 41(2):95-102.]. Copyright 2018, SLACK Incorporated.

  15. Transformation of Helicopter PinS Procedures for Airplanes

    Directory of Open Access Journals (Sweden)

    Jakub Kraus

    2013-09-01

    Full Text Available This article deals with the possibility to use existing helicopter Point in Space procedures with minor changes for airplanes. The basis is to find parts of PinS procedures that need to be changed, suggest these changes, and then determine whether the revised procedures could be usable and could bring the benefits for airplane operations.

  16. On the design of flight-deck procedures

    Science.gov (United States)

    Degani, Asaf; Wiener, Earl L.

    1994-01-01

    In complex human-machine systems, operations, training, and standardization depend on a elaborate set of procedures which are specified and mandated by the operational management of the organization. The intent is to provide guidance to the pilots, to ensure a logical, efficient, safe, and predictable means of carrying out the mission objectives. In this report the authors examine the issue of procedure use and design from a broad viewpoint. The authors recommend a process which we call 'The Four P's:' philosophy, policies, procedures, and practices. We believe that if an organization commits to this process, it can create a set of procedures that are more internally consistent, less confusing, better respected by the flight crews, and that will lead to greater conformity. The 'Four-P' model, and the guidelines for procedural development in appendix 1, resulted from cockpit observations, extensive interviews with airline management and pilots, interviews and discussion at one major airframe manufacturer, and an examination of accident and incident reports. Although this report is based on airline operations, we believe that the principles may be applicable to other complex, high-risk systems, such as nuclear power production, manufacturing process control, space flight, and military operations.

  17. Helicopter Flight Procedures for Community Noise Reduction

    Science.gov (United States)

    Greenwood, Eric

    2017-01-01

    A computationally efficient, semiempirical noise model suitable for maneuvering flight noise prediction is used to evaluate the community noise impact of practical variations on several helicopter flight procedures typical of normal operations. Turns, "quick-stops," approaches, climbs, and combinations of these maneuvers are assessed. Relatively small variations in flight procedures are shown to cause significant changes to Sound Exposure Levels over a wide area. Guidelines are developed for helicopter pilots intended to provide effective strategies for reducing the negative effects of helicopter noise on the community. Finally, direct optimization of flight trajectories is conducted to identify low noise optimal flight procedures and quantify the magnitude of community noise reductions that can be obtained through tailored helicopter flight procedures. Physically realizable optimal turns and approaches are identified that achieve global noise reductions of as much as 10 dBA Sound Exposure Level.

  18. The interaction of criminal procedure and outcome.

    Science.gov (United States)

    Laxminarayan, Malini; Pemberton, Antony

    2014-01-01

    Procedural quality is an important aspect of crime victims' experiences in criminal proceedings and consists of different dimensions. Two of these dimensions are procedural justice (voice) and interpersonal justice (respectful treatment). Social psychological research has suggested that both voice and respectful treatment are moderated by the impact of outcomes of justice procedures on individuals' reactions. To add to this research, we extend this assertion to the criminal justice context, examining the interaction between the assessment of procedural quality and outcome favorability with victim's trust in the legal system and self-esteem. Hierarchical regression analyses reveal that voice, respectful treatment and outcome favorability are predictive of trust in the legal system and self-esteem. Further investigation reveals that being treated with respect is only related to trust in the legal system when outcome favorability is high. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Radiochemical procedures and techniques

    International Nuclear Information System (INIS)

    Flynn, K.

    1975-04-01

    A summary is presented of the radiochemical procedures and techniques currently in use by the Chemistry Division Nuclear Chemistry Group at Argonne National Laboratory for the analysis of radioactive samples. (U.S.)

  20. Splash Safety During Dermatologic Procedures Among US Dermatology Residents.

    Science.gov (United States)

    Korta, Dorota Z; Chapman, Lance W; Lee, Patrick K; Linden, Kenneth G

    2017-07-01

    Dermatologists are at potential risk of acquiring infections from contamination of the mucous membranes by blood and body fluids. However, there are little data on splash safety during procedural dermatology. To determine dermatology resident perceptions about splash risk during dermatologic procedures and to quantify the rate of protective equipment use. An anonymous on-line survey was sent to 108 United States ACGME-approved dermatology residency programs assessing frequency of facial protection during dermatologic procedures, personal history of splash injury, and, if applicable, reasons for not always wearing facial protection. A total of 153 dermatology residents responded. Rates of facial protection varied by procedure, with the highest rates during surgery and the lowest during local anesthetic injection. Over 54% of respondents reported suffering facial splash while not wearing facial protection during a procedure. In contrast, 88.9% of respondents correctly answered that there is a small risk of acquiring infection from mucosal splash. Residency program recommendations for facial protection seem to vary by procedure. The authors' results demonstrate that although facial splash is a common injury, facial protection rates and protective recommendations vary significantly by procedure. These data support the recommendation for enhanced facial protection guidelines during procedural dermatology.

  1. W-087 Acceptance test procedure. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, A.W.

    1997-06-10

    This Acceptance Test Procedure/Operational Test Procedure (ATP/OTP) has been prepared to demonstrate that the Electrical/Instrumentation and Mechanical systems function as required by project criteria and to verify proper operation of the integrated system including the interlocks.

  2. W-087 Acceptance test procedure. Revision 1

    International Nuclear Information System (INIS)

    Joshi, A.W.

    1997-01-01

    This Acceptance Test Procedure/Operational Test Procedure (ATP/OTP) has been prepared to demonstrate that the Electrical/Instrumentation and Mechanical systems function as required by project criteria and to verify proper operation of the integrated system including the interlocks

  3. Long terms results of Draf 3 procedure

    NARCIS (Netherlands)

    Georgalas, C.; Hansen, F.; Videler, W. J. M.; Fokkens, W. J.

    2011-01-01

    To assess the effectiveness and factors associated with restenosis after Draf type III (Endoscopic Modified Lothrop) frontal sinus drainage procedure. Retrospective analysis of prospectively collected data. A hundred and twenty two consecutive patients undergoing Draf III procedure for recalcitrant

  4. TMACS Test Procedure TP011: Panalarm Interface

    International Nuclear Information System (INIS)

    Seghers, R.; Washburn, S.J.

    1994-01-01

    The TMACS Software Test Procedures translate the project's acceptance criteria into test steps. The TMACS Test Plan (WHC-SD-WM-TP-148) is fulfilled when all Test Cases are approved. This Test Procedure tests the TMACS Panalarm Interface functions

  5. Endovascular thrombectomy and post-procedural headache.

    Science.gov (United States)

    Khan, Sabrina; Amin, Faisal Mohammad; Holtmannspötter, Markus; Hansen, Klaus; Florescu, Anna Maria; Fakhril-Din, Zainab; Petersen, Julie Falkenberg; Ghanizada, Hashmat; Ayata, Cenk; Gaist, David; Ashina, Messoud

    2017-12-01

    We investigated the prevalence of post-procedural headache in patients who have undergone thrombectomy for ischemic stroke, and correlated history of migraine with risk of peri-procedural complications. A total of 314 patients underwent thrombectomy at the Danish National Hospital from January 2012 to December 2014. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire according to the International Classification of Headache Disorders 3, beta version criteria. Among 96 eligible subjects, there was a significant decrease in migraine (p = 0.022) within the first 3 months after EVT compared to 1 year before treatment, which was further evident at interview time (on average 1.6 years after EVT, p = 0.013). A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 2, TTH 9), which persisted at interview time for subjects with migraine. Out of 12 subjects with peri-procedural complications, 2 had a history of migraine with aura. Thrombectomy leads to a significant decrease in previously known migraine, and new onset of headache in a small subset of patients. A history of migraine does not appear to predispose to peri-procedural complications.

  6. Value measurement of nuclear medicine procedures

    International Nuclear Information System (INIS)

    Potchen, E.J.; Harris, G.I.; Schonbein, W.R.; Rashford, N.J.

    1977-01-01

    The difficulty in measuring the benefit component for cost/benefit analysis of diagnostic procedures in medicine is portrayed as a complex issue relating the objective of intent to a classification of types of decisions a physician must make in evaluating a patient's problem. Ultimately, it seems desirable to develop measuring instruments such as attitude measurement tools by which the relative value of alternative diagnostic procedures could be measured in terms of what they contribute to diminishing the patient's personal perception of disease. Even without this idealized objective, it is reasonable to assume that diagnostic tests which do not contain information, defined as a change in the randomness of a state of knowledge, could not be expected to ultimately benefit the patient. Thus diagnostic information should provide a rational direction for the physician to modify the course of the patient's illness. Since information can be measured as a change in randomness of a knowledge state, we can determine the information content of a specific nuclear medicine procedure when faced with an array of diagnostic problems. These measurements remain to be made for clinical nuclear medicine procedures and are currently under study

  7. Simplified Transit Procedure in Railway Transport

    Directory of Open Access Journals (Sweden)

    Željko Kokorović

    2008-11-01

    Full Text Available The current transit procedure in railway transport that iscarried out on the basis of the Customs Act [ 11 of the Republicof Croatia is applied only up to the border, i. e. the issued documentsand guarantees are valid only up to the border, and byjoining the Convention on Common transit procedure, i. e. integrationof the Republic of Croatia in the European Union, theRepublic of Croatia will also have to implement the regulationsand rules of Simplified transit procedure valid in each of thethirty member states. In international railway traffic, the transportof goods is regulated by the Convention concerning InternationalCarriage by Rail- COT IF [2 1 and usage of the CIMwaybill (Contract for International Carriage of Goods by Rail.If the goods are transported in Simplified transit procedure, theformalities regarding the transport of goods performed by railcarriers using the international waybill CIM will be significantlysimplified and accelerated. In principle there are no delays dueto customs on the borders when crossing the EU borders andborders of the Convention member states, contributing greatlyto the acceleration of the transport of goods, reduction of waitingcosts and paperwork, as well as influence on the schedulereliability.

  8. Efficiency of material accountability verification procedures: A case study

    International Nuclear Information System (INIS)

    Avenhaus, R.

    1976-01-01

    In the model agreement INFCIRC/153 the international nuclear materials safeguards system has been established such that the material accountability principle is the main safeguards tool, with containment and surveillance as complementary measures. In addition, it has been agreed that the plant operator generates all data necessary for the material balance establishment and reports them to the safeguards authority and furthermore, that these data are verified by representatives of the safeguards authority with the help of independent measurements. In this paper, the problem of the determination of the efficiency of the combined system - data verification and material balance establishment - is analysed. Here, the difficulty arises that the two statistical procedures used are not independent because part of the operator's data are used in both cases. It is the purpose of this paper to work out the procedure for calculating the systems efficiency, i.e. the overall guaranteed probability of detection for the whole system for an assumed diversion and a given false alarm rate as a function of the safeguards effort spent over a given interval of time. Simplified formulae are derived which allow for a quick determination of the whole system efficiency: it is shown that the correlation between the two parts of the total system can be neglected. Therefore, the total systems efficiency can be represented as the product of the efficiencies of the two subsystems. The method developed is applied to a concrete case of a chemical reprocessing plant for irradiated fuels on the basis of data collected earlier. (author)

  9. Study on computerized presentation of emergency procedures of a nuclear plant (step 2). The guidelines of the prototype of the computerized procedure presentation system

    International Nuclear Information System (INIS)

    Niwa, Yuji; Hollnagel, E.; Iwaki, Toshio.

    1995-01-01

    New methods of information presentation and interface design are changing the working conditions in the modern Nuclear Power Plant (NPP) control room. One area receiving considerable attention is that of Emergency Operating Procedures (EOPs), which plays an essential role in NPPs. Conventionally procedures are presented in a hard copy form. However developments in information technology have offered new opportunities for the computerization of such procedures. Consideration for the first stage of computerization should be focused upon the presentation of procedures. The specification of the computerized presentation of procedures is discussed with respect to the issues which were central to the project: navigation through procedures; formatting and presentation of procedures; and process monitoring. Issues that would be included in more advanced systems, such as help and explanation facilities features, and process linking, are also discussed. This paper deals with the specific design guidelines that were implemented for the computerization of procedure presentation. Issues of principal concern that were identified from this experience are highlighted, such as the relationship between procedure presentation and format; the registration of progress through a procedure; compensation for the limitations of computer displays versus printed documents; and the way in which the added capabilities of computerized presentation can be generally utilized in the operators' working environment. (author)

  10. TMACS test procedure TP010: Integration summary. Revision 6

    International Nuclear Information System (INIS)

    Spurling, D.G.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure verifies that Test Procedures 1, 2, 3, 5 and 9 (WHC-SD-WM-TRP-105, 106, 107, 109 and 113) of TMACS Software Release 4.1 have been successfully completed

  11. Bariatric Surgery and Endoluminal Procedures: IFSO Worldwide Survey 2014.

    Science.gov (United States)

    Angrisani, L; Santonicola, A; Iovino, P; Vitiello, A; Zundel, N; Buchwald, H; Scopinaro, N

    2017-09-01

    Several bariatric surgery worldwide surveys have been previously published to illustrate the evolution of bariatric surgery in the last decades. The aim of this survey is to report an updated overview of all bariatric procedures performed in 2014.For the first time, a special section on endoluminal techniques was added. The 2014 International Federation for the Surgery of Obesity and Metabolic Disorders (IFSO) survey form evaluating the number and the type of surgical and endoluminal bariatric procedures was emailed to all IFSO societies. Trend analyses from 2011 to 2014 were also performed. There were 56/60 (93.3%) responders. The total number of bariatric/metabolic procedures performed in 2014 consisted of 579,517 (97.6%) surgical operations and 14,725 (2.4%) endoluminal procedures. The most commonly performed procedure in the world was sleeve gastrectomy (SG) that reached 45.9%, followed by Roux-en-Y gastric bypass (RYGB) (39.6%), and adjustable gastric banding (AGB) (7.4%). The annual percentage changes from 2013 revealed the increase of SG and decrease of RYGB in all the IFSO regions (USA/Canada, Europe, and Asia/Pacific) with the exception of Latin/South America, where SG decreased and RYGB represented the most frequent procedure. There was a further increase in the total number of bariatric/metabolic procedures in 2014 and SG is currently the most frequent surgical procedure in the world. This is the first survey that describes the endoluminal procedures, but the accuracy of provided data should be hopefully improved in the next future. We encourage the creation of further national registries and their continuous updates taking into account all new bariatric procedures including the endoscopic procedures that will obtain increasing importance in the near future.

  12. Special Blood Donation Procedures

    Science.gov (United States)

    ... Blood Products Special Blood Donation Procedures Precautions and Adverse Reactions During Blood Transfusion (See Overview of Blood Transfusion .) Plateletpheresis (platelet donation) In plateletpheresis, a donor gives only platelets rather than whole blood. Whole ...

  13. Methods for testing the logical structure of plant procedure documents

    International Nuclear Information System (INIS)

    Horne, C.P.; Colley, R.; Fahley, J.M.

    1990-01-01

    This paper describes an ongoing EPRI project to investigate computer based methods to improve the development, maintenance, and verification of plant operating procedures. This project began as an evaluation of the applicability of structured software analysis methods to operating procedures. It was found that these methods offer benefits, if procedures are transformed to a structured representation to make them amenable to computer analysis. The next task was to investigate methods to transform procedures into a structured representation. The use of natural language techniques to read and compile the procedure documents appears to be viable for this purpose and supports conformity to guidelines. The final task was to consider possibilities of automated verification methods for procedures. Methods to help verify procedures were defined and information requirements specified. These methods take the structured representation of procedures as input. The software system being constructed in this project is called PASS, standing for Procedures Analysis Software System

  14. 77 FR 51943 - Procedures for Safety Investigations

    Science.gov (United States)

    2012-08-28

    ... rule, Procedures for Safety Investigations, which published July 27, 2012 in the Federal Register, 77... DEFENSE NUCLEAR FACILITIES SAFETY BOARD 10 CFR Part 1708 Procedures for Safety Investigations AGENCY: Defense Nuclear Facilities Safety Board. ACTION: Proposed rule; extension of comment period...

  15. 5 CFR 179.309 - Additional administrative procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Additional administrative procedures. 179.309 Section 179.309 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.309 Additional administrative procedures. Nothing...

  16. 77 FR 67862 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-11-14

    ...The FAA is issuing this notice to advise the public that the FAA's Air Traffic Procedures Advisory Committee (ATPAC) two year charter has been coordinated and signed by the FAA Administrator. The ATPAC charter is valid for two years and provides a venue to review air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  17. 77 FR 27835 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-05-11

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures. Class B airspace will be a major topic of discussion on the ATPAC Agenda.

  18. Magnetic fusion energy. Disaster operation procedures

    International Nuclear Information System (INIS)

    1986-06-01

    In a major disaster such as an earthquake, toxic chemical release, or fire, these Disaster Operations Procedures can be used, in combination with good judgment, to minimize the risk of injury to personnel and of property damage in our laboratory, shop, and office areas. These emergency procedures apply to all personnel working within MFE/Zone-11 area including visitors, program contract personnel, and construction contract personnel

  19. Groundwater technical procedures of the U.S. Geological Survey

    Science.gov (United States)

    Cunningham, William L.; Schalk, Charles W.

    2011-01-01

    A series of groundwater technical procedures documents (GWPDs) has been released by the U.S. Geological Survey, Water-Resources Discipline, for general use by the public. These technical procedures were written in response to the need for standardized technical procedures of many aspects of groundwater science, including site and measuring-point establishment, measurement of water levels, and measurement of well discharge. The techniques are described in the GWPDs in concise language and are accompanied by necessary figures and tables derived from cited manuals, reports, and other documents. Because a goal of this series of procedures is to remain current with the state of the science, and because procedures change over time, this report is released in an online format only. As new procedures are developed and released, they will be linked to this document.

  20. Mini-Open Latarjet Procedure for Recurrent Anterior Shoulder Instability

    Directory of Open Access Journals (Sweden)

    Numa Mercier

    2011-01-01

    Full Text Available Anterior shoulder instability is a common problem. The Latarjet procedure has been advocated as an option for the treatment of anteroinferior shoulder instability. The purpose of this paper is to explain our surgical procedure titled “Mini-open Latarjet Procedure.” We detailed patient positioning, skin incision, subscapularis approach, and coracoid fixation. Then, we reviewed the literature to evaluate the clinical outcomes of this procedure.

  1. Assessment of Competence in EVAR Procedures

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L; Bech, B

    2017-01-01

    OBJECTIVE/BACKGROUND: To develop a procedure specific global rating scale for assessment of operator competence in endovascular aortic repair (EVAR). METHODS: A Delphi approach was used to achieve expert consensus. A panel of 32 international experts (median 300 EVAR procedures, range 200...... suggested by the panel and reduced to seven pivotal assessment items that reached consensus, Cronbach's alpha = 0.82. The seven item rating scale covers key elements of competence in EVAR stent placement and deployment. Each item has well defined grades with explicit anchors at unacceptable, acceptable......, and superior performance on a 5 point Likert scale. CONCLUSION: The Delphi methodology allowed for international consensus on a new procedure specific global rating scale for assessment of competence in EVAR. The resulting scale, EndoVascular Aortic Repair Assessment of Technical Expertise (EVARATE...

  2. Eye bank procedures: donor selection criteria.

    Science.gov (United States)

    Sousa, Sidney Júlio de Faria E; Sousa, Stella Barretto de Faria E

    2018-01-01

    Eye banks use sterile procedures to manipulate the eye, antiseptic measures for ocular surface decontamination, and rigorous criteria for donor selection to minimize the possibility of disease transmission due to corneal grafting. Donor selection focuses on analysis of medical records and specific post-mortem serological tests. To guide and standardize procedures, eye bank associations and government agencies provide lists of absolute and relative contraindications for use of the tissue based on donor health history. These lists are guardians of the Hippocratic principle "primum non nocere." However, each transplantation carries risk of transmission of potentially harmful agents to the recipient. The aim of the procedures is not to eliminate risk, but limit it to a reasonable level. The balance between safety and corneal availability needs to be maintained by exercising prudence without disproportionate rigor.

  3. Multimodality imaging to guide cardiac interventional procedures

    NARCIS (Netherlands)

    Tops, Laurens Franciscus

    2010-01-01

    In recent years, a number of new cardiac interventional procedures have been introduced. Catheter ablation procedures for atrial fibrillation (AF) have been refined and are now considered a good treatment option in patients with drug-refractory AF. In cardiac pacing, cardiac resynchronization

  4. 48 CFR 2045.371 - Property accountability procedures.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Property accountability procedures. 2045.371 Section 2045.371 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION... accountability procedures. (a) The threshold for detailed reporting of capitalized equipment by contractors is...

  5. 48 CFR 810.002 - Market research procedures.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Market research procedures. 810.002 Section 810.002 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS COMPETITION AND ACQUISITION PLANNING MARKET RESEARCH 810.002 Market research procedures. Contracting officers...

  6. 40 CFR 73.13 - Procedures for submittals.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Procedures for submittals. 73.13 Section 73.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Allowance Allocations § 73.13 Procedures for submittals. (a...

  7. Assessment procedures results of training in biology

    Directory of Open Access Journals (Sweden)

    Elena A. Galkina

    2018-04-01

    Full Text Available The article describes the procedures for evaluating the results of training in biology. The mechanisms for monitoring the learning outcomes of a biology teacher are presented. Examples of algorithms for procedures for evaluating learning outcomes in biology are demonstrated.

  8. Accident Sequence Evaluation Program: Human reliability analysis procedure

    International Nuclear Information System (INIS)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs

  9. Realism of procedural task trainers in a pediatric emergency medicine procedures course

    Directory of Open Access Journals (Sweden)

    Allan Shefrin

    2015-04-01

    Conclusions: Task training models utilized in our course received variable realism ratings. When deciding what type of task trainer to use future courses should carefully consider the desired aspect of realism, and how it aligns with the procedural skill, balanced with cost considerations.

  10. Acceptance and Divergence from Engineering Design Procedures Implicating Knowledge Flow

    DEFF Research Database (Denmark)

    Jensen, Ole Kjeldal; Ahmed, Saeema

    2009-01-01

    of explicit procedures and; 3) implicit procedures supporting needs that are not catered for by the explicit procedures. In this understanding, a procedure can be any kind of method, tool or framework used to support design engineers. Furthermore, the study discusses a variety of recommended actions......When developing procedures such as tools, methods and frameworks to support the development of new products, one of the challenges is ensuring their successful implementation. This paper describes a study of the development and use of such design-procedures with primary focus on the new product...

  11. 48 CFR 1552.232-74 - Payments-simplified acquisition procedures financing.

    Science.gov (United States)

    2010-10-01

    ... acquisition procedures financing. 1552.232-74 Section 1552.232-74 Federal Acquisition Regulations System... Provisions and Clauses 1552.232-74 Payments—simplified acquisition procedures financing. As prescribed in... acquisition procedures financing. Payments—Simplified Acquisition Procedures Financing (JUN 2006) Simplified...

  12. Cognition and procedure representational requirements for predictive human performance models

    Science.gov (United States)

    Corker, K.

    1992-01-01

    Models and modeling environments for human performance are becoming significant contributors to early system design and analysis procedures. Issues of levels of automation, physical environment, informational environment, and manning requirements are being addressed by such man/machine analysis systems. The research reported here investigates the close interaction between models of human cognition and models that described procedural performance. We describe a methodology for the decomposition of aircrew procedures that supports interaction with models of cognition on the basis of procedures observed; that serves to identify cockpit/avionics information sources and crew information requirements; and that provides the structure to support methods for function allocation among crew and aiding systems. Our approach is to develop an object-oriented, modular, executable software representation of the aircrew, the aircraft, and the procedures necessary to satisfy flight-phase goals. We then encode in a time-based language, taxonomies of the conceptual, relational, and procedural constraints among the cockpit avionics and control system and the aircrew. We have designed and implemented a goals/procedures hierarchic representation sufficient to describe procedural flow in the cockpit. We then execute the procedural representation in simulation software and calculate the values of the flight instruments, aircraft state variables and crew resources using the constraints available from the relationship taxonomies. The system provides a flexible, extensible, manipulative and executable representation of aircrew and procedures that is generally applicable to crew/procedure task-analysis. The representation supports developed methods of intent inference, and is extensible to include issues of information requirements and functional allocation. We are attempting to link the procedural representation to models of cognitive functions to establish several intent inference methods

  13. TMACS test procedure TP003: Graphics. Revision 5

    International Nuclear Information System (INIS)

    Scanlan, P.K.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure addresses the graphics requirements of the TMACS. The features to be tested are the data display graphics and the graphic elements that provide for operator control and selection of displays

  14. A procedure for noise uncoupling in laser interferometry

    CERN Document Server

    Barone, F; Rosa, R D; Eleuteri, A; Milano, L; Qipiani, K

    2002-01-01

    A numerical procedure for noise recognition and uncoupling is described. The procedure is applied to a Michelson interferometer and is effective in seismic and acoustic noise uncoupling from the output signal of the interferometer. Due to the low data flow coming from the instrumentation this uncoupling can be performed in real time and it is useful as a data quality procedure for interferometer data output.

  15. TMACS test procedure TP003: Graphics. Revision 6

    International Nuclear Information System (INIS)

    Scanlan, P.K.; Washburn, S.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure addresses the graphics requirements of the TMACS. The features to be tested are the data display graphics and the graphic elements that provide for operator control and selection of displays

  16. On generalized fixed sequence procedures for controlling the FWER.

    Science.gov (United States)

    Qiu, Zhiying; Guo, Wenge; Lynch, Gavin

    2015-12-30

    Testing a sequence of pre-ordered hypotheses to decide which of these can be rejected or accepted while controlling the familywise error rate (FWER) is of importance in many scientific studies such as clinical trials. In this paper, we first introduce a generalized fixed sequence procedure whose critical values are defined by using a function of the numbers of rejections and acceptances, and which allows follow-up hypotheses to be tested even if some earlier hypotheses are not rejected. We then construct the least favorable configuration for this generalized fixed sequence procedure and present a sufficient condition for the FWER control under arbitrary dependence. Based on the condition, we develop three new generalized fixed sequence procedures controlling the FWER under arbitrary dependence. We also prove that each generalized fixed sequence procedure can be described as a specific closed testing procedure. Through simulation studies and a clinical trial example, we compare the power performance of these proposed procedures with those of the existing FWER controlling procedures. Finally, when the pairwise joint distributions of the true null p-values are known, we further improve these procedures by incorporating pairwise correlation information while maintaining the control of the FWER. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Radiation exposures to technologists from nuclear medicine imaging procedures

    International Nuclear Information System (INIS)

    Sloboda, R.S.; Schmid, M.G.; Willis, C.P.

    1986-05-01

    Radiation exposures incurred by nuclear medicine technologists during diagnostic imaging and gamma camera quality control (QC) were measured on a procedural basis over a three-month period using a portable, low-range, self-reading ion chamber. A total of more than 400 measurements were made for 15 selected procedures. From these, mean procedural exposures and standard deviations were calculated. The results show that daily flood phantom QC, at 0.58 mR, and gated cardiac studies, at 0.45 mR, were the two greatest sources of exposure. Other procedures resulted in exposures varying roughly from 0.10 to 0.20 mR. Difficult patients were responsible for a doubling of technologist exposure for many procedures. Standard deviations were large for all procedures, averaging 65% of the mean values. Comparison of technologist exposure inferred from the procedural measurements with the time coincident collective dose equivalent recorded by the TLD service of the Radiation Protection Bureau indicates that approximately half of the collective technologist exposure arose from patient handling and flood QC

  18. Transfer of Procedure in Criminal Matters in Romanian Legislation

    Directory of Open Access Journals (Sweden)

    Ion Rusu

    2009-06-01

    Full Text Available Aware of the obligations assumed in fighting crime, Romania translated in itsinternal legislation the European Convention on the transfer of procedure in criminal matters,adopted in Strasbourg on 15 May 1972, ratified through Government’s Ordinance no.77/1999.The transfer of procedure in criminal matters is one of the forms of international judicialcooperation in criminal matter and represents an act on mutual trust in the organizing activityfor crime pursuit at the international level. According to law, the procedure transfer in criminalmatter consists in performing criminal procedure or continuing the procedures initiated by thecompetent Romanian authorities for an action that represents a crime, in accordance with theRomanian law and transferring it to another state. The procedure transfer in criminal matters isaccomplished only if the conditions expressly provisioned by law are fulfilled, respecting thenon bis in idem principle.

  19. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2011-03-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  20. Interventional chest procedures in pregnancy.

    LENUS (Irish Health Repository)

    Morgan, Ross K

    2012-02-01

    Interventional pulmonology encompasses diagnostic and therapeutic bronchoscopic procedures, and pleural interventions. In the last 10 years older techniques have been refined and exciting new technologies have extended the reach and application of the instruments used. The main areas within pulmonary medicine for which these interventions have a role are malignant and nonmalignant airway disease, pleural effusion, pneumothorax, and artificial airways. There are no data from well-designed prospective trials to guide recommendations for interventional pulmonary procedures in pregnancy. The recommendations provided in this article are based on critical review of reported case series, opinion from recognized experts, and personal observations.

  1. [Interventional radiology procedures for malignancies of the liver treatment: Intraarterial procedures].

    Science.gov (United States)

    Cristina, V; Pracht, M; Lachenal, Y; Adib, S; Boubaker, A; Prior, J; Senys, A; Wagner, A D; Bize, P

    2014-05-21

    Intraarterial procedures such as chemoembolization and radioembolization aim for the palliative treatment of advanced hepatocellular carcinoma (stage BCLC B and C with tumoral portal thrombosis). The combination of hepatic intraarterial chemotherapy and systemic chemotherapy can increase the probability of curing colorectal cancer with hepatic metastases not immediately accessible to surgical treatment or percutaneous ablation.

  2. Acceptance test procedure for Project W-280

    International Nuclear Information System (INIS)

    Stites, C.G.

    1994-01-01

    This Document is the Acceptance Test Procedure for 200 Area C and SY Tank Farm Lighting Upgrade. This Acceptance Test Procedure has been prepared to demonstrate that the Tank Farm Lighting Systems function correctly as required by project criteria and as intended by design

  3. MITS Feed and Withdrawal Subsystem: operating procedures

    International Nuclear Information System (INIS)

    Brown, W.S.

    1980-01-01

    This procedure details the steps involved in establishing closed loop flows, providing UF 6 vapor to the FEED header of the Sampling Subsystem and returning it through the PRODUCT and TAILS headers via the F and W recycle valves. It is essentially a Startup Procedure

  4. 17 CFR 39.3 - Procedures for registration.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Procedures for registration. 39.3 Section 39.3 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION DERIVATIVES... procedures. An organization desiring to be registered as a derivatives clearing organization shall file...

  5. 21 CFR 606.100 - Standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ... units. (9) Procedures for investigating adverse donor and recipient reactions. (10) Storage temperatures... accurately relating the product(s) to the donor. (5) Blood collection procedure, including in-process precautions taken to measure accurately the quantity of blood removed from the donor. (6) Methods of component...

  6. Working, declarative and procedural memory in specific language impairment

    OpenAIRE

    Lum, Jarrad A.G.; Conti-Ramsden, Gina; Page, Debra; Ullman, Michael T.

    2012-01-01

    According to the Procedural Deficit Hypothesis (PDH), abnormalities of brain structures underlying procedural memory largely explain the language deficits in children with specific language impairment (SLI). These abnormalities are posited to result in core deficits of procedural memory, which in turn explain the grammar problems in the disorder. The abnormalities are also likely to lead to problems with other, non-procedural functions, such as working memory, that rely at least partly on the...

  7. Procedure-specific pain management and outcome strategies

    DEFF Research Database (Denmark)

    Joshi, Girish P; Schug, Stephan A; Kehlet, Henrik

    2014-01-01

    Optimal dynamic pain relief is a prerequisite for optimizing post-operative recovery and reducing morbidity and convalescence. Procedure-specific pain management initiative aims to overcome the limitations of conventional guidelines and provide health-care professionals with practical recommendat......, optimizing fluid therapy and optimizing post-operative nursing care with early mobilization and oral feeding are utilized....... recommendations formulated in a way that facilitates clinical decision making across all the stages of the perioperative period. The procedure-specific evidence is supplemented with data from other similar surgical procedures and clinical practices to balance benefits and risks of each analgesic technique...

  8. The development of symptoms-oriented operating procedures

    International Nuclear Information System (INIS)

    Colquhoun, R.

    1983-04-01

    Until recently the formal treatment of control room procedures for nuclear power plant upset conditions has been event-oriented. The demise of Three Mile Island, Unit 2, caused the American industry to recognize the pitfalls inherent in relying totally on event-oriented procedures, and led to the initiation of a program for the development of a symptoms-oriented approach for handling upset conditions. The U.S. program has been independently paralleled by a Canadian program. This paper describes the development of the Canadian symptoms-oriented philosophy and identifies the relevance of a generic symptoms based emergency procedure to current operating practices

  9. Computerisation of procedures. Lessons learned and future perspectives

    International Nuclear Information System (INIS)

    O'Hara, J.; Pirus, D.; Nilsen, S.; Bisio, R.; Hulsund, J.-E.; Zhang, W.

    2003-07-01

    The computerisation of the procedures has been investigated for several years. Even though guidelines for such computerisation have been proposed, there is a need to extend and revise these guidelines. In this report, we look at what has been achieved so far, both within the Halden Project as well as within other organisations related to nuclear power plants. These experiences are often related to testing of particular computerised procedure systems either in research laboratories or in nuclear utilities. These activities have accumulated a body of general knowledge on the subject, as documented in other 'lessons learned' reports of the past. This report will extend this accepted body of knowledge. Furthermore, we identify the unresolved problems that need to be further studied to make usable computerised procedures for the future. The report identifies selected qualities that should be reinforced to make computerised procedure systems better. In particular, the integration aspect is emphasised. A flexible integration with the operator tasks and the remaining interfaces of the control room is important. Unless this integration is accomplished, the computerised procedures will not be functional. Another aspect of integration is combination with other systems inclusive those systems that deal with the plant documentation, electronic or paper based. This kind of integration is important to the safe and reliable operation of the plant. Good integration with plant documentation is instrumental in creating reliable QA of the procedures that covers the whole life cycle of the procedure. (Author). 48 refs., 12 figs., 2 tabs

  10. Guidelines for procedural pain in the newborn

    Science.gov (United States)

    Lago, Paola; Garetti, Elisabetta; Merazzi, Daniele; Pieragostini, Luisa; Ancora, Gina; Pirelli, Anna; Bellieni, Carlo Valerio

    2009-01-01

    Despite accumulating evidence that procedural pain experienced by newborn infants may have acute and even long-term detrimental effects on their subsequent behaviour and neurological outcome, pain control and prevention remain controversial issues. Our aim was to develop guidelines based on evidence and clinical practice for preventing and controlling neonatal procedural pain in the light of the evidence-based recommendations contained in the SIGN classification. A panel of expert neonatologists used systematic review, data synthesis and open discussion to reach a consensus on the level of evidence supported by the literature or customs in clinical practice and to describe a global analgesic management, considering pharmacological, non-pharmacological, behavioural and environmental measures for each invasive procedure. There is strong evidence to support some analgesic measures, e.g. sucrose or breast milk for minor invasive procedures, and combinations of drugs for tracheal intubation. Many other pain control measures used during chest tube placement and removal, screening and treatment for ROP, or for postoperative pain, are still based not on evidence, but on good practice or expert opinions. Conclusion: These guidelines should help improving the health care professional's awareness of the need to adequately manage procedural pain in neonates, based on the strongest evidence currently available. PMID:19484828

  11. Guide for: environmental radiological surveillance at US Department of Energy installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Denham, D.H.; Jaquish, R.E.; Michels, D.E.; Olsen, A.R.; Waite, D.A.

    1981-07-01

    This second edition of the Guide, originally published in 1977, is presented as an interim revision and does not contain major changes in content. The original objectives and scope of the Guide have not changed. The Guide is intended to: provide recommended methods, procedures, and performance criteria to bring greater comparability to DOE environmental monitoring and reporting systems; provide DOE management, particularly the Headquarters' Operational and Environmental Safety Division (OESD) and field offices, with a broad review of accepted radiological surveillance practices for use in the evaluation of environmental surveillance programs at DOE facilities; and delineate the capabilities and limitations of the various environmental monitoring systems for radioactivity currently used at DOE sites, including technical areas where there is either an inadequate basis for procedural selection or where further development work may be warranted. The document is intended as a guide, not a manual of detailed mandatory procedure

  12. Application of computerized procedure system for AP1000

    International Nuclear Information System (INIS)

    Wen Fang

    2012-01-01

    With the tendency of digitalisation in instrumentation and control system of nuclear power plants, AP1000, as well as other advanced PWRs, is provided with the technical basis for the application of CPS (computerized procedure system). This paper makes a brief introduction on CPS construction and function. CPS, as an advanced procedure system, does not only have the function of electronic indication for operation procedures, but also have the ability to monitor plant data, process the data and then present the status of the procedure steps to the reactor operator. In addition, advantages of CPS compared with paper-based procedures and comparison with digital operating system of one M310 plus advanced nuclear power plant are described. Moreover, based on current situation, this paper offers several suggestions on CPS localization for Sanmen AP1000 nuclear power project. Besides, the last part of this paper discusses problems we might meet during the process of CPS localization. (author)

  13. Emergency procedures beyond design basis ''Feed and Bleed''

    International Nuclear Information System (INIS)

    Dominguez Bautista, M.T.; Campuzano Pena, F.

    1994-01-01

    The incorporation of Beyond-Design-Basis Emergency Procedures, also called the Emergency Manual or Severe Accident Manual, has been an important step forward in nuclear power plant safety. These procedures cover situations in which the deterministic criteria used in plant design have been contravened. In such situations new accident scenarios, unforeseen system actions or a combination of both, need to be considered. Establishing these procedures is actually the last in a sequence of activities the sequence includes definition of scenarios, study of their phenomena, analysis of optional system actions, verification of their effectiveness and finally, implementation of the procedure. The systematization of these new strategies is supported by the results of the probabilistic analyses which serve in this case to pinpoint the objectives of these strategies. This paper describes the application of this methodology in the definition of a procedure for heat sink recovery on the secondary side (feed and bleed) if this has been totally or partially lost in a beyond-design-basis event. (Author)

  14. 7 CFR 1900.55 - Adverse action procedures.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Adverse action procedures. 1900.55 Section 1900.55 Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS... REGULATIONS GENERAL Adverse Decisions and Administrative Appeals § 1900.55 Adverse action procedures. (a) If...

  15. 19 CFR 181.33 - Customs processing procedures.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Customs processing procedures. 181.33 Section 181.33 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF....33 Customs processing procedures. (a) Status determination. After receipt of a post-importation claim...

  16. Chromatographic monitoring procedures in laboratory practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaplina, E G; Belova, O I; Lasunina, N A

    1976-01-01

    The Moscow Coke and Chemical Works consist of three plants in combination, viz., the coking plant, the synthetic ammonia plant using coke-oven-gas hydrogen and the oxygen plant. The plant requirements include daily analyses not only of the coke-oven gas but also of a rich gas and an ethylene fraction. The analyses are carried out in VTI-2 apparatus. The analytical data are used to calculate the calorific values and densities of the gases. The time requirements are very considerable and the laboratory has long been engaged in developing and introducing chromatographic procedures for the major constituents of coke-oven gas, rich gas and ethylene fraction. The procedure developed for the coke-oven and rich gases uses two parallel columns, one packed with molecular sieves and the other with grade KSM silica gel. Hydrogen was determined with argon as the carrier gas, and all other constituents with helium. The procedure was time-consuming and complicated. An attempt was made to separate the gases in an LKhM-7a chromatograph with a programme-controlled 50 to 250/sup 0/C heating cycle, but the procedure still had a number of serious defects and could not be recommended for regular quality control. The final variant involved two parallel columns and a procedure based on that in GOST 14920 (''Dry gas. Proximate analysis''). The chromatograph was a type KhL-69 with a 6-way cock in the gas line so that each of the columns could be brought on stream in succession. The analytical column packings were zeolite (in a 2 m column) and diatomaceous brick with 25% n-hexadecane (in a 6 m column).

  17. COGNITIVE FATIGUE FACILITATES PROCEDURAL SEQUENCE LEARNING

    Directory of Open Access Journals (Sweden)

    Guillermo eBorragán

    2016-03-01

    Full Text Available Enhanced procedural learning has been evidenced in conditions where cognitive control is diminished, including hypnosis, disruption of prefrontal activity and non-optimal time of the day. Another condition depleting the availability of controlled resources is cognitive fatigue. We tested the hypothesis that cognitive fatigue, eventually leading to diminished cognitive control, facilitates procedural sequence learning. In a two-day experiment, twenty-three young healthy adults were administered a serial reaction time task (SRTT following the induction of high or low levels of cognitive fatigue, in a counterbalanced order. Cognitive fatigue was induced using the Time load Dual-back (TloadDback paradigm, a dual working memory task that allows tailoring cognitive load levels to the individual's optimal performance capacity. In line with our hypothesis, reaction times in the SRTT were faster in the high- than in the low-level fatigue condition, and performance improvement showed more of a benefit from the sequential components than from motor. Altogether, our results suggest a paradoxical, facilitating impact of cognitive fatigue on procedural motor sequence learning. We propose that facilitated learning in the high-level fatigue condition stems from a reduction in the cognitive resources devoted to cognitive control processes that normally oppose automatic procedural acquisition mechanisms.

  18. Postoperative infections in craniofacial reconstructive procedures.

    Science.gov (United States)

    Fialkov, J A; Holy, C; Forrest, C R; Phillips, J H; Antonyshyn, O M

    2001-07-01

    The rate of, and possible risk factors for, postoperative craniofacial infection is unclear. To investigate this problem, we reviewed 349 cases of craniofacial skeletal procedures performed from 1996 to 1999 at our institution. Infection rate was determined and correlated with the use of implants, operative site, and cause of deformity. The inclusion criteria consisted of all procedures requiring autologous or prosthetic implantation in craniofacial skeletal sites, as well as all procedures involving bone or cartilage resection, osteotomies, debridement, reduction and/or fixation. Procedures that did not involve bone or cartilage surgery were excluded. The criteria for diagnosis of infection included clinical confirmation and one or more of 1) intravenous or oral antibiotic treatment outside of the prophylactic surgical regimen; 2) surgical intervention for drainage, irrigation, and or debridement; and 3) microbiological confirmation. Among the 280 surgical cases that fit the inclusion criteria and had complete records, there were 23 cases of postoperative infection (8.2%). The most common site for postoperative infection was the mandible (infection rate = 16.7%). Multiple logistic regression analysis revealed gunshot wound to be the most significant predictor of postoperative infection. Additionally, porous polyethylene implantation through a transoral route was correlated with a significant risk of postoperative infection.

  19. Procedural Modeling for Digital Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Simon Haegler

    2009-01-01

    Full Text Available The rapid development of computer graphics and imaging provides the modern archeologist with several tools to realistically model and visualize archeological sites in 3D. This, however, creates a tension between veridical and realistic modeling. Visually compelling models may lead people to falsely believe that there exists very precise knowledge about the past appearance of a site. In order to make the underlying uncertainty visible, it has been proposed to encode this uncertainty with different levels of transparency in the rendering, or of decoloration of the textures. We argue that procedural modeling technology based on shape grammars provides an interesting alternative to such measures, as they tend to spoil the experience for the observer. Both its efficiency and compactness make procedural modeling a tool to produce multiple models, which together sample the space of possibilities. Variations between the different models express levels of uncertainty implicitly, while letting each individual model keeping its realistic appearance. The underlying, structural description makes the uncertainty explicit. Additionally, procedural modeling also yields the flexibility to incorporate changes as knowledge of an archeological site gets refined. Annotations explaining modeling decisions can be included. We demonstrate our procedural modeling implementation with several recent examples.

  20. The Accelerated Procedure for Electrical Work (TPA)

    CERN Document Server

    Coelingh, G J

    2000-01-01

    The accelerated procedure for electrical work [in French: Travaux électriques selon Procédure Accélérée (TPA)] was introduced in October 1996. It allows the contractor to carry out minor electrical installation jobs (about 350 a year) independently. The special features of the TPA are that the number of hours to be worked is limited to 16 and the cost to less than 1000 CHF. This procedure has substantial advantages for both the requesters and ST division. Firstly, the requester benefits from direct contact with the contractor, prompt action and simplified invoicing. In addition, ST division, relieved of ordinary minor work, can concentrate on larger-scale projects and can take advantage of a simplified system of administration. The author sets out the course of the procedure, its advantages and drawbacks, the statistics and the results of a satisfaction questionnaire. This procedure could be adapted and extended to other operations linked to future contracts.

  1. SQUG cable tray and conduit evaluation procedure

    International Nuclear Information System (INIS)

    Smith, P.D.; Eder, S.J.; Conoscente, J.P.

    1990-01-01

    Cable tray and conduit systems for electrical cables are a common feature and industrial facilities. They have an excellent performance history in past strong earthquake, even though they are rarely designed for earthquakes. Considerable data have been gathered on their performance in earthquakes and in shake table testing. The data have been used to develop a procedure for the verification of the seismic adequacy of cable tray and conduit systems in operating nuclear plants. The procedure is discussed in this paper. It will result in substantial savings, such as reduced engineering effort, fewer modifications of existing hardware, and simpler documentation, relative to alternate procedures like dynamic analysis of shake table testing. The procedure ensures safety-function in a unique manner since the methodology used to develop it (1) is based on a large body of historical data and (2) uses a relative approach of ensuring that nuclear plant systems will perform at least as well as systems that performed well in past earthquakes. (orig.)

  2. A procedure for effective Dancoff factor calculation

    International Nuclear Information System (INIS)

    Milosevic, M.

    2001-01-01

    In this paper, a procedure for Dancoff factors calculation based on equivalence principle and its application in the SCALE-4.3 code system is described. This procedure is founded on principle of conservation of neutron absorption for resolved resonance range in a heterogeneous medium and an equivalent medium consisted of an infinite array of two-region pin cells, where the presence of other fuel rods is taken into account through a Dancoff factor. The neutron absorption in both media is obtained using a fine-group elastic slowing-down calculation. This procedure is implemented in a design oriented lattice physics code, which is applicable for any geometry where the method of collision probability is possible to apply to get a flux solution. Proposed procedure was benchmarked for recent exercise that represents a system with a fuel double heterogeneity, i.e., fuel in solid form (pellets) surrounded by fissile material in solution, and for a 5x5 irregular pressurised water reactor assembly, which requires different Dancoff factors. (author)

  3. 22 CFR 201.23 - Procurement under private sector procedures.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Procurement under private sector procedures... § 201.23 Procurement under private sector procedures. (a) General requirements. Procurements under private sector procedures will normally be carried out by importers using negotiated procurement...

  4. On the additive splitting procedures and their computer realization

    DEFF Research Database (Denmark)

    Farago, I.; Thomsen, Per Grove; Zlatev, Z.

    2008-01-01

    Two additive splitting procedures are defined and studied in this paper. It is shown that these splitting procedures have good stability properties. Some other splitting procedures, which are traditionally used in mathematical models used in many scientific and engineering fields, are sketched. All...

  5. TMACS Test Procedure TP008: SACS Interface. Revision 5

    International Nuclear Information System (INIS)

    Washburn, S.J.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS SACS Interface functions

  6. Peer-assisted learning model enhances clinical clerk's procedural skills.

    Science.gov (United States)

    Huang, Chia-Chang; Hsu, Hui-Chi; Yang, Ling-Yu; Chen, Chen-Huan; Yang, Ying-Ying; Chang, Ching-Chih; Chuang, Chiao-Lin; Lee, Wei-Shin; Lee, Fa-Yauh; Hwang, Shinn-Jang

    2018-05-17

    Failure to transfer procedural skills learned in a laboratory to the bedside is commonly due to a lack of peer support/stimulation. A digital platform (Facebook) allows new clinical clerks to share experiences and tips that help augment their procedural skills in a peer-assisted learning/teaching method. This study aims to investigate the effectiveness of the innovation of using the digital platform to support the transfer of laboratory-trained procedural skills in the clinical units. Volunteer clinical clerks (n = 44) were enrolled into the peer-assisted learning (PAL) group, which was characterized by the peer-assisted learning of procedural skills during their final 3-month clinical clerkship block. Other clerks (n = 51) did not join the procedural skills-specific Facebook group and served as the self-directed learning regular group. The participants in both the PAL and regular groups completed pre- and post-intervention self-assessments for general self-assessed efficiency ratings (GSER) and skills specific self-assessed efficiency ratings (SSSER) for performing vein puncture, intravenous (IV) catheter and nasogastric (NG) tube insertion. Finally, all clerks received the post-intervention 3-station Objective Structured Clinical Skills Examination (OSCE) to test their proficiency for the abovementioned three procedural skills. Higher cumulative numbers of vein punctures, IV catheter insertions and NG tube insertions at the bedside were carried out by the PAL group than the regular group. A greater improvement in GSERs and SSSERs for medical procedures was found in the PAL group than in the regular group. The PAL group obtained higher procedural skills scores in the post-intervention OSCEs than the regular group. Our study suggested that the implementation of a procedural skill-specific digital platform effectively helps clerks to transfer laboratory-trained procedural skills into the clinical units. In comparison with the regular self-directed learning

  7. Development of symptoms-oriented operating procedures

    International Nuclear Information System (INIS)

    Colquhoun, R.

    1984-01-01

    Until recently, the formal treatment of control room procedures for upset conditions in nuclear power plants has been event-oriented. This orientation was not so much a reflection of power plant operating practice as it was a reflection of design-oriented thinking - design-basis events, therefore event-oriented procedures. Event orientation is not common in other professions. In the medical profession, for example, the stabilization of vital functions through a symptoms-oriented approach has priority over diagnosis and prognosis. The American nuclear power industry has initiated programs for the development and application of a symptoms-oriented approach for handling upset conditions. Canadian programs have independently paralleled the US programs. This article describes the rationale and current applications of the Canadian programs and identifies the relevance of a generic symptoms-based emergency procedure to current operating practices

  8. A procedure for building product models

    DEFF Research Database (Denmark)

    Hvam, Lars; Riis, Jesper; Malis, Martin

    2001-01-01

    This article presents a procedure for building product models to support the specification processes dealing with sales, design of product variants and production preparation. The procedure includes, as the first phase, an analysis and redesign of the business processes, which are to be supported...... with product models. The next phase includes an analysis of the product assortment, and the set up of a so-called product master. Finally the product model is designed and implemented using object oriented modelling. The procedure is developed in order to ensure that the product models constructed are fit...... for the business processes they support, and properly structured and documented, in order to facilitate that the systems can be maintained continually and further developed. The research has been carried out at the Centre for Industrialisation of Engineering, Department of Manufacturing Engineering, Technical...

  9. Fingertip replantation using the subdermal pocket procedure.

    Science.gov (United States)

    Lin, Tsan-Shiun; Jeng, Seng-Feng; Chiang, Yuan-Cheng

    2004-01-01

    Restoration of finger length and function are the goals of replantation after fingertip amputation. Methods include microsurgical replantation and nonmicrosurgical replantation, such as composite graft techniques. To increase the survival rates for composite grafts, the subcutaneous pocket procedure has been used as a salvage procedure. The subdermal pocket procedure, which is a modification of the subcutaneous pocket procedure, was used for replantation of 17 fingertips in 16 consecutive patients. Eight fingertips experienced guillotine injuries and the other nine fingertips experienced crush injuries. Revascularization of one digital artery without available venous outflow was performed for six fingers, and composite graft techniques were used for the other 11 fingers. The success rate was 16 of 17 cases. The difference in success rates for guillotine versus crush injuries was statistically significant. Comparison of patients with arterial anastomoses and patients without arterial anastomoses also indicated a statistically significant difference. Thirteen fingertips survived completely. One finger, demonstrating complete loss and early termination of the pocketing procedure, was amputated on the eighth postoperative day. Two fingers were partially lost because of severe crushing injuries. One finger demonstrated partial loss of more than one quarter of the fingertip, which required secondary revision, because the patient was a heavy smoker. The pocketing period was 8 +/- 1 days (mean +/- SD, n = 6) for the fingers revascularized with one digital arterial anastomosis and 13.3 +/- 1.9 days (n = 10) for the fingers successfully replanted with composite graft techniques. The mean active range of motion of the interphalangeal joint of the three thumbs was 65 +/- 5 degrees, and that of the distal interphalangeal joint of the other 11 fingers was 51 +/- 11 degrees. The static two-point discrimination result was 6.4 +/- 1.0 mm (n = 14) after an average of 11 +/- 5 months

  10. Virtual reality simulation training in a high-fidelity procedure suite

    DEFF Research Database (Denmark)

    Lönn, Lars; Edmond, John J; Marco, Jean

    2012-01-01

    To assess the face and content validity of a novel, full physics, full procedural, virtual reality simulation housed in a hybrid procedure suite.......To assess the face and content validity of a novel, full physics, full procedural, virtual reality simulation housed in a hybrid procedure suite....

  11. 37 CFR 204.5 - Procedures for requesting access to records.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Procedures for requesting access to records. 204.5 Section 204.5 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES PRIVACY ACT: POLICIES AND PROCEDURES § 204.5 Procedures for...

  12. Biological control and surveillance measures for hospital radiopharmacy

    International Nuclear Information System (INIS)

    Joshi, S.H.; Mehra, K.S.; Ramamoorthy, N.

    1997-01-01

    The principles and procedures for the surveillance measures and the care required to be observed in hospital radiopharmacy, though much of the aspects are quite valid for centralized and industrial radiopharmacies, are described. 1 tab

  13. Contemporary management and surveillance strategy after shunt or endoscopic third ventriculostomy procedures for hydrocephalus.

    Science.gov (United States)

    Janjua, M Burhan; Hoffman, Caitlin E; Souweidane, Mark M

    2017-11-01

    The management of hydrocephalus can be challenging even in expert hands. Due to acute presentation, recurrence, accompanying complications, the need for urgent diagnosis; a robust management plan is an absolute necessity. We devised a novel time efficient surveillance strategy during emergency, and clinic follow up settings which has never been described in the literature. We searched all articles embracing management/surveillance protocol on pediatric hydrocephalus utilizing the terms "hydrocephalus follow up" or "surveillance protocol after hydrocephalus treatment". The authors present their own strategy based on vast experience in the hydrocephalus management at a single institution. The need for the diagnostic laboratory testing, age and presentation based radiological imaging, significance of neuro-opthalmological exam, and when to consider the emergent exploration have been discussed in detail. Moreover, a definitive triaging strategy has been described with the help of flow chart diagrams for clinicians, and the neurosurgeons in practice. The triage starts from detail history, physical exam, necessary labs, radiological imaging depending on the presentation, and the age of the child. A quick head CT scan helps after shunt surgery while, a FAST sequence MRI scan (fsMRI) is important in post ETV patients. The need for neuro-opthalmological exam, and the shunt series stays vital in asymptomatic patients during regular follow up. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Accident Sequence Evaluation Program: Human reliability analysis procedure

    Energy Technology Data Exchange (ETDEWEB)

    Swain, A.D.

    1987-02-01

    This document presents a shortened version of the procedure, models, and data for human reliability analysis (HRA) which are presented in the Handbook of Human Reliability Analysis With emphasis on Nuclear Power Plant Applications (NUREG/CR-1278, August 1983). This shortened version was prepared and tried out as part of the Accident Sequence Evaluation Program (ASEP) funded by the US Nuclear Regulatory Commission and managed by Sandia National Laboratories. The intent of this new HRA procedure, called the ''ASEP HRA Procedure,'' is to enable systems analysts, with minimal support from experts in human reliability analysis, to make estimates of human error probabilities and other human performance characteristics which are sufficiently accurate for many probabilistic risk assessments. The ASEP HRA Procedure consists of a Pre-Accident Screening HRA, a Pre-Accident Nominal HRA, a Post-Accident Screening HRA, and a Post-Accident Nominal HRA. The procedure in this document includes changes made after tryout and evaluation of the procedure in four nuclear power plants by four different systems analysts and related personnel, including human reliability specialists. The changes consist of some additional explanatory material (including examples), and more detailed definitions of some of the terms. 42 refs.

  15. Procedural lawmaking at the International Criminal Tribunals

    NARCIS (Netherlands)

    Sluiter, G.; Darcy, S.; Powderly, J.

    2011-01-01

    This chapter examines the role played by the judges in creating the procedural rules which govern the functioning of the ad hoc Tribunals. Noting that the bench had been tasked with devising its own rules of procedure and evidence, it queries whether judicial lawmaking in this context at the

  16. 32 CFR 644.85 - General negotiation procedures.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true General negotiation procedures. 644.85 Section... negotiation procedures. (a) Provisions of Military Construction Appropriation Act. (1) Section 108 of the... of Pub. L. 91-646 and this chapter. (c) Negotiations on the basis of ownership; “Package-Deal...

  17. 16 CFR 1.95 - Procedures upon election.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Procedures upon election. 1.95 Section 1.95 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL... the appropriate district court of the United States for an order enforcing the assessment of the civil...

  18. Analysis and optimization of blood-testing procedures.

    NARCIS (Netherlands)

    Bar-Lev, S.K.; Boxma, O.J.; Perry, D.; Vastazos, L.P.

    2017-01-01

    This paper is devoted to the performance analysis and optimization of blood testing procedures. We present a queueing model of two queues in series, representing the two stages of a blood-testing procedure. Service (testing) in stage 1 is performed in batches, whereas it is done individually in

  19. An Audit of Gynaecological Procedures Performed at Aminu Kano ...

    African Journals Online (AJOL)

    Background: Audit of all gynecological procedures as one of the commonest operations performed in medical practice is not routinely done in developing countries, including Nigeria. Aim: The study was aimed at determining the rate of all gynecological procedures performed; the common gynecological procedures and ...

  20. Improvement and Validation of Weld Residual Stress Modelling Procedure

    International Nuclear Information System (INIS)

    Zang, Weilin; Gunnars, Jens; Dong, Pingsha; Hong, Jeong K.

    2009-06-01

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  1. Improvement and Validation of Weld Residual Stress Modelling Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Weilin; Gunnars, Jens (Inspecta Technology AB, Stockholm (Sweden)); Dong, Pingsha; Hong, Jeong K. (Center for Welded Structures Research, Battelle, Columbus, OH (United States))

    2009-06-15

    The objective of this work is to identify and evaluate improvements for the residual stress modelling procedure currently used in Sweden. There is a growing demand to eliminate any unnecessary conservatism involved in residual stress assumptions. The study was focused on the development and validation of an improved weld residual stress modelling procedure, by taking advantage of the recent advances in residual stress modelling and stress measurement techniques. The major changes applied in the new weld residual stress modelling procedure are: - Improved procedure for heat source calibration based on use of analytical solutions. - Use of an isotropic hardening model where mixed hardening data is not available. - Use of an annealing model for improved simulation of strain relaxation in re-heated material. The new modelling procedure is demonstrated to capture the main characteristics of the through thickness stress distributions by validation to experimental measurements. Three austenitic stainless steel butt-welds cases are analysed, covering a large range of pipe geometries. From the cases it is evident that there can be large differences between the residual stresses predicted using the new procedure, and the earlier procedure or handbook recommendations. Previously recommended profiles could give misleading fracture assessment results. The stress profiles according to the new procedure agree well with the measured data. If data is available then a mixed hardening model should be used

  2. Robotic pancreas drainage procedure for chronic pancreatitis: robotic lateral pancreaticojejunostomy (Puestow procedure).

    Science.gov (United States)

    Khan, Adeel S; Siddiqui, Imran; Vrochides, Dionisios; Martinie, John B

    2018-01-01

    Lateral pancreaticojejunostomy (LPJ), also known as the Puestow procedure, is a complex surgical procedure reserved for patients with refractory chronic pancreatitis (CP) and a dilated pancreatic duct. Traditionally, this operation is performed through an open incision, however, recent advancements in minimally invasive techniques have made it possible to perform the surgery using laparoscopic and robotic techniques with comparable safety. Though we do not have enough data yet to prove superiority of one over the other, the robotic approach appears to have an advantage over the laparoscopic technique in better visualization through 3-dimensional (3D) imaging and availability of wristed instruments for more precise actions, which may translate into superior outcomes. This paper is a description of our technique for robotic LPJ in patients with refractory CP. Important principles of patient selection, preoperative workup, surgical technique and post-operative management are discussed. A short video with a case presentation and highlights of the important steps of the surgery is included.

  3. A “Cookbook” Cost Analysis Procedure for Medical Information Systems*

    Science.gov (United States)

    Torrance, Janice L.; Torrance, George W.; Covvey, H. Dominic

    1983-01-01

    A costing procedure for medical information systems is described. The procedure incorporates state-of-the-art costing methods in an easy to follow “cookbook” format. Application of the procedure consists of filling out a series of Mac-Tor EZ-Cost forms. The procedure and forms have been field tested by application to a cardiovascular database system. This article describes the major features of the costing procedure. The forms and other details are available upon request.

  4. Parallel between the “small reform” law procedure and the arbitration procedure. Practical influences on business environment

    Directory of Open Access Journals (Sweden)

    Cezar HÎNCU

    2011-06-01

    Full Text Available The financial blockings determined by the economical crisis in the last years bounded the business environment, through pressures on the legislature and regulations of own associative institutions (commerce chambers, to claim practical measures leading to more rapid and less expensive completion of commercial litigations. Within the period 2010-2011, these were carried out by adopting the Law 202/2010 and by the New Rules of Arbitral Procedure of International Commercial Arbitration Court of CCIR. The changes of the arbitration norms aim at the simplification of the procedure, but the essential ones – the possibility to attack with action in annulment the conclusions for arbitration adjourn or the agreement of some temporary measures leading to hastening the causes resolutions, are inapplicable, because they are not linked to rigid stipulations of the new CPC. The changes of Law 202/2010 aim at reducing the litigations resolutions (summoning procedure, term changing, causes postponing. Also, the possibility of cassation with sending to rejudgement is limited. The changes in the interest of the business environment consist of introduction the mediation, as previous procedure. The normative act specifies adjourning the prescription term during mediation, the right of the judge to fine the parties not present at mediation, after accepting it.

  5. 47 CFR 80.331 - Bridge-to-bridge communication procedure.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Bridge-to-bridge communication procedure. 80..., Alarm, Urgency and Safety Procedures § 80.331 Bridge-to-bridge communication procedure. (a) Vessels subject to the Bridge-to-Bridge Act transmitting on the designated navigational frequency must conduct...

  6. 75 FR 63255 - Air Traffic Procedures Advisory Committee Meeting

    Science.gov (United States)

    2010-10-14

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  7. Still special? Harvesting procedures for industrial hemp

    Directory of Open Access Journals (Sweden)

    Hans-Jörg Gusovius

    2016-01-01

    Full Text Available A multitude of different harvesting procedures is available after the re-approval of hemp growing in Germany about 20 years ago. Established, but as well recent machine developments enable the supply of raw materials for further processing or as food and feed materials. The necessary specialization level results in high but, compared to other established crops, not exceeding procedural costs. In this study, harvesting procedures and technologies are analyzed that are currently used under Northern European cultivation conditions. However, technological enhancements are still needed in order to improve the competitiveness of fibre hemp in the crop rotation as well as of hemp-based semi-finished and finished products.

  8. Outcome of mears procedure for Sprengel′s deformity

    Directory of Open Access Journals (Sweden)

    Atul Rajeshwar Bhasker

    2011-01-01

    Conclusion: The Mears procedure gives excellent cosmetic and functional results. This procedure addresses the functional aspect of the deformity and is much more acceptable to the patient and parents.

  9. Argon analytical procedures for potassium-argon dating

    International Nuclear Information System (INIS)

    Gabites, J.E.; Adams, C.J.

    1981-01-01

    A manual for the argon analytical methods involved in potassium-argon geochronology, including: i) operating procedures for the ultra-high vacuum argon extraction/purification equipment for the analysis of nanolitre quantities of radiogenic argon in rocks, minerals and gases; ii) operating procedures for the AEI-MS10 gas source mass spectrometer

  10. Procedural Due Process Rights in Student Discipline.

    Science.gov (United States)

    Pressman, Robert; Weinstein, Susan

    To assist administrators in understanding procedural due process rights in student discipline, this manual draws together hundreds of citations and case summaries of federal and state court decisions and provides detailed commentary as well. Chapter 1 outlines the general principles of procedural due process rights in student discipline, such as…

  11. Using a standards committee to design practical procedure system improvements

    International Nuclear Information System (INIS)

    Grider, D.A.; Plung, D.

    1993-01-01

    In the post-Three Mile Island (TMI) environment, numerous reports have been issued on how to improve the quality of procedures used at government and commercial nuclear facilities. The studies tend to be long on what is wrong with existing procedures and short on practical directions on how to fix those faults. Few of these studies have been conducted by practitioners with full-time procedure-managing or procedure writing experience. None of these studies go into detail on how to improve the procedure system itself. Over the last 10 yr, various nuclear facilities within the US Department of Energy (DOE) have carried out individual programs to develop procedures that meet post-TMI standards. However, ∼2 yr ago, DOE formed a Procedures Standards Committee to advise DOE in developing a set of post-TMI guidelines that could be consistently applied throughout all DOE nuclear facilities. The committee has achieved not only its original mission by producing a series of integrated guidance documents but has also evolved a systems approach to procedures management that sets new standards for procedure quality and efficiency. As members of this committee, the authors want to describe what has made the group's approach so successful. The lessons learned may be translatable to a wide range of government and commercial industry procedure programs

  12. Radiation dose to the operator during fluoroscopically guided spine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca; Pravata, Emanuele; Cianfoni, Alessandro [Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale di Lugano, Lugano (Switzerland); Presilla, Stefano [Unita di Fisica Medica, Ente Ospedaliero Cantonale (EOC), Bellinzona (Switzerland)

    2017-09-15

    Fluoroscopy is widely used to guide diagnostic and therapeutic spine procedures. The purpose of this study was to quantify radiation incident on the operator (operator Air Kerma) during a wide range of fluoroscopy-guided spine procedures and its correlation with the amount of radiation incident on the patient (Kerma Area Product - KAP). We retrospectively included 57 consecutive fluoroscopically guided spine procedures. KAP [Gy cm{sup 2}] and total fluoroscopy time were recorded for each procedure. An electronic dosimeter recorded the operator Air Kerma [μGy] for each procedure. Operator Air Kerma for each procedure, correlation between KAP and operator Air Kerma, and between KAP and fluoroscopy time was obtained. Operator Air Kerma was widely variable across procedures, with median value of 6.4 μGy per procedure. Median fluoroscopy time and median KAP per procedure were 2.6 min and 4.7 Gy cm{sup 2}, respectively. There was correlation between operator Air Kerma and KAP (r{sup 2} = 0.60), with a slope of 1.6 μGy Air Kerma per unit Gy cm{sup 2} KAP incident on the patient and between fluoroscopy time and KAP (r{sup 2} = 0.63). Operator Air Kerma during individual fluoroscopy-guided spine procedures can be approximated from the commonly and readily available information of the total amount of radiation incident on the patient, measured as KAP. (orig.)

  13. Safety management procedures and practices at Indira Gandhi Centre for Atomic Research

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, P.; Lee, S.M.; Kapoor, R.P.; Raghunath, V.M.; Karthikeyan, S.V. [Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)]. E-mail: kapoor@igcar.ernet.in

    2004-07-01

    The Indira Gandhi Centre for Atomic Research (IGCAR) operates FBTR (Fast Breeder Test Reactor), KAMINI (neutron source reactor), radiometallurgical laboratory, radiochemical laboratory, reprocessing plant, industrial scale sodium loops, advanced research laboratories, workshops, etc. Codified safety management procedures with systematic surveillance are essential for safe and reliable operations and these are described under the classifications of radiation safety, industrial safety and reactor operations with special emphasis on the human factor. Health physics teams, independent of the plant facility, supervise the radioactive facilities of the centre. Industrial safety standards are maintained by another independent section. Safety management for the reactors include a clear organisational structure, adequate documentation, compulsory training and licencing, safe working methods taking into account human factors and review by independent safety authorities. (author)

  14. Safety management procedures and practices at Indira Gandhi Centre for Atomic Research

    International Nuclear Information System (INIS)

    Rodriguez, P.; Lee, S.M.; Kapoor, R.P.; Raghunath, V.M.; Karthikeyan, S.V.

    2004-01-01

    The Indira Gandhi Centre for Atomic Research (IGCAR) operates FBTR (Fast Breeder Test Reactor), KAMINI (neutron source reactor), radiometallurgical laboratory, radiochemical laboratory, reprocessing plant, industrial scale sodium loops, advanced research laboratories, workshops, etc. Codified safety management procedures with systematic surveillance are essential for safe and reliable operations and these are described under the classifications of radiation safety, industrial safety and reactor operations with special emphasis on the human factor. Health physics teams, independent of the plant facility, supervise the radioactive facilities of the centre. Industrial safety standards are maintained by another independent section. Safety management for the reactors include a clear organisational structure, adequate documentation, compulsory training and licencing, safe working methods taking into account human factors and review by independent safety authorities. (author)

  15. Procedure Redesign Methods : E3-Control: a redesign methodology for control procedures

    NARCIS (Netherlands)

    Liu, J.; Hofman, W.J.; Tan, Y.H.

    2011-01-01

    This chapter highlights the core research methodology, e3-control, that is applied throughout the ITAIDE project for the purpose of control procedure redesign. We present the key concept of the e3-control methodology and its technical guidelines. Based on the output of this chapter, domain experts

  16. Scope and procedures of fuel management for PWR nuclear power plant

    International Nuclear Information System (INIS)

    Yao Zenghua

    1997-01-01

    The fuel management scope of PWR nuclear power plant includes nuclear fuel purchase and spent fuel disposal, ex-core fuel management, in-core fuel management, core management and fuel assembly behavior follow up. A suit of complete and efficient fuel management procedures have to be created to ensure the quality and efficiency of fuel management work. The hierarchy of fuel management procedure is divided into four levels: main procedure, administration procedure, implement procedure and technic procedure. A brief introduction to the fuel management scope and procedures of PWR nuclear power plant are given

  17. 10 CFR 16.15 - Procedures for internal salary offset.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Procedures for internal salary offset. 16.15 Section 16.15 Energy NUCLEAR REGULATORY COMMISSION SALARY OFFSET PROCEDURES FOR COLLECTING DEBTS OWED BY FEDERAL EMPLOYEES TO THE FEDERAL GOVERNMENT § 16.15 Procedures for internal salary offset. (a) Deductions to...

  18. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Plastic pipe: Qualifying joining procedures. 192... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  19. 7 CFR 356.1 - Property subject to forfeiture procedures.

    Science.gov (United States)

    2010-01-01

    ... procedures. This part sets forth procedures relating to the forfeiture of any plant, equipment, means of... vessels, vehicles, aircraft, and other equipment used to aid in the importation or exportation of plants... 7 Agriculture 5 2010-01-01 2010-01-01 false Property subject to forfeiture procedures. 356.1...

  20. Acquisition Policy and Procedures Program

    National Research Council Canada - National Science Library

    2001-01-01

    This Instruction establishes policies, responsibilities, and procedures for the procurement of goods and services to include supplies, equipment, publications, furniture, and information technology...

  1. Review on midurethral sling procedures for stress urinary incontinence

    Directory of Open Access Journals (Sweden)

    Nazura Bt Karim

    2015-05-01

    Full Text Available Minimally invasive suburethral slings, namely the retropubic suburethral sling or the tension-free vaginal tape (TVT, has become the mainstay for surgical management of moderate to severe stress urinary incontinence (SUI taking over the place of Burch's colposuspension after its introduction in the 1990s. Following the introduction of retropubic sling procedures are the transobturator (TVT-O procedures and the mini-sling procedures. This review attempts to summarize the current trend of midurethral sling (MUS procedures in the management of SUI.

  2. Report on COTECH test procedure and characterization techniques

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    that need to be attained for successful characterization of the planned demonstrators and it deals with the material characterization and prototype testing for the COTECH demonstrators. The summary of this report includes:  General description of COTECH industrial demonstrators  COTECH materials...... and material characterization techniques  Characterization techniques of the COTECH demonstrators  Functionality and lifecycle testing of the COTECH demonstrators Besides the general introduction and conclusion each section of the report is dedicated to the characterization techniques and test procedure.......Characterization techniques and test procedure requirements for innovative self-ligating dental brackets (EO) Section 5.Characterization techniques and test procedure requirements for smart diagnostic chips comprising a microfluidic channel system (GBO) Section 6.Characterization techniques and test procedure...

  3. Optimization of procedure for calibration with radiometer/photometer

    International Nuclear Information System (INIS)

    Detilly, Isabelle

    2009-01-01

    A test procedure for the radiometer/photometer calibrations mark International Light at the Laboratorio de Fotometria y Tecnologia Laser (LAFTA) de la Escuela de Ingenieria Electrica de la Universidad de Costa Rica is established. Two photometric banks are used as experimental set and two calibrations were performed of the International Light. A basic procedure established in the laboratory, is used for calibration from measurements of illuminance and luminous intensity. Some dependent variations of photometric banks used in the calibration process, the programming of the radiometer/photometer and the applied methodology showed the results. The procedure for calibration with radiometer/photometer can be improved by optimizing the programming process of the measurement instrument and possible errors can be minimized by using the recommended procedure. (author) [es

  4. Reforming China’s Criminal Procedure Law

    OpenAIRE

    Winckler, Hugo

    2014-01-01

    Sources:- Wang Jianxun, “The provisions of the reform of criminal procedural law legalising secret investigations are a step backwards,” Caijing wang, 5 September 2011.- Chen Youxi, “The legalisation of secret investigations is an important violation of political integrity,” Zhongguo wangluo dianshitai – CNTV web site, Opinion section, 27 November 2011.- Wu Zhehua, “Chen Weidong discusses reform of the criminal procedure law: Behind each article there is a story,” Zhongguoguangbo wang, 8 Marc...

  5. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  6. The Closing of the Insolvency Procedure

    Directory of Open Access Journals (Sweden)

    Cornelia Lefter

    2007-12-01

    Full Text Available The achievment of the balance between the offer and the demand in a market economy makes that some merchants win and others lose. Losing in business is a normal risk, usually assumed by any merchant. But when the merchant record losses, the issue is of engaging his responsibility before all those that may be damaged due to his negative results. Faced to this reality, the commercial legislation, by way of the collective procedure, has tried to found the most adequate means to reduce up to the maximum the negative influences that the losses beared by a merchant may have on his creditors. According to this, from the new law of the collective procedure (Law no. 85/2006 there have been analized those cases of closing the procedure and their effects which raised already problems in practice and aroused interesting doctrinal controversies.

  7. A manual of nuclear medicine procedures

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Nuclear medicine is a fast growing specialty. The procedures provide quantitative parameters of organ functions required for modern practice of medicine. With the development of new machines and increased application of computer software, the procedures are under continuous change. Some procedures have become outdated or redundant while new methods have been introduced to enhance the quality of information obtained from a particular application. Although there are a few books published abroad to inform doctors and technical staff about the procedures, a comprehensive source to give quick information about how different test are performed, particularly the new developments and the expected outcome both in normal and abnormal cases has been a long felt need. The physician ordering a Nuclear Medicine test also needs to know what patient preparations are required for optimal results, how to satisfy the queries of the patient particularly in respect of radiation exposure which sometimes can be a major concern of the patient. This manual has been prepared not only to describe technical details of various procedures that are currently practiced in Nuclear Medicine, but also to provide quick information for the doctors and health care personnel on how to inform the patients about the investigation for which they are being referred and how to interpret the results. Since there is no such comprehensive book published yet in Asia including South-East Asia, it is likely to be in great demand in the region. All students of Master Degree, M.D., DRM, DMRIT, M.Sc. (Nuclear Medicine) and technologists already working in various diagnostic centers will likely buy this book. General practitioners and specialists who refer patients for different radioisotope investigations may find this book useful for quick reference. (author)

  8. Parliamentary Pastries: Learning Parliamentary Procedure through Cookies

    Science.gov (United States)

    Toupence, Rachelle H.

    2008-01-01

    Parliamentary procedure is an integral part of the business of many recreation organizations, but students often perceive it to be difficult and irrelevant to their professional preparation. The activity uses the creation of a cookie recipe to practice the basic meeting business functions in parliamentary procedure. The cookie meeting is an active…

  9. Visualizing a Procedure with Nassi-Schneiderman Charts.

    Science.gov (United States)

    Weiss, Edmond H.

    1990-01-01

    Argues that Nassi-Schneiderman (NS) charts, when used to diagram human procedures, can eliminate prose ambiguities. Asserts that these devices provide most of the advantages of decision tables and trees. Suggests using NS charts in testing the logic and completeness of traditional procedures, or even in place of many traditional publications. (SG)

  10. 12 CFR 227.2 - Consumer complaint procedure.

    Science.gov (United States)

    2010-01-01

    ... convenience of the user, the revised text is set forth as follows: § 227.2 Consumer-complaint procedure. (a... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Consumer complaint procedure. 227.2 Section 227... SYSTEM UNFAIR OR DECEPTIVE ACTS OR PRACTICES (REGULATION AA) General Provisions § 227.2 Consumer...

  11. Software quality assurance procedures for radioactive waste risk assessment codes

    International Nuclear Information System (INIS)

    Hill, I.; Mayer, J.

    1990-01-01

    This support study for the evaluation of the safety of geological disposal systems is aimed at identifying the requirements for software quality assurance procedures for radioactive waste risk assessment codes, and to recommend appropriate procedures. The research covers: (i) the analysis of existing procedures and definition of requirements; (ii) a case study of the use of some existing procedures; (iii) the definition and the implementation of procedures. The report is supported by appendices that give more detail on the procedures recommended. It is intended to provide ideas on the steps that should be taken to ensure the quality of the programs used for assessment of the safety case for radioactive waste repositories, and does not represent the introduction of wholly new ideas or techniques. The emphasis throughout is on procedures that will be easily implemented, rather than on the fully rigorous procedures that are required for some application areas. The study has concentrated on measures that will increase the confidence in repository performance assessments among the wider scientific/engineering community, and the lay public

  12. Automatic control design procedures for restructurable aircraft control

    Science.gov (United States)

    Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.

    1985-01-01

    A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.

  13. 40 CFR 75.37 - Missing data procedures for moisture.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Missing data procedures for moisture... data procedures for moisture. (a) The owner or operator of a unit with a continuous moisture monitoring system shall substitute for missing moisture data using the procedures of this section. (b) Where no...

  14. Factory Acceptance Test Procedure Westinghouse 100 ton Hydraulic Trailer

    International Nuclear Information System (INIS)

    Aftanas, B.L.

    1994-01-01

    This Factory Acceptance Test Procedure (FAT) is for the Westinghouse 100 Ton Hydraulic Trailer. The trailer will be used for the removal of the 101-SY pump. This procedure includes: safety check and safety procedures; pre-operation check out; startup; leveling trailer; functional/proofload test; proofload testing; and rolling load test

  15. Patient radiation dose audits for fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Balter, Stephen; Rosenstein, Marvin; Miller, Donald L.; Schueler, Beth; Spelic, David

    2011-01-01

    Purpose: Quality management for any use of medical x-ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described. Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow-up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL. Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (K a,r ) (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median K a,r exceeds the 75th percentile of the ADS and (2) when the percent of instances where K a,r exceeds the facility-selected SRDL is greater for the FDS than for the ADS. Conclusions: Analysis of the two data sets (ADS and FDS) and of the

  16. 702AZ aging waste ventilation facility year 2000 test procedure

    International Nuclear Information System (INIS)

    Winkelman, W.D.

    1998-01-01

    This test procedure was developed to determine if the 702AZ Tank Ventilation Facility system is Year 2000 Compliant. The procedure provides detailed instructions for performing the operations necessary and documenting the results. This verification procedure will document that the 702AZ Facility Systems are year 2000 compliant and will correctly meet the criteria established in this procedure

  17. Evaluation of medical radiation exposure in pediatric interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, Valeria Coelho Costa; Navarro, Marcus Vinicius Teixeira; Oliveira, Aline da Silva Pacheco, E-mail: vccnavarro@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil); Maia, Ana Figueiredo [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Oliveira, Adriano Dias Dourado [Sociedade Brasileira de Hemodinamica e Cardiologia Intervencionista, Salvador, BA (Brazil)

    2012-07-15

    Objective: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. Materials and Methods: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. Results: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm{sup 2} and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm{sup 2} and 961.0 mGy. Conclusion: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates. (author)

  18. Defect assessment procedures at high temperature

    International Nuclear Information System (INIS)

    Ainsworth, R.A.

    1991-01-01

    A comprehensive assessment procedure for the high-temperature response of structures is being produced. The procedure is referred to as R5 and is written as a series of step-by-step instructions in a number of volumes. This paper considers in detail those parts of R5 which address the behaviour of defects. The defect assessment procedures may be applied to defects found in service, postulated defects, or defects formed during operation as a result of creep-fatigue loading. In the last case, a method is described for deducing from endurance data the number of cycles to initiate a crack of a specified size. Under steady loading, the creep crack tip parameter C * is used to assess crack growth. Under cyclic loading, the creep crack growth during dwell periods is stiell governed by C * but crack growth due to cyclic excursions must also be included. This cyclic crack growth is described by an effective stress intensity factor range. A feature of the R5 defect assessment procedures in that they are based on simplified methods and approximate reference stress methods are described which enable C * in a component to be evaluated. It is shown by comparison with theoretical calculations and experimental data that reliable estimates of C * and the associated crack growth are obtained provided realistic creep strain rate date are used in the reference stress approximation. (orig./HP)

  19. Procedures for field chemical analyses of water samples

    International Nuclear Information System (INIS)

    Korte, N.; Ealey, D.

    1983-12-01

    A successful water-quality monitoring program requires a clear understanding of appropriate measurement procedures in order to obtain reliable field data. It is imperative that the responsible personnel have a thorough knowledge of the limitations of the techniques being used. Unfortunately, there is a belief that field analyses are simple and straightforward. Yet, significant controversy as well as misuse of common measurement techniques abounds. This document describes procedures for field measurements of pH, carbonate and bicarbonate, specific conductance, dissolved oxygen, nitrate, Eh, and uranium. Each procedure section includes an extensive discussion regarding the limitations of the method as well as brief discussions of calibration procedures and available equipment. A key feature of these procedures is the consideration given to the ultimate use of the data. For example, if the data are to be used for geochemical modeling, more precautions are needed. In contrast, routine monitoring conducted merely to recognize gross changes can be accomplished with less effort. Finally, quality assurance documentation for each measurement is addressed in detail. Particular attention is given to recording sufficient information such that decisions concerning the quality of the data can be easily made. Application of the procedures and recommendations presented in this document should result in a uniform and credible water-quality monitoring program. 22 references, 4 figures, 3 tables

  20. FFTF fuel pin design procedure verification for transient operation

    International Nuclear Information System (INIS)

    Baars, R.E.

    1975-05-01

    The FFTF design procedures for evaluating fuel pin transient performance are briefly reviewed, and data where available are compared with design procedure predictions. Specifically, burst conditions derived from Fuel Cladding Transient Tester (FCTT) tests and from ANL loss-of-flow tests are compared with burst pressures computed using the design procedure upon which the cladding integrity limit was based. Failure times are predicted using the design procedure for evaluation of rapid reactivity insertion accidents, for five unterminated TREAT experiments in which well characterized fuel failures were deliberately incurred. (U.S.)