WorldWideScience

Sample records for primary graft failure

  1. Weighing of risk factors for penetrating keratoplasty graft failure: application of Risk Score System

    Directory of Open Access Journals (Sweden)

    Abdo Karim Tourkmani

    2017-03-01

    Full Text Available AIM: To analyze the relationship between the score obtained in the Risk Score System (RSS proposed by Hicks et al with penetrating keratoplasty (PKP graft failure at 1y postoperatively and among each factor in the RSS with the risk of PKP graft failure using univariate and multivariate analysis. METHODS: The retrospective cohort study had 152 PKPs from 152 patients. Eighteen cases were excluded from our study due to primary failure (10 cases, incomplete medical notes (5 cases and follow-up less than 1y (3 cases. We included 134 PKPs from 134 patients stratified by preoperative risk score. Spearman coefficient was calculated for the relationship between the score obtained and risk of failure at 1y. Univariate and multivariate analysis were calculated for the impact of every single risk factor included in the RSS over graft failure at 1y. RESULTS: Spearman coefficient showed statistically significant correlation between the score in the RSS and graft failure (P0.05 between diagnosis and lens status with graft failure. The relationship between the other risk factors studied and graft failure was significant (P<0.05, although the results for previous grafts and graft failure was unreliable. None of our patients had previous blood transfusion, thus, it had no impact. CONCLUSION: After the application of multivariate analysis techniques, some risk factors do not show the expected impact over graft failure at 1y.

  2. Warfarin improves the outcome of infrainguinal vein bypass grafting at high risk for failure.

    Science.gov (United States)

    Sarac, T P; Huber, T S; Back, M R; Ozaki, C K; Carlton, L M; Flynn, T C; Seeger, J M

    1998-09-01

    Patients with marginal venous conduit, poor arterial runoff, and prior failed bypass grafts are at high risk for infrainguinal graft occlusion and limb loss. We sought to evaluate the effects of anticoagulation therapy after autogenous vein infrainguinal revascularization on duration of patency, limb salvage rates, and complication rates in this subset of patients. This randomized prospective trial was performed in a university tertiary care hospital and in a Veterans Affairs Hospital. Fifty-six patients who were at high risk for graft failure were randomized to receive aspirin (24 patients, 27 bypass grafts) or aspirin and warfarin (WAR; 32 patients, 37 bypass grafts). All patients received 325 mg of aspirin each day, and the patients who were randomized to warfarin underwent anticoagulation therapy with heparin immediately after surgery and then were started on warfarin therapy to maintain an international normalized ratio between 2 and 3. Perioperative blood transfusions and complications were compared with the Student t test or with the chi2 test. Graft patency rates, limb salvage rates, and survival rates were compared with the Kaplan-Meier method and the log-rank test. Sixty-one of the 64 bypass grafts were performed for rest pain or tissue loss, and 3 were performed for short-distance claudication. There were no differences between the groups in ages, indications, bypass graft types, risk classifications (ie, conduit, runoff, or graft failure), or comorbid conditions (except diabetes mellitus). The cumulative 5-year survival rate was similar between the groups. The incidence rate of postoperative hematoma (32% vs 3.7%; P = .004) was greater in the WAR group, but no differences were seen between the WAR group and the aspirin group in the number of packed red blood cells transfused, in the incidence rate of overall nonhemorrhagic wound complications, or in the overall complication rate (62% vs 52%). The immediate postoperative primary graft patency rates (97

  3. A dynamical system that describes vein graft adaptation and failure.

    Science.gov (United States)

    Garbey, Marc; Berceli, Scott A

    2013-11-07

    Adaptation of vein bypass grafts to the mechanical stresses imposed by the arterial circulation is thought to be the primary determinant for lesion development, yet an understanding of how the various forces dictate local wall remodeling is lacking. We develop a dynamical system that summarizes the complex interplay between the mechanical environment and cell/matrix kinetics, ultimately dictating changes in the vein graft architecture. Based on a systematic mapping of the parameter space, three general remodeling response patterns are observed: (1) shear stabilized intimal thickening, (2) tension induced wall thinning and lumen expansion, and (3) tension stabilized wall thickening. Notable is our observation that the integration of multiple feedback mechanisms leads to a variety of non-linear responses that would be unanticipated by an analysis of each system component independently. This dynamic analysis supports the clinical observation that the majority of vein grafts proceed along an adaptive trajectory, where grafts dilate and mildly thicken in response to the increased tension and shear, but a small portion of the grafts demonstrate a maladaptive phenotype, where progressive inward remodeling and accentuated wall thickening lead to graft failure. © 2013 The Authors. Published by Elsevier Ltd. All rights reserved.

  4. High risk of graft failure in patients with anti-HLA antibodies undergoing haploidentical stem-cell transplantation.

    Science.gov (United States)

    Ciurea, Stefan O; de Lima, Marcos; Cano, Pedro; Korbling, Martin; Giralt, Sergio; Shpall, Elizabeth J; Wang, Xuemei; Thall, Peter F; Champlin, Richard E; Fernandez-Vina, Marcelo

    2009-10-27

    BACKGROUND.: Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSA) have been implicated in graft rejection in solid organ transplantation, their role in hematopoietic stem-cell transplantation remains unclear. METHODS.: To address the hypothesis that the presence of DSA contributes to the development graft failure, we tested 24 consecutive patients for the presence of anti-HLA antibodies determined by a sensitive and specific solid-phase/single-antigen assay. The study included a total of 28 haploidentical transplants, each with 2 to 5 HLA allele mismatches, at a single institution, from September 2005 to August 2008. RESULTS.: DSA were detected in five patients (21%). Three of four (75%) patients with DSA before the first transplant failed to engraft, compared with 1 of 20 (5%) without DSA (P=0.008). All four patients who experienced primary graft failure had second haploidentical transplants. One patient developed a second graft failure with persistent high DSA levels, whereas three engrafted, two of them in the absence of DSA. No other known factors that could negatively influence engraftment were associated with the development of graft failure in these patients. CONCLUSIONS.: These results suggest that donor-specific anti-HLA antibodies are associated with a high rate of graft rejection in patients undergoing haploidentical stem-cell transplantation. Anti-HLA sensitization should be evaluated routinely in hematopoietic stem-cell transplantation with HLA mismatched donors.

  5. PIRCHE-II Is Related to Graft Failure after Kidney Transplantation

    Science.gov (United States)

    Geneugelijk, Kirsten; Niemann, Matthias; Drylewicz, Julia; van Zuilen, Arjan D.; Joosten, Irma; Allebes, Wil A.; van der Meer, Arnold; Hilbrands, Luuk B.; Baas, Marije C.; Hack, C. Erik; van Reekum, Franka E.; Verhaar, Marianne C.; Kamburova, Elena G.; Bots, Michiel L.; Seelen, Marc A. J.; Sanders, Jan Stephan; Hepkema, Bouke G.; Lambeck, Annechien J.; Bungener, Laura B.; Roozendaal, Caroline; Tilanus, Marcel G. J.; Vanderlocht, Joris; Voorter, Christien E.; Wieten, Lotte; van Duijnhoven, Elly M.; Gelens, Mariëlle; Christiaans, Maarten H. L.; van Ittersum, Frans J.; Nurmohamed, Azam; Lardy, Junior N. M.; Swelsen, Wendy; van der Pant, Karlijn A.; van der Weerd, Neelke C.; ten Berge, Ineke J. M.; Bemelman, Fréderike J.; Hoitsma, Andries; van der Boog, Paul J. M.; de Fijter, Johan W.; Betjes, Michiel G. H.; Heidt, Sebastiaan; Roelen, Dave L.; Claas, Frans H.; Otten, Henny G.; Spierings, Eric

    2018-01-01

    Individual HLA mismatches may differentially impact graft survival after kidney transplantation. Therefore, there is a need for a reliable tool to define permissible HLA mismatches in kidney transplantation. We previously demonstrated that donor-derived Predicted Indirectly ReCognizable HLA Epitopes presented by recipient HLA class II (PIRCHE-II) play a role in de novo donor-specific HLA antibodies formation after kidney transplantation. In the present Dutch multi-center study, we evaluated the possible association between PIRCHE-II and kidney graft failure in 2,918 donor–recipient couples that were transplanted between 1995 and 2005. For these donors–recipients couples, PIRCHE-II numbers were related to graft survival in univariate and multivariable analyses. Adjusted for confounders, the natural logarithm of PIRCHE-II was associated with a higher risk for graft failure [hazard ratio (HR): 1.13, 95% CI: 1.04–1.23, p = 0.003]. When analyzing a subgroup of patients who had their first transplantation, the HR of graft failure for ln(PIRCHE-II) was higher compared with the overall cohort (HR: 1.22, 95% CI: 1.10–1.34, p < 0.001). PIRCHE-II demonstrated both early and late effects on graft failure in this subgroup. These data suggest that the PIRCHE-II may impact graft survival after kidney transplantation. Inclusion of PIRCHE-II in donor-selection criteria may eventually lead to an improved kidney graft survival. PMID:29556227

  6. The Incidence and Risk Factors for Lower Limb Skin Graft Failure

    Directory of Open Access Journals (Sweden)

    Sumeet Reddy

    2014-01-01

    Full Text Available Lower limb skin grafts are thought to have higher failure rates than skin grafts in other sites of the body. Currently, there is a paucity of literature on specific factors associated with lower limb skin graft failure. We present a series of 70 lower limb skin grafts in 50 patients with outcomes at 6 weeks. One-third of lower limb skin grafts went on to fail with increased BMI, peripheral vascular disease, and immunosuppressant medication use identified as significant risk factors.

  7. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  8. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  9. Prolonged warm ischemia time is associated with graft failure and mortality after kidney transplantation.

    Science.gov (United States)

    Tennankore, Karthik K; Kim, S Joseph; Alwayn, Ian P J; Kiberd, Bryce A

    2016-03-01

    Warm ischemia time is a potentially modifiable insult to transplanted kidneys, but little is known about its effect on long-term outcomes. Here we conducted a study of United States kidney transplant recipients (years 2000-2013) to determine the association between warm ischemia time (the time from organ removal from cold storage to reperfusion with warm blood) and death/graft failure. Times under 10 minutes were potentially attributed to coding error. Therefore, the 10-to-under-20-minute interval was chosen as the reference group. The primary outcome was mortality and graft failure (return to chronic dialysis or preemptive retransplantation) adjusted for recipient, donor, immunologic, and surgical factors. The study included 131,677 patients with 35,901 events. Relative to the reference patients, times of 10 to under 20, 20 to under 30, 30 to under 40, 40 to under 50, 50 to under 60, and 60 and more minutes were associated with hazard ratios of 1.07 (95% confidence interval, 0.99-1.15), 1.13 (1.06-1.22), 1.17 (1.09-1.26), 1.20 (1.12-1.30), and 1.23 (1.15-1.33) for the composite event, respectively. Association between prolonged warm ischemia time and death/graft failure persisted after stratification by donor type (living vs. deceased donor) and delayed graft function status. Thus, warm ischemia time is associated with adverse long-term patient and graft survival after kidney transplantation. Identifying strategies to reduce warm ischemia time is an important consideration for future study. Copyright © 2015 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  10. Chronicity of Anterior Cruciate Ligament Deficiency, Part 2: Radiographic Predictors of Early Graft Failure.

    Science.gov (United States)

    Tanaka, Yoshinari; Kita, Keisuke; Takao, Rikio; Amano, Hiroshi; Uchida, Ryohei; Shiozaki, Yoshiki; Yonetani, Yasukazu; Kinugasa, Kazutaka; Mae, Tatsuo; Horibe, Shuji

    2018-02-01

    Accumulating evidence suggests that long-term anterior cruciate ligament (ACL) deficiency can give rise to an abnormal tibiofemoral relationship and subsequent intra-articular lesions. However, the effects of chronic ACL deficiency (ACLD) on early graft failure after anatomic reconstruction remain unclear. We hypothesized that patients with long-term ACLD lasting more than 5 years would have a greater rate of early graft failure due to insufficient intraoperative reduction of the tibia and that the preoperative and immediately postoperative abnormal tibiofemoral relationship in the sagittal plane, such as anterior tibial subluxation (ATS), would correlate with the graft status on postoperative magnetic resonance imaging (MRI). Cohort study; Level of evidence, 3. A total of 358 patients who had undergone anatomic ACL reconstruction with hamstring grafts were divided into 5 groups based on chronicity of ACLD: (1) 0 to 6 months, (2) 6 months to 1 year, (3) 1 to 2 years, (4) 2 to 5 years, and (5) longer than 5 years. Preoperatively and immediately postoperatively, lateral radiographs in full extension were taken in all patients to evaluate the tibiofemoral relationship, specifically with regard to ATS, space for the ACL (sACL), and extension angle. All patients underwent MRI at 6 months to reveal graft status. Groups with a high rate of graft failure were further analyzed to compare demographic and radiographic factors between the intact and failure subgroups, followed by multivariate logistic regression analysis to identify predisposing factors. Graft failure without trauma was observed in 4 (1.8%), 0 (0%), 1 (3.7%), 3 (9.7%), and 8 patients (17.7%) in groups 1, 2, 3, 4, and 5, respectively. Of the 76 patients in groups 4 and 5, significant differences were noted between the failure and intact subgroups in preoperative ATS (4.9 vs 2.4 mm, respectively; P failure (odds ratio, 3.2; 95% CI, 1.37-7.46). Early graft failure at 6 months increased in patients with ACLD

  11. Primary contraction of skin grafts: a porcine preliminary study

    Directory of Open Access Journals (Sweden)

    Alexander Bogdanov Berezovsky

    2015-03-01

    Full Text Available Aim: Skin grafting is a common clinical practice for plastic surgeons, yet primary contraction of these grafts is a neglected topic. This study was designed to investigate primary contraction and introduce the shape of skin graft as a possible factor that modifies primary contraction behavior, using porcine models. Methods: In the first series, full-thickness skin grafts (FTSGs and split-thickness skin grafts (STSGs were compared. In a second series, how the shape of the skin graft affected the degree of contraction was examined. Results: The mean percentage of FTSG shrinkage was 12.04%, and the median was 12.18%. The mean percentage of STSG shrinkage was 6.87%, and the median was 5%. Circle-shaped and square-shaped FTSGs showed mean/median graft shrinkage of 5.83%/6.93% and 4.15%/3.75%, respectively. In STSGs, the circle-shaped and square-shaped grafts had mean/median graft shrinkage of 1.07%/0% and 0.31%/0%, respectively. Conclusion: Our preliminary report revealed an expected greater shrinkage of FTSGs compared with STSGs. Furthermore, in a limited number of specimens, the shape of the skin graft seemed to affect the primary contraction of the STSGs.

  12. Downstream anastomotic hyperplasia. A mechanism of failure in Dacron arterial grafts.

    Science.gov (United States)

    LoGerfo, F W; Quist, W C; Nowak, M D; Crawshaw, H M; Haudenschild, C C

    1983-01-01

    The precise location and progression of anastomotic hyperplasia and its possible relationship to flow disturbances was investigated in femoro-femoral Dacron grafts in 28 dogs. In 13 grafts, the outflow from the end-to-side downstream anastomosis was bidirectional (BDO), and in 15 it was unidirectional (UDO) (distally). Grafts were electively removed at intervals of two to 196 days or at the time of thrombosis. Each anastomosis and adjacent artery was perfusion-fixed and sectioned sagittally. The mean sagittal section was projected onto a digitized pad, and the total area of hyperplasia internal to the arterial internal elastic lamina and within the adjacent graft was integrated by computer. The location of the hyperplasia was compared with previously established sites of flow separation and stagnation. The observation was made that hyperplasia is significantly greater at the downstream, as compared with the upstream, anastomosis in both groups (BDO = p less than 0.001 and UDO = p less than 0.001) (analysis of variance for independent groups). Furthermore, this downstream hyperplasia was progressive with time (BDO p less than 0.01) (UDO p less than 0.01); Spearman Rank Correlation. There was no significant increase in the extent of downstream hyperplasia where flow separation was known to be greater (BDO). Five grafts failed (three BDO, two UDO), as a result of complete occlusion of the downstream anastomosis by fibrous hyperplasia. Transmission electron microscopy showed the hyperplasia to consist of collagen-producing smooth muscle cells. Anastomotic hyperplasia is significantly greater at the downstream anastomosis, is progressive with time, and is the primary cause of failure of Dacron arterial grafts in this model. Quantitative analysis of downstream anastomotic hyperplasia may be a valuable measure of the biocompatibility of Dacron grafts. Images Fig. 2. Fig. 3. Fig. 5. Fig. 6. Fig. 7. Fig. 8. PMID:6219641

  13. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up

    DEFF Research Database (Denmark)

    Lehnert, Per; Møller, Christian H; Damgaard, Sune

    2015-01-01

    on graft vessel type, anastomatic configuration, and coronary artery size. RESULTS: Nine hundred eighty-two coronary anastomoses were performed of which 12% had signs of graft failure at one year angiographic follow-up. In internal mammary arteries (IMAs), analysis showed a 4% decrease in graft failure......BACKGROUND: Transit-time flow measurement (TTFM) is a commonly used intraoperative method for evaluation of coronary artery bypass graft (CABG) anastomoses. This study was undertaken to determine whether TTFM can also be used to predict graft patency at one year postsurgery. METHODS: Three hundred...... forty-five CABG patients with intraoperative graft flow measurements and one year angiographic follow-up were analyzed. Graft failure was defined as more than 50% stenosis including the "string sign." Logistic regression analysis was used to analyze the risk of graft failure after one year based...

  14. Expansion of donor-reactive host T cells in primary graft failure after allogeneic hematopoietic SCT following reduced-intensity conditioning.

    Science.gov (United States)

    Koyama, M; Hashimoto, D; Nagafuji, K; Eto, T; Ohno, Y; Aoyama, K; Iwasaki, H; Miyamoto, T; Hill, G R; Akashi, K; Teshima, T

    2014-01-01

    Graft rejection remains a major obstacle in allogeneic hematopoietic SCT following reduced-intensity conditioning (RIC-SCT), particularly after cord blood transplantation (CBT). In a murine MHC-mismatched model of RIC-SCT, primary graft rejection was associated with activation and expansion of donor-reactive host T cells in peripheral blood and BM early after SCT. Donor-derived dendritic cells are at least partly involved in host T-cell activation. We then evaluated if such an expansion of host T cells could be associated with graft rejection after RIC-CBT. Expansion of residual host lymphocytes was observed in 4/7 patients with graft rejection at 3 weeks after CBT, but in none of the 17 patients who achieved engraftment. These results suggest the crucial role of residual host T cells after RIC-SCT in graft rejection and expansion of host T cells could be a marker of graft rejection. Development of more efficient T cell-suppressive conditioning regimens may be necessary in the context of RIC-SCT.

  15. The effect of ABO blood incompatibility on corneal transplant failure in conditions with low-risk of graft rejection.

    Science.gov (United States)

    Dunn, Steven P; Stark, Walter J; Stulting, R Doyle; Lass, Jonathan H; Sugar, Alan; Pavilack, Mark A; Smith, Patricia W; Tanner, Jean Paul; Dontchev, Mariya; Gal, Robin L; Beck, Roy W; Kollman, Craig; Mannis, Mark J; Holland, Edward J

    2009-03-01

    To determine whether corneal graft survival over a 5-year follow-up period was affected by ABO blood type compatibility in participants in the Cornea Donor Study undergoing corneal transplantation principally for Fuchs dystrophy or pseudophakic corneal edema, conditions at low-risk for graft rejection. Multi-center prospective, double-masked, clinical trial. ABO blood group compatibility was determined for 1,002 donors and recipients. During a 5-year follow-up period, episodes of graft rejection were documented, and graft failures were classified as to whether or not they were attributable to immunologic rejection. Endothelial cell density was determined by a central reading center for a subset of subjects. ABO donor-recipient incompatibility was not associated with graft failure attributable to any cause including graft failure because of rejection, or with the occurrence of a rejection episode. The 5-year cumulative incidence of graft failure attributable to rejection was 32 (6%) for recipients with ABO recipient-donor compatibility and 12 (4%) for those with ABO incompatibility (hazard ratio, 0.65; 95% confidence interval, 0.33 to 1.25; P = .20). The 5-year incidence for a definite rejection episode, irrespective of whether graft failure ultimately occurred, was 64 (12%) for ABO compatible compared with 25 (8%) for ABO incompatible cases (P = .09). Among clear grafts at 5 years, percent loss of endothelial cells was similar in ABO compatible and incompatible cases. In patients undergoing penetrating keratoplasty for Fuchs dystrophy or pseudophakic corneal edema, ABO matching is not indicated since ABO incompatibility does not increase the risk of transplant failure attributable to graft rejection.

  16. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  17. Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

    Science.gov (United States)

    Greenlee, Emily C; Kwon, Young H

    2008-06-01

    Glaucoma after penetrating keratoplasty is a frequently observed post-operative complication and is a risk factor for graft failure. Penetrating keratoplasty performed for aphakic and pseudophakic bullous keratopathy and inflammatory conditions are more likely to cause postoperative glaucoma compared with keratoconus and Fuchs' endothelial dystrophy. The intraocular pressure elevation may occur immediately after surgery or in the early to late postoperative period. Early postoperative causes of glaucoma include pre-existing glaucoma, retained viscoelastic, hyphema, inflammation, pupillary block, aqueous misdirection, or suprachoroidal hemorrhage. Late causes include pre-existing glaucoma, angle-closure glaucoma, ghost cell glaucoma, suprachoroidal hemorrhage, and steroid-induced glaucoma. Determining the cause of IOP elevation can help guide therapeutic intervention. Treatments for refractory glaucoma include topical anti-glaucoma medications such as beta-adrenergic blockers. Topical carbonic anhydrase inhibitors, miotic agents, adrenergic agonists, and prostaglandin analogs should be used with caution in the post-keratoplasty patient, because of the possibility of corneal decompensation, cystoid macular edema, or persistent inflammation. Various glaucoma surgical treatments have reported success in post-keratoplasty glaucoma. Trabeculectomy with mitomycin C can be successful in controlling IOP without the corneal toxicity noted with 5-fluorouracil. Glaucoma drainage devices have successfully controlled intraocular pressure in postkeratoplasty glaucoma; this is, however, associated with increased risk of graft failure. Placement of the tube through the pars plana may improve graft success compared with implantation within the anterior chamber. In addition, cyclophotocoagulation remains a useful procedure for eyes that have refractory glaucoma despite multiple surgical interventions.

  18. Dermis-Fat Graft in Children as Primary and Secondary Orbital Implant.

    Science.gov (United States)

    Quaranta-Leoni, Francesco M; Sposato, Sabrina; Raglione, Pietro; Mastromarino, Angelo

    2016-01-01

    To report the experience with the use of dermis-fat graft in the pediatric population and to evaluate the outcome of this procedure as a primary or secondary orbital implant. Case series. Analysis of the clinical charts of 22 patients. Age at the time of surgery ranged from 2.1 to 13 years. Three patients affected were submitted to evisceration with primary dermis-fat graft. Six patients had explantation of exposed implants and a replacement with a dermis-fat graft. Three patients had a dermis-fat graft to repair contracted sockets. Ten patients were affected by congenital anophthalmia: 4 patients had a primary dermis-fat graft, 6 patients had a removal of a socket expander, or an orbital spherical expander, or pellet expanders and a replacement with a dermis-fat graft. This study adheres to the principles outlined in the Declaration of Helsinki. The patients' follow up ranged between 2.5 and 8 years. Only 1 child who had a primary dermis-fat graft experienced excessive growth of the implant, managed by surgical debulking. In the end, all the patients showed satisfactory orbital volume along with adequate fornices. The dermis-fat graft as a primary implant may be useful in children with severe scleromalacia or following ocular trauma. It is a suitable option in children affected by congenital anophthalmia as it helps continued socket expansion. It can also be considered in the pediatric population to address the volume deficit following explantation of exposed implants and in contracted sockets.

  19. Predicting kidney graft failure using time-dependent renal function covariates

    NARCIS (Netherlands)

    de Bruijne, Mattheus H. J.; Sijpkens, Yvo W. J.; Paul, Leendert C.; Westendorp, Rudi G. J.; van Houwelingen, Hans C.; Zwinderman, Aeilko H.

    2003-01-01

    Chronic rejection and recurrent disease are the major causes of late graft failure in renal transplantation. To assess outcome, most researchers use Cox proportional hazard analysis with time-fixed covariates. We developed a model adding time-dependent renal function covariates to improve the

  20. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    Science.gov (United States)

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  1. Expanding arch aneurysm causing a "kink" in a Bentall graft and heart failure.

    Science.gov (United States)

    Al-Mohaissen, Maha A; Skarsgard, Peter; Khoo, Clarence; Virani, Sean A; Munt, Brad; Leipsic, Jonathon; Ignaszewski, Andrew

    2012-07-01

    Marfan syndrome is associated with a high incidence of aortic root aneurysm and life-threatening aortic dissection. With the successful use of surgical aortic root replacement, dissection-related mortality has been significantly reduced. We present the case of a patient with Marfan syndrome who presented with heart failure secondary to an unusual graft-related complication 14 years after a Bentall procedure. Investigations revealed a supra-aortic stenosis resulting from a kink in the Bentall graft caused by pressure from an expanding aortic arch aneurysm. The patient underwent surgery with improvement in his ejection fraction and heart failure symptoms.

  2. Primary graft dysfunction of the liver: definitions, diagnostic criteria and risk factors.

    Science.gov (United States)

    Neves, Douglas Bastos; Rusi, Marcela Balbo; Diaz, Luiz Gustavo Guedes; Salvalaggio, Paolo

    2016-01-01

    Primary graft dysfunction is a multifactorial syndrome with great impact on liver transplantation outcomes. This review article was based on studies published between January 1980 and June 2015 and retrieved from PubMed database using the following search terms: "primary graft dysfunction", "early allograft dysfunction", "primary non-function" and "liver transplantation". Graft dysfunction describes different grades of graft ischemia-reperfusion injury and can manifest as early allograft dysfunction or primary graft non-function, its most severe form. Donor-, surgery- and recipient-related factors have been associated with this syndrome. Primary graft dysfunction definition, diagnostic criteria and risk factors differ between studies. RESUMO A disfunção primária do enxerto hepático é uma síndrome multifatorial com grande impacto no resultado do transplante de fígado. Foi realizada uma ampla revisão da literatura, consultando a base de dados PubMed, em busca de estudos publicados entre janeiro de 1980 e junho de 2015. Os termos descritivos utilizados foram: "primary graft dysfunction", "early allograft dysfunction", "primary non-function" e "liver transplantation". A disfunção traduz graus diferentes da lesão de isquemia e reperfusão do órgão, e pode se manifestar como disfunção precoce ou, na forma mais grave, pelo não funcionamento primário do enxerto. Fatores relacionados ao doador, ao transplante e ao receptor contribuem para essa síndrome. Existem definições diferentes na literatura quanto ao diagnóstico e aos fatores de risco associados à disfunção primária.

  3. Primary nerve grafting: A study of revascularization.

    Science.gov (United States)

    Chalfoun, Charbel; Scholz, Thomas; Cole, Matthew D; Steward, Earl; Vanderkam, Victoria; Evans, Gregory R D

    2003-01-01

    It was the purpose of this study to evaluate the revascularization of primary nerve repair and grafts using orthogonal polarization spectral (OPS) (Cytometrix, Inc.) imaging, a novel method for real-time evaluation of microcirculatory blood flow. Twenty male Sprague Dawley rats (250 g) were anesthetized with vaporized halothane and surgically prepared for common peroneal nerve resection. Group I animals (n = 10) underwent primary neurorraphy following transection, utilizing a microsurgical technique with 10-0 nylon suture. Group II (n = 10) animals had a 7-mm segment of nerve excised, reversed, and subsequently replaced as a nerve graft under similar techniques. All animals were evaluated using the OPS imaging system on three portions (proximal, transection site/graft, and distal) of the nerve following repair or grafting. Reevaluation of 5 animals randomly selected from each group using the OPS imaging system was again performed on days 14 and 28 following microsurgical repair/grafting. Values were determined by percent change in vascularity of the common peroneal nerve at 0 hr following surgery. Real-time evaluation of blood flow was utilized as an additional objective criterion. Percent vascularity in group I and II animals increased from baseline in all segments at day 14. By day 28, vascularity in nerves of group I rats decreased in all segments to values below baseline, with the exception of the transection site, which remained at a higher value than obtained directly after surgical repair. In group II animals, vascularity remained above baseline in all segments except the distal segment, which returned to vascularity levels similar to those at 0 hr. Further, occlusion of the vessels demonstrated in the graft and distal segments following initial transection appeared to be corrected. This study suggests that revascularization may occur via bidirectional inosculation with favored proximal vascular growth advancement. The use of real-time imaging offers a

  4. Cardiac retransplantation is an efficacious therapy for primary cardiac allograft failure

    Directory of Open Access Journals (Sweden)

    Acker Michael A

    2008-05-01

    Full Text Available Abstract Background Although orthotopic heart transplantation has been an effective treatment for end-stage heart failure, the incidence of allograft failure has increased, necessitating treatment options. Cardiac retransplantation remains the only viable long-term solution for end-stage cardiac allograft failure. Given the limited number of available donor hearts, the long term results of this treatment option need to be evaluated. Methods 709 heart transplants were performed over a 20 year period at our institution. Repeat cardiac transplantation was performed in 15 patients (2.1%. A retrospective analysis was performed to determine the efficacy of cardiac retransplantation. Variables investigated included: 1 yr and 5 yr survival, length of hospitalization, post-operative complications, allograft failure, recipient and donor demographics, renal function, allograft ischemic time, UNOS listing status, blood group, allograft rejection, and hemodynamic function. Results Etiology of primary graft failure included transplant arteriopathy (n = 10, acute rejection (n = 3, hyperacute rejection (n = 1, and a post-transplant diagnosis of metastatic melanoma in the donor (n = 1. Mean age at retransplantation was 45.5 ± 9.7 years. 1 and 5 year survival for retransplantation were 86.6% and 71.4% respectively, as compared to 90.9% and 79.1% for primary transplantation. Mean ejection fraction was 67.3 ± 12.2% at a mean follow-up of 32.6 ± 18.5 mos post-retransplant; follow-up biopsy demonstrated either ISHLT grade 1A or 0 rejection (77.5 ± 95.7 mos post-transplant. Conclusion Cardiac retransplantation is an efficacious treatment strategy for cardiac allograft failure.

  5. Boston Type 1 Keratoprosthesis versus Repeat Donor Keratoplasty for Corneal Graft Failure: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ahmad, Sumayya; Mathews, Priya M; Lindsley, Kristina; Alkharashi, Majed; Hwang, Frank S; Ng, Sueko M; Aldave, Anthony J; Akpek, Esen Karamursel

    2016-01-01

    To compare repeat penetrating keratoplasty (PK) with Boston type I keratoprosthesis (KPro) implantation for full-thickness donor corneal graft failure. Previous donor graft failure is a common indication for both PK and KPro implantation. Selection of the surgical procedure is entirely dependent on the surgeon because there are no studies available for guidance. Therefore, a systematic review was undertaken to examine vision, device retention, graft clarity, and postoperative glaucoma and infection outcomes after repeat PK versus KPro implantation. Articles with data regarding repeat PK published between 1990 and 2014 were identified in PubMed, EMBASE, the Latin American and Caribbean Health Sciences Literature Database, and the Cochrane Central Register of Controlled Trials and were reviewed. Results were compared with a retrospective review of consecutive, nonrandomized, longitudinal case series of KPro implantations performed at 5 tertiary care centers in the United States. Visual acuity at 2 years was the primary outcome measure. The proportion of clear grafts in the repeat PK group, device retention in the KPro group, and the development of postoperative glaucoma and infection were secondary outcome measures. The search strategy identified 17 128 articles in the PK analysis. After screening, 26 studies (21 case series and 5 cohort studies) were included in the review. Pooled analysis of the 26 unique studies demonstrated a 42% (95% confidence interval [CI], 30%-56%) likelihood of maintaining 20/200 or better at 2 years after repeat PK, compared with an 80% (95% CI, 68%-88%) probability with KPro implantation. The probability of maintaining a clear graft at 5 years was 47% (95% CI, 40%-54%) after repeat PK, whereas the probability of retention of the KPro at 5 years was 75% (95% CI, 64%-84%). The rate of progression of glaucoma at 3 years was 25% (95% CI, 10%-44%) after repeat PK and 30% in the KPro cohort. These results demonstrate favorable outcomes of KPro

  6. Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device.

    Science.gov (United States)

    Iverson, Shawn M; Spierer, Oriel; Papachristou, George C; Feuer, William J; Shi, Wei; Greenfield, David S; O'Brien, Terrence P

    2018-02-01

    To compare corneal graft survival rates after penetrating keratoplasty (PK) and Descemet's stripping endothelial keratoplasty (DSEK) in patients with a glaucoma drainage device (GDD) or medically managed glaucoma. A retrospective chart review was conducted on consecutive patients who underwent primary PK or primary DSEK. Inclusion criteria consisted of eyes with a diagnosis of glaucoma prior to corneal transplantation and a minimum of 6 months of follow-up. Graft failure was defined as an edematous cornea with failure to maintain deturgescence lasting beyond a period of 1 month of intense steroid therapy or vascularization and scarring resulting in irreversible loss of central graft clarity. Corneal graft survival was calculated using Kaplan-Meier survival analysis. Patients were divided into four groups: GDD-PK, GDD-DSEK, medical-PK and medical-DSEK. Fifty-six eyes of 56 patients were identified as meeting inclusion criteria. Among eyes with a GDD, there was no difference in the proportion of failures between PK grafts (48%) and DSEK grafts (50%) (p = 0.90). Failure occurred earlier in DSEK recipients compared to PK recipients, 5.82 ± 6.77 months versus 14.40 ± 7.70 months, respectively (p = 0.04). A Kaplan-Meier analysis did not identify a difference between the four groups with respect to graft failure (p = 0.52). There is no significant difference in graft survival rates between medically and surgically treated glaucoma patients for either PK or DSEK grafts. In patients with GDD, graft failure occurs earlier in DSEK compared to PK.

  7. A data science approach for quantifying spatio-temporal effects to graft failures in organ transplantation.

    Science.gov (United States)

    Pinheiro, Diego; Hamad, Farag; Cadeiras, Martin; Menezes, Ronaldo; Nezamoddini-Kachouie, Nezamoddin

    2016-08-01

    The transplantation of solid organs is one of the most important accomplishments of modern medicine. Yet, organ shortage is a major public health issue; 8,000 people died while waiting for an organ in 2014. Meanwhile, the allocation system currently implemented can lead to organs being discarded and the medical community still investigates factors that affects early graft failure such as distance and ischemic time. In this paper, we investigate early graft failure under a spatio-temporal perspective using a data science unified approach for all six organs that is based on complementary cumulative analysis of both distance and ischemic time. Interestingly, although distance seems to highly affect some organs (e.g. liver), it appears to have no effect on others (e.g. kidney). Similarly, the results on ischemic time confirm it affects early graft failure with higher influence for some organs such as (e.g. heart) and lower influence for others such as (e.g. kidney). This poses the question whether the allocation policies should be individually designed for each organ in order to account for their particularities as shown in this work.

  8. [Extracorporeal membrane oxygenation in primary graft dysfunction in a paediatric double lung transplant: presentation of a case].

    Science.gov (United States)

    López-Cantero, M; Grisolía, A L; Vicente, R; Moreno, I; Ramos, F; Porta, J; Torregrosa, S

    2014-04-01

    Primary graft dysfunction is a leading cause of morbimortality in the immediate postoperative period of patients undergoing lung transplantation. Among the treatment options are: lung protective ventilatory strategies, nitric oxide, lung surfactant therapy, and supportive treatment with extracorporeal membrane oxygenation (ECMO) as a bridge to recovery of lung function or re-transplant. We report the case of a 9-year-old girl affected by cystic fibrosis who underwent double-lung transplantation complicated with a severe primary graft dysfunction in the immediate postoperative period and refractory to standard therapies. Due to development of multiple organ failure, it was decided to insert arteriovenous ECMO catheters (pulmonary artery-right atrium). The postoperative course was satisfactory, allowing withdrawal of ECMO on the 5th post-surgical day. Currently the patient survives free of rejection and with an excellent quality of life after 600 days of follow up. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  9. Persistent hyperparathyroidism as a risk factor for long-term graft failure: the need to discuss indication for parathyroidectomy.

    Science.gov (United States)

    Araujo, Maria Júlia Correia Lima Nepomuceno; Ramalho, Janaina Almeida Mota; Elias, Rosilene Motta; Jorgetti, Vanda; Nahas, William; Custodio, Melani; Moysés, Rosa M A; David-Neto, Elias

    2018-01-10

    Although a successful kidney transplant (KTx) improves most of the mineral and bone disorders (MBD) produced by chronic kidney disease (CKD), hyperparathyroidism may persist (pHPT). Current guidelines recommend parathyroidectomy if serum parathormone is persistently elevated 1 year after KTx, because pHPT has been recently associated with poor graft outcomes. However, whether patients with pHPT and adequate renal function are at risk for long-term graft failure is unknown. Longitudinal follow-up of 911 adults submitted to KTx between January 2005 and December 2014, with estimated glomerular filtration rate (eGFR) ≥ 30 mL/min 1 year after surgery. Clinical and laboratory data were collected from electronic database. Graft failure was defined as return to dialysis. Overall, 62% of the patients were classified as having pHPT 1 year after KTx. After a mean follow-up time of 47 months, there were 59 graft failures (49 in pHPT and 10 in non-pHPT group, P = .003). At last follow-up, death-censored graft survival was lower in the pHPT group (P = .009), even after adjustment for age at KTx, donor age, donor type, acute rejection, parathyroidectomy, and eGFR at 1 year after transplantation (odds ratio [OR] 1.99; 1.004-3.971; P = .049). A PTH of 150 pg/mL at 6 months was the best cutoff to predict pHPT at 1 year (specificity = 92.1%). Having pHPT after a successful KTx increases the long-term risk of death-censored graft failure. This result highlights the need for better recognition and management of CKD-MBD before and during the first year after KTx, and opens a discussion on the more appropriate timing to perform parathyroidectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Fresh osteochondral allografts in the knee: comparison of primary transplantation versus transplantation after failure of previous subchondral marrow stimulation.

    Science.gov (United States)

    Gracitelli, Guilherme C; Meric, Gokhan; Briggs, Dustin T; Pulido, Pamela A; McCauley, Julie C; Belloti, João Carlos; Bugbee, William D

    2015-04-01

    In most treatment algorithms, osteochondral allograft (OCA) transplantation is regarded as an alternative salvage procedure when other, previous reparative treatments have failed. To compare the outcomes of a retrospective matched-pair cohort of (1) primary OCA transplantation and (2) OCA transplantation after failure of previous subchondral marrow stimulation. Cohort study; Level of evidence, 3. An OCA database was used to identify 46 knees that had OCA transplantation performed as a primary treatment (group 1) and 46 knees that underwent OCA transplantation after failure of previous subchondral marrow stimulation (group 2). All patients had a minimum of 2 years' follow-up. Patients in each group were matched for age (±5 years), diagnosis (osteochondral lesion, degenerative chondral lesion, traumatic chondral injury), and graft size (small, 10 cm2). The groups had similar body mass indexes, sex distributions, and graft locations (femoral condyle, patella, and trochlea. The number and type of further surgeries after the OCA transplantation were assessed; failure was defined as any reoperation resulting in removal of the graft. Functional outcomes were evaluated by use of the modified Merle d'Aubigné-Postel (18-point) scale, International Knee Documentation Committee (IKDC) subjective knee evaluation form, Knee injury and Osteoarthritis Outcomes Score (KOOS), and the Knee Society function (KS-F) scale. Patient satisfaction, according to a 5-point scale from "extremely satisfied" to "dissatisfied," was recorded at the latest follow-up. Eleven of 46 knees (24%) in group 1 had reoperations, compared with 20 of 46 knees (44%) in group 2 (P = .04). The OCA was classified as a failure in 5 knees (11%) in group 1 and 7 knees (15%) in group 2 (P = .53). At 10 years of follow-up, survivorship of the graft was 87.4% and 86% in groups 1 and 2, respectively. Both groups showed improvement in pain and function on all subjective scores from preoperatively to the latest follow

  11. Omega-3 Polyunsaturated Fatty Acid Supplementation to Prevent Arteriovenous Fistula and Graft Failure: A Systematic Review and Meta-analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Viecelli, Andrea K; Irish, Ashley B; Polkinghorne, Kevan R; Hawley, Carmel M; Johnson, David W; Mori, Trevor A; Pascoe, Elaine M; Strippoli, Giovanni F M; Lok, Charmaine E; Palmer, Suetonia C

    2018-01-27

    Arteriovenous access failure frequently occurs in people on hemodialysis and is associated with morbidity, mortality and large healthcare expenditures. Omega-3 polyunsaturated fatty acids (omega-3 PUFA) may improve access outcomes via pleiotropic effects on access maturation and function, but may cause bleeding complications. Systematic review with meta-analysis. Adults requiring hemodialysis via arteriovenous fistula or graft. Trials evaluating omega-3 PUFA for arteriovenous access outcomes identified by searches in CENTRAL, MEDLINE, and Embase to 24 January 2017. Omega-3 PUFA. Primary patency loss, dialysis suitability failure, access abandonment, interventions to maintain patency or assist maturation, bleeding, gastrointestinal side-effects, all-cause and cardiovascular mortality, hospitalization, and treatment adherence. Treatment effects were summarized as relative risks (RR) and 95% confidence intervals (CI). Evidence was assessed using GRADE. Five eligible trials (833 participants) with a median follow-up of 12 months compared peri-operative omega-3 PUFA supplementation with placebo. One trial (n=567) evaluated treatment for fistulae and four (n=266) for grafts. Omega-3 PUFA supplementation prevented primary patency loss with moderate certainty (761 participants, RR 0.81, CI 0.68-0.98). Low quality evidence suggested, that omega-3 PUFA may have had little or no effect on dialysis suitability failure (536 participants, RR 0.95, CI 0.73-1.23), access abandonment (732 participants, RR 0.78, CI 0.59-1.03), need for interventions (732 participants, RR 0.82, CI 0.64-1.04), or all-cause mortality (799 participants, RR 0.99, CI 0.51-1.92). Bleeding risk (793 participants, RR 1.40, CI 0.78-2.49) or gastrointestinal side-effects (816 participants, RR 1.22, CI 0.64-2.34) from treatment were uncertain. There was no evidence of different treatment effects for grafts and fistulae. Small number and methodological limitations of included trials. Omega-3 PUFA supplementation

  12. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  13. Graft failure following bone marrow transplantation for severe aplastic anemia risk factors and treatment results

    NARCIS (Netherlands)

    Champlin, R.E.; Horowitz, M.M.; Bekkum, D.W. van; Camitta, B.M. Elfenbein, G.E.; Gale, R.P.; Gluckman, E.; Good, R.A.; Rimm, A.A. Rozman, C.; Speck, B. Bortin, M.M

    1989-01-01

    Graft failure was analyzed in 625 patients receiving allogeneic bone marrow transplants from HLA-identical sibling donors as treatment for severe aplastic anemia. Sixty-eight (11%) had no or only transient engraftment. Second bone marrow transplants were successful in achieving extended survival in

  14. Use of Renal Replacement Therapy May Influence Graft Outcomes following Liver Transplantation for Acute Liver Failure: A Propensity-Score Matched Population-Based Retrospective Cohort Study.

    Science.gov (United States)

    Knight, Stephen R; Oniscu, Gabriel C; Devey, Luke; Simpson, Kenneth J; Wigmore, Stephen J; Harrison, Ewen M

    2016-01-01

    Acute kidney injury is associated with a poor prognosis in acute liver failure but little is known of outcomes in patients undergoing transplantation for acute liver failure who require renal replacement therapy. A retrospective analysis of the United Kingdom Transplant Registry was performed (1 January 2001-31 December 2011) with patient and graft survival determined using Kaplan-Meier methods. Cox proportional hazards models were used together with propensity-score based full matching on renal replacement therapy use. Three-year patient and graft survival for patients receiving renal replacement therapy were 77.7% and 72.6% compared with 85.1% and 79.4% for those not requiring renal replacement therapy (Prenal replacement therapy was a predictor of both patient death (hazard ratio (HR) 1.59, 95% CI 1.01-2.50, P = 0.044) but not graft loss (HR 1.39, 95% CI 0.92-2.10, P = 0.114). In groups fully matched on baseline covariates, those not receiving renal replacement therapy with a serum creatinine greater than 175 μmol/L had a significantly worse risk of graft failure than those receiving renal replacement therapy. In patients being transplanted for acute liver failure, use of renal replacement therapy is a strong predictor of patient death and graft loss. Those not receiving renal replacement therapy with an elevated serum creatinine may be at greater risk of early graft failure than those receiving renal replacement therapy. A low threshold for instituting renal replacement therapy may therefore be beneficial.

  15. H-Y Antigen Incompatibility Not Associated with Adverse Immunologic Graft Outcomes: Deceased Donor Pair Analysis of the OPTN Database

    Directory of Open Access Journals (Sweden)

    Douglas Scott Keith

    2011-01-01

    Full Text Available Background. H-Y antigen incompatibility adversely impacts bone marrow transplants however, the relevance of these antigens in kidney transplantation is uncertain. Three previous retrospective studies of kidney transplant databases have produced conflicting results. Methods. This study analyzed the Organ Procurement and Transplantation Network database between 1997 and 2009 using male deceased donor kidney transplant pairs in which the recipient genders were discordant. Death censored graft survival at six months, five, and ten years, treated acute rejection at six months and one year, and rates of graft failure by cause were the primary endpoints analyzed. Results. Death censored graft survival at six months was significantly worse for female recipients. Analysis of the causes of graft failure at six months revealed that the difference in death censored graft survival was due primarily to nonimmunologic graft failures. The adjusted and unadjusted death censored graft survivals at five and ten years were similar between the two genders as were the rates of immunologic graft failure. No difference in the rates of treated acute rejection at six months and one year was seen between the two genders. Conclusions. Male donor to female recipient discordance had no discernable effect on immunologically mediated kidney graft outcomes in the era of modern immunosuppression.

  16. Algorithm for Primary Full-thickness Skin Grafting in Pediatric Hand Burns

    Directory of Open Access Journals (Sweden)

    Yang Seo Park

    2012-09-01

    Full Text Available Background Pediatric hand burns are a difficult problem because they lead to serious handdeformities with functional impairment due to rapid growth during childhood. Therefore,adequate management is required beginning in the acute stage. Our study aims to establishsurgical guidelines for a primary full-thickness skin graft (FTSG in pediatric hand burns, basedon long-term observation periods and existing studies.Methods From January 2000 to May 2011, 210 patients underwent primary FTSG. Weretrospectively studied the clinical course and treatment outcomes based on the patients’medical records. The patients’ demographics, age, sex, injury site of the fingers, presence ofweb space involvement, the incidence of postoperative late deformities, and the duration ofrevision were critically analyzed.Results The mean age of the patients was 24.4 months (range, 8 to 94 months, consisting of141 males and 69 females. The overall observation period was 6.9 years (range, 1 to 11 yearson average. At the time of the burn, 56 cases were to a single finger, 73 to two fingers, 45 tothree fingers, and 22 to more than three. Among these cases, 70 were burns that included aweb space (33.3%. During the observation, 25 cases underwent corrective operations withan average period of 40.6 months.Conclusions In the volar area, primary full-thickness skin grafting can be a good indicationfor an isolated injured finger, excluding the web spaces, and injuries of less than three fingersincluding the web spaces. Also, in the dorsal area, full-thickness skin grafting can be a goodindication. However, if the donor site is insufficient and the wound is large, split-thicknessskin grafting can be considered.

  17. Selective Grafting of Primary Amines onto Carbon Nanotubes via Free-Radical Treatment in Microwave Plasma Post-Discharge

    Directory of Open Access Journals (Sweden)

    Philippe Dubois

    2012-01-01

    Full Text Available A novel strategy to graft functional groups at the surface of carbon nanotubes (CNTs is discussed. Aiming at grafting nitrogen containing groups, and more specifically primary amine covalent functionalization, CNTs were exposed under atomic nitrogen flow arising from an Ar + N2 microwave plasma. The primary amine functions were identified and quantified through chemical derivatization with 4-(trifluoromethylbenzaldehyde and characterized through X-ray photoelectron spectroscopy. The increase of the selectivity in the primary amines grafting onto CNTs, up to 66.7% for treatment of CNT powder, was performed via the reduction of post-treatment oxygen contamination and the addition of hydrogen in the experimental set-up, more particularly in the plasma post-discharge chamber. The analyses of nitrogenated and primary amine functions grafting on the CNT surface suggest that atomic nitrogen (N• and reduced nitrogen species (NH• and NH2• react preferentially with defect sites of CNTs and, then, only atomic nitrogen continues to react on the CNT surface, creating defects.

  18. A different management of saphenous vein graft failure related to cardiac tamponade following coronary surgery

    Directory of Open Access Journals (Sweden)

    Hamit Serdar Başbuğ

    2016-03-01

    Full Text Available Cardiac tamponade is a state of constriction of the heart with an excessive fluid or hematoma resulted from various conditions. Postoperative tamponade can occur after coronary bypass surgery. Despite it is uncommon, its results may have a high risk of mortality and morbidity. Acute postoperative cardiac tamponade reveals a vast spectrum of symptoms. Moreover, a compression over the saphenous vein graft is the worst complication that should be managed without delay. We report a rare case of saphenous vein graft failure due to the cardiac tamponade following a coronary surgery and its management with a practical measure.

  19. Algorithm for Primary Full-thickness Skin Grafting in Pediatric Hand Burns

    Directory of Open Access Journals (Sweden)

    Yang Seo Park

    2012-09-01

    Full Text Available BackgroundPediatric hand burns are a difficult problem because they lead to serious hand deformities with functional impairment due to rapid growth during childhood. Therefore, adequate management is required beginning in the acute stage. Our study aims to establish surgical guidelines for a primary full-thickness skin graft (FTSG in pediatric hand burns, based on long-term observation periods and existing studies.MethodsFrom January 2000 to May 2011, 210 patients underwent primary FTSG. We retrospectively studied the clinical course and treatment outcomes based on the patients' medical records. The patients' demographics, age, sex, injury site of the fingers, presence of web space involvement, the incidence of postoperative late deformities, and the duration of revision were critically analyzed.ResultsThe mean age of the patients was 24.4 months (range, 8 to 94 months, consisting of 141 males and 69 females. The overall observation period was 6.9 years (range, 1 to 11 years on average. At the time of the burn, 56 cases were to a single finger, 73 to two fingers, 45 to three fingers, and 22 to more than three. Among these cases, 70 were burns that included a web space (33.3%. During the observation, 25 cases underwent corrective operations with an average period of 40.6 months.ConclusionsIn the volar area, primary full-thickness skin grafting can be a good indication for an isolated injured finger, excluding the web spaces, and injuries of less than three fingers including the web spaces. Also, in the dorsal area, full-thickness skin grafting can be a good indication. However, if the donor site is insufficient and the wound is large, split-thickness skin grafting can be considered.

  20. Neutrophil extracellular traps are pathogenic in primary graft dysfunction after lung transplantation.

    Science.gov (United States)

    Sayah, David M; Mallavia, Beñat; Liu, Fengchun; Ortiz-Muñoz, Guadalupe; Caudrillier, Axelle; DerHovanessian, Ariss; Ross, David J; Lynch, Joseph P; Saggar, Rajan; Ardehali, Abbas; Ware, Lorraine B; Christie, Jason D; Belperio, John A; Looney, Mark R

    2015-02-15

    Primary graft dysfunction (PGD) causes early mortality after lung transplantation and may contribute to late graft failure. No effective treatments exist. The pathogenesis of PGD is unclear, although both neutrophils and activated platelets have been implicated. We hypothesized that neutrophil extracellular traps (NETs) contribute to lung injury in PGD in a platelet-dependent manner. To study NETs in experimental models of PGD and in lung transplant patients. Two experimental murine PGD models were studied: hilar clamp and orthotopic lung transplantation after prolonged cold ischemia (OLT-PCI). NETs were assessed by immunofluorescence microscopy and ELISA. Platelet activation was inhibited with aspirin, and NETs were disrupted with DNaseI. NETs were also measured in bronchoalveolar lavage fluid and plasma from lung transplant patients with and without PGD. NETs were increased after either hilar clamp or OLT-PCI compared with surgical control subjects. Activation and intrapulmonary accumulation of platelets were increased in OLT-PCI, and platelet inhibition reduced NETs and lung injury, and improved oxygenation. Disruption of NETs by intrabronchial administration of DNaseI also reduced lung injury and improved oxygenation. In bronchoalveolar lavage fluid from human lung transplant recipients, NETs were more abundant in patients with PGD. NETs accumulate in the lung in both experimental and clinical PGD. In experimental PGD, NET formation is platelet-dependent, and disruption of NETs with DNaseI reduces lung injury. These data are the first description of a pathogenic role for NETs in solid organ transplantation and suggest that NETs are a promising therapeutic target in PGD.

  1. Corneal graft reversal: Histopathologic report of two cases.

    Science.gov (United States)

    Qahtani, Abdullah A; Alkatan, Hind M

    2014-10-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal.

  2. Early onset hyperuricemia is a prognostic marker for kidney graft failure: Propensity score matching analysis in a Korean multicenter cohort.

    Directory of Open Access Journals (Sweden)

    Miyeun Han

    Full Text Available It remains inconclusive whether hyperuricemia is a true risk factor for kidney graft failure. In the current study, we investigated the association of hyperuricemia and graft outcome. We performed a multi-center cohort study that included 2620 kidney transplant recipients. The patients were classified as either normouricemic or hyperuricemic at 3 months after transplantation. Hyperuricemia was defined as a serum uric acid level ≥ 7.0 mg/dL in males or ≥ 6.0 mg/dL in females or based on the use of urate-lowering medications. The two groups were compared before and after propensity score matching. A total of 657 (25.1% patients were classified as hyperuricemic. The proportion of hyperuricemic patients increased over time, reaching 44.2% of the total cohort at 5 years after transplantation. Estimated glomerular filtration rate and donor type were independently associated with hyperuricemia. Hyperuricemia was associated with graft loss according to multiple Cox regression analysis before propensity score matching (hazard ratio [HR] = 1.56, 95% confidence interval [CI] = 1.14-2.13, P = 0.005 as well as after matching (HR = 1.65, 95% CI = 1.13-2.42, p = 0.010. Cox regression models using time-varying hyperuricemia or marginal structural models adjusted with time-varying eGFR also demonstrated significant hazards of hyperuricemia for graft loss. Cardiovascular events and recipient survival were not associated with hyperuricemia. Overall, hyperuricemia, especially early onset after transplantation, showed an increased risk for graft failure. Further studies are warranted to determine whether lowering serum uric acid levels would be beneficial to graft survival.

  3. The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets.

    Science.gov (United States)

    Jun, Sang Ho; Park, Chang-Joo; Hwang, Suk-Hyun; Lee, Youn Ki; Zhou, Cong; Jang, Hyon-Seok; Ryu, Jae-Jun

    2018-12-01

    This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg ( R  = 0.606, P  = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

  4. Postoperative radiographic evaluation of vascularized fibular grafts

    International Nuclear Information System (INIS)

    Manaster, B.J.; Coleman, D.A.; Bell, D.A.

    1989-01-01

    This paper reports on thirty-five patients with free vascularized fibular grafts examined postoperatively with plain radiography. Early graft incorporation is seen as a fuzziness of the cortex at the site of its insertion into the host bone. Causes of failure in grafting for bone defects include graft fracture, hardware failure, and infection. A high percentage of complications or at least delayed unions occurred when vascularized fibular grafts were used to fill defects in the lower extremity. Conversely, upper extremity defects bridged by vascularized grafts heal quickly and hypertrophy. Vascularized grafts placed in the femoral head and neck for a vascular necrosis incorporate early on their superior aspect. The osseous tunnel in which they are placed is normally wider than the graft and often becomes sclerotic; this appearance does not represent nonunion

  5. Investigating Clinical Failure of Bone Grafting through a Window at the Femoral Head Neck Junction Surgery for the Treatment of Osteonecrosis of the Femoral Head.

    Directory of Open Access Journals (Sweden)

    Wei Zuo

    Full Text Available This study aimed to analyze the clinical factors related to the failure of bone grafting through a window at the femoral head-neck junction.In total, 119 patients (158 hips underwent bone grafting for treatment of avascular necrosis of the femoral head. The patients were classified by their ARCO staging and CJFH classification. All patients were clinically and radiographically followed up every three months during the first year and every six months in the following year. The clinical follow-up comprised determination of pre- and postoperative Harris hip scores, while serial AP, frog lateral radiographs, and CT scan were used for the radiographic follow-up.The clinical failure of bone grafting was observed in 40 patients. The clinical failure rates in patients belonging to ARCO stage II period, IIIa, and III (b + c were 25.9%, 16.2%, and 61.5%, respectively, while those in patients belonging to (C + M + L1 type and L2, L3 type disease groups were 1.7%, 38.9%, and 39%, respectively. The clinical failure rates in patients aged below 40 and those aged 40 and over were 20.5% and 39.0%, respectively (all P < 0.05.Disease type, disease stage, and patient age are risk factors for failure of bone graft surgery. Patients belonging to ARCO stage II and IIIa showed a good overall response rate, while patients belonging to ARCO stage IIIb and IIIc and those with necrotic lesions involving the lateral pillar (L2 and L3 type showed high surgical failure rates.

  6. Corneal graft reversal: Histopathologic report of two cases

    OpenAIRE

    Qahtani, Abdullah A.; Alkatan, Hind M.

    2014-01-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for faile...

  7. Comparison of the predictive performance of eGFR formulae for mortality and graft failure in renal transplant recipients.

    LENUS (Irish Health Repository)

    He, Xiang

    2009-02-15

    To date, efforts have focused on assessing estimated glomerular filtration rate (eGFR) formulae against measured GFR. However, a more appropriate clinical gold standard is one conveying a defined clinical disadvantage. In renal transplantation, these measures are mortality and graft failure.

  8. Variations in living donor graft rates by dialysis clinic: effect on outcome and cost of chronic renal failure therapy.

    Science.gov (United States)

    Baltzan, M A; Ahmed, S; Baltzan, R B; Marshall, R P; Thoma, E L; Nicol, M F

    1997-06-01

    Examination of nephrology practice variations in living donor renal grafts to determine their influence on organ supply, quality, and cost of chronic renal failure therapy. Saskatchewan chronic dialysis, cadaveric, and living donor renal grafts in 1983-1994 inclusive. Saskatchewan has three dialysis (I, II, III) and one transplant clinic. In the period the renal graft incidences/million population by these dialysis clinics by organ source were; Cadaveric: 23.1, 23.2, 21.1 (p = ns). Living: 5.4, 21.7, 8.3 (I or III vs II p actuarial patient survival is 92% and B 44%. Series A ten-year actuarial graft survival (including regrafts) is 77% and B 39%. Rehabilitation rate in patients with functioning grafts is 88.5%. Province-wide extension of the Clinic II living-donor graft rate in 1983-1994 would have produced 160 more renal grafts or 59% of those receiving chronic dialysis in 1994. The annual maintenance for a graft with the initial grafting cost taken over five years was $10,825 and the dialysis cost $40,100. (1) nephrology practice variations caused a 2.5-4.0-fold difference in living donor renal graft rates, indicating patient education by the attending nephrologist influences the living donor transplantation rate, (2) with such education the combined living donor and the cadaveric organ supply virtually meets graft demand, (3) living donor renal grafts yield a better quantity and quality of life and better cost control than dialysis with their annual cost being one-quarter that for dialysis.

  9. 49 CFR 214.529 - In-service failure of primary braking system.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false In-service failure of primary braking system. 214... Maintenance Machines and Hi-Rail Vehicles § 214.529 In-service failure of primary braking system. (a) In the event of a total in-service failure of its primary braking system, an on-track roadway maintenance...

  10. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  11. Ibrutinib for chronic graft-versus-host disease after failure of prior therapy.

    Science.gov (United States)

    Miklos, David; Cutler, Corey S; Arora, Mukta; Waller, Edmund K; Jagasia, Madan; Pusic, Iskra; Flowers, Mary E; Logan, Aaron C; Nakamura, Ryotaro; Blazar, Bruce R; Li, Yunfeng; Chang, Stephen; Lal, Indu; Dubovsky, Jason; James, Danelle F; Styles, Lori; Jaglowski, Samantha

    2017-11-23

    Chronic graft-versus-host disease (cGVHD) is a serious complication of allogeneic stem cell transplantation with few effective options available after failure of corticosteroids. B and T cells play a role in the pathophysiology of cGVHD. Ibrutinib inhibits Bruton tyrosine kinase in B cells and interleukin-2-inducible T-cell kinase in T cells. In preclinical models, ibrutinib reduced severity of cGVHD. This multicenter, open-label study evaluated the safety and efficacy of ibrutinib in patients with active cGVHD with inadequate response to corticosteroid-containing therapies. Forty-two patients who had failed 1 to 3 prior treatments received ibrutinib (420 mg) daily until cGVHD progression. The primary efficacy end point was cGVHD response based on 2005 National Institutes of Health criteria. At a median follow-up of 13.9 months, best overall response was 67%; 71% of responders showed a sustained response for ≥20 weeks. Responses were observed across involved organs evaluated. Most patients with multiple cGVHD organ involvement had a multiorgan response. Median corticosteroid dose in responders decreased from 0.29 mg/kg per day at baseline to 0.12 mg/kg per day at week 49; 5 responders discontinued corticosteroids. The most common adverse events were fatigue, diarrhea, muscle spasms, nausea, and bruising. Plasma levels of soluble factors associated with inflammation, fibrosis, and cGVHD significantly decreased over time with ibrutinib. Ibrutinib resulted in clinically meaningful responses with acceptable safety in patients with ≥1 prior treatments for cGVHD. Based on these results, ibrutinib was approved in the United States for treatment of adult patients with cGVHD after failure of 1 or more lines of systemic therapy. This trial was registered at www.clinicaltrials.gov as #NCT02195869. © 2017 by The American Society of Hematology.

  12. Retransplantation in 7,290 primary transplant patients: a 10-year multi-institutional study.

    Science.gov (United States)

    Radovancevic, Branislav; McGiffin, David C; Kobashigawa, Jon A; Cintron, Guillermo B; Mullen, G Martin; Pitts, Douglas E; O'Donnell, Jacqueline; Thomas, Cindi; Bourge, Robert C; Naftel, David C

    2003-08-01

    Cardiac retransplantation is a controversial procedure due to the disparity between donor heart demand and supply. Of 7,290 patients undergoing primary cardiac transplantation between January 1990 and December 1999 at 42 institutions contributing to the Cardiac Transplant Research Database (CTRD), 106 patients later underwent a second and 1 patient a third cardiac transplant procedure. The actuarial freedom from retransplantation was 99.2% and 96.8% at 1 and 10 years, respectively. Reasons for retransplantation included early graft failure (n = 34), acute cardiac rejection (n = 15), coronary allograft vasculopathy (CAV, n = 39), non-specific graft failure (n = 7), and miscellaneous (n = 10). The only risk factor associated with retransplantation was younger age, reflecting the policy of preferential retransplantation of younger patients. Survival after retransplantation was inferior to that after primary transplantation (56% and 38% at 1 and 5 years, respectively). Risk factors associated with death after retransplantation included retransplantation for acute rejection (p = 0.0005), retransplantation for early graft failure (p = 0.03), and use of a female donor (p = 0.005). Survival after retransplantation for acute rejection was poorest (32% and 8% at 1 and 5 years, respectively) followed by retransplantation for early graft failure (50% and 39% at 1 and 5 years, respectively). Survival after retransplantation for CAV has steadily improved with successive eras. The results of retransplantation for acute rejection and early graft failure are poor enough to suggest that this option is not advisable. However, retransplantation for CAV is currently associated with satisfactory survival and should continue to be offered to selected patients.

  13. Management of long segment anterior urethral stricture (≥ 8cm using buccal mucosal (BM graft and penile skin (PS flap: outcome and predictors of failure

    Directory of Open Access Journals (Sweden)

    Gamal A. Alsagheer

    Full Text Available ABSTRACT Purpose To evaluate the surgical outcome and predictors of failure of substitution urethroplasty using either dorsal onlay buccal mucosal (BM graft or ventral onlay penile skin flap (PS for anterior urethral stricture ≥ 8cm. Patients and methods Between March 2010 and January 2016, 50 patients with anterior urethral stricture ≥ 8 cm were treated at our hospital. The surgical outcome and success rate were assessed. The predictors of failure were analyzed using multivariate analysis. Failure was considered when subsequent urethrotomy or urethroplasty were needed. Results Dorsal onlay BM graft was carried out in 24 patients, while PS urethroplasty in 26 patients. There was no significant difference between both groups regarding patients demographics, stricture characteristics or follow-up period. One case in the BM group was lost during follow-up. Stricture recurrence was detected in 7 (30.4% patients out of BM group while in 6 (23.1% patients out of PS group (p value= 0.5. No significant differences between both groups regarding overall early and late complications were observed. Occurrence of early complications and the stricture length were the only predictors of failure in univariate analysis, while in multivariate analysis the occurrence of early complications was only significant. Conclusion On short-term follow-up, both dorsal onlay BM graft and ventral onlay PS flap urethroplasty have similar success rates. However, BM graft has a potential advantage to reduce operative time and is also technically easier. The surgeon should avoid early local complications as they represent a higher risk for failure.

  14. Primary Graft Dysfunction and Long-Term Outcomes Following Lung Transplantation

    OpenAIRE

    DerHovanessian, Ariss

    2012-01-01

    Background: Primary graft dysfunction (PGD) is an early complication of lung transplantation associated with poor early outcomes, however less is known about its prolonged effects on morbidity and mortality. We hypothesized that PGD is associated with long-term mortality and chronic rejection in the form of bronchiolitis obliterans syndrome. Methods: A retrospective study of 279 adult lung transplant recipients between 2000 and 2007 was performed. PGD grade was determined both immediately ...

  15. The vascularised fibular graft for limb salvage after bone tumour surgery A MULTICENTRE STUDY

    NARCIS (Netherlands)

    Hilven, P. H.; Bayliss, L.; Cosker, T.; Dijkstra, P. D. S.; Jutte, P. C.; Lahoda, L. U.; Schaap, G. R.; Bramer, J. A. M.; van Drunen, G. K.; Strackee, S. D.; van Vooren, J.; Gibbons, M.; Giele, H.; van de Sande, M. A. J.

    2015-01-01

    Vascularised fibular grafts (VFGs) are a valuable surgical technique in limb salvage after resection of a tumour. The primary objective of this multicentre study was to assess the risk factors for failure and complications for using a VFG after resection of a tumour. The study involved 74

  16. Comparison of mode of failure between primary and revision total knee arthroplasties.

    Science.gov (United States)

    Liang, H; Bae, J K; Park, C H; Kim, K I; Bae, D K; Song, S J

    2018-04-01

    Cognizance of common reasons for failure in primary and revision TKA, together with their time course, facilitates prevention. However, there have been few reports specifically comparing modes of failure for primary vs. revision TKA using a single prosthesis. The goal of the study was to compare the survival rates, modes of failure, and time periods associated with each mode of failure, of primary vs. revision TKA. The survival rates, modes of failure, time period for each mode of failure, and risk factors would differ between primary and revision TKA. Data from a consecutive cohort comprising 1606 knees (1174 patients) of primary TKA patients, and 258 knees (224 patients) of revision TKA patients, in all of whom surgery involved a P.F.C ® prosthesis (Depuy, Johnson & Johnson, Warsaw, IN), was retrospectively reviewed. The mean follow-up periods of primary and revision TKAs were 9.2 and 9.8 years, respectively. The average 10- and 15-year survival rates for primary TKA were 96.7% (CI 95%,±0.7%) and 85.4% (CI 95%,±2.0%), and for revision TKA 91.4% (CI 95%,±2.5%) and 80.5% (CI 95%,±4.5%). Common modes of failure included polyethylene wear, loosening, and infection. The most common mode of failure was polyethylene wear in primary TKA, and infection in revision TKA. The mean periods (i.e., latencies) of polyethylene wear and loosening did not differ between primary and revision TKAs, but the mean period of infection was significantly longer for revision TKA (1.2 vs. 4.8 years, P=0.003). Survival rates decreased with time, particularly more than 10 years post-surgery, for both primary and revision TKAs. Continuous efforts are required to prevent and detect the various modes of failure during long-term follow-up. Greater attention is necessary to detect late infection-induced failure following revision TKA. Case-control study, Level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Primary renal graft thrombosis

    NARCIS (Netherlands)

    Bakir, N; Sluiter, WJ; Ploeg, RJ; van Son, WJ; Tegzess, Adam

    Background. Renal allograft thrombosis is a serious complication of kidney transplantation that ultimately leads to graft loss. Its association with acute and hyperacute rejection is well documented; however, in a large proportion of patients the precise cause remains obscure. The exact incidence

  18. Microarray Meta-Analysis Identifies Acute Lung Injury Biomarkers in Donor Lungs That Predict Development of Primary Graft Failure in Recipients

    Science.gov (United States)

    Haitsma, Jack J.; Furmli, Suleiman; Masoom, Hussain; Liu, Mingyao; Imai, Yumiko; Slutsky, Arthur S.; Beyene, Joseph; Greenwood, Celia M. T.; dos Santos, Claudia

    2012-01-01

    Objectives To perform a meta-analysis of gene expression microarray data from animal studies of lung injury, and to identify an injury-specific gene expression signature capable of predicting the development of lung injury in humans. Methods We performed a microarray meta-analysis using 77 microarray chips across six platforms, two species and different animal lung injury models exposed to lung injury with or/and without mechanical ventilation. Individual gene chips were classified and grouped based on the strategy used to induce lung injury. Effect size (change in gene expression) was calculated between non-injurious and injurious conditions comparing two main strategies to pool chips: (1) one-hit and (2) two-hit lung injury models. A random effects model was used to integrate individual effect sizes calculated from each experiment. Classification models were built using the gene expression signatures generated by the meta-analysis to predict the development of lung injury in human lung transplant recipients. Results Two injury-specific lists of differentially expressed genes generated from our meta-analysis of lung injury models were validated using external data sets and prospective data from animal models of ventilator-induced lung injury (VILI). Pathway analysis of gene sets revealed that both new and previously implicated VILI-related pathways are enriched with differentially regulated genes. Classification model based on gene expression signatures identified in animal models of lung injury predicted development of primary graft failure (PGF) in lung transplant recipients with larger than 80% accuracy based upon injury profiles from transplant donors. We also found that better classifier performance can be achieved by using meta-analysis to identify differentially-expressed genes than using single study-based differential analysis. Conclusion Taken together, our data suggests that microarray analysis of gene expression data allows for the detection of

  19. Prevention of primary vascular graft infection with silver-coated polyester graft in a porcine model

    DEFF Research Database (Denmark)

    Gao, H; Sandermann, J; Prag, J

    2010-01-01

    To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model.......To evaluate the efficacy of a silver-coated vascular polyester graft in the prevention of graft infection after inoculation with Staphylococcus aureus in a porcine model....

  20. Primary testicular failure in Klinefelter's syndrome

    DEFF Research Database (Denmark)

    Aksglaede, Lise; Andersson, Anna-Maria; Jørgensen, Niels

    2007-01-01

    The diagnosis of androgen deficiency is based on clinical features and confirmatory low serum testosterone levels. In early primary testicular failure, a rise in serum LH levels suggests inadequate androgen action for the individual's physiological requirements despite a serum testosterone level...

  1. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  2. Associations between inadequate knee function detected by KOOS and prospective graft failure in an anterior cruciate ligament-reconstructed knee.

    Science.gov (United States)

    Granan, Lars-Petter; Baste, Valborg; Engebretsen, Lars; Inacio, Maria C S

    2015-04-01

    First, to evaluate whether the 2 year post-operative Knee injury and Osteoarthritis Outcome Score (KOOS) in primary anterior cruciate ligament reconstructions (ACLRs) was significantly different between patients that did not go on to have a subsequent revision after the 2 year post-operative control and the ones that did. Second, to test whether the "clinically failure" value of KOOS quality of life (QoL) < 44 was indicative of a clinically relevant difference in the risk of subsequent revision ACLR. ACLRs reported to the Norwegian Knee Ligament Registry between June 2004 and December 2009. 5,517 primary ACLRs with at least 2-year follow-up with KOOS QoL before revision surgery. There were clinically significant differences, adjusted and unadjusted, in both the KOOS Sport and Recreation and QoL subscales in patients with a later revision surgery compared to those that did not have a revision surgery. In adjusted models, the risk of later ACLR revision was 3.7 (95 % CI 2.2-6.0) higher in patients with a 2-year KOOS QoL < 44 compared to patients with a KOOS QoL ≥ 44. For every 10-point reduction in the KOOS QoL, a 33.6 % (95 % CI 21.2-47.5 %) higher risk for later ACLR revision was observed. This study reveals an association between inadequate knee function, as measured by KOOS, and a prospective ACL-reconstructed graft failure. Prognostic study (prospective cohort study), Level II.

  3. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  4. A multilayered polyurethane foam technique for skin graft immobilization.

    Science.gov (United States)

    Nakamura, Motoki; Ito, Erika; Kato, Hiroshi; Watanabe, Shoichi; Morita, Akimichi

    2012-02-01

    Several techniques are applicable for skin graft immobilization. Although the sponge dressing is a popular technique, pressure failure near the center of the graft is a weakness of the technique that can result in engraftment failure. To evaluate the efficacy of a new skin graft immobilization technique using multilayered polyurethane foam in vivo and in vitro. Twenty-six patients underwent a full-thickness skin graft. Multiple layers of a hydrocellular polyurethane foam dressing were used for skin graft immobilization. In addition, we created an in vitro skin graft model that allowed us to estimate immobilization pressure at the center and edges of skin grafts of various sizes. Overall mean graft survival was 88.9%. In the head and neck region (19 patients), mean graft survival was 93.6%. Based on the in vitro outcomes, this technique supplies effective pressure (skin graft. This multilayered polyurethane foam dressing is simple, safe, and effective for skin graft immobilization. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  5. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  6. A Prospective Study to Compare the Functional and Aesthetic Outcomes with and without Primary Bone Grafting in Facial Fractures

    Directory of Open Access Journals (Sweden)

    Narayanamurthy Sundaramurthy

    2017-10-01

    Full Text Available Introduction: Open Reduction and Internal Fixation (ORIF has been the gold standard in treatment of facial fractures. Bone grafts have been used to correct bone defects in face. Many studies assessing outcomes of ORIF and primary bone grafting separately have been published in literature. Aim: A prospective study to compare the functional and aesthetic outcomes with and without primary bone grafting in facial fractures. Materials and Methods: Thirty patients, admitted between January 2012 and December 2013, were divided into two groups. Group 1 patients underwent ORIF with primary bone grafting and in group 2, only ORIF was done. Clinical and functional, photographic and radiological assessments were done after one month and three months. Results: Mean value of vertical dystopia in groups 1 and 2 after three months postoperatively were 1.25mm and 0.67mm. Mean value of enophthalmos in groups 1 and 2 after three months postoperatively were 0.5mm and 1mm. Thus, vertical dystopia was corrected better without bone grafts and enophthalmos corrected better with bone grafts. Photographic assessment revealed no statistical difference between the two groups. Postoperatively, in upper face fractures, both groups had similar number of patients in grades 1 and 2. Only one patient from group 2 of midface fractures ended up with grade 3 asymmetry. Radiologically, in upper face fractures, group 2 had more mean projection, height and breadth deficits (1.28mm, 2.57mm and 2.42mm when compared to group 1 (0.67mm, 1.50mm and 0.50mm. The mean projection and height deficits were statistically better in group 1. In midface fractures, mean zygomatic complex projection and height deficits were more in group 2 (1.88mm and 0.63mm than group 1 (0.78mm and 0.44mm. The mean zygomatic complex projection was statistically better in group1. Postoperative complications were lesser with the bone graft group. Conclusion: Judicious use of bone grafts in comminuted facial and orbital

  7. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  8. Race and ethnic differences in the epidemiology and risk factors for graft failure after heart transplantation.

    Science.gov (United States)

    Morris, Alanna A; Kalogeropoulos, Andreas P; Zhao, Liping; Owen, Melissa; Raja Laskar, S; David Vega, J; Smith, Andrew; Butler, Javed

    2015-06-01

    Contemporary epidemiology of chronic graft failure (GF) after heart transplantation (HT) is not well described. Moreover, differences in the epidemiology of GF based on race/ethnicity remain poorly understood, despite clear evidence of inferior survival of ethnic minorities after HT. The incidence of GF and the population-attributable risk (PAR) of independent risk factors for GF were assessed in 15,255 patients (76% men; mean age 52 ± 12 years) who underwent primary HT from 2004 to 2012. During a median follow-up of 4.7 years (interquartile range, 2.3-7.1 years), GF developed in 2,926 patients (19.2%), corresponding to an incidence rate of 39.8/1,000 person-years (95% confidence interval, 38.4-41.3). Blacks were more likely to develop GF than Hispanics or whites, with incidence rates of 55.1, 42.2, and 36.5/1,000 person-years, respectively. After multivariable adjustment, black race was associated with a higher risk of GF (hazard ratio, 1.4; 95% confidence interval, 1.2-1.6; p differences in risk factors for GF after HT require further study. Published by Elsevier Inc.

  9. High-Temperature Graphitization Failure of Primary Superheater Tube

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  10. Modes of failures: primary and secondary stresses

    International Nuclear Information System (INIS)

    Roche, R.L.

    1987-07-01

    The paper begins with a reminder that the purpose of stress classification is to ensure suitable margins with respect to failure modes. The distinction between primary stresses and secondary stresses is then examined and a method is given for assessing the degree of elastic follow up in the elastic plastic field. The importance of elastic follow up is then highlighted by an examination of the effect of primary and secondary stresses on crack behavior

  11. Calcification of a Synthetic Renovascular Graft in a Child

    Directory of Open Access Journals (Sweden)

    D.S.T. Chong

    Full Text Available : Introduction: Vascular grafts, especially in paediatric cases, need to be durable. Common failures such as thrombosis are well documented with research efforts directed towards them. However, there are lesser known causes of graft failure, such as graft calcification, and these also require further research focus. Report: A paediatric case is described in which a synthetic renovascular graft, implanted for mid-aortic syndrome, became calcified, necessitating surgical intervention to resolve graft malfunction. Significant calcification in the limb of a bifurcated polyethylene terephthalate graft was found to be the cause of resistant stenosis and refractory hypertension. Histology conducted on the explanted limb showed the presence of multinuclear giant cells, indicating a chronic foreign body response. Discussion: Calcification of vascular grafts is probably more common than previously recognised. Stenosis typically resistant to angioplasty may result in the long term and thus leading to surgical intervention. In young children, this is suboptimal as these grafts need to last throughout adulthood. Explanted prosthetic grafts should be sent to specialist registries such as that in Strasbourg to be optimally assessed so that contributory factors can be identified. Keywords: Renovascular graft, Paediatric, Calcification

  12. Free Diced Cartilage: A New Application of Diced Cartilage Grafts in Primary and Secondary Rhinoplasty.

    Science.gov (United States)

    Kreutzer, Christian; Hoehne, Julius; Gubisch, Wolfgang; Rezaeian, Farid; Haack, Sebastian

    2017-09-01

    Irregularities or deformities of the nasal dorsum after hump reduction account for a significant number of revision rhinoplasties. The authors therefore developed a technique of meticulously dicing and exactly placing free diced cartilage grafts, harvested from septum, rib, or ear cartilage. The cartilage paste is used for smoothening, augmentation, or camouflaging of the nasal dorsum in primary or revision rhinoplasties. A retrospective analysis of multisurgeon consecutive open approach rhinoplasties from January to December of 2014 was conducted at a single center. The authors compared the outcome of three different techniques to augment or cover the nasal dorsum after an observation period of 7 months. In group I, 325 patients with free diced cartilage grafts as the only onlay were included. In group II, consisting of 73 patients, the dorsal onlay was either fascia alone or in combination with free diced cartilage grafts. Forty-eight patients in group III received a dorsal augmentation with the classic diced cartilage in fascia technique. Four hundred forty-six patients undergoing primary and secondary rhinoplasties in which one of the above-mentioned diced cartilage techniques was used were included in the study. The authors found revision rates for dorsal irregularities within the 7-month postoperative observation period of 5.2, 8.2, and 25 percent for groups I, II, and III, respectively. The authors' findings strongly support their clinical experience that the free diced cartilage graft technique presents an effective and easily reproducible method for camouflage and augmentation in aesthetic and reconstructive rhinoplasty.

  13. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  14. [Health literacy in patients with heart failure treated in primary care].

    Science.gov (United States)

    Santesmases-Masana, Rosalia; González-de Paz, Luis; Real, Jordi; Borràs-Santos, Alicia; Sisó-Almirall, Antoni; Navarro-Rubio, Maria Dolors

    2017-01-01

    The level of health literacy is examined, as well as its conditioning factors in patients with heart failure who are seen routinely in a Primary Health Care Area. A multicentre cross-sectional study. 10 Primary care centres from the metropolitan area of Barcelona. Patients diagnosed with heart failure. to have visited the Primary Health Care centre in the last year, being able to arrive at the primary care setting independently, and voluntarily participation. Health Literacy Survey-European Union - Questionnaire (HLS-EU-Q) and Spanish version of the European Heart Failure Self-care Behaviour Scale. An analysis was made of the relationships between health literacy, self-care practices, sociodemographic, and clinical variables using ANOVA test and a multiple linear regression model. The study included 318 patients (51.2% women) with a mean age of 77.9±8.7 years. The index of health literacy of 79.6% (n=253) of the participants indicated problems in understanding healthcare information. Health literacy level was explained by academic level (P<.001), the extent of heart failure (P=.032), self-care, and age (P<.04).The academic level explained 61.6% of the health of literacy (95% bootstrap: 44.58%; 46.75%). In patients with stable heart failure, it is important to consider all factors that help patients to understand the healthcare information. Health literacy explains patient self-care attitude in heart failure. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  15. Detection of imminent vein graft occlusion: what is the optimal surveillance program?

    Science.gov (United States)

    Tinder, Chelsey N; Bandyk, Dennis F

    2009-12-01

    The prediction of infrainguinal vein bypass failure remains an inexact judgment. Patient demographics, technical factors, and vascular laboratory graft surveillance testing are helpful in identifying a high-risk graft cohort. The optimal surveillance program to detect the bypass at risk for imminent occlusion continues to be developed, but required elements are known and include clinical assessment for new or changes in limb ischemia symptoms, measurement of ankle and/or toe systolic pressure, and duplex ultrasound imaging of the bypass graft. Duplex ultrasound assessment of bypass hemodynamics may be the most accurate method to detect imminent vein graft occlusion. The finding of low graft flow during intraoperative assessment or at a scheduled surveillance study predicts failure; and if associated with an occlusive lesion, a graft revision can prolong patency. The most common abnormality producing graft failure is conduit stenosis caused by myointimal hyperplasia; and the majority can be repaired by an endovascular intervention. Frequency of testing to detect the failing bypass should be individualized to the patient, the type of arterial bypass, and prior duplex ultrasound scan findings. The focus of surveillance is on identification of the low-flow arterial bypass and timely repair of detected critical stenosis defined by duplex velocity spectra criteria of a peak systolic velocity 300 cm/s and peak systolic velocity ratio across the stenosis >3.5-correlating with >70% diameter-reducing stenosis. When conducted appropriately, a graft surveillance program should result in an unexpected graft failure rate of <3% per year.

  16. Alveolar graft in the cleft lip and palate patient: Review of 104 cases

    Science.gov (United States)

    Tobella-Camps, María L.; Rivera-Baró, Alejandro

    2014-01-01

    Introduction: Alveolar bone grafting is a vital part of the rehabilitation of cleft patients. The factors that have been most frequently associated with the success of the graft are the age at grafting and the pre-grafting orthodontic treatment. Objectives: 1) Describe the cases of alveolar bone grafts performed at the Maxilofacial Unit of Hospital Sant Joan de Déu, Barcelona (HSJD); and 2) Analyze the success/failure of alveolar grafts and related variables. Material and Methods: Descriptive retrospective study using a sample of 104 patients who underwent a secondary alveolar graft at the Craniofacial Unit of HSJD between 1998 and 2012. The graft was done by the same surgeon in all patients using bone from the iliac crest. Results: 70% of the patients underwent the procedure before the age of 15 (median 14.45 years); 70% of the graft patients underwent pre-graft maxillary expansion. A total of 100 cases were recorded as successful (median age of 14.58 years, 68 underwent pre-graft expansion) and only 4 were recorded as failures (median age of 17.62 years, 3 underwent pre-graft expansion). We did not find statistically significant differences in age at the time of grafting or pre-surgical expansion when comparing the success and failure groups. We found the success rate of the graft to be 96.2%. Conclusions: The number of failures was too small to establish a statistically significant conclusion in our sample regarding the age at grafting and pre-grafting expansion. The use of alveolar bone grafting from the iliac crest has a very high success rate with a very low incidence of complications. Existing controversies regarding secondary bone grafting and the wide range of success rates found in the literature suggest that it is necessary to establish a specific treatment protocol that ensures the success of this procedure. Key words:Alveolar graft, cleft lip and palate, alveolar cleft, alveolar defect. PMID:24880440

  17. Tumor Necrosis Factor Inhibitor Primary Failure Predicts Decreased Ustekinumab Efficacy in Psoriasis Patients.

    Science.gov (United States)

    Sorensen, Eric P; Fanucci, Kristina A; Saraiya, Ami; Volf, Eva; Au, Shiu-chung; Argobi, Yahya; Mansfield, Ryan; Gottlieb, Alice B

    2015-08-01

    Additional studies are needed to examine the efficacy of ustekinumab in psoriasis patients who have previously been exposed to tumor necrosis factor inhibitors (TNFi). To examine the predictive effect of TNFi primary failure and the number of TNFi exposures on the efficacy of ustekinumab in psoriasis treatment. This retrospective study examined 44 psoriasis patients treated at the Tufts Medical Center Department of Dermatology between January 2008 and July 2014. Patients were selected if they were treated with ustekinumab and had ≥ 1 previous TNFi exposure. The following subgroups were compared: patients with vs without a previous TNFi primary failure, and patients with one vs multiple previous TNFi exposures. The efficacy measure used was the previously validated Simple Measure for Assessing Psoriasis Activity (S-MAPA), which is calculated by the product of the body surface area and physician global assessment. The primary outcome was the percentage improvement S-MAPA from course baseline at week 12 of ustekinumab treatment. Secondary outcomes were the psoriasis clearance, primary failure, and secondary failure rates with ustekinumab treatment. Patients with a previous TNFi primary failure had a significantly lower percentage improvement in S-MAPA score at week 12 of ustekinumab treatment compared with patients without TNFi primary failure (36.2% vs 61.1%, P=.027). Multivariate analysis demonstrated that this relationship was independent of patient demographics and medical comorbidities. Patients with multiple TNFi exposures had a non-statistically significant lower percentage S-MAPA improvement at week 12 (40.5% vs 52.9%, P=.294) of ustekinumab treatment compared with patients with a single TNFi exposure. Among psoriasis patients previously exposed to TNFi, a history of a previous TNFi primary failure predicts a decreased response to ustekinumab independent of patient demographics and medical comorbidities.

  18. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Science.gov (United States)

    Chan, Alex H P; Tan, Richard P; Michael, Praveesuda L; Lee, Bob S L; Vanags, Laura Z; Ng, Martin K C; Bursill, Christina A; Wise, Steven G

    2017-01-01

    Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL) we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM) analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP). This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days). We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  19. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Directory of Open Access Journals (Sweden)

    Alex H P Chan

    Full Text Available Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP. This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days. We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  20. Is Bone Grafting Necessary in the Treatment of Malunited Distal Radius Fractures?

    Science.gov (United States)

    Disseldorp, Dominique J. G.; Poeze, Martijn; Hannemann, Pascal F. W.; Brink, Peter R. G.

    2015-01-01

    Background Open wedge osteotomy with bone grafting and plate fixation is the standard procedure for the correction of malunited distal radius fractures. Bone grafts are used to increase structural stability and to enhance new bone formation. However, bone grafts are also associated with donor site morbidity, delayed union at bone–graft interfaces, size mismatch between graft and osteotomy defect, and additional operation time. Purpose The goal of this study was to assess bone healing and secondary fracture displacement in the treatment of malunited distal radius fractures without the use of bone grafting. Methods Between January 1993 and December 2013, 132 corrective osteotomies and plate fixations without bone grafting were performed for malunited distal radius fractures. The minimum follow-up time was 12 months. Primary study outcomes were time to complete bone healing and secondary fracture displacement. Preoperative and postoperative radiographs during follow-up were compared with each other, as well as with radiographs of the uninjured side. Results All 132 osteotomies healed. In two cases (1.5%), healing took more than 4 months, but reinterventions were not necessary. No cases of secondary fracture displacement or hardware failure were observed. Significant improvements in all radiographic parameters were shown after corrective osteotomy and plate fixation. Conclusion This study shows that bone grafts are not required for bone healing and prevention of secondary fracture displacement after corrective osteotomy and plate fixation of malunited distal radius fractures. Level of evidence Therapeutic, level IV, case series with no comparison group PMID:26261748

  1. [Management of heart failure in cardiology and primary care (MICCAP) program: Improving the management of patients with heart failure].

    Science.gov (United States)

    Barrios, V; Escobar, C; Pallares, V; Egocheaga, M I; Lobos, J M; Bover, R; Gómez Doblas, J J; Cosín, J

    2018-03-26

    Despite current treatments, morbidity and mortality of patients with heart failure remain high. The late diagnosis of heart failure, the insufficient heart failure treatment (i.e. not using the appropriate drugs, prescribing lower doses of drugs than recommended, etc.), and a poor coordination between different health care levels, may explain, at least in part, these figures. The Management of Heart Failure in Cardiology and Primary Care (MICCAP) program has been developed with the aim of optimising the integrated management of patients with heart failure between Primary Care and Cardiology, through the improvement of coordination between both health care levels. This includes continuous medical education to reinforce the diagnostic and therapeutic skills of general practitioners in the field of heart failure. The rationale and objectives of the MICCAP program are summarised in this article. Copyright © 2018 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Risk and prevention of graft failure in patients with preexisting donor-specific HLA antibodies undergoing unmanipulated haploidentical SCT.

    Science.gov (United States)

    Yoshihara, S; Maruya, E; Taniguchi, K; Kaida, K; Kato, R; Inoue, T; Fujioka, T; Tamaki, H; Ikegame, K; Okada, M; Soma, T; Hayashi, K; Fujii, N; Onuma, T; Kusunoki, Y; Saji, H; Ogawa, H

    2012-04-01

    A role of donor-specific HLA antibodies (DSA) in graft failure after SCT has been suggested, but the relevance of DSA in unmanipulated haploidentical SCT (haplo-SCT) remains unknown. We prospectively examined HLA antibodies using the Luminex-based single Ag assay for 79 adult patients undergoing unmanipulated haplo-SCT. Among them, 16 (20.2%) were HLA Ab-positive, including five patients with antibodies not corresponding to donor HLA Ags and 11 DSA-positive patients. Of the 11 DSA-positive patients, five received treatments to decrease DSA levels, including two, who received plasma exchange and rituximab, two who received platelet transfusions from healthy-related donors having DSA-corresponding HLA Ags and one who received bortezomib. Platelet transfusion was the most simple and effective treatment option for class I DSA. The cumulative incidence of neutrophil recovery was significantly lower in pretransplant (post-treatment) DSA-positive patients than in DSA-negative patients (61.9 vs 94.4%, P=0.026). Notably, three of five patients with high levels of DSA had graft failure. Donors should be selected on the basis of an evaluation of HLA antibodies. If haplo-SCT from donors with HLA Ags that correspond to high levels of DSA must be performed, then recipients should be treated for DSA to improve the chances of successful donor engraftment.

  3. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  4. The Spectrum of Renal Allograft Failure.

    Directory of Open Access Journals (Sweden)

    Sourabh Chand

    Full Text Available Causes of "true" late kidney allograft failure remain unclear as study selection bias and limited follow-up risk incomplete representation of the spectrum.We evaluated all unselected graft failures from 2008-2014 (n = 171; 0-36 years post-transplantation by contemporary classification of indication biopsies "proximate" to failure, DSA assessment, clinical and biochemical data.The spectrum of graft failure changed markedly depending on the timing of allograft failure. Failures within the first year were most commonly attributed to technical failure, acute rejection (with T-cell mediated rejection [TCMR] dominating antibody-mediated rejection [ABMR]. Failures beyond a year were increasingly dominated by ABMR and 'interstitial fibrosis with tubular atrophy' without rejection, infection or recurrent disease ("IFTA". Cases of IFTA associated with inflammation in non-scarred areas (compared with no inflammation or inflammation solely within scarred regions were more commonly associated with episodes of prior rejection, late rejection and nonadherence, pointing to an alloimmune aetiology. Nonadherence and late rejection were common in ABMR and TCMR, particularly Acute Active ABMR. Acute Active ABMR and nonadherence were associated with younger age, faster functional decline, and less hyalinosis on biopsy. Chronic and Chronic Active ABMR were more commonly associated with Class II DSA. C1q-binding DSA, detected in 33% of ABMR episodes, were associated with shorter time to graft failure. Most non-biopsied patients were DSA-negative (16/21; 76.1%. Finally, twelve losses to recurrent disease were seen (16%.This data from an unselected population identifies IFTA alongside ABMR as a very important cause of true late graft failure, with nonadherence-associated TCMR as a phenomenon in some patients. It highlights clinical and immunological characteristics of ABMR subgroups, and should inform clinical practice and individualised patient care.

  5. Case Series: Keratolimbal Allograft as a Patch Graft for Glaucoma Drainage Devices.

    Science.gov (United States)

    Ahmed, Sarah F; Schmutz, Mason; Mosaed, Sameh

    2017-09-01

    Tube exposure remains one of the most common complications after glaucoma drainage device (GDD) implantation, despite various types of patch grafts available today. We present a 4 patient case series following the effectivity of the keratolimbal allograft (KLAL) as a patch graft for cases of tube exposure. Given its inherent population of stem cells, our hypothesis was that this highly replicative, biological tissue would provide an adequate means of glaucoma tube coverage. The subset of patients chosen for the KLAL patch graft all had a history of abnormally scarred conjunctiva or thin sclera. The aim of utilizing the KLAL patch with its associated donor conjunctival and scleral ring was also to provide additional reinforcement and adequate tube coverage in the setting of compromised native tissue. Four patients comprised of 2 males and 2 females with a minimum postoperative period of 12 months. All GDDs were initially implanted with a limbal-based incision using either Ahmed glaucoma valve or Baerveldt drainage implant. Three of the 4 patients received the KLAL patch graft after tube exposure with scleral patch graft and 1 patient received KLAL as the primary graft during initial tube placement. Two of the 4 eyes experienced tube re-exposure postoperatively at 2 and 3 months, respectively. Both of these cases had a history of prior tube exposure after scleral patch graft and both were tubes placed in the pars plana. Interestingly, the patients with failed grafts were younger with a history of more ocular surgeries as compared with the patients with graft viable eyes. Through our case series, we found that the KLAL utilized as a patch graft over GDD tubes has the potential for favorable outcomes in certain subtypes of eyes. Although further large scale investigation will be necessary to better define the risk factors associated with graft failure, proving the graft's viability is a crucial first step.

  6. Newly diagnosed primary hypothyroidism applicant with massive pericardial effusion and acute renal failure

    Directory of Open Access Journals (Sweden)

    Ates I

    2016-01-01

    Full Text Available Objective. While non-symptomatic pericardial effusion is seen in primary hypothyroidism, massive pericardial effusion is a very rare finding. In the literature, newly diagnosed primary hypothyroidism cases presenting with massive pericardial effusion or acute renal failure are present, but we did not encounter any case first presenting with combination of two signs. In this case report, primary hypothyroidism case that presenting with massive pericardial effusion and acute renal failure will be discussed.

  7. Presenting hydrothorax predicts failure of needle aspiration in primary spontaneous pneumothorax.

    Science.gov (United States)

    Wu, Kwok Kei; Lui, Chun Tat; Ho, Chik Leung; Tsui, Kwok Leung; Fung, Hin Tat

    2016-06-01

    The objective was to evaluate if existence of hydrothorax in initial chest radiograph predicts treatment outcome in patients with primary spontaneous pneumothorax who received needle thoracostomy. This is a retrospective cohort study carried out from January 2011 to August 2014 in 1 public hospital in Hong Kong. All consecutive adult patients aged 18years or above who attended the emergency department with the diagnosis of primary spontaneous pneumothorax with needle aspiration performed as primary treatment were included. Age, smoking status, size of pneumothorax, previous history of pneumothorax, aspirated gas volume and presence of hydropneumothorax in initial radiograph were included in the analysis. The outcome was success or failure of the needle aspiration. Logistic regression was used to identify the predicting factors of failure of needle aspiration. There were a total of 127 patients included. Seventy-three patients (57.5%) were successfully treated with no recurrence upon discharge. Among 54 failure cases, 13 patients (10.2%) failed immediately after procedure as evident by chest radiograph and required second treatment. Forty-one patients (32.3%) failed upon subsequent chest radiographs. Multivariate logistic regression showed factors independently associated with the failure of needle aspiration, which included hydropneumothorax in the initial radiograph (odds ratio [OR]=4.47 [1.56i12.83], P=.005), previous history of pneumothorax (OR=3.92 [1.57-9.79], P=.003), and large size of pneumothorax defined as apex-to-cupola distance ≥5cm (OR=2.75 [1.21-6.26], P=.016). Hydropneumothorax, previous history of pneumothorax, and large size were independent predictors of failure of needle aspiration in treatment of primary spontaneous pneumothorax. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Review on experiments relating to primary containment vessel failure

    International Nuclear Information System (INIS)

    Suzuki, Hiroyuki; Okada, Hidetoshi; Uchida, Sunsuke; Naitoh, Masanori

    2015-01-01

    Experiments regarding failures of primary containment vessels (PCVs) are reviewed and remained issues to be investigated in the future are discussed. Experiments are categorized as those relating to criteria of PCV failures and to FP releases through breaches on PCV boundaries. In the experiments categorized as those relating to criteria of PCV failures, experiments with full-scale, scale models, and compounds used for sealing are surveyed. Experiments relating to an amount of radioactive fission products (FPs) trapped at breaches on PCV boundaries are also reviewed. As remained issues to be investigated in the future, two items are pointed out: Evaluating degradation behavior of PCV boundaries exposed to temperature and pressure from the failure onset criteria to far above them, and evaluating an amount of FPs trapped at breaches on PCV boundaries. (author)

  9. Surgical and Antimicrobial Treatment of Prosthetic Vascular Graft Infections at Different Surgical Sites: A Retrospective Study of Treatment Outcomes

    Science.gov (United States)

    Elzi, Luigia; Gurke, Lorenz; Battegay, Manuel; Widmer, Andreas F.; Weisser, Maja

    2014-01-01

    Objective Little is known about optimal management of prosthetic vascular graft infections, which are a rare but serious complication associated with graft implants. The goal of this study was to compare and characterize these infections with respect to the location of the graft and to identify factors associated with outcome. Methods This was a retrospective study over more than a decade at a tertiary care university hospital that has an established multidisciplinary approach to treating graft infections. Cases of possible prosthetic vascular graft infection were identified from the hospital's infectious diseases database and evaluated against strict diagnostic criteria. Patients were divided into groups according to the locations of their grafts: thoracic-aortic, abdominal-aortic, or peripheral-arterial. Statistical analyses included evaluation of patient and infection characteristics, time to treatment failure, and factors associated specifically with cure rates in aortic graft infections. The primary endpoint was cure at one year after diagnosis of the infection. Results Characterization of graft infections according to the graft location did show that these infections differ in terms of their characteristics and that the prognosis for treatment seems to be influenced by the location of the infection. Cure rate and all-cause mortality at one year were 87.5% and 12.5% in 24 patients with thoracic-aortic graft infections, 37.0% and 55.6% in 27 patients with abdominal-aortic graft infections, and 70.0% and 30.0% in 10 patients with peripheral-arterial graft infections. In uni- and multivariate analysis, the type of surgical intervention used in managing infections (graft retention versus graft replacement) did not affect primary outcome, whereas a rifampicin-based antimicrobial regimen was associated with a higher cure rate. Conclusions We recommend that future prospective studies differentiate prosthetic vascular graft infections according to the location of the

  10. Grafting the alar rim: application as anatomical graft.

    Science.gov (United States)

    Gruber, Ronald P; Fox, Paige; Peled, Anne; Belek, Kyle A

    2014-12-01

    Alar rim contour and alar rim grafts have become essential components of rhinoplasty. Ideally, grafts of the nose should be anatomical in shape. So doing might make grafts of the alar rim more robust. The authors considered doing that by applying the graft as a continuous extension of the lateral crus. Twelve patients (two men and 10 women) constituted the study group (seven primary and five secondary cases). Of those, there were five concave rims, two concave rims with rim retraction, two boxy tips, and three cephalically oriented lateral crura. Surgical technique included the following: (1) an open approach was used; (2) a marginal incision that ignored the caudal margin of the lateral crus (the incision went straight posteriorly to a point 5 to 6 mm from the rim margin) was used; (3) a triangular graft was made to cover the exposed vestibular skin; (4) it was secured end to end to the caudal border of the lateral crus; and (5) the poster end was allowed to sit in a small subcutaneous pocket. Follow-up was 11 to 19 months. All 12 patients exhibited good rims as judged by a blinded panel. Rim retraction was not fully corrected in one patient, but no further treatment was required. One patient did require a secondary small rim graft for residual rim concavity. The concept of grafting the alar rim is strongly supported by the authors' results. The modifications the authors applied by designing the graft to be anatomical in shape has been a technical help.

  11. Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation

    International Nuclear Information System (INIS)

    Liang, Huei-Lung; Pan, Huay-Ben; Lin, Yih-Huie; Chen, Chiung-Yu; Lai, Pin-Hong; Yang, Chien-Fang; Chung, Hsiao-Min; Wu, Tung-Ho; Chou, Kang-Ju

    2006-01-01

    We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patents (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates (±standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69%±9 and 88%±6,41% ±10 and 88%±6, 30%±10 and 77%±10, and 12%±8 and 61%±13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51%±16 and 86%±13 vs 45%±15 and 73%±13 at 6 months, and 25%±15 and 71%±17 vs 23%±17 and 73%±13 at 12 months (ρ = .436 and .224), respectively. Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen

  12. [Heart failure in primary care: Attitudes, knowledge and self-care].

    Science.gov (United States)

    Salvadó-Hernández, Cristina; Cosculluela-Torres, Pilar; Blanes-Monllor, Carmen; Parellada-Esquius, Neus; Méndez-Galeano, Carmen; Maroto-Villanova, Neus; García-Cerdán, Rosa Maria; Núñez-Manrique, M Pilar; Barrio-Ruiz, Carmen; Salvador-González, Betlem

    2018-04-01

    To determine the attitudes, knowledge, and self-care practices in patients with heart failure (HF) in Primary Care, as well as to identify factors associated with better self-care. Cross-sectional and multicentre study. Primary Care. Subjects over 18 years old with HF diagnosis, attended in 10 Primary Health Care Centres in the Metropolitan Area of Barcelona. Self-care was measured using the European Heart Failure Self-Care Behaviour Scale. Sociodemographic and clinical characteristics, tests on attitudes (Self-efficacy Managing Chronic Disease Scale), knowledge (Patient Knowledge Questionnaire), level of autonomy (Barthel), and anxiety and depression screening (Goldberg Test), were also gathered in an interview. A multivariate mixed model stratified by centre was used to analyse the adjusted association of covariates with self-care. A total of 295 subjects (77.6%) agreed to participate, with a mean age of 75.6 years (SD: 11), 56.6% women, and 62% with no primary education. The mean self-care score was 28.65 (SD: 8.22), with 25% of patients scoring lower than 21 points. In the final stratified multivariate model (n=282; R 2 conditional=0.3382), better self-care was associated with higher knowledge (coefficient, 95% confidence interval: -1.37; -1.85 to -0.90), and coronary heart disease diagnosis (-2.41; -4.36: -0.46). Self-care was moderate. The correlation of better self-care with higher knowledge highlights the opportunity to implement strategies to improve self-care, which should consider the characteristics of heart failure patients attended in Primary Care. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  13. The association of donor and recipient age with graft survival in paediatric renal transplant recipients in a European Society for Paediatric Nephrology/European Renal Association-European Dialysis and Transplantation Association Registry study

    DEFF Research Database (Denmark)

    Chesnaye, Nicholas C.; Van Stralen, Karlijn J.; Bonthuis, Marjolein

    2017-01-01

    from the ESPN/ERA-EDTA Registry. The effect of donor and recipient age combinations on 5-year graft-failure risk, stratified by donor source, was estimated using Kaplan-Meier survival curves and Cox regression, while adjusting for sex, primary renal diseases with a high risk of recurrence, pre......Background The impact of donor age in paediatric kidney transplantation is unclear. We therefore examined the association of donor-recipient age combinations with graft survival in children. Methods Data for 4686 first kidney transplantations performed in 13 countries in 1990-2013 were extracted......-emptive transplantation, year of transplantation and country. Results The risk of graft failure in older living donors (50-75 years old) was similar to that of younger living donors {adjusted hazard ratio [aHR] 0.74 [95% confidence interval (CI) 0.38-1.47]}. Deceased donor (DD) age was non-linearly associated with graft...

  14. Identification of subgroups by risk of graft failure after paediatric renal transplantation: application of survival tree models on the ESPN/ERA-EDTA Registry.

    Science.gov (United States)

    Lofaro, Danilo; Jager, Kitty J; Abu-Hanna, Ameen; Groothoff, Jaap W; Arikoski, Pekka; Hoecker, Britta; Roussey-Kesler, Gwenaelle; Spasojević, Brankica; Verrina, Enrico; Schaefer, Franz; van Stralen, Karlijn J

    2016-02-01

    Identification of patient groups by risk of renal graft loss might be helpful for accurate patient counselling and clinical decision-making. Survival tree models are an alternative statistical approach to identify subgroups, offering cut-off points for covariates and an easy-to-interpret representation. Within the European Society of Pediatric Nephrology/European Renal Association-European Dialysis and Transplant Association (ESPN/ERA-EDTA) Registry data we identified paediatric patient groups with specific profiles for 5-year renal graft survival. Two analyses were performed, including (i) parameters known at time of transplantation and (ii) additional clinical measurements obtained early after transplantation. The identified subgroups were added as covariates in two survival models. The prognostic performance of the models was tested and compared with conventional Cox regression analyses. The first analysis included 5275 paediatric renal transplants. The best 5-year graft survival (90.4%) was found among patients who received a renal graft as a pre-emptive transplantation or after short-term dialysis (2.2 years). The Cox model including both pre-transplant factors and tree subgroups had a significantly better predictive performance than conventional Cox regression (P 30 mL/min/1.73 m(2) and dialysis 20 months). Also in this case combining tree findings and clinical factors improved the predictive performance as compared with conventional Cox model models (P tree model to be an accurate and attractive tool to predict graft failure for patients with specific characteristics. This may aid the evaluation of individual graft prognosis and thereby the design of measures to improve graft survival in the poor prognosis groups. © The Author 2015. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  15. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  16. Anterior cruciate ligament reconstruction failure after tibial shaft malunion.

    Science.gov (United States)

    LaFrance, Russell M; Gorczyca, John T; Maloney, Michael D

    2012-02-17

    Anterior cruciate ligament (ACL) reconstruction is common, with >100,000 procedures performed each year in the United States. Several factors are associated with failure, including poor surgical technique, graft incorporation failure, overly aggressive rehabilitation, and trauma. Tibial shaft fracture is also common and frequently requires operative intervention. Failure to reestablish the anatomic alignment of the tibia may cause abnormal forces across adjacent joints, which can cause degenerative joint disease or attritional failure of the surrounding soft tissues. This article describes a case of ACL reconstruction failure after a tibial fracture that resulted in malunion. Excessive force across the graft from lower-extremity malalignment and improper tunnel placement likely contributed to the attritional failure of the graft. This patient required a staged procedure for corrective tibial osteotomy followed by revision ACL reconstruction. This article describes ACL reconstruction failure, tibial shaft malunions, their respective treatments, the technical details of each procedure, and the technical aspects that must be considered when these procedures are done in a staged manner by 2 surgeons. Copyright 2012, SLACK Incorporated.

  17. Total Artificial Heart as Rescue Therapy for Primary Graft Failure in an Infant.

    Science.gov (United States)

    Ziegler, Luke A; Sainathan, Sandeep; Morell, Victor O; Sharma, Mahesh S

    2018-04-01

    An infant unable to be weaned from cardiopulmonary bypass after orthotopic heart transplantation was cannulated for extracorporeal membrane oxygenation. During the next 3 days, allograft failure and intracardiac thrombosis necessitated cardiectomy. To provide acute mechanical circulatory support, artificial atrial chambers were constructed with Gore-Tex conduits and PediMag centrifugal pumps were connected to each by Berlin Heart EXCOR cannulae. The PediMag pumps were subsequently exchanged for 10-mL Berlin Heart EXCOR pumps. After 60 days of support by total artificial heart, the patient was bridged successfully to a second heart transplant. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Development of a primary melanoma in situ within a full-thickness skin graft overlying a free muscle flap: a case report.

    Science.gov (United States)

    Dabek, Robert J; Baletic, Nemanja; McUmber, Harrison; Nahed, Brian; Haynes, Alex; Eberlin, Kyle R; Bojovic, Branko

    2018-01-01

    The development of a primary melanoma within the confines of free tissue transfer is a rare occurrence. In this report, we describe the development of a primary melanoma in situ within a full-thickness skin graft overlying a free latissimus dorsi muscle flap used to cover a scalp defect.

  19. Late graft explants in endovascular aneurysm repair.

    Science.gov (United States)

    Turney, Eric J; Steenberge, Sean P; Lyden, Sean P; Eagleton, Matthew J; Srivastava, Sunita D; Sarac, Timur P; Kelso, Rebecca L; Clair, Daniel G

    2014-04-01

    institution. Survival is higher when the explant is done electively compared with emergent repair. Difficulty in obtaining a seal at the initial EVAR often leads to failure ≤1 year, whereas progression of aneurysmal disease is the primary reason for failure >5 years. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  20. Heart failure guidelines and prescribing in primary care across Europe

    Directory of Open Access Journals (Sweden)

    Hobbs FD Richard

    2005-08-01

    Full Text Available Abstract Background Major international differences in heart failure treatment have been repeatedly described, but the reasons for these differences remain unclear. National guideline recommendations might be a relevant factor. This study, therefore, explored variation of heart failure guideline recommendations in Europe. Methods Treatment recommendations of 14 national guidelines published after 1994 were analyzed in relation to the heart failure treatment guideline of the European Society of Cardiology. To test potential relations between recommendations and prescribing, national prescribing patterns as obtained by a European study in primary care (IMPROVEMENT-HF were related to selected recommendations in those countries. Results Besides the 14 national guidelines used by primary care physicians in the countries contacted, the European guideline was used in four countries, and separate guidelines for specialists and primary care were available in another four countries. Two countries indicated that no guideline was used up to 2000. Comprehensiveness of the guidelines varied with respect to length, literature included and evidence ratings. Relevant differences in treatment recommendations were seen only in drug classes where evidence had changed recently (β-blockers and spironolactone. The relation between recommendation and prescribing for selected recommendations was inconsistent among countries. Conclusion Differences in guideline recommendations are not sufficient to explain variation of prescribing among countries, thus other factors must be considered.

  1. Primary hepatic lymphoma presenting as fulminant hepatic failure with hyperferritinemia: A case report

    Directory of Open Access Journals (Sweden)

    Haider Fyeza S

    2008-08-01

    Full Text Available Abstract Introduction Primary hepatic lymphoma is an unusual form of non-Hodgkin's lymphoma that usually presents with constitutional symptoms, hepatomegaly and signs of cholestatic jaundice. Diffuse hepatic infiltration is uncommon and presentation with acute hepatic failure even more rare. The presence of markedly elevated ferritin levels can complicate the evaluation process and suggest alternative diagnoses. We present the case of a middle-aged woman exhibiting pancytopenia, hyperferritinemia and rapidly deteriorating to develop acute hepatic failure. Her initial clinical picture led to a working diagnosis of adult onset Still's disease with probable hemophagocytic syndrome before her worsening liver function necessitated a percutaneous liver biopsy and establishment of the final diagnosis of primary hepatic lymphoma. Conclusion Primary hepatic lymphoma is an uncommon malignancy and its manifestation as progressive hepatitis or acute fulminant hepatic failure can be difficult to diagnose. The presence of constitutional symptoms, pancytopenia and high ferritin levels can complicate the evaluation process. A liver biopsy early in the course of liver dysfunction may establish the diagnosis without a higher risk of bleeding complications seen once liver failure sets in.

  2. Low-dose ultraviolet-B irradiation of donor corneal endothelium and graft survival

    International Nuclear Information System (INIS)

    Dana, M.R.; Olkowski, S.T.; Ahmadian, H.; Stark, W.J.; Young, E.M.

    1990-01-01

    Donor rabbit corneal endothelium was pretreated with different doses of ultraviolet (UV-B) irradiation (302 nm) before grafting to test whether allograft survival could be favorably affected in comparison with untreated corneas grafted into the same recipients. Endothelial rejection was observed in 19 of 32 (59%) eyes that received no treatment compared with five of 32 (16%) eyes that received UV-B (P less than 0.001), and increasing doses of UV-B were associated with lower rejection rates (P less than 0.05). Although exposure of donor endothelium significantly reduced endothelial rejection at all doses tested, it resulted in primary graft failure in a substantial proportion of corneas treated at high doses. Class II (Ia) antigen staining of corneal tissue was present in conjunction with clinical evidence of rejection, and the magnitude of staining correlated with the histologic extent of inflammation. Scanning electron microscopy revealed various endothelial cell surface irregularities and membrane defects in high-dose UV-treated corneas. Endothelial cell cultures exposed in vitro to UV-B light showed a dose-dependent loss in cell viability. These data suggest that UV-B pretreatment of donor corneal endothelium prolongs graft survival but that toxic side effects must be carefully controlled

  3. Improving the Outcome of Vein Grafts: Should Vascular Surgeons Turn Veins into Arteries?

    OpenAIRE

    Isaji, Toshihiko; Hashimoto, Takuya; Yamamoto, Kota; Santana, Jeans M.; Yatsula, Bogdan; Hu, Haidi; Bai, Hualong; Jianming, Guo; Kudze, Tambudzai; Nishibe, Toshiya; Dardik, Alan

    2017-01-01

    Autogenous vein grafts remain the gold standard conduit for arterial bypass, particularly for the treatment of critical limb ischemia. Vein graft adaptation to the arterial environment, i.e., adequate dilation and wall thickening, contributes to the superior performance of vein grafts. However, abnormal venous wall remodeling with excessive neointimal hyperplasia commonly causes vein graft failure. Since the PREVENT trials failed to improve vein graft outcomes, new strategies focus on the ada...

  4. ACL Graft Healing and Biologics

    NARCIS (Netherlands)

    Muller, Bart; Bowman, Karl F.; Bedi, Asheesh

    2013-01-01

    Operative reconstruction of a torn anterior cruciate ligament (ACL) has become the most broadly accepted treatment. An important, but underreported, outcome of ACL reconstruction is graft failure, which poses a challenge for the orthopedic surgeon. An understanding of the tendon-bone healing and the

  5. The impact of BWR MK I primary containment failure dynamics on secondary containment integrity

    International Nuclear Information System (INIS)

    Greene, S.R.

    1987-01-01

    During the past four years, the ORNL BWRSAT Program has developed a series of increasingly sophisticated BWR secondary containment models. These models have been applied in a variety of studies to evaluate the severe accident mitigation capability of BWR secondary containments. This paper describes the results of a recent ORNL study of the impact of BWR MK I primary containment failure dynamics on secondary containment integrity. A 26-cell MELCOR Browns Ferry secondary containment model is described and the predicted thermodynamic response of the secondary containment to a variety of postulated primary containment failure modes is presented. The effects of primary containment failure location, timing, and ultimate hole size on secondary containment response is investigated, and the potential impact of hydrogen deflagrations on secondary containment integrity is explored

  6. Long-term results of PTFE grafts.

    Science.gov (United States)

    Hedin, Ulf

    2015-01-01

    Vascular surgeons are essential in "lifeline" creation for hemodialysis patients and should be the central player in any multidisciplinary access service together with nephrologists, dialysis staff and interventional radiology. In this position, access surgeons are involved in complicated clinical decision making regarding primary and secondary access selection, which throughout the last decade has been largely aided, and influenced, by national and international guidelines as well as other initiatives. These recommendations, unanimously and appropriately, advocate the placement of native fistulas over synthetic grafts (the majority grafts from expanded polytetrafluoroethylene, ePTFE, herein referred to as PTFE) based on the superiority of fistulas with respect to complications such as infections and thrombosis. Nevertheless, the use of PTFE grafts for hemodialysis access is an accepted and firmly established alternative to native fistulas where data today reveal unwanted consequences to overinterpretation of established guidelines such as increased catheter use. This information highlights a need for an adjustment of access selection strategies based on patient-centered algorithms. Here, available results on PTFE graft performance in hemodialysis access is recapitulated, with respect to both conventional grafts and technical modifications, and conclude with a modified approach to primary access selection.

  7. Five-year outcomes following a randomized trial of femorofemoral and femoropopliteal bypass grafting with heparin-bonded or standard polytetrafluoroethylene grafts

    DEFF Research Database (Denmark)

    Lindholt, Jes S.; Houlind, K.; Gottschalksen, B

    2016-01-01

    BACKGROUND: Cohort studies suggest superior long-term patency of luminal heparin-bonded polytetrafluoroethylene (Hb-PTFE) bypass grafts compared with standard PTFE grafts. The aim of this study was to compare the outcomes of Hb-PTFE grafts with those of standard PTFE grafts 5 years after...... a randomized trial. METHODS: Patients with intermittent claudication or critical limb ischaemia requiring femorofemoral or femoropopliteal bypass grafting were randomized in a clinical trial of Hb-PTFE versus standard PTFE in 11 Scandinavian centres between 2005 and 2009. Patients were followed up for 5 years...... of the primary outcome. Use of Hb-PTFE significantly improved patency by 37 per cent at 2 years, but 5 years after randomization there was no difference in primary patency (adjusted hazard ratio (HR) 0·95, 95 per cent c.i. 0·71 to 1·28; P = 0·748). In patients with critical limb ischaemia the use of Hb-PTFE...

  8. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  9. Efficacy of duplex ultrasound surveillance after infrainguinal vein bypass may be enhanced by identification of characteristics predictive of graft stenosis development.

    Science.gov (United States)

    Tinder, Chelsey N; Chavanpun, Joe P; Bandyk, Dennis F; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2008-09-01

    Controversy regarding the efficacy of duplex ultrasound surveillance after infrainguinal vein bypass led to an analysis of patient and bypass graft characteristics predictive for development of graft stenosis and a decision of secondary intervention. Retrospective analysis of a contemporary, consecutive series of 353 clinically successful infrainguinal vein bypasses performed in 329 patients for critical (n = 284; 80%) or noncritical (n = 69; 20%) limb ischemia enrolled in a surveillance program to identify and repair duplex-detected graft stenosis. Variables correlated with graft stenosis and bypass repair included: procedure indication, conduit type (saphenous vs nonsaphenous vein; reversed vs nonreversed orientation), prior bypass graft failure, postoperative ankle-brachial index (ABI) < 0.85, and interpretation of the first duplex surveillance study as "normal" or "abnormal" based on peak systolic velocity (PSV) and velocity ratio (Vr) criteria. Overall, 126 (36%) of the 353 infrainguinal bypasses had 174 secondary interventions (endovascular, 100; surgery, 74) based on duplex surveillance; resulting in 3-year Kaplan-Meier primary (46%), assisted-primary (80%), and secondary (81%) patency rates. Characteristics predictive of duplex-detected stenosis leading to intervention (PSV: 443 +/- 94 cm/s; Vr: 8.6 +/- 9) were: "abnormal" initial duplex testing indicating moderate (PSV: 180-300 cm/s, Vr: 2-3.5) stenosis (P < .0001), non-single segment saphenous vein conduit (P < .01), warfarin drug therapy (P < .01), and redo bypass grafting (P < .001). Procedure indication, postoperative ABI level, statin drug therapy, and vein conduit orientation were not predictive of graft revision. The natural history of 141 (40%) bypasses with an abnormal first duplex scan differed from "normal" grafts by more frequent (51% vs 24%, P < .001) and earlier (7 months vs 11 months) graft revision for severe stenosis and a lower 3-year assisted primary patency (68% vs 87%; P < .001). In 52

  10. Differences in mechanisms of failure, intraoperative findings, and surgical characteristics between single- and multiple-revision ACL reconstructions: a MARS cohort study.

    Science.gov (United States)

    Chen, James L; Allen, Christina R; Stephens, Thomas E; Haas, Amanda K; Huston, Laura J; Wright, Rick W; Feeley, Brian T

    2013-07-01

    The factors that lead to patients failing multiple anterior cruciate ligament (ACL) reconstructions are not well understood. Multiple-revision ACL reconstruction will have different characteristics than first-time revision in terms of previous and current graft selection, mode of failure, chondral/meniscal injuries, and surgical charactieristics. Case-control study; Level of evidence, 3. A prospective multicenter ACL revision database was utilized for the time period from March 2006 to June 2011. Patients were divided into those who underwent a single-revision ACL reconstruction and those who underwent multiple-revision ACL reconstructions. The primary outcome variable was Marx activity level. Primary data analyses between the groups included a comparison of graft type, perceived mechanism of failure, associated injury (meniscus, ligament, and cartilage), reconstruction type, and tunnel position. Data were compared by analysis of variance with a post hoc Tukey test. A total of 1200 patients (58% men; median age, 26 years) were enrolled, with 1049 (87%) patients having a primary revision and 151 (13%) patients having a second or subsequent revision. Marx activity levels were significantly higher (9.77) in the primary-revision group than in those patients with multiple revisions (6.74). The most common cause of reruptures was a traumatic, noncontact ACL graft injury in 55% of primary-revision patients; 25% of patients had a nontraumatic, gradual-onset recurrent injury, and 11% had a traumatic, contact injury. In the multiple-revision group, a nontraumatic, gradual-onset injury was the most common cause of recurrence (47%), followed by traumatic noncontact (35%) and nontraumatic sudden onset (11%) (P < .01 between groups). Chondral injuries in the medial compartment were significantly more common in the multiple-revision group than in the single-revision group, as were chondral injuries in the patellofemoral compartment. Patients with multiple-revision ACL

  11. Mechanical properties of human bone-tendon-bone grafts preserved by different methods and radiation sterilised

    International Nuclear Information System (INIS)

    Kaminski, A.; Gut, G.

    2008-01-01

    Full text: Patellar tendon auto and allografts are commonly used in orthopaedic surgery for reconstruction of the anterior crucial ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infection diseases transmission allografts should be radiation-sterilised. As radiation-sterilisation is supposed to decrease the mechanical strength of tendon tissue, it is important to establish methods of allografts preservation and sterilisation resulting in their best quality and safety. Therefore, the purpose of the study was to compare the tensile strength of the central one third of human patellar tendon (as used for ACL reconstruction), preserved by different methods (deep fresh freezing, lyophilisation) and subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. Bone-tendon-bone grafts were prepared from cadaveric human patella tendon with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glicerolisation or lyophilisation and radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. To estimate mechanical properties all samples were subjected to tensile tests to failure using Instron system. Before these tests all lyophilised grafts were rehydrated. We found decrease of tensile strength of irradiated grafts compared to non-irradiated controls. Obtained results of the mechanical testing of studied grafts indicate their potential usefulness for clinical applications.(Author)

  12. Anastomotic fibrous ring as cause of stricture recurrence after bulbar onlay graft urethroplasty.

    Science.gov (United States)

    Barbagli, Guido; Guazzoni, Giorgio; Palminteri, Enzo; Lazzeri, Massimo

    2006-08-01

    We retrospectively reviewed patterns of failure after bulbar substitution urethroplasty. In particular we investigated the prevalence and location of anastomotic fibrous ring strictures occurring at the apical anastomoses between the graft and urethral plate after 3 types of onlay graft techniques. We reviewed the records of 107 patients who underwent bulbar urethroplasty between 1994 and 2004. Mean patient age was 44 years. Patients with lichen sclerosus, failed hypospadias repair or urethroplasty and panurethral strictures were excluded. A total of 45 patients underwent dorsal onlay skin graft urethroplasty, 50 underwent buccal mucosa onlay graft urethroplasty and 12 underwent augmented end-to-end urethroplasty. The clinical outcome was considered a success or failure at the time that any postoperative procedure was needed, including dilation. Mean followup was 74 months (range 12 to 130). Of 107 cases 85 (80%) were successful and 22 (20%) failed. Failure in 12 patients (11%) involved the whole grafted area and in 10 (9%) it involved the anastomotic site, which was distal and proximal in 5 each. Urethrography, urethral ultrasound and urethroscopy were fundamental for determining the difference between full-length and focal extension of re-stricture. Failures were treated with multistage urethroplasty in 12 cases, urethrotomy in 7 and 1-stage urethroplasty in 3. Of the patients 16 had a satisfactory final outcome and 6 underwent definitive perineal urinary diversion. The prevalence and location of anastomotic ring strictures after bulbar urethroplasty were uniformly distributed in after 3 surgical techniques using skin or buccal mucosa. Further studies are necessary to clarify the etiology of these fibrous ring strictures.

  13. Comparison of FLIXENE™ and standard PTFE arteriovenous graft for early haemodialysis.

    Science.gov (United States)

    Chiang, Nathaniel; Hulme, Katherine Ria; Haggart, Paul Charles; Vasudevan, Thodur

    2014-01-01

    The purpose is to compare the outcomes of FLIXENE™ arteriovenous graft (AVG) to standard polytetrafluoroethylene (PTFE) AVG for early haemodialysis. This is a prospective observational study of all AVGs placed over a 40-month period between 2008 and 2011 at our vascular unit. Primary outcome was to examine early cannulation rates for FLIXENE™. Secondary outcomes included patency rates, usability of grafts, complications in particular infections, interventions and death in comparison to standard PTFE grafts. Forty-five FLIXENE™ and 19 standard PTFE AVGs were placed in the study period; 89% of FLIXENE™ grafts were used for dialysis, with 78% cannulated within 3 days. At 18 months, primary patency (FLIXENE™ 34% vs standard PTFE 24%), primary assisted patency (35% vs 36%) and secondary patency rate (51% vs 48%) were not statistically different; 20.2% of FLIXENE™ grafts were infected at 18 months requiring explantation compared with 40.3% of standard PTFE grafts (p=0.14). FLIXENE™ can be cannulated for dialysis within 3 days. It has similar patency and complication rates as other prosthetic grafts in the market. In patients who have no access and require urgent dialysis, FLIXENE™ is a viable option.

  14. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    Science.gov (United States)

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon

  15. A Review on Grafting of Biofibers for Biocomposites.

    Science.gov (United States)

    Wei, Liqing; McDonald, Armando G

    2016-04-22

    A recent increase in the use of biofibers as low-cost and renewable reinforcement for the polymer biocomposites has been seen globally. Biofibers are classified into: lignocellulosic fibers ( i.e. , cellulose, wood and natural fibers), nanocellulose ( i.e. , cellulose nanocrystals and cellulose nanofibrils), and bacterial cellulose, while polymer matrix materials can be petroleum based or bio-based. Green biocomposites can be produced using both biobased fibers and polymers. Incompatibility between the hydrophilic biofibers and hydrophobic polymer matrix can cause performance failure of resulting biocomposites. Diverse efforts have focused on the modification of biofibers in order to improve the performances of biocomposites. "Grafting" copolymerization strategy can render the advantages of biofiber and impart polymer properties onto it and the performance of biocomposites can be tuned through changing grafting parameters. This review presents a short overview of various "grafting" methods which can be directly or potentially employed to enhance the interaction between biofibers and a polymer matrix for biocomposites. Major grafting techniques, including ring opening polymerization, grafting via coupling agent and free radical induced grafting, have been discussed. Improved properties such as mechanical, thermal, and water resistance have provided grafted biocomposites with new opportunities for applications in specific industries.

  16. The relationship between revascularisation and osteogenesis in fresh or demineralised bone grafts

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    2001-01-01

    Bone formation generally depends on adequate blood flow. Failure of bone grafts has been attributed to delayed revascularisation of the graft. We compared the relationship between revascularisation and osteogenesis, evaluated as entrapment of (141)Ce-labelled microspheres and uptake of (85)Sr......, respectively, in fresh or demineralised syngeneic bone grafts 3 weeks after heterotopic implantation in rats. Whereas a moderately high linear correlation between (85)Sr and (141)Ce radioactivity was found both in the (intact) host iliac bone (r = 0.75, p = 0.0001) and implanted fresh syngeneic grafts (r = 0...

  17. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  18. Graft type for femoro-popliteal bypass surgery.

    Science.gov (United States)

    Ambler, Graeme K; Twine, Christopher P

    2018-02-11

    Femoro-popliteal bypass is implemented to save limbs that might otherwise require amputation, in patients with ischaemic rest pain or tissue loss; and to improve walking distance in patients with severe life-limiting claudication. Contemporary practice involves grafts using autologous vein, polytetrafluoroethylene (PTFE) or Dacron as a bypass conduit. This is the second update of a Cochrane review first published in 1999 and last updated in 2010. To assess the effects of bypass graft type in the treatment of stenosis or occlusion of the femoro-popliteal arterial segment, for above- and below-knee femoro-popliteal bypass grafts. For this update, the Cochrane Vascular Information Specialist searched the Vascular Specialised Register (13 March 2017) and CENTRAL (2017, Issue 2). Trial registries were also searched. We included randomised trials comparing at least two different types of femoro-popliteal grafts for arterial reconstruction in patients with femoro-popliteal ischaemia. Randomised controlled trials comparing bypass grafting to angioplasty or to other interventions were not included. Both review authors (GKA and CPT) independently screened studies, extracted data, assessed trials for risk of bias and graded the quality of the evidence using GRADE criteria. We included nineteen randomised controlled trials, with a total of 3123 patients (2547 above-knee, 576 below-knee bypass surgery). In total, nine graft types were compared (autologous vein, polytetrafluoroethylene (PTFE) with and without vein cuff, human umbilical vein (HUV), polyurethane (PUR), Dacron and heparin bonded Dacron (HBD); FUSION BIOLINE and Dacron with external support). Studies differed in which graft types they compared and follow-up ranged from six months to 10 years.Above-knee bypassFor above-knee bypass, there was moderate-quality evidence that autologous vein grafts improve primary patency compared to prosthetic grafts by 60 months (Peto odds ratio (OR) 0.47, 95% confidence interval (CI

  19. An analysis of surgical and anaesthetic factors affecting skin graft viability in patients admitted to a Burns Intensive Care Unit.

    Science.gov (United States)

    Isitt, Catherine E; McCloskey, Kayleigh A; Caballo, Alvaro; Sharma, Pranev; Williams, Andrew; Leon-Villapalos, Jorge; Vizcaychipi, Marcela P

    2016-01-01

    Skin graft failure is a recognised complication in the treatment of major burns. Little research to date has analysed the impact of the complex physiological management of burns patients on the success of skin grafting. We analysed surgical and anaesthetic variables to identify factors contributing to graft failure. Inclusion criteria were admission to our Burns Intensive Care Unit (BICU) between January 2009 and October 2013 with a major burn. After exclusion for death before hospital discharge or prior skin graft at a different hospital, 35 patients remained and were divided into those with successful autografts (n=16) and those with a failed autograft (n=19). For the purposes of this study, we defined poor autograft viability as requiring at least one additional skin graft to the same site. Logistic regression of variables was performed using SPSS (Version 22.0 IBMTM). Age, Sex, %Total Burn Surface Area or Belgian Outcome Burns Injury score did not significantly differ between groups. No differences were found in any surgical factor at logistic regression (graft site, harvest site, infection etc.). When all operations were analysed, the use of colloids was found to be significantly associated with graft failure (p=0.035, CI 95%) and this remained significant when only split thickness skin grafts (STSGs) and debridement operations were included (p=0.034, CI 95%). No differences were found in crystalloid use, intraoperative temperature, pre-operative haemoglobin and blood products or vasopressor use. This analysis highlights an independent association between colloids and graft failure which has not been previously documented.

  20. A comparison of skin graft success in the head & neck with and without the use of a pressure dressing.

    Science.gov (United States)

    Dhillon, M; Carter, C P; Morrison, J; Hislop, W S; Currie, W J R

    2015-06-01

    The success of skin grafting is dependent on the interplay between many factors including nutrient uptake and vascular in-growth. To allow this, it is important that the graft is immobile and traditionally a 'pressure dressing' has been placed over the graft to improve outcome and graft 'take'. We present the findings of our comparative study of full-thickness skin grafts performed in the head, neck and face region over a period of 24 months. We felt that there was an unacceptably high infection rate and graft failure using pressure dressings. Data was collected retrospectively from the case notes on 70 patients who had undergone full-thickness skin grafting to the head, neck and face over a 2 year period. Thirty-five patients underwent grafting with pressure dressing and 35 without. The group with the pressure dressing had the same 'bolster' specification-type dressing and those without had their graft 'quilted' in and chloramphenicol ointment applied topically. Success was determined by the percentage 'take' of the grafts and absence of infection i.e. purulence. Infection in those with a pressure dressing stood at 26 % in contrast to those without, at 9 %. Without a pressure dressing we observed no total graft failures, compared to 6 % in those with a pressure dressing. The results confirmed the perception that there was a higher infection and graft failure rate where a pressure dressing was applied; however, this was not a statistically significant difference and a randomised control trial with a larger sample size would be required to validate the results.

  1. Avoiding secondary skin graft donor site morbidity in the fibula free flap harvest.

    Science.gov (United States)

    Kim, Paul D; Fleck, Terry; Heffelfinger, Ryan; Blackwell, Keith E

    2008-12-01

    To compare donor site morbidity in patients who have undergone fibula free flap reconstruction in which the skin graft was taken from the expected cutaneous paddle of the fibula with the known complications of the popular technique of obtaining a split-thickness skin graft (STSG) from a secondary donor site. Cohort study. The tertiary care centers at Loma Linda University Medical Center and University of California, Los Angeles, Medical Center. From September 1, 2006, to March 30, 2007, 30 patients underwent fibula free flap harvest by 2 surgeons at separate tertiary care centers. Twenty-one of those procedures took place at the University of California, Los Angeles, and 9 at Loma Linda University. Patients included 15 men (50%) and 15 women (50%), with a mean age of 58 (range, 19-88) years. All 30 patients underwent fibula free flap harvest with a split-thickness skin graft (graft thickness, 0.04 cm), obtained from osteocutaneous paddle using a 5.1-cm-wide dermatome, as well as oral cavity and oropharyngeal reconstruction with the de-epithelialized skin paddle. Measures of donor site morbidity, including graft failure and wound breakdown, and measures of recipient site morbidity, including flap failure, hardware complications, intraoral complications, and the need for additional surgery. Of the 30 patients who underwent this procedure, 4 had partial skin graft failures, for a complete skin graft survival of 87%. There were no complete skin graft losses. Regarding the fibula osteocutaneous free flap, there were no complete flap losses, 1 skin paddle necrosis that required debridement, 2 postoperative orocutaneous fistulas, 1 case of infected/extruded hardware, and 1 adhesion formation that required additional surgery for lysis of adhesion and placement of the split-thickness skin graft. The outlined novel technique has similar rates of free flap survival and skin graft take compared with previously described methods. Harvesting the skin graft over the expected

  2. Revision of unicompartmental knee arthroplasty: implants used and causes of failure

    Directory of Open Access Journals (Sweden)

    Alan de Paula Mozella

    2014-04-01

    Full Text Available OBJECTIVE: to determine the causes of unicondylar knee arthroplasty failures, as well as identify the implants used and the need of bone grafting in patients undergoing revision UKA in Center of Knee Surgery at the Instituto Nacional de Traumatologia e Ortopedia (INTO in the period between January 1990 and January 2013.METHODS: a retrospective analysis of the medical documentation and imaging, determining the cause of failure of UKA and the time of its occurrence, as well as prosthetic components implanted during the review and the need for bone grafting.RESULTS: in this study, 27 UKA failures in 26 patients were included. Collapse of one or more components was the main cause of failure, occurring in 33% of patients. Aseptic failure was identified in 30% of cases, progression of osteoarthrosis in 15%, infection and pain 7% each, and osteolysis and polyethylene failure in 4% each. Early failure occurred in 41% of all revisions of UKA and late failure in 59%. 23 patients have undergone revision of UK.CONCLUSION: in 35% of revisions the use of bone grafting was needed in tibial area; in 3 cases we needed allograft from Tissue Bank. We did not use metal increase in any of the revision. In one patient we used implant constraint for instability.

  3. HPV16-E7-Specific Activated CD8 T Cells in E7 Transgenic Skin and Skin Grafts

    Directory of Open Access Journals (Sweden)

    Seyed Davoud Jazayeri

    2017-05-01

    Full Text Available Human papillomavirus (HPV 16 E7 (E7 protein expression in skin promotes epithelial hyperproliferation and transformation to malignancy. Grafts of murine skin expressing E7 protein as a transgene in keratinocytes are not rejected from immunocompetent recipients, whereas grafts expressing ovalbumin (OVA, with or without coexpression of E7 protein, are promptly rejected, demonstrating that E7-associated non-antigen-specific local immunosuppression is not a major determinant of lack of rejection of E7 transgenic skin. To determine whether failure of rejection of E7 skin grafts is due to failure to attract E7-specific effector T cells, E7- and OVA-specific effector CD8+ T cells, activated in vitro, were transferred to animals bearing E7 transgenic skin grafts. Three days after T cell transfer, E7-specific T cells were present in significantly greater numbers than OVA-specific T cells in the grafted skin on animals bearing recently placed or healed E7 grafts, without graft rejection, and also in the ear skin of E7 transgenic animals, without obvious pathology. E7 and OVA-specific T cells were present in lesser numbers in healed E7 grafts than in recently placed grafts and in lesser numbers in recently placed E7 transgenic epidermal grafts without E7-associated hyperproliferation, derived from E7 transgenic mice with a mutated retinoblastoma gene. These data demonstrate that effector T cells are to some extent attracted to E7 transgenic skin specifically by E7 expression, but in large measure non-specifically by the epithelial proliferation associated with E7 expression, and by the local inflammation produced by grafting. Failure of E7 graft rejection was observed despite trafficking of E7-specific effector T cells to E7-expressing epithelium, a finding of consequence for immunotherapy of HPV 16 E7-associated human cancers.

  4. Association of helicobacter pylori dupA with the failure of primary eradication.

    Science.gov (United States)

    Shiota, Seiji; Nguyen, Lam Tung; Murakami, Kazunari; Kuroda, Akiko; Mizukami, Kazuhiro; Okimoto, Tadayoshi; Kodama, Masaaki; Fujioka, Toshio; Yamaoka, Yoshio

    2012-04-01

    To determine whether the presence of dupA Helicobacter pylori (H. pylori) influences the cure rate of primary eradication therapy. Several virulence factors of H. pylori have been reported to affect the efficacy of the eradication rate. However, no study has investigated whether the presence of dupA affects eradication failure. The presence of dupA was evaluated in 142 H. pylori strains isolated from 142 patients with gastrointestinal diseases. Of these patients, 104 received primary eradication therapy for 1 week. The risk factors for eradication failure were determined using univariate and multivariate analyses. Among 142 strains, 44 (31.0%) were dupA positive. There was no association between dupA status and gastroduodenal diseases (P>0.05). The clarithromycin (CLR) resistance rate was generally lower in the dupA-positive than in the dupA-negative group (20.4% vs. 35.7%, P=0.06). However, dupA prevalence was higher in the eradication failure group than in the success group (36.3% vs. 21.9%). Among the CLR-resistant H. pylori infected group, the successful eradication rate was significantly lower in patients infected with dupA-positive H. pylori than dupA-negative H. pylori (P=0.04). In multivariate analysis adjusted for age, sex, and type of disease, not only CLR resistance but also dupA presence was independent risk factors for eradication failure (adjusted odds ratio=3.71; 95% confidence interval,1.07-12.83). Although CLR resistant was more reliable predictor, the presence of dupA may also be an independent risk factor for eradication failure.

  5. Comparative analysis of use of porous orbital implant with mucus membrane graft and dermis fat graft as a primary procedure in reconstruction of severely contracted socket

    Directory of Open Access Journals (Sweden)

    Kasturi Bhattacharjee

    2014-01-01

    Full Text Available Purpose: The purpose of our study is to present a surgical technique of primary porous orbital ball implantation with overlying mucus membrane graft (MMG for reconstruction of severely contracted socket and to evaluate prosthesis retention and motility in comparison to dermis fat graft (DFG. Study Design: Prospective comparative study. Materials and Methods: A total of 24 patients of severe socket contracture (Grade 2-4 Krishna′s classification were subdivided into two groups, 12 patients in each group. In Group I, DFG have been used for reconstruction. In Group II, porous polyethylene implant with MMG has been used as a primary procedure for socket reconstruction. In Group I DFG was carried out in usual procedure. In case of Group II, vascularized scar tissues were separated 360° and were fashioned into four strips. A scleral capped porous polyethylene implant was placed in the intraconal space and four strips of scar tissue were secured to the scleral cap and extended part overlapped the implant to make a twofold barrier between the implant and MMG. Patients were followed-up as per prefixed proforma. Prosthesis motility and retention between the two groups were measured. Results: In Group I, four patients had recurrence of contracture with fall out of prosthesis. In Group II stable reconstruction was achieved in all the patients. In terms of prosthesis motility, maximum in Group I was 39.2% and Group II, was 59.3%. The difference in prosthesis retention (P = 0.001 and motility (P = 0.004 between the two groups was significant. Conclusion: Primary socket reconstruction with porous orbital implant and MMG for severe socket contracture is an effective method in terms of prosthesis motility and prosthesis retention.

  6. Overdiagnosis of heart failure in primary care : A cross-sectional study

    NARCIS (Netherlands)

    Valk, Mark J.; Mosterd, Arend; Broekhuizen, Berna D L; Zuithoff, Nicolaas P A; Landman, Marcel A J; Hoes, Arno W.; Rutten, Frans H.

    2016-01-01

    Background Access to echocardiography in primary care is limited, but is necessary to accurately diagnose heart failure (HF). Aim To determine the proportion of patients with a GP's diagnosis of HF who really have HF. Design and setting A cross-sectional study of patients in 30 general practices

  7. Failed anterior cruciate ligament reconstruction: analysis of factors leading to instability after primary surgery.

    Science.gov (United States)

    Ma, Yong; Ao, Ying-Fang; Yu, Jia-Kuo; Dai, Ling-Hui; Shao, Zhen-Xing

    2013-01-01

    Revision anterior cruciate ligament (ACL) surgery can be expected to become more common as the number of primary reconstruction keeps increasing. This study aims to investigate the factors causing instability after primary ACL reconstruction, which may provide an essential scientific base to prevent surgical failure. One hundred and ten revision ACL surgeries were performed at our institute between November 2001 and July 2012. There were 74 men and 36 women, and the mean age at the time of revision was 27.6 years (range 16 - 56 years). The factors leading to instability after primary ACL reconstruction were retrospectively reviewed. Fifty-one knees failed because of bone tunnel malposition, with too anterior femoral tunnels (20 knees), posterior wall blowout (1 knee), vertical femoral tunnels (7 knees), too posterior tibial tunnels (12 knees), and too anterior tibial tunnels (10 knees). There was another knee performed with open surgery, where the femoral tunnel was drilled through the medial condyle and the tibial tunnel was too anterior. Five knees were found with malposition of the fixation. One knee with allograft was suspected of rejection and a second surgery had been made to take out the graft. Three knees met recurrent instability after postoperative infection. The other factors included traumatic (48 knees) and unidentified (12 knees). Technical errors were the main factors leading to instability after primary ACL reconstructions, while attention should also be paid to the risk factors of re-injury and failure of graft incorporation.

  8. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  9. Review of factors affecting the growth and survival of follicular grafts

    Directory of Open Access Journals (Sweden)

    William M Parsley

    2010-01-01

    Full Text Available Great strides have been made in hair restoration over the past 20 years. A better understanding of natural balding and non-balding patterns along with more respect for ageing has helped guide proper hairline design. Additionally, the use of smaller grafts has created a significantly improved natural appearance to the transplanted grafts. Inconsistent growth and survival of follicular grafts, however, has continued to be a problem that has perplexed hair restoration surgeons. This review attempts to explore the stresses affecting grafts during transplantation and some of the complexities involved in graft growth and survival. These authors reviewed the literature to determine the primary scope of aspects influencing growth and survival of follicular grafts. This scope includes patient selection, operating techniques, graft care, storage solutions and additives. The primary focus of the hair restoration surgeons should first be attention to the fundamentals of hair care, hydration, temperature, time out of body and gentle handling. Factors such as advanced storage solutions and additives can be helpful once the fundamentals have been addressed.

  10. Attenuation of primary nonfunction for syngeneic islet graft using sodium 4-phenylbutyrate.

    Science.gov (United States)

    Fu, S-H; Chen, S-T; Hsu, B R-S

    2005-05-01

    Sodium 4-phenylbutyrate (4-SPB), an aromatic derivative of butyric acid, was examined to elucidate its effect on islet engraftment in a syngeneic transplantation model using C57BL/6 mice. Diabetic mice that received subrenal implantation of 150 islets on day 0 and oral administration of twice daily 4-SPB (500 mg/kg body weight) on days -2 through 28 displayed a significantly shorter duration of posttransplantation temporary hyperglycemia than diabetic mice that received islets in isotonic sodium chloride solution (NaCl), namely 16 +/- 2 (n = 12) vs 23 +/- 2 days (n = 7; P < .05). Four weeks after transplantation, the insulin content (IC) of grafts from mice treated with islets and 4-SPB was substantially higher than that of grafts from mice treated with islets and NaCl, namely 2.59 +/- 0.37 (n = 8) vs 1.36 +/- 0.36 mug (n = 13; P < .01). The IC of pancreatic remnants showed no significant difference between groups after 2 and 4 weeks of incubation. In vitro studies demonstrated that the net glucose-stimulated insulin secretion (GSIS) and the ratio of net GSIS to the IC of islets cultured with 4-SPB (1 mM) did not differ significantly from those cultured with NaCl. The lipopolysaccharide-stimulated secretions of IL-1beta, IL-10, and IFNgamma from peritoneal exudate monocytes were significantly reduced by co-incubation with 4-SPB (1 mM). In conclusion, our data suggest that daily administration of 4-SPB reduces primary nonfunction and enhances islet engraftment in a syngeneic mouse transplantation model.

  11. PVDF multifilament yarns grafted with polystyrene induced by γ-irradiation: Influence of the grafting parameters on the mechanical properties

    International Nuclear Information System (INIS)

    Marmey, P.; Porte, M.C.; Baquey, Ch.

    2003-01-01

    The development of alternative prosthetic materials for cardiovascular applications has found growing interest due to the failure to date to be able to implement functional patent small diameter vascular grafts (diameter <5 mm). For instance, the successful implantation of small diameter polyester (PET) and expanded polytetrafluoroethylene (PTFEe) vascular grafts has not been achieved in humans. Our strategy is to work with a new multifilament yarns biomaterial, produced from polyvinylidene fluoride (PVDF), which shows suitable mechanical properties, such as a lower tensile modulus than PET and PTFEe. The required biological properties sought for (i.e. low thrombogenicity) could be achieved by 'heparin-like' surface modification treatments in order to modify the thrombogenicity levels of the polymeric materials [Ann. Biomed. Eng. 7 (1979) 429]. A four step method is necessary to achieve this 'heparin-like' surface transformation [J. Biomed. Mater. Res. 52 (2000) 119]. The first step consists in grafting polystyrene onto the PVDF surface by γ irradiation. The purpose of this study was to evaluate the influence of grafting parameters on the mechanical properties: (i) γ-ray irradiation time and (ii) grafting time of styrene monomers, which polymerize and form polystyrene bound to the PVDF surface

  12. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  13. Consequences of cold-ischemia time on primary nonfunction and patient and graft survival in liver transplantation: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    James E Stahl

    2008-06-01

    Full Text Available The ability to preserve organs prior to transplant is essential to the organ allocation process.The purpose of this study is to describe the functional relationship between cold-ischemia time (CIT and primary nonfunction (PNF, patient and graft survival in liver transplant.To identify relevant articles Medline, EMBASE and the Cochrane database, including the non-English literature identified in these databases, was searched from 1966 to April 2008. Two independent reviewers screened and extracted the data. CIT was analyzed both as a continuous variable and stratified by clinically relevant intervals. Nondichotomous variables were weighted by sample size. Percent variables were weighted by the inverse of the binomial variance.Twenty-six studies met criteria. Functionally, PNF% = -6.678281+0.9134701*CIT Mean+0.1250879*(CIT Mean-9.895352-0.0067663*(CIT Mean-9.895353, r2 = .625, , p<.0001. Mean patient survival: 93% (1 month, 88% (3 months, 83% (6 months and 83% (12 months. Mean graft survival: 85.9% (1 month, 80.5% (3 months, 78.1% (6 months and 76.8% (12 months. Maximum patient and graft survival occurred with CITs between 7.5-12.5 hrs at each survival interval. PNF was also significantly correlated with ICU time, % first time grafts and % immunologic mismatches.The results of this work imply that CIT may be the most important pre-transplant information needed in the decision to accept an organ.

  14. ACL graft constructs: In-vitro fatigue testing highlights the occurrence of irrecoverable lengthening and the need for adequate (pre)conditioning to avert the recurrence of knee instability.

    Science.gov (United States)

    Blythe, A; Tasker, T; Zioupos, P

    2006-01-01

    The performance of ACL grafts in both the short and long term is only as good as the condition of the graft at the time of surgery. If the graft lengthens under load at the two fixation ends incorporation will take longer to occur. Previous studies have shown that the various grafts currently used are strong enough. However, data on strength came primarily from quasistatic single pull to failure tests with, in some cases, modest cycling to precondition the grafts. The present study examined the in-vitro biomechanical behaviour of model ACL grafts, which have been fatigue cycled to failure over a wide range of loads in physiological ambient conditions. Load/deformation curves and the stretch of the grafts was continuously recorded until final rupture. The grafts demonstrated typical creep-rupture like behaviour with elongation (non-recoverable stretch) and loss of stiffness leading to gradual failure. Some of the graft designs were consistently shown to elongate up to 20 mm in length within the first 2000 cycles at moderate physiological loads and a further 10 mm of elongation occurred between the initial preconditioned state and just prior to complete rupture. Not enough attention has been paid previously to the likely long term elongation patterns of ACL grafts post-surgery and even after the usual empirical preconditioning has been performed by the surgeon. Increased graft dimensions may result in recurrent knee instability and may also lead to failure of the graft to incorporate. Preconditioning in-vitro may still be a way to remove some slack and prepare the graft for its operational environment by stiffening in particular the tissue/fixation interface for those grafts that use soft polymer fixation ends.

  15. Peak Serum AST Is a Better Predictor of Acute Liver Graft Injury after Liver Transplantation When Adjusted for Donor/Recipient BSA Size Mismatch (ASTi

    Directory of Open Access Journals (Sweden)

    Kyota Fukazawa

    2014-01-01

    Full Text Available Background. Despite the marked advances in the perioperative management of the liver transplant recipient, an assessment of clinically significant graft injury following preservation and reperfusion remains difficult. In this study, we hypothesized that size-adjusted AST could better approximate real AST values and consequently provide a better reflection of the extent of graft damage, with better sensitivity and specificity than current criteria. Methods. We reviewed data on 930 orthotopic liver transplant recipients. Size-adjusted AST (ASTi was calculated by dividing peak AST by our previously reported index for donor-recipient size mismatch, the BSAi. The predictive value of ASTi of primary nonfunction (PNF and graft survival was assessed by receiver operating characteristic curve, logistic regression, Kaplan-Meier survival, and Cox proportional hazard model. Results. Size-adjusted peak AST (ASTi was significantly associated with subsequent occurrence of PNF and graft failure. In our study cohort, the prediction of PNF by the combination of ASTi and PT-INR had a higher sensitivity and specificity compared to current UNOS criteria. Conclusions. We conclude that size-adjusted AST (ASTi is a simple, reproducible, and sensitive marker of clinically significant graft damage.

  16. Prosthetic above-knee femoropopliteal bypass grafting: five-year results of a randomized trial.

    Science.gov (United States)

    Green, R M; Abbott, W M; Matsumoto, T; Wheeler, J R; Miller, N; Veith, F J; Money, S; Garrett, H E

    2000-03-01

    This trial was designed to identify factors affecting patency rates of primary prosthetic above-knee femoropopliteal bypass grafts at 5 years. A multi-institutional, prospective trial randomized 240 patients to compare patency rates of Gore-tex and Hemashield above-knee femoropopliteal bypass grafts at 5 years. Univariate comparisons of patency between levels of each prognostic variable were made with the Kaplan-Meier method. Variables that had a univariate P value less than.25 or those known to be important were submitted to a Cox regression analysis. The patient survival rate at 5 years was 59.4%. There were no differences in primary or secondary patency rates at 5 years between the two graft materials (primary, 45% vs 43% and secondary, 68% vs 68%). The risk for graft occlusion was significantly increased for patients younger than 65 years (2.1; P =.001) and for grafts with a diameter less than 7 mm (1.65; P =.0219). Variables with no apparent independent effect on patency rates were smoking status, runoff, diabetes mellitus, sex, presenting symptoms, and postoperative treatment with aspirin or Coumadin. Noninvasive test results were not predictive of subsequent graft function. Although the type of prosthetic used for above-knee femoropopliteal bypass grafts does not affect 5-year patency rates, age and graft size do influence results. These factors should be considered before a prosthetic bypass grafting procedure. Furthermore, these data should serve as a contemporary standard, with which evolving and conventional procedures can be compared.

  17. Success rate and risk factors of failure of the induced membrane technique in children: a systematic review.

    Science.gov (United States)

    Aurégan, Jean-Charles; Bégué, Thierry; Rigoulot, Guillaume; Glorion, Christophe; Pannier, Stéphanie

    2016-12-01

    The induced membrane technique was designed by Masquelet et al. to address segmental bone defects of critical size in adults. It has been used after bone defects of traumatic, infectious and tumoral origin with satisfactory results. Recently, it has been used in children but, after an initial enthusiasm, several cases of failure have been reported. The purpose of this study was to assess the success rate and the risk factors of failure of the induced membrane for children. We conducted a systematic review of all the studies reporting the results of the induced membrane technique to address bone defects of critical size in children. Our primary outcome was the success rate of the technique defined as a bone union before any iterative surgery. Our secondary outcomes were the complications and the risk factors of failure. We searched Medline via Pubmed, EMBASE and the Cochrane Library. Twelve studies, including 69 patients, met the inclusion criteria. There were 41 boys and 28 girls. Mean age at surgery was 10 years. Mean size of resection was 12.38 cm and the mean time between the two stages was 5.86 months. Mean rate of bone union after the two stages of the induced membrane technique was 58% (40/69) but this rate increased to 87% after revision surgeries (60/69). Main complications were non-unions (19/69), lysis of the graft (6/69) and fractures of the bone graft (6/69). Only 1/69 deep infection was reported. Other non specific complications were regularly reported such limb length discrepancies, joint stiffness and protruding wires. Risk factor of failure that could be suspected comprised the resection of a malignant tumour, a bone defect located at the femur, a wide resection, a long time between the two stages, an unstable osteosynthesis and a bone graft associating autograft to other graft materials. The induced membrane technique is suitable for bone defects of critical size in children. It is a reliable technique with no need of micro vascular surgery

  18. Fulminant Hepatic Failure Secondary to Primary Hepatic Angiosarcoma

    Directory of Open Access Journals (Sweden)

    Ayokunle T. Abegunde

    2015-01-01

    Full Text Available Background. Hepatic angiosarcoma is a rare and aggressive tumor that often presents at an advanced stage with nonspecific symptoms. Objective. To report a case of primary hepatic angiosarcoma in an otherwise healthy man with normal liver function tests two months prior to presenting with a short period of jaundice that progressed to fulminant hepatic failure. Methods. Case report and review of literature. Conclusion. This case illustrates the rapidity of progression to death after the onset of symptoms in a patient with hepatic angiosarcoma. Research on early diagnostic strategies and newer therapies are needed to improve prognosis in this rare and poorly understood malignancy with limited treatment options.

  19. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  20. Frenuloplasty with a splitthicknes skin graft

    International Nuclear Information System (INIS)

    Mohammadi, G.; Nnaderpour, M.

    2006-01-01

    The purpose of this study was to investigate the severity of presenting symptomatology in patients with ankyloglossia and to assess the surgical results of patients undergoing frenuloplasty with split thickness skin graft. During a 4 year period from September 1998 through September 2002, 19 patients of ankyloglosia underwent frenuloplasty with a split thickness skin graft. All skin grafts were taken from arm. There were 11 males and 8 females. The average length of the lingual frenulum was 3.5 mm. Twelve children were over 4 years old and were primarily operated with this technique. In the 7 patients, Z plasty had been performed previously but failed and cicatrisation caused ankyloglosia. There were two minor postoperative complications, one hematoma, and other graft dehiscence with cicatrisation. The mobility of the tongue after one year was excellent. There were no complications in donor site. Frenuloplasty with split thickness skin graft is the best and easy procedure with good results for children over 4 years and those who fail primary closure. (author)

  1. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  2. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  3. Disease-specific hematopoietic stem cell transplantation in children with inherited bone marrow failure syndromes.

    Science.gov (United States)

    Li, Qian; Luo, Changying; Luo, Chengjuan; Wang, Jianmin; Li, Benshang; Ding, Lixia; Chen, Jing

    2017-08-01

    Hematopoietic stem cell transplantation (HSCT) using an optimized conditioning regimen is essential for the long-term survival of patients with inherited bone marrow failure syndromes (IBMFS). We report HSCT in 24 children with Fanconi anemia (FA, n = 12), Diamond-Blackfan anemia (DBA, n = 7), and dyskeratosis congenita (DC, n = 5) from a single HSCT center. The graft source was peripheral blood stem cells (n = 19) or cord blood stem cells (n = 5). FA and DC patients received reduced-intensity conditioning, while DBA patients had myeloablative conditioning. The median numbers of infused mononuclear cells and CD34+ cells were 14.20 × 10 8 /kg and 4.3 × 10 6 /kg, respectively. The median time for neutrophil and platelet recovery was 12 and 18 days, respectively. Complete donor engraftment was achieved in 23 of 24 patients. There was one primary graft failure. During a median follow-up of 27.5 months (range, 2-130 months), the overall survival in all patients was 95.8%. The incidence of grade II-III acute graft versus host disease (GvHD) and chronic GvHD was 29.2% and 16.7%, respectively. We conclude that HSCT can be a curative option for patients with IBMFS. Modification of the conditioning regimen based on the type of disease may lead to encouraging long-term outcomes.

  4. The effects of test environment and cyclic stretching on the failure properties of human patellar tendons

    International Nuclear Information System (INIS)

    Haut, R.C.; Powlison, A.C.

    1990-01-01

    There is a need to document the mechanical properties of patellar tendon allografts used for reconstructive surgery of the damaged anterior cruciate ligament, especially the effects of irradiation sterilization. The purpose of this study was to investigate the influences of in vitro test environment and low-level cyclic stretching prior to failure tests on nonirradiated and irradiated human graft tissues. Bilateral patellar tendons were split and each half processed accordingly. Some graft tissues were stretched cyclically at 2.5 mm deformation before failure. Experiments were performed in a 37 degrees C saline bath or with tissues moistened with a drip of the same. The irradiated grafts relaxed less and generated less slack length in the drip environment than the nonirradiated controls. Cyclic stretching did not alter failure characteristics of either graft tissue. While no significant differences in the tensile responses or failure characteristics were noted for irradiated and nonirradiated grafts in the drip, in the bath environment the nonirradiated tissues had greater strength and modulus. This resulted in there being a significant difference between irradiated and nonirradiated tissue responses in a heated saline bath environment. These experimental results exemplify the need to control in vitro test environments in the evaluation of various sterilization and preservation protocols for soft tissue allografts

  5. Post-transplant HLA class II antibodies and high soluble CD30 levels are independently associated with poor kidney graft survival.

    Science.gov (United States)

    Langan, L L; Park, L P; Hughes, T L; Irish, A; Luxton, G; Witt, C S; Christiansen, F T

    2007-04-01

    HLA-specific antibodies (HSA) and soluble CD30 (sCD30) were measured in 208 renal transplant recipients with functioning grafts at least 1 year after transplantation (median 8.2 years) to investigate the predictive value of HSA and sCD30 on subsequent graft outcome. HSA (class I and class II) were detected by both ELISA LAT-M and Luminex LabScreen assays. Data on graft outcome was collected with a median follow-up time of 3.5 years after antibody and sCD30 measurement. Recipients with post-transplant HLA class II antibodies had particularly poor graft outcome with a hazard ratio (HR) of 7.8 (p transplant sCD30 level >or=100 U/mL was associated with increased risk of subsequent graft failure (HR 2.7, p = 0.03). sCD30 and HSA had an independent and additive association with graft outcome. Recipients with HLA class II antibody and high sCD30 had the highest risk of subsequent graft failure (HR 43.4, p sCD30 measured at least 1-year post-transplant provides valuable and predictive information regarding subsequent graft outcome.

  6. Novel anterior cruciate ligament graft fixation device reduces slippage

    Directory of Open Access Journals (Sweden)

    Lopez MJ

    2013-05-01

    confirm that initial graft slippage is lower with GG versus BP extracortical hamstring graft tibial fixation. In addition, postoperative recovery and joint stability are more consistent with the GG. This information supports the GG as an alternative to extracortical tibial hamstring graft fixation that has procedural advantages over current implants and reduces graft failure from slippage.Keywords: cruciate, implant, bioabsorbable, canine, graft, tibia

  7. Palliative care among heart failure patients in primary care: a comparison to cancer patients using English family practice data.

    Directory of Open Access Journals (Sweden)

    Amy Gadoud

    Full Text Available Patients with heart failure have a significant symptom burden and other palliative care needs often over a longer period than patients with cancer. It is acknowledged that this need may be unmet but by how much has not been quantified in primary care data at the population level.This was the first use of Clinical Practice Research Datalink, the world's largest primary care database to explore recognition of the need for palliative care. Heart failure and cancer patients who had died in 2009 aged 18 or over and had at least one year of primary care records were identified. A palliative approach to care among patients with heart failure was compared to that among patients with cancer using entry onto a palliative care register as a marker for a palliative approach to care.Among patients with heart failure, 7% (234/3 122 were entered on the palliative care register compared to 48% (3 669/7 608 of cancer patients. Of heart failure patients on the palliative care register, 29% (69/234 were entered onto the register within a week of their death.This confirms that the stark inequity in recognition of palliative care needs for people with heart failure in a large primary care dataset. We recommend a move away from prognosis based criteria for palliative care towards a patient centred approach, with assessment of and attention to palliative needs including advance care planning throughout the disease trajectory.

  8. Budget impact analysis of heparin-bonded polytetrafluoroethylene grafts (Propaten) against standard polytetrafluoroethylene grafts for below-the-knee bypass in patients with critical limb ischaemia in France

    Science.gov (United States)

    Vergnaud, Simon; Riche, Valéry-Pierre; Tessier, Philippe; Mauduit, Nicolas; Kaladji, Adrien; Gouëffic, Yann

    2018-01-01

    Objectives To evaluate the budget impact of progressive replacement of standard polytetrafluoroethylene (PTFE) grafts by heparin-bound PTFE (Propaten) for below-the-knee (BTK) bypass in patients with critical limb ischaemia (CLI). Design From a review of the scientific literature, we calculated a theoretical BTK primary patency for Propaten grafts. Using the French hospital expenditure database (PMSI), we retrospectively estimated a rehospitalisation rate for standard PTFE grafts. From these data, a model was created to assess the budget impact of a progressive replacement from standard PTFE grafts to Propaten grafts over a 5-year horizon. We performed an univariate sensitivity analysis to assess the robustness of our results. Setting French National Health Insurance (FNHI) perspective. Participant Patients with CLI. Main outcome measures Budget impact analysis. Results Data extraction from the PMSI revealed that 656 patients were treated with PTFE grafts in 2011 in French public hospitals for a BTK bypass. Assuming a 2-year survival rate of 76.8%, observed reinterventions rate for standard PTFE grafts at 24 months from the PMSI was 35.1%. The mean rehospitalisation cost was €10 689. The budget impact analysis based on these data found a net cumulative 5-year payer budget reduction of €112 420 in favour of Propaten, under the assumption of a 75.6% primary patency for Propaten grafts for a projected population of 3215 patients of which 801 received a Propaten graft. Conclusions Our budget impact analysis showed a positive impact on the national health insurance budget of the replacement of standard PTFE grafts by Propaten grafts for BTK bypass in patients with CLI in France. This supports the enactment of a reimbursement policy by the FNHI. PMID:29490953

  9. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  10. A new design concept for knitted external vein-graft support mesh.

    Science.gov (United States)

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights

  11. Quantitative Evidence for Revising the Definition of Primary Graft Dysfunction after Lung Transplant.

    Science.gov (United States)

    Cantu, Edward; Diamond, Joshua M; Suzuki, Yoshikazu; Lasky, Jared; Schaufler, Christian; Lim, Brian; Shah, Rupal; Porteous, Mary; Lederer, David J; Kawut, Steven M; Palmer, Scott M; Snyder, Laurie D; Hartwig, Matthew G; Lama, Vibha N; Bhorade, Sangeeta; Bermudez, Christian; Crespo, Maria; McDyer, John; Wille, Keith; Orens, Jonathan; Shah, Pali D; Weinacker, Ann; Weill, David; Wilkes, David; Roe, David; Hage, Chadi; Ware, Lorraine B; Bellamy, Scarlett L; Christie, Jason D

    2018-01-15

    Primary graft dysfunction (PGD) is a form of acute lung injury that occurs after lung transplantation. The definition of PGD was standardized in 2005. Since that time, clinical practice has evolved, and this definition is increasingly used as a primary endpoint for clinical trials; therefore, validation is warranted. We sought to determine whether refinements to the 2005 consensus definition could further improve construct validity. Data from the Lung Transplant Outcomes Group multicenter cohort were used to compare variations on the PGD definition, including alternate oxygenation thresholds, inclusion of additional severity groups, and effects of procedure type and mechanical ventilation. Convergent and divergent validity were compared for mortality prediction and concurrent lung injury biomarker discrimination. A total of 1,179 subjects from 10 centers were enrolled from 2007 to 2012. Median length of follow-up was 4 years (interquartile range = 2.4-5.9). No mortality differences were noted between no PGD (grade 0) and mild PGD (grade 1). Significantly better mortality discrimination was evident for all definitions using later time points (48, 72, or 48-72 hours; P definition can be simplified by combining lower PGD grades. Construct validity of grading was present regardless of transplant procedure type or use of mechanical ventilation. Additional severity categories had minimal impact on mortality or biomarker discrimination.

  12. A comparison of patency and interventions in thigh versus Hemodialysis Reliable Outflow grafts for chronic hemodialysis vascular access.

    Science.gov (United States)

    Brownie, Evan R; Kensinger, Clark D; Feurer, Irene D; Moore, Derek E; Shaffer, David

    2016-11-01

    With improvements in medical management and survival of patients with end-stage renal disease, maintaining durable vascular access is increasingly challenging. This study compared primary, assisted primary, and secondary patency, and procedure-specific complications, and evaluated whether the number of interventions to maintain or restore patency differed between prosthetic femoral-femoral looped inguinal access (thigh) grafts and Hemodialysis Reliable Outflow (HeRO; Hemosphere Inc, Minneapolis, Minn) grafts. A single-center, retrospective, intention-to-treat analysis was conducted of consecutive thigh and HeRO grafts placed between May 2004 and June 2015. Medical history, interventions to maintain or restore patency, and complications were abstracted from the electronic medical record. Data were analyzed using parametric and nonparametric statistical tests, Kaplan-Meier survival methods, and multivariable proportional hazards regression and logistic regression. Seventy-six (43 thigh, 33 HeRO) grafts were placed in 61 patients (54% male; age 53 [standard deviation, 13] years). Median follow-up time in the intention-to-treat analysis was 21.2 months (min, 0.0; max, 85.3 months) for thigh grafts and 6.7 months (min, 0.0; max, 56.3 months) for HeRO grafts (P = .02). The groups were comparable for sex, age, coronary artery disease, diabetes mellitus, peripheral vascular disease, and smoking history (all P ≥ .12). One thigh graft (2%) and five HeRO (15%) grafts failed primarily. In the intention-to-treat analysis, patency durations were significantly longer in the thigh grafts (all log-rank P ≤ .01). Point estimates of primary patency at 6 months, 1 year, and 3 years were 61%, 46%, and 4% for the thigh grafts and 25%, 15%, and 6% for the HeRO grafts. Point estimates of assisted primary patency at 6 months, 1 year, and 3 years were 75%, 66%, and 54% for the thigh grafts and 41%, 30%, and 10% for the HeRO grafts. Point estimates of secondary patency at 6

  13. A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

    Directory of Open Access Journals (Sweden)

    Cem Inan Bektas

    2013-11-01

    Full Text Available BackgroundThe most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds.MethodsBetween March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm. First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion.ResultsThe mean follow-up was 7 months (range, 2-10 months in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent.ConclusionsIn our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

  14. Radiosensitivity of T and B lymphocytes. V. Effects of whole-body irradiation on numbers of recirculating T cells and sensitization to primary skin grafts in mice

    International Nuclear Information System (INIS)

    Anderson, R.E.; Williams, W.L.

    1977-01-01

    Whole-body exposure of mice to 50, 100, 300, or 500 rads results in an acute dose-related decrease in the number of viable recirculating T cells. The magnitude of this decrement becomes more pronounced with the passage of time. The dose-response relationship over this range of dosages appears to consist of three components: a steep drop between 0 and 50 rads, a plateau between 50 and 500 rads, and a second drop between 300 and 500 rads. The residual radioresistant cells are able to recognize a histoincompatible skin graft during the initial 5 days after irradiation. Low to moderate doses (50 to 300 rads) abrogate the partial tolerance noted in nonirradiated recipients exposed to the skin graft for 5 days and then regrafted from the same donor source 25 days after complete removal of the primary graft. A large (500 rads) dose results in prolonged graft survival in comparison with the nonirradiated group. It is suggested that the subpopulation of recirculating T cells which develops partial tolerance during a 5-day exposure to a homograft is more radiosensitive than the effector subpopulation which is involved in graft rejection

  15. Case report: Management of severe posterior open bite due to primary failure of eruption.

    LENUS (Irish Health Repository)

    Mc Cafferty, J

    2010-06-01

    Primary failure of tooth eruption (PFE) is a rare condition affecting any or all posterior quadrants. Unilateral involvement of maxillary and mandibular quadrants causes a dramatic posterior open bite that requires complex management strategies.

  16. A Review on Grafting of Biofibers for Biocomposites

    Directory of Open Access Journals (Sweden)

    Liqing Wei

    2016-04-01

    Full Text Available A recent increase in the use of biofibers as low-cost and renewable reinforcement for the polymer biocomposites has been seen globally. Biofibers are classified into: lignocellulosic fibers (i.e., cellulose, wood and natural fibers, nanocellulose (i.e., cellulose nanocrystals and cellulose nanofibrils, and bacterial cellulose, while polymer matrix materials can be petroleum based or bio-based. Green biocomposites can be produced using both biobased fibers and polymers. Incompatibility between the hydrophilic biofibers and hydrophobic polymer matrix can cause performance failure of resulting biocomposites. Diverse efforts have focused on the modification of biofibers in order to improve the performances of biocomposites. “Grafting” copolymerization strategy can render the advantages of biofiber and impart polymer properties onto it and the performance of biocomposites can be tuned through changing grafting parameters. This review presents a short overview of various “grafting” methods which can be directly or potentially employed to enhance the interaction between biofibers and a polymer matrix for biocomposites. Major grafting techniques, including ring opening polymerization, grafting via coupling agent and free radical induced grafting, have been discussed. Improved properties such as mechanical, thermal, and water resistance have provided grafted biocomposites with new opportunities for applications in specific industries.

  17. Failure by void coalescence in metallic materials containing primary and secondary voids subject to intense shearing

    DEFF Research Database (Denmark)

    Nielsen, Kim Lau; Tvergaard, Viggo

    2011-01-01

    Failure under intense shearing at close to zero stress triaxiality is widely observed for ductile metallic materials, and is identified in experiments as smeared-out dimples on the fracture surface. Numerical cell-model studies of equal sized voids have revealed that the mechanism governing...... this shear failure mode boils down to the interaction between primary voids which rotate and elongate until coalescence occurs under severe plastic deformation of the internal ligaments. The objective of this paper is to analyze this failure mechanism of primary voids and to study the effect of smaller...... secondary damage that co-exists with or nucleation in the ligaments between larger voids that coalesce during intense shearing. A numerical cell-model study is carried out to gain a parametric understanding of the overall material response for different initial conditions of the two void populations...

  18. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai [Department of Sports Medicine, Huashan Hospital, Shanghai (China); Zhang Pengyun; Wu Lingxiang [Shanghai Research Center of Biomedical Engineering, Shanghai (China); Chen Shiyi, E-mail: cshiyi@163.com [Department of Sports Medicine, Huashan Hospital, Shanghai (China)

    2011-09-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  19. Composite coating of 58S bioglass and hydroxyapatite on a poly (ethylene terepthalate) artificial ligament graft for the graft osseointegration in a bone tunnel

    International Nuclear Information System (INIS)

    Li Hong; Wu Yang; Ge Yunsheng; Jiang Jia; Gao Kai; Zhang Pengyun; Wu Lingxiang; Chen Shiyi

    2011-01-01

    The purpose of this study was to determine the effect of the combination of hydroxyapatite (HA) and bioglass (BG) on polyethylene terephthalate (PET) artificial ligament graft osseointegration within the bone tunnel. The results of in vitro culturing of MC3T3-E1 mouse osteoblastic cells proved that this HA/BG composite coating can promote the cell compatibility of grafts. A rabbit extraarticular tendon-to-bone healing model was used to evaluate the effect of this composite coating on PET artificial ligaments in vivo. The final results demonstrated that HA/BG coating improved new bone formation at the graft-bone interface and increased the load-to-failure property of graft in bone tunnel compared to the control group at early time. The study has shown that HA/BG composite coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.

  20. The empirical intensity of PWR primary coolant pumps failure and repair

    International Nuclear Information System (INIS)

    Milivojevicj, S.; Riznicj, J.

    1988-01-01

    The wealth of operating experience concerning PWR type and nuclear reactors that has been regularly monitored and systematically processes since 1971, enabled an analysis of the PWR primary coolant pumps operation. Failure intensity α and repair intensity μ of the pump during its working life were calculated, as these values are necessary in order to determine the reliability and availability of the pump as the basis for analyzing its effect on the safety and efficiency of the nuclear power plant. The trend of failure intensity α follows the theoretically expected changes in α over time, and this is around 10 -5 in the majority of life-time. Repair intensity μ indicates a slow rise during life-time, i.e. its faster return to operation. (author).7 refs.; 5 figs

  1. Classification and calculation of primary failure modes in bread production line

    International Nuclear Information System (INIS)

    Tsarouhas, Panagiotis H.

    2009-01-01

    In this study, we describe the classification methodology over a 2-year period of the primary failure modes in categories based on failure data of bread production line. We estimate the probabilities of these categories applying the chi-square goodness of fit test, and we calculate their joint probabilities of mass function at workstation and line level. Then, we present numerical examples in order to predict the causes and frequencies of breakdowns for workstations and for the entire bread production line that will occur in the future. The methodology is meant to guide bread and bakery product manufacturers, improving the operation of the production lines. It can also be a useful tool to maintenance engineers, who wish to analyze and improve the reliability and efficiency of the manufacturing systems

  2. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    Full Text Available Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8-30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG were excluded. Thus, out of 244 patients, 208 (85.3% untreated nonunion and 36 (14.7% following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN femoral head was found histologically in 135 (54.3% and radiologically in 48 (19.7% patients. The patients were operated by open reduction of fracture

  3. Simplified technique for auxiliary orthotopic liver transplantation using a whole graft

    Science.gov (United States)

    ROCHA-SANTOS, Vinicius; NACIF, Lucas Souto; PINHEIRO, Rafael Soares; DUCATTI, Liliana; ANDRAUS, Wellington; D'ALBURQUERQUE, Luiz Carneiro

    2015-01-01

    Background Acute liver failure is associated with a high mortality rate and the main purposes of treatment are to prevent cerebral edema and infections, which often are responsible for patient death. The orthotopic liver transplantation is the gold standard treatment and improves the 1-year survival. Aim To describe an alternative technique to auxiliary liver transplant on acute liver failure. Method Was performed whole auxiliary liver transplantation as an alternative technique for a partial auxiliary liver transplantation using a whole liver graft from a child removing the native right liver performed a right hepatectomy. The patient met the O´Grady´s criteria and the rational to indicate an auxiliary orthotopic liver transplantation was the acute classification without hemodynamic instability or renal failure in a patient with deterioration in consciousness. Results The procedure improved liver function and decreased intracranial hypertension in the postoperative period. Conclusion This technique can overcome some postoperative complications that are associated with partial grafts. As far as is known, this is the first case of auxiliary orthotopic liver transplantation in Brazil. PMID:26176253

  4. Modeling conduction in host-graft interactions between stem cell grafts and cardiomyocytes.

    Science.gov (United States)

    Chen, Michael Q; Yu, Jin; Whittington, R Hollis; Wu, Joseph C; Kovacs, Gregory T A; Giovangrandi, Laurent

    2009-01-01

    Cell therapy has recently made great strides towards aiding heart failure. However, while transplanted cells may electromechanically integrate into host tissue, there may not be a uniform propagation of a depolarization wave between the heterogeneous tissue boundaries. A model using microelectrode array technology that maps the electrical interactions between host and graft tissues in co-culture is presented and sheds light on the effects of having a mismatch of conduction properties at the boundary. Skeletal myoblasts co-cultured with cardiomyocytes demonstrated that conduction velocity significantly decreases at the boundary despite electromechanical coupling. In an attempt to improve the uniformity of conduction with host cells, differentiating human embryonic stem cells (hESC) were used in co-culture. Over the course of four to seven days, synchronous electrical activity was observed at the hESC boundary, implying differentiation and integration. Activity did not extend far past the boundary, and conduction velocity was significantly greater than that of the host tissue, implying the need for other external measures to properly match the conduction properties between host and graft tissue.

  5. Responsiveness of internal thoracic arteries to nitroglycerin in patients with renal failure.

    Science.gov (United States)

    Tawa, Masashi; Kinoshita, Takeshi; Asai, Tohru; Suzuki, Tomoaki; Ishibashi, Takaharu; Okamura, Tomio

    2017-12-11

    Nitroglycerin is commonly used as an antispasmodic for treating spasm of coronary artery bypass grafts. This study investigated whether the presence of renal failure affects reactivity to nitroglycerin in internal thoracic arteries obtained from patients undergoing coronary bypass surgery. The patients were divided into three groups according to estimated glomerular filtration rate (eGFR, mL/min/1.73 m 2 ): without renal failure (60 ≤ eGFR, n = 13), with moderate renal failure (30 ≤ eGFR renal failure (eGFR renal failure than in those without renal failure. In addition, there was a negative correlation between eGFR and the relaxant efficacy of nitroglycerin (P = 0.016). On the other hand, relaxant responses to BAY 60-2770 (which enhances cGMP generation as with nitroglycerin) were similar among three grades of renal function. An inverse relationship of eGFR to the relaxant efficacy of BAY 60-2770 was not observed, either (P = 0.314). These findings suggest that severe renal failure specifically potentiates nitroglycerin-induced relaxation in internal thoracic artery grafts.

  6. Management of recurrent anterior urethral strictures following buccal mucosal graft-urethroplasty: A single center experience.

    Science.gov (United States)

    Javali, Tarun Dilip; Katti, Amit; Nagaraj, Harohalli K

    2016-01-01

    To describe the safety, feasibility and outcome of redo buccal mucosal graft urethroplasty in patients presenting with recurrent anterior urethral stricture following previous failed BMG urethroplasty. This was a retrospective chart review of 21 patients with recurrent anterior urethral stricture after buccal mucosal graft urethroplasty, who underwent redo urethroplasty at our institute between January 2008 to January 2014. All patients underwent preoperative evaluation in the form of uroflowmetry, RGU, sonourethrogram and urethroscopy. Among patients with isolated bulbar urethral stricture, who had previously undergone ventral onlay, redo dorsal onlay BMG urethroplasty was done and vice versa (9+8 patients). Three patients, who had previously undergone Kulkarni-Barbagli urethroplasty, underwent dorsal free graft urethroplasty by ventral sagittal urethrotomy approach. One patient who had previously undergone urethroplasty by ASOPA technique underwent 2-stage Bracka repair. Catheter removal was done on 21(st) postoperative day. Follow-up consisted of uroflow, PVR and AUA-SS. Failure was defined as requirement of any post operative procedure. Idiopathic urethral strictures constituted the predominant etiology. Eleven patients presented with stricture recurrence involving the entire grafted area, while the remaining 10 patients had fibrotic ring like strictures at the proximal/distal graft-urethral anastomotic sites. The success rate of redo surgery was 85.7% at a mean follow-up of 41.8 months (range: 1 yr-6 yrs). Among the 18 patients who required no intervention during the follow-up period, the graft survival was longer compared to their initial time to failure. Redo buccal mucosal graft urethroplasty is safe and feasible with good intermediate term outcomes.

  7. Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope™

    Directory of Open Access Journals (Sweden)

    Takahisa Sasho

    2018-04-01

    Full Text Available In most anterior cruciate ligament (ACL reconstructions, grafts are fixed to the femoral side first followed by the tibial side. Various techniques have been reported to achieve optimal tension on the grafts, but once the grafts are fixed it is difficult to adjust graft tension further. To enable post fixation tension control we have invented a new graft configuration using an adjustable loop-device (TightRopeTM, Arthrex, FL, USA on the tibial side. In this paper, biomechanical properties of this configuration using soft tissue were examined in terms of graft diameter and various suture techniques (referred to as base suture to make a closed circle to support TightRopeTM.Two experiments were conducted under different conditions. In each experiment, cyclic load, followed by a pull-to-failure load, was applied to the grafts and elongation and failure mode were recorded. (1 To evaluate the effects of diameter, 5.0 or 6.0 mm grafts were prepared by a single locking loop stitch as the base suture (SLL5, SLL6. (2 To evaluate different base sutures, 5.0 mm tendons were used, and grafts were prepared using five kinds of base sutures (SLL, ZLL: zigzag locking loop, DZLL: double zigzag locking loop, DK: double Krackow, DK w/o TR: double Krackow without TightRopeTM. In the first experiment, tearing was observed in 2 of 6 cases in the SLL5 test group, whereas no tearing was observed with SLL6. In the second experiment, no tearing was observed with DZLL or DK. Elongation was smaller in these two groups compared to the other groups. Mechanical strength decreases with a smaller graft diameter. Biomechanical properties differed with different base sutures and, among them, the double-zigzag-suture stitch and double Krackow provided less elongation and higher ultimate load in this graft configuration.

  8. Management of an irradiated anophthalmic socket following dermis-fat graft rejection: A case report

    Directory of Open Access Journals (Sweden)

    Raizada Kuldeep

    2008-01-01

    Full Text Available Dermis-fat graft (DFG is often the only promising option in cases of severely contracted sockets. However, there is an increased risk of graft failure in irradiated sockets with decreased vascularity. In such difficult cases, repeat DFG implantation also has higher risks of graft failure. We describe an ingenious method of successful management of an irradiated anophthalmic socket following DFG infection and necrosis, with acceptable cosmetic results. At surgery, an orbital impression was taken with ophthalmic grade alginate. Based on this measurement, a custom-made stem pressure socket-expander made up of high density polymethyl methacrylate (PMMA was fitted, a week post surgery and kept in situ for six weeks. On review, the fornices had considerably deepened. The expander device was removed and the patient was now fitted with a custom-made thicker prosthesis made up of high-density PMMA. The patient has followed up for a year subsequently and the prosthesis has remained stable.

  9. A Kidney Graft Survival Calculator that Accounts for Mismatches in Age, Sex, HLA, and Body Size.

    Science.gov (United States)

    Ashby, Valarie B; Leichtman, Alan B; Rees, Michael A; Song, Peter X-K; Bray, Mathieu; Wang, Wen; Kalbfleisch, John D

    2017-07-07

    Outcomes for transplants from living unrelated donors are of particular interest in kidney paired donation (KPD) programs where exchanges can be arranged between incompatible donor-recipient pairs or chains created from nondirected/altruistic donors. Using Scientific Registry of Transplant Recipients data, we analyzed 232,705 recipients of kidney-alone transplants from 1998 to 2012. Graft failure rates were estimated using Cox models for recipients of kidney transplants from living unrelated, living related, and deceased donors. Models were adjusted for year of transplant and donor and recipient characteristics, with particular attention to mismatches in age, sex, human leukocyte antigens (HLA), body size, and weight. The dependence of graft failure on increasing donor age was less pronounced for living-donor than for deceased-donor transplants. Male donor-to-male recipient transplants had lower graft failure, particularly better than female to male (5%-13% lower risk). HLA mismatch was important in all donor types. Obesity of both the recipient (8%-18% higher risk) and donor (5%-11% higher risk) was associated with higher graft loss, as were donor-recipient weight ratios of transplants where both parties were of similar weight (9%-12% higher risk). These models are used to create a calculator of estimated graft survival for living donors. This calculator provides useful information to donors, candidates, and physicians of estimated outcomes and potentially in allowing candidates to choose among several living donors. It may also help inform candidates with compatible donors on the advisability of joining a KPD program. Copyright © 2017 by the American Society of Nephrology.

  10. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  11. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  12. Prognosis of Dialysed Patients after Kidney Transplant Failure

    Directory of Open Access Journals (Sweden)

    Réka P. Szabó

    2013-05-01

    Full Text Available Background/Aims: Patients with a failed kidney transplant represent a unique, high-risk chronic kidney disease population that is increasing in number, and may be sub-optimally managed. Our aim was to compare the survival of patients with failed allografts to patients with native kidney failure and to assess whether their survival is affected by the graft resection. Methods: Kaplan-Meier and Cox-regression survival analyses were performed on the data of 57 patients with graft failure and of 123 transplant-naive haemodialysed patients. Results: After adjustment for age and gender, there was no statistically significant difference in the mortality of patients in the two groups. The 43 patients, who had a transplanted kidney nephrectomy had a statistically not significant survival benefit over non-nephrectomised patients (age and gender adjusted hazard ratio: 0.56 95 % confidence interval: 0.24-1.58, p-value: 0.18. Conclusion: Elective graft resection is a safe, effective alternative for both the treatment and the prevention of the chronic inflammatory state associated with a failed kidney transplant.

  13. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  14. Decreased graft survival in liver transplant recipients of donors with positive blood cultures: a review of the United Network for Organ Sharing dataset.

    Science.gov (United States)

    Huaman, Moises A; Vilchez, Valery; Mei, Xiaonan; Shah, Malay B; Daily, Michael F; Berger, Jonathan; Gedaly, Roberto

    2017-06-01

    Liver transplantation using blood culture positive donors (BCPD) has allowed a significant expansion of the donor pool. We aimed to characterize BCPD and assess the outcomes of BCPD liver transplant recipients. We retrieved data from the United Network for Organ Sharing (UNOS) registry on all adults who underwent primary, single-organ deceased-donor liver transplantation in the USA between 2008 and 2013. Patients were classified into two cohorts: the BCPD cohort and the non-BCPD cohort. One-year graft and patient survival were compared between cohorts using Kaplan-Meier estimates and Cox models. A total of 28 961 patients were included. There were 2316 (8.0%) recipients of BCPD. BCPD were more likely to be older, female, black, diabetic, hypertensive, and obese compared to non-BCPD. Graft survival was significantly lower in BCPD recipients compared to non-BCPD recipients (Kaplan-Meier, 0.85 vs. 0.87; P = 0.009). Results remained significant in propensity-matched analysis (P = 0.038). BCPD was independently associated with decreased graft survival (adjusted HR; 1.10, 95% CI 1.01-1.20; P = 0.04). There were no significant differences in patient survival between study groups. BCPD was associated with decreased graft survival in liver transplant recipients. Studies are needed to identify subgroups of BCPD with the highest risk of graft failure and characterize the underlying pathogenic mechanisms. © 2016 Steunstichting ESOT.

  15. Telomere shortening in hematopoietic stem cell transplantation: a potential mechanism for late graft failure?

    Science.gov (United States)

    Awaya, Norihiro; Baerlocher, Gabriela M; Manley, Thomas J; Sanders, Jean E; Mielcarek, Marco; Torok-Storb, Beverly; Lansdorp, Peter M

    2002-01-01

    Telomeres serve to maintain the structural integrity of chromosomes, yet each somatic cell division is associated with a decrease in telomere length. The cumulative decrease in telomere length can impose an upper limit for the number of cell divisions that can occur before a cell senesces. When studied in vitro with fibroblasts, this limit is referred to as the Hayflick limit and usually occurs after 40 to 80 cell doublings. In theory, a similar replicative potential in a hematopoietic stem cell could support hematopoiesis in a person for more than 100 years. However, stem cells differentiate, and the telomere length differs among chromosomes within a single cell, among cell types, and among age-matched individuals. This variation in telomere length raises the possibility that long-term hematopoiesis by transplanted stem cells could, depending on the telomere length of the engrafted stem cell and the proliferative demand to which it is subjected, reach a Hayflick limit during the life span of the patient. Although significant shortening of telomeres is reported to occur within the first year posttransplantation, as yet no evidence has indicated that this shortening is associated with marrow function. In this review, we summarize reports on telomere shortening in stem cell transplantation recipients and report 2 cases in which graft failure is associated with significant telomere shortening.

  16. Balloon expandable intraluminal grafting of normal and abnormal renal arteries: Experimental study

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Hayashi, H.; Schatz, R.; Hunter, G.; Tio, F.O.; Garcia, O.

    1986-01-01

    Balloon expandable intraluminal grafts were placed in renal arteries of eight adult dogs and 11 minipigs. The renal arteries were normal in the dogs before graft placement. Two grafts were placed in primary division branches and the rest in the main renal artery. Experimental renal artery stenosis was created in the minipigs by subocclusive ligature of the renal artery with absorbable suture material. Six months later significant renal artery stenoses developed in six pigs and were corrected by graft placement. In the remaining pigs grafts were placed in the opposite normal renal artery because the stenosis caused a small, shrunken kidney in two, and severe spasm or anatomic variations prevented graft placement in three. All grafts remained patent on angiographic and pathologic examinations to a maximum follow-up to 24 weeks

  17. Genome-wide identification and comparative analysis of grafting-responsive mRNA in watermelon grafted onto bottle gourd and squash rootstocks by high-throughput sequencing.

    Science.gov (United States)

    Liu, Na; Yang, Jinghua; Fu, Xinxing; Zhang, Li; Tang, Kai; Guy, Kateta Malangisha; Hu, Zhongyuan; Guo, Shaogui; Xu, Yong; Zhang, Mingfang

    2016-04-01

    Grafting is an important agricultural technique widely used to improve plant growth, yield, and adaptation to either biotic or abiotic stresses. However, the molecular mechanisms underlying grafting-induced physiological processes remain unclear. Watermelon (Citrullus lanatus L.) is an important horticultural crop worldwide. Grafting technique is commonly used in watermelon production for improving its tolerance to stresses, especially to the soil-borne fusarium wilt disease. In the present study, we used high-throughput sequencing to perform a genome-wide transcript analysis of scions from watermelon grafted onto bottle gourd and squash rootstocks. Our transcriptome and digital gene expression (DGE) profiling data provided insights into the molecular aspects of gene regulation in grafted watermelon. Compared with self-grafted watermelon, there were 787 and 3485 genes differentially expressed in watermelon grafted onto bottle gourd and squash rootstocks, respectively. These genes were associated with primary and secondary metabolism, hormone signaling, transcription factors, transporters, and response to stimuli. Grafting led to changes in expression of these genes, suggesting that they may play important roles in mediating the physiological processes of grafted seedlings. The potential roles of the grafting-responsive mRNAs in diverse biological and metabolic processes were discussed. Obviously, the data obtained in this study provide an excellent resource for unraveling the mechanisms of candidate genes function in diverse biological processes and in environmental adaptation in a graft system.

  18. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  19. Patterns of local-regional failure after primary intensity modulated radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Kong, Fangfang; Ying, Hongmei; Du, Chengrun; Huang, Shuang; Zhou, Junjun; Chen, Junchao; Sun, Lining; Chen, Xiaohui; Hu, Chaosu

    2014-01-01

    To analyze patterns of local-regional failure after primary intensity modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). A total of 370 non-metastatic NPC patients consecutively treated with IMRT (with or without chemotherapy) were analyzed. Radiotherapy was administered using a simultaneous integrated boost (SIB) technique at the total prescribed dose of 66-70.4Gy (2.0-2.2Gy per fraction). The location and extent of local-regional failures were transferred to the pretreatment planning computed tomography (CT) for dosimetric analysis. The dose of radiation received by V recur (volume of recurrence) was calculated and analyzed with dose-volume histogram (DVH). Failures were classified as: 'in field' if 95% of V recur was within the 95% isodose, 'marginal' if 20% to 95% of V recur was within the 95% isodose, or 'outside' if less than 20% of V recur was inside the 95% isodose. With a median follow up of 26 months, 25 local-regional failures were found in 18 patients. The 1- and 2-year actuarial local-regional control rates for all patients were 99.7% and 95.5% respectively. Among the 22 local–regional failures with available diagnostic images, 16 (64%) occurred within the 95% isodose lines and were considered in-field failures; 3 (12%) were marginal and 3 (12%) were outside-field failures. Intensity-modulated radiotherapy provides excellent local-regional control for NPC. In-field failures are the main patterns for local-regional recurrence. Reducing the coverage of critical adjacent tissues in CTV purposefully for potential subclinical diseases was worth of study. Great attention in all IMRT steps is necessary to reduce potential causes of marginal failures. More studies about radioresistance are needed to reduce in-field failures

  20. A Bone Graft Substitutes Hydroxyapatite Coated Gentamycin (Bonigent) As Drug Delivery System

    International Nuclear Information System (INIS)

    Rusnah Mustaffa; Fauziah Othman; Asmah Rahmat; Mohd Reusmaazran Yusof; Shaaban Kasim; Narimah Abu Baka; Nasani Nasrul

    2014-01-01

    Porous hydroxyapatite coated with antibiotic gentamycin for drug delivery system is namely Bonigent. In this product, antibiotic (gentamycin) is coated into the scaffolds HA porous and Would then be released slowly into the bone tissue upon implantation, this way would increase drug penetration, thus avoiding systemic infection, preventing the formation of biofilm and improved healing. When a foreign material (implants or scaffolds of bone graft substitutes) is introduced into the body, there would be normally formation of biofilm that can lead to systemic infection and cause device failure. Surgeon will use antibiotic such as gentamycin to avoid these effects. The purpose of this project is to investigate the feasibility of fabricating a drug delivery system (DDS) that serves dual functions, to combating biofilms and to enhance bone in growths. We also successfully producing a scaffold HA bone graft substitutes incorporated with antibiotic gentamycin to combating bio-film and prevent the failure medical device implant for healthy and human nation. Bone graft substitutes into porous scaffolds suitable for drug delivery; loading the scaffolds with gentamycin; and study release rate in vivo were studied. Porous bone grafts substitutes are coated with antibiotic gentamycin by immerse technique. In order to limit biofilm formation, biomaterials loaded with suitable antibiotics can be used as a preventative measure. The biomaterials hydroxyapatite (HA) is an osteoconductive space filler and is produced locally by Malaysian Nuclear Agency. Porous HA and HA/ TCP has the potential to be used as synthetic bone graft materials because it is bioactive and biocompatible with bone tissues. Development of a product as bone graft substitute (BGS) with special ability of delivering drug (gentamycin) to bone tissue for better and more effective healing process. Characterization of the physical analysis, porosity, surface morphology by Scanning Electron Microscopy Analysis (SEM) and

  1. The prognostic importance of heart failure and age in patients treated with primary angioplasty

    NARCIS (Netherlands)

    Henriques, Jose P. S.; Zijlstra, Felix; de Boer, Menko-Jan; van 't Hof, Arnoud W. J.; Gosselink, A. T. Marcel; Dambrink, Jan-Henk E.; Suryapranata, Harry; Hoorntje, Jan C. A.

    2003-01-01

    Effective risk stratification is essential in the management of patients with acute myocardial infarction. Available models have not yet been studied and validated in patients treated with primary angioplasty for acute myocardial infarction. The prognostic value of heart failure defined by Killip

  2. Renal failure due to primary amyloidosis: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Ramon Andrade Bezerra de Mello

    Full Text Available CONTEXT: Primary amyloidosis, also known as AL amyloidosis, is commonly caused by clonal expansion of plasma cells in the bone marrow, thereby segregating light chains of clonal immunoglobulin that settle in tissues in the form of insoluble amyloid fibrils. The aim of this study was to report a case of primary amyloidosis with renal failure, diagnosed in Hospital São João, Porto, Portugal, focusing on the diagnostic difficulties and presenting a literature review. CASE REPORT: A 68-year-old Caucasian man was admitted to the Internal Medicine Department of the hospital with a condition of anasarca and nephrotic syndrome. After performing a renal biopsy that tested positive using Congo red and immunohistochemistry, lambda light chain amyloidosis was diagnosed. This evolved into terminal renal disease, which led to hemodialysis and several episodes of urinary and catheter infections. He was started on chemotherapy, consisting of bortezomib 0.7 mg/m² and dexamethasone 40 mg in six cycles. This led to clinical improvement, stabilization of the illness and good tolerance of the treatment. CONCLUSION: Amyloidosis is a rare entity that is difficult to diagnose. This is because of the unspecific early clinical manifestations of the disease. The hypothesis of amyloidosis is only considered when specific organ failure occurs. This case consisted of primary amyloidosis with involvement of the kidneys as an initial presentation of the disease and its difficulties were shown, going from the clinical approach to the final diagnosis.

  3. Resistance profiles and adherence at primary virological failure in three different highly active antiretroviral therapy regimens: analysis of failure rates in a randomized study

    DEFF Research Database (Denmark)

    Røge, B T; Barfod, T S; Kirk, O

    2004-01-01

    OBJECTIVES: To investigate the interplay between resistance and adherence in the virological failure of three fundamentally different highly active antiretroviral therapy (HAART) regimens. METHODS: We retrospectively identified 56 verified primary virological failures (viral load >400 HIV-1 RNA...... copies/mL) among 293 patients randomized to two nucleoside reverse transcriptase inhibitors (NRTIs)+ritonavir+saquinavir (RS-arm) (n=115), two NRTIs+nevirapine+nelfinavir (NN-arm) (n=118), or abacavir+stavudine+didanosine (ASD-arm) (n=60) followed up for a median of 90 weeks. Data on adherence were...... collected from patient files, and genotyping was performed on plasma samples collected at time of failure. RESULTS: Treatment interruption or poor adherence was mainly caused by side effects and accounted for 74% of failures, and was associated with absence of resistance mutations. In the 30 failing...

  4. Early prophylactic autogenous bone grafting in type III open tibial fractures.

    Science.gov (United States)

    Kesemenli, Cumhur C; Kapukaya, Ahmet; Subaşi, Mehmet; Arslan, Huseyin; Necmioğlu, Serdar; Kayikçi, Cuma

    2004-08-01

    The authors report the results achieved in patients with type III open tibial fractures who underwent primary autogenous bone grafting at the time of debridement and skeletal stabilisation. Twenty patients with a mean age of 35.8 years (range, 24-55) were treated between 1996 and 1999. Eight fractures were type IIIA, 11 were type IIIB, and 1 was type IIIC. At the index procedure, wound debridement, external fixation and autogenous bone grafting with bone coverage were achieved. The mean follow-up period was 46 months (range, 34-55). The mean time to fixator removal was 21 weeks (range, 14-35), and the mean time to union was 28 weeks (range, 19-45). Skin coverage was achieved by a myocutaneous flap in 2 patients, late primary closure in 4, and split skin grafting in 14. One (5%) of the patients experienced delayed union, and 1 (5%) developed infection. In tibial type III open fractures, skin coverage may be delayed, using the surrounding soft tissue to cover any exposed bone after thorough débridement and wound cleansing. Primary prophylactic bone grafting performed at the same time reduces the rate of delayed union, shortens the time to union, and does not increase the infection rate.

  5. Feasibility and Advantages of Full Thickness Skin Graft from the Anterolateral Thigh.

    Science.gov (United States)

    Shin, Seung-Han; Kim, Chulkyu; Lee, Yong-Suk; Kang, Jin-Woo; Chung, Yang-Guk

    2017-12-01

    Full thickness skin graft (FTSG) gives better outcomes than split thickness skin graft (STSG), but it has the drawback of limited donor sites. Anterolateral thigh (ALT), a popular donor site of STSG, is also a popular donor site of perforator flaps. This area has the advantage of large flap size available with primary closure. Based on this we harvested FTSG instead of STSG from the ALT. We retrospectively reviewed 10 cases of FTSG from the ALT, with the recipient site of foot in 3, ankle in 2, lower leg in 2, forearm in 2, and wrist in 1 patient. In all cases elliptical full thickness skin was harvested from the ALT, and the donor site was closed primarily. The skin was defatted and placed onto the defect with vacuum-assisted closure (VAC). The skin size ranged 7-30 cm in length and 3-12 cm in width. Mean follow up period was 7 months (range, 3-13). FTSG from the ALT provided durable wound coverage, with excellent color and texture matching. Partial (< 20%) graft failure was observed in 1 case, but no additional surgery was necessary. No patient reported donor site pain at postoperative 2 weeks. No donor site complications were encountered. No patient complained a feeling of tension in the thigh at final follow-up. FTSG from the ALT is feasible with the aid of VAC. Considering the skin quality, large skin size available, early pain relief, and little donor site morbidity, the ALT should be revisited as a donor site of FTSG.

  6. CHALLENGES IN TREATMENT OF RENAL GRAFT ACUTE ANTIBODY-MEDIATED REJECTION

    Directory of Open Access Journals (Sweden)

    A. I. Sushkov

    2016-01-01

    Full Text Available Diagnostic criteria and treatment protocols for acute antibody-mediated rejection (AMR of kidney allograft remain controversial. We report the case of early severe AMR after primary kidney transplantation. The graft removal was considered in the absence of treatment efficacy and in the presence of systemic infl ammatory response syndrome. However, at surgery the graft looked normal and it was not removed. The repeated treatment course (plasmapheresis, antithymocyte globulin, intravenous immunoglobulin and rituximab was effective. The patient has good and stable graft function in 1 year after transplantation. 

  7. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    Science.gov (United States)

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  8. Primary Nonfunction of Renal Allograft Secondary to Acute Oxalate Nephropathy

    Directory of Open Access Journals (Sweden)

    Ravi Parasuraman

    2011-01-01

    Full Text Available Primary nonfunction (PNF accounts for 0.6 to 8% of renal allograft failure, and the focus on causes of PNF has changed from rejection to other causes. Calcium oxalate (CaOx deposition is common in early allograft biopsies, and it contributes in moderate intensity to higher incidence of acute tubular necrosis and poor graft survival. A-49-year old male with ESRD secondary to polycystic kidney disease underwent extended criteria donor kidney transplantation. Posttransplant, patient developed delayed graft function (DGF, and the biopsy showed moderately intense CaOx deposition that persisted on subsequent biopsies for 16 weeks, eventually resulting in PNF. The serum oxalate level was 3 times more than normal at 85 μmol/L (normal <27 μmol/L. Allograft nephrectomy showed massive aggregates of CaOx crystal deposition in renal collecting system. In conclusion, acute oxalate nephropathy should be considered in the differential diagnosis of DGF since optimal management could change the outcome of the allograft.

  9. Local full-thickness skin graft of the donor arm--a novel technique for the reduction of donor site morbidity in radial forearm free flap.

    Science.gov (United States)

    Riecke, B; Assaf, A T; Heiland, M; Al-Dam, A; Gröbe, A; Blessmann, M; Wikner, J

    2015-08-01

    A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Donor Diabetes and Prolonged Cold Ischemia Time Synergistically Increase the Risk of Graft Failure After Liver Transplantation

    NARCIS (Netherlands)

    Brüggenwirth, Isabel M A; Dolgin, Natasha H; Porte, Robert J; Bozorgzadeh, Adel; Martins, Paulo N A

    BACKGROUND: Both prolonged cold ischemia time (CIT) and donor history of diabetes mellitus (DM) are associated with reduced graft survival after liver transplantation. However, it is unknown whether the adverse effect of prolonged CIT on posttransplant graft survival is more pronounced after

  11. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  12. Reconstruction of mandibular defects with autogenous bone grafts: a review of 30 cases

    International Nuclear Information System (INIS)

    Sajid, M.A.; Warraich, R.A.; Abid, H.; Haq, M.E.; Shah, K.L.; Khan, Z.

    2012-01-01

    Multitudes of options are available for reconstruction of functional and cosmetic defects of the mandible, caused by various ailments. At the present time, autogenous bone grafting is the gold standard by which all other techniques of reconstruction of the mandible can be judged. The purpose of this study was to evaluate the outcome of different osseous reconstruction options using autogenous bone grafts for mandibular reconstruction. Methods: This Interventional study was conducted at Department of Oral and Maxillofacial Surgery, King Edward Medical University/Mayo Hospital Lahore, from January 2008 to July 2009 including one year follow-up. The study was carried out on thirty patients having bony mandibular defects. They were reconstructed with the autogenous bone grafts from different graft donor sites. On post-operative visits they were evaluated for outcome variables. Results: Success rate of autogenous bone grafts in this study was 90%. Only 10% of the cases showed poor results regarding infection, resorption and graft failure. Conclusion: Autogenous bone grafts, non-vascularized or vascularized, are a reliable treatment modality for the reconstruction of the bony mandibular defects with predictable functional and aesthetic outcome. (author)

  13. Evolution of skin grafting for treatment of burns: Reverdin pinch grafting to Tanner mesh grafting and beyond.

    Science.gov (United States)

    Singh, Mansher; Nuutila, Kristo; Collins, K C; Huang, Anne

    2017-09-01

    Skin grafting is the current standard care in the treatment of full thickness burns. It was first described around 1500 BC but the vast majority of advancements have been achieved over the past 200 years. An extensive literature review was conducted on Pubmed, Medline and Google Scholar researching the evolution of skin grafting techniques. The authors concentrated on the major landmarks of skin grafting and also provide an overview of ongoing research efforts in this field. The major innovations of skin grafting include Reverdin pinch grafting, Ollier grafting, Thiersch grafting, Wolfe grafting, Padgett dermatome and modifications, Meek-wall microdermatome and Tanner mesh grafting. A brief description of the usage, advantages and limitations of each technique is included in the manuscript. Skin grafting technique have evolved significantly over past 200 years from Reverdin pinch grafting to modern day meshed skin grafts using powered dermatome. Increasing the expansion ratio and improving the cosmetic and functional outcome are the main focus of ongoing skin grafting research and emerging techniques (such as Integra ® , Recell ® , Xpansion ® ) are showing promise. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  14. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  15. Punch grafts to treat lower limb intractable sores

    Directory of Open Access Journals (Sweden)

    JÚLIO WILSON FERNANDES

    Full Text Available ABSTRACT Lower limb recurrent ulcers, usually caused by prolonged decubitus, trauma, diabetes or burns, may not heal with conventional clinical or surgical treatment. Frequently, laminated skin grafts do not integrate with the recipient layer, and the only alternatives are neighbor microsurgical flaps. These have higher morbidity and create secondary defects, to be corrected with skin grafts, when fasciocutaneous or miocutaneous segments are removed for the treatment of the primary defect. We describe the non-conventional use of punch grafts in the treatment of lower limb ulcers, when conventional skin laminated graft failed, without the use of flaps. Since this is a very successful technique, its use should be considered as a valuable alternative for the treatment of recurrent lower limb ulcers. It is a simple and easy-learned technique that may be used by different surgeons, even in remote places without correct specialized hospital facilities.

  16. Metalloproteinase Expression is Associated with Traumatic Wound Failure

    Science.gov (United States)

    2010-04-01

    Traumatic amputation- no.(%) 15 Size of wound (cm3 )* Associated vascular injury- no.(%) 7 Wound closure method no.(%) Suture 29 Skin graft 9 Number...definitive closure or coverage with skin graft . Im- paired wound healing included delayed wound closure or wound dehiscence after closure or coverage...closure time period of 10 d. Dehiscence was defined as spontaneous partial or com- plete wound disruption after primary closure or > 90% skin graft loss

  17. Acute adrenal failure as the presenting feature of primary antiphospholipid syndrome in a child

    Directory of Open Access Journals (Sweden)

    Improda Nicola

    2012-09-01

    Full Text Available Abstract Introduction Antiphospholipid syndrome (APS is characterized by recurrent arterial and venous thrombosis and detection of antiphospholipid antibodies (aPLs. This syndrome may be associated with connective tissue disorders, or with malignancies, but it may also appear in isolated form (primary APS. We report on a pediatric patient presenting with acute adrenal failure as the first manifestation of primary APS. Case report A previously healthy 11-year-old boy developed fever, abdominal pain, and vomiting. An abdominal computed tomography scan showed nodular lesions in the adrenal glands. He was referred to our Department and a diagnosis of APS and acute adrenal failure was considered, based on positive aPLs (IgG and IgM, elevated ACTH levels and low cortisol levels. Other features were anemia, thrombocytopenia, elevated inflammatory parameters, hypergammaglobulinemia, prolonged partial thromboplastin time, positive antinuclear, anticardiolipin, anti-platelet antibodies, with negative double-stranded DNA antibodies. Lupus anticoagulant and Coomb’s tests were positive. MRI revealed a bilateral adrenal hemorrhage. A treatment with intravenous metylprednisolone, followed by oral prednisone and anticoagulant, was started, resulting in a progressive improvement. After 2 months he also showed hyponatremia and elevated renine levels, indicating a mineralcocorticoid deficiency, requiring fludrocortisones therapy. Conclusion The development of acute adrenal failure from bilateral adrenal haemorrhage in the context of APS is a rare but life-threatening event that should be promptly recognized and treated. Moreover, this case emphasizes the importance of the assessment of aPLs in patients with acute adrenal failure in the context of an autoreaction.

  18. [Repair of fingertip amputations using composite grafts: nine clinical cases].

    Science.gov (United States)

    Al Saflan, A; May, P; Revol, M; Servant, J-M

    2010-08-01

    Even if a digital replantation is not possible, we present a series of nine cases of fingertip amputations treated with clinical efficacy by using a composite graft from the amputated finger part. All of our eight patients (four children and four adults) were traumatically amputated. The level of amputation passed by the bunch of P3 and carried partially or completely the ungula. The reposition was always performed under local anaesthesia. Our evaluation related on the survival of the composite grafts, the functional and the aesthetic result. The composite grafts were revascularised in eight amputations out of nine, with a satisfactory remote result on the function as well as aesthetic level. After a short recall of the alternative surgical methods of the treatment of the fingertip amputations, we will insist on the simplicity and the reliability of the repositioning of a composite graft, recommended for us from the start and depending on the traumatic level. In the event of a failure, surgeons still have the possibility of realising the other alternative surgical methods. 2009. Published by Elsevier SAS.

  19. What causes treatment failure - the patient, primary care, secondary care or inadequate interaction in the health services?

    Directory of Open Access Journals (Sweden)

    Lange Ove

    2011-05-01

    Full Text Available Abstract Background Optimal treatment gives complete relief of symptoms of many disorders. But even if such treatment is available, some patients have persisting complaints. One disorder, from which the patients should achieve complete relief of symptoms with medical or surgical treatment, is gastroesophageal reflux disease (GERD. Despite the fact that such treatment is cheap, safe and easily available; some patients have persistent complaints after contact with the health services. This study evaluates the causes of treatment failure. Methods Twelve patients with GERD and persistent complaints had a semi-structured interview which focused on the patients' evaluation of treatment failure. The interviews were taped, transcribed and evaluated by 18 physicians, (six general practitioners, six gastroenterologists and six gastrointestinal surgeons who completed a questionnaire for each patient. The questionnaires were scored, and the relative responsibility for the failure was attributed to the patient, primary care, secondary care and interaction in the health services. Results Failing interaction in the health services was the most important cause of treatment failure, followed by failure in primary care, secondary care and the patient himself; the relative responsibilities were 35%, 28%, 27% and 10% respectively. There was satisfactory agreement about the causes between doctors with different specialities, but significant inter-individual differences between the doctors. The causes of the failures differed between the patients. Conclusions Treatment failure is a complex problem. Inadequate interaction in the health services seems to be important. Improved communication between parts of the health services and with the patients are areas of improvement.

  20. Embryonic kidney function in a chronic renal failure model in rodents.

    Science.gov (United States)

    Fujimoto, Eisuke; Yamanaka, Shuichiro; Kurihara, Sho; Tajiri, Susumu; Izuhara, Luna; Katsuoka, Yuichi; Yokote, Shinya; Matsumoto, Kei; Kobayashi, Eiji; Okano, Hirotaka James; Chikaraishi, Tatsuya; Yokoo, Takashi

    2017-08-01

    Rapid advancements have been made in alternative treatments for renal diseases. Our goal for renal regeneration is to establish a kidney graft derived from human embryonic tissues. In this study, we investigated the effects of host renal failure on the structure and activity of transplanted embryonic kidney and bladder, and found that diuretics effectively induced urine production in the transplanted kidney. Uremic conditions were reproduced using a 5/6 renal infarction rat model. An embryonic kidney plus bladder (embryonic day 15) was isolated from a pregnant Lewis rat and transplanted into the para-aortic area of a 5/6 renal-infarcted Lewis rat. Following growth, the embryonic bladder was successfully anastomosed to the host ureter. We assessed graft function in terms of survival rates and found no differences between normal (n = 5) and renal failure (n = 8) groups (median survival: 70.5 vs 74.5 h; p = 0.331) in terms of survival, indicating that the grafts prolonged rat survival, even under renal failure conditions. Furosemide (n = 9) significantly increased urine volume compared with saline-treated controls (n = 7; p < 0.05), confirming that the grafts were functional. We also demonstrated the possibilities of an in vivo imaging system for determining the viability of transplanted embryonic kidney with bladder. The results of this study demonstrate that transplanted embryonic kidney and bladder can grow and function effectively, even under uremic conditions.

  1. Infrascrotal, perineal, femorofemoral bypass for arterial graft infection at the groin.

    Science.gov (United States)

    Illuminati, Giulo; Caliò, Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2004-12-01

    Infrascrotal, perineal, femorofemoral bypass is an acceptable procedure for treating infection of a prosthetic arterial graft limited to a unilateral groin. A consecutive sample clinical study with a mean follow-up of 29 months. The surgical department of an academic tertiary care center and an affiliated secondary care center. Nineteen patients with a mean age of 68 years with prosthetic graft infection at the outflow anastomosis on a femoral artery at the Scarpa triangle underwent an infrascrotal, perineal, femorofemoral bypass, with excision of the graft material limited at the groin. The recipient artery was the profunda femoris artery in 12 cases, the superficial femoral in 5, and the distal common femoral artery in 2. Cumulative survival, recurrence of sepsis, primary graft patency, and limb salvage rates expressed by standard life-table analysis. Postoperative mortality rate was 5%. Cumulative (SE) survival rate was 65% (11.6%) at 3 years. Cumulative (SE) rate of freedom from recurrent sepsis was 88% (8.6%) at 3 years. Cumulative (SE) primary patency and limb salvage rates were 86% (9.4%) and 91% (7.9%), respectively, at 3 years. Femorofemoral bypass with an infrascrotal perineal approach is a valuable procedure for the treatment of femoral arterial graft infection limited at a unilateral groin.

  2. Preparation of pre-confluent retinal cells increases graft viability in vitro and in vivo: a mouse model.

    Directory of Open Access Journals (Sweden)

    Kevin P Kennelly

    Full Text Available PURPOSE: Graft failure remains an obstacle to experimental subretinal cell transplantation. A key step is preparing a viable graft, as high levels of necrosis and apoptosis increase the risk of graft failure. Retinal grafts are commonly harvested from cell cultures. We termed the graft preparation procedure "transplant conditions" (TC. We hypothesized that culture conditions influenced graft viability, and investigated whether viability decreased following TC using a mouse retinal pigment epithelial (RPE cell line, DH01. METHODS: Cell viability was assessed by trypan blue exclusion. Levels of apoptosis and necrosis in vitro were determined by flow cytometry for annexin V and propidium iodide and Western blot analysis for the pro- and cleaved forms of caspases 3 and 7. Graft viability in vivo was established by terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL and cleaved caspase 3 immunolabeling of subretinal allografts. RESULTS: Pre-confluent cultures had significantly less nonviable cells than post-confluent cultures (6.6%±0.8% vs. 13.1%±0.9%, p<0.01. Cell viability in either group was not altered significantly following TC. Caspases 3 and 7 were not altered by levels of confluence or following TC. Pre-confluent cultures had low levels of apoptosis/necrosis (5.6%±1.1% that did not increase following TC (4.8%±0.5%. However, culturing beyond confluence led to progressively increasing levels of apoptosis and necrosis (up to 16.5%±0.9%. Allografts prepared from post-confluent cultures had significantly more TUNEL-positive cells 3 hours post-operatively than grafts of pre-confluent cells (12.7%±3.1% vs. 4.5%±1.4%, p<0.001. Subretinal grafts of post-confluent cells also had significantly higher rates of cleaved caspase 3 than pre-confluent grafts (20.2%±4.3% vs. 7.8%±1.8%, p<0.001. CONCLUSION: Pre-confluent cells should be used to maximize graft cell viability.

  3. Open Repair of Mycotic Abdominal Aortic Aneurysms With Biological Grafts

    DEFF Research Database (Denmark)

    Heinola, Ivika; Sörelius, Karl; Wyss, Thomas R

    2018-01-01

    BACKGROUND: The treatment of mycotic abdominal aortic aneurysm requires surgery and antimicrobial therapy. Since prosthetic reconstructions carry a considerable risk of reinfection, biological grafts are noteworthy alternatives. The current study evaluated the durability, infection resistance......, and midterm outcome of biological grafts in treatment of mycotic abdominal aortic aneurysm. METHODS AND RESULTS: All patients treated with biological graft in 6 countries between 2006 and 2016 were included. Primary outcome measures were 30- and 90-day survival, treatment-related mortality, and reinfection...... rate. Secondary outcome measures were overall mortality and graft patency. Fifty-six patients (46 males) with median age of 69 years (range 35-85) were included. Sixteen patients were immunocompromised (29%), 24 (43%) had concomitant infection, and 12 (21%) presented with rupture. Bacterial culture...

  4. Primary testicular failure in Klinefelter's syndrome: the use of bivariate luteinizing hormone-testosterone reference charts

    DEFF Research Database (Denmark)

    Aksglaede, Lise; Andersson, Anna-Maria; Jørgensen, Niels

    2007-01-01

    The diagnosis of androgen deficiency is based on clinical features and confirmatory low serum testosterone levels. In early primary testicular failure, a rise in serum LH levels suggests inadequate androgen action for the individual's physiological requirements despite a serum testosterone level ...

  5. EASEPort NPWT System to Enhance Skin Graft Survival--A Simple Assembly.

    Science.gov (United States)

    Prasetyono, Theddeus O H; Rini, Irena Sakura; Wibisono, Cindy

    2015-03-01

    Skin graft has been known to be prone to failure. This study was aimed to make a simplification of the negative pressure wound therapy (NPWT), which follows EASEPort (effective, affordable, safe, easily handled, and portable) concept to support the take of skin graft. The design of the EASEPort-NPWT was then made and technically verified. Thereafter, an animal experimental study comparing the EASEPort-NPWT to the classic tie-over technique on skin graft over exudative wound was conducted. The EASEPort-NPWT was verified to be able to yield and sustain the subatmospheric pressure needed. In the animal study, the treatment group showed better skin graft survival rate (97.55 ± 11.18% take) than the control group (54.88 ± 19.73%) on day-7. Histopathology examination showed good quality of the skin structures taken from the treatment group, which was better than the structures of the skin in the control group. In summary, this study has been able to fulfill its objective to create a device following EASEPort concept. Subsequently, the EASEPort-NPWT was able to enhance skin graft survival rate in exudative wound.

  6. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  7. Predicting renal graft failure by sCD30 levels and de novo HLA antibodies at 1year post-transplantation.

    Science.gov (United States)

    Wang, Dong; Wu, Guojun; Chen, Jinhua; Yu, Ziqiang; Wu, Weizhen; Yang, Shunliang; Tan, Jianming

    2012-06-01

    HLA antibodies and sCD30 levels were detected in the serum sampled from 620 renal graft recipients at 1 year post-transplantation, which were followed up for 5 years. Six-year graft and patient survivals were 81.6% and 91.0%. HLA antibodies were detected in 45 recipients (7.3%), of whom there were 14 cases with class I antibodies, 26 cases with class II, and 5 cases with both class I and II. Much more graft loss was record in recipients with HLA antibodies than those without antibodies (60% vs. 15.1%, psCD30 levels were recorded in recipients suffering graft loss than the others (73.9±48.8 U/mL vs. 37.3±14.6 U/mL, psCD30 levels, recipients with low sCD30 levels (sCD30 on graft survival was not only independent but also additive. Therefore, post-transplantation monitoring of HLA antibodies and sCD30 levels is necessary and recipients with elevated sCD30 level and/or de novo HLA antibody should be paid more attention in order to achieve better graft survival. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Strength and fine dexterity recovery profiles after a primary motor cortex insult and effect of a neuronal cell graft.

    Science.gov (United States)

    Vaysse, Laurence; Conchou, Fabrice; Demain, Boris; Davoust, Carole; Plas, Benjamin; Ruggieri, Cyrielle; Benkaddour, Mehdi; Simonetta-Moreau, Marion; Loubinoux, Isabelle

    2015-08-01

    The aim of this study was to set up (a) a large primary motor cortex (M1) lesion in rodent and (b) the conditions for evaluating a long-lasting motor deficit in order to propose a valid model to test neuronal replacement therapies aimed at improving motor deficit recovery. A mitochondrial toxin, malonate, was injected to induce extensive destruction of the forelimb M1 cortex. Three key motor functions that are usually evaluated following cerebral lesion in the clinic-strength, target reaching, and fine dexterity-were assessed in rats by 2 tests, a forelimb grip strength test and a skilled reaching task (staircase) for reaching and dexterity. The potential enhancement of postlesion recovery induced by a neuronal cell transplantation was then explored and confirmed by histological analyses. Both tests showed a severe functional impairment 2 days post lesion, however, reaching remained intact. Deficits in forelimb strength were long lasting (up to 3 months) but spontaneously recovered despite the extensive lesion size. This natural grip strength recovery could be enhanced by cell therapy. Histological analyses confirmed the presence of grafted cells 3 months postgraft and showed partial tissue reconstruction with some living neuronal cells in the graft. In contrast, fine dexterity never recovered in the staircase test even after grafting. These results suggest that cell replacement was only partially effective and that the forelimb M1 area may be a node of the sensorimotor network, where compensation from secondary pathways could account for strength recovery but recovery of forelimb fine dexterity requires extensive tissue reconstruction. (c) 2015 APA, all rights reserved).

  9. Submillimeter Diameter Poly(Vinyl Alcohol) Vascular Graft Patency in Rabbit Model

    Science.gov (United States)

    Cutiongco, Marie F. A.; Kukumberg, Marek; Peneyra, Jonnathan L.; Yeo, Matthew S.; Yao, Jia Y.; Rufaihah, Abdul Jalil; Le Visage, Catherine; Ho, Jackie Pei; Yim, Evelyn K. F.

    2016-01-01

    Microvascular surgery is becoming a prevalent surgical practice. Replantation, hand reconstruction, orthopedic, and free tissue transfer procedures all rely on microvascular surgery for the repair of venous and arterial defects at the millimeter and submillimeter levels. Often, a vascular graft is required for the procedure as a means to bridge the gap between native arteries. While autologous vessels are desired for their bioactivity and non-thrombogenicity, the tedious harvest process, lack of availability, and caliber or mechanical mismatch contribute to graft failure. Thus, there is a need for an off-the-shelf artificial vascular graft that has low thrombogenic properties and mechanical properties matching those of submillimeter vessels. Poly(vinyl alcohol) hydrogel (PVA) has excellent prospects as a vascular graft due to its bioinertness, low thrombogenicity, high water content, and tunable mechanical properties. Here, we fabricated PVA grafts with submillimeter diameter and mechanical properties that closely approximated those of the rabbit femoral artery. In vitro platelet adhesion and microparticle release assay verified the low thrombogenicity of PVA. A stringent proof-of-concept in vivo test was performed by implanting PVA grafts in rabbit femoral artery with multilevel arterial occlusion. Laser Doppler measurements indicated the improved perfusion of the distal limb after implantation with PVA grafts. Moreover, ultrasound Doppler and angiography verified that the submillimeter diameter PVA vascular grafts remained patent for 2 weeks without the aid of anticoagulant or antithrombotics. Endothelial cells were observed in the luminal surface of one patent PVA graft. The advantageous non-thrombogenic and tunable mechanical properties of PVA that are retained even in the submillimeter diameter dimensions support the application of this biomaterial for vascular replacement in microvascular surgery. PMID:27376059

  10. Elevated plasma angiopoietin-2 levels and primary graft dysfunction after lung transplantation.

    Directory of Open Access Journals (Sweden)

    Joshua M Diamond

    Full Text Available Primary graft dysfunction (PGD is a significant contributor to early morbidity and mortality after lung transplantation. Increased vascular permeability in the allograft has been identified as a possible mechanism leading to PGD. Angiopoietin-2 serves as a partial antagonist to the Tie-2 receptor and induces increased endothelial permeability. We hypothesized that elevated Ang2 levels would be associated with development of PGD.We performed a case-control study, nested within the multi-center Lung Transplant Outcomes Group cohort. Plasma angiopoietin-2 levels were measured pre-transplant and 6 and 24 hours post-reperfusion. The primary outcome was development of grade 3 PGD in the first 72 hours. The association of angiopoietin-2 plasma levels and PGD was evaluated using generalized estimating equations (GEE.There were 40 PGD subjects and 79 non-PGD subjects included for analysis. Twenty-four PGD subjects (40% and 47 non-PGD subjects (59% received a transplant for the diagnosis of idiopathic pulmonary fibrosis (IPF. Among all subjects, GEE modeling identified a significant change in angiopoietin-2 level over time in cases compared to controls (p = 0.03. The association between change in angiopoietin-2 level over the perioperative time period was most significant in patients with a pre-operative diagnosis of IPF (p = 0.02; there was no statistically significant correlation between angiopoietin-2 plasma levels and the development of PGD in the subset of patients transplanted for chronic obstructive pulmonary disease (COPD (p = 0.9.Angiopoietin-2 levels were significantly associated with the development of PGD after lung transplantation. Further studies examining the regulation of endothelial cell permeability in the pathogenesis of PGD are indicated.

  11. Reconstruction of mandibular defects using nonvascularized autogenous bone graft in Nigerians

    Directory of Open Access Journals (Sweden)

    Kizito Chioma Ndukwe

    2014-01-01

    Full Text Available Objectives: The aim of this study is to evaluate the success rate and complications of mandibular reconstruction with nonvascularized bone graft in Ile-Ife, Nigeria. Patients and Methods: A total of 25 patients who underwent reconstruction of mandibular discontinuity defects between January 2003 and February 2012, at the Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife constituted the study sample. Relevant information was retrieved from the patients′ records. This information include patients′ demographics (age and sex as well as the type of mandibular defect, cause of the defect, type of mandibular resection done, source of the bone graft used, and the method of graft immobilization. Morbidity associated with the graft procedures were assessed by retrieving information on graft failures, length of hospital stay following surgery, rehabilitation device used and associated graft donor and recipient site complications. Result: There were 12 males and 13 females with a male:female ratio was 1:1.1. The age of the patients ranged from 13 to 73 years with a mean age for males 32.7 ± standard deviation (SD 12.9 and for females 35.0 ± SD 17.1. Jaw defect was caused by resection for tumours and other jaw pathologies in 92% of cases. Complete symphyseal involvement defect was the most common defect recorded 11 (44%. Reconstruction with nonvascularized rib graft accounted for 68% of cases while iliac crest graft was used in 32% of the patients. Successful take of the grafts was recorded in 22 patients while three cases failed. Wound dehiscence (two patients and postoperative wound infection (eight patients were the most common complications recorded. Conclusion: The use of nonvascularized graft is still relevant in the reconstruction of large mandibular defects caused by surgical ablation of benign conditions in Nigerians. Precise surgical planning and execution, extended antibiotic therapy, and meticulous postoperative care

  12. Endothelial chimerism and vascular sequestration protect pancreatic islet grafts from antibody-mediated rejection

    Science.gov (United States)

    Chen, Chien-Chia; Pouliquen, Eric; Broisat, Alexis; Andreata, Francesco; Racapé, Maud; Bruneval, Patrick; Kessler, Laurence; Ahmadi, Mitra; Bacot, Sandrine; Saison-Delaplace, Carole; Marcaud, Marina; Van Huyen, Jean-Paul Duong; Loupy, Alexandre; Villard, Jean; Demuylder-Mischler, Sandrine; Morelon, Emmanuel; Tsai, Meng-Kun; Kolopp-Sarda, Marie-Nathalie; Koenig, Alice; Mathias, Virginie; Ghezzi, Catherine; Dubois, Valerie; Defrance, Thierry

    2017-01-01

    Humoral rejection is the most common cause of solid organ transplant failure. Here, we evaluated a cohort of 49 patients who were successfully grafted with allogenic islets and determined that the appearance of donor-specific anti-HLA antibodies (DSAs) did not accelerate the rate of islet graft attrition, suggesting resistance to humoral rejection. Murine DSAs bound to allogeneic targets expressed by islet cells and induced their destruction in vitro; however, passive transfer of the same DSAs did not affect islet graft survival in murine models. Live imaging revealed that DSAs were sequestrated in the circulation of the recipients and failed to reach the endocrine cells of grafted islets. We used murine heart transplantation models to confirm that endothelial cells were the only accessible targets for DSAs, which induced the development of typical microvascular lesions in allogeneic transplants. In contrast, the vasculature of DSA-exposed allogeneic islet grafts was devoid of lesions because sprouting of recipient capillaries reestablished blood flow in grafted islets. Thus, we conclude that endothelial chimerism combined with vascular sequestration of DSAs protects islet grafts from humoral rejection. The reduced immunoglobulin concentrations in the interstitial tissue, confirmed in patients, may have important implications for biotherapies such as vaccines and monoclonal antibodies. PMID:29202467

  13. Randomized comparison of the clinical outcome of single versus multiple arterial grafts: the ROMA trial-rationale and study protocol.

    Science.gov (United States)

    Gaudino, Mario; Alexander, John H; Bakaeen, Faisal G; Ballman, Karla; Barili, Fabio; Calafiore, Antonio Maria; Davierwala, Piroze; Goldman, Steven; Kappetein, Peter; Lorusso, Roberto; Mylotte, Darren; Pagano, Domenico; Ruel, Marc; Schwann, Thomas; Suma, Hisayoshi; Taggart, David P; Tranbaugh, Robert F; Fremes, Stephen

    2017-12-01

    The primary hypothesis of the ROMA trial is that in patients undergoing primary isolated non-emergent coronary artery bypass grafting, the use of 2 or more arterial grafts compared with a single arterial graft (SAG) is associated with a reduction in the composite outcome of death from any cause, any stroke, post-discharge myocardial infarction and/or repeat revascularization. The secondary hypothesis is that in these patients, the use of 2 or more arterial grafts compared with a SAG is associated with improved survival. The ROMA trial is a prospective, unblinded, randomized event-driven multicentre trial comprising at least 4300 subjects. Patients younger than 70 years with left main and/or multivessel disease will be randomized to a SAG or multiple arterial grafts to the left coronary system in a 1:1 fashion. Permuted block randomization stratified by the centre and the type of second arterial graft will be used. The primary outcome will be a composite of death from any cause, any stroke, post-discharge myocardial infarction and/or repeat revascularization. The secondary outcome will be all-cause mortality. The primary safety outcome will be a composite of death from any cause, any stroke and any myocardial infarction. In all patients, 1 internal thoracic artery will be anastomosed to the left anterior descending coronary artery. For patients randomized to the SAG group, saphenous vein grafts will be used for all non-left anterior descending target vessels. For patients randomized to the multiple arterial graft group, the main target vessel of the lateral wall will be grafted with either a radial artery or a second internal thoracic artery. Additional grafts for the multiple arterial graft group can be saphenous veins or supplemental arterial conduits. To detect a 20% relative reduction in the primary outcome, with 90% power at 5% alpha and assuming a time-to-event analysis, the sample size must include 845 events (and 3650 patients). To detect a 20% relative

  14. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  15. Obstructive uropathy and acute renal failure due to ureteral calculus in renal graft: a case report.

    Science.gov (United States)

    Lusenti, T; Fiorini, F; Barozzi, L

    2009-09-01

    Obstructive uropathy caused by kidney stones is quite rare in transplant kidneys. The authors report the case of a patient, previously gastrectomized for gastric carcinoma. He underwent renal transplantation using uretero-ureterostomy, and presented an episode of acute renal failure 7 years after surgery. Ultrasound (US) examination showed no sign of rejection but allowed detection of moderate hydronephrosis in the transplant kidney. Subsequent computed tomography (CT) revealed a kidney stone in the middle ureter at the crossing of the iliac vessels. The patient therefore urgently underwent percutaneous nephrostomy of the graft and recovered diuresis and renal function. The patient was transferred to the Transplant Center where he underwent ureterotomy with removal of the stone and subsequent ureteropyelostomy. Also transureteral resection of the prostate (TURP) was performed due to urinary retention of prostatic origin. Histological examination showed prostate carcinoma, Gleason stage 3, which was treated conservatively using radiotherapy without suspension of the administered low dose of immunotherapy. Calculosis is one of the least common causes of obstructive uropathy in transplant kidneys. In the described case, US examination performed after onset of renal insufficiency led to subsequent radiological investigation and resulting interventional procedures (nephrostomy and surgical removal of the stone) with complete recovery of pre-existing renal function.

  16. Decontamination of nuclear plant fluids with grafted celluloses

    International Nuclear Information System (INIS)

    Sandeaux, R.

    1991-01-01

    Ion exchange processes are specially well adapted techniques to solve some of nuclear plants problems, such as decontamination of the primary cooling circuit fluid and the cooling pool, because of the low concentration of the miscellaneous products to eliminate. Now the purification of these fluids is performed by using ion exchange resins. But recent researches show it is necessary to use more efficient techniques (1). The use of grafted celluloses should improve this process. The manufacturing of grafted celluloses was first performed with the collaboration of French Textile Institute and Morgane-Framatome (2). Cellulosic structure offers well known qualities for filtration: good micrometric retention, good mechanical behaviour, strong hydrophilic properties and high specific surface. Grafting was performed through a radiochemical process so as to bind polyelectrolytes on the backbone polymer. Compared to usual ion exchangers, these new materials offer different properties: - fast exchange kinetic - as uncrosslinked polymers, these grafted celluloses withstand better fouling with macroions or ionic complexes; - as they can be incinerated, radioactive wastes can be greatly reduced; - different commercial products of these grafted celluloses offer a wide range of possibilities for industrial uses [fr

  17. Local vs. systemic administration of bisphosphonates in rat cleft bone graft: A comparative study.

    Directory of Open Access Journals (Sweden)

    Christine Hong

    Full Text Available A majority of patients with orofacial cleft deformity requires cleft repair through a bone graft. However, elevated amount of bone resorption and subsequent bone graft failure remains a significant clinical challenge. Bisphosphonates (BPs, a class of anti-resorptive drugs, may offer great promise in enhancing the clinical success of bone grafting. In this study, we compared the effects of systemic and local delivery of BPs in an intraoral bone graft model in rats. We randomly divided 34 female 20-week-old Fischer F344 Inbred rats into four groups to repair an intraoral critical-sized defect (CSD: (1 Control: CSD without graft (n = 4; (2 Graft/Saline: bone graft with systemic administration of saline 1 week post-operatively (n = 10; (3 Graft/Systemic: bone graft with systemic administration of zoledronic acid 1 week post-operatively (n = 10; and (4 Graft/Local: bone graft pre-treated with zoledronic acid (n = 10. At 6-weeks post-operatively, microCT volumetric analysis showed a significant increase in bone fraction volume (BV/TV in the Graft/Systemic (62.99 ±14.31% and Graft/Local (69.35 ±13.18% groups compared to the Graft/Saline (39.18±10.18%. Similarly, histological analysis demonstrated a significant increase in bone volume in the Graft/Systemic (78.76 ±18.00% and Graft/Local (89.95 ±4.93% groups compared to the Graft/Saline (19.74±18.89%. The local delivery approach resulted in the clinical success of bone grafts, with reduced graft resorption and enhanced osteogenesis and bony integration with defect margins while avoiding the effects of BPs on peripheral osteoclastic function. In addition, local delivery of BPs may be superior to systemic delivery with its ease of procedure as it involves simple soaking of bone graft materials in BP solution prior to graft placement into the defect. This new approach may provide convenient and promising clinical applications towards effectively managing cleft patients.

  18. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias [University Hospital of Bern, Inselspital, Department of Radiology, Bern (Switzerland); Steinbach, Lynne S. [University of California San Francisco, Department of Radiology, San Francisco, California (United States); Nagy, Ladislav [University Hospital of Bern, Inselspital, Department of Orthopedic Surgery, Bern (Switzerland)

    2005-06-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  19. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    International Nuclear Information System (INIS)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias; Steinbach, Lynne S.; Nagy, Ladislav

    2005-01-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  20. Derivation of a Predictive Model for Graft Loss Following Acute Kidney Injury in Kidney Transplant Recipients.

    Science.gov (United States)

    Molnar, Amber O; van Walraven, Carl; Fergusson, Dean; Garg, Amit X; Knoll, Greg

    2017-01-01

    Acute kidney injury (AKI) is common in the kidney transplant population. To derive a multivariable survival model that predicts time to graft loss following AKI. Retrospective cohort study using health care administrative and laboratory databases. Southwestern Ontario (1999-2013) and Ottawa, Ontario, Canada (1996-2013). We included first-time kidney only transplant recipients who had a hospitalization with AKI 6 months or greater following transplant. AKI was defined using the Acute Kidney Injury Network criteria (stage 1 or greater). The first episode of AKI was included in the analysis. Graft loss was defined by return to dialysis or repeat kidney transplant. We performed a competing risk survival regression analysis using the Fine and Gray method and modified the model into a simple point system. Graft loss with death as a competing event was the primary outcome of interest. A total of 315 kidney transplant recipients who had a hospitalization with AKI 6 months or greater following transplant were included. The median (interquartile range) follow-up time was 6.7 (3.3-10.3) years. Graft loss occurred in 27.6% of the cohort. The final model included 6 variables associated with an increased risk of graft loss: younger age, increased severity of AKI, failure to recover from AKI, lower baseline estimated glomerular filtration rate, increased time from kidney transplant to AKI admission, and receipt of a kidney from a deceased donor. The risk score had a concordance probability of 0.75 (95% confidence interval [CI], 0.69-0.82). The predicted 5-year risk of graft loss fell within the 95% CI of the observed risk more than 95% of the time. The CIs of the estimates were wide, and model overfitting is possible due to the limited sample size; the risk score requires validation to determine its clinical utility. Our prognostic risk score uses commonly available information to predict the risk of graft loss in kidney transplant patients hospitalized with AKI. If validated

  1. Kidney transplant graft outcomes in 379 257 recipients on 3 continents.

    Science.gov (United States)

    Merion, Robert M; Goodrich, Nathan P; Johnson, Rachel J; McDonald, Stephen P; Russ, Graeme R; Gillespie, Brenda W; Collett, David

    2018-03-24

    Kidney transplant outcomes that vary by program or geopolitical unit may result from variability in practice patterns or health care delivery systems. In this collaborative study, we compared kidney graft outcomes among 4 countries (United States, United Kingdom, Australia, and New Zealand) on 3 continents. We analyzed transplant and follow-up registry data from 1988-2014 for 379 257 recipients of first kidney-only transplants using Cox regression. Compared to the United States, 1-year adjusted graft failure risk was significantly higher in the United Kingdom (hazard ratio [HR] 1.22, 95% confidence interval [CI] 1.18-1.26, P < .001) and New Zealand (hazard ratio [HR] 1.29, 95% confidence interval [CI] 1.14-1.46, P < .001), but lower in Australia (HR 0.90, 95% CI 0.84-0.96, P = .001). In contrast, long-term adjusted graft failure risk (conditional on 1-year function) was significantly higher in the United States compared to Australia, New Zealand, and the United Kingdom (HR 0.74, 0.75, and 0.74, respectively; each P < .001). Thus long-term kidney graft outcomes are approximately 25% worse in the United States than in 3 other countries with well-developed kidney transplant systems. Case mix differences and residual confounding from unmeasured factors were found to be unlikely explanations. These findings suggest that identification of potentially modifiable country-specific differences in care delivery and/or practice patterns should be sought. © 2018 The American Society of Transplantation and the American Society of Transplant Surgeons.

  2. Dysphagia after Colon Interposition Graft for Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    C. Spitali

    2012-01-01

    Full Text Available Colon interposition is an established technique for esophageal reconstruction. We describe the case of primary adenocarcinoma arising in a colonic interposition graft that was performed after total esophagectomy for recurrence adenocarcinoma derived from the Barrett esophagus.

  3. Predominant or complete recipient T-cell chimerism following alemtuzumab-based allogeneic transplantation is reversed by donor lymphocytes and not associated with graft failure.

    Science.gov (United States)

    Mohamedbhai, Sajir G; Edwards, Noha; Morris, Emma C; Mackinnon, Stephen; Thomson, Kirsty J; Peggs, Karl S

    2012-02-01

    The clinical significance of mixed chimerism following allogeneic haematopoietic stem cell transplantation (HSCT) remains controversial. Its relevance and incidence are probably influenced by the conditioning regimen and incorporation of T-cell depletion. The presence of recipient chimerism levels >40-50% following T-cell replete reduced intensity transplantation correlates with a high risk of graft rejection, regardless of donor-lymphocyte infusions, but it is unclear whether this finding translates to T-cell depleted transplants. We conducted a retrospective single-institution analysis of patients receiving alemtuzumab-based HSCT. 27/152 (18%) evaluable cases had predominantly recipient T-cell chimerism at 3 months or beyond. By contrast, coincident chimerism in the granulocyte lineage was predominantly of donor origin (median 100%) in all but one patient. Donor lymphocyte infusion effectively converted predominantly recipient T-cell chimerism to ful donor chimerism in all evaluable cases including three cases with no detectable donor T cells. The only graft failure occurred in the patient with predominantly recipient myeloid chimerism in whom rejection occurred rapidly before donor lymphocytes could be administered. We conclude that predominant or complete recipient T-cell chimerism following alemtuzumab-based regimens does not have the same clinical implications as that following T-cell replete transplants and can be effectively converted with donor lymphocytes without the need for lympho-depleting agents or re-conditioning. © 2011 Blackwell Publishing Ltd.

  4. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  5. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  6. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  7. Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Uflacker, Renan; Elliott, Bruce M.

    1996-01-01

    A stent-graft was custom made to close a high-flow traumatic arteriovenous fistula of the left superficial femoral artery, present for 30 years, in a 60-year-old man with congestive heart failure and ischemic ulceration in the left foot. A balloon expandable Palmaz stent (P394; 2.5 mm x 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graft and was inserted percutaneously through an 11 Fr vascular sheath. Follow-up Doppler ultrasound at 6 months demonstrated occlusion of the arteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein

  8. Graft tendon slippage with metallic and bioabsorbable interference screws under cyclic load: a biomechanical study in a porcine model

    Directory of Open Access Journals (Sweden)

    Ari Digiácomo Ocampo Moré

    Full Text Available Introduction The rupture of the anterior cruciate ligament (ACL is the most common type of knee injury. Reconstructive surgery is the ‘gold standard’ treatment. During the immediate post-operative period, the fixation of the graft is entirely dependent on the ability of the grafted implant to be secured inside the bone tunnel under the cyclical loads associated with daily tasks. Poor fixation can lead to graft slippage, thus impairing the healing and integration of the graft. The aim of this study was to evaluate the biomechanical performance of tendon graft fixation devices with metallic and bioabsorbable interference screws. Methods Twenty ACL reconstructions were carried out in porcine tibias using deep flexor tendons to fix 9 × 20 mm metallic (n=10 and PLLA 70/30 bioabsorbable screws (n=10. To verify the ability of a construct to resist immediate postoperative (PO rehabilitation protocols for immediate load bearing, a cyclic loading test was applied with 50-250 N of tensile force at 1 Hz for 1000 cycles, and the displacement was measured at 10, 50, 100, 500 and 1000 load cycles to quantify the slippage of the graft during the test. After the cyclic loading test, a single-cycle load-to-failure test was applied. Results The slippage of the graft using metallic screws did not differ (P = 0.616 from that observed when using bioabsorbable screws. Conclusion The results obtained in this experiment indicate that metallic screws may promote a similar amount of graft slippage during low cyclic loading as bioabsorbable screws. Additionally, there was no difference in the biomechanical performance of these two types of screws during high failure loads.

  9. Improved endothelial cell seeding with cultured cells and fibronectin-coated grafts

    International Nuclear Information System (INIS)

    Seeger, J.M.; Klingman, N.

    1985-01-01

    A possible approach to the low seeding efficiency of endothelial cells into prosthetic grafts is to increase the number of cells to be seeded in cell culture and improve seeding efficiency by graft precoating with fibronectin. The effect of cell culture on cell adhesion is unknown, however, and fibronectin also binds fibrin, which may increase the thrombogenicity of the graft luminal surface. To investigate these questions, freshly harvested canine jugular vein endothelial cells from six animals and similar cells harvested from six primary and eight secondary cell cultures were labeled with 111 Indium and seeded into 5 cm, 4 mm PTFE grafts coated with fibronectin, using similar uncoated PTFE grafts as controls. Platelet accumulation and distribution on six similar coated and uncoated grafts placed in canine carotid, external jugular arterial venous shunts for 2 hr were also determined using autogenous 111 Indium-labeled platelets. Significant differences between group means were determined using the paired Student's t test. Results reveal that seeding efficiency is significantly better in all groups of coated grafts compared to uncoated grafts (P less than 0.01). Cells derived from cell culture also had significantly higher seeding efficiencies than freshly harvested cells when seeded into coated grafts (P less than 0.05) and tended to have higher seeding efficiencies than harvested cells when seeded into uncoated grafts (P = 0.53). Fibronectin coating increased mean platelet accumulation on the entire graft luminal surface, but not to a statistically significant degree (P greater than 0.1). Whether this increased seeding efficiency will improve graft endothelialization remains to be investigated

  10. Synthesis of Radiation Grafted Polymer Matrices for Separation and Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhardwaj, Y K; Virendra, K; Goel, N K; Sarma, K S.S.; Sabharwal, S [Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2012-09-15

    Grafting of acrylonitrile onto non-woven porous polypropylene fibre sheet using electron beam was carried out by post-irradiation grafting. Grafting extent of {approx}125% was achieved. The grafted nitrile groups were amidoximated and studied for uranium uptake from sea water and heavy metal ions (Co{sup 2+}, Ni{sup 2+}, Mn{sup 2+}, and Cd{sup 2+}) from aqueous solutions. Adsorption and elution of adsorbed ions in suitable eluents was studied. The grafting process was upgraded to pilot scale to obtain 1x1 m{sup 2} sheets. Mutual radiation grafting technique was used for grafting of vinylbenzyltrimethyl ammonium chloride, [2- (methacryloyloxy)ethyl] trimethylammonium chloride and [2-(acryloyloxyethyl)]trimethylammonium chloride onto cotton cellulose substrate. The grafted matrices showed significantly higher water uptake and good water retention properties. The antibacterial efficacy of the grafted products was found to be a function of extent of grafting and the type of bacteria (Escherichia coli, Pseudomonas flourescens, Staphylococcus aureus and Bacillus cereus). PVBT-g-cotton was studied for its protein adsorption behaviour in continuous column process using Bovine serum albumin (BSA) as a model protein. Mutual radiation grafting technique was used to graft acrylic acid on micrometer thick micro-porous polypropylene membrane. Contact angle measurement studies showed that initial grafting as well as radiation treatment of poly(propylene) in aqueous medium and in presence of Mohr's salt enhances its affinity towards the grafting solution. The enhancement in the polar component of surface energy of treated polypropylene membrane is the primary cause of grafting enhancement. The membranes grafted to an extent of {approx}20% were found to perform comparably with the battery separator presently being used by battery industry. Acrylic acid was grafted to Teflon scrap by mutual radiation grafting technique. The grafting extent decreased with increasing dose rate and

  11. Improving coronary artery bypass grafting readmission outcomes from 2000 to 2012 in the Medicare population.

    Science.gov (United States)

    McNeely, Christian; Kwedar, Kathleen; Markwell, Stephen; Vassileva, Christina M

    2017-10-01

    The study objective was to examine trends in 30-day readmission after coronary artery bypass grafting in the Medicare population over 13 years. The study included isolated coronary artery bypass grafting procedures in the Medicare population from January 2000 to November 2012. Comorbidities and causes of readmission were determined using Internal Classification of Diseases, 9th Revision, Clinical Modification diagnostic codes. The cohort included 1,116,991 patients. Readmission rates decreased from 19.5% in 2000 to 16.6% in 2012 (P = .0001). There was significant improvement across all categories of admission status, age, race, gender, and hospital annual coronary artery bypass grafting volume that were analyzed. Adjusted odds of readmission in 2000 compared with 2012 was 1.28 (95% confidence interval, 1.24-1.32). Median length of stay for the readmission episode was 5 days, which improved to 4 days by 2012. Hospital mortality during the readmission episode was 2.8% overall and declined to 2.4% in 2012 (P = .0001). The most common primary readmission diagnoses were heart failure (12.6%), postoperative wound infection/nonhealing wound (8.9%), arrhythmias (6.4%), and pleural effusions (3.7%). Readmission for wound infections/nonhealing wounds decreased significantly over time, from 9.8% to 6.5% (P = .0001). In a large cohort of Medicare patients undergoing coronary artery bypass grafting over 13 years, there was a significant decrease in 30-day readmission rates, a reduction in readmission for wound infections, and reduced mortality during the readmission episode, despite an increase in patient comorbidities. The improvement in readmission rates was seen regardless of patient variables examined. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Rapid Progression of Metastatic Pulmonary Calcification and Alveolar Hemorrhage in a Patient with Chronic Renal Failure and Primary Hyperparathyroidism

    International Nuclear Information System (INIS)

    Yoon, Eun Joo; Kim, Dong Hun; Yoon, Seong Ho; Suk, Eun Ha

    2013-01-01

    Metastatic pulmonary calcification (MPC) is common in patients with chronic renal failure. The authors experienced a patient with chronic renal failure and primary hyperparathyroidism by parathyroid adenoma accompanied with rapid progressions of MPC and alveolar hemorrhage. Recent chest radiographs, compared with previous chest radiographs, showed rapid accumulation of calcification in both upper lungs. Following up on the high-resolution CT scan after five years demonstrates more increased nodules in size and ground glass opacity. The patient was diagnosed with MPC and alveolar hemorrhage by transbronchial lung biopsy. We assumed rapid progression of MPC and alveolar hemorrhage in underlying chronic renal failures could be a primary hyperparathyroidism which may be caused by parathyroid adenoma detected incidentally. Therefore parathyroid adenoma was treated with ethanol injections. Herein, we have reported on CT findings of MPC with alveolar hemorrhage and reviewed our case along with other articles.

  13. Two-stage liver transplantation using auxiliary laparoscopically harvested grafts in adults: Emphasizing the concept of "hypersmall graft nursing".

    Science.gov (United States)

    Scatton, Olivier; Cauchy, François; Conti, Filomena; Perdigao, Fabiano; Massault, Pierre Philippe; Goumard, Claire; Soubrane, Olivier

    2016-11-01

    Living donor liver transplantation is limited by the donor's risk in case of right liver donation and by the risk of small-for-size syndrome on the recipient in case of left lobe transplantation. This study aimed at evaluating the feasibility and results of two-stage liver transplantation using auxiliary hyper small grafts harvested laparoscopically and discussing relevant technical insights and issues that still need to be overcome. Retrospective analysis involving two patients operated at a tertiary referral center. The recipients underwent left lateral sectionectomy and then auxillary liver transplantation using laparoscopically harvested left lateral section. The native right liver was transiently left in place to sustain the initially small functional graft functional during its hypertrophy. No donor experienced postoperative complication. After 7days, the hypertrophy rate was 112% (105-120). Doppler assessments during the first two postoperative weeks showed progressive portal vein inflow decrease in the right native livers and portal vein inflow increase in the grafts. Liver biopsies on postoperative day 7 showed no lesion of overperfusion. No recipient experienced liver failure or small-for-size syndrome. Second stage hepatectomy of the native liver was undertaken in one patient. In the other patient, biliary stenosis on postoperative day 30 precluded second stage hepatectomy. This patient required retransplantation after one year. The current strategy increases donor safety and may allow increasing the pool of available grafts. Refinements in the management of the native right liver are however required to improve the feasibility rate of this strategy. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Signs for early diagnosis of heart failure in primary health care

    Directory of Open Access Journals (Sweden)

    Devroey D

    2011-09-01

    Full Text Available Dirk Devroey1,2, Viviane Van Casteren11Scientific Institute of Public Health, Unit of Epidemiology, Brussels, Belgium; 2Vrije Universiteit Brussel (VUB, Department of Family Medicine, Brussels, BelgiumObjective: The current guidelines for the diagnosis of heart failure (HF are based on studies of hospital-based patients. The aim of this study is to describe the symptoms, clinical signs, and diagnostic procedures confirming the diagnosis of HF in primary health care.Materials/subjects and methods: Data were prospectively collected during a 2-year period by a nationwide network of sentinel practices. All adult patients without known HF, for which the diagnosis of HF was clinically suspected for the first time, were registered. When diagnosed, HF was confirmed after 1 month.Results: 754 patients with a suspicion of HF were recorded. The diagnosis of HF was confirmed for 74% of the patients. The average age of the patients with confirmed HF was 77.7 years, and for those without HF 75.6 years (P = 0.018. From a logistic regression, breathlessness on exercise (P < 0.001, limitations of physical activity (P = 0.003, and orthopnea (P = 0.040 were the symptoms most associated with HF. The clinical signs most associated with HF, were pulmonary rales (P < 0.001, peripheral edema (P < 0.001, and raised jugular venous pressure (P = 0.039. An electrocardiogram was performed in 75% of the cases, blood analyses in 68%, echocardiogram in 63%, chest X-ray in 61%, and determination of natriuretic peptides in 11% of the cases.Conclusion: Many clinical signs may occur in patients with HF. However, the occurrence of peripheral edema, breathlessness on exercise, or pulmonary rales, are highly suggestive for HF when diagnosed in primary health care, as is the case in hospital-admitted patients. The diagnosis of HF was often left unconfirmed by an echocardiogram and/or an electrocardiogram.Keywords: heart failure, primary health care, diagnostic clinical signs

  15. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  16. Long-term follow-up in optimally treated and stable heart failure patients : primary care vs. heart failure clinic. Results of the COACH-2 study

    NARCIS (Netherlands)

    Luttik, Marie Louise A.; Jaarsma, Tiny; van Geel, Peter Paul; Brons, Maaike; Hillege, Hans L.; Hoes, Arno W.; de Jong, Richard; Linssen, Gerard; Lok, Dirk J. A.; Berger, Marjolein; van Veldhuisen, Dirk J.

    2014-01-01

    AimsIt has been suggested that home-based heart failure (HF) management in primary care may be an alternative to clinic-based management in HF patients. However, little is known about adherence to HF guidelines and adherence to the medication regimen in these home-based programmes. The aim of the

  17. Primary Palatoplasty for Unilateral Cleft Lip and Palate Using Mucosal Grafts and Flaps.

    Science.gov (United States)

    Torikai, Katsuyuki; Kijima, Takeshi; Hirakawa, Takashi; Naganishi, Hiroki; Ishiwata, Yasuo; Fukawa, Toshihiko; Funaki, Junzo; Nagaoka, Ryosuke; Suzuki, Keiko; Sano, Tsuguo

    2015-09-01

    The mucosal graft and flaps method (MG method) is a palatoplasty technique that was developed for the purpose of improving maxillary growth in patients with cleft palate. In the MG method, full-thickness buccal mucosa is grafted onto the raw surface created by pushback palatoplasty. The method is unlikely to result in severe scarring and has a favorable effect on maxillary growth. In addition, it is unlikely to result in oronasal fistula and provides good speech results. Overall, postive long-term treatment results have been obtained. Although the MG method is technically difficult and requires a lengthy surgery, the technique is considered to be effective for palate closure in terms of speech and maxillary growth.

  18. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-06-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  19. Self-expandable metallic stents for patients with recurrent esophageal carcinoma after failure of primary chemoradiotherapy

    International Nuclear Information System (INIS)

    Muto, Manabu; Ohtsu, Atsushi; Boku, Narikazu; Yoshida, Shigeaki; Miyata, Yoshinori; Shioyama, Yasukazu

    2001-01-01

    Recent advances in chemoradiotherapy for esophageal carcinoma have resulted in improved survival rates. However, there are few options for recurrent dysphagia due to refractory carcinoma after failure of primary chemoradiotherapy. The aim of this study was to evaluate the safety and efficacy of self-expandable metallic stent placement for patients with recurrent esophageal carcinoma where definitive chemoradiotherapy has failed. Thirteen consecutive patients with recurrent squamous cell carcinoma of the esophagus, in whom self-expandable metallic stents were placed after failure of primary chemoradiotherapy, were studied retrospectively. All patients had esophageal obstruction or malignant fistula. The oral alimentation status of nine of 13 patients (69%) improved after successful placement of the stent. Following placement of the stent, fever (>38 deg C) and severe chest pain occurred in 85% (11/13) of the patients. In all patients examined, C-reactive protein was elevated within 1 week of the operation. Esophageal perforation occurred in three patients. Stent-related mediastinitis and pneumonia developed in six (46%) and three (23%) patients, respectively. Seven of the 13 patients (54%) died of stent-related pulmonary complications. Although the placement of a self-expandable metallic stent for patients with recurrent esophageal carcinoma after failure of chemoradiotherapy improved their oral alimentation status, we found that this treatment increases the risk of life-threatening pulmonary complications. (author)

  20. Bone marrow dysfunction in chronic heart failure patients

    NARCIS (Netherlands)

    Westenbrink, B. Daan; Voors, Adriaan A.; de Boer, Rudolf A.; Schuringa, Jan J.; Klinkenberg, Theo; van der Harst, Pim; Vellenga, Edo; van Veldhuisen, Dirk J.; van Gilst, Wiek H.

    To investigate whether chronic heart failure (CHF) is associated with a general dysfunction of the haematopoietic compartment. Bone marrow was obtained during coronary artery bypass graft surgery from 20 patients with CHF (age 67 +/- 6 years, 75% NYHA class >= III, LVEF 32 +/- 6%), and 20 age- and

  1. Percutaneous treatment of complications occurring during hemodialysis graft recanalization

    Energy Technology Data Exchange (ETDEWEB)

    Sofocleous, Constantinos T. E-mail: constant@pol.net; Schur, Israel; Koh, Elsie; Hinrichs, Clay; Cooper, Stanley G.; Welber, Adam; Brountzos, Elias; Kelekis, Dimitris

    2003-09-01

    Introduction/objective: To describe and evaluate percutaneous treatment methods of complications occurring during recanalization of thrombosed hemodialysis access grafts. Methods and materials: A retrospective review of 579 thrombosed hemodialysis access grafts revealed 48 complications occurring during urokinase thrombolysis (512) or mechanical thrombectomy (67). These include 12 venous or venous anastomotic ruptures not controlled by balloon tamponade, eight arterial emboli, 12 graft extravasations, seven small hematomas, four intragraft pseudointimal 'dissections', two incidents of pulmonary edema, one episode of intestinal angina, one procedural death, and one distant hematoma. Results: Twelve cases of post angioplasty ruptures were treated with uncovered stents of which 10 resulted in graft salvage allowing successful hemodialysis. All arterial emboli were retrieved by Fogarty or embolectomy balloons. The 10/12 graft extravasations were successfully treated by digital compression while the procedure was completed and the graft flow was restored. Dissections were treated with prolonged Percutaneous Trasluminal Angioplasty (PTA) balloon inflation. Overall technical success was 39/48 (81%). Kaplan-Meier Primary and secondary patency rates were 72 and 78% at 30, 62 and 73% at 90 and 36 and 67% at 180 days, respectively. Secondary patency rates remained over 50% at 1 year. There were no additional complications caused by these maneuvers. Discussions and conclusion: The majority of complications occurring during percutaneous thrombolysis/thrombectomy of thrombosed access grafts, can be treated at the same sitting allowing completion of the recanalization procedure and usage of the same access for hemodialysis.

  2. [Oral mucosa graft urethroplasty for complicated urethral strictures].

    Science.gov (United States)

    Horiguchi, Akio; Sumitomo, Makoto; Kanbara, Taiki; Tsujita, Yujiro; Yoshii, Takahiko; Yoshii, Hidehiko; Satoh, Akinori; Asakuma, Junichi; Ito, Keiichi; Hayakawa, Masamichi; Asano, Tomohiko

    2010-03-01

    We evaluated the efficacy and outcome of one-stage oral mucosa graft urethroplasty, which is currently the procedure of choice for treating lengthy and complicated urethral strictures not amenable to excision and primary end-to-end anastomosis. Seven patients 33 to 74 years old (mean age = 53.7) underwent one-stage oral mucosa graft urethroplasty for a stricture in either the bulbar urethra (four patients), penile urethra (two patients), or pan-anterior urethra (one patient). Three of the strictures were due to trauma, one was due to inflammation, and one was due to a failed hypospadia repair. The other two were iatrogenic. All patients had previously undergone either internal urethrotomy or repeated urethral dilation. Three patients received a tube graft, three received a ventral onlay, and one received a dorsal onlay. A free graft of oral mucosa was harvested from the inside of each patient's left cheek, and if necessary to obtain a sufficient length, the harvest was extended to include mucosa from the lower lip and the right cheek. The graft lengths ranged from 2.5 to 12 cm (mean = 4.6 cm). A urethral catheter was left in place for 3 weeks postoperatively. While no severe complications at the donor site were observed during follow-up periods ranging from 3 to 55 months (mean = 14 months), two patients who had received a tube graft developed distal anastomotic ring strictures that were managed by internal urethrotomy. The other five required no postoperative urological procedure even though one who had received a ventral onlay developed a penoscrotal fistula. Oral mucosa is an ideal urethral graft, and oral mucosa graft urethroplasty is an effective procedure for repairing complicated urethral strictures involving long portions of the urethra.

  3. Early post-transplant immune monitoring can predict long-term kidney graft survival: soluble CD30 levels, anti-HLA antibodies and IgA-anti-Fab autoantibodies.

    Science.gov (United States)

    Amirzargar, Mohammad Ali; Amirzargar, Aliakbar; Basiri, Abbas; Hajilooi, Mehrdad; Roshanaei, Ghodratollah; Rajabi, Gholamreza; Mohammadiazar, Sina; Solgi, Ghasem

    2014-01-01

    This study aimed to investigate the predictive power of anti-HLA antibodies, sCD30 levels and IgA-anti-Fab autoantibody before and early after transplantation in relation to long-term kidney allograft survival. Pre- and post-transplant sera samples of 59 living-unrelated donor kidney recipients were tested for above risk factors by enzyme-linked immunoabsorbent assay. 15 out of 59 cases experienced rejection episodes (failure group). Pre- and post-transplant high sCD30 levels were significantly associated with graft failure (P=0.02 and P=0.004) and decreased 4 year graft survival (P = 0.009 and P = 0.001). Higher frequency of post-transplant HLA class-II antibody in the absence of class-I antibody was observed in failure group (P=0.007). Patients with post-transplant HLA class-I and class-II antibodies either alone or in combination showed significant lower 4 year graft survival. Recipients with high sCD30 levels in the presence of HLA class-I or class-II antibodies within 2 weeks post-transplant had poor graft survival (P = 0.004 and P = 0.002, respectively). High levels of post-transplant IgA-anti-Fab antibody was more frequent in functioning-graft patients (P = 0.00001), correlated with decreased serum creatinine levels (P = 0.01) and associated with improved graft survival (P = 0.008). Our findings indicate the deleterious effect of early post-transplant HLA antibodies and increased sCD30 levels dependently and protective effect of IgA-anti-Fab antibodies on long-term renal graft outcomes. Copyright © 2013 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  4. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  5. Biomechanical Comparison of an Intramedullary and Extramedullary Free-Tissue Graft Reconstruction of the Acromioclavicular Joint Complex

    Science.gov (United States)

    Garg, Rishi; Javidan, Pooya; Lee, Thay Q.

    2013-01-01

    Background Several different surgical techniques have been described to address the coracoclavicular (CC) ligaments in acromioclavicular (AC) joint injuries. However, very few techniques focus on reconstructing the AC ligaments, despite its importance in providing stability. The purpose of our study was to compare the biomechanical properties of two free-tissue graft techniques that reconstruct both the AC and CC ligaments in cadaveric shoulders, one with an extramedullary AC reconstruction and the other with an intramedullary AC reconstruction. We hypothesized intramedullary AC reconstruction will provide greater anteroposterior translational stability and improved load to failure characteristics than an extramedullary technique. Methods Six matched cadaveric shoulders underwent translational testing at 10 N and 15 N in the anteroposterior and superoinferior directions, under AC joint compression loads of 10 N, 20 N, and 30 N. After the AC and CC ligaments were transected, one of the specimens was randomly assigned the intramedullary free-tissue graft reconstruction while its matched pair received the extramedullary graft reconstruction. Both reconstructed specimens then underwent repeat translational testing, followed by load to failure testing, via superior clavicle distraction, at a rate of 50 mm/min. Results Intramedullary reconstruction provided significantly greater translational stability in the anteroposterior direction than the extramedullary technique for four of six loading conditions (p < 0.05). There were no significant differences in translational stability in the superoinferior direction for any loading condition. The intramedullary reconstructed specimens demonstrated improved load to failure characteristics with the intramedullary reconstruction having a lower deformation at yield and a higher ultimate load than the extramedullary reconstruction (p < 0.05). Conclusions Intramedullary reconstruction of the AC joint provides greater stability in the

  6. Factitious disorder as a differential diagnosis for recurrent skin graft failure.

    LENUS (Irish Health Repository)

    Seoighe, D M

    2011-04-01

    This case report presents the history of a 43-year-old man who sustained a relatively minor burn to his face but who subsequently suffered significant morbidity. Although the wound was grafted on a number of occasions, it failed to heal. Multiple investigations were carried out to determine the cause of recurrent wound breakdown. It had been suspected that the patient was interfering with the wound but this could not be proven initially. He was eventually diagnosed with factitious disorder and it was only when this was managed in the multi-disciplinary setting that his wound finally healed.

  7. Unexplained Graft Dysfunction after Heart Transplantation—Role of Novel Molecular Expression Test Score and QTc-Interval: A Case Report

    Directory of Open Access Journals (Sweden)

    Khurram Shahzad

    2010-01-01

    Full Text Available In the current era of immunosuppressive medications there is increased observed incidence of graft dysfunction in the absence of known histological criteria of rejection after heart transplantation. A noninvasive molecular expression diagnostic test was developed and validated to rule out histological acute cellular rejection. In this paper we present for the first time, longitudinal pattern of changes in this novel diagnostic test score along with QTc-interval in a patient who was admitted with unexplained graft dysfunction. Patient presented with graft failure with negative findings on all known criteria of rejection including acute cellular rejection, antibody mediated rejection and cardiac allograft vasculopathy. The molecular expression test score showed gradual increase and QTc-interval showed gradual prolongation with the gradual decline in graft function. This paper exemplifies that in patients presenting with unexplained graft dysfunction, GEP test score and QTc-interval correlate with the changes in the graft function.

  8. Mesh, graft, or standard repair for women having primary transvaginal anterior or posterior compartment prolapse surgery: two parallel-group, multicentre, randomised, controlled trials (PROSPECT).

    Science.gov (United States)

    Glazener, Cathryn Ma; Breeman, Suzanne; Elders, Andrew; Hemming, Christine; Cooper, Kevin G; Freeman, Robert M; Smith, Anthony Rb; Reid, Fiona; Hagen, Suzanne; Montgomery, Isobel; Kilonzo, Mary; Boyers, Dwayne; McDonald, Alison; McPherson, Gladys; MacLennan, Graeme; Norrie, John

    2017-01-28

    The use of transvaginal mesh and biological graft material in prolapse surgery is controversial and has led to a number of enquiries into their safety and efficacy. Existing trials of these augmentations are individually too small to be conclusive. We aimed to compare the outcomes of prolapse repair involving either synthetic mesh inlays or biological grafts against standard repair in women. We did two pragmatic, parallel-group, multicentre, randomised controlled trials for our study (PROSPECT [PROlapse Surgery: Pragmatic Evaluation and randomised Controlled Trials]) in 35 centres (a mix of secondary and tertiary referral hospitals) in the UK. We recruited women undergoing primary transvaginal anterior or posterior compartment prolapse surgery by 65 gynaecological surgeons in these centres. We randomly assigned participants by a remote web-based randomisation system to one of the two trials: comparing standard (native tissue) repair alone with standard repair augmented with either synthetic mesh (the mesh trial) or biological graft (the graft trial). We assigned women (1:1:1 or 1:1) within three strata: assigned to one of the three treatment options, comparison of standard repair with mesh, and comparison of standard repair with graft. Participants, ward staff, and outcome assessors were masked to randomisation where possible; masking was obviously not possible for the surgeon. Follow-up was for 2 years after the surgery; the primary outcomes, measured at 1 year and 2 years, were participant-reported prolapse symptoms (i.e. the Pelvic Organ Prolapse Symptom Score [POP-SS]) and condition-specific (ie, prolapse-related) quality-of-life scores, analysed in the modified intention-to-treat population. This trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN60695184. Between Jan 8, 2010, and Aug 30, 2013, we randomly allocated 1352 women to treatment, of whom 1348 were included in the analysis. 865 women were included in the mesh

  9. Hyponatraemia secondary to nivolumab-induced primary adrenal failure

    Directory of Open Access Journals (Sweden)

    Harris Trainer

    2016-11-01

    Full Text Available Checkpoint inhibitors, such as ipilimumab and pembrolizumab, have transformed the prognosis for patients with advanced malignant melanoma and squamous non-small-cell lung cancer, and their use will only expand as experience is gained in a variety of other malignancies, for instance, renal and lymphoma. As the use of checkpoint inhibitors increases, so too will the incidence of their unique side effects, termed immune-related adverse events (irAEs, which can affect dermatological, gastrointestinal, hepatic, endocrine and other systems. Nivolumab is a monoclonal antibody that blocks the human programmed death receptor-1 ligand (PD-L1 found on many cancer cells and is licensed for the treatment of advanced malignant melanoma. We describe the first case of nivolumab-induced adrenalitis resulting in primary adrenal failure presenting with hyponatraemia in a 43-year-old man with malignant melanoma. The case highlights the potentially life-threatening complications of checkpoint inhibitors and the need for patient education and awareness of irAEs among the wider clinical community because such side effects require prompt recognition and treatment.

  10. Effect of bidispersity in grafted chain length on grafted chain conformations and potential of mean force between polymer grafted nanoparticles in a homopolymer matrix.

    Science.gov (United States)

    Nair, Nitish; Wentzel, Nathaniel; Jayaraman, Arthi

    2011-05-21

    In efforts to produce polymeric materials with tailored physical properties, significant interest has grown around the ability to control the spatial organization of nanoparticles in polymer nanocomposites. One way to achieve controlled particle arrangement is by grafting the nanoparticle surface with polymers that are compatible with the matrix, thus manipulating the interfacial interactions between the nanoparticles and the polymer matrix. Previous work has shown that the molecular weight of the grafted polymer, both at high grafting density and low grafting density, plays a key role in dictating the effective inter-particle interactions in a polymer matrix. At high grafting density nanoparticles disperse (aggregate) if the graft molecular weight is higher (lower) than the matrix molecular weight. At low grafting density the longer grafts can better shield the nanoparticle surface from direct particle-particle contacts than the shorter grafts and lead to the dispersion of the grafted particles in the matrix. Despite the importance of graft molecular weight, and evidence of non-trivial effects of polydispersity of chains grafted on flat surfaces, most theoretical work on polymer grafted nanoparticles has only focused on monodisperse grafted chains. In this paper, we focus on how bidispersity in grafted chain lengths affects the grafted chain conformations and inter-particle interactions in an implicit solvent and in a dense homopolymer polymer matrix. We first present the effects of bidispersity on grafted chain conformations in a single polymer grafted particle using purely Monte Carlo (MC) simulations. This is followed by calculations of the potential of mean force (PMF) between two grafted particles in a polymer matrix using a self-consistent Polymer Reference Interaction Site Model theory-Monte Carlo simulation approach. Monte Carlo simulations of a single polymer grafted particle in an implicit solvent show that in the bidisperse polymer grafted particles

  11. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  12. Pre- and Posttransplant IgA Anti-Fab Antibodies to Predict Long-term Kidney Graft Survival.

    Science.gov (United States)

    Amirzargar, M A; Amirzargar, A; Basiri, A; Hajilooi, M; Roshanaei, G; Rajabi, G; Solgi, G

    2015-05-01

    Immunologic factors are reliable markers for allograft monitoring, because of their seminal role in rejection process. One of these factors is the immunoglobulin (Ig)A anti-Fab of the IgG antibody. This study aimed to evaluate the predictive value of pre- and posttransplant levels of this marker for kidney allograft function and survival. Sera samples of 59 living unrelated donor kidney recipients were collected before and after transplantation (days 7, 14, and 30) and investigated for IgA anti-Fab of IgG antibody levels using enzyme-linked immunosorbent assay in relation with allograft outcome. Among 59 patients, 15 cases (25%) including 10 with acute rejection and 5 with chronic rejection episodes showed graft failure during a mean of 5 years of follow-up. High posttransplant levels of IgA anti-Fab antibodies were observed more frequently in patients with stable graft function (SGF) compared with patients with graft failure (P = 2 × 10(-6)). None of patients with acute or chronic rejection episodes had high levels of IgA anti-Fab antibodies at day 30 posttransplant compared with the SGF group (P = 10(-6) and P = .01, respectively). In addition, high levels of IgA anti-Fab antibody correlated with lesser concentration of serum creatinine at 1 month posttransplantation (P = .01). Five-year graft survival was associated with high levels of pre- and posttransplant IgA anti-Fab antibodies (P = .02 and P = .003, respectively). Our findings indicate the protective effect of higher levels of IgA anti-Fab antibodies regarding to kidney allograft outcomes and long-term graft survival. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Tibial tunnel and pretibial cysts following ACL graft reconstruction: MR imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ghazikhanian, Varand [Brigham and Women' s Hospital, Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Beltran, Javier [Maimonides Medical Center, Brooklyn, NY (United States); Nikac, Violeta [Maimonides Medical Center, Department of Radiology, Brooklyn, NY (United States); Bencardino, Jenny T. [NYU Hospital for Joint Diseases, New York, NY (United States); Feldman, Marina

    2012-11-15

    Tunnel cyst formation is a rare complication after anterior cruciate ligament reconstruction, usually occurring 1-5 years post-operatively, which may occasionally be symptomatic. There are multiple proposed theories regarding the etiology of tunnel cysts. Theories include necrosis, foreign-body reaction, lack of complete graft osteo-integration, and intravasation of articular fluid. It is important to know if the tunnel cysts are communicating or not communicating with the joint, as surgical management may be different. Imaging characteristics on magnetic resonance images (MRI) include tibial tunnel widening, multilocular or unilocular cyst formation in the graft or tibial tunnel, with possible extension into the pretibial space, intercondylar notch, and/or popliteal fossa. The MR imaging differential diagnosis of tibial tunnel cysts includes infection, foreign-body granuloma, or tibial screw extrusion. Importantly, to the best of our knowledge, graft failure or instability has not been reported in association with tibial tunnel cysts. (orig.)

  14. Stability of dental implants in grafted bone in the anterior maxilla: longitudinal study.

    LENUS (Irish Health Repository)

    Al-Khaldi, Nasser

    2010-06-06

    We aimed to assess the stability over time of dental implants placed in grafted bone in the maxilla using resonance frequency analysis, and to compare the stability of implants placed in grafted and non-grafted bone. Data were collected from 23 patients (15 test and 8 controls) in whom 64 implants (Brånemark system, Nobel Biocare, Göteborg, Sweden) were placed in accordance with the two-stage surgical protocol. In the test group 36 fixtures were placed in grafted bone, and in the control group 28 fixtures were placed in non-grafted bone. Resonance frequency analysis was used to assess the test sites at implant placement and abutment connection. The mean (SD) implant stability quotient (ISQ) for test sites at the time of implant placement was 61.91 (6.68), indicating excellent primary stability, and was 63.53 (5.76) at abutment connection. ISQ values at abutment connection were similar for test and control sites. Implants placed in grafted bone compared favourably with those in non-grafted bone, and showed excellent stability.

  15. Buccal mucosal graft urethroplasty in men-risk factors for recurrence and complications: a third referral centre experience in anterior urethroplasty using buccal mucosal graft.

    Science.gov (United States)

    Spilotros, Marco; Sihra, Neha; Malde, Sachin; Pakzad, Mahreen H; Hamid, Rizwan; Ockrim, Jeremy L; Greenwell, Tamsin J

    2017-06-01

    Urethral stricture disease is a challenging condition to treat and several approaches including direct visual internal urethrotomy (DVIU) and anastomotic or augmentation urethroplasties based on the use of flaps and graft have been reported. The aim of this study is to determine risk factors for stricture recurrence and complications in patients having buccal mucosal graft (BMG) urethroplasty for anterior urethral stricture under a single surgeon in a third referral centre in UK. We conducted a retrospective review of a prospectively gathered database of 128 patients having various forms of BMG urethroplasty between 2001 and 2015. Success and failure in terms of stricture recurrence, patient demographics, stricture aetiology and anatomy, and the adverse outcomes of: post-micturition dribbling (PMD), erectile dysfunction (ED) >12 months and complications were recorded in order to determine risk factors for recurrent stricture and complications. The mean age of all patients was 42.8 years (range, 16-74 years). Average follow-up was 45 months (range, 3-159 months). The total re-stricture rate was 19% (24 men). PMD was reported in 16% (n=20) and ED in 12.5% (n=16). All ED was none organic and responded to oral PDE5 inhibitor treatment. Post-operative complications were reported in 16 patients (12.5%). The most frequent complications recorded were urinary fistula (n=4; 3.1%), graft contracture (n=4; 3.1%) and graft failure (n=4; 3.1%), all reported after penile urethroplasty. Univariate analysis indicated that age at surgery, stricture length, site and aetiology were all significant risk factors for stricture recurrence. On multivariate analysis penile site was the only significant independent variable for restricture. BMG urethroplasty represents a reliable therapeutic option for patient with urethral strictures with a success rate of 81% at 45 months of follow-up. Complications are more common in complex stricture of the penile urethra. On multivariate analysis penile

  16. Buccal mucosal graft urethroplasty in men—risk factors for recurrence and complications: a third referral centre experience in anterior urethroplasty using buccal mucosal graft

    Science.gov (United States)

    Sihra, Neha; Malde, Sachin; Pakzad, Mahreen H.; Hamid, Rizwan; Ockrim, Jeremy L.; Greenwell, Tamsin J.

    2017-01-01

    Background Urethral stricture disease is a challenging condition to treat and several approaches including direct visual internal urethrotomy (DVIU) and anastomotic or augmentation urethroplasties based on the use of flaps and graft have been reported. The aim of this study is to determine risk factors for stricture recurrence and complications in patients having buccal mucosal graft (BMG) urethroplasty for anterior urethral stricture under a single surgeon in a third referral centre in UK. Methods We conducted a retrospective review of a prospectively gathered database of 128 patients having various forms of BMG urethroplasty between 2001 and 2015. Success and failure in terms of stricture recurrence, patient demographics, stricture aetiology and anatomy, and the adverse outcomes of: post-micturition dribbling (PMD), erectile dysfunction (ED) >12 months and complications were recorded in order to determine risk factors for recurrent stricture and complications. Results The mean age of all patients was 42.8 years (range, 16–74 years). Average follow-up was 45 months (range, 3–159 months). The total re-stricture rate was 19% (24 men). PMD was reported in 16% (n=20) and ED in 12.5% (n=16). All ED was none organic and responded to oral PDE5 inhibitor treatment. Post-operative complications were reported in 16 patients (12.5%). The most frequent complications recorded were urinary fistula (n=4; 3.1%), graft contracture (n=4; 3.1%) and graft failure (n=4; 3.1%), all reported after penile urethroplasty. Univariate analysis indicated that age at surgery, stricture length, site and aetiology were all significant risk factors for stricture recurrence. On multivariate analysis penile site was the only significant independent variable for restricture. Conclusions BMG urethroplasty represents a reliable therapeutic option for patient with urethral strictures with a success rate of 81% at 45 months of follow-up. Complications are more common in complex stricture of the

  17. SUPPLEMENTAL CARDIOPLEGIA IMMEDIATELY BEFORE GRAFT IMPLANTATION MAY IMPROVE EARLY POST-TRANSPLANTATION OUTCOME

    Directory of Open Access Journals (Sweden)

    Hendrik eTevaearai Stahel

    2014-11-01

    Full Text Available Background: Preservation of cardiac grafts for transplantation is not standardized and most centers use a single administration of crystalloid solution at the time of harvesting. We investigated possible benefits of an additional dose of cardioplegia dispensed immediately before implantation.Methods: Consecutive adult cardiac transplantations (2005-2012 were reviewed. Hearts were harvested following a standard protocol (Celsior 2L, 4-8oC. In 2008, 100mL crystalloid cardioplegic solution was added and administered immediately before implantation. Univariate and logistic regression analyses were used to investigate risk factors for post-operative graft failure and mid-term outcome. Results: A total of 81 patients, 44 standard (Cardio - versus 37 with additional cardioplegia (Cardio + were analyzed. Recipients and donors were comparable in both groups. Cardio + patients demonstrated a reduced need for defibrillation (24% vs. 48%, p=0.03, post-operative ratio of CK-MB/CK (10.1±3.9% vs. 13.3±4.2%, p=0.001, intubation time (2.0±1.6 vs. 7.2±11.5 days, p=0.05 and ICU stay (3.9±2.1 vs. 8.5±7.8 days, p=0.001. Actuarial survival was reduced when graft ischemic time was >180 minutes in Cardio – but not in Cardio + patients (p=0.033. Organ ischemic time >180 minutes (OR:5.48, CI:1.08-27.75, donor female gender (OR:5.84, CI:1.13-33.01 and recipient/donor age >60 (OR:6.33, CI:0.86-46.75, but not the additional cardioplegia nor the observation period appeared independent predictors of post-operative acute graft failure.Conclusion: An additional dose of cardioplegia administered immediately before implantation may be a simple way to improve early and late outcome of cardiac transplantation, especially in situations of prolonged graft ischemia. A large, ideally multicentric, randomized study is desirable to verify this preliminary observation.

  18. Preliminary in Vivo Evaluation of a Hybrid Armored Vascular Graft Combining Electrospinning and Additive Manufacturing Techniques

    Directory of Open Access Journals (Sweden)

    Cristiano Spadaccio

    2016-01-01

    Full Text Available In this study, we tested in vivo effectiveness of a previously developed poly-L-lactide/poly-8-caprolactone armored vascular graft releasing heparin. This bioprosthesis was designed in order to overcome the main drawbacks of tissue-engineered vascular grafts, mainly concerning poor mechanical properties, thrombogenicity, and endothelialization. The bioprosthesis was successfully implanted in an aortic vascular reconstruction model in rabbits. All grafts implanted were patent at four weeks postoperatively and have been adequately populated by endogenous cells without signs of thrombosis or structural failure and with no need of antiplatelet therapy. The results of this preliminary study might warrant for further larger controlled in vivo studies to further confirm these findings.

  19. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  20. Rationale, design and baseline results of the Treatment Optimisation in Primary care of Heart failure in the Utrecht region (TOPHU) study : a cluster randomised controlled trial

    NARCIS (Netherlands)

    Valk, Mark J.; Hoes, Arno W.; Mosterd, Arend; Landman, Marcel A.; Broekhuizen, Berna D L; Rutten, Frans H.

    2015-01-01

    BACKGROUND: Heart failure (HF) is mainly detected and managed in primary care, but the care is considered suboptimal. We present the rationale, design and baseline results of the Treatment Optimisation in Primary care of Heart failure in the Utrecht region (TOPHU) study. In this study we assess the

  1. Proteomic Profiling in Early Venous Stenosis Formation in a Porcine Model of Hemodialysis Graft

    Science.gov (United States)

    Misra, Sanjay; Fu, Alex A.; Puggioni, Alessandra; Glockner, James F.; McKusick, Michael A.; Bjarnason, Haraldur; Mukhopadhyay, Debabrata

    2009-01-01

    PURPOSE To use proteomic analysis to identify up- and downregulated proteins in early venous stenosis formation in a porcine model of hemodialysis graft failure. MATERIALS AND METHODS Pigs had chronic renal insufficiency created by subtotal renal infarction caused by renal artery embolization. Arteriovenous polytetrafluoroethylene grafts were placed 28 days later and the animals were killed after a further 3 days (n = 4), 7 days (n = 4), or 14 days (n = 4). Proteomic analysis with isotope-coded affinity tags and multidimensional liquid chromatography followed by tandem mass spectrometry was performed on the venous stenosis and control vessels. Expression of proteins was further confirmed by Western blot analysis. The blood urea nitrogen (BUN) and creatinine levels were determined before renal artery embolization and at the time of graft placement. RESULTS At graft placement, mean BUN and creatinine levels were significantly higher than before embolization (P < .05). Six proteins were identified that were common to all four animals at the same time point. Five proteins (α-fetoprotein, fetuin A, macrophage migration inhibitory factor, pyruvate dehydrogenase E1 component, and lactoferrin) were upregulated and one protein (decorin) was downregulated. Expression of macrophage migration inhibitory factor, α-fetoprotein, and lactoferrin was further validated with Western blotting. By day 14, lactoferrin and fetuin-A expression were increased significantly in early venous stenosis formation. CONCLUSIONS Significantly increased expression of lactoferrin and fetuin-A were observed in early venous stenosis by day 14. Understanding the role of lactoferrin and fetuin-A in hemodialysis vascular access failure could help in improving outcomes in patients undergoing hemodialysis. PMID:19028119

  2. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  3. Primary skeletal muscle myoblasts from chronic heart failure patients exhibit loss of anti-inflammatory and proliferative activity

    NARCIS (Netherlands)

    Sente, T.; Berendoncks, A.M. Van; Jonckheere, A.I.; Rodenburg, R.J.T.; Lauwers, P.; Hoof, V. Van; Wouters, A.; Lardon, F.; Hoymans, V.Y.; Vrints, C.J.

    2016-01-01

    BACKGROUND: Peripheral skeletal muscle wasting is a common finding with adverse effects in chronic heart failure (HF). Whereas its clinical relevance is beyond doubt, the underlying pathophysiological mechanisms are not yet fully elucidated. We aimed to introduce and characterize the primary culture

  4. Revascularization of autogenous skin grafts placed on irradiated tissue

    International Nuclear Information System (INIS)

    Ueda, M.; Torii, S.; Kaneda, T.; Oka, T.

    1982-01-01

    Vascular changes in rat skin after irradiation were examined microangiographically. Revascularization of the skin transplanted during the chronic stage after irradiation was also studied. The results obtained through these examinations revealed higher vascular densities at the acute and the subacute stages, and low values at the chronic stages compared with those of the control. Furthermore, when the skin grafts were transplanted to the irradiated beds in the chronic stage, primary revascularization was scant, and the inhibited capillary proliferation in the recipient sites prevented new vessel penetration. This explains why grafts transplanted to previously irradiated beds fail to survive

  5. Rule-based model of vein graft remodeling.

    Directory of Open Access Journals (Sweden)

    Minki Hwang

    Full Text Available When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC, extracellular matrix (ECM, and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.

  6. [Revascularization surgery of an anuric solitary kidney using the left colic artery as a free graft].

    Science.gov (United States)

    da Gama, A Dinis; Nunes, J Silva; Cunha e Sá, Diogo; Pedro, Luís Mendes

    2003-01-01

    The thrombotic occlusion of one renal artery may become completely asymptomatic, due to the functionality of the contralateral kidney. However, in rare circumstances, such is the case of individuals with a solitary kidney, a situation of anuria and acute renal failure may constitute the main presentation of the condition. The authors report the clinical case of a 43 year old male patient, with the previous diagnosis of an infrarenal aortic occlusion and a single left kidney, who developed a thrombotic occlusion of the renal artery, with anuria and acute renal failure. The patient underwent an emergency revascularization procedure, consisting in the implantation of a prosthetic bypass graft from the superceliac aorta to the renal artery, with immediate recovery of the diuresis and renal function. Seventeen months later as a consequence of an anastomotic hyperplasia, an occlusion of the bypass graft occurred, again with anuria and acute renal failure. The patient was reoperated on and due to the inadequacy of both saphenous veins to be used as the material of choice for the revascularization procedure, a redundant segment of the left colic artery (Riolan's arcade) was removed and used as an interposition graft, from the middle colic artery to the renal artery, followed by an immediate restoration of diuresis and renal function. The singular and recurrent character of this clinical condition and the utilization of an original, eventually unique and well succeeded revascularization procedure, prompted its presentation and divulgation.

  7. Heart retransplantation: a 23-year single-center clinical experience.

    Science.gov (United States)

    Schnetzler, B; Pavie, A; Dorent, R; Camproux, A C; Leger, P; Delcourt, A; Gandjbakhch, I

    1998-04-01

    The main causes of allograft failure after cardiac transplantation are primary graft dysfunction, intractable acute rejection, and coronary graft disease. Despite the important progress in the last several years in graft preservation, surgical techniques, immunosuppression, and treatment of coronary graft disease, retransplantation in selected cases is the only way to achieve long-term recipient survival. We compare here in a case-control study 24 retransplantations with 47 first transplants in patients matched for date of transplantation. Between 1973 and 1996, 1,063 patients underwent cardiac transplantation in our institution. In this cohort, 22 patients had a total of 24 retransplantations (2 second-time retransplantations). The causes of retransplantations were primary graft failure (n=4), acute rejection (n=7), coronary graft disease (n=11), and miscellaneous (n=2). Survival at 1 and 5 years of patients with retransplantations is 45.5% and 31.2%, and survival of control patients is 59.4% and 38.8% (p=0.07). An interval between first transplantation and retransplantation shorter (n=11) or longer (n=13) than 1 year is associated with a 1-year survival of 27.3% and 61.5% and a 4-year survival of 27.3% and 46%, respectively (not significant). Intervals shorter than 1 year between first transplantation and retransplantation were exclusively secondary to primary graft failure or intractable acute rejection. In the face of lack of donor grafts, these and other data indicate that retransplantation should be considered cautiously, especially when the interval between the first transplantation and retransplantation is short.

  8. Negative pressure wound therapy using polyvinyl alcohol foam to bolster full-thickness mesh skin grafts in dogs.

    Science.gov (United States)

    Or, Matan; Van Goethem, Bart; Kitshoff, Adriaan; Koenraadt, Annika; Schwarzkopf, Ilona; Bosmans, Tim; de Rooster, Hilde

    2017-04-01

    To report the use of negative pressure wound therapy (NPWT) with polyvinyl alcohol (PVA) foam to bolster full-thickness mesh skin grafts in dogs. Retrospective case series. Client-owned dogs (n = 8). Full-thickness mesh skin graft was directly covered with PVA foam. NPWT was maintained for 5 days (in 1 or 2 cycles). Grafts were evaluated on days 2, 5, 10, 15, and 30 for graft appearance and graft take, granulation tissue formation, and complications. Firm attachment of the graft to the recipient bed was accomplished in 7 dogs with granulation tissue quickly filling the mesh holes, and graft take considered excellent. One dog had bandage complications after cessation of the NPWT, causing partial graft loss. The PVA foam did not adhere to the graft or damage the surrounding skin. The application of NPWT with a PVA foam after full-thickness mesh skin grafting in dogs provides an effective method for securing skin grafts, with good graft acceptance. PVA foam can be used as a primary dressing for skin grafts, obviating the need for other interposing materials to protect the graft and the surrounding skin. © 2017 The American College of Veterinary Surgeons.

  9. Long-term follow-up in optimally treated and stable heart failure patients: primary care vs. heart failure clinic. Results of the COACH-2 study.

    Science.gov (United States)

    Luttik, Marie Louise A; Jaarsma, Tiny; van Geel, Peter Paul; Brons, Maaike; Hillege, Hans L; Hoes, Arno W; de Jong, Richard; Linssen, Gerard; Lok, Dirk J A; Berge, Marjolein; van Veldhuisen, Dirk J

    2014-11-01

    It has been suggested that home-based heart failure (HF) management in primary care may be an alternative to clinic-based management in HF patients. However, little is known about adherence to HF guidelines and adherence to the medication regimen in these home-based programmes. The aim of the current study was to determine whether long-term follow-up and treatment in primary care is equally effective as follow-up at a specialized HF clinic in terms of guideline adherence and patient adherence, in HF patients initially managed and up-titrated to optimal treatment at a specialized HF clinic. We conducted a multicentre, randomized, controlled study in 189 HF patients (62% male, age 72 ± 11 years), who were assigned to follow-up either in primary care (n = 97) or in a HF clinic (n = 92). After 12 months, no differences between guideline adherence, as estimated by the Guideline Adherence Indicator (GAI-3), and patient adherence, in terms of the medication possession ratio (MPR), were found between treatment groups. There was no difference in the number of deaths (n = 12 in primary care and n = 8 in the HF clinic; P = 0.48), and hospital readmissions for cardiovascular (CV) reasons were also similar. The total number of unplanned non-CV hospital readmissions, however, tended to be higher in the primary care group (n = 22) than in the HF clinic group (n = 10; P = 0.05). Patients discharged after initial management in a specialized HF clinic can be discharged to primary care for long-term follow-up with regard to maintaining guideline adherence and patient adherence. However, the complexity of the HF syndrome and its associated co-morbidities requires continuous monitoring. Close collaboration between healthcare providers will be crucial in order to provide HF patients with optimal, integrated care. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.

  10. The significance of parenchymal changes of acute cellular rejection in predicting chronic liver graft rejection

    NARCIS (Netherlands)

    Gouw, ASH; van den Heuvel, MC; van den Berg, AP; Slooff, NJH; de Jong, KP; Poppema, S

    2002-01-01

    Background. Chronic rejection (CR) in liver allografts shows a rapid onset and progressive course, leading to graft failure within the first year after transplantation. Most cases are preceded by episodes of acute cellular rejection (AR), but histological features predictive for the transition

  11. USE OF CORTICAL BONE FENESTRATION, AUTOGENOUS FREE SKIN GRAFT, AND THERMOGRAPHY FOR WOUND TREATMENT AND MONITORING IN A RED WOLF (CANIS RUFUS GREGORYI).

    Science.gov (United States)

    Hurley-Sanders, Jennifer L; Sladky, Kurt K; Nolan, Elizabeth C; Loomis, Michael R

    2015-09-01

    A 2-yr-old female red wolf (Canis rufus gregoryi) sustained a degloving injury to the left thoracic limb while in a display habitat. Initial attempts to resolve the extensive wound by using conservative measures were unsuccessful. Subsequent treatment using a free skin graft consisted first of establishment of an adequate granulation bed via cortical bone fenestration. After establishment of a healthy granulation bed was achieved, free skin graft was harvested and transposed over the bed. To monitor viability and incorporation of the graft, serial thermographic imaging was performed. Thermography noninvasively detects radiant heat patterns and can be used to assess vascularization of tissue, potentially allowing early detection of graft failure. In this case, thermography documented successful graft attachment.

  12. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  13. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  14. Engineering the mechanical and biological properties of nanofibrous vascular grafts for in situ vascular tissue engineering.

    Science.gov (United States)

    Henry, Jeffrey J D; Yu, Jian; Wang, Aijun; Lee, Randall; Fang, Jun; Li, Song

    2017-08-17

    Synthetic small diameter vascular grafts have a high failure rate, and endothelialization is critical for preventing thrombosis and graft occlusion. A promising approach is in situ tissue engineering, whereby an acellular scaffold is implanted and provides stimulatory cues to guide the in situ remodeling into a functional blood vessel. An ideal scaffold should have sufficient binding sites for biomolecule immobilization and a mechanical property similar to native tissue. Here we developed a novel method to blend low molecular weight (LMW) elastic polymer during electrospinning process to increase conjugation sites and to improve the mechanical property of vascular grafts. LMW elastic polymer improved the elasticity of the scaffolds, and significantly increased the amount of heparin conjugated to the micro/nanofibrous scaffolds, which in turn increased the loading capacity of vascular endothelial growth factor (VEGF) and prolonged the release of VEGF. Vascular grafts were implanted into the carotid artery of rats to evaluate the in vivo performance. VEGF treatment significantly enhanced endothelium formation and the overall patency of vascular grafts. Heparin coating also increased cell infiltration into the electrospun grafts, thus increasing the production of collagen and elastin within the graft wall. This work demonstrates that LMW elastic polymer blending is an approach to engineer the mechanical and biological property of micro/nanofibrous vascular grafts for in situ vascular tissue engineering.

  15. Graft irradiation abrogates graft-versus-host disease in combined pancreas-spleen transplantation

    International Nuclear Information System (INIS)

    Schulak, J.A.; Sharp, W.J.

    1986-01-01

    A model of combined pancreas-spleen transplantation (PST) was studied in LBN F1 recipients of Lewis grafts in order to evaluate the efficacy of pretransplant graft irradiation in preventing lethal graft-versus-host disease (GVHD). Recipients of unmodified PST uniformly developed severe GVHD and died (MST = 16.7 +/- 3.8 days). Whole body donor irradiation with either 500 or 250 rad prevented lethal GVHD. Similarly, ex vivo graft irradiation with either 1000 or 500 rad also resulted in normal weight gain, graft function, and host survival for the 6-week study period. Conversely, delay of graft irradiation until 3 days after transplantation failed to prevent this complication (MST = 15.8 +/- 3.7 days). Recipients of irradiated grafts displayed glucose tolerance tests that were identical to those in the control group indicating that the doses of radiation employed in these experiments were not deleterious to islet function. Irradiated spleen grafts appeared histologically normal at 6 weeks after transplantation. Cells derived from these grafts failed to stimulate lymph node enlargement in a popliteal lymph node assay for GVHD, suggesting that these spleens may have become repopulated with host cells. These experiments confirm that PST has the potential to cause lethal GVHD and suggest that pretransplant graft irradiation may be used to prevent its occurrence

  16. Proximal Tibia Bone Graft: An alternative Donor Source especially for Foot and Ankle Procedures

    Directory of Open Access Journals (Sweden)

    Jia TY

    2015-03-01

    Full Text Available Among the many donor sites for harvesting autologous bone graft, the iliac crest has been the most commonly used. However, for foot and ankle procedures the proximal tibia has gained popularity as an alternative donor site due to its anatomic proximity to the primary surgical site. In this article we evaluated the possible complications associated with harvesting proximal tibia bone graft. Our study showed the low incidence of morbidity in harvesting proximal tibia bone graft, thereby providing a good alternative donor for foot and ankle procedures.

  17. Effect of Grafting Method, Graft Cover and Foliar Spray of some Mineral Elements on Persian Walnut Graft-take and Winter Survival Rate

    Directory of Open Access Journals (Sweden)

    Reza Rezaee

    2017-09-01

    Full Text Available Introduction: Persian walnut (Juglans regia L. is an important nut crop in Iran and many parts of the world. One of the major challenges of growing walnut is planting of non-grafted walnut trees in orchards, which leads to the reduction of yield, quality and productivity of walnut orchards. Compared to the other fruit trees, walnut grafting is difficult and even newly grafted walnut seedlings are vulnerable to fall or winter frost chilling, so that most of the seedlings are lost after subjecting to the cold winter. There are a few studies reporting successful grafting in outdoor conditions, however, final grafting take after winter has been usually ignored. Hence, increased walnut grafting success and improved tree growth after grafting through foliar nutrient application may lead to increased tolerance of chilling. Therefore, main goals of this research were to investigate the effect of some graft covers and role of foliar spray of calcium, boron and zinc on the reduction of frost damage in newly grafted seedlings under outdoor conditions. Materials and methods: This research was conducted at agricultural research station, Khoy city, west Azerbaijan province, during 2012-2014. In the first experiment, three methods of grafting including cleft, bark and V-shaped, and two kinds of graft covers including moist sawdust and superabsorbent plus cotton wool were investigated in terms of grafting success and quality of seedlings. In the second experiment, effect of the three above-mentioned grafting methods and two levels of foliar spray including sequential spray of Ca (4 ppm, B and Zn (2% (3 times during growth season and control (no spray were studied in terms of frost damage. The experiments conducted in factorial based on randomized complete block design with 10 trees in each plot. Data were collected 45 days after grafting take, final grafting take after one winter, subsequent scion growth length and diameter and concentration of Ca, B and Zn in

  18. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  19. Delayed grafting for banked skin graft in lymph node flap transfer.

    Science.gov (United States)

    Ciudad, Pedro; Date, Shivprasad; Orfaniotis, Georgios; Dower, Rory; Nicoli, Fabio; Maruccia, Michele; Lin, Shu-Ping; Chuang, Chu-Yi; Chuang, Tsan-Yu; Wang, Gou-Jen; Chen, Hung-Chi

    2017-02-01

    Over the last decade, lymph node flap (LNF) transfer has turned out to be an effective method in the management of lymphoedema of extremities. Most of the time, the pockets created for LNF cannot be closed primarily and need to be resurfaced with split thickness skin grafts. Partial graft loss was frequently noted in these cases. The need to prevent graft loss on these iatrogenic wounds made us explore the possibility of attempting delayed skin grafting. We have herein reported our experience with delayed grafting with autologous banked split skin grafts in cases of LNF transfer for lymphoedema of the extremities. Ten patients with International Society of Lymphology stage II-III lymphoedema of upper or lower extremity were included in this study over an 8-month period. All patients were thoroughly evaluated and subjected to lymph node flap transfer. The split skin graft was harvested and banked at the donor site, avoiding immediate resurfacing over the flap. The same was carried out in an aseptic manner as a bedside procedure after confirming flap viability and allowing flap swelling to subside. Patients were followed up to evaluate long-term outcomes. Flap survival was 100%. Successful delayed skin grafting was done between the 4th and 6th post-operative day as a bedside procedure under local anaesthesia. The split thickness skin grafts (STSG) takes more than 97%. One patient needed additional medications during the bedside procedure. All patients had minimal post-operative pain and skin graft requirement. The patients were also reported to be satisfied with the final aesthetic results. There were no complications related to either the skin grafts or donor sites during the entire period of follow-up. Delayed split skin grafting is a reliable method of resurfacing lymph node flaps and has been shown to reduce the possibility of flap complications as well as the operative time and costs. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  1. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  2. Treatment for long bulbar urethral strictures with membranous involvement using urethroplasty with oral mucosa graft.

    Science.gov (United States)

    Gimbernat, H; Arance, I; Redondo, C; Meilán, E; Andrés, G; Angulo, J C

    2014-10-01

    Urethroplasty with oral mucosa grafting is the most popular technique for treating nontraumatic bulbar urethral strictures; however, cases involving the membranous portion are usually treated using progressive perineal anastomotic urethroplasty. We assessed the feasibility of performing dorsal (or ventral) graft urethroplasty on bulbar urethral strictures with mainly membranous involvement using a modified Barbagli technique. This was a prospective study of 14 patients with bulbomembranous urethral strictures who underwent dilation urethroplasty with oral mucosa graft between 2005 and 2013, performed using a modified technique Barbagli, with proximal anchoring of the graft and securing of the graft to the tunica cavernosa in 12 cases (85.7%) and ventrally in 2 (14.3%). The minimum follow-up time was 1 year. We evaluated the subjective (patient satisfaction) and objective (maximum flow [Qmax] and postvoid residual volume [PVRV], preoperative and postoperative) results and complications. Failure was defined as the need for any postoperative instrumentation. A total of 14 patients (median age, 64+13 years) underwent surgery. The main antecedent of note was transurethral resection of the prostate in 9 cases (64.3%). The median length of the stenosis was 45+26.5mm. Prior to surgery, 50% of the patients had been subjected to dilatations and 4% to endoscopic urethrotomy. The mean surgical time and hospital stay were was 177+76min and 1.5+1 day, respectively. The preoperative Qmax and PVRV values were 4.5+4.45mL/sec and 212.5+130 cc, respectively. The postoperative values were 15.15+7.2mL/sec and 6+21.5cc, respectively (Purethroplasty with free oral mucosa grafts represents a viable alternative for patients with nontraumatic etiology and little fibrosis. The dilation of the urethral lumen achieves good results with minimum failure rates and little probability of complications. For many of these patients, the length of the stricture is too long to perform the tension

  3. [Effectiveness of vacuum sealing drainage combined with anti-taken skin graft for primary closing of open amputation wound].

    Science.gov (United States)

    Liao, Qiande; Xu, Jian; Weng, Xiao-Jun; Zhong, Da; Liu, Zhiqin; Wang, Chenggong

    2012-05-01

    To observe the effectiveness of vacuum sealing drainage (VSD) combined with anti-taken skin graft on open amputation wound by comparing with direct anti-taken skin graft. Between March 2005 and June 2010, 60 cases of amputation wounds for limbs open fractures were selected by using the random single-blind method. The amputation wounds were treated with VSD combined with anti-taken skin graft (test group, n = 30) and direct anti-taken skin graft (control group, n = 30). No significant difference was found in age, gender, injury cause, amputation level, defect size, preoperative albumin index, or injury time between 2 groups (P > 0.05). In test group, the redundant stump skin was used to prepare reattached staggered-meshed middle-thickness skin flap by using a drum dermatome dealing after amputation, which was transplanted amputation wounds, and then the skin surface was covered with VSD for continuous negative pressure drainage for 7-10 days. In control group, wounds were covered by anti-taken thickness skin flap directly after amputation, and conventional dress changing was given. To observe the survival condition of the skin graft in test group, the VSD device was removed at 8 days after operation. The skin graft survival rate, wound infection rate, reamputation rate, times of dressing change, and the hospitalization days in test group were significantly better than those in control group [ 90.0% vs. 63.3%, 3.3% vs. 20.0%, 0 vs. 13.3%, (2.0 +/- 0.5) times vs. (8.0 +/- 1.5) times, and (12.0 +/- 2.6) days vs. (18.0 +/- 3.2) days, respectively] (P 0.05). In comparison with the contralateral limbs, the muscle had disuse atrophy and decreased strength in residual limbs of 2 groups. There was significant difference in the muscle strength between normal and affected limbs (P 0.05). Compared with direct anti-taken skin graft on amputation wound, the wound could be closed primarily by using the VSD combined with anti-taken skin graft. At the same time it could achieve

  4. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Bakhru, Prashant [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Park, Brian [Albert Einstein College of Medicine, Bronx, NY (United States); Umans, Hilary [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States); DiFelice, Gregory S. [Hospital for Special Surgery, New York, NY (United States); Tobin, Keith [Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States)

    2011-06-15

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  5. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    International Nuclear Information System (INIS)

    Bakhru, Prashant; Park, Brian; Umans, Hilary; DiFelice, Gregory S.; Tobin, Keith

    2011-01-01

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  6. In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3.

    Science.gov (United States)

    Han, D K; Lee, K B; Park, K D; Kim, C S; Jeong, S Y; Kim, Y H; Kim, H M; Min, B G

    1993-01-01

    PU-PEO-SO3 was applied as a coating material over a newly designed Sinkhole bileaflet PU heart valve and a porous PU vascular graft. Performance and biocompatibility were evaluated using an in vivo canine shunt system between the right ventricle and pulmonary artery. The survival periods in three implantations were 14, 24, and 39 days, during which no mechanical failure occurred in any Sinkhole valve or vascular graft. Scanning electron microscopy (SEM) studies demonstrated much less platelet adhesion and thrombus formation on PU-PEO-SO3 grafts than on PU vascular grafts. Cracks in the valve leaflet were occasionally observed on PU surfaces, but not on PU-PEO-SO3. After a 39 day implantation, calcium deposition on vascular grafts was decreased as compared with valve leaflets, and calcification on PU-PEO-SO3 was much lower than on PU. These results suggest that Sinkhole valves and vascular grafts are promising, and PU-PEO-SO3 as a coating material is more blood compatible, biostable, and calcification resistant in vivo than in untreated PU.

  7. Evaluation of Replacement Grafts and Punch Grafts in the Treatment of Vitiligo

    Directory of Open Access Journals (Sweden)

    Singh Ajit Kumar

    1980-01-01

    Full Text Available Thirtycasesof vitiligo eachwithminimum of two lesions undent replacement graft and multiple punch grafts in one lesion each. Complications observed at the recipient site like infection and raised nigosed surface were significantly more in replacement grafts. Hypopigmentation of the graft was significantly more when the disease was progressive.

  8. Improved biocompatibility but limited graft survival after purification of alginate for microencapsulation of pancreatic islets

    NARCIS (Netherlands)

    DeVos, P; DeHaan, BJ; Wolters, GHJ; Strubbe, JH; VanSchilfgaarde, R; van Schilfgaarde, P.

    Graft failure of alginate-polylysine microencapsulated islets is often interpreted as the consequence of a non-specific foreign body reaction against the microcapsules, initiated by impurities present in crude alginate. The aim of the present study was to investigate if purification of the alginate

  9. Does grafting coronary arteries with only moderate stenosis affect long-term mortality?

    Science.gov (United States)

    Sabik, Joseph F.; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W.; Houghtaling, Penny L.; Blackstone, Eugene H.

    2016-01-01

    Objective Stenting coronary arteries with non–ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. Methods From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Results Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75–0.82; P<.0001). Conclusions Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. PMID:26611750

  10. A Versatile Star PEG Grafting Method for the Generation of Nonfouling and Nonthrombogenic Surfaces

    Directory of Open Access Journals (Sweden)

    Pradeep Kumar Thalla

    2013-01-01

    Full Text Available Polyethylene glycol (PEG grafting has a great potential to create nonfouling and nonthrombogenic surfaces, but present techniques lack versatility and stability. The present work aimed to develop a versatile PEG grafting method applicable to most biomaterial surfaces, by taking advantage of novel primary amine-rich plasma-polymerized coatings. Star-shaped PEG covalent binding was studied using static contact angle, X-ray photoelectron spectroscopy (XPS, and quartz crystal microbalance with dissipation monitoring (QCM-D. Fluorescence and QCM-D both confirmed strong reduction of protein adsorption when compared to plasma-polymerized coatings and pristine poly(ethyleneterephthalate (PET. Moreover, almost no platelet adhesion was observed after 15 min perfusion in whole blood. Altogether, our results suggest that primary amine-rich plasma-polymerized coatings offer a promising stable and versatile method for PEG grafting in order to create nonfouling and nonthrombogenic surfaces and micropatterns.

  11. Surface grafting of poly(L-glutamates). 3. Block copolymerization

    NARCIS (Netherlands)

    Wieringa, RH; Siesling, EA; Werkman, PJ; Vorenkamp, EJ; Schouten, AJ

    2001-01-01

    This paper describes for the first time the synthesis of surface-grafted AB-block copolypeptides, consisting of poly(gamma -benzyl L-glutamate) (PBLG) as the A-block and poly(gamma -methyl L-glutamate) (PMLG) as the B-block. Immobilized primary amine groups of (,gamma -aminopropyl)triethoxysilane

  12. [Rupture of venous bypass graft associated to infection of multiresistant bacteria].

    Science.gov (United States)

    Vidoedo, José C; Toledo, Timmy; Sampaio, Sérgio; Cerqueira, Alfredo; Vilaça, Isabel; Dias, Paulo; Carvalho, Joana; Meira, José; Mansilha, Armando; Paiva, José A; de Albuquerque, Roncon

    2006-01-01

    We report two cases of severe trauma of the upper limb requiring arterial revascularization. A brachio-brachial inverted saphenous bypass graft was done in both cases. Graft rupture attributed to local infection occurred at fourth post-operative week. Pseudomonas aeruginosa was isolated from the surgical wound in the first case and Acinetobacter baumanni in the second. The first case ended up with arm amputation mostly owing to extensive destruction of soft tissue, the patient being discharged home without any other sequel. In the second case the patient was successfully resuscitated after cardiopulmonary arrest, secondary to hemorrhagic shock. He underwent new brachio-brachial venous bypass graft avoiding the contaminated area. Irreversible ischemic signs plus growing overt infection led to arm amputation later on. This patient developed multi-organ failure and died by the fifth post-operative week. Acinetobacter baumannii and Pseudomonas aeruginosa are gram-negative bacilli widely present in hospital environment. Most of them are resistant to commonly used antibiotics. Their association with vascular conduit infections might have dreadful consequences as it happened in these cases.

  13. Aorto-right atrial fistula secondary to rupture of an occluded old saphenous venous graft to right coronary artery.

    Science.gov (United States)

    Balestrini, Carlos Sebastian; Saaibi, José Federico; Ortiz, Santiago Navas

    2014-09-01

    We report a case of an acquired aorta-right atrial fistula, secondary to a ruptured proximal anastomosis of an old saphenous vein graft 12 years after a coronary artery bypass surgery, in a 57 year old patient with multiple cardiovascular risk factors. On admission, he presented with congestive heart failure and on examination a continuous murmur was detected on the right parasternal border. Catheterization showed a fistula from the proximal anastomosis of an occluded right coronary artery saphenous vein graft draining to the right atrium with a large left to right shunt. The fistula was successfully occluded by a percutaneous approach with a Life Tech duct occluder with complete resolution of heart failure. The patient was discharged one week afterwards. After a two-year follow-up, the fistula remained occluded. © 2013 Wiley Periodicals, Inc.

  14. Does the Presence of Primary Circulating Prostate Cells Imply the Presence of Agressive Prostate Cancer with Early Biochemical Failure: a Comparison with the Walz Nomogram.

    Science.gov (United States)

    Murray, Nigel P; Reyes, Eduardo; Orellana, Nelson; Fuentealba, Cynthia; Orellana, Sebastian; Jacob, Omar

    2016-01-01

    To determine the utility of primary circulating prostate cells (CPC) for predicting early biochemical failure after radical prostatectomy for prostate cancer and compare the results with the Walz nomogram. A single centre prospective study of men with prostate cancer treated with radical prostatectomy was conducted between 2004 and 2014. Clinicalpathological details were registered, along with total serum PSA presurgery, Gleason score, extracapsular extension, positive surgical margins, infiltration of lymph nodes, seminal vesicles and pathological stage. Primary circulating prostate cells were obtained using differential gel centrifugation and detected using standard immunocytochemistry with antiPSA. Biochemical failure was defined as a PSA >0.2ng/ml, predictive values were calculated using the Walz nomagram and CPC detection. A total of 285 men participated, of whom 103/285 (36.1%) suffered biochemcial failure; 32/103 (31.1%) within two years of radical prostatectomy. Men with higher Gleason scores, higher pathological stage, infiltration of the surgical margin or prostate capsule and infiltration of seminal vesicles were more likely to undergo biochemical failure. There was a significant increase in the frequency of biochemical failure with increasing number of CPCs detected (p<0.0004 Chi squared for trend) and increasing percent prediction for the Walz nomogram (p<0.0001 Chi squared for trends). The positive predictive value of primary CPC detection, even using a cutoff point of ≥ 4 cells/sample was very low. The detection of primary CPCs in men as a prognostic factor pretreatment fails to identify those at high risk of biochemical failure within two years of curative therapy. This is in keeping with their biological significance, that the majority of them will be eliminated by the primary therapy and thus have no influence on the subsequent clinical history of the patient.

  15. Pretreatment Apparent Diffusion Coefficient of the Primary Lesion Correlates With Local Failure in Head-and-Neck Cancer Treated With Chemoradiotherapy or Radiotherapy

    International Nuclear Information System (INIS)

    Hatakenaka, Masamitsu; Nakamura, Katsumasa; Yabuuchi, Hidetake; Shioyama, Yoshiyuki; Matsuo, Yoshio; Ohnishi, Kayoko; Sunami, Shunya; Kamitani, Takeshi; Setoguchi, Taro; Yoshiura, Takashi; Nakashima, Torahiko; Nishikawa, Kei; Honda, Hiroshi

    2011-01-01

    Purpose: This study was performed to evaluate whether the apparent diffusion coefficient (ADC) of a primary lesion correlates with local failure in primary head-and-neck squamous cell carcinoma (HNSCC) treated with chemoradiotherapy or radiotherapy. Methods and Materials: We retrospectively studied 38 patients with primary HNSCC (12 oropharynx, 20 hypopharynx, 4 larynx, 2 oral cavity) treated with chemoradiotherapy or radiotherapy with radiation dose to gross tumor volume equal to or over 60 Gy and who underwent pretreatment magnetic resonance imaging, including diffusion-weighted imaging. Ten patients developed local failure during follow-up periods of 2.0 to 9.3 months, and the remaining 28 showed local control during follow-up periods of 10.5 to 31.7 months. The variables that could affect local failure (age, tumor volume, ADC, T stage, N stage, dose, treatment method, tumor location, and overall treatment time) were analyzed using logistic regression analyses for all 38 patients and for 17 patients with Stage T3 or T4 disease. Results: In univariate logistic analysis for all 38 cases, tumor volume, ADC, T stage, and treatment method showed significant (p < 0.05) associations with local failure. In multivariate analysis, ADC and T stage revealed significance (p < 0.01). In univariate logistic analysis for the 17 patients with Stage T3 or T4 disease, ADC and dose showed significant (p < 0.01) associations with local failure. In multivariate analysis, ADC alone showed significance (p < 0.05). Conclusions: The results suggest that pretreatment ADC, along with T stage, is a potential indicator of local failure in HNSCC treated with chemoradiotherapy or radiotherapy.

  16. Hypothermic machine perfusion reduces delayed graft function and improves one-year graft survival of kidneys from expanded criteria donors: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Baoping Jiao

    Full Text Available BACKGROUND: Expanded criteria donors (ECDs are currently accepted as potential sources to increase the donor pool and to provide more chances of kidney transplantation for elderly recipients who would not survive long waiting periods. Hypothermic machine perfusion (HMP is designed to mitigate the deleterious effects of simple cold storage (CS on the quality of preserved organs, particularly when the donor is in a marginal status. METHODS: We compared the transplant outcomes in patients receiving ECD kidneys with either HMP or CS graft preservation. Articles from the MEDLINE, EMBASE and Cochrane Library databases were searched and all studies reporting outcomes from HMP versus CS methods of kidney preservation were included in this meta-analysis. The parameters analyzed included the incidence of delayed graft function (DGF, primary non-function (PNF and one-year graft and patient survival. RESULTS: A total of seven studies qualified for the review, involving 2374 and 8716 kidney grafts with HMP or CS preservation respectively, all from ECD donors. The incidence of delayed graft function (DGF was significantly reduced with an odd ratio(OR of 0.59 (95% CI 0.54-0.66, P<0.001 and one-year graft survival was significantly improved with an OR of 1.12 (95% CI 1.03-1.21, P = 0.005 in HMP preservation compared to CS. However, there was no difference in the incidence of PNF (OR 0.54, 95% CI 0.21-1.40, P = 0.20, and one-year patient survival (OR 0.98, 95% CI 0.94-1.02, P = 0.36 between HMP and CS preservation. CONCLUSIONS: HMP was associated with a reduced incidence of DGF and an with increased one-year graft survival, but it was not associated with the incidence of PNF and one-year patient survival.

  17. [The application of delayed skin grafting combined traction in severe joint cicatricial contracture].

    Science.gov (United States)

    Xu, Zihan; Zhang, Zhenxin; Wang, Benfeng; Sun, Yaowen; Guo, Yadong; Gao, Wenjie; Qin, Gaoping

    2014-11-01

    To investigate the effect of delayed skin grafting combined traction in severe joint cicatricial contracture. At the first stage, the joint cicatricial contracture was released completely with protection of vessels, nerves and tendons. The wound was covered with allogenetic skin or biomaterials. After skin traction for 7-14 days, the joint could reach the extension position. Then the skin graft was performed on the wound. 25 cases were treated from Mar. 2000 to May. 2013. Primary healing was achieved at the second stage in all the cases. The skin graft had a satisfactory color and elasticity. Joint function was normal. All the patients were followed up for 3 months to 11 years with no hypertrophic scar and contraction relapse, except for one case who didn' t have enough active exercise on shoulder joint. Delayed skin grafting combined traction can effectively increase the skin graft survival rate and improve the joint function recovery.

  18. Sustained Thromboresistant Bioactivity with Reduced Intimal Hyperplasia of Heparin-Bonded Polytetrafluoroethylene Propaten Graft in a Chronic Canine Femoral Artery Bypass Model.

    Science.gov (United States)

    Freeman, John; Chen, Aaron; Weinberg, Roy J; Okada, Tamuru; Chen, Changyi; Lin, Peter H

    2018-05-01

    Bypass graft thrombosis remains a significant mode of failure in prosthetic graft revascularization. The purpose of this investigation was to evaluate the long-term thromboresistant effect of heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft using Carmeda BioActive Surface technology in a canine model. Bilateral femorofemoral artery bypass grafts with ePTFE grafts were performed in 25 adult grayhound dogs. In each animal, a heparin-bonded ePTFE graft (Propaten, WL Gore) was placed on one side, whereas a control nonheparin graft was placed on the contralateral side. The graft patency was assessed at 1, 6, 12, 18, and 24 months (n = 5 per group) following the bypass. Heparin bioactivity of the graft material was analyzed. The effect of intimal hyperplasia was also assessed. All bypass grafts were patent at 1 month. Significantly greater patency rates were noted in the Propaten group compared to the control group at 12, 18, and 24 months, which were 84%, 80%, and 80% vs. 55%, 35%, and 20%, respectively (P  0.05). Heparin-bonded ePTFE graft provides a thromboresistant surface and reduced anastomotic intimal hyperplasia at 2 years. The stable heparin bioactivity of the Propaten graft confers an advantage in long-term graft patency. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  19. Autograft reconstructions for bone defects in primary total knee replacement in severe varus knees

    Directory of Open Access Journals (Sweden)

    Yatinder Kharbanda

    2014-01-01

    Full Text Available Background: Large posteromedial defects encountered in severe varus knees during primary total knee arthroplasty can be treated by cementoplasty, structural bone grafts or metallic wedges. The option is selected depending upon the size of the defect. We studied the outcome of autograft (structural and impaction bone grafting reconstruction of medial tibial bone defects encountered during primary total knee replacement in severe varus knees. Materials and Methods: Out of 675 primary varus knees operated, bone defects in proximal tibia were encountered in 54 knees. Posteromedial defects involving 25-40% of the tibial condyle cut surface and measuring more than 5 mm in depth were grafted using a structural graft obtained from cut distal femur or proximal tibia in 48 knees. For larger, peripheral uncontained vertical defects in six cases, measuring >25 mm in depth and involving >40% cut surface of proximal tibial condyle, impaction bone grafting with a mesh support was used. Results: Bone grafts incorporated in 54 knees in 6 months. There was no graft collapse or stress fractures, loosening or nonunion. The average followup period was 7.8 years (range 5-10 years. We observed an average postoperative increase in the Knee Society Score from 40 to 90 points. There was improvement in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC scores in terms of pain, stiffness and physical function during activities of daily living. Conclusion: Bone grafting for defects in primary total knee is justified as it is biological, available then and is cost effective besides preserving bone stock for future revisions. Structural grafts should be used in defects >5 mm deep and involving 25-40% of the cut proximal tibial condyle surface. For larger peripheral vertical defects, impaction bone grafting contained in a mesh should be done.

  20. Antimicrobial-impregnated dressing combined with negative-pressure wound therapy increases split-thickness skin graft engraftment: a simple effective technique.

    Science.gov (United States)

    Wu, Cheng-Chun; Chew, Khong-Yik; Chen, Chien-Chang; Kuo, Yur-Ren

    2015-01-01

    Immobilization and adequate surface contact to wounds are critical for skin graft take. Techniques such as the tie-over dressing, cotton bolster, and vacuum-assisted closure are used to address this, but each has its limitations. This study is designed to assess the effect of antimicrobial-impregnated dressing (AMD) combined with negative-pressure wound therapy (NPWT) on skin graft survival. Retrospective case-control study : Patients with chronic or contaminated wounds treated with split-thickness skin graft. A broad spectrum of wounds was included, from causes such as trauma, burns, chronic diabetic ulcers, and infection. Antimicrobial-impregnated dressing, which contains 0.2% polyhexamethylene biguanide, with NPWT MAIN OUTCOME MEASURE:: Success of skin graft : In the AMD group, all skin grafts achieved 100% take without secondary intervention. No infection or graft failure was observed in any patients, and no complications, such as hematoma or seroma formation, were noted, although in the control group partial loss of skin grafts was noted in 3 patients. Infection and inadequate immobilization were thought to be the main reasons. There were no hematoma or seroma formations in the control group. Use of an AMD dressing with NPWT after split-thickness skin grafting can be an effective method to ensure good graft to wound contact and enhances skin graft take in chronic and contaminated wounds.

  1. Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

    Directory of Open Access Journals (Sweden)

    Jung Dug Yang

    2016-09-01

    Full Text Available BackgroundSkin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute.MethodsThis prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A, and RapiGraft and split-thickness skin grafting were used on the other side (group B. All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS, a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months.ResultsThe skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082. Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all. However, the groups did not differ significantly in pliability (P=0.155.ConclusionsThe present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

  2. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  3. Chloroanthraquinone as a grafted probe molecule to investigate grafting yield on carbon powder

    International Nuclear Information System (INIS)

    Le Comte, Annaïg; Brousse, Thierry; Bélanger, Daniel

    2016-01-01

    Spontaneous grafting of chloroanthraquinone (ClAQ) groups on Black Pearls carbon by reduction of the corresponding in-situ generated diazonium cations was successfully achieved. The presence of an halogen atom on the quinone molecule allowed the use of different spectroscopic characterization techniques to determine the accurate quinone content of the modified carbon. Electrochemical characterization highlighted that the presence of chlorine atom on the grafted molecule did not affect the electrochemical response or the grafting reaction efficiency. The amount of ClAQ molecules at the carbon surface after grafting was determined by cyclic voltammetry, together with thermogravimetric analysis coupled mass spectroscopy, X-ray photoelectron spectroscopy and elemental analysis. The ClAQ mass loadings estimated from the four techniques are in very good agreement and confirm that the grafted moieties are all electrochemically active and accessible. Finally, the grafting of quinone-type molecule using the reduction of diazonium cations does not affect the electroactivity of the grafted groups and cyclic voltammetry can be considered as a reliable technique to evaluate the mass loading of grafted quinone groups on porous carbon. Thus ClAQ can be used as a grafted probe molecule to investigate grafting yield on carbon powder, and this approach can be extended to functionalized electrodes used in an increasing number of electrochemical energy storage devices.

  4. Influence of Diabetes on Long-Term Coronary Artery Bypass Graft Patency.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Rajeswaran, Jeevanantham; Riaz, Haris; Bakaeen, Faisal G; Lincoff, A Michael; Sabik, Joseph F

    2017-08-01

    Nearly 50% of patients undergoing coronary artery bypass grafting have diabetes. However, little is known about the influence of diabetes on long-term patency of bypass grafts. Because patients with diabetes have more severe coronary artery stenosis, we hypothesized that graft patency is worse in patients with than without diabetes. This study sought to examine the influence of diabetes on long-term patency of bypass grafts. From 1972 to 2011, 57,961 patients underwent primary isolated coronary artery bypass grafting. Of these, 1,372 pharmacologically treated patients with diabetes and 10,147 patients without diabetes had 15,887 postoperative angiograms; stenosis was quantified for 7,903 internal thoracic artery (ITA) grafts and 20,066 saphenous vein grafts. Status of graft patency across time was analyzed by longitudinal nonlinear mixed-effects modeling. ITA graft patency was stable over time and similar in patients with and without diabetes: at 1, 5, 10, and 20 years, 97%, 97%, 96%, and 96% in patients with diabetes, and 96%, 96%, 95%, and 93% in patients without diabetes, respectively (early p = 0.20; late p = 0.30). In contrast, saphenous vein graft patency declined over time and similarly in patients with and without diabetes: at 1, 5, 10, and 20 years, 78%, 70%, 57%, and 42% in patients with diabetes, and 82%, 72%, 58%, and 41% in patients without diabetes, respectively (early p < 0.002; late p = 0.60). After adjusting for patient characteristics, diabetes was associated with higher early patency of ITA grafts (odds ratio: 0.63; 95% confidence limits: 0.43 to 0.91; p = 0.013), but late patency of ITA grafts was similar in patients with and without diabetes (p = 0.80). Early and late patency of saphenous vein grafts were similar in patients with and without diabetes (early p = 0.90; late p = 0.80). Contrary to our hypothesis, diabetes did not influence long-term patency of bypass grafts. Use of ITA grafts should be maximized in patients

  5. [The appropriate use of pharmacological treatment in patients with chronic heart failure. A perspective from Primary Care].

    Science.gov (United States)

    Naveiro-Rilo, J C; Diez-Juárez, D; Flores-Zurutuza, M L; Molina Mazo, R; Alberte Pérez, C; Arias Cobos, V

    2013-01-01

    The appropriate use of pharmacological treatment according to the indications in Clinical Guidelines reduces morbidity and mortality in patients with chronic heart failure (CHF). There are numerous studies regarding this in the hospital environment, but there are few studies done in Primary Care. The objective of this study is to evaluate the degree of compliance by Primary Care doctors to the Clinical Guidelines of the European Society of Cardiology in patients with CHF. A descriptive, observational study on the use of indication-prescription drugs was conducted. Primary Care teams of the Leon Health Area (9 urban and 19 rural). The study population included patients with a diagnosis of New York Heart Association (NYHA) Grade II-IV chronic heart failure, from a register of 2047 with chronic heart failure patients treated by 97 Primary Care doctors. A proportional representative random sample of 474 patients from the urban and rural areas was studied. Adherence to the drugs recommended in the Clinical Guidelines was evaluated using two indicators; one overall, and another for drugs with a higher level of evidence (A1: angiotensin converting enzyme inhibitors-angiotensin II receptor antagonists [ACE-I/ARA-II], β-blockers [BB] and spironolactone). A total of 456 patients were studied, with a mean age of 78.4 years, and 53.1% females. Arterial hypertension (AHT) and ischaemic heart disease were present in 64.7% of patients. The mean comorbidity rate, excluding CHF, was 2.9. Around 40% were diagnosed a NYHA Grade 11-1V. The overall compliance rate (diuretics, ACE-I/ARA-II, β-blockers, spironolactone, digoxin, and oral anticoagulants) and rate of adherence to evidence-based ones was 55.2% and 44.6%, respectively. There was low compliance by 39.5%, and only 12.9% of patients showed perfect compliance with the drugs with a higher level of evidence, while to be less than 70 years-old, a history of ischaemia, AHT, and a hospital admission, were variables associated with

  6. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  7. Endo-luminal grafting for treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Fu Weiguo; Wang Yuqi; Chen Fuzhen; Ye Jianrong; Wang Jianhua; Yan Zhiping; Cheng Jiemin

    2000-01-01

    Objective: To evaluate the preliminary clinical results of endovascular procedures for abdominal aortic aneurysms (AAA) in a prospective study. Methods: Six patients (average age 70 years, range 56 to 78) with infrarenal AAA were enrolled in Shanghai Zhongshan hospital from February 1998 to February 1999. Computed tomography and angiography were done in every patient for measurement of the length, diameter, and angulation of the proximal and distal AAA necks, aneurysm sac, and common and external iliac arteries. The average diameter of the aneurysm was 6.3 cm (range 4.6 cm to 8.0 cm). The mean proximal neck diameter was 2.0 cm (range 1.8 cm to 2.2 cm) and proximal neck length was 3.0 cm (range 2.5 cm to 3.5 cm). All patients were treated with the endo-luminal grafting for exclusion of AAA. Results: Two tubular and 4 bifurcated endo-grafts were used. All endo-graft procedures were completed successfully. One patient died of renal failure 72 hours after the procedure because of the prolonged operative time and excessive contrast medium. Aortography after the procedure showed the AAA were excluded by endo-graft and no endo-leak in the proximal or distal connections was detected. The patients could take meal and were ambulatory on the first and second postoperative day, respectively. Clinical success (aneurysm exclusion with no death or endo-leak) at 30 days was 83.3%. In the 24 months follow-up in 5 cases, no migration, endo-leak, and increasing aneurysm size were detected with spiral CT or color Duplex ultrasound. Conclusion: Based on initial results and a short term mean follow-up period of 24 months, the endovascular treatment of AAA with stent-graft system is feasible and safe. Further study will be required to observe the long term result in the exclusion of AAA

  8. Pre-transplant course and risk of kidney transplant failure in IgA nephropathy patients.

    Science.gov (United States)

    Bjørneklett, Rune; Vikse, Bjørn Egil; Smerud, Hilde Kloster; Bostad, Leif; Leivestad, Torbjørn; Hartmann, Anders; Iversen, Bjarne M

    2011-01-01

    There is lack of knowledge to what degree clinical/morphological presentation and course of IgA nephropathy (IgAN) prior to end-stage renal disease are risk factors for graft loss after kidney transplantation. Patients with IgAN between 1988 and 2006 (registered in the Norwegian Kidney Biopsy Registry) who later received a kidney transplant (registered in the Norwegian Renal Registry) were included. The cohort was followed up regarding death-censored graft loss throughout 2008. Graft survival with a rapid progressive (RP) vs. a slow progressive (SP) course of pre-Tx IgAN (annual GFR > or <30 mL/min/1.73 m(2) ) was studied. Among 106 included patients, there were 14 graft losses giving a graft loss rate of 1.9/100 patient years. Follow-up until the first kidney transplant was 6.9 ± 4.4 (range 0.1-19) yr. Patients with pre-Tx RP had a higher graft loss rate compared with SP patients (6.3 vs.1.3/100 patient years, p < 0.001). Graft loss rate with living-related donor (LRD) was similar to unrelated donor (UD) grafts. Most RP patients had received LRD grafts, and in SP patients, graft survival with LRD grafts was better than UD grafts (0.3 vs.2.1/100 patient years, p = 0.055). A rapid pre-transplant course is a strong risk factor for transplant failure in patients with IgAN. © 2011 John Wiley & Sons A/S.

  9. Does site of buccal mucosa graft for bulbar urethra stricture affect outcome? A comparative analysis of ventral, dorso-lateral and dorsal buccal mucosa graft augmentation urethroplasty.

    Science.gov (United States)

    Pathak, Hemant R; Jain, Tarunkumar Prakash; Bhujbal, Sachin A; Meshram, Kunal R; Gadekar, Chetan; Parab, Sandesh

    2017-09-01

    To compare long- term outcomes of buccal mucosa graft (BMG) augmentation urethroplasty for long segment bulbar urethral strictures done by placing the graft ventrally, dorso-laterally and dorsally. We conducted a single institution retrospective study on 112 who underwent BMG augmentation urethroplasty for non-traumatic bulbar urethral strictures between January 2005 to December 2014. The cases were divided into three groups based on the site of placement of BMG graft i.e. (a) Ventral (n=44), (b) Dorso-lateral (n=48) and (c) Dorsal (n=20). Follow-up period was from one year to five years. Patients with failed outcomes underwent urethroscopy or retrograde urethrogram to note the site of recurrence of stricture. Out of 112 cases 91 (81%) were successful and 21 (19%) failed. The success rates for ventral, dorso-lateral and dorsal BMG augmentation procedures were 89%, 79% and 70%, respectively (p=0.18). Among 21 failed cases, 12 cases (57%) had stricture at proximal anastomotic site, 4 cases (19%) at graft and 5 cases (24%) at distal anastomotic site (p=0.01). The overall success rate for BMG augmentation urethroplasty is equal for all techniques. Ventral onlay urethroplasty provides better exposure of proximal anastomotic site thus it is associated with minimum proximal anastomotic site recurrence rates. Patients with extensive spongiofibrosis and long segment strictures had higher rates of failure.

  10. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Dialysis Arteriovenous Fistula Failure and Angioplasty: Intimal Hyperplasia and Other Causes of Access Failure

    Science.gov (United States)

    Duque, Juan C.; Tabbara, Marwan; Martinez, Laisel; Cardona, Jose; Vazquez-Padron, Roberto I; Salman, Loay H

    2016-01-01

    Arteriovenous fistula (AVF) is the preferred hemodialysis access type because it has better patency rates and fewer complications than other access types. However, primary failure remains a common problem impeding AVF maturation and adding to patients’ morbidity and mortality. Juxta-anastomotic (or inflow) stenosis is the most common reason leading to primary failure, and percutaneous transluminal angioplasty (PTA) continues to be the gold standard treatment with excellent success rates. Intimal hyperplasia (IH) has been traditionally blamed as the main pathophysiologic culprit, but new evidence raises doubts regarding the contribution of IH alone to primary failure. We report a 64-year-old man with a two-stage brachio-basilic AVF that was complicated by failure four months after creation. Angiogram showed multiple juxta-anastomotic and mid-fistula stenotic lesions. PTA was successful in assisting maturation and subsequently cannulating AVF for hemodialysis treatment. We failed to identify the underlying cause of stenosis as biopsy specimens from fistula tissue obtained at the time of transposition revealed no occlusive IH. This case emphasizes the need for additional research on factors contributing to AVF failure besides IH, and highlights the need for more therapeutic options to reduce AVF failure rate. PMID:28084215

  12. Advanced composites structural concepts and materials technologies for primary aircraft structures: Structural response and failure analysis

    Science.gov (United States)

    Dorris, William J.; Hairr, John W.; Huang, Jui-Tien; Ingram, J. Edward; Shah, Bharat M.

    1992-01-01

    Non-linear analysis methods were adapted and incorporated in a finite element based DIAL code. These methods are necessary to evaluate the global response of a stiffened structure under combined in-plane and out-of-plane loading. These methods include the Arc Length method and target point analysis procedure. A new interface material model was implemented that can model elastic-plastic behavior of the bond adhesive. Direct application of this method is in skin/stiffener interface failure assessment. Addition of the AML (angle minus longitudinal or load) failure procedure and Hasin's failure criteria provides added capability in the failure predictions. Interactive Stiffened Panel Analysis modules were developed as interactive pre-and post-processors. Each module provides the means of performing self-initiated finite elements based analysis of primary structures such as a flat or curved stiffened panel; a corrugated flat sandwich panel; and a curved geodesic fuselage panel. This module brings finite element analysis into the design of composite structures without the requirement for the user to know much about the techniques and procedures needed to actually perform a finite element analysis from scratch. An interactive finite element code was developed to predict bolted joint strength considering material and geometrical non-linearity. The developed method conducts an ultimate strength failure analysis using a set of material degradation models.

  13. Graft union formation in artichoke grafting onto wild and cultivated cardoon: an anatomical study.

    Science.gov (United States)

    Trinchera, Alessandra; Pandozy, Gianmarco; Rinaldi, Simona; Crinò, Paola; Temperini, Olindo; Rea, Elvira

    2013-12-15

    In order to develop a non-chemical method such as grafting effective against well-known artichoke soil borne diseases, an anatomical study of union formation in artichoke grafted onto selected wild and cultivated cardoon rootstocks, both resistant to Verticillium wilt, was performed. The cardoon accessions Belgio (cultivated cardoon) and Sardo (wild cardoon) were selected as rootstocks for grafting combinations with the artichoke cv. Romolo. Grafting experiments were carried out in the autumn and spring. The anatomical investigation of grafting union formation was conducted by scanning electron microscopy (SEM) on the grafting portions at the 3rd, 6th, 10th, 12th day after grafting. For the autumn experiment only, SEM analysis was also performed at 30 d after grafting. A high affinity between artichoke scion and cardoon rootstocks was observed, with some genotype differences in healing time between the two bionts. SEM images of scion/rootstock longitudinal sections revealed the appearance of many interconnecting structures between the two grafting components just 3d after grafting, followed by a vascular rearrangement and a callus development during graft union formation. De novo formation of many plasmodesmata between scion and rootstock confirmed their high compatibility, particularly in the globe artichoke/wild cardoon combination. Moreover, the duration of the early-stage grafting process could be influenced not only by the scion/rootstock compatibility, but also by the seasonal conditions, being favored by lower temperatures and a reduced light/dark photoperiod. Copyright © 2013 Elsevier GmbH. All rights reserved.

  14. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  15. PREDICTION AND PREVENTION OF LIVER FAILURE AFTER MAJOR LIVER PRIMARY AND METASTATIC TUMORS RESECTION

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2016-01-01

    Full Text Available Abstract Purpose of the study. Improvement of results of treatment in patients with primary and metastatic liver cancer by decreasing the risk of post-resection liver failure on the basis of the evaluation of the functional reserves of the liver.Materials and Methods. The study included two independent samples of patients operated about primary or metastatic lesions of the liver at the Department of abdominal Oncology, P. A. Hertsen MORI. The first group included 53 patients who carried out 13C-breath test metallimovie and dynamic scintigraphy of the liver in the preoperative stage in addition to the standard algorithm of examination. Patients of the 2nd group (n=35 had a standard clinical and laboratory examination, the patients were not performed the preoperative evaluation of the functional reserve of the liver, the incidences of total bilirubin, albumin and prothrombin time did not reveal a reduction of liver function. Post-resection liver failure have been established on the basis of the 50/50 criterion in the evaluation on day 5 after surgery.Results. Analysis of operating characteristics of the functional tests showed the absolute methacin breath test sensitivity (SE≥100%, high specificity (SP≥67% of scintigraphy of the liver and the negative predictive value of outcome (VP≥100% at complex use of two diagnostic methods. The incidence of PROPS in the study group was significantly 2 times higher in the control group –15,1% and 26.8%, respectively (p<0.001.Conclusion. The combination of preoperative dynamic scintigraphy of the liver with carrying out 13C-breath methacin test allows you to conduct a comprehensive evaluation of the liver functional reserve and can significantly improve preoperative evaluation and postoperative results of anatomic resection in patients with primary and metastatic liver lesions.

  16. Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft.

    Science.gov (United States)

    Rhee, Sung Min; Oh, Joo Han

    2017-12-01

    Few comparative studies have reported on the use of biologic grafts for irreparable massive rotator cuff tears. The purpose of this study was to assess the results of arthroscopic bridging graft in irreparable massive rotator cuff tears using an autogenic long head of biceps tendon (LHBT) or an allogenic dermal patch (ADP). We retrospectively reviewed 24 patients treated using the LHBT (group I) and eight patients with complete rupture of the LHBT treated using an ADP (group II) since 2011. Preoperative Goutallier's fatty degeneration, range of motion (ROM), visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed and healing failure was evaluated at 1 year after surgery by ultrasonography or magnetic resonance imaging. The mean fatty degeneration in groups I and II was 3.9 and 3.6 for the supraspinatus ( p = 0.288), 2.7 and 2.9 for the infraspinatus ( p = 0.685), 0.9 and 1.3 for the subscapularis ( p = 0.314), and 1.3 and 3.0 for the teres minor ( p = 0.005), respectively. Subscapularis tears were found in 8 patients (33.3%) in group I and in 7 patients (87.5%) in group II ( p = 0.023). Mean ROMs and functional scores improved significantly in group I (forward flexion: 121.7° to 153.3°, p = 0.010; external rotation: 32.7° to 52.7°, p = 0.001; external rotation at 90°: 63.3° to 74.5°, p = 0.031; internal rotation: T10.5 to T9.3, p = 0.045; VAS: 7.0 to 1.1, p rotator cuff tears, especially in patients with severe fatty degeneration in the teres minor or combined biceps and subscapularis tears.

  17. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  18. Development of the mechanical properties of engineered skin substitutes after grafting to full-thickness wounds.

    Science.gov (United States)

    Sander, Edward A; Lynch, Kaari A; Boyce, Steven T

    2014-05-01

    Engineered skin substitutes (ESSs) have been reported to close full-thickness burn wounds but are subject to loss from mechanical shear due to their deficiencies in tensile strength and elasticity. Hypothetically, if the mechanical properties of ESS matched those of native skin, losses due to shear or fracture could be reduced. To consider modifications of the composition of ESS to improve homology with native skin, biomechanical analyses of the current composition of ESS were performed. ESSs consist of a degradable biopolymer scaffold of type I collagen and chondroitin-sulfate (CGS) that is populated sequentially with cultured human dermal fibroblasts (hF) and epidermal keratinocytes (hK). In the current study, the hydrated biopolymer scaffold (CGS), the scaffold populated with hF dermal skin substitute (DSS), or the complete ESS were evaluated mechanically for linear stiffness (N/mm), ultimate tensile load at failure (N), maximum extension at failure (mm), and energy absorbed up to the point of failure (N-mm). These biomechanical end points were also used to evaluate ESS at six weeks after grafting to full-thickness skin wounds in athymic mice and compared to murine autograft or excised murine skin. The data showed statistically significant differences (p clinical morbidity from graft loss.

  19. Grafting of model primary amine compounds to cellulose nanowhiskers through periodate oxidation

    Science.gov (United States)

    Rajalaxmi Dash; Thomas Elder; Arthur Ragauskas

    2012-01-01

    This study demonstrates regioselective oxidation of cellulose nanowhiskers using 2.80–10.02 mmols of sodium periodate per 5 g of whiskers followed by grafting with methyl and butyl amines through a Schiff base reaction to obtain their amine derivatives in 80–90 % yield. We found a corresponding increase in carbonyl content (0.06–0.14 mmols/g) of the dialdehyde...

  20. Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez, Patrícia, E-mail: pbermude@clinic.ub.es [Clinic Hospital of Barcelona, Vascular and Interventional Radiology Unit, Diagnostic Imaging Institute (Spain); Fontseré, Nestor, E-mail: fontsere@clinic.ub.es [Clinic Hospital of Barcelona, Vascular Access Unit, Nephrologic and Urologic Diseases Clinical Institute (Spain); Mestres, Gaspar, E-mail: gmestres@clinic.ub.es [Clinic Hospital of Barcelona, Cardiovascular Diseases Institute (Spain); García-Gámez, Andres, E-mail: garciagam@clinic.ub.es; Barrufet, Marta, E-mail: barrufet@clinic.ub.es; Burrel, Marta, E-mail: mburrel@clinic.ub.es; Gilabert, Rosa, E-mail: gilabert@clinic.ub.es; Gómez, Fernando, E-mail: fegomez@clinic.ub.es; Macho, Juan, E-mail: jmmacho@clinic.ub.es [Clinic Hospital of Barcelona, Vascular and Interventional Radiology Unit, Diagnostic Imaging Institute (Spain)

    2017-02-15

    PurposeTo evaluate the efficacy and safety of the hydrodynamic thrombectomy catheter (AngioJet DVX) in the salvage of thrombosed hemodialysis vascular grafts.Materials and MethodsA retrospective study was designed, including all patients with occluded arteriovenous grafts treated with the AngioJet system between 2007 and 2014 in our institution. Outcomes included technical success, clinical success, complications, and primary and secondary patencies. Procedural success was defined as angiographic confirmation of flow restoration, the presence of a pulsatile thrill along the graft, and successful resumption of at least one hemodialysis session. Primary and secondary patencies after first AVG thrombectomy were calculated with Kaplan–Meier curves. Cox regression was used to determine prognostic factors of primary patency after every thrombectomy episode.ResultsA total of 149 thrombectomies were performed in 68 grafts. After thrombectomy, endovascular treatment of one or more stenosis was performed in all cases. Technical success was 93% and clinical success was 86%. Complications occurred in 7 thrombectomies, most of them were minor except for one anastomosis rupture requiring surgery. Primary and secondary patencies were 52, 41, and 23 and 76, 68, and 57% at 3, 6 and 12 months, respectively. Independent prognostic factors of poor patency after every thrombectomy episode were the presence of residual thrombus (OR 1.831, P = 0.008) and time from last thrombosis (less than 1 month; and OR 7.116, P < 0.001).ConclusionPercutaneous mechanical thrombectomy with AngioJet is a safe technique with a high-clinical success rate. The presence of residual thrombus after thrombectomy and early re-occlusions are related to poorer results.

  1. Robotic Ureteroplasty with Buccal Mucosa Graft for the Management of Complex Ureteral Strictures.

    Science.gov (United States)

    Lee, Ziho; Waldorf, Benjamin T; Cho, Eric Y; Liu, Jeffrey C; Metro, Michael J; Eun, Daniel D

    2017-12-01

    Surgical management of proximal and mid ureteral strictures that are not amenable to primary excision and anastomosis is challenging. Although a buccal mucosa graft is commonly used during substitution urethroplasty, its use in substitution ureteroplasty is limited. We describe our technique of robotic ureteroplasty with a buccal mucosa graft to manage complex ureteral strictures and we report our outcomes. We retrospectively reviewed the records of 12 patients who underwent robotic ureteroplasty with a buccal mucosa graft between September 2014 and June 2016. The indication for the procedure was a proximal or mid ureteral stricture not amenable to primary excision and anastomosis. The primary outcomes were clinical success, absent symptoms on ureteral pathology and radiological success, defined as absent ureteral obstruction on retrograde pyelography, renal scan and/or computerized tomography. Four of the 12 patients (33.3%) had a ureteropelvic junction stricture, 4 (33.3%) had a proximal stricture and 4 (33.3%) had a mid ureteral stricture. Eight of the 12 patients (66.7%) had previously undergone failed ureteral reconstruction. Median stricture length was 3 cm (range 2 to 5). Median operative time was 217 minutes (range 136 to 344) and mean estimated blood loss was 100 ml (range 50 to 200). Median length of stay was 1 day (range 1 to 6). At a median followup of 13 months (range 4 to 30) 10 of the 12 cases (83.3%) were clinically and radiologically successful. Robotic ureteroplasty with a buccal mucosa graft is associated with low inherent morbidity. It is an effective way to manage complex proximal and mid ureteral strictures. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    Science.gov (United States)

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  3. Postoperative irradiation after reconstructive surgery: comparative study of radiosensitivity between free-skin grafts and skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Kaneda, T.; Oka, T.; Torii, S.; Sakuma, S.

    1984-01-01

    Radiation effects after reconstructive surgery (free-skin grafts and skin flaps) were studied in the rat, and the optimum time for irradiation was determined. The radiosensitivity of both free-skin grafts and skin flaps showed the same trend depending on time of irradiation after operation. The grafts or flaps irradiated in the hypervascular stage showed severe reactions to irradiation, whereas those irradiated in the hypovascular stage showed milder reactions in gross and microangiographic observation. Vascular damage should be given primary consideration when deciding the proper time for irradiation after reconstructive surgery. In general, free-skin grafts showed more severe reactions than skin flaps, especially in the grafts irradiated in the early stage after operation. The experimental results of this study cannot be readily transferred to a clinical setting, but they suggest that postoperative irradiation could be begun 3 to 4 weeks after operation with respect to graft or flap survival, and the results of the clinical cases almost coincide with these experimental results

  4. [Role of outpatient heart failure clinics and primary care physicians in the tailored follow-up of heart failure patients].

    Science.gov (United States)

    De Maria, Renata; Misuraca, Gianfranco; Milli, Massimo; Filippi, Alessandro

    2010-05-01

    Continuity of care is pivotal to appropriately manage patients affected by heart failure (HF). HF is a chronic disease with frequent exacerbations that requires long-term care at different complexity levels. The lack of adequate communication between hospital cardiologists and primary care physicians (PCPs) is the main pitfall in continuity of care for HF patients. To overcome this problem, all dedicated outpatient HF clinics should organize together with PCPs in the community educational and auditing initiatives, based on locally derived performance measures to assess the appropriateness and effectiveness of integrated care pathways. The primary task of PCPs is to follow up stable HF patients and focus assessment on patient empowerment, adjustment of drug therapy, assessment of clinical stability and the early identification of worsening signs and symptoms. The progress of information technology should help in achieving adequate communication between hospital professionals and PCPs; outpatient clinical records should in any case comply with qualitative standards of discharge summaries for all patients taken in charge by PCPs. Systematic assessment of shared care between hospital cardiologists and PCPs will be a main objective of the outpatient HF clinic network in the near future.

  5. Modification of polyetherurethane for biomedical application by radiation-induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1985-01-01

    Radiation grafting of monomers onto suitable trunk polymers is a useful tool for tailoring new polymers for special purposes. This technique has been used in the past for the development of biocompatible materials, e.g., by grafting hydrogels onto mechanically stable polymers. In this first part of our work, the radiation grafting of hydrophilic or reactive monomers onto a polyetherurethane film using the pre-swelling technique is described. Following this technique the trunk polymer was swollen in the monomer before irradiation. As monomers 2-hydroxyethyl methacrylate (HEMA), 2,3-epoxypropyl methacrylate (GMA), 2,3-dihydroxypropyl methacrylate (GOMA), and acrylamide (AAm) were used. The kinetics of the grafting reactions were examined, and the distribution of the graft component inside the trunk polymer was investigated by means of infrared (IR) spectroscopy. Surface-grafted as well as bulk- and surface-grafted products could be obtained. The mechanical behavior of the grafted films--especially in the water-swollen state--was examined and compared with that of the pure trunk polymer. In nearly all cases it was found that the tensile strength sigma B and the elongation at break epsilon R decreases as the grafting yield increases. Modification of GMA- and AAm-grafted films via chemical reactions was performed to create new functional groups of biomedical interest. In this manner a diol structure, a carboxylic acid structure, and a sulfonic acid group could be introduced in the grafted polymer. The water uptake of such modified films is increased markedly when compared with that of the unmodified samples

  6. Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Buergelova, M.

    2009-01-01

    This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 μmol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 μmol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m 2 . The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.

  7. Functional recovery after facial nerve cable grafting in a rodent model.

    NARCIS (Netherlands)

    Hohman, M.H.; Kleiss, I.J.; Knox, C.J.; Weinberg, J.S.; Heaton, J.T.; Hadlock, T.A.

    2014-01-01

    IMPORTANCE: Cable grafting is widely considered to be the preferred alternative to primary repair of the injured facial nerve; however, quantitative comparison of the 2 techniques has not been previously undertaken in a rodent model. OBJECTIVE: To establish functional recovery parameters after

  8. Midterm Experience of Ipsilateral Axillary-Axillary Arteriovenous Loop Graft as Tertiary Access for Haemodialysis

    Directory of Open Access Journals (Sweden)

    J. P. Hunter

    2014-01-01

    Full Text Available Objectives. To present a series of ipsilateral axillary artery to axillary vein loop arm grafts as an alternative vascular access procedure for haemodialysis in patients with difficult access. Design. Retrospective case series. Methods. Patients who underwent an axillary loop arteriovenous graft from September 2009 to September 2012 were included. Preoperative venous imaging to exclude central venous stenosis and to image arm/axillary veins was performed. A cuffed PTFE graft was anastomosed to the distal axillary artery and axillary vein and looped on the arm. Results. 25 procedures were performed on 22 patients. Median age was 51 years, with 9 males and 13 females. Median number of previous access procedures was 3 (range 0–7. Median followup was 16.4 months (range 1–35. At 3 months and 1 year, the primary and secondary patency rates were 70% and 72% and 36% and 37%, respectively. There were 11 radiological interventions in 6 grafts including 5 angioplasties and 6 thrombectomies. There were 19 surgical procedures in 10 grafts, including thrombectomy, revision, repair for bleeding, and excision. Conclusions. Our series demonstrates that the axillary loop arm graft yields acceptable early patency rates in a complex group of patients but to maintain graft patency required high rates of surgical and radiological intervention, in particular graft thrombectomy.

  9. [Value of preserved saphenous vein graft for the creation of access ports in hemodialyzed patients: report of 309 cases].

    Science.gov (United States)

    Schneider, Marc; Barrou, Benoît; Cluzel, Philippe; Hamani, Aziz; Bitker, Marc-Olivier; Richard, François

    2003-09-01

    Biological grafts are rarely used for the creation of vascular access, despite their many advantages. Our group prefers to use distal vascular accesses with interposition of a biological graft when direct access cannot be achieved. The objective of this study was to determine the long-term patency and the complication rate of a series of 309 vascular access procedures using a preserved saphenous (PS) vein homograft. 410 (27%) of the 1,500 vascular access procedures performed by our group required the use of a graft, including 376 PS vein homografts (25%). This retrospective study comprised complete data collection for 309 arteriovenous fistulas (AVF) using preserved saphenous (PS) vein graft in the forearm performed in 267 patients between 1985 and 2000. Primary patency was defined as the interval between creation of the vascular access and the first complication requiring surgical or radiological correction; secondary patency was defined as the interval between creation and loss of the graft, with or without revision of the fistula. Survival rates were calculated according to the Kaplan-Meier method. Inter-group comparison was performed by the Logrank test and analysis of variance was performed by logistic regression. Primary patency rates were 77%, 40% and 27% at 1,2 and 5 years, respectively. Secondary patency rates were 79% and 47% at 1 year and 5 years, respectively. The thrombosis rate was 42%. Two episodes of thrombosis occurred in 25% of grafts and 3 episodes were observed in 10% of cases. Infection rates were 1.9% postoperatively and 5% after dialysis, respectively. An aneurysm occurred on 10% of grafts. The operator's experience (RR = 1.58; p creation of vascular accesses with similar patency rates to those of prosthetic grafts. Vein grafts present a number of advantages, particularly a greater ease of use facilitating distal implantation of the graft and a low infection rate.

  10. Risk score for predicting long-term mortality after coronary artery bypass graft surgery.

    Science.gov (United States)

    Wu, Chuntao; Camacho, Fabian T; Wechsler, Andrew S; Lahey, Stephen; Culliford, Alfred T; Jordan, Desmond; Gold, Jeffrey P; Higgins, Robert S D; Smith, Craig R; Hannan, Edward L

    2012-05-22

    No simplified bedside risk scores have been created to predict long-term mortality after coronary artery bypass graft surgery. The New York State Cardiac Surgery Reporting System was used to identify 8597 patients who underwent isolated coronary artery bypass graft surgery in July through December 2000. The National Death Index was used to ascertain patients' vital statuses through December 31, 2007. A Cox proportional hazards model was fit to predict death after CABG surgery using preprocedural risk factors. Then, points were assigned to significant predictors of death on the basis of the values of their regression coefficients. For each possible point total, the predicted risks of death at years 1, 3, 5, and 7 were calculated. It was found that the 7-year mortality rate was 24.2 in the study population. Significant predictors of death included age, body mass index, ejection fraction, unstable hemodynamic state or shock, left main coronary artery disease, cerebrovascular disease, peripheral arterial disease, congestive heart failure, malignant ventricular arrhythmia, chronic obstructive pulmonary disease, diabetes mellitus, renal failure, and history of open heart surgery. The points assigned to these risk factors ranged from 1 to 7; possible point totals for each patient ranged from 0 to 28. The observed and predicted risks of death at years 1, 3, 5, and 7 across patient groups stratified by point totals were highly correlated. The simplified risk score accurately predicted the risk of mortality after coronary artery bypass graft surgery and can be used for informed consent and as an aid in determining treatment choice.

  11. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  12. Full-thickness skin graft vs. synthetic mesh in the repair of giant incisional hernia: a randomized controlled multicenter study.

    Science.gov (United States)

    Clay, L; Stark, B; Gunnarsson, U; Strigård, K

    2018-04-01

    Repair of large incisional hernias includes the implantation of a synthetic mesh, but this may lead to pain, stiffness, infection and enterocutaneous fistulae. Autologous full-thickness skin graft as on-lay reinforcement has been tested in eight high-risk patients in a proof-of-concept study, with satisfactory results. In this multicenter randomized study, the use of skin graft was compared to synthetic mesh in giant ventral hernia repair. Non-smoking patients with a ventral hernia > 10 cm wide were randomized to repair using an on-lay autologous full-thickness skin graft or a synthetic mesh. The primary endpoint was surgical site complications during the first 3 months. A secondary endpoint was patient comfort. Fifty-three patients were included. Clinical evaluation was performed at a 3-month follow-up appointment. There were fewer patients in the skin graft group reporting discomfort: 3 (13%) vs. 12 (43%) (p = 0.016). Skin graft patients had less pain and a better general improvement. No difference was seen regarding seroma; 13 (54%) vs. 13 (46%), or subcutaneous wound infection; 5 (20%) vs. 7 (25%). One recurrence appeared in each group. Three patients in the skin graft group and two in the synthetic mesh group were admitted to the intensive care unit. No difference was seen for the primary endpoint short-term surgical complication. Full-thickness skin graft appears to be a reliable material for ventral hernia repair producing no more complications than when using synthetic mesh. Patients repaired with a skin graft have less subjective abdominal wall symptoms.

  13. Determining the degree of grafting for poly (vinylidene fluoride) graft-copolymers using fluorine elemental analysis

    International Nuclear Information System (INIS)

    Yu Yang; Zhang Bowu; Yang Xuanxuan; Deng Bo; Li Linfan; Yu Ming; Li Jingye

    2011-01-01

    Acrylic acid (AAc) and styrene (St) were grafted onto poly (vinylidene fluoride) (PVDF) powder or membrane samples by pre-irradiation graft copolymerization. The grafted chains were proved by FT-IR spectroscopy analysis. The degree of grafting (DG) of the grafted PVDF was determined by fluorine elemental analysis (FEA) method, and was compared with the DGs determined by weighing method, acid-base back titration method and quantitative FT-IR method. The results show that the FEA method is accurate, convenient and universal, especially for the grafted polymer powders. (authors)

  14. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  15. Inlay buccal mucosal graft for reoperative posterior urethroplasty.

    Science.gov (United States)

    Tang, Shou-Hung; Kao, Chien-Chang; Wu, Seng-Tang; Meng, En; Cha, Tai-Lung

    2012-04-01

    Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007-2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o'clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12-15 ml/seconds in all cases for a follow-up period of 18-30 months. The recurrence rate was 50% (2/4). Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases. Copyright © 2012. Published by Elsevier B.V.

  16. Inlay buccal mucosal graft for reoperative posterior urethroplasty

    Directory of Open Access Journals (Sweden)

    Shou-Hung Tang

    2012-04-01

    Full Text Available Posterior urethral distraction injury following major pelvic trauma is a surgical challenge. Although rarely seen, cases of failure after formal urethral reconstruction are even more problematic. We adapted the concept of augmented free buccal mucosal grafts, which have been successful in anterior urethroplasty, for repairing the posterior urethra in these rare cases with the aim of reducing the likelihood of penile chordee postoperatively. During 2007–2009, four patients were candidates for the proposed procedure because they had received formal transperineal urethral reconstruction but were unable to urinate through the urethra. The urethra was approached transperineally and opened in the midline, rather than divided. Buccal mucosal grafts of an appropriate size were placed in the created urethral groove from 4- to 8 o’clock in the lithotomy view. After the procedure, the urethral catheter was kept for 3 weeks. All patients voided through the urethra after the procedure. The maximal postoperative urinary flow rates were between 12–15 ml/seconds in all cases for a follow-up period of 18–30 months. The recurrence rate was 50% (2/4. Recurrent strictures were minor, and they showed a web-like stricture ring near the suture line. Restricture within 6 months of surgery responded well to endoscopic internal urethrotomy plus dilatations. In conclusion, without further compromising urethral length, reoperative posterior urethroplasty with the inlay grafting technique can be considered in selective cases.

  17. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    Science.gov (United States)

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  18. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  19. Determinant Factors in Graft Rejection Using Cox Regression, among the Recipients of Second Renal Transplant in Imam Khomeini Hospital in Urmia, 1988-2000

    Directory of Open Access Journals (Sweden)

    Rahim Tahmasebi

    2010-09-01

    Full Text Available Background: The objective of this study was to evaluate graft survival among the recipients of second renal transplant in Imam Khomeini centre hospital in Urmia. Methods: The study population consisted of 50 patients receiving renal grafts for the second time between 1988 and 2008 in Imam Khomeini centre hospital in Urmia. Two survival outcomes, first and second graft survival, were analyzed. Graft survival was defined from date of transplant until its rejection. For the purpose of graft survival analysis, graft failure was defined as return to dialysis, and death due to the functioning graft. Data were collected through individual patient questionnaires. Demographic and clinical factors, transfusion history, type of immunosuppressive drugs, levels of serum creatinine, triglyceride, cholesterol, and LDL at 3 and 6 months after transplantation were collected. Cox-proportional hazard model and Kaplan-Meier were used to data analysis. Results: First graft survival at 1, 2, 3, and 5 years was 74%, 66%, 53%, and 41%, respectively. Second graft survival at 1, 2, 3, and 5 years was 81%, 74%, 70%, and 61%, respectively. Causes of graft loss in first renal transplantation were 6% sever acute graft rejection, 12% acute graft rejection and 82% chronic graft rejection. In the multivariate analysis, only serum creatinine, blood pressure, and immunosuppressive drugs predicted first graft loss and serum creatinine, immunosuppressive drugs, and related donor family predicted second graft rejection. Conclusion: The serum creatinine and immunosuppressive drugs including cyclosporine, cellcept, and prednisolone are the most influential factors on graft survival.

  20. Primary care-based multifaceted, interdisciplinary medical educational intervention for patients with systolic heart failure: lessons learned from a cluster randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Schellberg Dieter

    2009-08-01

    Full Text Available Abstract Background Chronic (systolic heart failure (CHF is a common and disabling condition. Adherence to evidence-based guidelines in primary care has been shown to improve health outcomes. The aim was to explore the impact of a multidisciplinary educational intervention for general practitioners (GPs (Train the trainer = TTT on patient and performance outcomes. Methods This paper presents the key findings from the trial and discusses the lessons learned during the implementation of the TTT trial. Primary care practices were randomly assigned to the TTT intervention or to the control group. 37 GPs (18 TTT, 19 control were randomised and 168 patients diagnosed with ascertained CHF (91 TTT, 77 control were enrolled. GPs in the intervention group attended four meetings addressing clinical practice guidelines and pharmacotherapy feedback. The primary outcome was patient self-reported quality of life at seven months, using the SF-36 Physical Functioning scale. Secondary outcomes included other SF-36 scales, the Kansas City Cardiomyopathy Questionnaire (KCCQ, total mortality, heart failure hospital admissions, prescribing, depressive disorders (PHQ-9, behavioural change (European Heart Failure Self-Care Behaviour Scale, patient-perceived quality of care (EUROPEP and improvement of heart failure using NT-proBNP-levels. Because recruitment targets were not achieved an exploratory analysis was conducted. Results There was high baseline achievement in both groups for many outcomes. At seven months, there were no significant mean difference between groups for the primary outcome measure (-3.3, 95%CI -9.7 to 3.1, p = 0.30. The only difference in secondary outcomes related to the prescribing of aldosterone antagonists by GPs in the intervention group, with significant between group differences at follow-up (42 vs. 24%, adjusted OR = 4.0, 95%CI 1.2–13; p = 0.02. Conclusion The intervention did not change the primary outcome or most secondary outcomes

  1. Primary care-based multifaceted, interdisciplinary medical educational intervention for patients with systolic heart failure: lessons learned from a cluster randomised controlled trial.

    Science.gov (United States)

    Peters-Klimm, Frank; Campbell, Stephen; Müller-Tasch, Thomas; Schellberg, Dieter; Gelbrich, Goetz; Herzog, Wolfgang; Szecsenyi, Joachim

    2009-08-13

    Chronic (systolic) heart failure (CHF) is a common and disabling condition. Adherence to evidence-based guidelines in primary care has been shown to improve health outcomes. The aim was to explore the impact of a multidisciplinary educational intervention for general practitioners (GPs) (Train the trainer = TTT) on patient and performance outcomes. This paper presents the key findings from the trial and discusses the lessons learned during the implementation of the TTT trial. Primary care practices were randomly assigned to the TTT intervention or to the control group. 37 GPs (18 TTT, 19 control) were randomised and 168 patients diagnosed with ascertained CHF (91 TTT, 77 control) were enrolled. GPs in the intervention group attended four meetings addressing clinical practice guidelines and pharmacotherapy feedback. The primary outcome was patient self-reported quality of life at seven months, using the SF-36 Physical Functioning scale. Secondary outcomes included other SF-36 scales, the Kansas City Cardiomyopathy Questionnaire (KCCQ), total mortality, heart failure hospital admissions, prescribing, depressive disorders (PHQ-9), behavioural change (European Heart Failure Self-Care Behaviour Scale), patient-perceived quality of care (EUROPEP) and improvement of heart failure using NT-proBNP-levels. Because recruitment targets were not achieved an exploratory analysis was conducted. There was high baseline achievement in both groups for many outcomes. At seven months, there were no significant mean difference between groups for the primary outcome measure (-3.3, 95%CI -9.7 to 3.1, p = 0.30). The only difference in secondary outcomes related to the prescribing of aldosterone antagonists by GPs in the intervention group, with significant between group differences at follow-up (42 vs. 24%, adjusted OR = 4.0, 95%CI 1.2-13; p = 0.02). The intervention did not change the primary outcome or most secondary outcomes. Recruitment targets were not achieved and the under

  2. Ovarian Grafts 10 Days after Xenotransplantation: Folliculogenesis and Recovery of Viable Oocytes.

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Almeida Campos-Junior

    Full Text Available Ovarian xenotransplantation is a promising alternative to preserve fertility of oncologic patients. However, several functional aspects of this procedure remained to be addressed. The aim of this study was evaluate the feasibility of xenotransplantation as a strategy to maintain bovine ovarian grafts and produce oocytes. Adult ovarian cortical pieces were xenotransplanted to the dorsal subcutaneous of female NOD-SCID mice (n = 62. Grafts were recovered ten days after xenotransplantation. Host and graft weights; folliculogenesis progression; blood perfusion, relative gene expression and number of macrophage and neutrophil of xenografts; in vitro developmental competence of graft-derived oocytes were evaluated. Folliculogenesis was supported in the grafts, as indicated by the presence of primordial, primary, secondary, antral, and atretic follicles. The xenografts showed a greater volumetric density of atretic follicles and higher hyperemia and number of host-derived macrophage and neutrophil (P<0.05, when compared to non-grafted fragments. There was a higher blood perfusion under the back skin in the transplantation sites of host animals than in control and non-grafted (P<0.01. BAX and PRDX1 genes were up-regulated, while BCL2, FSHR, IGF1R and IGF2R were down-regulated, when compared to the control (P<0.01. Twenty seven oocytes were successfully harvested from grafts, and some of these oocytes were able to give rise to blastocysts after in vitro fertilization. However, cleavage and blastocyst rates of xenograft derived oocytes were lower than in control (P<0.01. Despite showing some functional modifications, the ovarian xenografts were able to support folliculogenesis and produce functional oocytes.

  3. Synthesis of ion exchange membrane by radiation grafting of acrylic acid onto polyethylene

    International Nuclear Information System (INIS)

    Ishigaki, I.; Sugo, T.; Senoo, K.; Takayama, T.; Machi, S.; Okamoto, J.; Okada, T.

    1981-01-01

    Radiation grafting of vinyl monomers onto polymer films has been extensively studied by many workers. In the preirradiation method of grafting a polymer substrate is activated by irradiation (either in the presence or absence of oxygen) and subsequently allowed to react with a monomer. The preirradiation method was utilized in this study to synthesize an ion exchange membrane useful for a battery separator by grafting acrylic acid onto polyethylene film. The battery separator should be chemically and thermally stable, sufficiently durable in electrolyte as well as highly electrically conductive. Membranes made from regenerated cellulose, e.g., cellophane, have long been used as a separator in the batteries with alkaline electrolyte, such as silver oxide primary cell. However, it has poor durability, as short as one year, due to breakdown of the membrane during operation or storing. The acrylic acid-grafted polyethylene film was found to be quite useful for a separator in the alkaline batteries. This membrane has a high electric conductivity and an excellent durability. (author)

  4. Use of Chitosan-PVA Hydrogels with Copper Nanoparticles to Improve the Growth of Grafted Watermelon.

    Science.gov (United States)

    González Gómez, Homero; Ramírez Godina, Francisca; Ortega Ortiz, Hortensia; Benavides Mendoza, Adalberto; Robledo Torres, Valentín; Cabrera De la Fuente, Marcelino

    2017-06-22

    Modern agriculture requires alternative practices that improve crop growth without negatively affecting the environment, as resources such as water and arable land grow scarcer while the human population continues to increase. Grafting is a cultivation technique that allows the plant to be more efficient in its utilization of water and nutrients, while nanoscale material engineering provides the opportunity to use much smaller quantities of consumables compared to conventional systems but with similar or superior effects. On those grounds, we evaluated the effects of chitosan-polyvinyl alcohol hydrogel with absorbed copper nanoparticles (Cs-PVA-nCu) on leaf morphology and plant growth when applied to grafted watermelon cultivar 'Jubilee' plants. Stomatal density (SD), stomatal index (SI), stoma length (SL), and width (SW) were evaluated. The primary stem and root length, the stem diameter, specific leaf area, and fresh and dry weights were also recorded. Our results demonstrate that grafting induces modifications to leaf micromorphology that favorably affect plant growth, with grafted plants showing better vegetative growth in spite of their lower SD and SI values. Application of Cs-PVA-nCu was found to increase stoma width, primary stem length, and root length by 7%, 8% and 14%, respectively. These techniques modestly improve plant development and growth.

  5. Use of Chitosan-PVA Hydrogels with Copper Nanoparticles to Improve the Growth of Grafted Watermelon

    Directory of Open Access Journals (Sweden)

    Homero González Gómez

    2017-06-01

    Full Text Available Modern agriculture requires alternative practices that improve crop growth without negatively affecting the environment, as resources such as water and arable land grow scarcer while the human population continues to increase. Grafting is a cultivation technique that allows the plant to be more efficient in its utilization of water and nutrients, while nanoscale material engineering provides the opportunity to use much smaller quantities of consumables compared to conventional systems but with similar or superior effects. On those grounds, we evaluated the effects of chitosan-polyvinyl alcohol hydrogel with absorbed copper nanoparticles (Cs-PVA-nCu on leaf morphology and plant growth when applied to grafted watermelon cultivar ‘Jubilee’ plants. Stomatal density (SD, stomatal index (SI, stoma length (SL, and width (SW were evaluated. The primary stem and root length, the stem diameter, specific leaf area, and fresh and dry weights were also recorded. Our results demonstrate that grafting induces modifications to leaf micromorphology that favorably affect plant growth, with grafted plants showing better vegetative growth in spite of their lower SD and SI values. Application of Cs-PVA-nCu was found to increase stoma width, primary stem length, and root length by 7%, 8% and 14%, respectively. These techniques modestly improve plant development and growth.

  6. A grafting from approach to graft polystyrene chains at the surface of graphene nanolayers by RAFT polymerization: Various graft densities from hydroxyl groups

    Energy Technology Data Exchange (ETDEWEB)

    Roghani-Mamaqani, Hossein, E-mail: r.mamaghani@sut.ac.ir [Department of Polymer Engineering, Sahand University of Technology, PO Box 51335-1996, Tabriz (Iran, Islamic Republic of); Khezri, Khezrollah [School of Chemistry, University College of Science, University of Tehran, PO Box 14155-6455, Tehran (Iran, Islamic Republic of)

    2016-01-01

    Graphical abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. - Highlights: • A RAFT agent grafted GO was used in grafting from RAFT polymerization of styrene. • The efficiency of RAFT agent attachment at the surface of GO is 41.12% for high density sample. • Polystyrene molecular weight is decreased by the addition of graphene content and also graft density of RAFT agent. - Abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. Grafting of APTES and RA was approved by Fourier transform infrared spectroscopy, X-ray photo electron spectroscopy, and Raman spectroscopy. Expansion of graphene interlayer by oxidation and functionalization processes was evaluated by X-ray diffraction. Conversion values of styrene were calculated using gas chromatography. Molecular weight and PDI values of attached polystyrene (PS) chains were studied by size exclusion chromatography. Thermogravimetric analysis was also used to investigate the degradation temperatures, char contents, and graft contents of modifiers and PS chains. GOHRH and GOHRL reach to char content of 55.3 and 45.2% at 600 °C, which shows that weight ratio of modifier (APTES and RA moieties) is 15.3 and 5.2%, respectively. Scanning and transmission electron microscopies show that

  7. Local bone graft harvesting and volumes in posterolateral lumbar fusion: a technical report.

    Science.gov (United States)

    Carragee, Eugene J; Comer, Garet C; Smith, Micah W

    2011-06-01

    In lumbar surgery, local bone graft is often harvested and used in posterolateral fusion procedures. The volume of local bone graft available for posterolateral fusion has not been determined in North American patients. Some authors have described this as minimal, but others have suggested the volume was sufficient to be reliably used as a stand-alone bone graft substitute for single-level fusion. To describe the technique used and determine the volume of local bone graft available in a cohort of patients undergoing single-level primary posterolateral fusion by the authors harvesting technique. Technical description and cohort report. Consecutive patients undergoing lumbar posterolateral fusion with or without instrumentation for degenerative processes. Local bone graft volume. Consecutive patients undergoing lumbar posterolateral fusion with or without instrumentation for degenerative processes of were studied. Local bone graft was harvested by a standard method in each patient and the volume measured by a standard procedure. Twenty-five patients were studied, and of these 11 (44%) had a previous decompression. The mean volume of local bone graft harvested was measured to be 25 cc (range, 12-36 cc). Local bone graft was augmented by iliac crest bone in six of 25 patients (24%) if the posterolateral fusion bed was not well packed with local bone alone. There was a trend to greater local bone graft volumes in men and in patients without previous decompression. Large volumes of local bone can be harvested during posterolateral lumbar fusion surgery. Even in patients with previous decompression the volume harvested is similar to that reported harvested from the posterior iliac crest for single-level fusion. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  9. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  10. Pain following double-bundle anterior cruciate ligament reconstruction: Correlation with morphological graft findings and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Lin, Y.-C.; Mhuircheartaigh, J.N.; Cheung, Y.-C.; Juan, Y.-H.; Chiu, C.-H.; Yeh, W.-L.; Wu, J.S.

    2014-01-01

    Aim: To determine the relationship between knee pain following anterior cruciate ligament (ACL) graft placement with morphological graft findings and dynamic contrast enhancement as assessed at MRI. Material and methods: Following institutional review board approval, 37 consecutive patients with double-bundle ACL reconstruction were enrolled. Thirteen patients had pain and 24 were asymptomatic. Imaging was performed using a 1.5 T MRI machine an average of 7.6 months after surgery. Graft-related (increase signal intensity, abnormal orientation, discontinuity, cystic degeneration, anterior translation of lateral tibia, arthrofibrosis), and non-graft related causes of knee pain (meniscal tear, cartilage injury, loose bodies, and synovitis) were evaluated. During dynamic contrast enhancement analysis, peak enhancement (ePeak) was calculated by placing a region of interest at the osteoligamentous interface of each bundle. Student's t-test was used for continuous variables analysis and chi-square or Fisher's exact test was used for categorical variables analysis. Results: There was no difference between symptomatic and asymptomatic patients regarding morphological graft-related or non-graft-related causes of knee pain. For dynamic contrast enhancement analysis, symptomatic patients had significantly lower ePeak values than asymptomatic patients in the anteromedial (p = 0.008) and posterolateral (p = 0.001) bundles or when using the higher ePeak value in either bundle (p = 0.003). Conclusion: Morphological ACL graft findings as assessed at MRI could not be used to distinguish between symptomatic and asymptomatic patients. However, lower ePeak values had a significant association with knee pain. This may indicate poor neovascularization of the graft, potentially leading to graft failure. - Highlights: • Morphologic graft findings of MRI are poorly associated with knee pain. • Lower contrast enhancement values are significantly associated with knee pain

  11. Prediction factors for failure to seek treatment following traumatic dental injuries to primary teeth

    Directory of Open Access Journals (Sweden)

    Ramon Targino Firmino

    2014-06-01

    Full Text Available The objective of this study was to evaluate prediction factors for failure to seek treatment following a traumatic dental injury (TDI to primary teeth among preschool children in the city of Campina Grande, Brazil. A cross-sectional study was carried out involving 277 children 3 to 5 years of age, with TDI, enrolled in public and private preschools. Parents filled out a form addressing demographic data and whether or not they had sought treatment. Clinical examinations were performed by three dentists who had undergone a calibration exercise (Kappa: 0.85 to 0.90 for the evaluation of TDI. Bivariate and multivariate Poisson regression models were constructed (α = 5%. Enamel fracture was the most prevalent type of TDI (48.7% and the upper central incisors were the most affected teeth (88.4%. The frequency of seeking dental treatment was low (9.7%. The following variables were associated with failure to seek treatment following TDI: a household income greater than one minimum wage (PR = 1.170; 95%CI 1.018-1.341, parents/caregivers’ perception of a child’s oral health as poor (PR = 1.100; 95%CI 1.026-1.176, and the non-perception of TDI by parents/caregivers (PR = 1.250; 95%CI 1.142-1.360. In the present study, the frequency of seeking treatment following TDI was low, and parents/caregivers with a higher income, a poor perception of their child’s oral health and a lack of awareness regarding the trauma were more likely to fail to seek treatment following TDI to primary teeth.

  12. Primary Gleason pattern in biopsy Gleason score 7 is predictive of adverse histopathological features and biochemical failure following radical prostatectomy

    DEFF Research Database (Denmark)

    Berg, Kasper Drimer; Røder, Martin Andreas; Brasso, Klaus

    2014-01-01

    +3. No difference in age, PSA, percentage of biopsies with cancer, clinical tumour stage or volume on transrectal ultrasonography was found. Primary Gleason pattern 4 was associated with worse pathological stage (p = 0.049). On multivariate analysis, primary Gleason pattern 4 (p ... (p analysis, Gleason score 3+4 had a significantly lower biochemical failure rate compared with Gleason score 4+3 (p = 0.0035). PSA (p 4 (p = 0.001) and percentage of biopsies...

  13. A facile metal-free "grafting-from" route from acrylamide-based substrate toward complex macromolecular combs

    KAUST Repository

    Zhao, Junpeng

    2013-01-01

    High-molecular-weight poly(N,N-dimethylacrylamide-co-acrylamide) was used as a model functional substrate to investigate phosphazene base (t-BuP 4)-promoted metal-free anionic graft polymerization utilizing primary amide moieties as initiating sites. The (co)polymerization of epoxides was proven to be effective, leading to macromolecular combs with side chains being single- or double-graft homopolymer, block copolymer and statistical copolymer. © 2013 The Royal Society of Chemistry.

  14. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  15. Microsurgical reconstruction of large nerve defects using autologous nerve grafts.

    Science.gov (United States)

    Daoutis, N K; Gerostathopoulos, N E; Efstathopoulos, D G; Misitizis, D P; Bouchlis, G N; Anagnostou, S K

    1994-01-01

    Between 1986 and 1993, 643 patients with peripheral nerve trauma were treated in our clinic. Primary neurorraphy was performed in 431 of these patients and nerve grafting in 212 patients. We present the functional results after nerve grafting in 93 patients with large nerve defects who were followed for more than 2 years. Evaluation of function was based on the Medical Research Council (MRC) classification for motor and sensory recovery. Factors affecting functional outcome, such as age of the patient, denervation time, length of the defect, and level of the injury were noted. Good results according to the MRC classification were obtained in the majority of cases, although function remained less than that of the uninjured side.

  16. Case report: paradoxical ventricular septal motion in the setting of primary right ventricular myocardial failure.

    Science.gov (United States)

    Maslow, Andrew; Schwartz, Carl; Mahmood, Feroze; Singh, Arun; Heerdt, Paul M

    2009-07-01

    In this report, a case of right ventricular (RV) failure, hemodynamic instability, and systemic organ failure is described to highlight how paradoxical ventricular systolic septal motion (PVSM), or a rightward systolic displacement of the interventricular septum, may contribute to RV ejection. Multiple inotropic medications and vasopressors were administered to treat right heart failure and systemic hypotension in a patient following combined aortic and mitral valve replacement. In the early postoperative period, echocardiographic evaluation revealed adequate left ventricular systolic function, akinesis of the RV myocardial tissues, and PVSM. In the presence of PVSM, RV fractional area of contraction was > or =35% despite akinesis of the primary RV myocardial walls. The PVSM appeared to contribute toward RV ejection. As a result, the need for multiple inotropes was re-evaluated, in considering that end-organ dysfunction was the result of systemic hypotension and prolonged vasopressor administration. After discontinuation of phosphodiesterase inhibitors, native vascular tone returned and the need for vasopressors declined. This was followed by recovery of systemic organ function. Echocardiographic re-evaluation two years later, revealed persistent akinesis of the RV myocardial tissues and PVSM, the latter appearing to contribute toward RV ejection. This case highlights the importance of left to RV interactions, and how PVSM may mediate these hemodynamic interactions.

  17. Determination of the distribution of graft yields following a radiation-induced graft copolymerization

    International Nuclear Information System (INIS)

    Schipschack, K.; Wagner, H.; Sawtschenko, L.

    1976-01-01

    In the radiation-induced graft copolymerization on solid initial polymers a distribution of graft yields takes place along the cross-sections of samples. Methods for determining this distribution, which are described in the literature, are reviewed. In our own investigations boards made of ethylene-vinyl acetate copolymers and grafted with vinyl chloride were used. Distributions of the grafted component obtained by infrared analysis of microtome cuts parallel to the surface are partly rather inhomogeneous, and are interpreted as dependent on the experimental parameters. (author)

  18. Survival of Dental Implants Placed in Grafted and Nongrafted Bone: A Retrospective Study in a University Setting.

    Science.gov (United States)

    Tran, Duong T; Gay, Isabel C; Diaz-Rodriguez, Janice; Parthasarathy, Kavitha; Weltman, Robin; Friedman, Lawrence

    2016-01-01

    To compare dental implant survival rates when placed in native bone and grafted sites. Additionally, risk factors associated with dental implant loss were identified. This study was based on the hypothesis that bone grafting has no effect on implant survival rates. A retrospective chart review was conducted for patients receiving dental implants at the University of Texas, School of Dentistry from 1985 to 2012. Exclusion criteria included patients with genetic diseases, radiation and chemotherapy, or an age less than 18 years. To avoid misclassification bias, implants were excluded if bone grafts were only done at the same time of placement. Data on age, sex, tobacco use, diabetes, osteoporosis, anatomical location of the implant, implant length and width, bone graft, and professional maintenance were collected for analysis. A total of 1,222 patients with 2,729 implants were included. The cumulative survival rates at 5 and 10 years were 92% and 87% for implants placed in native bone and 90% and 79% for implants placed in grafted bone, respectively. The results from multivariate analysis (Cox regression) indicated no significant difference in survival between the two groups; having maintenance therapy after implant placement reduced the failure rate by 80% (P dental implant survival rate when implants were placed in native bone or bone-grafted sites. Smoking and lack of professional maintenance were significantly related to increased implant loss.

  19. Study on grafting glycidyl methacrylate onto HDPE membranes by pre-irradiation graft copolymerization

    International Nuclear Information System (INIS)

    Tong Long; Zu Jianhua; Liu Xinwen; Sun Guisheng; Yu Chunhui

    2006-01-01

    Glycidyl methacrylate (GMA) was grafted onto HDPE membranes by pre-irradiation method with 1.8 MeV E-beam and a kind of membranes having reactive epoxy groups was successfully synthesized. Effects of monomer concentration, reaction temperature and time and irradiation dose on the grafting yield were studied. Composition, thermo-property and surface morphology of the grafted membranes were studied by FTIR, DSC and Tapping-mode AFM, respectively. The FTIR measurements proved the synthesized copolymer is HDPE-g-GMA. The DSC results indicated the grafted HDPE's melting temperature (T m ) and heat of fusion (ΔH f ( HDPE) ) which was reduced with increasing grafting yield. The AFM images indicated that surface of the HDPE-g-GMA membranes was rougher than the virgin HDPE. (authors)

  20. Hamstrings tendon graft preparation for anterior cruciate ligament reconstruction using the WhipKnotTM soft tissue cinch technique.

    Directory of Open Access Journals (Sweden)

    Amin Masoumiganjgah

    2012-04-01

    Full Text Available BackgroundAppropriate graft tension and secure graft incorporation inbone tunnels are essential for successful anterior cruciateligament (ACL reconstruction using hamstrings tendonautografts. The WhipKnot™ soft tissue cinch, introduced bySmith and Nephew in 2004, is an alternative option to thecommonly used whipstitch technique during preparation ofthe hamstring autograft in ACL reconstruction.AimsTo investigate the effectiveness of the WhipKnot™ softtissue cinch and technique during the preparation of thetendon graft for ACL reconstruction.MethodA total of 33 ACL reconstruction operations performedbetween February 2011 and December 2011 were includedin this study. These were performed by a single seniorsurgeon who used the Whipknot™ technique for thepreparation of each graft. Four were used for eachoperation; two for each end of the harvested hamstringstendons, including semitendinosus and gracilis tendonsrespectively.ResultsIn total, 132 WhipKnots were used during the kneeoperations. Use of the WhipKnot™ technique resulted insuccessful graft preparations, tensioning and effective graftplacement in the tibial and femoral tunnels in almost allinstances. Only one case of WhipKnot™ failure (slippagewas recorded.ConclusionThese results indicate that the Whipknot™ technique is asafe, reliable and practical option for the preparation of thehamstrings autografts.

  1. Biosynthetic graft failure to replace infected infrainguinal bypass as developing infection due to Morganella morganii leading to disrupture of the anastomosis. Case report

    Directory of Open Access Journals (Sweden)

    Gladiol Zenunaj

    Full Text Available Introduction: Biosynthetic prosthesis has become the trend to carry out arterial reconstruction in infected sites since considered to be resistant to infection. Late graft occlusion is the only complication reported in literature so far. We report a case of biosynthetic graft infection which led to early detachment of the femoral anastomosis of a femoral-popliteal above-knee bypass. Material: A 76-year-old man developed groin infection 3 months later after performing an ePTFE femoral-popliteal above-knee bypass for critical limb ischemia. He was re-admitted for groin infection involving the vascular structures. Explantation of the existing bypass and its replacement with a biosynthetic graft (omniflow II was performed. Detachment of the proximal anastomosis occurred 6 days later leading to groin haematoma. Consequently, retroperitoneal access was performed for clamping the external iliac artery so as to control haemorrhage followed by explantation of the biosynthetic graft. An external iliac-popliteal above-knee bypass was tailored in order to save the limb and it was performed using a transobturator approach avoiding the infected site. In both cases bacterial cultures resulted positive for Morganella Morganii. The groin wound was treated separately with negative pressure medication healing definitively within 20 days and after 3-month follow-up the bypass was still patent. Conclusion: This is the first report of biosynthetic graft infection used for infrainguinal reconstruction leading to haemorrhage due to anastomosis disrupture. Using an extra-anatomical access for providing blood inflow to the leg avoiding the infected site and treating safely the groin wound with VAC therapy revealed to be a valid approach. Keywords: Infrainguinal bypass, Graft infection, Biosynthetic material, Graft occlusion, Negative pressure medication, Morganella morgani

  2. Effect of Ticagrelor Plus Aspirin, Ticagrelor Alone, or Aspirin Alone on Saphenous Vein Graft Patency 1 Year After Coronary Artery Bypass Grafting: A Randomized Clinical Trial.

    Science.gov (United States)

    Zhao, Qiang; Zhu, Yunpeng; Xu, Zhiyun; Cheng, Zhaoyun; Mei, Ju; Chen, Xin; Wang, Xiaowei

    2018-04-24

    The effect of ticagrelor with or without aspirin on saphenous vein graft patency in patients undergoing coronary artery bypass grafting (CABG) is unknown. To compare the effect of ticagrelor + aspirin or ticagrelor alone vs aspirin alone on saphenous vein graft patency 1 year after CABG. Randomized, multicenter, open-label, clinical trial among 6 tertiary hospitals in China. Eligible patients were aged 18 to 80 years with indications for elective CABG. Patients requiring urgent revascularization, concomitant cardiac surgery, dual antiplatelet or vitamin K antagonist therapy post-CABG, and who were at risk of serious bleeding were excluded. From July 2014 until November 2015, 1256 patients were identified and 500 were enrolled. Follow-up was completed in January 2017. Patients were randomized (1:1:1) to start ticagrelor (90 mg twice daily) + aspirin (100 mg once daily) (n = 168), ticagrelor (90 mg twice daily) (n = 166), or aspirin (100 mg once daily) (n = 166) within 24 hours post-CABG. Neither patients nor treating physicians were blinded to allocation. Primary outcome was saphenous vein graft patency 1 year after CABG (FitzGibbon grade A) adjudicated independently by a committee blinded to allocation. Saphenous vein graft patency was assessed by multislice computed tomographic angiography or coronary angiography. Among 500 randomized patients (mean age, 63.6 years; women, 91 [18.2%]), 461 (92.2%) completed the trial. Saphenous vein graft patency rates 1 year post-CABG were 88.7% (432 of 487 vein grafts) with ticagrelor + aspirin; 82.8% (404 of 488 vein grafts) with ticagrelor alone; and 76.5% (371 of 485 vein grafts) with aspirin alone. The difference between ticagrelor + aspirin vs aspirin alone was statistically significant (12.2% [95% CI, 5.2% to 19.2%]; P aspirin alone was not statistically significant (6.3% [95% CI, -1.1% to 13.7%]; P = .10). Five major bleeding episodes occurred during 1 year of follow-up (3 with

  3. Long-term use and follow-up of autologous and homologous cartilage graft in rhinoplasty

    Directory of Open Access Journals (Sweden)

    Ghasemali Khorasani

    2016-05-01

    Full Text Available Background: Cartilage grafting is used in rhinoplasty and reconstructive surgeries. Autologous rib and nasal septum cartilage (auto graft is the preferred source of graft material in rhinoplasty, however, homologous cartilage (allograft has been extensively used to correct the nasal framework in nasal deformities. Autologous cartilage graft usage is restricted with complication of operation and limiting availability of tissue for extensive deformities. Alternatively, preserved costal cartilage allograft represents a readily available and easily contoured material. The current study was a formal systematic review of complications associated with autologous versus homologous cartilage grafting in rhinoplasty patients. Methods: In this cohort retrospective study, a total of 124 patients undergone primary or revision rhinoplasty using homologous or autologus grafts with postoperative follow-up ranging from 6 to 60 months were studied. The types of grafts and complications related to the grafts were evaluated. This included evaluation for warping, infection, resorption, mobility and fracture. Results: The total complications related to the cartilage grafts were 7 cases, which included 1 warped in auto graft group, three cases of graft displacement (two in allograft group and one in auto graft group and three fractures in allograft group. No infection and resorption was recorded. Complication rate (confidence interval 0.95 in autologous and homologous group were 1.25(0.4-3.88 and 2.08(0.78-5.55 in 1000 months follow up. There was no statistically significant difference between autologous and homologous group complications. Onset of complication in autologous and homologous group were 51.23(49.27-53.19 and 58.7(54.51-62.91 month respectively (P=0.81. Conclusion: The allograft cartilage has the advantage of avoiding donor-site scar. Moreover, it provides the same benefits as autologous costal cartilage with comparable complication rate. Therefore, it

  4. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  5. Lycopene and flesh colour differences in grafted and non-grafted watermelon

    OpenAIRE

    Fekete D.; Stéger-Máté M.; Bőhm V.; Balázs G.; Kappel N.

    2015-01-01

    The experiment was carried out in three regions in Hungary (Jászszentandrás, Cece, Újkígyós) in 2013 to determine the fruit quality of grafted watermelon (Citrullus lanatus Thunb.). The “RX 467” seedless watermelon variety was grafted on two commercial rootstocks “FR STRONG” [Lagenaria siceraria (Mol.) Standl.] and “RS 841” (Cucurbita maxima Duchesne × Cucurbita moschata Duchesne). The lycopene and flesh colours are important quality characteristics even of the selfrooted and grafted watermel...

  6. HLA antibodies and soluble CD30 are associated with poor renal graft outcome: updated results of a single-center cross-sectional study.

    Science.gov (United States)

    Langan, Leanne L; D'Orsogna, Lloyd; Park, Lawrence P; Hughes, Tiffany L; Irish, Ashley; Luxton, Grant; Witt, Campbell S; Christiansen, Frank T

    2006-01-01

    In a previous study, we have shown that HLA class II antibodies and a high soluble CD30 (sCD30) measured at least 1 year post-transplant predict subsequent graft failure. We have now updated the results of this same cohort of 208 patients 15 months later. HLA-specific antibodies (class I and class II) were detected by ELISA LAT-M and Luminex LabScreen assays. Data on graft outcome was collected with a median follow-up of 4.7 years. By Kaplan-Meier analysis, class II antibody was again associated with a poorer outcome, with an estimated 6-year graft survival of 67% and 71% when detected by ELISA and Luminex, respectively, compared with 92% for those without class II antibody (p soluble CD30 level of > or = 100 U/ml was also associated with a poorer estimated 6-year graft survival (p = 0.02). HLA antibodies and high sCD30 (> or = 100 U/ml) had an additive effect such that those with both high sCD30 and class II antibodies had a hazard ratio for subsequent graft failure of 18.1 (p = 0.0008) and 8.6 (p = 0.007) when detected by ELISA and Luminex, respectively. These data show that detection of HLA class II antibodies and serum sCD30 measured at least 1 year post-transplant continues to predict a subsequent outcome up to 6 years after the initial measurement; they also show that such measures provide important information that may allow for modification of ongoing therapy.

  7. A new grafting technique for tympanoplasty: tympanoplasty with a boomerang-shaped chondroperichondrial graft (TwBSCPG).

    Science.gov (United States)

    Dündar, Rıza; Soy, Fatih Kemal; Kulduk, Erkan; Muluk, Nuray Bayar; Cingi, Cemal

    2014-10-01

    The aim of this study was to introduce a new grafting technique in tympanoplasty that involves use of a boomerang-shaped chondroperichondrial graft (BSCPG). The anatomical and functional results were evaluated. A new tympanoplasty with boomerang-shaped chondroperichondrial graft (TwBSCPG) technique was used in 99 chronic otitis media patients with central or marginal perforation of the tympanic membrane and a normal middle ear mucosa. All 99 patients received chondroperichondrial cartilage grafts with a boomerang-shaped cartilage island left at the anterior and inferior parts. Postoperative follow-ups were conducted at months 1, 6, and 12. Preoperative and postoperative audiological examinations were performed and air-bone gaps were calculated according to the pure-tone averages (PTAs) of the patients. In the preoperative period, most (83.8%) air-bone gaps were ≥ 16 dB; after operating using the TwBSCPG technique, the air-bone gaps decreased to 0-10 dB in most patients (77.8%). In the TwBSCPG patients, the mean preoperative air-bone gap was 22.02 ± 6.74 dB SPL. Postoperatively, the mean postoperative air-bone gap was 8.70 ± 5.74 dB SPL. The TwBSCPG technique therefore decreased the postoperative air-bone gap compared to that preoperatively (p = 0.000, z = -8.645). At the 1-month follow-up, there were six graft perforations and one graft retraction. At the 6-month follow-up, there were nine graft perforations and three graft retractions. At 12 months, there were seven graft perforations and four graft retractions. During the first year after the boomerang tympanoplasty surgery, graft lateralization was not detected in any patient. Retractions were grade 1 according to the Sade classification and were localized to the postero-superior quadrant of the tympanic membrane. The TwBSCPG technique has benefits with respect to postoperative anatomical and audiological results. It prevents perforation of the tympanic membrane at the anterior quadrant and avoids graft

  8. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  9. Impact of bone graft harvesting techniques on bone formation and graft resorption

    DEFF Research Database (Denmark)

    Saulacic, Nikola; Bosshardt, Dieter D; Jensen, Simon S

    2015-01-01

    BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone fo......: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption.......BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone...... formation and graft resorption in vivo. MATERIAL AND METHODS: Four harvesting techniques were used: (i) corticocancellous blocks particulated by a bone mill; (ii) bone scraper; (iii) piezosurgery; and (iv) bone slurry collected from a filter device upon drilling. The grafts were placed into bone defects...

  10. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  11. Hematopoietic Stem Cell Transplantation in Primary Immunodeficiency Patients in the Black Sea Region of Turkey

    Directory of Open Access Journals (Sweden)

    Alişan Yıldıran

    2017-12-01

    Full Text Available Hematopoietic stem cell transplantation is a promising curative therapy for many combined primary immunodeficiencies and phagocytic disorders. We retrospectively reviewed pediatric cases of patients diagnosed with primary immunodeficiencies and scheduled for hematopoietic stem cell transplantation. We identified 22 patients (median age, 6 months; age range, 1 month to 10 years with various diagnoses who received hematopoietic stem cell transplantation. The patient diagnoses included severe combined immunodeficiency (n=11, Chediak-Higashi syndrome (n=2, leukocyte adhesion deficiency (n=2, MHC class 2 deficiency (n=2, chronic granulomatous syndrome (n=2, hemophagocytic lymphohistiocytosis (n=1, Wiskott-Aldrich syndrome (n=1, and Omenn syndrome (n=1. Of the 22 patients, 7 received human leukocyte antigen-matched related hematopoietic stem cell transplantation, 12 received haploidentical hematopoietic stem cell transplantation, and 2 received matched unrelated hematopoietic stem cell transplantation. The results showed that 5 patients had graft failure. Fourteen patients survived, yielding an overall survival rate of 67%. Screening newborn infants for primary immunodeficiency diseases may result in timely administration of hematopoietic stem cell transplantation.

  12. Hematopoietic Stem Cell Transplantation in Primary Immunodeficiency Patients in the Black Sea Region of Turkey.

    Science.gov (United States)

    Yıldıran, Alişan; Çeliksoy, Mehmet Halil; Borte, Stephan; Güner, Şükrü Nail; Elli, Murat; Fışgın, Tunç; Özyürek, Emel; Sancak, Recep; Oğur, Gönül

    2017-12-01

    Hematopoietic stem cell transplantation is a promising curative therapy for many combined primary immunodeficiencies and phagocytic disorders. We retrospectively reviewed pediatric cases of patients diagnosed with primary immunodeficiencies and scheduled for hematopoietic stem cell transplantation. We identified 22 patients (median age, 6 months; age range, 1 month to 10 years) with various diagnoses who received hematopoietic stem cell transplantation. The patient diagnoses included severe combined immunodeficiency (n=11), Chediak-Higashi syndrome (n=2), leukocyte adhesion deficiency (n=2), MHC class 2 deficiency (n=2), chronic granulomatous syndrome (n=2), hemophagocytic lymphohistiocytosis (n=1), Wiskott-Aldrich syndrome (n=1), and Omenn syndrome (n=1). Of the 22 patients, 7 received human leukocyte antigen-matched related hematopoietic stem cell transplantation, 12 received haploidentical hematopoietic stem cell transplantation, and 2 received matched unrelated hematopoietic stem cell transplantation. The results showed that 5 patients had graft failure. Fourteen patients survived, yielding an overall survival rate of 67%. Screening newborn infants for primary immunodeficiency diseases may result in timely administration of hematopoietic stem cell transplantation.

  13. Systems analysis determining critical items, critical assembly processes, primary failure modes and corrective actions on ASST magnets

    International Nuclear Information System (INIS)

    Arden, C.S.

    1993-04-01

    During the assembly process through the completion of the Accelerator Surface String Test (ASST) phase one test, Magnet Systems Division Reliability Engineering has tracked all the known discrepancies utilizing the Failure Reporting, Analysis and Corrective Action System (FRACAS) and data base. This paper discusses the critical items, critical assembly processes, primary failure modes and corrective actions (lessons learned) based on actual data for the ASST magnets. The ASST magnets include seven Brookhaven Lab Dipoles (DCA-207 through 213), fourteen Fermi Lab Dipoles (DCA-310 through 323) and five Lawrence Berkeley Lab Quadrupoles (QCC-402 through 406). Between all the ASST magnets built there were one hundred eighty six (186) class one discrepancies reported out of approximately eleven hundred total discrepancy reports. The class one or critical discrepancies are defined as form, fit, function, safety or reliability problem. Each and every ASST magnet is considered a success, as they all achieved the quench performance requirements and were capable of being incorporated into the string test. This paper also discuss some specific magnet discrepancies, including failure cause(s), corrective action and possible open issues

  14. Systems analysis determining critical items, critical assembly processes, primary failure modes and corrective actions on ASST magnets

    International Nuclear Information System (INIS)

    Arden, C.S.

    1994-01-01

    During the assembly process through the completion of the Accelerator Surface String Test (ASST) phase one test, Magnet Systems Division Reliability Engineering has tracked all the known discrepancies utilizing the Failure Reporting, Analysis and Corrective Action System (FRACAS) and data base. This paper discusses the critical items, critical assembly processes, primary failure modes and corrective actions (lessons learned) based on actual data for the ASST magnets. The ASST magnets include seven Brookhaven Lab Dipoles (DCA-207 through 213), fourteen Fermi Lab Dipoles (DCA-310 through 323) and five Lawrence Berkeley Lab Quadrupoles (QCC-402 through 406). Between all the ASST magnets built there were one hundred eighty six (186) class one discrepancies reported out of approximately eleven hundred total discrepancy reports. The class one or critical discrepancies are defined as form, fit, function, safety or reliability problem. Each and every ASST magnet is considered a success, as they all achieved the quench performance requirements and were capable of being incorporated into the string test. This paper will also discuss some specific magnet discrepancies, including failure cause(s), corrective action and possible open issues

  15. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  16. Comorbidities, risk factors and outcomes in patients with heart failure and an ejection fraction of more than or equal to 40% in primary care- and hospital care-based outpatient clinics.

    Science.gov (United States)

    Eriksson, B; Wändell, P; Dahlström, U; Näsman, P; Lund, L H; Edner, M

    2018-06-01

    The aim of this study is to describe patients with heart failure and an ejection fraction (EF) of more than or equal to 40%, managed in both Primary- and Hospital based outpatient clinics separately with their prognosis, comorbidities and risk factors. Further to compare the heart failure medication in the two groups. We used the prospective Swedish Heart Failure Registry to include 9654 out-patients who had HF and EF ≥40%, 1802 patients were registered in primary care and 7852 in hospital care. Descriptive statistical tests were used to analyze base line characteristics in the two groups and multivariate logistic regression analysis to assess mortality rate in the groups separately. The prospective Swedish Heart Failure Registry. Patients with heart failure and an ejection fraction (EF) of more than or equal to 40%. Comorbidities, risk factors and mortality. Mean-age was 77.5 (primary care) and 70.3 years (hospital care) p care group having more atrial fibrillation, hypertension, ischemic heart disease and COPD. According to the multivariate logistic regression analysis smoking, COPD and diabetes were the most important independent risk factors in the primary care group and valvular disease in the hospital care group. All-cause mortality during mean follow-up of almost 4 years was 31.5% in primary care and 27.8% in hospital care. One year-mortality rates were 7.8%, and 7.0% respectively. Any co-morbidity was noted in 97% of the HF-patients with an EF of more than or equal to 40% managed at primary care based out-patient clinics and these patients had partly other independent risk factors than those patients managed in hospital care based outpatients clinics. Our results indicate that more attention should be payed to manage COPD in the primary care group. KEY POINTS 97% of heart failure patients with an ejection fraction of more than or equal to 40% managed at primary care based out-patient clinics had any comorbidity. Patients in primary care had partly other

  17. Depth of the graft bed influences split-skin graft contraction.

    NARCIS (Netherlands)

    Mensik, I.; Lamme, E.N.; Brychta, P.

    2003-01-01

    Contraction of a split-thickness skin graft used for coverage of large defects remains a great problem in plastic, burn and reconstructive surgery. In this study we evaluated healing of split-thickness skin grafts transplanted in wounds on the subcutaneous fat and muscle fascia in pigs. Four young

  18. Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts

    International Nuclear Information System (INIS)

    Berggren, A.; Weiland, A.J.; Ostrup, L.T.

    1982-01-01

    Researchers studied the value of bone scintigraphy in the assessment of anastomotic patency and bone-cell viability in free bone grafts revascularized by microvascular anastomoses in twenty-seven dogs. The dogs were divided into three different groups, and scintigraphy was carried out using technetium-labeled methylene diphosphonate in composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and periosteal grafts placed in different recipient beds. The viability of the grafts were evaluated by histological examination and fluorescence microscopy after triple labeling with oxytetracycline on the first postoperative day, alizarin complexone on the fourth postoperative day, and DCAF on the eleventh postoperative day. A positive scintiscan within the first week following surgery indicated patent microvascular anastomoses, and histological study and fluorescence microscopy confirmed that bone throughout the graft was viable. A positive scintiscan one week after surgery or later does not necessarily indicate microvascular patency or bone-cell survival, because new bone formed by creeping substitution on the surface of a dead bone graft can result in this finding

  19. Nanohydroxyapatite Silicate-Based Cement Improves the Primary Stability of Dental Implants: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Hooman Khorshidi

    2017-01-01

    Full Text Available Objectives. Insufficient cortical bone volume when placing implants can lead to lack of primary stability. The use of cement as a bone fill material in bone defects around dental implant could result in better clinical outcome. HA has shown excellent biological properties in implant dentistry. The purpose of this study was to evaluate the effect of nanohydroxyapatite powder (Nano-HA in combination with accelerated Portland cement (APC on implant primary stability in surgically created circumferential bone defects in a bovine rib in vitro model. Materials and Methods. Sixteen bovine rib bones and thirty-six implants of same type and size (4 mm × 10 mm were used. Implants were divided into six groups: no circumferential bone defect, defect and no grafting, bone chips grafting, Nano-HA grafting, APC grafting, and Nano-HA mixed to APC grafting (Nano-HA-APC. Circumferential defects around the implants were prepared. The implant stability quotient (ISQ values were measured before and after the grafting. Results. APC exhibited the highest ISQ values. A significant increase of ISQ values following the grafting of Nano-HA-APC (18.08±5.82 and APC alone (9.50±4.12 was achieved. Increase of ISQ values after 72 hours was 24.16±5.01 and 17.58±4.89, respectively. Nano-HA grafting alone exhibited the least rise in ISQ values. Conclusions. Nanohydroxyapatite silicate-based cement could improve the primary stability of dental implants in circumferential bone defect around implants.

  20. Grafting of phosphorylcholine functional groups on polycarbonate urethane surface for resisting platelet adhesion

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Bin [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Feng, Yakai, E-mail: yakaifeng@hotmail.com [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Tianjin University-Helmholtz-Zentrum Geesthacht, Joint Laboratory for Biomaterials and Regenerative Medicine, Weijin Road 92, 300072 Tianjin (China); Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Lu, Jian; Zhang, Li; Zhao, Miao; Shi, Changcan; Khan, Musammir [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Guo, Jintang [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Tianjin University-Helmholtz-Zentrum Geesthacht, Joint Laboratory for Biomaterials and Regenerative Medicine, Weijin Road 92, 300072 Tianjin (China)

    2013-07-01

    In order to improve the resistance of platelet adhesion on material surface, 2-methacryloyloxyethyl phosphorylcholine (MPC) was grafted onto polycarbonate urethane (PCU) surface via Michael reaction to create biomimetic structure. After introducing primary amine groups via coupling tris(2-aminoethyl)amine (TAEA) onto the polymer surface, the double bond of MPC reacted with the amino group to obtain MPC modified PCU. The modified surface was characterized by Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS). The results verified that MPC was grafted onto PCU surface by Michael reaction method. The MPC grafted PCU surface had a low water contact angle and a high water uptake. This means that the hydrophilic PC functional groups improved the surface hydrophilicity significantly. In addition, surface morphology of MPC grafted PCU film was imaged by atomic force microscope (AFM). The results showed that the grafted surface was rougher than the blank PCU surface. In addition, platelet adhesion study was evaluated by scanning electron microscopy (SEM) observation. The PCU films after treated with platelet-rich plasma demonstrated that much fewer platelets adhered to the MPC-grafted PCU surface than to the blank PCU surface. The antithrombogenicity of the MPC-grafted PCU surface was determined by the activated partial thromboplastin time (APTT). The result suggested that the MPC modified PCU may have potential application as biomaterials in blood-contacting and some subcutaneously implanted devices. - Highlights: • MPC was successfully grafted onto polycarbonate urethane surface via Michael reaction. • High concentration of PC functional groups on the surface via TAEA molecule • Biomimetic surface modification • The modified surface showed high hydrophilicity and anti-platelet adhesion.

  1. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  2. Hydrophilic/hydrophobic character of grafted cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Takacs, E., E-mail: takacs@iki.kfki.h [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Wojnarovits, L. [Institute of Isotopes, Hungarian Academy of Sciences, Budapest (Hungary); Borsa, J. [Budapest University of Technology and Economics (Hungary); Racz, I. [Bay Zoltan Institute for Materials Science and Technology, Budapest (Hungary)

    2010-04-15

    Vinyl monomers with long paraffin chains were grafted onto two kinds of cellulose (cotton and cotton linter) by direct irradiation grafting technique. The effect of dose, monomer structure and concentration, as well as homopolymer suppressor (styrene) concentration on the grafting yield was studied and the optimal grafting conditions were established. Grafting decreased the swelling of the samples in water and increased their polymer compatibility in polypropylene matrix.

  3. Allograft tissue irradiation and failure rate after anterior cruciate ligament reconstruction: A systematic review.

    Science.gov (United States)

    Dashe, Jesse; Parisien, Robert L; Cusano, Antonio; Curry, Emily J; Bedi, Asheesh; Li, Xinning

    2016-06-18

    To evaluate whether anterior cruciate ligament (ACL) allograft irradiation is effective for sterility without compromising graft integrity and increasing failure rate. A literature search was conducted using PubMed, Cochrane, and Google. The following search terms were used: "Gamma irradiation AND anterior cruciate ligament AND allograft" with a return of 30 items. Filters used included: English language, years 1990-2015. There were 6 hits that were not reviewed, as there were only abstracts available. Another 5 hits were discarded, as they did not pertain to the topic of interest. There were 9 more articles that were excluded: Three studies were performed on animals and 6 studies were meta-analyses. Therefore, a total of 10 articles were applicable to review. There is a delicate dosing crossover where gamma irradiation is both effective for sterility without catastrophically compromising the structural integrity of the graft. Of note, low dose irradiation is considered less than 2.0 Mrad, moderate dose is between 2.1-2.4 Mrad, and high dose is greater than or equal to 2.5 Mrad. Based upon the results of the literature search, the optimal threshold for sterilization was found to be sterilization at less than 2.2 Mrad of gamma irradiation with the important caveat of being performed at low temperatures. The graft selection process also must include thorough donor screening and testing as well as harvesting the tissue in a sterile fashion. Utilization of higher dose (≥ 2.5 Mrad) of irradiation causes greater allograft tissue laxity that results in greater graft failure rate clinically in patients after ACL reconstruction. Allograft ACL graft gamma irradiated with less than 2.2 Mrad appears to be a reasonable alternative to autograft for patients above 25 years of age.

  4. The predictive value of angiographic results for the outcome of percutaneous transluminal angioplasty in stenosed femoral bypass grafts

    International Nuclear Information System (INIS)

    Spijkerboer, Anje M.; Beek, Frederik J. A.; Graaf, Yolanda van der; Eikelboom, Bert C.; Mali, Willem P. T. M.

    1997-01-01

    Purpose. To assess the predictive value of immediate angiographic results after percutaneous transluminal angioplasty (PTA) for stenoses in femoral bypass grafts using duplex ultrasound (DUS) criteria. Methods. A 1-year follow-up with DUS was performed in 38 patients with 50 stenoses in 41 grafts, treated with PTA for a graft stenosis. The indication for PTA according to DUS criteria was a severe stenosis in 43 lesions, and a moderate stenosis in 7 lesions. In the moderate stenosis group 3 patients showed claudication and 1 patient had a nonhealing ulcer. For the purposes of statistical evaluation, primary patency was considered present if the graft was not occluded. The graft was considered to have failed when it was found to be occluded on DUS, or when secondary interventions (surgery, repeat PTA) were performed. Results. After 1 year the cumulative primary patency rate was 44$ [95% confidence interval (CI) 27.8-59.8]. Stenoses with initially good angiographic results after PTA (<30% residual stenosis) were 2.9 times more likely to be patent at 1 year than stenoses with initially poor or moderate angiographic results (hazard ratio 2.9, 95% CI 1.3-6.4,p=0.007). Conclusion. A poor or moderate angiographic result immediately following PTA was prognostic for poor long-term results and may indicate a requirement for earlier surgical intervention

  5. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  6. Surgical approach to end-stage heart failure.

    Science.gov (United States)

    Klotz, Stefan; Scheld, Hans H

    2011-02-01

    End-stage heart failure is a challenging disease with growing incidence. With decreasing heart transplant rates worldwide organ preserving therapies become, again, of interest. The purpose of the present review is to examine the potential challenges of surgical therapies in patients with end-stage heart failure. The gold-standard for end-stage heart failure is and will be cardiac transplantation. However, due to organ shortage this therapy is limited to a few patients. Therefore implantation of ventricular assist devices (VADs) or long-term minimal-invasive partial support devices will increase. Improvements in device design with smaller devices, easier implantation techniques, and modified anticoagulation outcome and long-term success will likely improve. In addition, good quality of life as destination therapy is almost available. Organ conservation surgery (coronary artery bypass grafting and surgical ventricular restoration or surgical repair of mitral valve regurgitation) in end-stage heart failure patients could not prove the expected results. Transcatheter or minimal-invasive approaches of these therapies might become routine in the near future. Due to the overwhelming outcome rates, cardiac transplantation is the most established surgical therapy for end-stage heart failure. VAD therapy is increasing and minimized VADs might further open the market for destination therapy/permanent support.

  7. Comparison of Puddu osteotomy with or without autologous bone grafting: a prospective clinical trial

    Directory of Open Access Journals (Sweden)

    Marcus Ceregatti Passarelli

    Full Text Available ABSTRACT Objectives: To test the hypothesis that autologous iliac bone grafts do not enhance clinical results and do not decrease complication rates in patients undergoing medial opening-wedge high tibial , osteotomy. Methods: Forty patients allocated in a randomized, two-armed, double-blinded clinical trial were evaluated between 2007 and 2010. One group received bone graft, and the other group was left without filling the osteotomy defect. The primary outcome was the Knee Society Score. , Radiographic measurement of the frontal anatomical femoral-tibial angle and the progression of osteoarthritis according to the modified Ahlback classification were used as secondary outcomes., Results: There was no difference in KSS scale between the graft group (64.4 ± 21.8 and the graftless group (61.6 ± 17.3; p= 0.309. There was no difference of angle between the femur and tibia in the frontal plane between the groups (graft, = 184 ± 4.6 degrees, graftless = 183.4 ± 5.1 degrees; p= 1.0, indicating that there is no loss of correction due to the lack of the graft. There was significant aggravation of osteoarthritis in a greater number of patients in a graft group (p= 0.005 . Conclusion: Autologous iliac bone graft does not improve clinical outcomes in medium and long-term follow-up of medial opening-wedge high tibial osteotomy fixed with a first generation Puddu plate in the conditions of this study.

  8. Calcar femorale grafting in the hemiarthroplasty of the hip for unstable inter trochanteric fractures.

    Science.gov (United States)

    Thakkar, Chandrashekar J; Thakkar, Savyasachi; Kathalgere, Rajshekhar T; Kumar, Malhar N

    2015-01-01

    The sliding screw-plate devices and cephalo-medullary nail devices have performed well in stable inter-trochanteric fractures in patients with reasonably good quality of bone. However, their suboptimal performance in comminuted fractures in the presence of osteoporotic bone has prompted many surgeons to consider bipolar hemiarthroplasty as the primary modality of management of comminuted inter-trochanteric fractures in elderly patients. However, long term stability of the hemiarthroplasty implant also may be compromised due to the presence of postero-medial bone loss at the area of the calcar. We have presented a simple and effective technique of calcar grafting by harvesting cortical bone strut from the neck of the fractured femur. A total of 34 patients with inter-trochanteric fractures of the femur were treated with calcar grafting. The mean age was 79.2 years. The graft was harvested from the calcar region of the head and neck fragment of the femur and wedged between the medial femoral cortex and medial edge of the prosthesis. The mean followup period was 54.5 months. In 32 of 34 (94%) patients in our series, the calcar graft healed well without dislodgement. There was graft resorption in two patients associated with subsidence of the implant and loosening. Calcar grafting using this technique provides stability to the implant in the presence of comminution and incorporates well in the majority of patients. Donor site morbidity of graft harvesting is also avoided.

  9. Treatment of midshaft clavicular nonunion with plate fixation and autologous bone grafting

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Vaesel, M T; Søjbjerg, Jens Ole

    1995-01-01

    We studied the results of 16 consecutive midshaft clavicular nonunions operated on at the Shoulder and Elbow Clinic during the period from 1990 to 1993. All patients were treated with rigid 3.5 mm plate fixation and autologous cancellous bone grafting. Union of the fractures was achieved in all...... except one case, with a reconstruction ratio (restoration of bone length) of 0.96 (range 0.88 to 1.03). At follow-up 12 of 16 patients had returned to their preinjury activity level and according to the Constant score had obtained an excellent result. Two patients were graded as good, one as fair......, and one had a failure. Thirteen of 16 patients were satisfied with the cosmetic outcome, assessing their cosmetic result as either good or excellent. Rigid plate fixation and restoration of clavicular length with autologous cancellous bone graft is recommended for the treatment of symptomatic clavicular...

  10. The failure of suicide prevention in primary care: family and GP perspectives - a qualitative study.

    Science.gov (United States)

    Leavey, Gerard; Mallon, Sharon; Rondon-Sulbaran, Janeet; Galway, Karen; Rosato, Michael; Hughes, Lynette

    2017-11-21

    Although Primary care is crucial for suicide prevention, clinicians tend to report completed suicides in their care as non-preventable. We aimed to examine systemic inadequacies in suicide prevention from the perspectives of bereaved family members and GPs. Qualitative study of 72 relatives or close friends bereaved by suicide and 19 General Practitioners who have experienced the suicide of patients. Relatives highlight failures in detecting symptoms and behavioral changes and the inability of GPs to understand the needs of patients and their social contexts. A perceived overreliance on anti-depressant treatment is a major source of criticism by family members. GPs tend to lack confidence in the recognition and management of suicidal patients, and report structural inadequacies in service provision. Mental health and primary care services must find innovative and ethical ways to involve families in the decision-making process for patients at risk of suicide.

  11. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    Science.gov (United States)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-06-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time.

  12. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    International Nuclear Information System (INIS)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-01-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time

  13. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  14. Environmental application of radiation grafting

    International Nuclear Information System (INIS)

    Tamada, Masao

    2007-01-01

    Adsorbent having high selectivity against a certain metal ion was synthesized by means of radiation-induced graft polymerization for the purpose of environmental application. The resulting adsorbents were utilized for the removal of toxic metal from scallop waste and the collection of uranium from seawater. As a novel application of grafting, the biodegradability of poly-hydroxybutylate was controlled by grafting. The biodegradability could be depressed by the graft chain and then recovered by external stimuli such as thermal and chemical treatments. (author)

  15. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  16. Pattern and predictors of dual antiplatelet use after coronary artery bypass graft surgery.

    Science.gov (United States)

    Mori, Makoto; Shioda, Kayoko; Yun, James J; Mangi, Abeel A; Darr, Umer; Geirsson, Arnar

    2018-02-01

    Resumption of dual antiplatelet therapy after coronary artery bypass grafting in patients presenting with acute coronary syndrome is recommended, but the current practice pattern in the United States remains unknown. We aimed to investigate the current pattern of dual antiplatelet therapy use after coronary artery bypass grafting at the Yale-New Haven Hospital. We conducted a single-center retrospective review of patients who presented with acute coronary syndrome and underwent coronary artery bypass grafting between 2014 and 2016. The primary outcome was hospital discharge with dual antiplatelet therapy. Mixed-effect multivariate logistic regression was used to evaluate predictors of dual antiplatelet therapy use or nonuse, accounting for surgeon-specific preference. The discriminatory ability of the model was evaluated with receiver operating characteristics analysis. Of 572 patients included, only 29% were discharged with dual antiplatelet therapy. In the mixed-effect multivariate model isolating surgeon preferences, increase in age (odds ratio, 0.95; 95% confidence interval, 0.92-0.98; P dual antiplatelet therapy use. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting was associated with increased odds of dual antiplatelet therapy use (odds ratio, 31.5; 95% confidence interval, 12.8-77.2; P dual antiplatelet therapy use in patients with acute coronary syndrome who underwent coronary artery bypass grafting was low and variable among surgeons. The use or nonuse was guided by previously established risk factors of recurrent ischemia and bleeding, along with surgeon preference. Published by Elsevier Inc.

  17. Genome-wide assessment for genetic variants associated with ventricular dysfunction after primary coronary artery bypass graft surgery.

    Directory of Open Access Journals (Sweden)

    Amanda A Fox

    Full Text Available BACKGROUND: Postoperative ventricular dysfunction (VnD occurs in 9-20% of coronary artery bypass graft (CABG surgical patients and is associated with increased postoperative morbidity and mortality. Understanding genetic causes of postoperative VnD should enhance patient risk stratification and improve treatment and prevention strategies. We aimed to determine if genetic variants associate with occurrence of in-hospital VnD after CABG surgery. METHODS: A genome-wide association study identified single nucleotide polymorphisms (SNPs associated with postoperative VnD in male subjects of European ancestry undergoing isolated primary CABG surgery with cardiopulmonary bypass. VnD was defined as the need for ≥2 inotropes or mechanical ventricular support after CABG surgery. Validated SNPs were assessed further in two replication CABG cohorts and meta-analysis was performed. RESULTS: Over 100 SNPs were associated with VnD (P2.1 of developing in-hospital VnD after CABG surgery. However, three genetic loci identified by meta-analysis were more modestly associated with development of postoperative VnD. Studies of larger cohorts to assess these loci as well as to define other genetic mechanisms and related biology that link genetic variants to postoperative ventricular dysfunction are warranted.

  18. Tube Stent-Grafts for Infrarenal Aortic Aneurysm: A Matched-Paired Analysis Based on EUROSTAR Data

    International Nuclear Information System (INIS)

    Ruppert, Volker; Leurs, Lina J.; Hobo, Roel; Buth, Jacob; Rieger, Johannes; Umscheid, Thomas

    2007-01-01

    Objective. Tube stent-grafts for treatment of infrarenal aortic aneurysms (AAAs) are a nearly forgotten concept. For focal aortic pathologies tube stent-grafts may be a treatment option. We have performed a retrospective matched-paired analysis of the EUROSTAR registry regarding the outcome of tube vs. bifurcated stent-grafts for AAA. Tapered aortomonoiliac stent-grafts were not the objective of this study. Materials and methods. From July 1997 to June 2006, 7581 patients who underwent an endovascular AAA repair were entered in the EUROSTAR registry by 164 centers. One hundred fifty-three patients were treated with tube stent-grafts. For each of these 153 patients we selected one patient from a bifurcated stent-graft group (BGG-original, 7428 patients) matched according to gender, ASA, age, AAA diameter, and type of anesthesia. Differences in preoperative details between the two study groups were analyzed using chi-square test for discrete variables and Wilcoxon rank-sum test for continuous variables. Multivariate logistic regression analysis was performed on early complications. Midterm outcomes (>30 days) were analyzed by Kaplan-Meier and multivariate Cox proportional hazard model. Results. The duration of the procedure was shorter in the tube stent-graft group (TGG; 102.3 ± 52.2) than in BGG (128.3 ± 55.0; p 0.0002). Type II endoleak was less frequent in TGG (4.0%; mean follow-up, 23.12 ± 23.9 months) than in BGG (14.3%; mean follow-up, 20.77 ± 20.0 months; p = 0.0394). Type I endoleaks and migration were distributed equally, without significant differences between the groups. Combined 30-day and late mortality was higher for TGG (p = 0.0346) and was obviously not aneurysm related. Conclusions. We conclude that after selection of patients, tube stent-grafts for infrarenal aortic repair can be performed with great safety regarding endoleaks and migration. The combined higher 30-day mortality and non-aneurysm-related mortality during follow-up were mainly

  19. Graft-copolymerization onto carbon black

    International Nuclear Information System (INIS)

    Nakase, Yoshiaki; Nishii, Masanobu; Kijima, Toshiyuki; Kato, Hiroshi.

    1988-07-01

    Radiation-induced graft copolymerization of vinyl monomer onto carbon black was performed. During the γ-ray- and electron beam-induced polymerization (In-source), or the electron beam post-polymerization, the graft-copolymerization behavior was affected by the kinds of both carbon blacks and monomers, i.e. the smaller the size of carbon black particles, the higher the apparent grafted fraction. Homopolymer in the grafted carbon black samples was washed out by the solvent of the polymer, and the extracted polymer seemed to be dimer or trimer of the used monomer. In the case of the post-polymerization with the pre-irradiation doses of 50 Mrad, homopolymer was hardly observed. The polymer sheets of plastics or rubbers with grafted carbon black had an electrical conductivity unalterable considerably by the heating cycles. The particles of grafted carbon black in the sheet might be kept much more at the surface layer within 100 nm depth than at the inner layer. (author)

  20. FAS grafted superhydrophobic ceramic membrane

    Science.gov (United States)

    Lu, Jun; Yu, Yun; Zhou, Jianer; Song, Lixin; Hu, Xingfang; Larbot, Andre

    2009-08-01

    The hydrophobic properties of γ-Al 2O 3 membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 °C) of the fluoroalkylsilane grafted on Al 2O 3 powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and γ-Al 2O 3 membrane surface as well as the formed surface morphology.

  1. Radiation-induced grafting of TMPM onto polypropylene

    International Nuclear Information System (INIS)

    Wang Huiliang; Li Hong; Chen Wenxiu

    1995-01-01

    The gamma radiation-induced graft copolymerization of 2,2,6,6-tetramethyl-4-piperidinyl-methacrylate (TMPM), a very effective hindered amine light stabilizer (HALS), onto polypropylene was investigated by simultaneous- irradiation technique. The various synthesis conditions on the graft content was studied. It was found that benzene, CCl 4 and petroleum ether are more effective than other solvents, the percent grafting reached 7.1% for benzene. The percent grafting is higher when graft copolymerization is carried out in argon atmosphere than those in air. For all the grafting copolymerization carried out in benzene and CCl 4 , percent grafting increase linearly from 1 to 5 Mrad and beyond 5 Mrad, a tendency to level off appeared. At a constant dose, the percent grafting was found to be higher at high dose rate until 228 rad/s. Percent grafting also increased continuously with increasing monomer concentration up to 2.85 mol/L, but significant increase in grafting was observed only up to 1.14 mol/L

  2. Salt-Induced Control of the Grafting Density in Poly(ethylene glycol) Brush Layers by a Grafting-to Approach

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Olsen, Stefan; Thormann, Esben

    2018-01-01

    In this work, a method to obtain control of the grafting density during the formation of polymer brush layers by the grafting-to method of thiolated poly(ethylene glycol) onto gold is presented. The grafting density of the polymer chains was adjusted by adding Na2SO4 in concentrations between 0.......2 and 0.9 M to the aqueous polymer solution during the grafting process. The obtained grafting densities ranged from 0.26 to 1.60 chains nm-2, as determined by surface plasmon resonance. The kinetics of the grafting process were studied in situ by a quartz crystal microbalance with dissipation......, and a mushroom to brush conformational transition was observed when the polymer was grafted in the presence of Na2SO4. The transition from mushroom to brush was only observed for long periods of grafting, highlighting the importance of time to obtain high grafting densities. Finally, the prepared brush layer...

  3. Studies on radiation-induced graft polymerization

    International Nuclear Information System (INIS)

    Omichi, Hideki

    1978-09-01

    Radiation-induced graft polymerization is used extensively to improve physical properties of polymers, but few processes are now commercialized. The reason for this is partly inadequate basic research on the reaction and partly the difficulty in developing the grafting process with large radiation source. Firstly, new techniques are proposed of studying kinetics of the graft polymerization in heterogeneous system. Based on the grafting yield, the molecular weight of graft chains, and the amount of radicals given by ESR and activation analysis, kinetic parameters are obtained and the reaction mechanism of grafting process is discussed. Secondly, the development of grafting process of poly (vinyl chloride)-butadiene is described. By study of the reaction, process design, construction and operation of the pilot plant, and economic analysis of the process, this process with 60 Co gamma ray sources is shown to be industrially promising. (author)

  4. Development of Highly Efficient Grafting Technique and Synthesis of Natural Polymer-Based Graft Adsorbent

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Y; Seko, N; Tamada, M [Japan Atomic Energy Agency, Quantum Beam Science Directorate, Takasaki (Japan)

    2012-09-15

    In the framework of the CRP, Japan has focused on the development of fibrous adsorbents for removal of toxic metal ions and recovery of significant metal ions from industrial wastewater and streaming water. Graft polymerization was carried out by using gamma irradiation facility and electron beam accelerator. Emulsion grafting is a novel topic for synthesis of metal ion adsorbents which are prepared from fibrous trunk polymers such as polyethylene fibre and biodegradable nonwoven fabrics. The emulsion grafting, where monomer micelles are dispersed in water in the presence of surfactant, is a highly efficient and economic grafting technique as compared to general organic solvent system. The resultant cotton-based adsorbent has high adsorption efficiency and high adsorption capacity for Hg, besides, it is biodegradable. Polylactic acid can also be used as a trunk material for the grafting. (author)

  5. Protocol for a systematic review of the efficacy of fat grafting and platelet-rich plasma for wound healing.

    Science.gov (United States)

    Smith, Oliver J; Kanapathy, Muholan; Khajuria, Ankur; Prokopenko, Max; Hachach-Haram, Nadine; Mann, Haroon; Mosahebi, Ash

    2017-06-06

    The use of fat grafting as a reconstructive surgical option is becoming much more common. Adipose-derived stem cells found in fat grafts are believed to facilitate wound healing via differentiation into fibroblasts and keratinocytes and the release of pro-healing growth factors. Several small studies have shown a positive effect of fat grafting in healing of wounds of a variety of aetiologies. When fat is combined with autologous platelet-rich plasma (PRP), there may be enhanced healing effects. This may be due to the pro-angiogenic and anti-inflammatory effects of PRP. We aim to synthesise the current evidence on combination fat grafting and PRP for wound healing to establish the efficacy of this technique. We will conduct a comprehensive literature search in the MEDLINE, EMBASE, CENTRAL, Science Citation Index, and Google Scholar databases (up to July 2017) to identify studies on fat grafting and PRP for wound healing. All primary studies and systematic reviews of these studies will be included, except case reports and case series with fewer than three patients, to evaluate the outcome of fat grafting and PRP on wound healing either on its own or when compared to other studies. Primary outcome measures are expected to be the proportion of total wounds healed at 12 weeks and the average wound healing time (time for 100% re-epithelialisation). Expected secondary outcome measures are the proportion of wounds achieving 50% wound healing, the type of wound benefitting most from fat grafting, economic evaluation, health-related quality of life, and adverse events. Subgroup analysis will be performed for the proportions of wounds healed based on wound aetiology. This review will provide robust evidence of the efficacy of fat grafting and PRP for wound healing. This is an emerging technique, and this review is expected to guide clinical practice and ongoing research aimed at improving wound care. PROSPERO CRD42016049881.

  6. Design of a Sapling Branch Grafting Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available The automatic sapling grafting methods and grafting robot technologies are not comprehensively studied despite the fact that they are urgently required in practice. For this reason, a sapling grafting robot is developed to implement automatic grafting for saplings. The developed grafting robot includes clipping mechanism, moving mechanism, cutting mechanism, binding mechanism, and Arduino MCU based control system, which is capable of clipping, moving, positioning, cutting, grafting, and binding saplings. Experiments show that the stock cutting efficiency is 98.4%, the scion cutting efficiency is 98.9%, the grafting efficiency is 87.3%, and the binding efficiency is 68.9%.

  7. Fat Grafting for Facial Filling and Regeneration.

    Science.gov (United States)

    Coleman, Sydney R; Katzel, Evan B

    2015-07-01

    Plastic surgeons have come to realize that fat grafting can rejuvenate an aging face by restoring or creating fullness. However, fat grafting does much more than simply add volume. Grafted fat can transform or repair the tissues into which it is placed. Historically, surgeons have hesitated to embrace the rejuvenating potential of fat grafting because of poor graft take, fat necrosis, and inconsistent outcomes. This article describes fat grafting techniques and practices to assist readers in successful harvesting, processing, and placement of fat for optimal graft retention and facial esthetic outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  9. miRNA-21 is dysregulated in response to vein grafting in multiple models and genetic ablation in mice attenuates neointima formation

    NARCIS (Netherlands)

    McDonald, Robert A; White, Katie M; Wu, Junxi; Cooley, Brian C; Robertson, Keith E; Halliday, Crawford A; McClure, John D; Francis, Sheila; Lu, Ruifaug; Kennedy, Simon; George, Sarah J; Wan, Song; van Rooij, Eva; Baker, Andrew H

    AIMS: The long-term failure of autologous saphenous vein bypass grafts due to neointimal thickening is a major clinical burden. Identifying novel strategies to prevent neointimal thickening is important. Thus, this study aimed to identify microRNAs (miRNAs) that are dysregulated during neointimal

  10. Determination of grafting conversion degree in PS/PS-graft-POSS/POSS hybrid nanocomposites obtained through reactive processing

    International Nuclear Information System (INIS)

    Bianchi, Otavio; Repenning, Gustavo B.; Mauler, Raquel S.; Oliveira, Ricardo V.B.; Canto, Leonardo B.

    2011-01-01

    Hybrid nanocomposites of polystyrene (PS) and polyhedral oligomeric silsesquioxanes (POSS) - PS/PS-graft-POSS/POSS - with different grafting degrees were prepared by reactive melt processing using dicumyl peroxide (DCP) as initiator in the presence or absence of styrene monomer as radical transfer agent. Gel permeation chromatography (GPC) using triple-detector and proton nuclear magnetic resonance (NMR 1 H) analyses were used together to determine the conversion degree of PS-graft-POSS as a function of the reactive processing conditions adopted. GPC was employed to evaluate the effects of grafting (PS-graft-POSS) and PS chains degradation (β scission) that occur simultaneously during processing on the variation of average molecular masses and distributions for each PS/POSS sample. PS/POSS systems processed with styrene showed higher weight average molecular weights (M w ) and lower polydispersity indexes (M w /M n ), as a result of higher grafting (PS-graft-POSS) conversion (28-40%) and lower PS chain degradation level, as compared to PS/POSS systems processed without styrene in which the degree of grafting conversion was around 25-28%. (author)

  11. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  12. A study on the morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method

    International Nuclear Information System (INIS)

    Song, Ju-Myung; Ko, Beom-Seok; Sohn, Joon-Yong; Nho, Young Chang; Shin, Junhwa

    2014-01-01

    The morphology of polystyrene-grafted poly(ethylene-alt-tetrafluoroethylene) (ETFE) films prepared using a simultaneous radiation grafting method was investigated using DMA, DSC, XRD, and SAXS instruments. The DMA study indicates that the ETFE amorphous phase and PS amorphous phase are mixed well in the PS-grafted ETFE films while the ETFE crystalline phase and the PS amorphous phase are separated, suggesting that the PS chains are grafted mainly on the ETFE amorphous regions. The DSC and XRD data showed that the natural crystalline structures of ETFE in the grafted ETFE films are not affected by the degree of grafting. The SAXS profiles displayed that the inter-crystalline distance of the ETFE films increases with an increasing degree of grafting, which further implies that the PS graft chains formed by the simultaneous irradiation has a significant impact on the amorphous morphology of the resulting grafted ETFE film. Thus, these results indicate that the styrene monomers are mainly grafted on the ETFE amorphous regions during the simultaneous radiation grafting process. - Highlights: • PS-grafted ETFE films were prepared by a simultaneous radiation grafting method was investigated. • The natural crystalline structures of grafted ETFE films are not affect by the degree of grafting. • The inter-crystalline distance of the ETFE films increase with increasing degree of grafting. • The styrene monomers are mainly grafted on the ETFE amorphous regions during a simultaneous radiation grafting using gamma-ray

  13. Survival of dental implants in native and grafted bone in irradiated head and neck cancer patients: a retrospective analysis.

    Science.gov (United States)

    Buddula, Aravind; Assad, Daniel A; Salinas, Thomas J; Garces, Yolanda I

    2011-01-01

    To study the long-term survival of dental implants placed in native or grafted bone in irradiated bone in subjects who had received radiation for head and neck cancer. A retrospective chart review was conducted for all patients who received dental implants following radiation treatment for head and neck cancer between May 1, 1987 and July 1, 2008. Only patients irradiated with a radiation dose of 50 Gy or greater and those who received dental implants in the irradiated field after head and neck radiation were included in the study. The associations between implant survival and patient/implant characteristics were estimated by fitting univariate marginal Cox proportional hazards models. A total of 48 patients who had prior head and neck radiation had 271 dental implants placed during May 1987-July 2008. There was no statistically significant difference between implant failure in native and grafted bone (P=0.76). Survival of implants in grafted bone was 82.3% and 98.1% in maxilla and mandible, respectively, after 3 years. Survival of implants in native bone in maxilla and mandible was 79.8% and 100%, respectively, after 3 years. For implants placed in the native bone, there was a higher likelihood of failure in the maxilla compared to the mandible and there was also a tendency for implants placed in the posterior region to fail compared to those placed in the anterior region. There was no significant difference in survival when implants were placed in native or grafted bone in irradiated head and neck cancer patients. For implants placed in native bone, survival was significantly influenced by the location of the implant (maxilla or mandible, anterior or posterior).

  14. Comparative Efficacy of Pulse-Spray Thrombolysis and Angioplasty Versus Surgical Salvage Procedures for Treatment of Recurrent Occlusion of PTFE Dialysis Access Grafts

    International Nuclear Information System (INIS)

    Polak, Joseph F.; Berger, Markus F.; Pagan-Marin, Heriberto; Aruny, John E.; Meyerovitz, Michael F.

    1998-01-01

    Purpose: To compare the efficacy of surgery versus pulse-spray thrombolysis and angioplasty in patients with recurrent thrombosis of polytetrafluoroethylene (PTFE) dialysis access grafts. Methods: We analyzed 96 consecutive interventions for thrombosed PTFE dialysis access grafts in 18 patients. Primary patency after thrombolysis and angioplasty (n= 25) was compared with primary patency following thrombectomy alone (n= 50) or thrombectomy followed by graft revision (n= 21) using life-table analysis. A Cox proportional hazards model that accounted for graft age and number of previous interventions was used to generate the relative risk for recurrent occlusion following therapy. Results: Life-table analysis showed that patency after thrombolysis and angioplasty was greater than that following thrombectomy alone (p= 0.02). After accounting for the age of the graft and the number of previous interventions (average six per patient), the relative risk for recurrent occlusion [3.0; 95% confidence intervals (CI): 1.5, 6.4] was greater for thrombectomy alone than for thrombolysis/angioplasty [0.6; CI = 0.3, 1.3]. The relative risks of repeat occlusion following thrombolysis/angioplasty [0.6; CI = 0.3, 1.3] and thrombectomy/surgical revision [1.0; CI = 0.5, 1.7] were similar. Conclusion: Outcome data from our retrospective study on recurrent thrombosis of PTFE dialysis access grafts suggest that thrombolysis/angioplasty is superior to thrombectomy alone, and equivalent to thrombectomy/surgical revision

  15. FAS grafted superhydrophobic ceramic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Yu Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Zhou Jianer [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Song Lixin; Hu Xingfang [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Larbot, Andre [Institut Europeen des Membranes, UMR 5635-CNRS, ENSCM, UMII, 1919 Route de Mende 34293, Montpellier Cedex 5 (France)

    2009-08-30

    The hydrophobic properties of {gamma}-Al{sub 2}O{sub 3} membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 deg. C) of the fluoroalkylsilane grafted on Al{sub 2}O{sub 3} powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and {gamma}-Al{sub 2}O{sub 3} membrane surface as well as the formed surface morphology.

  16. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  17. Emerging concepts in liver graft preservation

    Science.gov (United States)

    Bejaoui, Mohamed; Pantazi, Eirini; Folch-Puy, Emma; Baptista, Pedro M; García-Gil, Agustín; Adam, René; Roselló-Catafau, Joan

    2015-01-01

    The urgent need to expand the donor pool in order to attend to the growing demand for liver transplantation has obliged physicians to consider the use of suboptimal liver grafts and also to redefine the preservation strategies. This review examines the different methods of liver graft preservation, focusing on the latest advances in both static cold storage and machine perfusion (MP). The new strategies for static cold storage are mainly designed to increase the fatty liver graft preservation via the supplementation of commercial organ preservation solutions with additives. In this paper we stress the importance of carrying out effective graft washout after static cold preservation, and present a detailed discussion of the future perspectives for dynamic graft preservation using MP at different temperatures (hypothermia at 4 °C, normothermia at 37 °C and subnormothermia at 20 °C-25 °C). Finally, we highlight some emerging applications of regenerative medicine in liver graft preservation. In conclusion, this review discusses the “state of the art” and future perspectives in static and dynamic liver graft preservation in order to improve graft viability. PMID:25593455

  18. [Penile augmentation and elongation using autologous dermal-fat strip grafting].

    Science.gov (United States)

    Yang, Zhe; Li, Yang-qun; Tang, Yong; Chen, Wen; Li, Qiang; Zhou, Chuan-de; Zhao, Mu-xin; Hu, Chun-mei

    2012-05-01

    To investigate the effect of autologous dermal-fat strip grafting in penile augmentation and elongation. From May 2004 to December 2010, 24 patients underwent penile enhancement with free dermal-fat strip grafting. Through suprapubic incision, the superior suspensory ligament and part deep suspensory ligament are cutted off to lengthen the penis. The resulted dead space is filled with the autologous dermal-fat strip (6.0-9.5 cm in length, 1.2-1.5 cm in width and 0.6-0.8 cm in depth) to enhance the penis. Primary healing was achieved in 23 cases. Incisional fat liquefaction happened in one case which healed after dressing change. The penile appearance was satisfactory both at rest or erection. The penile length and circumference increased by 2.5-4.8 cm (average, 3.2 cm) and 1.8-3.0 cm (average, 2.4 cm), respectively. 18 patients were followed up for 3 months to 5 years. All the patients were satisfactory on the cosmetic and functional results. No complication happened. It is safe and effective for penile augmention and elongation with autologous dermal-fat strip grafting and disconnection of penile suspensory ligament.

  19. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  20. Clinically relevant diagnostic research in primary care: the example of B-type natriuretic peptides in the detection of heart failure.

    Science.gov (United States)

    Kelder, Johannes C; Rutten, Frans H; Hoes, Arno W

    2009-02-01

    With the emergence of novel diagnostic tests, e.g. point-of-care tests, clinically relevant empirical evidence is needed to assess whether such a test should be used in daily practice. With the example of the value of B-type natriuretic peptides (BNP) in the diagnostic assessment of suspected heart failure, we will discuss the major methodological issues crucial in diagnostic research; most notably the choice of the study population and the data analysis with a multivariable approach. BNP have been studied extensively in the emergency care setting, and also several studies in the primary care are available. The usefulness of this test when applied in combination with other readily available tests is still not adequately addressed in the relevant patient domain, i.e. those who are clinically suspected of heart failure by their GP. Future diagnostic research in primary care should be targeted much more at answering the clinically relevant question 'Is it useful to add this (new) test to the other tests I usually perform, including history taking and physical examination, in patients I suspect of having a certain disease'.

  1. Incremental Value of Increasing Number of Arterial Grafts: The Effect of Diabetes Mellitus.

    Science.gov (United States)

    Schwann, Thomas A; El Hage Sleiman, Abdul Karim M; Yammine, Maroun B; Tranbaugh, Robert F; Engoren, Milo; Bonnell, Mark R; Habib, Robert H

    2018-06-01

    Multiarterial coronary grafting with two arterial grafts leads to improved survival compared with conventional single artery based on left internal thoracic artery to left anterior descending artery and saphenous vein grafts. We investigated whether extending arterial grafting to three or more arterial grafts further improves survival, and whether such a benefit is modified by diabetes mellitus. We analyzed 15-year coronary artery bypass graft surgery mortality data in 11,931 patients (age 64.3 ± 10.5 years; 3,484 women [29.2%]; 4,377 [36.7%] with diabetes mellitus) derived from three US institutions (1994 to 2011). All underwent primary isolated left internal thoracic artery to left anterior descending artery grafting with at least two grafts: one artery (n = 6,782; 56.9%); two arteries (n = 3,678; 30.8%); or three or more arteries (n = 1,471; 12.3%). Long-term survival was estimated by Kaplan-Meier methods. Propensity score matching and comprehensive covariate adjustment (Cox regression) were used to derive long-term risk-adjusted hazard ratio (HR) with 95% confidence interval (CI) for increasing number of arterial grafts in the overall cohort and for diabetes and no-diabetes cohorts. Radial artery (94%) and right internal thoracic artery (6%) were used as additional arterial grafts. Multivariate analysis in all patients showed that diabetes was associated with decreased survival (HR 1.43, 95% CI: 1.34 to 53), whereas increasing number of arterial grafts was associated with decreased mortality (one artery HR 1.0 [reference]; two arteries HR 0.87, 95% CI: 0.80 to 0.95; and three arteries HR 0.83, 95% CI: 0.72 to 0.95). Pairwise comparisons also showed an incremental benefit of additional arterial grafts: two arteries versus one artery, HR 0.89 (95% CI: 0.80 to 0.98); and three arteries versus one artery, HR 0.80 (95% CI: 0.68 to 0.94). A three-artery versus two-artery survival advantage trend was also noted, but was not significant in either the overall study

  2. Cost analysis of the Hemodialysis Reliable Outflow (HeRO) Graft compared to the tunneled dialysis catheter.

    Science.gov (United States)

    Al Shakarchi, Julien; Inston, Nicholas; Jones, Robert G; Maclaine, Grant; Hollinworth, David

    2016-04-01

    In end-stage renal disease patients with central venous obstruction, who have limited vascular access options, the Hemodialysis Reliable Outflow (HeRO) Graft is a new alternative with a lower incidence of complications and longer effective device life compared to tunneled dialysis catheters (TDCs). We undertook an economic analysis of introducing the HeRO Graft in the UK. A 1-year cost-consequence decision analytic model was developed comparing management with the HeRO Graft to TDCs from the perspective of the National Health Service in England. The model comprises four 3-month cycles during which the vascular access option either remains functional for hemodialysis or fails, patients can experience access-related infection and device thrombosis, and they can also accrue associated costs. Clinical input data were sourced from published studies and unit cost data from National Health Service 2014-15 Reference Costs. In the base case, a 100-patient cohort managed with the HeRO Graft experienced 6 fewer failed devices, 53 fewer access-related infections, and 67 fewer device thromboses compared to patients managed with TDCs. Although the initial device and placement costs for the HeRO Graft are greater than those for TDCs, savings from the lower incidence of device complications and longer effective device patency reduces these costs. Overall net annual costs are £2600 for each HeRO Graft-managed patient compared to TDC-managed patients. If the National Health Service were to reimburse hemodialysis at a uniform rate regardless of the type of vascular access, net 1-year savings of £1200 per patient are estimated for individuals managed with the HeRO Graft. The base case results showed a marginal net positive cost associated with vascular access with the HeRO Graft compared with TDCs for the incremental clinical benefit of reductions in patency failures, device-related thrombosis, and access-related infection events in a patient population with limited options for

  3. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  4. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  5. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  6. Use of autologous bone graft in anterior cervical decompression: morbidity & quality of life analysis.

    LENUS (Irish Health Repository)

    Heneghan, Helen M

    2009-01-01

    BACKGROUND: Autologous iliac crest graft has long been the gold standard graft material used in cervical fusion. However its harvest has significant associated morbidity, including protracted postoperative pain scores at the harvest site. Thus its continued practice warrants scrutiny, particularly now that alternatives are available. Our aims were to assess incidence and nature of complications associated with iliac crest harvest when performed in the setting of Anterior Cervical Decompression (ACD). Also, to perform a comparative analysis of patient satisfaction and quality of life scores after ACD surgeries, when performed with and without iliac graft harvest. METHODS: All patients who underwent consecutive ACD procedures, with and without the use of autologous iliac crest graft, over a 48 month period were included (n = 53). Patients were assessed clinically at a minimum of 12 months postoperatively and administered 2 validated quality of life questionnaires: the SF-36 and Cervical Spine Outcomes Questionnaires (Response rate 96%). Primary composite endpoints included incidence of bone graft donor site morbidity, pain scores, operative duration, and quality of life scores. RESULTS: Patients who underwent iliac graft harvest experienced significant peri-operative donor site specific morbidity, including a high incidence of pain at the iliac crest (90%), iliac wound infection (7%), a jejunal perforation, and longer operative duration (285 minutes vs. 238 minutes, p = 0.026). Longer term follow-up demonstrated protracted postoperative pain at the harvest site and significantly lower mental health scores on both quality of life instruments, for those patients who underwent autologous graft harvest CONCLUSION: ACD with iliac crest graft harvest is associated with significant iliac crest donor site morbidity and lower quality of life at greater than 12 months post operatively. This is now avoidable by using alternatives to autologous bone without compromising clinical

  7. Multiple arterial grafts in coronary artery bypass grafting, Sohag University Hospital's initial experience

    Directory of Open Access Journals (Sweden)

    A.A.A. Elsayed

    2017-12-01

    Conclusions: Using multiple arterial grafts did not add a significant risk or time to the classic CABG. With accumulating evidence about better patency rate in arterial grafts, MAR is recommended especially in younger patients undergoing CABG.

  8. Predictors of the success and failure of emergency pelvic artery embolisation for primary postpartum haemorrhage: a 12-year review.

    Science.gov (United States)

    Lai, Billy Ming Hei; Shum, John Sing Fai; Chu, Chi Yeung; Lo, Sherwin Shing Wai; Lau, Kam Ying

    2017-05-01

    This study aimed to identify predictors of the outcome and clinical efficacy of emergency pelvic artery embolisation (PAE) for primary postpartum haemorrhage (PPH) and to assess the post-embolisation fertility of PAE patients in a regional hospital setting. A 12-year retrospective study of patients undergoing emergency PAE was conducted at a regional acute general hospital. Clinical and procedural parameters, clinical outcomes and post-embolisation pregnancy success rates were analysed. There were 47,221 deliveries at the hospital during the study period, of which 33 patients required urgent PAE for primary PPH. The technical success rate of embolisation was 97.0% (n = 32). Clinically adequate haemostasis was achieved by a single embolisation procedure in 24 (72.7%) patients; the remaining eight eventually required surgery to achieve cessation of bleeding. Among the parameters studied, multivariate logistic regression analysis showed that pre-embolisation platelet count (p = 0.036) and maternal age (p = 0.019) were the only significant independent predictors of embolisation failure. Only two patients successfully conceived after PAE, although one of them had an ectopic pregnancy. Emergency PAE is an effective measure to arrest life-threatening bleeding in patients with primary PPH. As low pre-embolisation platelet count and advanced maternal age are associated with higher odds of embolisation failure, careful post-embolisation monitoring may be required for such patients. Embolisation also allows subsequent pregnancy. However, further studies are required to assess the outcomes of post-embolisation pregnancies. Copyright: © Singapore Medical Association

  9. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Charles Y., E-mail: charles.kim@duke.edu; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P. [Duke University Medical Center, Division of Vascular and Interventional Radiology (United States)

    2012-08-15

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  10. Outcomes of Prosthetic Hemodialysis Grafts after Deployment of Bare Metal versus Covered Stents at the Venous Anastomosis

    International Nuclear Information System (INIS)

    Kim, Charles Y.; Tandberg, Daniel J.; Rosenberg, Michael D.; Miller, Michael J.; Suhocki, Paul V.; Smith, Tony P.

    2012-01-01

    Purpose: To compare postintervention patency rates after deployment of bare metal versus covered stents across the venous anastomosis of prosthetic arteriovenous (AV) grafts. Methods: Review of our procedural database over a 6 year period revealed 377 procedures involving stent deployment in an AV access circuit. After applying strict inclusion criteria, our study group consisted of 61 stent deployments in 58 patients (median age 58 years, 25 men, 33 women) across the venous anastomosis of an upper extremity AV graft circuit that had never been previously stented. Both patent and thrombosed AV access circuits were retrospectively analyzed. Within the bare metal stent group, 20 of 32 AV grafts were thrombosed at initial presentation compared to 18 of 29 AV grafts in the covered stent group. Results: Thirty-two bare metal stents and 29 covered stents were deployed across the venous anastomosis. The 3, 6, and 12 months primary access patency rates for bare metal stents were not significantly different than for covered stents: 50, 41, and 22 % compared to 59, 52, and 29 %, respectively (p = 0.21). The secondary patency rates were also not significantly different: 78, 78, and 68 % for bare metal stents compared to 76, 69, and 61 % for covered stents, respectively (p = 0.85). However, covered stents demonstrated a higher primary stent patency rate than bare metal stents: 100, 85, and 70 % compared to 75, 67, and 49 % at 3, 6, and 12 months (p < 0.01). Conclusion: The primary and secondary access patency rates after deployment of bare metal versus covered stents at the venous anastomosis were not significantly different. However, bare metal stents developed in-stent stenoses significantly sooner.

  11. Radiation-induced grafting from binary mixture of monomers onto cellulose acetate film and the characterization of the graft copolymer

    International Nuclear Information System (INIS)

    Bhattacharyya, S.N.; Maldas, D.

    1984-01-01

    Binary mixtures of styrene and acrylamide in methanol-water were grafted onto cellulose acetate films by taking recourse to preirradiation grafting technique. The extent of total grafting was determined from the measured weight increase. The percent acrylamide residue in the graft copolymer was calculated from the observed nitrogen content but the polystyrene residue in the grafted sample was determined by IR spectral studies. When the specific permeability of water vapour through the grafted films is measured, it is observed that the specific permeability increases with the increase of grafting of acrylamide in all humidities, but in case of styrene which is a nonpolar molecule the permeability is found to show a reversed order. In the case of mixed graft the permeability pattern pertains to that when both styrene and acrylamide have their effective roles to play. (author)

  12. Comparison of mesencephalic free-floating tissue culture grafts and cell suspension grafts in the 6-hydroxydopamine-lesioned rat

    DEFF Research Database (Denmark)

    Meyer, Morten; Widmer, H R; Wagner, B

    1998-01-01

    of grafted dopaminergic neurons and to correlate that with the behavioral effects. Additional cultures and acutely prepared explants were also fixed and stored for histological investigation in order to estimate the loss of dopaminergic neurons in culture and after transplantation. Similar behavioral...... numbers of TH-immunoreactive (TH-ir) neurons in grafts of cultured tissue (775 +/- 98, mean +/- SEM) and grafts of fresh, dissociated cell suspension (806 +/- 105, mean +/- SEM). Cell counts in fresh explants, 7-day-old cultures, and grafted cultures revealed a 68.2% loss of TH-ir cells 7 days after......Ventral mesencephalon (VM) of fetal rat and human origin grown as free-floating roller-tube (FFRT) cultures can survive subsequent grafting to the adult rat striatum. To further explore the functional efficacy of such grafts, embryonic day 13 ventral mesencephalic tissue was grafted either after 7...

  13. Validity of exploration for suitable vessels for replantation in the distal fingertip amputation in early childhood: replantation or composite graft.

    Science.gov (United States)

    Imaizumi, Atsushi; Ishida, Kunihiro; Arashiro, Ken; Nishizeki, Osamu

    2013-09-01

    Composite grafting, grafting without microvascular anastomoses, has been widely performed for distal fingertip amputation in children with variable results, whereas successful replantation of these amputations using microsurgical technique has been reported. However, most of these reports included a wide age-range and a mix of different amputation levels. This study reviewed our cases of paediatric digital amputation, in order to verify the value of distal fingertip replantation over composite grafting, especially in early childhood. Seventeen young children (aged 3 years and 8 months on average), with single-digit fingertip amputations in Tamai zone I were reviewed from 1993-2008. Each amputation was subdivided into three types: distal, middle, and proximal. There were three distal, 13 middle, and one proximal type zone I amputations. All were crush or avulsion injuries. All three distal-type cases were reattached as primary composite grafts with one success. For middle-type cases, the survival rate of primary composite graft without exploration for possible vessels for anastomosis was 57%. On exploration, suitable vessels for anastomosis were found 50% of the time, in which all replantations were succeeded. The remaining cases were reattached as secondary composite grafts, with one success using the pocket method. Consequently, the success rate after exploration was 67%. The only one proximal-type amputation was failed in replantation. For the middle-type zone I amputation in early childhood, replantation has a high success rate if suitable vessels can be found. Therefore, exploration is recommended for amputations at this level with a view to replantation, irrespective of the mechanism of injury.

  14. Radiation grafting on natural films

    International Nuclear Information System (INIS)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37–40 N mm −1 ) and puncture deformation (PD=6.5–9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282–296 N mm −1 and PD of 5.0–5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films. - Highlights: • Irradiation of zein

  15. Preparation of poly(vinylbenzyl chloride)-grafted PFA film by a simultaneous irradiation grafting method

    International Nuclear Information System (INIS)

    Fei, Geng; Shin, Jun Hwa; Nho, Young Chang; Lee, Youn Sik

    2009-01-01

    In this study, PFA-g-PVBC films were prepared by a radiation grafting of vinylbenzyl chloride (VBC) monomer onto poly(tetrafluoroethylene-co-perfluoro propyl vinyl ether) (PFA) films by simultaneous irradiation method. IR, TGA, and SEM-EDX instruments were utilized to confirm the successful preparation of the grafted film. The effects of several irradiation conditions, including the dose, VBC concentration, and film thickness on the degree of grafting of PFA-g-PVBC film were investigated

  16. Rib Bone Graft Adjusted to Fit the Facial Asymmetry: A Frame Structure Graft.

    Science.gov (United States)

    Lee, Yoon Ho; Choi, Jong Hwan; Hwang, Kun; Choi, Jun Ho

    2015-10-01

    The authors introduce the concept of a "frame structure graft" in which a harvested rib bone was adjusted to fit facial asymmetry. On the costochondral junction of the sixth or seventh rib, a 5 cm incision was made. Through a subperiosteal dissection, the rib bone was harvested. Using a reciprocating saw, the harvested rib was scored on its anterior surface as well as its posterior surface with a partial depth at different intervals. The harvested rib bone was placed on the skin surface of the unaffected side of the face and a curvature was created exactly matching that of the unaffected side by bending the bone using a greenstick fracture. Thereafter, the graft was adjusted to conceal the asymmetry of the deficient side. The adjusted "frame structure" was transferred to the defect through the incisions on the affected side, and the "frame structure" graft was placed on the mandible or zygoma. The graft fixation was done externally with at least 2 Kirschner wires (K-wires). From January 2005 to August 2013, a total of 30 patients (13 men, 17 women, mean age 25.6 years) received a frame structure graft. All 30 patients achieved good healing at the operation site without complications. Donor-site morbidity as pneumothorax from the rib bone harvest was not found. Merits of this frame structure graft, the authors think, are that this method could allow a similar curvature to the normal side. In addition, the procedure itself is easy.

  17. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    International Nuclear Information System (INIS)

    El-Salmawi, K.M.; El-Naggar, A.M.; Said, H.M.; Zahran, A.H.

    1996-01-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr's salt), solvent composition (MeOH and H 2 O), radiation dose and dose rate were considered. It was found that the role of Mohr's salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr's salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H 2 O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs

  18. Imaging features of anterior cruciate ligament reconstruction graft insufficiency

    International Nuclear Information System (INIS)

    Shang Yao; Zhang Yue; Tian Chunyan; Zheng Zhuozhao

    2011-01-01

    Objective: To investigate the imaging features of anterior cruciate ligament (ACL) graft insufficiency. Methods: X-Ray and MR imaging examinations in 24 consecutive patients who had ACL reconstructive graft insufficiency were retrospectively evaluated for tunnel position, osteoarthrosis and its related complications. Follow-up arthroscopy showed 16 graft tears and 8 graft laxities. Fisher exact test was used to compare tunnel malpositions, the proportion of graft tear on MRI and osteoarthrosis between graft tear group and graft laxity group. Results: Two malpositions of tibial tunnel and 3 malpositions of femoral tunnel were seen in graft tear group. Three-malpositions of tibial tunnel and 4 malpositions of femoral tunnel were seen in graft laxity group. The proportion of tibial or femoral malposition showed no significant difference between the two groups (P=0.289, P=0.167). In graft tear group, 15 complete graft tears were diagnosed correctly, 1 partial tear was misdiagnosed as normal on MRI. In graft laxity group, 4 grafts were diagnosed as normal and 4 were considered as graft tear on MRI. A significant difference was seen between the two groups (P=0.028) in the proportion of graft tear diagnosed on MRI. Fourteen osteoarthrosis were seen in graft tear group and 5 in graft laxity group. No significant difference was seen between the two groups (P= 0.289) in the proportion of osteoarthrosis. Conclusion: The proportions of tunnel malposition and osteoarthrosis showed no significant difference between the graft tear group and graft Laxity group. Most graft tears can be diagnosed accurately on MRI, but some cases of graft laxity may be misdiagnosed for graft tear. (authors)

  19. Access to Heart Transplantation: A Proper Analysis of the Competing Risks of Death and Transplantation Is Required to Optimize Graft Allocation

    Directory of Open Access Journals (Sweden)

    Christelle Cantrelle, MS

    2017-08-01

    Conclusions. The heart allocation system strongly modifies the risk of pretransplant mortality related to heart failure severity. An in-depth competing risk analysis is therefore a more appropriate method to evaluate graft allocation systems. This knowledge should help to prioritize candidates in the context of a limited donor pool.

  20. Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

    International Nuclear Information System (INIS)

    Das, Neelan; Bratby, Mark J.; Shrivastava, Vivek; Cornall, Alison J.; Darby, Christopher R.; Boardman, Philip; Anthony, Susan; Uberoi, Raman

    2011-01-01

    Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa ® , Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4–270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

  1. Allogeneic hematopoietic stem cell transplantation in children with primary immunodeficiencies: Hospital Israelita Albert Einstein experience.

    Science.gov (United States)

    Fernandes, Juliana Folloni; Kerbauy, Fabio Rodrigues; Ribeiro, Andreza Alice Feitosa; Kutner, Jose Mauro; Camargo, Luis Fernando Aranha; Stape, Adalberto; Troster, Eduardo Juan; Zamperlini-Netto, Gabriele; Azambuja, Alessandra Milani Prandini de; Carvalho, Bruna; Dorna, Mayra de Barros; Vilela, Marluce Dos Santos; Jacob, Cristina Miuki Abe; Costa-Carvalho, Beatriz Tavares; Cunha, Jose Marcos; Carneiro-Sampaio, Magda Maria; Hamerschlak, Nelson

    2011-06-01

    To report the experience of a tertiary care hospital with allogeneic hematopoietic stem cell transplantation in children with primary immunodeficiencies. Seven pediatric patients with primary immunodeficiencies (severe combined immunodeficiency: n = 2; combined immunodeficiency: n = 1; chronic granulomatous disease: n = 1; hyper-IgM syndrome: n = 2; and IPEX syndrome: n = 1) who underwent eight hematopoietic stem cell transplants in a single center, from 2007 to 2010, were studied. Two patients received transplants from HLA-identical siblings; the other six transplants were done with unrelated donors (bone marrow: n = 1; cord blood: n = 5). All patients had pre-existing infections before hematopoietic stem cell transplants. One patient received only anti-thymocyte globulin prior to transplant, three transplants were done with reduced intensity conditioning regimens and four transplants were done after myeloablative therapy. Two patients were not evaluated for engraftment due to early death. Three patients engrafted, two had primary graft failure and one received a second transplant with posterior engraftment. Two patients died of regimen related toxicity (hepatic sinusoidal obstruction syndrome); one patient died of progressive respiratory failure due to Parainfluenza infection present prior to transplant. Four patients are alive and well from 60 days to 14 months after transplant. Patients' status prior to transplant is the most important risk factor on the outcome of hematopoietic stem cell transplants in the treatment of these diseases. Early diagnosis and the possibility of a faster referral of these patients for treatment in reference centers may substantially improve their survival and quality of life.

  2. Inheritance of graft compatibility in Douglas fir.

    Science.gov (United States)

    D.L. Copes

    1973-01-01

    Graft compatibility of genetically related and unrelated rootstock-scion combinations was compared. Scion clones were 75% compatible when grafted on half-related rootstocks but only 56% compatible when grafted on unrelated rootstocks. Most variance associated with graft incompatibility in Douglas-fir appears to be caused by multiple genes.

  3. Assessment of Novel Anti-thrombotic Fusion Proteins for Inhibition of Stenosis in a Porcine Model of Arteriovenous Graft.

    Directory of Open Access Journals (Sweden)

    Christi M Terry

    Full Text Available Hemodialysis arteriovenous synthetic grafts (AVG provide high volumetric blood flow rates shortly after surgical placement. However, stenosis often develops at the vein-graft anastomosis contributing to thrombosis and early graft failure. Two novel fusion proteins, ANV-6L15 and TAP-ANV, inhibit the tissue factor/factor VIIa coagulation complex and the factor Xa/factor Va complex, respectively. Each inhibitor domain is fused to an annexin V domain that targets the inhibitor activity to sites of vascular injury to locally inhibit thrombosis. This study's objective was to determine if these antithrombotic proteins are safe and effective in inhibiting AVG stenosis.A bolus of either TAP-ANV or ANV-6L15 fusion protein was administered intravenously immediately prior to surgical placement of a synthetic graft between the external jugular vein and common carotid artery in a porcine model. At surgery, the vein and artery were irrigated with the anti-thrombotic fusion protein. Control animals received intravenous heparin. At 4 weeks, MRI was performed to evaluate graft patency, the pigs were then euthanized and grafts and attached vessels were explanted for histomorphometric assessment of neointimal hyperplasia at the vein-graft anastomosis. Blood was collected at surgery, immediately after surgery and at euthanasia for serum metabolic panels and coagulation chemistries.No acute thrombosis occurred in the control group or in either experimental group. No abnormal serum chemistries, activated clotting times or PT, PTT values were observed after treatment in experimental or control animals. However, at the vein-graft anastomosis, there was no difference between the control and experimental groups in cross-sectional lumen areas, as measured on MRI, and no difference in hyperplasia areas as determined by histomorphometry. These results suggest that local irrigation of TAP-ANV or ANV-6L15 intra-operatively was as effective in inhibiting acute graft thrombosis

  4. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  5. Radiation-induced grafting of acrylamide onto guar gum in aqueous medium: Synthesis and characterization of grafted polymer guar-g-acrylamide

    Energy Technology Data Exchange (ETDEWEB)

    Biswal, Jayashree [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Kumar, Virendra [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Bhardwaj, Y.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)]. E-mail: ykbhard@magnum.barc.ernet.in; Goel, N.K. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Dubey, K.A. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Chaudhari, C.V. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Sabharwal, S. [Radiation Technology Development Section, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2007-10-15

    Mutual radiation grafting technique has been applied to carry out grafting of acrylamide (AAm) onto guar gum (GG) using high-energy Co{sup 60} {gamma} radiation to enhance its flocculating properties for industrial effluents. The grafted product was characterized using analytical probes like elemental analysis, thermal analysis, Fourier transformed infrared (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). The grafting extent was observed to decrease with the dose rate and increase with the concentration of AAm. Thermo gravimetric analysis (TGA) of grafted and ungrafted samples indicated better stability of grafted product. {gamma} and microwave radiation effect on grafted and virgin GG has also been reported.

  6. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  7. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  8. Preliminary failure mode and effect analysis

    International Nuclear Information System (INIS)

    Addison, J.V.

    1972-01-01

    A preliminary Failure Mode and Effect Analysis (FMEA) was made on the overall 5 Kwe system. A general discussion of the system and failure effect is given in addition to the tabulated FMEA and a primary block diagram of the system. (U.S.)

  9. Survival of dental implants in native and grafted bone in irradiated head and neck cancer patients: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Aravind Buddula

    2011-01-01

    Full Text Available Aim: To study the long-term survival of dental implants placed in native or grafted bone in irradiated bone in subjects who had received radiation for head and neck cancer. Materials and Methods: A retrospective chart review was conducted for all patients who received dental implants following radiation treatment for head and neck cancer between May 1, 1987 and July 1, 2008. Only patients irradiated with a radiation dose of 50 Gy or greater and those who received dental implants in the irradiated field after head and neck radiation were included in the study. The associations between implant survival and patient/implant characteristics were estimated by fitting univariate marginal Cox proportional hazards models. Results: A total of 48 patients who had prior head and neck radiation had 271 dental implants placed during May 1987-July 2008. There was no statistically significant difference between implant failure in native and grafted bone (P=0.76. Survival of implants in grafted bone was 82.3% and 98.1% in maxilla and mandible, respectively, after 3 years. Survival of implants in native bone in maxilla and mandible was 79.8% and 100%, respectively, after 3 years. For implants placed in the native bone, there was a higher likelihood of failure in the maxilla compared to the mandible and there was also a tendency for implants placed in the posterior region to fail compared to those placed in the anterior region. Conclusion: There was no significant difference in survival when implants were placed in native or grafted bone in irradiated head and neck cancer patients. For implants placed in native bone, survival was significantly influenced by the location of the implant (maxilla or mandible, anterior or posterior.

  10. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Salmawi, K M; El-Naggar, A M; Said, H M; Zahran, A H [Radiation Chemistry Department, National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr`s salt), solvent composition (MeOH and H{sub 2} O), radiation dose and dose rate were considered. It was found that the role of Mohr`s salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr`s salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H{sub 2} O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs.

  11. Dynamics of bone graft healing around implants

    Directory of Open Access Journals (Sweden)

    Narayan Venkataraman

    2015-01-01

    A few questions arise pertaining to the use of bone grafts along with implants are whether these are successful in approximation with implant. Do they accelerate bone regeneration? Are all defects ultimately regenerated with new viable bone? Is the bone graft completely resorbed or integrated in new bone? Does the implant surface characteristic positively affect osseointegration when used with a bone graft? What type of graft and implant surface can be used that will have a positive effect on the healing type and time? Finally, what are the dynamics of bone graft healing around an implant? This review discusses the cellular and molecular mechanisms of bone graft healing in general and in vicinity of another foreign, avascular body, namely the implant surface, and further, the role of bone grafts in osseointegration and/or clinical success of the implants.

  12. Handling of the bone long pseudoarthrosis with autologo structural bone graft in failure osteosynthesis

    International Nuclear Information System (INIS)

    Satizabal Azuero, Carlos; Calderon Uribe, Oscar; Alban P, Paulo Antonio; Gamba Sanchez, Cesar Enrique

    2003-01-01

    We find in the literature that the usual way to treat pseudoarthrosis always includes the removal of the material used to stabilize the fractures, with bring along high hospital and social costs for the patient and the family. The treatment we purpose is the appliance of an autologo structural iliac bone graft, trapezoid form, throughout a minimal incision into the lesion. We treated 12 patients that included 14 long bones in a two year period, age range of 23,2 y 12 (86%) patients with femur pseudoarthrosis, 1 (7%) with tibia y 1 (7%) humerus. we obtained 100% consolidation at 5 months after surgery. no complications reported from the patients, and an important reduce in hospital and social costs

  13. Hemodynamic effects of spiral ePTFE prosthesis compared with standard arteriovenous graft in a carotid to jugular vein porcine model.

    Science.gov (United States)

    Jahrome, Ommid K; Hoefer, Imo; Houston, Graeme J; Stonebridge, Peter A; Blankestijn, Peter J; Moll, Frans L; de Borst, Gert J

    2011-01-01

    The primary patency rate of arteriovenous (AV) grafts is limited by distal venous anastomosis stenosis or occlusion due to intimal hyperplasia associated with distal graft turbulence. The normal blood flow in native arteries is spiral laminar flow. Standard vascular grafts do not produce spiral laminar flow at the distal anastomosis. Vascular grafts which induce a spiral laminar flow distally result in lower turbulence, particularly near the vessel wall. This initial study compares the hemodynamic effects of a spiral flow-inducing graft and a standard graft in a new AV carotid to jugular vein crossover graft porcine model. Four spiral flow grafts and 4 control grafts were implanted from the carotid artery to the contralateral jugular vein in 4 pigs. Two animals were terminated after 48 hours and 2 at 14 days. Graft patency was assessed by selective catheter digital angiography, and the flow pattern was assessed by intraoperative flow probe and color Doppler ultrasound (CDU) measurements. The spiral grafts were also assessed at enhanced flow rates using an external roller pump to simulate increased flow rates that may occur during dialysis using a standard dialysis needle cannulation. The method increased the flow rate through the graft by 660 ml/min. The graft distal anastomotic appearances were evaluated by explant histopathology. All grafts were patent at explantation with no complications. All anastomoses were found to be wide open and showed no significant angiographic stenosis at the distal anastomosis in both spiral and control grafts. CDU examinations showed a spiral flow pattern in the spiral graft and double helix pattern in the control graft. No gross histopathological effects were seen in either spiral or control grafts. This porcine model is robust and allows hemodynamic flow assessment up to 14 days postimplantation. The spiral flow-inducing grafts produced and maintained spiral flow at baseline and enhanced flow rates during dialysis needle

  14. Oxidative stress in primary glomerular diseases

    DEFF Research Database (Denmark)

    Markan, Suchita; Kohli, Harbir Singh; Sud, Kamal

    2008-01-01

    To evaluate the status of oxidative stress in patients with different primary glomerular diseases (PGD) which have differential predisposition to renal failure.......To evaluate the status of oxidative stress in patients with different primary glomerular diseases (PGD) which have differential predisposition to renal failure....

  15. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  16. Tuning the Mechanical Properties of Polymer Nanocomposites Filled with Grafted Nanoparticles by Varying the Grafted Chain Length and Flexibility

    Directory of Open Access Journals (Sweden)

    Zixuan Wang

    2016-08-01

    Full Text Available By employing coarse-grained molecular dynamics simulation, we simulate the spatial organization of the polymer-grafted nanoparticles (NPs in homopolymer matrix and the resulting mechanical performance, by particularly regulating the grafted chain length and flexibility. The morphologies ranging from the agglomerate, cylinder, sheet, and string to full dispersion are observed, by gradually increasing the grafted chain length. The radial distribution function and the total interaction energy between NPs are calculated. Meanwhile, the stress–strain behavior of each morphology and the morphological evolution during the uniaxial tension are simulated. In particular, the sheet structure exhibits the best mechanical reinforcement compared to other morphologies. In addition, the change of the grafted chain flexibility to semi-flexibility leads to the variation of the morphology. We also find that at long grafted chain length, the stress–strain behavior of the system with the semi-flexible grafted chain begins to exceed that of the system with the flexible grafted chain, attributed to the physical inter-locking interaction between the matrix and grafted polymer chains. A similar transition trend is as well found in the presence of the interfacial chemical couplings between grafted and matrix polymer chains. In general, this work is expected to help to design and fabricate high performance polymer nanocomposites filled with grafted NPs with excellent and controllable mechanical properties.

  17. Type D personality is a predictor of poor emotional quality of life in primary care heart failure patients independent of depressive symptoms and New York Heart Association functional class.

    Science.gov (United States)

    Pedersen, Susanne S; Herrmann-Lingen, Christoph; de Jonge, Peter; Scherer, Martin

    2010-02-01

    Quality of life is an important patient-centered outcome and predictor of mortality in heart failure, but little is known about the role of personality as a determinant of quality of life in this patient group. We examined the influence of Type D personality (i.e., increased negative emotions paired with emotional non-expression) on quality of life in primary care heart failure patients, using a prospective study design. Heart failure patients (n = 251) recruited from 44 primary care practices in Germany completed standardized questionnaires at baseline and 9 months. The prevalence of Type D was 31.9%. Type D patients experienced poorer emotional (P emotional (P = .78) nor physical quality of life (P = .74) over time; neither the interaction for time by Type D for emotional (P = .31) nor physical quality of life (P = .91) was significant, indicating that Type D exerted a stable effect on quality of life over time. Adjusting for demographics, New York Heart Association functional class, and depressive symptoms, Type D remained an independent determinant of emotional (P = .03) but not physical quality of life (P = .29). Primary care heart failure patients with a Type D personality experienced poorer emotional but not physical quality of life compared to non-Type D patients. Patients with this personality profile should be identified in primary care to see if their treatment is optimal, as both Type D and poor quality of life have been associated with increased morbidity and mortality.

  18. The effects of hydroxyapatite coating and bone allograft on fixation of loaded experimental primary and revision implants.

    Science.gov (United States)

    Søballe, Kjeld; Mouzin, Olivier R G; Kidder, Louis A; Overgaard, Søren; Bechtold, Joan E

    2003-06-01

    We used our established experimental model of revision joint replacement to examine the roles of hydroxyapatite coating and bone graft in improving the fixation of revision implants. The revision protocol uses the Søballe micromotion device in a preliminary 8-week period of implant instability for the presence of particulate polyethylene. During this procedure, a sclerotic endosteal bone rim forms, and a dense fibrous membrane is engendered, having macrophages with ingested polyethylene and high levels of inflammatory cytokines. At the time of revision after 8 weeks, the cavity is revised with either a titanium alloy (Ti) or a hydroxyapatite (HA) 6.0 mm plasma-sprayed implant, in the presence or absence of allograft packed into the initial 0.75 mm peri-implant gap. The contralateral limb is subjected to primary surgery with the same implant configuration, and serves as control. 8 implants were included in each of the 8 treatment groups (total 64 implants in 32 dogs). The observation period was 4 weeks after revision. Outcome measures are based on histomorphometry and mechanical pushout properties. The revision setting was always inferior to its primary counterpart. Bone graft improved the revision fixation in all treatment groups, as also did the HA coating. The sole exception was revision-grafted HA implants, which reached the same fixation as primary Ti and HA grafted implants. The revision, which was less active in general, seems to need the dual stimulation of bone graft and HA implant surface, to obtain the same level of fixation associated with primary implants. Our findings suggest that the combination of HA implant and bone graft may be of benefit in the clinical revision implant setting.

  19. Islet transplantation as safe and efficacious method to restore glycemic control and to avoid severe hypoglycemia after donor organ failure in pancreas transplantation.

    Science.gov (United States)

    Gerber, Philipp A; Hochuli, Michel; Benediktsdottir, Bara D; Zuellig, Richard A; Tschopp, Oliver; Glenck, Michael; de Rougemont, Olivier; Oberkofler, Christian; Spinas, Giatgen A; Lehmann, Roger

    2018-01-01

    The aim of this study was to assess safety and efficacy of islet transplantation after initial pancreas transplantation with subsequent organ failure. Patients undergoing islet transplantation at our institution after pancreas organ failure were compared to a control group of patients with pancreas graft failure, but without islet transplantation and to a group receiving pancreas retransplantation. Ten patients underwent islet transplantation after initial pancreas transplantation failed and were followed for a median of 51 months. The primary end point of HbA1c islet transplantation and in all three patients in the pancreas retransplantation group, but by none of the patients in the group without retransplantation (n = 7). Insulin requirement was reduced by 50% after islet transplantation. Kidney function (eGFR) declined with a rate of -1.0 mL ± 1.2 mL/min/1.73 m 2 per year during follow-up after islet transplantation, which tended to be slower than in the group without retransplantation (P = .07). Islet transplantation after deceased donor pancreas transplant failure is a method that can safely improve glycemic control and reduce the incidence of severe hypoglycemia and thus establish similar glycemic control as after initial pancreas transplantation, despite the need of additional exogenous insulin. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Physical properties of agave cellulose graft polymethyl methacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan [Polymer Research Centre (PORCE), School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi Selangor (Malaysia)

    2013-11-27

    The grafting polymerization of methyl methacrylate and Agave cellulose was prepared and their structural analysis and morphology were investigated. The grafting reaction was carried out in an aqueous medium using ceric ammonium nitrate as an initiator. The structural analysis of the graft copolymers was carried out by Fourier transform infrared and X-ray diffraction. The graft copolymers were also characterized by field emission scanning electron microscopy (FESEM). An additional peak at 1732 cm{sup −1} which was attributed to the C=O of ester stretching vibration of poly(methyl methacrylate), appeared in the spectrum of grafted Agave cellulose. A slight decrease of crystallinity index upon grafting was found from 0.74 to 0.68 for cellulose and grafted Agave cellulose, respectively. Another evidence of grafting showed in the FESEM observation, where the surface of the grafted cellulose was found to be roughed than the raw one.

  1. [Bone graft reconstruction for posterior mandibular segment using the formwork technique].

    Science.gov (United States)

    Pascual, D; Roig, R; Chossegros, C

    2014-04-01

    Pre-implant bone graft in posterior mandibular segments is difficult because of masticatory and lingual mechanical constraints, because of the limited bone vascularization, and because of the difficulty to cover it with the mucosa. The formwork technique is especially well adapted to this topography. The recipient site is abraded with a drill. Grooves are created to receive and stabilize the grafts. The bone grafts were harvested from the ramus. The thinned cortices are assembled in a formwork and synthesized by mini-plates. The gaps are filled by bone powder collected during bone harvesting. The bone volume reconstructed with the formwork technique allows anchoring implants more than 8mm long. The proximity of the inferior alveolar nerve does not contra indicate this technique. The formwork size and its positioning on the alveolar crest can be adapted to prosthetic requirements by using osteosynthesis plates. The lateral implant walls are supported by the formwork cortices; the implant apex is anchored on the native alveolar crest. The primary stability of implants is high, and the torque is important. The ramus harvesting decreases operative risks. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  2. PRFM enhance wound healing process in skin graft.

    Science.gov (United States)

    Reksodiputro, Mirta; Widodo, Dini; Bashiruddin, Jenny; Siregar, Nurjati; Malik, Safarina

    2014-12-01

    Facial plastic and reconstructive surgery often used skin graft on defects that cannot be covered primarily by a local flap. However, wound healing using skin graft is slow, most of the time the graft is contractured and the take of graft is not optimal. Platelet rich fibrin matrix (PRFM) is a new generation of concentrated platelets that produce natural fibrin and reported to speed up the healing process. Application of PRFM in the skin graft implants is expected to increase the survival of the graft. We used porcine as animal models to elucidate the effect of autologous PRFM on wound healing in full-thickness (FTSG) and split-thickness (STSG) skin grafts. Survival level of the skin graft was determined by using ImageJ software based on the formation of collagen type 1 and graft take. We observed that the use of PRFM in FTSG and STSG increased type 1 collagen formation. We also found that PRFM addition in STSG gave the best skin graft take. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Does fat grafting have any beneficial effects in nerve regeneration?

    Directory of Open Access Journals (Sweden)

    Vlad Bloancă1,

    2016-12-01

    Full Text Available OBJECTIVES The aim of our study was to assess the effect of autologous fat graft on nerve regeneration by creating a suitable experimental model. MATERIALS AND METHODS The rat sciatic nerve was used, followed by transaction. Primary neurorrhaphy was made on both hind legs, but a processed fat graft was applied on one side, surrounding the nerve. RESULTS We used histological examination for the followup, at 4 and 10 weeks. The results showed an increased and a more organised neural regeneration on the side where the fat graft was used. CONCLUSIONS The adipose-derived stem cell has clearly demonstrated its capacity to transdifferentiate. However, its specific role in this process is not yet clearly understood. We attempted to explore the blunt effect of this cell on direct neurrorhaphy. We did not observe a categorical differentiation towards Schwann like cell, but mostly an antifibrotic and antiinflammatory effect. Graphical abstract: Technical aspects of fat grafting on neurorrhaphy. REFERENCES 1. Raposio E, Caruana G, Bonomini S, Libondi G. A novel and effective strategy for the isolation of adipose-derived stem cells: minimally manipulated adipose-derived stem cells for more rapid and safe stem cell therapy. Plast Reconstr Surg. 2014;133:1406-9. 2. Zack-Williams SDL, Butler PE, Kalaskar DM. Current progress in use of adipose derived stem cells in peripheral nerve regeneration. World J Stem Cells. 2015; 7: 51–64. 3. Zuk PA. The Adipose-derived Stem Cell: Looking Back and Looking Ahead. Mol Biol Cell. 2010;21:1783–1787.

  4. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    Science.gov (United States)

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  5. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    International Nuclear Information System (INIS)

    Shawyer, Andrew; Fotiadis, Nicos I.; Namagondlu, Girish; Iyer, Arun; Blunden, Mark; Raftery, Martin; Yaqoob, Magdi

    2013-01-01

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482–0.977] at 6 months and 72.7 % (95 % CI 0.390–0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587–0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156–2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  6. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    Energy Technology Data Exchange (ETDEWEB)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com [Royal Marsden Hospital, Radiology Department, The Royal Marsden NHS Foundation Trust (United Kingdom); Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom); Iyer, Arun, E-mail: arun.iyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Blunden, Mark, E-mail: mark.blunden@bartsandthelondon.nhs.uk; Raftery, Martin, E-mail: martin.raftery@bartsandthelondon.nhs.uk; Yaqoob, Magdi, E-mail: magdi.yaqoob@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom)

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  7. Improvement of polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    1999-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect ultimate performance of polymer product. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method, photoprotector 2-hydroxy-4-(3-methacryloxy-2- hydroxy-propoxy) benzophenone (HMB) has been readily grafted to low density polyethylene (LDPE) in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. The grafted LDPE film in methanol and tetrahydrofuran (containing 1 w/w % of grafted HMB), 1 w/w % blended HMB with LDPE and nongrafted LDPE film, were all exposed to accelerated aging and natural weathering and their spectral changes, expressed by the carbonyl index, were then compared. The change of elongation at break and tensile strength were measured in the course of aging. UV stability tests on aged films and change in mechanical properties indicate a pronounced protective effect achieved by grafted stabilizer. Grafting in methanol solution appears to be an efficient photostabilization treatment and the most economical with respect to the consumption of monomer, the grafting yield being less than 0.5%. Surface grafting is an efficient photostabilization method since grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated. (author)

  8. Revision Vaginoplasty: A Comparison of Surgical Outcomes of Laparoscopic Intestinal versus Perineal Full-Thickness Skin Graft Vaginoplasty.

    Science.gov (United States)

    Van der Sluis, Wouter B; Bouman, Mark-Bram; Buncamper, Marlon E; Mullender, Margriet G; Meijerink, Wilhelmus J

    2016-10-01

    Vaginal (re)construction can greatly improve the quality of life of indicated patients. If primary vaginoplasty fails, multiple surgical approaches exist for revision. The authors compared surgical results of laparoscopic intestinal versus full-thickness skin graft revision vaginoplasty. A retrospective chart review of patients who underwent revision vaginoplasty at the authors' institution was conducted. Patient demographics, surgical characteristics, complications, hospitalization, reoperations, and neovaginal depth for both surgical techniques were recorded and compared. The authors studied a consecutive series of 50 transgender and three biological women who underwent revision vaginoplasty, of which 21 were laparoscopic intestinal and 32 were perineal full-thickness skin graft vaginoplasties, with a median clinical follow-up of 3.2 years (range, 0.5 to 19.7 years). Patient demographics did not differ significantly. There was no mortality. Two intraoperative rectal perforations (10 percent) occurred in the intestinal group versus six (19 percent) in the full-thickness skin graft group. Operative time was shorter for the full-thickness skin graft vaginoplasty group (131 ± 35 minutes versus 191 ± 45 minutes; p skin graft (81 percent) vaginoplasty procedures. A deeper neovagina was achieved with intestinal vaginoplasty (15.9 ± 1.4 cm versus 12.5 ± 2.8 cm; p skin graft vaginoplasty can be used as secondary vaginal reconstruction. Intraoperative and postoperative complications do not differ significantly, but rectal perforation was more prevalent in the full-thickness skin graft vaginoplasty group. Although the operative time of laparoscopic intestinal vaginoplasty is longer, adequate neovaginal depth was more frequently achieved than in secondary perineal full-thickness skin graft vaginoplasty. Therapeutic, III.

  9. Modification of polyetherurethane for biomedical application by radiation induced grafting. II. Water sorption, surface properties, and protein adsorption of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1984-01-01

    A series of polyetherurethane films grafted by means of gamma radiation with hydrophilic or reactive monomers (2-hydroxyethyl methacrylate, 2,3-epoxypropyl methacrylate, 2,3-dihydroxypropyl methacrylate, and acrylamide) and partially chemically modified were subjected to various physico-chemical investigation methods involving water sorption, contact angle, and protein adsorption measurements. From contact angle data the interfacial free energy gamma sw between grafted films and water was calculated. It was found that the water uptake of grafted films increases with grafting yield or, in the case of grafted and afterwards chemically modified films, with reaction yield; the diffusion coefficient of water in the modified films also increases with grafting yield. Contact angle studies revealed all grafted films to have surfaces more hydrophilic than the ungrafted trunk polymer. The degree of hydrophilicity--especially of HEMA-grafted films--strongly depends on grafting conditions. For some grafted samples with high surface hydrophilicity very low interfacial free energies approaching zero were measured. The study of the competitive adsorption of bovine serum albumin, gamma-globulin, and fibrinogen from a synthetic protein solution onto modified films showed that the adsorption of albumin increases markedly with increasing grafting yields, whereas the fibrinogen and gamma-globulin adsorption only slightly increases. A correlation between interfacial free energy and protein adsorption in the sense of the minimum interfacial free energy hypothesis was found only for samples with grafting yields below 5%. At higher grafting yields the increased surface area complicates the analysis

  10. Homogeneous cation exchange membrane by radiation grafting

    International Nuclear Information System (INIS)

    Kolhe, Shailesh M.; G, Agathian; Ashok Kumar

    2001-01-01

    Preparation of a strong cation exchange membrane by radiation grafting of styrene on to polyethylene (LDPE) film by mutual irradiation technique in the presence of air followed by sulfonation is described. The grafting has been carried out in the presence of air and without any additive. Low dose rate has been seen to facilitate the grafting. Further higher the grafting percentage more is the exchange capacity. The addition of a swelling agent during the sulfonation helped in achieving the high exchange capacity. The TGA-MASS analysis confirmed the grafting and the sulfonation. (author)

  11. Nuclear accidents and bone marrow graft

    International Nuclear Information System (INIS)

    Bernard, J.

    1988-01-01

    In case of serious contamination, the only efficacious treatment is the bone marrow grafts. The graft types and conditions have been explained. To restrict the nuclear accidents consequences, it is recommended to: - take osseous medulla of the personnel exposed to radiations and preserve it , that permits to carry out rapidly the auto-graft in case of accidents; - determine, beforehand, the HLA group of the personnel; - to register the voluntary donors names and addresses, and their HLA group, that permits to find easily a compatible donar in case of allo-graft. (author)

  12. Enhancement of the grafting performance and of the water absorption of cassava starch graft copolymer by gamma radiation

    International Nuclear Information System (INIS)

    Kiatkamjornwong, Suda; Meechai, Nispa

    1997-01-01

    Enhancement of the gamma radiation grafting of acrylonitrile onto gelatinized cassava starch was investigated. Infrared spectrometry was used to follow the chemical changes in the grafting reaction and from saponification. The saponified starch-g-PAN (HSPAN) was then characterized in terms of grafting parameters to provide a guide for the optimum total dose (kGy) and the appropriate ratio of starch/acrylonitrile for a fixed dose rate of 2.5 x 10 -1 kGy/min. Other dose rates were also carried out to obtain the appropriate result of grafting copolymerization and of water absorption. A thin aluminium foil, covering the inner wall of the reaction vessel, was found to be far more effective than any other metal films in the enhancement of the grafting reaction and the water absorption as well. Nitric acid in the medium increases the grafting yield and the water absorption. Methyl ether hydroquinone inhibitor was evaluated for its ability to increase homopolymerization and decrease graft reaction. When styrene was used as a comonomer, it hampered the grafting of acrylonitrile onto starch backbone. The water absorption capacity was improved by freeze-drying the HSPAN. The treatment of the HSPAN with aluminium trichloride hexahydrate was found to enhance the degree of wicking, but to decrease the water absorbency. (author)

  13. Hydrogen, a potential safeguard for graft-versus-host disease and graft ischemia-reperfusion injury?

    Science.gov (United States)

    Yuan, Lijuan; Shen, Jianliang

    2016-01-01

    Post-transplant complications such as graft-versus-host disease and graft ischemia-reperfusion injury are crucial challenges in transplantation. Hydrogen can act as a potential antioxidant, playing a preventive role against post-transplant complications in animal models of multiple organ transplantation. Herein, the authors review the current literature regarding the effects of hydrogen on graft ischemia-reperfusion injury and graft-versus-host disease. Existing data on the effects of hydrogen on ischemia-reperfusion injury related to organ transplantation are specifically reviewed and coupled with further suggestions for future work. The reviewed studies showed that hydrogen (inhaled or dissolved in saline) improved the outcomes of organ transplantation by decreasing oxidative stress and inflammation at both the transplanted organ and the systemic levels. In conclusion, a substantial body of experimental evidence suggests that hydrogen can significantly alleviate transplantation-related ischemia-reperfusion injury and have a therapeutic effect on graft-versus-host disease, mainly via inhibition of inflammatory cytokine secretion and reduction of oxidative stress through several underlying mechanisms. Further animal experiments and preliminary human clinical trials will lay the foundation for hydrogen use as a drug in the clinic. PMID:27652837

  14. Comparison of midterm results for the Talent and Endurant stent graft.

    Science.gov (United States)

    't Mannetje, Yannick W; Cuypers, Philippe W M; Saleem, Ben R; Bode, Aron S; Teijink, Joep A W; van Sambeek, Marc R H M

    2017-09-01

    Stent graft evolution is often addressed as a cause for improved outcomes of endovascular aneurysm repair for patients with an abdominal aortic aneurysm. In this study, we directly compared the midterm result of Endurant stent graft with its predecessor, the Talent stent graft (both Medtronic, Santa Rosa, Calif). Patient treated from January 2005 to December 2010 in a single tertiary center in The Netherlands with a Talent or Endurant stent graft were eligible for inclusion. Ruptured abdominal aortic aneurysms or patients with previous aortic surgery were excluded. The primary end point was the Kaplan-Meier estimated freedom from secondary interventions. Secondary end points were perioperative outcomes and indications for secondary interventions. In total, 221 patients were included (131 Endurant and 90 Talent). At baseline, the median aortic bifurcation was narrower for the Endurant (30 mm vs 39 mm; P Talent and Endurant, respectively. The estimated freedom from secondary interventions at 30 days, 1 year, 5 years, and 7 years was 94.3%, 89.4%, 72.2%, and 64.1% for Talent and 96.8%, 89.3%, 75.2%, and 69.2% for Endurant (P = .528). The indication for secondary interventions does differ; more patients required an intervention for a proximal neck-related complication (type Ia endoleak or migration) in the Talent group (18.2% vs 4.8%; P = .001), whereas more interventions for iliac limb stenosis were seen in the Endurant group (0.0% vs 4.8%; P = .044). In a binomial regression analysis, suprarenal angulation, infrarenal neck length, and type of stent graft were independent predictors of neck-related complications. Evolution from the Talent stent graft into the Endurant has resulted in significant reduction of infrarenal neck-related complications; on the other hand, iliac interventions increased. The overall midterm secondary intervention rate was comparable. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Adaptive significance of root grafting in trees

    Energy Technology Data Exchange (ETDEWEB)

    Loehle, C.; Jones, R.

    1988-12-31

    Root grafting has long been observed in forest trees but the adaptive significance of this trait has not been fully explained. Various authors have proposed that root grafting between trees contributes to mechanical support by linking adjacent root systems. Keeley proposes that this trait would be of greatest advantage in swamps where soils provide poor mechanical support. He provides as evidence a greenhouse study of Nyssa sylvatica Marsh in which seedlings of swamp provenance formed between-individual root grafts more frequently than upland provenance seedlings. In agreement with this within-species study, Keeley observed that arid zone species rarely exhibit grafts. Keeley also demonstrated that vines graft less commonly than trees, and herbs never do. Since the need for mechanical support coincides with this trend, these data seem to support his model. In this paper, the authors explore the mechanisms and ecological significance of root grafting, leading to predictions of root grafting incidence. Some observations support and some contradict the mechanical support hypothesis.

  16. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  17. Impact of donor-specific anti-HLA antibodies on graft failure and survival after reduced intensity conditioning-unrelated cord blood transplantation: a Eurocord, Société Francophone d'Histocompatibilité et d'Immunogénétique (SFHI) and Société Française de Greffe de Moelle et de Thérapie Cellulaire (SFGM-TC) analysis.

    Science.gov (United States)

    Ruggeri, Annalisa; Rocha, Vanderson; Masson, Emeline; Labopin, Myriam; Cunha, Renato; Absi, Lena; Boudifa, Ali; Coeffic, Brigitte; Devys, Anne; De Matteis, Muriel; Dubois, Valérie; Hanau, Daniel; Hau, Françoise; Jollet, Isabelle; Masson, Dominique; Pedron, Beatrice; Perrier, Pascale; Picard, Christophe; Ramouneau-Pigot, Annie; Volt, Fernanda; Charron, Dominique; Gluckman, Eliane; Loiseau, Pascale

    2013-07-01

    Graft failure is a major complication after unrelated cord blood transplantation. Presence of HLA-antibodies before cord blood transplantation may impact graft failure. To analyze the effect of anti-HLA antibodies on unrelated cord blood transplantation outcomes, we analyzed 294 unrelated cord blood transplant recipients after reduced intensity conditioning regimen. The majority of the patients (82%) were transplanted for malignancies, 60% with double-unrelated cord blood transplant, 63% were HLA mismatched. Retrospectively, pre-unrelated cord blood transplant serum was tested for HLA-Ab using Luminex™ platform. Results were interpreted as mean fluorescence intensity (MFI) against donor-specific mismatch. Among 62 recipients (23%) who had anti-HLA antibodies before unrelated cord blood transplant, 14 patients had donor specific anti-HLA antibodies (DSA) (7 were donor-specific anti-HLA antibodies for single unrelated cord blood transplant and 7 for double unrelated cord blood transplant). Donor specific anti-HLA antibodies threshold ranged from 1620-17629 of mean fluorescence intensity (MFI). Cumulative incidence of Day-60 neutrophil engraftment was 76%: 44% for recipients with donor specific anti-HLA antibodies and 81% in those without donor specific anti-HLA antibodies (P=0.006). The cumulative incidence of 1-year transplant related mortality was 46% in patients with donor specific anti-HLA antibodies and 32% in those without antibodies (P=0.06). The presence of donor specific anti-HLA antibodies was associated with a trend for decreased survival rate (42% vs. 29%; P=0.07). Donor specific anti-HLA antibody in recipients of unrelated cord blood transplant is associated with graft failure and decreased survival. Patient's screening for donor specific anti-HLA antibodies before unrelated cord blood transplantation is recommended before choosing an HLA mismatched cord blood unit. Whenever possible it is important to avoid selecting a unit for which the patient has

  18. Radiation-induced grafting of styrene on to LDPE films for preparation of cation exchange membranes, i. effect of grafting conditions

    International Nuclear Information System (INIS)

    Mohamed Mahmoud Nasef; Hamdani Saidi; Hussin Mohd Nor; Khairul Zaman Mohd Dahlan; Kamaruddin Hashim

    1999-01-01

    PE-g-polystyrene copolymers were prepared by simultaneous radiation-induced graft copolymerization of styrene onto low density polyethylene (LDPE) films. The effects of irradiation conditions such as monomer concentration, Mohr's salt and sulfuric acid addition, irradiation dose and dose rate were investigated. It was found that the degree of grafting increases with the monomer concentration and reaches its maximum value at styrene concentration of 80 vol %. The addition of Mohr's salt as well as sulfuric acid caused a considerable increase in the degree of grafting with various styrene concentrations. The degree of grafting also increased with the increased in irradiation dose, however it remarkably decreased with the increase in dose rate. The formation of graft copolymers was confirmed by FTIR analysis. The structural investigation of the graft copolymer was carried out by x-ray diffraction (XRD). The degree of crystallinity content was found to be decreased with the increase in the degree of grafting and influenced the mechanical properties of the graft copolymer to some extent. (Author)

  19. Complications in skin grafts when continuing antithrombotic therapy prior to cutaneous surgery requiring skin grafting

    DEFF Research Database (Denmark)

    Jarjis, Reem Dina; Jørgensen, Lone; Finnerup, Kenneth

    2015-01-01

    Abstract The risk of postoperative bleeding and wound healing complications in skin grafts among anticoagulated patients undergoing cutaneous surgery has not been firmly established. The objective was to examine the literature and assess the risk of postoperative bleeding or wound healing...... complications in skin grafts among anticoagulated patients, compared with patients who discontinue or patients who are not receiving antithrombotic therapy prior to cutaneous surgery requiring skin grafting. A systematic review examining the effect of antithrombotic therapy on cutaneous surgery was performed...... studies were of prospective and retrospective design. Most of the reviewed studies suggest that the use of antithrombotic therapy can increase the risk of bleeding complications in skin grafts. These complications are only wound threatening and not life threatening. Therefore, this is of concern mostly...

  20. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

    Science.gov (United States)

    Ghista, Dhanjoo N; Kabinejadian, Foad

    2013-12-13

    In this paper, coronary arterial bypass grafting hemodynamics and anastomosis designs are reviewed. The paper specifically addresses the biomechanical factors for enhancement of the patency of coronary artery bypass grafts (CABGs). Stenosis of distal anastomosis, caused by thrombosis and intimal hyperplasia (IH), is the major cause of failure of CABGs. Strong correlations have been established between the hemodynamics and vessel wall biomechanical factors and the initiation and development of IH and thrombus formation. Accordingly, several investigations have been conducted and numerous anastomotic geometries and devices have been designed to better regulate the blood flow fields and distribution of hemodynamic parameters and biomechanical factors at the distal anastomosis, in order to enhance the patency of CABGs. Enhancement of longevity and patency rate of CABGs can eliminate the need for re-operation and can significantly lower morbidity, and thereby reduces medical costs for patients suffering from coronary stenosis. This invited review focuses on various endeavors made thus far to design a patency-enhancing optimized anastomotic configuration for the distal junction of CABGs.

  2. Characterization and Some Properties of Functionalized Graft Copolymer

    International Nuclear Information System (INIS)

    Hegazy El-Sayed, A.; Kamal, H.; Mahmoud, Gh.A.; Khalifa, N.A.

    2000-01-01

    The study involved the investigation and characterization of membranes prepared by graft copolymerization of acrylonitrile (AN) and vinyl acetate (VAc) binary monomers onto low density polyethylene (LDPE) and isotactic polypropylene (IPP). The mutual gamma-irradiation method was used as a grafting technique. The effects of grafting and chemical treatments on the thermal properties and crystallinity of prepared graft copolymer have been investigated using DSC, TGA and XRD. IR spectra recorded before and after grafting and also for the chemically treated membranes to elucidate the structural changes occurred due to grafting and chemical treatments

  3. Radiation-induced grafting onto wool

    International Nuclear Information System (INIS)

    Muller-Schulte, D.

    1979-10-01

    Radiation-induced grafting tests were done on single wool fibres. Different vinyl monomers were used for this purpose and they were grafted in twenty different solvents which were selected for their swelling effiency and solvent parameters. The tests were done once with and once without the addition of water. The presence of water causes the polymer uptake to increase considerably. Formic acid/methanol and methanol were found to be the most suitable solvent systems, as they have the highest hydrogen-bond interaction effiency. The moisture uptake of wool depends on the hydrophily and hydrophoby of the grafted polymers. The single-fibre tests serve as a basis for analogous grafting tests on wool fabrics. The permanent- press was improved by graftng with hydrophoric polymers and polymers with a high glass-transition temperature [af

  4. Influence of radiation-induced grafting process on mechanical properties of ETFE-based membranes for fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Ben Youcef, H.; Alkan Guersel, S.; Buisson, A.; Gubler, L.; Wokaun, A.; Scherer, G.G. [Electrochemistry Laboratory, Paul Scherrer Institut, Villigen PSI (Switzerland)

    2010-06-15

    The mechanical stability is, in addition to thermal and chemical stability, a primary requirement of polymer electrolyte membranes in fuel cells. In this study, the impact of grafting parameters and preparation steps on stress-strain properties of ETFE-based proton conducting membranes, prepared by radiation-induced grafting and subsequent sulphonation, was studied. No significant change in the mechanical properties of the ETFE base film was observed below an irradiation dose of 50 kGy. It was shown that the elongation at break decreases with increasing both the crosslinker concentration and graft level (GL). However, the tensile strength was positively affected by the crosslinker concentration. Yield strength and modulus of elasticity are almost unaffected by the introduction of crosslinker. Interestingly, yield strength and modulus of elasticity increase gradually with GL without noticeable change of the inherent crystallinity of grafted films. The most brittle membranes are obtained via the combination of high GL and crosslinker concentration. The optimised ETFE-based membrane (GL of {proportional_to}25%, 5% DVB v/v), shows mechanical properties superior to those of Nafion registered 112 membrane. The obtained results were correlated qualitatively to the other ex situ properties, including crystallinity, thermal properties and water uptake of the grafted membranes. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  5. Polyether-polyester graft copolymer

    Science.gov (United States)

    Bell, Vernon L. (Inventor)

    1987-01-01

    Described is a polyether graft polymer having improved solvent resistance and crystalline thermally reversible crosslinks. The copolymer is prepared by a novel process of anionic copolymerization. These polymers exhibit good solvent resistance and are well suited for aircraft parts. Previous aromatic polyethers, also known as polyphenylene oxides, have certain deficiencies which detract from their usefulness. These commercial polymers are often soluble in common solvents including the halocarbon and aromatic hydrocarbon types of paint thinners and removers. This limitation prevents the use of these polyethers in structural articles requiring frequent painting. In addition, the most popular commercially available polyether is a very high melting plastic. This makes it considerably more difficult to fabricate finished parts from this material. These problems are solved by providing an aromatic polyether graft copolymer with improved solvent resistance and crystalline thermally reversible crosslinks. The graft copolymer is formed by converting the carboxyl groups of a carboxylated polyphenylene oxide polymer to ionic carbonyl groups in a suitable solvent, reacting pivalolactone with the dissolved polymer, and adding acid to the solution to produce the graft copolymer.

  6. Artificial Dermis Graft on the Mandible Lacking Periosteum After Excision of an Ossifying Fibroma: A Case Report

    Directory of Open Access Journals (Sweden)

    Chun-Ming Chen

    2007-07-01

    Full Text Available Collagen-based grafts have often been used as artificial tissue substitutes for the repair of tissue and organ defects. It is common surgical knowledge that autogenous or artificial skin grafts take well on the intact periosteum of bone. However, many experienced surgeons indicate that auto-genous or artificial skin grafts subsist poorly on the bone surface without periosteum. Therefore, primary closure is usually recommended in the wound healing of exposed bone. Vestibuloplasty might be needed to create enough depth of vestibule in the future. In this case report, we describe a peripheral ossifying fibroma surgically excised leaving a bony defect, which was covered by a piece of artificial dermis. Satisfactory result of the repaired surgical defect showed no need of vestibuloplasty after 6 years of follow-up.

  7. Physical training in patients with heart failure

    Directory of Open Access Journals (Sweden)

    Barbara Fletcher, RN, MN, FAAN

    2012-11-01

    Full Text Available Heart failure is a primary health concern in North and South America, with hospitalizations for heart failure as the primary diagnosis continuing to rise. There is a positive relationship between the prevalence of heart failure and age. However, mortality from heart failure is on the decline due to medical advancements, pharmacotherapy and nonpharmacological interventions. One of these nonpharmacological interventions is physical training or exercise. Physical training or exercise is becoming widely accepted by the medical community as a viable option in the medical management of stable heart failure patients. Both aerobic and resistance type exercise have been shown to be efficacious in stable heart failure patients. Evidence now exists not only supporting exercise to improve or maintain physical function in heart failure patients, but also quality of life. Many studies have shown that utilizing exercise in this population improves mood and overall self-reported well being. While the myocardial benefits from exercise may be minimal in heart failure patients, the peripheral benefits leading to improved physical function and preservation of independence are indispensible. Based on the research that has been conducted in the area of exercise and heart failure to this point, clinicians working with this population have the data necessary to prescribe evidence-based exercise prescriptions that can be utilized as part of a comprehensive medical management approach. Currently, several medical position statements endorse exercise as a safe and effective modality in heart failure patients.

  8. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate

  9. Basic concepts in metal work failure after metastatic spine tumour surgery.

    Science.gov (United States)

    Kumar, Naresh; Patel, Ravish; Wadhwa, Anshuja Charvi; Kumar, Aravind; Milavec, Helena Maria; Sonawane, Dhiraj; Singh, Gurpal; Benneker, Lorin Michael

    2018-04-01

    The development of spinal implants marks a watershed in the evolution of metastatic spine tumour surgery (MSTS), which has evolved from standalone decompressive laminectomy to instrumented stabilization and decompression with reconstruction when necessary. Fusion may not be feasible after MSTS due to poor quality of graft host bed along with adjunct chemotherapy and/or radiotherapy postoperatively. With an increase in the survival of patients with spinal tumours, there is a probability of an increase in the rate of implant failure. This review aims to help establish a clear understanding of implants/constructs used in MSTS and to highlight the fundamental biomechanics of implant/construct failures. Published literature on implant failure after spine surgery and MSTS has been reviewed. The evolution of spinal implants and their role in MSTS has been briefly described. The review defines implant/construct failures using radiological parameters that are practical, feasible, and derived from historical descriptions. We have discussed common modes of implant/construct failure after MSTS to allow further understanding, interception, and prevention of catastrophic failure. Implant failure rates in MSTS are in the range of 2-8%. Variability in patterns of failure has been observed based on anatomical region and the type of constructs used. Patients with construct/implant failures may or may not be symptomatic and present either as early (failures (> 3months). It has been noted that not all the implant failures after MSTS result in revisions. Based on the observed radiological criteria and clinical presentations, we have proposed a clinico-radiological classification for implant/construct failure after MSTS.

  10. Improved patency and reduced intimal hyperplasia in PTFE grafts with luminal immobilized heparin compared with standard PTFE grafts at six months in a sheep model.

    Science.gov (United States)

    Pedersen, G; Laxdal, E; Ellensen, V; Jonung, T; Mattsson, E

    2010-06-01

    The aim of this study was to compare the performance of polytetrafluoroethylene (PTFE) grafts with luminal coating of immobilized heparin to that of standard PTFE grafts at six months. Twenty-eight common carotid arteries in fourteen sheep were bypassed with heparin-coated PTFE grafts (6 mm diameter, 6 cm length) on one side and standard PTFE grafts on the other. The grafts were explanted after six months. The thickness of intimal hyperplasia (IH) in open grafts was measured with histomorphometrical methods. Two of 14 heparinized PTFE grafts and nine of 14 grafts in the control PTFE-group were occluded at explantation (P=0.006). Six-month patency rates for heparinized PTFE grafts and for standard PTFE grafts were 86% and 36%, respectively. Mean graft anastomotic IH thickness in open grafts were 0.074 mm for heparinized PTFE grafts and 0.259 mm for PTFE-grafts (P=0.006). PTFE grafts with luminal coating containing immobilized heparin had significantly better patency and recruited less intimal hyperplasia than standard PTFE grafts at six months.

  11. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    Science.gov (United States)

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high

  12. Polyether/Polyester Graft Copolymers

    Science.gov (United States)

    Bell, Vernon L., Jr.; Wakelyn, N.; Stoakley, D. M.; Proctor, K. M.

    1986-01-01

    Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

  13. Preparation of Dimethylaminoethylmethacrylate Grafted Polymeric Adsorbent by Using Radiation-Induced Grafting Technique for Removal of Anions

    International Nuclear Information System (INIS)

    Kavakli, P. A.

    2006-01-01

    The development of efficient separation and purification techniques is very important from industrial, environmental and economic points of view. Polymeric materials having polyfunctional groups such as carboxylic, amide, nitrile, iminodiacetic acid, amidoxime, and ammonium groups, etc., not only possess good hydrophilic properties, but also have good ion exchange properties which make them suitable for metal recovery from aqueous solutions. Radiation induced grafting is a powerful technique capable of controlling the introduction of various functional groups to the polymeric materials, keeping the original properties and especially the mechanical strength of the base material, and thus, allowing the synthesis of more stable polymeric adsorbents. The main objective of this study was to develop special polymeric adsorbents to remove NOx and PO 4 anions from aqueous systems. For this purpose, a novel nonwoven fabric was prepared by radiation-induced graft polymerization of imethylaminoethylmethacrylate (DMAEMA) onto polypropylene coated polyethylene nonwoven fabric. The trunk polymer was irradiated by electron beam at a voltage of 2 MeV and a current of 3 mA in a nitrogen atmosphere at dry-ice temperature at different doses. The degree of grafting was determined as a function of the total dose, monomer concentration, temperature, and reaction time. It was found that the degree of grafting of grafted polymer was greatly affected by reaction conditions. Grafting conditions were optimized, and about 150 % degree of grafting samples was used for further experiments. DMAEMA grafted polymer was later protonated by using acid solution to prepare adsorbent for the removal of anions. Adsorption experiments were performed in column mode for removal of phosphate. Approximately 2000 bed volumes of phosphate-free water can be produced from 10 ppb phosphate solution at high space velocity

  14. The Impact of Timing and Graft Dysfunction on Survival and Cardiac Allograft Vasculopathy in Antibody Mediated Rejection

    Science.gov (United States)

    Clerkin, Kevin J.; Restaino, Susan W.; Zorn, Emmanuel; Vasilescu, Elena R.; Marboe, Charles C.; Mancini, Donna M.

    2017-01-01

    Background Antibody mediated rejection (AMR) has been associated with increased mortality and cardiac allograft vasculopathy (CAV). Early studies suggested that late AMR was rarely associated with graft dysfunction while recent reports have demonstrated an association with increased mortality. We sought to investigate the timing of AMR and its association with graft dysfunction, mortality, and CAV. Methods This retrospective cohort study identified all adult heart transplant recipients at Columbia University Medical Center from 2004–2013 (689 patients). There were 68 primary cases of AMR, which were stratified by early (1-year post-OHT) AMR. Kaplan-Meier survival analysis and modeling was performed with multivariable logistic regression and Cox proportional hazards regression. Results From January 1, 2004 through October 1, 2015 43 patients had early AMR (median 23 days post-OHT) and 25 had late AMR (median 1084 days post-OHT). Graft dysfunction was less common with early compared with late AMR (25.6% vs. 56%, p=0.01). Patients with late AMR had decreased post-AMR survival compared with early AMR (1-year 80% vs. 93%, 5-year 51% vs. 73%, p<0.05). When stratified by graft dysfunction, only those with late AMR and graft dysfunction had worse survival (30-day 79%, 1-year 64%, and 5-year 36%, p<0.006). The association remained irrespective of age, sex, DSA, LVAD use, reason for OHT, and recovery of graft function. Similarly, those with late AMR and graft dysfunction had accelerated development of de-novo CAV (50% at 1 year, HR 5.42, p=0.009), while all other groups were all similar to the general transplant population. Conclusion Late AMR is frequently associated with graft dysfunction. When graft dysfunction is present in late AMR there is an early and sustained increased risk of mortality and rapid development of de-novo CAV despite aggressive treatment. PMID:27423693

  15. Radiation induced graft copolymerization of jute fibre

    International Nuclear Information System (INIS)

    Al-Siddique, F.R.; Khan, A.U.; Sheikh, R.A.

    1983-01-01

    Graft copolymerized jute fibres (GCJF) were prepared by γ-ray induced graft copolymerization of various monomers onto bleached and de-waxed jute samples. The effect of γ-ray dose on the tendency of various monomers to form graft co-polymer was studied. It was found that the tendency decreases as follows: methylmethacrylate (MMA)>acrylonitrile (AN)>styrene (STY)>vinylacetate (VA). When the effect of monomer concentration on the formation of graft co-polymer was studied, it was found that a mixture of AN and STY gave a higher amount of grafting than what was observed for STY or AN alone, when used at a comparable concentration. A study on the effect of concentration of methyl alcohol (a swelling agent for jute) on the tendency of the monomers to form graft co-polymer showed that although there is no effect when only AN is used, an appreciable effect is observed if AN is mixed with STY. In the later case the tendency of graft co-polymerization increases with the increase of CH 3 OH concentration. It was further observed that the increase of CH 3 OH also has a positive influence on MMA to form graft co-polymer in the range of 40-90% CH 3 OH. The affinity of GCJF towards moisture has been found to decrease with the increase of polymer loading onto jute. The presence of swelling agents during graft copolymer formation was also found to decrease the affinity of GCJF towards moisture. (author)

  16. Graft-free Ahmed tube insertion: a modified method at 5 mm from limbus

    Directory of Open Access Journals (Sweden)

    Juan Carlos Mesa-Gutiérrez

    2010-04-01

    Full Text Available Juan Carlos Mesa-Gutiérrez, Juan Lillo-Sopena, Anna Monés-Llivina, Silvia Sanz-Moreno, Jorge Arruga-GinebredaDepartment of Ophthalmology, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Barcelona, SpainObjective: To determine the medium-term outcome of Ahmed implants inserted through a needle tract at 5 mm from limbus that eliminates the need for a donor scleral graft.Methods: A retrospective case series of 19 patients undergoing Ahmed implant surgery for refractory glaucoma with a mean follow-up of 12 months. Primary outcome measures included control of intraocular pressure after surgery. Secondary outcome measure included the frequency of intraoperative and postoperative complications.Results: Intraocular pressure was maintained between 6 and 21 mmHg throughout the study. There was no postoperative hypotony. There were no complications related to this modified technique.Conclusion: Needle tract at 5 mm from limbus maintains implant’s ability to control intraocular pressure and eliminates the need for a donor scleral graft or heterologous material.Keywords: surgical technique, Ahmed implant, refractory glaucoma, donor scleral graft, tube shunt device

  17. Unprotected autogenous bone block grafts in anterior maxilla: Resorption rates and clinical outcomes

    Directory of Open Access Journals (Sweden)

    Kosanić Ivan

    2017-01-01

    Full Text Available Background/Aim. The use of autogenous bone grafts for augmentation of the resorbed alveolar ridge is still considered the gold standard in implant dentistry. The aim of this study was to analyze the resorption rate of autogenous bone block grafts from the retromolar region placed in the frontal segment of the upper jaw unprotected by barrier membranes, to assess the stability of implants placed into the grafted bone, as well as to monitor its changes during the healing period. Methods. The study included 18 patients with a total of 20 grafted sites. The residual alveolar ridge was measured before and after the augmentation and prior to implant placement. All implants were restored with provisional crowns within 48 hours after the placement. Implant stability was assessed using resonance frequency analysis. Results. The average period from ridge augmentation to reentry was 5.4 months (range 4–6 months. At reentry the healed alveolar ridge had a mean width of 6.1 ± 1.27 mm. The mean calculated width gain was 3.04 ± 1.22 mm. The overall surface resorption of block grafts was 0.68 ± 0.69 mm (18.85%. At the time of implant placement the mean value of implant stability quotient (ISQ was 71.25 ± 5.77. The lowest ISQ values were noted after three weeks of healing, followed by a gradual increase until week 12. After 12 weeks implants showed significantly higher ISQ values compared to primary stability (p < 0.05 Wilcoxon signed ranks test. During the 3-years followup period no cases of implant loss were recorded. Conclusion. Despite a significant resorption of bone grafts, it was possible to place implants in all the cases and to use the immediate loading protocol without affecting implant survival rate. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no.175021

  18. The effect of monomer molecular weight on grafting reaction

    International Nuclear Information System (INIS)

    Wu Minghong; Ding Zhongli; Ma Zueteh

    1995-01-01

    In this paper, some condensed ethylene glycol acrylate monomers with different molecular weight being grafted to the PE film by means of pre-irradiation is reported. The effect of molecular weight of monomer on grafting reaction and the hydrophilicity of grafting sample have been discussed. The experimental results show: molar degrees of grafting decreased non-linearly with the increasement of molecular weight of monomer, the grafting reaction of polymer is greater effected by the swelling degree of PE film, the greater the swelling degree of grafting material, the higher the grating degree grafting is, the initial rate of grafting reaction decreased with the increasement of molecular weight of monomer. (author)

  19. Unraveling the Mechanisms of Cutaneous Graft-Versus-Host Disease

    Directory of Open Access Journals (Sweden)

    Pedro Santos e Sousa

    2018-05-01

    Full Text Available The skin is the most common target organ affected by graft-versus-host disease (GVHD, with severity and response to therapy representing important predictors of patient survival. Although many of the initiating events in GVHD pathogenesis have been defined, less is known about why treatment resistance occurs or why there is often a permanent failure to restore tissue homeostasis. Emerging data suggest that the unique immune microenvironment in the skin is responsible for defining location- and context-specific mechanisms of injury that are distinct from those involved in other target organs. In this review, we address recent advances in our understanding of GVHD biology in the skin and outline the new research themes that will ultimately enable design of precision therapies.

  20. [An experimental study of the healing of velour grafts].

    Science.gov (United States)

    Kobayashi, O

    1986-02-01

    An experimental study of implantation of velour grafts in the abdominal aorta or the external iliac artery of dogs was conducted with the object of evaluating the type of velour surface best fit for small-caliber artery implantation. Velour grafts measuring 4mm in diameter with differing velour surfaces were used as materials. Velour grafts now available on the market differ not only in velour surface but also in structure, notably in porosity and wall thickness. Hence each of the grafts used was reversed (i.e. inside out) and thus new grafts were prepared. These grafts were considered most suitable for making a comparative study of the effects of velour surface on healing. Macroscopic and histological findings revealed that each graft was good healing with the rate of patency as high as 84 percent. However, like Vasculour-D grafts, crimped grafts which preserve the crimp after implantation was significantly thicker at the internal valley than other grafts. Based on the findings of this experimental study non-crimped velour grafts were considered to be best fit for small-caliber artery implantation.