WorldWideScience

Sample records for primary flow unit

  1. Primary separator replacement for Bruce Unit 8 steam generators

    International Nuclear Information System (INIS)

    Roy, S.B.; Mewdell, C.G.; Schneider, W.G.

    2000-01-01

    During a scheduled maintenance outage of Bruce Unit 8 in 1998, it was discovered that the majority of the original primary steam separators were damaged in two steam generators. The Bruce B steam generators are equipped with GXP type primary cyclone separators of B and W supply. There were localized perforations in the upper part of the separators and large areas of generalized wall thinning. The degradation was indicative of a flow related erosion corrosion mechanism. Although the unit- restart was justified, it was obvious that corrective actions would be necessary because of the number of separators affected and the extent of the degradation. Repair was not considered to be a practical option and it was decided to replace the separators, as required, in Unit 8 steam generators during an advanced scheduled outage. GXP separators were selected for replacement to minimize the impact on steam generator operating characteristics and analysis. The material of construction was upgraded from the original carbon steel to stainless steel to maximize the assurance of full life. The replacement of the separators was a first of a kind operation not only for Ontario Power Generation and B and W but also for all CANDU plants. The paper describes the degradations observed and the assessments, the operating experience, manufacture and installation of the replacement separators. During routine inspection in 1998, many of the primary steam separators in two of steam generators at Bruce Nuclear Division B Unit 8 were observed to have through wall perforations. This paper describes assessment of this condition. It also discusses the manufacture and testing of replacement primary steam separators and the development and execution of the replacement separator installation program. (author)

  2. Identification and control of factors influencing flow-accelerated corrosion in HRSG units using computational fluid dynamics modeling, full-scale air flow testing, and risk analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pietrowski, Ronald L. [The Consolidated Edison Company of New York, Inc., New York, NY (United States)

    2010-11-15

    In 2009, Consolidated Edison's East River heat recovery steam generator units 10 and 20 both experienced economizer tube failures which forced each unit offline. Extensive inspections indicated that the primary failure mechanism was flow-accelerated corrosion (FAC). The inspections revealed evidence of active FAC in all 7 of the economizer modules, with the most advanced stages of degradation being noted in center modules. Analysis determined that various factors were influencing and enabling this corrosion mechanism. Computational fluid dynamics and full-scale air flow testing showed very turbulent feedwater flow prevalent in areas of the modules corresponding with the pattern of FAC damage observed through inspection. It also identified preferential flow paths, with higher flow velocities, in certain tubes directly under the inlet nozzles. A FAC risk analysis identified more general susceptibility to FAC in the areas experiencing damage due to feedwater pH, operating temperatures, local shear fluid forces, and the chemical composition of the original materials of construction. These, in combination, were the primary root causes of the failures. Corrective actions were identified, analyzed, and implemented, resulting in equipment replacements and repairs. (orig.)

  3. Revealing flow behaviors of metallic glass based on activation of flow units

    Energy Technology Data Exchange (ETDEWEB)

    Ge, T. P.; Wang, W. H.; Bai, H. Y., E-mail: hybai@iphy.ac.cn [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2016-05-28

    Atomic level flow plays a critical role in the mechanical behavior of metallic glass (MG) while the connection between the flow and the heterogeneous microstructure of the glass remains unclear. We describe the heterogeneity of MGs as the elastic matrix with “inclusions” of nano-scale liquid-like flow units, and the plastic flow behavior of MGs is considered to be accommodated by the flow units. We show that the model can explain the various deformation behaviors, the transformation from inhomogeneous deformation to homogeneous flow upon strain rate or temperature, and the deformation map in MGs, which might provide insights into the flow mechanisms in glasses and inspiration for improving the plasticity of MGs.

  4. Detailed flow analysis for the Three Mile Island unit 2 reactor accident

    International Nuclear Information System (INIS)

    Lillington, J.N.; Lyons, A.J.

    1990-01-01

    Some particular characteristics of the steam flow in the accident at the Three Mile Island unit 2 pressurized water reactor are investigated using the AEA Technology Flow3D code. Natural circulation flows with heat removal from the core and deposition in the upper plenum are predicted during the primary heating phase. The structure of the upper plenum cylinder and core blockage, owing to material relocation, are shown to force the flow into a complex three-dimensional pattern. The flows and temperature distributions from the calculations are shown to be consistent with the observed damage pattern above the core. Despite high core temperatures, damage was limited by the operation of one of the pumps at the end of the initial heating phase. Flow3D calculations are also carried out to demonstrate that the three-dimensional buoyancy driven flows are completely destroyed by the high steam generation rates arising from the pump operation. (author)

  5. The flow measurement plan for the primary system of SMART

    International Nuclear Information System (INIS)

    Lee, Jun; Seo, J. K.; Park, C. T.; Yoon, J. H.; Cho, B. H.; Lee, D. J.

    2001-08-01

    It is the common features of the integrated reactor that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integrated reactor, and it also makes impossible measure the primary coolant flow rate. SMART is also a integrated reactor type, and have a problem as same as the above case. The objective of the study is to draw up the flow measurement plan for the primary system of SMART. In this study, firstly we reviewed the flow measurement methods at the primary system for the existing commercial nuclear power reactors. As a result of the review, we selected preliminarily the 3 methods which is a good possibility of application to SMART. The 3 methods are as follows. Flow measurement method by MCP rotation speed, flow measurement method by HBM, flow measurement method by pump motor power. For the above methods, we have evaluated whether they actually can be applied to SMART, and also have set up the concrete methodology. Finally we have made a selection of the above methods as the flow measurement plan for the primary system of SMART. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for SMART, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  6. The flow measurement methods for the primary system of integral reactors

    International Nuclear Information System (INIS)

    Lee, J.; Seo, J. K.; Lee, D. J.

    2001-01-01

    It is the common features of the integral reactors that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integral reactors, and it also makes impossible measure the primary coolant flow rate. The objective of the study is to draw up the flow measurement methods for the primary system of integral reactors. As a result of the review, we have made a selection of the flow measurement method by pump speed, bt HBM, and by pump motor power as the flow measurement methods for the primary system of integral reactors. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for integral reactors, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  7. Flow-Control Unit For Nitrogen And Hydrogen Gases

    Science.gov (United States)

    Chang, B. J.; Novak, D. W.

    1990-01-01

    Gas-flow-control unit installed and removed as one piece replaces system that included nine separately serviced components. Unit controls and monitors flows of nitrogen and hydrogen gases. Designed for connection via fluid-interface manifold plate, reducing number of mechanical fluid-interface connections from 18 to 1. Unit provides increasing reliability, safety, and ease of maintenance, and for reducing weight, volume, and power consumption.

  8. Lessons learnt from the resin release into the primary circuit of the Fessenheim NPP unit 1 in January 2004. Impact on the nuclear safety

    International Nuclear Information System (INIS)

    Georgescu, M.

    2004-01-01

    On January the 24 th , at the Fessenheim NPP unit 1, a human error was committed during a boron demineralizer line-up, caused by lack of preparation. Consequently, a quantity of resin estimated at about 300 liters was released from this demineralizer, through its safety valve, into the head-tank of the chemical and volume control (CVC) system and after that, into the primary circuit. The incident had a real impact on the unit: the CVC filters were clogged, the seal injection flow of the primary circuit main pumps was lost, the primary circuit main pump 2 tripped four days after the incident, as the rate of the recirculated seal leak flow (downstream the seal 1) increased up to the automatic trip set point, the shaft of the running primary circuit feed pump was found seized into the rear hydrostatic bearing following the pump stop (after ten days of successful operation), the thimble plugs were jammed into their guide tubes, the small diameter pipes were plugged. The unit shutdown for over five months was necessary to clean the primary circuit components, repair or replace the affected equipment items and carry out inspections and tests. The reinforced unit in-service monitoring program, set up during the unit start-up, confirms that, up to now, the unit operation has not been adversely affected by the residual amounts of resin which subsist in certain areas of the primary circuit. Nevertheless, it remains to verify that, in the long term, these deposits will have no negative chemical effect in the potential confined areas, such as the thermal barriers of the primary circuit main pumps. Finally, the occurrence of this incident underlines, once more, the importance of normal operating activity preparing and checking. It also reveals the implementation of an ''unforgiving'' design change allowing the installation of a boron demineralizer safety valve having its outlet connected to the primary circuit. (orig.)

  9. Oscillatory fluid flow influences primary cilia and microtubule mechanics.

    Science.gov (United States)

    Espinha, Lina C; Hoey, David A; Fernandes, Paulo R; Rodrigues, Hélder C; Jacobs, Christopher R

    2014-07-01

    Many tissues are sensitive to mechanical stimuli; however, the mechanotransduction mechanism used by cells remains unknown in many cases. The primary cilium is a solitary, immotile microtubule-based extension present on nearly every mammalian cell which extends from the basal body. The cilium is a mechanosensitive organelle and has been shown to transduce fluid flow-induced shear stress in tissues, such as the kidney and bone. The majority of microtubules assemble from the mother centriole (basal body), contributing significantly to the anchoring of the primary cilium. Several studies have attempted to quantify the number of microtubules emanating from the basal body and the results vary depending on the cell type. It has also been shown that cellular response to shear stress depends on microtubular integrity. This study hypothesizes that changing the microtubule attachment of primary cilia in response to a mechanical stimulus could change primary cilia mechanics and, possibly, mechanosensitivity. Oscillatory fluid flow was applied to two different cell types and the microtubule attachment to the ciliary base was quantified. For the first time, an increase in microtubules around primary cilia both with time and shear rate in response to oscillatory fluid flow stimulation was demonstrated. Moreover, it is presented that the primary cilium is required for this loading-induced cellular response. This study has demonstrated a new role for the cilium in regulating alterations in the cytoplasmic microtubule network in response to mechanical stimulation, and therefore provides a new insight into how cilia may regulate its mechanics and thus the cells mechanosensitivity. Copyright © 2014 Wiley Periodicals, Inc.

  10. Decoding flow unit evolution upon annealing from fracture morphology in metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Gao, M., E-mail: gaomeng10@hotmail.com; Cao, X.F.; Ding, D.W.; Wang, B.B.; Wang, W.H., E-mail: whw@iphy.ac.cn

    2017-02-16

    The intrinsic correlation between the fracture morphology evolution and the structural heterogeneity of flow units in a typical Zr{sub 52.5}Ti{sub 5}Cu{sub 17.9}Ni{sub 14.6}Al{sub 10} (vit105) metallic glass (MG) upon annealing was investigated. By systematically tuning the annealing time at temperature below the glass transition temperature, a series of dimple-like fracture morphology were obtained, which is the unique fingerprint-like pattern for every annealing state. Based on the structural relaxation model of flow units, the evolution of the typical dimple sizes, the largest and smallest dimple size, with annealing were well fitted. Then the evolution of flow unit density was estimated from the fracture morphology evolution, which displays the same evolution trend with that measured from thermal relaxation. A stochastic dynamic model considering the interaction of activated flow units was proposed to analyze the effect of the initial flow unit density and the flow unit interaction intensity on the dynamic evolution of dimple distribution. Our work may provide a novel scheme to investigate the structural fingerprint information on flow units from fracture morphology, and enlighten the microscopic structural origin of the ductile-to-brittle transition during structural relaxation in MGs.

  11. Pressure fluctuation characteristics of flow field of mixed flow nuclear primary pump

    International Nuclear Information System (INIS)

    Wang Chunlin; Yang Xiaoyong; Li Changjun; Jia Fei; Zhao Binjuan

    2013-01-01

    In order to research the pressure fluctuation characteristics of flow field of mixed flow nuclear primary pump, this study used the technique of ANSYS-Workbench and CFX fluid solid heat coupling to do numerical simulation analysis for model pump. According to the situation of pressure fluctuation of time domain and frequency domain, the main cause of pressure fluctuation was discussed. For different flow, the pressure fluctuations were compared. This study shows it is feasible that large eddy simulation method is used for the research of pressure fluctuation. The pressure fluctuation amplitudes of four sections are increasing from wheel hub to wheel rim. The pressure fluctuation of inlet and outlet of impeller depends on the rotational frequency of impeller. Along with the fluid flowing away from the impeller, the effect of the impeller on the fluid pressure fluctuation weakens gradually. Comparing the different results of three flow conditions, the pressure fluctuation in design condition flow is superior to the others. (authors)

  12. Primary flow and temperature measurements in PWRS using non-invasive techniques

    International Nuclear Information System (INIS)

    Favennec, J.M.; Jossinet, G.; Thomas, P.

    1995-08-01

    PWR primary flow and temperature measurements are classically done with either indirect or invasive techniques. EDF has developed and installed non-invasive innovative techniques on an industrial nuclear power plant (Chooz N1 type PWR). Primary flow-rate is determined by measurement of velocity of primary water in the hot leg: the time fluctuation of γ-ray activity from Nitrogen-16 (produced by neutron activation of 016) is measured outside of the pipe by two specially-designed detectors. The signals from both detectors are then cross-correlated to determine the transit time of primary water between the two detectors; primary flow-rate is then deduced Primary temperature is determined by measurement of sound velocity in hot and cold leg: two pairs of ultrasonic transducers, installed on pipe outer wall, emit pulses periodically, for which the time of flight along the two pipes diameters are determined. The sound velocity thus computed (diameter over time of flight) is then converted into temperature, by use of a calibration formula relating sound velocity to temperature and pressure. This paper addresses metrological and technical aspects of the methods. Experience feedback on industrial PWRs is also presented. (author). 4 refs., 13 figs

  13. Functioning of primary health care in opinion of managers of primary health care units.

    Science.gov (United States)

    Bojar, I; Wdowiak, L; Kwiatosz-Muc, M

    2006-01-01

    The aim of the research is to get to know opinions of primary health care managers concerning working of primary health care and concerning quality of medical services offered by family doctors out-patient clinics. The research among managers of primary health care units took place in all out-patient clinics in Lublin province. Research instrument was survey questionnaire of authors own construction. Results were statistically analyzed. From 460 surveys sent, 108 questionnaires were accepted to analysis. Majority of managers of out-patient clinics of primary health care is satisfied with the way and the quality of work of employed staff. In opinion of 71.3% of managers access to family doctor services is very good. Availability of primary health care services is better estimated by managers of not public units. The occupied local provide comfortable work for the staff in opinion of 78.5% of surveyed managers of out-patient clinics. Managers estimate the level of their services as very good (37.96%) and good (37.96%) comparing to other such a subjects present in the market. Internal program of improving quality is run in 22% of out-patient clinics, which were investigated. Managers of primary health care units assess the quality of their services as good and very good. They estimate positively the comfort and politeness in serving patients as well as technical status of equipment and the lodging. They assess availability of their services as very good. Large group of managers of family doctors practices recognizes neighborhood practices as a competitors.

  14. Stability of Armour Units in Oscillatory Flow

    OpenAIRE

    Burcharth, Hans F.; Thompson, A. C.

    1983-01-01

    As part of a program to study the hydraulics of wave attack on rubble mound breakwaters tests were made on model armour units in a steady flow through a layer laid on a slope. The flow angle has little effect on stability for dolosse or rock layers. The head drop at failure across each type of layer is similar but the dolosse layer is more permeable and fails as a whole. There was no viscous scale effect. These results and earlier tests in oscillating flow suggest a 'reservoir' effect is impo...

  15. Stability of Armour Units in Oscillatory Flow

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Thompson, A. C.

    1983-01-01

    As part of a program to study the hydraulics of wave attack on rubble mound breakwaters tests were made on model armour units in a steady flow through a layer laid on a slope. The flow angle has little effect on stability for dolosse or rock layers. The head drop at failure across each type...... of layer is similar but the dolosse layer is more permeable and fails as a whole. There was no viscous scale effect. These results and earlier tests in oscillating flow suggest a 'reservoir' effect is important in the stability in steep waves....

  16. Reverse primary-side flow in steam generators during natural circulation cooling

    International Nuclear Information System (INIS)

    Stumpf, H.; Motley, F.; Schultz, R.; Chapman, J.; Kukita, Y.

    1987-01-01

    A TRAC model of the Large Scale Test Facility with a 3-tube steam-generator model was used to analyze natural-circulation test ST-NC-02. For the steady state at 100% primary mass inventory, TRAC was in excellent agreement with the natural-circulation flow rate, the temperature distribution in the steam-generator tubes, and the temperature drop from the hot leg to the steam-generator inlet plenum. TRAC also predicted reverse flow in the long tubes. At reduced primary mass inventories, TRAC predicted the three natural-circulation flow regimes: single phase, two phase, and reflux condensation. TRAC did not predict the cyclic fill-and-dump phenomenon seen briefly in the test. TRAC overpredicted the two-phase natural-circulation flow rate. Since the core is well cooled at this time, the result is conservative. An important result of the analysis is that TRAC was able to predict the core dryout and heatup at approximately the same primary mass inventory as in the test. 4 refs., 8 figs., 2 tabs

  17. Prevalence of health promotion programs in primary health care units in Brazil

    Science.gov (United States)

    Ramos, Luiz Roberto; Malta, Deborah Carvalho; Gomes, Grace Angélica de Oliveira; Bracco, Mário M; Florindo, Alex Antonio; Mielke, Gregore Iven; Parra, Diana C; Lobelo, Felipe; Simoes, Eduardo J; Hallal, Pedro Curi

    2014-01-01

    OBJECTIVE Assessment of prevalence of health promotion programs in primary health care units within Brazil’s health system. METHODS We conducted a cross-sectional descriptive study based on telephone interviews with managers of primary care units. Of a total 42,486 primary health care units listed in the Brazilian Unified Health System directory, 1,600 were randomly selected. Care units from all five Brazilian macroregions were selected proportionally to the number of units in each region. We examined whether any of the following five different types of health promotion programs was available: physical activity; smoking cessation; cessation of alcohol and illicit drug use; healthy eating; and healthy environment. Information was collected on the kinds of activities offered and the status of implementation of the Family Health Strategy at the units. RESULTS Most units (62.0%) reported having in place three health promotion programs or more and only 3.0% reported having none. Healthy environment (77.0%) and healthy eating (72.0%) programs were the most widely available; smoking and alcohol use cessation were reported in 54.0% and 42.0% of the units. Physical activity programs were offered in less than 40.0% of the units and their availability varied greatly nationwide, from 51.0% in the Southeast to as low as 21.0% in the North. The Family Health Strategy was implemented in most units (61.0%); however, they did not offer more health promotion programs than others did. CONCLUSIONS Our study showed that most primary care units have in place health promotion programs. Public policies are needed to strengthen primary care services and improve training of health providers to meet the goals of the agenda for health promotion in Brazil. PMID:25372175

  18. [Primary care in the United Kingdom].

    Science.gov (United States)

    Sánchez-Sagrado, T

    2016-03-01

    The inadequate planning of health professionals in Spain has boosted the way out of doctors overseas. The United Kingdom is one of the countries chosen by Spanish doctors to develop their job. The National Health Service is a health system similar to the Spanish one. Health care services are financing mainly through taxes. The right to health care is linked to the citizen condition. The provision of health care is a mix-up of public and private enterprises. Primary Care is much closed to Spanish Primary Care. Doctors are "self-employed like" professionals. They can set their surgeries in a free area previously designed by the government. They have the right to make their own team and to manage their own budget. Medical salary is linked to professional capability and curriculum vitae. The main role of a General Practitioner is the prevention. Team work and coordination within primary and specialised care is more developed than in Spain. The access to diagnostic tests and to the specialist is controlled through waiting lists. General Practitioners work as gate-keepers. Patients may choose freely their doctor and consultations and hospital care are free at the point of use. Within the United Kingdom there are also health regions with problems due to inequalities to access and to treatment. There is a training path and the access to it is by Curricula. The number of training jobs is regulated by the local needs. Continuing education is compulsory and strictly regulated local and nationally. The National Health Service was the example for the Spanish health reform in 1986. While Spanish Primary health care is of quality, the efficiency of the health system would improve if staff in Primary Care settings were managed in a similar way to the British's. Copyright © 2015 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Energy saving opportunity with variable speed drive in primary air-handling unit

    International Nuclear Information System (INIS)

    Li, J.S.M.

    2007-01-01

    Air conditioners used in the court buildings in Kowloon City, Hong Kong were retrofitted with variable speed drives in the primary air handling unit (PAU) in an effort to reduce energy consumption. The initial effect of this retrofit was investigated along with the feasibility of using a carbon dioxide (CO 2 ) based demand control ventilation to reduce energy consumption while optimizing indoor air quality. The air flow in most air conditioning fans is either constant or controlled by motorized inlet guide vanes. Although this controls the flow and may reduce the load on the fan, this constriction adds an energy loss, resulting in inefficient operation. Variable speed drives should be used on the PAU in order to maintain system efficiency. As the speed of the fans are reduced, the flow will decrease proportionally, while the power required by the fan will reduce the cube of the speed. Therefore, if the fresh air supply can be controlled by reducing the speed of the fan motor, then flow control would be more efficient. The energy saving associated with variable fresh air supply flow rate was evaluated along with the cost to building owners. This paper presented the results of the potential energy and cost savings associated with this retrofit, and included implementation cost and pay back period. It was estimated that about 20 per cent of power consumption and electricity costs can be saved per year, with a simple payback period of 2 years. 7 refs., 3 tabs., 3 figs

  20. Reduced coronary flow and resistance reserve in primary scleroderma myocardial disease

    International Nuclear Information System (INIS)

    Nitenberg, A.; Foult, J.M.; Kahan, A.; Perennec, J.; Devaux, J.Y.; Menkes, C.J.; Amor, B.

    1986-01-01

    The maximum coronary vasodilator capacity after intravenous dipyridamole (0.14 mg X kg-1 X min-1 X 4 minutes) was studied in seven patients with primary scleroderma myocardial disease and compared to that of seven control subjects. Hemodynamic data and left ventricular angiographic data were not different in the two groups. The coronary flow reserve was evaluated by the dipyridamole/basal coronary sinus blood flow ratio (D/B CSBF) and the coronary resistance reserve by the dipyridamole/basal coronary resistance ratio (D/B CR). Coronary reserve was greatly impaired in the group with primary scleroderma myocardial disease: D/B CSBF was lower than in the control group (2.54 +/- 1.37 vs 4.01 +/- 0.56, respectively; p less than 0.05) and D/B CR was higher than in the control group (0.47 +/- 0.25 vs 0.23 +/- 0.04, respectively; p less than 0.05). Such a decreased coronary flow and resistance reserve in patients with primary scleroderma myocardial disease was not explained by an alteration of left ventricular function. It may be an important contributing factor in the pathogenesis of primary scleroderma myocardial disease

  1. The materials flow of mercury in the economies of the United States and the world

    Science.gov (United States)

    Sznopek, John L.; Goonan, Thomas G.

    2000-01-01

    Although natural sources of mercury exist in the environment, measured data and modeling results indicate that the amount of mercury released into the biosphere has increased since the beginning of the industrial age. Mercury is naturally distributed in the air, water, and soil in minute amounts, and can be mobile within and between these media. Because of these properties and the subsequent impacts on human health, mercury was selected for an initial materials flow study, focusing on the United States in 1990. This study was initiated to provide a current domestic and international analysis. As part of an increased emphasis on materials flow, this report researched changes and identified the associated trends in mercury flows; it also updates statistics through 1996. In addition to domestic flows, the report includes an international section, because all primary mercury-producing mines are currently foreign, 86 percent of the mercury cell sector of the worldwide chlor-alkali industry is outside the United States, there is a large international mercury trade (1,395 t 1 in 1996), and environmental regulations are not uniform or similarly enforced from country to country. Environmental concerns have brought about numerous regulations that have dramatically decreased both the use and the production of mercury since the late 1980?s. Our study indicates that this trend is likely to continue into the future, as the world eliminates the large mercury inventories that have been stockpiled to support prior industrial processes and products.

  2. Primary tetralogy of Fallot repair: predictors of intensive care unit morbidity.

    Science.gov (United States)

    Egbe, Alexander C; Uppu, Santosh C; Mittnacht, Alexander J C; Joashi, Umesh; Ho, Deborah; Nguyen, Khanh; Srivastava, Shubhika

    2014-09-01

    Primary repair of tetralogy of Fallot has low surgical mortality, but some patients still experience significant postoperative morbidity. Our objectives were to review our institutional experience with primary tetralogy of Fallot repair, and identify predictors of intensive care unit morbidity. We reviewed all patients with tetralogy of Fallot who underwent primary repair in infancy from 2001 to 2012. Preoperative, operative, and postoperative demographic and morphologic data were analyzed. Intensive care unit morbidity was defined as prolonged intensive care unit stay (≥ 7 days) and/or prolonged duration of mechanical ventilation (≥ 48 h). 97 patients who underwent primary surgical repair during the study period were included in the study. The median age was 4.9 months (range 1-9 months) and the median weight was 5.3 kg (range 3.1-9.8 kg). There was no early surgical mortality. The incidence of junctional ectopic tachycardia and persistent complete heart block was 2% and 1%, respectively. The median intensive care unit stay was 6 days (range 2-21 days) and the median duration of mechanical ventilation was 19 h (range 0-136 h). Age and weight were independent predictors of intensive care unit stay, while surgical era predicted the duration of mechanical ventilation. Primary tetralogy of Fallot repair is a safe procedure with low mortality and morbidity in a medium-sized program with outcomes comparable to national standards. Age and weight at the time of surgery were significant predictors of morbidity. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Simulation-based patient flow analysis in an endoscopy unit

    DEFF Research Database (Denmark)

    Koo, Pyung-Hoi; Nielsen, Karl Brian; Jang, Jaejin

    2010-01-01

    One of the major elements in improving efficiency of healthcare services is patient flow. Patients require a variety of healthcare resources as they receive healthcare services. Poor management of patient flow results in long waiting time of patients, under/over utilization of medical resources......, low quality of care and high healthcare cost. This article addresses patient flow problems at a Gastrointestinal endoscopy unit. We attempt to analyze the main factors that contribute to the inefficient patient flow and process bottlenecks and to propose efficient patient scheduling and staff...

  4. On Tour... Primary Hardwood Processing, Products and Recycling Unit

    Science.gov (United States)

    Philip A. Araman; Daniel L. Schmoldt

    1995-01-01

    Housed within the Department of Wood Science and Forest Products at Virginia Polytechnic Institute is a three-person USDA Forest Service research work unit (with one vacancy) devoted to hardwood processing and recycling research. Phil Araman is the project leader of this truly unique and productive unit, titled ãPrimary Hardwood Processing, Products and Recycling.ä The...

  5. Engine Tune-Up Service. Unit 3: Primary Circuit. Posttests. Automotive Mechanics Curriculum.

    Science.gov (United States)

    Morse, David T.

    This book of posttests is designed to accompany the Engine Tune-Up Service Student Guide for Unit 3, Primary Circuit, available separately as CE 031 211. Focus of the posttests is setting the primary ignition circuit. One multiple choice posttest is provided, covering the eight performance objectives contained in the unit. (No answer key is…

  6. Back-flow ripples in troughs downstream of unit bars: Formation, preservation and value for interpreting flow conditions

    OpenAIRE

    Herbert, Christopher; Alexander, Jan; Martinez De Alvaro, Maria

    2015-01-01

    Back-flow ripples are bedforms created within the lee-side eddy of a larger bedform with migration directions opposed or oblique to that of the host bedform. In the flume experiments described in this article, back-flow ripples formed in the trough downstream of a unit bar and changed with mean flow velocity; varying from small incipient back-flow ripples at low velocities, to well-formed back-flow ripples with greater velocity, to rapidly migrating transient back-flow ripples formed at the g...

  7. Vibration-accelerated activation of flow units in a Pd-based bulk metallic glass

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ning, E-mail: hslining@mail.hust.edu.cn [School of Materials Science and Engineering, and State Key Laboratory of Material Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Liu, Ze [Department of Engineering Mechanics, School of Civil Engineering, Wuhan University, Wuhan 430072 (China); Wang, Xinyun [School of Materials Science and Engineering, and State Key Laboratory of Material Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Zhang, Meng [Institute of Advanced Wear & Corrosion Resistant and Functional Materials, Jinan University, Guangzhou 510632 (China)

    2017-04-24

    Controlled activation of flow units and in-situ characterization of mechanical properties in metallic glasses are facing challenges thus far. Here, vibrational loading is introduced through nanoscale dynamic mechanical analysis technique to probe vibration-accelerated atomic level flow that plays a crucial role in the mechanical behavior of metallic glasses. The intriguing finding is that high vibrational frequency induces deep indentation depth, prominent pop-in events on load–depth curves and low storage modulus, exhibiting a vibration-facilitated activation of flow units in Pd{sub 40}Cu{sub 30}Ni{sub 10}P{sub 20} metallic glass. Theoretical analysis revealed that vibration-moderated activation time-scale accelerate the activation of flow units and responsible for the above scenario.

  8. Regional cerebral blood flow in primary degenerative dementia

    International Nuclear Information System (INIS)

    Kawakatsu, Shinobu; Totsuka, Shiro; Shinohara, Masao; Koyama, Hideki; Sagawa, Katsuo; Morinobu, Shigeru; Oiji, Arata; Komatani, Akio

    1991-01-01

    Regional cerebral blood flow (rCBF) was examined, using SPECT by Xe-133 inhalation, in patients with primary degenerative dementia who were subgrouped according to predominant symptoms with respect to amnesia, apraxia, agnosia, aphasia, and personality changes. Also the effect of sex and age at dementia onset on the rCBF patterns was assessed. (author). 26 refs.; 1 fig.; 7 tabs

  9. A laminar flow unit for the care of critically ill newborn infants

    Directory of Open Access Journals (Sweden)

    Perez JM

    2013-10-01

    Full Text Available Jose MR Perez,1 Sergio G Golombek,2 Carlos Fajardo,3 Augusto Sola41Stella Maris Hospital, International Neurodevelopment Neonatal Center (CINN, Sao Paulo, Brazil; 2M Fareri Children’s Hospital, Westchester Medical Center, New York Medical College, Valhalla, NY, USA; 3University of Calgary, Calgary, Canada; 4St Jude Hospital, Fullerton, California, CA, USAIntroduction: Medical and nursing care of newborns is predicated on the delicate control and balance of several vital parameters. Closed incubators and open radiant warmers are the most widely used devices for the care of neonates in intensive care; however, several well-known limitations of these devises have not been resolved. The use of laminar flow is widely used in many fields of medicine, and may have applications in neonatal care.Objective: To describe the neonatal laminar flow unit, a new equipment we designed for care of ill newborns.Methods: The idea, design, and development of this device was completed in Sao Paulo, Brazil. The unit is an open mobile bed designed with the objective of maintaining the advantages of the incubator and radiant warmer, while overcoming some of their inherent shortcomings; these shortcomings include noise, magnetic fields and acrylic barriers in incubators, and lack of isolation and water loss through skin in radiant warmers. The unit has a pump that aspirates environmental air which is warmed by electrical resistance and decontaminated with High Efficiency Particulate Air Filter (HEPA filters (laminar flow. The flow is directed by an air flow directioner. The unit has an embedded humidifier to increase humidity in the infant’s microenvironment and a servo control mechanism for regulation of skin temperature.Results: The laminar flow unit is open and facilitates access of care providers and family, which is not the case in incubators. It provides warming by convection at an air velocity of 0.45 m/s, much faster than an incubator (0.1 m/s. The system

  10. Detection of primary coolant leaks in NPP

    International Nuclear Information System (INIS)

    Slavov, S.; Bakalov, I.; Vassilev, H.

    2001-01-01

    The thermo-hydraulic analyses of the SG box behaviour of Kozloduy NPP units 3 and 4 in case of small primary circuit leaks and during normal operation of the existing ventilation systems in order to determine the detectable leakages from the primary circuit by analysing different parameters used for the purposes of 'Leak before break' concept, performed by ENPRO Consult Ltd. are presented. The following methods for leak detection: measurement of relative air humidity in SG box (can be used for detection of leaks with flow rate 3.78 l/min within one hour at ambient parameters - temperature 40 0 - 60 0 C and relative humidity form 30% to 60%); measurement of water level in SG box sumps (can not be used for reliable detection of small primary circuit leakages with flow rate about 3.78 l/min); measurement of gaseous radioactivity in SG box( can be used as a general global indication for detection of small leakages from the primary circuit); measurement of condensate flow after the air coolers of P-1 venting system (can be used for primary circuit leak detection) are considered. For determination of the confinement behaviour, a model used with computer code MELCOR has been developed by ENPRO Consult Ltd. A brief summary based on the capabilities of the different methods of leak detection, from the point of view of the applicability of a particular method is given. For both Units 3 and 4 of Kozloduy NPP a qualified complex system for small leak detection is planned to be constructed. Such a system has to unite the following systems: acoustic system for leak detection 'ALUS'; system for control of the tightness of the main primary circuit pipelines by monitoring the local humidity; system for primary circuit leakage detection by measuring condensate run-off in collecting tank after ventilation system P-1 air coolers

  11. Sri Lanka's Health Unit Program: A Model of "Selective" Primary Health Care

    Directory of Open Access Journals (Sweden)

    Soma Hewa

    2011-12-01

    Full Text Available This paper argues that the health unit program developed in Sri Lanka in the early twentieth century was an earlier model of selective primary health care promoted by the Rockefeller Foundation in the 1980s in opposition to comprehensive primary health care advocated by the Alma-Ata Declaration of the World Health Organization. A key strategy of the health unit program was to identify the most common and serious infectious diseases in each health unit area and control them through improved sanitation, health education, immunization and treatment with the help of local communities. The health unit program was later introduced to other countries in South and Southeast Asia as part of the Rockefeller Foundation's global campaign to promote public health.

  12. Stability of Armour Units in Flow Through a Layer

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; C. Thompson, Alex

    1984-01-01

    As part of a program to study the hydraulics of wave attack on rubble mound breakwaters tests were made on model armour units in a steady flow through a layer laid on a slope. The flow angle has little effect on stability for dolosse or rock layers. The head drop at failure across each type...... of layer is similar but the dolosse layer is more permeable and fails as a whole. There was no viscous scale effect. These results and earlier tests in oscillating flow suggest a 'reservoir' effect is important in the stability in steep waves....

  13. Compositional variation within thick (>10 m) flow units of Mauna Kea Volcano cored by the Hawaii Scientific Drilling Project

    Science.gov (United States)

    Huang, Shichun; Vollinger, Michael J.; Frey, Frederick A.; Rhodes, J. Michael; Zhang, Qun

    2016-07-01

    Geochemical analyses of stratigraphic sequences of lava flows are necessary to understand how a volcano works. Typically one sample from each lava flow is collected and studied with the assumption that this sample is representative of the flow composition. This assumption may not be valid. The thickness of flows ranges from 100 m. Geochemical heterogeneity in thin flows may be created by interaction with the surficial environment whereas magmatic processes occurring during emplacement may create geochemical heterogeneities in thick flows. The Hawaii Scientific Drilling Project (HSDP) cored ∼3.3 km of basalt erupted at Mauna Kea Volcano. In order to determine geochemical heterogeneities in a flow, multiple samples from four thick (9.3-98.4 m) HSDP flow units were analyzed for major and trace elements. We found that major element abundances in three submarine flow units are controlled by the varying proportion of olivine, the primary phenocryst phase in these samples. Post-magmatic alteration of a subaerial flow led to loss of SiO2, CaO, Na2O, K2O and P2O5, and as a consequence, contents of immobile elements, such as Fe2O3 and Al2O3, increase. The mobility of SiO2 is important because Mauma Kea shield lavas divide into two groups that differ in SiO2 content. Post-magmatic mobility of SiO2 adds complexity to determining if these groups reflect differences in source or process. The most mobile elements during post-magmatic subaerial and submarine alteration are K and Rb, and Ba, Sr and U were also mobile, but their abundances are not highly correlated with K and Rb. The Ba/Th ratio has been used to document an important role for a plagioclase-rich source component for basalt from the Galapagos, Iceland and Hawaii. Although Ba/Th is anomalously high in Hawaiian basalt, variation in Ba abundance within a single flow shows that it is not a reliable indicator of a deep source component. In contrast, ratios involving elements that are typically immobile, such as La/Nb, La

  14. Off-wall boundary conditions for turbulent flows obtained from buffer-layer minimal flow units

    Science.gov (United States)

    Garcia-Mayoral, Ricardo; Pierce, Brian; Wallace, James

    2012-11-01

    There is strong evidence that the transport processes in the buffer region of wall-bounded turbulence are common across various flow configurations, even in the embryonic turbulence in transition (Park et al., Phys. Fl. 24). We use this premise to develop off-wall boundary conditions for turbulent simulations. Boundary conditions are constructed from DNS databases using periodic minimal flow units and reduced order modeling. The DNS data was taken from a channel at Reτ = 400 and a zero-pressure gradient transitional boundary layer (Sayadi et al., submitted to J . FluidMech .) . Both types of boundary conditions were first tested on a DNS of the core of the channel flow with the aim of extending their application to LES and to spatially evolving flows. 2012 CTR Summer Program.

  15. Engine Tune-Up Service. Unit 3: Primary Circuit. Student Guide. Automotive Mechanics Curriculum.

    Science.gov (United States)

    Bacon, E. Miles

    This student guide is for Unit 3, Primary Circuit, in the Engine Tune-Up Service portion of the Automotive Mechanics Curriculum. It deals with how to test the primary ignition circuit. A companion review exercise book and posttests are available separately as CE 031 212-213. An introduction tells how this unit fits into the total tune-up service,…

  16. Theoretical investigations on the determination of cavitation-free primary flow after compacting the reactor FRG-1

    International Nuclear Information System (INIS)

    Pihowicz, W.

    1997-01-01

    Basing on an extensive analysis of the influence of compacting the FRG-1 reactor core upon the change in flow, heat exchange, as well as cavitation behavior of the primary circuit the underlying principles of the determination procedure for a cavitations-free primary flow have been developed theoretically. It was found that the problem has to be treated in a complex manner, i.e. considering the coupled flow, temperature, as well as cavitation fields, and that for a successful solution of the problem it is absolutely necessary to simultaneously induce an optimized fixation of the main primary coolant pump. (orig.) [de

  17. Stability of Armour Units in Oscillatory Flow

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Thompson, A. C.

    Despite numerous breakwater model tests very little is known today about the various phenomena and parameters that determine the hydraulic stability characteristics of different types of armour. This is because separation of parameters is extremely difficult in traditional tests.With the object...... of separating some of the factors a deterministic test, in which horizontal beds of armour units were exposed to oscillatory flow, was performed in a pulsating water tunnel....

  18. Process and system for stirring liquid sodium flowing through the primary circuit of a steam generator

    International Nuclear Information System (INIS)

    Fabregue, J.P.

    1982-01-01

    The invention concerns the stirring of the liquid sodium of a steam generator comprising a primary circuit composed of an elongated vessel through which the liquid sodium flows, a secondary circuit composed of a number of tubes extending inside the long cyclindrical vessel. The process consists in imparting simultaneously to the liquid sodium, during its passage through the cylindrical vessel, a movement of continuous rotation about the longitudinal axis of the cylindrical vessel and an alternating series of radial movements, centripetal and centrifugal, in relation to the longitudinal axis, so that each unit quantity of the sodium comes into contact with a large number of tubes. The application particularly concerns steam generators for nuclear power stations [fr

  19. Combustor with two stage primary fuel tube with concentric members and flow regulating

    Science.gov (United States)

    Parker, David Marchant; Whidden, Graydon Lane; Zolyomi, Wendel

    1999-01-01

    A combustor for a gas turbine having a centrally located fuel nozzle and inner, middle and outer concentric cylindrical liners, the inner liner enclosing a primary combustion zone. The combustor has an air inlet that forms two passages for pre-mixing primary fuel and air to be supplied to the primary combustion zone. Each of the pre-mixing passages has a circumferential array of swirl vanes. A plurality of primary fuel tube assemblies extend through both pre-mixing passages, with each primary fuel tube assembly located between a pair of swirl vanes. Each primary fuel tube assembly is comprised of two tubular members. The first member supplies fuel to the first pre-mixing passage, while the second member, which extends through the first member, supplies fuel to the second pre-mixing passage. An annular fuel manifold is divided into first and second chambers by a circumferentially extending baffle. The proximal end of the first member is attached to the manifold itself while the proximal end of the second member is attached to the baffle. The distal end of the first member is attached directly to the second member at around its mid-point. The inlets of the first and second members are in flow communication with the first and second manifold chambers, respectively. Control valves separately regulate the flow of fuel to the two chambers and, therefore, to the two members of the fuel tube assemblies, thereby allowing the flow of fuel to the first and second pre-mixing passages to be separately controlled.

  20. Human appropriation of net primary production in the United Kingdom, 1800-2000. Changes in society's impact on ecological energy flows during the agrarian-industrial transition

    International Nuclear Information System (INIS)

    Musel, Annabella

    2009-01-01

    This paper presents an empirical analysis of the United Kingdom's society's long-term intervention into the energy flows of domestic terrestrial ecosystems through the human appropriation of aboveground net primary production (aHANPP) covering the period 1800-2000. The depicted aHANPP trajectory and the historical development of its components are discussed in view of a continuously increasing population and the transition process from an agrarian to an industrial socioecological regime. During the 19th century, aHANPP shows a steady decline from its level of 71% in 1800. While even higher levels were reached during the mid 20th century, the trend during the last forty years of the period under investigation again shows a reduction of aHANPP, which lies at 68% in the year 2000. The high values of aHANPP in the United Kingdom are primarily attributable to the limited amount of forest in comparison to large agricultural areas. At the beginning of the studied period, the relative stabilisation or even decrease in aHANPP in comparison to population development was made possible through the area expansion of and productivity increases on cropland and permanent pastures. Later this was made possible through the outsourcing of biomass harvest, by satisfying local nutritional demands by means of overseas imports, and as from the mid 20th century through huge amounts of fossil fuel based inputs into agriculture (e.g. increased amounts of fertilizers and motorized traction) which allowed increases in biomass harvest to be decoupled from HANPP. (author)

  1. Performance study of ejector cooling cycle at critical mode under superheated primary flow

    International Nuclear Information System (INIS)

    Tashtoush, Bourhan; Alshare, Aiman; Al-Rifai, Saja

    2015-01-01

    Highlights: • The ECC is modeled using EES Software and it is validated with published data. • Detailed analysis of the ECC with different refrigerants is conducted. • The constant pressure mixing is better than constant area mixing ejectors. • R134a is the selected refrigerant for the best cooling cycle performance. • The superheated primary flow at critical mode is achieved with EJ2 ejector used. - Abstract: In this work the performance of the ejector cooling cycle is investigated at critical mode, where, the effects of ejector geometry, refrigerant type, and operating condition are studied. The ejector cooling cycle is modeled with EES Software. The mass, momentum, and energy conservation principles are applied to the secondary and primary flows to investigate the performance of the ejector cooling cycle under superheated primary flow. The refrigerant R134 a is selected based on the merit of its environmental and performance characteristics. The primary working fluid in the refrigeration cycle is maintained at superheated conditions for optimal ejector performance. The solar generator temperature ranges are 80–100 °C. The operating temperature of evaporator range is 8–12 °C and the optimal condensation temperature is in the range of 28–40 °C. It is found that constant-pressure mixing ejector generates higher backpressure than constant-area mixing ejector for the same entrainment ratio and COP. The type of ejector is selected based on the performance criteria of the critical backpressure and choking condition of the primary flow, the so called EJ2 type ejector meets the criteria. The COP is found to be in the range of 0.59–0.67 at condenser backpressure of 24 bar due to higher critical condenser pressure and higher generator temperature

  2. Evaluation of a technology unit in a girls' primary school

    Science.gov (United States)

    Eke, Marion; Gardner, Paul L.

    1991-12-01

    Rapid advances in technology are changing the structure of the workforce. There are elite highly-paid hi-tech occupations and low status poorly-paid jobs. Women are unfortunately more likely to be found in the latter category. To allow them to qualify and compete for the higher-status positions, girls need to participate in the physical sciences and in technology studies. However, they are rarely attracted to them in secondary school, possibly because they are already alienated from them by the time they leave primary school. This paper reports some of the outcomes of a curriculum unit taught in two primary school classes in an independent school for girls. The unit was cross-curricular, involving technology, science and other fields of knowledge; it made extensive use of LEGO Technic materials. The evaluation of the unit, based on observations, a teacher journal and pupil questionnaires, focussed upon the issue of whether it assisted the girls to feel happier about working with unfamiliar technology and feel more capable of doing so. Implications for teaching technology are also discussed.

  3. Phase II Hydrologic Data for the Groundwater Flow and Contaminant Transport Model of Corrective Action Unit 98: Frenchman Flat, Nye County, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    John McCord

    2004-12-01

    This report documents pertinent hydrologic data and data analyses as part of the Phase II Corrective Action Investigation (CAI) for Frenchman Flat (FF) Corrective Action Unit (CAU): CAU 98. The purpose of this data compilation and related analyses is to provide the primary reference to support the development of the Phase II FF CAU groundwater flow model.

  4. Efficiency of the pre-heater against flow rate on primary the beta test loop

    International Nuclear Information System (INIS)

    Edy Sumarno; Kiswanta; Bambang Heru; Ainur R; Joko P

    2013-01-01

    Calculation of efficiency of the pre-heater has been carried out against the flow rate on primary the BETA Test Loop. BETA test loop (UUB) is a facilities of experiments to study the thermal hydraulic phenomenon, especially for thermal hydraulic post-LOCA (Lost of Coolant Accident). Sequences removal on the BETA Test Loop contained a pre-heater that serves as a getter heat from the primary side to the secondary side, determination of efficiency is to compare the incoming heat energy with the energy taken out by a secondary fluid. Characterization is intended to determine the performance of a pre-heater, then used as tool for analysis, and as a reference design experiments. Calculation of efficiency methods performed by operating the pre-heater with fluid flow rate variation on the primary side. Calculation of efficiency on the results obtained that the efficiency change with every change of flow rate, the flow rate is 71.26% on 163.50 ml/s and 60.65% on 850.90 ml/s. Efficiency value can be even greater if the pre-heater tank is wrapped with thermal insulation so there is no heat leakage. (author)

  5. FDG metabolism and uptake versus blood flow in women with untreated primary breast cancers

    International Nuclear Information System (INIS)

    Zasadny, Kenneth R.; Tatsumi, Mitsuaki; Wahl, Richard L.

    2003-01-01

    The aim of this study was to determine the relationship between tumor blood flow and glucose utilization in women with untreated primary breast carcinomas. Noninvasive determinations of blood flow and glucose utilization with positron emission tomography (PET) were performed in 101 regions of tumor from nine women with untreated primary breast carcinoma. [ 15 O]H 2 O PET scans of tumor blood flow were compared with fluorine-18 fluoro-2-deoxy-D-glucose (FDG) PET scans of tumor glucose metabolism. Modeling of multiple parameters was undertaken and flow and glucose utilization compared. Mean whole-tumor blood flow was 14.9 ml dl -1 min -1 , but ranged from 7.6 to 29.2 ml dl -1 min -1 . Mean whole-tumor standardized uptake value corrected for lean body mass, SUV-lean (50-60 min), was 2.32±0.19 while mean K i was 1.2 ml dl -1 min -1 for FDG. SUV-lean and blood flow were strongly correlated (r=0.82, P=0.007) as were K 1 for FDG and flow (r=0.84, P=0.004). In these women with untreated breast cancers, FDG uptake (SUV-lean) and tumor blood flow are strongly correlated. The slope of FDG uptake versus blood flow appears higher at low flow rates, suggesting the possible presence of areas of tumor hypoxia. (orig.)

  6. Modeling and design of a combined transverse and axial flow threshing unit for rice harvesters

    Directory of Open Access Journals (Sweden)

    Zhong Tang

    2014-11-01

    Full Text Available The thorough investigation of both grain threshing and grain separating processes is a crucial consideration for effective structural design and variable optimization of the tangential flow threshing cylinder and longitudinal axial flow threshing cylinder composite units (TLFC unit of small and medium-sized (SME combine harvesters. The objective of this paper was to obtain the structural variables of a TLFC unit by theoretical modeling and experimentation on a tangential flow threshing cylinder unit (TFC unit and longitudinal axial flow threshing cylinder unit (LFC unit. Threshing and separation equations for five types of threshing teeth (knife bar, trapezoidal tooth, spike tooth, rasp bar, and rectangular bar, were obtained using probability theory. Results demonstrate that the threshing and separation capacity of the knife bar TFC unit was stronger than the other threshing teeth. The length of the LFC unit was divided into four sections, with helical blades on the first section (0-0.17 m, the spike tooth on the second section (0.17-1.48 m, the trapezoidal tooth on the third section (1.48-2.91 m, and the discharge plate on the fourth section (2.91-3.35 m. Test results showed an un-threshed grain rate of 0.243%, un-separated grain rate of 0.346%, and broken grain rate of 0.184%. Evidenced by these results, threshing and separation performance is significantly improved by analyzing and optimizing the structure and variables of a TLFC unit. The results of this research can be used to successfully design the TLFC unit of small and medium-sized (SME combine harvesters.

  7. Use of primary care data for detecting impetigo trends, United kingdom, 1995-2010.

    Science.gov (United States)

    Shallcross, Laura J; Petersen, Irene; Rosenthal, Joe; Johnson, Anne M; Freemantle, Nick; Hayward, Andrew C

    2013-10-01

    Using a primary care database, we identified a major increase in impetigo in the United Kingdom during 1995-2010. Despite a doubled rate of primary care consultations, this increase was not identified by routine surveillance. Primary care databases are a valuable and underused source of surveillance data on infectious diseases.

  8. Numerical simulation of the flow around a steerable propulsion unit

    International Nuclear Information System (INIS)

    Pacuraru, F; Lungu, A; Ungureanu, C; Marcu, O

    2010-01-01

    Azimuth propulsion units have become during the last decade a more and more popular solution for all kinds of vessels. Azimuth thruster system, combining the propulsion and steering units of conventional ships replaces traditional propellers and lengthy drive shafts and rudders ensuring an excellent vessel steering. In many cases the interaction between the propeller and other components of the propulsion system strongly affects the inflow to the propeller and therefore its performance. The correct estimation of this influence is important for propulsion systems which consist of more than one element, such as pods (shaft, gondola and propeller), ducted propellers (duct, struts and propeller) or bow thrusters (ship form, tunnel, gondola and propeller). The paper proposes a numerical investigation based on RANS computation for solving the viscous flow around an azimuth thruster system to provide a detailed insight into the critical flow regions for determining the optimum inclination angle for struts, for studying the hydrodynamic interactions between various components of the system, for predicting the hydrodynamic performance of the propulsion system and to investigate regions with possible flow separations.

  9. Two-phase flow degradation on Fukushima-Daiichi Unit 2 RCIC turbine performance

    International Nuclear Information System (INIS)

    Lopez, Hector; Erkan, Nejdet; Okamoto, Koji

    2016-01-01

    After the Fukushima accident, several investigation reports, including experiments and simulations have been done for each of the affected units to completely understand the accident progression and use their results to improve the knowledge of severe accident management and the severe codes performance. In Unit 2, the major uncertainties are related with the reactor core isolation cooling (RCIC) system performance during the accident progression especially focused in the RCIC turbine, which is assumed to work in two-phase flow. The main objective of this study is to analyze the RCIC turbine performance under two-phase flow scenarios under the assumption that the power produced by the turbine is lower than expected due to the liquid phase in the flow. A degradation coefficient quantifying the turbine power reduction is developed as a function of the flow quality by using the sonic speed reduction at critical flow conditions principle obtained by applying the non-homogeneous equilibrium model (NHEM). The degradation coefficient was applied to RELAP/ScdapSIM severe accident code showing a drastic reduction of the turbine-generated power during two-phase flow and obtaining a RCIC system behavior closer to the Tokyo electric power company (TEPCO) investigation report conclusions. (author)

  10. Response of EBR-II to a complete loss of primary forced flow during power operation

    International Nuclear Information System (INIS)

    Singer, R.M.; Gillette, J.L.; Mohr, D.; Tokar, J.V.; Sullivan, J.E.; Dean, E.M.

    1980-01-01

    Detailed measurements of the thermal, hydraulic, and neutronic response of EBR-II to a complete loss of primary forced flow followed by a PPS-activated scram are presented. The experimental results clearly indicate a smooth transition to natural convective flow with a quite modest incore temperature transient. The accompanying calculations using the NATDEMO code agree quite well with the measured temperatures and flow rates throughout the primary system. The only region of the plant where a significant discrepancy between the measurements and calculations occurred was in the IHX. The reasons for this result could not be definitively determined, but it is speculated that the one-dimensional assumptions used in the modeling may not be valid in the IHX during buoyancy driver flows

  11. An efficient continuous flow helium cooling unit for Moessbauer experiments

    International Nuclear Information System (INIS)

    Herbert, I.R.; Campbell, S.J.

    1976-01-01

    A Moessbauer continuous flow cooling unit for use with liquid helium over the temperature range 4.2 to 300K is described. The cooling unit can be used for either absorber or source studies in the horizontal plane and it is positioned directly on top of a helium storage vessel. The helium transfer line forms an integral part of the cooling unit and feeds directly into the storage vessel so that helium losses are kept to the minimum. The helium consumption is 0.12 l h -1 at 4.2 K decreasing to 0.055 l h -1 at 40 K. The unit is top loading and the exchange gas cooled samples can be changed easily and quickly. (author)

  12. Differences between rural and urban primary care units in Turkey: Implications on residents′ training

    Directory of Open Access Journals (Sweden)

    Hulya Yikilkan

    2013-01-01

    Full Text Available Context: Family practice training takes place at primary care based training centers linked to Education and Research State Hospitals in Turkey. There is a discussion if these units are adequate to train primary care staff and if the patients of these units reflect the applicants of primary care. Aims: The aim of our study is to investigate the demographic characteristics, the effect of distance on primary care utilization, and most common diagnosis of the patients who applied to two different outpatient clinics: One urban and one rural. Settings and Design: Study was conducted from the electronic health records of the patients applied to outpatient clinics of Ankara Diskapi Yildirim Beyazit Training and Research Hospital Department of Family Medicine between 1 January and 31 December 2009. Results: Total number of patients applied to both of the outpatient clinics was 34,632 [urban clinic: 16.506 (47.7%, rural clinic: 18.126 (52.3%]. Leading three diagnoses were upper respiratory tract infection (URTI, general medical examination (GME, and hypertension (HT in the most common 10 diagnosis. Conclusion: In our study, the rural outpatient clinic is regarded as a primary care unit in the neighborhood of living area and the urban clinic as close to working environment. We found statistically meaningful differences in most common diagnosis, gender, age, and consultation time between the rural and urban clinics. According to our results, family practitioners′ field training should take place at different primary care units according to sociodemographic characteristics of each country.

  13. Primary system hydraulic characteristics after modification of reactor coolant pumps' impeller wheels at Bohunice NPP executed in 2012 and 2013

    International Nuclear Information System (INIS)

    Hermansky, Jozef; Zavodsky, Martin

    2014-01-01

    A coolant flow through the reactor is usually determined after annual outages at Slovak NPP (VVER 440) in two distinct ways. First method is determination on the basis of the secondary system parameters - measurement of thermal balances. The value achieved by this method is used as the input parameter in the Table of allowed reactor operation modes. The second method draws from the primary system parameters - measurement of primary system hydraulic characteristics. Flow nozzles used for the measurement of feed water flow behind high pressure heaters were replaced at both Bohunice Units during outages in 2008. The feed water flow behind high pressure heaters is one of the main parameters used for the determination of coolant flow through the reactor by the first method. Compared to the measurement executed during previous fuel cycles, the calculated coolant flow through the reactor decreased considerably after the change of flow nozzles. The imaginary change of coolant flow through the reactor at Unit 3 was -1,6 %; and at Unit 4 -2,6 %. This change was not proved by the parallel measurement of primary system hydraulic characteristics. Later it was found out that the original flow nozzles used for 25 years were substantially deposited (original inner diameter of the nozzles was reduced by about 0,6-0,9 mm). Therefore feed water flow measurement was untrustworthy within the recent years. On the findings stated above, Bohunice NPP has decided to increase coolant flow through the reactor by changing the reactor coolant pumps impeller wheels. The modification of impellers wheels is planned within years 2012 to 2014. During the outages in 2013 two impeller wheels were replaced at both units. Nowadays Unit 4 is operated with all 6 new impeller wheels and Unit 3 with four new impeller wheels. Modification of last two impeller wheels at Unit 3 will be performed during the outage in 2014. On account of impeller wheels modification, non-standard measurement of PS hydraulic

  14. Bone and bone-marrow blood flow in chronic granulocytic leukemia and primary myelofibrosis

    International Nuclear Information System (INIS)

    Lahtinen, R.; Lahtinen, T.; Romppanen, T.

    1982-01-01

    Blood flow in hematopoietic bone marrow and in nonhematopoietic bone has been measured with a Xe-133 washout method in 20 patients with chronic granulocytic leukemia (CGL) and in seven with primary myelofibrosis. Age-matched healthy persons served as controls. Bone-marrow blood flow in CGL was dependent upon the phase of the disease. In the metamorphosis phase, bone-marrow blood flow was high compared with that in the well-controlled phase. Apart from the initial phase, the mean values for bone blood flow in CGL were increased compared with the values of the healthy controls. In myelofibrosis the bone blood flow was also increased. Bone-marrow blood flow in these diseases was dependent upon the cellularity of bone marrow as measured morphometrically

  15. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit. 2. Flow characteristics of bubbly countercurrent flow

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu.

    1997-01-01

    The authors have developed a measurement system which is composed of an ultrasonic velocity profile monitor and a video data processing unit in order to clarify its multi-dimensional flow characteristics in bubbly flows and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system was applied for bubbly countercurrent flows in a vertical rectangular channel. At first, both bubble and water velocity profiles and void fraction profiles in the channel were investigated statistically. Next, turbulence intensity in a continuous liquid phase was defined as a standard deviation of velocity fluctuation, and the two-phase multiplier profile of turbulence intensity in the channel was clarified as a ratio of the standard deviation of flow fluctuation in a bubbly countercurrent flow to that in a water single phase flow. Finally, the distribution parameter and drift velocity used in the drift flux model for bubbly countercurrent flows were calculated from the obtained velocity profiles of both phases and void fraction profile, and were compared with the correlation proposed for bubbly countercurrent flows. (author)

  16. The primary cilium as sensor of fluid flow: new building blocks to the model

    DEFF Research Database (Denmark)

    Prætorius, Helle

    2015-01-01

    functionally as an organelle that makes cells more susceptible to changes in fluid flow. Thus the primary cilium was suggested to function as a flow-sensing device. This characterization has been substantiated for many epithelial cell types over the years. Nevertheless, part of the central mechanism of signal...

  17. Reactor core flow measurements during plant start-up using non-intrusive flow meter CROSSFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, V.; Sharp, B.; Gurevich, A., E-mail: vkanda@amag-inc.com, E-mail: bsharp@amag-inc.com, E-mail: agurevich@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada); Gurevich, Y., E-mail: yuri.gurevich@daystartech.ca [Daystar Technologies Inc., Ontario (Canada); Selvaratnarajah, S.; Lopez, A., E-mail: sselvaratnarajah@amag-inc.com, E-mail: alopez@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada)

    2013-07-01

    For the first time, direct measurements of the total reactor coolant flow and the flow distribution between the inner reactor zone and the outer zone were conducted using the non-intrusive clamp on ultrasonic cross-correlation flow meter, CROSSFLOW, developed and manufactured by Advanced Measurement & Analysis Group Inc. (AMAG). The measurements were performed at Bruce Power A Unit 1 on the Pump Discharge piping of the Primary Heat Transport (PHT) system during start-up. This paper describes installation processes, hydraulic testing, uncertainty analysis and traceability of the measurements to certified standards. (author)

  18. The reality of waste management in primary health care units in Brazil.

    Science.gov (United States)

    Alves, Sergiane B; e Souza, Adenícia C S; Tipple, Anaclara F V; Rezende, Keyti C A D; de Resende, Fabiana R; Rodrigues, Érika G; Pereira, Milca S

    2014-09-01

    A large number of users are serviced in primary health care units in Brazil, both in health facilities and in households. These services generate waste that must be managed safely, but there is no legislation that regulates this type of waste management in Brazil. The objective of this study was to analyse the production and management of waste in primary health care. A direct observation was performed of the stages in the handling and weighing of waste generated in primary health care units in the municipality of Goiânia (Brazil). The units generated infectious, chemical, and common waste, as well as sharp objects. The generation of waste ranged between 0.027 and 0.075 kg user-day. The generated waste was classified mostly as common and recyclable. Flaws were observed in the management of all types of waste. The critical point is segregation. Only 34.1% of the waste disposed of as infectious actually belonged to this group, the rest was ordinary waste. Flaws at this stage increase the volume of infectious waste, the occupational and environmental risks, and associated costs. Intervention to change this reality is needed and it requires the careful preparation of a waste management plan, corroborating structural changes to the implementation of this plan, and professional training and public policies to guide waste management in primary care, especially those generated in households. © The Author(s) 2014.

  19. Evaluating renewable natural resources flow and net primary productivity with a GIS-Emergy approach: A case study of Hokkaido, Japan.

    Science.gov (United States)

    Wang, Chengdong; Zhang, Shenyan; Yan, Wanglin; Wang, Renqing; Liu, Jian; Wang, Yutao

    2016-11-18

    Renewable natural resources, such as solar radiation, rainfall, wind, and geothermal heat, together with ecosystem services, provide the elementary supports for the sustainable development of human society. To improve regional sustainability, we studied the spatial distributions and quantities of renewable natural resources and net primary productivity (NPP) in Hokkaido, which is the second largest island of Japan. With the help of Geographic Information System (GIS) software, distribution maps for each type of renewable natural resource were generated by kriging interpolation based on statistical records. A composite map of the flow of all types of renewable natural resources was also generated by map layer overlapping. Additionally, we utilized emergy analysis to convert each renewable flow with different attributes into a unified unit (i.e., solar equivalent joules [sej]). As a result, the spatial distributions of the flow of renewable natural resources of the Hokkaido region are presented in the form of thematic emergy maps. Thus, the areas with higher renewable emergy can be easily visualized and identified. The dominant renewable flow in certain areas can also be directly distinguished. The results can provide useful information for regional sustainable development, environmental conservation and ecological management.

  20. Developing and Implementing a Mobile Conservation Education Unit for Rural Primary School Children in Lao PDR

    Science.gov (United States)

    Hansel, Troy; Phimmavong, Somvang; Phengsopha, Kaisone; Phompila, Chitana; Homduangpachan, Khiaosaphan

    2010-01-01

    In this article, the authors examine the implementation and success of a mobile conservation education unit targeting primary schools in central Lao PDR (People's Democratic Republic). The mobile unit conducted 3-hour interactive programs for school children focused on the importance of wildlife and biodiversity around the primary schools in rural…

  1. Human appropriation of net primary production in the United Kingdom, 1800-2000. Changes in society's impact on ecological energy flows during the agrarian-industrial transition

    Energy Technology Data Exchange (ETDEWEB)

    Musel, Annabella [Institute of Social Ecology, Alpen-Adria University Klagenfurt - Graz - Wien, Schottenfeldgasse 29, 1070 Vienna (Austria)

    2009-12-15

    This paper presents an empirical analysis of the United Kingdom's society's long-term intervention into the energy flows of domestic terrestrial ecosystems through the human appropriation of aboveground net primary production (aHANPP) covering the period 1800-2000. The depicted aHANPP trajectory and the historical development of its components are discussed in view of a continuously increasing population and the transition process from an agrarian to an industrial socioecological regime. During the 19th century, aHANPP shows a steady decline from its level of 71% in 1800. While even higher levels were reached during the mid 20th century, the trend during the last forty years of the period under investigation again shows a reduction of aHANPP, which lies at 68% in the year 2000. The high values of aHANPP in the United Kingdom are primarily attributable to the limited amount of forest in comparison to large agricultural areas. At the beginning of the studied period, the relative stabilisation or even decrease in aHANPP in comparison to population development was made possible through the area expansion of and productivity increases on cropland and permanent pastures. Later this was made possible through the outsourcing of biomass harvest, by satisfying local nutritional demands by means of overseas imports, and as from the mid 20th century through huge amounts of fossil fuel based inputs into agriculture (e.g. increased amounts of fertilizers and motorized traction) which allowed increases in biomass harvest to be decoupled from HANPP. (author)

  2. Installation of a Low Flow Unit at the Abiquiu Hydroelectric Facility

    Energy Technology Data Exchange (ETDEWEB)

    Jack Q. Richardson

    2012-06-28

    Final Technical Report for the Recovery Act Project for the Installation of a Low Flow Unit at the Abiquiu Hydroelectric Facility. The Abiquiu hydroelectric facility existed with two each 6.9 MW vertical flow Francis turbine-generators. This project installed a new 3.1 MW horizontal flow low flow turbine-generator. The total plant flow range to capture energy and generate power increased from between 250 and 1,300 cfs to between 75 and 1,550 cfs. Fifty full time equivalent (FTE) construction jobs were created for this project - 50% (or 25 FTE) were credited to ARRA funding due to the ARRA 50% project cost match. The Abiquiu facility has increased capacity, increased efficiency and provides for an improved aquatic environment owing to installed dissolved oxygen capabilities during traditional low flow periods in the Rio Chama. A new powerhouse addition was constructed to house the new turbine-generator equipment.

  3. The state of primary care in the United States of America and lessons for primary care groups in the United Kingdom.

    Science.gov (United States)

    Koperski, M

    2000-04-01

    The health care system of the United States of America (USA) is lavishly funded and those with adequate insurance usually receive excellent attention. However, the system is fragmented and inequitable. Health workers often find it difficult to separate vocational roles from business roles. Care tends to focus on the acute rather than the chronic, on 'episodes of illness' rather than 'person-centred' care, on short-term fixes rather than long-term approaches, on scientific/technical solutions rather than discourse or the 'art of healing', and on individual health rather than population health. The majority of US doctors are trained in the 'hightech' hospital paradigm and there is no equivalent of the United Kingdom (UK) general practitioner (GP), who lies at the hub of a primary health care team (PHCT) and who is charged with taking a long-term view, co-ordinating health care for individual patients, and acting as patient advocate without major conflicting financial incentives. However, primary care groups/trusts (PCGs) could learn from US management and training techniques, case management, NHS Direct equivalents, and the effects of poorly developed PHCTs. PCGs could develop the UK's own version of utilisation management. A cash-limited, unified budget within an underfunded National Health Service poses threats to general practice. In both the USA and the UK, primary care is a prominent tool in new attempts at cost control. PCGs offer the opportunity of better integration with public health and social services, but threaten GPs' role as independent advocates by giving them a rationing role. Managed care has forced a similar role onto our US counterparts with consequent public displeasure and professional disillusion. UK GPs will have to steer a careful course if they are to avoid a similar fate.

  4. Flow field measurements in the cell culture unit

    Science.gov (United States)

    Walker, Stephen; Wilder, Mike; Dimanlig, Arsenio; Jagger, Justin; Searby, Nancy

    2002-01-01

    The cell culture unit (CCU) is being designed to support cell growth for long-duration life science experiments on the International Space Station (ISS). The CCU is a perfused loop system that provides a fluid environment for controlled cell growth experiments within cell specimen chambers (CSCs), and is intended to accommodate diverse cell specimen types. Many of the functional requirements depend on the fluid flow field within the CSC (e.g., feeding and gas management). A design goal of the CCU is to match, within experimental limits, all environmental conditions, other than the effects of gravity on the cells, whether the hardware is in microgravity ( micro g), normal Earth gravity, or up to 2g on the ISS centrifuge. In order to achieve this goal, two steps are being taken. The first step is to characterize the environmental conditions of current 1g cell biology experiments being performed in laboratories using ground-based hardware. The second step is to ensure that the design of the CCU allows the fluid flow conditions found in 1g to be replicated from microgravity up to 2g. The techniques that are being used to take these steps include flow visualization, particle image velocimetry (PIV), and computational fluid dynamics (CFD). Flow visualization using the injection of dye has been used to gain a global perspective of the characteristics of the CSC flow field. To characterize laboratory cell culture conditions, PIV is being used to determine the flow field parameters of cell suspension cultures grown in Erlenmeyer flasks on orbital shakers. These measured parameters will be compared to PIV measurements in the CSCs to ensure that the flow field that cells encounter in CSCs is within the bounds determined for typical laboratory experiments. Using CFD, a detailed simulation is being developed to predict the flow field within the CSC for a wide variety of flow conditions, including microgravity environments. Results from all these measurements and analyses of the

  5. Management of Energy Flows in Low-temperature Separation Units

    Directory of Open Access Journals (Sweden)

    Trishyn F.A.

    2018-04-01

    Full Text Available . The aim of this work is to study the effect of medium and low power ultrasound on the crystallization and separation processes. A thesis about the importance of using thermal energy converters in separation units has been suggested. The prospects of desalination freezing units and ways of their improvement have been justified. Based on the system analysis, the energy flows in an ice recycling facility have been considered. For the first time, the overall energy efficiency estimation technique based on the hypothesis of direct and reverse energy flows has been proposed. The new results on the effect of ultrasonic fields on the separation and crystallization process have been obtained. It has been proved that the use of ultrasonic field is effective in controlling the energy flows during block freezing. It has been established that the salt content in the ice block is reduced by 2-3 times. The relationship between the ice block separation kinetics and the power and frequency has been determined. The similarity theory methods have been used to summarize the experimental data obtained. The criterion models have been presented to calculate the block porosity and the filtration rate. It has been established that the Euler wavenumber modified by the authors successfully generalizes the databases of the experimental findings. Using the numerical simulation methods, the thermal field in the block which depends on its porosity has been established. The results of the simulation have been presented in the form of a nomogram.

  6. Primary pulmonary tuberculosis in infancy: A resurgent disease in the urban United States

    International Nuclear Information System (INIS)

    Amodio, J.; Abramson, S.; Berdon, W.

    1986-01-01

    Primary pulmonary tuberculosis in infancy still exists in the urban United States, reflecting new immigrations from less developed areas. The clinical diagnosis may be difficult and routine chest radiographs may be confusing. We found magnification high KV filtered radiography to be very useful in delineating the primary complex and its effect on the tracheobronchial tree. Twelve infants and small children with primary pulmonary tuberculosis were seen in the years 1978-1984. (orig.)

  7. Explicit isospectral flows associated to the AKNS operator on the unit interval. II

    Science.gov (United States)

    Amour, Laurent

    2012-10-01

    Explicit flows associated to any tangent vector fields on any isospectral manifold for the AKNS operator acting in L2 × L2 on the unit interval are written down. The manifolds are of infinite dimension (and infinite codimension). The flows are called isospectral and also are Hamiltonian flows. It is proven that they may be explicitly expressed in terms of regularized determinants of infinite matrix-valued functions with entries depending only on the spectral data at the starting point of the flow. The tangent vector fields are decomposed as ∑ξkTk where ξ ∈ ℓ2 and the Tk ∈ L2 × L2 form a particular basis of the tangent vector spaces of the infinite dimensional manifold. The paper here is a continuation of Amour ["Explicit isospectral flows for the AKNS operator on the unit interval," Inverse Probl. 25, 095008 (2009)], 10.1088/0266-5611/25/9/095008 where, except for a finite number, all the components of the sequence ξ are zero in order to obtain an explicit expression for the isospectral flows. The regularized determinants induce counter-terms allowing for the consideration of finite quantities when the sequences ξ run all over ℓ2.

  8. Explicit isospectral flows for the AKNS operator on the unit interval

    International Nuclear Information System (INIS)

    Amour, L

    2009-01-01

    We consider the AKNS operator on the unit interval. The boundary conditions are self-adjoint separated boundary conditions. For fixed boundary conditions, we make the formulae for flows induced by general tangent vector fields on isospectral sets explicit

  9. Development of high-performance and low-noise axial-flow fan units in their local operating region

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Seung; Ha, Min Ho; Cheong, Cheol Ung [Pusan National University, Busan (Korea, Republic of); Kim, Tae Hoon [LG Electronics Inc., Changwon (Korea, Republic of)

    2015-09-15

    Aerodynamic and aeroacoustic performances of an axial-flow fan unit are improved by modifying its housing structure without changing the fan blade. The target axial-flow fan system is used to lower temperature of a compressor and a condenser in the machine room of a household refrigerator which has relatively high system resistance due to complex layout of structures inside it. First, the performance of the fan system is experimentally characterized by measuring its volume flow rate versus static pressure using a fan performance tester satisfying the AMCA (Air Movement and Control Association) regulation, AMCA 210-07. The detailed structure of flow driven by the fan is numerically investigated using a virtual fan performance tester based on computational fluid dynamics techniques. The prediction result reveals possible loss due to radial and tangential velocity components in the wake flow downstream of the fan. The length of the fan housing is chosen as a design parameter for improving the aerodynamic and aeroacoustic performances of the fan unit by reducing the identified radial and tangential velocity components. Three fan units with different housing lengths longer than the original are analyzed using the virtual fan performance tester. The results confirm the improved aerodynamic performance of the proposed three designs. The flow field driven by the proposed fan unit is closely examined to find the causes for the observed performance improvements, which ensures that the radial and tangential velocity components in the wake flow are reduced. Finally, the improved performance of the proposed fan systems is validated by comparing the P-Q and efficiency curves measured using the fan performance tester. The noise emission from the household refrigerator is also found to be lessened when the new fan units are installed.

  10. Determination of primary flow by correlation of temperatures of the coolant

    International Nuclear Information System (INIS)

    Villanueva, Jose

    2003-01-01

    Correlation techniques are often used to assess primary coolant flow in nuclear reactors. Observable fluctuations of some physical or chemical coolant properties are suitable for this purpose. This work describes a development carried out at the National Atomic Energy Commission of Argentina (CNEA) to apply this technique to correlate temperature fluctuations. A laboratory test was performed. Two thermocouples were installed on a hydraulic loop. A stationary flow of water circulated by the mentioned loop, where a mechanical turbine type flowmeter was installed. Transit times given by the correlation flowmeter, for different flow values measured with the mechanical flowmeter, were registered and a calibration between them was done. A very good linear behavior was obtained in all the measured range. It was necessary to increase the fluctuation level by adding water at different temperatures at the measuring system input. (author)

  11. Numerical groundwater-flow model of the Minnelusa and Madison hydrogeologic units in the Rapid City area, South Dakota

    Science.gov (United States)

    Putnam, Larry D.; Long, Andrew J.

    2009-01-01

    The city of Rapid City and other water users in the Rapid City area obtain water supplies from the Minnelusa and Madison aquifers, which are contained in the Minnelusa and Madison hydrogeologic units. A numerical groundwater-flow model of the Minnelusa and Madison hydrogeologic units in the Rapid City area was developed to synthesize estimates of water-budget components and hydraulic properties, and to provide a tool to analyze the effect of additional stress on water-level altitudes within the aquifers and on discharge to springs. This report, prepared in cooperation with the city of Rapid City, documents a numerical groundwater-flow model of the Minnelusa and Madison hydrogeologic units for the 1,000-square-mile study area that includes Rapid City and the surrounding area. Water-table conditions generally exist in outcrop areas of the Minnelusa and Madison hydrogeologic units, which form generally concentric rings that surround the Precambrian core of the uplifted Black Hills. Confined conditions exist east of the water-table areas in the study area. The Minnelusa hydrogeologic unit is 375 to 800 feet (ft) thick in the study area with the more permeable upper part containing predominantly sandstone and the less permeable lower part containing more shale and limestone than the upper part. Shale units in the lower part generally impede flow between the Minnelusa hydrogeologic unit and the underlying Madison hydrogeologic unit; however, fracturing and weathering may result in hydraulic connections in some areas. The Madison hydrogeologic unit is composed of limestone and dolomite that is about 250 to 610 ft thick in the study area, and the upper part contains substantial secondary permeability from solution openings and fractures. Recharge to the Minnelusa and Madison hydrogeologic units is from streamflow loss where streams cross the outcrop and from infiltration of precipitation on the outcrops (areal recharge). MODFLOW-2000, a finite-difference groundwater-flow

  12. The efficacy of IntraFlow intraosseous injection as a primary anesthesia technique.

    Science.gov (United States)

    Remmers, Todd; Glickman, Gerald; Spears, Robert; He, Jianing

    2008-03-01

    The purpose of this study was to compare the efficacy of intraosseous injection and inferior alveolar (IA) nerve block in anesthetizing mandibular posterior teeth with irreversible pulpitis. Thirty human subjects were randomly assigned to receive either intraosseous injection using the IntraFlow system (Pro-Dex Inc, Santa Ana, CA) or IA block as the primary anesthesia method. Pulpal anesthesia was evaluated via electric pulp testing at 4-minute intervals for 20 minutes. Two consecutive 80/80 readings were considered successful pulpal anesthesia. Anesthesia success or failure was recorded and groups compared. Intraosseous injection provided successful anesthesia in 13 of 15 subjects (87%). The IA block provided successful anesthesia in 9 of 15 subjects (60%). Although this difference was not statistically significant (p = 0.2148), the results of this preliminary study indicate that the IntraFlow system can be used as the primary anesthesia method in teeth with irreversible pulpitis to achieve predictable pulpal anesthesia.

  13. Continuous-flow oxidative cyanation of primary and secondary amines using singlet oxygen.

    Science.gov (United States)

    Ushakov, Dmitry B; Gilmore, Kerry; Kopetzki, Daniel; McQuade, D Tyler; Seeberger, Peter H

    2014-01-07

    Primary and secondary amines can be rapidly and quantitatively oxidized to the corresponding imines by singlet oxygen. This reactive form of oxygen was produced using a variable-temperature continuous-flow LED-photoreactor with a catalytic amount of tetraphenylporphyrin as the sensitizer. α-Aminonitriles were obtained in good to excellent yields when trimethylsilyl cyanide served as an in situ imine trap. At 25°C, primary amines were found to undergo oxidative coupling prior to cyanide addition and yielded secondary α-aminonitriles. Primary α-aminonitriles were synthesized from the corresponding primary amines for the first time, by an oxidative Strecker reaction at -50 °C. This atom-economic and protecting-group-free pathway provides a route to racemic amino acids, which was exemplified by the synthesis of tert-leucine hydrochloride from neopentylamine. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Flow dynamics study of catalyst powder in catalytic cracking unit for troubleshooting

    Directory of Open Access Journals (Sweden)

    Yelgaonkar Vivek

    2017-12-01

    Full Text Available Gamma scanning and radiotracer applications are very effective and inexpensive tools to understand and optimize the process as well as troubleshoot the various types of problems in many chemical, petrochemical industries and refineries. These techniques are non-invasive; hence, the problems can be pinpointed online, which leads to reduce the downtime, schedule the shutdown and maintenance of the plant equipment, rendering huge economic benefits. In a leading refinery of India, the catalytic cracking unit (CCU was malfunctioning. It was suspected by the refinery engineers that the catalyst powder was being carried over to the fractionator, which could have led to erosion of the fractionator column internals resulting in their rupture, and consequentially, to the fire hazard. To understand the flow behaviour of the catalyst powder and to ensure the mechanical integrity, catalyst accumulation and choking, both radiotracer study and gamma scanning of the CCU reactor was carried out. The reactor consists of a riser, three primary cyclones and three secondary cyclones. Gamma scanning of the reactor was carried out with the help of an automatic gamma scanner using 1.8 GBq of Co-60 sealed source. Results showed that the catalyst powder was accumulated in one of the secondary cyclones and uneven density distribution was observed in another secondary cyclone. The radiotracer study was carried out using the irradiated catalyst powder as a radiotracer, which contains 0.9 GBq of Na-24. The radiotracer was injected in the reactor through the specially fabricated injection system. Radiation measurement was done using the thermally insulated and collimated NaI(Tl scintillation detectors located at various strategic locations coupled to a multi-detector data acquisition system. The data were mathematically analysed. It was confirmed that the catalyst powder was accumulated in one of the secondary cyclones with no flow downwards. This resulted in excess powder

  15. [Drug supplies in primary care units at the Ministry of Health in Mexico].

    Science.gov (United States)

    Gómez-Dantés, O; Garrido-Latorre, F; Tirado-Gómez, L L; Ramírez, D; Macías, C

    2001-01-01

    To identify the availability of some essential drugs (ED) at primary health care units of the Mexican Ministry of Health (SSA), using data from a research work conducted in 1996 and 1997. A random sample of the 18 sanitary jurisdictions of states participating in the Extension of Coverage Program (ECP) was drawn. All primary care units from selected jurisdictions were evaluated through an inspection visit, using a checklist that included 36 ED. In phase I of the analysis, the absolute number and proportion of units without a single item of any of the 36 drugs were calculated. In the units with available drugs, the median of the distribution was also calculated. In phase II, the medians according to the type of health unit and state was obtained. The statistic utilized for the comparison of the medians was the Scheffé test with one way variance analysis. In addition, the drugs were classified according to their therapeutic indication and the medians and proportion of available drugs were calculated. The differences in proportion were evaluated with the statistic chi 2. During the visits, on average, 18 of the 36 drugs included in the list of the study were found in the health units. The availability of antibiotics, antituberculosis drugs, and antimalarial drugs was particularly poor. In contrast, oral rehydration salts, family planning methods and vaccines were usually available. In general, the PAC3 states presented the best availability figures. The Ministry of Health of México will have to develop an enormous effort to overcome the obstacles related to the supply of essential drugs in primary health care units. Otherwise, all other efforts directed to meet the needs of the non-insured population will end up being useless, and enormous amounts of the already scarce resources of the health sector will be wasted since drugs are a vital component of the long chain of health care.

  16. Sensitivity of Regulated Flow Regimes to Climate Change in the Western United States

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tian [Pacific Northwest National Laboratory, Richland, Washington; Voisin, Nathalie [Pacific Northwest National Laboratory, Richland, Washington; Leng, Guoyong [Pacific Northwest National Laboratory, Richland, Washington; Huang, Maoyi [Pacific Northwest National Laboratory, Richland, Washington; Kraucunas, Ian [Pacific Northwest National Laboratory, Richland, Washington

    2018-03-01

    Water management activities or flow regulations modify water fluxes at the land surface and affect water resources in space and time. We hypothesize that flow regulations change the sensitivity of river flow to climate change with respect to unmanaged water resources. Quantifying these changes in sensitivity could help elucidate the impacts of water management at different spatiotemporal scales and inform climate adaptation decisions. In this study, we compared the emergence of significant changes in natural and regulated river flow regimes across the Western United States from simulations driven by multiple climate models and scenarios. We find that significant climate change-induced alterations in natural flow do not cascade linearly through water management activities. At the annual time scale, 50% of the Hydrologic Unit Code 4 (HUC4) sub-basins over the Western U.S. regions tend to have regulated flow regime more sensitive to the climate change than natural flow regime. Seasonality analyses show that the sensitivity varies remarkably across the seasons. We also find that the sensitivity is related to the level of water management. For 35% of the HUC4 sub-basins with the highest level of water management, the summer and winter flows tend to show a heightened sensitivity to climate change due to the complexity of joint reservoir operations. We further demonstrate that the impacts of considering water management in models are comparable to those that arises from uncertainties across climate models and emission scenarios. This prompts further climate adaptation studies research about nonlinearity effects of climate change through water management activities.

  17. Condition monitoring of primary coolant pump-motor units of Indian PHWR

    International Nuclear Information System (INIS)

    Rshikesan, P.B.; Sharma, S.S.; Mhetre, S.G.

    1994-01-01

    As the primary coolant pump motor units are located in shut down accessible area, their start up, satisfactory operation and shut down are monitored from control room. As unavailability of one pump in standardised 220 MWe station reduces the station power to about 110 MWe, satisfactory operation of the pump is also important from economic considerations. All the critical parameters of pump shaft, mechanical seal, bearing system, motor winding and shaft displacement (vibrations) are monitored/recorded to ensure satisfactory operation of critical, capital intensive pump-motor units. (author). 2 tabs., 1 fig

  18. Influence of chemistry on steam generator primary-to-secondary stabilized low leak flow rate

    International Nuclear Information System (INIS)

    Hervouet, C.; Pages, D.; Fauchon, C.; Bretelle, J.L.; Bus, F.

    2002-01-01

    The comparison of the leak flow rate behavior between the previous and the new boron/lithium coordination, the second one corresponding to an higher pH during the cycle than the first one, leads to the following conclusions, confirmed by the experimental and theoretical studies: Low leak flow rate is extremely sensitive to pH in the zone of pH of primary water because the behavior of metallic oxide is changing drastically in that range of pH (from precipitation to dissolution); Leak flow rate is often maintained lower with low pH. Let's recall however that pH can not reach a too low value which could enhance corrosion product deposition, increase dose rates along the primary circuit, and lead to reactor outages due to problems on fuel assemblies. The understanding of the governing phenomena led to adapt in 2000 the reactor cooling system chemical conditioning for the French Pressurized Water reactors facing problems with the management of the stabilized leak flow rate fluctuations, once no degradation of tube bundle integrity is proved. Each part of the cycle and operating conditions lead to an advised operating action. In general, the new recommendations for the reactors facing problems with the management of low leak flow rate are based on the principle of helping the precipitation of metallic oxide within the crack and preventing their dissolution. (authors)

  19. Method for heating of the primary circuit of WWER electric power units at cold start-up

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Dimitrov, B.D.; Korkinova, M.I.

    1982-01-01

    The method increases the heating rate and shorten the start-up time of the electric power units. It comprises a primary stopping of the reactor core heating and provides a forced circulation of the heat-carrier through the circulation cycles of the primary circuit. The thermal energy is supplied in one or several steam generators in the secondary circuit of an NPP operating unit. 1 cl., 3 figs

  20. Analysis of physical flows in primary commodity trade. A case study in China

    International Nuclear Information System (INIS)

    Ma, Tao; Li, Bo; Fang, Changming; Zhao, Bin; Luo, Yiqi; Chen, Jiakuan

    2006-01-01

    How globalization and international trade affect sustainable development and environment has attracted worldwide attention. Associated with the import and export of primary commodities, ecologically important materials have been exchanged among regions and countries. China, having the largest population in the world and the highest economic growth rate in last decades, may have an important influence on global sustainable development through the trade of primary commodities. Using the data from Almanac of China's Foreign Economic Relations and Trade, we analyzed material flows in the trade of primary commodity in China from 1950 to 2001. Our analysis shows that: (1) China has turned from a net exporter of primary commodities to a net importer; (2) minerals and fuels have been the major imports of primary commodities since 1992, just as well as foods and minerals did in 1980s; (3) most of the net imported primary commodities come from Oceania, Africa and Latin America. (author)

  1. Evaluating Maternity Units: a prospective cohort study of freestanding midwife-led primary maternity units in New Zealand—clinical outcomes

    Science.gov (United States)

    Grigg, Celia P; Tracy, Sally K; Tracy, Mark; Daellenbach, Rea; Kensington, Mary; Monk, Amy; Schmied, Virginia

    2017-01-01

    Objective To compare maternal and neonatal birth outcomes and morbidities associated with the intention to give birth in a freestanding primary level midwife-led maternity unit (PMU) or tertiary level obstetric-led maternity hospital (TMH) in Canterbury, Aotearoa/New Zealand. Design Prospective cohort study. Participants 407 women who intended to give birth in a PMU and 285 women who intended to give birth at the TMH in 2010–2011. All of the women planning a TMH birth were ‘low risk’, and 29 of the PMU cohort had identified risk factors. Primary outcomes Mode of birth, Apgar score of less than 7 at 5 min and neonatal unit admission. Secondary outcomes: labour onset, analgesia, blood loss, third stage of labour management, perineal trauma, non-pharmacological pain relief, neonatal resuscitation, breastfeeding, gestational age at birth, birth weight, severe morbidity and mortality. Results Women who planned a PMU birth were significantly more likely to have a spontaneous vaginal birth (77.9%vs62.3%, adjusted OR (AOR) 1.61, 95% CI 1.08 to 2.39), and significantly less likely to have an instrumental assisted vaginal birth (10.3%vs20.4%, AOR 0.59, 95% CI 0.37 to 0.93). The emergency and elective caesarean section rates were not significantly different (emergency: PMU 11.6% vs TMH 17.5%, AOR 0.88, 95% CI 0.55 to 1.40; elective: PMU 0.7% vs TMH 2.1%, AOR 0.34, 95% CI 0.08 to 1.41). There were no significant differences between the cohorts in rates of 5 min Apgar score of <7 (2.0%vs2.1%, AOR 0.82, 95% CI 0.27 to 2.52) and neonatal unit admission (5.9%vs4.9%, AOR 1.44, 95% CI 0.70 to 2.96). Planning to give birth in a primary unit was associated with similar or reduced odds of intrapartum interventions and similar odds of all measured neonatal well-being indicators. Conclusions The results of this study support freestanding midwife-led primary-level maternity units as physically safe places for well women to plan to give birth, with these women having

  2. Estimating the unit costs of public hospitals and primary healthcare centers.

    Science.gov (United States)

    Younis, Mustafa Z; Jaber, Samer; Mawson, Anthony R; Hartmann, Michael

    2013-01-01

    Many factors have affected the rise of health expenditures, such as high-cost medical technologies, changes in disease patterns and increasing demand for health services. All countries allocate a significant portion of resources to the health sector. In 2008, the gross domestic product of Palestine was estimated to be at $6.108bn (current price) or about $1697 per capita. Health expenditures are estimated at 15.6% of the gross domestic product, almost as much as those of Germany, Japan and other developed countries. The numbers of hospitals, hospital beds and primary healthcare centers in the country have all increased. The Ministry of Health (MOH) currently operates 27 of 76 hospitals, with a total of 3074 beds, which represent 61% of total beds of all hospitals in the Palestinian Authorities area. Also, the MOH is operating 453 of 706 Primary Health Care facilities. By 2007, about 40 000 people were employed in different sectors of the health system, with 33% employed by the MOH. This purpose of this study was to develop a financing strategy to help cover some or all of the costs involved in operating such institutions and to estimate the unit cost of primary and secondary programs and departments. A retrospective study was carried out on data from government hospitals and primary healthcare centers to identify and analyze the costs and output (patient-related services) and to estimate the unit cost of health services provided by hospitals and PHCs during the year 2008. All operating costs are assigned and allocated to the departments at MOH hospitals and primary health care centers (PPHCs) and are identified as overhead departments, intermediate-service and final-service departments. Intermediate-service departments provide procedures and services to patients in the final-service departments. The costs of the overhead departments are distributed to the intermediate-service and final-service departments through a step-down method, according to allocation

  3. Engine Tune-Up Service. Unit 3: Primary Circuit. Review Exercise Book. Automotive Mechanics Curriculum.

    Science.gov (United States)

    Bacon, E. Miles

    This book of pretests and review exercises is designed to accompany the Engine Tune-Up Service Student Guide for Unit 3, Primary Circuit, available separately as CE 031 211. Focus of the exercises and pretests is testing the primary ignition circuit. Pretests and performance checklists are provided for each of the eight performance objectives…

  4. Using Sankey diagrams to map energy flow from primary fuel to end use

    International Nuclear Information System (INIS)

    Subramanyam, Veena; Paramshivan, Deepak; Kumar, Amit; Mondal, Md. Alam Hossain

    2015-01-01

    Highlights: • Energy flows from both supply and demand sides shown through Sankey diagrams. • Energy flows from reserves to energy end uses for primary and secondary fuels shown. • Five main energy demand sectors in Alberta are analyzed. • In residential/commercial sectors, highest energy consumption is in space heating. • In the industrial sector, highest energy use is in the mining subsector. - Abstract: The energy sector is the largest contributor to gross domestic product (GDP), income, employment, and government revenue in both developing and developed nations. But the energy sector has a significant environmental footprint due to greenhouse gas (GHG) emissions. Efficient production, conversion, and use of energy resources are key factors for reducing the environmental footprint. Hence it is necessary to understand energy flows from both the supply and the demand sides. Most energy analyses focus on improving energy efficiency broadly without considering the aggregate energy flow. We developed Sankey diagrams that map energy flow for both the demand and supply sides for the province of Alberta, Canada. The diagrams will help policy/decision makers, researchers, and others to understand energy flow from reserves through to final energy end uses for primary and secondary fuels in the five main energy demand sectors in Alberta: residential, commercial, industrial, agricultural, and transportation. The Sankey diagrams created for this study show total energy consumption, useful energy, and energy intensities of various end-use devices. The Long-range Energy Alternatives Planning System (LEAP) model is used in this study. The model showed that Alberta’s total input energy in the five demand sectors was 189 PJ, 186 PJ, 828.5PJ, 398 PJ, and 50.83 PJ, respectively. On the supply side, the total energy input and output were found to be 644.84 PJ and 239 PJ, respectively. These results, along with the associated energy flows were depicted pictorially using

  5. Determination of the catalyst circulation rate in a FCC cold flow pilot unit using nuclear techniques

    International Nuclear Information System (INIS)

    Santos, Valdemir A. dos; Lima, Emerson A.O.

    2013-01-01

    Nuclear techniques of gamma transmission and radioactive tracer were used to estimate the catalyst circulation rate in a cold flow pilot plant unit of Fluid Catalytic Cracking (FCC). Catalyst circulation rate in a FCC unit, allow to determine operating conditions of the exchange catalyst and inlet data for fluid dynamic simulation computational program. The pilot unit was fabricated obeying geometrical parameters provided by the Petrobras Research Center (CENPES), based on hot pilot units to existing in that center. The cold flow pilot unit has a transfer line, two separation vessels flash type, a return column, a riser and a regenerator. The vertical sections as riser, return column, regenerator column and transfer line are made of transparent material (glass). The two separation vessels have bases with tapered cylindrical shapes and are made of steel plates. The riser is divided into four sections of different diameters (0.005 m, 0.010 m, 0.018 m and 0.025 m) and rising upwards, to simulate the increasing flow rate caused by the increase of volume with the increase of the number of moles due to molecules breakage. The radioactive tracer used was the catalyst itself (intrinsic tracer) irradiated by neutron activation, yielding the radioisotope 59 Fe. The velocity measurements were also obtained with aid of an electronic clock triggered by certain radiation levels across the two detectors. Besides estimates for the catalyst circulation rate was possible to identify the type of flow relative to the catalyst in return column. (author)

  6. Primary water chemistry control at units of Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Schunk, J.; Patek, G.; Pinter, T.; Tilky, P.; Doma, A.; Osz, J.

    2010-01-01

    The primary water chemistry of the four identical units of Paks Nuclear Power Plant has been developed based on Western-type PWR units, taking into consideration some Soviet-Russian modifications. The political changes in 90s have also influenced the water chemistry specifications and directions. At PWR units the transition operational modes have been developed while in case of VVER units - in lack of central uniform regulation - this question has become the competence and responsibility of each individual plant. This problem has resulted in separate water chemistry developments with a considerable time delay. The needs for life-time extensions all over the World have made the development of start-up and shut-down chemistry procedures extremely important, since they considerably influence the long term and safe operation of plants. The uniformly structured limit value system, the principles applied for the system development, and the logic schemes for actions to be taken are discussed in the paper, both for normal operation and transition modes. (author)

  7. Primary Water Chemistry Control at Units of Paks Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Schunk, J.; Pinter, G. Patek T.; Tilky, P.; Doma, A. [Paks Nuclear Power Plant Co. Ltd., Paks (Hungary); Osz, J. [Budapest University of Technology and Economics, Budapest (Hungary)

    2013-03-15

    The primary water chemistry of the four identical units of Paks Nuclear Power Plant has been developed based on Western type PWR units, taking into consideration some Russian modifications. The political changes in the 1990s have also influenced the water chemistry specifications and directions. At PWR units the transition operational modes have been developed while in case of WWER units - in lack of central uniform regulation - this question has become the competence and responsibility of each individual plant. This problem has resulted in separate water chemistry developments with a considerable time delay. The need for lifetime extensions worldwide has made the development of startup and shutdown chemistry procedures extremely important, since they considerably influence the long term and safe operation of plants. The uniformly structured limit value system, the principles applied for the system development, and the logic schemes for actions to be taken are discussed in the paper, both for normal operation and transition modes. (author)

  8. Measurement system of bubbly flow using Ultrasonic Velocity Profile Monitor and Video Data Processing Unit. 3. Comparison of flow characteristics between bubbly cocurrent and countercurrent flows

    International Nuclear Information System (INIS)

    Zhou, Shirong; Suzuki, Yumiko; Aritomi, Masanori; Matsuzaki, Mitsuo; Takeda, Yasushi; Mori, Michitsugu

    1998-01-01

    The authors have developed a new measurement system which consisted of an Ultrasonic Velocity Profile Monitor (UVP) and a Video Data Processing Unit (VDP) in order to clarify the two-dimensional flow characteristics in bubbly flows and to offer a data base to validate numerical codes for two-dimensional two-phase flow. In the present paper, the proposed measurement system is applied to fully developed bubbly cocurrent flows in a vertical rectangular channel. At first, both bubble and water velocity profiles and void fraction profiles in the channel were investigated statistically. In addition, the two-phase multiplier profile of turbulence intensity, which was defined as a ratio of the standard deviation of velocity fluctuation in a bubbly flow to that in a water single phase flow, were examined. Next, these flow characteristics were compared with those in bubbly countercurrent flows reported in our previous paper. Finally, concerning the drift flux model, the distribution parameter and drift velocity were obtained directly from both bubble and water velocity profiles and void fraction profiles, and their results were compared with those in bubbly countercurrent flows. (author)

  9. Psychiatric disorders in children attending a Nigerian primary care unit: functional impairment and risk factors

    Directory of Open Access Journals (Sweden)

    Tunde-Ayinmode Mosunmola

    2012-07-01

    Full Text Available Abstract Background There is dearth of data on the level of functional impairment and risk factors for psychiatric morbidity in children attending primary care services in developing countries like Nigeria. The risk factors for psychiatric morbidity and functional impairment in children attending the primary care unit of a teaching hospital in Ilorin, Nigeria was therefore investigated to obtain data that could be used in improving service provision by primary care physicians. Methods A cross-sectional two-stage design was employed for the study. The first stage involved administration of the Child Behavior Questionnaire (CBQ to 350 children while the children’s version of the schedule for affective disorders and schizophrenia was used for the second stage involving 157 children, all high scorers on CBQ (score of ≥ 7 and 30% of low scorers (score  In addition, the Children Global Assessment Scale was used to assess the functional status of the children (score of ≤ 70 indicates functional impairment while the mothers’ mental health status was assessed with the 12-item version of the General Health Questionnaire, a score of 3 or more on this instrument indicate presence of mental morbidity. Results It was observed that 11.4% of the children had diagnosable psychiatric disorders and 7.1% were functionally impaired; and those with psychiatric disorders were more functionally impaired than those without. Thus, significant negative correlation was noted between CBQ scores and CGAS (r = 0.53; p  Conclusions Child psychiatric disorders are prevalent in the primary care unit studied. Many of the risk factors identified in the study population are modifiable. Collaborative efforts between psychiatrists and primary care physicians could therefore help to reduce level of risk and functional impairment and psychiatric morbidity among children attending the primary care unit studied. It could also help improve referral rates of

  10. Flowing-water optical power meter for primary-standard, multi-kilowatt laser power measurements

    Science.gov (United States)

    Williams, P. A.; Hadler, J. A.; Cromer, C.; West, J.; Li, X.; Lehman, J. H.

    2018-06-01

    A primary-standard flowing-water optical power meter for measuring multi-kilowatt laser emission has been built and operated. The design and operational details of this primary standard are described, and a full uncertainty analysis is provided covering the measurement range from 1–10 kW with an expanded uncertainty of 1.2%. Validating measurements at 5 kW and 10 kW show agreement with other measurement techniques to within the measurement uncertainty. This work of the U.S. Government is not subject to U.S. copyright.

  11. Primary shutdown system monitoring unit for nuclear power plants

    International Nuclear Information System (INIS)

    Khan, Tahir Kamal; Balasubramanian, R.; Agilandaeswari, K.

    2013-01-01

    Shut off rods made up of neutron absorbing material are used as Primary Shutdown System. To reduce the power of the reactor under certain abnormal operating conditions, these rods must go down into the core within a specified time. Any malfunctioning in the movement of rods cannot be tolerated and Secondary Shutdown System (SSS) must be actuated within stipulated time to reduce the reactor power. A special safety critical, hardwired electronics unit has been designed to detect failure of PSS Shut off rods movements and generate trip signals for initiating SSS. (author)

  12. Pena Blanca uranium deposits and ash-flow tuffs relationship

    International Nuclear Information System (INIS)

    Magonthier, M.

    1987-01-01

    The Pena Blanca uranium deposits (Chihuahua, Mexico) are associated with a Tertiary sequence of ash-flow tuffs. Stratigraphic control is dominant and uranium mineralization occurs in stratiform and fracture-controlled deposits within 44 My-old units: Nopal Rhyolite and Escuadra Rhyolite. These units consist of highly vapor-phase crystallized ash-flow tuffs. They contain sanidine, quartz and granophyric phenocrysts, and minor ferromagnesian silicates. Nopal and Escuadra units are high-silica alkali-rich rhyolites that have a primary potassic character. The trace-element chemistry shows high concentrations in U-Th-Rb-Cs and low contents in Ba-Sr-Eu. These chemical properties imply a genetic relationship between deposits and host-units. The petrochemical study show that the Nopal Rhyolite and Escuadra Rhyolite are the source of U and of hydrothermal solutions [fr

  13. The impact of hydraulic flow unit & reservoir quality index on pressure profile and productivity index in multi-segments reservoirs

    Directory of Open Access Journals (Sweden)

    Salam Al-Rbeawi

    2017-12-01

    Full Text Available The objective of this paper is studying the impact of the hydraulic flow unit and reservoir quality index (RQI on pressure profile and productivity index of horizontal wells acting in finite reservoirs. Several mathematical models have been developed to investigate this impact. These models have been built based on the pressure distribution in porous media, depleted by a horizontal well, consist of multi hydraulic flow units and different reservoir quality index. The porous media are assumed to be finite rectangular reservoirs having different configurations and the wellbores may have different lengths. Several analytical models describing flow regimes have been derived wherein hydraulic flow units and reservoir quality index have been included in addition to rock and fluid properties. The impact of these two parameters on reservoir performance has also been studied using steady state productivity index.It has been found that both pressure responses and flow regimes are highly affected by the existence of multiple hydraulic flow units in the porous media and the change in reservoir quality index for these units. Positive change in the RQI could lead to positive change in both pressure drop required for reservoir fluids to move towards the wellbore and hence the productivity index.

  14. The United States Chiropractic Workforce: An alternative or complement to primary care?

    Directory of Open Access Journals (Sweden)

    Davis Matthew A

    2012-11-01

    Full Text Available Abstract Background In the United States (US a shortage of primary care physicians has become evident. Other health care providers such as chiropractors might help address some of the nation’s primary care needs simply by being located in areas of lesser primary care resources. Therefore, the purpose of this study was to examine the distribution of the chiropractic workforce across the country and compare it to that of primary care physicians. Methods We used nationally representative data to estimate the per 100,000 capita supply of chiropractors and primary care physicians according to the 306 predefined Hospital Referral Regions. Multiple variable Poisson regression was used to examine the influence of population characteristics on the supply of both practitioner-types. Results According to these data, there are 74,623 US chiropractors and the per capita supply of chiropractors varies more than 10-fold across the nation. Chiropractors practice in areas with greater supply of primary care physicians (Pearson’s correlation 0.17, p-value  Conclusion These findings suggest that chiropractors practice in areas of greater primary care physician supply. Therefore chiropractors may be functioning in more complementary roles to primary care as opposed to an alternative point of access.

  15. Test plan for evaluation of primary exhaust ventilation flow meters for double shell hydrogen watch list tanks

    International Nuclear Information System (INIS)

    Willingham, W.E.

    1996-01-01

    This document is a plan for testing four different flow meters for use in the primary exhaust ventilation ducts of Double Shell Tanks on the hydrogen watch list that do not already have this capability. This currently includes tanks 241-AW-101, 241-AN-103, 241-AN-104, 241-AN-105, and 241-SY-103. The anticipated airflow velocity in these tanks range from 0.25 m/s(50 ft/min) to 1.78 m/s (350 ft/min). Past experiences at Hanford are forcing the evaluation and selection of instruments to be used at the low flow and relatively high humidity conditions found in these tanks. Based on the results of this test, a flow meter shall be chosen for installation in the primary exhaust ventilation ducts of the above mentioned waste tanks

  16. Operational monitoring of temperature and state of stress of primary collectors, their stud bolts and cover and temperatures of steam generator's pressure vessel at the nuclear power unit WWER 440

    International Nuclear Information System (INIS)

    Matal, O.; Simo, T.; Holy, F.; Vejvoda, S.

    1992-01-01

    Both primary collectors of the WWER 440 steam generator (STGE) are vertically positioned inside the STGE pressure vessel and connected in their lower part to the primary piping and closed at their upper part by primary covers. The primary cover is pushed against the primary collector flange by 20 stud bolts. Two nickel packing rings are fitted between the primary cover and collector. A leakage in the collector-cover junction could cause flow of the radioactive water into the clean secondary water. If the junction is made in accordance with the Soviet standard design the computed stresses exceed the allowable value in the stud bolts by a factor of 1.5. Therefore an improved design of the primary collector - primary cover flange joint was designed and tested on one STGE at a WWER 440 nuclear power unit in Czechoslovakia. The paper describes the system of joint properties measurement, gives some substantial characteristics of the new stud bolts and primary cover design and comments on significant measured results of state of stress and temperatures in comparison with the operational regime of the STGE. (orig.)

  17. Prevalence and factors associated with breast milk donation in banks that receive human milk in primary health care units.

    Science.gov (United States)

    Meneses, Tatiana Mota Xavier de; Oliveira, Maria Inês Couto de; Boccolini, Cristiano Siqueira

    To estimate the prevalence and to analyze factors associated with breast milk donation at primary health care units in order to increase the human milk bank reserves. Cross-sectional study carried out in 2013 in Rio de Janeiro, Brazil. A representative sample of 695 mothers of children younger than 1 year attended to at the nine primary health care units with human milk donation services were interviewed. A hierarchical approach was used to obtain adjusted prevalence ratios (APR) by Poisson regression with robust variance. The final model included the variables associated with breast milk donation (p≤0.05). 7.3% of the mothers had donated breast milk. Having been encouraged to donate breast milk by healthcare professionals, relatives, or friends (APR=7.06), receiving information on breast milk expression by the primary health care unit (APR=3.65), and receiving help from the unit professionals to breastfeed (APR=2.24) were associated with a higher prevalence of donation. Admission of the newborn to the neonatal unit was associated with a lower prevalence of donation (APR=0.09). Encouragement to breast milk donation, and information and help provided by primary health care unit professionals to breastfeeding were shown to be important for the practice of human milk donation. Copyright © 2017. Published by Elsevier Editora Ltda.

  18. Relationship between early administration of abciximab and TIMI flow in STEMI patients undergoing primary angioplasty: findings from a large regional STEMI network.

    Science.gov (United States)

    Izzo, Antonio; Rosiello, Renato; Lucchini, Giuseppe; Tomasi, Luca; Mantovani, Paola; Lettieri, Corrado; Baccaglioni, Nicola; Romano, Michele; Buffoli, Francesca; Izzo, Beatrice; Zanini, Roberto

    2017-06-01

    The aim of this study is to assess whether in S-T Elevation Myocardial Infarction (STEMI) a relationship between early administration of abciximab and Thrombolysis In Myocardial Infarction (TIMI) flow before and after primary percutaneous coronary intervention (PCI) in 960 consecutive patients exists. From 1 February 2001 onward, in the Province of Mantua it has been operating a 'Cardiology Network for the Acute Infarction Care' having its Hub in the Central Coronary ICU/Cath Lab of Mantua Hospital and being its Spokes centers represented by the emergency rooms and Central Coronary ICUs of the four territorial hospitals. T1 (time from symptoms onset to first medical contact) and T2 (time from first medical contact to angioplasty) are shorter for patients rescued by first aid units rather than for those presented in emergency rooms as well as Ta (time from symptoms onset to abciximab administration). Furthermore, the patients that received abciximab before hospital arrival had less frequently a coronary occlusion [odds ratio = 0.74, 95% confidence interval (0.57-0.96), P = 0.013]. The patients with T1 less than 4 h are 753/960 (78.4%). For this type of patients, there was a significant Ta difference between the pre-PCI TIMI-flow classes (F = 4.467, df = 3, P = 0.04). Planned contrasts revealed that mean time of TIMI flow 0 (M = 104.2) is statistically different from mean time of TIMI flow 3 (M = 85.7), P = 0.013. Our results suggest that the use of abciximab, free from pharmacokinetic limits of oral P2Y12 inhibitors, should be considered in STEMI patients with early presentation before primary PCI.

  19. Lava flow field emplacement studies of Manua Ulu (Kilauea Volcano, Hawai'i, United States) and Venus, using field and remote sensing analyses

    Science.gov (United States)

    Byrnes, Jeffrey Myer

    2002-04-01

    This work examines lava emplacement processes by characterizing surface units using field and remote sensing analyses in order to understand the development of lava flow fields. Specific study areas are the 1969--1974 Mauna Ulu compound flow field, (Kilauea Volcano, Hawai'i, USA), and five lava flow fields on Venus: Turgmam Fluctus, Zipaltonal Fluctus, the Tuli Mons/Uilata Fluctus flow complex, the Var Mons flow field, and Mylitta Fluctus. Lava surface units have been examined in the field and with visible-, thermal-, and radar-wavelength remote sensing datasets for Mauna Ulu, and with radar data for the Venusian study areas. For the Mauna Ulu flow field, visible characteristics are related to color, glass abundance, and dm- to m-scale surface irregularities, which reflect the lava flow regime, cooling, and modification due to processes such as coalescence and inflation. Thermal characteristics are primarily affected by the abundance of glass and small-scale roughness elements (such as vesicles), and reflect the history of cooling, vesiculation and degassing, and crystallization of the lava. Radar characteristics are primarily affected by unit topography and fracturing, which are related to flow inflation, remobilization, and collapse, and reflect the local supply of lava during and after unit emplacement. Mauna Ulu surface units are correlated with pre-eruption topography, lack a simple relationship to the main feeder lava tubes, and are distributed with respect to their position within compound flow lobes and with distance from the vent. The Venusian lava flow fields appear to have developed through emplacement of numerous, thin, simple and compound flows, presumably over extended periods of time, and show a wider range of radar roughness than is observed at Mauna Ulu. A potential correlation is suggested between flow rheology and surface roughness. Distributary flow morphologies may result from tube-fed flows, and flow inflation is consistent with observed

  20. Measurement system of bubbly flow using ultrasonic velocity profile monitor and video data processing unit

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Zhou, Shirong; Nakajima, Makoto; Takeda, Yasushi; Mori, Michitsugu; Yoshioka, Yuzuru.

    1996-01-01

    The authors have been developing a measurement system for bubbly flow in order to clarify its multi-dimensional flow characteristics and to offer a data base to validate numerical codes for multi-dimensional two-phase flow. In this paper, the measurement system combining an ultrasonic velocity profile monitor with a video data processing unit is proposed, which can measure simultaneously velocity profiles in both gas and liquid phases, a void fraction profile for bubbly flow in a channel, and an average bubble diameter and void fraction. Furthermore, the proposed measurement system is applied to measure flow characteristics of a bubbly countercurrent flow in a vertical rectangular channel to verify its capability. (author)

  1. Unit 1 and Unit 2 Nuclear Power Plant Mochovce construction finishing from primary contractor of technological part. Skoda Praha a. s. point of view

    International Nuclear Information System (INIS)

    Horky, F.

    2000-01-01

    In this paper the history of delivery of technological part for NPP V-1 Mochovce as well as of reconstruction and safety improvements by the Skoda Praha a.s. is presented. Primary contractor of technological part Skoda Praha together with its final suppliers proved ability to realize under hard conditions such a complicated work what was indisputedly Units 1 and 2 finishing. Company proved capability to conform itself flexibly in the course of work to requirements of customer for realization of safety measures which means that Units 1 and 2 fully satisfy international standards. By fulfilment of primary contractor of technology obligations and above all by takeover of complex responsibility for both Units putting in operation including responsibility for 'past' Skoda Praha put away one of basic problems which occurred in decision making to whom will be assigned construction finishing contract. These facts fully qualify Skoda Praha to be selected for possible Units 3 and 4 construction finishing as one of chief construction finishing participant

  2. Pulverulent deposits on fuel assemblies in primary circuit on 2 units at EDF (France)

    International Nuclear Information System (INIS)

    Zatla, A.; Piana, O.

    2015-01-01

    In march 2013, during the moving of some fuel assemblies in the fuel deactivation pool of two units nuclear power plants (Blayais 4 and Chinon B2 units), some fine and powdery deposits in suspension have been observed. In the two cases, the fuel has stayed in the deactivation pool during a long time (12 and 3 months), the units have started for the first time to inject Zinc in the primary circuit in the beginning of the precedent fuel cycle, and the units have operated an extended fuel cycle. EDF has performed analysis to evaluate the harmfulness of the particles and to investigate the mechanisms involved in this phenomenon. 3 conclusions can be drawn. First, the deposits are made up of usual corrosion products issued from the primary circuit components. Secondly, the chemical composition and the powdery characteristics of the deposits exclude nuclear safety risks. Thirdly, the atypical behaviour of the deposits could probably be linked with a modification of their structure due to a zinc effect. Because of the lack of new understanding elements, the extension of zinc injection to other NPP units has been broken off currently in France. EDF is studying the international experience feedback to identify the operating parameters of the nuclear power plant which might influent the phenomenon, and to evaluate if the deposits could enhance fuel cladding corrosion

  3. PFC Performance Improvement of Ultra-supercritical Secondary Reheat Unit

    Directory of Open Access Journals (Sweden)

    Li Jun

    2018-01-01

    Full Text Available Ultra-supercritical secondary reheat unit has been widely used in the world because of its advantages of large capacity, low consumption and high efficiency etc., but rapid load change ability of the turbines to be weakened which caused by its system organization, cannot meet the requirements of power grid frequency modulation. Based on the analysis of the control characteristics of ultra-supercritical once-through reheat unit, the primary frequency control based on feed-water flow overshoot compensation is proposed. The main steam pressure generated by the feed-water is changed to improve the primary frequency control capability. The relevant control strategy has been applied to the 1000MW secondary reheating unit. The results show that the technology is feasible and has high economical efficiency.

  4. Prevalence and factors associated with breast milk donation in banks that receive human milk in primary health care units,

    Directory of Open Access Journals (Sweden)

    Tatiana Mota Xavier de Meneses

    Full Text Available Abstract Objective: To estimate the prevalence and to analyze factors associated with breast milk donation at primary health care units in order to increase the human milk bank reserves. Methods: Cross-sectional study carried out in 2013 in Rio de Janeiro, Brazil. A representative sample of 695 mothers of children younger than 1 year attended to at the nine primary health care units with human milk donation services were interviewed. A hierarchical approach was used to obtain adjusted prevalence ratios (APR by Poisson regression with robust variance. The final model included the variables associated with breast milk donation (p ≤ 0.05. Results: 7.3% of the mothers had donated breast milk. Having been encouraged to donate breast milk by healthcare professionals, relatives, or friends (APR = 7.06, receiving information on breast milk expression by the primary health care unit (APR = 3.65, and receiving help from the unit professionals to breastfeed (APR = 2.24 were associated with a higher prevalence of donation. Admission of the newborn to the neonatal unit was associated with a lower prevalence of donation (APR = 0.09. Conclusions: Encouragement to breast milk donation, and information and help provided by primary health care unit professionals to breastfeeding were shown to be important for the practice of human milk donation.

  5. Development of Portable Flow-Through Electrochemical Sanitizing Unit to Generate Near Neutral Electrolyzed Water.

    Science.gov (United States)

    Zhang, Jufang; Yang, Hongshun; Chan, Joel Zhi Yang

    2018-03-01

    We developed a portable flow-through, electrochemical sanitizing unit to produce near neutral pH electrolyzed water (producing NEW). Two methods of redirecting cathode yields back to the anode chamber and redirecting anode yields the cathode chamber were used. The NEW yields were evaluated, including: free available chlorine (FAC), oxidation-reduction potential (ORP), and pH. The performances of 2 electrodes (RuO 2 -IrO 2 /TiO 2 and IrO 2 -Ta 2 O 5 /TiO 2 ) were investigated. The unit produced NEW at pH 6.46 to 7.17, an ORP of 805.5 to 895.8 mV, and FAC of 3.7 to 82.0 mg/L. The NEW produced by redirecting cathode yields had stronger bactericidal effects than the NEW produced by redirecting anode yields or NEW produced by mixing the commercial unit's anode and cathode product (P portable flow-through, NEW-producing unit has great potential in a wide range of applications, such as organic farm, households, and small food industries. The examined sanitizing treatments showed effective control of Escherichia coli O157:H7 and Listeria monocytogenes. © 2018 Institute of Food Technologists®.

  6. A decomposition method for network-constrained unit commitment with AC power flow constraints

    International Nuclear Information System (INIS)

    Bai, Yang; Zhong, Haiwang; Xia, Qing; Kang, Chongqing; Xie, Le

    2015-01-01

    To meet the increasingly high requirement of smart grid operations, considering AC power flow constraints in the NCUC (network-constrained unit commitment) is of great significance in terms of both security and economy. This paper proposes a decomposition method to solve NCUC with AC power flow constraints. With conic approximations of the AC power flow equations, the master problem is formulated as a MISOCP (mixed integer second-order cone programming) model. The key advantage of this model is that the active power and reactive power are co-optimised, and the transmission losses are considered. With the AC optimal power flow model, the AC feasibility of the UC result of the master problem is checked in subproblems. If infeasibility is detected, feedback constraints are generated based on the sensitivity of bus voltages to a change in the unit reactive power generation. They are then introduced into the master problem in the next iteration until all AC violations are eliminated. A 6-bus system, a modified IEEE 30-bus system and the IEEE 118-bus system are used to validate the performance of the proposed method, which provides a satisfactory solution with approximately 44-fold greater computational efficiency. - Highlights: • A decomposition method is proposed to solve the NCUC with AC power flow constraints • The master problem considers active power, reactive power and transmission losses. • OPF-based subproblems check the AC feasibility using parallel computing techniques. • An effective feedback constraint interacts between the master problem and subproblem. • Computational efficiency is significantly improved with satisfactory accuracy

  7. Analysis of data obtained in two-phase flow tests of primary heat transport pumps

    International Nuclear Information System (INIS)

    Currie, T.C.

    1986-06-01

    This report analyzes data obtained in two-phase flow tests of primary heat transport pumps performed during the period 1980-1983. Phenomena which have been known to cause pump-induced flow oscillations in pressurized piping systems under two-phase conditions are reviewed and the data analyzed to determine whether any of the identified phenomena could have been responsible for the instabilities observed in those tests. Tentative explanations for the most severe instabilities are given based on those analyses. It is shown that suction pipe geometry probably plays an important role in promoting instabilities, so additional experiments to investigate the effect of suction pipe geometry on the stability of flow in a closed pipe loop under two-phase conditions are recommended

  8. CFD analysis for the hydrogen transport in the primary contention of a BWR using the codes OpenFOAM and Gas-Flow

    International Nuclear Information System (INIS)

    Jimenez P, D. A.

    2014-01-01

    limited number of semi-empirical data, and instead, mathematical relationships are used taking into account the various physical phenomena as well the interactions that occur among them, such as heat transfer between the fluid and the solid walls condensation of water vapor on the walls, the turbulent effects in areas of restricted passage, etc. Taking into account these advantages, this study presents a qualitative and quantitative comparison between the CFD codes OpenFOAM and Gas-Flow related to the transport phenomena of Hydrogen and other gases in the primary containment of a BWR reactor. Gas-Flow is a code of commercial license that is well validated, developed in Germany to analyze the transport of gases in nuclear reactor containments. On the other hand, OpenFOAM is an open source CFD code offering several solvers for different phenomena assessments, in this work, the reacting Foam solver is used because it has a strong similarity to the intended application of Hydrogen transport. In this thesis the results obtained using the reacting Foam solver of OpenFOAM for the calculation of transport of Hydrogen are compared with the results of the Gas-Flow code in order to assess if it is feasible to use the open source code OpenFOAM in the case of Hydrogen transport in primary containment of a BWR reactor. Some differences in the qualitative and quantitative results from both codes were found, the differences (with a maximum error rate of 4%) in the quantitative results were found are small and are considered more than acceptable for this type of analysis, moreover, these differences are mainly attributed to the transport models used, mainly because OpenFOAM uses a homogeneous mixture model and Gas-Flow a heterogeneous one. Implementing appropriate solvers in codes like OpenFOAM has the goal to develop own tools that are applicable to the transport of Hydrogen in the primary containment of a BWR reactor and thus, to gain some independence while not relying on commercial

  9. The Use of Energy in Malaysia: Tracing Energy Flows from Primary Source to End Use

    OpenAIRE

    Chinhao Chong; Weidou Ni; Linwei Ma; Pei Liu; Zheng Li

    2015-01-01

    Malaysia is a rapidly developing country in Southeast Asia that aims to achieve high-income country status by 2020; its economic growth is highly dependent on its abundant energy resources, especially natural gas and crude oil. In this paper, a complete picture of Malaysia’s energy use from primary source to end use is presented by mapping a Sankey diagram of Malaysia’s energy flows, together with ongoing trends analysis of the main factors influencing the energy flows. The results indicate t...

  10. Applying organizational behavior theory to primary care.

    Science.gov (United States)

    Mullangi, Samyukta; Saint, Sanjay

    2017-03-01

    Addressing the mounting primary care shortage in the United States has been a focus of educators and policy makers, especially with the passage of the Affordable Care Act in 2010 and the Medicare Access and CHIP Reauthorization Act in 2015, placing increased pressure on the system. The Association of American Medical Colleges recently projected a shortage of as many as 65,000 primary care physicians by 2025, in part because fewer than 20% of medical students are picking primary care for a career. We examined the issue of attracting medical students to primary care through the lens of organizational behavior theory. Assuming there are reasons other than lower income potential for why students are inclined against primary care, we applied various principles of the Herzberg 2-factor theory to reimagine the operational flow and design of primary care. We conclude by proposing several solutions to enrich the job, such as decreasing documentation requirements, reducing the emphasis on specialty consultations, and elevating physicians to a supervisory role.

  11. Primary versus secondary hypertension in children followed up at an outpatient tertiary unit.

    Science.gov (United States)

    Gomes, Romina S; Quirino, Isabel G; Pereira, Regina M; Vitor, Breno M; Leite, Alysson F; Oliveira, Eduardo A; Simões e Silva, Ana Cristina

    2011-03-01

    Childhood hypertension has classically been recognized as a secondary disease. However, primary hypertension also occurs in children. The aim of this study was to compare clinical features of pediatric patients with elevated blood pressure, which were referred to an outpatient tertiary unit, and to detect variables associated with the identification of primary hypertension. The records of 220 patients with hypertension followed between 1996 and 2006 were analyzed. The variable of interest was primary hypertension. Logistic regression analysis was applied to identify clinical variables that were independently associated with primary hypertension. Of 220 patients, 33 (15%) had primary hypertension, and 187 (85%) exhibited secondary hypertension. No statistically significant differences were detected in gender, race, age at diagnosis, and systolic/diastolic blood pressure levels between both groups. After adjustment, four variables at baseline remained independently associated with primary hypertension: absence of signs/symptoms (OR 18.87, 95% CI 6.32-56.29), normal serum creatinine (OR 0.02, 95% CI 0.00-0.27), family history of hypertension (OR 3.03, 95% CI 1.04-8.79), and elevated body weight (OR 1.06, 95% CI 1.02-1.10). The absence of signs/symptoms, normal serum creatinine, family history of hypertension, and overweight/obesity at admission are clues to diagnose primary hypertension in childhood.

  12. Cooling Performance Analysis of ThePrimary Cooling System ReactorTRIGA-2000Bandung

    Science.gov (United States)

    Irianto, I. D.; Dibyo, S.; Bakhri, S.; Sunaryo, G. R.

    2018-02-01

    The conversion of reactor fuel type will affect the heat transfer process resulting from the reactor core to the cooling system. This conversion resulted in changes to the cooling system performance and parameters of operation and design of key components of the reactor coolant system, especially the primary cooling system. The calculation of the operating parameters of the primary cooling system of the reactor TRIGA 2000 Bandung is done using ChemCad Package 6.1.4. The calculation of the operating parameters of the cooling system is based on mass and energy balance in each coolant flow path and unit components. Output calculation is the temperature, pressure and flow rate of the coolant used in the cooling process. The results of a simulation of the performance of the primary cooling system indicate that if the primary cooling system operates with a single pump or coolant mass flow rate of 60 kg/s, it will obtain the reactor inlet and outlet temperature respectively 32.2 °C and 40.2 °C. But if it operates with two pumps with a capacity of 75% or coolant mass flow rate of 90 kg/s, the obtained reactor inlet, and outlet temperature respectively 32.9 °C and 38.2 °C. Both models are qualified as a primary coolant for the primary coolant temperature is still below the permitted limit is 49.0 °C.

  13. Therapeutical effect on blood-flow in three-phase scanning in primary malignant tumours and acute osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Kovacic, K; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine; Cepulic, M [Children` s Hospital, Zagreb (Croatia)

    1994-10-01

    In the studies where the bone scan was limited only to the late static image, the main disadvantage was its nonspecifity. With three-phase bone scan the number of false positive findings was reduced by some peculiar diseases; for instance, acute hematogenous osteomyelitis. It is well known that various diseases, such as nonunion of the fracture, some surgical interventions, avascular necrosis... can imitate acute osteomyelitis on the static image. These diseases can only be differentiated from inflammation by blood-flow. Therefore, in all patients with the diagnosis of primary bone disease tumor, inflammation, trauma, aseptic necrosis... three-phase bone scintigraphy is performed. Here, only the patients with acute osteomyelitis and primary malignant bone tumors will be presented: the basic scintigram was done before the therapy started, and the second one as a part of the follow-up - in some patients during the therapy and in some after its ending. We noticed that the most reliable part of three-phase bone scan responding to the therapy is angioscintigraphy (blood-flow) and in some cases early static (blood-pool) image. These two phases, especially the first one, are in good correlation with the clinic, in contrast to the third phase which is delayed. From the presented cases it could be concluded that in acute osteomyelitis and primary malignant tumors, blood-flow and blood-pool images are unavoidable phases of the bone scanning when we want to correctly evaluate the effects of the therapy. (author).

  14. Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method

    Science.gov (United States)

    Arai, Kenta; Yoshida, Hajime

    2014-10-01

    Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.

  15. Automated Blood Sample Preparation Unit (ABSPU) for Portable Microfluidic Flow Cytometry.

    Science.gov (United States)

    Chaturvedi, Akhil; Gorthi, Sai Siva

    2017-02-01

    Portable microfluidic diagnostic devices, including flow cytometers, are being developed for point-of-care settings, especially in conjunction with inexpensive imaging devices such as mobile phone cameras. However, two pervasive drawbacks of these have been the lack of automated sample preparation processes and cells settling out of sample suspensions, leading to inaccurate results. We report an automated blood sample preparation unit (ABSPU) to prevent blood samples from settling in a reservoir during loading of samples in flow cytometers. This apparatus automates the preanalytical steps of dilution and staining of blood cells prior to microfluidic loading. It employs an assembly with a miniature vibration motor to drive turbulence in a sample reservoir. To validate performance of this system, we present experimental evidence demonstrating prevention of blood cell settling, cell integrity, and staining of cells prior to flow cytometric analysis. This setup is further integrated with a microfluidic imaging flow cytometer to investigate cell count variability. With no need for prior sample preparation, a drop of whole blood can be directly introduced to the setup without premixing with buffers manually. Our results show that integration of this assembly with microfluidic analysis provides a competent automation tool for low-cost point-of-care blood-based diagnostics.

  16. The influence of flow discharge variations on the morphodynamics of a diffluence-confluence unit on the Mekong River

    Science.gov (United States)

    Hackney, Christopher; Darby, Stephen; Parsons, Daniel; Leyland, Julian; Aalto, Rolf; Nicholas, Andrew; Best, Jim

    2017-04-01

    Bifurcations represent key morphological nodes within the channel networks of anabranching and braided fluvial channels, playing an important role in controlling local bed morphology, the routing of sediment and water, and defining the stability of the downstream reaches. Herein, we detail field observations of the three-dimensional flow structure, bed morphological changes and partitioning of both flow discharge and suspended sediment through a large diffluence-confluence unit on the Mekong River, Cambodia, across a range of flow stages (from 13,500 m3 s-1 to 27,000 m3 s-1) over the monsoonal flood-pulse cycle. We show that the discharge asymmetry (a measure of the disparity between discharges distributed down the left and right branches of the bifurcation) varies with flow discharge and that the influence of upstream curvature-induced cross-stream water surface slope and bed morphological changes are first-order controls in modulating the asymmetry in bifurcation discharge. Flow discharge is shown to play a key role in defining the morphodynamics of the diffluence-confluence unit downstream of the bifurcation. Our data show that during high flows (Q 27,000 m3 s-1), the downstream island complex acts as a net sink of suspended sediment (with 2600 kg s-1 being deposited between the diffluence and confluence), whereas during lower flows, on both the rising and falling limbs of the flood wave, the sediment balance is in quasi-equilibrium. We propose, therefore, that the long term stability of the bifurcation, as well as the larger channel planform and morphology of the diffluence-confluence unit, is therefore controlled by annual monsoonal flood pulses and the associated variations in discharge.

  17. Primary circuit and reactor core T-H characteristics determination of WWER 440 reactors

    International Nuclear Information System (INIS)

    Hermansky, J.; Petenyi, V.; Zavodsky, M.

    2010-01-01

    The WWER-440 nuclear fuel vendor permanently improves the assortment of produced nuclear fuel assemblies for achieving better fuel cycle economy and reactor operation safety. During unit refuelling there also could be made some other changes in hydraulic parameters of primary circuit (change of impeller wheels, hydraulic resistance coefficient changes of internal parts of primary circuit, etc.). Therefore it is necessary to determine real coolant flow rate through the reactor during units start-up after their refuelling, and also to have the skilled methodology and computing code for analyzing factors, which affecting the inaccuracy of coolant flow redistribution determination through reactor on flows through separate parts of reactor core in any case of parallel operation of different assembly types. Computing code TH-VCR and CORFLO are used for reactor core characteristics determination for one type of fuel and control assemblies and also in case of parallel operation of different assembly types. The code TH-VCR is able to calculate coolant flow rate for different combinations of three different fuel assembly channel types and three different control assembly channel types. The CORFLO code deals the area of the reactor core which consists of 312 fuel assemblies and 37 control assemblies. Regarding the rotational 60 deg symmetry of reactor core only 1/6 of reactor core with 59 fuel assemblies is taken into account. Computing code CORFLO is verified and validated at this time. Paper presents some results from measurements of coolant flow rate through reactors during start-up after unit refuelling and short description of computing code TH-VCR and CORFLO with some calculated results. (Authors)

  18. Prevalence and factors associated with breast milk donation in banks that receive human milk in primary health care units,

    OpenAIRE

    Meneses, Tatiana Mota Xavier de; Oliveira, Maria Inês Couto de; Boccolini, Cristiano Siqueira

    2017-01-01

    Abstract Objective: To estimate the prevalence and to analyze factors associated with breast milk donation at primary health care units in order to increase the human milk bank reserves. Methods: Cross-sectional study carried out in 2013 in Rio de Janeiro, Brazil. A representative sample of 695 mothers of children younger than 1 year attended to at the nine primary health care units with human milk donation services were interviewed. A hierarchical approach was used to obtain adjusted preva...

  19. Prevalence and factors associated with breast milk donation in banks that receive human milk in primary health care units

    OpenAIRE

    Tatiana Mota Xavier de Meneses; Maria Inês Couto de Oliveira; Cristiano Siqueira Boccolini

    2017-01-01

    Abstract Objective: To estimate the prevalence and to analyze factors associated with breast milk donation at primary health care units in order to increase the human milk bank reserves. Methods: Cross-sectional study carried out in 2013 in Rio de Janeiro, Brazil. A representative sample of 695 mothers of children younger than 1 year attended to at the nine primary health care units with human milk donation services were interviewed. A hierarchical approach was used to obtain adjusted preva...

  20. APPLICATION FEATURES OF SPATIAL CONDUCTOMETRY SENSORS IN MODELLING OF COOLANT FLOW MIXING IN NUCLEAR POWER UNIT EQUIPMENT

    Directory of Open Access Journals (Sweden)

    A. A. Barinov

    2016-01-01

    Full Text Available Coolant flow mixing processes with different temperatures and concentrations of diluted additives widely known in nuclear power units operation. In some cases these processes make essential impact on the resource and behavior of the nuclear unit during transient and emergency situations. The aim of the study was creation of measurement system and test facility to carry out basic tests and to embed spatial conductometry method in investigation practice of turbulent coolant flows. In the course of investigation measurement system with sensors and experimental facility was designed, several first tests were carried out. A special attention was dedicated to calibration and clarification of conductometry sensor application methodologies in studies of turbulent flow characteristics. Investigations involved method of electrically contrast tracer jet with concurrent flow in closed channel of round crosssection. The measurements include both averaged and unsteady realizations of measurement signal. Experimental data processing shows good agreement with other tests acquired from another measurement systems based on different physical principles. Calibration functions were acquired, methodical basis of spatial conductometry measurement system application was created. Gathered experience of spatial sensor application made it possible to formulate the principles of further investigation that involve large-scale models of nuclear unit equipment. Spatial wire-mesh sensors proved to be a perspective type of eddy resolving measurement devices.

  1. A distributed control algorithm for internal flow management in a multi-zone climate unit

    NARCIS (Netherlands)

    Persis, C. De; Jessen, J.J.; Izadi-Zamanabadi, R.; Schiøler, H.

    2008-01-01

    We examine a distributed control problem for internal flow management in a multi-zone climate unit. The problem consists of guaranteeing prescribed indoor climate conditions in a cascade connection of an arbitrarily large number of communicating zones, in which air masses are exchanged to redirect

  2. Turbulent Mixing of Primary and Secondary Flow Streams in a Rocket-Based Combined Cycle Engine

    Science.gov (United States)

    Cramer, J. M.; Greene, M. U.; Pal, S.; Santoro, R. J.; Turner, Jim (Technical Monitor)

    2002-01-01

    This viewgraph presentation gives an overview of the turbulent mixing of primary and secondary flow streams in a rocket-based combined cycle (RBCC) engine. A significant RBCC ejector mode database has been generated, detailing single and twin thruster configurations and global and local measurements. On-going analysis and correlation efforts include Marshall Space Flight Center computational fluid dynamics modeling and turbulent shear layer analysis. Potential follow-on activities include detailed measurements of air flow static pressure and velocity profiles, investigations into other thruster spacing configurations, performing a fundamental shear layer mixing study, and demonstrating single-shot Raman measurements.

  3. Performance analysis of vortex based mixers for confined flows

    Science.gov (United States)

    Buschhagen, Timo

    The hybrid rocket is still sparsely employed within major space or defense projects due to their relatively poor combustion efficiency and low fuel grain regression rate. Although hybrid rockets can claim advantages in safety, environmental and performance aspects against established solid and liquid propellant systems, the boundary layer combustion process and the diffusion based mixing within a hybrid rocket grain port leaves the core flow unmixed and limits the system performance. One principle used to enhance the mixing of gaseous flows is to induce streamwise vorticity. The counter-rotating vortex pair (CVP) mixer utilizes this principle and introduces two vortices into a confined flow, generating a stirring motion in order to transport near wall media towards the core and vice versa. Recent studies investigated the velocity field introduced by this type of swirler. The current work is evaluating the mixing performance of the CVP concept, by using an experimental setup to simulate an axial primary pipe flow with a radially entering secondary flow. Hereby the primary flow is altered by the CVP swirler unit. The resulting setup therefore emulates a hybrid rocket motor with a cylindrical single port grain. In order to evaluate the mixing performance the secondary flow concentration at the pipe assembly exit is measured, utilizing a pressure-sensitive paint based procedure.

  4. Reinventing primary care: lessons from Canada for the United States.

    Science.gov (United States)

    Starfield, Barbara

    2010-05-01

    Canada is, in many respects, culturally and economically similar to the United States, and until relatively recently, the two countries had similar health systems. However, since passage of the Canada Health Act in the 1970s, that nation's health statistics have become increasingly superior. Although the costs of Canada's health system are high by international standards, they are much lower than U.S. costs. This paper describes several factors likely to be responsible for Canada's better health at lower cost: universal financial coverage through a so-called single payer; features conducive to a strong primary care infrastructure; and provincial autonomy under general principles set by national law.

  5. Three dimensional calculations of the primary coolant flow in a 900 MW PWR vessel. Numerical simulation of the accurate RCP start-up flow rate

    International Nuclear Information System (INIS)

    Martin, A.; Alvarez, D.; Cases, F.; Stelletta, S.

    1997-06-01

    This report explains the last results about the mixing in the 900 MW PWR vessels. The accurate fluid flow transient, induced by the RCP starting-up, is represented. In a first time, we present the Thermalhydraulic Finite Element Code N3S used for the 3D numerical computations. After that, results obtained for one reactor operation case are given. This case is dealing with the transient mixing of a clear plug in the vessel when one primary pump starts-up. A comparison made between two injection modes; a steady state fluid flow conditions or the accurate RCP transient fluid flow conditions. The results giving the local minimum of concentration and the time response of the mean concentration at the core inlet are compared. The results show the real importance of the unsteadiness characteristics of the fluid flow transport of the clear water plug. (author)

  6. Heat Flow and Geothermal Potential in the South-Central United States

    International Nuclear Information System (INIS)

    Negraru, Petru T.; Blackwell, David D.; Erkan, Kamil

    2008-01-01

    Geothermal exploration is typically limited to high-grade hydrothermal reservoirs that are usually found in the western United States, yet large areas with subsurface temperatures above 150 deg. C at economic drilling depths can be found east of the Rocky Mountains. The object of this paper is to present new heat flow data and to evaluate the geothermal potential of Texas and adjacent areas. The new data show that, west of the Ouachita Thrust Belt, the heat flow values are lower than east of the fault zone. Basement heat flow values for the Palo Duro and Fort Worth Basins are below 50 mW/m 2 while, in the frontal zone of the belt, they can exceed 60 mW/m 2 . Further east, along the Balcones fault system the heat flow is in general higher than 55 mW/m 2 . The eastern most heat flow sites are in Louisiana and they show very high heat flow (over 80 mW/m 2 ), which is associated with the apparently highly radioactive basement of the Sabine uplift. The geothermal resource in this area is large and diverse, and can be divided in high grade (temperature above 150 deg. C) convective systems, conductive based enhanced geothermal systems and geothermal/geopressured systems. One of the most attractive areas east of the cordillera extends from eastern Texas across Louisiana and Arkansas to western Mississippi. Here temperatures reach exploitation range at depths below 4 km, and tapping such a resource from shut in hydrocarbon fields is relatively easy. The initial costs of the development can be greatly reduced if existing hydrocarbon infrastructure is used, and therefore using shut-in hydrocarbon fields for geothermal purposes should not be neglected

  7. Primary standards for measuring flow rates from 100 nl/min to 1 ml/min - gravimetric principle.

    Science.gov (United States)

    Bissig, Hugo; Petter, Harm Tido; Lucas, Peter; Batista, Elsa; Filipe, Eduarda; Almeida, Nelson; Ribeiro, Luis Filipe; Gala, João; Martins, Rui; Savanier, Benoit; Ogheard, Florestan; Niemann, Anders Koustrup; Lötters, Joost; Sparreboom, Wouter

    2015-08-01

    Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.

  8. Modelling of steam condensation in the primary flow channel of a gas-heated steam generator

    International Nuclear Information System (INIS)

    Kawamura, H.; Meister, G.

    1982-10-01

    A new simulation code has been developed for the analysis of steam ingress accidents in high temperatures reactors which evaluates the heat transfer in a steam generator headed by a mixture of helium and water steam. Special emphasis is laid on the analysis of steam condensation in the primary circuit of the steam generator. The code takes wall and bulk condensation into account. A new method is proposed to describe the entrainment of water droplets in the primary gas flow. Some typical results are given. Steam condensation in the primary channel may have a significant effect on temperature distributions. The effect on the heat transferred by the steam generator, however, is found to be not so prominent as might be expected. The reason is discussed. A simplified code will also be described, which gives results with reasonable accuracy within much shorter execution times. This code may be used as a program module in a program simulating the total primary circuit of a high temperature reactor. (orig.) [de

  9. [Gait, balance and independence rehabilitation program in elderly adults in a primary care unit].

    Science.gov (United States)

    Espinosa-Cuervo, Gisela; López-Roldán, Verónica Miriam; Escobar-Rodríguez, David Alvaro; Conde-Embarcadero, Margarita; Trejo-León, Gerardo; González-Carmona, Beatriz

    2013-01-01

    to evaluate the effect of a supervised rehabilitation program to improve gait, balance and independence in elderly patients attending a family medicine unit. we conducted a quasi-experimental study over a period of four weeks in a group of 72 patients older than 65 years. a supervised program regarding the risk factors for falling, and balance, gait, coordination and oculovestibular system, the modalities to be done two or three times a week in the primary care unit or at home. An analysis of both tests was performed by "up and go," Tinetti scale and the Katz index. "intention to treat" and "by protocol." mean age was 72 ± 5 years, 67.8% were female and 81.9% of the patients completed the program. A significant clinical improvement with statistical level were evident for gait and balance (p = 0.001), independence showed only clinical improvement (p = 0.083). The efficacy for periodicity (two or three times/week) and performance place showed same clinical improvement and statistical level for gait and balance (p = 0.001 to 0.003) and independence showed only clinical improvement (p = 0.317 to 0.991). an integral rehabilitation program improved gait, balance and clinical independence significantly. The supervised program is applicable and can be reproduced at primary care unit or home for geriatric care and preventive actions.

  10. Evaluation of tests for coastdown of reactor coolant flow and measure of primary circuit flow of Angra-1 nuclear power plant

    International Nuclear Information System (INIS)

    Galetti, M.R.S.; Camargo, C.T.M.; Pontedeiro, A.C.

    1987-05-01

    The Angra 1 Nuclear Power Plant first reload license was issued after several technical discussions among CNEN, FURNAS and KWU. During the license process CNEN has established that the plant could return to anormal operation if the requirements described in the letter CNEN-DExL-C 06/86 were satisfied. The requirements according to the CNEN Transient and Thermohydraulic Group Analysis were to do again the following tests: 'Primary Flow Measurement' to check if the excess flow measured in the first cycle was held; and Pump Coastdown' to check if the Westinghouse and KWU fuel elements are thermo-hydraulicaly compatibles during transients. The mixed core must keep at least the same safety margin presented on Angra 1 FSAR for the original core. The tests and the analysis of results are described. (Author) [pt

  11. Analysis of the flow at a T-bifurcation for a ternary unit

    International Nuclear Information System (INIS)

    Campero, P; Beck, J; Jung, A

    2014-01-01

    The motivation of this research is to understand the flow behavior through a 90° T- type bifurcation, which connects a Francis turbine and the storage pump of a ternary unit, under different operating conditions (namely turbine, pump and hydraulic short-circuit operation). As a first step a CFD optimization process to define the hydraulic geometry of the bifurcation was performed. The CFD results show the complexity of the flow through the bifurcation, especially under hydraulic short-circuit operation. Therefore, it was decided to perform experimental investigations in addition to the CFD analysis, in order to get a better understanding of the flow. The aim of these studies was to investigate the flow development upstream and downstream the bifurcation, the estimation of the bifurcation loss coefficients and also to provide comprehensive data of the flow behavior for the whole operating range of the machine. In order to evaluate the development of the velocity field Stereo Particle Image Velocimetry (S-PIV) measurements at different sections upstream and downstream of the bifurcation on the main penstock and Laser Doppler Anemometrie (LDA) measurements at bifurcation inlet were performed. This paper presents the CFD results obtained for the final design for different operating conditions, the model test procedures and the model test results with special attention to: 1) The bifurcation head loss coefficients, and their extrapolation to prototype conditions, 2) S-PIV and LDA measurements. Additionally, criteria to define the minimal uniformity conditions for the velocity profiles entering the turbine are evaluated. Finally, based on the gathered flow information a better understanding to define the preferred location of a bifurcation is gained and can be applied to future projects

  12. Variable partitioning of flow and sediment transfer through a large river diffluence-confluence unit across a monsoonal flood pulse

    Science.gov (United States)

    Hackney, C. R.; Aalto, R. E.; Darby, S. E.; Parsons, D. R.; Leyland, J.; Nicholas, A. P.; Best, J.

    2016-12-01

    Bifurcations represent key morphological nodes within the channel networks of anabranching and braided fluvial channels, playing an important role in controlling local bed morphology, the routing of sediment and water, and defining the stability of the downstream reaches. Herein, we detail field observations of the three-dimensional flow structure, bed morphological changes and partitioning of both flow discharge and suspended sediment through a large diffluence-confluence unit on the Mekong River, Cambodia, across a range of flow stages (from 13,500 m3 s-1 to 27,000 m3 s-1) over the monsoonal flood-pulse cycle. We show that the discharge asymmetry (a measure of the disparity between discharges distributed down the left and right branches of the bifurcation) varies with flow discharge and that the influence of upstream curvature-induced cross-stream water surface slope and bed morphological changes are first-order controls in modulating the asymmetry in bifurcation discharge. Flow discharge is shown to play a key role in defining the morphodynamics of the diffluence-confluence unit downstream of the bifurcation. Our data show that during peak flows (Q 27,000 m3 s-1), the downstream island complex acts as a net sink of suspended sediment (with 2600 kg s-1 being deposited between the diffluence and confluence), whereas during lower flows, on both the rising and falling limbs of the flood wave, the sediment balance is in quasi-equilibrium. We propose a new conceptual model of bifurcation stability that incorporates varying flood discharge and in which the long term stability of the bifurcation, as well as the larger channel planform and morphology of the diffluence-confluence unit, are controlled by the variations in flood discharge.

  13. The effect of commercial policy on international migration flows: the case of the United States and Mexico.

    Science.gov (United States)

    Hill, J K; Mendez, J A

    1984-08-01

    "Microeconomic simulations are performed to determine the impact of liberalized commodity trade on Mexican immigrant supply to the United States. The results suggest that a removal of trade barriers will reduce migration flows, but that the reduction will be fairly modest. Specifically, if both countries move from the levels of protection characteristic of the mid-1960s to completely free trade, the ratio of real U.S.-Mexican wages falls by roughly 18 percent. Using an upper bound for the range of empirical estimates of the wage elasticity of immigrant supply, this implies a maximum reduction in migration flows of 35 percent. A unilateral elimination of trade barriers by the United States reduces Mexican immigrant supply by a maximum of 14 percent." excerpt

  14. Impact of trucking network flow on preferred biorefinery locations in the southern United States

    Science.gov (United States)

    Timothy M. Young; Lee D. Han; James H. Perdue; Stephanie R. Hargrove; Frank M. Guess; Xia Huang; Chung-Hao Chen

    2017-01-01

    The impact of the trucking transportation network flow was modeled for the southern United States. The study addresses a gap in existing research by applying a Bayesian logistic regression and Geographic Information System (GIS) geospatial analysis to predict biorefinery site locations. A one-way trucking cost assuming a 128.8 km (80-mile) haul distance was estimated...

  15. Using discrete event simulation to compare the performance of family health unit and primary health care centre organizational models in Portugal.

    Science.gov (United States)

    Fialho, André S; Oliveira, Mónica D; Sá, Armando B

    2011-10-15

    Recent reforms in Portugal aimed at strengthening the role of the primary care system, in order to improve the quality of the health care system. Since 2006 new policies aiming to change the organization, incentive structures and funding of the primary health care sector were designed, promoting the evolution of traditional primary health care centres (PHCCs) into a new type of organizational unit--family health units (FHUs). This study aimed to compare performances of PHCC and FHU organizational models and to assess the potential gains from converting PHCCs into FHUs. Stochastic discrete event simulation models for the two types of organizational models were designed and implemented using Simul8 software. These models were applied to data from nineteen primary care units in three municipalities of the Greater Lisbon area. The conversion of PHCCs into FHUs seems to have the potential to generate substantial improvements in productivity and accessibility, while not having a significant impact on costs. This conversion might entail a 45% reduction in the average number of days required to obtain a medical appointment and a 7% and 9% increase in the average number of medical and nursing consultations, respectively. Reorganization of PHCC into FHUs might increase accessibility of patients to services and efficiency in the provision of primary care services.

  16. Simulation-based evaluation of the performance of the F test in a linear multilevel model setting with sparseness at the level of the primary unit.

    Science.gov (United States)

    Bruyndonckx, Robin; Aerts, Marc; Hens, Niel

    2016-09-01

    In a linear multilevel model, significance of all fixed effects can be determined using F tests under maximum likelihood (ML) or restricted maximum likelihood (REML). In this paper, we demonstrate that in the presence of primary unit sparseness, the performance of the F test under both REML and ML is rather poor. Using simulations based on the structure of a data example on ceftriaxone consumption in hospitalized children, we studied variability, type I error rate and power in scenarios with a varying number of secondary units within the primary units. In general, the variability in the estimates for the effect of the primary unit decreased as the number of secondary units increased. In the presence of singletons (i.e., only one secondary unit within a primary unit), REML consistently outperformed ML, although even under REML the performance of the F test was found inadequate. When modeling the primary unit as a random effect, the power was lower while the type I error rate was unstable. The options of dropping, regrouping, or splitting the singletons could solve either the problem of a high type I error rate or a low power, while worsening the other. The permutation test appeared to be a valid alternative as it outperformed the F test, especially under REML. We conclude that in the presence of singletons, one should be careful in using the F test to determine the significance of the fixed effects, and propose the permutation test (under REML) as an alternative. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Analisis Potensi Ledakan dan Kebakaran Primary Reformer sebagai Unit Proses Produksi Amonia di PT. X

    Directory of Open Access Journals (Sweden)

    Resti Ayu Lestari

    2016-12-01

    Full Text Available Peningkatan industri pupuk di dunia berimplikasi pada peningkatan jumlah industri amonia. Amonia memegang peranan penting pada proses produksi pupuk dalam hal penyediaan nitrogen. Proses pembuatan amonia melibatkan bahan baku berupa gas alam yang bersifat flammable dengan temperatur dan tekanan yang tinggi dalam setiap tahapan prosesnya. Primary reformer merupakan salah satu peralatan proses dalam produksi amonia dengan temperatur dan tekanan paling tinggi serta paling berisiko mengalami kegagalan yang dapat mengakibatkan terjadinya kebakaran/ledakan. Primary reformer berperan sebagai salah satu tahapan pemurnian gas alam dengan hasil berupa karbon monoksida. Identifikasi bahaya pada unit primary reformer dilakukan dengan menggunakan metode Fault Tree Analysis (FTA. Hasil analisis FTA menghasilkan bahwa sumber bahaya dari ledakan primary reformer dapat ditinjau dari faktor teknis dan faktor non teknis. Faktor non teknis menyumbang 74% dari penyebab terjadinya ledakan/kebakaran pada primary reformer. Hasil analisis risiko ledakan/kebakaran pada primary reformer dilakukan dengan menggunakan Dow’s Fire & Explosion Index  dengan hasil radius area dampak adalah 51 meter. Nilai kerugian finansial mencapai US$ 23.640.285 dengan kerugian hari kerja minimal adalah 138 hari. Perangkat lunak Arial Location of Hazardous Atmospheres menghasilkan radius ledakan dengan dampak terkecil yaitu dapat memecahkan kaca jendela/pintu (0,5 psi adalah 73 m dari primary reformer. Radius ledakan dengan kekuatan ledakan 1 psi (meruntuhkan rumah/perkantoran adalah 48 m dari primary reformer.

  18. Disinfection of an advanced primary effluent with peracetic acid and ultraviolet combined treatment: a continuous-flow pilot plant study.

    Science.gov (United States)

    González, Abelardo; Gehr, Ronald; Vaca, Mabel; López, Raymundo

    2012-03-01

    Disinfection of an advanced primary effluent using a continuous-flow combined peracetic acid/ultraviolet (PAA/UV) radiation system was evaluated. The purpose was to determine whether the maximum microbial content, established under Mexican standards for treated wastewaters meant for reuse--less than 240 most probable number fecal coliforms (FC)/100 mL--could be feasibly accomplished using either disinfectant individually, or the combined PAA/UV system. This meant achieving reduction of up to 5 logs, considering initial concentrations of 6.4 x 10(+6) to 5.8 x 10(+7) colony forming units/100 mL. During the tests performed under these experiments, total coliforms (TC) were counted because FC, at the most, will be equal to TC. Peracetic acid disinfection achieved less than 1.5 logs TC reduction when the C(t) x t product was less than 2.26 mg x minimum (min)/L; 3.8 logs for C(t) x t 4.40 mg x min/L; and 5.9 logs for C(t) x t 24.2 mg x min/L. In continuous-flow UV irradiation tests, at a low-operating flow (21 L/min; conditions which produced an average UV fluence of 13.0 mJ/cm2), the highest TC reduction was close to 2.5 logs. The only condition that produced a disinfection efficiency of approximately 5 logs, when both disinfection agents were used together, was the combined process dosing 30 mg PAA/L at a pilot plant flow of 21 L/min and contact time of 10 minutes to attain an average C(t) x t product of 24.2 mg x min/L and an average UV fluence of 13 mJ/cm2. There was no conclusive evidence of a synergistic effect when both disinfectants were employed in combination as compared to the individual effects achieved when used separately, but this does not take into account the nonlinearity (tailing-off) of the dose-response curve.

  19. Overview of flow studies for recycling metal commodities in the United States

    Science.gov (United States)

    Sibley, Scott F.

    2011-01-01

    Metal supply consists of primary material from a mining operation and secondary material, which is composed of new and old scrap. Recycling, which is the use of secondary material, can contribute significantly to metal production, sometimes accounting for more than 50 percent of raw material supply. From 2001 to 2011, U.S. Geological Survey (USGS) scientists studied 26 metals to ascertain the status and magnitude of their recycling industries. The results were published in chapters A-Z of USGS Circular 1196, entitled, "Flow Studies for Recycling Metal Commodities in the United States." These metals were aluminum (chapter W), antimony (Q), beryllium (P), cadmium (O), chromium (C), cobalt (M), columbium (niobium) (I), copper (X), germanium (V), gold (A), iron and steel (G), lead (F), magnesium (E), manganese (H), mercury (U), molybdenum (L), nickel (Z), platinum (B), selenium (T), silver (N), tantalum (J), tin (K), titanium (Y), tungsten (R), vanadium (S), and zinc (D). Each metal commodity was assigned to a single year: chapters A-M have recycling data for 1998; chapters N-R and U-W have data for 2000, and chapters S, T, and X-Z have data for 2004. This 27th chapter of Circular 1196 is called AA; it includes salient data from each study described in chapters A-Z, along with an analysis of overall trends of metals recycling in the United States during 1998 through 2004 and additional up-to-date reviews of selected metal recycling industries from 1991 through 2008. In the United States for these metals in 1998, 2000, and 2004 (each metal commodity assigned to a single year), 84 million metric tons (Mt) of old scrap was generated. Unrecovered old scrap totaled 43 Mt (about 51 percent of old scrap generated, OSG), old scrap consumed was 38 Mt (about 45 percent of OSG), and net old scrap exports were 3.3 Mt (about 4 percent of OSG). Therefore, there was significant potential for increased recovery from scrap. The total old scrap supply was 88 Mt, and the overall new

  20. Evidence Support and Guidelines for Using Heated, Humidified, High-Flow Nasal Cannulae in Neonatology: Oxford Nasal High-Flow Therapy Meeting, 2015.

    Science.gov (United States)

    Roehr, Charles C; Yoder, Bradley A; Davis, Peter G; Ives, Kevin

    2016-12-01

    Nasal high-flow therapy (nHFT) has become a popular form of noninvasive respiratory support in neonatal intensive care units. A meeting held in Oxford, UK, in June 2015 examined the evidence base and proposed a consensus statement. In summary, nHFT is effective for support of preterm infants following extubation. There is growing evidence evaluating its use in the primary treatment of respiratory distress. Further study is needed to assess which clinical conditions are most amenable to nHFT support, the most effective flow rates, and escalation and weaning strategies. Its suitability as first-line treatment needs to be further evaluated. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Breaking down the silos to decrease internal diversions and patient flow delays.

    Science.gov (United States)

    Driscoll, Molly; Tobis, Kristen; Gurka, David; Serafin, Frederick; Carlson, Elizabeth

    2015-01-01

    Hospitals strive to admit patients to the units where caregiver competencies align with the patient's condition. When the hospital's census peaks, internal diversions and the associated risks increase, which are intensified when silos exist, as segregated care negatively impacts collaboration and patient safety. In this study, a 600+-bed academic, tertiary care specialty hospital experienced an increase in internal diversions. Within the neuroscience service line, emergent neuroscience transfers from outside hospitals had been declined or internally diverted because of capacity limitations. Formalized processes for improving collaboration between health care providers related to capacity issues were required to decrease internal diversions and improve patient flow and patient safety. A pilot project was conducted on neuroscience units during a process improvement initiative. A hospital-wide internal diversion plan was developed, identifying primary and secondary placement options for all patients requiring hospitalization to support patient flow and patient safety. Forecasting tools were developed to provide units' leadership with current information on expected admissions. Daily capacity huddles were instituted to increase collaboration between patient care units. The interventions trialed during the pilot decreased internal diversions and improved patient flow. The improved collaboration resulted in an 80% decrease in declinations of emergent intensive care unit transfers from outside hospitals due to capacity limitations and a 50% decrease in the number of these patients being internally diverted to alternate intensive care units. The interventions implemented minimized internal diversions and improved patient flow. The transparency of the patient placement process led to an increased collaboration between all participants.

  2. Reevaluation of Kori Unit 4 Natural Circulation Test

    Energy Technology Data Exchange (ETDEWEB)

    Yassin, Nassir [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Woo, Sweng Woong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    The simulation results showed that the natural circulation flow developed by density difference was capable of removing decay heat from the fuel rod. The maximum pellet centerline temperature of the hot channel showed large margin to the pellet melting temperature. The maximum coolant temperature in the hot channel was well below the saturation temperature. If steam generators provide heat sink to the primary coolant system and thus natural circulation is maintained, the integrity of the fuel in the core can be sustained with large margin. Passive cooling of reactor is inevitable in case of failures in forced cooling system such as loss of electric power for cooling pumps. Fukushima accident showed the importance of the passive core cooling. During the commissioning test of PWRs, natural circulation test is performed to demonstrate the passive core cooling by natural convection. The driving force for coolant flow is developed by the density deference along the loop multiplied by the gravitation. Using the data from 'natural circulation test' and 'RCS flow coast down test' of Kori Unit 4, fuel behavior was reevaluated by FRAPTRAN code. RCS natural circulation test of Kori Unit 4 was reevaluated by FRAPTYRAN simulation to study the fuel behavior during the flow coast down transient and at the equilibrium condition in which decay heat transport and RCS flow were stabilized.

  3. Primary Teachers' Written Unit Plans in Mathematics and Their Perceptions of Essential Elements of These

    Science.gov (United States)

    Roche, Anne; Clarke, Doug M.; Clarke, David J.; Sullivan, Peter

    2014-01-01

    The content and purpose of written unit plans in mathematics is an under-researched area. In this article, we provide a brief overview of research on teachers' planning processes and the place of mental and written plans. We report on data from a questionnaire completed by 357 teachers from Victorian Catholic primary schools, where we focused on…

  4. Elevated admission microalbuminuria predicts poor myocardial blood flow and 6-month mortality in ST-segment elevation myocardial infarction patients undergoing primary percutaneous coronary intervention.

    Science.gov (United States)

    Chen, Jia Wei; Wang, Yong Liang; Li, Hong Wei

    2012-04-01

    Microalbuminuria (MA) is considered a major risk factor predisposing to cardiovascular morbidity and mortality. Outcomes after percutaneous coronary intervention (PCI) for patients with acute myocardial infarction (AMI) complicated by MA have been well described. However, data regarding admission MA and coronary and myocardial flow are scant. The aims of this study were to evaluate the effects of admission MA on coronary blood flow and prognosis in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary PCI. Did elevated admission microalbuminuria predict poor myocardial blood flow and 6-month mortality in ST-segment elevation myocardial infarction patients undergoing primary percutaneous coronary intervention? A total of 247 patients undergoing primary PCI for STEMI within 12 hours after symptom onset were studied. Patients were divided into 2 groups according to admission urinary albumin extraction rate (UAER): (1) an MA group (UAER 20-200 µg/min), and (2) a normoalbuminuria (NA) group (UAER < 20 µg/min). Microalbuminuria was observed in 108 patients. Univariate analyses showed statistical differences between the NA and MA groups in serum creatine level, plasma glucose level, and peak creatine kinase level on presentation. Thrombolysis In Myocardial Infarction (TIMI) flow grades (TFGs) 0-2 in the MA group were more frequent (9.4% vs 21.2%, P < 0.05) than in the NA group, and corrected TIMI frame count was higher (23.9 ± 18.5 vs 29.8 ± 23.5, P < 0.05). Admission MA was an independent predictor of poor myocardial perfusion (adjusted relative risk: 3.14, 95% confidence interval: 0.99-6.78) and a higher rate of 6-month mortality in STEMI patients undergoing primary PCI (adjusted relative risk: 1.58, 95% confidence interval: 0.74-3.39). Admission MA levels are associated with impaired myocardial flow and poor prognosis in STEMI patients undergoing primary PCI. © 2012 Wiley Periodicals, Inc.

  5. Counter-rotating type axial flow pump unit in turbine mode for micro grid system

    International Nuclear Information System (INIS)

    Kasahara, R; Takano, G; Komaki, K; Murakami, T; Kanemoto, T

    2012-01-01

    Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. This serial research proposes the hybrid power system combined the wind power unit with the pump-turbine unit, to provide the constant output for the grid system, even at the suddenly fluctuating/turbulent wind. In the pumping mode, the pump should operate unsteadily at not only the normal but also the partial discharge. The operation may be unstable in the rising portion of the head characteristics at the lower discharge, and/or bring the cavitation at the low suction head. To simultaneously overcome both weak points, the authors have proposed a superior pump unit that is composed of counter-rotating type impellers and a peculiar motor with double rotational armatures. This paper discusses the operation at the turbine mode of the above unit. It is concluded with the numerical simulations that this type unit can be also operated acceptably at the turbine mode, because the unit works so as to coincide the angular momentum change through the front runners/impellers with that thorough the rear runners/impellers, namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.

  6. Considerations in providing purification flows for 500 MWe PHWR primary circuits

    International Nuclear Information System (INIS)

    Sharma, A.K.; Goswami, S.; Bapat, C.N.; Sharma, V.K.

    1995-01-01

    The purpose of the purification system is to keep the primary heat transport (PHT) system clean by removing traces of impurities arising due to corrosion of the carbon steel pipes and heat transfer surfaces and erosion/corrosion of valve trims, pipes and mechanical seals or due to presence of soluble or insoluble fission products. These impurities are undesirable because they are usually radioactive, either naturally or through activation by the neutron flux as they are carried by the coolant through the reactor core. The purification system minimizes the probability of generation of radioactive impurities by controlling the chemistry of PHT coolant so that corrosion is minimum. Various considerations for providing the requisite purification flow to fulfill the above functions for a typical 500 MWe PHWR are presented. (author). 4 refs., 2 tabs., 2 figs

  7. A flow test for calibrating 177 core tubes of 1/5-scale reactor flow model for Yonggwang nuclear units 3 and 4

    International Nuclear Information System (INIS)

    Lee, Byung Jin; Jang, Ho Cheol; Cheong, Jong Sik; Kuh, Jung Eui

    1990-01-01

    A flow test was performed to find out the hydraulic characteristics of every one of 177 core tubes, representing a fuel assembly respectively, as a preparatory step of 1/5 scale reactor flow model test for Yonggwang Nuclear Units (hereafter YGN) 3 and 4. The axial hydraulic resistance of the fuel assembly was simulated in the square core tube with six orifice plates positioned along the tube length; core support structure below each fuel assembly was done in the core upstream geometry section of the test loop. For each core tube the pressure differentials across the inlet, exit orifice plate and overall tube length were measured, along with the flow rates and temperatures of the test fluid. The measured pressure drops were converted to pressure loss or flow metering coefficients. The metering coefficient of the inlet orifice plate was sensitive to the configuration and location of the upstream geometry. The hydraulic resistance of the core tubes were reasonably coincided with a target value and consistent. The polynomial curve fits of the calibrated coefficients for the 177 core tubes were obtained with reasonable data scatters

  8. Updated logistic regression equations for the calculation of post-fire debris-flow likelihood in the western United States

    Science.gov (United States)

    Staley, Dennis M.; Negri, Jacquelyn A.; Kean, Jason W.; Laber, Jayme L.; Tillery, Anne C.; Youberg, Ann M.

    2016-06-30

    Wildfire can significantly alter the hydrologic response of a watershed to the extent that even modest rainstorms can generate dangerous flash floods and debris flows. To reduce public exposure to hazard, the U.S. Geological Survey produces post-fire debris-flow hazard assessments for select fires in the western United States. We use publicly available geospatial data describing basin morphology, burn severity, soil properties, and rainfall characteristics to estimate the statistical likelihood that debris flows will occur in response to a storm of a given rainfall intensity. Using an empirical database and refined geospatial analysis methods, we defined new equations for the prediction of debris-flow likelihood using logistic regression methods. We showed that the new logistic regression model outperformed previous models used to predict debris-flow likelihood.

  9. On possibility of application of the parallel-mixed type coolant flow scheme to NPP steam generators linked with superheaters

    International Nuclear Information System (INIS)

    Malkis, V.A.; Lokshin, V.A.

    1983-01-01

    Optimum distribution of the coolant straight-through flow between the superheater, evaporator and economizer is determined and the parallel-mixed type flow scheme is compared with other schemes. The calculations are performed for the 250 MW(e) steam generator for the WWER-1000 reactor unit the inlet and outlet primary coolant temperature of which is 324 and 290 deg C, respectively, while the feed water and saturation temperatures are 220 and 278.5 deg C, respectively. The rated superheating temperature is 300 deg C. The comparison of different schemes has been performed according to the average temperature head value at the steam-generator under the condition of equality as well as essential difference in the heat transfer coefficients in certain steam-generator sections. The calculations have shown that the use of parallel-mixed type flow permits to essentially increase the temperature head of the steam generator. At a constant heat transfer coefficient in all steam generator sections the highest temperature head is reached. At relative flow rates in the steam generator, economizer and evaporator equal to 6, 8 and 86%, respectively. The superheated steam generator temperature head in this case by 12% exceeds the temperature head of the WWER-1000 reactor unit wet steam generator. In case of heat transfer coefficient reduction in the superheater by a factor of three, the choice of the primary coolant, optimum distribution permits to maintain the steam generator temperature head at the level of the WWER-1000 reactor unit wet-steam steam generator. The use of the parallel-mixed type flow scheme permits to design a steam generator of slightly superheated steam for the parameters of the WWER-1000 unit

  10. Q-factor of coolant flow in the primary circuit of NPP with pressurised water reactors

    International Nuclear Information System (INIS)

    Proskuryakov, K.N.; Belikov, S.O.; Novikov, K.S.

    2011-01-01

    Systems of preoperational vibration dynamic monitoring in of WWER are presented. The results of measurements during commission of NPP with WWER are presented. The paper provides the result of the research, that estimation of coolant fluctuations caused by pulse perturbation of pressure in the primary circuit NPP. It is shown that results could be received at known value of a Q - factor of acoustical oscillatory system only. The research demonstrates the results of dependence of the sound speed from the mass steam content in the coolant flow thru reactor core. The worked out results can be used for identification of the reasons of abnormal growth of level of vibrations of fuel assembly, fuel rod, equipment and internals, and for forecasting the operation conditions which provide of vibration - acoustical resonances in the primary loop equipment. (author)

  11. Experience of Ko-Ri Unit 1 water chemistry

    International Nuclear Information System (INIS)

    Tae Il Lee

    1983-01-01

    The main focus is placed on operational experience in secondary system water chemistry (especially the steam generator) of the Ko-Ri nuclear power plant Unit 1, Republic of Korea, but primary side chemistry is also discussed. The major concern of secondary water chemistry in a PWR is that the condition of the steam generator be well maintained. Full flow deep bed condensate polishers have recently been installed and operation started in July 1982. Boric acid treatment of the steam generator was stopped and only the all volatile treatment method was used thereafter. A review of steam generator integrity, the chemistry control programme, secondary water quality, etc. is considered to be of great value regarding the operation of Unit 1 and future units now under startup testing or construction in the Republic of Korea. (author)

  12. Global patterns in human consumption of net primary production

    Science.gov (United States)

    Imhoff, Marc L.; Bounoua, Lahouari; Ricketts, Taylor; Loucks, Colby; Harriss, Robert; Lawrence, William T.

    2004-06-01

    The human population and its consumption profoundly affect the Earth's ecosystems. A particularly compelling measure of humanity's cumulative impact is the fraction of the planet's net primary production that we appropriate for our own use. Net primary production-the net amount of solar energy converted to plant organic matter through photosynthesis-can be measured in units of elemental carbon and represents the primary food energy source for the world's ecosystems. Human appropriation of net primary production, apart from leaving less for other species to use, alters the composition of the atmosphere, levels of biodiversity, energy flows within food webs and the provision of important ecosystem services. Here we present a global map showing the amount of net primary production required by humans and compare it to the total amount generated on the landscape. We then derive a spatial balance sheet of net primary production `supply' and `demand' for the world. We show that human appropriation of net primary production varies spatially from almost zero to many times the local primary production. These analyses reveal the uneven footprint of human consumption and related environmental impacts, indicate the degree to which human populations depend on net primary production `imports' and suggest policy options for slowing future growth of human appropriation of net primary production.

  13. Geological Factors Affecting Flow Spatial Continuity in Water Injection of Units Operating in the LGITJ–0102 Ore Body

    Directory of Open Access Journals (Sweden)

    Ilver M. Soto-Loaiza

    2016-05-01

    Full Text Available The objective of the investigation was to identify the geological factors affecting the spatial continuity of the flow during the process of flank water injection in the units operating in the Lower Lagunilla Hydrocarbon Ore Body. This included the evaluation of the recovery factor, the petro-physic properties such as porosity, permeability, water saturation and rock type and quality in each flow unit. it was observed that the rock type of the geologic structure in the ore body is variable. The lowest values for the petro-physic properties were found in the southern area while a high variability of these parameters was observed in the northern and central areas. It was concluded that the northern area has a great potential for the development of new injection projects for petroleum recovery.

  14. An assessment of the energetic flows in a commercial PEM fuel-cell system

    International Nuclear Information System (INIS)

    Jovan, Vladimir; Perne, Matija; Petrovcic, Janko

    2010-01-01

    Some primary issues have not yet been fully investigated on the way towards the commercialization of fuel-cell-based systems (FCS), e.g., their actual efficiency, reliability, safety, degradation, maintainability, etc. This article deals with an estimation of the real energetic flows and the corresponding electrical efficiency of a commercial proton-exchange-membrane fuel-cell hydrogen-fed generator set (PEMFCS). The fuel-cell power system considered here is planned to be the source of both electrical and thermal energy in a mobile dwelling container unit with in-built fuel-cell-based cogeneration system, and for the design of a cogeneration unit the actual amount of disposable energy from the PEMFC unit should be estimated. The assessment of the actual energetic flows, the disposable energy and the consequent electrical efficiency of the case-study PEMFCS is carried out using commercial technical data for the PEMFCS.

  15. Principal component analysis in an experimental cold flow model of a fluid catalytic cracking unit by gammametry

    International Nuclear Information System (INIS)

    Araujo, Janeo Severino C. de; Dantas, Carlos Costa; Santos, Valdemir A. dos; Souza, Jose Edson G. de; Luna-Finkler, Christine L.

    2009-01-01

    The fluid dynamic behavior of riser of a cold flow model of a Fluid Catalytic Cracking Unit (FCCU) was investigated. The experimental data were obtained by the nuclear technique of gamma transmission. A gamma source was placed diametrically opposite to a detector in any straight section of the riser. The gas-solid flow through riser was monitored with a source of Americium-241 what allowed obtaining information of the axial solid concentration without flow disturbance and also identifying the dependence of this concentration profile with several independent variables. The MatLab R and Statistica R software were used. Statistica tool employed was the Principal Components Analysis (PCA), that consisted of the job of the data organization, through two-dimensional head offices to allow extract relevant information about the importance of the independent variables on axial solid concentration in a cold flow riser. The variables investigated were mass flow rate of solid, mass flow rate of gas, pressure in the riser base and the relative height in the riser. The first two components reached about 98 % of accumulated percentage of explained variance. (author)

  16. A Hydrostratigraphic System for Modeling Groundwater Flow and Radionuclide Migration at the Corrective Action Unit Scale, Nevada Test Site and Surrounding Areas, Clark, Lincoln, and Nye Counties, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Prothro, Lance; Drellack Jr., Sigmund; Mercadante, Jennifer

    2009-01-31

    Underground Test Area (UGTA) corrective action unit (CAU) groundwater flow and contaminant transport models of the Nevada Test Site (NTS) and vicinity are built upon hydrostratigraphic framework models (HFMs) that utilize the hydrostratigraphic unit (HSU) as the fundamental modeling component. The delineation and three-dimensional (3-D) modeling of HSUs within the highly complex geologic terrain that is the NTS requires a hydrostratigraphic system that is internally consistent, yet flexible enough to account for overlapping model areas, varied geologic terrain, and the development of multiple alternative HFMs. The UGTA CAU-scale hydrostratigraphic system builds on more than 50 years of geologic and hydrologic work in the NTS region. It includes 76 HSUs developed from nearly 300 stratigraphic units that span more than 570 million years of geologic time, and includes rock units as diverse as marine carbonate and siliciclastic rocks, granitic intrusives, rhyolitic lavas and ash-flow tuffs, and alluvial valley-fill deposits. The UGTA CAU-scale hydrostratigraphic system uses a geology-based approach and two-level classification scheme. The first, or lowest, level of the hydrostratigraphic system is the hydrogeologic unit (HGU). Rocks in a model area are first classified as one of ten HGUs based on the rock’s ability to transmit groundwater (i.e., nature of their porosity and permeability), which at the NTS is mainly a function of the rock’s primary lithology, type and degree of postdepositional alteration, and propensity to fracture. The second, or highest, level within the UGTA CAU-scale hydrostratigraphic system is the HSU, which is the fundamental mapping/modeling unit within UGTA CAU-scale HFMs. HSUs are 3-D bodies that are represented in the finite element mesh for the UGTA groundwater modeling process. HSUs are defined systematically by stratigraphically organizing HGUs of similar character into larger HSUs designations. The careful integration of

  17. A Hydrostratigraphic System for Modeling Groundwater Flow and Radionuclide Migration at the Corrective Action Unit Scale, Nevada Test Site and Surrounding Areas, Clark, Lincoln, and Nye Counties, Nevada

    International Nuclear Information System (INIS)

    Prothro, Lance; Drellack Jr, Sigmund; Mercadante, Jennifer

    2009-01-01

    Underground Test Area (UGTA) corrective action unit (CAU) groundwater flow and contaminant transport models of the Nevada Test Site (NTS) and vicinity are built upon hydrostratigraphic framework models (HFMs) that utilize the hydrostratigraphic unit (HSU) as the fundamental modeling component. The delineation and three-dimensional (3-D) modeling of HSUs within the highly complex geologic terrain that is the NTS requires a hydrostratigraphic system that is internally consistent, yet flexible enough to account for overlapping model areas, varied geologic terrain, and the development of multiple alternative HFMs. The UGTA CAU-scale hydrostratigraphic system builds on more than 50 years of geologic and hydrologic work in the NTS region. It includes 76 HSUs developed from nearly 300 stratigraphic units that span more than 570 million years of geologic time, and includes rock units as diverse as marine carbonate and siliciclastic rocks, granitic intrusives, rhyolitic lavas and ash-flow tuffs, and alluvial valley-fill deposits. The UGTA CAU-scale hydrostratigraphic system uses a geology-based approach and two-level classification scheme. The first, or lowest, level of the hydrostratigraphic system is the hydrogeologic unit (HGU). Rocks in a model area are first classified as one of ten HGUs based on the rock's ability to transmit groundwater (i.e., nature of their porosity and permeability), which at the NTS is mainly a function of the rock's primary lithology, type and degree of postdepositional alteration, and propensity to fracture. The second, or highest, level within the UGTA CAU-scale hydrostratigraphic system is the HSU, which is the fundamental mapping/modeling unit within UGTA CAU-scale HFMs. HSUs are 3-D bodies that are represented in the finite element mesh for the UGTA groundwater modeling process. HSUs are defined systematically by stratigraphically organizing HGUs of similar character into larger HSUs designations. The careful integration of stratigraphic

  18. Prevalence and factors associated with breast milk donation in banks that receive human milk in primary health care units

    Directory of Open Access Journals (Sweden)

    Tatiana Mota Xavier de Meneses

    2017-07-01

    Conclusions: Encouragement to breast milk donation, and information and help provided by primary health care unit professionals to breastfeeding were shown to be important for the practice of human milk donation.

  19. Cell proliferation and apoptosis in the primary enamel knot measured by flow cytometry of laser microdissected samples

    Czech Academy of Sciences Publication Activity Database

    Matalová, Eva; Dubská, L.; Fleischmannová, Jana; Chlastáková, Ivana; Janečková, Eva; Tucker, A. S.

    2010-01-01

    Roč. 55, č. 8 (2010), s. 570-575 ISSN 0003-9969 R&D Projects: GA AV ČR KJB500450802; GA AV ČR IAA600450904; GA ČR GA203/08/1680 Institutional research plan: CEZ:AV0Z50450515 Keywords : Laser capture microdissection * Flow cytometry * Primary enamel knot Subject RIV: EA - Cell Biology Impact factor: 1.463, year: 2010

  20. Flow and pressure profiles for the primary heat transport system of Rajasthan Atomic Power Station for the operation with few isolated reactor channels near the end shield cracks

    Energy Technology Data Exchange (ETDEWEB)

    Gaikwad, A J; Chaki, S K; Sehgal, R L; Venkat Raj, V [Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    The RAPS (Rajasthan Atomic Power Station) unit-1 is now operating at reduced power due to the removal of fifteen fuel channels for repair of south end shield cracks. The power level is restricted to 50% of the full power capacity as a precautionary measure. The relative difference that operation at 50% power and higher power would make to the end shield structure is being currently analysed with a view to operate this reactor at higher power levels. As a prerequisite, a detailed thermal hydraulic analysis is essential to assess the effect of reactor operation with isolated channels on the primary heat transport (PHT) system pressure, flow, temperature. The adequacy of the existing trip set points for the plant operation under this mode is also required to be assessed. In the present study, analysis of the PHT system has been carried out to determine the flow and pressure profiles for the RAPS heat transport system for operation of the reactor with isolated channels. (author). 5 refs., 1 fig., 1 tab.

  1. SOFTWARE SOLUTIONS FOR MEASURING AND FORECASTING THE CASH GENERATING UNIT FLOWS RELATED TO INTANGIBLE ASSETS

    Directory of Open Access Journals (Sweden)

    Veronica R GROSU

    2016-08-01

    Full Text Available In light of the difficulties encountered in assessing the value of the CGU (Cash Generating Unit and of the cash flows associated with goodwill or other intangible assets of a company and after performing the impairment test as provided by the IAS 36-Intangibile Asset and the forecasts related to it, the aim of this paper is to identify and suggest software instruments that would assist in the measurement and forecasting of these elements. The employment of the SPSS and the NeuroShell programmes in analyzing and forecasting the changes in CGU and CGU flows has helped compare the results and the ensuing error margins, thus giving the business entity the possibility to select the best software option, depending on certain variables identified on a micro or a macroeconomic level that may affect the depreciation or the increases in value of the underlying assets for CGU or CGU flows.

  2. Industrial energy-flow management

    International Nuclear Information System (INIS)

    Lampret, Marko; Bukovec, Venceslav; Paternost, Andrej; Krizman, Srecko; Lojk, Vito; Golobic, Iztok

    2007-01-01

    Deregulation of the energy market has created new opportunities for the development of new energy-management methods based on energy assets, risk management, energy efficiency and sustainable development. Industrial energy-flow management in pharmaceutical systems, with a responsible approach to sustainable development, is a complex task. For this reason, an energy-information centre, with over 14,000 online measured data/nodes, was implemented. This paper presents the energy-flow rate, exergy-flow rate and cost-flow rate diagrams, with emphasis on cost-flow rate per energy unit or exergy unit of complex pharmaceutical systems

  3. Cryogenic flow rate measurement with a laser Doppler velocimetry standard

    Science.gov (United States)

    Maury, R.; Strzelecki, A.; Auclercq, C.; Lehot, Y.; Loubat, S.; Chevalier, J.; Ben Rayana, F.

    2018-03-01

    A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame-Exadebit is involved in various research and development programs. Within the framework of the first (2010-2013) and second (2014-2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame-Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame-Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).

  4. Heat exchanger with oscillating flow

    Science.gov (United States)

    Scotti, Stephen J. (Inventor); Blosser, Max L. (Inventor); Camarda, Charles J. (Inventor)

    1993-01-01

    Various heat exchange apparatuses are described in which an oscillating flow of primary coolant is used to dissipate an incident heat flux. The oscillating flow may be imparted by a reciprocating piston, a double action twin reciprocating piston, fluidic oscillators or electromagnetic pumps. The oscillating fluid flows through at least one conduit in either an open loop or a closed loop. A secondary flow of coolant may be used to flow over the outer walls of at least one conduit to remove heat transferred from the primary coolant to the walls of the conduit.

  5. Primary phonological planning units in spoken word production are language-specific: Evidence from an ERP study.

    Science.gov (United States)

    Wang, Jie; Wong, Andus Wing-Kuen; Wang, Suiping; Chen, Hsuan-Chih

    2017-07-19

    It is widely acknowledged in Germanic languages that segments are the primary planning units at the phonological encoding stage of spoken word production. Mixed results, however, have been found in Chinese, and it is still unclear what roles syllables and segments play in planning Chinese spoken word production. In the current study, participants were asked to first prepare and later produce disyllabic Mandarin words upon picture prompts and a response cue while electroencephalogram (EEG) signals were recorded. Each two consecutive pictures implicitly formed a pair of prime and target, whose names shared the same word-initial atonal syllable or the same word-initial segments, or were unrelated in the control conditions. Only syllable repetition induced significant effects on event-related brain potentials (ERPs) after target onset: a widely distributed positivity in the 200- to 400-ms interval and an anterior positivity in the 400- to 600-ms interval. We interpret these to reflect syllable-size representations at the phonological encoding and phonetic encoding stages. Our results provide the first electrophysiological evidence for the distinct role of syllables in producing Mandarin spoken words, supporting a language specificity hypothesis about the primary phonological units in spoken word production.

  6. The coupling of cerebral blood flow and oxygen metabolism with brain activation is similar for simple and complex stimuli in human primary visual cortex.

    Science.gov (United States)

    Griffeth, Valerie E M; Simon, Aaron B; Buxton, Richard B

    2015-01-01

    Quantitative functional MRI (fMRI) experiments to measure blood flow and oxygen metabolism coupling in the brain typically rely on simple repetitive stimuli. Here we compared such stimuli with a more naturalistic stimulus. Previous work on the primary visual cortex showed that direct attentional modulation evokes a blood flow (CBF) response with a relatively large oxygen metabolism (CMRO2) response in comparison to an unattended stimulus, which evokes a much smaller metabolic response relative to the flow response. We hypothesized that a similar effect would be associated with a more engaging stimulus, and tested this by measuring the primary human visual cortex response to two contrast levels of a radial flickering checkerboard in comparison to the response to free viewing of brief movie clips. We did not find a significant difference in the blood flow-metabolism coupling (n=%ΔCBF/%ΔCMRO2) between the movie stimulus and the flickering checkerboards employing two different analysis methods: a standard analysis using the Davis model and a new analysis using a heuristic model dependent only on measured quantities. This finding suggests that in the primary visual cortex a naturalistic stimulus (in comparison to a simple repetitive stimulus) is either not sufficient to provoke a change in flow-metabolism coupling by attentional modulation as hypothesized, that the experimental design disrupted the cognitive processes underlying the response to a more natural stimulus, or that the technique used is not sensitive enough to detect a small difference. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Regional implications of heat flow of the Snake River Plain, Northwestern United States

    Science.gov (United States)

    Blackwell, D. D.

    1989-08-01

    The Snake River Plain is a major topographic feature of the Northwestern United States. It marks the track of an upper mantle and crustal melting event that propagated across the area from southwest to northeast at a velocity of about 3.5 cm/yr. The melting event has the same energetics as a large oceanic hotspot or plume and so the area is the continental analog of an oceanic hotspot track such as the Hawaiian Island-Emperor Seamount chain. Thus, the unique features of the area reflect the response of a continental lithosphere to a very energetic hotspot. The crust is extensively modified by basalt magma emplacement into the crust and by the resulting massive rhyolite volcanism from melted crustal material, presently occurring at Yellowstone National Park. The volcanism is associated with little crustal extension. Heat flow values are high along the margins of the Eastern and Western Snake River Plains and there is abundant evidence for low-grade geothermal resources associated with regional groundwater systems. The regional heat flow pattern in the Western Snake River Plains reflects the influence of crustal-scale thermal refraction associated with the large sedimentary basin that has formed there. Heat flow values in shallow holes in the Eastern Snake River Plains are low due to the Snake River Plains aquifer, an extensive basalt aquifer where water flow rates approach 1 km/yr. Below the aquifer, conductive heat flow values are about 100 mW m -2. Deep holes in the region suggest a systematic eastward increase in heat flow in the Snake River Plains from about 75-90 mW m -2 to 90-110 mW m -2. Temperatures in the upper crust do not behave similarly because the thermal conductivity of the Plio-Pleistocene sedimentary rocks in the west is lower than that in the volcanic rocks characteristic of the Eastern Snake River Plains. Extremely high heat loss values (averaging 2500 mW m -2) and upper crustal temperatures are characteristic of the Yellowstone caldera.

  8. The Use of Energy in Malaysia: Tracing Energy Flows from Primary Source to End Use

    Directory of Open Access Journals (Sweden)

    Chinhao Chong

    2015-04-01

    Full Text Available Malaysia is a rapidly developing country in Southeast Asia that aims to achieve high-income country status by 2020; its economic growth is highly dependent on its abundant energy resources, especially natural gas and crude oil. In this paper, a complete picture of Malaysia’s energy use from primary source to end use is presented by mapping a Sankey diagram of Malaysia’s energy flows, together with ongoing trends analysis of the main factors influencing the energy flows. The results indicate that Malaysia’s energy use depends heavily on fossil fuels, including oil, gas and coal. In the past 30 years, Malaysia has successfully diversified its energy structure by introducing more natural gas and coal into its power generation. To sustainably feed the rapidly growing energy demand in end-use sectors with the challenge of global climate change, Malaysia must pay more attention to the development of renewable energy, green technology and energy conservation in the future.

  9. A Systematic Review of Outcomes and Complications of Primary Fingertip Reconstruction Using Reverse-Flow Homodigital Island Flaps.

    Science.gov (United States)

    Regmi, Subhash; Gu, Jia-xiang; Zhang, Nai-chen; Liu, Hong-jun

    2016-04-01

    Fingertip reconstruction using reverse-flow homodigital island flaps has been very popular over the years. However, the outcomes of reconstruction have not been clearly understood. In these circumstances, a systematic review of available literature is warranted. To assess the outcomes and complications of fingertip reconstruction using reverse-flow homodigital island flaps. To justify the usage of reverse-flow homodigital island flaps for fingertip reconstruction. A PubMed [MEDLINE] electronic database was searched (1985 to 15 April 2015). Retrospective case series that met the following criteria were included: (1) Study reported primary data; (2) Study included at least five cases of fingertip defects treated using reverse-flow homodigital island flaps; (3) Study reported outcomes and complications of fingertip reconstruction, either primary or delayed, using reverse-flow homodigital island flaps; (4) The study presented at least one of the following functional outcomes: Static two-point discrimination, return-to-work time, range of motion of distal interphalangeal joints; (5) The study presented at least one complication. Two review authors independently assessed search results, and two other review authors analyzed the data and resolved disagreements. The following endpoints were analyzed: survival rate of the flap, sensibility, and functional outcomes and complications. Eight studies were included in this review. The included studies were published between 1995 and 2014, and a total of 207 patients with 230 fingertip defects were reported. The overall survival rate of the flap was 98 % (including partial survival). The mean static two-point discrimination (2PD) was 7.2 mm. The average range of motion of the DIP joint was 63°. The average return-to-work time was 7 weeks after injury. On average, 2 % of the patient had complete flap necrosis, 5 % had partial flap necrosis, 4 % developed venous congestion, 4 % developed flexion contracture, and 12 % experienced

  10. Cold flow model study of an oxyfuel combustion pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Guio-Perez, D.C.; Tondl, G.; Hoeltl, W.; Proell, T.; Hofbauer, H. [Vienna University of Technology, Institute of Chemical Engineering, Vienna (Austria)

    2011-12-15

    The fluid-dynamic behavior of a circulating fluidized bed pilot plant for oxyfuel combustion was studied in a cold flow model, down-scaled using Glicksman's criteria. Pressures along the unit and the global circulation rate were used for characterization. The analysis of five operating parameters and their influence on the system was carried out; namely, total solids inventory and the air velocity of primary, secondary, loop seal and support fluidizations. The cold flow model study shows that the reactor design allows stable operation at a wide range of fluidization rates, with results that agree well with previous observations described in the literature. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. CFD analysis for the hydrogen transport in the primary contention of a BWR using the codes OpenFOAM and Gas-Flow; Analisis CFD para el transporte de hidrogeno en la contencion primaria de un reactor BWR usando los codigos OpenFOAM y GasFlow

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez P, D. A.

    2014-07-01

    using a limited number of semi-empirical data, and instead, mathematical relationships are used taking into account the various physical phenomena as well the interactions that occur among them, such as heat transfer between the fluid and the solid walls condensation of water vapor on the walls, the turbulent effects in areas of restricted passage, etc. Taking into account these advantages, this study presents a qualitative and quantitative comparison between the CFD codes OpenFOAM and Gas-Flow related to the transport phenomena of Hydrogen and other gases in the primary containment of a BWR reactor. Gas-Flow is a code of commercial license that is well validated, developed in Germany to analyze the transport of gases in nuclear reactor containments. On the other hand, OpenFOAM is an open source CFD code offering several solvers for different phenomena assessments, in this work, the reacting Foam solver is used because it has a strong similarity to the intended application of Hydrogen transport. In this thesis the results obtained using the reacting Foam solver of OpenFOAM for the calculation of transport of Hydrogen are compared with the results of the Gas-Flow code in order to assess if it is feasible to use the open source code OpenFOAM in the case of Hydrogen transport in primary containment of a BWR reactor. Some differences in the qualitative and quantitative results from both codes were found, the differences (with a maximum error rate of 4%) in the quantitative results were found are small and are considered more than acceptable for this type of analysis, moreover, these differences are mainly attributed to the transport models used, mainly because OpenFOAM uses a homogeneous mixture model and Gas-Flow a heterogeneous one. Implementing appropriate solvers in codes like OpenFOAM has the goal to develop own tools that are applicable to the transport of Hydrogen in the primary containment of a BWR reactor and thus, to gain some independence while not relying on

  12. Large-eddy simulation of cavitating nozzle flow and primary jet break-up

    Energy Technology Data Exchange (ETDEWEB)

    Örley, F., E-mail: felix.oerley@aer.mw.tum.de; Trummler, T.; Mihatsch, M. S.; Schmidt, S. J.; Adams, N. A. [Institute of Aerodynamics and Fluid Mechanics, Technische Universität München, Boltzmannstr. 15, 85748 Garching bei München (Germany); Hickel, S. [Institute of Aerodynamics and Fluid Mechanics, Technische Universität München, Boltzmannstr. 15, 85748 Garching bei München (Germany); Chair of Computational Aerodynamics, Faculty of Aerospace Engineering, TU Delft, Kluyverweg 1, 2629 HS Delft (Netherlands)

    2015-08-15

    We employ a barotropic two-phase/two-fluid model to study the primary break-up of cavitating liquid jets emanating from a rectangular nozzle, which resembles a high aspect-ratio slot flow. All components (i.e., gas, liquid, and vapor) are represented by a homogeneous mixture approach. The cavitating fluid model is based on a thermodynamic-equilibrium assumption. Compressibility of all phases enables full resolution of collapse-induced pressure wave dynamics. The thermodynamic model is embedded into an implicit large-eddy simulation (LES) environment. The considered configuration follows the general setup of a reference experiment and is a generic reproduction of a scaled-up fuel injector or control valve as found in an automotive engine. Due to the experimental conditions, it operates, however, at significantly lower pressures. LES results are compared to the experimental reference for validation. Three different operating points are studied, which differ in terms of the development of cavitation regions and the jet break-up characteristics. Observed differences between experimental and numerical data in some of the investigated cases can be caused by uncertainties in meeting nominal parameters by the experiment. The investigation reveals that three main mechanisms promote primary jet break-up: collapse-induced turbulent fluctuations near the outlet, entrainment of free gas into the nozzle, and collapse events inside the jet near the liquid-gas interface.

  13. Channel water balance and exchange with subsurface flow along a mountain headwater stream in Montana, United States

    Science.gov (United States)

    R.A. Payn; M.N. Gooseff; B.L. McGlynn; K.E. Bencala; S.M. Wondzell

    2009-01-01

    Channel water balances of contiguous reaches along streams represent a poorly understood scale of stream-subsurface interaction. We measured reach water balances along a headwater stream in Montana, United States, during summer base flow recessions. Reach water balances were estimated from series of tracer tests in 13 consecutive reaches delineated evenly along a 2.6-...

  14. Power flow control and damping enhancement of a large wind farm using a superconducting magnetic energy storage unit

    DEFF Research Database (Denmark)

    Chen, S. S.; Wang, L.; Lee, W. J.

    2009-01-01

    A novel scheme using a superconducting magnetic energy storage (SMES) unit to perform both power flow control and damping enhancement of a large wind farm (WF) feeding to a utility grid is presented. The studied WF consisting of forty 2 MW wind induction generators (IGs) is simulated...

  15. Primary immunodeficiency investigation in patients during and after hospitalization in a pediatric Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Erica Suavinho

    2014-03-01

    Full Text Available Objective: To analyze whether the patients with severe infections, admitted in the Pediatric Intensive Care Unit of the Hospital de Clínicas of the Universidade Federal de Uberlândia, underwent the active screening for primary immunodeficiencies (PID. Methods: Retrospective study that assessed the data records of patients with any severe infections admitted in the Pediatric Intensive Care Unit, covering a period from January 2011 to January 2012, in order to confirm if they performed an initial investigation for PID with blood count and immunoglobulin dosage. Results: In the studied period, 53 children were hospitalized with severe infections in the Pediatric Intensive Care Unit, and only in seven (13.2% the initial investigation of PID was performed. Among these patients, 3/7 (42.8% showed quantitative alterations in immunoglobulin G (IgG levels, 1/7 (14.3% had the diagnosis of cyclic neutropenia, and 1/7 (14.3% presented thrombocytopenia and a final diagnosis of Wiskott-Aldrich syndrome. Therefore, the PID diagnosis was confirmed in 5/7 (71.4% of the patients. Conclusions: The investigation of PID in patients with severe infections has not been routinely performed in the Pediatric Intensive Care Unit. Our findings suggest the necessity of performing PID investigation in this group of patients.

  16. A study of grout flow pattern analysis

    International Nuclear Information System (INIS)

    Lee, S. Y.; Hyun, S.

    2013-01-01

    A new disposal unit, designated as Salt Disposal Unit no. 6 (SDU6), is being designed for support of site accelerated closure goals and salt nuclear waste projections identified in the new Liquid Waste System plan. The unit is cylindrical disposal vault of 380 ft diameter and 43 ft in height, and it has about 30 million gallons of capacity. Primary objective was to develop the computational model and to perform the evaluations for the flow patterns of grout material in SDU6 as function of elevation of grout discharge port, and slurry rheology. A Bingham plastic model was basically used to represent the grout flow behavior. A two-phase modeling approach was taken to achieve the objective. This approach assumes that the air-grout interface determines the shape of the accumulation mound. The results of this study were used to develop the design guidelines for the discharge ports of the Saltstone feed materials in the SDU6 facility. The focusing areas of the modeling study are to estimate the domain size of the grout materials radially spread on the facility floor under the baseline modeling conditions, to perform the sensitivity analysis with respect to the baseline design and operating conditions such as elevation of discharge port, discharge pipe diameter, and grout properties, and to determine the changes in grout density as it is related to grout drop height. An axi-symmetric two-phase modeling method was used for computational efficiency. Based on the nominal design and operating conditions, a transient computational approach was taken to compute flow fields mainly driven by pumping inertia and natural gravity. Detailed solution methodology and analysis results are discussed here

  17. Factors associated with student learning processes in primary health care units: a questionnaire study.

    Science.gov (United States)

    Bos, Elisabeth; Alinaghizadeh, Hassan; Saarikoski, Mikko; Kaila, Päivi

    2015-01-01

    Clinical placement plays a key role in education intended to develop nursing and caregiving skills. Studies of nursing students' clinical learning experiences show that these dimensions affect learning processes: (i) supervisory relationship, (ii) pedagogical atmosphere, (iii) management leadership style, (iv) premises of nursing care on the ward, and (v) nursing teachers' roles. Few empirical studies address the probability of an association between these dimensions and factors such as student (a) motivation, (b) satisfaction with clinical placement, and (c) experiences with professional role models. The study aimed to investigate factors associated with the five dimensions in clinical learning environments within primary health care units. The Swedish version of Clinical Learning Environment, Supervision and Teacher, a validated evaluation scale, was administered to 356 graduating nursing students after four or five weeks clinical placement in primary health care units. Response rate was 84%. Multivariate analysis of variance is determined if the five dimensions are associated with factors a, b, and c above. The analysis revealed a statistically significant association with the five dimensions and two factors: students' motivation and experiences with professional role models. The satisfaction factor had a statistically significant association (effect size was high) with all dimensions; this clearly indicates that students experienced satisfaction. These questionnaire results show that a good clinical learning experience constitutes a complex whole (totality) that involves several interacting factors. Supervisory relationship and pedagogical atmosphere particularly influenced students' satisfaction and motivation. These results provide valuable decision-support material for clinical education planning, implementation, and management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Impact of Expanded North Slope of Alaska Crude Oil Production on Crude Oil Flows in the Contiguous United States

    Energy Technology Data Exchange (ETDEWEB)

    DeRosa, Sean E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Flanagan, Tatiana Paz [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    The National Transportation Fuels Model was used to simulate a hypothetical increase in North Slope of Alaska crude oil production. The results show that the magnitude of production utilized depends in part on the ability of crude oil and refined products infrastructure in the contiguous United States to absorb and adjust to the additional supply. Decisions about expanding North Slope production can use the National Transportation Fuels Model take into account the effects on crude oil flows in the contiguous United States.

  19. The ideal oxygen/nitrous oxide fresh gas flow sequence with the Anesthesia Delivery Unit machine.

    Science.gov (United States)

    Hendrickx, Jan F A; Cardinael, Sara; Carette, Rik; Lemmens, Hendrikus J M; De Wolf, Andre M

    2007-06-01

    To determine whether early reduction of oxygen and nitrous oxide fresh gas flow from 6 L/min to 0.7 L/min could be accomplished while maintaining end-expired nitrous oxide concentration > or =50% with an Anesthesia Delivery Unit anesthesia machine. Prospective, randomized clinical study. Large teaching hospital in Belgium. 53 ASA physical status I and II patients requiring general endotracheal anesthesia and controlled mechanical ventilation. Patients were randomly assigned to one of 4 groups depending on the duration of high oxygen/nitrous oxide fresh gas flow (two and 4 L/min, respectively) before lowering total fresh gas flow to 0.7 L/min (0.3 and 0.4 L/min oxygen and nitrous oxide, respectively): one, two, three, or 5 minutes (1-minute group, 2-minute group, 3-minute group, and 5-minute group), with n = 10, 12, 13, and 8, respectively. The course of the end-expired nitrous oxide concentration and bellows volume deficit at end-expiration was compared among the 4 groups during the first 30 minutes. At the end of the high-flow period the end-expired nitrous oxide concentration was 35.6 +/- 6.2%, 48.4 +/- 4.8%, 53.7 +/- 8.7%, and 57.3 +/- 1.6% in the 4 groups, respectively. Thereafter, the end-expired nitrous oxide concentration decreased to a nadir of 36.1 +/- 4.5%, 45.4 +/- 3.8%, 50.9 +/- 6.1%, and 55.4 +/- 2.8% after three, 4, 6, and 8 minutes after flows were lowered in the 1- to 5-minute groups, respectively. A decrease in bellows volume was observed in most patients, but was most pronounced in the 2-minute group. The bellows volume deficit gradually faded within 15 to 20 minutes in all 4 groups. A 3-minute high-flow period (oxygen and nitrous oxide fresh gas flow of 2 and 4 L/min, respectively) suffices to attain and maintain end-expired nitrous oxide concentration > or =50% and ensures an adequate bellows volume during the ensuing low-flow period.

  20. The relationship between the cerebral blood flow, oxygen consumption and glucose metabolism in primary degenerative dementia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Ichimiya, Atsushi; Sasaki, Masayuki; Akashi, Yuko; Yoshida, Tsuyoshi; Fukumura, Toshimitsu; Masada, Kouji [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-03-01

    The CBF, CMRO{sub 2} and CMRGlu were measured in patients with primary degenerative dementia including 5 patients with dementia of Alzheimer`s type and 4 patients with Pick`s disease, and then the correlation between the cerebral blood flow and energy metabolism was evaluated. The control subjects consisted of 5 age-matched normal volunteers. The CBF, CMRO{sub 2} and CMRGlu decreased in the bilateral frontal, temporal and parietal regions in the patients with Alzheimer`s dementia, while they decreased in the bilateral frontal and temporal regions in the patients with Pick`s disease. Both the CBF and CMRO{sub 2} were closely correlated with each other. However, the CMRGlu was more severely impaired than the CBF or CMRO{sub 2} in both pathological conditions. These results suggested that CMRGlu began to decrease before the reduction of the aerobic metabolism and thus measuring the CMRGlu is considered to be the most sensitive method for detecting abnormal regions in primary degenerative dementia. (author).

  1. The relationship between the cerebral blood flow, oxygen consumption and glucose metabolism in primary degenerative dementia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Ichimiya, Atsushi; Sasaki, Masayuki; Akashi, Yuko; Yoshida, Tsuyoshi; Fukumura, Toshimitsu; Masada, Kouji

    1995-01-01

    The CBF, CMRO 2 and CMRGlu were measured in patients with primary degenerative dementia including 5 patients with dementia of Alzheimer's type and 4 patients with Pick's disease, and then the correlation between the cerebral blood flow and energy metabolism was evaluated. The control subjects consisted of 5 age-matched normal volunteers. The CBF, CMRO 2 and CMRGlu decreased in the bilateral frontal, temporal and parietal regions in the patients with Alzheimer's dementia, while they decreased in the bilateral frontal and temporal regions in the patients with Pick's disease. Both the CBF and CMRO 2 were closely correlated with each other. However, the CMRGlu was more severely impaired than the CBF or CMRO 2 in both pathological conditions. These results suggested that CMRGlu began to decrease before the reduction of the aerobic metabolism and thus measuring the CMRGlu is considered to be the most sensitive method for detecting abnormal regions in primary degenerative dementia. (author)

  2. Microfabrication and Test of a Three-Dimensional Polymer Hydro-focusing Unit for Flow Cytometry Applications

    Science.gov (United States)

    Yang, Ren; Feeback, Daniel L.; Wang, Wan-Jun

    2005-01-01

    This paper details a novel three-dimensional (3D) hydro-focusing micro cell sorter for micro flow cytometry applications. The unit was microfabricated by means of SU-8 3D lithography. The 3D microstructure for coaxial sheathing was designed, microfabricated, and tested. Three-dimensional hydrofocusing capability was demonstrated with an experiment to sort labeled tanned sheep erythrocytes (red blood cells). This polymer hydro-focusing microstructure is easily microfabricated and integrated with other polymer microfluidic structures. Keywords: SU-8, three-dimensional hydro-focusing, microfluidic, microchannel, cytometer

  3. Amino Acid Molecular Units: Building Primary and Secondary Protein Structures

    Directory of Open Access Journals (Sweden)

    Aparecido R. Silva

    2008-05-01

    Full Text Available In order to guarantee the learning quality and suitable knowledge  use  about structural biology, it is fundamental to  exist, since the beginning of  students’ formation, the possibility of clear visualization of biomolecule structures. Nevertheless, the didactic books can only bring  schematic  drawings; even more elaborated figures and graphic computation  do not permit the necessary interaction.  The representation of three-dimensional molecular structures with ludic models, built with representative units, have supplied to the students and teachers a successfully experience to  visualize such structures and correlate them to the real molecules.  The design and applicability of the representative units were discussed with researchers and teachers before mould implementation.  In this stage  it  will be presented the  developed  kit  containing the  representative  plastic parts of the main amino acids.  The kit can demonstrate the interaction among the amino acids  functional groups  (represented by colors, shapes,  sizes and  the peptidic bonds between them  facilitating the assembly and visuali zation of the primary and secondary protein structure.  The models were designed for  Ca,  amino,  carboxyl groups  and  hydrogen. The  lateral chains have  well defined models that represent their geometrical shape.  The completed kit set  will be presented in this meeting (patent requested.  In the last phase of the project will be realized  an effective evaluation  of the kit  as a facilitative didactic tool of the teaching/learning process in the Structural Molecular Biology area.

  4. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  5. Phase II Groundwater Flow Model of Corrective Action Unit 98: Frenchman Flat, Nevada Test Site, Nye County, Nevada, Rev. No.: 0

    International Nuclear Information System (INIS)

    John McCord

    2006-01-01

    The Phase II Frenchman Flat groundwater flow model is a key element in the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996) corrective action strategy for the Underground Test Area (UGTA) Frenchman Flat corrective action unit (CAU). The objective of this integrated process is to provide an estimate of the vertical and horizontal extent of contaminant migration for each CAU to predict contaminant boundaries. A contaminant boundary is the model-predicted perimeter that defines the extent of radionuclide-contaminated groundwater from underground testing above background conditions exceeding the ''Safe Drinking Water Act'' (SDWA) standards. The contaminant boundary will be composed of both a perimeter boundary and a lower hydrostratigraphic unit (HSU) boundary. The computer model will predict the location of this boundary within 1,000 years and must do so at a 95 percent level of confidence. Additional results showing contaminant concentrations and the location of the contaminant boundary at selected times will also be presented. These times may include the verification period, the end of the five-year proof-of-concept period, as well as other times that are of specific interest. This report documents the development and implementation of the groundwater flow model for the Frenchman Flat CAU. Specific objectives of the Phase II Frenchman Flat flow model are to: (1) Incorporate pertinent information and lessons learned from the Phase I Frenchman Flat CAU models. (2) Develop a three-dimensional (3-D), mathematical flow model that incorporates the important physical features of the flow system and honors CAU-specific data and information. (3) Simulate the steady-state groundwater flow system to determine the direction and magnitude of groundwater fluxes based on calibration to Frenchman Flat hydrogeologic data. (4) Quantify the uncertainty in the direction and magnitude of groundwater flow due to uncertainty in parameter values and alternative component

  6. Flow Energy Piezoelectric Bimorph Nozzle Harvester

    Science.gov (United States)

    Sherrit, Stewart (Inventor); Walkemeyer, Phillip E. (Inventor); Hall, Jeffrey L. (Inventor); Lee, Hyeong Jae (Inventor); Colonius, Tim (Inventor); Tosi, Phillipe (Inventor); Kim, Namhyo (Inventor); Sun, Kai (Inventor); Corbett, Thomas Gary (Inventor); Arrazola, Alvaro Jose (Inventor)

    2016-01-01

    A flow energy harvesting device having a harvester pipe includes a flow inlet that receives flow from a primary pipe, a flow outlet that returns the flow into the primary pipe, and a flow diverter within the harvester pipe having an inlet section coupled to the flow inlet, a flow constriction section coupled to the inlet section and positioned at a midpoint of the harvester pipe and having a spline shape with a substantially reduced flow opening size at a constriction point along the spline shape, and an outlet section coupled to the constriction section. The harvester pipe may further include a piezoelectric structure extending from the inlet section through the constriction section and point such that the fluid flow past the constriction point results in oscillatory pressure amplitude inducing vibrations in the piezoelectric structure sufficient to cause a direct piezoelectric effect and to generate electrical power for harvesting.

  7. Combining Stocks and Flows of Knowledge

    DEFF Research Database (Denmark)

    Ambos, Tina C.; Nell, Phillip Christopher; Pedersen, Torben

    In the area of knowledge management and knowledge governance, previous research has mostly focused on either knowledge stocks or knowledge flows of firms or organizational units. Contrary to this work, our study is among the first to integrate these two perspectives in order to shed light...... on the complementarity effects of different types of knowledge stocks and flows in the multinational corporation (MNC). We investigate intra-functional as well as cross-functional complementarity effects from the perspective of the knowledge recipient. We test the impact of stocks on flows on the benefit that is created...... for MNC units. Based on a comprehensive sample of 324 relationships between MNC units we find that both types of complementarity create benefits for these units, but that the effects from intra-functional combinations of knowledge stocks and flows are significantly stronger than from cross...

  8. Dresden Nuclear Power Station, Unit No. 1: Primary cooling system chemical decontamination: Draft environmental statement (Docket No. 50-10)

    International Nuclear Information System (INIS)

    1980-05-01

    The staff has considered the environmental impact and economic costs of the proposed primary cooling system chemical decontamination at Dresden Nuclear Power Station, Unit 1. The staff has focused this statement on the occupational radiation exposure associated with the proposed Unit 1 decontamination program, on alternatives to chemical decontamination, and on the environmental impact of the disposal of the solid radioactive waste generated by this decontamination. The staff has concluded that the proposed decontamination will not significantly affect the quality of the human environment. Furthermore, any impacts from the decontamination program are outweighed by its benefits. 2 figs., 7 tabs

  9. ANALISIS KEJADIAN STEAM GENERATOR TUBE RUPTURE (SGTR BERDASARKAN SKENARIO MIHAMA UNIT 2

    Directory of Open Access Journals (Sweden)

    Andi Sofrany Ekariansyah

    2015-03-01

    Japanese standard PWR to be simulated using RELAP5/SCDAP/Mod3.2 thermal-hydraulic code. The purpose is to compare consequences resulted if this accident is occurred on the Japanese standard PWR. Parameter compared are break mass flow, fluctuation of primary and secondary pressure, and fluctuation of pressurizer level. The simulation result shown that the difference in the time duration from the initiation of rupture up to the leak termination, which takes place in shorter duration on the standard Japanese PWR. It is also shown that the total amount of the primary coolant leaked through the break nozzle to the secondary system that calculated is bigger than on the Mihama unit 2. The character of break mass flow, fluctuation of the primary system and level of pressurizer is slightly different in the beginning of the event, but is in similar trend in the end of event as the break flow is terminated. The simulation result also shows the necessity of operator action to manually isolate the auxiliary feedwater system in the affected steam generator, to actuate the main steam relief valves in the intact steam generator, and to actuate the auxiliary spray and power operated relief valve on pressurizer to anticipate the event as part of the emergency operating procedures. Keywords: SGTR, Mihama Unit 2,standard Japanese PWR

  10. Analysis of impact of general-purpose graphics processor units in supersonic flow modeling

    Science.gov (United States)

    Emelyanov, V. N.; Karpenko, A. G.; Kozelkov, A. S.; Teterina, I. V.; Volkov, K. N.; Yalozo, A. V.

    2017-06-01

    Computational methods are widely used in prediction of complex flowfields associated with off-normal situations in aerospace engineering. Modern graphics processing units (GPU) provide architectures and new programming models that enable to harness their large processing power and to design computational fluid dynamics (CFD) simulations at both high performance and low cost. Possibilities of the use of GPUs for the simulation of external and internal flows on unstructured meshes are discussed. The finite volume method is applied to solve three-dimensional unsteady compressible Euler and Navier-Stokes equations on unstructured meshes with high resolution numerical schemes. CUDA technology is used for programming implementation of parallel computational algorithms. Solutions of some benchmark test cases on GPUs are reported, and the results computed are compared with experimental and computational data. Approaches to optimization of the CFD code related to the use of different types of memory are considered. Speedup of solution on GPUs with respect to the solution on central processor unit (CPU) is compared. Performance measurements show that numerical schemes developed achieve 20-50 speedup on GPU hardware compared to CPU reference implementation. The results obtained provide promising perspective for designing a GPU-based software framework for applications in CFD.

  11. Techniques used by United Kingdom consultant plastic surgeons to select implant size for primary breast augmentation.

    Science.gov (United States)

    Holmes, W J M; Timmons, M J; Kauser, S

    2015-10-01

    Techniques used to estimate implant size for primary breast augmentation have evolved since the 1970s. Currently no consensus exists on the optimal method to select implant size for primary breast augmentation. In 2013 we asked United Kingdom consultant plastic surgeons who were full members of BAPRAS or BAAPS what was their technique for implant size selection for primary aesthetic breast augmentation. We also asked what was the range of implant sizes they commonly used. The answers to question one were grouped into four categories: experience, measurements, pre-operative external sizers and intra-operative sizers. The response rate was 46% (164/358). Overall, 95% (153/159) of all respondents performed some form of pre-operative assessment, the others relied on "experience" only. The most common technique for pre-operative assessment was by external sizers (74%). Measurements were used by 57% of respondents and 3% used intra-operative sizers only. A combination of measurements and sizers was used by 34% of respondents. The most common measurements were breast base (68%), breast tissue compliance (19%), breast height (15%), and chest diameter (9%). The median implant size commonly used in primary breast augmentation was 300cc. Pre-operative external sizers are the most common technique used by UK consultant plastic surgeons to select implant size for primary breast augmentation. We discuss the above findings in relation to the evolution of pre-operative planning techniques for breast augmentation. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Knowledge flow and exchange in interdisciplinary primary health care teams (PHCTs): an exploratory study

    Science.gov (United States)

    Sibbald, Shannon L.; Wathen, C. Nadine; Kothari, Anita; Day, Adam M. B.

    2013-01-01

    Objective: Improving the process of evidence-based practice in primary health care requires an understanding of information exchange among colleagues. This study explored how clinically oriented research knowledge flows through multidisciplinary primary health care teams (PHCTs) and influences clinical decisions. Methods: This was an exploratory mixed-methods study with members of six PHCTs in Ontario, Canada. Quantitative data were collected using a questionnaire and analyzed with social network analysis (SNA) using UCINet. Qualitative data were collected using semi-structured interviews and analyzed with content analysis procedures using NVivo8. Results: It was found that obtaining research knowledge was perceived to be a shared responsibility among team members, whereas its application in patient care was seen as the responsibility of the team leader, usually the senior physician. PHCT members acknowledged the need for resources for information access, synthesis, interpretation, or management. Conclusion: Information sharing in interdisciplinary teams is a complex and multifaceted process. Specific interventions need to be improved such as formalizing modes of communication, better organizing knowledge-sharing activities, and improving the active use of allied health professionals. Despite movement toward team-based models, senior physicians are often gatekeepers of uptake of new evidence and changes in practice. PMID:23646028

  13. Catalyst volumetric fraction simulation in a riser of a cold flow pilot unit with aid of transmission gamma technique

    International Nuclear Information System (INIS)

    Santos, Kamylla A.L. dos; Lima Filho, Hilario J.B. de; Benachour, Mohand; Dantas, Carlos C.; Santos, Valdemir A. dos

    2013-01-01

    Was obtained the radial profile of the catalyst volume fraction in a riser of the cold flow pilot unit of the Fluid Catalytic Cracking (FCC) unit, which was used for adjustment of the entrance conditions of the catalyst in a simulation program by Computational Fluid Dynamics (CFD). The height of the riser of the Cold Flow Pilot Unity (CFPU) utilized is 6.0m and its inner diameter is 0.097 m. A radiation-γ source of Am-241 and a NaI (Tl) detector, with shielding made of lead, have been installed on a steel backing that maintains the geometry of the source-detector-riser and allows to vary the distance from the source to the detector and the radial position in a given cross section of the riser. The data associated with the simulation of volume fraction radial profile of the catalyst were: Fluent software, version 12.0; preprocessor GAMBIT, version 2.3.16; Eulerian approach; structured mesh, cell number of 60000; turbulence model used was k-ε and kinetic theory of granular flow (KTGF) was implemented to describe the solid phase. Comparison of radial profiles simulated and experimental of the catalyst volumetric fraction in the CFPU riser allowed the identification of needs adjustments in the simulation for the input of catalyst, with consequent validation for the proposed model simulation. (author)

  14. Analysis of serial coronary artery flow patterns early after primary angioplasty: new insights into the dynamics of the microcirculation.

    Science.gov (United States)

    Sharif, Dawod; Rofe, Guy; Sharif-Rasslan, Amal; Goldhammer, Ehud; Makhoul, Nabeel; Shefer, Arie; Hassan, Amin; Rauchfleisch, Shmuel; Rosenschein, Uri

    2008-06-01

    The temporal behavior of the coronary microcirculation in acute myocardial infarction may affect outcome. Diastolic deceleration time and early systolic flow reversal derived from coronary artery blood flow velocity patterns reflect microcirculatory function. To assess left anterior descending coronary artery flow velocity patterns using Doppler transthoracic echocardiography after primary percutaneous coronary intervention, in patients with anterior AMI. Patterns of flow velocity patterns of the LAD were obtained using transthoracic echocardiography-Doppler in 31 consecutive patients who presented with anterior AMI. Measurements were done at 6 hours, 36-48 hours, and 5 days after successful PPCI. Measurements of DDT and pressure half times (Pt%), as well as observation for ESFR were performed. In the first 2 days following PPCI, the average DDT (600 +/- 340 msec) was shorter than on day 5 (807 +/- 332 msec) (P 600 msec) and vice versa. On day 5 most DDTs became longer. Pt1/2 at 6 hours was not different than at day 2 (174 +/- 96 vs. 193 +/- 99 msec, P = NS) and became longer on day 5 (235 +/- 98 msec, P = 0.012). Bidirectional patterns were also observed in the ESFR in 6 patients (19%) at baseline, in 4 (13%) at 36 hours, and in 2 (6.5%) on day 5 after PPCI. Flow velocity patterns of the LAD after PPCI in AMI are dynamic and reflect unpredictable changes in microcirculation.

  15. Post-fire debris flow prediction in Western United States: Advancements based on a nonparametric statistical technique

    Science.gov (United States)

    Nikolopoulos, E. I.; Destro, E.; Bhuiyan, M. A. E.; Borga, M., Sr.; Anagnostou, E. N.

    2017-12-01

    Fire disasters affect modern societies at global scale inducing significant economic losses and human casualties. In addition to their direct impacts they have various adverse effects on hydrologic and geomorphologic processes of a region due to the tremendous alteration of the landscape characteristics (vegetation, soil properties etc). As a consequence, wildfires often initiate a cascade of hazards such as flash floods and debris flows that usually follow the occurrence of a wildfire thus magnifying the overall impact in a region. Post-fire debris flows (PFDF) is one such type of hazards frequently occurring in Western United States where wildfires are a common natural disaster. Prediction of PDFD is therefore of high importance in this region and over the last years a number of efforts from United States Geological Survey (USGS) and National Weather Service (NWS) have been focused on the development of early warning systems that will help mitigate PFDF risk. This work proposes a prediction framework that is based on a nonparametric statistical technique (random forests) that allows predicting the occurrence of PFDF at regional scale with a higher degree of accuracy than the commonly used approaches that are based on power-law thresholds and logistic regression procedures. The work presented is based on a recently released database from USGS that reports a total of 1500 storms that triggered and did not trigger PFDF in a number of fire affected catchments in Western United States. The database includes information on storm characteristics (duration, accumulation, max intensity etc) and other auxiliary information of land surface properties (soil erodibility index, local slope etc). Results show that the proposed model is able to achieve a satisfactory prediction accuracy (threat score > 0.6) superior of previously published prediction frameworks highlighting the potential of nonparametric statistical techniques for development of PFDF prediction systems.

  16. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  17. Effect of mobile unidirectional air flow unit on microbial contamination of air in standard urologic procedures.

    Science.gov (United States)

    Ferretti, Stefania; Pasquarella, Cesira; Fornia, Samanta; Saccani, Elisa; Signorelli, Carlo; Vitali, Pietro; Sansebastiano, Giuliano Ezio

    2009-12-01

    Infection is one of the most feared complications of surgery. New instrumentation is being developed to reduce deposition of bacteria. We investigated 45 major surgical procedures (21 radical nephrectomies [RN] and 24 radical retropubic prostatectomies [RRP]) in our urology department during 2007. In about one-half of the interventions, an ultraclean air flow mobile (UAF) unit was used. Bacterial sedimentation was evaluated by nitrocellulose membranes placed on the instrument tray and by settle plates positioned at four points in the operating room. In 27 operations, an additional membrane was located near the incision. Bacterial counts on the nitrocellulose membranes during RN were 230 colony-forming units (cfu)/m(2)/h with the UAF unit and 2,254 cfu/m(2)/h without the unit (p = 0.001). During RRP, the values were 288 cfu/m(2)/h and 3,126 cfu/m(2)/h respectively (p = 0.001). The membrane placed near the incision during RN showed a microbial count of 1,235 cfu/m(2)/h with the UAF unit and 5,093 cfu/m(2)/h without the unit (p = 0.002); during RRP, the values were 1,845 cfu/m(2)/h and 3,790 cfu/m(2)/h, respectively (difference not significant). Bacterial contamination detected by settle plates during RN showed a mean value of 2,273 cfu/m(2)/h when the UAF unit was used and 2,054 cfu/m(2)/h without the unit; during RRP, the values were 2,332 cfu/m(2)/h and 2,629 cfu/m(2)/h with and without the UAF unit, respectively (NS). No statistically significant differences were detected in the clinical data registered in patients operated on under standard conditions and while the UAF unit was functioning. The UAF appears able to reduce microbial contamination at the operating table, reaching a bacterial number obtained in ultraclean operating theatres.

  18. Amphiphilic mediated sample preparation for micro-flow cytometry

    Science.gov (United States)

    Clague, David S [Livermore, CA; Wheeler, Elizabeth K [Livermore, CA; Lee, Abraham P [Irvine, CA

    2009-03-17

    A flow cytometer includes a flow cell for detecting the sample, an oil phase in the flow cell, a water phase in the flow cell, an oil-water interface between the oil phase and the water phase, a detector for detecting the sample at the oil-water interface, and a hydrophobic unit operatively connected to the sample. The hydrophobic unit is attached to the sample. The sample and the hydrophobic unit are placed in an oil and water combination. The sample is detected at the interface between the oil phase and the water phase.

  19. Modeling sediment concentration of rill flow

    Science.gov (United States)

    Yang, Daming; Gao, Peiling; Zhao, Yadong; Zhang, Yuhang; Liu, Xiaoyuan; Zhang, Qingwen

    2018-06-01

    Accurate estimation of sediment concentration is essential to establish physically-based erosion models. The objectives of this study were to evaluate the effects of flow discharge (Q), slope gradient (S), flow velocity (V), shear stress (τ), stream power (ω) and unit stream power (U) on sediment concentration. Laboratory experiments were conducted using a 10 × 0.1 m rill flume under four flow discharges (2, 4, 8 and 16 L min-1), and five slope gradients (5°, 10°, 15°, 20° and 25°). The results showed that the measured sediment concentration varied from 87.08 to 620.80 kg m-3 with a mean value of 343.13 kg m-3. Sediment concentration increased as a power function with flow discharge and slope gradient, with R2 = 0.975 and NSE = 0.945. The sediment concentration was more sensitive to slope gradient than to flow discharge. The sediment concentration was well predicted by unit stream power (R2 = 0.937, NSE = 0.865), whereas less satisfactorily by flow velocity (R2 = 0.470, NSE = 0.539) and stream power (R2 = 0.773, NSE = 0.732). In addition, using the equations to simulate the measured sediment concentration of other studies, the result further indicated that slope gradient, flow discharge and unit stream power were good predictors of sediment concentration. In general, slope gradient, flow discharge and unit stream power seem to be the preferred predictors for estimating sediment concentration.

  20. Determination of primary flow by correlation of temperatures of the coolant; Medicion de caudal primario por correlacion de temperaturas del refrigerante

    Energy Technology Data Exchange (ETDEWEB)

    Villanueva, Jose [Comision Nacional de Energia Atomica, Ezeiza (Argentina). Centro Atomico Ezeiza

    2003-07-01

    Correlation techniques are often used to assess primary coolant flow in nuclear reactors. Observable fluctuations of some physical or chemical coolant properties are suitable for this purpose. This work describes a development carried out at the National Atomic Energy Commission of Argentina (CNEA) to apply this technique to correlate temperature fluctuations. A laboratory test was performed. Two thermocouples were installed on a hydraulic loop. A stationary flow of water circulated by the mentioned loop, where a mechanical turbine type flowmeter was installed. Transit times given by the correlation flowmeter, for different flow values measured with the mechanical flowmeter, were registered and a calibration between them was done. A very good linear behavior was obtained in all the measured range. It was necessary to increase the fluctuation level by adding water at different temperatures at the measuring system input. (author)

  1. Experience in vibro-acoustic control of primary coolant circuit aggregates

    International Nuclear Information System (INIS)

    Sedov, V.K.; Adamenkov, K.A.

    1977-01-01

    Fundamental principles and possibilities of vibro-acoustic control of the primary coolant circuit in nuclear power plants for detecting failures (slack parts, penetration of foreign bodies, crack formation, etc.) are presented. As a result of pressure and flow rate fluctuations such failures give rise to characteristic changes in apmplitude and frequency of vibration and technological noise from the different aggregates with respect to a 'calibration' spectrum taken in the intact state. Nature and location of the failures may be determined by statistical analysis of the signals recorded from pressure and acceleration gauges. Certain parts of the primary circuit are controlled, especially the main circulation pumps. Additionally, neutron noise has been measured in order to control the core insertions. The method is illustrated by means of measurements performed in the units 1 to 4 of the Novovoronezh nuclear power plant during start-up operation and continuous operation. (author)

  2. Experience in vibro-acoustic control of primary coolant circuit aggregates

    Energy Technology Data Exchange (ETDEWEB)

    Sedov, V K; Adamenkov, K A [Nuclear power plant Novo-Voronesh (USSR)

    1977-10-01

    Fundamental principles and possibilities of vibro-acoustic control of the primary coolant circuit in nuclear power plants for detecting failures (slack parts, penetration of foreign bodies, crack formation, etc.) are presented. As a result of pressure and flow rate fluctuations such failures give rise to characteristic changes in apmplitude and frequency of vibration and technological noise from the different aggregates with respect to a 'calibration' spectrum taken in the intact state. Nature and location of the failures may be determined by statistical analysis of the signals recorded from pressure and acceleration gauges. Certain parts of the primary circuit are controlled, especially the main circulation pumps. Additionally, neutron noise has been measured in order to control the core insertions. The method is illustrated by means of measurements performed in the units 1 to 4 of the Novovoronezh nuclear power plant during start-up operation and continuous operation.

  3. Geothermal rice drying unit in Kotchany, Macedonia

    International Nuclear Information System (INIS)

    Popovski, K.; Dimitrov, K.; Andrejevski, B.; Popovska, S.

    1992-01-01

    A geothermal field in Kotchany (Macedonia) has very advantageous characteristics for direct application purposes. Low content of minerals, moderate temperature (78C) and substantial available geothermal water flow (up to 300 1/s) enabled the establishment of a district heating scheme comprising mainly agricultural and industrial uses. A rice drying unit of 10 t/h capacity was installed 8 years ago, using the geothermal water as the primary heat source. A temperature drop of 75/50C enables the adaptation of conventional drying technology, already proven in practice in the surrounding rice growing region. Water to air heat exchanger and all necessary equipment and materials are of local production, made of copper and carbon steel. The use of such drying units is strongly recommended for the concrete district heating scheme because it offers a very simple geothermal application and enables improvement in the annual heating load factor without high investments in geothermal water distribution lines

  4. Primary care units in Emilia-Romagna, Italy: an assessment of organizational culture.

    Science.gov (United States)

    Pracilio, Valerie P; Keith, Scott W; McAna, John; Rossi, Giuseppina; Brianti, Ettore; Fabi, Massimo; Maio, Vittorio

    2014-01-01

    This study investigates the organizational culture and associated characteristics of the newly established primary care units (PCUs)-collaborative teams of general practitioners (GPs) who provide patients with integrated health care services-in the Emilia-Romagna Region (RER), Italy. A survey instrument covering 6 cultural dimensions was administered to all 301 GPs in 21 PCUs in the Local Health Authority (LHA) of Parma, RER; the response rate was 79.1%. Management style, organizational trust, and collegiality proved to be more important aspects of PCU organizational culture than information sharing, quality, and cohesiveness. Cultural dimension scores were positively associated with certain characteristics of the PCUs including larger PCU size and greater proportion of older GPs. The presence of female GPs in the PCUs had a negative impact on collegiality, organizational trust, and quality. Feedback collected through this assessment will be useful to the RER and LHAs for evaluating and guiding improvements in the PCUs. © 2013 by the American College of Medical Quality.

  5. Operational integration in primary health care: patient encounters and workflows.

    Science.gov (United States)

    Sifaki-Pistolla, Dimitra; Chatzea, Vasiliki-Eirini; Markaki, Adelais; Kritikos, Kyriakos; Petelos, Elena; Lionis, Christos

    2017-11-29

    Despite several countrywide attempts to strengthen and standardise the primary healthcare (PHC) system, Greece is still lacking a sustainable, policy-based model of integrated services. The aim of our study was to identify operational integration levels through existing patient care pathways and to recommend an alternative PHC model for optimum integration. The study was part of a large state-funded project, which included 22 randomly selected PHC units located across two health regions of Greece. Dimensions of operational integration in PHC were selected based on the work of Kringos and colleagues. A five-point Likert-type scale, coupled with an algorithm, was used to capture and transform theoretical framework features into measurable attributes. PHC services were grouped under the main categories of chronic care, urgent/acute care, preventive care, and home care. A web-based platform was used to assess patient pathways, evaluate integration levels and propose improvement actions. Analysis relied on a comparison of actual pathways versus optimal, the latter ones having been identified through literature review. Overall integration varied among units. The majority (57%) of units corresponded to a basic level. Integration by type of PHC service ranged as follows: basic (86%) or poor (14%) for chronic care units, poor (78%) or basic (22%) for urgent/acute care units, basic (50%) for preventive care units, and partial or basic (50%) for home care units. The actual pathways across all four categories of PHC services differed from those captured in the optimum integration model. Certain similarities were observed in the operational flows between chronic care management and urgent/acute care management. Such similarities were present at the highest level of abstraction, but also in common steps along the operational flows. Existing patient care pathways were mapped and analysed, and recommendations for an optimum integration PHC model were made. The developed web

  6. Flow units from integrated WFT and NMR data

    Energy Technology Data Exchange (ETDEWEB)

    Kasap, E.; Altunbay, M.; Georgi, D.

    1997-08-01

    Reliable and continuous permeability profiles are vital as both hard and soft data required for delineating reservoir architecture. They can improve the vertical resolution of seismic data, well-to-well stratigraphic correlations, and kriging between the well locations. In conditional simulations, permeability profiles are imposed as the conditioning data. Variograms, covariance functions and other geostatistical indicators are more reliable when based on good quality permeability data. Nuclear Magnetic Resonance (NMR) logging and Wireline Formation Tests (WFT) separately generate a wealth of information, and their synthesis extends the value of this information further by providing continuous and accurate permeability profiles without increasing the cost. NMR and WFT data present a unique combination because WFTs provide discrete, in situ permeability based on fluid-flow, whilst NMR responds to the fluids in the pore space and yields effective porosity, pore-size distribution, bound and moveable fluid saturations, and permeability. The NMR permeability is derived from the T{sub 2}-distribution data. Several equations have been proposed to transform T{sub 2} data to permeability. Regardless of the transform model used, the NMR-derived permeabilities depend on interpretation parameters that may be rock specific. The objective of this study is to integrate WFT permeabilities with NMR-derived, T{sub 2} distribution-based permeabilities and thereby arrive at core quality, continuously measured permeability profiles. We outlined the procedures to integrate NMR and WFT data and applied the procedure to a field case. Finally, this study advocates the use of hydraulic unit concepts to extend the WFT-NMR derived, core quality permeabilities to uncored intervals or uncored wells.

  7. Phase II Groundwater Flow Model of Corrective Action Unit 98: Frenchman Flat, Nevada Test Site, Nye County, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    John McCord

    2006-05-01

    The Phase II Frenchman Flat groundwater flow model is a key element in the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996) corrective action strategy for the Underground Test Area (UGTA) Frenchman Flat corrective action unit (CAU). The objective of this integrated process is to provide an estimate of the vertical and horizontal extent of contaminant migration for each CAU to predict contaminant boundaries. A contaminant boundary is the model-predicted perimeter that defines the extent of radionuclide-contaminated groundwater from underground testing above background conditions exceeding the ''Safe Drinking Water Act'' (SDWA) standards. The contaminant boundary will be composed of both a perimeter boundary and a lower hydrostratigraphic unit (HSU) boundary. The computer model will predict the location of this boundary within 1,000 years and must do so at a 95 percent level of confidence. Additional results showing contaminant concentrations and the location of the contaminant boundary at selected times will also be presented. These times may include the verification period, the end of the five-year proof-of-concept period, as well as other times that are of specific interest. This report documents the development and implementation of the groundwater flow model for the Frenchman Flat CAU. Specific objectives of the Phase II Frenchman Flat flow model are to: (1) Incorporate pertinent information and lessons learned from the Phase I Frenchman Flat CAU models. (2) Develop a three-dimensional (3-D), mathematical flow model that incorporates the important physical features of the flow system and honors CAU-specific data and information. (3) Simulate the steady-state groundwater flow system to determine the direction and magnitude of groundwater fluxes based on calibration to Frenchman Flat hydrogeologic data. (4) Quantify the uncertainty in the direction and magnitude of groundwater flow due to uncertainty in

  8. Geophysical data collected during the 2014 minute 319 pulse flow on the Colorado River below Morelos Dam, United States and Mexico

    Science.gov (United States)

    Kennedy, Jeffrey R.; Callegary, James B.; Macy, Jamie P.; Reyes-Lopez, Jaime; Pérez-Flores, Marco

    2017-05-09

    Geophysical methods were used to monitor infiltration during a water release, referred to as a “pulse flow,” in the Colorado River delta in March and April 2014. The pulse flow was enabled by Minute 319 of the 1944 United States–Mexico Treaty concerning water of the Colorado River. Fieldwork was carried out by the U.S. Geological Survey and the Centro de Investigación Científica y de Educación Superior de Ensenada as part of a binational effort to monitor the hydrologic effects of the pulse flow along the limitrophe (border) reach of the Colorado River and into Mexico. Repeat microgravity measurements were made at 25 locations in the southern limitrophe reach to quantify aquifer storage change during the pulse flow. Observed increases in storage along the river were greater with distance to the south, and the amount of storage change decreased away from the river channel. Gravity data at four monitoring well sites indicate specific yield equal to 0.32±0.05. Electromagnetic induction methods were used at 12 transects in the limitrophe reach of the river along the United States– Mexico border, and farther south into Mexico. These data, which are sensitive to variation in soil texture and water content, suggest relatively homogeneous conditions. Repeat direct-current resistivity measurements were collected at two locations to monitor groundwater elevation. Results indicate rapid groundwater-level rise during the pulse flow in the limitrophe reach and smaller variation at a more southern transect. Together, these data are useful for hydrogeologic characterization and hydrologic model development. Electronic data files are provided in the accompanying data release (Kennedy and others, 2016a).

  9. Risk factors associated with non-alcoholic fatty liver disease in subjects from primary care units. A case-control study

    Directory of Open Access Journals (Sweden)

    Bernad Jesús

    2008-10-01

    Full Text Available Abstract Background Non alcoholic fatty liver disease (NAFL consists in the accumulation of fat vacuoles in the cytoplasm of hepatocytes. Many etiologic factors are associated with NAFL, such as, the metabolic syndrome factors, medications, bariatric surgery, nutritional disorders. However, very little information is available on the clinical relevance of this disorder as a health problem in the general population. Methods and design The aim of the study is establish the risk factors most frequently associated with NAFL in a general adult population assigned to the primary care units and to investigate the relationship between each component of the metabolic syndrome and the risk of having a NAFL. A population based case-control, observational and multicenter study will be carried out in 18 primary care units from the "Area de Gestión del Barcelonés Nord y Maresme" (Barcelona attending a population of 360,000 inhabitants and will include 326 cases and 370 controls. Cases are defined as all subjects fulfilling the inclusion criteria and with evidence of fatty liver in an abdominal ultrasonography performed for any reason. One control will be randomly selected for each case from the population, matched for age, gender and primary care center. Controls with fatty liver or other liver diseases will be excluded. All cases and controls will be asked about previous hepatic diseases, consumption of alcohol, smoking and drugs, and a physical examination, biochemical analyses including liver function tests, the different components of the metabolic syndrome and the HAIR score will also be performed. Paired controls will also undergo an abdominal ultrasonography. Discussion This study will attempt to determine the factors most frequently associated with the presence of NAFL investigate the relationship between the metabolic syndrome and the risk of fatty liver and study the influence of the different primary care professionals in avoiding the evolution

  10. Assertion based verification methodology for HDL designs of primary sodium pump speed and eddy current flow measurement systems of PFBR

    International Nuclear Information System (INIS)

    Misra, M.K.; Menon, Saritha P.; Thirugnana Murthy, D.

    2013-01-01

    With the growing complexity and size of digital designs, functional verification has become a huge challenge. The validation and testing process accounts for a significant percentage of the overall development effort and cost for electronic systems. Many studies have shown that up to 70% of the design development time and resources are spent on functional verification. Functional errors manifest themselves very early in the design flow, and unless they are detected upfront, they can result in severe consequences - both financially and from a safety viewpoint. This paper covers the various types of verification methodologies and focuses on Assertion Based Verification Methodology for HDL designs, taking as case studies, the Primary Sodium Pump Speed and Eddy Current Flow Measurement Systems of PFBR. (author)

  11. The primary circuit materials properties results analysis performed on archive material used in NPP V-1 and Kola NPP Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Kupca, L.; Beno, P. [Nuclear Power Plants Research Institute Inc., Trnava (Slovakia)

    1997-04-01

    A very brief summary is provided of a primary circuit piping material properties analysis. The analysis was performed for the Bohunice V-1 reactor and the Kola-1 and -2 reactors. Assessment was performed on Bohunice V-1 archive materials and primary piping material cut from the Kola units after 100,000 hours of operation. Main research program tasks included analysis of mechanical properties, corrosion stability, and microstructural properties. Analysis results are not provided.

  12. Treatability test plan for the 200-ZP-1 operable unit

    International Nuclear Information System (INIS)

    1994-07-01

    This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-ZP-1 Operable Unit. The approach discussed in this treatability test plan is to conduct a pilot-scale pump and treat test for the contaminant plume associated with the 200-ZP-1 Operable Unit. The primary contaminants of concern are carbon tetrachloride, chloroform, and trichloroethylene (TCE). The pilot-scale treatability testing has as its primary purpose to assess the performance of aboveground treatment systems with respect to the ability to remove the primary contaminants present in groundwater withdrawn from the contaminant plume. The overall scope of this test plan includes: description of the pump and treat system to be tested, as well as the test performance objectives and data quality objectives (DQOs) that will be used to evaluate the effectiveness of the pilot-scale treatment system; discussion of the treatment technology to be tested and supporting development activities, including process flow and conceptual design descriptions and equipment, fabrication, utility, and system startup needs; description of pilot-scale treatment system performance, operating procedures, and operational controls, as well as anticipated monitoring activities, analytes, parameters, analytical procedures, and quality assurance protocols; summaries of other related treatability testing elements, including personnel and environmental health and safety controls, process and secondary waste management and disposition, schedule, and program organization

  13. Environmental stressors afflicting tailwater stream reaches across the United States

    Science.gov (United States)

    Miranda, Leandro E.; Krogman, R. M.

    2014-01-01

    The tailwater is the reach of a stream immediately below an impoundment that is hydrologically, physicochemically and biologically altered by the presence and operation of a dam. The overall goal of this study was to gain a nationwide awareness of the issues afflicting tailwater reaches in the United States. Specific objectives included the following: (i) estimate the percentage of reservoirs that support tailwater reaches with environmental conditions suitable for fish assemblages throughout the year, (ii) identify and quantify major sources of environmental stress in those tailwaters that do support fish assemblages and (iii) identify environmental features of tailwater reaches that determine prevalence of key fish taxa. Data were collected through an online survey of fishery managers. Relative to objective 1, 42% of the 1306 reservoirs included in this study had tailwater reaches with sufficient flow to support a fish assemblage throughout the year. The surface area of the reservoir and catchment most strongly delineated reservoirs maintaining tailwater reaches with or without sufficient flow to support a fish assemblage throughout the year. Relative to objective 2, major sources of environmental stress generally reflected flow variables, followed by water quality variables. Relative to objective 3, zoogeography was the primary factor discriminating fish taxa in tailwaters, followed by a wide range of flow and water quality variables. Results for objectives 1–3 varied greatly among nine geographic regions distributed throughout the continental United States. Our results provide a large-scale view of the effects of reservoirs on tailwater reaches and may help guide research and management needs.

  14. Catastrophic shifts in the aquatic primary production revealed by a small low-flow section of tropical downstream after dredging.

    Science.gov (United States)

    Marotta, H; Enrich-Prast, A

    2015-11-01

    Dredging is a catastrophic disturbance that directly affects key biological processes in aquatic ecosystems, especially in those small and shallow. In the tropics, metabolic responses could still be enhanced by the high temperatures and solar incidence. Here, we assessed changes in the aquatic primary production along a small section of low-flow tropical downstream (Imboassica Stream, Brazil) after dredging. Our results suggested that these ecosystems may show catastrophic shifts between net heterotrophy and autotrophy in waters based on three short-term stages following the dredging: (I) a strongly heterotrophic net primary production -NPP- coupled to an intense respiration -R- likely supported by high resuspended organic sediments and nutrients from the bottom; (II) a strongly autotrophic NPP coupled to an intense gross primary production -GPP- favored by the high nutrient levels and low solar light attenuation from suspended solids or aquatic macrophytes; and (III) a NPP near to the equilibrium coupled to low GPP and R rates following, respectively, the shading by aquatic macrophytes and high particulate sedimentation. In conclusion, changes in aquatic primary production could be an important threshold for controlling drastic shifts in the organic matter cycling and the subsequent silting up of small tropical streams after dredging events.

  15. Experimental investigations on the deposition and remobilization of aerosol particles in turbulent flows

    International Nuclear Information System (INIS)

    Barth, Thomas

    2014-01-01

    Aerosol particle deposition and resuspension experiments in turbulent flows were performed to investigate the complex particle transport phenomena and to provide a database for the development and validation of computational fluid dynamics (CFD) codes. The background motivation is related to the source term analysis of an accidental depressurization scenario of a High Temperature Reactor (HTR). During the operation of former HTR pilot plants, larger amounts of radio-contaminated graphite dust were found in the primary circuit. This dust most likely arose due to abrasion between the graphitic core components and was deposited on the inner wall surfaces of the primary circuit. In case of an accident scenario, such as a depressurization of the primary circuit, the dust may be remobilized and may escape the system boundaries. The estimation of the source term being discharged during such a scenario requires fundamental knowledge of the particle deposition, the amount of contaminants per unit mass as well as the resuspension phenomena. Nowadays, the graphite dust distribution in the primary circuit of an HTR can be calculated for stationary conditions using one-dimensional reactor system codes. However, it is rather unknown which fraction of the graphite dust inventory may be remobilized during a depressurization of the HTR primary circuit. Two small-scale experimental facilities were designed and a set of experiments was performed to investigate particle transport, deposition and resuspension in turbulent flows. The facility design concept is based on the fluid dynamic downscaling of the helium pressure boundary in the HTR primary circuit to an airflow at ambient conditions in the laboratory. The turbulent flow and the particles were recorded by high-resolution, non-invasive imaging techniques to provide a spatio-temporal insight into the particle transport processes. The different investigations of this thesis can be grouped into three categories. Firstly, the

  16. Design and Performance Evaluation of a Combined DHX unit for SFR Design Application

    International Nuclear Information System (INIS)

    Eoh, Jaehyuk; Kim, Dehee; Park, Chang-Gyu; Jeong, Ji-Young

    2015-01-01

    Based on a higher operating temperature with excellent thermal conductivity and larger thermal inertia of liquid sodium coolant, the SFR system has employed passive safety systems to ensure reliable decay heat removal (DHR) and consequential plant safety enhancement. Although a passive type DHR system has many advantages over an active one, designing a well coordinated passive system is usually more difficult than designing an effective active system. This is mainly because a cooling flow control is made directly by the system designer in an active system, while it is determined automatically by an intricate balance between the flow head loss and natural circulation head generation obtained from the density difference through the whole thermal flow system. To this end, securing a sufficient natural-circulation flow becomes one of the primary challenges for designing a reliable and successful Dh system in passive. In a current pool-type Sf design, an internal cooling flow path from the hot sodium pool to the cold pool is somewhat ambiguous owing to the split flow ratio formed in parallel paths between the intermediate heat exchangers (IHXs) and decay heat exchangers (DHXs), which results in a large uncertainty in the DHX shell-side flowrate and corresponding heat transfer to the DHR sodium loops. To improve passive the DHR performance, we proposed a new design concept with a simplified flow path from the hot pool to the cold pool through a unified flow path serially passing the DHX and IHX units. The present study aims at introducing the innovative design concept of the combined IHX-DHX unit and evaluating its design features in view of the heat transfer capability. From a comparison of the CHX performance designed by a one-dimensional approach with that made by a CFD analysis, it was quantitatively obtained that the difference in heat transfer rate is about 5.7%. It was also found that unexpected bypass flow in the shell-side CHX unit gave rise to a discrepancy

  17. Evaluating Maternity Units: a prospective cohort study of freestanding midwife-led primary maternity units in New Zealand-clinical outcomes.

    Science.gov (United States)

    Grigg, Celia P; Tracy, Sally K; Tracy, Mark; Daellenbach, Rea; Kensington, Mary; Monk, Amy; Schmied, Virginia

    2017-08-29

    To compare maternal and neonatal birth outcomes and morbidities associated with the intention to give birth in a freestanding primary level midwife-led maternity unit (PMU) or tertiary level obstetric-led maternity hospital (TMH) in Canterbury, Aotearoa/New Zealand. Prospective cohort study. 407 women who intended to give birth in a PMU and 285 women who intended to give birth at the TMH in 2010-2011. All of the women planning a TMH birth were 'low risk', and 29 of the PMU cohort had identified risk factors. Mode of birth, Apgar score of less than 7 at 5 min and neonatal unit admission. labour onset, analgesia, blood loss, third stage of labour management, perineal trauma, non-pharmacological pain relief, neonatal resuscitation, breastfeeding, gestational age at birth, birth weight, severe morbidity and mortality. Women who planned a PMU birth were significantly more likely to have a spontaneous vaginal birth (77.9%vs62.3%, adjusted OR (AOR) 1.61, 95% CI 1.08 to 2.39), and significantly less likely to have an instrumental assisted vaginal birth (10.3%vs20.4%, AOR 0.59, 95% CI 0.37 to 0.93). The emergency and elective caesarean section rates were not significantly different (emergency: PMU 11.6% vs TMH 17.5%, AOR 0.88, 95% CI 0.55 to 1.40; elective: PMU 0.7% vs TMH 2.1%, AOR 0.34, 95% CI 0.08 to 1.41). There were no significant differences between the cohorts in rates of 5 min Apgar score of maternity units as physically safe places for well women to plan to give birth, with these women having higher rates of spontaneous vaginal births and lower rates of interventions and their associated morbidities than those who planned a tertiary hospital birth, with no differences in neonatal outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Position paper -- Tank ventilation system design air flow rates

    International Nuclear Information System (INIS)

    Goolsby, G.K.

    1995-01-01

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems

  19. Coronary diastolic pressure-flow relation and zero flow pressure explained on the basis of intramyocardial compliance

    NARCIS (Netherlands)

    Spaan, J. A.

    1985-01-01

    In the controversy about the mechanisms determining the high zero flow pressures and the further interpretation of coronary diastolic pressure flow relations, this paper takes a stand in favor of intramyocardial compliance as the primary cause of the high zero flow pressures. An attempt has been

  20. Using Crossflow for Flow Measurements and Flow Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gurevich, A.; Chudnovsky, L.; Lopeza, A. [Advanced Measurement and Analysis Group Inc., Ontario (Canada); Park, M. H. [Sungjin Nuclear Engineering Co., Ltd., Gyeongju (Korea, Republic of)

    2016-10-15

    Ultrasonic Cross Correlation Flow Measurements are based on a flow measurement method that is based on measuring the transport time of turbulent structures. The cross correlation flow meter CROSSFLOW is designed and manufactured by Advanced Measurement and Analysis Group Inc. (AMAG), and is used around the world for various flow measurements. Particularly, CROSSFLOW has been used for boiler feedwater flow measurements, including Measurement Uncertainty Recovery (MUR) reactor power uprate in 14 nuclear reactors in the United States and in Europe. More than 100 CROSSFLOW transducers are currently installed in CANDU reactors around the world, including Wolsung NPP in Korea, for flow verification in ShutDown System (SDS) channels. Other CROSSFLOW applications include reactor coolant gross flow measurements, reactor channel flow measurements in all channels in CANDU reactors, boiler blowdown flow measurement, and service water flow measurement. Cross correlation flow measurement is a robust ultrasonic flow measurement tool used in nuclear power plants around the world for various applications. Mathematical modeling of the CROSSFLOW agrees well with laboratory test results and can be used as a tool in determining the effect of flow conditions on CROSSFLOW output and on designing and optimizing laboratory testing, in order to ensure traceability of field flow measurements to laboratory testing within desirable uncertainty.

  1. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 Catchments (Version 2.1) for the Conterminous United States: Base Flow Index

    Science.gov (United States)

    This dataset represents the base flow index values within individual, local NHDPlusV2 catchments and upstream, contributing watersheds. Attributes of the landscape layer were calculated for every local NHDPlusV2 catchment and accumulated to provide watershed-level metrics. (See Supplementary Info for Glossary of Terms) The base-flow index (BFI) grid for the conterminous United States was developed to estimate (1) BFI values for ungaged streams, and (2) ground-water recharge throughout the conterminous United States (see Source_Information). Estimates of BFI values at ungaged streams and BFI-based ground-water recharge estimates are useful for interpreting relations between land use and water quality in surface and ground water. The bfi (%) was summarized by local catchment and by watershed to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).

  2. Flow and edge scour in current adjacent to stone covers

    DEFF Research Database (Denmark)

    Petersen, Thor U.; Sumer, B. Mutlu; Bøgelund, Jon

    2015-01-01

    This paper presents the results of an experimental investigation on edge scour adjacent to a stone cover laid on a sandy bed. The three-dimensional flow over the edge of the stone layer has been investigated by the use of particle image velocimetry. The flow measurements show a significant amount...... of turbulence in the primary flow near the junction between the stone layer and the sand bed and the formation of complex secondary-flow structures. The results show that the flow and the edge scour process in a steady current are governed by the size of the roughness elements and to some extent the side slope...... of the berm. The edge scour is caused by the combined action of the primary flow and the secondary flow. The primary flow stirs up the sediment and puts it into suspension, and the secondary flow carries it away from the junction between the stone layer and the sand bed, resulting in a scour hole forming...

  3. [Challenges in primary health care: the experience in Vila Mariana District, São Paulo, Brazil].

    Science.gov (United States)

    Villela, Wilza Vieira; Araújo, Eliane Cardoso de; Ribeiro, Sandra Aparecida; Cuginotti, Aloísio Punhagui; Hayana, Eliana Tiemi; Brito, Francisco Carlos de; Ramos, Luiz Roberto

    2009-06-01

    This article presents the results of a case study aimed at identifying challenges for the delivery of primary health care in a health district in the city of São Paulo, Brazil, considering comprehensiveness as a central device for organizing work at this level of care. Five units in the district's primary care network were studied. We collected the data by observing work routines and flows, conducting interviews with managers and health professionals from different backgrounds, and through focus groups with family health teams. The analysis shows a mismatch between users' characteristics and their presumed needs and the heterogeneity of the health professionals' perceptions concerning their work. Lack of staff and time and difficulties with referrals were the main problems identified by interviewees.

  4. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C; Girard, N; Lefebvre, H

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  5. Wildfire impacts on the processes that generate debris flows in burned watersheds

    Science.gov (United States)

    Parise, M.; Cannon, S.H.

    2012-01-01

    Every year, and in many countries worldwide, wildfires cause significant damage and economic losses due to both the direct effects of the fires and the subsequent accelerated runoff, erosion, and debris flow. Wildfires can have profound effects on the hydrologic response of watersheds by changing the infiltration characteristics and erodibility of the soil, which leads to decreased rainfall infiltration, significantly increased overland flow and runoff in channels, and movement of soil. Debris-flow activity is among the most destructive consequences of these changes, often causing extensive damage to human infrastructure. Data from the Mediterranean area and Western United States of America help identify the primary processes that result in debris flows in recently burned areas. Two primary processes for the initiation of fire-related debris flows have been so far identified: (1) runoff-dominated erosion by surface overland flow; and (2) infiltration-triggered failure and mobilization of a discrete landslide mass. The first process is frequently documented immediately post-fire and leads to the generation of debris flows through progressive bulking of storm runoff with sediment eroded from the hillslopes and channels. As sediment is incorporated into water, runoff can convert to debris flow. The conversion to debris flow may be observed at a position within a drainage network that appears to be controlled by threshold values of upslope contributing area and its gradient. At these locations, sufficient eroded material has been incorporated, relative to the volume of contributing surface runoff, to generate debris flows. Debris flows have also been generated from burned basins in response to increased runoff by water cascading over a steep, bedrock cliff, and incorporating material from readily erodible colluvium or channel bed. Post-fire debris flows have also been generated by infiltration-triggered landslide failures which then mobilize into debris flows. However

  6. Flow cytometry of human primary epidermal and follicular keratinocytes.

    Science.gov (United States)

    Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako

    2008-02-19

    The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis.

  7. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit

    Directory of Open Access Journals (Sweden)

    Rowena Almeida

    2016-01-01

    Full Text Available Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  8. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit.

    Science.gov (United States)

    Almeida, Rowena; Paterson, William G; Craig, Nancy; Hookey, Lawrence

    2016-01-01

    Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario) endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  9. Estimated United States Transportation Energy Use 2005

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C A; Simon, A J; Belles, R D

    2011-11-09

    A flow chart depicting energy flow in the transportation sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 31,000 trillion British Thermal Units (trBTUs) of energy were used throughout the United States in transportation activities. Vehicles used in these activities include automobiles, motorcycles, trucks, buses, airplanes, rail, and ships. The transportation sector is powered primarily by petroleum-derived fuels (gasoline, diesel and jet fuel). Biomass-derived fuels, electricity and natural gas-derived fuels are also used. The flow patterns represent a comprehensive systems view of energy used within the transportation sector.

  10. Intertextuality in Read-Alouds of Integrated Science-Literacy Units in Urban Primary Classrooms: Opportunities for the Development of Thought and Language

    Science.gov (United States)

    Varelas, Maria; Pappas, Christine C.

    2006-01-01

    The nature and evolution of intertextuality was studied in 2 urban primary-grade classrooms, focusing on read-alouds of an integrated science-literacy unit. The study provides evidence that both debunks deficit theories for urban children by highlighting funds of knowledge that these children bring to the classroom and the sense they make of them…

  11. The 15 September 1991 pyroclastic flows at Unzen Volcano (Japan): a flow model for associated ash-cloud surges

    Science.gov (United States)

    Fujii, Toshitsugu; Nakada, Setsuya

    1999-04-01

    Large-scale collapse of a dacite dome in the late afternoon of 15 September 1991 generated a series of pyroclastic-flow events at Unzen Volcano. Pyroclastic flows with a volume of 1×10 6 m 3 (as DRE) descended the northeastern slope of the volcano, changing their courses to the southeast due to topographic control. After they exited a narrow gorge, an ash-cloud surge rushed straight ahead, detaching the main body of the flow that turned and followed the topographic lows to the east. The surge swept the Kita-Kamikoba area, which had been devastated by the previous pyroclastic-flow events, and transported a car as far as 120 m. Following detachment, the surge lost its force after it moved several hundred meters, but maintained a high temperature. The deposits consist of a bottom layer of better-sorted ash (unit 1), a thick layer of block and ash (unit 2), and a thin top layer of fall-out ash (unit 3). Unit 2 overlies unit 1 with an erosional contact. The upper part of unit 2 grades into better-sorted ash. At distal block-and-ash flow deposits, the bottom part of unit 2 also consists of better-sorted ash, and the contact with the unit 1 deposits becomes ambiguous. Video footage of cascading pyroclastic flows during the 1991-1995 eruption, traveling over surfaces without any topographic barriers, revealed that lobes of ash cloud protruded intermittently from the moving head and sides, and that these lobes surged ahead on the ground surface. This fact, together with the inspection by helicopter shortly after the events, suggests that the protruded lobes consisted of better-sorted ash, and resulted in the deposits of unit 1. The highest ash-cloud plume at the Oshigadani valley exit, and the thickest deposition of fall-out ash over Kita-Kamikoba and Ohnokoba, indicate that abundant ash was also produced when the flow passed through a narrow gorge. In the model presented here, the ash clouds from the pyroclastic flows were composed of a basal turbulent current of high

  12. Fluid flow in crystalline rocks: Relationships between groundwater spring alignments and other surface lineations at Altnabreac, United Kingdom

    International Nuclear Information System (INIS)

    Brereton, N.R.; McEwen, T.J.; Lee, M.K.

    1987-01-01

    The Strath Halladale Granite in the region around Altnabreac, northern Scotland, United Kingdom, has been studied with a view to establishing a relationship between the regional distribution of faults and fracture zones, surface discharges of groundwater, and groundwater flow systems. A major component of the groundwater flow is through the rock fractures. Because of the extensive superficial cover the surface expression of major fractures was difficult to identify from the limited surface exposures. Geophysical surveys and aerial photography enabled the authors to define lineations which could be related to the presence of fractures. The areal distribution of groundwater spring discharges was mapped using thermal infrared line scan techniques. The distribution of these springs has been studied to assess their relationships to surface lineaments and to correlations with geophysical and fracture mapping data. copyright American Geophysical Union 1987

  13. Implementing the Comprehensive Unit-Based Safety Program (CUSP) to Improve Patient Safety in an Academic Primary Care Practice.

    Science.gov (United States)

    Pitts, Samantha I; Maruthur, Nisa M; Luu, Ngoc-Phuong; Curreri, Kimberly; Grimes, Renee; Nigrin, Candace; Sateia, Heather F; Sawyer, Melinda D; Pronovost, Peter J; Clark, Jeanne M; Peairs, Kimberly S

    2017-11-01

    While there is growing awareness of the risk of harm in ambulatory health care, most patient safety efforts have focused on the inpatient setting. The Comprehensive Unit-based Safety Program (CUSP) has been an integral part of highly successful safety efforts in inpatient settings. In 2014 CUSP was implemented in an academic primary care practice. As part of CUSP implementation, staff and clinicians underwent training on the science of safety and completed a two-question safety assessment survey to identify safety concerns in the practice. The concerns identified by team members were used to select two initial safety priorities. The impact of CUSP on safety climate and teamwork was assessed through a pre-post comparison of results on the validated Safety Attitudes Questionnaire. Ninety-six percent of staff completed science of safety training as part of CUSP implementation, and 100% of staff completed the two-question safety assessment. The most frequently identified safety concerns were related to medications (n = 11, 28.2), diagnostic testing (n = 9, 25), and communication (n = 5, 14). The CUSP team initially prioritized communication and infection control, which led to standardization of work flows within the practice. Six months following CUSP implementation, large but nonstatistically significant increases were found for the percentage of survey respondents who reported knowledge of the proper channels for questions about patient safety, felt encouraged to report safety concerns, and believed that the work setting made it easy to learn from the errors of others. CUSP is a promising tool to improve safety climate and to identify and address safety concerns within ambulatory health care. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  14. Time-dependent tritium inventories and flow rates in fuel cycle components of a tokamak fusion reactor

    International Nuclear Information System (INIS)

    Kuan, W.

    1995-01-01

    Time-dependent inventories and flow rates for several components of the fuel cycle are modeled and studied through the use of a new modular-type model for the dynamic simulation of the fuel cycle in a fusion reactor. The complex dynamic behavior in the modeled subsystems is analyzed using this new model. Preliminary results using fuel cycle design configurations similar to ITER are presented and analyzed. The inventories and flow rates inside the primary vacuum pumping, fuel cleanup unit and isotope separation system are studied. Ways to minimize the tritium inventory are also assessed. This was performed by looking at various design options that could be used to minimize tritium inventory for specific components. (orig.)

  15. MK-III function tests in JOYO. Primary main cooling pump

    International Nuclear Information System (INIS)

    Isozaki, Kazunori; Saito, Takakazu; Sumino, Kouzo; Karube, Kouji; Terano, Toshihiro; Sakaba, Hideo; Nakai, Satoru

    2004-06-01

    MK-III function test (SKS-1) that was carried out from October 17, 2001 through October 23, 2001 using MK-III transition core configuration and MK-III function tests (SKS-2) was carried out from January 27, 2003 through February 13, 2003 using MK-III core configuration. The major function tests results of primary cooling system were shown as follows; (1) The stability of the primary main pump flow control system was confirmed on both CAS (cascade) mode and Man (manual) mode. Also no divergence of flow and revolution of the pump were observed at step flow change disturbance. (2) The main motor was shifted to run-back flow control operation in about 54 seconds after scram. The flow rate and pump revolution at run-back operation of A and B cooling system were 167 m 3 /h and 117 rpm, 185m 3 /h and 118 rpm respectively. The pump revolution was within the design target revolution 122 rpm ± 8 rpm and the flow was over the 10% of the rated flow. (3) The pony motor was engaged in operation in about 39 seconds after the primary main pump trip. The flow rate and pump revolution at the pony motor operation of A and B cooling system were 180 m 3 /h and 124 rpm, 190 m 3 /h and 123 rpm respectively. These values were satisfied the design low limit of 93 rpm and 10% of the rated flow. (4) Free flow coast down time constant was longer than 10 seconds that was design shortest time at both the primary pump trip and run-back operation. (5) Pump over flow column sodium levels of both A and B cooling system at rated operating condition were NL-1550 mm and, NL-1468 mm respectively and were lower than NL-1581 mm of the design value. This result shows the new IHX pressure loss estimation was conservative. (6) It was confirmed that the primary main pump could operate with out scram for up to 0.6 seconds of external power supply loss. (author)

  16. Conceptualization of the predevelopment groundwater flow system and transient water-level responses in Yucca Flat, Nevada National Security Site, Nevada

    Science.gov (United States)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Elliott, Peggy E.; Laczniak, Randell J.

    2012-01-01

    Contaminants introduced into the subsurface of Yucca Flat, Nevada National Security Site, by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a set of contour maps developed to represent the hydraulic-head distribution within the two major aquifer systems underlying the area. Aquifers and confining units within these systems were identified and their extents delineated by merging and analyzing hydrostratigraphic framework models developed by other investigators from existing geologic information. Maps of the hydraulic-head distributions in the major aquifer systems were developed from a detailed evaluation and assessment of available water-level measurements. The maps, in conjunction with regional and detailed hydrogeologic cross sections, were used to conceptualize flow within and between aquifer systems. Aquifers and confining units are mapped and discussed in general terms as being one of two aquifer systems: alluvial-volcanic or carbonate. The carbonate aquifers are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater flow directions, approximated from potentiometric contours, are indicated on the maps and sections and discussed for the alluvial-volcanic and regional carbonate aquifers. Flow in the alluvial-volcanic aquifer generally is constrained by the bounding volcanic confining unit, whereas flow in the regional carbonate aquifer is constrained by the siliceous confining unit. Hydraulic heads in the alluvial-volcanic aquifer typically range from 2,400 to 2,530 feet and commonly are elevated about 20-100 feet above heads in the underlying regional carbonate

  17. 3. Workshop for IAEA ICSP on Integral PWR Design Natural Circulation Flow Stability and Thermo-hydraulic Coupling of Containment and Primary System during Accidents. Presentations

    International Nuclear Information System (INIS)

    2012-04-01

    Most advanced nuclear power plant designs adopted several kinds of passive systems. Natural circulation is used as a key driving force for many passive systems and even for core heat removal during normal operation such as NuScale, CAREM, ESBWR and Indian AHWR designs. Simulation of natural circulation phenomena is very challenging since the driving force of it is weak compared to forced circulation and involves a coupling between primary system and containment for integral type reactor. The IAEA ICSP (International Collaborative Standard Problem) on 'Integral PWR Design Natural Circulation Flow Stability and Thermo-hydraulic Coupling of Containment and Primary System during Accidents' was proposed within the CRP on 'Natural Circulation Phenomena, Modelling, and Reliability of Passive Systems that utilize Natural Circulation'. Oregon State University (OSU) of USA offered to host this ICSP. This ICSP plans to conduct the following experiments and blind/open simulations with system codes: 1. Quasi-steady state operation with different core power levels: Conduct quasi-steady state operation with step-wise increase of core power level in order to observe single phase natural circulation flow according to power level. The experimental facility and operating conditions for an integral PWR will be used. 2. Thermo-hydraulic Coupling between Primary system and Containment: Conduct a loss of feedwater transient with subsequent ADS blowdown and long term cooling to determine the progression of a loss of feedwater transient by natural circulation through primary and containment systems. These tests would examine the blowdown phase as well as the long term cooling using sump natural circulation by coupling the primary to containment systems. This data could be used for the evaluation of system codes to determine if they model specific phenomena in an accurate manner. OSU completed planned two ICSP tests in July 2011 and real initial and boundary conditions measured from the

  18. Ground-Water Flow Model of the Sierra Vista Subwatershed and Sonoran Portions of the Upper San Pedro Basin, Southeastern Arizona, United States, and Northern Sonora, Mexico

    Science.gov (United States)

    Pool, D.R.; Dickinson, Jesse

    2007-01-01

    A numerical ground-water model was developed to simulate seasonal and long-term variations in ground-water flow in the Sierra Vista subwatershed, Arizona, United States, and Sonora, Mexico, portions of the Upper San Pedro Basin. This model includes the simulation of details of the groundwater flow system that were not simulated by previous models, such as ground-water flow in the sedimentary rocks that surround and underlie the alluvial basin deposits, withdrawals for dewatering purposes at the Tombstone mine, discharge to springs in the Huachuca Mountains, thick low-permeability intervals of silt and clay that separate the ground-water flow system into deep-confined and shallow-unconfined systems, ephemeral-channel recharge, and seasonal variations in ground-water discharge by wells and evapotranspiration. Steady-state and transient conditions during 1902-2003 were simulated by using a five-layer numerical ground- water flow model representing multiple hydrogeologic units. Hydraulic properties of model layers, streamflow, and evapotranspiration rates were estimated as part of the calibration process by using observed water levels, vertical hydraulic gradients, streamflow, and estimated evapotranspiration rates as constraints. Simulations approximate observed water-level trends throughout most of the model area and streamflow trends at the Charleston streamflow-gaging station on the San Pedro River. Differences in observed and simulated water levels, streamflow, and evapotranspiration could be reduced through simulation of climate-related variations in recharge rates and recharge from flood-flow infiltration.

  19. Did contracting effect the use of primary health care units in Pakistan?

    Science.gov (United States)

    Malik, Muhammad Ashar; Van de Poel, Ellen; Van Doorslaer, Eddy

    2017-09-01

    For many years, Pakistan has had a wide network of Basic Health Units spread across the country, but their utilization by the population in rural and peri-urban areas has remained low. As of 2004, in an attempt to improve the utilization and performance of these public primary healthcare facilities, the government has gradually started contracting-in intergovernmental organizations to manage these BHUs. Using five nationally representative household surveys conducted between 2001 and 2012, and exploiting the gradual roll-out of this reform to apply a difference-in-difference approach, we evaluate its impact on BHU utilization. We find that contracting of the BHU management did not have any effect on health care use generally in the population, but it did significantly increase the use of BHU for childhood diarrhoea for the poor (by 4% points) and rural (3% points) households. These increases were accompanied by lower rates of self-treatment and private facilities usage. We do not find any significant effects on the self-reported satisfaction with BHU utilization. Our findings contrast with earlier small-scale studies that reported larger effects of the contracting of primary care in Pakistan. We speculate that the modest additional budget, the limited management authority of the contracting agency and the lack of clear performance indicators are reasons for the small impact of the contracting reform. Apparently critical aspects of services delivery such as location of BHUs, ineffective referral system and medical practice variation in public and private sectors have contributed to the overall low utilization of BHUs, yet these were beyond the scope of the contracting reform. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Temperature and flow distribution in planar SOFC stacks

    Directory of Open Access Journals (Sweden)

    Monica Østenstad

    1995-07-01

    Full Text Available Simulation of a planar Solid Oxide Fuel Cell stack requires the solution of the mass balances of the chemical species, the energy balances, the charge balance and the channel flow equations in order to compute the species concentrations, the temperature distributions, the current density and the channel flows. The unit cell geometry can be taken into account by combining detailed modeling of a unit cell with a homogenized model of a whole stack. In this study the effect of the asymmetric temperature distribution on the channel flows in a conventional cross-flow design has been investigated. The bidirectional cross-flow design is introduced, for which we can show more directional temperature and flow distributions.

  1. Implementation and development of methods for quantification of cerebral blood flow in absolute units using single Photon Emission Tomography (SPECT)

    International Nuclear Information System (INIS)

    Diaz Moreno, Rogelio Manuel; Sanchez Catasus, Carlos; Aguila Ruiz, Angel; Samper, J; Llibre, J.

    2007-01-01

    The aim of this work was to implement the graphical and spectral methods of quantification of cerebral blood flow in absolute units with Single photon emission computered tomography and compare the results of its application. Also, a third method was developed to calculate blood flow, modifying the spectral method. The obtained flow values were 43.6 + 6.1 ml/min/100 g; 43.3+ 8.2 ml/min/100 g and 43.0+4.7 ml/min/100 g, respectively. We conclude that these methods are easy, non invasive and can be made in our country's technological conditions. The main innovation in this work was the modification of the spectral method, with which it is possible to avoid some of the difficulties arisen in the other methods. Also, the use of the software allows high reproducibility and efficiency on the process. These methods can become a valuable tool to enhance clinical diagnosis and important biomedical research. (Author)

  2. Design process and instrumentation of a low NOx wire-mesh duct burner for micro-cogeneration unit

    Energy Technology Data Exchange (ETDEWEB)

    Ramadan, O.B.; Gauthier, J.E.D. [Carleton Univ., Ottawa, ON (Canada). Dept. of Mechanical and Aerospace Engineering; Hughes, P.M.; Brandon, R. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre

    2007-07-01

    Air pollution and global climate change have become a serious environmental problem leading to increasingly stringent government regulations worldwide. New designs and methods for improving combustion systems to minimize the production of toxic emissions, like nitrogen oxides (NOx) are therefore needed. In order to control smog, acid rain, ozone depletion, and greenhouse-effect warming, a reduction of nitrogen oxide is necessary. One alternative for combined electrical power and heat generation (CHP) are micro-cogeneration units which use a micro-turbine as a prime mover. However, to increase the efficiencies of these units, micro-cogeneration technology still needs to be developed further. This paper described the design process, building, and testing of a new low NOx wire-mesh duct burner (WMDB) for the development of a more efficient micro-cogeneration unit. The primary goal of the study was to develop a practical and simple WMDB, which produces low emissions by using lean-premixed surface combustion concept and its objectives were separated into four phases which were described in this paper. Phase I involved the design and construction of the burner. Phase II involved a qualitative flow visualization study for the duct burner premixer to assist the new design of the burner by introducing an efficient premixer that could be used in this new application. Phase III of this research program involved non-reacting flow modeling on the burner premixer flow field using a commercial computational fluid dynamic model. In phase IV, the reacting flow experimental investigation was performed. It was concluded that the burner successfully increased the quantity and the quality of the heat released from the micro-CHP unit and carbon monoxide emissions of less than 9 ppm were reached. 3 refs., 3 figs.

  3. Forecasting of cash flow from an enterprise’s principal activities

    OpenAIRE

    Kanapickienė, Rasa; Šlekienė, Vaida

    2008-01-01

    The article deals with the forecasting of a cash flow from primary activities of an enterprise. Different mathematical methods are applied to forecast cash flow. Cash flow forecasts are often introduced in the project of the enterprise budget. Some scientific sources state that it is possible to forecast cash flow from primary activities of an enterprise according to its historical financial data by the means of regression analysis. These sources suggest various models of regression analysis ...

  4. Hydrogeologic Framework Model for the Saturated Zone Site Scale flow and Transport Model

    Energy Technology Data Exchange (ETDEWEB)

    T. Miller

    2004-11-15

    The purpose of this report is to document the 19-unit, hydrogeologic framework model (19-layer version, output of this report) (HFM-19) with regard to input data, modeling methods, assumptions, uncertainties, limitations, and validation of the model results in accordance with AP-SIII.10Q, Models. The HFM-19 is developed as a conceptual model of the geometric extent of the hydrogeologic units at Yucca Mountain and is intended specifically for use in the development of the ''Saturated Zone Site-Scale Flow Model'' (BSC 2004 [DIRS 170037]). Primary inputs to this model report include the GFM 3.1 (DTN: MO9901MWDGFM31.000 [DIRS 103769]), borehole lithologic logs, geologic maps, geologic cross sections, water level data, topographic information, and geophysical data as discussed in Section 4.1. Figure 1-1 shows the information flow among all of the saturated zone (SZ) reports and the relationship of this conceptual model in that flow. The HFM-19 is a three-dimensional (3-D) representation of the hydrogeologic units surrounding the location of the Yucca Mountain geologic repository for spent nuclear fuel and high-level radioactive waste. The HFM-19 represents the hydrogeologic setting for the Yucca Mountain area that covers about 1,350 km2 and includes a saturated thickness of about 2.75 km. The boundaries of the conceptual model were primarily chosen to be coincident with grid cells in the Death Valley regional groundwater flow model (DTN: GS960808312144.003 [DIRS 105121]) such that the base of the site-scale SZ flow model is consistent with the base of the regional model (2,750 meters below a smoothed version of the potentiometric surface), encompasses the exploratory boreholes, and provides a framework over the area of interest for groundwater flow and radionuclide transport modeling. In depth, the model domain extends from land surface to the base of the regional groundwater flow model (D'Agnese et al. 1997 [DIRS 100131], p 2). For the site

  5. Hydrogeologic Framework Model for the Saturated Zone Site Scale flow and Transport Model

    International Nuclear Information System (INIS)

    Miller, T.

    2004-01-01

    The purpose of this report is to document the 19-unit, hydrogeologic framework model (19-layer version, output of this report) (HFM-19) with regard to input data, modeling methods, assumptions, uncertainties, limitations, and validation of the model results in accordance with AP-SIII.10Q, Models. The HFM-19 is developed as a conceptual model of the geometric extent of the hydrogeologic units at Yucca Mountain and is intended specifically for use in the development of the ''Saturated Zone Site-Scale Flow Model'' (BSC 2004 [DIRS 170037]). Primary inputs to this model report include the GFM 3.1 (DTN: MO9901MWDGFM31.000 [DIRS 103769]), borehole lithologic logs, geologic maps, geologic cross sections, water level data, topographic information, and geophysical data as discussed in Section 4.1. Figure 1-1 shows the information flow among all of the saturated zone (SZ) reports and the relationship of this conceptual model in that flow. The HFM-19 is a three-dimensional (3-D) representation of the hydrogeologic units surrounding the location of the Yucca Mountain geologic repository for spent nuclear fuel and high-level radioactive waste. The HFM-19 represents the hydrogeologic setting for the Yucca Mountain area that covers about 1,350 km2 and includes a saturated thickness of about 2.75 km. The boundaries of the conceptual model were primarily chosen to be coincident with grid cells in the Death Valley regional groundwater flow model (DTN: GS960808312144.003 [DIRS 105121]) such that the base of the site-scale SZ flow model is consistent with the base of the regional model (2,750 meters below a smoothed version of the potentiometric surface), encompasses the exploratory boreholes, and provides a framework over the area of interest for groundwater flow and radionuclide transport modeling. In depth, the model domain extends from land surface to the base of the regional groundwater flow model (D'Agnese et al. 1997 [DIRS 100131], p 2). For the site-scale SZ flow model, the HFM

  6. Primary vesicles, vesicle-rich segregation structures and recognition of primary and secondary porosities in lava flows from the Paraná igneous province, southern Brazil

    Science.gov (United States)

    Barreto, Carla Joana S.; de Lima, Evandro F.; Goldberg, Karin

    2017-04-01

    This study focuses on a volcanic succession of pāhoehoe to rubbly lavas of the Paraná-Etendeka Province exposed in a single road profile in southernmost Brazil. This work provides an integrated approach for examining primary vesicles and vesicle-rich segregation structures at the mesoscopic scale. In addition, this study provides a quantitative analysis of pore types in thin section. We documented distinct distribution patterns of vesicle and vesicle-rich segregation structures according to lava thickness. In compound pāhoehoe lavas, the cooling allows only vesicles (pipe vesicles to be frozen into place. In inflated pāhoehoe lavas, vesicles of different sizes are common, including pipe vesicles, and also segregation structures such as proto-cylinders, cylinders, cylinder sheets, vesicle sheets, and pods. In rubbly lavas, only vesicles of varying sizes occur. Gas release from melt caused the formation of primary porosity, while hydrothermal alteration and tectonic fracturing are the main processes that generated secondary porosity. Although several forms of porosity were created in the basaltic lava flows, the precipitation of secondary minerals within the pores has tended to reduce the original porosities. Late-stage fractures could create efficient channel networks for possible hydrocarbon/groundwater migration and entrapment owing to their ability to connect single pores. Quantitative permeability data should be gathered in future studies to confirm the potential of these lavas for store hydrocarbons or groundwater.

  7. Flow Cytometry Section

    Data.gov (United States)

    Federal Laboratory Consortium — The primary goal of the Flow Cytometry Section is to provide the services of state-of-the-art multi-parameter cellular analysis and cell sorting for researchers and...

  8. Study of the heat transport primary system flow of Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Coutsiers, Eduardo E.; Moreno, Carlos A.; Pomerantz, Marcelo E.

    1999-01-01

    In this work, the HTPS coolant channels flow and associate aleatory errors are estimated. The objective of this estimation is to verify the validity of the flow calculated using the Canadian thermalhydraulic design code 'NUCIRC'. From measurements it can also be observed the evolution of the calculated flow with power of the reactor and to correct the maximum flow with power. The percentage of standard deviation discrepancies of flow estimated by measurements and those calculated using NUCIRC code is 5,7%. As the average aleatory error in flow estimation is 8,0%, it is concluded that the flow distribution calculated using NUCIRC is representative of the current state of the reactor channels. (author)

  9. Inlet Geomorphology Evolution Work Unit

    Science.gov (United States)

    2015-10-30

    Coastal Inlets Research Program Inlet Geomorphology Evolution Work Unit The Inlet Geomorphology Evolution work unit of the CIRP develops methods...morphologic response. Presently, the primary tool of the Inlet Geomorphology Evolution work unit is the Sediment Mobility Tool (SMT), which allows the user

  10. The presidential politics of climate discourse: energy frames, policy, and political tactics from the 2016 Primaries in the United States

    OpenAIRE

    Brown, George; Sovacool, Benjamin K

    2017-01-01

    his study presents the results of an investigation into the frequency in which four candidates of the 2016 United States Presidential Primary season communicated their political positions on climate change, and how they subsequently framed these stances in numerous contextual drivers alongside energy policies. A systematic content analysis of political debates, campaign speeches, and press statements reveals how Hillary Clinton, Bernie Sanders, Donald Trump, and Ted Cruz undertook in vote-see...

  11. Primary Maternity Units in rural and remote Australia: Results of a national survey.

    Science.gov (United States)

    Kruske, Sue; Kildea, Sue; Jenkinson, Bec; Pilcher, Jennifer; Robin, Sarah; Rolfe, Margaret; Kornelsen, Jude; Barclay, Lesley

    2016-09-01

    Primary Maternity Units (PMUs) offer less expensive and potentially more sustainable maternity care, with comparable or better perinatal outcomes for normal pregnancy and birth than higherlevel units. However, little is known about how these maternity services operate in rural and remote Australia, in regards to location, models of care, service structure, support mechanisms or sustainability. This study aimed to confirm and describe how they operate. a descriptive, cross-sectional study was undertaken, utilising a 35-item survey to explore current provision of maternity care in rural and remote PMUs across Australia. Data were subjected to simple descriptive statistics and thematic analysis for free text answers. Only 17 PMUs were identified in rural and remote areas of Australia. All 17 completed the survey. the PMUs were, on average, 56km or 49minutes from their referral service and provided care to an average of 59 birthing women per year. Periodic closures or downgrading of services was common. Low-risk eligibility criteria were universally used, but with some variability. Medically-led care was the most widely available model of care. In most PMUs midwives worked shift work involving both nursing and midwifery duties, with minimal uptake of recent midwifery workforce innovations. Perceived enablers of, and threats to, sustainability were reported. a small number of PMUs operate in rural Australia, and none in remote areas. Continuing overreliance on local medical support, and under-utilisation of the midwifery workforce constrain the restoration of maternity services to rural and remote Australia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. The Physical Economy of the United States of America.

    Science.gov (United States)

    Gierlinger, Sylvia; Krausmann, Fridolin

    2012-06-01

    The United States is not only the world's largest economy, but it is also one of the world's largest consumers of natural resources. The country, which is inhabited by some 5% of the world's population, uses roughly one-fifth of the global primary energy supply and 15% of all extracted materials. This article explores long-term trends and patterns of material use in the United States. Based on a material flow account (MFA) that is fully consistent with current standards of economy-wide MFAs and covers domestic extraction, imports, and exports of materials for a 135-year period, we investigated the evolution of the U.S. industrial metabolism. This process was characterized by an 18-fold increase in material consumption, a multiplication of material use per capita, and a shift from renewable biomass toward mineral and fossil resources. In spite of considerable improvements in material intensity, no dematerialization has happened so far; in contrast to other high-income countries, material use has not stabilized since the 1970s, but has continued to grow. This article compares patterns and trends of material use in the United States with those in Japan and the United Kingdom and discusses the factors underlying the disproportionately high level of U.S. per capita resource consumption.

  13. Flow units classification for geostatisitical three-dimensional modeling of a non-marine sandstone reservoir: A case study from the Paleocene Funing Formation of the Gaoji Oilfield, east China

    Science.gov (United States)

    Zhang, Penghui; Zhang, Jinliang; Wang, Jinkai; Li, Ming; Liang, Jie; Wu, Yingli

    2018-05-01

    Flow units classification can be used in reservoir characterization. In addition, characterizing the reservoir interval into flow units is an effective way to simulate the reservoir. Paraflow units (PFUs), the second level of flow units, are used to estimate the spatial distribution of continental clastic reservoirs at the detailed reservoir description stage. In this study, we investigate a nonroutine methodology to predict the external and internal distribution of PFUs. The methodology outlined enables the classification of PFUs using sandstone core samples and log data. The relationships obtained between porosity, permeability and pore throat aperture radii (r35) values were established for core and log data obtained from 26 wells from the Funing Formation, Gaoji Oilfield, Subei Basin, China. The present study refines predicted PFUs at logged (0.125-m) intervals, whose scale is much smaller than routine methods. Meanwhile, three-dimensional models are built using sequential indicator simulation to characterize PFUs in wells. Four distinct PFUs are classified and located based on the statistical methodology of cluster analysis, and each PFU has different seepage ability. The results of this study demonstrate the obtained models are able to quantify reservoir heterogeneity. Due to different petrophysical characteristics and seepage ability, PFUs have a significant impact on the distribution of the remaining oil. Considering these allows a more accurate understanding of reservoir quality, especially within non-marine sandstone reservoirs.

  14. Integrated soft sensor model for flow control.

    Science.gov (United States)

    Aijälä, G; Lumley, D

    2006-01-01

    Tighter discharge permits often require wastewater treatment plants to maximize utilization of available facilities in order to cost-effectively reach these goals. Important aspects are minimizing internal disturbances and using available information in a smart way to improve plant performance. In this study, flow control throughout a large highly automated wastewater treatment plant (WWTP) was implemented in order to reduce internal disturbances and to provide a firm foundation for more advanced process control. A modular flow control system was constructed based on existing instrumentation and soft sensor flow models. Modules were constructed for every unit process in water treatment and integrated into a plant-wide model. The flow control system is used to automatically control recirculation flows and bypass flows at the plant. The system was also successful in making accurate flow estimations at points in the plant where it is not possible to have conventional flow meter instrumentation. The system provides fault detection for physical flow measuring devices. The module construction allows easy adaptation for new unit processes added to the treatment plant.

  15. Proposition of primary methods for nitrogen oxides emissions reduction at coal-fired 200 MW power unit (Yugoslavia)

    International Nuclear Information System (INIS)

    Repic, B.; Mladenovic, R.; Crnomarkovic, N.

    1997-01-01

    The combustion of coal is followed by increased pollution of the environment with toxic products. Together with the generation of other pollutants, the emission of nitrogen oxides (NO x ) represents, due to its high toxicity, a great environmental risk. Appropriate measures must be taken for lowering NO x emission, both on new facilities and those already in operation. Basic technologies (primary reduction methods) of several generations, developed until now and used in practice, are presented in the paper. The technologies applicable on domestic facilities and adjusted to domestic coals have been given particular consideration. Proposition of primary methods for NO x emission reduction at coal-fired 200 MW power unit at TPS 'Nikola Tesla' is analyzed. The following methods have been considered in detail: flue gases recirculation, multi-stage combustion, low-NO x burners, additional over-fire air, multi-stage air intake into the furnace, staged fuel injection, grinding fineness increase, etc. Considerations were performed according to existing constructive characteristics of the furnace and the burners, and characteristics of used fuels, i. e. lignites from Kolubara pit. (Author)

  16. Performance of the Subsurface Flow Wetland in Batch Flow for Municipal Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Abolfazle Rahmani sani

    2009-06-01

    Full Text Available Subsurface flow wetlands are one of the natural treatment methods used for municipal and industrial wastewater treatment that are economical in terms of energy consumption and cost-effectiveness. Much research has been conducted on wetland operation with continuous flow but not enough information is available on batch flow. This study investigates wetland efficiency in batch flow. For the purposes of this research, two pretreatment units of the anaerobic pond type with digestion pits and two subsurface flow wetlands with a 2-day detention time were built on the pilot scale. The cells were charged with sand of 5 mm effective size, uniformity coefficient of 1.5, and a porosity of 35%. One wetland cell and one pretreatment unit were used as control. The municipal wastewater selected to be monitored for the one-year study period had a flow rate of 26 m3/day and average BOD5 of 250mg/l, TSS of 320mg/l, TKN of 35mg/l, TP of 12mg/l and TC of 2×108 MPN/100ml from Sabzevar Wastewater Treatment Plant. The average removal efficiencies of BOD5,TSS,TKN,TP, and TC in the continuous flow for the combined control pretreatment and wetland cell were 77.2%, 92%, 91%, 89%, 96.5% while the same values for the batch flow for the combined experimental pretreatment and wetland cell were 92%, 97%, 97.5%, 97%, and 99.75%, respectively. The removal efficiency in the subsurface flow wetlands in the batch flow was higher than that of the continuous flow. Thus, for wastewaters with a high pollution level, the batch flow can be used in cell operation in cases where there is not enough land for spreading the wetland cell.

  17. Efficiency of osmotic pipe flows

    DEFF Research Database (Denmark)

    Haaning, Louise Sejling; Jensen, Kaare Hartvig; Helix Nielsen, Claus

    2013-01-01

    efficiency of these flows is limited by the presence of “unstirred” concentration boundary layers near the tube walls, and our primary aim is to understand and quantify these layers and their effect on the flow. We measure the outlet flow rate Qout while varying the inlet flow rate Q*, concentration c......We present experiments and theory for flows of sugar or salt solutions in cylindrical tubes with semipermeable walls (hollow fiber membranes) immersed in water, quantifying the strength of the osmotic driving force in relation to the dimensionless parameters that specify the system. The pumping...

  18. PSYCHOTROPIC MEDICINE PRESCRIPTIONS IN A PRIMARY CARE UNIT IN A BIG CITY OF SÃO PAULO STATE

    Directory of Open Access Journals (Sweden)

    Tatiana Oliveira da Silva

    2013-03-01

    Full Text Available Aiming toknowthe consumptionprofileof psychotropic drugs inpopulation ofperipheral region of abig cityof São Paulo State, 800 prescriptionsfromaPrimary CareUnitareassessedaccordingto344/98-SVS/MS.In that timethecontrolof these drugs were mademanually.The results showed1371 drugsdispensedandamong those1134were psychotropic.Thetotal was64,513pillunits, an average of 107 units with 1.7 drugs per prescription, while82.1% came from public services. The total number of drugs prescribed per prescription had themajority (60.0% onedrug, 20.3%, two drugs, three drugs 11.6%, 6.6% four or moremedications, including those not controlled (14% . Twenty drugswerenot on the standard list.Of controlled, 78.4% belonged to theclassC1 and21.6% toB1.There is a large consumption ofpsychotropic medications for thispoorpopulation, with a prevalence of antidepressants. Thesubsequent implementation of the computerized system significantly reduced the units dispensed,indicating that forms of management are factors to be considered in the rational use of drugs,such as the use of technologies and also the wide range of approaches to health education, such astraining of health professionals, including prescribers

  19. Pore size determination using normalized J-function for different hydraulic flow units

    Directory of Open Access Journals (Sweden)

    Ali Abedini

    2015-06-01

    Full Text Available Pore size determination of hydrocarbon reservoirs is one of the main challenging areas in reservoir studies. Precise estimation of this parameter leads to enhance the reservoir simulation, process evaluation, and further forecasting of reservoir behavior. Hence, it is of great importance to estimate the pore size of reservoir rocks with an appropriate accuracy. In the present study, a modified J-function was developed and applied to determine the pore radius in one of the hydrocarbon reservoir rocks located in the Middle East. The capillary pressure data vs. water saturation (Pc–Sw as well as routine reservoir core analysis include porosity (φ and permeability (k were used to develop the J-function. First, the normalized porosity (φz, the rock quality index (RQI, and the flow zone indicator (FZI concepts were used to categorize all data into discrete hydraulic flow units (HFU containing unique pore geometry and bedding characteristics. Thereafter, the modified J-function was used to normalize all capillary pressure curves corresponding to each of predetermined HFU. The results showed that the reservoir rock was classified into five separate rock types with the definite HFU and reservoir pore geometry. Eventually, the pore radius for each of these HFUs was determined using a developed equation obtained by normalized J-function corresponding to each HFU. The proposed equation is a function of reservoir rock characteristics including φz, FZI, lithology index (J*, and pore size distribution index (ɛ. This methodology used, the reservoir under study was classified into five discrete HFU with unique equations for permeability, normalized J-function and pore size. The proposed technique is able to apply on any reservoir to determine the pore size of the reservoir rock, specially the one with high range of heterogeneity in the reservoir rock properties.

  20. Disinfection of an advanced primary effluent using peracetic acid or ultraviolet radiation for its reuse in public services.

    Science.gov (United States)

    Julio, Flores R; Hilario, Terres-Peña; Mabel, Vaca M; Raymundo, López C; Arturo, Lizardi-Ramos; Ma Neftalí, Rojas-Valencia

    2015-03-01

    The disinfection of a continuous flow of an effluent from an advanced primary treatment (coagulation-flocculation-sedimentation) with or without posterior filtration, using either peracetic acid (PAA) or ultraviolet (UV) radiation was studied. We aimed to obtain bacteriological quality to comply with the microbiological standard established in the Mexican regulations for treated wastewater reuse (NOM-003-SEMARNAT-1997), i.e., less than 240 MPN (most probable number) FC/100 mL. The concentrations of PAA were 10, 15, and 20 mg/L, with contact times of 10, and 15 min. Fecal coliforms (FC) inactivation ranged from 0.93 up to 6.4 log units, and in all cases it reached the limits set by the mentioned regulation. Water quality influenced the PAA disinfection effectiveness. An efficiency of 91% was achieved for the unfiltered effluent, as compared to 99% when wastewater was filtered. UV radiation was applied to wastewater flows of 21, 30 and 39 L/min, with dosages from 1 to 6 mJ/cm². This treatment did not achieve the bacteriological quality required for treated wastewater reuse, since the best inactivation of FC was 1.62 log units, for a flow of 21 L/min of filtered wastewater and a UV dosage of 5.6 mJ/cm².

  1. Holocene debris flows on the Colorado Plateau: The influence of clay mineralogy and chemistry

    Science.gov (United States)

    Webb, R.H.; Griffiths, P.G.; Rudd, L.P.

    2008-01-01

    Holocene debris flows do not occur uniformly on the Colorado Plateau province of North America. Debris flows occur in specific areas of the plateau, resulting in general from the combination of steep topography, intense convective precipitation, abundant poorly sorted material not stabilized by vegetation, and the exposure of certain fine-grained bedrock units in cliffs or in colluvium beneath those cliffs. In Grand and Cataract Canyons, fine-grained bedrock that produces debris flows contains primarily single-layer clays - notably illite and kaolinite - and has low multilayer clay content. This clay-mineral suite also occurs in the colluvium that produces debris flows as well as in debris-flow deposits, although unconsolidated deposits have less illite than the source bedrock. We investigate the relation between the clay mineralogy and major-cation chemistry of fine-grained bedrock units and the occurrence of debris flows on the entire Colorado Plateau. We determined that 85 mapped fine-grained bedrock units potentially could produce debris flows, and we analyzed clay mineralogy and major-cation concentration of 52 of the most widely distributed units, particularly those exposed in steep topography. Fine-grained bedrock units that produce debris flows contained an average of 71% kaolinite and illite and 5% montmorillonite and have a higher concentration of potassium and magnesium than nonproducing units, which have an average of 51% montmorillonite and a higher concentration of sodium. We used multivariate statistics to discriminate fine-grained bedrock units with the potential to produce debris flows, and we used digital-elevation models and mapped distribution of debris-flow producing units to derive a map that predicts potential occurrence of Holocene debris flows on the Colorado Plateau. ?? 2008 Geological Society of America.

  2. Research on one-dimensional two-phase flow

    International Nuclear Information System (INIS)

    Adachi, Hiromichi

    1988-10-01

    In Part I the fundamental form of the hydrodynamic basic equations for a one-dimensional two-phase flow (two-fluid model) is described. Discussions are concentrated on the treatment of phase change inertial force terms in the equations of motion and the author's equations of motion which have a remarkable uniqueness on the following three points. (1) To express force balance of unit mass two-phase fluid instead of that of unit volume two-phase fluid. (2) To pick up the unit existing mass and the unit flowing mass as the unit mass of two-phase fluid. (3) To apply the kinetic energy principle instead of the momentum low in the evaluation of steady inertial force term. In these three, the item (1) is for excluding a part of momentum change or kinetic energy change due to mass change of the examined part of fluid, which is independent of force. The item (2) is not to introduce a phenomenological physical model into the evaluation of phase change inertial force term. And the item (3) is for correctly applying the momentum law taking into account the difference of representative velocities between the main flow fluid (vapor phase or liquid phase) and the phase change part of fluid. In Part II, characteristics of various kinds of high speed two-phase flow are clarified theoretically by the basic equations derived. It is demonstrated that the steam-water two-phase critical flow with violent flashing and the airwater two-phase critical flow without phase change can be described with fundamentally the same basic equations. Furthermore, by comparing the experimental data from the two-phase critical discharge test and the theoretical prediction, the two-phase discharge coefficient, C D , for large sharp-edged orifice is determined as the value which is not affected by the experimental facility characteristics, etc. (author)

  3. Hierarchy of facies of pyroclastic flow deposits generated by Laacher See type eruptions

    Science.gov (United States)

    Freundt, A.; Schmincke, H.-U.

    1985-04-01

    The upper Quaternary pyroclastic flow deposits of Laacher See volcano show compositional and structural facies variations on four different scales: (1) eruptive units of pyroclastic flows, composed of many flow units; (2) depositional cycles of as many as five flow units; flow units containing (3) regional intraflow-unit facies; and (4) local intraflow-unit subfacies. These facies can be explained by successively overlapping processes beginning in the magma column and ending with final deposition. The pyroclastic flow deposits thus reflect major aspects of the eruptive history of Laacher See volcano: (a) drastic changes in eruptive mechanism due to increasing access of water to the magma chamber and (b) change in chemical composition and crystal and gas content as evacuation of a compositionally zoned magma column progressed. The four scales of facies result from four successive sets of processes: (1) differentiation in the magma column and external factors governing the mechanism of eruption; (2) temporal variations of factors inducing eruption column collapse; (3) physical conditions in the eruption column and the way in which its collapse proceeds; and (4) interplay of flow-inherent and morphology-induced transport mechanics.

  4. Comparison of the effectiveness of high flow nasal oxygen cannula vs. standard non-rebreather oxygen face mask in post-extubation intensive care unit patients.

    Science.gov (United States)

    Brotfain, Evgeni; Zlotnik, Alexander; Schwartz, Andrei; Frenkel, Amit; Koyfman, Leonid; Gruenbaum, Shaun E; Klein, Moti

    2014-11-01

    Optimal oxygen supply is the cornerstone of the management of critically ill patients after extubation, especially in patients at high risk for extubation failure. In recent years, high flow oxygen system devices have offered an appropriate alternative to standard oxygen therapy devices such as conventional face masks and nasal prongs. To assess the clinical effects of high flow nasal cannula (HFNC) compared with standard oxygen face masks in Intensive Care Unit (ICU) patients after extubation. We retrospectively analyzed 67 consecutive ventilated critical care patients in the ICU over a period of 1 year. The patients were allocated to two treatment groups: HFNC (34 patients, group 1) and non-rebreathing oxygen face mask (NRB) (33 patients, group 2). Vital respiratory and hemodynamic parameters were assessed prior to extubation and 6 hours after extubation. The primary clinical outcomes measured were improvement in oxygenation, ventilation-free days, re-intubation, ICU length of stay, and mortality. The two groups demonstrated similar hemodynamic patterns before and after extubation. The respiratory rate was slightly elevated in both groups after extubation with no differences observed between groups. There were no statistically significant clinical differences in PaCO2. However, the use of HFNC resulted in improved PaO2/FiO2 post-extubation (P < 0.05). There were more ventilator-free days in the HFNC group (P< 0.05) and fewer patients required reintubation (1 vs. 6). There were no differences in ICU length of stay or mortality. This study demonstrated better oxygenation for patients treated with HFNC compared with NRB after extubation. HFNC may be more effective than standard oxygen supply devices for oxygenation in the post-extubation period.

  5. Tracer technology modeling the flow of fluids

    CERN Document Server

    Levenspiel, Octave

    2012-01-01

    A vessel’s behavior as a heat exchanger, absorber, reactor, or other process unit is dependent upon how fluid flows through the vessel.  In early engineering, the designer would assume either plug flow or mixed flow of the fluid through the vessel.  However, these assumptions were oftentimes inaccurate, sometimes being off by a volume factor of 100 or more.  The result of this unreliable figure produced ineffective products in multiple reaction systems.   Written by a pioneering researcher in the field of chemical engineering, the tracer method was introduced to provide more accurate flow data.  First, the tracer method measured the actual flow of fluid through a vessel.  Second, it developed a suitable model to represent the flow in question.  Such models are used to follow the flow of fluid in chemical reactors and other process units, like in rivers and streams, or solid and porous structures.  In medicine, the tracer method is used to study the flow of chemicals—harmful  and harmless—in the...

  6. A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units

    DEFF Research Database (Denmark)

    Sanseverino, Eleonora Riva; Quang, Ninh Nguyen; Zizzo, Gaetano

    2013-01-01

    In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations...... of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have...

  7. Flow analysis of HANARO flow simulated test facility

    International Nuclear Information System (INIS)

    Park, Yong-Chul; Cho, Yeong-Garp; Wu, Jong-Sub; Jun, Byung-Jin

    2002-01-01

    The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial critical in February, 1995. Many experiments should be safely performed to activate the utilization of the NANARO. A flow simulated test facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate core channels. This test facility must simulate similar flow characteristics to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the test facility. The computational flow analysis has been performed for the verification of flow structure and similarity of this test facility assuming that flow rates and pressure differences of the core channel are constant. The shapes of flow orifices were determined by the trial and error method based on the design requirements of core channel. The computer analysis program with standard k - ε turbulence model was applied to three-dimensional analysis. The results of flow simulation showed a similar flow characteristic with that of the HANARO and satisfied the design requirements of this test facility. The shape of flow orifices used in this numerical simulation can be adapted for manufacturing requirements. The flow rate and the pressure difference through core channel proved by this simulation can be used as the design requirements of the flow system. The analysis results will be verified with the results of the flow test after construction of the flow system. (author)

  8. Power Flow Distribution Strategy for Improved Power Electronics Energy Efficiency in Battery Storage Systems: Development and Implementation in a Utility-Scale System

    Directory of Open Access Journals (Sweden)

    Michael Schimpe

    2018-03-01

    Full Text Available Utility-scale battery storage systems typically consist of multiple smaller units contributing to the overall power dispatch of the system. Herein, the power distribution among these units is analyzed and optimized to operate the system with increased energy efficiency. To improve the real-life storage operation, a holistic system model for battery storage systems has been developed that enables a calculation of the energy efficiency. A utility-scale Second-Life battery storage system with a capacity of 3.3 MWh/3 MW is operated and evaluated in this work. The system is in operation for the provision of primary control reserve in combination with intraday trading for controlling the battery state of charge. The simulation model is parameterized with the system data. Results show that losses in power electronics dominate. An operational strategy improving the energy efficiency through an optimized power flow distribution within the storage system is developed. The power flow distribution strategy is based on the reduction of the power electronics losses at no-load/partial-load by minimizing their in-operation time. The simulation derived power flow distribution strategy is implemented in the real-life storage system. Field-test measurements and analysis prove the functionality of the power flow distribution strategy and reveal the reduction of the energy throughput of the units by 7%, as well as a significant reduction of energy losses in the units by 24%. The cost savings for electricity over the system’s lifetime are approximated to 4.4% of its investment cost.

  9. Crosslinked anion exchange membranes with primary diamine-based crosslinkers for vanadium redox flow battery application

    Science.gov (United States)

    Cha, Min Suc; Jeong, Hwan Yeop; Shin, Hee Young; Hong, Soo Hyun; Kim, Tae-Ho; Oh, Seong-Geun; Lee, Jang Yong; Hong, Young Taik

    2017-09-01

    A series of polysulfone-based crosslinked anion exchange membranes (AEMs) with primary diamine-based crosslinkers has been prepared via simple a crosslinking process as low-cost and durable membranes for vanadium redox flow batteries (VRFBs). Chloromethylated polysulfone is used as a precursor polymer for crosslinked AEMs (CAPSU-x) with different degrees of crosslinking. Among the developed AEMs, CAPSU-2.5 shows outstanding dimensional stability and anion (Cl-, SO42-, and OH-) conductivity. Moreover, CAPSU-2.5 exhibits much lower vanadium ion permeability (2.72 × 10-8 cm2 min-1) than Nafion 115 (2.88 × 10-6 cm2 min-1), which results in an excellent coulombic efficiency of 100%. The chemical and operational stabilities of the membranes have been investigated via ex situ soaking tests in 0.1 M VO2+ solution and in situ operation tests for 100 cycles, respectively. The excellent chemical, physical, and electrochemical properties of the CAPSU-2.5 membrane make it suitable for use in VRFBs.

  10. Factor structure and sex differences on the Wechsler Preschool and Primary Scale of Intelligence in China, Japan and United States.

    Science.gov (United States)

    Liu, Jianghong; Lynn, Richard

    2011-08-01

    This study presents data on the factor structure of the Wechsler Preschool and Primary Scale of Intelligence (WPPSI) and sex and cultural differences in WPPSI test scores among 5- and 6-year-olds from China, Japan, and the United States. Results show the presence of a verbal and nonverbal factor structure across all three countries. Sex differences on the 10 subtests were generally consistent, with a male advantage on a subtest of spatial abilities (Mazes). Males in the Chinese sample obtained significantly higher Full Scale IQ scores than females and had lower variability in their test scores. These observations were not present in the Japan and United States samples. Mean Full Scale IQ score in the Chinese sample was 104.1, representing a 4-point increase from 1988 to 2004.

  11. Instrument for measuring flow velocities

    International Nuclear Information System (INIS)

    Griffo, J.

    1977-01-01

    The design described here means to produce a 'more satisfying instrument with less cost' than comparable instruments known up to now. Instead of one single turbine rotor, two similar ones but with opposite blade inclination and sense of rotation are to be used. A cylindrical measuring body is carrying in its axis two bearing blocks whose shape is offering little flow resistance. On the shaft, supported by them, the two rotors run in opposite direction a relatively small axial distance apart. The speed of each rotor is picked up as pulse recurrence frequency by a transmitter and fed to an electronic measuring unit. Measuring errors as they are caused for single rotors by turbulent flow, profile distortion of the velocity, or viscous flow are to be eliminated by means of the contrarotating turbines and the subsequently added electronic unit, because in these cases the adulterating increase of the angular velocity of one rotor is compensated by a corresponding deceleration of the other rotor. The mean value then indicated by the electronic unit has high accurancy of measurement. (RW) [de

  12. CFD flow pattern analysis on primaryside of IHX for fast reactors

    International Nuclear Information System (INIS)

    Takano, Masahito; Mochizuki, Hiroyasu

    2011-01-01

    The present paper describes the CFD analysis on the primary-side of an intermediate heat exchange (IHX) which has the similar configurations as the IHX for the fast breeder reactor 'Monju'. The IHX is precisely modeled based on the discussion about meshing system. The present model is used for the heat transfer analysis under low-flowrate and natural circulation conditions. The IHX is a shell-and-tube type and counter-flow heat exchanger which has more than 3000 heat transfer tubes on the secondary side. Therefore, the flow pattern on the primary side gets complex. Measurement of flow pattern and temperature distribution on the primary-side of the real IHX are almost impossible. Since the heat transfer tubes of approximately 5 m in length are fixed at 7 plates with many flow holes and placed on the 23 circles with an appropriate lattice pitch, the number of meshes becomes enormous size. In order to overcome these problems, a separate model is discussed. In the present study, two models are discussed. The first one is a precise full-sector model with one flow entrance, 6 windows on the primary-side. The flow distributions are calculated changing inlet flow rate from 100% to 0.1% which is equivalent to 10 6 to 10 3 in the Reynolds numbers. The other model is a sector model with 8 chamber separated by 7 flow-rectifying plats. Pressure losses at each plate and chamber are calculated using this model. As a result of the analysis, since there is only a small flow deviation between the flow from the 6 windows under turbulent flow and laminar flow conditions, the sector model with one window is possible model in the calculation. The small radial velocity gradient is calculated from 23rd layer (outer heat transfer tube) to 10th layer. The distribution is not dependent on the flow rate. Axial flow distributions through the rectifying plates are unified from the entrance to the down-stream. The sector model is applicable to calculate the primary-side flow distributions

  13. Regional cerebral blood flow abnormalities in patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Cermik, Tevfik F.; Kaya, Meryem; Bedel, Deniz; Berkarda, Sakir; Yigitbasi, Oemer N.; Ugur-Altun, Betuel

    2007-01-01

    We assessed the alterations in regional cerebral blood flow (rCBF) in patients with primary hyperparathyroidism (PHP) before parathyroidectomy by semiquantitative analysis of brain single photon emission computed tomography (SPECT) images. Included in this prospective study were 14 patients (mean age 47.6 ± 10.4 years; 3 male, 11 female) and 10 control subjects (mean age 36.0 ± 8.5 years, 6 male, 4 female) were SPECT imaging was performed using a dual-headed gamma camera 60-90 min after intravenous administration of 925 MBq Tc-99m HMPAO. The corticocerebellar rCBF ratios were calculated from 52 brain areas and reference lower values (RLVs) were calculated from the rCBF ratios of control subjects. The regional ratios that were below the corresponding RLV were considered abnormal (hypoperfused). Hypoperfusion was shown in 171 out of 728 regions (23%) and there was a significant correlation between serum calcium, PTH levels and the sum of hypoperfused regions in the patient group (R = 0.75 and P = 0.001, and R = 0.75, P = 0.001, respectively). Significantly reduced rCBF were found in the following cortical regions: bilateral cingulate cortex, superior and inferior frontal cortex, anterior temporal cortex, precentral gyrus, postcentral gyrus and parietal cortex, and right posterior temporal cortex. Our results indicate that alterations in rCBF in patients with PHP can be demonstrated with brain SPECT. The correlation between serum calcium, PTH levels and the sum of hypoperfused regions indicates that there may be a strong relationship between rCBF abnormalities and increased levels of serum calcium and PTH. In addition, the degree of rCBF abnormalities could be determined by brain SPECT in PHP patients with or without psychiatric symptoms. (orig.)

  14. Regional cerebral blood flow abnormalities in patients with primary hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Cermik, Tevfik F. [Hospital of the University of Trakya, Department of Nuclear Medicine, Edirne (Turkey); Trakya Universitesi Hastanesi, Nukleer Tip Anabilim Dali, Gullapoglu Yerleskesi, Edirne (Turkey); Kaya, Meryem; Bedel, Deniz; Berkarda, Sakir; Yigitbasi, Oemer N. [Hospital of the University of Trakya, Department of Nuclear Medicine, Edirne (Turkey); Ugur-Altun, Betuel [Hospital of the University of Trakya, Department of Internal Medicine, Division of Endocrinology, Edirne (Turkey)

    2007-04-15

    We assessed the alterations in regional cerebral blood flow (rCBF) in patients with primary hyperparathyroidism (PHP) before parathyroidectomy by semiquantitative analysis of brain single photon emission computed tomography (SPECT) images. Included in this prospective study were 14 patients (mean age 47.6 {+-} 10.4 years; 3 male, 11 female) and 10 control subjects (mean age 36.0 {+-} 8.5 years, 6 male, 4 female) were SPECT imaging was performed using a dual-headed gamma camera 60-90 min after intravenous administration of 925 MBq Tc-99m HMPAO. The corticocerebellar rCBF ratios were calculated from 52 brain areas and reference lower values (RLVs) were calculated from the rCBF ratios of control subjects. The regional ratios that were below the corresponding RLV were considered abnormal (hypoperfused). Hypoperfusion was shown in 171 out of 728 regions (23%) and there was a significant correlation between serum calcium, PTH levels and the sum of hypoperfused regions in the patient group (R = 0.75 and P = 0.001, and R = 0.75, P = 0.001, respectively). Significantly reduced rCBF were found in the following cortical regions: bilateral cingulate cortex, superior and inferior frontal cortex, anterior temporal cortex, precentral gyrus, postcentral gyrus and parietal cortex, and right posterior temporal cortex. Our results indicate that alterations in rCBF in patients with PHP can be demonstrated with brain SPECT. The correlation between serum calcium, PTH levels and the sum of hypoperfused regions indicates that there may be a strong relationship between rCBF abnormalities and increased levels of serum calcium and PTH. In addition, the degree of rCBF abnormalities could be determined by brain SPECT in PHP patients with or without psychiatric symptoms. (orig.)

  15. Stroke Unit: General principles and standards

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-04-01

    Full Text Available Evidence-based medicinal methods have convincingly shown that stroke unit approach reduces mortality and disability rates, improves the quality of life and economic burden resulting from acute ischemic and hemorrhagic stroke. Any contemporary stroke system of care cannot be successful without putting the stroke unit concept in the center of its organization. Stroke units are the main elements of primary and comprehensive stroke centers. As a modernization process, this article focuses on practical issues and suggestions related to integration of the stroke unit approach to a regionally organized stroke system of care for perusal by not only national health authorities and service providers, but also neurologists. Stroke unit quality metrics revisited herein are of critical importance for hospitals establishing or renovating primary and comprehensive stroke centers.

  16. Morphometric differences in debris flow and mixed flow fans in eastern Death Valley, CA

    Science.gov (United States)

    Wasklewicz, T. A.; Whitworth, J.

    2004-12-01

    lengths of the channel and interfluve couplets and the percent pixels per unit area have been identified between the two fan groups. In general, shorter distances were found in the mixed flow fans. This finding can be attributed to primary and secondary erosional processes leading to a higher degree of dissection in the MF fan surfaces than was identified in the DF fans. The clast-rich deposits of the DF fan are more resistant to secondary erosional processes and overtopping of the levees likely leads to filling of older incised debris flow channels.

  17. Effects of Chaos in Peristaltic Flows: Towards Biological Applications

    Science.gov (United States)

    Wakeley, Paul W.; Blake, John R.; Smith, David J.; Gaffney, Eamonn A.

    2006-11-01

    One in seven couples in the Western World will have problems conceiving naturally and with the cost of state provided fertility treatment in the United Kingdom being over USD 3Million per annum and a round of treatment paid for privately costing around USD 6000, the desire to understand the mechanisms of infertility is leading to a renewed interest in collaborations between mathematicians and reproductive biologists. Hydrosalpinx is a condition in which the oviduct becomes blocked, fluid filled and dilated. Many women with this condition are infertile and the primary method of treatment is in vitro fertilisation, however, it is found that despite the embryo being implanted into the uterus, the hydrosalpinx adversely affects the implantation rate. We shall consider a mathematical model for peristaltic flow with an emphasis towards modelling the fluid flow in the oviducts and the uterus of humans. We shall consider the effects of chaotic behavior on the system and demonstrate that under certain initial conditions trapping regions can be formed and discuss our results with a view towards understanding the effects of hydrosalpinx.

  18. Estimation on the Pressure Loss of the Conceptual Primary Cooling System and Design of the Primary Cooling Pump for a Research Reactor

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Oh, Jae Min; Park, Jong Hark; Chae, Hee Taek; Seo, Jae Kwang; Park, Cheon Tae; Yoon, Ju Hyeon; Lee, Doo Jeong

    2009-01-01

    A new conceptual primary cooling system (PCS) for a research reactor has been designed for an adequate cooling to the reactor core which has various powers ranging from 30MW through 80MW. The developed primary cooling system consisted of decay tanks, pumps, heat exchangers, vacuum breakers, some isolation and check valves, connection piping, and instruments. Because the system flow rate should be determined by the thermal hydraulic design analysis for the core, the heads to design the primary cooling pumps (PCPs) in a PCS will be estimated by the variable system flow rates. The heads of the part of a research reactor vessel was evaluated by the previous study. The various pressure losses of the PCS can be calculated by the dimensional analysis of the pipe flow and the head loss coefficient of the components. The purpose of this research is to estimate the various pressure losses and to design the PCPs

  19. A primary standard for the calibration of sniffer test leak devices

    Science.gov (United States)

    Jousten, Karl; Becker, Ute

    2009-10-01

    Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.

  20. The impact of ethics and work-related factors on nurse practitioners' and physician assistants' views on quality of primary healthcare in the United States.

    Science.gov (United States)

    Ulrich, Connie M; Zhou, Qiuping Pearl; Hanlon, Alexandra; Danis, Marion; Grady, Christine

    2014-08-01

    Nurse practitioners (NPs) and physician assistants (PAs) provide primary care services for many American patients. Ethical knowledge is foundational to resolving challenging practice issues, yet little is known about the importance of ethics and work-related factors in the delivery of quality care. The aim of this study was to quantitatively assess whether the quality of the care that practitioners deliver is influenced by ethics and work-related factors. This paper is a secondary data analysis of a cross-sectional self-administered mailed survey of 1,371 primary care NPs and PAs randomly selected from primary care and primary care subspecialties in the United States. Ethics preparedness and confidence were significantly associated with perceived quality of care (pfactors. Investing in ethics education and addressing restrictive practice environments may improve collaborative practice, teamwork, and quality of care. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Vortical flows

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jie-Zhi [Peking Univ., Beijing (China). College of Engineering; Ma, Hui-Yang [Univ. of Chinese Academy of Sciences, Beijing (China). Dept. of Physics; Zhou, Ming-De [Arizona Univ., Tucson, AZ (United States). Dept. of Aerospace and Mechanical Engineering

    2015-11-01

    This book is a comprehensive and intensive book for graduate students in fluid dynamics as well as scientists, engineers and applied mathematicians. Offering a systematic introduction to the physical theory of vortical flows at graduate level, it considers the theory of vortical flows as a branch of fluid dynamics focusing on shearing process in fluid motion, measured by vorticity. It studies vortical flows according to their natural evolution stages,from being generated to dissipated. As preparation, the first three chapters of the book provide background knowledge for entering vortical flows. The rest of the book deals with vortices and vortical flows, following their natural evolution stages. Of various vortices the primary form is layer-like vortices or shear layers, and secondary but stronger form is axial vortices mainly formed by the rolling up of shear layers. Problems are given at the end of each chapter and Appendix, some for helping understanding the basic theories, and some involving specific applications; but the emphasis of both is always on physical thinking.

  2. Vortical flows

    International Nuclear Information System (INIS)

    Wu, Jie-Zhi; Ma, Hui-Yang; Zhou, Ming-De

    2015-01-01

    This book is a comprehensive and intensive book for graduate students in fluid dynamics as well as scientists, engineers and applied mathematicians. Offering a systematic introduction to the physical theory of vortical flows at graduate level, it considers the theory of vortical flows as a branch of fluid dynamics focusing on shearing process in fluid motion, measured by vorticity. It studies vortical flows according to their natural evolution stages,from being generated to dissipated. As preparation, the first three chapters of the book provide background knowledge for entering vortical flows. The rest of the book deals with vortices and vortical flows, following their natural evolution stages. Of various vortices the primary form is layer-like vortices or shear layers, and secondary but stronger form is axial vortices mainly formed by the rolling up of shear layers. Problems are given at the end of each chapter and Appendix, some for helping understanding the basic theories, and some involving specific applications; but the emphasis of both is always on physical thinking.

  3. Flow-induced vibration analysis of Three Mile Island Unit-2 once-through steam generator tubes. Volume 1. Final report

    International Nuclear Information System (INIS)

    Johnson, J.R.; Brown, J.C.; Harris, C.E.; McGuinn, E.J.; Simonis, J.C.; Thoren, D.E.

    1981-06-01

    Tube responses to flow-induced vibration were measured in the top two spans and the tenth span in the B once-through steam generator at Three Mile Island, Unit 2. This program evaluated the effects of flow-induced biration of OTSG tubes during steady-state and transient operation. Twenty-three tubes were instrumented with accelerometers and strain gages in tubes located along the open lane, in the bundle, and at the tenth span. Tube displacements, frequencies, dynamic strains, and mode shapes were determined during steady-state and transient operation. Pressure sensors were installed in the OTSG to measure pressure fluctuations and plant parameters, which were recorded for correlation with tube response. Data analysis results indicate that the steady-state tube response increases with increasing reactor power, with the maximum response (12 mils peak to peak at midspan) at the outer perimeter of the generator in the 16th span

  4. Geochemical and Isotopic Interpretations of Groundwater Flow in the Oasis Valley Flow System, Southern Nevada

    International Nuclear Information System (INIS)

    Thomas, J.M.; Benedict, F.C. Jr.; Rose, T.P.; Hershey, R.L.; Paces, J.B.; Peterman, Z.E.; Farnham, I.M.; Johannesson, K.H.; Singh, A.K.; Stetzenbach, K.J.; Hudson, G.B.; Kenneally, J.M.; Eaton, G.F.; Smith, D.K.

    2003-01-01

    This report summarizes the findings of a geochemical investigation of the Pahute Mesa-Oasis Valley groundwater flow system in southwestern Nevada. It is intended to provide geochemical data and interpretations in support of flow and contaminant transport modeling for the Western and Central Pahute Mesa Corrective Action Units

  5. Toward a Unified Integration Approach: Uniting Diverse Primary Care Strategies Under the Primary Care Behavioral Health (PCBH) Model.

    Science.gov (United States)

    Sandoval, Brian E; Bell, Jennifer; Khatri, Parinda; Robinson, Patricia J

    2017-12-12

    Primary care continues to be at the center of health care transformation. The Primary Care Behavioral Health (PCBH) model of service delivery includes patient-centered care delivery strategies that can improve clinical outcomes, cost, and patient and primary care provider satisfaction with services. This article reviews the link between the PCBH model of service delivery and health care services quality improvement, and provides guidance for initiating PCBH model clinical pathways for patients facing depression, chronic pain, alcohol misuse, obesity, insomnia, and social barriers to health.

  6. Lacustrine-humate model for primary uranium ore deposits, Grants Uranium Region, New Mexico

    International Nuclear Information System (INIS)

    Turner-Peterson, C.E.

    1985-01-01

    Two generations of uranium ore, primary and redistributed, occur in fluvial sandstones of the Upper Jurassic Morrison Formation in the San Juan basin; the two stages of ore formation can be related to the hydrologic history of the basin. Primary ore formed soon after Morrison deposition, in the Late Jurassic to Early Cretaceous, and a model, the lacustrine-humate model, is offered that views primary mineralization as a diagenetic event related to early pore fluid evolution. The basic premise is that the humate, a pore-filling organic material closely associated with primary ore, originated as humic acids dissolved in pore waters of greenish-gray lacustrine mudstones deposited in the mud-flat facies of the Brushy Basin Member and similar K shale beds in the Westwater Canyon Member. During compaction associated with early burial, formation water expelled from lacustrine mudstone units carried these humic acids into adjacent sandstone beds where the organics precipitated, forming the humate deposits that concentrated uranium. During the Tertiary, much later in the hydrologic history of the basin, when Jurassic sediments were largely compacted, oxygenated ground water flowed basinward from uplifted basin margins. This invasion of Morrison sandstone beds by oxidizing ground waters redistributed uranium from primary ores along redox boundaries, forming ore deposits that resemble roll-front-type uranium ores. 11 figures

  7. Ratiometric analysis of fura red by flow cytometry: a technique for monitoring intracellular calcium flux in primary cell subsets.

    Directory of Open Access Journals (Sweden)

    Emily R Wendt

    Full Text Available Calcium flux is a rapid and sensitive measure of cell activation whose utility could be enhanced with better techniques for data extraction. We describe a technique to monitor calcium flux by flow cytometry, measuring Fura Red calcium dye by ratiometric analysis. This technique has several advantages: 1 using a single calcium dye provides an additional channel for surface marker characterization, 2 allows robust detection of calcium flux by minority cell populations within a heterogeneous population of primary T cells and monocytes 3 can measure total calcium flux and additionally, the proportion of responding cells, 4 can be applied to studying the effects of drug treatment, simultaneously stimulating and monitoring untreated and drug treated cells. Using chemokine receptor activation as an example, we highlight the utility of this assay, demonstrating that only cells expressing a specific chemokine receptor are activated by cognate chemokine ligand. Furthermore, we describe a technique for simultaneously stimulating and monitoring calcium flux in vehicle and drug treated cells, demonstrating the effects of the Gαi inhibitor, pertussis toxin (PTX, on chemokine stimulated calcium flux. The described real time calcium flux assay provides a robust platform for characterizing cell activation within primary cells, and offers a more accurate technique for studying the effect of drug treatment on receptor activation in a heterogeneous population of primary cells.

  8. experimental investigation of flow pattern around repelling

    African Journals Online (AJOL)

    A. Mahdieh NajafAbadi and M. M. Bateni

    2017-09-01

    Sep 1, 2017 ... FLOW-3D® software used to simulate flow pattern. The simulation was .... separated into separation zone, shear layer, vortices zone, end point of vorticity zone and primary flow zone. In the figure, b1 and b2 denote ... closer to the wall for the attractive spur dike. For case of the repelling spur dike, transverse.

  9. Investigation for vertical, two-phase steam-water flow of three turbine models

    International Nuclear Information System (INIS)

    Silverman, S.; Goodrich, L.D.

    1977-01-01

    One of the basic quantities of interest during a loss-of-coolant experiment (LOCE) is the primary system mass flow rate. Presently, there are no transducers commercially available which continuously measure this parameter. Therefore, a transducer was designed at EG and G Idaho, Inc. which combines a drag-disc and turbine into a single unit. The basis for the design was that the drag-disc would measure momentum flux (rhoV 2 ), the turbine would measure velocity and the mass flow rate could then be calculated from the two quantities by assuming a flow profile. For two-phase flow, the outputs are approximately proportional to the desired parameter, but rather large errors can be expected under those assumptions. Preliminary evaluation of the experimental two- and single-phase calibration data has resulted in uncertainty estimates of +-8% of range for the turbine and +-20% of range for the drag-disc. In an effort to reduce the errors, further investigations were made to determine what the drag-disc and turbine really measure. In the present paper, three turbine models for vertical, two-phase, steam/water flow are investigated; the Aya Model, the Rouhani Model, and a volumetric flow model. Theoretical predictions are compared with experimental data for vertical, two-phase steam/water flow. For the purposes of the mass flow calculation, velocity profiles were assumed to be flat for the free-field condition. It is appreciated that this may not be true for all cases investigated, but for an initial inspection, flat profiles were assumed

  10. Erosion in extruder flow

    Science.gov (United States)

    Kaufman, Miron; Fodor, Petru S.

    A detailed analysis of the fluid flow in Tadmor's unwound channel model of the single screw extruder is performed by combining numerical and analytical methods. Using the analytical solution for the longitudinal velocity field (in the limit of zero Reynolds number) allows us to devote all the computational resources solely for a detailed numerical solution of the transversal velocity field. This high resolution 3D model of the fluid flow in a single-screw extruder allows us to identify the position and extent of Moffatt eddies that impede mixing. We further consider the erosion of particles (e.g. carbon-black agglomerates) advected by the polymeric flow. We assume a particle to be made of primary fragments bound together. In the erosion process a primary fragment breaks out of a given particle. Particles are advected by the laminar flow and they disperse because of the shear stresses imparted by the fluid. The time evolution of the numbers of particles of different sizes is described by the Bateman coupled differential equations used to model radioactivity. Using the particle size distribution we compute an entropic fragmentation index which varies from 0 for a monodisperse system to 1 for an extreme poly-disperse system.

  11. Hydrologic Data for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Drici, Warda [Stoller-Navarro Joint Venture, Las Vegas, NV (United States)

    2004-02-01

    This report documents the analysis of the available hydrologic data conducted in support of the development of a Corrective Action Unit (CAU) groundwater flow model for Central and Western Pahute Mesa: CAUs 101 and 102.

  12. Primary contention 12RU1 radiological control

    International Nuclear Information System (INIS)

    Padilla C, I.

    2007-01-01

    In the primary contention of the Laguna Verde central reactors those are located the main components and control and safety systems related directly with the reactor vessel. Space, accesses, location, maneuvers, armor-plating, movements of components and radiological conditions require of a constant attention to maintain the control of the activities during a fuel reload period. Knowledge, analysis, strategies and attention to the detail in the preparation stages and execution of the fuel reload are fundamental to sum up the objectives. The reload stop 12 of the Unit 1, it required a specific attention in the radiation source due to the addition of noble metals and hydrogen to the vessel internals that generated an increment in the soluble elements of Cobalt and that it was reflected in the radiation fields in the primary contention. Movement of armor-plating of the structures of the biological armor-plating demand to establish new strategies in the control of activities for the next fuel reloads. The analysis and control of the relief valves safety of the reactor vessel, of the exchange of the activation mechanisms of the control bars, as well as of the isolation valves of main vapor and of flow control valves of the reactor recirculation system, its required of a particular attention due to their particular radiological environment, in a brief time space. The importance of this work is located in the detail of critical activities to fulfill the established goals, with successes that can be optimized, and improvement areas that require of investigation and analysis for the implementation of new technologies tend toward to the dose optimization. The reload stop 12 of the unit 1 conclude with 2.43 Sv-person in a period of 27.5 days. (Author)

  13. Experimental study of turbulent flows through pipe bends

    OpenAIRE

    Kalpakli, Athanasia

    2012-01-01

    This thesis deals with turbulent flows in 90 degree curved pipes of circular cross-section. The flow cases investigated experimentally are turbulent flow with and without an additional motion, swirling or pulsating, superposed on the primary flow. The aim is to investigate these complex flows in detail both in terms of statistical quantities as well as vortical structures that are apparent when curvature is present. Such a flow field can contain strong secondary flow in a plane normal to the ...

  14. 50 CFR 14.151 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING... Wild Mammals and Birds to the United States Specifications for Sloths, Bats, and Flying Lemurs... located on the upper one-half of the primary enclosure. (b) No more than one sloth, bat, or flying lemur...

  15. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  16. Optical Sensor of Thermal Gas Flow Based on Fiber Bragg Grating

    Directory of Open Access Journals (Sweden)

    Xu Jiang

    2017-02-01

    Full Text Available This paper aims at solving the problem of explosion proof in measurement of thermal gas flow using electronic sensor by presenting a new type of flow sensor by optical fiber heating. A measuring unit based on fiber Bragg grating (FBG for fluid temperature and a unit for heat dissipation are designed to replace the traditional electronic sensors. The light in C band from the amplified spontaneous emission (ASE light source is split, with one part used to heat the absorbing coating and the other part used in the signal processing unit. In the heating unit, an absorbing coating is introduced to replace the traditional resistance heating module to minimize the risk of explosion. The measurement results demonstrate a fine consistency between the flow and temperature difference in simulation. The method to enhance the measurement resolution of flow is also discussed.

  17. Design Guideline for Primary Heat Exchanger in a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sunil; Seo, Kyoung-Woo; Kim, Seong-Hoon; Chi, Dae-Young; Park, Cheol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this paper, analytical study is conducted to track the variation of the PCS outlet temperature in conditions of the constant core power and constant SCS inlet temperature. The PCS circulates demineralized water to remove the heat generated in reactor core. The heat is transferred to the cold water of the SCS through the primary heat exchanger. In JRTR, Plate-type Heat Exchanger (PHE) was used as the primary heat exchanger. The cooling tower automatically sets the SCS inlet temperature constant by fan speed control. The flow rate of SCS is adjusted to be identical with the PCS flow rate. To design the PHE, the inlet and outlet temperatures and the flow rates for both systems should be determined. The flow rate has the allowable band for the safe operation from the lower limit to upper limit resulting in different temperature distribution in the PHE. Specially, the PCS outlet temperature which is the core inlet temperature is used for a safety parameter for the reactor shutdown. Therefore, we need to figure out which limit for the flow rate should be used from the conservative point of view. At 200 kg/s of PCS and SCS flow rates, the inlet and outlet temperatures are 41.3℃and 34℃, respectively. With increase of the flow rate, both of PCS inlet and outlet temperatures decrease to 33.6℃ and 39.9℃. This result means the low limit of the allowable flow band should be used for the conservative design of primary heat exchanger. If the upper limit of the allowable flow band is used, the PCS outlet temperature which is the safety parameter used for the reactor shutdown increases with decrease of the flow rate.

  18. Design Guideline for Primary Heat Exchanger in a Research Reactor

    International Nuclear Information System (INIS)

    Lee, Sunil; Seo, Kyoung-Woo; Kim, Seong-Hoon; Chi, Dae-Young; Park, Cheol

    2016-01-01

    In this paper, analytical study is conducted to track the variation of the PCS outlet temperature in conditions of the constant core power and constant SCS inlet temperature. The PCS circulates demineralized water to remove the heat generated in reactor core. The heat is transferred to the cold water of the SCS through the primary heat exchanger. In JRTR, Plate-type Heat Exchanger (PHE) was used as the primary heat exchanger. The cooling tower automatically sets the SCS inlet temperature constant by fan speed control. The flow rate of SCS is adjusted to be identical with the PCS flow rate. To design the PHE, the inlet and outlet temperatures and the flow rates for both systems should be determined. The flow rate has the allowable band for the safe operation from the lower limit to upper limit resulting in different temperature distribution in the PHE. Specially, the PCS outlet temperature which is the core inlet temperature is used for a safety parameter for the reactor shutdown. Therefore, we need to figure out which limit for the flow rate should be used from the conservative point of view. At 200 kg/s of PCS and SCS flow rates, the inlet and outlet temperatures are 41.3℃and 34℃, respectively. With increase of the flow rate, both of PCS inlet and outlet temperatures decrease to 33.6℃ and 39.9℃. This result means the low limit of the allowable flow band should be used for the conservative design of primary heat exchanger. If the upper limit of the allowable flow band is used, the PCS outlet temperature which is the safety parameter used for the reactor shutdown increases with decrease of the flow rate

  19. Measurement and Characterization of Apoptosis by Flow Cytometry.

    Science.gov (United States)

    Telford, William; Tamul, Karen; Bradford, Jolene

    2016-07-01

    Apoptosis is an important mechanism in cell biology, playing a critical regulatory role in virtually every organ system. It has been particularly well characterized in the immune system, with roles ranging from immature immune cell development and selection to down-regulation of the mature immune response. Apoptosis is also the primary mechanism of action of anti-cancer drugs. Flow cytometry has been the method of choice for analyzing apoptosis in suspension cells for more than 25 years. Numerous assays have been devised to measure both the earliest and latest steps in the apoptotic process, from the earliest signal-transduction events to the late morphological changes in cell shape and granularity, proteolysis, and chromatin condensation. These assays are particularly powerful when combined into multicolor assays determining several apoptotic characteristics simultaneously. The multiparametric nature of flow cytometry makes this technology particularly suited to measuring apoptosis. In this unit, we will describe the four main techniques for analyzing caspase activity in apoptotic cells, combined with annexin V and cell permeability analysis. These relatively simple multiparametric assays are powerful techniques for assessing cell death. © 2016 by John Wiley & Sons, Inc. Copyright © 2016 John Wiley & Sons, Inc.

  20. Numerical Analysis of Flow Distribution in a Sodium Chamber of a Finned-tube Sodium-to-Air Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Youngchul; Son, Seokkwon; Kim, Hyungmo; Eoh, Jaehyuk; Jeong, Jiyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    DHR systems consist of two diverse heat removal loops such as passive and active DHR systems, and the heat load imposed on the primary sodium pool is safely rejected into the environment through different kinds of sodium-to-air heat exchangers, e.g. M-shape and helical-coil type air-coolers. The former is called as an FHX(Forced-draft sodium-to-air Heat Exchanger) and the latter is simply called as an AHX(natural-draft sodium-to-Air Heat Exchanger). In a general sodium-to-air heat exchanger design, convection resistance in a shell-side air flow path becomes dominant factor affecting the mechanism of conjugate heat transfer from the sodium flow inside the tube to the air path across the sodium tube wall. Hence verification of the flow and heat transfer characteristics is one of the most important tasks to demonstrate decay heat removal performance. To confirm a kind of ultimate heat sink heat exchanger, a medium-scale Sodium thermal-hydraulic Experiment Loop for Finned-tube sodium-to-Air Heat exchanger (here after called the SELFA) has been designed and is recently being constructed at KAERI site. The introduction of the flow baffle inside the upper sodium chamber of the model FHX unit in the SELFA facility is briefly proposed and discussed as well. The present study aims at introducing a flow baffle design inside the upper sodium chamber to make more equalized flowrates flowing into each heat transfer tube of the model FHX unit. In the cases without the flow baffle geometry, it was observed lager discrepancies in flowrates at the heat transfer tubes. However it was also found that those kinds of discrepancies could be definitely decreased at around 1/10 by employing a flow baffle.

  1. Primary and secondary battery consumption trends in Sweden 1996–2013: Method development and detailed accounting by battery type

    International Nuclear Information System (INIS)

    Patrício, João; Kalmykova, Yuliya; Berg, Per E.O.; Rosado, Leonardo; Åberg, Helena

    2015-01-01

    Highlights: • Developed MFA method was validated by the national statistics. • Exponential increase of EEE sales leads to increase in integrated battery consumption. • Digital convergence is likely to be a cause for primary batteries consumption decline. • Factors for estimation of integrated batteries in EE are provided. • Sweden reached the collection rates defined by European Union. - Abstract: In this article, a new method based on Material Flow Accounting is proposed to study detailed material flows in battery consumption that can be replicated for other countries. The method uses regularly available statistics on import, industrial production and export of batteries and battery-containing electric and electronic equipment (EEE). To promote method use by other scholars with no access to such data, several empirically results and their trends over time, for different types of batteries occurrence among the EEE types are provided. The information provided by the method can be used to: identify drivers of battery consumption; study the dynamic behavior of battery flows – due to technology development, policies, consumers behavior and infrastructures. The method is exemplified by the study of battery flows in Sweden for years 1996–2013. The batteries were accounted, both in units and weight, as primary and secondary batteries; loose and integrated; by electrochemical composition and share of battery use between different types of EEE. Results show that, despite a fivefold increase in the consumption of rechargeable batteries, they account for only about 14% of total use of portable batteries. Recent increase in digital convergence has resulted in a sharp decline in the consumption of primary batteries, which has now stabilized at a fairly low level. Conversely, the consumption of integrated batteries has increased sharply. In 2013, 61% of the total weight of batteries sold in Sweden was collected, and for the particular case of alkaline manganese

  2. Primary and secondary battery consumption trends in Sweden 1996–2013: Method development and detailed accounting by battery type

    Energy Technology Data Exchange (ETDEWEB)

    Patrício, João, E-mail: joao.patricio@chalmers.se [Department of Civil and Environmental Engineering, Chalmers University of Technology, 412 96 Gothenburg (Sweden); Kalmykova, Yuliya; Berg, Per E.O.; Rosado, Leonardo [Department of Civil and Environmental Engineering, Chalmers University of Technology, 412 96 Gothenburg (Sweden); Åberg, Helena [The Faculty of Education, University of Gothenburg, 40530 Gothenburg (Sweden)

    2015-05-15

    Highlights: • Developed MFA method was validated by the national statistics. • Exponential increase of EEE sales leads to increase in integrated battery consumption. • Digital convergence is likely to be a cause for primary batteries consumption decline. • Factors for estimation of integrated batteries in EE are provided. • Sweden reached the collection rates defined by European Union. - Abstract: In this article, a new method based on Material Flow Accounting is proposed to study detailed material flows in battery consumption that can be replicated for other countries. The method uses regularly available statistics on import, industrial production and export of batteries and battery-containing electric and electronic equipment (EEE). To promote method use by other scholars with no access to such data, several empirically results and their trends over time, for different types of batteries occurrence among the EEE types are provided. The information provided by the method can be used to: identify drivers of battery consumption; study the dynamic behavior of battery flows – due to technology development, policies, consumers behavior and infrastructures. The method is exemplified by the study of battery flows in Sweden for years 1996–2013. The batteries were accounted, both in units and weight, as primary and secondary batteries; loose and integrated; by electrochemical composition and share of battery use between different types of EEE. Results show that, despite a fivefold increase in the consumption of rechargeable batteries, they account for only about 14% of total use of portable batteries. Recent increase in digital convergence has resulted in a sharp decline in the consumption of primary batteries, which has now stabilized at a fairly low level. Conversely, the consumption of integrated batteries has increased sharply. In 2013, 61% of the total weight of batteries sold in Sweden was collected, and for the particular case of alkaline manganese

  3. Investigations on flow reversal in stratified horizontal flow

    International Nuclear Information System (INIS)

    Staebler, T.; Meyer, L.; Schulenberg, T.; Laurien, E.

    2005-01-01

    The phenomena of flow reversal in stratified flows are investigated in a horizontal channel with application to the Emergency Core Cooling System (ECCS) in Pressurized Water Reactors (PWR). In case of a Loss-of-Coolant-Accident (LOCA), coolant can be injected through a secondary pipe within the feeding line of the primary circuit, the so called hot leg, counter-currently to the steam flow. It is essential that the coolant reaches the reactor core to prevent overheating. Due to high temperatures in such accident scenarios, steam is generated in the core, which escapes from the reactor vessel through the hot leg. In case of sufficiently high steam flow rates, only a reduced amount of coolant or even no coolant will be delivered to the reactor core. The WENKA test facility at the Institute for Nuclear and Energy Technologies (IKET) at Forschungszentrum Karlsruhe is capable to investigate the fluid dynamics of two-phase flows in such scenarios. Water and air flow counter-currently in a horizontal channel made of clear acrylic glass to allow full optical access. Flow rates of water and air can be varied independently within a wide range. Once flow reversal sets in, a strong hysteresis effect must be taken into account. This was quantified during the present investigations. Local experimental data are needed to expand appropriate models on flow reversal in horizontal two-phase flow and to include them into numerical codes. Investigations are carried out by means of Particle Image Velocimetry (PIV) to obtain local flow velocities without disturbing the flow. Due to the wavy character of the flow, strong reflections at the interfacial area must be taken into account. Using fluorescent particles and an optical filter allows eliminating the reflections and recording only the signals of the particles. The challenges in conducting local investigations in stratified wavy flows by applying optical measurement techniques are discussed. Results are presented and discussed allowing

  4. The flow of goods model of the Rotterdam Port Authority; Het goederenstromenmodel voor de Rotterdamse haven. De verhouding tussen fysieke stromen en economische grootheden

    Energy Technology Data Exchange (ETDEWEB)

    Saitua, R. [Haveninnovatie van het Gemeentelijk Havenbedrijf, Rotterdam (Netherlands)

    1995-12-01

    Long term forecasts of the flow of goods through the Port of Rotterdam are essential for port development aims and to quantify the environmental effects of the generated traffic. Experience of the Rotterdam Port Authority shows that the differences between forecasts and realization can be explained by radical changes in the trends as a consequence of technological and social developments. In the `Flow of goods model number 6` scenario, techniques have been used to asses the fundamental uncertainty of the future, as well as a combination of quantitative and qualitative methods (for example expert judgements). Much attention has been given to the so called `dematerialization` trend, which means less use of primary commodities by production unit. Problems that have to be tackled within a more appropriate way are: (1) expected less growth of the trade measured in weight than the trade measured in monetary units; and (2) the influence of geographical patterns of production (lean production with global sourcing versus more local diffused production) on trade and transport flows. 2 tabs., 9 refs.

  5. Impact of Shutting Down En Route Primary Radars within CONUS Interior

    Science.gov (United States)

    1993-06-01

    Remote Control Interface Unit ( RCIU ) RMS software for the primary radar will be deleted. Any dependency of the secondary radar on the primary radar data...Generators RCIU Remote Control and Interface Unit RMM Remote Monitoring and Maintenance RMMS Remote Maintenance Monitoring System RMS Remote Maintenance

  6. Water Use in the United States Energy System: A National Assessment and Unit Process Inventory of Water Consumption and Withdrawals.

    Science.gov (United States)

    Grubert, Emily; Sanders, Kelly T

    2018-06-05

    The United States (US) energy system is a large water user, but the nature of that use is poorly understood. To support resource comanagement and fill this noted gap in the literature, this work presents detailed estimates for US-based water consumption and withdrawals for the US energy system as of 2014, including both intensity values and the first known estimate of total water consumption and withdrawal by the US energy system. We address 126 unit processes, many of which are new additions to the literature, differentiated among 17 fuel cycles, five life cycle stages, three water source categories, and four levels of water quality. Overall coverage is about 99% of commercially traded US primary energy consumption with detailed energy flows by unit process. Energy-related water consumption, or water removed from its source and not directly returned, accounts for about 10% of both total and freshwater US water consumption. Major consumers include biofuels (via irrigation), oil (via deep well injection, usually of nonfreshwater), and hydropower (via evaporation and seepage). The US energy system also accounts for about 40% of both total and freshwater US water withdrawals, i.e., water removed from its source regardless of fate. About 70% of withdrawals are associated with the once-through cooling systems of approximately 300 steam cycle power plants that produce about 25% of US electricity.

  7. Measurement of flow in supercritical flow regime using cutthroat flumes

    Indian Academy of Sciences (India)

    flumes are used to measure flow rates in irrigation chan- nels and water treatment ... and ha can be expressed in unit system, the values of C and N in Eq. (1) will ... presented in a design chart for determining discharge in throat-less flume ...

  8. Modeling heterogeneous unsaturated porous media flow at Yucca Mountain

    International Nuclear Information System (INIS)

    Robey, T.H.

    1994-01-01

    Geologic systems are inherently heterogeneous and this heterogeneity can have a significant impact on unsaturated flow through porous media. Most previous efforts to model groundwater flow through Yucca Mountain have used stratigraphic units with homogeneous properties. However, modeling heterogeneous porous and fractured tuff in a more realistic manner requires numerical methods for generating heterogeneous simulations of the media, scaling of material properties from core scale to computational scale, and flow modeling that allows channeling. The Yucca Mountain test case of the INTRAVAL project is used to test the numerical approaches. Geostatistics is used to generate more realistic representations of the stratigraphic units and heterogeneity within units is generated using sampling from property distributions. Scaling problems are reduced using an adaptive grid that minimizes heterogeneity within each flow element. A flow code based on the dual mixed-finite-element method that allows for heterogeneity and channeling is employed. In the Yucca Mountain test case, the simulated volumetric water contents matched the measured values at drill hole USW UZ-16 except in the nonwelded portion of Prow Pass

  9. Transition from steady to periodic liquid-metal magnetohydrodynamic flow in a sliding electrical contact

    Science.gov (United States)

    Talmage, Gita; Walker, John S.; Brown, Samuel H.; Sondergaard, Neal A.

    1993-09-01

    In homopolar motors and generators, large dc electric currents pass through the sliding electrical contacts between rotating copper disks (rotors) and static copper surfaces shrouding the rotor tips (stators). A liquid metal in the small radial gap between the rotor tip and concentric stator surface can provide a low-resistance, low-drag electrical contact. Since there is a strong magnetic field in the region of the electrical contacts, there are large electromagnetic body forces on the liquid metal. The primary, azimuthal motion consists of simple Couette flow, plus an electromagnetically driven flow with large extremes of the azimuthal velocity near the rotor corners. The secondary flow involves the radial and axial velocity components, is driven by the centrifugal force associated with the primary flow, and is opposed by the electromagnetic body force, so that the circulation varies inversely as the square of the magnetic-field strength. Three flow regimes are identified as the angular velocity Ω of the rotor is increased. For small Ω, the primary flow is decoupled from the secondary flow. As Ω increases, the secondary flow begins to convect the azimuthal-velocity peaks radially outward, which in turn changes the centrifugal force driving the secondary flow. At some critical value of Ω, the flow becomes periodic through the coupling of the primary and secondary flows. The azimuthal-velocity peaks begin to move radially in and out with an accompanying oscillation in the secondary-flow strength.

  10. Rancang Bangun Perangkat Lunak Unit Kontrol Alat Ukur Sudu Cross Flow Water Turbine Berbasis Pengolahan Citra

    Directory of Open Access Journals (Sweden)

    Eka Marliana

    2014-09-01

    Full Text Available Seiring dengan berkembangnya teknologi informasi dan komunikasi, alat ukur mengalami perkembangan yang cukup signifikan. Salah satu bentuk perkembangannya adalah dengan dibuatnya alat ukur sudu cross flow water turbine berbasis pengolahan citra oleh Rusweki dan Pradnyana pada tahun 2013. Namun, alat ukur ini masih dioperasikan secara manual. Tugas akhir ini bertujuan untuk melakukan pengembangan terhadap alat tersebut, khususnya dibidang rancang bangun perangkat lunak untuk unit kontrolnya. Metodologi yang diterapkan dalam tugas akhir ini yang pertama adalah mempelajari hal-hal yang berkaitan dengan topik bahasan dari berbagai literatur. Langkah kedua adalah menetukan perumusan masalah dan menentukan metode pembuatan perangkat lunak. Ketiga, pembuatan perangkat lunak dan verifikasi. Pada penelitian ini telah berhasil dirancang perangkat lunak untuk unit kontrol alat ukur sudu CFWT berbasis pengolahan citra. Berdasarkan hasil kalibrasi sensor inframerah Sharp GP2Y0A21 didapatkan bahwa nilai jarak adalah sama dengan 178924.57 dibagi dengan nilai output ADC desimal pangkat 1.08. Selisih maksimal antara jarak input dan jarak tempuh motor adalah 0.5mm, dan jarak kontrol antara 130-400mm. Dengn demikian, metode pengukuran menggunakan alat ini akan lebih mudah dan cermat, karena selain dapat mengukur benda dengan bentuk yang kompleks mngurangi resiko keausan benda an lebih teliti, juga bisa diakukan dengan mudah serta cepat karena adanya sistem kontrol

  11. Primary and secondary battery consumption trends in Sweden 1996-2013: method development and detailed accounting by battery type.

    Science.gov (United States)

    Patrício, João; Kalmykova, Yuliya; Berg, Per E O; Rosado, Leonardo; Åberg, Helena

    2015-05-01

    In this article, a new method based on Material Flow Accounting is proposed to study detailed material flows in battery consumption that can be replicated for other countries. The method uses regularly available statistics on import, industrial production and export of batteries and battery-containing electric and electronic equipment (EEE). To promote method use by other scholars with no access to such data, several empirically results and their trends over time, for different types of batteries occurrence among the EEE types are provided. The information provided by the method can be used to: identify drivers of battery consumption; study the dynamic behavior of battery flows - due to technology development, policies, consumers behavior and infrastructures. The method is exemplified by the study of battery flows in Sweden for years 1996-2013. The batteries were accounted, both in units and weight, as primary and secondary batteries; loose and integrated; by electrochemical composition and share of battery use between different types of EEE. Results show that, despite a fivefold increase in the consumption of rechargeable batteries, they account for only about 14% of total use of portable batteries. Recent increase in digital convergence has resulted in a sharp decline in the consumption of primary batteries, which has now stabilized at a fairly low level. Conversely, the consumption of integrated batteries has increased sharply. In 2013, 61% of the total weight of batteries sold in Sweden was collected, and for the particular case of alkaline manganese dioxide batteries, the value achieved 74%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Estimating preferential flow in karstic aquifers using statistical mixed models.

    Science.gov (United States)

    Anaya, Angel A; Padilla, Ingrid; Macchiavelli, Raul; Vesper, Dorothy J; Meeker, John D; Alshawabkeh, Akram N

    2014-01-01

    Karst aquifers are highly productive groundwater systems often associated with conduit flow. These systems can be highly vulnerable to contamination, resulting in a high potential for contaminant exposure to humans and ecosystems. This work develops statistical models to spatially characterize flow and transport patterns in karstified limestone and determines the effect of aquifer flow rates on these patterns. A laboratory-scale Geo-HydroBed model is used to simulate flow and transport processes in a karstic limestone unit. The model consists of stainless steel tanks containing a karstified limestone block collected from a karst aquifer formation in northern Puerto Rico. Experimental work involves making a series of flow and tracer injections, while monitoring hydraulic and tracer response spatially and temporally. Statistical mixed models (SMMs) are applied to hydraulic data to determine likely pathways of preferential flow in the limestone units. The models indicate a highly heterogeneous system with dominant, flow-dependent preferential flow regions. Results indicate that regions of preferential flow tend to expand at higher groundwater flow rates, suggesting a greater volume of the system being flushed by flowing water at higher rates. Spatial and temporal distribution of tracer concentrations indicates the presence of conduit-like and diffuse flow transport in the system, supporting the notion of both combined transport mechanisms in the limestone unit. The temporal response of tracer concentrations at different locations in the model coincide with, and confirms the preferential flow distribution generated with the SMMs used in the study. © 2013, National Ground Water Association.

  13. Control Synthesis for the Flow-Based Microfluidic Large-Scale Integration Biochips

    DEFF Research Database (Denmark)

    Minhass, Wajid Hassan; Pop, Paul; Madsen, Jan

    2013-01-01

    In this paper we are interested in flow-based microfluidic biochips, which are able to integrate the necessary functions for biochemical analysis on-chip. In these chips, the flow of liquid is manipulated using integrated microvalves. By combining severalmicrovalves, more complex units, such asmi......In this paper we are interested in flow-based microfluidic biochips, which are able to integrate the necessary functions for biochemical analysis on-chip. In these chips, the flow of liquid is manipulated using integrated microvalves. By combining severalmicrovalves, more complex units...

  14. Do Offshore Wind Farms Influence Marine Primary Production?

    Science.gov (United States)

    Tweddle, J. F.; Murray, R. B. O.; Gubbins, M.; Scott, B. E.

    2016-02-01

    Primary producers (phytoplankton) form the basis of marine food-webs, supporting production of higher trophic levels, and act as a sink of CO2. We considered the impact of proposed large scale offshore wind farms in moderately deep waters (> 45 m) off the east coast of Scotland on rates of primary production. A 2 stage modelling process was used, employing state-of-the-art 3-D hydrographic models with the ability to capture flow at the spatial resolution of 10 m combined with 1-D vertical modelling using 7 years of local forcing data. Through influencing the strength of stratification via changes in current flow, large (100 m) modelled wind turbine foundations had a significant effect on primary producers, consistently reducing total annual primary production, although within the range of natural interannual variability. The percentage reduction was largest over submarine banks less than 54 m in depth, and was outside the range of natural interannual variability. Smaller (10 m) turbine foundations had no discernible effect on total annual primary production. The results indicate that smaller foundations should be favored as a mitigation measure, in terms of effects on primary production, and this type of analysis should be considered within sectoral planning and licensing processes for future renewable energy developments.

  15. Audit of a new model of birth care for women with low risk pregnancies in South Africa: the primary care onsite midwife-led birth unit (OMBU).

    Science.gov (United States)

    Hofmeyr, George Justus; Mancotywa, Thozeka; Silwana-Kwadjo, Nomvula; Mgudlwa, Batembu; Lawrie, Theresa A; Gülmezoglu, Ahmet Metin

    2014-12-20

    South Africa's health system is based on the primary care model in which low-risk maternity care is provided at community health centres and clinics, and 'high-risk' care is provided at secondary/tertiary hospitals. This model has the disadvantage of delays in the management of unexpected intrapartum complications in otherwise low-risk pregnancies, therefore, there is a need to re-evaluate the models of birth care in South Africa. To date, two primary care onsite midwife-led birth units (OMBUs) have been established in the Eastern Cape. OMBUs are similar to alongside midwifery units but have been adapted to the South African health system in that they are staffed, administered and funded by the primary care service. They allow women considered to be at 'low risk' to choose between birth in a community health centre and birth in the OMBU. The purpose of this audit was to evaluate the impact of establishing an OMBU at Frere Maternity Hospital in East London, South Africa, on maternity services. We conducted an audit of routinely collected data from Frere Maternity Hospital over two 12 month periods, before and after the OMBU opened. Retrospectively retrieved data included the number of births, maternal and perinatal deaths, and mode of delivery. After the OMBU opened at Frere Maternity Hospital, the total number of births on the hospital premises increased by 16%. The total number of births in the hospital obstetric unit (OU) dropped by 9.3%, with 1611 births out of 7375 (22%) occurring in the new OMBU. The number of maternal and perinatal deaths was lower in the post-OMBU period compared with the pre-OMBU period. These improvements cannot be assumed to be the result of the intervention as observational studies are prone to bias. The mortality data should be interpreted with caution as other factors such as change in risk profile may have contributed to the death reductions. There are many additional advantages for women, hospital staff and primary care staff with

  16. Investigation of transition scenarios in boundary-layer flows

    Energy Technology Data Exchange (ETDEWEB)

    Stolte, A.

    1999-11-01

    Laminar-turbulent transition mechanisms triggered by crossflow instability in three-dimensional, accelerated boundary-layer flows are investigated using numerical methods of stability analysis. The investigations are based on the DLR swept plate experiment, where stationary and traveling crossflow modes can be selectively introduced into the flow field. Nonlinear instability analyses employing the parabolized stability equations (PSE) show that unique saturation amplitudes do neither exist for stationary crossflow vortices nor for traveling crossflow waves. This phenomenon is explained by means of a spatial bifurcation model. Using Floquet theory, temporal secondary instability analyses are then performed for the mean flow distorted by primary disturbances. In these analyses, secondary high-frequency disturbances with high growth rates are found. The location of these disturbances correlates well with regions of high shear in the primarily distorted flow field, especially on the back of the primary crossflow vortices. (orig.)

  17. Parametric study of the primary and secondary systems of the CAREM-25 reactor on steady state

    International Nuclear Information System (INIS)

    Halpert, Silvia; Vazquez, Luis

    2000-01-01

    In the CAREM-25 reactor the primary coolant flows by natural convection that's why the flow is established when the balance between the buoyancy force and friction pressure drop through circuit is obtained. This paper presents a parametric study on primary and secondary systems of the reactor on steady state, for different values of some thermohydraulics parameters: safety factor on friction loss pressure calculations (f), steam generator heat transfer area (A T ) and primary pressure (P P ). The ESCAREM 2.08 thermohydraulic code, which calculates the primary system behavior for steady state conditions, was used for this study. The conclusions of this study are: -) There was a variation of the 15% on the primary coolant flow when the safety factor was changed a 50 %; -) The primary and secondary systems conditions do not change when the power is less than 100 MW; -) Between 100 and 110 MW the decrease of the heat transfer area produces an important change on the secondary systems conditions: the outlet steam generator temperature decrease and there is an important rice in the flow; -) The primary pressure could decrease up to 11.4 MPa without violating turbine requirements. (author)

  18. Low resource ventilation unit; Ressourcebesparende ventilationsenhed

    Energy Technology Data Exchange (ETDEWEB)

    Drivsholm, C.

    2012-03-15

    In the project a resource-saving ventilation device was developed which is based on the use of a regenerator and a reversible air flow. The regenerator is placed in the building envelope, and the concept works in the way that the heat in the air during ventilation is stored in the regenerator and brought back into the building by a reversible air change. The heated air is blown from inside the building out through the regenerator. In this way the regenerator accumulates the heat in the air. Over a period of 30-120 seconds, the regenerator capacity is utilized. When the regenerator cannot be further heated, the air flow is reversed and there is now blown cold air through the regenerator. Thereby the heat from the regenerator is released to the cold fresh air. Thus, the fresh air brings heat back into the building, whereby the air is replaced with a limited heat loss. Ventilation with a regenerator is described as micro-ventilation. The developed micro-ventilation unit was tested by the Danish Technological Institute. The test results shows that the unit performs according to expectations: 1) The heat recovery is 85%; 2) The flow through the unit is 80m3 per hour in a 5 section unit; 3) The noise level is 30 db(A) in a representative room; 4) The energy consumption is <300 J/m3. The unit is introduced into the market, and the first plants have been sold. (LN)

  19. Primary system thermal hydraulics of future Indian fast reactors

    Energy Technology Data Exchange (ETDEWEB)

    Velusamy, K., E-mail: kvelu@igcar.gov.in [Thermal Hydraulics Section, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Natesan, K.; Maity, Ram Kumar; Asokkumar, M.; Baskar, R. Arul; Rajendrakumar, M.; Sarathy, U. Partha; Selvaraj, P.; Chellapandi, P. [Thermal Hydraulics Section, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India); Kumar, G. Senthil; Jebaraj, C. [AU-FRG Centre for CAD/CAM, Anna University, Chennai 600 025 (India)

    2015-12-01

    Highlights: • We present innovative design options proposed for future Indian fast reactor. • These options have been validated by extensive CFD simulations. • Hotspot factors in fuel subassembly are predicted by parallel CFD simulations. • Significant safety improvement in the thermal hydraulic design is quantified. - Abstract: As a follow-up to PFBR (Indian prototype fast breeder reactor), many FBRs of 500 MWe capacity are planned. The focus of these future FBRs is improved economy and enhanced safety. They are envisaged to have a twin-unit concept. Design and construction experiences gained from PFBR project have provided motivation to achieve an optimized design for future FBRs with significant design changes for many critical components. Some of the design changes include, (i) provision of four primary pipes per primary sodium pump, (ii) inner vessel with single torus lower part, (iii) dome shape roof slab supported on reactor vault, (iv) machined thick plate rotating plugs, (v) reduced main vessel diameter with narrow-gap cooling baffles and (vi) safety vessel integrated with reactor vault. This paper covers thermal hydraulic design validation of the chosen options with respect to hot and cold pool thermal hydraulics, flow requirement for main vessel cooling, inner vessel temperature distribution, safety analysis of primary pipe rupture event, adequacy of decay heat removal capacity by natural convection cooling, cold pool transient thermal loads and thermal management of top shield and reactor vault.

  20. Modeling the Design Flow Coefficient of a Centrifugal Compressor Impeller

    Directory of Open Access Journals (Sweden)

    A. A. Drozdov

    2017-01-01

    Full Text Available In calculating gas-dynamic characteristics by the universal modeling method it is necessary to determine a non-incidence flow rate through the blades of an impeller because of its relationship with the magnitude of incidence losses. The flow area decreased by the blades of finite thickness and the blades load have impact on the critical streamline direction. The universal modeling method in primary designing uses for this a scheme of replacing the influence of the blade load by the vortex effect with identical circulation. Finally, calculating the inviscid flow around the blades allows selecting a value of the inlet blade angle. For impellers with small design flow coefficients, the condition of the non-incidence inlet for the primary design and for the calculation of the inviscid flow is significantly different. The calculating correctness of the non-incidence regime for the non-viscous flow was checked earlier by measurements of the flow in the impellers. The paper presents CFD calculations of twenty impellers in a tenfold range of design flow coefficients. To provide correct comparison, it takes into account the differences in the value of the loading factor calculated by the programs of inviscid quasi-three-dimensional calculation and CFD programs. Shows the identity of inlet conditions for both methods. To increase primary design accuracy, the calculation model was refined. The formula for calculating vortex-induced velocity involves an empirical coefficient. The analysis of data for 32 impellers with different blade profiling allowed working out formulas for calculating empirical coefficient, depending on the type of an impeller, the blade load and the width of the throat at an impeller inlet. The new scheme-based calculation with the empirical coefficient is accurate enough for the primary design.

  1. Contaminant Transport Parameters for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Drici, Warda [International Technologies Corporation, Las Vegas, NV (United States)

    2003-08-01

    This report documents the analysis of the available transport parameter data conducted in support of the development of a Corrective Action Unit (CAU) groundwater flow model for Central and Western Pahute Mesa: CAUs 101 and 102.

  2. A network-flow based valve-switching aware binding algorithm for flow-based microfluidic biochips

    DEFF Research Database (Denmark)

    Tseng, Kai-Han; You, Sheng-Chi; Minhass, Wajid Hassan

    2013-01-01

    -flow based resource binding algorithm based on breadth-first search (BFS) and minimum cost maximum flow (MCMF) in architectural-level synthesis. The experimental results show that our methodology not only makes significant reduction of valve-switching activities but also diminishes the application completion......Designs of flow-based microfluidic biochips are receiving much attention recently because they replace conventional biological automation paradigm and are able to integrate different biochemical analysis functions on a chip. However, as the design complexity increases, a flow-based microfluidic...... biochip needs more chip-integrated micro-valves, i.e., the basic unit of fluid-handling functionality, to manipulate the fluid flow for biochemical applications. Moreover, frequent switching of micro-valves results in decreased reliability. To minimize the valve-switching activities, we develop a network...

  3. Analysis of loss of flow events on Brazilian multipurpose reactor by RELAP5 code

    International Nuclear Information System (INIS)

    Soares, Humberto V.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Aronne, Ivan D.; Rezende, Guilherme P.

    2011-01-01

    The Brazilian Multipurpose Reactor (BMR) is currently being projected and analyzed. It will be a 30 MW open pool multipurpose research reactor with a compact core using Materials Testing Reactor (MTR) type fuel assembly, with planar plates. BMR will be cooled by light water and moderated by beryllium and heavy water. This work presents the calculations of steady state operation of BMR using the RELAP5 model and also three transient cases of loss of flow accident (LOFA), in the primary cooling system. A LOFA may arise through failures associated with the primary cooling system pumps or through events resulting in a decrease in the primary coolant flow with the primary cooling system pumps functioning normally. The cases presented in this paper are: primary cooling system pump shaft seizure, failure of one primary cooling system pump motor and failure of both primary cooling system pump motors. In the shaft seizure case, the flow reduction is sudden, with the blocking of the flow coast down The motor failure cases, deal with the failure of one or two pump motor due to, for example, malfunction or interruption of power and differently of the shaft seizure it can be observed the flow coast down provided by the pump inertia. It is shown that after all initiating events the reactor reaches a safe new steady state keeping the integrity of the fuel elements. (author)

  4. Analysis of loss of flow events on Brazilian multipurpose reactor by RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Humberto V.; Costa, Antonella L.; Pereira, Claubia; Veloso, Maria Auxiliadora F., E-mail: antonella@nuclear.ufmg.br, E-mail: laubia@nuclear.ufmg.br, E-mail: dora@nuclear.ufmg.br [Departamento de Engenharia Nuclear, Universidade Federal de Minas Gerais, UFMG, Belo Horizonte, MG (Brazil); Instituto Nacional de Ciencias e Tecnologia de Reatores Nucleares Inovadores, CNPq (Brazil); Aronne, Ivan D.; Rezende, Guilherme P., E-mail: aroneid@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte (Brazil).

    2011-07-01

    The Brazilian Multipurpose Reactor (BMR) is currently being projected and analyzed. It will be a 30 MW open pool multipurpose research reactor with a compact core using Materials Testing Reactor (MTR) type fuel assembly, with planar plates. BMR will be cooled by light water and moderated by beryllium and heavy water. This work presents the calculations of steady state operation of BMR using the RELAP5 model and also three transient cases of loss of flow accident (LOFA), in the primary cooling system. A LOFA may arise through failures associated with the primary cooling system pumps or through events resulting in a decrease in the primary coolant flow with the primary cooling system pumps functioning normally. The cases presented in this paper are: primary cooling system pump shaft seizure, failure of one primary cooling system pump motor and failure of both primary cooling system pump motors. In the shaft seizure case, the flow reduction is sudden, with the blocking of the flow coast down The motor failure cases, deal with the failure of one or two pump motor due to, for example, malfunction or interruption of power and differently of the shaft seizure it can be observed the flow coast down provided by the pump inertia. It is shown that after all initiating events the reactor reaches a safe new steady state keeping the integrity of the fuel elements. (author)

  5. Microgravity Multi-Phase Flow Experiment for Suborbital Testing (MFEST)

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary objective is to conduct a pathfinder, suborbital flight experiment for two-phase fluid flow and separator operations.The primary purpose of this test...

  6. Cooperative observations of air showers in Tasmania looking for anisotropies in 1013 - 1014 eV primaries (COALA project)

    International Nuclear Information System (INIS)

    Fenton, A.G.; Fenton, K.B.; Humble, J.E.

    1981-01-01

    Observations of cosmic ray air showers (median primary energy: 5.10 13 eV) in Tasmania have been planned to start during 1981. The observations will be carried out through collaboration of the Hobart and Nagoya groups, in order to catch cosmic ray flows in a somewhat stereoscopic manner with simultaneous observations in the northern hemisphere (Mt. Norikura). The air shower array consists of 18 unit trays of 4 m 2 proportional counters deployed over an area of 20 m x 160 m. The shower frequency in a fundamental coincidence mode is expected to be about 16,000 events per hour

  7. Modelling information flow along the human connectome using maximum flow.

    Science.gov (United States)

    Lyoo, Youngwook; Kim, Jieun E; Yoon, Sujung

    2018-01-01

    The human connectome is a complex network that transmits information between interlinked brain regions. Using graph theory, previously well-known network measures of integration between brain regions have been constructed under the key assumption that information flows strictly along the shortest paths possible between two nodes. However, it is now apparent that information does flow through non-shortest paths in many real-world networks such as cellular networks, social networks, and the internet. In the current hypothesis, we present a novel framework using the maximum flow to quantify information flow along all possible paths within the brain, so as to implement an analogy to network traffic. We hypothesize that the connection strengths of brain networks represent a limit on the amount of information that can flow through the connections per unit of time. This allows us to compute the maximum amount of information flow between two brain regions along all possible paths. Using this novel framework of maximum flow, previous network topological measures are expanded to account for information flow through non-shortest paths. The most important advantage of the current approach using maximum flow is that it can integrate the weighted connectivity data in a way that better reflects the real information flow of the brain network. The current framework and its concept regarding maximum flow provides insight on how network structure shapes information flow in contrast to graph theory, and suggests future applications such as investigating structural and functional connectomes at a neuronal level. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. The effect of retarding torque during a flow transient for Tehran Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Farhadi, Kazem, E-mail: kfarhadi@aeoi.org.ir [Engineering Science Research Group, Nuclear Science Research School, Nuclear Science and Technology Research Institute, AEOI, P.O. Box 11365-3486, Tehran (Iran, Islamic Republic of)

    2011-02-15

    The primary cooling system of the Tehran Research Reactor (TRR) has been analysed for a possible flow transient phenomenon caused by power cut-off. All the components of the TRR primary cooling loop that offer resistance to the coolant flow are physically modelled. Differential equations of motion for the coolant in the primary piping of the TRR and for the rotating parts of the centrifugal pump are then derived. The equation of flow motion is solved simultaneously with momentum conservation equation of the rotating parts of the pump which predicts the TRR pump speed during the flow transient. Electrical and mechanical losses are measured for the TRR three-phase induction motor in order to calculate the motor retarding torque during the event. The results of the present study are compared with the other similar primary loop results. The present model shows good agreement with the existing experimental and theoretical studies.

  9. Angra 2 small break LOCA flow regime identification through RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Marcelo da Silva; Sabundjian, Gaiane; Belchior Junior, Antonio; Andrade, Delvonei Alves de; Torres, Walmir Maximo; Conti, Thadeu das Neves; Macedo, Luiz Alberto; Umbehaun, Pedro Ernesto; Mesquita, Roberto Navarro de; Masotti, Paulo Henrique Ferraz, E-mail: msrocha@ipen.br, E-mail: gdjian@ipen.br, E-mail: abelchior@ipen.br, E-mail: delvonei@ipen.br, E-mail: wmtorres@ipen.br, E-mail: tnconti@ipen.br, E-mail: lamacedo@ipen.br, E-mail: umbehaun@ipen.br, E-mail: s, E-mail: rnavarro@ipen.br, E-mail: pmasotti@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2012-07-01

    The purpose of this paper is to identify the flow regimes in the core of Angra 2 nuclear reactor with RELAP5/MOD3.2.gamma code (RELAP5, 2001). The postulated accident is the loss of coolant through a small break in the primary circuit (SBLOCA), which is described in Chapter 15 of the Final Safety Analysis Report of Angra 2 - FSAR (ETN, 2006). As the primary circuit pressure decreases due to the loss of coolant, several alternating two phase flow regimes are established in the primary circuit. This paper analyses the coolant two-phase flow behavior in the nuclear reactor core during the postulated accident. (author)

  10. Combining Stocks and Flows of Knowledge

    DEFF Research Database (Denmark)

    Ambos, Tina C.; Nell, Phillip Christopher; Pedersen, Torben

    2013-01-01

    While previous research has mostly focused on either knowledge stocks or knowledge flows, our study is among the first to integrate these perspectives in order to shed light on the complementarity effects of different types of knowledge stocks and flows in the multinational corporation (MNC...... of complementarity create benefits for these units, but that the effects from intra-functional combinations of knowledge stocks and flows are significantly stronger than from cross-functional combinations....

  11. Border information flow architecture

    Science.gov (United States)

    2006-04-01

    This brochure describes the Border Information Flow Architecture (BIFA). The Transportation Border Working Group, a bi-national group that works to enhance coordination and planning between the United States and Canada, identified collaboration on th...

  12. VVER operational experience - effect of preconditioning and primary water chemistry on radioactivity build-up

    International Nuclear Information System (INIS)

    Zmitko, M.; Kysela, J.; Dudjakova, K.; Martykan, M.; Janesik, J.; Hanus, V.; Marcinsky, P.

    2004-01-01

    The primary coolant technology approaches currently used in VVER units are reviewed and compared with those used in PWR units. Standard and modified water chemistries differing in boron-potassium control are discussed. Preparation of the VVER Primary Water Chemistry Guidelines in the Czech Republic is noted. Operational experience of some VVER units, operated in the Czech Republic and Slovakia, in the field of the primary water chemistry, and radioactivity transport and build-up are presented. In Mochovce and Temelin units, a surface preconditioning (passivation) procedure has been applied during hot functional tests. The main principles of the controlled primary water chemistry applied during the hot functional tests are reviewed and importance of the water chemistry, technological and other relevant parameters is stressed regarding to the quality of the passive layer formed on the primary system surfaces. The first operational experience obtained in the course of beginning of these units operation is presented mainly with respect to the corrosion products coolant and surface activities. Effect of the initial passivation performed during hot functional tests and the primary water chemistry on corrosion products radioactivity level and radiation situation is discussed. (author)

  13. Continuous analysis of radioiodine isotopes in the primary coolant of NPP Paks, Hungary

    International Nuclear Information System (INIS)

    Erdoes, E.; Soos, J.; Vincze, A.; Zsille, O.; Gujgiczer, A.; Solymosi, J.; Pinter, T.

    1998-01-01

    The radioiodine analyser has been installed at the Paks-3 reactor unit. The analyser is based on an efficient and simple method of radioiodine separation: the iodine compound is converted to elementary iodine quantitatively by oxidation with potassium iodate in acid medium. Owing to its volatility, iodine is evaporated quantitatively from the primary coolant (desorption) using air flow. The air is bubbled through a solution of a reducer, and iodine is absorbed in a form which is ready for measurement. A simple NaI(Tl) detector is used for the measurement of gamma spectra. The system is controlled and data are processed by a computer. The analyser displays activity concentration data of the five iodine isotopes periodically every 15 minutes. (M.D.)

  14. 2007 Estimated International Energy Flows

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C A; Belles, R D; Simon, A J

    2011-03-10

    An energy flow chart or 'atlas' for 136 countries has been constructed from data maintained by the International Energy Agency (IEA) and estimates of energy use patterns for the year 2007. Approximately 490 exajoules (460 quadrillion BTU) of primary energy are used in aggregate by these countries each year. While the basic structure of the energy system is consistent from country to country, patterns of resource use and consumption vary. Energy can be visualized as it flows from resources (i.e. coal, petroleum, natural gas) through transformations such as electricity generation to end uses (i.e. residential, commercial, industrial, transportation). These flow patterns are visualized in this atlas of 136 country-level energy flow charts.

  15. Trophic transfer potential of aluminium oxide nanoparticles using representative primary producer (Chlorella ellipsoides) and a primary consumer (Ceriodaphnia dubia)

    International Nuclear Information System (INIS)

    Pakrashi, Sunandan; Dalai, Swayamprava; Chandrasekaran, Natarajan; Mukherjee, Amitava

    2014-01-01

    Highlights: • Trophic transfer of alumina nanoparticles using Chlorella ellipsoides and Ceriodaphnia dubia. • Subtle alterations in the feeding behaviour of the daphnids. • Disruption the energy flow through the food chain. • Transmission electron microscopy validated the disrupted feeding behaviour. - Abstract: The transfer of nanoparticles through the food chain can lead to bioaccumulation and biomagnification resulting in a long term negative impact on the ecosystem functions. The primary objective of this study was evaluation of aluminium oxide nanoparticles transfer from primary producers to primary consumers. A simple set up consisting of a primary producer (Chlorella ellipsoides) and a primary consumer (Ceriodaphnia dubia) was used. Here, C. ellipsoides were exposed to the varying concentrations of the nanoparticles ranging from 20 to 120 μg/mL (196 to 1176 μM) for 48 h and the infested algal cells were used as the feed to C. dubia. The bioaccumulation of the nanoparticles into the daphnids was noted and the biomagnification factors were computed. The exposure was noted to cause subtle alterations in the feeding behaviour of the daphnids. This might have long term consequences in the energy flow through the food chain. The reproductive behaviour of the daphnids remained unaffected upon exposure to nanoparticle infested algal feed. Distinct observations at ultra-structural scale using transmission electron microscopy provided visual evidences for the disrupted feeding behaviour upon exposure to nanoparticle treated algae. Internalization of nanoparticle like inclusion bodies in the intracellular space of algae was also detected. The findings were further substantiated by a detailed analysis of hydrodynamic stability, bioavailability and dissolution of ions from the nanoparticles over the exposure period. Altogether, the study brings out the first of its kind of observation of trophic transfer potential/behaviour of aluminium oxide nanoparticles and

  16. Trophic transfer potential of aluminium oxide nanoparticles using representative primary producer (Chlorella ellipsoides) and a primary consumer (Ceriodaphnia dubia)

    Energy Technology Data Exchange (ETDEWEB)

    Pakrashi, Sunandan; Dalai, Swayamprava; Chandrasekaran, Natarajan; Mukherjee, Amitava, E-mail: amit.mookerjea@gmail.com

    2014-07-01

    Highlights: • Trophic transfer of alumina nanoparticles using Chlorella ellipsoides and Ceriodaphnia dubia. • Subtle alterations in the feeding behaviour of the daphnids. • Disruption the energy flow through the food chain. • Transmission electron microscopy validated the disrupted feeding behaviour. - Abstract: The transfer of nanoparticles through the food chain can lead to bioaccumulation and biomagnification resulting in a long term negative impact on the ecosystem functions. The primary objective of this study was evaluation of aluminium oxide nanoparticles transfer from primary producers to primary consumers. A simple set up consisting of a primary producer (Chlorella ellipsoides) and a primary consumer (Ceriodaphnia dubia) was used. Here, C. ellipsoides were exposed to the varying concentrations of the nanoparticles ranging from 20 to 120 μg/mL (196 to 1176 μM) for 48 h and the infested algal cells were used as the feed to C. dubia. The bioaccumulation of the nanoparticles into the daphnids was noted and the biomagnification factors were computed. The exposure was noted to cause subtle alterations in the feeding behaviour of the daphnids. This might have long term consequences in the energy flow through the food chain. The reproductive behaviour of the daphnids remained unaffected upon exposure to nanoparticle infested algal feed. Distinct observations at ultra-structural scale using transmission electron microscopy provided visual evidences for the disrupted feeding behaviour upon exposure to nanoparticle treated algae. Internalization of nanoparticle like inclusion bodies in the intracellular space of algae was also detected. The findings were further substantiated by a detailed analysis of hydrodynamic stability, bioavailability and dissolution of ions from the nanoparticles over the exposure period. Altogether, the study brings out the first of its kind of observation of trophic transfer potential/behaviour of aluminium oxide nanoparticles and

  17. Effects of Faulted Stratigraphy on Saturated Zone Flow Beneath Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Cohen, Andrew J.B.; Oldenburg, Curtis M.

    1999-01-01

    The S 4 Z Model (''sub-site-scale saturated zone'') is a 3-D TOUGH2 model that was developed to study the saturated zone (SZ) at Yucca Mountain, Nevada, and to aid in the design and analysis of hydrologic tests. Yucca Mountain is the proposed site for a nuclear waste repository for the United States. The model covers an area of approximately 100 km 2 around Yucca Mountain, as shown in Figure 1. The proposed repository is located in the unsaturated zone, immediately above the area of equidimensional gridblocks east of Solitario Canyon fault, which defines the crest of Yucca Mountain. The finely discretized region near the center of the domain corresponds to the area near a cluster of boreholes used for hydraulic and tracer testing. This discretization facilitates simulation of tests conducted there. The hydrogeologic structure beneath the mountain is comprised of dipping geologic units of variable thickness which are offset by faults. One of the primary objectives of the S 4 Z modeling effort is to study the potential effects of the faulted structure on flow. Therefore, replication of the geologic structure in the model mesh is necessary. This paper summarizes (1) the mesh discretization used to capture the faulted geologic structure, and (2) a model simulation that illustrates the significance of the geologic structure on SZ flow and the resulting macrodispersion

  18. Sensory stimulation for lowering intraocular pressure, improving blood flow to the optic nerve and neuroprotection in primary open-angle glaucoma.

    Science.gov (United States)

    Rom, Edith

    2013-12-01

    Primary open-angle glaucoma is a group of optic neuropathies that can lead to irreversible blindness. Sensory stimulation in the form of acupuncture or ear acupressure may contribute to protecting patients from blindness when used as a complementary method to orthodox treatment in the form of drops, laser or surgery. The objective of this article is to provide a narrative overview of the available literature up to July 2012. It summarises reported evidence on the potential beneficial effects of sensory stimulation for glaucoma. Sensory stimulation appears to significantly enhance the pressure-lowering effect of orthodox treatments. Studies suggest that it may also improve blood flow to the eye and optic nerve head. Furthermore, it may play a role in neuroprotection through regulating nerve growth factor and brain-derived neurotrophic factor and their receptors, thereby encouraging the survival pathway in contrast to the pathway to apoptosis. Blood flow and neuroprotection are areas that are not directly influenced by orthodox treatment modalities. Numerous different treatment protocols were used to investigate the effect of sensory stimulation on intraocular pressure, blood flow or neuroprotection of the retina and optic nerve in the animal model and human pilot studies. Objective outcomes were reported to have been evaluated with Goldmann tonometry, Doppler ultrasound techniques and electrophysiology (pattern electroretinography, visually evoked potentials), and supported with histological studies in the animal model. Taken together, reported evidence from these studies strongly suggests that sensory stimulation is worthy of further research.

  19. Children's health care assistance according to their families: a comparison between models of Primary Care

    Directory of Open Access Journals (Sweden)

    Vanessa Bertoglio Comassetto Antunes de Oliveira

    2015-02-01

    Full Text Available OBJECTIVE To compare the health assistance models of Basic Traditional Units (UBS with the Family Health Strategy (ESF units for presence and extent of attributes of Primary Health Care (APS, specifically in the care of children. METHOD A cross-sectional study of a quantitative approach with families of children attended by the Public Health Service of Colombo, Paraná. The Primary Care Assessment Tool (PCA-Tool was applied to parents of 482 children, 235 ESF units and 247 UBS units covering all primary care units of the municipality, between June and July 2012. The results were analyzed according to the PCA-Tool manual. RESULTS ESF units reached a borderline overall score for primary health care standards. However, they fared better in their attributes of Affiliation, Integration of care coordination, Comprehensiveness, Family Centeredness and Accessibility of use, while the attributes of Community Guidance/Orientation, Coordination of Information Systems, Longitudinality and Access attributes were rated as insufficient for APS. UBS units had low scores on all attributes. CONCLUSION The ESF units are closer to the principles of APS (Primary Health Care, but there is need to review actions of child care aimed at the attributes of APS in both care models, corroborating similar studies from other regions of Brazil.

  20. Long-term consequences of non-intentional flows of substances: Modelling non-intentional flows of lead in the Dutch economic system and evaluating their environmental consequences

    International Nuclear Information System (INIS)

    Elshkaki, Ayman; Voet, Ester van der; Holderbeke, Mirja van; Timmermans, Veerle

    2009-01-01

    Substances may enter the economy and the environment through both intentional and non-intentional flows. These non-intentional flows, including the occurrence of substances as pollutants in mixed primary resources (metal ores, phosphate ores and fossil fuels) and their presence in re-used waste streams from intentional use may have environmental and economic consequences in terms of pollution and resource availability. On the one hand, these non-intentional flows may cause pollution problems. On the other hand, these flows have the potential to be a secondary source of substances. This article aims to quantify and model the non-intentional flows of lead, to evaluate their long-term environmental consequences, and compare these consequences to those of the intentional flows of lead. To meet this goal, the model combines all the sources of non-intentional flows of lead within one model, which also includes the intentional flows. Application of the model shows that the non-intentional flows of lead related to waste streams associated with intentional use are decreasing over time, due to the increased attention given to waste management. However, as contaminants in mixed primary resources application, lead flows are increasing as demand for these applications is increasing.

  1. Impact of enhanced flow on the flow system and wastewater ...

    African Journals Online (AJOL)

    user

    was used to estimate the impact of the excess flow on sewage-fed wetlands. Two neural network ... 33-2414-6979. The United Nations Economic and Social Development ...... developed so as to restrict the relevant parameters of the wastewater below ... is a highly efficient, low cost, low carbon emission footprint system for.

  2. Subcubic Control Flow Analysis Algorithms

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Van Horn, David

    We give the first direct subcubic algorithm for performing control flow analysis of higher-order functional programs. Despite the long held belief that inclusion-based flow analysis could not surpass the ``cubic bottleneck, '' we apply known set compression techniques to obtain an algorithm...... that runs in time O(n^3/log n) on a unit cost random-access memory model machine. Moreover, we refine the initial flow analysis into two more precise analyses incorporating notions of reachability. We give subcubic algorithms for these more precise analyses and relate them to an existing analysis from...

  3. CASH FLOW-FINANCIAL PLANNING TOOL IN THE TOURISM UNITS

    Directory of Open Access Journals (Sweden)

    Boby COSTI

    2017-05-01

    Full Text Available This paper addresses the issue of cash-flow tool for financial planning, cash flow calculation by applying the indirect method within a company in the field of tourism. Thus, it tackled issues concerning the organization of accounting of treasury which made a presentation of the subject reflected in treasury accounting record of the existence and movement of securities placement, availability of the accounts at banks, short term bank loans and other cash values. The importance of access to information as well as more detailed and clearer leads to an upward trend of the tourism society. Standardization of definitions helps to ensure that all parties are talking of the same terms or concepts with lower or no variables. This is essential for developers and contractors in different geographical regions of the world and different countries when they discuss issues of tourism and travel.

  4. Refrigeration generation using expander-generator units

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.

    2016-05-01

    The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.

  5. Atomizing industrial gas-liquid flows – Development of an efficient hybrid VOF-LPT numerical framework

    International Nuclear Information System (INIS)

    Ström, Henrik; Sasic, Srdjan; Holm-Christensen, Olav; Shah, Louise Jivan

    2016-01-01

    Highlights: • Modelling of turbulent atomizing gas-liquid flows in real industrial devices. • A combined VOF-LPT framework with statistical coupling. • Regions of separated and dispersed multiphase flow treated simultaneously. • Statistical model based on a limited amount of highly resolved VOF data. - Abstract: Atomizing gas-liquid flows are used in industrial applications where high interphase heat and mass transfer rates and good mixing are of primary importance. Today, there is no single mathematical framework available to predict the entire liquid breakup process at an acceptable computational cost for a typical problem of industrial size. In this work, we develop a volume-of-fluid (VOF) framework that is combined with Lagrangian particle tracking (LPT) to take advantage of the respective strengths of these two approaches. The two frameworks are coupled via a statistical model that enables a transition from the VOF to the LPT formulation using input data about the primary breakup process obtained from detailed VOF simulations in dedicated switching zones. LPT-to-VOF transitions are handled directly by analyzing the proximity of LPT parcels to larger VOF structures. The combined framework is specifically designed to accommodate situations where atomization occurs in several locations simultaneously and when separated and dispersed turbulent gas-liquid flows co-exist in the same industrial unit. The procedure in which the statistical model is derived is presented and discussed, its performance is verified and the computational efficiency of the combined VOF-LPT model is assessed. Finally, the application of the coupled framework to the simulation of an industrial gas-liquid mixer with four separate atomization regions is presented.

  6. The influence of core bypass flow during SBLOCA

    International Nuclear Information System (INIS)

    Maselj, A.; Jurkovic, M.

    1996-01-01

    Many parameters affect the behaviour of a NPP during a Small Break Loss of Coolant Accident (SBLOCA). The bypass flow between the core side and the downcomer is one of them. Different PWRs have different values of core bypass flow. In spite of the complexity of the real situation in the primary system during SBLOCA, some fundamental details of the phenomena can be explained with simplified mathematical models, which relate on basic parameters of the primary coolant. These models define the conditions for loop seal clearance and final results are confirmed with measured values. The analysis presented in the paper refers to Bethsy Test 9.1.b SB LOCA scenario, with variation of core bypass flow. Basic RELAP5 input model calculation results show very good agreement with the experimental data. The core liquid level depression before loop seal clearance is lower in case of smaller core bypass flow. This affects the fuel clad temperature because of different heat transfer mechanisms. Time of loop seal clearance is delayed with larger core bypass flow and consequently lower differential pressure between downcomer and core. (author)

  7. Counter rotating type hydroelectric unit suitable for tidal power station

    International Nuclear Information System (INIS)

    Kanemoto, T; Suzuki, T

    2010-01-01

    The counter rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures,was proposed to utilize effectively the tidal power. In the unit, the front and the rear runners counter drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the flow direction at the front runner inlet, because the angular momentum through the rear runner must coincides with that through the front runner. That is, the flow runs in the axial direction at the rear runner outlet while the axial inflow at the front runner inlet. Such operations are suitable for working at the seashore with rising and falling tidal flows, and the unit may be able to take place of the traditional bulb type turbines. The tandem runners were operated at the on-cam conditions, in keeping the induced frequency constant. The output and the hydraulic efficiency are affected by the adjustment of the front and the blade setting angles. The both optimum angles giving the maximum output and/or efficiency were presented at the various discharges/heads. To promote more the tidal power generation by this type unit, the runners were also modified so as to be suitable for both rising and falling flows. The hydraulic performances are acceptable while the output is determined mainly by the trailing edge profiles of the runner blades.

  8. Effect of Cooling Units on the Performance of an Automotive Exhaust-Based Thermoelectric Generator

    Science.gov (United States)

    Su, C. Q.; Zhu, D. C.; Deng, Y. D.; Wang, Y. P.; Liu, X.

    2017-05-01

    Currently, automotive exhaust-based thermoelectric generators (AETEGs) are a hot topic in energy recovery. In order to investigate the influence of coolant flow rate, coolant flow direction and cooling unit arrangement in the AETEG, a thermoelectric generator (TEG) model and a related test bench are constructed. Water cooling is adopted in this study. Due to the non-uniformity of the surface temperature of the heat source, the coolant flow direction would affect the output performance of the TEG. Changing the volumetric flow rate of coolant can increase the output power of multi-modules connected in series or/and parallel as it can improve the temperature uniformity of the cooling unit. Since the temperature uniformity of the cooling unit has a strong influence on the output power, two cooling units are connected in series or parallel to research the effect of cooling unit arrangements on the maximum output power of the TEG. Experimental and theoretical analyses reveal that the net output power is generally higher with cooling units connected in parallel than cooling units connected in series in the cooling system with two cooling units.

  9. [Community vegetable gardens as a health promotion activity: an experience in Primary Healthcare Units].

    Science.gov (United States)

    Costa, Christiane Gasparini Araújo; Garcia, Mariana Tarricone; Ribeiro, Silvana Maria; Salandini, Marcia Fernanda de Sousa; Bógus, Cláudia Maria

    2015-10-01

    Urban and peri-urban agriculture (UPA) is being practiced in different settings, contributing to the improvement of health in communities and healthier environments. In order to identify the meanings and implications of the practice of UPA in Primary Healthcare Units (PHU) as an activity of health promotion (HP), and to what extent its therapeutic dimension characterizes it as an activity aligned with complementary and integrative practices (CIP), a qualitative cross-sectional study was performed in Embu das Artes, State of São Paulo. From the analysis, the following main themes arose: health concept, health outcomes, the return to traditional practices and habits and the reorientation of health services. It was possible to identify the close link between the cultivation of vegetable gardens and HP guidelines and fields of action, such as creating healthier environments, boosting community actions, developing personal skills, stimulating autonomy and empowerment and demands for the reorientation of services. The garden activities, set up in PHU areas, proved to be an implementation strategy of CIP. The conclusion reached is that vegetable gardening activities in community gardens are seen to be health promotion practices that integrate key elements of CIP.

  10. Mathematical modeling of a zinc/bromine flow cell and a lithium/thionyl chloride primary cell

    Energy Technology Data Exchange (ETDEWEB)

    Evans, T.I.

    1988-01-01

    Three mathematical models are presented, one for the secondary zinc/bromine flow cell and two for the lithium/thionyl chloride primary cell. The objectives in this modeling work are to aid in understanding the physical phenomena affecting cell performance, determine methods of improving cell performance and safety, and reduce the experimental efforts needed to develop these electrochemical systems. The zinc/bromine cell model is the first such model to include a porous layer on the bromine electrode and to predict discharge behavior. The model is used to solve simultaneously the component material balances and the electroneutrality condition for the unknowns, species concentrations and the solution potential. Two models are presented for the lithium/thionyl chloride cell. The first model is a detailed one-dimensional model which is used to solve simultaneously the component material balances, Ohm's law relations, and current balance. The independent design criteria are identified from the model development. The second model presented here is a two-dimensional thermal model for the spirally would configuration of the lithium/thionyl chloride cell. This is the first model to address the effects of the spiral geometry on heat transfer in the cell.

  11. Noninvasive measurement of cerebrospinal fluid flow using an ultrasonic transit time flow sensor: a preliminary study.

    Science.gov (United States)

    Pennell, Thomas; Yi, Juneyoung L; Kaufman, Bruce A; Krishnamurthy, Satish

    2016-03-01

    OBJECT Mechanical failure-which is the primary cause of CSF shunt malfunction-is not readily diagnosed, and the specific reasons for mechanical failure are not easily discerned. Prior attempts to measure CSF flow noninvasively have lacked the ability to either quantitatively or qualitatively obtain data. To address these needs, this preliminary study evaluates an ultrasonic transit time flow sensor in pediatric and adult patients with external ventricular drains (EVDs). One goal was to confirm the stated accuracy of the sensor in a clinical setting. A second goal was to observe the sensor's capability to record real-time continuous CSF flow. The final goal was to observe recordings during instances of flow blockage or lack of flow in order to determine the sensor's ability to identify these changes. METHODS A total of 5 pediatric and 11 adult patients who had received EVDs for the treatment of hydrocephalus were studied in a hospital setting. The primary EVD was connected to a secondary study EVD that contained a fluid-filled pressure transducer and an in-line transit time flow sensor. Comparisons were made between the weight of the drainage bag and the flow measured via the sensor in order to confirm its accuracy. Data from the pressure transducer and the flow sensor were recorded continuously at 100 Hz for a period of 24 hours by a data acquisition system, while the hourly CSF flow into the drip chamber was recorded manually. Changes in the patient's neurological status and their time points were noted. RESULTS The flow sensor demonstrated a proven accuracy of ± 15% or ± 2 ml/hr. The flow sensor allowed real-time continuous flow waveform data recordings. Dynamic analysis of CSF flow waveforms allowed the calculation of the pressure-volume index. Lastly, the sensor was able to diagnose a blocked catheter and distinguish between the blockage and lack of flow. CONCLUSIONS The Transonic flow sensor accurately measures CSF output within ± 15% or ± 2 ml

  12. Arsenic in Ground Water of the United States

    Science.gov (United States)

    ... Team More Information Arsenic in groundwater of the United States Arsenic in groundwater is largely the result of ... Gronberg (2011) for updated arsenic map. Featured publications United States Effects of human-induced alteration of groundwater flow ...

  13. A mechanistic model for predicting flow-assisted and general corrosion of carbon steel in reactor primary coolants

    Energy Technology Data Exchange (ETDEWEB)

    Lister, D. [University of New Brunswick, Fredericton, NB (Canada). Dept. of Chemical Engineering; Lang, L.C. [Atomic Energy of Canada Ltd., Chalk River Lab., ON (Canada)

    2002-07-01

    Flow-assisted corrosion (FAC) of carbon steel in high-temperature lithiated water can be described with a model that invokes dissolution of the protective oxide film and erosion of oxide particles that are loosened as a result. General corrosion under coolant conditions where oxide is not dissolved is described as well. In the model, the electrochemistry of magnetite dissolution and precipitation and the effect of particle size on solubility move the dependence on film thickness of the diffusion processes (and therefore the corrosion rate) away from reciprocal. Particle erosion under dissolving conditions is treated stochastically and depends upon the fluid shear stress at the surface. The corrosion rate dependence on coolant flow under FAC conditions then becomes somewhat less than that arising purely from fluid shear (proportional to the velocity squared). Under non-dissolving conditions, particle erosion occurs infrequently and general corrosion is almost unaffected by flow For application to a CANDU primary circuit and its feeders, the model was bench-marked against the outlet feeder S08 removed from the Point Lepreau reactor, which furnished one value of film thickness and one of corrosion rate for a computed average coolant velocity. Several constants and parameters in the model had to be assumed or were optimised, since values for them were not available. These uncertainties are no doubt responsible for the rather high values of potential that evolved as steps in the computation. The model predicts film thickness development and corrosion rate for the whole range of coolant velocities in outlet feeders very well. In particular, the detailed modelling of FAC in the complex geometry of one outlet feeder (F11) is in good agreement with measurements. When the particle erosion computations are inserted in the balance equations for the circuit, realistic values of crud level are obtained. The model also predicts low corrosion rates and thick oxide films for inlet

  14. A mechanistic model for predicting flow-assisted and general corrosion of carbon steel in reactor primary coolants

    International Nuclear Information System (INIS)

    Lister, D.

    2002-01-01

    Flow-assisted corrosion (FAC) of carbon steel in high-temperature lithiated water can be described with a model that invokes dissolution of the protective oxide film and erosion of oxide particles that are loosened as a result. General corrosion under coolant conditions where oxide is not dissolved is described as well. In the model, the electrochemistry of magnetite dissolution and precipitation and the effect of particle size on solubility move the dependence on film thickness of the diffusion processes (and therefore the corrosion rate) away from reciprocal. Particle erosion under dissolving conditions is treated stochastically and depends upon the fluid shear stress at the surface. The corrosion rate dependence on coolant flow under FAC conditions then becomes somewhat less than that arising purely from fluid shear (proportional to the velocity squared). Under non-dissolving conditions, particle erosion occurs infrequently and general corrosion is almost unaffected by flow For application to a CANDU primary circuit and its feeders, the model was bench-marked against the outlet feeder S08 removed from the Point Lepreau reactor, which furnished one value of film thickness and one of corrosion rate for a computed average coolant velocity. Several constants and parameters in the model had to be assumed or were optimised, since values for them were not available. These uncertainties are no doubt responsible for the rather high values of potential that evolved as steps in the computation. The model predicts film thickness development and corrosion rate for the whole range of coolant velocities in outlet feeders very well. In particular, the detailed modelling of FAC in the complex geometry of one outlet feeder (F11) is in good agreement with measurements. When the particle erosion computations are inserted in the balance equations for the circuit, realistic values of crud level are obtained. The model also predicts low corrosion rates and thick oxide films for inlet

  15. Titanium recycling in the United States in 2004, chap. Y of Sibley, S.F., ed., Flow studies for recycling metal commodities in the United States

    Science.gov (United States)

    Goonan, Thomas G.

    2010-01-01

    As one of a series of reports that describe the recycling of metal commodities in the United States, this report discusses the titanium metal fraction of the titanium economy, which generates and uses titanium metal scrap in its operations. Data for 2004 were selected to demonstrate the titanium flows associated with these operations. This report includes a description of titanium metal supply and demand in the United States to illustrate the extent of titanium recycling and to identify recycling trends. In 2004, U.S. apparent consumption of titanium metal (contained in various titanium-bearing products) was 45,000 metric tons (t) of titanium, which was distributed as follows: 25,000 t of titanium recovered as new scrap, 9,000 t of titanium as titanium metal and titanium alloy products delivered to the U.S. titanium products reservoir, 7,000 t of titanium consumed by steelmaking and other industries, and 4,000 t of titanium contained in unwrought and wrought products exported. Titanium recycling is concentrated within the titanium metals sector of the total titanium market. The titanium market is otherwise dominated by pigment (titanium oxide) products, which generate dissipative losses instead of recyclable scrap. In 2004, scrap (predominantly new scrap) was the source of roughly 54 percent of the titanium metal content of U.S.-produced titanium metal products.

  16. Topology optimization of inertia driven dosing units

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe

    2017-01-01

    This paper presents a methodology for optimizing inertia driven dosing units, sometimes referred to as eductors, for use in small scale flow applications. The unit is assumed to operate at low to moderate Reynolds numbers and under steady state conditions. By applying topology optimization...

  17. Is primary care ready to take on Attention Deficit Hyperactivity Disorder?

    Directory of Open Access Journals (Sweden)

    Thapar Anita

    2002-04-01

    Full Text Available Abstract Background Attention Deficit Hyperactivity Disorder (ADHD is a common childhood psychiatric disorder. The management of ADHD has recently been highlighted. The National Institute of Clinical Excellence (NICE and Scottish Intercollegiate Guidelines network (SIGN have both produced management guidelines. Doctors working within Primary Care in countries such as the United States play an important role in the management of ADHD. In the United Kingdom however the role of doctors in primary care in the management of ADHD, both individually and within shared care protocols, is only now being identified and defined. Is this role for Primary Care likely to be acceptable and effective? Discussion There is some evidence that doctors working within Primary Care in the United Kingdom are willing to follow up children on medication for ADHD and carry out monitoring of physical status. However many feel unconfident in the management of ADHD and most have received little or no training in child psychiatry. There are also concerns that adverse media reports will have an undue influence on the attitudes of doctors within primary care to families with children suffering from ADHD. Summary There are important barriers to be tackled before shared care protocols for ADHD can be successfully implemented in the United Kingdom. Tailored information about ADHD needs to be provided to doctors in primary care. Clear dialogue between planners and healthcare professionals from both primary and secondary care is essential to ensure that service delivery is acceptable to healthcare providers, tailored to their skills and is adequately resourced.

  18. Prognostic Value of Transthoracic Doppler Echocardiography Coronary Flow Velocity Reserve in Patients with Nonculprit Stenosis of Intermediate Severity Early after Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Tesic, Milorad; Djordjevic-Dikic, Ana; Giga, Vojislav; Stepanovic, Jelena; Dobric, Milan; Jovanovic, Ivana; Petrovic, Marija; Mehmedbegovic, Zlatko; Milasinovic, Dejan; Dedovic, Vladimir; Zivkovic, Milorad; Juricic, Stefan; Orlic, Dejan; Stojkovic, Sinisa; Vukcevic, Vladan; Stankovic, Goran; Nedeljkovic, Milan; Ostojic, Miodrag; Beleslin, Branko

    2018-04-03

    Treatment of nonculprit coronary stenosis during primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction may be beneficial, but the mode and timing of the intervention are still controversial. The aim of this study was to examine the significance and prognostic value of preserved coronary flow velocity reserve (CFVR) in patients with nonculprit intermediate stenosis early after primary percutaneous coronary intervention. Two hundred thirty patients with remaining intermediate (50%-70%) stenosis of non-infarct-related arteries, in whom CFVR was performed within 7 days after primary percutaneous coronary intervention, were prospectively enrolled. Twenty patients with reduced CFVR and positive results on stress echocardiography or impaired fractional flow reserve underwent revascularization and were not included in further analysis. The final study population of 210 patients (mean age, 58 ± 10 years; 162 men) was divided into two groups on the basis of CFVR: group 1, CFVR > 2 (n = 174), and group 2, CFVR ≤ 2 (n = 36). Cardiac death, nonfatal myocardial infarction, and revascularization of the evaluated vessel were considered adverse events. Mean follow-up duration was 47 ± 16 months. Mean CFVR for the whole group was 2.36 ± 0.40. There were six adverse events (3.4%) related to the nonculprit coronary artery in group 1, including one cardiac death, one ST-segment elevation myocardial infarction, and four revascularizations. In group 2, there were 30 adverse events (83.3%, P  2 of the intermediate nonculprit coronary lesion, deferral of revascularization is safe and associated with excellent long-term clinical outcomes. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  19. PACTOLUS, Nuclear Power Plant Cost and Economics by Discounted Cash Flow Method. CLOTHO, Mass Flow Data Calculation for Program PACTOLUS

    International Nuclear Information System (INIS)

    Haffner, D.R.

    1976-01-01

    1 - Description of problem or function: PACTOLUS is a code for computing nuclear power costs using the discounted cash flow method. The cash flows are generated from input unit costs, time schedules and burnup data. CLOTHO calculates and communicates to PACTOLUS mass flow data to match a specified load factor history. 2 - Method of solution: Plant lifetime power costs are calculated using the discounted cash flow method. 3 - Restrictions on the complexity of the problem - Maxima of: 40 annual time periods into which all costs and mass flows are accumulated, 20 isotopic mass flows charged into and discharged from the reactor model

  20. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....

  1. Temperature distribution in the Temelin NPP primary circuit piping

    International Nuclear Information System (INIS)

    Blaha, V.; Maca, K.; Kodl, P.; Kroj, L.

    2004-01-01

    Temperature non-homogeneity in the VVER 1000 reactor primary piping hot legs was detected during the commissioning of Temelin units 1 and 2. A quantification of temperature differences was carried out and explanation of its causes was presented. Mathematical analysis of the effect was carried out using the PHOENICS 3.4 code, and the results were processed graphically by means of a post processor PHOTON and by means of a user program allowing statistic evaluation of temperature profiles at the core outlet and in the area of the temperature-measurement pits. The coolant temperatures in the core area increased gradually following the given radial and axial distribution of output from the inlet temperature of 288.1 degC to 315-331 degC at the core outlet. The temperature profile was balanced and in the IO piping in the area of temperature-measurement pits the difference of the maximum and minimum temperature value was approx. 1 degC according to the calculation. The temperature field shape is mainly determined by the radial distribution of the core output. The mean outlet temperature from the core weighted through mass flow is determined by the flow through the core and by the total output. The calculated temperature span at the core outlet in the range of 315 - 331 degC corresponded well with the measured values during the operation. The values were in the range of 310-333 degC, however, the in-core thermocouple inaccuracy should also be taken into consideration. On the other hand, the temperature span in the area of temperature-measurement pits was actually about 4 times higher than the calculated temperature (observed: 4 degC as against the calculated 1 degC). A good agreement was reached between the analysis results and the actual condition of the nuclear unit in the area of the core outlet. (P.A.)

  2. Lectures on mean curvature flows

    CERN Document Server

    Zhu, Xi-Ping

    2002-01-01

    "Mean curvature flow" is a term that is used to describe the evolution of a hypersurface whose normal velocity is given by the mean curvature. In the simplest case of a convex closed curve on the plane, the properties of the mean curvature flow are described by Gage-Hamilton's theorem. This theorem states that under the mean curvature flow, the curve collapses to a point, and if the flow is diluted so that the enclosed area equals \\pi, the curve tends to the unit circle. In this book, the author gives a comprehensive account of fundamental results on singularities and the asymptotic behavior of mean curvature flows in higher dimensions. Among other topics, he considers in detail Huisken's theorem (a generalization of Gage-Hamilton's theorem to higher dimension), evolution of non-convex curves and hypersurfaces, and the classification of singularities of the mean curvature flow. Because of the importance of the mean curvature flow and its numerous applications in differential geometry and partial differential ...

  3. Two-phase flow through small branches in a horizontal pipe with stratified flow

    International Nuclear Information System (INIS)

    Smoglie, C.

    1985-02-01

    In the field of reactor safety the occurrence of a small break in a horizontal primary coolant pipe is of great importance. This report presents the description and results of experiments designed to determine the mass flow rate and quality through a small break at the bottom, the top or the side of a main pipe with stratified gas-liquid flow. If the interface level is far below (above) the branch, only single-phase gas (liquid) flow enters the branch. For smaller distances the interface is locally deformed because of the pressure decrease due to the fluid acceleration near the branch inlet (Bernoulli effect) and liquid (gas) can be entrained. This report contains photographs illustrating the flow phenomena as well as a general correlation to determine the beginning of entrainment. Results are presented on the branch mass flow rate and quality as a function of a normalized distance between the interface and the branch inlet. A model was developed which enables to predict the branch quality and mass flux. Results from air-water flow through horizontal branches, were extrapolated for steam water flow at high pressure with critical branch mass flux. (orig./HS) [de

  4. Flow regimes and heat transfer modes identification in ANGRA 2 core, during small break in the primary loop with area of 100 cm2, simulated with RELAP5 code

    International Nuclear Information System (INIS)

    Borges, Eduardo M.; Sabundjian, Gaiane

    2015-01-01

    Identifying the flow regimes and the heat transfer modes is important for the analysis of accidents such as the Loss-of-Coolant Accident (LOCA). The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used in the RELAP5/MOD3.2.gama code in ANGRA 2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 100cm 2 -rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of ANGRA 2 (FSAR - A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of ANGRA 2 during the postulated accident. (author)

  5. Cardiovascular risk rate in hypertensive patients attended in primary health care units: the influence of pharmaceutical care

    Directory of Open Access Journals (Sweden)

    Paulo Yuri Milen Firmino

    2015-09-01

    Full Text Available Cardiovascular complications are relevant due to their frequency and severity on the hypertension scenario. Studies refer Pharmaceutical Care (PC as capable of decreasing cardiovascular risk rate (%CVR on hypertensive patients. This study aimed to investigate, through a randomized clinical assay, the influence of PC service on the %CVR of hypertensive patients assisted in a health primary care unit from Fortaleza-Ceará. Two study groups were formed: i. Intervention Group (IG, which received orientation about taking medicines, actions aiming to prevent/solve medicine interactions and adverse effects and non-pharmacological interventions for 9 months and, ii. Control Group (CG, which received traditional assistance of the unit and was monitored during the same period. It was observed a statistically significant reduction on %CVR (10.76 to 7.86; p=0.04 and systolic blood pressure levels (SBP (137.69 to 131.54; p<0.01 in the IG, while, in the CG, there was no significant alteration. 151 Drug Related Problem (DRP were identified and it was realized 124 pharmaceutical interventions, with 89.2% of them resulting on solution/prevention of the problem. Our findings indicated that the inclusion of the PC service in the hypertensive health assistance was more effective at the %CVR and the SBP reduction in comparison to the traditional assistance offered.

  6. Large-eddy simulation of flow over a grooved cylinder up to transcritical Reynolds numbers

    KAUST Repository

    Cheng, W.; Pullin, D. I.; Samtaney, Ravi

    2017-01-01

    for flow past a cylinder with different surface topographies is the result of a change in the global flow state generated by an interaction of primary flow separation with secondary flow recirculating motions that manifest as a mean-flow secondary bubble

  7. A Generalized Minimum Cost Flow Model for Multiple Emergency Flow Routing

    Directory of Open Access Journals (Sweden)

    Jianxun Cui

    2014-01-01

    Full Text Available During real-life disasters, that is, earthquakes, floods, terrorist attacks, and other unexpected events, emergency evacuation and rescue are two primary operations that can save the lives and property of the affected population. It is unavoidable that evacuation flow and rescue flow will conflict with each other on the same spatial road network and within the same time window. Therefore, we propose a novel generalized minimum cost flow model to optimize the distribution pattern of these two types of flow on the same network by introducing the conflict cost. The travel time on each link is assumed to be subject to a bureau of public road (BPR function rather than a fixed cost. Additionally, we integrate contraflow operations into this model to redesign the network shared by those two types of flow. A nonconvex mixed-integer nonlinear programming model with bilinear, fractional, and power components is constructed, and GAMS/BARON is used to solve this programming model. A case study is conducted in the downtown area of Harbin city in China to verify the efficiency of proposed model, and several helpful findings and managerial insights are also presented.

  8. Geomorphic change in the Limitrophe reach of the Colorado River in response to the 2014 delta pulse flow, United States and Mexico

    Science.gov (United States)

    Mueller, Erich R.; Schmidt, John C.; Topping, David; Grams, Paul E.

    2015-01-01

    A pulse of water was released from Morelos Dam into the dry streambed of the Colorado River in its former delta on March 23, 2014. Although small in relation to delta floods of a century ago, this was the first flow to reach the sea in nearly two decades. The pulse flow was significant in that it resulted from an international agreement, Minute 319, which allowed Colorado River water to be used for environmental restoration. Here we present a historical perspective of channel change and the results of geomorphic and sediment transport monitoring during the pulse flow between Yuma, Arizona and San Luis Rio Colorado, Sonora. This reach is known as the Limitrophe, because the river channel is the legal border between the United States and Mexico. Peak discharge of the pulse flow was 120 m3/s at Morelos Dam, but decreased to 71 m3/s at the southern border because of infiltration losses to the dry streambed. In contrast, flood flows in the 1980s and 1990s peaked above 600 m3/s at the southern border, and high flows above 200 m3/s were common. The sustained high flows in the 1980s caused widening and reworking of the river channel downstream through the delta. In the Limitrophe, flooding in 1993 from the Gila River basin dissected the 1980s flood surfaces, and smaller floods in the late 1990s incised the modern “active” channel within these higher surfaces. Field observations show that most geomorphic change during the pulse flow was confined to this pre-pulse, active channel. Relatively little bank erosion was evident, particularly in upstream reaches where vegetation is most dense, but new sandbars formed in areas of flow expansion. Farther downstream, localized bed scour and deposition ranged from 10s of centimeters to more than a meter, and fluvial dunes aggraded the bed in several locations. Measurable suspended-sediment transport occurred throughout the Limitrophe. Sediment concentrations peaked during the rising limb, and suspended sand concentrations suggest

  9. Termination unit

    Energy Technology Data Exchange (ETDEWEB)

    Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C.; Lindsay, David; Fisher, Paul W.; Nielsen, Carsten Thidemann

    2016-05-03

    Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

  10. Flow processes in electric discharge drivers

    Science.gov (United States)

    Baganoff, D.

    1975-01-01

    The performance of an electric discharge shock tube is discussed from the point of view that the conditions at the sonic station are the primary controlling variables (likewise in comparing designs), and that the analysis of the flow on either side of the sonic station should be done separately. The importance of considering mass-flow rate in matching a given driver design to the downstream flow required for a particular shock-wave speed is stressed. It is shown that a driver based on the principle of liquid injection (of H2) is superior to one based on the Ludwieg tube, because of the greater mass-flow rate and the absence of a massive diaphragm.

  11. Valuing ecosystem services. A shadow price for net primary production

    International Nuclear Information System (INIS)

    Richmond, Amy; Kaufmann, Robert K.; Myneni, Ranga B.

    2007-01-01

    We analyze the contribution of ecosystem services to GDP and use this contribution to calculate an empirical price for ecosystem services. Net primary production is used as a proxy for ecosystem services and, along with capital and labor, is used to estimate a Cobb Douglas production function from an international panel. A positive output elasticity for net primary production probably measures both marketed and nonmarketed contributions of ecosystems services. The production function is used to calculate the marginal product of net primary production, which is the shadow price for ecosystem services. The shadow price generally is greatest for developed nations, which have larger technical scalars and use less net primary production per unit output. The rate of technical substitution indicates that the quantity of capital needed to replace a unit of net primary production tends to increase with economic development, and this rate of replacement may ultimately constrain economic growth. (author)

  12. Design and test of ASME strainer for primary cooling system in HANARO

    International Nuclear Information System (INIS)

    Park, Yong-Chul; Ryu, Jeong-Soo

    1999-01-01

    The ASME strainers have been newly installed at the suction side of each reactor coolant pump to get rid of the foreign materials which may damage the pump impeller or interfere with the coolant path of fuel flow tube or primary plate type heat exchanger. The strainer was designed in accordance with ASME SEC. III, DIV. 1, ND and the structural integrity was verified by seismic analysis. The screen was designed in accordance with the effective void area from the result of flow analysis for T-type strainer. After installation of the strainer, it was confirmed through the field test that the flow characteristics of primary cooling system were not adversely affected. The pressure loss coefficient was calculated by Darcy equation using the pressure difference through each strainer and the flow rate measured during the strainer performance test. And these are useful data to predict flow variations by the pressure difference. (author)

  13. Two-phase flow phenomena in broken recirculation line of BWR

    International Nuclear Information System (INIS)

    Kato, Masami; Arai, Kenji; Narabayashi, Tadashi; Amano, Osamu.

    1986-01-01

    When a primary recirculation line of BWR is ruptured, a primary recirculation pump may be subjected to very high velocity two-phase flow and its speed may be accelerated by this flow. It is important for safety evaluation to estimate the pump behavior during blowdown. There are two problems involved in analyzing this behavior. One problem concerns the pump characteristics under two-phase flow. The other involves the two-phase conditions at the pump inlet. If the rupture occurs at a suction side of the pump, choking is considered to occur at a broken jet pump nozzle. Then, a void fraction becomes larger downstream from the jet pump nozzle and volumetric flow through the pump will be very high. However, there is little experimental data available on two-phase flow downstream from a choking plane. Blowdown tests were performed using a simulated broken recirculation line and measured data were analyzed by TRAC-PlA. Analytical results agreed with measured data. (author)

  14. Instrumentation for localized measurements in two-phase flow conditions

    International Nuclear Information System (INIS)

    Neff, G.G.; Averill, R.H.; Shurts, S.W.

    1979-01-01

    Three types of instrumentation that have been developed by EG and G Idaho, Inc., and its predecessor, Aerojet Nuclear company, at the Idaho National Engineering Laboratory to investigate two-phase flow phenomenon in a nuclear reactor at the Loss-of-Fluid Test (LOFT) facility are discussed: (a) a combination drag disc-turbine transducer (DTT), (b) a multibeam nuclear hardened gamma densitometer system, and (c) a conductivity sensitive liquid level transducer (LLT). The DTT obtains data on the complex problem of two-phase flow conditions in the LOFT primary coolant system during a loss-os-coolant experiment (LOCE). The discussion of the DTT describes how a turbine, measuring coolant velocity, and a drag disc, measuring coolant momentum flux, can provide valuable mass flow data. The nuclear hardened gamma densitometer is used to obtain density and flow regime information for two-phase flow in the LOFT primary coolant system during a LOCE. The LLT is used to measure water and steam conditions within the LOFT reactor core during a LOCE. The LLT design and the type of data obtained are described

  15. Simulation of groundwater flow in the glacial aquifer system of northeastern Wisconsin with variable model complexity

    Science.gov (United States)

    Juckem, Paul F.; Clark, Brian R.; Feinstein, Daniel T.

    2017-05-04

    The U.S. Geological Survey, National Water-Quality Assessment seeks to map estimated intrinsic susceptibility of the glacial aquifer system of the conterminous United States. Improved understanding of the hydrogeologic characteristics that explain spatial patterns of intrinsic susceptibility, commonly inferred from estimates of groundwater age distributions, is sought so that methods used for the estimation process are properly equipped. An important step beyond identifying relevant hydrogeologic datasets, such as glacial geology maps, is to evaluate how incorporation of these resources into process-based models using differing levels of detail could affect resulting simulations of groundwater age distributions and, thus, estimates of intrinsic susceptibility.This report describes the construction and calibration of three groundwater-flow models of northeastern Wisconsin that were developed with differing levels of complexity to provide a framework for subsequent evaluations of the effects of process-based model complexity on estimations of groundwater age distributions for withdrawal wells and streams. Preliminary assessments, which focused on the effects of model complexity on simulated water levels and base flows in the glacial aquifer system, illustrate that simulation of vertical gradients using multiple model layers improves simulated heads more in low-permeability units than in high-permeability units. Moreover, simulation of heterogeneous hydraulic conductivity fields in coarse-grained and some fine-grained glacial materials produced a larger improvement in simulated water levels in the glacial aquifer system compared with simulation of uniform hydraulic conductivity within zones. The relation between base flows and model complexity was less clear; however, the relation generally seemed to follow a similar pattern as water levels. Although increased model complexity resulted in improved calibrations, future application of the models using simulated particle

  16. Bellefonte primary containment structure

    International Nuclear Information System (INIS)

    Olyniec, J.H.

    1981-01-01

    Construction of the reactor building primary containment structure at the Bellefonte Nuclear Plant involved several specialized construction techniques. This two unit plant is one of the nine nuclear units at six different sites now under construction by the Tennessee Valley Authority (TVA). The post-Tensioned, cast-in-place interior steel lined containment structure is unique within TVA. Problems during construction were identified at weekly planning meetings, and options were discussed. Close coordination between craft supervisors and on-site engineering personnel drew together ''hands-on''experience and technical background. Details of the construction techniques, problems, and solutions are presented

  17. Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    OpenAIRE

    Hamasaki, Shin-ichi; Mukai, Ryosuke; Yano, Yoshihiro; Tsuji, Mineo

    2014-01-01

    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is...

  18. Accessibility to primary health care services in the state of Goiás

    Directory of Open Access Journals (Sweden)

    Juliana Pires Ribeiro

    2015-09-01

    Full Text Available The objective of this study was to evaluate accessibility to primary health care services in the state of Goiás. A descriptive cross-sectional study was conducted based on secondary data from the National Program to Improve Access to and Quality of Primary Health Care. The study sample was composed of health professionals from 1,216 primary health care units. Results showed that 68.5% of the health units miss a screening room, thus considerably damaging prompt decision-making by professionals. The lack of medical offices in 2% of the sites hinders the primary health care services accessibility in Goiás. As regards opening hours and work shifts, 86% of the units are open five days a week in eight-hour shifts, which does not favor accessibility for users. This study confirms the lack of accessibility to health services and the need for additional investments to strengthen primary health care.

  19. Flow regimes and heat transfer modes identification in ANGRA 2 core, during small break in the primary loop with area of 100 cm{sup 2}, simulated with RELAP5 code

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Eduardo M.; Sabundjian, Gaiane, E-mail: gdgian@ipen.br, E-mail: borges.em@hotmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Identifying the flow regimes and the heat transfer modes is important for the analysis of accidents such as the Loss-of-Coolant Accident (LOCA). The aim of this paper is to identify the flow regimes, the heat transfer modes, and the correlations used in the RELAP5/MOD3.2.gama code in ANGRA 2 during the Small-Break Loss-of-Coolant Accident (SBLOCA) with a 100cm{sup 2}-rupture area in the cold leg of primary loop. The Chapter 15 of the Final Safety Analysis Report of ANGRA 2 (FSAR - A2) reports this specific kind of accident. The results from this work demonstrated the several flow regimes and heat transfer modes that can be present in the core of ANGRA 2 during the postulated accident. (author)

  20. Phase I Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada with Errata Sheet 1, 2, 3, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Greg Ruskauff

    2009-02-01

    As prescribed in the Pahute Mesa Corrective Action Investigation Plan (CAIP) (DOE/NV, 1999) and Appendix VI of the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008), the ultimate goal of transport analysis is to develop stochastic predictions of a contaminant boundary at a specified level of uncertainty. However, because of the significant uncertainty of the model results, the primary goal of this report was modified through mutual agreement between the DOE and the State of Nevada to assess the primary model components that contribute to this uncertainty and to postpone defining the contaminant boundary until additional model refinement is completed. Therefore, the role of this analysis has been to understand the behavior of radionuclide migration in the Pahute Mesa (PM) Corrective Action Unit (CAU) model and to define, both qualitatively and quantitatively, the sensitivity of such behavior to (flow) model conceptualization and (flow and transport) parameterization.

  1. Development and exemplification of a model for Teacher Assessment in Primary Science

    Science.gov (United States)

    Davies, D. J.; Earle, S.; McMahon, K.; Howe, A.; Collier, C.

    2017-09-01

    The Teacher Assessment in Primary Science project is funded by the Primary Science Teaching Trust and based at Bath Spa University. The study aims to develop a whole-school model of valid, reliable and manageable teacher assessment to inform practice and make a positive impact on primary-aged children's learning in science. The model is based on a data-flow 'pyramid' (analogous to the flow of energy through an ecosystem), whereby the rich formative assessment evidence gathered in the classroom is summarised for monitoring, reporting and evaluation purposes [Nuffield Foundation. (2012). Developing policy, principles and practice in primary school science assessment. London: Nuffield Foundation]. Using a design-based research (DBR) methodology, the authors worked in collaboration with teachers from project schools and other expert groups to refine, elaborate, validate and operationalise the data-flow 'pyramid' model, resulting in the development of a whole-school self-evaluation tool. In this paper, we argue that a DBR approach to theory-building and school improvement drawing upon teacher expertise has led to the identification, adaptation and successful scaling up of a promising approach to school self-evaluation in relation to assessment in science.

  2. The flow field investigations of no load conditions in axial flow fixed-blade turbine

    Science.gov (United States)

    Yang, J.; Gao, L.; Wang, Z. W.; Zhou, X. Z.; Xu, H. X.

    2014-03-01

    During the start-up process, the strong instabilities happened at no load operation in a low head axial flow fixed-blade turbine, with strong pressure pulsation and vibration. The rated speed can not reach until guide vane opening to some extent, and stable operation could not be maintained under the rated speed at some head, which had a negative impact on the grid-connected operation of the unit. In order to find the reason of this phenomenon, the unsteady flow field of the whole flow passage at no load conditions was carried out to analyze the detailed fluid field characteristics including the pressure pulsation and force imposed on the runner under three typical heads. The main hydraulic cause of no load conditions instability was described. It is recommended that the power station should try to reduce the no-load running time and go into the high load operation as soon as possible when connected to grid at the rated head. Following the recommendations, the plant operation practice proved the unstable degree of the unit was reduced greatly during start up and connect to the power grid.

  3. Dynamic reliability networks with self-healing units

    International Nuclear Information System (INIS)

    Jenab, K.; Seyed Hosseini, S.M.; Dhillon, B.S.

    2008-01-01

    This paper presents an analytical approach for dynamic reliability networks used for the failure limit strategy in maintenance optimization. The proposed approach utilizes the moment generating function (MGF) and the flow-graph concept to depict the functional and reliability diagrams of the system comprised of series, parallel or mix configuration of self-healing units. The self-healing unit is featured by the embedded failure detection and recovery mechanisms presented by self-loop in flow-graph networks. The newly developed analytical approach provides the probability of the system failure and time-to-failure data i.e., mean and standard deviation time-to-failure used for maintenance optimization

  4. Multiplex flow cytometry barcoding and antibody arrays identify surface antigen profiles of primary and metastatic colon cancer cell lines.

    Directory of Open Access Journals (Sweden)

    Kumar Sukhdeo

    Full Text Available Colon cancer is a deadly disease affecting millions of people worldwide. Current treatment challenges include management of disease burden as well as improvements in detection and targeting of tumor cells. To identify disease state-specific surface antigen signatures, we combined fluorescent cell barcoding with high-throughput flow cytometric profiling of primary and metastatic colon cancer lines (SW480, SW620, and HCT116. Our multiplexed technique offers improvements over conventional methods by permitting the simultaneous and rapid screening of cancer cells with reduced effort and cost. The method uses a protein-level analysis with commercially available antibodies on live cells with intact epitopes to detect potential tumor-specific targets that can be further investigated for their clinical utility. Multiplexed antibody arrays can easily be applied to other tumor types or pathologies for discovery-based approaches to target identification.

  5. Bio-inspired multi-mode optic flow sensors for micro air vehicles

    Science.gov (United States)

    Park, Seokjun; Choi, Jaehyuk; Cho, Jihyun; Yoon, Euisik

    2013-06-01

    Monitoring wide-field surrounding information is essential for vision-based autonomous navigation in micro-air-vehicles (MAV). Our image-cube (iCube) module, which consists of multiple sensors that are facing different angles in 3-D space, can be applied to the wide-field of view optic flows estimation (μ-Compound eyes) and to attitude control (μ- Ocelli) in the Micro Autonomous Systems and Technology (MAST) platforms. In this paper, we report an analog/digital (A/D) mixed-mode optic-flow sensor, which generates both optic flows and normal images in different modes for μ- Compound eyes and μ-Ocelli applications. The sensor employs a time-stamp based optic flow algorithm which is modified from the conventional EMD (Elementary Motion Detector) algorithm to give an optimum partitioning of hardware blocks in analog and digital domains as well as adequate allocation of pixel-level, column-parallel, and chip-level signal processing. Temporal filtering, which may require huge hardware resources if implemented in digital domain, is remained in a pixel-level analog processing unit. The rest of the blocks, including feature detection and timestamp latching, are implemented using digital circuits in a column-parallel processing unit. Finally, time-stamp information is decoded into velocity from look-up tables, multiplications, and simple subtraction circuits in a chip-level processing unit, thus significantly reducing core digital processing power consumption. In the normal image mode, the sensor generates 8-b digital images using single slope ADCs in the column unit. In the optic flow mode, the sensor estimates 8-b 1-D optic flows from the integrated mixed-mode algorithm core and 2-D optic flows with an external timestamp processing, respectively.

  6. 21 CFR 870.4300 - Cardiopulmonary bypass gas control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass gas control unit. 870.4300... bypass gas control unit. (a) Identification. A cardiopulmonary bypass gas control unit is a device used to control and measure the flow of gas into the oxygenator. The device is calibrated for a specific...

  7. The Effect of the Treatment with Heated Humidified High-Flow Nasal Cannula on Neonatal Respiratory Distress Syndrome in China: A Single-Center Experience

    Directory of Open Access Journals (Sweden)

    Ge Zheng

    2017-01-01

    Full Text Available Background. Noninvasive respiratory support is considered the optimal method of providing assistance to preterm babies with breathing problems, including nasal continuous positive airway pressure (NCPAP and humidified high flow nasal cannula (HHHFNC. The evidence of the efficacy and safety of HHHFNC used as the primary respiratory support for respiratory distress syndrome (RDS is insufficient in low- and middle-income countries. Objective. To investigate the effect of heated humidified high flow nasal cannula on neonatal respiratory distress syndrome compared with nasal continuous positive airway pressure. Methods. An observational cross-sectional study was performed at a tertiary neonatal intensive care unit in suburban Wenzhou, China, in the period between January 2014 and December 2015. Results. A total of 128 infants were enrolled in the study: 65 in the HHHFNC group and 63 in the NCPAP group. The respiratory support with HHHFNC was similar to that with NCPAP with regard to the primary outcome. There is no significant difference between two groups in secondary outcomes. Comparing with NCPAP group, the incidence of nasal damage was lower in HHHFNC group. Conclusions. HHHFNC is an effective and well-tolerated strategy as the primary treatment of mild to moderate RDS in preterm infants older than 28 weeks of GA.

  8. Primary care and health reform in New Zealand.

    Science.gov (United States)

    Grant, C C; Forrest, C B; Starfield, B

    1997-02-14

    (1) To describe New Zealand's primary care system (2) to compare New Zealand to other Anglo-American members of the OECD with respect to the adequacy of primary care, and (3) to assess the cost-efficiency and effectiveness of New Zealand's system by comparing health spending and health indicators relevant to primary care. A cross-national comparison of primary care, health spending and health indicators in New Zealand, Australia, Canada, the United Kingdom and the United States of America. Main outcome measures were health spending measured in purchasing power parties. Health indicators: mean life expectancy in years, years of potential life lost and infant mortality rates. New Zealand's primary care system ranked below the UK, above the USA and similar to Canada and Australia. Favourable characteristics of New Zealand's primary care system were the use of generalists as the predominant type of practitioner and the low proportion of active physicians who were specialists. Compared to the other countries, New Zealand scored poorly for financial that are necessary for the practise of good primary care. New Zealand and the UK had the lowest spending per capita on health care. New Zealand and the USA scored lowest for all three of the health care indicators. The quality of primary care in New Zealand is limited by barriers to access to care and the intermediate level of practise characteristics essential to primary care. Compared to other AngloAmerican OECD nations, New Zealand has relatively low levels of national health expenditure. In order to improve the quality of primary care, future reform should aim to facilitate access to care, increase the gatekeeping role of primary care physicians, and promote the practise characteristics essential to primary care.

  9. Characteristics of physical activity programs in the Brazilian primary health care system

    Directory of Open Access Journals (Sweden)

    Grace Angélica de Oliveira Gomes

    2014-10-01

    Full Text Available The aim of this study was to describe the characteristics of programs that promote physical activity in the public primary care system by region of Brazil, subject to the presence or absence of multidisciplinary primary care teams (NASF. We conducted a cross sectional and population-based telephone survey of the health unit coordinators from 1,251 health care units. Coordinators were asked about the presence and characteristics of physical activity programs. Four out of ten health units reported having a physical activity intervention program, the most common involving walking groups. Most of the activities were performed in the morning, once or twice a week, and in sessions of 30 minutes or more. Physical education professionals were primarily responsible for directing the activities. Interventions occurred in the health unit itself or in adjacent community spaces. In general, these characteristics were similar between units with or without NASF, but varied substantially across regions. These findings will guide future physical activity policies and programs within primary care in Brazil.

  10. Transition to turbulence and noise radiation in heated coaxial jet flows

    Energy Technology Data Exchange (ETDEWEB)

    Gloor, Michael, E-mail: gloor@ifd.mavt.ethz.ch; Bühler, Stefan; Kleiser, Leonhard [Institute of Fluid Dynamics, ETH Zurich, 8092 Zurich (Switzerland)

    2016-04-15

    Laminar-turbulent transition and noise radiation of a parametrized set of subsonic coaxial jet flows with a hot primary (core) stream are investigated numerically by Large-Eddy Simulation (LES) and direct noise computation. This study extends our previous research on local linear stability of heated coaxial jet flows by analyzing the nonlinear evolution of initially laminar flows disturbed by a superposition of small-amplitude unstable eigenmodes. First, a baseline configuration is studied to shed light on the flow dynamics of coaxial jet flows. Subsequently, LESs are performed for a range of Mach and Reynolds numbers to systematically analyze the influences of the temperature and the velocity ratios between the primary and the secondary (bypass) stream. The results provide a basis for a detailed analysis of fundamental flow-acoustic phenomena in the considered heated coaxial jet flows. Increasing the primary-jet temperature leads to an increase of fluctuation levels and to an amplification of far-field noise, especially at low frequencies. Strong mixing between the cold bypass stream and the hot primary stream as well as the intermittent character of the flow field at the end of the potential core lead to a pronounced noise radiation at an aft angle of approximately 35{sup ∘}. The velocity ratio strongly affects the shear-layer development and therefore also the noise generation mechanisms. Increasing the secondary-stream velocity amplifies the dominance of outer shear-layer perturbations while the disturbance growth rates in the inner shear layer decrease. Already for r{sub mic} > 40R{sub 1}, where r{sub mic} is the distance from the end of the potential core and R{sub 1} is the core-jet radius, a perfect 1/r{sub mic} decay of the sound pressure amplitudes is observed. The potential-core length increases for higher secondary-stream velocities which leads to a shift of the center of the dominant acoustic radiation in the downstream direction.

  11. Improving the primary school science learning unit about force and motion through lesson study

    Science.gov (United States)

    Phaikhumnam, Wuttichai; Yuenyong, Chokchai

    2018-01-01

    The study aimed to develop primary school science lesson plan based on inquiry cycle (5Es) through lesson study. The study focused on the development of 4 primary school science lesson plans of force and motion for Grade 3 students in KKU Demonstration Primary School (Suksasart), first semester of 2015 academic year. The methodology is mixed method. The Inthaprasitha (2010) lesson study cycle was implemented in group of KKU Demonstration Primary School. Instruments of reflection of lesson plan developing included participant observation, meeting and reflection report, lesson plan and other document. The instruments of examining students' learning include classroom observation and achievement test. Data was categorized from these instruments to find the issues of changing and improving the good lesson plan of Thai primary school science learning. The findings revealed that teachers could develop the lesson plans through lesson study. The issues of changing and improving were disused by considering on engaging students related to societal issues, students' prior knowledge, scientific concepts for primary school students, and what they learned from their changing. It indicated that the Lesson Study allowed primary school science teachers to share ideas and develop ideas to improve the lesson. The study may have implications for Thai science teacher education through Lesson Study.

  12. Investigation of vertical slug flow with advanced two-phase flow instrumentation

    International Nuclear Information System (INIS)

    Mi, Y.; Ishii, M.; Tsoukalas, L.H.

    2001-01-01

    Extensive experiments of vertical slug flow were carried out with an electromagnetic flowmeter and an impedance void-meter in an air-water two-phase experimental loop. The basic principles of these instruments in vertical slug flow measurements are discussed. Time series of the liquid velocity and the impedance were separated into two parts corresponding to the Taylor bubble and the liquid slug. Characteristics of slug flow, such as the void fractions, probabilities and lengths of the Taylor bubble and liquid slug, slug unit velocity, area-averaged liquid velocity, and liquid film velocity of the Taylor bubble tail, etc., were obtained. For the first time, the area-averaged liquid velocity of slug flow was revealed by the electromagnetic flowmeter. It is realized that the void fraction of the liquid slug is determined by the turbulent intensity due to the relative liquid motion between the Taylor bubble tail region and its wake region. A correlation of the void fraction of the liquid slug is developed based on experimental results obtained from a test section with 50.8 mm i.d. The results of this study suggest a promising improvement in understanding of vertical slug flow

  13. Primary volcanic structures from a type section of Deccan Trap flows ...

    Indian Academy of Sciences (India)

    Swanson 1967; Macdonald 1967; Long and Wood. Keywords. Deccan Traps; lava flows; volcanism; isotherm; cooling history. J. Earth Syst. Sci. 115, No. ...... Kilauea Volcanic island of Hawaii; J. Geophys. Res. 103. 27,303–27,323. Lightfoot ...

  14. TRAINING OF THE STATE PRESIDENT'S UNIT

    African Journals Online (AJOL)

    The primary function of the State President's Unit is to protect the head of state - not his person as is generally believed, but his authority over the state. Ironically, the ceremonial performances of the State President's Unit lead people to believe that they are only capable of doing drill exer- cises. However, upon investigating.

  15. Regional cerebral blood flow in childhood headache

    International Nuclear Information System (INIS)

    Roach, E.S.; Stump, D.A.

    1989-01-01

    Regional cerebral blood flow (rCBF) was measured in 16 cranial regions in 23 children and adolescents with frequent headaches using the non-invasive Xenon-133 inhalation technique. Blood flow response to 5% carbon dioxide (CO2) was also determined in 21 patients, while response to 50% oxygen was measured in the two patients with hemoglobinopathy. Included were 10 patients with a clinical diagnosis of migraine, 4 with musculoskeletal headaches, and 3 with features of both types. Also studied were 2 patients with primary thrombocythemia, 2 patients with hemoglobinopathy and headaches, 1 patient with polycythemia, and 1 with headaches following trauma. With two exceptions, rCBF determinations were done during an asymptomatic period. Baseline rCBF values tended to be higher in these young patients than in young adults done in our laboratory. Localized reduction in the expected blood flow surge after CO2 inhalation, most often noted posteriorly, was seen in 8 of the 13 vascular headaches, but in none of the musculoskeletal headache group. Both patients with primary thrombocythemia had normal baseline flow values and altered responsiveness to CO2 similar to that seen in migraineurs; thus, the frequently reported headache and transient neurologic signs with primary thrombocythemia are probably not due to microvascular obstruction as previously suggested. These data support the concept of pediatric migraine as a disorder of vasomotor function and also add to our knowledge of normal rCBF values in younger patients. Demonstration of altered vasomotor reactivity to CO2 could prove helpful in children whose headache is atypical

  16. Quality assurance for primary batteries. Qualitaetssicherung fuer Primaerbatterien

    Energy Technology Data Exchange (ETDEWEB)

    Ruedinger, G [Varta AG, Ellwangen (Germany, F.R.)

    1989-11-01

    Apart from a few applications in tube sets, the use of primary batteries was limited until well into the fifties to the current supply of lighting units, predominantly of flashlights. Only with the invention of the transistor and of integrated circuits, the primary battery took an important place among electric components. As a consequence, this component had to meet much different requirements. In order to ensure the quality of an article produced in enormous quantities - several hundred million units per year with a great variety of types, with nine different systems and of approx. 100 different types - it became indispensable to set up a well equipped quality assurance system. (orig.).

  17. Primary atmospheric oxidation mechanism for toluene.

    Science.gov (United States)

    Baltaretu, Cristian O; Lichtman, Eben I; Hadler, Amelia B; Elrod, Matthew J

    2009-01-08

    The products of the primary OH-initiated oxidation of toluene were investigated using the turbulent flow chemical ionization mass spectrometry technique at temperatures ranging from 228 to 298 K. A major dienedial-producing pathway was detected for the first time for toluene oxidation, and glyoxal and methylglyoxal were found to be minor primary oxidation products. The results suggest that secondary oxidation processes involving dienedial and epoxide primary products are likely responsible for previous observations of glyoxal and methylglyoxal products from toluene oxidation. Because the dienedial-producing pathway is a null cycle for tropospheric ozone production and glyoxal and methylglyoxal are important secondary organic aerosol precursors, these new findings have important implications for the modeling of toluene oxidation in the atmosphere.

  18. [Technical efficiency assessment of public primary care providers in the Basque Country (Spain), 2010-2013].

    Science.gov (United States)

    Cordero, José Manuel; Nuño-Solinís, Roberto; Orueta, Juan F; Polo, Cristina; Del Río-Cámara, Mario; Alonso-Morán, Edurne

    2016-01-01

    To evaluate the technical efficiency of primary care units operating in the Basque Health Service during the period 2010-2013, corresponding to the implementation of a care integration strategy by health authorities. This study included 11 of the 12 primary care units in the Basque Health Service during the period 2010-2013. Data envelopment analysis (DEA) was used to assess the technical efficiency of the units. In particular, we applied the extension DEA windows to analyse all units as if they were in a single period (33 observations) as well as a conditional model, which allowed incorporation of the effect of the characteristics of the population covered. The outputs considered were a quality index based on fulfilment of different requirements related to primary care delivery and the rate of avoidable hospitalizations (treated as an undesirable output). The inputs used were the number of physicians, the number of nurses and the costs of prescriptions. The morbidity index was included as an exogenous variable. The results showed that the efficiency of all the units improved during the study period. However, this improvement was not greater in the units incorporated in the integrated healthcare organisation. In a context of global transformation of care delivery in the Basque country in the study period, primary care units increased their efficiency. However, this effect was not larger in vertically integrated primary care providers. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.

  19. Primary care and addiction treatment: lessons learned from building bridges across traditions.

    Science.gov (United States)

    Stanley, A H

    1999-01-01

    A primary care unit combined with residential addiction treatment allows patients with addictive disease and chronic medical or psychiatric problems to successfully complete the treatment. These are patients who would otherwise fail treatment or fail to be considered candidates for treatment. Health care providers should have a background in primary care and have the potential to respond professionally to clinical problems in behavioral medicine. Ongoing professional training and statistical quality management principles can maintain morale and productivity. Health education is an integral part of primary care. The costs of such concurrent care when viewed in the context of the high societal and economic costs of untreated addictive disease and untreated chronic medical problems are low. The principles used to develop this primary care unit can be used to develop health care units for other underserved populations. These principles include identification of specific health care priorities and continuity of rapport with the target population and with addiction treatment staff.

  20. A topological method for vortex identification in turbulent flows

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Qiang; Chen, Huai; Li, Danxun [State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084 (China); Chen, Qigang, E-mail: lidx@mail.tsinghua.edu.cn [School of Civil Engineering, Beijing Jiaotong University, Beijing 100044 (China)

    2017-02-15

    We present a novel vortex identification method based on structured vorticity ( ω {sub s}) of the direction field of flow (velocity vectors set to unit magnitude). As a direct measure of streamline curvature is insensitive to vortex strength, ω {sub s} is effective in detecting vortices of various strengths. The effectiveness has been tested against both analytical flows (pure shear flow, Oseen vortex flow, strong outward spiraling motion, straining flow, Taylor–Green flow) and experimental flows (closed cavity flow, closed and open channel flow). Comparison of the new method with the swirling-strength method indicates that the new method shows promise as being a simple and effective criterion for vortex identification. (paper)

  1. Completion Report for Well ER-3-3 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Wurtz, Jeffrey [Navarro, Las Vegas, NV (United States); Rehfeldt, Ken [Navarro, Las Vegas, NV (United States)

    2017-04-01

    Well ER-3-3 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled and completed from February 21 to March 15, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Yucca Flat/Climax Mine Corrective Action Unit (CAU) 97. The primary purpose of the well was to collect hydrogeologic data to assist in validating concepts of the flow system within the Yucca Flat/Climax Mine CAU, and to test for potential radionuclides in groundwater from the WAGTAIL (U3an) underground test.

  2. The internal flow pattern analysis of a tidal power turbine operating on bidirectional generation-pumping

    International Nuclear Information System (INIS)

    Luo, Y Y; Xiao, Y X; Wang, Z W

    2013-01-01

    Using tidal energy can reduce environment pollution, save conventional energy and improve energy structure, hence it presents great advantage and is developing potential. Influenced by flood tide and low tide, a fully functional tidal power station needs to experience six operating modes, including bidirectional generation, pumping and sluice; the internal unsteady flow pattern and dynamic characters are very complicated. Based on a bidirectional tidal generator unit, three-dimensional unsteady flows in the flow path were calculated for four typical operating conditions with the pressure pulsation characteristics analyzed. According to the numerical results, the internal flow characteristics in the flow path were discussed. The influence of gravity to the hydraulic performance and flow characteristics were analysed. The results provide a theoretical analysis method of the hydraulic optimization design of the same type unit as well as a direction for stable operation and optimal scheduling of existing tidal power unit

  3. Interview and questionnaire guide: Quantification of food losses and waste in primary production

    DEFF Research Database (Denmark)

    Svanes, Erik; Hartikainen, Hanna; Mogensen, Lisbeth

    production in the Nordic countries. Other aims were to estimate the amount of side flow and to gain knowledge about the reasons behind it, how it can be reduced, how it is treated and how it can be better utilized.This guide contains a catalogue of questions that may be used for interviews and questionnaires...... with primary producers and other stakeholders within primary production. It also contains the justification behind the questions and some tips on how to conduct interviews.......This interview guide was developed within the Nordic project “Food losses and waste in primary production” (Franke et al. 2016). One of the main purposes of the project was to test research methods for the quantification of food losses and waste (in the project called 'side flow') from primary...

  4. First status report on regional ground-water flow modeling for Vacherie Dome, Louisiana

    International Nuclear Information System (INIS)

    1986-07-01

    Regional ground-water flow within the principal geohydrologic units in the vicinity of Vacherie Dome, Louisiana is evaluated by developing a conceptual model of the flow regime within these units and testing the model using a three-dimensional, finite-difference flow code (SWENT). Semiquantitative sensitivity analyses (a limited parametric study) are conducted to define the system responses to changes in the conceptual model, particularly in regard to the geohydrologic properties. All steps leading to the final results and conclusions are incorporated in this report. The available data utilized in this study are summarized. The conceptual model is defined in terms of the areal and vertical averaging of lithologic units, aquifer properties, and hydrologic boundary conditions. The simulated ground-water flow fields are described with potentiometric surfaces, areas of upward and downward flow across aquitards, tables summarizing the horizontal and vertical volumetric flows through the principal units, ground-water travel times and paths, and Darcy velocities within specified finite-difference blocks. The reported work is the first stage of an ongoing evaluation of Vacherie Dome as a potential repository for high-level radioactive wastes. The results and conclusions should thus be considered preliminary and subject to modification with the collection of additional data. However, the report does provide a useful basis for describing the sensitivity of the conceptualization of ground-water flow to parameterization and, to a lesser extent, the uncertainties in the present conceptualization. 34 refs., 57 figs., 19 tabs

  5. Effects of SMES units on power system stability

    International Nuclear Information System (INIS)

    Byerly, R.T.; Juves, J.A.

    1980-01-01

    A mathematical model suitable for representing SMES units in power system stability studies has been developed and incorporated into an existing large-scale stability program. Demonstration studies have been performed which emphasize the use of SMES units to improve the damping of oscillations associated with synchronizing power flow among generators. The capability exists to conduct stability studies of large systems which include SMES units

  6. Phase II Contaminant Transport Parameters for the Groundwater Flow and Contaminant Transport Model of Corrective Action Unit 98: Frenchman Flat, Nye County, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    DeNovio, Nicole M.; Bryant, Nathan; King, Chrissi B.; Bhark, Eric; Drellack, Sigmund L.; Pickens, John F.; Farnham, Irene; Brooks, Keely M.; Reimus, Paul; Aly, Alaa

    2005-04-01

    This report documents pertinent transport data and data analyses as part of the Phase II Corrective Action Investigation (CAI) for Frenchman Flat (FF) Corrective Action Unit (CAU) 98. The purpose of this data compilation and related analyses is to provide the primary reference to support parameterization of the Phase II FF CAU transport model.

  7. Nature and extent of lava-flow aquifers beneath Pahute Mesa, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Prothro, L.B.; Drellack, S.L. Jr.

    1997-09-01

    Work is currently underway within the Underground Test Area subproject of the US Department of Energy/Nevada Operations Office Environmental Restoration Program to develop corrective action plans in support of the overall corrective action strategy for the Nevada Test Site as established in the Federal Facility Agreement and Consent Order (FFACO, 1996). A closure plan is currently being developed for Pahute Mesa, which has been identified in the FFACO as consisting of the Western and Central Pahute Mesa Corrective Action Units. Part of this effort requires that hydrogeologic data be compiled for inclusion in a regional model that will be used to predict a contaminant boundary for these Corrective Action Units. Hydrogeologic maps have been prepared for use in the model to define the nature and extent of aquifers and confining units that might influence the flow of contaminated groundwater from underground nuclear tests conducted at Pahute Mesa. Much of the groundwater flow beneath Pahute Mesa occurs within lava-flow aquifers. An understanding of the distribution and hydraulic character of these important hydrogeologic units is necessary to accurately model groundwater flow beneath Pahute Mesa. This report summarizes the results of a study by Bechtel Nevada geologists to better define the hydrogeology of lava-flow aquifers at Pahute Mesa. The purpose of this study was twofold: (1) aid in the development of the hydrostratigraphic framework for Pahute Mesa, and (2) provide information on the distribution and hydraulic character of lava-flow aquifers beneath Pahute Mesa for more accurate computer modeling of the Western and Central Pahute Mesa Corrective Action Units.

  8. Computational study of duct and pipe flows using the method of pseudocompressibility

    Science.gov (United States)

    Williams, Robert W.

    1991-01-01

    A viscous, three-dimensional, incompressible, Navier-Stokes Computational Fluid Dynamics code employing pseudocompressibility is used for the prediction of laminar primary and secondary flows in two 90-degree bends of constant cross section. Under study are a square cross section duct bend with 2.3 radius ratio and a round cross section pipe bend with 2.8 radius ratio. Sensitivity of predicted primary and secondary flow to inlet boundary conditions, grid resolution, and code convergence is investigated. Contour and velocity versus spanwise coordinate plots comparing prediction to experimental data flow components are shown at several streamwise stations before, within, and after the duct and pipe bends. Discussion includes secondary flow physics, computational method, computational requirements, grid dependence, and convergence rates.

  9. A model of hydraulic interactions in liver parenchyma as forces behind the intrahepatic bile flow.

    Science.gov (United States)

    Kurbel, S; Kurbel, B; Dmitrovic, B; Wagner, J

    2001-05-01

    The small diameters of bile canaliculi and interlobular bile ducts make it hard to attribute the bile flow solely to the process of secretion. In the model liver within its capsule is considered a limited space in which volume expansions of one part are possible only through the shrinking of other parts. The liver capsule allows only very slow volume changes. The rate of blood flow through the sinusoides is governed by the Poisseuill-Hagen law. The model is based on a concept of circulatory liver units. A unit would contain a group of acini sharing the same conditions of arterial flow. We can imagine them as an acinar group behind the last pressure reducer on one arterial branch. Acini from neighboring units compose liver lobules and drain through the same central venule. One lobule can contain acini from several neighboring circulatory units. The perfusion cycle in one unit begins with a transient tide in the arterial flow, governed by local mediators. Corresponding acini expand, grabbing the space by compressing their neighbors in the same lobules. Vascular resistance is reduced in dilated and increased in compressed acini. Portal blood flows through the dilated acini, bypassing the compressed neighbors. The cycle ends when the portal tide slowly diminishes and acinar volume is back on the interphase value until the new perfusion cycle is started in another circulatory unit. Each cycle probably takes minutes to complete. Increased pressures both in dilated and in compressed acini force the bile to move from acinar canalicules. Both up and down changes in acinar volume might force the acinar biliary flow. In cases of arterial vasoconstriction, increased activity of vasoactive substances would keep most of the circulatory units in the interphase and increased liver resistance can be expected. Liver fibrosis makes all acini to be of fixed volume and result in increased resistance. Because of that, low pressure portal flow would be more compromised, as reported. In

  10. Fatigue of LMFBR piping due to flow stratification

    International Nuclear Information System (INIS)

    Woodward, W.S.

    1983-01-01

    Flow stratification due to reverse flow was simulated in a 1/5-scale water model of a LMFBR primary pipe loop. The stratified flow was observed to have a dynamic interface region which oscillated in a wave pattern. The behavior of the interface was characterized in terms of location, local temperature fluctuation and duration for various reverse flow conditions. A structural assessment was performed to determine the effects of stratified flow on the fatigue life of the pipe. Both the static and dynamic aspects of flow stratification were examined. The dynamic interface produces thermal striping on the inside of the pipe wall which is shown to have the most deleterious effect on the pipe wall and produce significant fatigue damage relative to a static interface

  11. Fatigue of LMFBR piping due to flow stratification

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, W.S.

    1983-01-01

    Flow stratification due to reverse flow was simulated in a 1/5-scale water model of a LMFBR primary pipe loop. The stratified flow was observed to have a dynamic interface region which oscillated in a wave pattern. The behavior of the interface was characterized in terms of location, local temperature fluctuation and duration for various reverse flow conditions. A structural assessment was performed to determine the effects of stratified flow on the fatigue life of the pipe. Both the static and dynamic aspects of flow stratification were examined. The dynamic interface produces thermal striping on the inside of the pipe wall which is shown to have the most deleterious effect on the pipe wall and produce significant fatigue damage relative to a static interface.

  12. Power flow control based solely on slow feedback loop for heart pump applications.

    Science.gov (United States)

    Wang, Bob; Hu, Aiguo Patrick; Budgett, David

    2012-06-01

    This paper proposes a new control method for regulating power flow via transcutaneous energy transfer (TET) for implantable heart pumps. Previous work on power flow controller requires a fast feedback loop that needs additional switching devices and resonant capacitors to be added to the primary converter. The proposed power flow controller eliminates these additional components, and it relies solely on a slow feedback loop to directly drive the primary converter to meet the heart pump power demand and ensure zero voltage switching. A controlled change in switching frequency varies the resonant tank shorting period of a current-fed push-pull resonant converter, thus changing the magnitude of the primary resonant voltage, as well as the tuning between primary and secondary resonant tanks. The proposed controller has been implemented successfully using an analogue circuit and has reached an end-to-end power efficiency of 79.6% at 10 W with a switching frequency regulation range of 149.3 kHz to 182.2 kHz.

  13. HTGR-GT primary coolant transient resulting from postulated turbine deblading

    International Nuclear Information System (INIS)

    Cadwallader, G.J.; Deremer, R.K.

    1980-11-01

    The turbomachine is located within the primary coolant system of a nuclear closed cycle gas turbine plant (HTGR-GT). The deblading of the turbine can cause a rapid pressure equilibration transient that generates significant loads on other components in the system. Prediction of and design for this transient are important aspects of assuring the safety of the HTGR-GT. This paper describes the adaptation and use of the RATSAM program to analyze the rapid fluid transient throughout the primary coolant system during a spectrum of turbine deblading events. Included are discussions of (1) specific modifications and improvements to the basic RATSAM program, which is also briefly described; (2) typical results showing the expansion wave moving upstream from the debladed turbine through the primary coolant system; and (3) the effect on the transient results of different plenum volumes, flow resistances, times to deblade, and geometries that can choke the flow

  14. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic Conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Science.gov (United States)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-01-01

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  15. Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.

    2010-02-12

    Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative

  16. Evaluation on the imaging of the bronchial blood flow using nuclear angiocardiography

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Hirayama, Jiro; Kanai, Hisakata; Kobayashi, Toshio; Handa, Kenjiro

    1979-01-01

    Nuclear angiocardiography with sup(99m)TcO 4 - was performed for the purpose of the delineation of the systemic perfusion in various lung diseases, using a scintillation camera with a digital minicomputer system. The images of the bronchial blood flow were obtained in cases with primary lung cancer, pulmonary tuberculosis, lung abscess, bronchiectasis and chronic bronchitis. The fair images of the bronchial blood flow were taken in cases of peripheral type, adenocarcinoma and primary foci of atelectatic type in primary lung cancer. The grade of delineation of the bronchial blood flow and vascularity of bronchial artery in foci of primary lung cancer were correlative to the grade of accumulation of 197 HgCl 2 , respectively. The joint use of nuclear angiocardiography and other imagings such as tumor or perfusion one was useful for evaluation of the pulmonary and systemic circulation, and that made isotope diagnosis of primary lung cancer more reliable too. The image as a isocount map extracted out of the image of 197 HgCl 2 or sup(99m)Tc-MAA, was superimposed to the brightness image of the nuclear angiocardiogram (aortic phase). This image superimposition methods were valuable to improve anatomic orientation of the nuclear angiocardiogram. The delineation of the bronchial blood flow on the subtraction image, which obtained from the two time-different images in aortic phase of the nuclear angiocardiogram, was better than that of the original images. (author)

  17. Continuous flow nitration in miniaturized devices

    Directory of Open Access Journals (Sweden)

    Amol A. Kulkarni

    2014-02-01

    Full Text Available This review highlights the state of the art in the field of continuous flow nitration with miniaturized devices. Although nitration has been one of the oldest and most important unit reactions, the advent of miniaturized devices has paved the way for new opportunities to reconsider the conventional approach for exothermic and selectivity sensitive nitration reactions. Four different approaches to flow nitration with microreactors are presented herein and discussed in view of their advantages, limitations and applicability of the information towards scale-up. Selected recent patents that disclose scale-up methodologies for continuous flow nitration are also briefly reviewed.

  18. Risk of cancer in retransplants compared to primary kidney transplants in the United States.

    Science.gov (United States)

    Kalil, Roberto S; Lynch, Charles F; Engels, Eric A

    2015-10-01

    Recipients of kidney transplantation have elevated risk of developing cancer. There are limited data on cancer risk in recipients of kidney retransplantation. We used data from the Transplant Cancer Match Study, which links the U.S. transplant registry with 15 cancer registries. Cancer incidence in recipients of kidney retransplantation and primary kidney transplants was compared utilizing Poisson regression, adjusting for demographic and medical characteristics. We assessed 109 224 primary recipients and 6621 retransplants. Compared to primary recipients, retransplants were younger (median age 40 vs. 46 yr), had higher PRA, and more often received induction with polyclonal antibodies (43% vs. 25%). A total of 5757 cancers were observed in primary recipients and 245 in retransplants. Overall cancer risk was similar in retransplants compared with primary recipients (incidence rate ratio [IRR] 1.06, 95% CI 0.93-1.20, adjusted for age, gender, race/ethnicity, PRA, and use of polyclonal induction). However, renal cell carcinoma (RCC) occurred in excess among retransplants (adjusted IRR 2.03, 95% CI 1.45-2.77), based on 514 cases in primary recipients and 43 cases in retransplants. Overall cancer risk did not differ in retransplants compared to primary recipients. Increased risk of RCC may be explained by the presence of acquired cystic kidney disease, which is more likely to develop with additional time with kidney disease and time spent on dialysis waiting for retransplantation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Primary care in the United States: practice-based innovations and factors that influence adoption.

    Science.gov (United States)

    Goldberg, Debora Goetz

    2012-01-01

    This study aims to explore the use of specific innovations in primary care practices. The research seeks to examine whether a relationship exists between environmental factors and organizational characteristics and the level of innovation in primary care practices in Virginia. The study utilized multiple secondary data sets and an organizational survey of primary care practices to define the external environment and the level of innovation. Institutional theory was used to explain the connection between innovations in primary care practices and institutional forces within the environment. Resource dependency theory was used to explain motivators for change based on a dependence on scarce financial, human, and information resources. Results show a positive association between organizational size, organizational relationships, and stakeholder expectations on the level of innovation. A negative association was found between competition and the level of innovation. No relationship was found between degree of Medicare and managed care penetration and innovation, nor between knowledge of, and difficulty complying with, payer organization requirements and innovation. Primary care physician practices exist in a market-driven environment characterized by high pressure from regulatory sources, decreasing reimbursement levels, increasing rate of change in technologies, and increasing patient and community expectations. This study contributes new information on the relationship between organizational characteristics, the external environment and specific innovations in primary care practices. Information on the contributing factors to innovation in primary care is important for improving delivery of health care services and the ability of these practices to survive.

  20. Three-phase model and power-flow analysis of microgrids and virtual power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kamh, M.Z.; Iravani, R. [Toronto Univ., ON (Canada). Dept. of Electrical and Computer Engineering, Energy Systems Group

    2009-07-01

    A distributed energy resources (DER) unit can be a distributed generation unit, a distributed storage unit, or a hybrid of the two. It can be dispatchable, non-dispatchable or pseudo-dispatchable. A DER unit is connected to the hosting utility directly or via an electronic converter. A three-phase model and power-flow analysis of microgrids and virtual power plants was presented. The presentation discussed DER classification; microgrids and virtual power plants; motivations and goals; and a proposed DER model and power flow approach. Validation and results were also offered. The developed algorithm was implemented in the sequence-component frame using the MATLAB platform. Case studies were offered in order to verify the accuracy of the DER model and the power-flow program. It was concluded that the developed software accommodates different DER configurations and accurately reflects their control strategies. figs.

  1. Exhaust bypass flow control for exhaust heat recovery

    Science.gov (United States)

    Reynolds, Michael G.

    2015-09-22

    An exhaust system for an engine comprises an exhaust heat recovery apparatus configured to receive exhaust gas from the engine and comprises a first flow passage in fluid communication with the exhaust gas and a second flow passage in fluid communication with the exhaust gas. A heat exchanger/energy recovery unit is disposed in the second flow passage and has a working fluid circulating therethrough for exchange of heat from the exhaust gas to the working fluid. A control valve is disposed downstream of the first and the second flow passages in a low temperature region of the exhaust heat recovery apparatus to direct exhaust gas through the first flow passage or the second flow passage.

  2. State space analysis of minimal channel flow

    Energy Technology Data Exchange (ETDEWEB)

    Neelavara, Shreyas Acharya; Duguet, Yohann; Lusseyran, François, E-mail: acharya@limsi.fr [LIMSI-CNRS, Campus Universitaire d’Orsay, Université Paris-Saclay, F-91405 Orsay (France)

    2017-06-15

    Turbulence and edge states are investigated numerically in a plane Poiseuille flow driven by a fixed pressure gradient. Simulations are carried out within the minimal flow unit, a concept introduced by Jiménez and Moin (1991 J . Fluid Mech. 225 213–40) to unravel the dynamics of near-wall structures in the absence of outer large-scale motions. For both turbulent and edge regimes the activity appears to be localised near only one wall at a time, and the long term dynamics features abrupt reversals. The dynamics along one reversal is structured around the transient visit to a subspace of symmetric flow fields. An exact travelling wave solution is found to exist very close to this subspace. Additionally the self-similarity of the asymmetric states is addressed. Contrary to most studies focusing on symmetric solutions, the present study suggests that edge states, when localised near one wall, do not scale in outer units. The current study suggests a composite scaling. (paper)

  3. Development of an ultrasonic flow and temperature measurement system for pressurized water reactors

    International Nuclear Information System (INIS)

    James, R.W.; Lubnow, T.; Baumgart, G.; Ravetti, D.

    1996-01-01

    In U.S. nuclear plants, primary coolant flow and reactor thermal power are calculated from a measurement of feedwater flow to the steam generator combined with knowledge of steam generator heat transfer characteristics nd measurement of hot leg temperature by resistance temperature detectors (RTDs). The calculation of plant thermal output is complicated by an indirect measurement of primary coolant mass flow rate and thermal streaming in the region where hot leg temperature is typically measured. Uncertainty in the thermal output calculation results from uncertainties in steam generator characteristics, in the hot leg temperature due to thermal streaming, and in fouling of venturi nozzles used for feedwater flow measurement. This in turn leads to operation of power plants ar lower levels of efficiency. The Electric Power Research Institute (EPRI) has on ongoing project to develop a prototype system to directly measure primary coolant flow rate and bulk average temperature using ultrasonic transducers externally mounted on the pipe. The topic of this paper is a summary of the project experience in developing this system. The technology being developed in this project is based in part upon previously existing ultrasonic feedwater flow measurement technology developed by MPR Associates and Caldon, Inc EPRI is a non-profit company performing research for U.S. and international electric power utilities. (authors)

  4. Real-time acquisition and display of flow contrast using speckle variance optical coherence tomography in a graphics processing unit.

    Science.gov (United States)

    Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V

    2014-02-01

    In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.

  5. Three-dimensional hydrogeologic framework model for use with a steady-state numerical ground-water flow model of the Death Valley regional flow system, Nevada and California

    International Nuclear Information System (INIS)

    Belcher, W.R.; Faunt, C.C.; D'Agnese, F.A.

    2002-01-01

    The U.S. Geological Survey, in cooperation with the Department of Energy and other Federal, State, and local agencies, is evaluating the hydrogeologic characteristics of the Death Valley regional ground-water flow system. The ground-water flow system covers and area of about 100,000 square kilometers from latitude 35 degrees to 38 degrees 15 minutes North to longitude 115 degrees to 118 degrees West, with the flow system proper comprising about 45,000 square kilometers. The Death Valley regional ground-water flow system is one of the larger flow systems within the Southwestern United States and includes in its boundaries the Nevada Test Site, Yucca Mountain, and much of Death Valley. Part of this study includes the construction of a three-dimensional hydrogeologic framework model to serve as the foundation for the development of a steady-state regional ground-water flow model. The digital framework model provides a computer-based description of the geometry and composition of the hydro geologic units that control regional flow. The framework model of the region was constructed by merging two previous framework models constructed for the Yucca Mountain Project and the Environmental Restoration Program Underground Test Area studies at the Nevada Test Site. The hydrologic characteristics of the region result from a currently arid climate and complex geology. Interbasinal regional ground-water flow occurs through a thick carbonate-rock sequence of Paleozoic age, a locally thick volcanic-rock sequence of Tertiary age, and basin-fill alluvium of Tertiary and Quaternary age. Throughout the system, deep and shallow ground-water flow may be controlled by extensive and pervasive regional and local faults and fractures. The framework model was constructed using data from several sources to define the geometry of the regional hydrogeologic units. These data sources include (1) a 1:250,000-scale hydrogeologic-map compilation of the region; (2) regional-scale geologic cross

  6. Multidisciplinary Simulation Acceleration using Multiple Shared-Memory Graphical Processing Units

    Science.gov (United States)

    Kemal, Jonathan Yashar

    For purposes of optimizing and analyzing turbomachinery and other designs, the unsteady Favre-averaged flow-field differential equations for an ideal compressible gas can be solved in conjunction with the heat conduction equation. We solve all equations using the finite-volume multiple-grid numerical technique, with the dual time-step scheme used for unsteady simulations. Our numerical solver code targets CUDA-capable Graphical Processing Units (GPUs) produced by NVIDIA. Making use of MPI, our solver can run across networked compute notes, where each MPI process can use either a GPU or a Central Processing Unit (CPU) core for primary solver calculations. We use NVIDIA Tesla C2050/C2070 GPUs based on the Fermi architecture, and compare our resulting performance against Intel Zeon X5690 CPUs. Solver routines converted to CUDA typically run about 10 times faster on a GPU for sufficiently dense computational grids. We used a conjugate cylinder computational grid and ran a turbulent steady flow simulation using 4 increasingly dense computational grids. Our densest computational grid is divided into 13 blocks each containing 1033x1033 grid points, for a total of 13.87 million grid points or 1.07 million grid points per domain block. To obtain overall speedups, we compare the execution time of the solver's iteration loop, including all resource intensive GPU-related memory copies. Comparing the performance of 8 GPUs to that of 8 CPUs, we obtain an overall speedup of about 6.0 when using our densest computational grid. This amounts to an 8-GPU simulation running about 39.5 times faster than running than a single-CPU simulation.

  7. Double-trace flows and the swampland

    Science.gov (United States)

    Giombi, Simone; Perlmutter, Eric

    2018-03-01

    We explore the idea that large N, non-supersymmetric conformal field theories with a parametrically large gap to higher spin single-trace operators may be obtained as infrared fixed points of relevant double-trace deformations of superconformal field theories. After recalling the AdS interpretation and some potential pathologies of such flows, we introduce a concrete example that appears to avoid them: the ABJM theory at finite k, deformed by \\int O^2, where O is the superconformal primary in the stress-tensor multiplet. We address its relation to recent conjectures based on weak gravity bounds, and discuss the prospects for a wider class of similarly viable flows. Next, we proceed to analyze the spectrum and correlation functions of the putative IR CFT, to leading non-trivial order in 1 /N. This includes analytic computations of the change under double-trace flow of connected four-point functions of ABJM superconformal primaries; and of the IR anomalous dimensions of infinite classes of double-trace composite operators. These would be the first analytic results for anomalous dimensions of finite-spin composite operators in any large N CFT3 with an Einstein gravity dual.

  8. Methodology and measures for preventing unacceptable flow-accelerated corrosion thinning of pipelines and equipment of NPP power generating units

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.; Lovchev, V. N.; Gutsev, D. F.

    2016-10-01

    Problems of metal flow-accelerated corrosion (FAC) in the pipelines and equipment of the condensate- feeding and wet-steam paths of NPP power-generating units (PGU) are examined. Goals, objectives, and main principles of the methodology for the implementation of an integrated program of AO Concern Rosenergoatom for the prevention of unacceptable FAC thinning and for increasing operational flow-accelerated corrosion resistance of NPP EaP are worded (further the Program). A role is determined and potentialities are shown for the use of Russian software packages in the evaluation and prediction of FAC rate upon solving practical problems for the timely detection of unacceptable FAC thinning in the elements of pipelines and equipment (EaP) of the secondary circuit of NPP PGU. Information is given concerning the structure, properties, and functions of the software systems for plant personnel support in the monitoring and planning of the inservice inspection of FAC thinning elements of pipelines and equipment of the secondary circuit of NPP PGUs, which are created and implemented at some Russian NPPs equipped with VVER-1000, VVER-440, and BN-600 reactors. It is noted that one of the most important practical results of software packages for supporting NPP personnel concerning the issue of flow-accelerated corrosion consists in revealing elements under a hazard of intense local FAC thinning. Examples are given for successful practice at some Russian NPP concerning the use of software systems for supporting the personnel in early detection of secondary-circuit pipeline elements with FAC thinning close to an unacceptable level. Intermediate results of working on the Program are presented and new tasks set in 2012 as a part of the updated program are denoted. The prospects of the developed methods and tools in the scope of the Program measures at the stages of design and construction of NPP PGU are discussed. The main directions of the work on solving the problems of flow

  9. Can Wet Rocky Granular Flows Become Debris Flows Due to Fine Sediment Production by Abrasion?

    Science.gov (United States)

    Arabnia, O.; Sklar, L. S.; Bianchi, G.; Mclaughlin, M. K.

    2015-12-01

    Debris flows are rapid mass movements in which elevated pore pressures are sustained by a viscous fluid matrix with high concentrations of fine sediments. Debris flows may form from coarse-grained wet granular flows as fine sediments are entrained from hillslope and channel material. Here we investigate whether abrasion of the rocks within a granular flow can produce sufficient fine sediments to create debris flows. To test this hypothesis experimentally, we used a set of 4 rotating drums ranging from 0.2 to 4.0 m diameter. Each drum has vanes along the boundary ensure shearing within the flow. Shear rate was varied by changing drum rotational velocity to maintain a constant Froude Number across drums. Initial runs used angular clasts of granodiorite with a tensile strength of 7.6 MPa, with well-sorted coarse particle size distributions linearly scaled with drum radius. The fluid was initially clear water, which rapidly acquired fine-grained wear products. After each 250 m tangential distance, we measured the particle size distributions, and then returned all water and sediment to the drums for subsequent runs. We calculate particle wear rates using statistics of size and mass distributions, and by fitting the Sternberg equation to the rate of mass loss from the size fraction > 2mm. Abundant fine sediments were produced in the experiments, but very little change in the median grain size was detected. This appears to be due to clast rounding, as evidenced by a decrease in the number of stable equilibrium resting points. We find that the growth in the fine sediment concentration in the fluid scales with unit drum power. This relationship can be used to estimate fine sediment production rates in the field. We explore this approach at Inyo Creek, a steep catchment in the Sierra Nevada, California. There, a significant debris flow occurred in July 2013, which originated as a coarse-grained wet granular flow. We use surveys to estimate flow depth and velocity where super

  10. Continuous-Flow Biochips: Technology, Physical Design Methods and Testing

    DEFF Research Database (Denmark)

    Pop, Paul; Araci, Ismail Emre; Chakrabarty, Krishnendu

    2015-01-01

    This article is a tutorial on continuous-flow biochips where the basic building blocks are microchannels, and microvalves, and by combining them, more complex units such as mixers, switches, and multiplexers can be built. It also presents the state of the art in flow-based biochip technology...

  11. Intermittency and transition to chaos in the cubical lid-driven cavity flow

    Energy Technology Data Exchange (ETDEWEB)

    Loiseau, J-Ch [Department of Mechanics, Royal Institute of Technology (KTH), SE-100 44 Stockholm (Sweden); Robinet, J-Ch [Laboratoire DynFluid, Arts et Métiers ParisTech, F-75013 Paris (France); Leriche, E, E-mail: loiseau@mech.kth.se [Laboratoire de Mécanique de Lille, Université Lille 1, F-59655 Villeneuve d’Ascq (France)

    2016-12-15

    Transition from steady state to intermittent chaos in the cubical lid-driven cavity flow is investigated numerically. Fully three-dimensional stability analyses have revealed that the flow experiences an Andronov–Poincaré–Hopf bifurcation at a critical Reynolds number Re {sub c} = 1914. As for the 2D-periodic lid-driven cavity flows, the unstable mode originates from a centrifugal instability of the primary vortex core. A Reynolds–Orr analysis reveals that the unstable perturbation relies on a combination of the lift-up and anti lift-up mechanisms to extract its energy from the base flow. Once linearly unstable, direct numerical simulations show that the flow is driven toward a primary limit cycle before eventually exhibiting intermittent chaotic dynamics. Though only one eigenpair of the linearized Navier–Stokes operator is unstable, the dynamics during the intermittencies are surprisingly well characterized by one of the stable eigenpairs. (paper)

  12. Modelling of cross-flow membrane contactors : Physical mass transfer processes

    NARCIS (Netherlands)

    Dindore, V. Y.; Brilman, D. W. F.; Versteeg, G. F.

    2005-01-01

    Traditionally, hollow fiber membrane contactors used for gas-liquid contacting were designed in a shell and tube configuration with shell-side fluid flowing parallel to the fiber-side fluid, either in co-current or counter-current pattern. The primary limitations of these so-called 'parallel flow'

  13. Thermal performance modeling of cross-flow heat exchangers

    CERN Document Server

    Cabezas-Gómez, Luben; Saíz-Jabardo, José Maria

    2014-01-01

    This monograph introduces a numerical computational methodology for thermal performance modeling of cross-flow heat exchangers, with applications in chemical, refrigeration and automobile industries. This methodology allows obtaining effectiveness-number of transfer units (e-NTU) data and has been used for simulating several standard and complex flow arrangements configurations of cross-flow heat exchangers. Simulated results have been validated through comparisons with results from available exact and approximate analytical solutions. Very accurate results have been obtained over wide ranges

  14. Phase I Hydrologic Data for the Groundwater Flow and Contaminant Transport Model of Corrective Action Unit 99: Rainier Mesa/Shoshone Mountain, Nevada Test Site, Nye County, Nevada, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Nathan Bryant

    2008-05-01

    This document presents a summary and framework of the available hydrologic data and other information directly relevant to the development of the Rainier Mesa/Shoshone Mountain (RMSM) Corrective Action Unit (CAU) 99 groundwater flow models. Where appropriate, data and information documented elsewhere are briefly summarized with reference to the complete documentation.

  15. Calculation note: project W-320 primary ventilation air flow requirements for mitigation of steady state flammable gas concentrations in the headspaces of tanks 241-C-106 and 241-AY-102

    International Nuclear Information System (INIS)

    Estey, S.D.

    1997-01-01

    This calculation note analyzes headspace concentrations of hydrogen dependent upon assumed ventilation flow rates provided for tanks 241-C-106 and 241-AY-102. The analyses are based on measured or estimated steady state hydrogen release rates. Tank 241-C-106 is analyzed prior to sluicing; tank 241-AY-102 is analyzed both prior to and after completion of sluicing. Specific analyses, using both best estimated and bounding hydrogen generation rates, include the minimum primary ventilation flow rates required in the tanks to ensure that the steady state hydrogen concentration in the respective tank headspace does not exceed 25% and 100% of the LFL. The headspace hydrogen concentration as a function of time as well as the time required to reach 25% and 100% of LFL upon complete loss of active ventilation, starting from the steady state hydrogen concentration based on a 200 CFM minimum flow rate in tank 241-C-106 and a 100 CFM minimum flow rate in tank241-AY-102. The headspace hydrogen concentration as a function of thee following partial loss of active ventilation (i.e., step changes to l60, l20, 80, and 40 CFM ventilation flow rates) in tank 241-C-106, staffing from a 200 CFM flow rate and the corresponding steady state hydrogen concentration based on the 200 CFM flow rate. The headspace hydrogen concentration as a function of the following partial loss of active ventilation i.e., step changes to 80, 60, 40, and 20 CFM ventilation flow rates) in tank 241-AY-102, starting from a 100 CFM flow rate and the corresponding steady state hydrogen concentration based on the 100 CFM flow rate

  16. Separation Dynamics of Controlled Internal Flow in an Adverse Pressure Gradient

    Science.gov (United States)

    Peterson, C. J.; Vukasinovic, B.; Glezer, A.

    2017-11-01

    The effects of fluidic actuation on the dynamic evolution of aggressive internal flow separation is investigated at speeds up to M = 0.4 within a constant-width diffuser branching off of a primary flow duct. It is shown that a spanwise array of fluidic actuators upstream of the separation actively controls the flow constriction (and losses) within the diffuser and consequently the local pressure gradient at its entrance. The effectiveness of the actuation, as may be measured by the increased flow rate that is diverted through the diffuser, scales with its flow rate coefficient. In the presence of actuation (0.7% mass fraction), the mass flow rate in the primary duct increases by 10% while the fraction of the diverted mass flow rate in the diffuser increases by more than 45%. The flow dynamics near separation in the absence and presence of actuation are characterized using high speed particle image velocimetry and analyzed using proper orthogonal and spectral decompositions. In particular, the spectral contents of the incipient boundary layer separation are compared in the absence and presence of actuation with emphasis on the changes in local dynamics near separation as the characteristic cross stream scale of the boundary layer increases with separation delay.

  17. Groundwater Flow Systems at the Nevada Test Site, Nevada: A Synthesis of Potentiometric Contours, Hydrostratigraphy, and Geologic Structures

    Energy Technology Data Exchange (ETDEWEB)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.

    2010-01-25

    Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic

  18. Groundwater Flow Systems at the Nevada Test Site, Nevada: A Synthesis of Potentiometric Contours, Hydrostratigraphy, and Geologic Structures

    Science.gov (United States)

    Fenelon, Joseph M.; Sweetkind, Donald S.; Laczniak, Randell J.

    2010-01-01

    Contaminants introduced into the subsurface of the Nevada Test Site by underground nuclear testing are of concern to the U.S. Department of Energy and regulators responsible for protecting human health and safety. The potential for contaminant movement away from the underground test areas and into the accessible environment is greatest by groundwater transport. The primary hydrologic control on this transport is evaluated and examined through a series of contour maps developed to represent the hydraulic-head distribution within each of the major aquifers underlying the area. Aquifers were identified and their extents delineated by merging and analyzing multiple hydrostratigraphic framework models developed by other investigators from existing geologic information. A map of the hydraulic-head distribution in each major aquifer was developed from a detailed evaluation and assessment of available water-level measurements. Multiple spreadsheets that accompany this report provide pertinent water-level and geologic data by well or drill hole. Aquifers are mapped and discussed in general terms as being one of two types: alluvial-volcanic, or carbonate. Both aquifer types are subdivided and mapped as independent regional and local aquifers, based on the continuity of their component rock. Groundwater-flow directions, approximated from potentiometric contours that were developed from the hydraulic-head distribution, are indicated on the maps and discussed for each of the regional aquifers and for selected local aquifers. Hydraulic heads vary across the study area and are interpreted to range in altitude from greater than 5,000 feet in a regional alluvial-volcanic aquifer beneath a recharge area in the northern part of the study area to less than 2,300 feet in regional alluvial-volcanic and carbonate aquifers in the southwestern part of the study area. Flow directions throughout the study area are dominantly south-southwest with some local deviations. Vertical hydraulic

  19. Survival of Poliovirus in Flowing Turbid Seawater Treated with Ultraviolet Light

    Science.gov (United States)

    Hill, W. F.; Hamblet, F. E.; Akin, E. W.

    1967-01-01

    The effectiveness of a model ultraviolet (UV) radiation unit for treating flowing turbid seawater contaminated with poliovirus was determined. At a turbidity of 70 ppm, the observed survival ratios ranged from 1.9 × 10-3 (99.81% reduction) to 1.5 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 15 liters/min; no virus was recovered at flow rates of 10 and 5 liters/min. At a turbidity of 240 ppm, the observed survival ratios ranged from 3.2 × 10-2 (96.80% reduction) to 2.1 × 10-4 (99.98% reduction) at flow rates ranging from 25 to 5 liters/min. As expected, turbidity had an adverse influence on the effectiveness of UV radiation; however, by adjusting the flow rate of the seawater through the treatment unit, adequate disinfection was shown to be predictable. Images Fig. 1 PMID:4291955

  20. 50 CFR 14.161 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... Wild Mammals and Birds to the United States Specifications for Other Terrestrial Mammals § 14.161... primary enclosure shall provide adequate space for the animal to stand upright in a normal posture with... lie in a full prone position. Specifications for Birds ...

  1. The Coming Primary Care Revolution.

    Science.gov (United States)

    Ellner, Andrew L; Phillips, Russell S

    2017-04-01

    The United States has the most expensive, technologically advanced, and sub-specialized healthcare system in the world, yet it has worse population health status than any other high-income country. Rising healthcare costs, high rates of waste, the continued trend towards chronic non-communicable disease, and the growth of new market entrants that compete with primary care services have set the stage for fundamental change in all of healthcare, driven by a revolution in primary care. We believe that the coming primary care revolution ought to be guided by the following design principles: 1) Payment must adequately support primary care and reward value, including non-visit-based care. 2) Relationships will serve as the bedrock of value in primary care, and will increasingly be fostered by teams, improved clinical operations, and technology, with patients and non-physicians assuming an ever-increasing role in most aspects of healthcare. 3) Generalist physicians will increasingly focus on high-acuity and high-complexity presentations, and primary care teams will increasingly manage conditions that specialists managed in the past. 4) Primary care will refocus on whole-person care, and address health behaviors as well as vision, hearing, dental, and social services. Design based on these principles should lead to higher-value healthcare, but will require new approaches to workforce training.

  2. Flow area optimization in point to area or area to point flows

    International Nuclear Information System (INIS)

    Ghodoossi, Lotfollah; Egrican, Niluefer

    2003-01-01

    This paper deals with the constructal theory of generation of shape and structure in flow systems connecting one point to a finite size area. The flow direction may be either from the point to the area or the area to the point. The formulation of the problem remains the same if the flow direction is reversed. Two models are used in optimization of the point to area or area to point flow problem: cost minimization and revenue maximization. The cost minimization model enables one to predict the shape of the optimized flow areas, but the geometric sizes of the flow areas are not predictable. That is, as an example, if the area of flow is a rectangle with a fixed area size, optimization of the point to area or area to point flow problem by using the cost minimization model will only predict the height/length ratio of the rectangle not the height and length itself. By using the revenue maximization model in optimization of the flow problems, all optimized geometric aspects of the interested flow areas will be derived as well. The aim of this paper is to optimize the point to area or area to point flow problems in various elemental flow area shapes and various structures of the flow system (various combinations of elemental flow areas) by using the revenue maximization model. The elemental flow area shapes used in this paper are either rectangular or triangular. The forms of the flow area structure, made up of an assembly of optimized elemental flow areas to obtain bigger flow areas, are rectangle-in-rectangle, rectangle-in-triangle, triangle-in-triangle and triangle-in-rectangle. The global maximum revenue, revenue collected per unit flow area and the shape and sizes of each flow area structure have been derived in optimized conditions. The results for each flow area structure have been compared with the results of the other structures to determine the structure that provides better performance. The conclusion is that the rectangle-in-triangle flow area structure

  3. A Comparison of Flow-Through Versus Non-Flow-Through Proton Exchange Membrane Fuel Cell Systems for NASA's Exploration Missions

    Science.gov (United States)

    Hoberecht, Mark A.

    2010-01-01

    As part of the Exploration Technology Development Program (ETDP) under the auspices of the Exploration Systems Mission Directorate (ESMD), NASA is developing both primary fuel cell power systems and regenerative fuel cell (RFC) energy storage systems within the fuel cell portion of the Energy Storage Project. This effort is being led by the NASA Glenn Research Center (GRC) in partnership with the NASA Johnson Space Center (JSC), Jet Propulsion Laboratory (JPL), NASA Kennedy Space Center (KSC), and industrial partners. The development goals are to improve fuel cell and electrolysis stack electrical performance, reduce system mass, volume, and parasitic power requirements, and increase system life and reliability. A major focus of this effort has been the parallel development of both flow-through and non-flow-through proton exchange membrane (PEM) primary fuel cell power systems. The plan has been, at the appropriate time, to select a single primary fuel cell technology for eventual flight hardware development. Ideally, that appropriate time would occur after both technologies have achieved a technology readiness level (TRL) of six, which represents an engineering model fidelity PEM fuel cell system being successfully tested in a relevant environment. Budget constraints in fiscal year 2009 and beyond have prevented NASA from continuing to pursue the parallel development of both primary fuel cell options. Because very limited data exists for either system, a toplevel, qualitative assessment based on engineering judgement was performed expeditiously to provide guidance for a selection. At that time, the non-flow-through technology was selected for continued development because of potentially major advantages in terms of weight, volume, parasitic power, reliability, and life. This author believes that the advantages are significant enough, and the potential benefits great enough, to offset the higher state of technology readiness of flow-through technology. This paper

  4. Inhibitory Effects of Far-Infrared Ray-Emitting Belts on Primary Dysmenorrhea

    Directory of Open Access Journals (Sweden)

    Ben-Yi Liau

    2012-01-01

    Full Text Available This study investigated the therapeutic effect of the far-infrared ray-emitting belt (FIRB in the management of primary dysmenorrhea in female patients. Forty adolescent females with primary dysmenorrhea were enrolled in the study. Quantitative measurements were taken during the menstruation. Several parameters were measured and compared, including temperature, abdominal blood flow, heart rate variability, and pain assessment. Statistical analysis shows that treatment with FIRB had significant efficiency in increasing regional surface temperature and abdominal blood flow, widening standard deviation of normal-to-normal RR intervals, and reducing VRS and NRS pain scores. The application of an FIRB appears to alleviate dysmenorrhea.

  5. Vapor generating unit blowdown arrangement

    International Nuclear Information System (INIS)

    McDonald, B.N.

    1978-01-01

    A vapor generating unit having a U-shaped tube bundle is provided with an orificed downcomer shroud and a fluid flow distribution plate between the lower hot and cold leg regions to promote fluid entrained sediment deposition in proximity to an apertured blowdown pipe

  6. Well Installation Report for Corrective Action Unit 443, Central Nevada Test Area, Nye County, Nevada

    International Nuclear Information System (INIS)

    Tim Echelard

    2006-01-01

    A Corrective Action Investigation (CAI) was performed in several stages from 1999 to 2003, as set forth in the ''Corrective Action Investigation Plan for the Central Nevada Test Area Subsurface Sites, Corrective Action Unit 443'' (DOE/NV, 1999). Groundwater modeling was the primary activity of the CAI. Three phases of modeling were conducted for the Faultless underground nuclear test. The first phase involved the gathering and interpretation of geologic and hydrogeologic data, and inputting the data into a three-dimensional numerical model to depict groundwater flow. The output from the groundwater flow model was used in a transport model to simulate the migration of a radionuclide release (Pohlmann et al., 2000). The second phase of modeling (known as a Data Decision Analysis [DDA]) occurred after NDEP reviewed the first model. This phase was designed to respond to concerns regarding model uncertainty (Pohll and Mihevc, 2000). The third phase of modeling updated the original flow and transport model to incorporate the uncertainty identified in the DDA, and focused the model domain on the region of interest to the transport predictions. This third phase culminated in the calculation of contaminant boundaries for the site (Pohll et al., 2003). Corrective action alternatives were evaluated and an alternative was submitted in the ''Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area-Subsurface'' (NNSA/NSO, 2004). Based on the results of this evaluation, the preferred alternative for CAU 443 is Proof-of-Concept and Monitoring with Institutional Controls. This alternative was judged to meet all requirements for the technical components evaluated and will control inadvertent exposure to contaminated groundwater at CAU 443

  7. Local Nusselt number enhancement during gas-liquid Taylor bubble flow in a square mini-channel: An experimental study

    International Nuclear Information System (INIS)

    Majumder, Abhik; Mehta, Balkrishna; Khandekar, Sameer

    2013-01-01

    Taylor bubble flow takes place when two immiscible fluids (liquid-liquid or gas-liquid) flow inside a tube of capillary dimensions within specific range of volume flow ratios. In the slug flows where gas and liquid are two different phases, liquid slugs are separated by elongated Taylor bubbles. This singular flow pattern is observed in many engineering mini-/micro-scale devices like pulsating heat pipes, gas-liquid-solid monolithic reactors, micro-two-phase heat exchangers, digital micro-fluidics, micro-scale mass transfer process, fuel cells, etc. The unique and complex flow characteristics require understanding on local, as well as global, spatio-temporal scales. In the present work, the axial stream-wise profile of the fluid and wall temperature for air-water (i) isolated single Taylor bubble and, (ii) a train of Taylor bubbles, in a horizontal square channel of size 3.3 mm x 3.3 mm x 350 mm, heated from the bottom (heated length = 175 mm), with the other three sides kept insulated, are reported at different gas volume flow ratios. The primary aim is to study the enhancement of heat transfer due to the Taylor bubble train flow, in comparison with thermally developing single-phase flows. Intrusion of a bubble in the liquid flow drastically changes the local temperature profiles. The axial distribution of time-averaged local Nusselt number (Nu z ) shows that Taylor bubble train regime increases the transport of heat up to 1.2-1.6 times more as compared with laminar single-phase liquid flow. In addition, for a given liquid flow Reynolds number, the heat transfer enhancement is a function of the geometrical parameters of the unit cell, i.e., the length of adjacent gas bubble and water plug. (authors)

  8. Plate heat exchanger - inertia flywheel performance in loss of flow transient

    International Nuclear Information System (INIS)

    Abou-El-Maaty, Talal; Abd-El-Hady, Amr

    2009-01-01

    One of the most versatile types of heat exchangers used is the plate heat exchanger. It has principal advantages over other heat exchangers in that plates can be added and/or removed easily in order to change the area available for heat transfer and therefore its overall performance. The cooling systems of Egypt's second research reactor (ETRR 2) use this type of heat exchanger for cooling purposes in its primary core cooling and pool cooling systems. In addition to the change in the number of heat exchanger cooling channels, the effect of changing the amount of mass flow rate on the heat exchanger performance is an important issues in this study. The inertia flywheel mounted on the primary core cooling system pump with the plate heat exchanger plays an important role in the case of loss of flow transients. The PARET code is used to simulate the effect of loss of flow transients on the reactor core. Hence, the core outlet temperature with the pump-flywheel flow coast down is fed into the plate heat exchanger model developed to estimate the total energy transferred to the cooling tower, the primary side heat exchanger temperature variation, the transmitted heat exchanger power, and the heat exchanger effectiveness. In addition, the pressure drop in both, the primary side and secondary side of the plate heat exchanger is calculated in all simulated transients because their values have limits beyond which the heat exchanger is useless. (orig.)

  9. Control system for a nuclear power producing unit

    International Nuclear Information System (INIS)

    Durrant, O.W.

    1978-01-01

    The invention provides in a control system for a nuclear power producing unit comprising a pressurized water reactor, a once-through steam generator provided with feedwater supply means, a turbine-generator supplied with steam from the steam generator and means maintaining a flow of pressurized water through the reactor and steam generator. The combination comprising; means generating a feed forward control signal proportional to the desired power output of the power producing unit, a second means for adjusting the reactor heat release, a third means for adjusting the rate of flow of feedwater to the steam generator, the second and third means solely responsive to and operated in parallel from the feed forward control signal whereby the reactor heat release and the rate of flow of feedwater to the steam generator are each maintained in a discrete functional relationship to the feed forward control signal

  10. The Nature of Primary Students' Conversation in Technology Education

    Science.gov (United States)

    Fox-Turnbull, Wendy H.

    2016-01-01

    Classroom conversations are core to establishing successful learning for students. This research explores the nature of conversation in technology education in the primary classroom and the implications for teaching and learning. Over a year, two units of work in technology were taught in two primary classrooms. Most data was gathered in Round 2…

  11. Predictive Control of Demand Side Units Participating in the Primary Frequency Reserve Market

    DEFF Research Database (Denmark)

    Biegel, Benjamin; Stoustrup, Jakob; Andersen, Palle

    2013-01-01

    We consider an aggregator controlling a mixed portfolio of conventional power generators and demand side units. The generators are controllable within certain power and ramp limitations while the demand side units are characterized by flexible consumptions and therefore can be treated as energy...

  12. 50 CFR 14.142 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Primary enclosures. 14.142 Section 14.142 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING... outside the enclosure. Specifications for Sloths, Bats, and Flying Lemurs (Cynocephalidae) ...

  13. Generalized Couette Poiseuille flow with boundary mass transfer

    Science.gov (United States)

    Marques, F.; Sanchez, J.; Weidman, P. D.

    1998-11-01

    A generalized similarity formulation extending the work of Terrill (1967) for Couette Poiseuille flow in the annulus between concentric cylinders of infinite extent is given. Boundary conditions compatible with the formulation allow a study of the effects of inner and outer cylinder transpiration, rotation, translation, stretching and twisting, in addition to that of an externally imposed constant axial pressure gradient. The problem is governed by [eta], the ratio of inner to outer radii, a Poiseuille number, and nine Reynolds numbers. Single-cylinder and planar problems can be recovered in the limits [eta][rightward arrow]0 and [eta][rightward arrow]1, respectively. Two coupled primary nonlinear equations govern the meridional motion generated by uniform mass flux through the porous walls and the azimuthal motion generated by torsional movement of the cylinders; subsidiary equations linearly slaved to the primary flow govern the effects of cylinder translation, cylinder rotation, and an external pressure gradient. Steady solutions of the primary equations for uniform source/sink flow of strength F through the inner cylinder are reported for 0[less-than-or-eq, slant][eta][less-than-or-eq, slant]1. Asymptotic results corroborating the numerical solutions are found in different limiting cases. For F0 is more complex in that unique solutions are found at low Reynolds numbers, a region of triple solutions exists at moderate Reynolds numbers, and a two-cell solution prevails at large Reynolds numbers. The subsidiary linear equations are solved at [eta]=0.5 to exhibit the effects of cylinder translation, rotation, and an axial pressure gradient on the source/sink flows.

  14. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Science.gov (United States)

    2010-10-01

    ... or secondary Division 2.1 (flammable gas) hazard. For single unit tank cars, interior pipes of... lading exceeding 1.52 mm (0.060 inch) diameter must be equipped with excess flow valves. For single unit... inches) glass fiber placed over 5.08 cm (2 inches) of ceramic fiber. Tank cars must have excess flow...

  15. A Database and Meta-Analysis of Ecological Responses to Flow in the South Atlantic Region

    Energy Technology Data Exchange (ETDEWEB)

    McManamay, Ryan A [ORNL; Orth, Dr. Donald J [Virginia Polytechnic Institute and State University (Virginia Tech); Davis, Dr, Mary [Southeastern Aquatic Resources Partnership; Kauffman, John [John Kauffman LLC.

    2013-01-01

    Generalized and quantitative relationships between flow and ecology are pivotal to developing environmental flow standards based on socially acceptable ecological conditions. Informing management at regional scales requires compiling sufficient hydrologic and ecological sources of information, identifying information gaps, and creating a framework for hypothesis development and testing. We compiled studies of empirical and theoretical relationships between flow and ecology in the South Atlantic region (SAR) of the United States to evaluate their utility for the development of environmental flow standards. Using database searches, internet searches, and agency contacts, we gathered 186 sources of information that provided a qualitative or quantitative relationship between flow and ecology within states encompassing the SAR. A total of 109 of the 186 sources had sufficient information to support quantitative analyses. Ecological responses to natural changes in flow magnitude, frequency, and duration were highly variable regardless of the direction and magnitude of changes in flow. In contrast, the majority of ecological responses to anthropogenic-induced flow alterations were negative. Fish consistently showed negative responses to anthropogenic flow alterations whereas other ecological groups showed somewhat variable responses (e.g. macroinvertebrates and riparian vegetation) and even positive responses (e.g. algae). Fish and organic matter had sufficient sample sizes to stratify natural flow-ecology relationships by specific flow categories (e.g. high flow, baseflows) or by region (e.g. coastal plain, uplands). After stratifying relationships, we found that significant correlations existed between changes in natural flow and ecological responses. In addition, a regression tree explained 57% of the variation in fish responses to anthropogenic and natural changes in flow. Because of some ambiguity in interpreting the directionality in ecological responses, we

  16. Wet and Dry Atmospheric Mercury Deposition Accumulates in Watersheds of the Northeastern United States

    Science.gov (United States)

    Boyer, E. W.; Grant, C.; Grimm, J.; Drohan, P. J.; Bennett, J.; Lawler, D.

    2013-12-01

    Mercury emissions to the atmosphere from coal-fired power plants and other sources such as waste incineration can be deposited to landscapes in precipitation and in dry fallout. Some mercury reaches watersheds and streams, where it can accumulate in sediments and biota. Human exposure to mercury occurs primarily through fish consumption, and currently mercury fish eating advisories are in place for many of the streams and lakes in the state. Here, we explored mercury in air, soils, water, and biota. To quantify atmospheric mercury deposition, we measured both wet and dry mercury deposition at over 10 locations in Pennsylvania, from which we present variation in mercury deposition and initial assessments of factors affecting the patterns. Further, we simulated mercury deposition at unmonitored locations in Pennsylvania and the northeastern United States over space and time with a high-resolution modeling technique that reflects storm tracks and air flow patterns. To consider mercury accumulation in watersheds, we collected data on soil mercury concentrations in a set of soil samples, and collected baseline data on mercury in streams draining 35 forested watersheds across Pennsylvania, spanning gradients of atmospheric deposition, climate and geology. Mercury concentrations were measured in stream water under base-flow conditions, in streambed sediments, aquatic mosses, and in fish tissues from brook trout. Results indicate that wet and dry atmospheric deposition is a primary source of mercury that is accumulating in watersheds of Pennsylvania and the northeastern United States.

  17. MAXIMUM PRINCIPLE FOR SUBSONIC FLOW WITH VARIABLE ENTROPY

    Directory of Open Access Journals (Sweden)

    B. Sizykh Grigory

    2017-01-01

    Full Text Available Maximum principle for subsonic flow is fair for stationary irrotational subsonic gas flows. According to this prin- ciple, if the value of the velocity is not constant everywhere, then its maximum is achieved on the boundary and only on the boundary of the considered domain. This property is used when designing form of an aircraft with a maximum critical val- ue of the Mach number: it is believed that if the local Mach number is less than unit in the incoming flow and on the body surface, then the Mach number is less then unit in all points of flow. The known proof of maximum principle for subsonic flow is based on the assumption that in the whole considered area of the flow the pressure is a function of density. For the ideal and perfect gas (the role of diffusion is negligible, and the Mendeleev-Clapeyron law is fulfilled, the pressure is a function of density if entropy is constant in the entire considered area of the flow. Shows an example of a stationary sub- sonic irrotational flow, in which the entropy has different values on different stream lines, and the pressure is not a function of density. The application of the maximum principle for subsonic flow with respect to such a flow would be unreasonable. This example shows the relevance of the question about the place of the points of maximum value of the velocity, if the entropy is not a constant. To clarify the regularities of the location of these points, was performed the analysis of the com- plete Euler equations (without any simplifying assumptions in 3-D case. The new proof of the maximum principle for sub- sonic flow was proposed. This proof does not rely on the assumption that the pressure is a function of density. Thus, it is shown that the maximum principle for subsonic flow is true for stationary subsonic irrotational flows of ideal perfect gas with variable entropy.

  18. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  19. Three dimensional calculations of the primary coolant flow in a 900 MW PWR vessel. Steady state and transients computations

    International Nuclear Information System (INIS)

    Martin, A.; Alvarez, D.; Cases, F.

    1996-03-01

    The paper explains the chronological account and the first results obtained in the R and D program on the mixing in the 900 MW PWR vessels. After the presentation of the plant type simulated, we define the numerical tool, the (Finite Element Modelling) FEM N3S code. Two results are presented with a comparison with the experiment results issued of the BORA BORA mock up. The first case is dealing with the isothermal steady state mixing in the vessel with the three loops mass flow rate balanced. This case identified as a validation of our numerical tool shows a good agreement. The second case is dealing with the transient mixing of a clear plug in the vessel when one primary pump starts-up. We compare the numerical and experiment results giving the mean boron concentration at the core inlet for several clear water plugs. The results show again a good agreement. (authors). 12 refs., 10 figs., 1 tab

  20. Assessing the impact of primary measures for NOx reduction on the thermal power plant steam boiler

    International Nuclear Information System (INIS)

    Stupar, Goran; Tucaković, Dragan; Živanović, Titoslav; Belošević, Srdjan

    2015-01-01

    The European normatives prescribe content of 200 mg/Nm 3 NO x for pulverized coal combusting power plants. In order to reduce content of NO x in Serbian thermal power plant (TPP) 'Kostolac B' it's necessary to implement particular measures until 2016. The mathematical model of lignite combustion in the steam boiler furnace is defined and applied to analyze the possibility of implementing certain primary measures for reducing nitrogen oxides and their effects on the steam boiler operation. This model includes processes in the coal-fired furnace and defines radiating reactive two-phase turbulent flow. The model of turbulent flow also contains sub-model of fuel and thermal NO x formation and destruction. This complex mathematical model is related to thermal and aerodynamic calculations of the steam boiler within a unified calculation system in order to analyze the steam boiler overall work. This system provides calculations with a number of influential parameters. The steam boiler calculations for unit 1 (350 MWe) of TPP 'Kostolac B' are implemented for existing and modified combustion system in order to achieve effective, reliable and ecological facility work. The paper presents the influence analysis of large number of parameters on the steam boiler operation with an accepted concept of primary measures. Presented system of calculations is verified against measurements in TPP 'Kostolac B'. - Highlights: • Modern steam boilers need to operate according to ecological standards. • Possibility of applying some of the primary measures of NO x reduction. • Conventional calculations have no possibility to estimate sub-stoichiometric combustion. • Develop a new method of connecting the calculations. • Analysis shows the most favorable operation boiler regime (efficiency and ecology)

  1. The Dynamics of Controlled Flow Separation within a Diverter Duct Diffuser

    Science.gov (United States)

    Peterson, C. J.; Vukasinovic, B.; Glezer, A.

    2016-11-01

    The evolution and receptivity to fluidic actuation of the flow separation within a rectangular, constant-width, diffuser that is branched off of a primary channel is investigated experimentally at speeds up to M = 0.4. The coupling between the diffuser's adverse pressure gradient and the internal separation that constricts nearly half of the flow passage through the duct is controlled using a spanwise array of fluidic actuators on the surface upstream of the diffuser's inlet plane. The dynamics of the separating surface vorticity layer in the absence and presence of actuation are investigated using high-speed particle image velocimetry combined with surface pressure measurements and total pressure distributions at the primary channel's exit plane. It is shown that the actuation significantly alters the incipient dynamics of the separating vorticity layer as the characteristic cross stream scales of the boundary layer upstream of separation and of the ensuing vorticity concentrations within the separated flow increase progressively with actuation level. It is argued that the dissipative (high frequency) actuation alters the balance between large- and small-scale motions near separation by intensifying the large-scale motions and limiting the small-scale dynamics. Controlling separation within the diffuser duct also has a profound effect on the global flow. In the presence of actuation, the mass flow rate in the primary duct increases 10% while the fraction of the diverted mass flow rate in the diffuser increases by more than 45% at 0.7% actuation mass fraction. Supported by the Boeing Company.

  2. Modified laminar flow biological safety cabinet.

    Science.gov (United States)

    McGarrity, G J; Coriell, L L

    1974-10-01

    Tests are reported on a modified laminar flow biological safety cabinet in which the return air plenum that conducts air from the work area to the high efficiency particulate air filters is under negative pressure. Freon gas released inside the cabinet could not be detected outside by a freon gas detection method capable of detecting 10(-6) cc/s. When T3 bacteriophage was aerosolized 5 cm outside the front opening in 11 tests, no phage could be detected inside the cabinet with the motor-filter unit in operation. An average of 2.8 x 10(5) plaque-forming units (PFU)/ft(3) (ca. 0.028 m(3)) were detected with the motor-filter unit not in operation, a penetration of 0.0%. Aerosolization 5 cm inside the cabinet yielded an average of 10 PFU/ft(3) outside the cabinet with the motor-filter unit in operation and an average of 4.1 x 10(5) PFU/ft(3) with the motor-filter unit not in operation, a penetration of 0.002%. These values are the same order of effectiveness as the positive-pressure laminar flow biological safety cabinets previously tested. The advantages of the negative-pressure return plenum design include: (i) assurance that if cracks or leaks develop in the plenum it will not lead to discharge of contaminated air into the laboratory; and (ii) the price is lower due to reduced manufacturing costs.

  3. Investigation of secondary flows in turbulent pipe flows with three-dimensional sinusoidal walls

    Science.gov (United States)

    Chan, Leon; MacDonald, Michael; Chung, Daniel; Hutchins, Nicholas; Ooi, Andrew

    2017-11-01

    The occurrence of secondary flows is systematically investigated via Direct Numerical Simulations (DNS) of turbulent flow in a rough wall pipe at friction Reynolds numbers of 540. In this study, the peak-to-trough height of the roughness elements, which consist of three-dimensional sinusoidal roughness, is fixed at 120 viscous units while the wavelength of the roughness elements is varied. The solidity or effective slope (ES) of the roughness ranges from the sparse regime (ES = 0.18) to the closely packed roughness/dense regime (ES = 0.72). The time-independent dispersive stresses, which arise due to the stationary features of the flow, are analysed and are found to increase with increasing roughness wavelength. These dispersive stresses are related to the occurrence of secondary flows and are maximum within the roughness canopy. Above the crest of the roughness elements, the dispersive stresses reduce to zero at wall-normal heights greater than half of the roughness wavelength. This study has found that the size and wall-normal extent of the secondary flows scales with the roughness wavelength and can reach wall-normal heights of almost half of the pipe radius.

  4. Defibrillator implantations for primary prevention in the United States: Inappropriate care or inadequate documentation: Insights from the National Cardiovascular Data ICD Registry.

    Science.gov (United States)

    Kaiser, Daniel W; Tsai, Vivian; Heidenreich, Paul A; Goldstein, Mary K; Wang, Yongfei; Curtis, Jeptha; Turakhia, Mintu P

    2015-10-01

    Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials that have demonstrated the efficacy of primary prevention ICDs. Using data from the National Cardiovascular Data Registry's ICD Registry, we identified patients who received ICDs for primary prevention from January 2006 to December 2008. We determined whether patients met the inclusion criteria of at least 1 of the 4 ICD primary prevention trials: Multicenter Automatic Defibrillator Implantation Trial (MADIT), MADIT-II, Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and the Multicenter Unsustained Tachycardia Trial (MUSTT). Among 150,264 patients, 86% met criteria for an ICD implantation based on trial data. The proportion of patients who did not meet trial-based criteria increased as age decreased. In multivariate analysis, the significant predictors for not meeting trial criteria included prior cardiac transplantation (odds ratio [OR] 2.1), pediatric electrophysiology operator (OR 2.0), and high-grade atrioventricular conduction disease (OR 1.4). Among National Cardiovascular Data Registry registrants receiving first-time ICDs for primary prevention, the majority met trial-based criteria. Multivariate analyses suggested that many patients who did not meet the trial-based criteria may have had clinical circumstances that warranted ICD implantation. These findings caution against the use of trial-based indications to determine site quality metrics that could penalize sites that care for younger patients. The planned incorporation of appropriate use criteria into the ICD registry may better characterize patient- and site-level quality and performance. Published by Elsevier Inc.

  5. Sensitivity Analysis for Steady State Groundwater Flow Using Adjoint Operators

    Science.gov (United States)

    Sykes, J. F.; Wilson, J. L.; Andrews, R. W.

    1985-03-01

    Adjoint sensitivity theory is currently being considered as a potential method for calculating the sensitivity of nuclear waste repository performance measures to the parameters of the system. For groundwater flow systems, performance measures of interest include piezometric heads in the vicinity of a waste site, velocities or travel time in aquifers, and mass discharge to biosphere points. The parameters include recharge-discharge rates, prescribed boundary heads or fluxes, formation thicknesses, and hydraulic conductivities. The derivative of a performance measure with respect to the system parameters is usually taken as a measure of sensitivity. To calculate sensitivities, adjoint sensitivity equations are formulated from the equations describing the primary problem. The solution of the primary problem and the adjoint sensitivity problem enables the determination of all of the required derivatives and hence related sensitivity coefficients. In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Alternatively, local velocity related performance measures are more sensitive to hydraulic conductivities.

  6. Specialists meeting on LMFBR flow induced vibrations. Summary report

    International Nuclear Information System (INIS)

    1977-12-01

    A Specialists' Meeting on LMFBR Flow-Induced Vibrations was held at ANL in the United States which was sponsored by the International Atomic Energy Agency (IAEA) on the recommendations of the International Working Group on Fast Reactors (IWGFR). It was attended by participants from France, the Federal Republic of Germany, Italy, Japan, Netherlands, the United Kingdom, the Union of Soviet Socialist Republics, the United States and the IAEA. The purpose of the meeting was to provide, for the first time, a common forum for the exchange of information on flow-induced vibration programs of the member countries. As this was a first meeting, information was sought in the broad areas of: 1. Design Criteria and Problem Areas in LMFBR Design; 2. Current Design Procedures; and 3. Ongoing Research. A session was devoted to each of the above topics wherein papers were presented and discussed followed by open discussions on the session topic. The objective of the open discussions was to identify, from a review of specific reactor designs, (a) flow induced vibration problem areas (expected and observed) and their potential for occurrence; (b) failure modes and associated design criteria; (c) specific components that are susceptible to flow induced vibration; and (d) probable excitation mechanisms. It was aimed to assess the current state-of-the-art in designing to avoid flow induced vibration with consideration of licensing requirements; to evaluate existing methods of analysis, testing, and surveillance, along with their limitations and to identify areas requiring research and review ongoing research programmes relative to these research needs

  7. Specialists meeting on LMFBR flow induced vibrations. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-12-01

    A Specialists' Meeting on LMFBR Flow-Induced Vibrations was held at ANL in the United States which was sponsored by the International Atomic Energy Agency (IAEA) on the recommendations of the International Working Group on Fast Reactors (IWGFR). It was attended by participants from France, the Federal Republic of Germany, Italy, Japan, Netherlands, the United Kingdom, the Union of Soviet Socialist Republics, the United States and the IAEA. The purpose of the meeting was to provide, for the first time, a common forum for the exchange of information on flow-induced vibration programs of the member countries. As this was a first meeting, information was sought in the broad areas of: 1. Design Criteria and Problem Areas in LMFBR Design; 2. Current Design Procedures; and 3. Ongoing Research. A session was devoted to each of the above topics wherein papers were presented and discussed followed by open discussions on the session topic. The objective of the open discussions was to identify, from a review of specific reactor designs, (a) flow induced vibration problem areas (expected and observed) and their potential for occurrence; (b) failure modes and associated design criteria; (c) specific components that are susceptible to flow induced vibration; and (d) probable excitation mechanisms. It was aimed to assess the current state-of-the-art in designing to avoid flow induced vibration with consideration of licensing requirements; to evaluate existing methods of analysis, testing, and surveillance, along with their limitations and to identify areas requiring research and review ongoing research programmes relative to these research needs.

  8. Fast Flux Test Facility primary sodium valves

    International Nuclear Information System (INIS)

    Rabe, G.B.; Ezra, B.C.

    1977-01-01

    The design and development of the valves used in the primary sodium coolant loop of the Fast Flux Test Facility is described. One tilting-disk check valve is used in the cold leg of the coolant loop. It is designed to limit flow reversal in the loop while maintaining a low pressure drop during forward flow. Two isolation valves are used in each coolant loop--one in the cold leg and one in the hot leg. They are of the motor-operated swinging-gate type. The design, analysis, and testing programs undertaken to develop and qualify these valves are described

  9. Experimental and numerical study of hydrodynamics of flow-accelerated corrosion in CANDU primary coolant

    Energy Technology Data Exchange (ETDEWEB)

    Supa-Amornkul, S

    2006-07-01

    In CANDU-6 reactors, the pressurised high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310{sup o}C with up to 0.30 steam voidage, turns through 90{sup o} as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations reported excessive corrosion of their outlet feeder pipes, especially over the first metre, which consists of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow-accelerated corrosion (FAC). Local shear stress, which is believed to be one of the important factors contributing to FAC, was approximated in the studies with standard empirical correlations. In order to understand the hydrodynamics of the coolant in the outlet feeders, flow-visualisation studies were done at AECL and UNB. At AECL, the observations were confined to a transparent simulation of an outlet feeder bend but at UNB a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting was fabricated. The feeder consisted of a 54 mm (inside diameter) acrylic pipe with a 73{sup o} bend, connected to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outside diameter, and an outer pipe, 150 mm inside diameter, both 1.907 m long. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 0.019 m{sup 3}/s and the volume fraction of air varied from 0.05 to 0.56. In characterizing the flow in the UNB study, particular attention was paid to the patterns at the inside of the bend, where a CFD (computational fluid dynamics) code

  10. Experimental and numerical study of hydrodynamics of flow-accelerated corrosion in CANDU primary coolant

    International Nuclear Information System (INIS)

    Supa-Amornkul, S.

    2006-01-01

    In CANDU-6 reactors, the pressurised high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310 o C with up to 0.30 steam voidage, turns through 90 o as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations reported excessive corrosion of their outlet feeder pipes, especially over the first metre, which consists of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow-accelerated corrosion (FAC). Local shear stress, which is believed to be one of the important factors contributing to FAC, was approximated in the studies with standard empirical correlations. In order to understand the hydrodynamics of the coolant in the outlet feeders, flow-visualisation studies were done at AECL and UNB. At AECL, the observations were confined to a transparent simulation of an outlet feeder bend but at UNB a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting was fabricated. The feeder consisted of a 54 mm (inside diameter) acrylic pipe with a 73 o bend, connected to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outside diameter, and an outer pipe, 150 mm inside diameter, both 1.907 m long. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 0.019 m 3 /s and the volume fraction of air varied from 0.05 to 0.56. In characterizing the flow in the UNB study, particular attention was paid to the patterns at the inside of the bend, where a CFD (computational fluid dynamics) code - Fluent 6.1- had

  11. Innovations in Primary Health Care: the use of communications technology and information tools to support local management.

    Science.gov (United States)

    Pinto, Luiz Felipe; Rocha, Cristianne Maria Famer

    2016-05-01

    Social media has been used in different contexts as a way to streamline the flow of data and information for decision making. This has contributed to the issue of knowledge production in networks and the expansion of communication channels so that there is greater access to health services. This article describes the results of research done on 16 Information Technology and Communications Observatories in Health Care - OTICS Network in Rio - covering the Municipal Health Secretariat in Rio de Janeiro which supported the integration of primary health care and promoted the monitoring of health. It is a descriptive case study. The results relate to the support given to employees in training covering the dissemination of information, communication, training and information management in primary health care. This innovative means of communication in public health, with very little cost to the Unified Health System (SUS), allowed for a weekly registering of work processes for teams that worked in 193 primary health care units (APS) using blogs, whose total accesses reached the seven million mark in mid-2015. In the future there is a possibility that distance learning tools could be used to assist in training processes and in the continuing education of professionals in family health teams.

  12. Construction and calibration of a groundwater-flow model to assess groundwater availability in the uppermost principal aquifer systems of the Williston Basin, United States and Canada

    Science.gov (United States)

    Davis, Kyle W.; Long, Andrew J.

    2018-05-31

    The U.S. Geological Survey developed a groundwater-flow model for the uppermost principal aquifer systems in the Williston Basin in parts of Montana, North Dakota, and South Dakota in the United States and parts of Manitoba and Saskatchewan in Canada as part of a detailed assessment of the groundwater availability in the area. The assessment was done because of the potential for increased demands and stresses on groundwater associated with large-scale energy development in the area. As part of this assessment, a three-dimensional groundwater-flow model was developed as a tool that can be used to simulate how the groundwater-flow system responds to changes in hydrologic stresses at a regional scale.The three-dimensional groundwater-flow model was developed using the U.S. Geological Survey’s numerical finite-difference groundwater model with the Newton-Rhapson solver, MODFLOW–NWT, to represent the glacial, lower Tertiary, and Upper Cretaceous aquifer systems for steady-state (mean) hydrological conditions for 1981‒2005 and for transient (temporally varying) conditions using a combination of a steady-state period for pre-1960 and transient periods for 1961‒2005. The numerical model framework was constructed based on existing and interpreted hydrogeologic and geospatial data and consisted of eight layers. Two layers were used to represent the glacial aquifer system in the model; layer 1 represented the upper one-half and layer 2 represented the lower one-half of the glacial aquifer system. Three layers were used to represent the lower Tertiary aquifer system in the model; layer 3 represented the upper Fort Union aquifer, layer 4 represented the middle Fort Union hydrogeologic unit, and layer 5 represented the lower Fort Union aquifer. Three layers were used to represent the Upper Cretaceous aquifer system in the model; layer 6 represented the upper Hell Creek hydrogeologic unit, layer 7 represented the lower Hell Creek aquifer, and layer 8 represented the Fox

  13. Indoor unit for electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  14. Adapting high-level language programs for parallel processing using data flow

    Science.gov (United States)

    Standley, Hilda M.

    1988-01-01

    EASY-FLOW, a very high-level data flow language, is introduced for the purpose of adapting programs written in a conventional high-level language to a parallel environment. The level of parallelism provided is of the large-grained variety in which parallel activities take place between subprograms or processes. A program written in EASY-FLOW is a set of subprogram calls as units, structured by iteration, branching, and distribution constructs. A data flow graph may be deduced from an EASY-FLOW program.

  15. Aging mourning doves by outer primary wear

    Science.gov (United States)

    Wight, H.M.; Blankenship, L.H.; Tomlinson, R.E.

    1967-01-01

    Many immature mourning doves (Zenaidura macroura) cannot be aged by the conventional white-tipped primary covert method if molt has proceeded beyond the 7th primary. A new method of aging doves in this group is based on the presence (immature) or absence (adult) of a buff-colored fringe on the tips of the 9th and 10th primaries. Experienced biologists were nearly 100 percent accurate in aging wings of 100 known-age doves from eastern and midwestern states. The technique is not as reliable for doves from southwestern United States because of added feather wear, apparently from harsh vegetative and soil conditions.

  16. [Research progress in post-fire debris flow].

    Science.gov (United States)

    Di, Xue-ying; Tao, Yu-zhu

    2013-08-01

    The occurrence of the secondary disasters of forest fire has significant impacts on the environment quality and human health and safety. Post-fire debris flow is one of the most hazardous secondary disasters of forest fire. To understand the occurrence conditions of post-fire debris flow and to master its occurrence situation are the critical elements in post-fire hazard assessment. From the viewpoints of vegetation, precipitation threshold and debris flow material sources, this paper elaborated the impacts of forest fire on the debris flow, analyzed the geologic and geomorphic conditions, precipitation and slope condition that caused the post-fire debris flow as well as the primary mechanisms of debris-flow initiation caused by shallow landslide or surface runoff, and reviewed the research progress in the prediction and forecast of post-fire debris flow and the related control measures. In the future research, four aspects to be focused on were proposed, i. e., the quantification of the relationships between the fire behaviors and environmental factors and the post-fire debris flow, the quantitative research on the post-fire debris flow initiation and movement processes, the mechanistic model of post-fire debris flow, and the rapid and efficient control countermeasures of post-fire debris flow.

  17. Review of Constructed Subsurface Flow vs. Surface Flow Wetlands

    International Nuclear Information System (INIS)

    HALVERSON, NANCY

    2004-01-01

    The purpose of this document is to use existing documentation to review the effectiveness of subsurface flow and surface flow constructed wetlands in treating wastewater and to demonstrate the viability of treating effluent from Savannah River Site outfalls H-02 and H-04 with a subsurface flow constructed wetland to lower copper, lead and zinc concentrations to within National Pollutant Discharge Elimination System (NPDES) Permit limits. Constructed treatment wetlands are engineered systems that have been designed and constructed to use the natural functions of wetlands for wastewater treatment. Constructed wetlands have significantly lower total lifetime costs and often lower capital costs than conventional treatment systems. The two main types of constructed wetlands are surface flow and subsurface flow. In surface flow constructed wetlands, water flows above ground. Subsurface flow constructed wetlands are designed to keep the water level below the top of the rock or gravel media, thus minimizing human and ecological exposure. Subsurface flow wetlands demonstrate higher rates of contaminant removal per unit of land than surface flow (free water surface) wetlands, therefore subsurface flow wetlands can be smaller while achieving the same level of contaminant removal. Wetlands remove metals using a variety of processes including filtration of solids, sorption onto organic matter, oxidation and hydrolysis, formation of carbonates, formation of insoluble sulfides, binding to iron and manganese oxides, reduction to immobile forms by bacterial activity, and uptake by plants and bacteria. Metal removal rates in both subsurface flow and surface flow wetlands can be high, but can vary greatly depending upon the influent concentrations and the mass loading rate. Removal rates of greater than 90 per cent for copper, lead and zinc have been demonstrated in operating surface flow and subsurface flow wetlands. The constituents that exceed NPDES limits at outfalls H-02 a nd H

  18. Characterization of an acidification and equalization tank (AET operating as a primary treatment of swine liquid effluent

    Directory of Open Access Journals (Sweden)

    Fabrício Motteran

    2013-06-01

    Full Text Available This work evaluated the potential of the acidification equalization tank (AET used as a primary treatment unit, treating the hog farming wastewater. The treatment system consisted of a degritter with a triangular-notch weir, for measuring the flow, a static sieve, and an acidification and equalization tank (AET, an anaerobic baffled reactor (ABR, an upflow anaerobic sludge blanket (UASB reactor, a settling tank, a greenhouse for fertirrigation and two infiltration ponds. The AET had a net capacity of 8,000 liters, internally covered with asphalt blanket, worked based on surface loading rates application. The unit operated continuously, with its flow varying from 0.1 to 10 L s-1. To determine the efficiency, the following parameters were measured: pH; COD; BOD; volatile and fixed solids; settleable solids; total, intermediate and partial alkalinity and total acidity. The COD removal varied from 5 to 20%. The average pH was 7.3 and the total, intermediate and partial alkalinity in the effluent, were 1919, 846, 1197 mg L-1, respectively. The total acidity in the effluent was 34 mg L-1. The influent and effluent total BOD and oil & grease concentrations were 3436 and 3443 mg L-1, and 415 and 668 mg L-1, respectively. It was found that the AET worked properly concerning the acidification, equalization and sedimentation processes, confirming low cost of implementation and easy operation, when compared to other traditional decanters.

  19. Scale-up of a mixer-settler extractor using a unit operations approach

    International Nuclear Information System (INIS)

    Lindholm, D.C.; Bautista, R.G.

    1976-01-01

    The results of scale-up studies on a continuous, multistage horizontal mixer-settler extractor are presented. The chemical and mechanical system involves the separation of lanthanum from a mixture of rare earth chlorides using di(2-ethylhexyl) phosphoric acid as the solvent and dilute HCl as a scrub solution in a bench scale extractor. Each stage has a hold-up of 2.6 l. A single stage unit is utilized for scale-up studies. Results are obtained on four sizes of geometrically similar units, the largest being six times the volume of the original bench size. A unit operations technique is chosen so that mixing and settling can be examined independently. Variables examined include type of continuous phase, flow rate of inlet streams, and power input to the mixer. Inlet flow-rate ratios are kept constant for all tests. Two potential methods of unbaffled pump-mixer scale-up are explored; the maintenance of constant impeller tip speed and constant power input. For the settler, the previously successful method of basing design on constant flow-rate per unit cross-sectional area is used

  20. Transverse injection into Mach 2 flow behind a rearward-facing step - A 3-D, compressible flow test case for hypersonic combustor CFD validation

    Science.gov (United States)

    Mcdaniel, James C.; Fletcher, Douglas G.; Hartfield, Roy J.; Hollo, Steven D.

    1991-01-01

    A spatially-complete data set of the important primitive flow variables is presented for the complex, nonreacting, 3D unit combustor flow field employing transverse injection into a Mach 2 flow behind a rearward-facing step. A unique wind tunnel facility providing the capability for iodine seeding was built specifically for these measurements. Two optical techniques based on laser-induced-iodine fluorescence were developed and utilized for nonintrusive, in situ flow field measurements. LDA provided both mean and fluctuating velocity component measurements. A thermographic phosphor wall temperature measurement technique was developed and employed. Data from the 2D flow over a rearward-facing step and the complex 3D mixing flow with injection are reported.

  1. Primary prevention in psychiatry in general hospitals in South Asia

    Science.gov (United States)

    Sood, Mamta; Chadda, Rakesh Kumar; Kallivayalil, Roy Abraham

    2017-01-01

    The focus of primary prevention is on reducing the disease incidence. Primary prevention in mental health has been given minimal priority in low-resource settings with no significant investments. General hospitals are one of the main providers of mental health services in South Asia. This paper focuses on primary prevention activities, which can be undertaken in a general hospital in South Asia with abysmally low-mental health resources. For implementing primary prevention in psychiatry, a general hospital may be conceptualized as a population unit, located in a well-populated area with easy accessibility where different kinds of communities, for example, students and resident doctors, consultants, patients and their caregivers, and paramedical, nursing, administrative and other supportive staff, coexist and have varied functions. All the functional components of the general hospital psychiatric units (GHPUs) offer scope for introducing primary preventive psychiatry services. Psychiatrists in GHPUs can lead efforts for primary prevention in mental health in the hospital by employing strategies in the framework of universal, selective, and indicated prevention. The preventive strategies could be targeted at the patients visiting the hospital for various health services and their caregivers, employees, and the trainees. Similar principles can be employed in teaching and training. PMID:29497199

  2. Aquifer test plan for the 100-HR-3 Operable Unit

    International Nuclear Information System (INIS)

    Swanson, L.C.; Hartman, M.J.

    1994-01-01

    This test plan directs hydrologic testing activities planned at three existing Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) wells in the 100-HR-3 Operable Unit of the Hanford Site. Three additional wells will be installed near these existing wells and used as additional testing arid observation points during the field activities. Figure 1 shows the locations of the three test sites. A primary objective of the testing program is to provide more detailed hydraulic characterization information for the unconfined aquifer and targeted test sites than provided by the initial reconnaissance-level slug testing of Vukelich. A second objective is to evaluate the applicability of slug interference and dipole flow tests for detailed hydraulic characterization in an unconfined aquifer. This aquifer testing program will also be useful for substantiating hydraulic conductivities reported from previous slug tests and evaluating the effects of filter pack volume/configuration on slug test data. Vukelich recommended additional testing to address the latter two issues

  3. Language-Based Reasoning in Primary Science

    Science.gov (United States)

    Hackling, Mark; Sherriff, Barbara

    2015-01-01

    Language is critical in the mediation of scientific reasoning, higher-order thinking and the development of scientific literacy. This study investigated how an exemplary primary science teacher scaffolds and supports students' reasoning during a Year 4 materials unit. Lessons captured on video, teacher and student interviews and micro-ethnographic…

  4. Relationship between leadership styles of hospital pharmacists and perceptions of work-unit effectiveness.

    Science.gov (United States)

    Bennett, C R; Grussing, P G; Hutchinson, R A; Stewart, J E

    1988-08-01

    Relationships between hospital pharmacists' perceptions of their own and their immediate supervisors' leadership styles and their perceptions of the effectiveness of their work units were examined. Pharmacists practicing in 12 large Chicago-area hospitals were asked to complete a four-part questionnaire that consisted of demographic questions, the LEADSelf instrument, the LEADOther instrument, and a measure of perceived work unit effectiveness. Respondents' primary, secondary, and combination leadership styles and their degree of style adaptability were determined and compared with the primary, secondary, and combination leadership styles and style adaptability of their immediate supervisors and with their perceptions of the effectiveness of their work units. Pharmacists involved in providing clinical or drug information services and pharmacists responsible for purchasing activities perceived their work units to be most and least effective, respectively. Most respondents perceived their primary leadership style to be high task-high relationship, but only 32% perceived their immediate supervisors to exhibit this style. Pharmacists who perceived their immediate supervisors to have high relationship leadership styles (based on primary and combination style classifications) had significantly more favorable perceptions of the effectiveness of their work units than did pharmacists who perceived their supervisors to exhibit low relationship styles. Respondents' perceptions of their supervisors' style adaptability were positively and significantly correlated with their perceptions of work-unit effectiveness. Respondents who thought their supervisors' leadership styles were more adaptable than their own had the most favorable perceptions of work-unit effectiveness.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Ambient groundwater flow diminishes nitrogen cycling in streams

    Science.gov (United States)

    Azizian, M.; Grant, S. B.; Rippy, M.; Detwiler, R. L.; Boano, F.; Cook, P. L. M.

    2017-12-01

    Modeling and experimental studies demonstrate that ambient groundwater reduces hyporheic exchange, but the implications of this observation for stream N-cycling is not yet clear. We utilized a simple process-based model (the Pumping and Streamline Segregation or PASS model) to evaluate N- cycling over two scales of hyporheic exchange (fluvial ripples and riffle-pool sequences), ten ambient groundwater and stream flow scenarios (five gaining and losing conditions and two stream discharges), and three biogeochemical settings (identified based on a principal component analysis of previously published measurements in streams throughout the United States). Model-data comparisons indicate that our model provides realistic estimates for direct denitrification of stream nitrate, but overpredicts nitrification and coupled nitrification-denitrification. Riffle-pool sequences are responsible for most of the N-processing, despite the fact that fluvial ripples generate 3-11 times more hyporheic exchange flux. Across all scenarios, hyporheic exchange flux and the Damkohler Number emerge as primary controls on stream N-cycling; the former regulates trafficking of nutrients and oxygen across the sediment-water interface, while the latter quantifies the relative rates of organic carbon mineralization and advective transport in streambed sediments. Vertical groundwater flux modulates both of these master variables in ways that tend to diminish stream N-cycling. Thus, anthropogenic perturbations of ambient groundwater flows (e.g., by urbanization, agricultural activities, groundwater mining, and/or climate change) may compromise some of the key ecosystem services provided by streams.

  6. Flow Giese reaction using cyanoborohydride as a radical mediator

    Directory of Open Access Journals (Sweden)

    Takahide Fukuyama

    2013-09-01

    Full Text Available Tin-free Giese reactions, employing primary, secondary, and tertiary alkyl iodides as radical precursors, ethyl acrylate as a radical trap, and sodium cyanoborohydride as a radical mediator, were examined in a continuous flow system. With the use of an automated flow microreactor, flow reaction conditions for the Giese reaction were quickly optimized, and it was found that a reaction temperature of 70 °C in combination with a residence time of 10–15 minutes gave good yields of the desired addition products.

  7. A century of changing flows: Forest management changed flow magnitudes and warming advanced the timing of flow in a southwestern US river.

    Directory of Open Access Journals (Sweden)

    Marcos D Robles

    Full Text Available The continued provision of water from rivers in the southwestern United States to downstream cities, natural communities and species is at risk due to higher temperatures and drought conditions in recent decades. Snowpack and snowfall levels have declined, snowmelt and peak spring flows are arriving earlier, and summer flows have declined. Concurrent to climate change and variation, a century of fire suppression has resulted in dramatic changes to forest conditions, and yet, few studies have focused on determining the degree to which changing forests have altered flows. In this study, we evaluated changes in flow, climate, and forest conditions in the Salt River in central Arizona from 1914-2012 to compare and evaluate the effects of changing forest conditions and temperatures on flows. After using linear regression models to remove the influence of precipitation and temperature, we estimated that annual flows declined by 8-29% from 1914-1963, coincident with a 2-fold increase in basal area, a 2-3-fold increase in canopy cover, and at least a 10-fold increase in forest density within ponderosa pine forests. Streamflow volumes declined by 37-56% in summer and fall months during this period. Declines in climate-adjusted flows reversed at mid-century when spring and annual flows increased by 10-31% from 1964-2012, perhaps due to more winter rainfall. Additionally, peak spring flows occurred about 12 days earlier in this period than in the previous period, coincident with winter and spring temperatures that increased by 1-2°C. While uncertainties remain, this study adds to the knowledge gained in other regions that forest change has had effects on flow that were on par with climate variability and, in the case of mid-century declines, well before the influence of anthropogenic warming. Current large-scale forest restoration projects hold some promise of recovering seasonal flows.

  8. Predictors of CPAP compliance in different clinical settings: primary care versus sleep unit.

    Science.gov (United States)

    Nadal, Núria; de Batlle, Jordi; Barbé, Ferran; Marsal, Josep Ramon; Sánchez-de-la-Torre, Alicia; Tarraubella, Nuria; Lavega, Merce; Sánchez-de-la-Torre, Manuel

    2018-03-01

    Good adherence to continuous positive airway pressure (CPAP) treatment improves the patient's quality of life and decreases the risk of cardiovascular disease. Previous studies that have analyzed the adherence to CPAP were performed in a sleep unit (SU) setting. The involvement of primary care (PC) in the management of obstructive sleep apnea (OSA) patients receiving CPAP treatment could introduce factors related to the adherence to treatment. The objective was to compare the baseline predictors of CPAP compliance in SU and PC settings. OSA patients treated with CPAP were followed for 6 months in SU or PC setting. We included baseline clinical and anthropometrical variables, the Epworth Sleep Scale (ESS) score, the quality of life index, and the Charlson index. A logistic regression was performed for each group to determine the CPAP compliance predictors. Discrimination and calibration were performed using the area under the curve and Hosmer-Lemeshow tests. We included 191 patients: 91 in the PC group and 100 in the SU group. In 74.9% of the patients, the compliance was ≥ 4 h per day, with 80% compliance in the SU setting and 69.2% compliance in the PC setting (p = 0.087). The predictors of CPAP compliance were different between SU and PC settings. Body mass index, ESS, and CPAP pressure were predictors in the SU setting, and ESS, gender, and waist circumference were predictors in the PC setting. The predictors of adequate CPAP compliance vary between SU and PC settings. Detecting compliance predictors could help in the planning of early interventions to improve CPAP adherence.

  9. Immobilization of Tyrosinase on (3-Aminopropyltriethoxysilane-Functionalized Carbon Felt-Based Flow-Through Detectors for Electrochemical Detection of Phenolic Compounds

    Directory of Open Access Journals (Sweden)

    Zheng Zhou

    2017-07-01

    Full Text Available Tyrosinase (TYR was covalently immobilized onto amino-functionalized carbon felt (CF surface via glutaraldehyde (GA. Prior to the TYR-immobilization, primary amino group was introduced to the CF surface by treatment with 3-aminopropyltriethoxysilane (APTES. The resulting TYR-immobilized CF was used as a working electrode unit of an electrochemical flow-through detector for mono- and di-phenolic compounds (i.e., catechol, p-cresol, phenol and p-chlorophenol. Additionally, flow injection peaks based on electroreduction of the enzymatically produced o-quinone species were detected at −0.05 V vs. Ag/AgCl. The resulting TYR/GA/APTES/CF biosensor responded well to all compounds tested with limits of detection range from 7.5 to 35 nmol−1 (based on three times S/N ratio. Moreover, such modified electrode exhibits good stability and reproducibility for catechol. No serious degradation of the peak current was found over 30 consecutive injections.

  10. Numerical Study on the Helium Flow Characteristics for Steam Generator Subsystem of HTR

    International Nuclear Information System (INIS)

    Ha, Jung Hoon; Ham, Jin Ki; Ki, Min-Hwan; Lee, Won Jae

    2014-01-01

    The High Temperature Reactor (HTR), one of the 4th generation reactors, utilizes helium as the primary coolant. A Steam Generator Subsystem (SGS) is installed to transfer heat from the primary coolant to feed water and subsequently produce steam so that it supplies electricity as well as process heat over a wide range. The SGS is composed of a helical heat exchanger, shrouds directing the flow of the shell side helium and support systems, which are located within the steam generator vessel. In this study, helium flow characteristics in the SGS were investigated at various operating conditions using Computational Fluid Dynamics (CFD). A full-scale 3-D model of the SGS was developed and the reynolds stress model with standard wall treatment was used as a turbulence model. The CFD result was compared to that of the concept design of the steam cycle modular helium reactor for the design verification of the SGS. From the CFD analysis, it was found that the primary coolant flow had non-uniform distribution while it passed the inlet in the helical heat exchanger. In order to make the uniform primary coolant flow uniform, a special type of screen was suggested in front of the helical heat exchanger. As a result, the overall design adequacy of the SGS has been evaluated. (author)

  11. Oxy-fired boiler unit and method of operating the same

    Science.gov (United States)

    Lou, Xinsheng; Zhang, Jundong; Joshi, Abhinaya; McCombe, James A.; Levasseur, Armand A.

    2016-12-06

    An oxy-combustion boiler unit is disclosed which includes a furnace for combusting fuel and for emitting flue gas resulting from combustion. The furnace has first, second and third combustion zones, and an air separation unit for separating oxygen gas from air and providing a first portion of the separated oxygen to a first oxidant flow, a second portion to a second oxidant flow, and a third portion of the separated oxygen gas to the first, second, and third zones of the furnace. A controller can cause the separated oxygen gas to be distributed so that the first and second oxygen flows have a desired oxygen content, and so that the first, second, and third zones of the furnace receive a desired amount of oxygen based on a combustion zone stoichiometry control.

  12. Prognostic value of flow cytometry in surgically treated primary gastric lymphoma Valor pronóstico de la citometría de flujo en el linfoma gástrico

    Directory of Open Access Journals (Sweden)

    F. Fernández

    2006-11-01

    Full Text Available Aim: to investigate whether flow cytometry could help to define the optimal therapeutic strategy of primary gastric lymphomas. Material and method: retrospective study of 46 patients having primary gastric lymphoma -according to Dawson criteria- in Ann Arbor stage I E and II E, who were surgically treated. From selected paraffin-embedded tissue blocks of the tumor, DNA content was studied by flow cytometry (FC. Other pathological tumor features were analysed by hematoxiline-eosine and Giemsa stains as well as immunohistochemical study; any possible influence on postoperative survival was investigated through statistical analysis. Results: the DNA ploidy pattern was diploid in 40 cases (87% and aneuploid (hyperdiploid in 6 (13%. Postoperative survival probability (PSP was 62.7% at 5 years. Statistical analysis showed significant prognostic value for Ann Arbor classification -with higher PSP for stage I E (p = 0.009- and FC parameters: diploid tumors had higher PSP than aneuploid tumors. Also tumors having S-phase (p = 0.044 or G2-M phase values (p = 0.023 under the respective mean values had higher PSP. No influence on PSP was found for wall invasion, Helicobacter pylori infection, Isaacson's histologic type or resection margin involvement. No significant relationship was appreciated between Isaacson's histologic type and DNA ploidy patterns. Conclusion: FC could be useful in assessing gastric lymphoma prognosis.

  13. Analysis and design of flow limiter used in steam generator

    International Nuclear Information System (INIS)

    Liu Shixun; Gao Yongjun

    1995-10-01

    Flow limiter is an important safety component of PWR steam generator. It can limit the blowdown rate of steam generator inventory in case of the main steam pipeline breaks, so that the rate of the primary coolant temperature reduction can be slowed down in order to prevent fuel element from burn-out. The venturi type flow limiter is analysed, its flow characteristics are delineated, physical and mathematical models defined; the detail mathematical derivation provided. The research lays down a theoretic basis for flow limiter design. The governing equations and formulas given can be directly applied to computer analysis of the flow limiter. (3 refs., 3 figs.)

  14. Automatic TV X-ray unit for testing aluminium castings

    International Nuclear Information System (INIS)

    Morgunov, V.I.; Firstov, V.G.; Kisin, V.I.; Savostenok, M.I.

    1989-01-01

    The automatic TV X-ray unit for testing of aluminum alloy castings in a flow is described. The unit includes RAP-150/300 X-ray apparatus and PI-60TK TV X-ray device. The biological protection chamber and the common control board are the main functional units. The tests of the unit have shown that as regards its characteristics it is not worse than its foreign-made analogues, for example, devices of the DP-35 and DP-38 type of the 'Seifert' company

  15. Measurement of cerebral blood flow rate and its relationship with brain function using optical coherence tomography

    Science.gov (United States)

    Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe

    2016-03-01

    Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.

  16. Primary Energy of the District city and Suburb

    Science.gov (United States)

    Pitonak, Anton; Lopusniak, Martin; Bagona, Miloslav

    2017-10-01

    In member states of the European Union, portion of buildings in the total consumption of energy represents 40 %, and their share in CO2 emissions represents 35 %. Taking into account the dependence of the European Union on import of energy, this represents a large quantity of energy and CO2 in spite of the fact that effective solutions for the reduction of energy demand of buildings exist. The European Union adopted three main commitments for fulfilment of criteria by year 2020 in the 20-20-20 Directive. Based on this Directive Slovakia declares support for renovating the building stock. The goal of the paper was to prove that renovation of the building stock is environmentally and energy preferably as construction of new buildings. In the paper, the settlement unit with the suburban one were compared. Both territories are dealt with in Kosice city, in Slovakia. The settlement units include apartment dwelling houses, amenities, parking areas and green. Suburban part contains family houses. The decisive factor for the final assessment of the buildings was global indicator. Global indicator of the energy performance is primary energy. The new building must meet minimum requirements for energy performance and it must be classified to energy class A1 since 2016, and to energy class A0 since 2020. The paper analyses the effects of the use of different resources of heat considering the global indicator. Primary energy was calculated and based on comparable unit. The primary energy was accounted for on the built-up area, area corresponding to district city and suburb, number of inhabitants. The study shows that the lowest values of global indicator are achieved by using wood. The highest values of global indicator are achieved by using electricity or district heating as an energy source. The difference between the highest and lowest value is 87 %. Primary energy based on inhabitant is 98 % lower in settlement unit compared to the suburban one.

  17. Method of coupling 1-D unsaturated flow with 3-D saturated flow on large scale

    Directory of Open Access Journals (Sweden)

    Yan Zhu

    2011-12-01

    Full Text Available A coupled unsaturated-saturated water flow numerical model was developed. The water flow in the unsaturated zone is considered the one-dimensional vertical flow, which changes in the horizontal direction according to the groundwater table and the atmospheric boundary conditions. The groundwater flow is treated as the three-dimensional water flow. The recharge flux to groundwater from soil water is considered the bottom flux for the numerical simulation in the unsaturated zone, and the upper flux for the groundwater simulation. It connects and unites the two separated water flow systems. The soil water equation is solved based on the assumed groundwater table and the subsequent predicted recharge flux. Then, the groundwater equation is solved with the predicted recharge flux as the upper boundary condition. Iteration continues until the discrepancy between the assumed and calculated groundwater nodal heads have a certain accuracy. Illustrative examples with different water flow scenarios regarding the Dirichlet boundary condition, the Neumann boundary condition, the atmospheric boundary condition, and the source or sink term were calculated by the coupled model. The results are compared with those of other models, including Hydrus-1D, SWMS-2D, and FEFLOW, which demonstrate that the coupled model is effective and accurate and can significantly reduce the computational time for the large number of nodes in saturated-unsaturated water flow simulation.

  18. Policy Levers Key for Primary Health Care Organizations to Support Primary Care Practices in Meeting Medical Home Expectations: Comparing Leading States to the Australian Experience

    OpenAIRE

    Takach, Mary

    2016-01-01

    Abstract Several countries with highly ranked delivery systems have implemented locally-based, publicly-funded primary health care organizations (PHCOs) as vehicles to strengthen their primary care foundations. In the United States, state governments have started down a similar pathway with models that share similarities with international PHCOs. The objective of this study was to determine if these kinds of organizations were working with primary care practices to improve their ability to pr...

  19. Application of computer code ALMOD in transient analysis with reverse flow in the primary loop of nuclear power plant; Primjena programa ALMOD u analizi prijelaznih pojava sa reverzibilnim protokom u primarnom krugu nuklerne elektrane

    Energy Technology Data Exchange (ETDEWEB)

    Bencik, V [Elektrotehnicki Institut ' Rade Koncar' , Zagreb (Yugoslavia); Feretic, D; Debrecin, N [Elektrotehnicki fakultet, Zagreb (Yugoslavia)

    1989-07-01

    A computer code ALMOD 3W3 to analyze the transients in which reverse flow in the primary loop of nuclear power plant may occur has been developed. The method to calculate the fluid dynamics in NRC system is presented. The locked rotor accident in one coolant loop is analyzed. (author)

  20. Cooperative observations of air showers in Tasmania looking for anisotropies in 10 to the 13th - 10 to the 14th eV primaries /COALA project/

    Science.gov (United States)

    Fenton, A. G.; Fenton, K. B.; Humble, J. E.; Jacklyn, R. M.; Vrana, A.; Murakami, K.; Fujii, Z.; Yamada, T.; Sakakibara, S.; Fujimoto, K.; Ueno, H.; Nagashima, K.; Kondo, I.

    Observations of cosmic ray air showers in Tasmania beginning in 1981 are discussed. The shower array consists of 18 unit trays of 4-sq m proportional counters deployed over an area of 20 m x 160 m, and showers around a median primary energy of 5 x 10 to the 13th are to be observed. The observations are carried out in order to catch cosmic ray flows in a stereoscopic manner with simultaneous observations in the northern hemisphere, and the shower frequency in a fundamental coincidence mode is expected to be about 16,000 events per year.