WorldWideScience

Sample records for primary chest tube

  1. Surgical treatment versus conventional chest tube drainage in primary spontaneous pneumothorax

    DEFF Research Database (Denmark)

    Olesen, Winnie Hedevang; Katballe, Niels; Sindby, Jesper Eske

    2018-01-01

    OBJECTIVES: Primary spontaneous pneumothorax frequently recurs after chest tube management. Evidence is lacking whether patients may benefit from surgery following their first episode. METHODS: We performed a multicentre, randomized trial and enrolled young, otherwise healthy patients admitted...... with their first episode of primary spontaneous pneumothorax and treated using conventional chest tube drainage. Patients underwent high-resolution computed tomography on fully expanded lungs, and using web-based randomization, we assigned patients to continued conservative chest tube treatment or chest tube...... treatment to prevent recurrence in patients with their first presentation of primary spontaneous pneumothorax and should be the standard of care when high-resolution computed tomography demonstrates bullae ≥2 cm. Clinical trial registration: ClinicalTrial.gov: NCT 02866305....

  2. The influence of chest tube size and position in primary spontaneous pneumothorax

    DEFF Research Database (Denmark)

    Riber, Sara S.; Riber, Lars P S; Olesen, Winnie H.

    2017-01-01

    Background: Optimal chest tube position in the pleural cavity is largely unexplored for the treatment of primary spontaneous pneumothorax (PSP). We investigated whether type, size and position of chest tubes influenced duration of treatment for PSP. Methods: A retrospective follow-up study of all...... patients admitted with PSP over a 5-year period. Traumatic, iatrogenic and secondary pneumothoraxes were excluded. Gender, age, smoking habits, type and size of chest tube used (pigtail catheter or surgical chest tube) were recorded from the patients' charts. All chest X-rays upon admittance...... and immediately following chest tube placement were retrieved and re-evaluated for size of pneumothorax (categorized into five groups) and location of the chest tube tip (categorized as upper, middle or lower third of the pleural cavity). All data were analysed in a Cox proportional hazards regression model...

  3. A Novel Device for Accurate Chest Tube Insertion

    DEFF Research Database (Denmark)

    Katballe, Niels; Moeller, Lars B; Olesen, Winnie H

    2016-01-01

    BACKGROUND: Optimal positioning of a large-bore chest tube is in the part of the pleural cavity that needs drainage. It is recommended that the chest tube be positioned apically in pneumothorax and basally for fluids. However, targeted chest tube positioning to a specific part of the pleural cavity...... can be a challenge. METHODS: A new medical device, the KatGuide, was developed for accurate guiding of a chest tube (28F) to an intended part of the pleural cavity. The primary end point of this randomized, controlled trial was optimal position of the chest tube. The optimal position in pneumothorax...

  4. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  5. Recurrent Primary Spontaneous Pneumothorax is Common Following Chest Tube and Conservative Treatment

    DEFF Research Database (Denmark)

    Olesen, Winnie Hedevang; Lindahl-Jacobsen, Rune; Katballe, Niels

    2016-01-01

    INTRODUCTION: Previous studies on primary spontaneous pneumothorax reported variable recurrence rates, but they were based on heterogeneous patient populations including secondary pneumothorax. We investigated young patients with primary spontaneous pneumothorax exclusively and used a national...... registry to track readmissions and calculate independent predictors of recurrence. METHODS: A prospective cohort study of consecutive young patients who were admitted over a 5-year period with their first episode of primary spontaneous pneumothorax and treated conservatively with a chest tube. Baseline...... characteristics were obtained from questionnaires presented on admittance. All patients were discharged with fully expanded lungs on chest radiography. Patient charts were identified in the national electronic patient registry for detailed information on readmissions due to recurrent spontaneous pneumothorax...

  6. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  8. Chest tube placement in thorax trauma - comparison chest X-ray and computed tomography (CT)

    International Nuclear Information System (INIS)

    Heim, P.; Maas, R.; Buecheler, E.; Tesch, C.

    1998-01-01

    Estimation of chest tube placement in patients with thoracic trauma with regard to chest tube malposition in chest radiography in the supine position compared to additional computed tomography of the thorax. Material and methods: Apart from compulsory chest radiography after one or multiple chest tube insertions, 31 severely injured patients with thoracic trauma underwent a CT scan of the thorax. These 31 patients with 40 chest tubes constituted the basis for the present analysis. Results: In chest radiography in the supine position there were no chest tube malpositions (n=40); In the CT scans 25 correct positions, 7 pseudo-malpositions, 6 intrafissural and 2 intrapulmonary malpositions were identified. Moreover 16 sufficient, 18 insufficient and 6 indifferent functions of the chest tubes were seen. Conclusion: In case of lasting clinical problems and questionable function of the chest tube, chest radiography should be supplemented by a CT scan of the thorax in order to estimate the position of the chest tube. (orig.) [de

  9. Recurrent Primary Spontaneous Pneumothorax is Common Following Chest Tube and Conservative Treatment.

    Science.gov (United States)

    Olesen, Winnie Hedevang; Lindahl-Jacobsen, Rune; Katballe, Niels; Sindby, Jesper Eske; Titlestad, Ingrid Louise; Andersen, Poul Erik; Licht, Peter Bjørn

    2016-09-01

    Previous studies on primary spontaneous pneumothorax reported variable recurrence rates, but they were based on heterogeneous patient populations including secondary pneumothorax. We investigated young patients with primary spontaneous pneumothorax exclusively and used a national registry to track readmissions and calculate independent predictors of recurrence. A prospective cohort study of consecutive young patients who were admitted over a 5-year period with their first episode of primary spontaneous pneumothorax and treated conservatively with a chest tube. Baseline characteristics were obtained from questionnaires presented on admittance. All patients were discharged with fully expanded lungs on chest radiography. Patient charts were identified in the national electronic patient registry for detailed information on readmissions due to recurrent spontaneous pneumothorax. We included 234 patients. Male/female = ratio 5/1. After a median observation period of 3.6 years (range 1-6 years), recurrent pneumothorax was observed in 54 %. Ipsilateral recurrence was the most common (79 %) but 30 % also experienced contralateral pneumothorax during the study period. Females had a significantly higher age at debut (p pneumothorax in younger patients with their first episode had a much higher recurrence rate than previously reported. Every doctor who treats patients with primary spontaneous pneumothorax should be aware and patients informed.

  10. Improved drainage with active chest tube clearance.

    Science.gov (United States)

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. The single chest tube versus double chest tube application after pulmonary lobectomy: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Xuefei Zhang

    2016-01-01

    Conclusion: Compared with the double chest tube, the single chest tube significantly decreases amount of drainage, duration of chest tube drainage, pain score, the number of patients who need thoracentesis, and cost. Although there is convincing evidence to confirm the results mentioned herein, they still need to be confirmed by large-sample, multicenter, randomized, controlled trials.

  12. Management of chest drainage tubes after lung surgery.

    Science.gov (United States)

    Satoh, Yukitoshi

    2016-06-01

    Since chest tubes have been routinely used to drain the pleural space, particularly after lung surgery, the management of chest tubes is considered to be essential for the thoracic surgeon. The pleural drainage system requires effective drainage, suction, and water-sealing. Another key point of chest tube management is that a water seal is considered to be superior to suction for most air leaks. Nowadays, the most common pleural drainage device attached to the chest tube is the three-bottle system. An electronic chest drainage system has been developed that is effective in standardizing the postoperative management of chest tubes. More liberal use of digital drainage devices in the postoperative management of the pleural space is warranted. The removal of chest tubes is a common procedure occurring almost daily in hospitals throughout the world. Extraction of the tube is usually done at the end of full inspiration or at the end of full expiration. The tube removal technique is not as important as how it is done and the preparation for the procedure. The management of chest tubes must be based on careful observation, the patient's characteristics, and the operative procedures that had been performed.

  13. [How to do - the chest tube drainage].

    Science.gov (United States)

    Klopp, Michael; Hoffmann, Hans; Dienemann, Hendrik

    2015-03-01

    A chest tube is used to drain the contents of the pleural space to reconstitute the physiologic pressures within the pleural space and to allow the lungs to fully expand. Indications for chest tube placement include pneumothorax, hemothorax, pleural effusion, pleural empyema, and major thoracic surgery. The most appropriate site for chest tube placement is the 4th or 5th intercostal space in the mid- or anterior- axillary line. Attention to technique in placing the chest tube is vital to avoid complications from the procedure. Applying the step-by-step technique presented, placement of a chest tube is a quick and safe procedure. Complications - frequently occurring when the tube is inserted with a steel trocar - include hemothorax, dislocation, lung lacerations, and injury to organs in the thoracic or abdominal cavity." © Georg Thieme Verlag KG Stuttgart · New York.

  14. Chest tube drainage of transudative pleural effusions hastens liberation from mechanical ventilation.

    Science.gov (United States)

    Kupfer, Yizhak; Seneviratne, Chanaka; Chawla, Kabu; Ramachandran, Kavan; Tessler, Sidney

    2011-03-01

    Pleural effusions occur frequently in patients requiring mechanical ventilatory support. Treatment of the precipitating cause and resolution of the pleural effusion may take considerable time. We retrospectively studied the effect of chest tube drainage of transudative pleural effusions on the liberation of patients from mechanical ventilatory support. Patients in the medical ICU (MICU) at Maimonides Medical Center between January 1, 2009, and October 31, 2009, requiring mechanical ventilatory support with a transudative pleural effusion, were studied retrospectively. They were divided into two groups: standard care and standard care plus chest tube drainage. Chest tubes were placed under ultrasound guidance by trained intensivists. Duration of mechanical ventilatory support was the primary end point. Secondary end points included measures of oxygenation, amount of fluid drained, and complications associated with the chest tube. A total of 168 patients were studied; 88 were treated with standard care and 80 underwent chest tube drainage. Total duration of mechanical ventilatory support was significantly shorter for patients who had chest tube drainage: 3.8±0.5 days vs 6.5±1.1 days for the standard group (P=.03). No differences in oxygenation were noted between the two groups. The average amount of fluid drained was 1,220 mL. No significant complications were caused by chest tube drainage. Chest tube drainage of transudative pleural effusions resulted in more rapid liberation from mechanical ventilatory support. It is a very safe procedure when performed under ultrasound guidance by experienced personnel. ClinicalTrials.gov; Identifier: NCT0114285; URL: www.clinicaltrials.gov.

  15. Electronic versus traditional chest tube drainage following lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Licht, Peter B; Neckelmann, Kirsten

    2015-01-01

    thoracic surgery, we conducted a randomized controlled trial (RCT) investigating chest tube duration and length of hospitalization. METHODS: Patients undergoing lobectomy were included in a prospective open label RCT. A strict algorithm was designed for early chest tube removal, and this decision...... was delegated to staff nurses. Data were analysed by Cox proportional hazard regression model adjusting for lung function, gender, age, BMI, video-assisted thoracic surgery (VATS) or open surgery and presence of incomplete fissure or pleural adhesions. Time was distinguished as possible (optimal) and actual.......014). CONCLUSIONS: Electronic drainage systems did not reduce chest tube duration or length of hospitalization significantly compared with traditional water seal drainage when a strict algorithm for chest tube removal was used. This algorithm allowed delegation of chest tube removal to staff nurses, and in some...

  16. Single chest tube drainage is superior to double chest tube drainage after lobectomy: a meta-analysis.

    Science.gov (United States)

    Zhou, Dong; Deng, Xu-Feng; Liu, Quan-Xing; Chen, Qian; Min, Jia-Xin; Dai, Ji-Gang

    2016-05-27

    In this meta-analysis, we conducted a pooled analysis of clinical studies comparing the efficacy of single chest tube versus double chest tube after a lobectomy. According to the recommendations of the Cochrane Collaboration, we established a rigorous study protocol. We performed a systematic electronic search of the PubMed, Embase, Cochrane Library and Web of Science databases to identify articles to include in our meta-analysis. A literature search was performed using relevant keywords. A meta-analysis was performed using RevMan© software. Five studies, published between 2003 and 2014, including 630 patients (314 patients with a single chest tube and 316 patients with a double chest tube), met the selection criteria. From the available data, the patients using a single tube demonstrated significantly decreased postoperative pain [weighted mean difference [WMD] -0.60; 95 % confidence intervals [CIs] -0.68-- 0.52; P tube after a pulmonary lobectomy. However, there were no significant differences in postoperative complications [OR 0.91; 95 % CIs 0.57-1.44; P = 0.67] and re-drainage rates [OR 0.81; 95 % CIs 0.42-1.58; P = 0.54]. Our results showed that a single-drain method is effective, reducing postoperative pain, hospitalization times and duration of drainage in patients who undergo a lobectomy. Moreover, the single-drain method does not increase the occurrence of postoperative complications and re-drainage rates.

  17. Thin chest wall is an independent risk factor for the development of pneumothorax after chest tube removal.

    Science.gov (United States)

    Anand, Rahul J; Whelan, James F; Ferrada, Paula; Duane, Therese M; Malhotra, Ajai K; Aboutanos, Michel B; Ivatury, Rao R

    2012-04-01

    The factors contributing to the development of pneumothorax after removal of chest tube thoracostomy are not fully understood. We hypothesized that development of post pull pneumothorax (PPP) after chest tube removal would be significantly lower in those patients with thicker chest walls, due to the "protective" layer of adipose tissue. All patients on our trauma service who underwent chest tube thoracostomy from July 2010 to February 2011 were retrospectively reviewed. Patient age, mechanism of trauma, and chest Abbreviated Injury Scale score were analyzed. Thoracic CTs were reviewed to ascertain chest wall thickness (CW). Thickness was measured at the level of the nipple at the midaxillary line, as perpendicular distance between skin and pleural cavity. Chest X-ray reports from immediately prior and after chest tube removal were reviewed for interval development of PPP. Data are presented as average ± standard deviation. Ninety-one chest tubes were inserted into 81 patients. Patients who died before chest tube removal (n = 11), or those without thoracic CT scans (n = 13) were excluded. PPP occurred in 29.9 per cent of chest tube removals (20/67). When PPP was encountered, repeat chest tube was necessary in 20 per cent of cases (4/20). After univariate analysis, younger age, penetrating mechanism, and thin chest wall were found to be significant risk factors for development of PPP. Chest Abbreviated Injury Scale score was similar in both groups. Logistic regression showed only chest wall thickness to be an independent risk factor for development of PPP.

  18. Small-bore chest tubes seem to perform better than larger tubes in treatment of spontaneous pneumothorax

    DEFF Research Database (Denmark)

    Iepsen, Ulrik Winning; Ringbæk, Thomas

    2013-01-01

    The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ......The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ...

  19. Randomized clinical trial of pigtail catheter versus chest tube in injured patients with uncomplicated traumatic pneumothorax.

    Science.gov (United States)

    Kulvatunyou, N; Erickson, L; Vijayasekaran, A; Gries, L; Joseph, B; Friese, R F; O'Keeffe, T; Tang, A L; Wynne, J L; Rhee, P

    2014-01-01

    Small pigtail catheters appear to work as well as the traditional large-bore chest tubes in patients with traumatic pneumothorax, but it is not known whether the smaller pigtail catheters are associated with less tube-site pain. This study was conducted to compare tube-site pain following pigtail catheter or chest tube insertion in patients with uncomplicated traumatic pneumothorax. This prospective randomized trial compared 14-Fr pigtail catheters and 28-Fr chest tubes in patients with traumatic pneumothorax presenting to a level I trauma centre from July 2010 to February 2012. Patients who required emergency tube placement, those who refused and those who could not respond to pain assessment were excluded. Primary outcomes were tube-site pain, as assessed by a numerical rating scale, and total pain medication use. Secondary outcomes included the success rate of pneumothorax resolution and insertion-related complications. Forty patients were enrolled. Baseline characteristics of 20 patients in the pigtail catheter group were similar to those of 20 patients in the chest tube group. No patient had a flail chest or haemothorax. Pain scores related to chest wall trauma were similar in the two groups. Patients with a pigtail catheter had significantly lower mean(s.d.) tube-site pain scores than those with a chest tube, at baseline after tube insertion (3.2(0.6) versus 7.7(0.6); P pneumothorax, use of a 14-Fr pigtail catheter is associated with reduced pain at the site of insertion, with no other clinically important differences noted compared with chest tubes. NCT01537289 (http://clinicaltrials.gov). © 2013 BJS Society Ltd. Published by John Wiley & Sons Ltd.

  20. Chest tube care in critically ill patient: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Hanan Mohammed Mohammed

    2015-10-01

    Full Text Available Breathing is automatic. We don’t usually think too much about it unless we develop a problem. Lack of adequate ventilation and impairment of our respiratory system can quickly become life-threatening. There are many clinical conditions that may necessitate the use of chest tubes. When there is an accumulation of positive pressure in the chest cavity (where it should normally be negative pressure between pleurae, a patient will require chest drainage. Chest tubes may be inserted to drain body fluids or to facilitate the re-expansion of a lung. It is important for the clinician to determine the most appropriate tube size to use prior to intubation. The position of the chest tube is related to the function that the chest tube performs. When managing the care of patients who have chest tubes it is important to fully understand what to do in case problems arise. It is also important to be able to assess when the chest tube is ready to be discontinued. Nurses and other healthcare professionals who are responsible for the safe delivery of care should be knowledgeable about respiratory pathophysiology, signs of respiratory compromise, and the care and management of interventions that may be utilized to ensure adequate respiration.

  1. Clinical assessment compared with chest X-Ray after removal of chest tube to diagnose pneumothorax

    International Nuclear Information System (INIS)

    Majeed, F. A.; Noor, Q. U. H.; Mehmood, U.; Imtiaz, T.; Zafar, U.

    2017-01-01

    Objective: To evaluate clinical judgment in ruling out pneumothorax during the removal of the chest tube by auscultating the chest before removal and after the extubation of the chest tube in comparison to x ray radiological results. Study Design: Descriptive cross sectional study. Place and Duration of Study: Combined Military Hospital (CMH) Lahore Pakistan, from August 2015 to March 2016. Material and Methods: A sample size of 100 was calculated. Patients were selected via non probability purposive sampling. Children under 14 years were not included. The patients with mal-positioned chest tube, surgical site infection, air leak and the patients with more than one chest tube on one side were excluded. A proforma was made and filled by one person. Chest tubes were removed by two trained senior registrars according to a protocol devised. It was ensured that there was no air leak present before removal clinically and radiologically. Another chest x-ray was done within 24 hours of extubation to detect any pathology that might have occurred during the process. Any complication in the patient clinically was observed till the x-ray film became available. Two sets of readings were obtained. Set A included auscultation findings and set B included x ray results. Results: Out of 100 patients, 60 (60 percent) were males and 40 (40 percent) females. The ages of the patients ranged between 17-77 years. Mean age of the patient was 43.27 ± 17.05 years. In set A out of 100 (100 percent) no pneumothorax developed clinically. In set B out of 100 patients 99 (99 percent) showed no pneumothorax on chest x ray, only 1 (1 percent) showed pneumothorax which was not significant (less than 15 percent on X ray). However, the patient remained asymptomatic clinically and there was no need of reinsertion of the chest tube. Conclusion: Auscultatory findings in diagnosing a significant pneumothorax are justified. Hence, if the chest tube is removed according to the protocol, clinically by

  2. Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Nahum, E.; Ben-Ari, J.; Schonfeld, T. [Pediatric Intensive Care Unit, Schneider Children' s Medical Center of Israel, Petah Tiqva (Israel); Horev, G. [Dept. of Diagnostic Radiology, Schneider Children' s Medical Center of Israel, Petah Tiqva (Israel); Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2001-06-01

    A 3{sup 1}/{sub 2}-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

  3. Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve

    International Nuclear Information System (INIS)

    Nahum, E.; Ben-Ari, J.; Schonfeld, T.; Horev, G.

    2001-01-01

    A 3 1 / 2 -year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

  4. Volume Threshold for Chest Tube Removal: A Randomized ‎Controlled Trial

    Directory of Open Access Journals (Sweden)

    Sajad Hatami

    2009-07-01

    Full Text Available Background: Despite importance of chest tube insertion in chest trauma, there is no ‎general agreement on the level of daily volume drainage from chest tube. This study ‎was conducted to compare the effectiveness and safety of chest tube removal at the ‎levels of 150 ml/day and 2oo ml/day. Methods: Eligible patients (138 who needed replacement of chest tube (because of ‎trauma or malignancy were randomized into two groups; control (removal of chest tube ‎when drainage reached to 150 ml/day and trial (removal of chest tube at the level of ‎‎200 ml/day. All patients received standard care during hospital admission and a follow-‎up visit after 7days of discharge from hospital. Patients were then compared in terms of ‎major clinical outcomes using chi-squared and t-test. Results: From the total of 138 patients, 70 and 68 patients were randomized to control ‎‎(G150 and trial (G200 group, respectively. Baseline characteristics were comparable ‎between the two groups. Although the trial group had a shorter mean for length of ‎hospital stay (LOS (4.1 compared to 4.8, p=0.04, their differences in drainage time ‎did not reach to the level of statistical significance (p=0.1. Analysis of data showed no ‎statistically significant differences between the rate of radiological reaccumulation, ‎thoracentesis and decrease in pulmonary sounds (auscultatory, one week after ‎discharge from hospital.‎‏ ‏Conclusions: Compared to a daily volume drainage of 150 ml, removal of chest tube ‎when there is 200 ml/day is safe and will even result in a shorter hospital stay. This in ‎turn leads to a lower cost.‎

  5. Are chest radiographs routinely necessary following thoracostomy tube removal?

    International Nuclear Information System (INIS)

    Pacharn, Preeyacha; Heller, Daniel N.D.; Kammen, Bamidele F.; Bryce, Thomas J.; Bailey, Richard A.; Brasch, Robert C.; Reddy, Mohan V.

    2002-01-01

    Objective: Chest radiographs (CXRs) are routinely obtained at many institutions in all pediatric patients following thoracostomy tube removal to search for pneumothorax (PTX). To aid in evaluating the necessity of this practice, this study investigates whether clinical signs and symptoms may be a sensitive predictor of PTX in such patients. Materials and methods: Reports from CXRs obtained following chest tube removal in all pediatric patients (374 patients) who underwent cardiac surgery with chest tube placement over 1 year were reviewed. For cases with reported PTX, the PTX was quantified and chart review was performed to assess whether signs and symptoms of PTX preceded the CXR result. Results: Fifty-one of 374 children (13.6%) had a radiographically defined PTX within 6 h after thoracostomy tube removal. The PTX was large (>40%) in 2 children, moderate (20-40%) in 5 children, and small (<20%) in 44 children. Symptoms (dyspnea, tachypnea, respiratory distress) or signs (increased oxygen requirement, worsening arterial blood gas and/or hypotension) of respiratory distress were present at the time of the initial CXR in six of seven patients, who later underwent a major clinical intervention, and in one patient who did not. Major clinical interventions were performed in all patients with a large PTX, four of five patients with a moderate PTX, and one patient with a small PTX that later enlarged. Conclusions: Clinical signs and symptoms identified nearly all patients with significant pneumothoraces. Future prospective investigations may examine reserving chest radiography following chest tube removal for select groups, such as symptomatic patients or those with tenuous cardiovascular status. (orig.)

  6. Chest Tube Management after Surgery for Pneumothorax.

    Science.gov (United States)

    Pompili, Cecilia; Salati, Michele; Brunelli, Alessandro

    2017-02-01

    There is scant evidence on the management of chest tubes after surgery for pneumothorax. Most of the current knowledge is extrapolated from studies performed on subjects with lung cancer. This article reviews the existing literature with particular focus on the effect of suction and no suction on the duration of air leak after lung resection and surgery for pneumothorax. Moreover, the role of regulated suction, which seems to provide some benefit in reducing pneumothorax recurrence after bullectomy and pleurodesis, is discussed. Finally, a personal view on the management of chest tubes after surgery for pneumothorax is provided. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. The impact of a chest tube management protocol on the outcome of trauma patients with tube thoracostomy.

    Science.gov (United States)

    de Abreu, Emanuelle Maria Sávio; Machado, Carla Jorge; Pastore Neto, Mario; de Rezende Neto, João Baptista; Sanches, Marcelo Dias

    2015-01-01

    to investigate the effect of standardized interventions in the management of tube thoracostomy patients and to assess the independent effect of each intervention. A chest tube management protocol was assessed in a retrospective cohort study. The tube thoracostomy protocol (TTP) was implemented in August 2012, and consisted of: antimicrobial prophylaxis, chest tube insertion in the operating room (OR), admission post chest tube thoracostomy (CTT) in a hospital floor separate from the emergency department (ED), and daily respiratory therapy (RT) sessions post-CTT. The inclusion criteria were, hemodynamic stability, patients between the ages of 15 and 59 years, and injury severity score (ISS) chest wall, lung, and pleura. During the study period 92 patients were managed according to the standardized protocol. The outcomes of those patients were compared to 99 patients treated before the TTP. Multivariate logistic regression analysis was performed to assess the independent effect of each variable of the protocol on selected outcomes. Demographics, injury severity, and trauma mechanisms were similar among the groups. As expected, protocol compliance increased after the implementation of the TTP. There was a significant reduction (pchest tube days. Respiratory therapy was independently linked to significant reduction (pchest tube insertion was associated with significant (ptrauma patients.

  8. Conservative use of chest-tube insertion in children with pleural effusion.

    Science.gov (United States)

    Epaud, R; Aubertin, G; Larroquet, M; Pointe, H Ducou-le; Helardot, P; Clement, A; Fauroux, B

    2006-04-01

    The aim of this work was to evaluate the effect of a more conservative use of chest-tube insertion on the short-term and long-term outcome of pleural infection. Sixty-five patients with pleural infection, aged 1 month to 16 years were each treated according to one of the two protocols: classical management with chest-tube insertion (classical group, n = 33), or conservative use of chest-tube insertion (conservative group, n = 32), with drainage indicated only in the case of voluminous pleural effusion defined by a mediastinal shift and respiratory distress and/or an uncontrolled septic situation. The two groups were comparable with regard to age, baseline C-reactive protein (CRP) value and white blood cell counts, pleural thickness, identified bacteria, and antibiotic treatment. Chest-tube insertion was performed in 17 patients (52%) of the classical group compared to eight patients (25%) of the conservative group (P = 0.03). Duration of temperature above 39 degrees C was shorter in the conservative group (10 +/- 1 vs. 14 +/- 1 days, P = 0.01), as was the normalization of CRP (13 +/- 1 vs. 17 +/- 1 days, P = 0.03). Duration of hospitalization and intravenous (IV) antibiotherapy as well as the delay of chest-radiograph normalization was not significantly different between the two groups. A more conservative use of chest-tube insertion did not change short- and long-term outcome of the pleural infection in children. Drainage could be restricted to the most severely affected patients with pleural empyema causing a mediastinal shift and respiratory distress and/or presenting with an uncontrolled septic situation.

  9. A novel method for improving chest tube insertion skills among medical interns

    Science.gov (United States)

    Tatli, Ozgur; Turkmen, Suha; Imamoglu, Melih; Karaca, Yunus; Cicek, Mustafa; Yadigaroglu, Metin; Bayrak, Selen T.; Asik, Olgun; Topbas, Murat; Turedi, Suleyman

    2017-01-01

    Objectives: To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42). Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand. PMID:28917064

  10. Tube thorocostomy: management and outcome in patients with penetrating chest trauma.

    Science.gov (United States)

    Muslim, Muhammad; Bilal, Amer; Salim, Muhammad; Khan, Muhammad Abid; Baseer, Abdul; Ahmed, Manzoor

    2008-01-01

    Penetrating chest trauma is common in this part of the world due to present situation in tribal areas. The first line of management after resuscitation in these patients is tube thoracostomy combined with analgesia and incentive spirometry. After tube thoracostomy following surgery or trauma there are two schools of thought one favours application of continuous low pressure suction to the chest tubes beyond the water seal while other are against it. We studied the application of continuous low pressure suction in patients with penetrating chest trauma. This Randomized clinical controlled trial was conducted in the department of thoracic surgery Post Graduate Medical Institute Lady Reading Hospital Peshawar from July 2007 to March 2008. The objectives of study were to evaluate the effectiveness of continuous low pressure suction in patients with penetrating chest trauma for evacuation of blood, expansion of lung and prevention of clotted Haemothorax. One hundred patients who underwent tube thoracostomy after penetrating chest trauma from fire arm injury or stab wounds were included in the study. Patients with multiple trauma, blunt chest trauma and those intubated for any pulmonary or pleural disease were excluded from the study. After resuscitation, detailed examination and necessary investigations patients were randomized to two groups. Group I included patients who had continuous low pressure suction applied to their chest drains. Group II included those patients whose chest drains were placed on water seal only. Lung expansion development of pneumothorax or clotted Haemothorax, time to removal of chest drain and hospital stay was noted in each group. There were fifty patients in each group. The two groups were not significantly different from each other regarding age, sex, pre-intubation haemoglobin and pre intubation nutritional status. Full lung expansion was achieved in forty six (92%) patients in group I and thirty seven (74%) in group II. Partial lung

  11. Intrapulmonary pseudo-malposition of chest tubes on computed tomography (CT)

    International Nuclear Information System (INIS)

    Flueckiger, F.; Kullnig, P.; Juettner-Smolle, F.; Melzer, G.; Graz Univ.

    1991-01-01

    The diagnosis of an intrapulmonary malposition of chest tubes on CT may be problematic. We report about 13 chest tubes which were suspected on CT to be in an intrapulmonary malposition. In all cases as well as clinical and radiological follow up ruled out such a malposition. The use of a stiff tube and the presence of a soft lung parenchyma obviously led to a sinking of the tube into a 'channel'. Whereas after removal of the tube in case of such a pseudo-malposition solely a transitory local fluid collection and later a tender scar is seen, real intrapumonary malposition leads to parenchymal injury and concomitant complications. The diagnosis of intrapulmonary malposition should be doubted, if the drain is positioned within the pleural space after having crossed the lung parenchyma in a supposed intrapulmonary rout. The CT criterias of this pseudo-malposition are presented and discussed. (orig.) [de

  12. A pilot study of chest tube versus pigtail catheter drainage of acute hemothorax in swine.

    Science.gov (United States)

    Russo, Rachel M; Zakaluzny, Scott A; Neff, Lucas P; Grayson, J Kevin; Hight, Rachel A; Galante, Joseph M; Shatz, David V

    2015-12-01

    Evacuation of traumatic hemothorax (HTx) is typically accomplished with large-bore (28-40 Fr) chest tubes, often resulting in patient discomfort. Management of HTx with smaller (14 Fr) pigtail catheters has not been widely adopted because of concerns about tube occlusion and blood evacuation rates. We compared pigtail catheters with chest tubes for the drainage of acute HTx in a swine model. Six Yorkshire cross-bred swine (44-54 kg) were anesthetized, instrumented, and mechanically ventilated. A 32 Fr chest tube was placed in one randomly assigned hemithorax; a 14 Fr pigtail catheter was placed in the other. Each was connected to a chest drainage system at -20 cm H2O suction and clamped. Over 15 minutes, 1,500 mL of arterial blood was withdrawn via femoral artery catheters. Seven hundred fifty milliliters of the withdrawn blood was instilled into each pleural space, and fluid resuscitation with colloid was initiated. The chest drains were then unclamped. Output from each drain was measured every minute for 5 minutes and then every 5 minutes for 40 minutes. The swine were euthanized, and thoracotomies were performed to quantify the volume of blood remaining in each pleural space and to examine the position of each tube. Blood drainage was more rapid from the chest tube during the first 3 minutes compared with the pigtail catheter (348 ± 109 mL/min vs. 176 ± 53 mL/min), but this difference was not statistically significant (p = 0.19). Thereafter, the rates of drainage between the two tubes were not substantially different. The chest tube drained a higher total percentage of the blood from the chest (87.3% vs. 70.3%), but this difference did not reach statistical significance (p = 0.21). We found no statistically significant difference in the volume of blood drained by a 14 Fr pigtail catheter compared with a 32 Fr chest tube.

  13. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    Science.gov (United States)

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  14. Evaluation of performance of two different chest tubes with either a sharp or a blunt tip for thoracostomy in 100 human cadavers

    Directory of Open Access Journals (Sweden)

    Ortner Clemens M

    2012-02-01

    Full Text Available Abstract Background Emergent placement of a chest tube is a potentially life-saving procedure, but rate of misplacement and organ injury is up to 30%. In principle, chest tube insertion can be performed by using Trocar or Non-trocar techniques. If using trocar technique, two different chest tubes (equipped with sharp or blunt tip are currently commercially available. This study was performed to detect any difference with respect to time until tube insertion, to success and to misplacement rate. Methods Twenty emergency physicians performed five tube thoracostomies using both blunt and sharp tipped tube kits in 100 fresh human cadavers (100 thoracostomies with each kit. Time until tube insertion served as primary outcome. Complications and success rate were examined by pathological dissection and served as further outcomes parameters. Results Difference in mean time until tube insertion (63s vs. 59s was statistically not significant. In both groups, time for insertion decreased from the 1st to the 5th attempt and showed dependency on the cadaver's BMI and on the individual physician. Success rate differed between both groups (92% using blunt vs. 86% using sharp tipped kits and injuries and misplacements occurred significantly more frequently using chest tubes with sharp tips (p = 0.04. Conclusion Data suggest that chest drain insertion with trocars is associated with a 6-14% operator-related complication rate. No difference in average time could be found. However, misplacements and organ injuries occurred more frequently using sharp tips. Consequently, if using a trocar technique, the use of blunt tipped kits is recommended.

  15. Comparison of pigtail catheter with chest tube for drainage of parapneumonic effusion in children.

    Science.gov (United States)

    Lin, Chien-Heng; Lin, Wei-Ching; Chang, Jeng-Sheng

    2011-12-01

    The use of thoracostomy tube for drainage of parapneumonic effusion is an important therapeutic measure. In this study, we compared the effectiveness and complications between chest tube and pigtail catheter thoracostomy for drainage of parapneumonic pleural effusion in children. We retrospectively reviewed the medical records of children with parapneumonic effusion during the period of July 2001 through December 2003. Patients who received thoracostomy with either chest tube or pigtail catheter were enrolled into this study. Medical records, such as age, sex, clinical presentation, subsequent therapies, hospital stay, laboratory data, and complications, were collected and compared between these two methods of intervention. A total of 32 patients (17 boys and 15 girls; age range, 2-17 years; mean age, 14 years) were enrolled into the study. Twenty patients were treated with traditional chest tubes, whereas 12 patients were treated with pigtail catheters. In the chest tube group, drainage failure occurred in one patient and pneumothorax occurred in two patients. In the pigtail catheter group, drainage failure occurred in two patients, but no case was complicated with pneumothorax. There were no significant differences in either drainage days or hospitalization days between the chest tube group and pigtail catheter group (6.0 ± 2.6 vs. 5.9 ± 3.8, p=0.66; 12.5 ± 5.6 vs. 17.3 ± 8.5, p=0.13). The effectiveness and complications of the pigtail catheter were comparable to those of the chest tubes. Copyright © 2011. Published by Elsevier B.V.

  16. Monitoring the monitors: tubes and lines on chest radiographs

    International Nuclear Information System (INIS)

    Wunderbaldinger, P. . patrick.wunderbaldinger@univie.ac.at

    2001-01-01

    Chest radiography is essential to evaluate the placement and position of tubes and lines in patients treated in intensive care units, such as central venous and arterial catheters, endotracheal and nasogastric tubes, thorax drains, cardiac pacemakers and defibrillators. Radiologic findings with respect to normal positioning, wrong positioning, and complications are described and illustrated. (author)

  17. Chest tube drainage of pleural effusions--an audit of current practice and complications at Hutt Hospital.

    Science.gov (United States)

    Epstein, Erica; Jayathissa, Sisira; Dee, Stephen

    2012-05-11

    The aims of the study were to review small-bore chest tube insertion practices for drainage of pleural fluid at Hutt Valley District Health Board (HVDHB), to assess complications, and compare the findings with international data. Retrospective analysis of clinical records was completed on all chest tube insertions for drainage of pleural fluid at HVDHB from December 2008 to November 2009. Descriptive statistics were used to present demographics and tube-associated complications. Comparison was made to available similar international data. Small-bore tubes comprised 59/65 (91%) chest tube insertions and 23/25 (92%) complications. Available comparative data was limited. Ultrasound was used in 36% of insertions. Nearly half of chest drains placed for empyema required subsequent cardiothoracic surgical intervention. Chest drain complication rates at HVDHB were comparable to those seen internationally. Referral rates to cardiothoracic surgery for empyema were within described ranges. The importance of procedural training for junior medical staff, optimising safety of drain insertions with ultrasound guidance, and clear clinical governance for chest tube insertions are important in minimising harm from this procedure. Specialist societies need to take a leadership in providing guidance on chest drain insertions to secondary and tertiary hospitals in Australia and New Zealand.

  18. What are the Advantages? A Prospective Analysis of 16 versus 28 French Chest Tube Sizes in Video-assisted Thoracoscopic Surgery Lobectomy of Lung Cancer

    Directory of Open Access Journals (Sweden)

    Mei YANG

    2015-08-01

    Full Text Available Background and objective Post-operation management of minimally invasive thoracic surgery is similar to that of open surgery, especially on the drainage tube of the chest. The aim of this study is to compare the advantages of using 16 F versus 28 F chest tubes in video-assisted thoracoscopic surgery (VATS lobectomy of lung cancer. Methods Data from 163 patients (February-May 2014 who underwent VATS lobectomy of lung cancer with insertion of one chest drain (16 F or 28 F were analyzed. The following post-operative data were evaluated: primary healing of tube incision, CXR abnormalities (pneumothorax, fluid, atelectasis, subcutaneous emphysema, and hematoma, drainage time, new drain insertion, and wound healing at the site of insertion. Results A total of 75 patients received 28 F chest tubes, and 88 patients received 16 F chest tubes. Both groups were similar in age, gender, comorbidities, and pathological evaluation of resection specimens. After adjustment, no statistically significant difference was found between the two groups in relation to tube-related complications including residual pneumothoraces (4.00% vs 4.44%; P=0.999, subcutaneous emphysema (8.00% vs 6.67%; P=0.789, retained hemothorax (0 vs 41%, P=0.253, and drainage time [(28.4±16.12 h vs (22.1±11.8 h; P=0.120] The average total drainage volume and rrhythmia rates of the 16 F group [(365±106 mL, 14.67%] was less than that of the 28 F group [(665±217 mL, 4.5%; P=0.030, P=0.047]. The rates of primary healing at the site of insertion in the 16 F group (95.45% was higher than that in the 28 F group (77.73%, P=0.039. A significant difference was found on the post-operative length of stay of the two groups [(4.23±0.05 d vs (4.57±0.16 d, P=0.078]. Conclusion The use of 16 F chest tube for VATS lobectomy of patients with lung cancer did not affect the clinically relevant outcomes tested. However, 16 F chest tube facilitated faster wound healing at the site of insertion.

  19. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  20. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  1. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial.

    Science.gov (United States)

    Haubruck, Patrick; Nickel, Felix; Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-05-21

    individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I 50 =7.0] points; control group: 30.5 [I 50 =8.0] points; Pgames are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg). ©Patrick Haubruck, Felix Nickel, Julian Ober, Tilman Walker, Christian Bergdolt, Mirco Friedrich, Beat Peter Müller-Stich, Franziska Forchheim, Christian Fischer, Gerhard Schmidmaier, Michael C Tanner. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.05.2018.

  2. Evaluation of App-Based Serious Gaming as a Training Method in Teaching Chest Tube Insertion to Medical Students: Randomized Controlled Trial

    Science.gov (United States)

    Ober, Julian; Walker, Tilman; Bergdolt, Christian; Friedrich, Mirco; Müller-Stich, Beat Peter; Forchheim, Franziska; Fischer, Christian; Schmidmaier, Gerhard; Tanner, Michael C

    2018-01-01

    , trainees gave information about their individual training level, as well as previous experiences, gender, and hobbies. Primary end point was operative performance during chest tube insertion by direct observance. Results A total of 183 students enrolled, 116 students participated (63.4%), and 21 were excluded because of previous experiences in chest tube insertion. Students were randomized to the intervention group (49/95, 52%) and control group (46/95, 48%). The intervention group performed significantly better than the control group (Intervention group: 38.0 [I50=7.0] points; control group: 30.5 [I50=8.0] points; P<.001). The intervention group showed significantly improved economy of time and motion (P=.004), needed significantly less help (P<.001), and was more confident in handling of instruments (P<.001) than the control group. Conclusions The results from this study show that serious games are a valid and effective tool in education of operative performance in chest tube insertion. We believe that serious games should be implemented in the surgical curriculum, as well as residency programs, in addition to traditional learning methods. Trial Registration German Clinical Trials Register (DRKS) DRKS00009994; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00009994 (Archived by Webcite at http://www.webcitation.org/6ytWF1CWg) PMID:29784634

  3. Inadvertent chest tube insertion in congenital cystic adenomatoid malformation and congenital lobar emphysema-highlighting an important problem

    International Nuclear Information System (INIS)

    Prabhu, Shailesh M; Choudhury, Subhasis Roy; Solanki, Ravi S; Shetty, Gurucharan S; Agarwala, Surenderkumar

    2013-01-01

    Chest tube insertion in congenital cystic lung lesions is an important problem in children with acute respiratory distress having a cystic lucent lesion on chest radiograph. To evaluate the imaging findings and complications in cases of congenital cystic lung lesions with chest tube insertion and suggest the role of appropriate imaging for management of these patients. Chest radiographs and CT scans of children with congenital cystic lung lesions who had inadvertent chest tube insertion preoperatively were retrospectively reviewed for imaging appearances and complications. Fifteen patients comprising 10 cases of congenital cystic adenomatoid malformation (CCAM) and 5 cases of congenital lobar emphysema (CLE) were included. Majority of the cases were infants. CCAM was misdiagnosed as complicated pneumatocele (n = 5) and pneumothorax (n = 5), while CLE was misdiagnosed as tension pneumothorax (n = 5) on the chest radiograph findings. Final diagnosis was made on CT and operative findings with histopathology. Complications noted were pneumothorax, hydropneumothorax, and infection in cases of CCAM, and change in imaging appearance and pneumothorax in cases of CLE. Chest tube insertion in congenital cystic lesions increases the rate of associated complications. Chest CT has a definite role in early diagnosis and deciding appropriate management in these cases

  4. Management of chest tubes after pulmonary resection: a systematic review and meta-analysis.

    Science.gov (United States)

    Coughlin, Shaun M; Emmerton-Coughlin, Heather M A; Malthaner, Richard

    2012-08-01

    We performed a systematic review and meta-analysis to determine the effect of suction with water seal, compared with water seal alone, applied to intra pleural chest tubes on the duration of air leaks in patients undergoing pulmonary surgery. We searched MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials to find randomized controlled trials (RCTs) comparing the effect of the 2 methods on the duration of air leaks. Trials were systematically assessed for eligibility and validity. Data were extracted in duplicate and pooled across studies using a random-effects model. The search yielded 7 RCTs that met the eligibility criteria. No difference was identified between the 2 methods in duration of air leak (weighted mean difference [WMD] 1.15 days, favours water seal; 95% confidence interval [CI] -0.64 to 2.94), time to discharge (WMD 2.19 d, favours water seal; 95% CI -0.63 to 5.01), duration of chest tubes (WMD 0.96 d, favours water seal; 95% CI -0.12 to 2.05) or incidence of prolonged air leaks (absolute risk reduction [ARR] 0.04, favours water seal; 95% CI -0.01 to 0.09). Water seal was associated with a significantly increased incidence of postoperative pneumothorax (ARR -0.14, 95% CI -0.21 to -0.07). No differences were identified in terms of duration of air leak, incidence of prolonged air leak, duration of chest tubes and duration of hospital stay when chest tubes were placed to suction rather than water seal. Chest tube suction appears to be superior to water seal in reducing the incidence of pneumothorax; however, the clinical significance of this finding is unclear.

  5. Prehospital chest tube thoracostomy: effective treatment or additional trauma?

    NARCIS (Netherlands)

    Spanjersberg, W.R.; Bergs, B.; Krijen, P.; Schipper, I.; Ringburg, A.; Steyerberg, E.W.; Edwards, M.J.R.; Schipper, I.B.; Vugt, A.B. van

    2005-01-01

    BACKGROUND: The use of prehospital chest tube thoracostomy (TT) remains controversial because of presumed increased complication risks. This study analyzed infectious complication rates for physician-performed prehospital and emergency department (ED) TT. METHODS: Over a 40-month period, all

  6. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage

    Science.gov (United States)

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Objective Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. Description We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. Methods After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at −20 cm H2O for 30 min. Results When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, Pdrain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. Conclusion The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications. PMID:25478289

  7. Novel Split Chest Tube Improves Post-Surgical Thoracic Drainage.

    Science.gov (United States)

    Olivencia-Yurvati, Albert H; Cherry, Brandon H; Gurji, Hunaid A; White, Daniel W; Newton, J Tyler; Scott, Gary F; Hoxha, Besim; Gourlay, Terence; Mallet, Robert T

    2014-01-01

    Conventional, separate mediastinal and pleural tubes are often inefficient at draining thoracic effusions. We developed a Y-shaped chest tube with split ends that divide within the thoracic cavity, permitting separate intrathoracic placement and requiring a single exit port. In this study, thoracic drainage by the split drain vs. that of separate drains was tested. After sternotomy, pericardiotomy, and left pleurotomy, pigs were fitted with separate chest drains (n=10) or a split tube prototype (n=9) with internal openings positioned in the mediastinum and in the costo-diaphragmatic recess. Separate series of experiments were conducted to test drainage of D5W or 0.58 M sucrose, an aqueous solution with viscosity approximating that of plasma. One litre of fluid was infused into the thorax, and suction was applied at -20 cm H2O for 30 min. When D5W was infused, the split drain left a residual volume of 53 ± 99 ml (mean value ± SD) vs. 148 ± 120 for the separate drain (P=0.007), representing a drainage efficiency (i.e. drained vol/[drained + residual vol]) of 95 ± 10% vs. 86 ± 12% for the separate drains (P = 0.011). In the second series, the split drain evacuated more 0.58 M sucrose in the first minute (967 ± 129 ml) than the separate drains (680 ± 192 ml, Pdrain evacuated a similar volume of sucrose vs. the conventional drain (1089 ± 72 vs. 1056 ± 78 ml; P = 0.5). Residual volume tended to be lower (25 ± 10 vs. 62 ± 72 ml; P = 0.128) and drainage efficiency tended to be higher (98 ± 1 vs. 95 ± 6%; P = 0.111) with the split drain vs. conventional separate drains. The split chest tube drained the thoracic cavity at least as effectively as conventional separate tubes. This new device could potentially alleviate postoperative complications.

  8. A prehospital use of ITClamp for haemostatic control and fixation of a chest tube

    DEFF Research Database (Denmark)

    Barnung, S; Steinmetz, J

    2014-01-01

    We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube.......We here present three cases in which a new device, the ITClamp Hemorrhage Control System (Innovative Trauma Care, Inc., Edmonton, Canada), was used for bleeding control and for securing a chest tube....

  9. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial.

    Science.gov (United States)

    Mirmohammad-Sadeghi, Mohsen; Pourazari, Pejman; Akbari, Mojtaba

    2017-01-01

    Chest tubes are used in every case of coronary artery bypass grafting (CABG) to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group ( P = 0.001), but the trend of pain score between groups was not significantly different ( P = 0.097). The frequency of tamponade and atrial fibrillation (AF) were significantly lower in Jackson-Pratt drain group ( P drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  10. A novel method for improving chest tube insertion skills among medical interns. Using biomaterial-covered mannequin

    Directory of Open Access Journals (Sweden)

    Ozgur Tatli

    2017-10-01

    Full Text Available Objectives: To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42. Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand.

  11. A novel method for improving chest tube insertion skills among medical interns. Using biomaterial-covered mannequin.

    Science.gov (United States)

    Tatli, Ozgur; Turkmen, Suha; Imamoglu, Melih; Karaca, Yunus; Cicek, Mustafa; Yadigaroglu, Metin; Bayrak, Selen T; Asik, Olgun; Topbas, Murat; Turedi, Suleyman

    2017-10-01

    To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42). Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand.

  12. Comparison consequences of Jackson-Pratt drain versus chest tube after coronary artery bypass grafting: A randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Mohsen Mirmohammad-Sadeghi

    2017-01-01

    Full Text Available Background: Chest tubes are used in every case of coronary artery bypass grafting (CABG to evacuate shed blood from around the heart and lungs. This study was designed to assess the effective of Jackson-Pratt drain in compare with conventional chest drains after CABG. Materials and Methods: This was a randomized controlled trial that conducted on 218 patients in Chamran hospital from February to December 2016. Eligible patients were randomized in a 1:1 ratio. Jackson-Pratt drain group had 109 patients who received a chest tube insertion in the pleural space of the left lung and a Jackson-Pratt drain in mediastinum, and Chest tube drainage group had 109 patients who received double chest tube insertion in the pleural space of the left lung and the mediastinum. Results: The incidence of pleural effusions in Jackson-Pratt drain group and chest tube group were not statistically different. The pain score at 2-h in Drain group was significantly higher than chest tube group (P = 0.001, but the trend of pain score between groups was not significantly different (P = 0.097. The frequency of tamponade and atrial fibrillation (AF were significantly lower in Jackson-Pratt drain group (P < 0.05. Conclusion: The Jackson-Pratt drain is equally effective for preventing cardiac tamponade, pleural effusions, and pain intensity in patients after CABG when compared with conventional chest tubes, but was significantly superior regarding efficacy to hospital and Intensive Care Unit length of stay and the incidence of AF.

  13. Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential

    Energy Technology Data Exchange (ETDEWEB)

    Gnannt, Ralph; Winklehner, Anna; Frauenfelder, Thomas; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Eberli, Daniel [University Hospital Zurich, Clinic for Urology, Zurich (Switzerland); Knuth, Alexander [University Hospital Zurich, Clinic for Oncology, Zurich (Switzerland)

    2012-09-15

    To evaluate prospectively, in patients with testicular cancer, the radiation dose-saving potential and image quality of contrast-enhanced chest and abdominal CT with automated tube potential selection. Forty consecutive patients with testicular cancer underwent contrast-enhanced arterio-venous chest and portal-venous abdominal CT with automated tube potential selection (protocol B; tube potential 80-140 kVp), which is based on the attenuation of the CT topogram. All had a first CT at 120 kVp (protocol A) using the same 64-section CT machine and similar settings. Image quality was assessed; dose information (CTDI{sub vol}) was noted. Image noise and attenuation in the liver and spleen were significantly higher for protocol B (P < 0.05 each), whereas attenuation in the deltoid and erector spinae muscles was similar. In protocol B, tube potential was reduced to 100 kVp in 18 chest and 33 abdominal examinations, and to 80 kVp in 5 abdominal CT examinations; it increased to 140 kVp in one patient. Image quality of examinations using both CT protocols was rated as diagnostic. CTDI{sub vol} was significantly lower for protocol B compared to protocol A (reduction by 12%, P < 0.01). In patients with testicular cancer, radiation dose of chest and abdominal CT can be reduced with automated tube potential selection, while image quality is preserved. (orig.)

  14. Effect of Body Mass Index on Postoperative Transfusions and 24-Hour Chest-Tube Output

    Science.gov (United States)

    Nolan, Heather R.; Ramaiah, Chandrashekhar

    2011-01-01

    An increasing obese population in the United States focuses attention on the effect of obesity on surgical outcomes. Our objective was to see if obesity, determined by body mass index (BMI), contributed to bleeding in coronary artery bypass graft (CABG) surgery as measured by intraoperative and postoperative packed red blood cell transfusion frequency and amount and 24-hour chest-tube output. A retrospective chart review examined 150 subjects undergoing single-surgeon off-pump or on-pump CABG surgery between September 2006 and April 2009. BMI groups included normal-weight (BMI trend based on BMI group (p = 0.054). The percentage of subjects receiving transfusions in the combined intraoperative or 72-hour postoperative period showed a decreasing linear trend based on BMI group (p = 0.054). The transfusion amount during the 72-hour postoperative period varied significantly between BMI groups (p = 0.021), and the test for a linear decrease across groups was significant (p = 0.020). Twenty-four hour chest-tube output showed variation across all three BMI categories (p = 0.018) with chest-tube output decreasing with increasing obesity in a linear fashion (p = 0.006). Transfusion rate and amount indicate total blood loss is decreased in the obese, and chest-tube output findings give a direct measurable indicator of blood loss from the surgical site indicating increasing BMI is linearly correlated with decreasing postoperative bleeding. PMID:22654469

  15. The combined effects of cold therapy and music therapy on pain following chest tube removal among patients with cardiac bypass surgery.

    Science.gov (United States)

    Yarahmadi, Sajad; Mohammadi, Nooredin; Ardalan, Arash; Najafizadeh, Hassan; Gholami, Mohammad

    2018-05-01

    Chest tube removal is an extremely painful procedure and patients may not respond well to palliative therapies. This study aimed to examine the effect of cold and music therapy individually, as well as a combination of these interventions on reducing pain following chest tube removal. A factorial randomized-controlled clinical trial was performed on 180 patients who underwent cardiac surgery. Patients were randomized into four groups of 45. Group A used ice packs for 20 minutes prior to chest tube removal. Group B was assigned to listen to music for a total length of 30 minutes which started 15 minutes prior to chest tube removal. Group C received a combination of both interventions; and Group D received no interventions. Pain intensity was measured in each group every 15 minutes for a total of 3 readings. Analysis of variance, Tukey and Bonferroni post hoc tests, as well as repeated measures ANOVA were employed for data analysis. Cold therapy and combined method intervention effectively reduced the pain caused by chest tube removal (P < 0.001). Additionally, there were no statistically significant difference in pain intensity scores between groups at 15 minutes following chest tube removal (P = 0.07). Cold and music therapy can be used by nursing staff in clinical practice as a combined approach to provide effective pain control following chest tube removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. The Outcome of Thoracentesis versus Chest Tube Placement for Hepatic Hydrothorax in Patients with Cirrhosis: A Nationwide Analysis of the National Inpatient Sample

    Directory of Open Access Journals (Sweden)

    Ali Ridha

    2017-01-01

    Full Text Available There are only a few studies with a small sample size of patients that have compared the risks of using chest tubes versus thoracentesis in hepatic hydrothorax. It has been shown that many complications may arise secondary to chest tube placement and is associated with increased morbidity and mortality. In this retrospective study, patients with cirrhosis were identified from the 2009 National Inpatient Sample by using ICD-9 codes; we evaluated the risk of chest tube versus thoracentesis in a largest population with hepatic hydrothorax to date to measure the mortality and the length of stay. A total of 140,573 patients with liver cirrhosis were identified. Of this, 1981 patients had a hepatic hydrothorax and ended up with either thoracentesis (1776 or chest tube (205. The mortality in those who received a chest tube was two times higher than that in thoracentesis group with a P value of ≤0.001 (CI 1.43–312. In addition, the length of hospital stay of the chest tube group was longer than that of the thoracentesis subset (7.2 days versus 3.8 days, resp.. We concluded that chest tube placement has two times higher mortality rate and longer hospital length of stay when compared to patients who underwent thoracentesis.

  17. Intra-operative removal of chest tube in video-assisted thoracoscopic procedures

    Directory of Open Access Journals (Sweden)

    Moustafa M. El-Badry

    2017-12-01

    Conclusions: Intra-operative removal of chest tube during VATS procedures was a safe technique in well selected patients with an intra-operative successful air-leak test with radiological and clinical follow-up. This technique provided lesser post-operative pain with shorter hospital stay.

  18. Effective high voltage at X-ray tube in hard X-ray chest imaging

    International Nuclear Information System (INIS)

    Klein, J.

    1987-01-01

    The FRG standard TGL 36 661 (March 1980) for synoptical chest pictures of large size in adults specifies the 120 kV voltage at the X-ray tube together with maximal, 100% use of the capacity of the tube (hard picture, short exposure time). By means of circular recording and by measuring the high voltage at the X-ray tube it was quantitatively shown that the effective voltage during exposure is (according to the exposure time and the attenuation phase of the generator) always lower than the set-up voltage of 120 kV. This phenomenon is the more marked the shorter the actual exposure time in comparison with the attenuation phase of the generator. The typical characteristic of a hard X-ray chest picture is thus not given only by the setting-up of voltage. The impact of the reduction in voltage is thus quantitatively shown also from the aspect of the radiation burden for the patient. (author). 7 figs., 8 refs

  19. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  20. Ward-based, nurse-led, outpatient chest tube management: analysis of impact, cost-effectiveness and patient safety.

    Science.gov (United States)

    Tcherveniakov, Peter; De Siqueira, Jonathan; Milton, Richard; Papagiannopoulos, Kostas

    2012-06-01

    Prolonged drainage and air leaks are recognized complications of elective and acute thoracic surgery and carry significant burden on inpatient stay and outpatient resources. Since 2007, we have run a ward-based, nurse-led clinic for patients discharged with a chest drain in situ. The aim of this study is to assess its cost-effectiveness and safety. We present a retrospective review of the activity of the clinic for a period of 12 months (November 2009-10). An analysis of the gathered data is performed, focusing specifically on the duration of chest tube indwelling, the indications, complications and cost efficiency. The nurse-led clinic was housed in the thoracic ward with no additional fixed costs. Seventy-four patients were reviewed (53 males, 21 females, mean age of 59) and subsequently discharged from the clinic in this time period, accounting for 149 care episodes. Thirty-three (45%) of the patients underwent a video-assisted thoracoscopic surgery procedure, 35 (47%) of them a thoracotomy and 7 (9%) had a bedside chest tube insertion. Following hospital discharge, the chest tubes were removed after a median of 14 days (range 1-82 days). Fifty-eight percent of the patients were reviewed because of a prolonged air leak, 26% for persistent fluid drainage and 16% due to prolonged drainage following evacuation of empyemas. For the care episodes analysed, we estimate that the clinic has generated an income of €24,899 for the department. Hourly staffing costs for the service are significantly lower compared with those of the traditional outpatient clinic: €15 vs. €114. Our results show that a dedicated chest tube monitoring clinic is a safe and efficient alternative to formal outpatient clinic review. It can lead to shorter hospital stays and is cost effective.

  1. Reduce chest pain using modified silicone fluted drain tube for chest drainage after video-assisted thoracic surgery (VATS) lung resection.

    Science.gov (United States)

    Li, Xin; Hu, Bin; Miao, Jinbai; Li, Hui

    2016-02-01

    The aim of this study was to assess the feasibility, efficacy and safety of a modified silicone fluted drain tube after video-assisted thoracic surgery (VATS) lung resection. The prospective randomized study included 50 patients who underwent VATS lung resection between March 2015 and June 2015. Eligible patients were randomized into two groups: experimental group (using the silicone fluted drain tubes for chest drainage) and control group (using standard drain tubes for chest drainage). The volume and characteristics of drainage, postoperative (PO) pain scores and hospital stay were recorded. All patients received standard care during hospital admission. In accordance with the exit criteria, three patients were excluded from study. The remaining 47 patients included in the final analysis were divided into two groups: experiment group (N=24) and control group (N=23). There was no significant difference between the two groups in terms of age, sex, height, weight, clinical diagnosis and type of surgical procedure. There was a trend toward less PO pain in experimental group on postoperative day (POD) 1, with a statistically significant difference. Patients in experimental group had a reduced occurrence of fever [temperature (T) >37.4 °C] compared to the control group. The silicone fluted drain tube is feasible and safe and may relieve patient PO pain and reduce occurrence of fever without the added risk of PO complications.

  2. Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation.

    Science.gov (United States)

    Saltybaeva, Natalia; Krauss, Andreas; Alkadhi, Hatem

    2017-03-01

    Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterior (PA) projections. Dose distributions were obtained by means of Monte Carlo simulations based on acquired CT data. For Monte Carlo simulations of localizer radiography, the tube position was fixed at 0° and 180°; for chest CT, a spiral trajectory with TCM was used. The effect of tube start angles on dose distribution was investigated with Monte Carlo simulations by using TCM curves with fixed start angles (0°, 90°, and 180°). Total doses for lungs, heart, and breast were calculated as the sum of the dose from localizer radiography and CT. Image noise was defined as the standard deviation of attenuation measured in 14 circular regions of interest. The Wilcoxon signed rank test, paired t test, and Friedman analysis of variance were conducted to evaluate differences in noise, TCM curves, and organ doses, respectively. Results Organ doses from localizer radiography were lower when using a PA instead of an AP projection (P = .005). The use of a PA projection resulted in higher TCM values for chest CT (P chest CT. © RSNA, 2016 Online supplemental material is available for this article.

  3. Influence of timing of chest tube removal on early outcome of patients underwent lung resection

    Directory of Open Access Journals (Sweden)

    Ahmed Labib Dokhan

    2016-05-01

    Conclusion: Early removal of chest tube may have beneficial effect on control of post-thoracotomy pain, improvement of pulmonary functions and decreasing the risk of complications after lung resection.

  4. Non-operative management of right side thoracoabdominal penetrating injuries--the value of testing chest tube effluent for bile.

    Science.gov (United States)

    De Rezende Neto, João Baptista; Guimarães, Tiago Nunes; Madureira, João Lopo; Drumond, Domingos André Fernandes; Leal, Juliana Campos; Rocha, Aroldo; Oliveira, Rodrigo Guimarães; Rizoli, Sandro B

    2009-05-01

    While mandatory surgery for all thoracoabdominal penetrating injuries is advocated by some, the high rate of unnecessary operations challenges this approach. However, the consequences of intrathoracic bile remains poorly investigated. We sought to evaluate the outcome of patients who underwent non-operative management of right side thoracoabdominal (RST) penetrating trauma, and the levels of bilirubin obtained from those patients' chest tube effluent. We managed non-operatively all stable patients with a single RST penetrating injury. Chest tube effluent samples were obtained six times within (4-8 h; 12-16 h; 20-24 h; 28-32 h; 36-40 h; 48 h and 72 h) of admission for bilirubin measurement and blood for complete blood count, bilirubin, alanine (ALT) and aspartate aminotransferases (AST) assays. For comparison we studied patients with single left thoracic penetrating injury. Forty-two patients with RST injuries were included. All had liver and lung injuries confirmed by CT scans. Only one patient failed non-operative management. Chest tube bilirubin peaked at 48 h post-trauma (mean 3.3+/-4.1 mg/dL) and was always higher than both serum bilirubin (pchest tube effluent from control group (27 patients with left side thoracic trauma). Serum ALT and AST were higher in RST injury patients (ptrauma appears to be safe. Bile originating from the liver injury reaches the right thoracic cavity but does not reflect the severity of that injury. The highest concentration was found in the patient failing non-operative management. The presence of intrathoracic bile in selected patients who sustain RST penetrating trauma, with liver injury, does not preclude non-operative management. Our study suggests that monitoring chest tube effluent bilirubin may provide helpful information when managing a patient non-operatively.

  5. Low protein content of drainage fluid is a good predictor for earlier chest tube removal after lobectomy.

    Science.gov (United States)

    Olgac, Guven; Cosgun, Tugba; Vayvada, Mustafa; Ozdemir, Atilla; Kutlu, Cemal Asim

    2014-10-01

    Owing to the great absorption capability of the pleura for transudates, the protein content of draining pleural fluid may be considered as a more adequate determinant than its daily draining amount in the decision-making for earlier chest tube removal. In an a priori pilot study, we observed that the initially draining protein-rich exudate converts to a transudate quickly in most patients after lobectomies. Thus, chest tubes draining high-volume but low-protein fluids can safely be removed earlier in the absence of an air leak. This randomized study aims to investigate the validity and clinical applicability of this hypothesis as well as its influence on the timing for chest tube removal and earlier discharge after lobectomy. Seventy-two consecutive patients undergoing straightforward lobectomy were randomized into two groups. Patients with conditions affecting postoperative drainage and with persisting air leaks beyond the third postoperative day were excluded. Drains were removed if the pleural fluid to blood protein ratio (PrRPl/B) was ≤0.5, regardless of its daily draining amount in the study arm (Group S; n = 38), and patients in the control arm (Group C; n = 34) had their tubes removed if daily drainage was ≤250 ml regardless of its protein content. Patients were discharged home immediately or the following morning after removal of the last drain. All cases were followed up regarding the development of symptomatic pleural effusions and hospital readmissions for a redrainage procedure. Demographic and clinical characteristics as well as the pattern of decrease in PrRPl/B were the same between groups. The mean PrRPl/B was 0.65 and 0.67 (95% CI = 0.60-0.69 and 0.62-0.72) on the first postoperative day, and it remarkably dropped down to 0.39 and 0.33 (95% CI = 0.33-0.45 and 0.27-0.39) on the second day in Groups S and C, respectively, and remained below 0.5 on the third day (repeated-measures of ANOVA design, post hoc 'within-group' comparison of the first

  6. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    Science.gov (United States)

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (Pauscultation to detect inadvertent endobronchial intubation. But even experienced physicians will benefit from inserting tubes to 20-21 cm in women and 22-23 cm in men, especially when high

  7. Implementation and Effectiveness of Early Chest Tube Removal during an Enhanced Recovery Programme after Oesophago-gastrectomy

    Directory of Open Access Journals (Sweden)

    Rajeev Bhandari

    2015-03-01

    Full Text Available Introduction: Oesophageal resection were notoriously complicated and produces a cohort of patients prone to postoperative complications and here we would like to focus on the implementation and effectiveness of early chest tube removal in ERAS after oesophago-gastrectomy considering the various aspect like pleural effusion and reducing the length of hospital stay which ultimately lead to reducing the economic burden on patient. Methods: An ERAS programme was devised and implemented with the support of a dedicated in-hospital task-force. The patients underwent esophago-gastrectomy were randomly divided into two groups: the ERAS group and the control group (non-ERAS. The ERAS group was treated with early removal of the chest tube after surgery, and the control group was treated with traditional way and outcomes were compared between them. Results: The length of hospital stay and the cost of hospitalization in the ERAS group were significantly lower than those in the control group(p<0.05. However, there was no statistical significant difference in the incidences of pleural effusion between the two groups(p>0.05. Conclusions: The introduction of early chest tube removal as an ERAS programme after oesophago-gastrectomy would not increase the risk of pleural effusion and would not increase the total length of stay and cost of hospitalisation without jeopardising patient safety or clinical outcomes.

  8. Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan

    International Nuclear Information System (INIS)

    Kim, Hyun Ju; Cho, Jae Hwan; Park, Cheol Soo

    2010-01-01

    The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). CT value of chest image increased at 100 kVp by 14.06%∼27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients

  9. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  10. Primary Chest Wall Abscess Mimicking a Breast Tumor That Occurred after Blunt Chest Trauma: A Case Report

    Science.gov (United States)

    Masuda, Norikazu; Yasojima, Hiroyuki; Mizutani, Makiko; Nakamori, Shoji; Kanazawa, Toru; Kuriyama, Keiko; Mano, Masayuki; Sekimoto, Mitsugu

    2014-01-01

    Primary chest wall abscess occurring after blunt chest trauma is rare. We present the case of a 50-year-old woman who presented with a swelling in her left breast. The patient had experienced blunt chest trauma 2 months back. Needle aspiration revealed pus formation in the patient's chest. Computed tomography revealed a mass in the lower region of the left mammary gland, with thickening of the parietal pleura and skin and fracture of the fifth rib under the abscess. Following antibiotic administration and irrigation of the affected region, surgical debridement was performed. During surgery, we found that the pectoralis major muscle at the level of the fifth rib was markedly damaged, although the necrotic tissue did not contact the mammary gland. We diagnosed the lesion as a chest wall abscess that occurred in response to blunt chest trauma. Her postoperative course was uneventful. There has been no recurrence for six months after surgery. PMID:24660001

  11. Primary Chest Wall Abscess Mimicking a Breast Tumor That Occurred after Blunt Chest Trauma: A Case Report

    Directory of Open Access Journals (Sweden)

    Yusuke Yamaoka

    2014-01-01

    Full Text Available Primary chest wall abscess occurring after blunt chest trauma is rare. We present the case of a 50-year-old woman who presented with a swelling in her left breast. The patient had experienced blunt chest trauma 2 months back. Needle aspiration revealed pus formation in the patient’s chest. Computed tomography revealed a mass in the lower region of the left mammary gland, with thickening of the parietal pleura and skin and fracture of the fifth rib under the abscess. Following antibiotic administration and irrigation of the affected region, surgical debridement was performed. During surgery, we found that the pectoralis major muscle at the level of the fifth rib was markedly damaged, although the necrotic tissue did not contact the mammary gland. We diagnosed the lesion as a chest wall abscess that occurred in response to blunt chest trauma. Her postoperative course was uneventful. There has been no recurrence for six months after surgery.

  12. Large pneumothorax in blunt chest trauma: Is a chest drain always necessary in stable patients? A case report.

    Science.gov (United States)

    Idris, Baig M; Hefny, Ashraf F

    2016-01-01

    Pneumothorax is the most common potentially life-threatening blunt chest injury. The management of pneumothorax depends upon the etiology, its size and hemodynamic stability of the patient. Most clinicians agree that chest drainage is essential for the management of traumatic large pneumothorax. Herein, we present a case of large pneumothorax in blunt chest trauma patient that resolved spontaneously without a chest drain. A 63- year- old man presented to the Emergency Department complaining of left lateral chest pain due to a fall on his chest at home. On examination, he was hemodynamically stable. An urgent chest X-ray showed evidence of left sided pneumothorax. CT scan of the chest showed pneumothorax of more than 30% of the left hemithorax (around 600ml of air) with multiple left ribs fracture. Patient refused tube thoracostomy and was admitted to surgical department for close observation. The patient was managed conservatively without chest tube insertion. A repeat CT scan of the chest has shown complete resolution of the pneumothorax. The clinical spectrum of pneumothorax varies from asymptomatic to life threatening tension pneumothorax. In stable patients, conservative management can be safe and effective for small pneumothorax. To the best of our knowledge, this is the second reported case in the English literature with large pneumothorax which resolved spontaneously without chest drain. Blunt traumatic large pneumothorax in a clinically stable patient can be managed conservatively. Current recommendations for tube placement may need to be reevaluated. This may reduce morbidity associated with chest tube thoracostomy. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. T-tube vs Primary Common Bile Duct Closure

    Directory of Open Access Journals (Sweden)

    M R Joshi

    2010-09-01

    Full Text Available INTRODUCTION: Closure of the common bile duct over T-tube after exploration is a widely practiced traditional method. However, its use may give rise to many complications. We do primary closure of common bile duct after exploration. Aim of the study is to see the efficacy and safety of the primary closure. METHODS: Study was carried out to compare the results of both the techniques from 2006 to 2009 in the cases proven to have common bile duct stone with or without the features of obstructive jaundice. Post operative hospital stay and morbidities related to both the groups were recorded and analyzed. RESULTS: There were total 71 cases included in the study. Thirty one in T-tube group and 40 in primary closure group. T-tube was removed in most of the cases after three weeks where as average time of drain removal in primary closure group is 5.79 +/-1.79 days. Incidence of retained stone was equal in each group. Major complication in T-tube group is biliary peritonitis in four patients at the time of T-tube removal whereas none of the patient from primary closure group suffered from such major complication. CONCLUSIONS: Primary closure after the common bile duct exploration is safe and it helps to avoid the morbidities related to T-tube. Keywords: Choledocholithiasis, Primary closure, retained stone, T-tube, Ureterorenoscope.

  14. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  15. Prehospital endotracheal intubation and chest tubing does not prolong the overall resuscitation time of severely injured patients: a retrospective, multicentre study of the Trauma Registry of the German Society of Trauma Surgery.

    Science.gov (United States)

    Kulla, Martin; Helm, Matthias; Lefering, Rolf; Walcher, Felix

    2012-06-01

    The aim of this study was to determine whether prehospital endotracheal intubation (ETI) and chest tube placement is unnecessarily time consuming in severely injured patients. A retrospective, multicentre study including all adult patients (ISS ≥9; 2002-7) of the Trauma Registry of the German Society of Trauma Surgery who were not secondarily transferred to a trauma centre and received a definitive airway and a chest tube. Creating four groups: AA (n=963) receiving ETI and chest tube on scene, AB (n=1547) ETI performed in the prehospital setting but chest tubing later in the emergency department (ED) and BB (n=640) receiving both procedures in the ED. The BA collective (ETI performed in the ED, but chest tubing on scene) was excluded from the study because of the small sample size (n=41). The trauma resuscitation time (TRT), demographic data, injuries, treatment and outcome of the remaining three collectives were compared. The prehospital TRT of the AA collective was longer than the AB and BB subgroups (80±37 min vs 77±44 min 65±46 min; pchest tube placement do not prolong the total TRT of severely injured patients.

  16. Diagnostic value of chest ultrasound after cardiac surgery: a comparison with chest X-ray and auscultation.

    Science.gov (United States)

    Vezzani, Antonella; Manca, Tullio; Brusasco, Claudia; Santori, Gregorio; Valentino, Massimo; Nicolini, Francesco; Molardi, Alberto; Gherli, Tiziano; Corradi, Francesco

    2014-12-01

    Chest auscultation and chest x-ray commonly are used to detect postoperative abnormalities and complications in patients admitted to intensive care after cardiac surgery. The aim of the study was to evaluate whether chest ultrasound represents an effective alternative to bedside chest x-ray to identify early postoperative abnormalities. Diagnostic accuracy of chest auscultation and chest ultrasound were compared in identifying individual abnormalities detected by chest x-ray, considered the reference method. Cardiac surgery intensive care unit. One hundred fifty-one consecutive adult patients undergoing cardiac surgery. All patients included were studied by chest auscultation, ultrasound, and x-ray upon admission to intensive care after cardiac surgery. Six lung pathologic changes and endotracheal tube malposition were found. There was a highly significant correlation between abnormalities detected by chest ultrasound and x-ray (k = 0.90), but a poor correlation between chest auscultation and x-ray abnormalities (k = 0.15). Chest auscultation may help identify endotracheal tube misplacement and tension pneumothorax but it may miss most major abnormalities. Chest ultrasound represents a valid alternative to chest x-ray to detect most postoperative abnormalities and misplacements. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    Science.gov (United States)

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p 30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  18. Early chest tube removal after video-assisted thoracic surgery lobectomy with serous fluid production up to 500 ml/day

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jensen, Katrine; Petersen, Rene Horsleben

    2014-01-01

    In fast-track pulmonary resections, we removed chest tubes after video-assisted thoracic surgery (VATS) lobectomy with serous fluid production up to 500 ml/day. Subsequently, we evaluated the frequency of recurrent pleural effusions requiring reintervention....

  19. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States); Ensor, Joe E. [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Mahvash, Armeen; Sabir, Sharjeel H.; Steele, Joseph R.; McRae, Stephen E.; Avritscher, Rony; Huang, Steven Y.; Odisio, Bruno C.; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J.; Tam, Alda L. [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  20. Thoracic Trauma: Which Chest Tube When and Where?

    Science.gov (United States)

    Molnar, Tamas F

    2017-02-01

    Clinical suspicion of hemo/pneumothorax: when in doubt, drain the chest. Stable chest trauma with hemo/pneumothorax: drain and wait. Unstable patient with dislocated trachea must be approached with drain in hand and scalpel ready. Massive hemo/pneumothorax may be controlled by drainage alone. The surgeon should not hesitate to open the chest if too much blood drains over a short period. The chest drainage procedure does not end with the last stitch; the second half of the match is still ahead. The drained patient is in need of physiotherapy and proper pain relief with an extended pleural space: control the suction system. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. "Anterior convergent" chest probing in rapid ultrasound transducer positioning versus formal chest ultrasonography to detect pneumothorax during the primary survey of hospital trauma patients: a diagnostic accuracy study.

    Science.gov (United States)

    Ziapour, Behrad; Haji, Houman Seyedjavady

    2015-01-01

    Occult pneumothorax represents a diagnostic pitfall during the primary survey of trauma patients, particularly if these patients require early positive pressure ventilation. This study investigated the accuracy of our proposed rapid model of ultrasound transducer positioning during the primary survey of trauma patients after their arrival at the hospital. This diagnostic trial was conducted over 12 months and was based on the results of 84 ultrasound (US) exams performed on patients with severe multiple trauma. Our index test (US) was used to detect pneumothorax in four pre-defined locations on the anterior of each hemi-thorax using the "Anterior Convergent" approach, and its performance was limited to the primary survey. Consecutively, patients underwent chest-computed tomography (CT) with or without chest radiography. The diagnostic findings of both chest radiography and chest ultrasounds were compared to the gold-standard test (CT). The diagnostic sensitivity was 78 % for US and 36.4 % for chest radiography (p chest radiography (not significant); the positive predictive values were 74 % for US and 80 % for chest radiography (not significant); the negative predictive values were 94 % for US and 87 % for chest radiography (not significant); the positive likelihood ratio was 10 for US and 18 for chest radiography (p = 0.007); and the negative likelihood ratio was 0.25 for US and 0.65 for chest radiography (p = 0.001). The mean required time for performing the new method was 64 ± 10 s. An absence of the expected diffused dynamic view among ultrasound images obtained from patients with pneumothorax was also observed. We designated this phenomenon "Gestalt Lung Recession." "Anterior convergent" chest US probing represents a brief but efficient model that provides clinicians a safe and accurate exam and adequate resuscitation during critical minutes of the primary survey without interrupting other medical staff activities taking place around the

  2. Primary Bilateral Fallopian Tube Adenocarcinoma - A Case Report

    Directory of Open Access Journals (Sweden)

    Jaya Manchanda

    2015-01-01

    Full Text Available Cancer of the fallopian tube accounts for <0.1% of all gynaecologic cancers. Primary adenocarcinoma of the fallopian tube is usually unilateral , extremely rare that clinically and histologically resembles epithelial ovarian cancer(EOC.It is more common for cancer to spread or metastasize from ovaries or endometrium, than for cancer to actually originate in the fallopian tubes. Some of the common symptoms are abnormal vaginal bleeding, abdominal pain, abnormal vaginal discharge and pelvic mass which are present in up to two-thirds of patients and may mimic those of other gynecological problems. So we are presenting a rare case of stage IB primary fallopian tube cancer which is difficult to diagnose early.

  3. Evaluation of the individual tube current setting in electrocardiogram-gated cardiac computed tomography estimated from plain chest computed tomography using computed tomography automatic exposure control

    International Nuclear Information System (INIS)

    Kishimoto, Junichi; Sakou, Toshio; Ohta, Yasutoshi

    2013-01-01

    The aim of this study was to estimate the tube current on a cardiac computed tomography (CT) from a plain chest CT using CT-automatic exposure control (CT-AEC), to obtain consistent image noise, and to optimize the scan tube current by individualizing the tube current. Sixty-five patients (Group A) underwent cardiac CT at fixed tube current. The mAs value for plain chest CT using CT-AEC (AEC value) and cardiac CT image noise were measured. The tube current needed to obtain the intended level of image noise in the cardiac CT was determined from their correlation. Another 65 patients (Group B) underwent cardiac CT with tube currents individually determined from the AEC value. Image noise was compared among Group A and B. Image noise of cardiac CT in Group B was 24.4±3.1 Hounsfield unit (HU) and was more uniform than in Group A (21.2±6.1 HU). The error with the desired image noise of 25 HU was lower in Group B (2.4%) than in Group A (15.2%). Individualized tube current selection based on AEC value thus provided consistent image noise and a scan tube current optimized for cardiac CT. (author)

  4. Bradycardia after Tube Thoracostomy for Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Yomi Fashola

    2018-01-01

    Full Text Available We present the case of an elderly patient who became bradycardic after chest tube insertion for spontaneous pneumothorax. Arrhythmia is a rare complication of tube thoracostomy. Unlike other reported cases of chest tube induced arrhythmias, the bradycardia in our patient responded to resuscitative measures without removal or repositioning of the tube. Our patient, who had COPD, presented with shortness of breath due to spontaneous pneumothorax. Moments after tube insertion, patient developed severe bradycardia that responded to Atropine. In patients requiring chest tube insertion, it is important to be prepared to provide cardiopulmonary resuscitative therapy in case the patient develops a life-threatening arrhythmia.

  5. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, D.J., E-mail: daniel.shaw@christie.nhs.uk [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom); Crawshaw, I. [Diagnostic X-ray Department, York Teaching Hospital NHS Foundation Trust, The York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Rimmer, S. D. [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom)

    2013-11-15

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV{sub p}) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV{sub p} relative to 109 kV{sub p}, though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p < 0.01). For FPD imaging the anti-scatter grid offered slightly improved image quality relative to the air gap (p = 0.038) but this was not seen for CR (p = 0.404). Conclusions: For FPD chest imaging of the anthropomorphic phantom there was no dependence of image quality on tube potential. Scatter rejection improved image quality, with the anti-scatter grid giving greater improvements than an air-gap, but at the expense of increased effective dose. CR imaging of the chest phantom demonstrated negligible dependence on tube potential except at 125 kV{sub p}. Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique.

  6. Primary adenocarcinoma of the fallopian tube: a case series

    Directory of Open Access Journals (Sweden)

    Kemal Güngördük

    2007-09-01

    Full Text Available Primary fallopian tube carcinoma is a rare tumor that histologically and clinically resembles primary ovarian carcinoma. In this article, seven patients with primary fallopian tube carcinoma who were managed at our clinic between 2002 and 2007 were evaluated. All cases were treated by total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy,appendectomy and lymph node dissection followed by chemotherapy. Fallopian tube carcinoma is rarely suspected preoperatively. The symptom complex of ‘hydrops tubae profluence’, said to be pathognomonic for this tumor, is rarely encountered. Appropriate therapy for each stage of the disease should be defined, and further studies are required to better depict the clinical course and; prognostic factors.

  7. Risks of Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Screening

    Science.gov (United States)

    ... black women. Different factors increase or decrease the risk of getting ovarian, fallopian tube, and primary peritoneal ... decrease the number of deaths from ovarian cancer. Risks of Ovarian, Fallopian Tube, and Primary Peritoneal Cancer ...

  8. Thermal optimization of primary side in double-tube OTSG

    International Nuclear Information System (INIS)

    Wei Xinyu; Dai Chunhui; Hou Suxia; Tai Yun; Zhao Fuyu

    2011-01-01

    Once-through steam generator (OTSG) is usually used in the integrated nuclear power plants which require smaller volume and better effect of heat transfer. The double-tube OTSG component which is composed of straight tube outside and helical tube inside is presented in this paper. The primary fluid is divided into two parts, one is in the inner tube and the other is in the gap among outer tubes. The flow distribution ratio of the primary fluid obviously affects the heat transfer. Thus, the problem of optimization emerges, i.e. how to find an optimal flow distribution ratio with a maximum heat exchange. Analyzed the effects of the distribution ratio on heat transfer, the optimal distribution ratio is obtained by the constrained nonlinear optimization method. Subsequently, the optimal distribution ratio is achieved by a throttling set in the entrance of the inner tube. The result is in substantial agreement with the literature. (author)

  9. Primary infiltrating ductal carcinoma of the axillary breast with metastasis to the contralateral chest wall

    Directory of Open Access Journals (Sweden)

    Li-Min Sun

    2013-06-01

    Full Text Available Primary infiltrating ductal carcinoma of the axillary breast is rare and has a high frequency of lymph node (LN involvement. We report a woman with primary infiltrating ductal carcinoma arising from the right axillary breast with metastasis to the contralateral chest wall. Excisional biopsy of the left chest wall nodule and the right axillary mass was carried out and both showed invasive ductal carcinomas histologically. The lesion of the right axillary mass arose from the breast tissue, rather than the LN. Further surgery proved the right axillary LN metastasis. After further review, a primary infiltrating ductal carcinoma of the right axillary breast with metastasis to axillary LNs and contralateral chest wall was diagnosed. The patient also received chemotherapy and radiation and there was no evidence of tumor recurrence after treatment. The present report demonstrated a rare case with uncommon manifestation. Lesions of uncertain origin around the periphery of the breast should be suspected for breast carcinoma.

  10. Large pneumothorax in blunt chest trauma: Is a chest drain always necessary in stable patients? A case report

    Directory of Open Access Journals (Sweden)

    Baig M. Idris

    2016-01-01

    Conclusion: Blunt traumatic large pneumothorax in a clinically stable patient can be managed conservatively. Current recommendations for tube placement may need to be reevaluated. This may reduce morbidity associated with chest tube thoracostomy.

  11. Penetrating chest injury: A miraculous life salvage

    Directory of Open Access Journals (Sweden)

    Santosh B Dalavi

    2013-01-01

    Full Text Available An unusual penetrating chest injury was caused by high velocity road traffic accident. An 18-year-old had a four wheeler accident and was brought in emergency department with a ′bamboo′ stick on the left side chest exiting through back. After the stabilization of vital parameters, an inter-costal tube drainage was done on the left side. Except the minor brochopleural fistula which healed by 10 th day, his recovery was uneventful. The outcome was consistent with current aggressive management of penetrating chest injuries. Management of penetrating chest injury involving pulmonary trauma is based on three principles. One is stabilization of hemodynamics of patient with proper clinical evaluation. Second, a mere intercostal tube drainage sufficient for majority of the cases. Third, post-operative active as well as passive physiotherapy is necessary for speedy recovery.

  12. Patient-specific radiation dose and cancer risk for pediatric chest CT.

    Science.gov (United States)

    Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P

    2011-06-01

    To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011

  13. Use of the iTClamp versus standard suturing techniques for securing chest tubes: A randomized controlled cadaver study

    Directory of Open Access Journals (Sweden)

    Jessica Mckee

    2018-03-01

    Full Text Available Objectives: Tube thoracostomy (TT is a common yet potentially life-saving trauma procedure. After successful placement however, securing a TT through suturing is a skillset that requires practice, risking that the TT may become dislodged during prehospital transport. The purpose of this study was to examine if the iTClamp was a simpler technique with equivalent effectiveness for securing TTs. Materials and methods: In a cadaver model, a 1.5 inch incision was utilized along the upper border of the rib below the 5th intercostal space at the anterior axillary line. TTs (sizes 28Fr, 32Fr, 36Fr and 40Fr were inserted and secured with both suturing and iTClamp techniques according to the preset randomization. TT were then functionally tested for positive and negative pressure as well as the force required to remove the TT (pull test-up to 5 lbs. Time to secure the TT was also recorded. Results: When sutured is placed by a trained surgeon, the sutures and iTClamp were functionally equivalent for holding a positive and negative pressure. Mean pull force for both sutures and iTClamp exceeded the 5 lb threshold; there was no significant difference between the groups. Securing the TT with the iTClamp was significantly faster (p < 0.0001 with the iTClamp having a mean application time of 37.0 ± 22.8 s and using a suture had a man application time of 96.3 ± 29.0 s. Conclusion: The iTClamp was effective in securing TTs. The main benefit to the iTClamp is that minimal skill is required to adequately secure a TT to ensure that it does not become dislodged during transport to a trauma center. Keywords: Chest tube, Tube thoracostomy, Securing chest tubes

  14. Serous ovarian, fallopian tube and primary peritoneal cancers

    DEFF Research Database (Denmark)

    Sørensen, Rie D; Schnack, Tine H; Karlsen, Mona A

    2015-01-01

    OBJECTIVE: The aim of this systematic review is to analyze data on risk factors, epidemiology, clinicopathology and molecular biology from studies comparing primary peritoneal cancer, fallopian tube cancer and ovarian cancer of serous histology, in order to achieve a greater understanding...... of whether or not these disorders should be considered as separate entities. METHODS: A systematic literature search was conducted in PubMed and MEDLINE. Case-control studies comparing primary serous peritoneal or fallopian tube carcinomas with primary serous ovarian carcinomas or a control group were...... included. RESULTS: Twenty-eight studies were found eligible. Primary peritoneal cancer patients were older, had higher parity, were more often obese and had poorer survival compared to ovarian cancer patients. Differences in protein expression patterns of Her2/neu, estrogen and progestin receptors...

  15. Chest Tomosynthesis: Technical Principles and Clinical Update

    Science.gov (United States)

    Dobbins, James T.; McAdams, H. Page

    2009-01-01

    Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the x-ray tube. It utilizes a conventional x-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosynthesis provides some of the tomographic benefits of CT but at lower cost and radiation dose than CT. Compared to conventional chest radiography, chest tomosynthesis results in improved visibility of normal structures such as vessels, airway and spine. By reducing visual clutter from overlying normal anatomy, it also enhances detection of small lung nodules. This review article outlines the components of a tomosynthesis system, discusses results regarding improved lung nodule detection from the recent literature, and presents examples of nodule detection from a clinical trial in human subjects. Possible implementation strategies for use in clinical chest imaging are discussed. PMID:19616909

  16. Utility of Objective Chest Tube Management After Pulmonary Resection Using a Digital Drainage System.

    Science.gov (United States)

    Takamochi, Kazuya; Imashimizu, Kota; Fukui, Mariko; Maeyashiki, Tatsuo; Suzuki, Mikiko; Ueda, Takuya; Matsuzawa, Hironori; Hirayama, Shunki; Matsunaga, Takeshi; Oh, Shiaki; Suzuki, Kenji

    2017-07-01

    We sought to evaluate the clinical utility of chest tube management after pulmonary resection based on objective digital monitoring of pleural pressure and digital surveillance for air leaks. We prospectively recorded the perioperative data of 308 patients who underwent pulmonary resection between December 2013 and January 2016. We used information from a digital monitoring thoracic drainage system to measure peak air leakage during the first 24 hours after the operation, patterns of air leakage over the first 72 hours, and patterns of pleural pressure changes until the chest tubes were removed. There were 240 patients with lung cancer and 68 patients with other diseases. The operations included 49 wedge resections, 58 segmentectomies, and 201 lobectomies. A postoperative air leak was observed in 61 patients (20%). A prolonged air leak exceeding 20 mL/min lasting 5 days or more was observed in 18 patients (5.8%). Multivariate analysis of various perioperative factors showed forced expiratory volume in 1 second below 70%, patterns of air leakage, defined as exacerbating and remitting or without a trend toward improvement, and peak air leakage of 100 mL/min or more were significant positive predictors of prolonged air leak. Fluctuations in pleural pressure occurred just after the air leakage rate decreased to less than 20 mL/min. Digital monitoring of peak air leakage and patterns of air leakage were useful for predicting prolonged air leak after pulmonary resection. Information on the disappearance of air leak could be derived from the change in the rate of air leakage and from the increase in fluctuation of pleural pressure. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Prevalence and Clinical Import of Thoracic Injury Identified by Chest Computed Tomography but Not Chest Radiography in Blunt Trauma: Multicenter Prospective Cohort Study.

    Science.gov (United States)

    Langdorf, Mark I; Medak, Anthony J; Hendey, Gregory W; Nishijima, Daniel K; Mower, William R; Raja, Ali S; Baumann, Brigitte M; Anglin, Deirdre R; Anderson, Craig L; Lotfipour, Shahram; Reed, Karin E; Zuabi, Nadia; Khan, Nooreen A; Bithell, Chelsey A; Rowther, Armaan A; Villar, Julian; Rodriguez, Robert M

    2015-12-01

    Chest computed tomography (CT) diagnoses more injuries than chest radiography, so-called occult injuries. Wide availability of chest CT has driven substantial increase in emergency department use, although the incidence and clinical significance of chest CT findings have not been fully described. We determine the frequency, severity, and clinical import of occult injury, as determined by changes in management. These data will better inform clinical decisions, need for chest CT, and odds of intervention. Our sample included prospective data (2009 to 2013) on 5,912 patients at 10 Level I trauma center EDs with both chest radiography and chest CT at physician discretion. These patients were 40.6% of 14,553 enrolled in the parent study who had either chest radiography or chest CT. Occult injuries were pneumothorax, hemothorax, sternal or greater than 2 rib fractures, pulmonary contusion, thoracic spine or scapula fracture, and diaphragm or great vessel injury found on chest CT but not on preceding chest radiography. A priori, we categorized thoracic injuries as major (having invasive procedures), minor (observation or inpatient pain control >24 hours), or of no clinical significance. Primary outcome was prevalence and proportion of occult injury with major interventions of chest tube, mechanical ventilation, or surgery. Secondary outcome was minor interventions of admission rate or observation hours because of occult injury. Two thousand forty-eight patients (34.6%) had chest injury on chest radiography or chest CT, whereas 1,454 of these patients (71.0%, 24.6% of all patients) had occult injury. Of these, in 954 patients (46.6% of injured, 16.1% of total), chest CT found injuries not observed on immediately preceding chest radiography. In 500 more patients (24.4% of injured patients, 8.5% of all patients), chest radiography found some injury, but chest CT found occult injury. Chest radiography found all injuries in only 29.0% of injured patients. Two hundred and two

  18. Choledochorraphy (primary repair) versus t-tube drainage after open choledochotomy

    International Nuclear Information System (INIS)

    Saeed, N.; Tauqeer, M.; Khan, M.I.; Channa, G.A.

    2012-01-01

    Background: T-tube drainage used to be standard practice after surgical choledochotomy, but there is now a tendency in some canters to close the common bile duct primarily. This study was designed to compare the clinical results of primary closure with T-tube drainage after open choledocotomy and assess the safety of primary closure for future application. Methods: This study was conducted at surgical Unit-3, ward 26 Jinnah Postgraduate Medical Centre Karachi, from January 2007 to January 2008. Forty patients were included in this study out of which 20 underwent primary closure and 20 T-tube placements. It was Quasi-experimental, non-probability, purposive sampling. Main outcome measures were operating time, duration of hospital stay, and postoperative complications. SPSS-10 was used for data analysis. Results: The age of patients in the study ranged from 29-83 years. There were 3 male while 37 female patients. Group-1 consisted of 20 patients underwent primary closure after choledocotomy, while Group-2 also consisted of 20 patients underwent T-tube drainage after duct exploration. Mean hospital stay in Group-1 patients was 7.63 days while in group 2 it was 13.6 days. Overall complication rate in group 1 was 15%, biliary leakage in 1 (5%), jaundice in 1 (5%), wound infection in 1 (5%). No re-exploration was required in Group-1. In Group-2 overall complication rate was 30%, biliary leakage in 2 (2%), jaundice in 1 (5%), dislodgement of T-tube in 1 (5%), wound infection in 1 (5%), and sepsis in 1 (5%) patients. Re-exploration was done in one patient. Conclusion: Primary closure of Common Bile Duct (CBD) is a safe and cost-effective alternative procedure to routine T-tube drainage after open choledocotomy. (author)

  19. High-Temperature Graphitization Failure of Primary Superheater Tube

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  20. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  1. MINIMALLY-INVASIVE TUBE THORACOSTOMY MADE EASY WITH A COMBINATION OF THORACIC ULTRASOUND AND SMALL BORE CHEST DRAIN KITS (12F TO 16F USING GUIDEWIRE TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Venkateswararao

    2017-11-01

    Full Text Available BACKGROUND Minimally-invasive tube thoracostomy made easy with a combination of thoracic ultrasound and small bore chest drain kits (12F to16F using guidewire technique. The present study is aimed at easy and safe insertion of small bore chest drains (12F to 16F using Seldinger technique under ultrasound guidance with least discomfort to the patient. Large bore chest drains of size >20F using blunt dissection technique is painful, difficult to place in thick chest walls and technically more demanding. Placing the drains blindly basing on chest x-ray image may sometimes injure the underlying lung. MATERIALS AND METHODS Present study included 21 cases, of which 12 cases (57.1% were of pleural effusion and 9 cases (42.8% were of pneumothorax. Thoracic ultrasound was utilised by the operator for all pleural effusions and for those cases of pneumothorax who were on ventilator before tube insertion. Small bore chest drains (12F to 16F designed for guidewire technique were used in the present study. RESULTS Complete and sustainable lung expansion was seen in 19 of 21 cases (90.4%. It failed in remaining 2 cases (9.5% who had complex empyemas and hepatic hydrothorax. Pleurodesis was attempted in 6 cases (28.5% using tetracycline injectable form with success rate of 90%. Patient tolerance was good with numeric pain rating score of 1 to 3 (range 0 to 10; 0 = no pain; 5 = moderate pain; 10 = worst possible pain. CONCLUSION Using small bore chest tubes of sizes 12F to 16F designed for guidewire technique of insertion and utilising thoracic ultrasound, while insertion made the procedure easy and safe, less painful and good tolerance from patient’s point of view. Complete and sustainable lung expansion was seen in 90.4% of cases and highly efficacious for spontaneous and iatrogenic pneumothorax and in noncomplex and malignant pleural effusions. The technique is less demanding and thoracic ultrasound knowledge can be easily learnt and a combination of this

  2. Primary carcinosarcoma of the fallopian tube: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyeon Wook [Dept. of Radiology, Daegu Fatima Hospital, Daegu (Korea, Republic of); Kim, See Hyung; Kwon, Sun Young [Dept. of Radiology, Keimyung University School of Medicine, Dongsan Medical Center, Daegu (Korea, Republic of)

    2017-08-15

    Carcinosarcomas are biphasic neoplasms composed of epithelial and mesenchymal elements. They are most commonly found in the uterus, with rare involvement of the fallopian tubes. Here, we present a case of primary carcinosarcoma of the fallopian tube. On CT and MRI imaging, it manifested as a tubular heterogeneous enhancing mass, along with necrosis and hemorrhage.

  3. Combining automatic tube current modulation with adaptive statistical iterative reconstruction for low-dose chest CT screening.

    Science.gov (United States)

    Chen, Jiang-Hong; Jin, Er-Hu; He, Wen; Zhao, Li-Qin

    2014-01-01

    To reduce radiation dose while maintaining image quality in low-dose chest computed tomography (CT) by combining adaptive statistical iterative reconstruction (ASIR) and automatic tube current modulation (ATCM). Patients undergoing cancer screening (n = 200) were subjected to 64-slice multidetector chest CT scanning with ASIR and ATCM. Patients were divided into groups 1, 2, 3, and 4 (n = 50 each), with a noise index (NI) of 15, 20, 30, and 40, respectively. Each image set was reconstructed with 4 ASIR levels (0% ASIR, 30% ASIR, 50% ASIR, and 80% ASIR) in each group. Two radiologists assessed subjective image noise, image artifacts, and visibility of the anatomical structures. Objective image noise and signal-to-noise ratio (SNR) were measured, and effective dose (ED) was recorded. Increased NI was associated with increased subjective and objective image noise results (PASIR levels (PASIR had average subjective image noise scores and nearly average anatomical structure visibility scores, with a mean objective image noise of 23.42 HU. The EDs for groups 1, 2, 3 and 4 were 2.79 ± 1.17, 1.69 ± 0.59, 0.74 ± 0.29, and 0.37 ± 0.22 mSv, respectively. Compared to group 1 (NI = 15), the ED reductions were 39.43%, 73.48%, and 86.74% for groups 2, 3, and 4, respectively. Using NI = 30 with 50% ASIR in the chest CT protocol, we obtained average or above-average image quality but a reduced ED.

  4. Occult pneumomediastinum in blunt chest trauma: clinical significance.

    Science.gov (United States)

    Rezende-Neto, J B; Hoffmann, J; Al Mahroos, M; Tien, H; Hsee, L C; Spencer Netto, F; Speers, V; Rizoli, S B

    2010-01-01

    Thoracic injuries are potentially responsible for 25% of all trauma deaths. Chest X-ray is commonly used to screen patients with chest injury. However, the use of computed tomography (CT) scan for primary screening is increasing, particularly for blunt trauma. CT scans are more sensitive than chest X-ray in detecting intra-thoracic abnormalities such as pneumothoraces and pneumomediastinums. Pneumomediastinum detected by chest X-ray or "overt pneumomediastinum", raises the concern of possible aerodigestive tract injuries. In contrast, there is scarce information on the clinical significance of pneumomediastinum diagnosed by CT scan only or "occult pneumomediastinum". Therefore we investigated the clinical consequences of occult pneumomediastinum in our blunt trauma population. A 2-year retrospective chart review of all blunt chest trauma patients with initial chest CT scan admitted to a level I trauma centre. Data extracted from the medical records include; demographics, occult, overt, or no pneumomediastinum, the presence of intra-thoracic aerodigestive tract injuries (trachea, bronchus, and/or esophagus), mechanism and severity of injury, endotracheal intubation, chest thoracostomy, operations and radiological reports by an attending radiologist. All patients with intra-thoracic aerodigestive tract injuries from 1994 to 2004 were also investigated. Of 897 patients who met the inclusion criteria 839 (93.5%) had no pneumomediastinum. Five patients (0.6%) had overt pneumomediastinum and 53 patients (5.9%) had occult pneumomediastinum. Patients with occult pneumomediastinum had significantly higher ISS and AIS chest (pchest thoracostomy tube was more common (ppneumothorax. None of the patients with occult pneumomediastinum had aerodigestive tract injuries (95%CI 0-0.06). Follow up CT scan of patients with occult pneumomediastinum showed complete resolution in all cases, in average 3 h after the initial exam. Occult pneumomediastinum occurred in approximately 6% of

  5. Unjoined primary and secondary neural tubes: junctional neural tube defect, a new form of spinal dysraphism caused by disturbance of junctional neurulation.

    Science.gov (United States)

    Eibach, Sebastian; Moes, Greg; Hou, Yong Jin; Zovickian, John; Pang, Dachling

    2017-10-01

    Primary and secondary neurulation are the two known processes that form the central neuraxis of vertebrates. Human phenotypes of neural tube defects (NTDs) mostly fall into two corresponding categories consistent with the two types of developmental sequence: primary NTD features an open skin defect, an exposed, unclosed neural plate (hence an open neural tube defect, or ONTD), and an unformed or poorly formed secondary neural tube, and secondary NTD with no skin abnormality (hence a closed NTD) and a malformed conus caudal to a well-developed primary neural tube. We encountered three cases of a previously unrecorded form of spinal dysraphism in which the primary and secondary neural tubes are individually formed but are physically separated far apart and functionally disconnected from each other. One patient was operated on, in whom both the lumbosacral spinal cord from primary neurulation and the conus from secondary neurulation are each anatomically complete and endowed with functioning segmental motor roots tested by intraoperative triggered electromyography and direct spinal cord stimulation. The remarkable feature is that the two neural tubes are unjoined except by a functionally inert, probably non-neural band. The developmental error of this peculiar malformation probably occurs during the critical transition between the end of primary and the beginning of secondary neurulation, in a stage aptly called junctional neurulation. We describe the current knowledge concerning junctional neurulation and speculate on the embryogenesis of this new class of spinal dysraphism, which we call junctional neural tube defect.

  6. Low-dosage helical CT applications for chest medical checkup and lung cancer screening

    International Nuclear Information System (INIS)

    Wang Ping; Cui Fa; Liang Huanqing; Zheng Minfei

    2005-01-01

    Objective: A discussion on low-dosage helical CT applications on chest medical checkup and lung cancer screening. Methods: On the 100 chest medical check up with three different of protocols, including standard-dosage (the tube current was 230 mAs) were compared with low-dose (tube current was 50 mAs or 30 mAs). Results: Low-dosage helical CT scan provides excellent images. In 100 chest medical checkup, 39 nodules or masses were revealed, enlarged lymph node was noted in 1 case; emphysema or bullae was demonstrated in 3 segments; thickening of bronchial wall was shown in 2 cases; and localized pleural thickening was found in 1 case. Conclusion: In chest checkup or lung cancer screening low-dosage helical CT (tube current 30 mAs) will not only guarantee image quality but also reduce the radiation dose during the examination. (authors)

  7. Primary carcinoma of the Fallopian tubes

    International Nuclear Information System (INIS)

    Escalona Veloz, Rafael; Lopez Rodriguez, Caridad; Nunnez Quintana, Adrian; Rizo Reve, Rafael

    2010-01-01

    The clinical case of a 53 year old patient with history of vaginal bleeding for possible uterine fibroma is described. A total hysterectomy with double ooferectomia was performed. The complementary tests results, including the biopsy, confirmed the presence of a primary carcinoma of the right Fallopian tube. A radiotherapy and follow up were indicated in 'Conrado Benitez' Oncology Hospital from Santiago de Cuba

  8. Primary chest wall Hydatid cyst: Review of literature with report of a new case

    Directory of Open Access Journals (Sweden)

    Abdulwahid M. Salih

    Full Text Available Introduction: Hydatid cyst is a parasitic disease caused by Echinococci. The most commonly affected organ is liver, followed by lungs. Hydatid disease of the chest wall is extremely rare. The aim of this study is to report a case of chest wall Hydatid cyst with literature review. A 20-year-old pregnant lady presented with left hypochondrial and lower chest painful swelling. There was 10 × 15 centimeters, tender mass with features suggestive of abscess. The patient refused every sort of radiological examination. Under general anesthesia, oblique incision was done, on opening, clear fluid came out, with deep incision pus-like fluid and many daughter cysts drained. Complete evacuation of the cyst was done with closure of the residual cavity. The patient refused chemoprophylaxis because of her pregnancy. Conclusion: primary chest wall Hydatid cyst is a very rare disease in endemic areas. Mass and pain are the most common presentation. Excision under general anesthesia is main modality of treatment. Keywords: Hydatid cyst, Pregnancy, Albendazole

  9. Primary Fallopian Tube Carcinoma: A Case Report and Literature Review.

    Science.gov (United States)

    Rexhepi, Meral; Trajkovska, Elizabeta; Ismaili, Hysni; Besimi, Florin; Rufati, Nagip

    2017-06-15

    Primary fallopian tube carcinoma (PFTC) is a rare tumour of the female genital tract with an incidence of 0.1-1.8% of all genital malignancies, and it is very difficult to diagnose preoperatively, because of its non-specific symptomatology. In most cases, it is an intraoperative finding or a histopathological diagnosis. It is a tumour that histologically and clinically resembles epithelial ovarian cancer. We are reporting a case of a 62-year-old, postmenopausal women with primary fallopian tube carcinoma of the right fallopian tube in stage IA. The patient has lower abdominal pain, watery vaginal discharge and repeated episodes of bleeding from the vagina. The clinical and radiological findings suggested a right adnexal tumour with elevated CA-125 levels. Total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy and peritoneal washing were performed. Pathologic confirmation of primary serous cystadenocarcinoma of the right fallopian tube was made. Peritoneal washings were negative for malignancy. FIGO stage was considered as IA, and the patient received no courses of chemotherapy and postoperative radiation because she refused it. Ten months after initial surgery, the patient is alive and in good condition. Cytoreduction surgery followed by adequate cycles of chemotherapy is an important strategy to improve patients' prognosis.

  10. Interpretation of neonatal chest radiography

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung

    2016-01-01

    Plain radiographs for infants in the neonatal intensive care unit are obtained using the portable X-ray equipment in order to evaluate the neonatal lungs and also to check the position of the tubes and catheters used for monitoring critically-ill neonates. Neonatal respiratory distress is caused by a variety of medical or surgical disease conditions. Clinical information about the gestational week, respiratory symptoms, and any events during delivery is essential for interpretation of the neonatal chest radiographs. Awareness of common chest abnormality in the prematurely born or term babies is also very important for chest evaluation in the newborn. Furthermore, knowledge about complications such as air leaks and bronchopulmonary dysplasia following treatment are required to accurately inform the clinicians. The purpose of this article was to briefly review radiographic findings of chest diseases in newborns that are relatively common in daily practice

  11. Interpretation of neonatal chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hye Kyung [Dept. of Radiology, Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2016-05-15

    Plain radiographs for infants in the neonatal intensive care unit are obtained using the portable X-ray equipment in order to evaluate the neonatal lungs and also to check the position of the tubes and catheters used for monitoring critically-ill neonates. Neonatal respiratory distress is caused by a variety of medical or surgical disease conditions. Clinical information about the gestational week, respiratory symptoms, and any events during delivery is essential for interpretation of the neonatal chest radiographs. Awareness of common chest abnormality in the prematurely born or term babies is also very important for chest evaluation in the newborn. Furthermore, knowledge about complications such as air leaks and bronchopulmonary dysplasia following treatment are required to accurately inform the clinicians. The purpose of this article was to briefly review radiographic findings of chest diseases in newborns that are relatively common in daily practice.

  12. Intercostal drainage tube or intracardiac drainage tube?

    Science.gov (United States)

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  13. AIRFIX: the first digital postoperative chest tube airflowmetry--a novel method to quantify air leakage after lung resection.

    Science.gov (United States)

    Anegg, Udo; Lindenmann, Jorg; Matzi, Veronika; Mujkic, Dzenana; Maier, Alfred; Fritz, Lukas; Smolle-Jüttner, Freyja Maria

    2006-06-01

    Prolonged air leak after pulmonary resection is a common complication and a major limiting factor for early discharge from hospital. Currently there is little consensus on its management. The aim of this study was to develop and evaluate a measuring device which allows a simple digital bed-side quantification of air-leaks compatible to standard thoracic drainage systems. The measuring device (AIRFIX) is based upon a 'mass airflow' sensor with a specially designed software package that is connected to a thoracic suction drainage system. Its efficacy in detecting pulmonary air-leaks was evaluated in a series of 204 patients; all postoperative measurements were done under standardized conditions; the patients were asked to cough, to take a deep breath, to breathe out against the resistance of a flutter valve, to keep breath and to breathe normally. As standard parameters, the leakage per breath or cough (ml/b) as well as the leakage per minute (ml/min) were displayed and recorded on the computer. Air-leaks within a range of 0.25-45 ml/b and 5-900 ml/min were found. Removal of the chest tubes was done when leakage volume on Heimlich valve was less than 1.0 ml/b or 20 ml/min. After drain removal based upon the data from chest tube airflowmetry none of the patients needed re-drainage due to pneumothorax. The AIRFIX device for bed-side quantification of air-leaks has proved to be very simple and helpful in diagnosis and management of air-leaks after lung surgery, permitting drain removal without tentative clamping.

  14. Frequency of chest pain in primary care, diagnostic tests performed and final diagnoses.

    Science.gov (United States)

    Hoorweg, Beatrijs Bn; Willemsen, Robert Ta; Cleef, Lotte E; Boogaerts, Tom; Buntinx, Frank; Glatz, Jan Fc; Dinant, Geert Jan

    2017-11-01

    Observational study of patients with chest pain in primary care: determination of incidence, referral rate, diagnostic tests and (agreement between) working and final diagnoses. 118 general practitioners (GPs) in the Netherlands and Belgium recorded all patient contacts during  2weeks. Furthermore, patients presenting with chest pain were registered extensively. A follow-up form was filled in after 30 days. 22 294 patient contacts were registered. In 281 (1.26%), chest pain was a reason for consulting the GP (mean age for men 54.4/women 53 years). In this cohort of 281 patients, in 38.1% of patients, acute coronary syndrome (ACS) was suspected at least temporarily during consultation, 40.2% of patients were referred to secondary care and 512 diagnostic tests were performed by GPs and consulted specialists. Musculoskeletal pain was the most frequent working (26.1%) and final diagnoses (33.1%). Potentially life-threatening diseases as final diagnosis (such as myocardial infarction) accounted for 8.4% of all chest pain cases. In 23.1% of cases, a major difference between working and final diagnoses was found, in 0.7% a severe disease was initially missed by the GP. Chest pain was present in 281 patients (1.26% of all consultations). Final diagnoses were mostly non-life-threatening. Nevertheless, in 8.4% of patients with chest pain, life-threatening underlying causes were identified. This seems reflected in the magnitude and wide variety of diagnostic tests performed in these patients by GPs and specialists, in the (safe) overestimation of life-threatening diseases by GPs at initial assessment and in the high referral rate we found. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Early Removal of Drainage Tube after Fast-Track Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Zhang, Shaoyun; Xu, Bin; Huang, Qiang; Yao, Huan; Xie, Jinwei; Pei, Fuxing

    2017-07-01

    There is no consensus as to whether drainage tube should be used and how long it should remain in use after primary total knee arthroplasty (TKA). As fast-track (FT) program has been implemented in TKA, whether drainage tube could be removed early, and the ideal timing for removal after FT primary TKA has been a new topic. The purpose of this prospective cohort study was to evaluate the safety and feasibility of early removal of drainage tube when FT program was implemented in primary TKA. A total of 101 patients undergoing FT primary TKA were prospectively allocated into three groups. Patients in group A (31 patients) indwelled wound drainage tube for 6 hours after surgery while group B (34 patients) for 12 hours and group C (36 patients) for 18 hours. The knee circumference, resting and moving visual analogue score (VAS), hemoglobin (Hb), hematocrit, white blood count (WBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), interleukin-6 (IL-6), the volume of blood loss and drainage, and postoperative length of stay (LOS) among three groups were recorded and compared. There was no statistically significant difference in the volume of total and hidden blood loss among three groups ( p  > 0.05), but as the time of drainage prolonged, total volume of drainage and dominant blood loss increased gradually ( p   0.05), the decrease of Hb in the perioperative period and postoperative LOS as well. Early removal of wound drainage tube could drain the hematocele and reduce the risk of infection, and it doesn't increase the sense of pain, inflammatory reaction, limb swelling, and total blood loss. It's safe and feasible to remove the drainage tube within 6 to 12 hours after FT primary TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Does the usage of digital chest drainage systems reduce pleural inflammation and volume of pleural effusion following oncologic pulmonary resection?-A prospective randomized trial.

    Science.gov (United States)

    De Waele, Michèle; Agzarian, John; Hanna, Waël C; Schieman, Colin; Finley, Christian J; Macri, Joseph; Schneider, Laura; Schnurr, Terri; Farrokhyar, Forough; Radford, Katherine; Nair, Parameswaran; Shargall, Yaron

    2017-06-01

    Prolonged air leak and high-volume pleural drainage are the most common causes for delays in chest tube removal following lung resection. While digital pleural drainage systems have been successfully used in the management of post-operative air leak, their effect on pleural drainage and inflammation has not been studied before. We hypothesized that digital drainage systems (as compared to traditional analog continuous suction), using intermittent balanced suction, are associated with decreased pleural inflammation and postoperative drainage volumes, thus leading to earlier chest tube removal. One hundred and three [103] patients were enrolled and randomized to either analog (n=50) or digital (n=53) drainage systems following oncologic lung resection. Chest tubes were removed according to standardized, pre-defined protocol. Inflammatory mediators [interleukin-1B (IL-1B), 6, 8, tumour necrosis factor-alpha (TNF-α)] in pleural fluid and serum were measured and analysed. The primary outcome of interest was the difference in total volume of postoperative fluid drainage. Secondary outcome measures included duration of chest tube in-situ, prolonged air-leak incidence, length of hospital stay and the correlation between pleural effusion formation, degree of inflammation and type of drainage system used. There was no significant difference in total amount of fluid drained or length of hospital stay between the two groups. A trend for shorter chest tube duration was found with the digital system when compared to the analog (P=0.055). Comparison of inflammatory mediator levels revealed no significant differences between digital and analog drainage systems. The incidence of prolonged post-operative air leak was significantly higher when using the analog system (9 versus 2 patients; P=0.025). Lobectomy was associated with longer chest tube duration (P=0.001) and increased fluid drainage when compared to sub-lobar resection (Pdigital drainage does not appear to decrease pleural

  17. Intercostal drainage tube or intracardiac drainage tube?

    Directory of Open Access Journals (Sweden)

    N Anitha

    2016-01-01

    Full Text Available Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  18. The role of imaging for the surgeon in primary malignant bone tumors of the chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Rocca, M., E-mail: michele.rocca@ior.it [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Salone, M. [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Galletti, S. [Ultrasound Unit, The Rizzoli Orthopaedic Institute, Bologna (Italy); Balladelli, A. [Laboratory of Experimental Oncology, The Rizzoli Orthopaedic Institute, Bologna (Italy); Vanel, D. [Research in Imaging Musculo Skeletal Tumors, The Rizzoli Orthopaedic Institute, Bologna (Italy); Briccoli, A. [General and Thoracic Surgery, The Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy)

    2013-12-01

    Primary malignant chest wall tumors are rare. The most frequent primary malignant tumor of the chest wall is chondrosarcoma, less common are primary bone tumors belonging to the Ewing Family Bone Tumors (EFBT), or even rarer are osteosarcomas. They represent a challenging clinical entities for surgeons as the treatment of choice for these neoplasms is surgical resection, excluding EFBT which are normally treated by a multidisciplinary approach. Positive margins after surgical procedure are the principal risk factor of local recurrence, therefore to perform adequate surgery a correct preoperative staging is mandatory. Imaging techniques are used for diagnosis, to determine anatomic site and extension, to perform a guided biopsy, for local and general staging, to evaluate chemotherapy response, to detect the presence of a recurrence. This article will focus on the role of imaging in guiding this often difficult surgery and the different technical possibilities adopted in our department to restore the mechanics of the thoracic cage after wide resections.

  19. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer Prevention

    Science.gov (United States)

    ... black women, but have decreased in both groups. Women who have a family history of ovarian cancer and/or certain inherited gene ... ovarian, fallopian tube, and primary peritoneal cancer: Personal history of breast cancer A woman who has had breast cancer has an increased ...

  20. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  1. Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size.

    Science.gov (United States)

    Deák, Zsuzsanna; Maertz, Friedrich; Meurer, Felix; Notohamiprodjo, Susan; Mueck, Fabian; Geyer, Lucas L; Reiser, Maximilian F; Wirth, Stefan

    The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Diagnostic images (lesion conspicuity, 95%-100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.

  2. Management of chest drains: A national survey on surgeons-in-training experience and practice

    Directory of Open Access Journals (Sweden)

    Emeka B Kesieme

    2015-01-01

    Full Text Available Background: Chest tube insertion is a simple and sometimes life-saving procedure performed mainly by surgical residents. However with inadequate knowledge and poor expertise, complications may be life threatening. Objective: We aimed to determine the level of experience and expertise of resident surgeons in performing tube thoracostomy. Methodology: Four tertiary institutions were selected by simple random sampling. A structured questionnaire was administered to 90 residents after obtaining consent. Results: The majority of respondents were between 31 and 35 years. About 10% of respondents have not observed or performed tube thoracostomy while 77.8% of respondents performed tube thoracostomy for thefirst time during residency training. The mean score was 6.2 ± 2.2 and 59.3% of respondents exhibited good experience and practice. Rotation through cardiothoracic surgery had an effect on the score (P = 0.034. About 80.2% always obtained consent while 50.6% always used the blunt technique of insertion. About 61.7% of respondents routinely inserted a chest drain in the Triangle of safety. Only 27.2% of respondents utilized different sizes of chest tubes for different pathologies. Most respondents removed chest drains when the output is <50 mL. Twenty-six respondents (32.1% always monitored air leak before removal of tubes in cases of pneumothorax. Superficial surgical site infection, tube dislodgement, and tube blockage were the most common complications. Conclusion: Many of the surgical resident lack adequate expertise in this lifesaving procedure and they lose the opportunity to learn it as interns. There is a need to stress the need to acquire this skill early, to further educate and evaluate them to avoid complications.

  3. Quality of intensive care chest imaging

    International Nuclear Information System (INIS)

    Adam, G.; Wein, B.; Keulers, P.; Stargardt, A.; Guenther, R.W.

    1989-01-01

    The authors have evaluated the image quality of a stimulable phosphorous plate system in intensive care chest radiography. Four radiologists examined 308 chest radiographs (200 conventional, 108 digital) according to the following criteria: visibility of catheters, tubes (artificial objects), bronchi, central and peripheral vessels, diaphragm, trachea, and retrocardial lung parenchyma. Detectability of these structures was classified as good, poor, or impossible to see. In addition, optical density was measured in the region of liver, heart, and lung. Results were evaluated by Student and υ test

  4. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients: Initial experience with 3rd generation dual-source CT.

    Science.gov (United States)

    Hagelstein, Claudia; Henzler, Thomas; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O; Neff, K Wolfgang; Weis, Meike

    2016-12-01

    Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed to investigate radiation dose and image quality of pediatric chest CT performed at 70 kVp in an anthropomorphic pediatric phantom as well as in clinical patients. An anthropomorphic pediatric phantom, which resembles a one-year-old child in physiognomy, was scanned on the 3 rd generation dual-source CT (DSCT) system at 70 kVp and 80 kVp and a fixed ultra low tube-current of 8 mAs to solely evaluate the impact of lowering tube voltage. After the phantom measurements, 18 pediatric patients (mean 29.5 months; range 1-91 months; 21 examinations) underwent 3.2 high-pitch chest CT on the same DSCT system at 70 kVp tube voltage without any sedation. Radiation dose and presence of motion artifacts was compared to a retrospectively identified patient cohort examined at 80 kVp on a 16-slice single-source-CT (SSCT; n=15; 14/15 with sedation; mean 30.7 months; range 0-96 months; pitch=1.5) or on a 2 nd generation DSCT without any sedation (n=6; mean 32.8 months; range 4-61 months; pitch=3.2). Radiation dose in the phantom scans was reduced by approximately 40% when using a tube voltage of 70 kVp instead of 80 kVp. In the pediatric patient group examined at 70 kVp age-specific effective dose (ED; mean 0.5±0.2 mSv) was significantly lower when compared to the retrospective cohort scanned at 80 kVp on the 16-slice-SSCT (mean ED: 1.0±0.3 mSv; pCT examinations showed any motion artifacts whereas 13/15 examinations of the retrospective patient cohort scanned at 80 kVp with a pitch of 1.5 showed motion artifacts. 3.2 high-pitch chest CT performed with 70 kVp significantly reduces radiation dose when compared to 80 kVp while at the same time provides good image quality without any motion artifacts

  5. What is the yield of routine chest radiography following tube thoracostomy for trauma?

    Science.gov (United States)

    Kong, Victor Y; Oosthuizen, George V; Clarke, Damian L

    2015-01-01

    Routine chest radiography (CXR) following tube thoracostomy (TT) is a standard practice in most trauma centres worldwide. Evidence supporting this routine practice is lacking and the actual yield is unknown. We performed a retrospective review of 1042 patients over a 4-year period who had a routine post-insertion CXR performed in accordance with current ATLS® recommendations. A total 1042 TTs were performed on 1004 patients. Ninety-one per cent of patients (913/1004) were males, and the median age for all patients was 24 years. Seventy-five per cent of all injuries (756/1004) were from penetrating trauma, and the remaining 25% (248/1004) were from blunt. The initial pathologies requiring TT were: haemopneumothorax: 34% (339/1042), haemothroax: 31% (314/1042), simple pneumothorax: 25% (256/1042), tension pneumothorax: 8% (77/1042) and open pneumothorax: 5% (54/1042). One hundred and three patients had TTs performed on clinical grounds alone without a pre-insertion CXR [Group A]. One hundred and ninety-one patients had a pre-insertion CXR but had persistent clinical concerns following insertion [Group B]. Seven hundred and ten patients had pre-insertion CXR but no clinical concerns following insertion [Group C]. Overall, 15% (152/1004) [9 from Group A, 111 from Group B and 32 from Group C] of all patients had their clinical management influenced as a direct result of the post-insertion CXR. Despite the widely accepted practice of routine CXR following tube thoracostomy, the yield is relatively low. In many cases, good clinical examination post tube insertion will provide warnings as to whether problems are likely to result. However, in the more rural setting, and in resource challenged environments, there is a relatively high yield from the CXR, which alters management. Further prospective studies are needed to establish or refute the role of the existing ATLS® guidelines in these specific environments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. ORIGINAL ARTICLES Complications of tube thoracostomy for chest ...

    African Journals Online (AJOL)

    2009-02-01

    Feb 1, 2009 ... Intercostal chest drains (ICDs) are commonly used in South. African emergency centres (ECs), with ... blunt dissection of the muscles and pleura (without trocar) for inserting ICDs. Because of increasing ... drain ward; 24 patients were identified with 26 complications relating to the insertion and positioning of ...

  7. Assessment of chest impedance in relation to phonocardiography

    DEFF Research Database (Denmark)

    Zimmermann, Niels Henrik; Møller, Henrik; Hammershøi, Dorte

    2010-01-01

    the surface of the skin to the transducer. If the impedance of the skin is known, it may be possible to optimize the transducer to achieve an improved signal for a certain frequency range, while attenuating disturbing noise. Further, from a classical stethoscope it is known, that the sound picked up...... by the stethoscope can be influenced by changing the pressure on the chest piece of the stethoscope. A high pressure will stretch the skin similar to a drum skin, and attenuate lower frequencies, while lighter pressure will broaden the frequency range. By using an impedance tube (also known as standing wave tube......), it is possible to measure the impedance of the surface of the skin and at the same time investigate the influence of different pressures and diameters of a transducer. The impedance tube is made specifically with the purpose of measuring chest impedances in the frequency range from 50 Hz to 5 kHz. An MLS...

  8. Combining automatic tube current modulation with adaptive statistical iterative reconstruction for low-dose chest CT screening.

    Directory of Open Access Journals (Sweden)

    Jiang-Hong Chen

    Full Text Available To reduce radiation dose while maintaining image quality in low-dose chest computed tomography (CT by combining adaptive statistical iterative reconstruction (ASIR and automatic tube current modulation (ATCM.Patients undergoing cancer screening (n = 200 were subjected to 64-slice multidetector chest CT scanning with ASIR and ATCM. Patients were divided into groups 1, 2, 3, and 4 (n = 50 each, with a noise index (NI of 15, 20, 30, and 40, respectively. Each image set was reconstructed with 4 ASIR levels (0% ASIR, 30% ASIR, 50% ASIR, and 80% ASIR in each group. Two radiologists assessed subjective image noise, image artifacts, and visibility of the anatomical structures. Objective image noise and signal-to-noise ratio (SNR were measured, and effective dose (ED was recorded.Increased NI was associated with increased subjective and objective image noise results (P<0.001, and SNR decreased with increasing NI (P<0.001. These values improved with increased ASIR levels (P<0.001. Images from all 4 groups were clinically diagnosable. Images with NI = 30 and 50% ASIR had average subjective image noise scores and nearly average anatomical structure visibility scores, with a mean objective image noise of 23.42 HU. The EDs for groups 1, 2, 3 and 4 were 2.79 ± 1.17, 1.69 ± 0.59, 0.74 ± 0.29, and 0.37 ± 0.22 mSv, respectively. Compared to group 1 (NI = 15, the ED reductions were 39.43%, 73.48%, and 86.74% for groups 2, 3, and 4, respectively.Using NI = 30 with 50% ASIR in the chest CT protocol, we obtained average or above-average image quality but a reduced ED.

  9. Optimal chest drain size: the rise of the small-bore pleural catheter.

    Science.gov (United States)

    Fysh, Edward T H; Smith, Nicola A; Lee, Y C Gary

    2010-12-01

    Drainage of the pleural space is not a modern concept, but the optimal size of chest drains to use remains debated. Conventional teaching advocates blunt dissection and large-bore tubes; but in recent years, small-bore catheters have gained popularity. In the absence of high-quality randomized data, this review summarizes the available literature on the choice of chest drains. The objective data supporting the use of large-bore tubes is scarce in most pleural diseases. Increasing evidence shows that small-bore catheters induce less pain and are of comparable efficacy to large-bore tubes, including in the management of pleural infection, malignant effusion, and pneumothoraces. The onus now is on those who favor large tubes to produce clinical data to justify the more invasive approach. © Thieme Medical Publishers.

  10. Lessons from a large trauma center: impact of blunt chest trauma in polytrauma patients-still a relevant problem?

    Science.gov (United States)

    Chrysou, Konstantina; Halat, Gabriel; Hoksch, Beatrix; Schmid, Ralph A; Kocher, Gregor J

    2017-04-20

    Thoracic trauma is the third most common cause of death after abdominal injury and head trauma in polytrauma patients. The purpose of this study was to investigate epidemiological data, treatment and outcome of polytrauma patients with blunt chest trauma in order to help improve management, prevent complications and decrease polytrauma patients' mortality. In this retrospective study we included all polytrauma patients with blunt chest trauma admitted to our tertiary care center emergency department for a 2-year period, from June 2012 until May 2014. Data collection included details of treatment and outcome. Patients with chest trauma and Injury Severity Score (ISS) ≥18 and Abbreviated Injury Scale (AIS) >2 in more than one body region were included. A total of 110 polytrauma patients with blunt chest injury were evaluated. 82 of them were males and median age was 48.5 years. Car accidents, falls from a height and motorbike accidents were the most common causes (>75%) for blunt chest trauma. Rib fractures, pneumothorax and pulmonary contusion were the most common chest injuries. Most patients (64.5%) sustained a serious chest injury (AIS thorax 3), 19.1% a severe chest injury (AIS thorax 4) and 15.5% a moderate chest injury (AIS thorax 2). 90% of patients with blunt chest trauma were treated conservatively. Chest tube insertion was indicated in 54.5% of patients. The need for chest tube was significantly higher among the AIS thorax 4 group in comparison to the AIS groups 3 and 2 (p < 0.001). Also, admission to the ICU was directly related to the severity of the AIS thorax (p < 0.001). The severity of chest trauma did not correlate with ICU length of stay, intubation days, complications or mortality. Although 84.5% of patients suffered from serious or even severe chest injury, neither in the conservative nor in the surgically treated group a significant impact of injury severity on ICU stay, intubation days, complications or mortality was observed. AIS

  11. Investigation of the dosimetry of chest tomosynthesis

    Science.gov (United States)

    Svalkvist, Angelica; Zachrisson, Sara; Månsson, Lars Gunnar; Båth, Magnus

    2009-02-01

    Chest tomosynthesis has recently been introduced to healthcare as a low-dose alternative to CT or as a tool for improved diagnostics in chest radiography with only a modest increase in radiation dose to the patient. However, no detailed description of the dosimetry for this type of examination has been presented. The aim of this work was therefore to investigate the dosimetry of chest tomosynthesis. The chest tomosynthesis examination was assumed to be performed using a stationary detector and a vertically moving x-ray tube, exposing the patient from different angles. The Monte Carlo based computer software PCXMC was used to determine the effective dose delivered to a standard-sized patient from various angles using different assumptions of the distribution of the effective dose over the different projections. The obtained conversion factors between input dose measures and effective dose for chest tomosynthesis for different angular intervals were then compared with the horizontal projection. The results indicate that the error introduced by using conversion factors for the PA projection in chest radiography for estimating the effective dose of chest tomosynthesis is small for normally sized patients, especially if a conversion factor between KAP and effective dose is used.

  12. MDCT quantification is the dominant parameter in decision–making regarding chest tube drainage for stable patients with traumatic pneumothorax

    Science.gov (United States)

    Cai, Wenli; Lee, June-Goo; Fikry, Karim; Yoshida, Hiroyuki; Novelline, Robert; de Moya, Marc

    2013-01-01

    It is commonly believed that the size of a pneumothorax is an important determinant of treatment decision, in particular regarding whether chest tube drainage (CTD) is required. However, the volumetric quantification of pneumothoraces has not routinely been performed in clinics. In this paper, we introduced an automated computer-aided volumetry (CAV) scheme for quantification of volume of pneumothoraces in chest multi-detect CT (MDCT) images. Moreover, we investigated the impact of accurate volume of pneumothoraces in the improvement of the performance in decision-making regarding CTD in the management of traumatic pneumothoraces. For this purpose, an occurrence frequency map was calculated for quantitative analysis of the importance of each clinical parameter in the decision-making regarding CTD by a computer simulation of decision-making using a genetic algorithm (GA) and a support vector machine (SVM). A total of 14 clinical parameters, including volume of pneumothorax calculated by our CAV scheme, was collected as parameters available for decision-making. The results showed that volume was the dominant parameter in decision-making regarding CTD, with an occurrence frequency value of 1.00. The results also indicated that the inclusion of volume provided the best performance that was statistically significant compared to the other tests in which volume was excluded from the clinical parameters. This study provides the scientific evidence for the application of CAV scheme in MDCT volumetric quantification of pneumothoraces in the management of clinically stable chest trauma patients with traumatic pneumothorax. PMID:22560899

  13. Digital radiography of the chest: state of the art

    International Nuclear Information System (INIS)

    Souto, M.; Malagari, K.S.; Tucker, D.; Tahoces, P.G.; Correa, J.; Benakis, V.S.; Roussos, C.; Strigaris, K.A.; Vidal, J.J.; Barnes, G.T.; Fraser, R.G.

    1994-01-01

    Digital image acquisition possesses a number of advantages over conventional systems in radiographic examination of the chest, the most important of which is its greater dynamic range. In addition, once digital images are acquired, they can be processed by computer in ways that cannot be rivalled by conventional analog techniques. Finally, digital images can be stored, retrieved and transmitted to local or remote sites. Here the status of the different digital systems employed in chest radiology and commonly used image processing techniques are reviewed. Also discussed are the current clinical applications of integrating digital chest radiography with a picture archiving and communication system (PACS) along with the difficulties typically encountered. Studies with a variety of digital techniques have been carried out on several fronts. Computed radiography based on photostimulable phosphor (CR) has replaced screen-film imaging in certain applications (i.e. bedside imaging). However, CR has limitations, namely its poor X-ray utilisation efficiency at high X-ray tube voltages and sensitivity to scatter; therefore, it is not ideal for all applications. Recently, a dedicated digital chest unit with excellent X-ray utilisation efficiency at high X-ray tube potentials has been introduced. On the basis of the state-of-the-art capabilities and research during the past decade, recommendations are made regarding the most desirable equipment specifications for dedicated and bedside digital chest radiography. (orig.)

  14. Role of computed tomography in blunt chest trauma

    International Nuclear Information System (INIS)

    Cho, Jae Hyun; Kim, Sang Jin; Lee, Chan Wha; Kim, Hae Kyoon

    1994-01-01

    In patient with blunt trauma of chest, supine AP x-ray cannot differentiate the lung contusion, laceration, atelectasis, and hemothorax definitely. Therefore, computed tomographic evaluation is needed for accurate evaluation of the injuries. In our knowledge, there are few reports about CT findings of blunt chest trauma, in our country, therefore we tried to fluid the characteristic CT findings in patients with blunt trauma. We analyzed the plain x-ray and CT image of 4 patients with blunt chest trauma. Location and morphology of lung parenchymal contusion and laceration, hemopneumothorax, chest wall injuries and location of chest tube. Lung parenchymal contusion was noted in 53 segments., of 16 patients infiltration(n=27 segment), and multiple nodular pattern was noted in 15 segment, pattern of consolidation along the lung periphery was seen in 11 segment. Laceration was noted in 18 lesion and most commonly located in paravertebral area(b=8). CT scan of chest in patient with blunt chest trauma, provides accurate information of the pattern of injuries, and localization, therefore, should be performed as possible

  15. Single-incision video-assisted thoracoscopic evaluation and emergent surgery for severe lung and chest wall injury after thoracic trauma in a water park.

    Science.gov (United States)

    Sesma, Julio; Alvarez, Melodie; Lirio, Francisco; Galvez, Carlos; Galiana, Maria; Baschwitz, Benno; Fornes, Francisca; Bolufer, Sergio

    2017-08-01

    Thoracic trauma is a challenging situation with potential severe chest wall and intrathoracic organ injuries. We present a case of emergent surgery in a 23-year-old man with hemorrhagic shock due to massive lung and chest wall injury after thoracic trauma in a water slide. We performed a SI-VATS approach in order to define intrathoracic and chest wall injuries, and once checked the extension of the chest wall injury, we added a middle size thoracotomy just over the affected area in order to stabilize rib fractures with Judet plates, that had caused massive laceration in left lower lobe (LLL) and injured the pericardium causing myocardical tear. After checking bronchial and vascular viability of LLL we suggested a lung parenchyma preserving technique with PTFE protected pulmonary primary suture in order to avoid a lobectomy. Chest tubes were removed on 3 rd postoperative day and patient was discharged on 14 th postoperative day. He has already recovered his normal activity 6 months after surgery.

  16. Structural integrity assessment of steam generator tubes deteriorated through primary water stress corrosion cracking in transition region of tube expansion

    International Nuclear Information System (INIS)

    Silveira, Helvecio Carlos Klinke da

    2002-01-01

    In PWR plants, steam generator tube degradation has been one of the most important economical concerns, besides causing operational safety problems. In this work, a survey of steam generator tube degradation modes is done. Degradation mechanisms and influence factors are introduced and discussed. The importance of stress corrosion cracking, especially in transition region of tube expansion zone, is underlined. The actual steam generator tube plugging criteria are conservative. Proposed alternative criteria are introduced and discussed. Distinction is done to structural integrity assessment of defective tubes. Real data of tube defect indications of axial cracks in expansion transition zone due to primary water stress corrosion cracking are used in analysis. Results allow discussing application aspects of deterministic and probabilistic criteria on structural integrity assessment of tubes with defect indications. Applied models are specifics, but the application of concept may be extended to other steam generator tube degradation modes. (author)

  17. Combustor with two stage primary fuel tube with concentric members and flow regulating

    Science.gov (United States)

    Parker, David Marchant; Whidden, Graydon Lane; Zolyomi, Wendel

    1999-01-01

    A combustor for a gas turbine having a centrally located fuel nozzle and inner, middle and outer concentric cylindrical liners, the inner liner enclosing a primary combustion zone. The combustor has an air inlet that forms two passages for pre-mixing primary fuel and air to be supplied to the primary combustion zone. Each of the pre-mixing passages has a circumferential array of swirl vanes. A plurality of primary fuel tube assemblies extend through both pre-mixing passages, with each primary fuel tube assembly located between a pair of swirl vanes. Each primary fuel tube assembly is comprised of two tubular members. The first member supplies fuel to the first pre-mixing passage, while the second member, which extends through the first member, supplies fuel to the second pre-mixing passage. An annular fuel manifold is divided into first and second chambers by a circumferentially extending baffle. The proximal end of the first member is attached to the manifold itself while the proximal end of the second member is attached to the baffle. The distal end of the first member is attached directly to the second member at around its mid-point. The inlets of the first and second members are in flow communication with the first and second manifold chambers, respectively. Control valves separately regulate the flow of fuel to the two chambers and, therefore, to the two members of the fuel tube assemblies, thereby allowing the flow of fuel to the first and second pre-mixing passages to be separately controlled.

  18. A Peer-Reviewed Instructional Video is as Effective as a Standard Recorded Didactic Lecture in Medical Trainees Performing Chest Tube Insertion: A Randomized Control Trial.

    Science.gov (United States)

    Saun, Tomas J; Odorizzi, Scott; Yeung, Celine; Johnson, Marjorie; Bandiera, Glen; Dev, Shelly P

    Online medical education resources are becoming an increasingly used modality and many studies have demonstrated their efficacy in procedural instruction. This study sought to determine whether a standardized online procedural video is as effective as a standard recorded didactic teaching session for chest tube insertion. A randomized control trial was conducted. Participants were taught how to insert a chest tube with either a recorded didactic teaching session, or a New England Journal of Medicine (NEJM) video. Participants filled out a questionnaire before and after performing the procedure on a cadaver, which was filmed and assessed by 2 blinded evaluators using a standardized tool. Western University, London, Ontario. Level of clinical care: institutional. A total of 30 fourth-year medical students from 2 graduating classes at the Schulich School of Medicine & Dentistry were screened for eligibility. Two students did not complete the study and were excluded. There were 13 students in the NEJM group, and 15 students in the didactic group. The NEJM group׳s average score was 45.2% (±9.56) on the prequestionnaire, 67.7% (±12.9) for the procedure, and 60.1% (±7.65) on the postquestionnaire. The didactic group׳s average score was 42.8% (±10.9) on the prequestionnaire, 73.7% (±9.90) for the procedure, and 46.5% (±7.46) on the postquestionnaire. There was no difference between the groups on the prequestionnaire (Δ + 2.4%; 95% CI: -5.16 to 9.99), or the procedure (Δ -6.0%; 95% CI: -14.6 to 2.65). The NEJM group had better scores on the postquestionnaire (Δ + 11.15%; 95% CI: 3.74-18.6). The NEJM video was as effective as video-recorded didactic training for teaching the knowledge and technical skills essential for chest tube insertion. Participants expressed high satisfaction with this modality. It may prove to be a helpful adjunct to standard instruction on the topic. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc

  19. Patient dosimetry during chest radiography

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Kosutic, D.; Markovic, S.

    2004-01-01

    Reasons for the variation in patient doses from chest radiography procedure were investigated by assessing entrance skin doses from kerma-area product measurements. Data were collected from seven x-ray tubes in five hospitals involving 259 adult patients. The third quartile value was 0.81 mGy compared to general reference level of 0.30 mGy. The applied tube potential was main contributor to patient dose variation. If department use at least 90 k Vp, the mean entrance surface dose would be reduced ut to factor six. Modification of departmental procedure is correct approach for dose reduction in diagnostic radiology. (author) [sr

  20. Complications following blunt and penetrating injuries in 216 victims of chest trauma requiring tube thoracostomy.

    Science.gov (United States)

    Helling, T S; Gyles, N R; Eisenstein, C L; Soracco, C A

    1989-10-01

    Tube thoracostomy (TT) is required in the treatment of many blunt and penetrating injuries of the chest. In addition to complications from the injuries, TT may contribute to morbidity by introducing microorganisms into the pleural space or by incomplete lung expansion and evacuation of pleural blood. We have attempted to assess the impact of TT following penetrating and blunt thoracic trauma by examining a consecutive series of 216 patients seen at two urban trauma centers with such injuries who required TT over a 30-month period. Ninety-four patients suffered blunt chest trauma; 122 patients were victims of penetrating wounds. Patients with blunt injuries had longer ventilator requirements (12.6 +/- 14 days vs. 3.7 +/- 7.1 days, p = 0.003), longer intensive care stays (12.2 +/- 12.5 days vs. 4.1 +/- 7.5 days, p = 0.001), and longer periods of TT, (6.5 +/- 4.9 days vs. 5.2 +/- 4.5 days, p = 0.018). Empyema occurred in six patients (3%). Residual hemothorax was found in 39 patients (18%), seven of whom required decortication. Recurrent pneumothorax developed in 51 patients (24%) and ten required repeat TT. Complications occurred in 78 patients (36%). Patients with blunt trauma experienced more complications (44%) than those with penetrating wounds (30%) (p = 0.04). However, only seven of 13 patients developing empyema or requiring decortication had blunt trauma. Despite longer requirements for mechanical ventilation, intensive care, and intubation, victims of blunt trauma seemed to have effective drainage of their pleural space by TT without increased risk of infectious complications.

  1. Reverse airflow in certain chest drains may be misinterpreted as prolonged air leakage

    DEFF Research Database (Denmark)

    Stouby, Anna; Neckelmann, Kirsten; Licht, Peter B

    2011-01-01

    Prolonged air leakage is common after lung resection. We observed that during deep inspiration some patients were able to empty the water-seal of commercial chest drainage systems and retract air back into the chest tube, which subsequently escaped during the following expiration, mimicking "true...

  2. A Case of Spontaneously Resolved Bilateral Primary Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Hasan Kahraman

    2014-03-01

    Full Text Available A condition of intrapleural air-space accumulation in individuals without any history of trauma or lung disease is called as primary spontaneous pneumothorax (PSP. Sixteen-years-old male patient admitted with complains of chest pain and dyspnea beginning 3 day ago. On physical examination, severity of breath sounds decreased on right side. Chest radiograph was taken and right-sided pneumothorax was detected and tube thoracostomy was inserted. Two months ago the patient referred to a doctor with similar complaints and physical examination and chest radiograph were reported as normal. The radiograph was retrospectively examined and bilateral PSP was detected. We presented the case duo to spontaneous recovery of bilateral PSP is seen very rarely and so contributes data to the literature. In patients admitted to the clinic with chest pain and shortness of breath, pneumothorax should be considered at differential diagnosis.

  3. CT of blunt chest trauma in children

    International Nuclear Information System (INIS)

    Manson, D.; Babyn, P.S.; Palder, S.; Bergmann, K.

    1993-01-01

    While trauma is still the leading cause of death in the pediatric age range, it is surprising how little the CT appearances of pediatric chest injury have been investigated in the literature. We have reviewed the CT findings of blunt chest trauma in 44 children for whom chest CT examinations were requested to investigate the extent of intrathoracic injury. We noted a propensity for pulmonary contusions to be located posteriorly or posteromedially, and for them to be anatomically nonsegmental and crescentic in shape. This is possibly attributable to the relatively compliant anterior chest wall in children. The CT appearances of other major thoracic injuries are described, including pulmonary lacerations, pneumothoraces, malpositioned chest tubes, mediastinal hematomas, aortic injury, tracheobronchial injury, hemopericardium, and spinal injuries with paraspinal fluid collections. Children demonstrating findings incidental to the actual injury yet important to the subsequent therapy are also presented. We conclude that, in the event of clinically significant blunt chest trauma, the single supine chest examination in the trauma room is insufficient to adequately identify the extent of intrathoracic injury. With the exception of concern for aortic injury for which aortography is indicated, a dynamically enhanced CT scan of the thorax should be performed as clinically significant findings may result in altered therapy. (orig.)

  4. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    Energy Technology Data Exchange (ETDEWEB)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H. [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH{sub T} was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle.

  5. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    International Nuclear Information System (INIS)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H.

    2016-01-01

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH_T was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle

  6. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures.

    Science.gov (United States)

    Chapman, Brandon C; Overbey, Douglas M; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T; French, Andrew; Johnson, Jeffrey L; Burlew, Clay C; Barnett, Carlton; Moore, Ernest E; Pieracci, Fredric M

    2016-12-01

    Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Retrospective cohort study of blunt trauma patients with rib fractures at a level I trauma center that had both a CXR and a CT chest. The CT finding of ≥ 3 additional fractures in patients with ≤ 3 rib fractures on CXR was considered clinically meaningful. Student's t-test and chi-square analysis were used for comparison. We identified 499 patients with rib fractures: 93 (18.6%) had CXR only, 7 (1.4%) had chest CT only, and 399 (79.9%) had both CXR and chest CT. Among these 399 patients, a total of 1,969 rib fractures were identified: 1,467 (74.5%) were missed by CXR. The median number of additional fractures identified by CT was 3 (range, 4 - 15). Of 212 (53.1%) patients with a clinically meaningful increase in the number of fractures, 68 patients underwent one or more clinical interventions: 36 SICU admissions, 20 pain catheter placements, 23 epidural placements, and 3 SSRF. Additionally, 70 patients had a chest tube placed for retained hemothorax or occult pneumothorax. Overall, 138 patients (34.5%) had a change in clinical management based upon CT chest. The chest X-ray missed ~75% of rib fractures seen on chest CT. Although patients with a clinical meaningful increase in the number of rib fractures were more likely to be admitted to the intensive care unit, there was no associated improvement in pulmonary outcomes.

  7. Ultra-high pitch chest computed tomography at 70 kVp tube voltage in an anthropomorphic pediatric phantom and non-sedated pediatric patients. Initial experience with 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Hagelstein, Claudia; Henzler, Thomas; Haubenreisser, Holger; Meyer, Mathias; Sudarski, Sonja; Schoenberg, Stefan O.; Neff, K. Wolfgang; Weis, Meike [Univ. Medical Center Mannheim (Germany). Inst. of Clinical Radiology and Nuclear Medicine

    2016-07-01

    Minimizing radiation dose while at the same time preserving image quality is of particular importance in pediatric chest CT. Very recently, CT imaging with a tube voltage of 70 kVp has become clinically available. However, image noise is inversely proportional to the tube voltage. We aimed to investigate radiation dose and image quality of pediatric chest CT performed at 70 kVp in an anthropomorphic pediatric phantom as well as in clinical patients. An anthropomorphic pediatric phantom, which resembles a one-year-old child in physiognomy, was scanned on the 3{sup rd} generation dual-source CT (DSCT) system at 70 kVp and 80 kVp and a fixed ultra low tube-current of 8 mAs to solely evaluate the impact of lowering tube voltage. After the phantom measurements, 18 pediatric patients (mean 29.5 months; range 1-91 months; 21 examinations) underwent 3.2 high-pitch chest CT on the same DSCT system at 70 kVp tube voltage without any sedation. Radiation dose and presence of motion artifacts was compared to a retrospectively identified patient cohort examined at 80 kVp on a 16-slice single-source-CT (SSCT; n = 15; 14/15 with sedation; mean 30.7 months; range 0-96 months; pitch = 1.5) or on a 2{sup nd} generation DSCT without any sedation (n = 6; mean 32.8 months; range 4-61 months; pitch = 3.2). Radiation dose in the phantom scans was reduced by approximately 40% when using a tube voltage of 70 kVp instead of 80 kVp. In the pediatric patient group examined at 70 kVp age-specific effective dose (ED; mean 0.5 ± 0.2 mSv) was significantly lower when compared to the retrospective cohort scanned at 80 kVp on the 16-slice-SSCT (mean ED: 1.0 ± 0.3 mSv; p < 0.0001) and also considerably lower when compared to the cohort scanned at 80 kVp on the 2{sup nd} generation DSCT (mean ED: 0.9 ± 0.5 mSv). None of the prospective, sedation-free CT examinations showed any motion artifacts whereas 13/15 examinations of the retrospective patient cohort scanned at 80 kVp with a pitch of 1

  8. MDCT quantification is the dominant parameter in decision-making regarding chest tube drainage for stable patients with traumatic pneumothorax.

    Science.gov (United States)

    Cai, Wenli; Lee, June-Goo; Fikry, Karim; Yoshida, Hiroyuki; Novelline, Robert; de Moya, Marc

    2012-07-01

    It is commonly believed that the size of a pneumothorax is an important determinant of treatment decision, in particular regarding whether chest tube drainage (CTD) is required. However, the volumetric quantification of pneumothoraces has not routinely been performed in clinics. In this paper, we introduced an automated computer-aided volumetry (CAV) scheme for quantification of volume of pneumothoraces in chest multi-detect CT (MDCT) images. Moreover, we investigated the impact of accurate volume of pneumothoraces in the improvement of the performance in decision-making regarding CTD in the management of traumatic pneumothoraces. For this purpose, an occurrence frequency map was calculated for quantitative analysis of the importance of each clinical parameter in the decision-making regarding CTD by a computer simulation of decision-making using a genetic algorithm (GA) and a support vector machine (SVM). A total of 14 clinical parameters, including volume of pneumothorax calculated by our CAV scheme, was collected as parameters available for decision-making. The results showed that volume was the dominant parameter in decision-making regarding CTD, with an occurrence frequency value of 1.00. The results also indicated that the inclusion of volume provided the best performance that was statistically significant compared to the other tests in which volume was excluded from the clinical parameters. This study provides the scientific evidence for the application of CAV scheme in MDCT volumetric quantification of pneumothoraces in the management of clinically stable chest trauma patients with traumatic pneumothorax. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Chest wall syndrome among primary care patients: a cohort study

    Directory of Open Access Journals (Sweden)

    Verdon François

    2007-09-01

    Full Text Available Abstract Background The epidemiology of chest pain differs strongly between outpatient and emergency settings. In general practice, the most frequent cause is the chest wall pain. However, there is a lack of information about the characteristics of this syndrome. The aims of the study are to describe the clinical aspects of chest wall syndrome (CWS. Methods Prospective, observational, cohort study of patients attending 58 private practices over a five-week period from March to May 2001 with undifferentiated chest pain. During a one-year follow-up, questionnaires including detailed history and physical exam, were filled out at initial consultation, 3 and 12 months. The outcomes were: clinical characteristics associated with the CWS diagnosis and clinical evolution of the syndrome. Results Among 24 620 consultations, we observed 672 cases of chest pain and 300 (44.6% patients had a diagnosis of chest wall syndrome. It affected all ages with a sex ratio of 1:1. History and sensibility to palpation were the keys for diagnosis. Pain was generally moderate, well localised, continuous or intermittent over a number of hours to days or weeks, and amplified by position or movement. The pain however, may be acute. Eighty-eight patients were affected at several painful sites, and 210 patients at a single site, most frequently in the midline or a left-sided site. Pain was a cause of anxiety and cardiac concern, especially when acute. CWS coexisted with coronary disease in 19 and neoplasm in 6. Outcome at one year was favourable even though CWS recurred in half of patients. Conclusion CWS is common and benign, but leads to anxiety and recurred frequently. Because the majority of chest wall pain is left-sided, the possibility of coexistence with coronary disease needs careful consideration.

  10. Chest wall syndrome among primary care patients: a cohort study.

    Science.gov (United States)

    Verdon, François; Burnand, Bernard; Herzig, Lilli; Junod, Michel; Pécoud, Alain; Favrat, Bernard

    2007-09-12

    The epidemiology of chest pain differs strongly between outpatient and emergency settings. In general practice, the most frequent cause is the chest wall pain. However, there is a lack of information about the characteristics of this syndrome. The aims of the study are to describe the clinical aspects of chest wall syndrome (CWS). Prospective, observational, cohort study of patients attending 58 private practices over a five-week period from March to May 2001 with undifferentiated chest pain. During a one-year follow-up, questionnaires including detailed history and physical exam, were filled out at initial consultation, 3 and 12 months. The outcomes were: clinical characteristics associated with the CWS diagnosis and clinical evolution of the syndrome. Among 24 620 consultations, we observed 672 cases of chest pain and 300 (44.6%) patients had a diagnosis of chest wall syndrome. It affected all ages with a sex ratio of 1:1. History and sensibility to palpation were the keys for diagnosis. Pain was generally moderate, well localised, continuous or intermittent over a number of hours to days or weeks, and amplified by position or movement. The pain however, may be acute. Eighty-eight patients were affected at several painful sites, and 210 patients at a single site, most frequently in the midline or a left-sided site. Pain was a cause of anxiety and cardiac concern, especially when acute. CWS coexisted with coronary disease in 19 and neoplasm in 6. Outcome at one year was favourable even though CWS recurred in half of patients. CWS is common and benign, but leads to anxiety and recurred frequently. Because the majority of chest wall pain is left-sided, the possibility of coexistence with coronary disease needs careful consideration.

  11. Chest wall syndrome among primary care patients: a cohort study

    Science.gov (United States)

    Verdon, François; Burnand, Bernard; Herzig, Lilli; Junod, Michel; Pécoud, Alain; Favrat, Bernard

    2007-01-01

    Background The epidemiology of chest pain differs strongly between outpatient and emergency settings. In general practice, the most frequent cause is the chest wall pain. However, there is a lack of information about the characteristics of this syndrome. The aims of the study are to describe the clinical aspects of chest wall syndrome (CWS). Methods Prospective, observational, cohort study of patients attending 58 private practices over a five-week period from March to May 2001 with undifferentiated chest pain. During a one-year follow-up, questionnaires including detailed history and physical exam, were filled out at initial consultation, 3 and 12 months. The outcomes were: clinical characteristics associated with the CWS diagnosis and clinical evolution of the syndrome. Results Among 24 620 consultations, we observed 672 cases of chest pain and 300 (44.6%) patients had a diagnosis of chest wall syndrome. It affected all ages with a sex ratio of 1:1. History and sensibility to palpation were the keys for diagnosis. Pain was generally moderate, well localised, continuous or intermittent over a number of hours to days or weeks, and amplified by position or movement. The pain however, may be acute. Eighty-eight patients were affected at several painful sites, and 210 patients at a single site, most frequently in the midline or a left-sided site. Pain was a cause of anxiety and cardiac concern, especially when acute. CWS coexisted with coronary disease in 19 and neoplasm in 6. Outcome at one year was favourable even though CWS recurred in half of patients. Conclusion CWS is common and benign, but leads to anxiety and recurred frequently. Because the majority of chest wall pain is left-sided, the possibility of coexistence with coronary disease needs careful consideration. PMID:17850647

  12. [Folic acid: Primary prevention of neural tube defects. Literature Review].

    Science.gov (United States)

    Llamas Centeno, M J; Miguélez Lago, C

    2016-03-01

    Neural tube defects (NTD) are the most common congenital malformations of the nervous system, they have a multifactorial etiology, are caused by exposure to chemical, physical or biological toxic agents, factors deficiency, diabetes, obesity, hyperthermia, genetic alterations and unknown causes. Some of these factors are associated with malnutrition by interfering with the folic acid metabolic pathway, the vitamin responsible for neural tube closure. Its deficit produce anomalies that can cause abortions, stillbirths or newborn serious injuries that cause disability, impaired quality of life and require expensive treatments to try to alleviate in some way the alterations produced in the embryo. Folic acid deficiency is considered the ultimate cause of the production of neural tube defects, it is clear the reduction in the incidence of Espina Bifida after administration of folic acid before conception, this leads us to want to further study the action of folic acid and its application in the primary prevention of neural tube defects. More than 40 countries have made the fortification of flour with folate, achieving encouraging data of decrease in the prevalence of neural tube defects. This paper attempts to make a literature review, which clarify the current situation and future of the prevention of neural tube defects.

  13. Surgical management for the first 48 h following blunt chest trauma: state of the art (excluding vascular injuries).

    Science.gov (United States)

    de Lesquen, Henri; Avaro, Jean-Philippe; Gust, Lucile; Ford, Robert Michael; Beranger, Fabien; Natale, Claudia; Bonnet, Pierre-Mathieu; D'Journo, Xavier-Benoît

    2015-03-01

    This review aims to answer the most common questions in routine surgical practice during the first 48 h of blunt chest trauma (BCT) management. Two authors identified relevant manuscripts published since January 1994 to January 2014. Using preferred reporting items for systematic reviews and meta-analyses statement, they focused on the surgical management of BCT, excluded both child and vascular injuries and selected 80 studies. Tension pneumothorax should be promptly diagnosed and treated by needle decompression closely followed with chest tube insertion (Grade D). All traumatic pneumothoraces are considered for chest tube insertion. However, observation is possible for selected patients with small unilateral pneumothoraces without respiratory disease or need for positive pressure ventilation (Grade C). Symptomatic traumatic haemothoraces or haemothoraces >500 ml should be treated by chest tube insertion (Grade D). Occult pneumothoraces and occult haemothoraces are managed by observation with daily chest X-rays (Grades B and C). Periprocedural antibiotics are used to prevent chest-tube-related infectious complications (Grade B). No sign of life at the initial assessment and cardiopulmonary resuscitation duration >10 min are considered as contraindications of Emergency Department Thoracotomy (Grade C). Damage Control Thoracotomy is performed for either massive air leakage or refractive shock or ongoing bleeding enhanced by chest tube output >1500 ml initially or >200 ml/h for 3 h (Grade D). In the case of haemodynamically stable patients, early video-assisted thoracic surgery is performed for retained haemothoraces (Grade B). Fixation of flail chest can be considered if mechanical ventilation for 48 h is probably required (Grade B). Fixation of sternal fractures is performed for displaced fractures with overlap or comminution, intractable pain or respiratory insufficiency (Grade D). Lung herniation, traumatic diaphragmatic rupture and pericardial rupture are life

  14. Revision of orthovoltage chest wall treatment using Monte Carlo simulations.

    Science.gov (United States)

    Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Mosalaei, A; Hadad, K

    2017-01-01

    Given the high local control rates observed in breast cancer patients undergoing chest wall irradiation by kilovoltage x-rays, we aimed to revisit this treatment modality by accurate calculation of dose distributions using Monte Carlo simulation. The machine components were simulated using the MCNPX code. This model was used to assess the dose distribution of chest wall kilovoltage treatment in different chest wall thicknesses and larger contour or fat patients in standard and mid sternum treatment plans. Assessments were performed at 50 and 100 cm focus surface distance (FSD) and different irradiation angles. In order to evaluate different plans, indices like homogeneity index, conformity index, the average dose of heart, lung, left anterior descending artery (LAD) and percentage target coverage (PTC) were used. Finally, the results were compared with the indices provided by electron therapy which is a more routine treatment of chest wall. These indices in a medium chest wall thickness in standard treatment plan at 50 cm FSD and 15 degrees tube angle was as follows: homogeneity index 2.57, conformity index 7.31, average target dose 27.43 Gy, average dose of heart, lung and LAD, 1.03, 2.08 and 1.60 Gy respectively and PTC 11.19%. Assessments revealed that dose homogeneity in planning target volume (PTV) and conformity between the high dose region and PTV was poor. To improve the treatment indices, the reference point was transferred from the chest wall skin surface to the center of PTV. The indices changed as follows: conformity index 7.31, average target dose 60.19 Gy, the average dose of heart, lung and LAD, 3.57, 6.38 and 5.05 Gy respectively and PTC 55.24%. Coverage index of electron therapy was 89% while it was 22.74% in the old orthovoltage method and also the average dose of the target was about 50 Gy but in the given method it was almost 30 Gy. The results of the treatment study show that the optimized standard and mid sternum treatment for different chest

  15. How to remove a chest drain.

    Science.gov (United States)

    Allibone, Elizabeth

    2015-10-07

    RATIONALE AND KEY POINTS: This article aims to help nurses to undertake the removal of a chest drain in a safe, effective and patient-centred manner. This procedure requires two practitioners. The chest drain will have been inserted aseptically to remove air, blood, fluid or pus from the pleural cavity. ▶ Chest drains may be small or wide bore depending on the underlying condition and clinical setting. They may be secured with a mattress suture and/or an anchor suture. ▶ Chest drains are usually removed under medical instructions when the patient's lung has inflated, the underlying condition has resolved, there is no evidence of respiratory compromise or failure, and their anticoagulation status has been assessed as satisfactory. ▶ Chest drains secured with a mattress suture should be removed by two practitioners. One practitioner is required to remove the tube and the other to tie the mattress suture (if present) and secure the site. REFLECTIVE ACTIVITY: Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. How reading this article will change your practice. 2. How this article could be used to educate patients with chest drains. Subscribers can upload their reflective accounts at: rcni.com/portfolio .

  16. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Shaw, D.J.; Crawshaw, I.; Rimmer, S.D.

    2013-01-01

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV p ) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV p relative to 109 kV p , though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p p . Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique

  17. Chest Radiographic Findings in Primary Pulmonary Tuberculosis: Observations from High School Outbreaks

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Won Jung; Kwon, O Jung; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Jeong, Yeon Joo [Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Kim, Hee Jin; Lew, Woo Jin [Korean Institute of Tuberculosis, Seoul (Korea, Republic of); Cho, En Hi [4Korea Centers for Disease Control and Prevention, Seoul (Korea, Republic of)

    2010-12-15

    To describe the radiographic findings of primary pulmonary tuberculosis (TB) in previously healthy adolescent patients. The Institutional Review Board approved this retrospective study, with a waiver of informed consent from the patients. TB outbreaks occurred in 15 senior high schools and chest radiographs from 58 students with identical strains of TB were analyzed by restriction fragment length polymorphism analysis by two independent observers. Lesions of nodule(s), consolidation, or cavitation in the upper lung zones were classified as typical TB. Mediastinal lymph node enlargement; lesions of nodule(s), consolidation, or cavitation in lower lung zones; or pleural effusion were classified as atypical TB. Inter-observer agreement for the presence of each radiographic finding was examined by kappa statistics. Of 58 patients, three (5%) had normal chest radiographs. Cavitary lesions were present in 25 (45%) of 55 students. Lesions with upper lung zone predominance were observed in 27 (49%) patients, whereas lower lung zone predominance was noted in 18 (33%) patients. The remaining 10 (18%) patients had lesions in both upper and lower lung zones. Pleural effusion was not observed in any patient, nor was the mediastinal lymph node enlargement. Hilar lymph node enlargement was seen in only one (2%) patient. Overall, 37 (67%) students had the typical form of TB, whereas 18 (33%) had TB lesions of the atypical form. The most common radiographic findings in primary pulmonary TB by recent infection in previously healthy adolescents are upper lung lesions, which were thought to be radiographic findings of reactivation pulmonary TB by remote infection

  18. Dose-image quality study in digital chest radiography using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.; Yoriyaz, H.

    2008-01-01

    One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage

  19. General Information About Ovarian, Fallopian Tube, and Primary Peritoneal Cancer

    Science.gov (United States)

    ... black women, but have decreased in both groups. Women who have a family history of ovarian cancer and/or certain inherited gene ... ovarian, fallopian tube, and primary peritoneal cancer: Personal history of breast cancer A woman who has had breast cancer has an increased ...

  20. Radiation dose reduction in chest CT—Review of available options

    International Nuclear Information System (INIS)

    Kubo, Takeshi; Ohno, Yoshiharu; Kauczor, Hans Ulrich; Hatabu, Hiroto

    2014-01-01

    Highlights: • The present status of proliferating CT examinations was presented. • Technical improvements of CT scanners for radiation dose reduction were reviewed. • Advantage and disadvantage of methods for CT radiation dose reduction were discussed. • Evidences for safety of CT radiation dose reduction were reviewed. - Abstract: Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT

  1. Radiation dose reduction in chest CT—Review of available options

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Takeshi, E-mail: tkubo@kuhpkyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Kauczor, Hans Ulrich, E-mail: hu.kauczor@med.uni-heidelberg.de [Diagnostic and Interventional Radiology, University Clinic Heidelberg, Im Neuenheimer Feld 110, D-69120 Heidelberg (Germany); Hatabu, Hiroto, E-mail: hhatabu@partners.org [Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, Boston, MA 02115 (United States)

    2014-10-15

    Highlights: • The present status of proliferating CT examinations was presented. • Technical improvements of CT scanners for radiation dose reduction were reviewed. • Advantage and disadvantage of methods for CT radiation dose reduction were discussed. • Evidences for safety of CT radiation dose reduction were reviewed. - Abstract: Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT.

  2. Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CT

    NARCIS (Netherlands)

    Scholten, Ernst Th.; Jacobs, Colin; van Ginneken, Bram; Willemink, Martin J.; Kuhnigk, Jan-Martin; van Ooijen, Peter M. A.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; de Jong, Pim A.

    OBJECTIVE. The purpose of this study was to investigate a new software program for semiautomatic measurement of the volume and mass of ground-glass nodules (GGNs) in a chest phantom and to investigate the influence of CT scanner, reconstruction filter, tube voltage, and tube current. MATERIALS AND

  3. [A case of group G Streptococcus sepsis, chest wall abscess, and vertebral osteomyelitis mimicking a primary lung cancer with bone metastasis].

    Science.gov (United States)

    Hayashi, Yumeko; Ishii, Yoshiki; Arai, Ryo; Obara, Kazuki; Kamada, Aya; Takizawa, Hidenori; Hase, Isano; Mashio, Kazuki; Yamada, Issei; Takemasa, Akihiro; Sugiyama, Kumiya; Fukushima, Yasutsugu; Fukuda, Takeshi

    2007-01-01

    A 73-year-old woman who had been followed in our department of gynecology because of ovarian cancer since 2002, was admitted with liver dysfunction and complaining of back pain and light precordial chest pain. The chest radiograph on admission revealed a tumor in her left upper lung field, and chest CT revealed a tumor adjacent to the chest wall and mediastinum. FDG-positron emission tomography (PET) showed abnormal uptake in the tumor and Th6/7, and the subaortic lymph nodes. On the basis of these findings, primary lung cancer with bone metastasis was suspected. She had a high grade fever on admission, and blood cultures were positive for group G streptococcus. The treatment with intravenous penicillin was started. Percutaneous biopsy of the tumor in her left chest showed an abscess wall in the chest wall, but no evidence of malignancy. Transbronchial lung biopsy and CT-guided biopsy also showed no malignant cells. Since the tumor decreased in size and back pain improved gradually by only antibiotic treatment, a diagnosis of sepsis of group G streptococcus, chest wall abscess, and vertebral osteomyelitis was made. She was treated with intravenous penicillin for 4 weeks and oral amoxicillin for another 4 weeks. After 60 days of antibiotic treatment, the tumor vanished.

  4. Pulmonary Metastasis from Rectal Cancer on Chest CT Is Correlated with 3T MRI Primary Tumor Location

    International Nuclear Information System (INIS)

    Han, Na Yeon; Kim, Min Ju; Park, Beon Jin; Sung, Deuk Jae; Chung, Kyoo Byung; Oh, Yu Whan

    2011-01-01

    To evaluate the association between the incidence of pulmonary metastasis on chest CT and the location of the primary tumor on rectal MRI. One hundred and nine consecutive patients with rectal adenocarcinoma underwent chest CT and 3T rectal MRI. Two radiologists classified the tumor on MRI as an upper (> 10 cm from the anal verge), mid (5-10 cm), or lower rectal tumor (< 5 cm) by consensus. All chest CT scans were retrospectively reviewed for the presence of metastasis. We used Fisher's exact test to evaluate the correlation between the incidence of pulmonary metastasis with the location of the rectal cancer and the Mantel-Haenszel test to control for local tumor stage. We only included the 60 patients with upper (n = 26) or lower (n = 34) rectal cancer, because of the complicated venous drainage system of the mid rectum. Among these, 9 (15%) showed evidence of pulmonary metastasis on chest CT and almost all (89%, 8/9) patients had lower rectal cancer. The incidence of pulmonary metastasis between the two groups was statistically different (p < 0.05) when local tumor stage was controlled. The incidence of pulmonary metastasis was significantly higher for lower than upper rectal cancers when the T-stage of the tumor was accounted for.

  5. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  6. Chest closure without drainage after open patent ductus arteriosus ligation in Ugandan children: A non blinded randomized controlled trial.

    Science.gov (United States)

    Kebba, Naomi; Mwambu, Tom; Oketcho, Michael; Izudi, Jonathan; Obuku, Ekwaro A

    2016-09-29

    There is clinical equipoise regarding post-operative management of patients with patent ductus arteriosus (PDA) without insertion of a chest drain. This study evaluated post operative outcomes of chest closure with or without a drain following Patent Ductus Arteriosus ligation among childen at Uganda Heart Instritute (UHI). This was an open label randomized controlled trial of 62 children 12 years of age and below diagnosed with patent ductus arteriosus at Mulago National Teaching and Referral Hospital, Uganda. Participants were randomized in the ratio of 1:1 with surgical ligation of patent ductus arteriosus to either thoracotomy closure with a chest tube or without a chest tube. All participants received standard care and were monitored hourly for 24 hours then until hospital discharge. The combined primary endpoint consisted of significant pleural space accumulation of fluid or air, higher oxygen need or infection of the surgical site. Analysis was conducted by multivariable logistic regression analysis at 5 % significance level. We enrolled 62 participants, 46 (74 %) of whom were females. Their median age was 12 months (IQR: 8-36). Participants in the no-drain arm significantly had less post-operative complications compared to the drain arm (Unadjusted odds ratio [uOR]: 0.21, 95 % CI: 0.06-0.73, p = 0.015). This "protective effect" remained without statistical significance in the multivariable regression model (Adjusted odds ratio [aOR]: 0.07, 95 % CI: 0.00-2.50, p = 0.144). Children aged below 6 years with patent ductus arterious can safely and effectively have thoracotomy closure without using a drain in uncomplicated surgical ligation of the PDA. Chest drain was associated with post-operative complications. The trial was registered in the Pan African Clinical Trials registry on 1st/July/2012, retrospectively registered. Identifier number PACTR201207000395469 .

  7. The Interest of Performing "On-Demand Chest X-rays" after Lung Resection by Minimally Invasive Surgery.

    Science.gov (United States)

    Haddad, Laura; Bubenheim, Michael; Bernard, Alain; Melki, Jean; Peillon, Christophe; Baste, Jean-Marc

    2017-10-01

    Background  There is a lack of consensus in hospital centers regarding costly daily routine chest X-rays after lung resection by minimally invasive surgery. Indeed, there is no evidence that performing daily chest X-rays prevents postoperative complications. Our objective was to compare chest X-rays performed on demand when there was clinical suspicion of postoperative complications and chest X-rays performed systematically in daily routine practice. Methods  This prospective single-center study compared 55 patients who had on-demand chest X-rays and patients in the literature who had daily routine chest X-rays. Our primary evaluation criterion was length of hospitalization. Results  The length of hospitalization was 5.3 ± 3.3 days for patients who had on-demand X-rays, compared with 4 to 9.7 days for patients who had daily routine X-rays. Time to chest tube removal (4.34 days), overall complication rate (27.2%), reoperation rate (3.6%), and mortality rate (1.8%) were comparable to those in the literature. On average, our patients only had 1.22 ± 1.8 on-demand X-rays, compared with 3.3 X-rays if daily routine protocol had been applied. Patients with complications had more X-rays (3.4 ± 1.8) than patients without complications (0.4 ± 0.7). Conclusion  On-demand chest X-rays do not seem to delay the diagnosis of postoperative complications or increase morbidity-mortality rates. Performing on-demand chest X-rays could not only simplify surgical practice but also have a positive impact on health care expenses. However, a broader randomized study is warranted to validate this work and ultimately lead to national consensus. Georg Thieme Verlag KG Stuttgart · New York.

  8. Pleural Drainage and its Role in Management of the Isolated Penetrating Chest Injuries During the War Time in Sarajevo, 1992.-1995.

    Directory of Open Access Journals (Sweden)

    Ademir Hadžismajlović

    2007-05-01

    Full Text Available Penetrating chest injuries are the most frequent causes of serious demage and death in wounded indivisuals. In reports from the last wars where wounds caused by high velocity projectiles predominated, thoracotomies were perfomed in about 15% of the wounded individuals, mostly encompassing injuries of the heart and great vessels, accomanied by massive bleeding that could not be resolved by chest tube insertion. This retrospective analysis was performed on the medical records of 477 patients tretaed for isolated penetrating chest injuries in Department of Thoracic Surgery Clinical Center of the University in Sarajevo between april 1992 - june 1995. We analised the ways of their menagement with special view on pleural drainage, indication for this method and results of treatment. 398 (83,4% wounded individuals have been treated with pleural tube inserting as definitive mesaure and for the urgent thoracotomy there were 79 (16,6% patients left. Average hospital treatment in wounded drained patients was 7,68 days. With shrapnels there were 357 (74,84% wounded individuals, and with bullet 120 (25,16% wounded individuals. The complications of plaural tube inserting were - empyema in 34 (7,13% patients and there were no other complications. Chest tube inserting as definitive mesaure was used in 398 (83,44% patients. Chest tube inserting as preoperative measure (urgent thoracotomy was used in 79 (16,56% patients. There were 460 (96,44% healed patients. Death occurred in 17 (3,56% patients.

  9. Pleural drainage and its role in management of the isolated penetrating chest injuries during the war time in Sarajevo, 1992.-1995.

    Science.gov (United States)

    Hadzismajlović, Ademir; Pilav, Alen

    2007-05-01

    Penetrating chest injuries are the most frequent causes of serious demage and death in wounded indivisuals. In reports from the last wars where wounds caused by high velocity projectiles predominated, thoracotomies were perfomed in about 15% of the wounded individuals, mostly encompassing injuries of the heart and great vessels, accomanied by massive bleeding that could not be resolved by chest tube insertion. This retrospective analysis was performed on the medical records of 477 patients tretaed for isolated penetrating chest injuries in Department of Thoracic Surgery Clinical Center of the University in Sarajevo between april 1992 - june 1995. We analised the ways of their menagement with special view on pleural drainage, indication for this method and results of treatment. 398 (83,4%) wounded individuals have been treated with pleural tube inserting as definitive mesaure and for the urgent thoracotomy there were 79 (16,6%) patients left. Average hospital treatment in wounded drained patients was 7,68 days. With shrapnels there were 357 (74,84%) wounded individuals, and with bullet 120 (25,16%) wounded individuals. The complications of plaural tube inserting were - empyema in 34 (7,13%) patients and there were no other complications. Chest tube inserting as definitive mesaure was used in 398 (83,44%) patients. Chest tube inserting as preoperative measure (urgent thoracotomy) was used in 79 (16,56%) patients. There were 460 (96,44%) healed patients. Death occurred in 17 (3,56%) patients.

  10. Glutathione in Preventing Peripheral Neuropathy Caused by Paclitaxel and Carboplatin in Patients With Ovarian Cancer, Fallopian Tube Cancer, and/or Primary Peritoneal Cancer

    Science.gov (United States)

    2017-01-05

    Chemotherapeutic Agent Toxicity; Neuropathy; Neurotoxicity Syndrome; Pain; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  11. Utility of Chest Computed Tomography after a "Normal" Chest Radiograph in Patients with Thoracic Stab Wounds.

    Science.gov (United States)

    Nguyen, Brian M; Plurad, David; Abrishami, Sadaf; Neville, Angela; Putnam, Brant; Kim, Dennis Y

    2015-10-01

    Chest computed tomography (CCT) is used to screen for injuries in hemodynamically stable patients with penetrating injury. We aim to determine the incidence of missed injuries detected on CCT after a negative chest radiograph (CXR) in patients with thoracic stab wounds. A 10-year retrospective review of a Level I trauma center registry was performed on patients with thoracic stab wounds. Patients who were hemodynamically unstable or did not undergo both CXR and CCT were excluded. Patients with a negative CXR were evaluated to determine if additional findings were diagnosed on CCT. Of 386 patients with stab wounds to the chest, 154 (40%) underwent both CXR and CCT. One hundred and fifteen (75%) had a negative screening CXR. CCT identified injuries in 42 patients (37%) that were not seen on CXR. Pneumothorax and/or hemothorax occurred in 40 patients (35%), of which 14 patients underwent tube thoracostomy. Two patients had hemopericardium on CCT and both required operative intervention. Greater than one-third of patients with a normal screening CXR were found to have abnormalities on CCT. Future studies comparing repeat CXR to CCT are required to further define the optimal diagnostic strategy in patients with stab wounds to chest after normal screening CXR.

  12. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  13. Simple aspiration versus intercostal tube drainage for primary spontaneous pneumothorax in adults.

    Science.gov (United States)

    Carson-Chahhoud, Kristin V; Wakai, Abel; van Agteren, Joseph Em; Smith, Brian J; McCabe, Grainne; Brinn, Malcolm P; O'Sullivan, Ronan

    2017-09-07

    For management of pneumothorax that occurs without underlying lung disease, also referred to as primary spontaneous pneumothorax, simple aspiration is technically easier to perform than intercostal tube drainage. In this systematic review, we seek to compare the clinical efficacy and safety of simple aspiration versus intercostal tube drainage for management of primary spontaneous pneumothorax. This review was first published in 2007 and was updated in 2017. To compare the clinical efficacy and safety of simple aspiration versus intercostal tube drainage for management of primary spontaneous pneumothorax. We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 1) in the Cochrane Library; MEDLINE (1966 to January 2017); and Embase (1980 to January 2017). We searched the World Health Organization (WHO) International Clinical Trials Registry for ongoing trials (January 2017). We checked the reference lists of included trials and contacted trial authors. We imposed no language restrictions. We included randomized controlled trials (RCTs) of adults 18 years of age and older with primary spontaneous pneumothorax that compared simple aspiration versus intercostal tube drainage. Two review authors independently selected studies for inclusion, assessed trial quality, and extracted data. We combined studies using the random-effects model. Of 2332 publications obtained through the search strategy, seven studies met the inclusion criteria; one study was ongoing and six studies of 435 participants were eligible for inclusion in the updated review. Data show a significant difference in immediate success rates of procedures favouring tube drainage over simple aspiration for management of primary spontaneous pneumothorax (risk ratio (RR) 0.78, 95% confidence interval (CI) 0.69 to 0.89; 435 participants, 6 studies; moderate-quality evidence). Duration of hospitalization however was significantly less for patients treated by simple aspiration (mean

  14. Chest pain in daily practice: occurrence, causes and management.

    Science.gov (United States)

    Verdon, François; Herzig, Lilli; Burnand, Bernard; Bischoff, Thomas; Pécoud, Alain; Junod, Michel; Mühlemann, Nicole; Favrat, Bernard

    2008-06-14

    We assessed the occurrence and aetiology of chest pain in primary care practice. These features differ between primary and emergency care settings, where most previous studies have been performed. 59 GPs in western Switzerland recorded all consecutive cases presenting with chest pain. Clinical characteristics, laboratory tests and other investigations as well as the diagnoses remaining after 12 months of follow-up were systematically registered. Among 24,620 patients examined during a total duration of 300 weeks of observation, 672 (2.7%) presented with chest pain (52% female, mean age 55 +/- 19(SD)). Most cases, 442 (1.8%), presented new symptoms and in 356 (1.4%) it was the reason for consulting. Over 40 ailments were diagnosed: musculoskeletal chest pain (including chest wall syndrome) (49%), cardiovascular (16%), psychogenic (11%), respiratory (10%), digestive (8%), miscellaneous (2%) and without diagnosis (3%). The three most prevalent diseases were: chest wall syndrome (43%), coronary artery disease (12%) and anxiety (7%). Unstable angina (6), myocardial infarction (4) and pulmonary embolism (2) were uncommon (1.8%). Potentially serious conditions including cardiac, respiratory and neoplasic diseases accounted for 20% of cases. A large number of laboratory tests (42%), referral to a specialist (16%) or hospitalisation (5%) were performed. Twentyfive patients died during follow-up, of which twelve were for a reason directly associated with thoracic pain [cancer (7) and cardiac causes (5)]. Thoracic pain was present in 2.7% of primary care consultations. Chest wall syndrome pain was the main aetiology. Cardio - vascular emergencies were uncommon. However chest pain deserves full consideration because of the occurrence of potentially serious conditions.

  15. Comparison of pulsed fluoroscopy by direct control using a grid-controlled x-ray tube with pulsed fluoroscopy by primary control

    International Nuclear Information System (INIS)

    Chida, Koichi; Zuguchi, Masayuki; Ito, Daisuke; Sato, Kunihiko; Shimura, Hirotaka; Sasaki, Masatoshi

    2001-01-01

    Interventional radiology (IVR) procedures may involve high radiation doses that are potentially harmful to the patient. In IVR procedures, pulsed fluoroscopy can greatly decrease the radiation that the physician and patient receive. There are two types of pulsed fluoroscopy: direct control and primary (indirect) control. The purpose of this study was to compare pulsed fluoroscopy by direct control, using a grid-controlled x-ray tube, with pulsed fluoroscopy using primary control. For both types of pulsed fluoroscopy, we measured the waveforms (x-ray tube voltage, x-ray tube current, and x-ray output) and the relative radiation dose. In addition, we compared the decrease in radiation during pulsed fluoroscopy using a care filter. The studies were performed using a Siemens Bicor Plus x-ray System (direct control) and a Siemens Multistar Plus x-ray System (primary control). Using primary pulse control, a 50% decrease in the x-ray output waveform took approximately 0.5-1.0 msec, or longer with a lower x-ray tube current. Using direct pulse control, a 50% decrease in the x-ray output waveform took approximately 0.1 msec, and was independent of x-ray tube current. The rate of radiation reduction with primary pulse control using the care filter with a lower x-ray tube current had a slope exceeding 10%. Pulsed fluoroscopy by direct control using a grid-controlled x-ray tube permits an optimal radiation dose. To decrease the radiation in primary pulse control, a care filter must be used, particularly with a lower x-ray tube current. (author)

  16. PleurAlert: an augmented chest drainage system with electronic sensing, automated alerts and internet connectivity.

    Science.gov (United States)

    Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T

    2012-01-01

    We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.

  17. How to secure the connection between thoracostomy tube and drainage system?

    Science.gov (United States)

    Li, Ka Ki Pat; Wong, Kit Shing John; Wong, Yau Hang Henry; Cheng, Ka Lok; So, Fung Ling; Lau, Chu Leung; Kam, Chak Wah

    2014-01-01

    Thoracostomy tube insertion is one of the common bedside procedures in emergency medicine and many acute specialties. Dislodgement of thoracostomy tube from the connection tube of chest drainage system is an important problem with potential complications such as contamination, infection and pneumothorax. Besides, mere loosening can also lead to malfunction. It is a common practice to tape the connection of the system. This study aimed to evaluate the materials and methods of connection of chest drain system to minimize drainage dislodgement. We conducted an experimental study to assess the tightness of the connection with various taping materials and methods. We selected three commonly used adhesive materials (3M™ Transpore™ Medical tape, 3M™ Micropore™ Medical tape, 3M™ Soft Cloth Tape on Liner) and three different methods (cross method, straight method, nylon band) to secure the junction between the thoracostomy tube and the bi-conical adaptor in the drainage system. The measured outcome was the weight causing visible loosening of the junction between thoracotomy tube and the adaptor. For each taping material and taping method, 10 trials were performed. The median weight required to disconnect the junction is 26.22 lb for Transpore™, 31.29 lb for Micropore™ and 32.44 lb for Soft Cloth Tape on Liner. A smaller force was required to disconnect if Transpore™ is used (Ptube to the chest drainage system. Transpore™ is not a recommended material for thoracostomy tube taping.

  18. Influence of chest radiotherapy in frequency and patterns of chest relapse in disseminated small cell lung carcinoma

    International Nuclear Information System (INIS)

    Mira, J.G.; Livingston, R.B.; Moore, T.N.

    1982-01-01

    The value of radiotherapy to the chest (RC) in disseminated small cell lung carcinoma (SCLC) has been questioned. Two protocols for disseminated SCLC from the Southwest Oncology Group (SWOG) have been compared. The first one included radiotherapy (RT), 3000 rad in two weeks, to the primary tumor, mediastinum and supraclavicular areas, while the second one deleted any RC. Multidrug chemotherapy (CT) and brain RT were used in both protocols. Nonresponders to CT were removed from the study. Our main findings are as follows: (1) Initial chest relapses (patients with no initial extrathoracic relapse) have increased from 24-55% when RC is not given (P = 0.0001). Overall chest relapse (adding those patients that relapsed simultaneously in the chest plus other sites) in the second protocol was 73%. (2) Amount of response to CT does not influence the chances for relapse. Even complete responders to CT have a high chance for chest relapse. (3) Sites of relapse without RC are mainly in the primary tumor, ipsilateral hilus and mediastinum. (4) With RC, relapses shift to the chest periphery, mostly to the lung outside the radiotherapy field and to the pleura. (5) The two very different CT regimens have produced similar percentages and duration of response. (6) CT schema with periodic reinductions prolongs duration of response and survival over schema with continuous maintenance. Hence, interruption of CT to allow RC does not seem to adversely influence CT efficacy

  19. A 26-year-old man with dyspnea and chest pain

    Directory of Open Access Journals (Sweden)

    Saurabh Mittal

    2017-01-01

    Full Text Available A 26-year-old smoker male presented with a history of sudden onset dyspnea and right-sided chest pain. Chest radiograph revealed large right-sided pneumothorax which was managed with tube thoracostomy. High-resolution computed tomography thorax revealed multiple lung cysts, and for a definite diagnosis, a video-assisted thoracoscopic surgery-guided lung biopsy was performed followed by pleurodesis. This clinicopathologic conference discusses the clinical and radiological differential diagnoses, utility of lung biopsy, and management options for patients with such a clinical presentation.

  20. A chest drainage system with a real-time pressure monitoring device.

    Science.gov (United States)

    Chen, Chih-Hao; Liu, Tsang-Pai; Chang, Ho; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung

    2015-07-01

    Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the "tidaling phenomenon" in the bottle can be reflective of the extent of patient's recovery. However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. The device is made of a pressure sensor with an operating range between -100 to +100 cmH2O and an amplifying using the "Wheatstone bridge" concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system.

  1. Thoracostomy tubes: A comprehensive review of complications and related topics

    Science.gov (United States)

    Kwiatt, Michael; Tarbox, Abigail; Seamon, Mark J.; Swaroop, Mamta; Cipolla, James; Allen, Charles; Hallenbeck, Stacinoel; Davido, H. Tracy; Lindsey, David E.; Doraiswamy, Vijay A.; Galwankar, Sagar; Tulman, David; Latchana, Nicholas; Papadimos, Thomas J.; Cook, Charles H.; Stawicki, Stanislaw P.

    2014-01-01

    Tube thoracostomy (TT) placement belongs among the most commonly performed procedures. Despite many benefits of TT drainage, potential for significant morbidity and mortality exists. Abdominal or thoracic injury, fistula formation and vascular trauma are among the most serious, but more common complications such as recurrent pneumothorax, insertion site infection and nonfunctioning or malpositioned TT also represent a significant source of morbidity and treatment cost. Awareness of potential complications and familiarity with associated preventive, diagnostic and treatment strategies are fundamental to satisfactory patient outcomes. This review focuses on chest tube complications and related topics, with emphasis on prevention and problem-oriented approaches to diagnosis and treatment. The authors hope that this manuscript will serve as a valuable foundation for those who wish to become adept at the management of chest tubes. PMID:25024942

  2. Pediatric chest CT after trauma: impact on surgical and clinical management

    International Nuclear Information System (INIS)

    Patel, Rina P.; Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H.; Yu, Chang; Ray, Jackie

    2010-01-01

    Chest CT after pediatric trauma is frequently performed but its clinical impact, particularly with respect to surgical intervention, has not been adequately evaluated. To assess the impact of chest CT compared with chest radiography on pediatric trauma management. Two hundred thirty-five consecutive pediatric trauma patients who had both chest CT and radiography were identified. Images were reviewed and findings were categorized and correlated with subsequent chest interventions, blinded to final outcome and management. Of the 235 children, 38.3% (90/235) had an abnormal chest radiograph and 63.8% (150/235) had an abnormal chest CT (P < 0.0001). Chest interventions followed in 4.7% (11/235); of these, the findings could be made 1 cm above the dome of the liver in 91% (10/11). Findings requiring chest intervention included pneumothorax (PTX) and vertebral fractures. PTX was found on 2.1% (5/235) of chest radiographs and 20.0% (47/235) of chest CTs (P < 0.0001); 1.7% (4/235) of the children received a chest tube for PTX, 0.85% (2/235) seen on chest CT only. Vertebral fractures were present in 3.8% of the children (9/235) and 66.7% (6/9) of those cases were treated with spinal fusion or brace. There were no instances of mediastinal vascular injury. Most intrathoracic findings requiring surgical management in our population were identified in the lower chest and would be included in routine abdominopelvic CT exams; this information needs to be taken into consideration in the diagnostic algorithm of pediatric trauma patients. (orig.)

  3. Pediatric chest CT after trauma: impact on surgical and clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rina P. [Vanderbilt University School of Medicine, Nashville, TN (United States); Hernanz-Schulman, Marta; Hilmes, Melissa A.; Kan, J.H. [Vanderbilt University, Department of Radiology and Radiological Sciences, Vanderbilt Children' s Hospital, Nashville, TN (United States); Yu, Chang [Vanderbilt University, Department of Biostatistics, Nashville, TN (United States); Ray, Jackie [Vanderbilt University, Department of Pediatric Surgery, Vanderbilt Children' s Hospital, Nashville, TN (United States)

    2010-07-15

    Chest CT after pediatric trauma is frequently performed but its clinical impact, particularly with respect to surgical intervention, has not been adequately evaluated. To assess the impact of chest CT compared with chest radiography on pediatric trauma management. Two hundred thirty-five consecutive pediatric trauma patients who had both chest CT and radiography were identified. Images were reviewed and findings were categorized and correlated with subsequent chest interventions, blinded to final outcome and management. Of the 235 children, 38.3% (90/235) had an abnormal chest radiograph and 63.8% (150/235) had an abnormal chest CT (P < 0.0001). Chest interventions followed in 4.7% (11/235); of these, the findings could be made 1 cm above the dome of the liver in 91% (10/11). Findings requiring chest intervention included pneumothorax (PTX) and vertebral fractures. PTX was found on 2.1% (5/235) of chest radiographs and 20.0% (47/235) of chest CTs (P < 0.0001); 1.7% (4/235) of the children received a chest tube for PTX, 0.85% (2/235) seen on chest CT only. Vertebral fractures were present in 3.8% of the children (9/235) and 66.7% (6/9) of those cases were treated with spinal fusion or brace. There were no instances of mediastinal vascular injury. Most intrathoracic findings requiring surgical management in our population were identified in the lower chest and would be included in routine abdominopelvic CT exams; this information needs to be taken into consideration in the diagnostic algorithm of pediatric trauma patients. (orig.)

  4. A Community-acquired Lung Abscess Attributable to Streptococcus pneumoniae which Extended Directly into the Chest Wall.

    Science.gov (United States)

    Ko, Yuki; Tobino, Kazunori; Yasuda, Yuichiro; Sueyasu, Takuto; Nishizawa, Saori; Yoshimine, Kouhei; Munechika, Miyuki; Asaji, Mina; Yamaji, Yoshikazu; Tsuruno, Kosuke; Miyajima, Hiroyuki; Mukasa, Yosuke; Ebi, Noriyuki

    We herein report the case of 75-year-old Japanese female with a community-acquired lung abscess attributable to Streptococcus pneumoniae (S. penumoniae) which extended into the chest wall. The patient was admitted to our hospital with a painful mass on the left anterior chest wall. A contrast-enhanced chest computed tomography scan showed a lung abscess in the left upper lobe which extended into the chest wall. Surgical debridement of the chest wall abscess and percutaneous transthoracic tube drainage of the lung abscess were performed. A culture of the drainage specimen yielded S. pneumoniae. The patient showed a remarkable improvement after the initiation of intravenous antibiotic therapy.

  5. Use of a Nasal Speculum for Chest-Drain Insertion: A Simple Technique

    OpenAIRE

    Saxena, Pankaj; Konstantinov, Igor E.; Newman, Mark A.J.

    2006-01-01

    Tube thoracostomy is a very commonly performed procedure in cardiothoracic surgery. Insertion of a chest drain requires expertise to minimize complications. We describe a simple technique of using a nasal speculum to perform this procedure.

  6. Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms.

    Science.gov (United States)

    Shimonobo, Toshiaki; Funama, Yoshinori; Utsunomiya, Daisuke; Nakaura, Takeshi; Oda, Seitaro; Kiguchi, Masao; Masuda, Takanori; Sakabe, Daisuke; Yamashita, Yasuyuki; Awai, Kazuo

    2016-01-01

    We used pediatric and adult anthropomorphic phantoms to compare the radiation dose of low- and standard tube voltage chest and abdominal non-contrast-enhanced computed tomography (CT) scans. We also discuss the optimal low tube voltage for non-contrast-enhanced CT. Using a female adult- and three differently-sized pediatric anthropomorphic phantoms we acquired chest and abdominal non-contrast-enhanced scans on a 320-multidetector CT volume scanner. The tube voltage was set at 80-, 100-, and 120 kVp. The tube current was automatically assigned on the CT scanner in response to the set image noise level. On each phantom and at each tube voltage we measured the surface and center dose using high-sensitivity metal-oxide-semiconductor field-effect transistor detectors. The mean surface dose of chest and abdominal CT scans in 5-year olds was 4.4 and 5.3 mGy at 80 kVp, 4.5 and 5.4 mGy at 100 kV, and 4.0 and 5.0 mGy at 120 kVp, respectively. These values were similar in our 3-pediatric phantoms (p > 0.05). The mean surface dose in the adult phantom increased from 14.7 to 19.4 mGy for chest- and from 18.7 to 24.8 mGy for abdominal CT as the tube voltage decreased from 120 to 80 kVp (p voltage and the low tube voltage technique can be used for non-contrast-enhanced chest- and abdominal scanning. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Kaup, Moritz; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik [Goethe University of Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-06-15

    Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance. To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT. Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters. Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2). Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration. (orig.)

  8. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality

    International Nuclear Information System (INIS)

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Kaup, Moritz; Beeres, Martin; Vogl, Thomas J.; Scholtz, Jan-Erik

    2017-01-01

    Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance. To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT. Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters. Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2). Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration. (orig.)

  9. Dose and perceived image quality in chest radiography

    International Nuclear Information System (INIS)

    Veldkamp, Wouter J.H.; Kroft, Lucia J.M.; Geleijns, Jacob

    2009-01-01

    Chest radiography is the most commonly performed diagnostic X-ray examination. The radiation dose to the patient for this examination is relatively low but because of its frequent use, the contribution to the collective dose is considerable. Consequently, optimization of dose and image quality offers a challenging area of research. In this article studies on dose reduction, different detector technologies, optimization of image acquisition and new technical developments in image acquisition and post processing will be reviewed. Studies indicate that dose reduction in PA chest images to at least 50% of commonly applied dose levels does not affect diagnosis in the lung fields; however, dose reduction in the mediastinum, upper abdomen and retrocardiac areas appears to directly deteriorate diagnosis. In addition to patient dose, also the design of the various digital detectors seems to have an effect on image quality. With respect to image acquisition, studies showed that using a lower tube voltage improves visibility of anatomical structures and lesions in digital chest radiographs but also increases the disturbing appearance of ribs. New techniques that are currently being evaluated are dual energy, tomosynthesis, temporal subtraction and rib suppression. These technologies may improve diagnostic chest X-ray further. They may for example reduce the negative influence of over projection of ribs, referred to as anatomic noise. In chest X-ray this type of noise may be the dominating factor in the detection of nodules. In conclusion, optimization and new developments will enlarge the value of chest X-ray as a mainstay in the diagnosis of chest diseases.

  10. Outcome of penetrating chest injuries in an urban level I trauma center in the Netherlands.

    Science.gov (United States)

    Heus, C; Mellema, J J; Giannakopoulos, G F; Zuidema, W P

    2015-04-25

    Most patients with penetrating chest injuries benefit from early treatment with chest tube drainage or surgery. Although penetrating chest injury is not uncommon, few descriptive studies are published, especially in Europe. The aim of this study was to review our experience and further improve our management of penetrating chest injuries in a level I trauma center in the Netherlands. All patients with penetrating chest injury between August 2004 and December 2012 were included. Demographics, mechanism of injury, physiological parameters, Injury Severity Scores (ISS), surgical and non-surgical treatment, length of intensive care unit (ICU) stay, length of hospital stay (LOS), complications and rate of mortality were collected. A total of 159 patients were analyzed. Patients included 116 (73 %) stab wounds and 34 (21 %) gunshot wounds. In 27 patients (17 %), cardiac injury was seen. The mean ISS was 12. Almost half of all patients (49 %) were treated with only chest tube drainage. Alternatively, surgical treatment was performed in 24 % of all cases. Anterolateral incision was most frequently used to gain access to the thoracic cavity. The mean LOS was 9 days. Among all patients, 17 % were admitted to the ICU with a mean stay of 3 days. In 18 (11 %) patients, one or more complications occurred. The 30-day mortality was 7.5 %. Patients presenting with penetrating chest injury are not uncommon in the Netherlands and can mostly be treated conservatively. In one-fourth of the patients, surgical treatment is performed. A structural and vigorous approach is needed for good clinical outcome.

  11. Routinely obtained chest X-rays after elective video-assisted thoracoscopic surgery can be omitted in most patients; a retrospective, observational study

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jensen, Katrine; Petersen, René Horsleben

    2015-01-01

    divided into three groups according to the degree of pulmonary resection. The chest X-rays (obtained anterior-posterior in one plane with the patient in the supine position) were categorized as abnormal if showing pneumothorax >5 cm, possible intra-thoracic bleeding and/or a displaced chest tube. Medical....... Proportions of abnormal chest X-rays were unequally distributed between groups (p pneumothorax >5 cm and one showed a kinked chest...

  12. A prospective randomized, controlled trial deems a drainage of 300 ml/day safe before removal of the last chest drain after video-assisted thoracoscopic surgery lobectomy.

    Science.gov (United States)

    Xie, Hong-Ya; Xu, Kai; Tang, Jin-Xing; Bian, Wen; Ma, Hai-Tao; Zhao, Jun; Ni, Bin

    2015-08-01

    To study the feasible and safe volume threshold for chest tube removal following video-assisted thoracoscopic surgical lobectomy. One hundred and sixty-eight consecutive patients (18 were excluded) who underwent video-assisted thoracoscopic surgery lobectomy or bilobectomy with two incisions between August 2012 and February 2014 were included. Eligible patients were randomized into three groups: Group A (chest tube was removed at a drainage volume of 150 ml/day or less. n = 49); Group B (chest tube was removed when the drainage volume was less than 300 ml/day. n = 50); Group C (chest tube was removed when the drainage volume was less than 450 ml/day. n = 51). The postoperative care of all patients was consistent. The time of extracting the drainage tube, postoperative hospital stay, postoperative visual analogue scale grades, dosage of analgesic, and the incidence of complications and thoracocentesis were measured. Group B and C had a much shorter drainage time and postoperative hospital stay than Group A (P 0.05). The mean dosage of pethidine hydrochloride was 248.9 ± 33.3 mg in Group B and 226.1 ± 32.7 mg in Group C (P > 0.05). The dosage of pethidine hydrochloride of Group A was significantly higher than that of Group B and C (P 0.05), Group A had a significantly higher total VAS score than Group B and C (P drains among the three groups (P > 0.05). A 300-ml/day volume threshold for chest tube removal after video-assisted thoracoscopic surgery lobectomy is feasible and safe, demonstating more advantages than the 150-ml/day volume threshold. However, a 450-ml/day volume threshold for chest tube removal may increase the risk of thoracentesis compared with the 300- and the 150-ml/day volume threshold. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Bilateral primary fallopian tube papillary serous carcinoma in postmenopausal woman: Report of two cases

    Directory of Open Access Journals (Sweden)

    Dipanwita Nag

    2016-01-01

    Full Text Available Primary carcinoma of the fallopian tube is rare and accounts for about 0.14-1.8% of all gynecological malignancies. Correct diagnosis is rarely made preoperatively as clinically tubal carcinoma closely resembles ovarian carcinoma. Here, we report two cases of bilateral primary fallopian tube carcinomas. Case 1: A 54-year-old female presented with postmenopausal bleeding, abdominal pain, and pervaginal watery discharge for 10 days. Ultrasonography (USG of pelvis showed endometrial thickening and multiple tiny echogenic foci in omentum suggestive of omental cake. With a provisional diagnosis of endometrial carcinoma, total abdominal hysterectomy with bilateral salpingo-oophorectomy and omentectomy was done. On gross examination, small and rudimentary right ovary was adherent to the fimbrial end of the tube. Left-sided tubo-ovarian mass was present, cut section of which showed yellowish solid area in tubal wall and encroaching on ovarian surface. On histological examination, sections from the fimbrial end of both fallopian tubes showed features of papillary serous adenocarcinoma. Case 2: 70-year-old lady, 15 years postmenopausal presented with gradual onset pain and swelling of abdomen, urinary incontinence since 4 days. USG showed bulky uterus, 5 cm × 2 cm fibroid, bilateral tubes, and ovaries were not visualized. Serum cancer antigen-125 was raised (159.7 U/ml. Total hysterectomy and bilateral salpingo-oophorectomy with infracolic omentectomy was done. On gross examination, ovaries were firmly attached to tubes and no apparent solid area was noted. On microscopy, papillary serous adenocarcinoma arising from tubal wall was seen infiltrating focally into ovarian stroma; tubal epithelium showed dysplastic change. Sections from omentum showed numerous psammoma bodies.

  14. Apparatus for forming an explosively expanded tube-tube sheet joint

    International Nuclear Information System (INIS)

    Schroeder, J.W.

    1984-01-01

    The invention relates to apparatus for expanding a tube into a bore formed in a tube sheet. According to the invention, a primary explosive containing a relatively high number of grains of explosive per unit length extends within the tube coextensive with that portion of the tube to be expanded. An energy transfer cord extends between a detonator and the primary explosive and includes a relatively low number of grains of explosive per unit length which are insufficient to detonate the primary explosive. The transfer cord is covered by a sheath to contain the debris and gases associated with the explosion of the explosive therein. A booster extends between the energy transfer cord and the primary explosive and contains an explosive which can be detonated by the explosive in the energy transfer cord and can, upon exploding, in turn detonate the primary explosive. (author)

  15. Nurses’ Knowledge Levels of Chest Drain Management: A Descriptive Study

    Directory of Open Access Journals (Sweden)

    Merve Tarhan

    2016-12-01

    Full Text Available Objective: The physician is responsible for inserting one or more chest tubes into the pleural space or the mediastinal space and connecting them to an appropriate drainage system. When the general principles about care of patients with chest drains were implemented correctly and effectively by nurses, nurse will contribute to accelerate the healing process of patients. In this context, the aim of this study was to determine the nurses’ level of knowledge regarding the care of patients with chest drains. Methods: The study was conducted with 153 nurses who worked in a chest diseases and thoracic surgery hospital in July 2014. Questionnaire form of 35 questions prepared by investigators was used to collect data. For the analysis of results, frequency tests, independent sample t-test and oneway ANOVA test were used. Results: 69.3% of nurses stated that they had obtained information from colleguages. 35.3% considered their knowledge about chest drain management to be inadequate. 55.6% scored 13 points and above from knowledge questionnaire about chest drain management. There were statistically significant difference between knowledge level and educational background, clinic work type, working unit, years of professional experience and institutional experience, frequency of contact patients with chest drain and perception of knowledge level (p<0.05. Conclusion: Results of this study indicate that lack of evidence-based nursing care and insufficient training has resulted in uncertainty and knowledge deficit in important aspects of chest drain care. It can be concluded that nurses receive training needs and training protocols are about chest drain management.

  16. Tube Thoracostomy-Related Necrotizing Fasciitis: A Case Report

    Directory of Open Access Journals (Sweden)

    Shun-Pin Hsu

    2006-12-01

    Full Text Available Spontaneous pneumothorax is a serious complication of pulmonary tuberculosis that requires immediate treatment. Necrotizing fasciitis is a serious, rapidly progressive infection of the subcutaneous tissue and fascia, most related to trauma or surgery. Here, we report a case of pulmonary tuberculosis with spontaneous pneumothorax. A standard procedure of tube thoracostomy was performed for lung re-expansion. Two days after the tube was removed, necrotizing fasciitis developed from the puncture site. Computed tomography of the chest showed focal thickness with gas formation and loss of the fat plane over the chest wall, which is compatible with the diagnosis of necrotizing fasciitis. Aggressive treatment was given, including emergency fasciectomy and adequate systemic antibiotic and antituberculous treatment. The necrotizing fasciitis was successfully treated. The patient was discharged and sent home with maintenance antituberculous therapy.

  17. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  18. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  19. Experiences with a new film-screen system in pediatric chest radiography

    International Nuclear Information System (INIS)

    Leenen, A.; Brandt, G.A.; Riebel, T.; Marciniak, H.

    1996-01-01

    Purpose: To compare the X-ray images made by the Kodak InSight Pediatric Imaging System (InSight P) with conventional film-screen systems in pediatric chest radiography. Material and methods: The comparison involved chest radiographs made using Quanta-Fast-Detail/Cronex 4 (DuPont), Trimax 16/XDA (3 M) and DuPont UVR/UVL systems. The image quality of critical structures and the physical parameters of quantum interference, contrast and resolution were assessed. The energy path of the system was assessed by preparing density curves. Test conditions were in accordance with the latest guidelines of the Bundesaerztekammer (German Physicians' Association). Results: The mediastinal area, retrocardiac and paravertebral spaces and the peripheral vessels of the lung were all displayed more distinctly using InSight P. The reason for this seems to be a lower degree of quantum interference associated with this system. With tube voltages between 60 and 80 kV, InSight P displayed a relatively low degree of sensitivity. Conclusion: InSight P can be used to produce predominantly high quality chest radiographs on infants between one and five years of age. However, this system has limited sensitivity in the tube voltage range recommended by the German Physicians' Association. (orig.) [de

  20. Practical applications of digital tomosynthesis of the chest

    International Nuclear Information System (INIS)

    Galea, A.; Durran, A.; Adlan, T.; Gay, D.; Riordan, R.; Dubbins, P.; Williams, M.P.

    2014-01-01

    Digital tomosynthesis is a radiographic technique that generates a number of coronal raw images of a patient from a single pass of the x-ray tube. Tomosynthesis provides some of the tomographic benefits of computed tomography (CT), but at a much lower dose of radiation and cost when compared to CT. This review illustrates the range of practical applications of digital tomosynthesis of the chest

  1. Limiting chest computed tomography in the evaluation of pediatric thoracic trauma.

    Science.gov (United States)

    Golden, Jamie; Isani, Mubina; Bowling, Jordan; Zagory, Jessica; Goodhue, Catherine J; Burke, Rita V; Upperman, Jeffrey S; Gayer, Christopher P

    2016-08-01

    Computed tomography (CT) of the chest (chest CT) is overused in blunt pediatric thoracic trauma. Chest CT adds to the diagnosis of thoracic injury but rarely changes patient management. We sought to identify a subset of blunt pediatric trauma patients who would benefit from a screening chest CT based on their admission chest x-ray (CXR) findings. We hypothesize that limiting chest CT to patients with an abnormal mediastinal silhouette identifies intrathoracic vascular injuries not otherwise seen on CXR. All blunt trauma activations that underwent an admission CXR at our Level 1 pediatric trauma center from 2005 to 2013 were retrospectively reviewed. Patients who had a chest CT were evaluated for added diagnoses and change in management after CT. An admission CXR was performed in 1,035 patients. One hundred thirty-nine patients had a CT, and the diagnosis of intra-thoracic injury was added in 42% of patients. Chest CT significantly increased the diagnosis of contusion or atelectasis (30.3% vs 60.4%; p pneumothorax (7.2% vs 18.7%; p chest CT. Chest CT changed the management of only 4 patients (2.9%). Two patients underwent further radiologic evaluation that was negative for injury, one had a chest tube placed for an occult pneumothorax before exploratory laparotomy, and one patient had a thoracotomy for repair of aortic injury. Chest CT for select patients with an abnormal mediastinal silhouette on CXR would have decreased CT scans by 80% yet still identified patients with an intrathoracic vascular injury. The use of chest CT should be limited to the identification of intrathoracic vascular injuries in the setting of an abnormal mediastinal silhouette on CXR. Therapeutic study, level IV; diagnostic study, level III.

  2. Reconstruction of the chest wall after excision of a giant malignant ...

    African Journals Online (AJOL)

    Primary chest wall tumors are uncommon and constitute 0.2-2% of all tumors. Metastatic tumors and tumors of local extension are more common. Malignant peripheral nerve sheath tumor (MPNST) of the chest wall is even rarer and its incidence on the chest wall not stated in the literature. The incidence in the general ...

  3. The Role of Incentive Spirometry in Primary Spontaneous Pneumothorax.

    Science.gov (United States)

    Pribadi, Rabbinu R; Singh, Gurmeet; Rumende, Cleopas M

    2016-01-01

    Pneumothorax is the presence of air in the pleural space. Its management consists of noninvasive and invasive therapies and it is determined based on clinical manifestations, type and size of pneumothorax. We present a case of a patient with diagnosis of primary spontaneous pneumothorax treated with incentive spirometry (noninvasive therapy). A 20 year old man came to respirology clinic with chief complaint of shortness of breath. He was recently diagnosed with left pneumothorax based on previous chest X-ray in another health care facilities and was advised to undergo tube thoracostomy but he refused the procedure. On physical examination, vital signs were normal. Chest X-ray showed 33% of pneumothorax or 1.2 cm. He was asked to perform incentive spirometry therapy at home. During 12 days of therapy, shortness of breath slowly disappeared and on repeated chest X-ray, it showed minimal pneumothorax in the left upper hemithorax. Noninvasive treatment such as incentive spirometry can be considered in patient with minimal symptoms and no signs of life-threatening respiratory distress.

  4. Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Saunderson, J R; Beavis, A W

    2015-01-01

    This work assessed the appropriateness of the signal-to-noise ratio improvement factor (K SNR ) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients  =  80). The K SNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. K SNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and K SNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of  −0.93 (p  =  0.015) was found for lung, a coefficient (R) of  −0.95 (p  =  0.46) was found for spine, and a coefficient (R) of  −0.85 (p  =  0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. K SNR increases with tube voltage but VGAS decreases. Medical physicists should use the K SNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely. (paper)

  5. Maximum utilization of primary reformer catalyst tubes careful assessment of remaining life-An experience at an ammonia plant

    International Nuclear Information System (INIS)

    Malik, M.A.

    2005-01-01

    Condition evaluation and residual life assessment of Reformer Catalyst Tubes has always been a point of concern for Ammonia and Methanol Plant operators. Failure of catalyst tubes results in total plant shutdown and consequent production loss. On the other hand, replacement of these tubes entails major cost impact on the company's budget, being a capital expenditure. A careful Residual Life Assessment of the tubes is therefore of utmost importance for maximum utilization of these tubes without jeopardizing plant operational reliability. This paper presents an experience of extracting maximum service life from the catalyst tubes of Primary Reformer of an Ammonia Plant. Fauji Fertilizer Company (FFC) has been operating the plant since 1982, having a designed capacity of 1100 MTPD. Its Primary Reformer has 288 catalyst tubes of IN-519 material (24Cr-24Ni-Nb). The design temperature and pressures are 925 degree C and 38kg/Cm respectively. Thanks to the optimum operating conditions, regular inspections and careful assessment of the residual life, the tubes have achieved more than double of the designed life and are still operating reliably. To evaluate the tube's health, Ultrasonic Inspection (UT) was carried out in 1987 and 1994 using attenuation technique. The tubes with maximum attenuation were marked for further evaluation. Accelerated Creep Rupture Test was carried out on sample tubes periodically (1996, 2001 and 2004). Tubes were selected on the basis of UT results, TMT (Tube Metal Temperature) monitoring and Inspection findings. Based on the combined results of DT, NDT, equipment history and foreseen operational parameters, the life of these tubes was carefully assessed periodically. The tubes have been in service for more than 23 years (design life: 11 years) and a further life of 04 years has been predicted as per last assessment.The experience of successful health evaluation and residual life assessment has saved substantial cost involved in tubes replacement

  6. Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

    Science.gov (United States)

    Sogur, Elif; Baksı, B Güniz; Orhan, Kaan; Paksoy, S Candan; Dogan, Salih; Erdal, Yılmaz S; Mert, Ali

    2011-12-01

    The aim of this study was to assess the detection of proximal caries in primary teeth at three different tube potentials using Ektaspeed films, storage phosphor plates (SPPs), and a charge-coupled device (CCD). Fifty-three extracted human primary molars with natural proximal caries were radiographed with three different imaging modalities--Digora Optime SPP system, RVGui CCD system, and Ektaspeed films--at 50-, 65-, and 70-kV tube potentials. Three observers scored the resultant images for the presence or absence of caries. The definitive diagnosis was determined by stereomicroscopic assessment. The diagnostic accuracy for each imaging modality was expressed as the area under the receiver operating characteristic curves (A(z)). Differences among the A(z) values were assessed using two-way ANOVA and t tests. Kappa was used to measure inter- and intra-observer agreement. Higher accuracy was found for SPPs compared to film and CCD images at all tube potentials. Accuracy was significantly different only at 50-kV tube setting in favor of SPPs (p tube potential for the diagnosis of proximal caries since further advantages include the elimination of chemical processing, image enhancement, and a better low-contrast detectability performance.

  7. Staphylococcus aureus sternal osteomyelitis: a rare cause of chest pain

    Directory of Open Access Journals (Sweden)

    Kaur M

    2015-10-01

    Full Text Available Chest pain is a common presenting symptom with a broad differential. Life-threatening cardiac and pulmonary etiologies of chest pain should be evaluated first. However, it is critical to perform a thorough assessment for other sources of chest pain in order to limit morbidity and mortality from less common causes. We present a rare case of a previously healthy 45 year old man who presented with focal, substernal, reproducible chest pain and Staphylococcus aureus bacteremia who was later found to have primary Staphylococcus aureus sternal osteomyelitis.

  8. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, pchest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  9. Occult pneumothorax in blunt trauma: is there a need for tube thoracostomy?

    Science.gov (United States)

    Zhang, M; Teo, L T; Goh, M H; Leow, J; Go, K T S

    2016-12-01

    Occult pneumothorax (OPTX) is defined as air within the pleural cavity that is undetectable on normal chest X-rays, but identifiable on computed tomography. Currently, consensus is divided between tube thoracostomy and conservative management for OPTX. The aim of this retrospective study is to determine whether OPTX can be managed conservatively and whether any adverse events occur under conservative management. Data on all trauma patients from 1 Jan 2010 to 31 December 2012 were obtained from our hospital's trauma registry. All patients with occult pneumothorax who had chest X-ray (CXR) and any CT scan visualizing the thorax were included. The exclusion criteria included those with penetrating wounds; CXR showing pneumothorax, hemothorax, or hemopneumothorax; those with prophylactic chest tube insertion before CT; and those with no CT diagnosis of OPTX. The complications of these patients were analyzed to determine if tube thoracostomy is necessary for OPTX and whether not inserting it would alter the outcome significantly. A total of 1564 cases were reviewed and 83 patients were included. Of these 83 patients, 35 (42.2 %) had tube thoracostomy after OPTX detection and 48 (57.8 %) were observed initially. Patients who had tube thoracostomy had similar ISS compared to those without (median ISS 17 vs. 18.5, p = 0.436). Out of the 48 patients who did not have tube thoracostomy on detection of an OPTX, 4 (8.3 %) had complications. In the group of 35 patients who had tube thoracostomy on detection of an OPTX, 7 (20 %) had complications. Of the 83 patients, a total of 12 patients had IPPV, of which 7 (58.3 %) had tube thoracostomy and 5 (41.7 %) did not. Patients who had tube thoracostomy under our care have a statistically significant likelihood of experiencing any complication compared to those without tube thoracostomy (odds ratio 9.92. The median length of stay was also longer (13 days) in those who had tube thoracostomy compared to those without (5

  10. Predictors of Adverse Outcomes of Patients with Chest Pain and Primary Diagnosis of Non-Cardiac Pain at the Time of Discharge from Emergency Department: A 30-Days Prospective Study.

    Science.gov (United States)

    Soltani, Mohammadhossien; Mirzaei, Masoud; Amin, Ahmad; Emami, Mahmoud; Aryanpoor, Reza; Shamsi, Farimah; Sarebanhassanabadi, Mohammadtaghi

    2016-07-01

    Chest pain is a common symptom for referring patients to emergency departments (ED). Among those referred, some are admitted to hospitals with a definite or tentative diagnosis of acute coronary syndrome and some are discharged with primary diagnosis of non-cardiac chest pain. This study aimed at investigating 30 days' adverse outcomes of patients discharged from ED of a major heart center in Iran. Out of 1638 chest pain admissions to the centre during 2010-2011, 962 patients (mean age= 50.9±15.9 years) who were admitted to Afshar Heart Center's ED with chest pain as their chief complaint, and discharged with primary diagnosis of non-cardiac chest pain, were followed for any adverse cardiac events 30 days post discharge. The adverse events were: unstable angina, non-ST-elevated myocardial infarction (NSTEMI), ST elevated myocardial infarction (STEMI), coronary revascularization (percutaneous angioplasty, coronary artery bypass grafting) and death. Adverse cardiac events, including acute coronary syndrome (ACS), revascularization and death were observed in 30 patients (3.1%) including: acute MI n=5 (0.5%, sudden cardiac death inn=1 (0.1%, coronary revascularization in n=8 (0.8%) and hospitalization due to unstable angina/NSTEMI in n=16 (1-7%). Adverse events were seen more frequently in patients with history of hypertension, dyslipidemia and previous coronary artery disease. In univariate analysis, the chance of postdischarge adverse cardiac events was higher in patients with hypertension (OR=9.36, CI=3.24-27.03), previous coronary artery disease (OR= 3.8, CI=1.78-8.0), dyslipidemia (OR=3.5, CI=1.7-7.38) and discharge against medical advice (OR=2.85, CI= 1.37-5.91). The extent of adverse cardiac events in patients with a primary diagnosis of non-cardiac chest pain within 30 days of discharge was significant, mandating nation-wide registries to provide better care for these patients.

  11. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial.

    Science.gov (United States)

    da Conceição Dos Santos, Elinaldo; Lunardi, Adriana Claudia

    2015-04-01

    Chest drainage for pleural effusion can cause pain and changes in respiratory function. It can also increase the risk of pulmonary complications and impair functional ability, which may increase length of hospital stay and the associated costs. For these reasons, surgical and clinical strategies have been adopted to reduce the duration of chest drainage. To evaluate the efficacy of the addition of intermittent positive airway pressure applied by the Muller reanimator via a rubber facial mask versus conventional physiotherapy on the duration of chest drainage (primary objective), and its effect on the recovery of respiratory function, length of hospital stay and incidence of pulmonary complications (secondary objectives). Randomised, controlled trial. Inpatients with pleural effusion, aged over 18 years, who have had chest drainage in situ for drain will be a transudate output ≤ 200ml over 24hours and full lung expansion on chest radiography, as assessed by a blinded physician. Duration of chest drainage, length of hospital stay, and any pulmonary complications diagnosed during hospitalisation will be recorded. Intention to treat using: survival analysis for duration of chest drainage, and length of hospital stay; analysis of variance for chest-tube output, lung function and peripheral oxygen saturation; and chi-square tests for comparing the incidence of pulmonary complications between groups. Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications

  12. Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Shinozaki, Masayuki; Furusawa, Takayuki [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Wada, Shigeyuki

    1999-08-01

    The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

  13. Chemotherapy Toxicity On Quality of Life in Older Patients With Stage I, Stage II, Stage III, or Stage IV Ovarian Epithelial, Primary Peritoneal Cavity, or Fallopian Tube Cancer

    Science.gov (United States)

    2017-05-03

    Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  14. Primary water stress corrosion cracking resistance of alloy X-750 for guide tube support pins

    International Nuclear Information System (INIS)

    Yonezawa, T.; Onimura, K.; Yonehana, M.; Fujitani, T.

    1990-01-01

    The authors have developed the maintenance free guide tube support pins for PWR, and conducted the three kinds of long time stress corrosion cracking tests in high temperature water, in order to verify the reliability of the maintenance free guide tube support pins. This paper describes the features of our maintenance free support pins and the results of long time stress corrosion cracking test for the maintenance free support pins. After exposure at 320 0 C in the simulated primary water of PWR for about 35,000 hours or at 360 0 C in the same chemistry water as the primary water for about 24,900 hours, no abnormal indication such as cracks was observed in all test support pins exposed 320 0 C and 360 0 C primary water, by ultrasonic inspection, and liquid penetrate test. From the above, it seems that our maintenance free support pins are keepable the soundness up to the end of plant life, in PWR plants

  15. Should the lateral chest radiograph be routinely performed?

    International Nuclear Information System (INIS)

    Osman, Fatuma; Williams, Imelda

    2014-01-01

    Background: The chest x-ray is one of the most common plain film radiographic examinations performed. Inclusion of the lateral chest radiograph varies internationally and nationally across radiology departments and states in Australia. Search strategy: A search strategy of the databases Cochrane Library, Ovid Medline/Medline, PubMed, Scopus and Science Direct was conducted. The results were restricted to those published between 1985 and 2013 and those published in English. The following search terms were used: ‘lateral chest’, ‘radiograph’, ‘digital radiography’, ‘chest x-ray’, ‘plain film radiography’, ‘ionising radiation’. The results were restricted to publications with these terms in the title, abstract and/or keywords. Main findings: There are few national or international guidelines pertaining to the inclusion of the lateral chest x-ray as routine. Primary concerns are the increased radiation dose associated with the additional chest view and reduction of medical imaging services cost. Modern digital imaging systems result in a lower radiation dose. The diagnostic yield of the lateral chest x-ray is highly dependent on the clinical indications of the patient. Further research into the routine inclusion of the lateral chest x-ray is recommended. Conclusion: Review of the literature suggests that the lateral chest radiograph should not be performed routinely unless clinically indicated

  16. Predictors of Adverse Outcomes of Patients with Chest Pain and ...

    African Journals Online (AJOL)

    Background: Chest pain is a common symptom for referring patients to emergency departments (ED). Among those referred, some are admitted to hospitals with a definite or tentative diagnosis of acute coronary syndrome and some are discharged with primary diagnosis of non-cardiac chest pain. This study aimed at ...

  17. Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling.

    Science.gov (United States)

    Söderberg, Johan; Brulin, Christine; Grankvist, Kjell; Wallin, Olof

    2009-01-01

    Most errors in laboratory medicine occur in the preanalytical phase and are the result of human mistakes. This study investigated information search procedures, test request management and test tube labelling in primary healthcare compared to the same procedures amongst clinical laboratory staff. A questionnaire was completed by 317 venous blood sampling staff in 70 primary healthcare centres and in two clinical laboratories (response rate = 94%). Correct procedures were not always followed. Only 60% of the primary healthcare staff reported that they always sought information in the updated, online laboratory manual. Only 12% reported that they always labelled the test tubes prior to drawing blood samples. No major differences between primary healthcare centres and clinical laboratories were found, except for test tube labelling, whereby the laboratory staff reported better practices. Re-education and access to documented routines were not clearly associated with better practices. The preanalytical procedure in the surveyed primary healthcare centres was associated with a risk of errors which could affect patient safety. To improve patient safety in laboratory testing, all healthcare providers should survey their preanalytical procedures and improve the total testing process with a systems perspective.

  18. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2011-01-01

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient (γ 2 = 0.86, P 2 vs. 326.3 ± 124.8 cm 2 ), mean density (-212.9 ± 53.1 HU vs. -221.1 ± 56.3 HU), and image noise (13.8 ± 2.3 vs. 13.6 ± 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  19. Primary closure versus T-tube drainage in laparoscopic common bile duct exploration: a meta-analysis of randomized clinical trials.

    Science.gov (United States)

    Wu, Xiangsong; Yang, Yong; Dong, Ping; Gu, Jun; Lu, Jianhua; Li, Maolan; Mu, Jiasheng; Wu, Wenguang; Yang, Jiahua; Zhang, Lin; Ding, Qichen; Liu, Yingbin

    2012-08-01

    To compare the safety and effectiveness of primary closure with those of T-tube drainage in laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis. A comprehensive search was performed in the PubMed, EmBase, and Cochrane Library databases. Only randomized controlled trials comparing primary closure with T-tube drainage in LCBDE were considered eligible for this meta-analysis. The analyzed outcome variables included postoperative mortality, overall morbidity, biliary complication rate, biliary leak rate, reoperation, operating time, postoperative hospital stay, time to abdominal drain removal, and retained stone. All calculations and statistical tests were performed using ReviewerManager 5.1.2 software. A total of 295 patients (148 patients with primary closure and 147 patients with T-tube drainage) from three trials were identified and analyzed. No deaths occurred in any of the trials. Primary closure showed significantly better results in terms of morbidity (risk ratio (RR), 0.51; 95% confidence interval (CI), 0.30 to 0.88), biliary complication without a combination of retained stone (RR, 0.44; 95% CI, 0.20 to 0.97), reoperation (RR, 0.16; 95% CI, 0.03 to 0.87), operating time (mean difference (MD), -20.72; 95% CI, -29.59 to -11.85), postoperative hospital stay (MD, -3.24; 95% CI, -3.96 to -2.52), and time to abdominal drainage removal (MD, -0.45; 95% CI, -0.86 to -0.04). Statistically significant differences were not found between the two methods in terms of biliary leak, biliary complication, and retained stones. The current meta-analysis indicates that primary closure of the common bile duct is safer and more effective than T-tube drainage for LCBDE. Therefore, we do not recommend routine performance of T-tube drainage in LCBDE.

  20. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system

    International Nuclear Information System (INIS)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R; Avery, G; Balcam, S; Needler, L

    2014-01-01

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQ m ), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQ m  and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma. (paper)

  1. An investigation of automatic exposure control calibration for chest imaging with a computed radiography system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R

    2014-05-07

    The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.

  2. Occult pneumothorax in the blunt trauma patient: tube thoracostomy or observation?

    Science.gov (United States)

    Wilson, Heather; Ellsmere, James; Tallon, John; Kirkpatrick, Andrew

    2009-09-01

    The term occult pneumothorax (OP) describes a pneumothorax that is not suspected on the basis of either clinical examination or initial chest radiography, but is subsequently detected on computed tomography (CT) scan. The optimal management of OP in the blunt trauma setting remains controversial. Some physicians favour placement of a thoracostomy tube for patients with OP, particularly those undergoing positive pressure ventilation (PPV), while others favour close observation without chest drainage. This study was conducted both to determine the incidence of OP and to describe its current treatment status in the blunt trauma population at a Canadian tertiary trauma centre. Of interest were the rates of tube thoracostomy vs. observation without chest drainage and their respective outcomes. A retrospective review was conducted of the Nova Scotia Trauma Registry. The data on all consecutive blunt trauma patients between October 1994 and March 2003 was reviewed. Outcome measures evaluated include length of stay, discharge status-dead vs. alive, intervention and time to intervention (tube thoracostomy and its relation to institution of PPV). Direct comparison was made between the OP with tube thoracostomy group and OP without tube thoracostomy group (observation or control group). They were compared in terms of their baseline characteristics and outcome measures. In 1881 consecutive blunt trauma patients over a 102-month period there were 307 pneumothoraces of which 68 were occult. Thirty five patients with OP underwent tube thoracostomy, 33 did not. Twenty nine (82.8%) with tube thoracostomy received positive pressure ventilation (PPV), as did 16 (48.4%) in the observation group. Mean injury severity score (ISS) for tube thoracostomy and observation groups were similar (25.80 and 22.39, p=0.101) whereas length of stay (LOS) was different (17.4 and 10.0 days, p=0.026). Mortality was similar (11.4% and 9.1%). There were no tension pneumothoraces. The natural history of

  3. Tube Thoracostomy: Complications and Its Management

    Directory of Open Access Journals (Sweden)

    Emeka B. Kesieme

    2012-01-01

    Full Text Available Background. Tube thoracostomy is widely used throughout the medical, surgical, and critical care specialities. It is generally used to drain pleural collections either as elective or emergency. Complications resulting from tube thoracostomy can occasionally be life threatening. Aim. To present an update on the complications and management of complications of tube thoracostomy. Methods. A review of the publications obtained from Medline search, medical libraries, and Google on tube thoracostomy and its complications was done. Results. Tube thoracostomy is a common surgical procedure which can be performed by either the blunt dissection technique or the trocar technique. Complication rates are increased by the trocar technique. These complications have been broadly classified as either technical or infective. Technical causes include tube malposition, blocked drain, chest drain dislodgement, reexpansion pulmonary edema, subcutaneous emphysema, nerve injuries, cardiac and vascular injuries, oesophageal injuries, residual/postextubation pneumothorax, fistulae, tumor recurrence at insertion site, herniation through the site of thoracostomy, chylothorax, and cardiac dysrhythmias. Infective complications include empyema and surgical site infection. Conclusion. Tube thoracostomy, though commonly performed is not without risk. Blunt dissection technique has lower risk of complications and is hence recommended.

  4. Tube Thoracostomy: Complications and Its Management

    Science.gov (United States)

    Kesieme, Emeka B.; Dongo, Andrew; Ezemba, Ndubueze; Irekpita, Eshiobo; Jebbin, Nze; Kesieme, Chinenye

    2012-01-01

    Background. Tube thoracostomy is widely used throughout the medical, surgical, and critical care specialities. It is generally used to drain pleural collections either as elective or emergency. Complications resulting from tube thoracostomy can occasionally be life threatening. Aim. To present an update on the complications and management of complications of tube thoracostomy. Methods. A review of the publications obtained from Medline search, medical libraries, and Google on tube thoracostomy and its complications was done. Results. Tube thoracostomy is a common surgical procedure which can be performed by either the blunt dissection technique or the trocar technique. Complication rates are increased by the trocar technique. These complications have been broadly classified as either technical or infective. Technical causes include tube malposition, blocked drain, chest drain dislodgement, reexpansion pulmonary edema, subcutaneous emphysema, nerve injuries, cardiac and vascular injuries, oesophageal injuries, residual/postextubation pneumothorax, fistulae, tumor recurrence at insertion site, herniation through the site of thoracostomy, chylothorax, and cardiac dysrhythmias. Infective complications include empyema and surgical site infection. Conclusion. Tube thoracostomy, though commonly performed is not without risk. Blunt dissection technique has lower risk of complications and is hence recommended. PMID:22028963

  5. Study of two novel large-field-of-view image intensifiers versus conventional chest radiography with use of FROC methods and simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Van Waes, P.F.G.M.; Puylaert, C.B.A.J.

    1989-01-01

    Two novel large-field-of-view image intensifier (LFOV 1.1) tubes have been introduced whose image area makes them suitable for chest imaging. Both modalities present a 100-mm hard-copy image to the radiologist. A pulmonary nodule performance experiment was done to compare the diagnostic accuracy of these tubes with conventional full-size chest images. The data were analyzed with the maximum-likelihood FROCFIT program. The relative ranking in terms of decreasing A1 values was TLX, Siemens 43-cm mode, conventional radiography, and Siemens 57-cm mode

  6. Prevalence and Diagnostic Performance of Isolated and Combined NEXUS Chest CT Decision Criteria.

    Science.gov (United States)

    Raja, Ali S; Mower, William R; Nishijima, Daniel K; Hendey, Gregory W; Baumann, Brigitte M; Medak, Anthony J; Rodriguez, Robert M

    2016-08-01

    The use of chest computed tomography (CT) to evaluate emergency department patients with adult blunt trauma is rising. The NEXUS Chest CT decision instruments are highly sensitive identifiers of adult blunt trauma patients with thoracic injuries. However, many patients without injury exhibit one of more of the criteria so cannot be classified "low risk." We sought to determine screening performance of both individual and combined NEXUS Chest CT criteria as predictors of thoracic injury to inform chest CT imaging decisions in "non-low-risk" patients. This was a secondary analysis of data on patients in the derivation and validation cohorts of the prospective, observational NEXUS Chest CT study, performed September 2011 to May 2014 in 11 Level I trauma centers. Institutional review board approval was obtained at all study sites. Adult blunt trauma patients receiving chest CT were included. The primary outcome was injury and major clinical injury prevalence and screening performance in patients with combinations of one, two, or three of seven individual NEXUS Chest CT criteria. Across the 11 study sites, rates of chest CT performance ranged from 15.5% to 77.2% (median = 43.6%). We found injuries in 1,493/5,169 patients (28.9%) who had chest CT; 269 patients (5.2%) had major clinical injury (e.g., pneumothorax requiring chest tube). With sensitivity of 73.7 (95% confidence interval [CI] = 68.1 to 78.6) and specificity of 83.9 (95% CI = 83.6 to 84.2) for major clinical injury, abnormal chest-x-ray (CXR) was the single most important screening criterion. When patients had only abnormal CXR, injury and major clinical injury prevalences were 60.7% (95% CI = 52.2% to 68.6%) and 12.9% (95% CI = 8.3% to 19.4%), respectively. Injury and major clinical injury prevalences when any other single criterion alone (other than abnormal CXR) was present were 16.8% (95% CI = 15.2% to 18.6%) and 1.1% (95% CI = 0.1% to 1.8%), respectively. Injury and major clinical injury prevalences

  7. A preliminary stability analysis of MYRRHA Primary Heat Exchanger two-phase tube bundle

    Energy Technology Data Exchange (ETDEWEB)

    Castelliti, Diego [Studiecentrum voor kernenergie – Centre d’étude de l’énergie nucléaire (SCK-CEN), Boeretang 200, Mol (Belgium); GeNERG – DIME/TEC, University of Genova, Via all’Opera Pia 15/a, 16145 Genova (Italy); Lomonaco, Guglielmo, E-mail: guglielmo.lomonaco@unige.it [GeNERG – DIME/TEC, University of Genova, Via all’Opera Pia 15/a, 16145 Genova (Italy); INFN, Via Dodecaneso 33, 16146 Genova (Italy)

    2016-08-15

    Highlights: • MYRRHA is a pool-type LBE-cooled ADS, operable also as a critical reactor. • MYRRHA is a high priority infrastructure for nuclear research in Europe. • PHX (primary side: LBE, secondary side: two-phase water), is a MYRRHA key component. • The original MYRRHA PHX design does not offer a fully satisfying response to DWO. • The adoption of an orifice allows extending considerably the stability of MYRRHA PHX. - Abstract: The MYRRHA (Multi-purpose hYbrid Research Reactor for High-tech Applications) project, started at SCK·CEN since 1999, aims at the construction of a pool-type sub-critical Accelerator-Driven System (ADS) which could also operate as a critical reactor. The primary system, enclosed in the primary vessel, is filled with Lead Bismuth Eutectic (LBE) which acts as primary coolant. The power is then delivered through four heat exchangers to four secondary loops. The secondary cooling fluid is two-phase water operating at relatively low pressure (16 bar). Four aero-condensers act as heat sinks, since MYRRHA design does not foresee any electricity generation. The MYRRHA Primary Heat eXchangers (PHXs) cover a role of fundamental importance in normal operation and accidental conditions, being part of the primary and secondary cooling system and of the Decay Heat Removal (DHR) system. It is thus highly relevant to understand the PHXs behavior under all the potential working conditions. In particular, the stability of the PHXs must be guaranteed under all operating conditions. System code models play an important role in understanding and predicting the behavior of the reactor in all conditions, from steady state to operational and accidental transients, and simulating all the postulated scenarios. A solid PHX design requires a complete assessment of two-phase flow instabilities in the secondary system water tube bundle and the potential implementation of a suitable stabilizing device (orifice) to reduce the impact of the perturbations along

  8. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    OpenAIRE

    Livingstone Roshan; Pradip Joe; Dinakran Paul; Srikanth B

    2010-01-01

    Objective: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tu...

  9. Nurses’ knowledge of care of chest drain: A survey in a Nigerian semiurban university hospital

    Science.gov (United States)

    Kesieme, Emeka Blessius; Essu, Ifeanyichukwu Stanley; Arekhandia, Bruno Jeneru; Welcker, Katrin; Prisadov, Georgi

    2016-01-01

    Background/Objective: Inefficient nursing care of chest drains may associated with unacceptable and sometimes life-threatening complications. This report aims to ascertain the level of knowledge of care of chest drains among nurses working in wards in a teaching hospital in Nigeria. Methods: A cross-sectional study among nurses at teaching hospital using pretested self-administered questionnaires. Results: The majority were respondents aged between 31 and 40 years (45.4%) and those who have nursing experience between 6 and 10 years. Only 37 respondents (26.2%) had a good knowledge of nursing care of chest drains. Knowledge was relatively higher among nurses who cared for chest drains daily, nurses who have a work experience of 0.05). Performance was poor on the questions on position of drainage system were not statistically significant with relationship to waist level while mobilizing the patient, application of suction to chest drains, daily changing of dressing over chest drain insertion site, milking of tubes and drainage system with dependent loop. Conclusion: The knowledge of care of chest drains among nurses is poor, especially in the key post procedural care. There is an urgent need to train them so as to improve the nursing care of patients managed with chest drains. PMID:26857934

  10. Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study

    International Nuclear Information System (INIS)

    Shan, Jing; Lee, Yueh Z; Lu, Jianping; Zhou, Otto; Tucker, Andrew W; Heath, Michael D; Wang, Xiaohui; Foos, David H

    2015-01-01

    Chest tomosynthesis is a low-dose, quasi-3D imaging modality that has been demonstrated to improve the detection sensitivity for small lung nodules, compared to 2D chest radiography. The purpose of this study is to investigate the feasibility and system requirements of stationary chest tomosynthesis (s-DCT) using a spatially distributed carbon nanotube (CNT) x-ray source array, where the projection images are collected by electronically activating individual x-ray focal spots in the source array without mechanical motion of the x-ray source, detector, or the patient. A bench-top system was constructed using an existing CNT field emission source array and a flat panel detector. The tube output, beam quality, focal spot size, system in-plane and in-depth resolution were characterized. Tomosynthesis slices of an anthropomorphic chest phantom were reconstructed for image quality assessment. All 75 CNT sources in the source array were shown to operate reliably at 80 kVp and 5 mA tube current. Source-to-source consistency in the tube current and focal spot size was observed. The incident air kerma reading per mAs was measured as 74.47 uGy mAs −1 at 100 cm. The first half value layer of the beam was 3 mm aluminum. An average focal spot size of 2.5  ×  0.5 mm was measured. The system MTF was measured to be 1.7 cycles mm −1 along the scanning direction, and 3.4 cycles mm −1 perpendicular to the scanning direction. As the angular coverage of 11.6°–34°, the full width at half maximum of the artifact spread function improved greatly from 9.5 to 5.2 mm. The reconstructed tomosynthesis slices clearly show airways and pulmonary vascular structures in the anthropomorphic lung phantom. The results show the CNT source array is capable of generating sufficient dose for chest tomosynthesis imaging. The results obtained so far suggest an s-DCT using a distributed CNT x-ray source array is feasible. (paper)

  11. Image quality of a Konica Regius 336 digital system in chest radiography

    International Nuclear Information System (INIS)

    Ostinelli, A.; Frigerio, M.; Monti, A.F.; Gelosa, S.; Tognoli, P.; Perniola, N.; Gozzi, G.

    2000-01-01

    Digital radiographic systems permit to optimize execution, depiction and storage of radiological images. Since a Regius 336 digital system (Konica Corp. Tokyo, Japan) devoted to chest radiography Department of S. Anna Hospital in Como, Italy, it was investigated its performance relative to image quality. Konica Regius 336 is a computed radiography system made of a phosphorescence detector plate which is scanned with an infrared semiconductor laser beam. The radiographic image obtained from the detector is subjected to image processing, which allows a stable output and the nonlinear curve typical of conventional radiographic systems. Image quality was assessed based on the following parameters: dose, contrast, noise and spatial resolution. As reference, it was assessed the same parameters on a Cronex 88 analogic chest-changer (DuPont Pharma, North Billerica, Mass, USA). The Regius 336 air kerma values were always higher than the analogic ones (about 10%), both with and without a chest phantom; noise was also greater than in analogic images, sometimes even doubled. The optical densities of a step wedge and the spatial resolution of the digital chest-changer are independent of the X-ray tube voltage consequent to broader optical latitude. Inversely, the analogic images of the wedges show great optical density variability as a function of the X-ray tube voltage (in a range of 2). The modulation transfer functions of the two systems have the same trend. The performance of the Konica Regius 336 is nearly equivalent to that of an analogic system. The main advantages of the digital system are a standard output, lower consumption of radiographic films, higher productiveness and better image quality standard level [it

  12. Primary Adenocarcinoma of the fallopian tube: Case Report

    Directory of Open Access Journals (Sweden)

    Mert Kazandi

    2010-10-01

    Full Text Available Carcinoma of the follapian tube accounts for only 0.3 to 1.1% of all gynecologic malignancies. Primer carsinoma of follapian tube is a rare and aggressive cancer. It is not diagnosed until at an advanced stage. Because its epidemiologic, biologic and prognostic characteristics arent well known, no standart treatment has been developed. Most of them are adenocarcinomas. Stage is significant prognostic factor. Typical clinical symptoms are vaginal bleeding, watery discharge and pelvic pain. Tubal carsinomas are treated with surgical and chemotherapeutic approach as epithelial ovarian cancer. We reported a 76 year-old woman with primer fallopian tube carcinomas. The case presented with postmenopausal vaginal bleeding. Endometrial curettage showed no abnormal findings. However, we performed laparotomy because of ongoing vaginal bleeding after currettage and left adnexal mass. In the laparotomy, left tube was observed hydropic. The histopathologic result of the left tube revealed primer fallopian tube adenocarcinoma. We performed hysterectomy and bilateral salpingo-oophorectomy. She has been given chemotherapy (endoxan-carboplatin treatment for 4 mounths.

  13. Practical applications of digital tomosynthesis of the chest.

    Science.gov (United States)

    Galea, A; Durran, A; Adlan, T; Gay, D; Riordan, R; Dubbins, P; Williams, M P

    2014-04-01

    Digital tomosynthesis is a radiographic technique that generates a number of coronal raw images of a patient from a single pass of the x-ray tube. Tomosynthesis provides some of the tomographic benefits of computed tomography (CT), but at a much lower dose of radiation and cost when compared to CT. This review illustrates the range of practical applications of digital tomosynthesis of the chest. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Influence of the centrifuge time of primary plasma tubes on routine coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Manzato, Franco; Guidi, Gian Cesare

    2007-07-01

    Preparation of blood specimens is a major bottleneck in the laboratory throughput. Reliable strategies for reducing the time required for specimen processing without affecting quality should be acknowledged, especially for laboratories performing stat analyses. The present investigation was planned to establish a minimal suitable centrifuge time for primary samples collected for routine coagulation testing. Five sequential primary vacuum tubes containing 0.109 mol/l buffered trisodium citrate were collected from 10 volunteers and were immediately centrifuged on a conventional centrifuge at 1500 x g, at room temperature for 1, 2, 5, 10 and 15 min, respectively. Hematological and routine coagulation testing, including prothrombin time, activated partial thromboplastin time and fibrinogen, were performed. The centrifugation time was inversely associated with residual blood cell elements in plasma, especially platelets. Statistically significant variations from the reference 15-min centrifuge specimens were observed for fibrinogen in samples centrifuged for 5 min at most and for the activated partial thromboplastin time in samples centrifuged for 2 min at most. Meaningful biases related to the desirable bias were observed for fibrinogen in samples centrifuged for 2 min at most, and for the activated partial thromboplastin time in samples centrifuged for 1 min at most. According to our experimental conditions, a 5-10 min centrifuge time at 1500 x g may be suitable for primary tubes collected for routine coagulation testing.

  15. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  16. Chest radiography practice in critically ill patients: a postal survey in the Netherlands

    International Nuclear Information System (INIS)

    Graat, Marleen E; Hendrikse, Karin A; Spronk, Peter E; Korevaar, Johanna C; Stoker, Jaap; Schultz, Marcus J

    2006-01-01

    To ascertain current chest radiography practice in intensive care units (ICUs) in the Netherlands. Postal survey: a questionnaire was sent to all ICUs with > 5 beds suitable for mechanical ventilation; pediatric ICUs were excluded. When an ICU performed daily-routine chest radiographs in any group of patients it was considered to be a 'daily-routine chest radiography' ICU. From the number of ICUs responding, 63% practice a daily-routine strategy, in which chest radiographs are obtained on a daily basis without any specific reason. A daily-routine chest radiography strategy is practiced less frequently in university-affiliated ICUs (50%) as compared to other ICUs (68%), as well as in larger ICUs (> 20 beds, 50%) as compared to smaller ICUs (< 20 beds, 65%) (P > 0.05). Remarkably, physicians that practice a daily-routine strategy consider daily-routine radiographs helpful in guiding daily practice in less than 30% of all performed radiographs. Chest radiographs are considered essential for verification of the position of invasive devices (81%) and for diagnosing pneumothorax, pneumonia or acute respiratory distress syndrome (82%, 74% and 69%, respectively). On demand chest radiographs are obtained after introduction of thoracic drains, central venous lines and endotracheal tubes in 98%, 84% and 75% of responding ICUs, respectively. Chest films are also obtained in case of ventilatory deterioration (49% of responding ICUs), and after cardiopulmonary resuscitation (59%), tracheotomy (58%) and mini-tracheotomy (23%). There is notable lack of consensus on chest radiography practice in the Netherlands. This survey suggests that a large number of intensivists may doubt the value of daily-routine chest radiography, but still practice a daily-routine strategy

  17. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    International Nuclear Information System (INIS)

    Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J; Cagnon, Christopher H; Goldin, Jonathan G; McNitt-Gray, Michael F; Primak, Andrew N; McCollough, Cynthia H; Stevens, Donna M; Cody, Dianna D

    2009-01-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  18. Efficacy of short-term versus long-term chest tube drainage following talc slurry pleurodesis in patients with malignant pleural effusions: a randomised trial.

    Science.gov (United States)

    Goodman, Anna; Davies, Christopher W H

    2006-10-01

    Talc pleurodesis is commonly used in the palliative treatment of malignant pleural effusions but the shortest and most effective regime has not been determined. In particular, it is not clear when the intercostal drain should be removed following the insertion of sclerosant. We conducted a single-centre, randomised, open trial of drain removal at 24 h versus 72 h following talc slurry pleurodesis. The primary outcome measure was success of pleurodesis (no recurrence of effusion on chest radiograph at 1-month follow-up) and secondary outcome measures included length of hospital stay and mortality. We found no difference between recurrence of pleural effusion in those randomised to drain removal at 24 h and those randomised to drain removal at 72 h (p>0.5). However, length of stay was significantly reduced when the chest drain was removed at 24 h (4 days versus 8 days; p<0.01). Mortality did not differ between the two groups. We conclude that this shorter pleurodesis regime is safe and effective.

  19. Interpretation of chest radiographs with a high-resolution (2,000 x 2,000 x 12 bit) display

    International Nuclear Information System (INIS)

    Cox, G.G.

    1989-01-01

    This paper presents an evaluation of high-resolution (2K x 2Kx 12 bit) display for interpretation of chest radiographs. Three radiologists chose a total of 165 chest radiographs to ensure representation of nine signs: apical pleural scarring, chronic obstructive pulmonary disease, interstitial processes, atelectasis, pneumothorax, hilar mass, pleural effusion, pneumonia, and nodules. Each chest film was digitized to 4Kx 4Kx 12 bit and averaged to 2Kx 2Kx 12 bit and printed on a laser film printer. The 2K x 2K x 12-bit images were displayed and interactively windowed on a 2K x 2K x 12-bit high-resolution gray-scale cathode ray tube display. Six radiologists, none of whom participated in the case selection process, then interpreted a mixture of the screen film chest radiographs, the laser printed 2K chest radiographs, and the high resolution displayed 2K images

  20. Diet and Physical Activity Change or Usual Care in Improving Progression-Free Survival in Patients With Previously Treated Stage II, III, or IV Ovarian, Fallopian Tube, or Primary Peritoneal Cancer

    Science.gov (United States)

    2018-02-14

    Fallopian Tube Clear Cell Adenocarcinoma; Fallopian Tube Endometrioid Adenocarcinoma; Fallopian Tube Mucinous Adenocarcinoma; Fallopian Tube Serous Adenocarcinoma; Fallopian Tube Transitional Cell Carcinoma; Malignant Ovarian Brenner Tumor; Ovarian Clear Cell Adenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Adenocarcinoma; Ovarian Seromucinous Carcinoma; Ovarian Serous Adenocarcinoma; Ovarian Transitional Cell Carcinoma; Primary Peritoneal Serous Adenocarcinoma; Stage IIA Fallopian Tube Cancer AJCC v6 and v7; Stage IIA Ovarian Cancer AJCC V6 and v7; Stage IIB Fallopian Tube Cancer AJCC v6 and v7; Stage IIB Ovarian Cancer AJCC v6 and v7; Stage IIC Fallopian Tube Cancer AJCC v6 and v7; Stage IIC Ovarian Cancer AJCC v6 and v7; Stage IIIA Fallopian Tube Cancer AJCC v7; Stage IIIA Ovarian Cancer AJCC v6 and v7; Stage IIIA Primary Peritoneal Cancer AJCC v7; Stage IIIB Fallopian Tube Cancer AJCC v7; Stage IIIB Ovarian Cancer AJCC v6 and v7; Stage IIIB Primary Peritoneal Cancer AJCC v7; Stage IIIC Fallopian Tube Cancer AJCC v7; Stage IIIC Ovarian Cancer AJCC v6 and v7; Stage IIIC Primary Peritoneal Cancer AJCC v7; Stage IV Fallopian Tube Cancer AJCC v6 and v7; Stage IV Ovarian Cancer AJCC v6 and v7; Stage IV Primary Peritoneal Cancer AJCC v7; Undifferentiated Fallopian Tube Carcinoma; Undifferentiated Ovarian Carcinoma

  1. Radiological diagnosis of chest wall tuberculosis: CT versus chest radiograph

    International Nuclear Information System (INIS)

    Liu Fugeng; Pan Jishu; Chen Qihang; Zhou Cheng; Yu Jingying; Tang Dairong

    2006-01-01

    Objective: To evaluate the role of CT or Chest radiograph in diagnosis of chest wall tuberculosis. Methods: The study population included 21 patients with chest wall tuberculosis confirmed by operation or biopsy. Chest radiograph and plain CT were performed in all eases, while enhanced CT in 9 cases, and all images were reviewed by 2 radiologists. Results: Single soft tissue mass of the chest wall was detected in all cases on CT, but not on chest radiograph(χ 2 =42.000, P 2 =4.421, P<0.05). Conclusion: CT, especially enhanced CT scan is the first choice in the diagnosis of chest wall tuberculosis. (authors)

  2. Chest Wall tumor: combined management

    International Nuclear Information System (INIS)

    Rao Bhaskar, N.

    1997-01-01

    Cancer is relatively rare disease among children and adolescents. The incidence of solid tumors other than CNS is less than 2/100,000. Tumors of the chest wall can arise either from the somatic tissue or ribs. These are rare, so either institutional reviews or multi institutional studies should determine optimal therapeutic management. Of the bony chest wall, Ewing's sarcoma or the family of tumor (peripheral neuro epithelioma, Askin tumor), are the most common. These lesions are lytic and have associated large extra pleural component. This large extra pleural component often necessitates major chest wall resection (3 or more ribs), and when lower ribs are involved, this entails resection of portion of diaphragm. Despite this resection, survival in the early 1970 was 10-20%. Since 1970 multi agent chemotherapy has increased survival rates. of importance, however, is these regimens have caused significant reduction of these extra pleural components so that major chest wall resections have become a rarity. With improved survival and decreased morbidity preoperative chemotherapy followed by surgery is now the accepted modality of treatment. Another major advantage of this regimen is that potential radiation therapy may be obviated. The most common chest wall lesion is rhabdomyosarcoma. In the IRS study of 1620 RMS patients, in 141 (9%) the primary lesion was in the chest wall. these are primarily alveolar histology. when lesions were superficial, wide local excision with supplemental radiation therapy was associated with low morbidity and good overall survival. however, a majority have significant intra- thoracic components. in these circumstances the resectability rate is less than 30% and the survival poor. Other lesions include non rhabdomyosarcomas, eosinophilic granuloma, chondrosarcoma, and osteomyelitis. The management of these lesions varies according to extent, histology, and patient characteristics

  3. Tracheal rupture after misplacement of Sengstaken-Blakemore tube ...

    African Journals Online (AJOL)

    The balloon were immediately deflated and a chest X-ray was performed, showing the tube in the right bronchus airway (A), so it was withdrawn. Right pneumothorax appeared and was treated with an intercostal drainage. The patient required orotracheal intubation and a CT scan was performed to show the rupture level ...

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  5. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  6. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  7. Spontaneous Recanalization of the Obstructed Right Coronary Artery Caused by Blunt Chest Trauma.

    Science.gov (United States)

    Haraguchi, Yumiko; Sakakura, Kenichi; Yamamoto, Kei; Taniguchi, Yousuke; Nakashima, Ikue; Wada, Hiroshi; Sanui, Masamitsu; Momomura, Shin-Ichi; Fujita, Hideo

    2018-03-30

    Blunt chest trauma can cause a wide variety of injuries including acute myocardial infarction (AMI). Although AMI due to coronary artery dissection caused by blunt chest trauma is very rare, it is associated with high morbidity and mortality. In the vast majority of patients with AMI, primary percutaneous coronary interventions (PCI) are performed to recanalize obstructed arteries, but PCI carries a substantial risk of hemorrhagic complications in the acute phase of trauma. We report a case of AMI due to right coronary artery (RCA) dissection caused by blunt chest trauma. The totally obstructed RCA was spontaneously recanalized with medical therapy. We could avoid primary PCI in the acute phase of blunt chest trauma because electrocardiogram showed early reperfusion signs. We performed an elective PCI in the subacute phase when the risk of bleeding subsided. Since the risk of severe hemorrhagic complications is greater in the acute phase of blunt chest trauma as compared with the late phase, deferring emergency PCI is reasonable if signs of recanalization are observed.

  8. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  11. FLAIL CHEST

    Directory of Open Access Journals (Sweden)

    Anton Crnjac

    2003-12-01

    Full Text Available Background. Major thoracic trauma is consistent with high mortality rate because of associated injuries of vital thoracic organs and dangerous complications. The flail chest occurs after disruption of the skeletal continuity of chest wall and demands because of its pathophysiological complexity rapid and accurate diagnosis and treatment.Conclusions. Basic pathophysiological mechanism of the flail chest is respiratory distress, which is provoked by pulmonary contusions and paradoxical chest wall motion. The treatment should be pointed to improvement and support of respiratory functions and include aggressive pain control, pulmonary physiotherapy and selective mechanical ventilation. Views about operative fixation of the flail chest are still controversial. Neither mortality rate neither long-term disability are improved after operative fixation.

  12. How early should VATS be performed for retained haemothorax in blunt chest trauma?

    Science.gov (United States)

    Lin, Hsing-Lin; Huang, Wen-Yen; Yang, Chyan; Chou, Shih-Min; Chiang, Hsin-I; Kuo, Liang-Chi; Lin, Tsung-Ying; Chou, Yi-Pin

    2014-09-01

    Blunt chest injury is not uncommon in trauma patients. Haemothorax and pneumothorax may occur in these patients, and some of them will develop retained pleural collections. Video-assisted thoracoscopic surgery (VATS) has become an appropriate method for treating these complications, but the optimal timing for performing the surgery and its effects on outcome are not clearly understood. In this study, a total of 136 patients who received VATS for the management of retained haemothorax from January 2003 to December 2011 were retrospectively enrolled. All patients had blunt chest injuries and 90% had associated injuries in more than two sites. The time from trauma to operation was recorded and the patients were divided into three groups: 2-3 days (Group 1), 4-6 days (Group 2), and 7 or more days (Group 3). Clinical outcomes such as the length of stay (LOS) at the hospital and intensive care unit (ICU), and duration of ventilator and chest tube use were all recorded and compared between groups. The mean duration from trauma to operation was 5.9 days. All demographic characteristics showed no statistical differences between groups. Compared with other groups, Group 3 had higher rates of positive microbial cultures in pleural collections and sputum, longer duration of chest tube insertion and ventilator use. Lengths of hospital and ICU stay in Groups 1 and 2 showed no statistical difference, but were longer in Group 3. The frequency of repeated VATS was lower in Group 1 but without statistically significant difference. This study indicated that an early VATS intervention would decrease chest infection. It also reduced the duration of ventilator dependency. The clinical outcomes were significantly better for patients receiving VATS within 3 days under intensive care. In this study, we suggested that VATS might be delayed by associated injuries, but should not exceed 6 days after trauma. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  14. Comparative evaluation of preventive measures against primary side stress corrosion cracking of mill annealed Inconel 600 steam generator tubes

    International Nuclear Information System (INIS)

    Frederick, G.; Hernalsteen, P.

    1986-01-01

    Significant amounts of primary side cracking have been reported in the mechanically expanded area of the tubes of PWR steam generators in Europe, in Japan and to a lesser extent in the USA. The Belgian utilities are faced with the same problem. At Doel 2, where the tubes are rolled for only a part of the tubesheet, primary side cracking appeared in the roll transition. The Doel 3 and Tihange 2 steam generators, whose tubes are expanded for the full depth of the tube sheet, have experienced cracking after about 10 000 h of operation not only in the roll transition but also at roll overlaps. While some leaks and eddy current indications are associated with tubesheet or rolling anomalies, many of them are found on normal tubes. A programme was launched by the Belgian utilities and was further co-sponsored by the Electric Power Research Institute (EPRI) to develop preventive actions applicable not only to hot steam generators but also to cold steam generators already installed on site. These preventive measures include stress relaxation and metallurgical improvement of the material by an in situ heat treatment of the whole tube sheet (a steam generator model was used to evaluate the feasibility of this treatment), and the introduction of residual compressive stresses on ID by rotopeening or shotpeening without inducing unacceptable tensile stresses on OD. A comparative evaluation of these measures was established on the basis of tests performed on representative mock-ups and specimens. (author)

  15. Chest physiotherapy in mechanically ventilated children: a review.

    Science.gov (United States)

    Krause, M F; Hoehn, T

    2000-05-01

    Many physicians, nurses, and respiratory care practitioners consider chest physiotherapy (CP) a standard therapy in mechanically ventilated children beyond the newborn period. CP includes percussion, vibration, postural drainage, assisted coughing, and suctioning via the endotracheal tube. We searched the medical literature by using the key words "chest physiotherapy" and "chest physical therapy" (among others) by means of the MEDLINE and Current Contents databases. Because of the paucity of objective data, we examined all reports dealing with this topic, including studies on adult patients. For data extraction, not enough material existed to perform a meta-analysis. Despite its widespread use, almost no literature dealing with this treatment modality in pediatric patients exists. Studies with mechanically ventilated pediatric and adult patients have shown that CP is the most irritating routine intensive care procedure to patients. An increase in oxygen consumption often occurs when a patient receives CP accompanied by an elevation in heart rate, blood pressure, and intracranial pressure. CP leads to short-term decreases in oxygen, partial pressure in the blood, and major fluctuations in cardiac output. Changes in these vital signs and other variables may be even more pronounced in pediatric patients because the lung of a child is characterized by a higher closing capacity and the chest walls are characterized by a much higher compliance, thus predisposing the child to the development of atelectasis secondary to percussion and vibration. CP in mechanically ventilated children may not be considered a standard therapy. Controlled studies examining the impact of CP on the duration of mechanical ventilatory support, critical illness, and hospital stay are needed.

  16. Traumatic chest injury in children: A single thoracic surgeon′s experience in two Nigerian tertiary hospitals

    Directory of Open Access Journals (Sweden)

    Kelechi Emmanuel Okonta

    2015-01-01

    Full Text Available Background: This study was to determine the extent and outcome of childhood chest injury in Nigeria, and to compare results with that of other literatures. Patients and Methods: A Prospective study of all children under 18 years of age with chest trauma in two tertiary hospitals in Southern Nigeria from January 2012 to December 2014 was reviewed. The aetiology, type, associated injury, mechanism, treatment and outcome were evaluated. The patients were followed up in the clinic. The data were analysed using SPSS version 20.0 with a significant P 12-h versus 2 who presented <12-h and 6 of children between 0 and 9 years versus 3 at 10-18 years of age had empyema thoracis (P value not significant. One death was recorded. Conclusion: Chest trauma in children is still not common, and blunt chest injury from falls and automobile accidents are more common than penetrating chest injury. Treatment with tube thoracostomy is the major management modality with empyema thoracis as the most common complication.

  17. Failure rate of prehospital chest decompression after severe thoracic trauma.

    Science.gov (United States)

    Kaserer, Alexander; Stein, Philipp; Simmen, Hans-Peter; Spahn, Donat R; Neuhaus, Valentin

    2017-03-01

    Chest decompression can be performed by different techniques, like needle thoracocentesis (NT), lateral thoracostomy (LT), or tube thoracostomy (TT). The aim of this study was to report the incidence of prehospital chest decompression and to analyse the effectiveness of these techniques. In this retrospective case series study, all medical records of adult trauma patients undergoing prehospital chest decompression and admitted to the resuscitation area of a level-1 trauma center between 2009 and 2015 were reviewed and analysed. Only descriptive statistics were applied. In a 6-year period 24 of 2261 (1.1%) trauma patients had prehospital chest decompression. Seventeen patients had NT, six patients TT, one patient NT as well as TT, and no patients had LT. Prehospital successful release of a tension pneumothorax was reported by the paramedics in 83% (5/6) with TT, whereas NT was effective in 18% only (3/17). In five CT scans all thoracocentesis needles were either removed or extrapleural, one patient had a tension pneumothorax, and two patients had no pneumothorax. No NT or TT related complications were reported during hospitalization. Prehospital NT or TT is infrequently attempted in trauma patients. Especially NT is associated with a high failure rate of more than 80%, potentially due to an inadequate ratio between chest wall thickness and catheter length as previously published as well as a possible different pathophysiological cause of respiratory distress. Therefore, TT may be considered already in the prehospital setting to retain sufficient pleural decompression upon admission. Copyright © 2016. Published by Elsevier Inc.

  18. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  19. Evaluation of entrance surface air kerma in pediatric chest radiography

    International Nuclear Information System (INIS)

    Porto, L.; Lunelli, N.; Paschuk, S.; Oliveira, A.; Ferreira, J.L.; Schelin, H.; Miguel, C.; Denyak, V.; Kmiecik, C.; Tilly, J.; Khoury, H.

    2014-01-01

    The objective of this study was to evaluate the entrance surface air kerma in pediatric chest radiography. An evaluation of 301 radiographical examinations in anterior–posterior (AP) and posterior–anterior (PA) (166 examinations) and lateral (LAT) (135 examinations) projections was performed. The analyses were performed on patients grouped by age; the groups included ages 0–1 y, 1–5 y, 5–10 y, and 10–15 y. The entrance surface air kerma was determined with DoseCal software (Radiological Protection Center of Saint George's Hospital, London) and thermoluminescent dosimeters. Two different exposure techniques were compared. The doses received by patients who had undergone LAT examinations were 40% higher, on average, those in AP/PA examinations because of the difference in tube voltage. A large high-dose “tail” was observed for children up to 5 y old. An increase in tube potential and corresponding decrease in current lead to a significant dose reduction. The difference between the average dose values for different age ranges was not practically observed, implying that the exposure techniques are still not optimal. Exposure doses received using the higher tube voltage and lower current-time product correspond to the international diagnostic reference levels. - Highlights: • The entrance surface air kerma of chest X-ray examinations in pediatric patients was estimated. • The data were analyzed for patients aged up to 15 y, stratified by age. • The doses of LAT examinations were 40% higher than of AP/PA because of kV used. • An increase in kV with a decrease in mAs leads to significant dose reduction

  20. Large-field image intensifiers versus conventional chest radiography: ROC study with simulated interstitial disease

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Waes, P.F.G.M.

    1988-01-01

    Two image intensifier tubes have recently been introduced whose large imaging area makes them suitable for chest imaging (Phillips Pulmodiagnost TLX slit II and Siemens TX 57 large entrance field II). Both modalities present a 10 x 10-cm hard copy image to the radiologist. A receiver operating characteristic (ROC) curve study with simulated interstitial disease was performed to compare the image quality of these image intensifiers with conventional chest images. The relative ranking in terms of decreasing ROC areas was Siemens, conventional, and Philips. Compared with conventional imaging, none of the differences in ROC curve area were statistically significant at the 5% level

  1. Gender bias revisited: new insights on the differential management of chest pain

    Directory of Open Access Journals (Sweden)

    Karatolios Konstantinos

    2011-06-01

    Full Text Available Abstract Background Chest pain is a common complaint and reason for consultation in primary care. Few data exist from a primary care setting whether male patients are treated differently than female patients. We examined whether there are gender differences in general physicians' (GPs initial assessment and subsequent management of patients with chest pain, and how these differences can be explained Methods We conducted a prospective study with 1212 consecutive chest pain patients. The study was conducted in 74 primary care offices in Germany from October 2005 to July 2006. After a follow up period of 6 months, an independent interdisciplinary reference panel reviewed clinical data of every patient and decided about the etiology of chest pain at the time of patient recruitment (delayed type-reference standard. We adjusted gender differences of six process indicators for different models. Results GPs tended to assume that CHD is the cause of chest pain more often in male patients and referred more men for an exercise test (women 4.1%, men 7.3%, p = 0.02 and to the hospital (women 2.9%, men 6.6%, p Conclusions While observed gender differences can not be explained by differences in age, CHD prevalence, and underlying risk factors, the less typical symptom presentation in women might be an underlying factor. However this does not seem to result in suboptimal management in women but rather in overuse of services for men. We consider our conclusions rather hypothesis generating and larger studies will be necessary to prove our proposed model.

  2. A Monte Carlo-based model for simulation of digital chest tomo-synthesis

    International Nuclear Information System (INIS)

    Ullman, G.; Dance, D. R.; Sandborg, M.; Carlsson, G. A.; Svalkvist, A.; Baath, M.

    2010-01-01

    The aim of this work was to calculate synthetic digital chest tomo-synthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to correspond to the VolumeRAD chest tomo-synthesis system from GE Healthcare. Sixty tomo-synthesis projections were calculated with projection angles ranging from + 15 to -15 deg. The images from primary photons were calculated using an analytical model of the anti-scatter grid and a pre-calculated detector response function. The contributions from scattered photons were calculated using an in-house Monte Carlo-based model employing a number of variance reduction techniques such as the collision density estimator. Tomographic section images were reconstructed by transferring the simulated projections into the VolumeRAD system. The reconstruction was performed for three types of images using: (i) noise-free primary projections, (ii) primary projections including contributions from scattered photons and (iii) projections as in (ii) with added correlated noise. The simulated section images were compared with corresponding section images from projections taken with the real, anthropomorphic phantom from which the digital voxel phantom was originally created. The present article describes a work in progress aiming towards developing a model intended for optimisation of chest tomo-synthesis, allowing for simulation of both existing and future chest tomo-synthesis systems. (authors)

  3. Challenges in management of pediatric life-threatening neck and chest trauma

    Directory of Open Access Journals (Sweden)

    Shilpa Sharma

    2018-01-01

    Full Text Available Introduction: Neck and thoracic trauma in children pose unforeseen challenges requiring variable management strategies. Here, we describe some unusual cases. Patients and Methods: Pediatric cases of unusual neck and thoracic trauma prospectively managed from April 2012 to March 2014 at a Level 1 trauma center were studied for management strategies, outcome, and follow-up. Results: Six children with a median age of 5.5 (range 2–10 years were managed. Mechanism of injury was road traffic accident, fall from height and other accidental injury in 2, 3 and 1 patient respectively. The presentation was respiratory distress and quadriplegia, exposed heart, penetrating injury in neck, dysphagia and dyspnea, and swelling over the chest wall in 1, 1, 1, 2 and 1 cases respectively. Injuries included lung laceration, open chest wall, vascular injury of the neck, tracheoesophageal fistula (2, and chest wall posttraumatic pyomyositis. One patient had a flare of miliary tuberculosis. Immediate management included chest wall repair; neck exploration and repair, esophagostomy, gastroesophageal stapling, and feeding jejunostomy (followed by gastric pull-up 8 months later. Chest tube insertion and total parenteral nutrition was required in one each. 2 and 4 patients required tracheostomy and mechanical ventilation. The patient with gastric pull-up developed a stricture of the esophagogastric anastomosis that was revised at 26-month follow-up. At follow-up of 40–61 months, five patients are well. One patient with penetrating neck injury suffered from blindness due to massive hemorrhage from the vascular injury in the neck and brain ischemia with only peripheral vision recovery. Conclusion: Successful management of neck and chest wall trauma requires timely appropriate decisions with a team effort.

  4. Chest trauma in children, single center experience.

    Science.gov (United States)

    Ismail, Mohamed Fouad; al-Refaie, Reda Ibrahim

    2012-10-01

    Trauma is the leading cause of mortality in children over one year of age in industrialized countries. In this retrospective study we reviewed all chest trauma in pediatric patients admitted to Mansoura University Emergency Hospital from January 1997 to January 2007. Our hospital received 472 patients under the age of 18. Male patients were 374 with a mean age of 9.2±4.9 years. Causes were penetrating trauma (2.1%) and blunt trauma (97.9%). The trauma was pedestrian injuries (38.3%), motor vehicle (28.1%), motorcycle crash (19.9%), falling from height (6.7%), animal trauma (2.9%), and sports injury (1.2%). Type of injury was pulmonary contusions (27.1%) and lacerations (6.9%), rib fractures (23.9%), flail chest (2.5%), hemothorax (18%), hemopneumothorax (11.8%), pneumothorax (23.7%), surgical emphysema (6.1%), tracheobronchial injury (5.3%), and diaphragm injury (2.1%). Associated lesions were head injuries (38.9%), bone fractures (33.5%), and abdominal injuries (16.7%). Management was conservative (29.9%), tube thoracostomy (58.1%), and thoracotomy (12.1%). Mortality rate was 7.2% and multiple trauma was the main cause of death (82.3%) (Ptrauma is the most common cause of pediatric chest trauma and often due to pedestrian injuries. Rib fractures and pulmonary contusions are the most frequent injuries. Delay in diagnosis and multiple trauma are associated with high incidence of mortality. Copyright © 2011 SEPAR. Published by Elsevier España, S.L. All rights reserved.

  5. Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Conclusion: Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

  6. Diagnosing pulmonary edema: lung ultrasound versus chest radiography.

    Science.gov (United States)

    Martindale, Jennifer L; Noble, Vicki E; Liteplo, Andrew

    2013-10-01

    Diagnosing the underlying cause of acute dyspnea can be challenging. Lung ultrasound may help to identify pulmonary edema as a possible cause. To evaluate the ability of residents to recognize pulmonary edema on lung ultrasound using chest radiographs as a comparison standard. This is a prospective, blinded, observational study of a convenience sample of resident physicians in the Departments of Emergency Medicine (EM), Internal Medicine (IM), and Radiology. Residents were given a tutorial on interpreting pulmonary edema on both chest radiograph and lung ultrasound. They were then shown both ultrasounds and chest radiographs from 20 patients who had presented to the emergency department with dyspnea, 10 with a primary diagnosis of pulmonary edema, and 10 with alternative diagnoses. Cohen's κ values were calculated to describe the strength of the correlation between resident and gold standard interpretations. Participants included 20 EM, 20 IM, and 20 Radiology residents. The overall agreement with gold standard interpretation of pulmonary edema on lung ultrasound (74%, κ = 0.51, 95% confidence interval 0.46-0.55) was superior to chest radiographs (58%, κ = 0.25, 95% confidence interval 0.20-0.30) (P Radiology residents interpreted chest radiographs more accurately than did EM and IM residents. Residents were able to more accurately identify pulmonary edema with lung ultrasound than with chest radiograph. Physicians with minimal exposure to lung ultrasound may be able to correctly recognize pulmonary edema on lung ultrasound.

  7. Primary carcinoma of fallopian tubes in the material of the Institute of Oncology in Gliwice

    Energy Technology Data Exchange (ETDEWEB)

    Franek, K; Zielonka, I; Kwasniewska-Rokicinska, C [Instytut Onkologii, Gliwice (Poland)

    1976-01-01

    The survival of 17 patients treated with postoperative radiotherapy at the Institute of Oncology in Gliwice for primary fallopian tube carcinoma is analysed. The causes of therapeutic failures and short survival (within 2 years) were - too far advanced disease at the time of main treatment which was due to diagnostic difficulties and too late reference of patients for surgery.

  8. Protocol optimization in chest CT scans of child

    Energy Technology Data Exchange (ETDEWEB)

    Abrao L, L. T.; Amaral de O, F.; Prata M, A. [Biomedical Engineering Center, Centro Federal de Educacao Tecnologica de Minas Gerais, 30421-169, Belo Horizonte, Minas Gerais (Brazil); Bustos F, M., E-mail: luanaabrao@gmail.com [Universidad Federal de Minas Gerais, Department of Nuclear Engineering, Av. Pres. Antonio Carlos 6627, Pampulha, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2017-10-15

    The dissemination of Computed Tomography (CT), a radiodiagnostic technique, has significant increase in the patient dose. In the last years, this technique has shown a high growth due to clinical cases of medical emergencies, neoplasm and pediatric traumas. Dose measurement is important to correlate with the deleterious effects of radiation on the organism and radiation future effects is related with stochastic risks due to tissue radiosensitivity, allied to the life expectancy of the child. In this work, a cylindrical phantom, representing an adult chest made of polymethylmethacrylate (PMMA), was used and a new born chest phantom with a shape oblong was developed based on the dimensions of a typical newborn. In a Ge CT scanner, Discovery model, with 64 channels, the central slice of the phantoms were irradiated successively in order to obtain dose measurements using an ionizing pencil camera. Based in the measurements, dose index was calculated (CTDI{sub vol}). The radiological service chest protocol using a voltage of 120 kV was used for scanning 10 cm of the central area of the adult and newborn phantom, in helical mode. An acquisition of images was performed using this radiological service chest protocol to compare with the protocol optimized. In the newborn phantom was also used protocols optimized using a voltage of 120 and 80 kV. The voltage of 80 kV has the lowest dose index for the pediatric object phantom. This work allowed the comparison between absorbed dose variations by the pediatric phantom changing the X-ray tube supply voltage. This dose variation has shown how important is specific protocols for children. (Author)

  9. Protocol optimization in chest CT scans of child

    International Nuclear Information System (INIS)

    Abrao L, L. T.; Amaral de O, F.; Prata M, A.; Bustos F, M.

    2017-10-01

    The dissemination of Computed Tomography (CT), a radiodiagnostic technique, has significant increase in the patient dose. In the last years, this technique has shown a high growth due to clinical cases of medical emergencies, neoplasm and pediatric traumas. Dose measurement is important to correlate with the deleterious effects of radiation on the organism and radiation future effects is related with stochastic risks due to tissue radiosensitivity, allied to the life expectancy of the child. In this work, a cylindrical phantom, representing an adult chest made of polymethylmethacrylate (PMMA), was used and a new born chest phantom with a shape oblong was developed based on the dimensions of a typical newborn. In a Ge CT scanner, Discovery model, with 64 channels, the central slice of the phantoms were irradiated successively in order to obtain dose measurements using an ionizing pencil camera. Based in the measurements, dose index was calculated (CTDI vol ). The radiological service chest protocol using a voltage of 120 kV was used for scanning 10 cm of the central area of the adult and newborn phantom, in helical mode. An acquisition of images was performed using this radiological service chest protocol to compare with the protocol optimized. In the newborn phantom was also used protocols optimized using a voltage of 120 and 80 kV. The voltage of 80 kV has the lowest dose index for the pediatric object phantom. This work allowed the comparison between absorbed dose variations by the pediatric phantom changing the X-ray tube supply voltage. This dose variation has shown how important is specific protocols for children. (Author)

  10. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  11. Extended Resection of Chest Wall Tumors with Reconstruction Using Poly Methyl Methacrylate-Mesh Prosthesis

    International Nuclear Information System (INIS)

    Abo Sedira, M.; Nassar, O.; Al-Ariny, A.

    2003-01-01

    This prospective study evaluates the early result of patients with massive chest wall tumors treated by extended resection and reconstruction using Prolene or Marlex mesh-enforced with Poly Methyl Methacrylate Bone Cement (PMMC) prosthesis. Material and Methods: This surgery was performed on 40 patients with a mean age of 45±18 (12-62) at the Department of Surgery, National Cancer Institute, Cairo University between 1998-2001. Primary chest wall tumors were the indications of surgery in 42.5%, while secondary involvement extending from other sites principally breast cancer were the indications for 57.5%. In 85% of patients more than 3 ribs were involved by tumors and lesions were more than 10 cm in the greatest dimension in 50% of cases. Resection involved sternum in 15 (37.5%) cases and in 45% of cases complete extensive rib resections extended between costovertebral junctions and the costochondral junctions were performed. Additional resections of nearby organs were needed in 20 (50%) of cases including partial lung resection in 14 cases, partial vertebral resection in 3 cases and diaphragm resection for 3 cases. Immediate bony reconstruction by inserting Prolene or Marlex mesh-enforced with Poly Methyl Methacrylate Bone Cement (PMMC) prosthesis to the resulting chest wall defect was performed in 36 cases, whereas, 4 cases had delayed reconstruction. Primary simple soft tissue closure was sufficient for 37.5% of patients; whereas 35% were covered by local rotational flap and 27.5% needed myocutaneous flaps. No patient with this immediate reconstruction needed ventilatory support or tracheostomy and flail chest was not noticed ICU stay was markedly reduced; whereas 85% required less than 7 days. Immediate post operative (40 days) complications were found in 14 patients (35%) and cases with additional lung resection had more complication rate than others (64% vs 19%). Infection occurred in 3 patients and conservative treatment for 3-4 weeks using frequent

  12. Intrathoracic tuberculous lymphadenopathy in children: a guide to chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    George, Anthony; Andronikou, Savvas [Bristol Royal Hospital for Children and the University of Bristol, Department of Paediatric Radiology, Bristol (United Kingdom); Pillay, Tanyia; Zar, Heather J. [University of Cape Town and Medical Research Council Unit on Child and Adolescent Health, Department of Paediatrics and Child Health, Red Cross War Memorial Children' s Hospital, Cape Town (South Africa); Goussard, Pierre [Tygerberg Hospital and the University of Stellenbosch, Department of Paediatrics and Child Health, Cape Town (South Africa)

    2017-09-15

    Making the diagnosis of pulmonary tuberculosis in children can be difficult because microbiological confirmation is not often achieved. Diagnosis is therefore often based on clinical features in combination with chest radiograph findings. Chest radiographs can demonstrate lymphadenopathy of the hilar and para-tracheal regions on the anteroposterior view, and subcarinal lymphadenopathy on the lateral view. However poor interobserver agreement has been reported for radiologist and clinician assessment of lymphadenopathy. This might reflect the lack of standardised imaging criteria for diagnosis as well as radiologists' objectives for achieving sensitivity rather than specificity. In this paper the authors provide a pictorial aid of chest radiographs in children with culture-confirmed tuberculosis to help clinicians identify lymph node enlargement in primary pulmonary tuberculosis. This collection of images comprises chest radiographs accompanied by schematics and either CT or MRI scan confirmation of pathological lymph node enlargement at the positions commonly affected in tuberculosis. (orig.)

  13. Chest ultrasonography for the emergency diagnosis of traumatic pneumothorax and haemothorax: A systematic review and meta-analysis.

    Science.gov (United States)

    Staub, Leonardo Jönck; Biscaro, Roberta Rodolfo Mazzali; Kaszubowski, Erikson; Maurici, Rosemeri

    2018-03-01

    To assess the accuracy of the chest ultrasonography for the emergency diagnosis of traumatic pneumothorax and haemothorax in adults. Systematic review and meta-analysis. PubMed, EMBASE, Scopus, Web of Science and LILACS (up to 2016) were systematically searched for prospective studies on the diagnostic accuracy of ultrasonography for pneumothorax and haemothorax in adult trauma patients. The references of other systematic reviews and the included studies were checked for further articles. The characteristics and results of the studies were extracted using a standardised form, and their methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Primary analysis was performed considering each hemithorax as an independent unit, while secondary analysis considered each patient. The global diagnostic accuracy of the chest ultrasonography was estimated using the Rutter-Gatsonis hierarchical summary ROC method. Moreover, Reitsma's bivariate model was used to estimate the sensitivity, specificity, positive likelihood ratio (LR + ) and negative likelihood ratio (LR-) of each sonographic sign. This review was previously registered (PROSPERO CRD42016048085). Nineteen studies were included in the review, 17 assessing pneumothorax and 5 assessing haemothorax. The reference standard was always chest tomography, alone or in parallel with chest radiography and observation of the chest tube. The overall methodological quality of the studies was low. The diagnostic accuracy of chest ultrasonography had an area under the curve (AUC) of 0.979 for pneumothorax (Fig). The absence of lung sliding and comet-tail artefacts was the most reported sonographic sign of pneumothorax, with a sensitivity of 0.81 (95% confidence interval [95%CI], 0.71-0.88), specificity of 0.98 (95%CI, 0.97-0.99), LR+ of 67.9 (95%CI, 26.3-148) and LR- of 0.18 (95%CI, 0.11-0.29). An echo-poor or anechoic area in the pleural space was the only sonographic sign for

  14. The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging

    International Nuclear Information System (INIS)

    Servaes, Sabah; Zhu, Xiaowei

    2013-01-01

    There are mechanisms within CT scanners and shielding that can be used to lower dose to patients. The objective of our study was to evaluate the dose changes and image quality with and without a breast shield for multidetector CT of the chest with angular tube current modulation. An anthropomorphic 5-year-old phantom was scanned with and without bismuth breast shielding and with and without angular tube current modulation. Image quality was assessed by measuring signal-to-noise ratio and contrast-to-noise ratio as well as measuring qualitatively. ANOVA single-factor p-value analysis of paired datasets was used for the statistical analysis. The breast shielding and angular tube current modulation resulted in a dose reduction to 85% for the breast and 90% overall. Although no qualitative differences were noted with and without the breast shielding used with angular tube current modulation, there were statistically significant differences in the contrast-to-noise ratio and CT numbers. When used with angular tube current modulation, breast shields influence the contrast-to-noise ratio and CT numbers, and therefore should not be used for chest CT. Greater dose reduction can be obtained by reducing the reference mAs (or reference noise index). (orig.)

  15. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  16. American College of Chest Physicians

    Science.gov (United States)

    ... Foundation Participate in the e-Community Get Social Career Connection Publications CHEST Journal CHEST SEEK Guidelines & Consensus Statements CHEST Physician CHEST NewsBrief Coding for Chest Medicine Tobacco Dependence Toolkit (3rd Ed.) Mobile Websites and Apps CHEST Journal ...

  17. Cracking and Corrosion of Composite Tubes in Black Liquor Recovery Boiler Primary Air Ports

    Energy Technology Data Exchange (ETDEWEB)

    Keiser, James R.; Singbeil, Douglas L.; Sarma, Gorti B.; Kish, Joseph R.; Yuan, Jerry; Frederick, Laurie A.; Choudhury, Kimberly A.; Gorog, J. Peter; Jetté, Francois R.; Hubbard, Camden R.; Swindeman, Robert W.; Singh, Prett M.; Maziasz, Phillip J.

    2006-10-01

    Black liquor recovery boilers are an essential part of kraft mills. Their design and operating procedures have changed over time with the goal of providing improved boiler performance. These performance improvements are frequently associated with an increase in heat flux and/or operating temperature with a subsequent increase in the demand on structural materials associated with operation at higher temperatures and/or in more corrosive environments. Improvements in structural materials have therefore been required. In most cases the alternate materials have provided acceptable solutions. However, in some cases the alternate materials have solved the original problem but introduced new issues. This report addresses the performance of materials in the tubes forming primary air port openings and, particularly, the problems associated with use of stainless steel clad carbon steel tubes and the solutions that have been identified.

  18. Cash's textbook of chest, heart and vascular disorders for physiotherapists

    Energy Technology Data Exchange (ETDEWEB)

    Downie, P.A.; Innocenti, D.M.; Jackson, S.E.

    1987-01-01

    This book includes a chapter on chest radiographs. A very high proportion of the patients treated by physiotherapy will have had a chest radiograph (x-ray) either because their primary disease is pulmonary or there is some long standing heart or lung illness which should be taken into account during the management of an acute problem. The chapter outlines the principles involved in reading the radiograph.

  19. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement.

    Science.gov (United States)

    Pfeiffer, P; Rudolph, S S; Børglum, J; Isbye, D L

    2011-11-01

    This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation. A prospective, paired, and investigator-blinded study carried out in the operating theatre. Twenty-five adult patients requiring endotracheal intubation were included. During intubation, transtracheal ultrasound was performed to visualize passage of the endotracheal tube. During bag ventilation, bilateral lung ultrasound was performed for the detection of lung sliding as a sign of ventilation simultaneous with capnography and auscultation of the epigastrium and chest. Primary outcome measure was time difference to confirmed endotracheal intubation between ultrasound and auscultation alone. Secondary outcome measure was time difference between ultrasound and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. In 68% of patients, endotracheal tube placement was visualized by real-time transtracheal ultrasound. Comparing ultrasound with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for ultrasound was 40 s [interquartile range (IQR) 35-48 s] vs. 48 s (IQR 45-53 s), P auscultation alone. Median time for auscultation alone was 42 s (IQR 37-47 s), P = 0.6, with a mean difference of -0.88 s in favour of ultrasound (95% CI -4.2-2.5 s). Verification of endotracheal tube placement with ultrasound is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  20. Chest MRI

    Science.gov (United States)

    ... resonance imaging - chest; NMR - chest; MRI of the thorax; Thoracic MRI Patient Instructions ... Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology. In: Broaddus VC, Mason RJ, Ernst JD, et ...

  1. Chest Pain: First Aid

    Science.gov (United States)

    First aid Chest pain: First aid Chest pain: First aid By Mayo Clinic Staff Causes of chest pain can vary from minor problems, such as indigestion ... 26, 2018 Original article: http://www.mayoclinic.org/first-aid/first-aid-chest-pain/basics/ART-20056705 . Mayo ...

  2. Image processing in digital chest radiography

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Lehtovirta, J.; Matsi, P.; Soimakallio, S.

    1992-01-01

    The usefulness of digital image processing of chest radiographs was evaluated in a clinical study. In 54 patients, chest radiographs in the posteroanterior projection were obtained by both 14 inch digital image intensifier equipment and the conventional screen-film technique. The digital radiographs (512x512 image format) viewed on a 625 line monitor were processed in 3 different ways: 1.standard display; 2.digital edge enhancement for the standard display; 3.inverse intensity display. The radiographs were interpreted independently by 3 radiologists. Diagnoses were confirmed by CT, follow-up radiographs and clinical records. Chest abnormalities of the films analyzed included 21 primary lung tumors, 44 pulmonary nodules, 16 cases with mediastinal disease, 17 with pneumonia /atelectasis. Interstitial lung disease, pleural plaques, and pulmonary emphysema were found in 30, 18 and 19 cases respectively. Sensitivity of conventional radiography when averaged overall findings was better than that of digital techniques (P<0.001). Differences in diagnostic accuracy measured by sensitivity and specificity between the 3 digital display modes were small. Standard image display showed better sensitivity for pulmonary nodules (0.74 vs 0.66; P<0.05) but poorer specificity for pulmonary emphysema (0.85 vs 0.93; P<0.05) compared with inverse intensity display. It is concluded that when using 512x512 image format, the routine use of digital edge enhancement and tone reversal at digital chest radiographs is not warranted. (author). 12 refs.; 4 figs.; 2 tabs

  3. Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Rendon, Xochitl; Develter, Wim [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Leuven (Belgium); Zhang, Guozhi; Coudyzer, Walter; Zanca, Federica [University Hospitals of the KU Leuven, Department of Radiology, Leuven (Belgium); Bosmans, Hilde [KU Leuven, Department of Imaging and Pathology, Division of Medical Physics and Quality Assessment, Leuven (Belgium); University Hospitals of the KU Leuven, Department of Radiology, Leuven (Belgium)

    2017-11-15

    To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI{sub vol} of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI{sub vol} of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI{sub vol} values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. (orig.)

  4. Fluoroscopic-guided primary single-step percutaneous gastrostomy. Initial results using the Freka {sup registered} GastroTube; Primaere einzeitige durchleuchtungsgesteuerte perkutane Gastrostomie (PG). Erste Ergebnisse mit dem Freka {sup registered} GastroTube

    Energy Technology Data Exchange (ETDEWEB)

    Hahne, J.D.; Schoennagel, B.P.; Arndt, C.; Bannas, P.; Koops, A.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Herrmann, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Universitaetsklinikum Hamburg-Eppendorf (Germany). Abt. Paediatrische Radiologie

    2011-07-15

    Purpose: To determine the practicability and outcome of fluoroscopic-guided primary one-step treatment of percutaneous gastrostomy (PG) with the system Freka {sup registered} Gastro Tube (Fresenius Kabi, Germany). Materials and Methods: In 39 patients (mean age 62.7 {+-} 12.0 years), primary PG was performed based on clinical indication from August 2009 to April 2010. The intervention was performed by an experienced radiologist under aseptic conditions by direct puncture with Freka {sup registered} Gastro Tube under fluoroscopic guidance. The clinical data and outcome as well as any complications originated from the electronic archive of the University Medical Center Hamburg-Eppendorf. Results: The intervention was technically successful in all 39 patients. Within the mean follow-up time of 155.3 {+-} 73.6 days, 29 patients (74.4 %) did not experience complications. 10 patients (25.6 %) had to be revised. Complications manifested after a mean of 135.6 {+-} 61.2 days and mainly corresponded to accidental dislocation (50 %). One patient had to be surgically revised under suspicion of a malpositioned tube and suspected intestinal perforation. Clinically relevant wound infections were not detected. The total costs per patient were 553.17 Euro for our single-step treatment (OPS 5 - 431.x) vs. 963.69 Euro (OPS 5 - 431.x and OPS 8 - 123.0) for the recommended two-step treatment. Conclusion: Fluoroscopic-guided primary single-step treatment with Freka {sup registered} Gastro Tube system is feasible and not associated with an increased complication rate when compared to published literature applying a two-step treatment approach. Material costs as well as human and time resources could be significantly reduced using the single-step treatment. (orig.)

  5. Pediatric chest imaging. Chest imaging in infants and children. 2. rev. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Lucaya, Javier [Vall d' Hebron Hospitals, Barcelona (Spain). Dept. of Pediatric Radiology and Inst. of Diagnostic Imaging; Hospital Quiron, Barcelona (Spain). Dept. of Radiology; Strife, Janet L. (eds.) [Cincinnati Univ. Coll. of Medicine, Cincinnati, OH (United States). Dept. of Radiology Cincinnati Children' s Hospital Medical Center

    2008-07-01

    Imaging of the pediatric chest continues to evolve rapidly. All chapters in this 2nd edition of Pediatric Chest Imaging have been extensively updated, with additional disease-specific information and numerous new illustrations. The book thus presents the state of the art in the diagnosis of pediatric chest disorders, highlighting the role played by advanced technology. As the conventional features of most of these disorders are extremely well known, special attention is devoted to the technical aspects of the modern imaging modalities, their indications, and the diagnostic information that they supply. Individual chapters focus on chest ultrasound, nuclear medicine imaging, high-resolution chest CT, helical CT, and pediatric cardiac CT and pediatric cardiacMRI. Others are directed towards specific disorders, including congenital malformations of the chest, chest tumors, pulmonary infection, trauma, the lung in systemic diseases, the pediatric airway, foreign bodies, the thymus, and the chest wall. Without exception, the authors of this book are internationally known specialists with great expertise in the field. This book will serve as a handy, superbly illustrated reference for all who routinely image children, as well as for those who need access to information on how best to image them. (orig.)

  6. Intravital Microscopy in Evaluating Patients With Primary Peritoneal, Fallopian Tube, or Stage IA-IV Ovarian Cancer

    Science.gov (United States)

    2018-06-04

    Fallopian Tube Carcinoma; Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Ovarian Cancer; Stage IB Ovarian Cancer; Stage IC Ovarian Cancer; Stage II Ovarian Cancer; Stage IIA Ovarian Cancer; Stage IIB Ovarian Cancer; Stage IIC Ovarian Cancer; Stage III Ovarian Cancer; Stage IIIA Ovarian Cancer; Stage IIIB Ovarian Cancer; Stage IIIC Ovarian Cancer; Stage IV Ovarian Cancer

  7. Gas tube-switched high voltage DC power converter

    Science.gov (United States)

    She, Xu; Bray, James William; Sommerer, Timothy John; Chokhawala, Rahul

    2018-05-15

    A direct current (DC)-DC converter includes a transformer and a gas tube-switched inverter circuit. The transformer includes a primary winding and a secondary winding. The gas tube-switched inverter circuit includes first and second inverter load terminals and first and second inverter input terminals. The first and second inverter load terminals are coupled to the primary winding. The first and second inverter input terminals are couplable to a DC node. The gas tube-switched inverter circuit further includes a plurality of gas tube switches respectively coupled between the first and second inverter load terminals and the first and second inverter input terminals. The plurality of gas tube switches is configured to operate to generate an alternating current (AC) voltage at the primary winding.

  8. Direct digital acquisition of neonatal portable chest radiographs

    International Nuclear Information System (INIS)

    Cohen, M.D.; Cory, D.A.; Broderick, N.J.; Smith, J.A.

    1987-01-01

    The Philips computerized radiography system utilizes a phosphor plate instead of an x-ray film to acquire radiographic images. The latent image on the plate is converted to a digital format. The authors report their initial experience with the system in more than 300 studies on intensive care neonates. The digital images provide very uniform image density. Tubes and catheters are more easily visualized than on conventional images. Soft tissues of the chest wall and bony structures are also more clearly seen on the digital images. The authors' initial experience indicates that portable digital imaging of neonates is technically feasible and provides good-quality diagnostic images

  9. Clinical Databases for Chest Physicians.

    Science.gov (United States)

    Courtwright, Andrew M; Gabriel, Peter E

    2018-04-01

    A clinical database is a repository of patient medical and sociodemographic information focused on one or more specific health condition or exposure. Although clinical databases may be used for research purposes, their primary goal is to collect and track patient data for quality improvement, quality assurance, and/or actual clinical management. This article aims to provide an introduction and practical advice on the development of small-scale clinical databases for chest physicians and practice groups. Through example projects, we discuss the pros and cons of available technical platforms, including Microsoft Excel and Access, relational database management systems such as Oracle and PostgreSQL, and Research Electronic Data Capture. We consider approaches to deciding the base unit of data collection, creating consensus around variable definitions, and structuring routine clinical care to complement database aims. We conclude with an overview of regulatory and security considerations for clinical databases. Copyright © 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  10. Development of a pediatric chest phantom for dosimetry in computerized tomography

    International Nuclear Information System (INIS)

    Aburjaile, W.N.; Mourão, A.P.; Oliveira, F.A.

    2017-01-01

    Computed Tomography (CT) has promoted a significant increase in the dose absorbed by patients due to the diagnosis. Therefore, it is indispensable to improve protocols, using smaller doses, without impairing the diagnostic quality of the image. The risks of stochastic effects are greater for children due to tissue radiosensitivity coupled with longer life expectancy. In the work, a cylindrical simulator was used, representing an adult thorax, made of polymethylmethacrylate, and a second simulator object of the same material was developed in oblong format including the axillary regions based on the dimensions of the pediatric patient's 8-year-old chest. A comparative study was performed between chest scans performed on two CT equipment in different radiodiagnostic services. The central slice of the two simulating objects was irradiated successively and, using a pencil-type ionization chamber, the absorbed dose was measured at five different points of each simulating object. From the measurements, weighted Dose and Volumetric Dose Index (CK, PMMA, vol) values were obtained for the 10 cm sweep of the central region of the object, in helical mode. The scans were performed using the chest acquisition protocols used by radiodiagnostic services, both for a supply voltage of the 120 kV X-ray tube. The study allowed to compare the variation of absorbed dose between patients with distinct chest volumes and the patient dose variation between two devices when used for the generation of images with the same diagnostic objective

  11. Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    Science.gov (United States)

    Lakhani, Paras

    2017-08-01

    The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal position of the ET tube (n = 300), and chest/abdominal radiographs (n = 120). The datasets were split into training, validation, and test. Both untrained and pre-trained deep neural networks were employed, including AlexNet and GoogLeNet classifiers, using the Caffe framework. Data augmentation was performed for the presence/absence and low/normal ET tube datasets. Receiver operating characteristic (ROC), area under the curves (AUC), and 95% confidence intervals were calculated. Statistical differences of the AUCs were determined using a non-parametric approach. The pre-trained AlexNet and GoogLeNet classifiers had perfect accuracy (AUC 1.00) in differentiating chest vs. abdominal radiographs, using only 45 training cases. For more difficult datasets, including the presence/absence and low/normal position endotracheal tubes, more training cases, pre-trained networks, and data-augmentation approaches were helpful to increase accuracy. The best-performing network for classifying presence vs. absence of an ET tube was still very accurate with an AUC of 0.99. However, for the most difficult dataset, such as low vs. normal position of the endotracheal tube, DCNNs did not perform as well, but achieved a reasonable AUC of 0.81.

  12. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38

  13. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  14. Esophageal rupture caused by explosion of an automobile tire tube: a case report.

    Science.gov (United States)

    Yu, Yongkang; Ding, Sheng; Zheng, Yifeng; Li, Wei; Yang, Lie; Zheng, Xiushan; Liu, Xiaoyan; Jiang, Jianqing

    2013-08-23

    There have been no reports in the literature of esophageal rupture in adults resulting from an explosion of an automobile tire. We report the first case of just such an occurrence after an individual bit into a tire, causing it to explode in his mouth. A 47-year-old Han Chinese man presented with massive hemorrhage in his left eye after he accidentally bit an automobile tire tube which burst into his mouth. He was diagnosed with esophageal rupture based on a chest computed tomography scan and barium swallow examination. Drainage of empyema (right chest), removal of thoracic esophagus, exposure of cervical esophagus, cardiac ligation and gastrostomy were performed respectively. After that, esophagogastrostomy was performed. Successful anastomosis was obtained at the neck with no postoperative complications 3 months after the surgery. The patient was discharged with satisfactory outcomes. We present this case report to bring attention to esophageal rupture in adults during the explosion of an automobile tire tube in the mouth.

  15. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient ({gamma}{sup 2} = 0.86, P < 0.001). For the next study, 177 patients (mean age, 7.9 years; the CTDIvol group) underwent contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the best fit equation. CTDIvol values on the dose report after CT scanning, noise differences from the target noise, areas, and mean densities were compared between these two groups. The CTDIvol values (mean{+-}standard deviation, 1.6 {+-} 0.7 mGy) and the noise differences from the target noise (1.1 {+-} 0.9 HU) of the CTDIvol group were significantly lower than those of the weight-based group (2.0 {+-} 1.0 mGy, 1.8 {+-} 1.4 HU) (P < 0.001). In contrast, no statistically significant difference was found in area (317.0 {+-} 136.8 cm{sup 2} vs. 326.3 {+-} 124.8 cm{sup 2}), mean density (-212.9 {+-} 53.1 HU vs. -221.1 {+-} 56.3 HU), and image noise (13.8 {+-} 2.3 vs. 13.6 {+-} 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  16. The significance of routine thoracic computed tomography in patients with blunt chest trauma.

    Science.gov (United States)

    Çorbacıoğlu, Seref Kerem; Er, Erhan; Aslan, Sahin; Seviner, Meltem; Aksel, Gökhan; Doğan, Nurettin Özgür; Güler, Sertaç; Bitir, Aysen

    2015-05-01

    The purpose of this study is to investigate whether the use of thoracic computed tomography (TCT) as part of nonselective computed tomography (CT) guidelines is superior to selective CT during the diagnosis of blunt chest trauma. This study was planned as a prospective cohort study, and it was conducted at the emergency department between 2013 and 2014. A total of 260 adult patients who did not meet the exclusion criteria were enrolled in the study. All patients were evaluated by an emergency physician, and their primary surveys were completed based on the Advanced Trauma Life Support (ATLS) principles. Based on the initial findings and ATLS recommendations, patients in whom thoracic CT was indicated were determined (selective CT group). Routine CTs were then performed on all patients. Thoracic injuries were found in 97 (37.3%) patients following routine TCT. In 53 (20%) patients, thoracic injuries were found by selective CT. Routine TCT was able to detect chest injury in 44 (16%) patients for whom selective TCT would not otherwise be ordered based on the EP evaluation (nonselective TCT group). Five (2%) patients in this nonselective TCT group required tube thoracostomy, while there was no additional treatment provided for thoracic injuries in the remaining 39 (15%). In conclusion, we found that the nonselective TCT method was superior to the selective TCT method in detecting thoracic injuries in patients with blunt trauma. Furthermore, we were able to demonstrate that the nonselective TCT method can change the course of patient management albeit at low rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Reconstruction with a patient-specific titanium implant after a wide anterior chest wall resection

    Science.gov (United States)

    Turna, Akif; Kavakli, Kuthan; Sapmaz, Ersin; Arslan, Hakan; Caylak, Hasan; Gokce, Hasan Suat; Demirkaya, Ahmet

    2014-01-01

    The reconstruction of full-thickness chest wall defects is a challenging problem for thoracic surgeons, particularly after a wide resection of the chest wall that includes the sternum. The location and the size of the defect play a major role when selecting the method of reconstruction, while acceptable cosmetic and functional results remain the primary goal. Improvements in preoperative imaging techniques and reconstruction materials have an important role when planning and performing a wide chest wall resection with a low morbidity rate. In this report, we describe the reconstruction of a wide anterior chest wall defect with a patient-specific custom-made titanium implant. An infected mammary tumour recurrence in a 62-year old female, located at the anterior chest wall including the sternum, was resected, followed by a large custom-made titanium implant. Latissimus dorsi flap and split-thickness graft were also used for covering the implant successfully. A titanium custom-made chest wall implant could be a viable alternative for patients who had large chest wall tumours. PMID:24227881

  18. Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

    International Nuclear Information System (INIS)

    Hwang, Hye Jeon; Seo, Joon Beom; Lee, Jin Seong; Song, Jae Woo; Lee, Hyun Joo; Lim, Chae Hun; Kim, Song Soo

    2012-01-01

    To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.

  19. Competence in confirming correct placement of nasogastric feeding tubes amongst FY1 doctors

    OpenAIRE

    Lee, Sindy; Mason, Eleanor

    2013-01-01

    Foundation year one (FY1) doctors are required to confirm correct placement of nasogastric (NG) feeding tubes on chest radiography on a regular basis. Many FY1s do not receive formal training during medical school or during the FY1 year. Multiple incidents of harm to patients, including death, resulting from incorrect placement of an NG feeding tube have been reported to the National Patient Safety Agency (NPSA) since 2005. Our audit assessed the confidence and knowledge of FY1 doctors in cor...

  20. Management of advanced-stage primary carcinoma of the fallopian tube: case report and literature review.

    Science.gov (United States)

    Kuscu, E; Oktem, M; Haberal, A; Erkanli, S; Bilezikci, B; Demirhan, B

    2003-01-01

    Primary carcinoma of the fallopian tube is a very unusual gynecologic malignancy that accounts for less than 1% of all malignancies of the female genitalia. A 55-year-old, gravida 7, para 3 woman presented with no gynecologic complaints other than backache. TVS demonstrated a 35 x 25 mm heterogeneous mass that was not clearly separated from the left ovary, and another 31 x 14 mm cystic septated lesion in the left ovary region. Pelvic MRI demonstrated a 35 x 35 x 20 mm left adnexal mass that enhanced with contrast and a neighboring tubular-cystic mass. Upper and lower gastrointestinal endoscopy revealed no malignancy. Serum CA 125-level was merkedly elevated at 369 U/ml (normal serous adenocarcinoma. Total abdominal hysterectomy, bilateral salpingo-oophorectomy, appendectomy, omentectomy, pelvic and para-aortic lymph node dissection, and peritoneal washing were performed. The definitive histopathological diagnosis was primary serous adenocarcinoma of the fallopian tube with six of 25 lymph node biopsies showing metastasis. Six cycles of paclitaxel (175 mg/m2) plus cisplatin (75 mg/m2) combinatin chemotherapy were administered with 3-week intervals between cycles. Second-look laparotomy was performed; there was no evidence of disease. At the time of writing 12 months after the second-look laparotomy, she was still disease-free.

  1. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  2. Evaluation of entrance surface air kerma in pediatric chest radiography

    Science.gov (United States)

    Porto, L.; Lunelli, N.; Paschuk, S.; Oliveira, A.; Ferreira, J. L.; Schelin, H.; Miguel, C.; Denyak, V.; Kmiecik, C.; Tilly, J.; Khoury, H.

    2014-11-01

    The objective of this study was to evaluate the entrance surface air kerma in pediatric chest radiography. An evaluation of 301 radiographical examinations in anterior-posterior (AP) and posterior-anterior (PA) (166 examinations) and lateral (LAT) (135 examinations) projections was performed. The analyses were performed on patients grouped by age; the groups included ages 0-1 y, 1-5 y, 5-10 y, and 10-15 y. The entrance surface air kerma was determined with DoseCal software (Radiological Protection Center of Saint George's Hospital, London) and thermoluminescent dosimeters. Two different exposure techniques were compared. The doses received by patients who had undergone LAT examinations were 40% higher, on average, those in AP/PA examinations because of the difference in tube voltage. A large high-dose “tail” was observed for children up to 5 y old. An increase in tube potential and corresponding decrease in current lead to a significant dose reduction. The difference between the average dose values for different age ranges was not practically observed, implying that the exposure techniques are still not optimal. Exposure doses received using the higher tube voltage and lower current-time product correspond to the international diagnostic reference levels.

  3. Preoperative computed tomography of the chest in lung cancer patients: the predictive value of calcified lymph nodes for the perioperative outcomes of video-assisted thoracoscopic surgery lobectomy

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam; Lee, Youkyung; Wi, Jae Yeon [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Moon, Hyeon-Jong; Sung, Yong Won [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Cardiothoracic Surgery, Seoul (Korea, Republic of)

    2013-12-15

    To determine the predictive value of identifying calcified lymph nodes (LNs) for the perioperative outcomes of video-assisted thoracoscopic surgery (VATS). Fifty-six consecutive patients who underwent VATS lobectomy for lung cancer were included. We evaluated the number and location of calcified LNs on computed tomography (CT). We investigated clinical parameters, including percentage forced expiratory volume in 1 s (FEV{sub 1}%), surgery duration, chest tube indwelling duration, and length of hospital stay. We performed linear regression analysis and multiple comparisons of perioperative outcomes. Mean number of calcified LNs per patient was 0.9 (range, 0-6), mostly located in the hilar-interlobar zone (43.8 %). For surgery duration (mean, 5.0 h), FEV{sub 1}% and emphysema severity were independent predictors (P = 0.010 and 0.003, respectively). The number of calcified LNs was an independent predictor for chest tube indwelling duration (P = 0.030) and length of hospital stay (P = 0.046). Mean duration of chest tube indwelling and hospital stay was 8.8 days and 12.7 days in no calcified LN group; 9.2 and 13.2 in 1 calcified LN group; 12.8 and 19.7 in {>=}2 calcified LNs group, respectively. The presence of calcified LNs on CT can help predict more complicated perioperative course following VATS lobectomy. (orig.)

  4. The Analysis of the Chest Tube Thoracostomies Performed in a Newly Established Hospital of a Medical School

    Directory of Open Access Journals (Sweden)

    Timucin Alar

    2014-03-01

    Full Text Available Aim: We have analyzed the chest tube thoracostomies (CTT performed in our Thoracic Surgery clinics of our newly established medical school hospital. Material and Method: The medical records of 130 patients to whom CTT were performed by the Thoracic Surgery Clinics of the Canakkale Onsekiz Mart University from December 2009 to July 2013 were retrospectively analyzed. Results: 102 patients (78% out of 130 were male and 28 (22% were women. Mean age of the patients were 58.9±20.4. 19% (n:25 of these patients were diagnosed at our clinics and the remaining 81% (n:105 were consultated from other clinics The most common indication of CTT was pleural effusion (35%, n:45. The mean fluid drainage of the patients with pleural effusions for various reasons (63%, n:84 were 1462.80±1054.46. The mean air drainage time for the patients with pneumothorax for various reasons (37%, n:46 were 5.8±3.1 days. There was only one complication (0,8% in these 130 patients which was the intraparanchymal drain placement. Discussion: As a procedure that is usually performed under emergency conditions CTT has a high potential for development of serious complications and thus increasing the importance of resident doctor training in Thoracic Surgery clinics. CTT has a low rate of complications when performed with the right indication, at the appropriate location and in devotion to the surgical principles; can increase the importance of the Thoracic Surgeons in the medical centers that they are working at and can also increase the relationship of the Thoracic Surgery clinics with the other clinics.

  5. Chest Seal Placement for Penetrating Chest Wounds by Prehospital Ground Forces in Afghanistan.

    Science.gov (United States)

    Schauer, Steven G; April, Michael D; Naylor, Jason F; Simon, Erica M; Fisher, Andrew D; Cunningham, Cord W; Morissette, Daniel M; Fernandez, Jessie Renee D; Ryan, Kathy L

    Thoracic trauma represents 5% of all battlefield injuries. Communicating pneumothoraces resulting in tension physiology remain an important etiology of prehospital mortality. In addressing penetrating chest trauma, current Tactical Combat Casualty Care (TCCC) guidelines advocate the immediate placement of a vented chest seal device. Although the Committee on TCCC (CoTCCC) has approved numerous chest seal devices for battlefield use, few data exist regarding their use in a combat zone setting. To evaluate adherence to TCCC guidelines for chest seal placement among personnel deployed to Afghanistan. We obtained data from the Prehospital Trauma Registry (PHTR). Joint Trauma System personnel linked patients to the Department of Defense Trauma Registry, when available, for outcome data upon reaching a fixed facility. In the PHTR, we identified 62 patients with documented gunshot wound (GSW) or puncture wound trauma to the chest. The majority (74.2%; n = 46) of these were due to GSW, with the remainder either explosive-based puncture wounds (22.6%; n = 14) or a combination of GSW and explosive (3.2%; n = 2). Of the 62 casualties with documented GSW or puncture wounds, 46 (74.2%) underwent chest seal placement. Higher proportions of patients with medical officers in their chain of care underwent chest seal placement than those that did not (63.0% versus 37.0%). The majority of chest seals placed were not vented. Of patients with a GSW or puncture wound to the chest, 74.2% underwent chest seal placement. Most of the chest seals placed were not vented in accordance with guidelines, despite the guideline update midway through the study period. These data suggest the need to improve predeployment training on TCCC guidelines and matching of the Army logistical supply chain to the devices recommended by the CoTCCC. 2017.

  6. MRI of the Chest

    Medline Plus

    Full Text Available ... gives detailed pictures of structures within the chest cavity, including the mediastinum , chest wall, pleura, heart and ... helpful to assess the vessels of the chest cavity (arteries and veins). MRA can also demonstrate an ...

  7. MRI of the Chest

    Medline Plus

    Full Text Available ... to produce detailed pictures of organs, soft tissues, bone and virtually all other internal body structures. MRI ... of the chest. assess disorders of the chest bones (vertebrae, ribs and sternum) and chest wall soft ...

  8. [Chest trauma].

    Science.gov (United States)

    Freixinet Gilart, Jorge; Ramírez Gil, María Elena; Gallardo Valera, Gregorio; Moreno Casado, Paula

    2011-01-01

    Chest trauma is a frequent problem arising from lesions caused by domestic and occupational activities and especially road traffic accidents. These injuries can be analyzed from distinct points of view, ranging from consideration of the most severe injuries, especially in the context of multiple trauma, to the specific characteristics of blunt and open trauma. In the present article, these injuries are discussed according to the involvement of the various thoracic structures. Rib fractures are the most frequent chest injuries and their diagnosis and treatment is straightforward, although these injuries can be severe if more than three ribs are affected and when there is major associated morbidity. Lung contusion is the most common visceral lesion. These injuries are usually found in severe chest trauma and are often associated with other thoracic and intrathoracic lesions. Treatment is based on general support measures. Pleural complications, such as hemothorax and pneumothorax, are also frequent. Their diagnosis is also straightforward and treatment is based on pleural drainage. This article also analyzes other complex situations, notably airway trauma, which is usually very severe in blunt chest trauma and less severe and even suitable for conservative treatment in iatrogenic injury due to tracheal intubation. Rupture of the diaphragm usually causes a diaphragmatic hernia. Treatment is always surgical. Myocardial contusions should be suspected in anterior chest trauma and in sternal fractures. Treatment is conservative. Other chest injuries, such as those of the great thoracic and esophageal vessels, are less frequent but are especially severe. Copyright © 2011 Sociedad Española de Neumología y Cirugía Torácica. Published by Elsevier Espana. All rights reserved.

  9. Diagnosis and Treatment of Chest Injury and Emergency Diseases of Chest Organs

    Directory of Open Access Journals (Sweden)

    A. M. Khadjibaev

    2016-01-01

    Full Text Available Goal of research: to evaluate efficiency of videothoracoscopy in diagnosis and treatment of patients with injuries and emergency diseases ща chest organs.Material and methods: Study wasbased on treatment results analysis of 2111 patients with injuries and chest organs emergency diseases, who were treated at Republican Research Centre of Emergency Medicine in 2001-2014. Chest trauma made up 1396 (66,1% victims. There were 477 (22,6% patients with spontaneous pneumothorax. At the stages of initial diagnosis, the radiologic evaluations, CT investigations and videothoracoscopies were performed. In chest trauma patients the videothoracoscopy underwent in 844 cases, in spontaneous pneu#mothorax this method was employed in 290 patients. Complicated forms of lung echinococcosis were observed in 238 (11,3% patients and complicated forms of lung echinococcosis were evident in 72 patients.Results. Videothoracoscopy and video-assisted interventions allowed to eliminate lungs and pleura pathology in 1206 (57,1% patients, whereas the traditional methods were effective only in 905 cases (42,9%.Conclusions. Investigation methods such as multiplanar radioscopy, radiography, chest CT and videothora-coscopy must be included into algorithm of diagnosis and surgical treatment of chest injuries and emergency diseases of chest organs. At chest trauma the videothoracoscopy allows to avoid broad thoracotomy from 9,4% to 4,7% of cases, to reduce the frequency of repeated interventions from 17,4% to 0,5% and diminish a number of early postsurgery complications from 25,4% to 10,9%. Videothoracoscopy of chest traumas allows to reduce frequency of repeated interventions from 19,8 to 1,7%.

  10. Mechanical versus manual chest compressions for cardiac arrest.

    Science.gov (United States)

    Brooks, Steven C; Hassan, Nizar; Bigham, Blair L; Morrison, Laurie J

    2014-02-27

    This is the first update of the Cochrane review on mechanical chest compression devices published in 2011 (Brooks 2011). Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR). To assess the effectiveness of mechanical chest compressions versus standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. We searched the Cochrane Central Register of Controlled Studies (CENTRAL; 2013, Issue 12), MEDLINE Ovid (1946 to 2013 January Week 1), EMBASE (1980 to 2013 January Week 2), Science Citation abstracts (1960 to 18 November 2009), Science Citation Index-Expanded (SCI-EXPANDED) (1970 to 11 January 2013) on Thomson Reuters Web of Science, biotechnology and bioengineering abstracts (1982 to 18 November 2009), conference proceedings Citation Index-Science (CPCI-S) (1990 to 11 January 2013) and clinicaltrials.gov (2 August 2013). We applied no language restrictions. Experts in the field of mechanical chest compression devices and manufacturers were contacted. We included randomised controlled trials (RCTs), cluster RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with atraumatic cardiac arrest. Two review authors abstracted data independently; disagreement between review authors was resolved by consensus and by a third review author if consensus could not be reached. The methodologies of selected studies were evaluated by a single author for risk of bias. The primary outcome was survival to hospital discharge with good neurological outcome. We planned to use RevMan 5 (Version 5.2. The Nordic Cochrane Centre) and the DerSimonian & Laird method (random-effects model) to provide a pooled estimate for risk ratio (RR) with 95% confidence intervals (95% CIs), if data allowed. Two new studies were included in this update. Six trials in total, including data from 1166

  11. An experience of corrective surgery of 37 cases of chest deformity

    International Nuclear Information System (INIS)

    Rahim, K.; Majeed, F.; Wyne, A.; Raza, A.; Imtiaz, T.

    2014-01-01

    The study was carried out to ascertain the cosmetic outcome of corrective surgery for pectus deformity and to determine the morbidity associated with it. Study Design: Quasi-experimental study. Place and Duration of Study: The study was conducted in CMH Rawalpindi and CMH Quetta from 2007 to 2012. Methodology: Total number of cases operated for chest deformity was 37. Modified Welch procedure with sub perichondrial resection was done with a strut of prolene mesh in a majority of excavatum repairs and k wires in few. Pectoroplasty was subsequently carried out in all patients. Midline incision was made in a majority of patients. Submammary incision was made in some female patients with a lower deformity due to better cosmetic outcome. Inclusion criterion was patients with chest deformity without any cardiac and spinal deformity. Results: Age range was between 4 years to 12 years with mean age of 8 +- 2.3 years. Twenty four (65%) deformities were of excavatum and 9 (24%) were of carinatum type. Four (11%) cases were of unilateral asymmetrical deformity. Mean operating time was 95 +- 11 minutes. Transfusion was required in only 1 (3%) of the cases. There was no perioperative mortality. Four (11%) patients had formation of seroma and 3 (8%) developed pneumothorax which was aspirated without placement of chest tube. Two (5%) had surgical site infection. Fifteen (41%) patients were satisfied and 21 (57%) reported excellent results. Conclusion: Chest deformity correction is safe and effective procedure with acceptable cosmetic results. It is easy to perform and improves self image of the suffering individual. (author)

  12. Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research

    International Nuclear Information System (INIS)

    Takeda, Takeshi; Furusawa, Takayuki

    2001-07-01

    Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those obtained for the artificially defected tube. In UT echo amplitude of the PPWC tubes inspected was lower than 20% of distance-amplitude calibration curve. Thus, it was confirmed that there was no defect in depth, which was more than the detecting standard of the probes, on the outer surface of the heat transfer tubes of the PPWC inspected. (author)

  13. Stress analysis of HTR-10 steam generator heat exchanging tubes

    International Nuclear Information System (INIS)

    Dong Jianling; Zhang Xiaohang; Yin Dejian; Fu Jiyang

    2001-01-01

    Steam Generator (SG) heat exchanging tubes of 10 MW High Temperature Gas Cooled Reactor (HTR-10) are protective screens between the primary loop of helium with radioactivity and the secondary loop of feeding water and steam without radioactivity. Water and steam will enter into the primary loop when rupture of the heat exchanging tubes occurs, which lead to increase of the primary loop pressure and discharge of radioactive materials. Therefore it is important to guarantee the integrity of the tubes. The tube structure is spiral tube with small bending radius, which make it impossible to test with volumetric in-service detection. For such kind of spiral tube, using LBB concept to guarantee the integrity of the tubes is an important option. The author conducts stress analysis and calculation of HTR-10 SG heat exchanging tubes using the FEM code of piping stress analysis, PIPESTRESS. The maximum stress and the dangerous positions are obtained

  14. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  15. Imaging of chest trauma: radiological patterns of injury and diagnostic algorithms

    International Nuclear Information System (INIS)

    Lomoschitz, Fritz M.; Eisenhuber, Edith; Linnau, Ken F.; Peloschek, Philipp; Schoder, Maria; Bankier, Alexander A.

    2003-01-01

    In patients after chest trauma, imaging plays a key role for both, the primary diagnostic work-up, and the secondary assessment of potential treatment. Despite its well-known limitations, the anteroposterior chest radiograph remains the starting point of the imaging work-up. Adjunctive imaging with computed tomography, that recently is increasingly often performed on multidetector computed tomography units, adds essential information not readily available on the conventional radiograph. This allows better definition of trauma-associated thoracic injuries not only in acute traumatic aortic injury, but also in pulmonary, tracheobronchial, cardiac, diaphragmal, and thoracic skeletal injuries. This article reviews common radiographic findings in patients after chest trauma, shows typical imaging features resulting from thoracic injury, presents imaging algorithms, and recalls to the reader less common but clinically relevant entities encountered in patients after thoracic trauma

  16. Influence of the S/N ratio on the corrosion release of Alloy 690 tubes in a primary coolant

    International Nuclear Information System (INIS)

    Shim, Hee-Sang; Choi, Myung Sik; Kim, Kyung Mo; Seo, Myung Ji; Hur, Do Haeng; Choi, Tack-Sang; Yoo, One

    2014-01-01

    Alloy 690TT is a promising steam generator (SG) tube material of a pressurized water reactor due to its excellent resistance to stress corrosion cracking (SCC) that has caused problems in Alloy 600 as an old SG tube material. The qualities of this material have been managed thoroughly from manufacturing step under various specification regulations as well as in in-service step. For examples, the surface roughness are prescribed as the values less than 1.6 μm for the tube outside and 0.5 μm for the inside, respectively. In addition, the surface state and defect must be qualified through the eddy current test (ECT) and the ultrasonic test (UT) according to the ASME Section III, NB2550. Then, the signal-to-noise (S/N) ratio, which is measured using ECT bobbin probe, is the important criteria to determine the material and it shall be 15 to 1 or higher at the standard frequency for any fixed 0.5 m length of any tube. The corrosion behaviours of the Alloy 690TT under high-temperature pressurized primary water have been studied widely in a point of the SCC but discussed narrowly in a point of the corrosion release. In particular, the effect of the S/N ratio on the corrosion release of this material surface has been rarely investigated. In this work, we evaluate the influence of the S/N ratio on the corrosion release of Alloy 690 SG tubes. The specimens with different S/N ratio were selected through ECT bobbin inspection and a corrosion release test was conducted using a simulated primary circulation loop. The material properties and oxidation behaviours were investigated by surface profiler, scanning electron microscopy, transmission electron microscopy, grazing incidence X-ray diffraction and etc. As a result, the corrosion rate was matched preferably with the MRPC characteristics showing macroscopic surface state rather than with the bobbin S/N ratio results. (author)

  17. Accuracy of chest radiography versus chest computed tomography in hemodynamically stable patients with blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Chardoli Mojtaba

    2013-12-01

    Full Text Available 【Abstract】 Objective: Thoracic injuries are respon- sible for 25% of deaths of blunt traumas. Chest X-ray (CXR is the first diagnostic method in patients with blunt trauma. The aim of this study was to detect the accuracy of CXR versus chest computed tomograpgy (CT in hemodynami- cally stable patients with blunt chest trauma. Methods: Study was conducted at the emergency department of Sina Hospital from March 2011 to March 2012. Hemodynamically stable patients with at least 16 years of age who had blunt chest trauma were included. All patients underwent the same diagnostic protocol which consisted of physical examination, CXR and CT scan respectively. Results: Two hundreds patients (84% male and 16% female were included with a mean age of (37.9±13.7 years. Chin J Traumatol 2013;16(6:351-354 Rib fracture was the most common finding of CXR (12.5% and CT scan (25.5%. The sensitivity of CXR for hemothorax, thoracolumbar vertebra fractures and rib fractures were 20%, 49% and 49%, respectively. Pneumothorax, foreign body, emphysema, pulmonary contusion, liver hematoma and ster- num fracture were not diagnosed with CXR alone. Conclusion: Applying CT scan as the first-line diag- nostic modality in hemodynamically stable patients with blunt chest trauma can detect pathologies which may change management and outcome. Key words: Radiography; Thoracic injuries; Tomography, X-ray computed

  18. Imaging of fetal chest masses

    Energy Technology Data Exchange (ETDEWEB)

    Barth, Richard A. [Lucile Packard Children' s Hospital, Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2012-01-15

    Prenatal imaging with high-resolution US and rapid acquisition MRI plays a key role in the accurate diagnosis of congenital chest masses. Imaging has enhanced our understanding of the natural history of fetal lung masses, allowing for accurate prediction of outcome, parental counseling, and planning of pregnancy and newborn management. This paper will focus on congenital bronchopulmonary malformations, which account for the vast majority of primary lung masses in the fetus. In addition, anomalies that mimic masses and less common causes of lung masses will be discussed. (orig.)

  19. Blunt chest trauma.

    Science.gov (United States)

    Stewart, Daphne J

    2014-01-01

    Blunt chest trauma is associated with a wide range of injuries, many of which are life threatening. This article is a case study demonstrating a variety of traumatic chest injuries, including pathophysiology, diagnosis, and treatment. Literature on the diagnosis and treatment was reviewed, including both theoretical and research literature, from a variety of disciplines. The role of the advance practice nurse in trauma is also discussed as it relates to assessment, diagnosis, and treatment of patients with traumatic chest injuries.

  20. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  1. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    Energy Technology Data Exchange (ETDEWEB)

    Teele, Sarah A.; Thiagarajan, Ravi R. [Children' s Hospital Boston, Department of Cardiology, Boston, MA (United States); Harvard Medical School, Department of Pediatrics, Boston, MA (United States); Emani, Sitaram M. [Children' s Hospital Boston, Department of Cardiac Surgery, Boston, MA (United States); Harvard Medical School, Department of Surgery, Boston, MA (United States); Teele, Rita L. [Harvard Medical School, Department of Radiology, Boston, MA (United States); Starship Children' s Hospital, Department of Radiology, Grafton (New Zealand)

    2008-10-15

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  2. Catheters, wires, tubes and drains on postoperative radiographs of pediatric cardiac patients: the whys and wherefores

    International Nuclear Information System (INIS)

    Teele, Sarah A.; Thiagarajan, Ravi R.; Emani, Sitaram M.; Teele, Rita L.

    2008-01-01

    Surgical treatment of congenital heart disease has advanced dramatically since the first intracardiac repairs in the mid-20th century. Previously inoperable lesions have become the focus of routine surgery and patients are managed successfully in intensive care units around the world. As a result, increasing numbers of postoperative images are processed by departments of radiology in children's hospitals. It is important that the radiologist accurately documents and describes the catheters, wires, tubes and drains that are present on the chest radiograph. This article reviews the reasons for the placement and positioning of perioperative equipment in children who have surgical repair of atrial septal defect, ventricular septal defect or transposition of the great arteries. Also included are a brief synopsis of each cardiac anomaly, the surgical procedure for its correction, and an in-depth discussion of the postoperative chest radiograph including illustrations of catheters, wires, tubes and drains. (orig.)

  3. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer—Health Professional Version

    Science.gov (United States)

    Ovarian epithelial, fallopian tube, and peritoneal cancers are diseases in which malignant cells form in the tissue covering the ovary, lining the fallopian tube, or peritoneum. Find evidence-based information on ovarian cancer treatment, causes and prevention, screening, research, genetics and statistics.

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  5. Pediatrics chest x-ray examination in general hospitals in Khartoum State

    International Nuclear Information System (INIS)

    Elawad, S. O. A.

    2011-01-01

    Study was performed to evaluate radiation dose for pediatric patients undergoing chest x-ray examination in selected general radiography hospitals in Khartoum State in seven x-ray machines. x-ray tube output measurements were made in the range of typical exposure parameters using calibrated dose rate meter. To estimate entrance surface air kerma (ESA K), the radiographer in charge of the facility was asked to provide typical exposure parameters (kV, m As and FSD) for each age category (newborn (1-30 days), 1,5.10 and years). ESA K was estimated using the x-ray tube output measurements and the recorded exposure parameters. The obtained mean ESA K range from /27/ to 57/ μGy, /25 -103/ μGy, /45-128/ μGy, /47-139/ μGy and from /68-299/ μGy for newborn, 1,5,10, and 15 years patients, respectively. The estimated ESA K were within the established international reference dose values and also the values obtained in previous studies. However, variations were observed in ESA K values among hospitals under study which could be due to the differences in exposure parameters used. Also tube output has some difference on the obtained ESA K. (Author)

  6. Stages of Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer

    Science.gov (United States)

    ... diagnosed, tests are done to find out if cancer cells have spread within the ovaries or to other parts of the body. The ... single ovary or fallopian tube. In stage IB, cancer is found inside both ovaries or fallopian tubes. In stage IC, cancer is ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... and chest wall and may be used to help evaluate shortness of breath, persistent cough, fever, chest ... or injury. It may also be useful to help diagnose and monitor treatment for a variety of ...

  8. Profile of chest trauma in Zaria Nigeria: A prelminary report

    Directory of Open Access Journals (Sweden)

    S A Edaigbini

    2011-01-01

    Materials and Methods A prospective study of trauma patients admitted to Ahmadu Bello University Teaching Hospital through the Accident and Emergency units was commenced in January 2008.This preliminary report is for the period of 27months.The clinical history, physical examination and outcome of management recorded in a predesigned proforma, were analysed with SPSS 15 and the patients were followed up in the surgical outpatient department. Results A total of 4784 patients (3143 men and 1641 women were admitted during this period for trauma. There were a total of 628(13.13% deaths. Of the 42 consecutive patients identified with chest trauma35 (83.3% were males and 7(16.7% were females. The age range was from 5-75years and the mean age was 35.4years, while the most affected ages were in the range of 20 to 49years. Blunt injury constituted 71.4% and penetrating injury constituted 28.6%. Road traffic accident was responsible for 61.9%, stab injury 21.4%, falls 7.1%, gunshot injury 4.8%, impalement 2.4% and animal attack also 2.4%. The average time taken between accident and admission was 31hours,40minutes and 12seconds while the average duration of hospital stay was 16.10 days. The injury pattern included rib fracture(s (23.8%, hemopneumothorax (14.3%, hemothorax (7.1%, pneumothorax (4.8%, combinations of chest injuries (7.1%, chest laceration 7.1%, bruises 11.9%, lung contusion 4.8%, subcutaneous empyema 2.4%, flail chest 4.8% and no specific injury (11.9%. Associated injuries included head injury (63.6%, orthopaedic injury (27.3% and combinations (abdominal, head, orthopaedic (9.1%. The fatality of road traffic accident was 36.8%. No patient was attended to by paramedics at the scene of accident while 21.9% of the patients had pre-hospital resuscitation in peripheral clinics before admission. The transfusion requirement was 14.3%. One patient (2.4% required a median sternotomy and cardiopulmonary bypass, 54.8% required tube thoracostomy while 42.9% had general

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  10. Gonad protective effect of radiation protective apron in chest radiography

    International Nuclear Information System (INIS)

    Hashimoto, Masatoshi; Kato, Hideyuki; Fujibuchi, Toshiou; Ochi, Shigehiro; Morita, Fuminori

    2004-01-01

    Depending on the facility, a radiation protective apron (protector) is used to protect the gonad from radiation exposure in chest radiography. To determine the necessity of using a protector during chest radiography, we measured the effect of the protector on the gonad in this study. First, using a human body phantom, we measured the absorbed dose of the female gonad with and without the protector, using a thermoluminescence dosimeter (TLD), and confirmed its protective effect. Using the protector, the absorbed dose was reduced to 28±2% and 39±4% for field sizes of 14 x 17 inch and 14 x 14 inch, respectively. Next, we used Monte Carlo simulation and confirmed, not only the validity of the actual measurement values, but also the fact that the influence of radiation on the absorbed dose of the gonad was mostly from scattered radiation from inside the body for the 14 x 17 inch field size, and also from the X-ray tube for the 14 x 14 inch field size. Although a certain protective effect is achieved by using the protector, the radiation dose to the gonad is only a few μGy even without a protector. Thus, the risk of a genetic effect would be as small as 10 -8 . Given that acceptable risk is below 10 -6 , we conclude the use of a radiation protective apron is not necessary for diagnostic chest radiography. (author)

  11. [Gonad protective effect of radiation protective apron in chest radiography].

    Science.gov (United States)

    Hashimoto, Masatoshi; Kato, Hideyuki; Fujibuchi, Toshiou; Ochi, Shigehiro; Morita, Fuminori

    2004-12-01

    Depending on the facility, a radiation protective apron (protector) is used to protect the gonad from radiation exposure in chest radiography. To determine the necessity of using a protector during chest radiography, we measured the effect of the protector on the gonad in this study. First, using a human body phantom, we measured the absorbed dose of the female gonad with and without the protector, using a thermoluminescence dosimeter (TLD), and confirmed its protective effect. Using the protector, the absorbed dose was reduced to 28+/-2% and 39+/-4% for field sizes of 14 x 17 inch and 14 x 14 inch, respectively. Next, we used Monte Carlo simulation and confirmed, not only the validity of the actual measurement values, but also the fact that the influence of radiation on the absorbed dose of the gonad was mostly from scattered radiation from inside the body for the 14 x 17 inch field size, and also from the X-ray tube for the 14 x 14 inch field size. Although a certain protective effect is achieved by using the protector, the radiation dose to the gonad is only a few microGy even without a protector. Thus, the risk of a genetic effect would be as small as 10(-8). Given that acceptable risk is below 10(-6), we conclude the use of a radiation protective apron is not necessary for diagnostic chest radiography.

  12. Digital chest tomosynthesis: the 2017 updated review of an emerging application

    Science.gov (United States)

    Ferrari, Arianna; Bertolaccini, Luca; Solli, Piergiorgio; Di Salvia, Paola Oriana

    2018-01-01

    Lung cancer is the leading cause of cancer death and second most common cancer among both men and women, but most of them are detected when patients become symptomatic and in late-stage. Chest radiography (CR) is a basic technique for the investigation of lung cancer and has the benefit of convenience and low radiation dose, but detection of malignancy is often difficult. The introduction of computed tomography (CT) for screening has increased the proportion of lung cancer detected but with higher exposure dose and higher costs. Digital chest tomosynthesis (DCT), a tomographic technique, may offer an alternative to CT. DCT uses a conventional radiograph tube, a flat-panel detector, a computer-controlled tube mover and reconstruction algorithms to produce section images. It shows promise in the detection of potentially malignant lung nodules, with higher sensibility than CR, and is emerging as a low-dose and low-cost alternative to CT to improve treatment decisions. In fact, an increasing number of researchers are showing that tomosynthesis could have a role in the detection of lung cancer, in addition to its present role in breast screening. However, DCT offers some limitations, such as limited depth resolution, which may explain the difficulty in detecting pathologies in the subpleural region and the occurrence of artefacts from medical devices. Once solved these limitations and once more studies supporting its use will be available, DCT could become the first-line lung cancer screening tool among patients at considerable risk of lung cancer. PMID:29666814

  13. Practical acoustic thermometry with twin-tube and single-tube sensors

    Energy Technology Data Exchange (ETDEWEB)

    De Podesta, M.; Sutton, G.; Edwards, G.; Stanger, L.; Preece, H. [National Physical Laboratory, Teddington, (United Kingdom)

    2015-07-01

    Accurate measurement of high temperatures in a nuclear environment presents unique challenges. All secondary techniques inevitably drift because the thermometric materials in thermocouples and resistance sensors are sensitive not just to temperature, but also their own chemical and physical composition. The solution is to use primary methods that rely on fundamental links between measurable physical properties and temperature. In the nuclear field the best known technique is the measurement of Johnson Noise in a resistor (See Paper 80 at this conference). In this paper we describe the measurement of temperature in terms of the speed of sound in a gas confined in a tube - an acoustic waveguide. Acoustic thermometry is the most accurate technique of primary thermometry ever devised with the best uncertainty of measurement below 0.001 C. In contrast, the acoustic technique described in this work has a much larger uncertainty, approximately 1 deg. C. But the cost and ease of use are improved by several orders of magnitude, making implementation eminently practical. We first describe the basic construction and method of operation of thermometers using twin-tubes and single tubes. We then present results using a twin-tube design showing that showing long term stability (i.e. no detectable drift) at 700 deg. C over periods of several weeks. We then outline how the technique may be developed for different nuclear applications. (authors)

  14. Noninvasive diagnostic methods in primary lung cancer Part one: sputum cytology and chest radiography; Metodos diagnosticos no invasivos en cancer pulmonar primario

    Energy Technology Data Exchange (ETDEWEB)

    Bastidas, Alirio; Garcia Herreros, Plutarco; Saavedra, Alfredo; Sanchez, Edgar

    2008-07-01

    Primary lung cancer is a world wide public health problem which generates immense costs to the health system and where its cure is only achieve by an early diagnosis associated to an opportune surgical treatment. For this purpose several non invasive diagnostic methods are currently available, among them the sputum cytology, chest radiography, computed tomography scanner and the positron emission tomography. In the present article, constituted by two parts, the usefulness of these diagnostic methods as screening, diagnosis, staging and follow up tools will be discuss on the basis of the current available literature for this type of neoplasm.

  15. Characterization and validation of the thorax phantom Lungman for dose assessment in chest radiography optimization studies.

    Science.gov (United States)

    Rodríguez Pérez, Sunay; Marshall, Nicholas William; Struelens, Lara; Bosmans, Hilde

    2018-01-01

    This work concerns the validation of the Kyoto-Kagaku thorax anthropomorphic phantom Lungman for use in chest radiography optimization. The equivalence in terms of polymethyl methacrylate (PMMA) was established for the lung and mediastinum regions of the phantom. Patient chest examination data acquired under automatic exposure control were collated over a 2-year period for a standard x-ray room. Parameters surveyed included exposure index, air kerma area product, and exposure time, which were compared with Lungman values. Finally, a voxel model was developed by segmenting computed tomography images of the phantom and implemented in PENELOPE/penEasy Monte Carlo code to compare phantom tissue-equivalent materials with materials from ICRP Publication 89 in terms of organ dose. PMMA equivalence varied depending on tube voltage, from 9.5 to 10.0 cm and from 13.5 to 13.7 cm, for the lungs and mediastinum regions, respectively. For the survey, close agreement was found between the phantom and the patients' median values (deviations lay between 8% and 14%). Differences in lung doses, an important organ for optimization in chest radiography, were below 13% when comparing the use of phantom tissue-equivalent materials versus ICRP materials. The study confirms the value of the Lungman for chest optimization studies.

  16. Painful Vaso-occlusive Crisis as a  Prodromal Phase of Acute Chest Syndrome. Is Only One Chest X-ray Enough? A Case Report

    Directory of Open Access Journals (Sweden)

    Charalambos Neocleous

    2013-01-01

    Full Text Available The predominant pathophysiological feature of homozygous sickle cell anemia (SCA is the vaso-occlusion. Vaso-occlusion can be associated with painful crises, which are the primary reason for those patients to seek medical care. Vaso-occlusion is responsible for the acute chest syndrome (ACS with large morbidity and mortality or more rarely (and especially in adults for priapism and acute neurological events (strokes. A 10-year-old boy with homozygous SCA was admitted to the Pediatric Emergencies with painful vaso-occlusive crisis and fever. Initially he had normal chest X-ray but, after 24-hour-hospitalization, he developed  ACS with new chest X-ray findings. He was treated with broad spectrum antibiotics, blood transfusions and bronchodilators and after a  six-day treatment, he was significantly improved. The patient was discharged 13 days later with no other therapy at home. The possibility of  ACS development should be still considered, even when a  known patient with SCA presents a  painful vaso-occlusive crisis with an initial normal chest X-ray. Therefore, repeated clinical examination is required and possible changes in  the clinical status could indicate the necessity of a  new radiographic examination. In  this way, early  ACS could be recognized and the catastrophic consequences due to this syndrome could be avoided.

  17. The place of clinical features and standard chest radiography in ...

    African Journals Online (AJOL)

    One hundred and five primary mediastinal masses were seen between 1975 and 1998, at the Cardiothoracic surgical Unit of the University College Hospital Ibadan. These were studied to establish the importance of clinical features and plain chest radiography in preoperative evaluation of these masses. The sources of ...

  18. Hepatic hydrothorax after blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Shang-Chiung Wang

    2012-08-01

    Full Text Available We report a successful treatment result in a rare case of hepatitis C virus-related cirrhosis, who had sustained hydrothorax after blunt thoracoabdominal trauma. This was a female patient with liver cirrhosis, Child–Turcotte–Pugh class A, without ascites before injury. She sustained blunt thoracoabdominal trauma with a left clavicle fracture dislocation and right rib fractures. There was no hemopneumothorax at initial presentation. However, dyspnea and right pleural effusion developed gradually. We inserted a chest tube to relieve the patient's symptoms, and the daily drainage amount remained consistent. Hepatic hydrothorax was confirmed by the intraperitoneal injection of radioisotope 99mTc-sulfur colloid that demonstrated one-way transdiaphragmatic flow of fluid from the peritoneal cavity to pleural cavities. Finally, the hydrothorax was treated successfully by minocycline-induced pleural symphysis. To the best of our knowledge, this is the first case of hepatic hydrothorax developed after thoracoabdominal trauma.

  19. Chest wall resection for multifocal osseous haemangioma.

    Science.gov (United States)

    Weinandt, Marthe; Legras, Antoine; Mordant, Pierre; Le Pimpec Barthes, Françoise

    2016-02-01

    Intraosseous haemangioma is a rare and benign primary tumour of the bone. We report the case of a 76-year old woman who presented the exceptional condition of multifocal cavernous haemangiomas involving the spine and the ribs, requiring spinal and chest wall resections to confirm the diagnosis and treat the symptoms. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Chest tomosynthesis: technical and clinical perspectives.

    Science.gov (United States)

    Johnsson, Ase Allansdotter; Vikgren, Jenny; Bath, Magnus

    2014-02-01

    The recent implementation of chest tomosynthesis is built on the availability of large, dose-efficient, high-resolution flat panel detectors, which enable the acquisition of the necessary number of projection radiographs to allow reconstruction of section images of the chest within one breath hold. A chest tomosynthesis examination obtains the increased diagnostic information provided by volumetric imaging at a radiation dose comparable to that of conventional chest radiography. There is evidence that the sensitivity of chest tomosynthesis may be at least three times higher than for conventional chest radiography for detection of pulmonary nodules. The sensitivity increases with increasing nodule size and attenuation and decreases for nodules with subpleural location. Differentiation between pleural and subpleural lesions is a known pitfall due to the limited depth resolution in chest tomosynthesis. Studies on different types of pathology report increased detectability in favor of chest tomosynthesis in comparison to chest radiography. The technique provides improved diagnostic accuracy and confidence in the diagnosis of suspected pulmonary lesions on chest radiography and facilitates the exclusion of pulmonary lesions in a majority of patients, avoiding the need for computed tomography (CT). However, motion artifacts can be a cumbersome limitation and breathing during the tomosynthesis image acquisition may result in severe artifacts significantly affecting the detectability of pathology. In summary, chest tomosynthesis has been shown to be superior to chest conventional radiography for many tasks and to be able to replace CT in selected cases. In our experience chest tomosynthesis is an efficient problem solver in daily clinical work. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Optimization of digital chest radiography using computer modeling and voxels phantoms

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.

    2009-01-01

    The purpose of this work is to use the Monte Carlo code MCNPX and the Female Adult voxel (FAX) and Male Adult voxel (MAX) phantoms to investigate how the dose and image quality in digital chest radiography vary with tube voltage (70-150 kV), anti-scatter methods (grid and air gap) and gender of the patient. The effective dose was calculated by ICRP60 and image quality was quantified by calculating the signal-difference-to-noise ratio for pathological details (calcifications) positioned at different locations in the anatomy. Calculated quantities were normalized to a fixed value of air kerma (5 μGy) at the automatic exposure control chambers. The results obtained in this work show that the air gap technique and lower tube voltages provide an increase in the digital image quality. Furthermore, this study has also shown that the detection of pathological details vary with the gender of the patient. (author)

  2. Design and Development of a New Multi-Projection X-Ray System for Chest Imaging

    Science.gov (United States)

    Chawla, Amarpreet S.; Boyce, Sarah; Washington, Lacey; McAdams, H. Page; Samei, Ehsan

    2009-02-01

    Overlapping anatomical structures may confound the detection of abnormal pathology, including lung nodules, in conventional single-projection chest radiography. To minimize this fundamental limiting factor, a dedicated digital multi-projection system for chest imaging was recently developed at the Radiology Department of Duke University. We are reporting the design of the multi-projection imaging system and its initial performance in an ongoing clinical trial. The system is capable of acquiring multiple full-field projections of the same patient along both the horizontal and vertical axes at variable speeds and acquisition frame rates. These images acquired in rapid succession from slightly different angles about the posterior-anterior (PA) orientation can be correlated to minimize the influence of overlying anatomy. The developed system has been tested for repeatability and motion blur artifacts to investigate its robustness for clinical trials. Excellent geometrical consistency was found in the tube motion, with positional errors for clinical settings within 1%. The effect of tube-motion on the image quality measured in terms of impact on the modulation transfer function (MTF) was found to be minimal. The system was deemed clinic-ready and a clinical trial was subsequently launched. The flexibility of image acquisition built into the system provides a unique opportunity to easily modify it for different clinical applications, including tomosynthesis, correlation imaging (CI), and stereoscopic imaging.

  3. CT of chest trauma

    International Nuclear Information System (INIS)

    Goodman, P.C.

    1986-01-01

    There appears to be a limited role for computed tomography in the evaluation of chest trauma. The literature contains few papers specifically addressing the use of CT in the setting of chest trauma. Another series of articles relates anecdotal experiences in this regard. This paucity of reports attests to the remarkable amount of information present on conventional chest radiographs as well as the lack of clear indications for CT in the setting of chest trauma. In this chapter traumatic lesions of various areas of the thorax are discussed. The conventional radiographic findings are briefly described and the potential or proven application of CT is addressed

  4. Usefulness of routine computed tomography in the evaluation of penetrating war injuries to the chest.

    Science.gov (United States)

    Darwish, Bassam; Mahfouz, Mohammad Z; Izzat, Mohammad Bashar

    2018-05-02

    This review was conducted to compare the contributions of chest X-ray (CXR) and computed tomography (CT) towards detecting intrathoracic damage in patients with penetrating war injuries to the chest and to determine whether identification of additional injuries by chest CT will have an impact on the choice of therapeutic interventions and clinical outcomes. We reviewed records of 449 patients (374 men, mean age 29.3 ± 14.8 years) who were admitted to our hospital with penetrating war injuries to the chest over a 7-year period. Collected data included mechanisms of injury, associated injuries, results of CXRs and chest CTs, methods of management, in-hospital stays, complications and mortalities. Immediate screening CXRs were obtained in all patients not requiring emergent thoracotomies, of which 91.4% showed positive signs of injury. Chest CTs were performed at the discretion of the physicians in 49.4% of patients, and CXR-positive findings were confirmed in all cases, while revealing additional injuries in 11% of patients. Chest CT findings led to additional closed chest drainage in 5.6% of patients but had no impact on treatment strategy in 94.4% of scanned patients. Follow-up CXRs showed new positive findings in 22 patients, leading to additional closed chest drainage in 3 patients and delayed open thoracotomies in 7 other patients. CXRs continue as the primary diagnostic modality in the assessment of patients with penetrating war injuries to the chest. Chest CTs can be omitted in most patients, thus reducing CT imaging case-load substantially, while most clinically significant chest injuries remain sufficiently recognized.

  5. Safety significance of steam generator tube degradation mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Roussel, G; Mignot, P [AIB-Vincotte Nuclear - AVN, Brussels (Belgium)

    1991-07-01

    Steam generator (SG) tube bundle is a part of the Reactor Coolant Pressure Boundary (RCPB): this means that its integrity must be maintained. However, operating experience shows various types of tube degradation to occur in the SG tubing, which may lead to SG tube leaks or SG tube ruptures and create a loss of primary system coolant through the SG, therefore providing a direct path to the environment outside the primary containment structure. In this paper, the major types of known SG tube degradations are described and analyzed in order to assess their safety significance with regard to SG tube integrity. In conclusion: The operational reliability and the safety of the PWR steam generator s requires a sufficient knowledge of the degradation mechanisms to determine the amount of degradation that a tube can withstand and the time that it may remain in operation. They also require the availability of inspection techniques to accurately detect and characterize the various degradations. The status of understanding of the major types of degradation summarized in this paper shows and justifies why efforts are being performed to improve the management of the steam generator tube defects.

  6. Learning chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pedrozo Pupo, John C. (ed.) [Magdalena Univ., Santa Maria (Colombia). Respire - Inst. for Respiratory Care

    2013-03-01

    Useful learning tool for practitioners and students. Overview of the imaging techniques used in chest radiology. Aid to the correct interpretation of chest X-ray images. Radiology of the thorax forms an indispensable element of the basic diagnostic process for many conditions and is of key importance in a variety of medical disciplines. This user-friendly book provides an overview of the imaging techniques used in chest radiology and presents numerous instructive case-based images with accompanying explanatory text. A wide range of clinical conditions and circumstances are covered with the aim of enabling the reader to confidently interpret chest images by correctly identifying structures of interest and the causes of abnormalities. This book, which will be an invaluable learning tool, forms part of the Learning Imaging series for medical students, residents, less experienced radiologists, and other medical staff. Learning Imaging is a unique case-based series for those in professional education in general and for physicians in prarticular.

  7. Chest radiology

    International Nuclear Information System (INIS)

    Reed, J.C.

    1990-01-01

    This book is a reference in plain chest film diagnosis provides a thorough background in the differential diagnosis of 22 of the most common radiologic patterns of chest disease. Each chapter is introduced with problem cases and a set of questions, followed by a tabular listing of the appropriate differential considerations. The book emphasizes plain films, CT and some MR scans are integrated to demonstrate how these modalities enhance the work of a case

  8. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients

    Directory of Open Access Journals (Sweden)

    Omar Hesham R

    2011-09-01

    Full Text Available Abstract Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.

  9. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients.

    Science.gov (United States)

    Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M

    2011-09-27

    Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.

  10. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  11. Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

    International Nuclear Information System (INIS)

    Ammar, Thoraya; Rio, Alan; Ampong, Mary Ann; Sidhu, Paul S.

    2010-01-01

    Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.

  12. Radiographic findings of primary lung cancer with delayed detection on chest radiographs

    International Nuclear Information System (INIS)

    Kim, Young Min; Kim, Jin Hwan; Jung, Bin Young; Jun, Kwang Jin; Jeong, Ki Ho; Kim, Ju Ok; Kim, Sun Young; Yang, Chang Kyu

    1999-01-01

    To analyze the causes of delayed detection of lung cancer on chest radiographs. We retrospectively reviewed 105 cases in which an initial diagnosis of lung cancer, based on an examination of plain radiographs, had been missed or misinterpreted. All occurred between October 1993 and April 1997. We reviewed the initial chest radiographs and compared the features noted with those seen on later chest radiographs and computed tomographic (CT) images. Undetected lung cancer was identified in 56 patients (56/105, 53.3%) It had been hidden by superimposed structures (41, 73.2%), overlapped by combined benign diseases (12, 21.4%), or the nodules were subtle (3, 5.4%). Of the 41 lung cancers hidden by a superimposed structure, the central type accounted for 29 (70.7%) and the peripheral type for 12 (29.3%). The 29 central type had been hidden by the left hilum (n=15), the right hilum (n=10), the heart (n=3), or a rib (n=1). The twelve peripheral type were hidden by a rib (n=7), the heart (n=2), the diaphragm (n=2), or the left hilum (n=1). Of the 12 lung cancers overlapped by combined benign diseases, pulmonary tuberculosis (n=6), pleural effusion (n=4), congestive heart failure (n=1), and diffuse interstitial lung disease (n=1) were present at the time of interpretation. The misinterpreted lung cancers were identified in 49 patients (49/105, 46.7%) and were seen to be combined with benign disease (16, 32.6%), or as obstructive pneumonia without a central mass (15, 30.6%), air-space consolidation (7, 14.3%), cavity (7, 14.3%), double lesion (2, 4.1%), or young age below 26 years (2,4.1%). Of the 16 lung cancers misinterpreted as combined disease, pulmonary tuberculosis (n=14) and pleural disease (n=2) had been initially diagnosed. Most commonly, lung cancer was missed or misinterpreted because it was hidden by a normal structure or combined with a benign disease. Perceptual errors can be reduced by appropriate techniques and the scrutiny of trouble spots such as the

  13. Does the quality of chest compressions deteriorate when the chest compression rate is above 120/min?

    Science.gov (United States)

    Lee, Soo Hoon; Kim, Kyuseok; Lee, Jae Hyuk; Kim, Taeyun; Kang, Changwoo; Park, Chanjong; Kim, Joonghee; Jo, You Hwan; Rhee, Joong Eui; Kim, Dong Hoon

    2014-08-01

    The quality of chest compressions along with defibrillation is the cornerstone of cardiopulmonary resuscitation (CPR), which is known to improve the outcome of cardiac arrest. We aimed to investigate the relationship between the compression rate and other CPR quality parameters including compression depth and recoil. A conventional CPR training for lay rescuers was performed 2 weeks before the 'CPR contest'. CPR anytime training kits were distributed to respective participants for self-training on their own in their own time. The participants were tested for two-person CPR in pairs. The quantitative and qualitative data regarding the quality of CPR were collected from a standardised check list and SkillReporter, and compared by the compression rate. A total of 161 teams consisting of 322 students, which includes 116 men and 206 women, participated in the CPR contest. The mean depth and rate for chest compression were 49.0±8.2 mm and 110.2±10.2/min. Significantly deeper chest compression depths were noted at rates over 120/min than those at any other rates (47.0±7.4, 48.8±8.4, 52.3±6.7, p=0.008). Chest compression depth was proportional to chest compression rate (r=0.206, pcompression including chest compression depth and chest recoil by chest compression rate. Further evaluation regarding the upper limit of the chest compression rate is needed to ensure complete full chest wall recoil while maintaining an adequate chest compression depth. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Intraoperative Atelectasis Due to Endotracheal Tube Cuff Herniation: A Case Report

    Directory of Open Access Journals (Sweden)

    Hossein Madineh

    2012-09-01

    Full Text Available Endotracheal tube (ETT cuff herniation is a rare, and often difficult to diagnose, cause of bronchial obstruction. We present a case of outside cuff herniation of an endotracheal tube that caused pulmonary right lung atelectasis. A 29-year-old man ,a case of car accident with multiple fractures, was admitted to the emergency ward and transferred to the operating room(OR for open reduction and internal fixation (ORIF of all fractures .The procedures were done under general anesthesia (G/A. The past medical history of the patient did not indicate any problem. Anesthesia was induced with thiopental, atracurium and then maintained by propofol and remifentanyl infusions and 100% O2 via orally inserted ETT. The patient was positioned in left lateral decubitus position for operation. Two hours after induction of anesthesia, the oxygen saturation level dropped to 85 % and the breath sounds in the right side of the chest were weakened. The chest x-ray images showed right lung atelectasis especially in the upper lobe. The problem was disappeared after removal of the ETT. In this case, we observed that an ETT cuff herniation can be a cause of airway obstruction. If there is a decreased unilateral breath sounds, we recommend replacement or repositioning of ETT.

  15. Annular gap measurement between pressure tube and calandria tube by eddy current technique

    International Nuclear Information System (INIS)

    Bhole, V.M.; Rastogi, P.K.; Kulkarni, P.G.

    1992-01-01

    In pressurised heavy water reactor (PHWR) major distinguishing feature is that there are number of identical fuel channels in the reactor core. Each channel consists of pressure tube of Zr-2.5 Nb or zircaloy-2 through which high temperature, high pressure primary coolant is passing. The pressure tube contains fuel. Surrounding the pressure tube there is low pressure, cool heavy water (moderator). The moderator is thermally separated from coolant by the tube which is nominally concentric with pressure tube called calandria tube. There are four garter springs in the annular gap between pressure tube and calandria tube. During the life of the reactor there are number of factors by which the pressure tube sags, most important factors are irradiation creep, thermal creep, fuel load etc. Because of the sag of pressure tube it can touch the calandria tube resulting in formation of cold spot. This leads to hydrogen concentration at that spot by which the material at that place becomes brittle and can lead to catastrophic failure of pressure tube. There is no useful access for measurement of annular gap either through the gas annular space or from exterior of calandria tube. So the annular gap was measured from inside surface of pressure tube which is accessible. Eddy current technique was used for finding the gap. The paper describe the details of split coil design of bobbin probe, selection of operating point on normalised impedance diagram by choosing frequency. Experimental results on full scale mock up, and actual gap measurement in reactor channel, are also given. (author). 7 figs

  16. Imaging of blunt chest trauma

    International Nuclear Information System (INIS)

    Prosch, H.; Negrin, L.

    2014-01-01

    Blunt chest trauma is associated with high morbidity and mortality. Consequently, all patients should be evaluated radiologically after blunt chest trauma to allow timely and appropriate treatment. Conventional chest radiographs and computed tomography (CT) are proven modalities with which to evaluate patients after blunt chest trauma. Over the last several years extended focused assessment with sonography for trauma (eFAST) has gained increasing importance for the initial assessment of seriously injured patients. In the acute phase of severely injured patients eFAST examinations are helpful to exclude pneumothorax, hemothorax and hemopericardium. Chest radiographs may also be used to diagnose a pneumothorax or hemothorax; however, the sensitivity is limited and CT is the diagnostic modality of choice to evaluate severely injured patients. (orig.) [de

  17. Anteroposterior chest radiograph vs. chest CT scan in early detection of pneumothorax in trauma patients

    OpenAIRE

    Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M

    2011-01-01

    Abstract Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a tru...

  18. Ultrasonic measurements of chest wall thickness and realistic chest phantom for calibration of Pu lung counting facilities

    International Nuclear Information System (INIS)

    Shirotani, Takashi

    1990-01-01

    There are four important problems for the measurements of chest wall thickness using ultrasonic device: (1) selection of optimum position of transducer and the number of measured points on the chest covered with detector, (2) estimation of adipose-to-muscle ratio in the chest wall, especially for dispersed adipose like 'marbled beef', (3) determination of regression equations for the prediction of chest wall thickness, derived from groups of different body shape, i.e. corpulent and lean, and (4) estimation of effective chest wall thickness involved self-absorption layer of lung tissue, which changes with distribution of activity in the lungs. This quantity can not be measured with ultrasonic device. Realistic chest phantom was developed. The phantom contains removable model organs (lungs, liver, kidneys and heart), model trachea and artificial rib cage, and also includes chest plates that can be placed over the chest to simulate wide range adipose-to-muscle ratio in the chest wall. Various soft tissue substitutes were made of polyurethane with different concentrations of additive, and the rib cage were made of epoxy resin with calcium carbonate. The experimental data have shown that the phantom can be used as a standard phantom for the calibration. (author)

  19. Measuring of tube expansion

    International Nuclear Information System (INIS)

    Vogeleer, J. P.

    1985-01-01

    The expansion of the primary tubes or sleeves of the steam generator of a nuclear reactor plant are measured while the tubes or sleeves are being expanded. A primary tube or sleeve is expanded by high pressure of water which flows through a channel in an expander body. The water is supplied through an elongated conductor and is introduced through a connector on the shank connected to the conductor at its outer end. A wire extends through the mandrel and through the conductor to the end of the connector. At its inner end the wire is connected to a tapered pin which is subject to counteracting forces produced by the pressure of the water. The force on the side where the wire is connected to the conductor is smaller than on the opposite side. The tapered pin is moved in the direction of the higher force and extrudes the wire outwardly of the conductor. The tapered surface of the tapered pin engages transverse captive plungers which are maintained in engagement with the expanding tube or sleeve as they are moved outwardly by the tapered pin. The wire and the connector extend out of the generator and, at its outer end, the wire is connected to an indicator which measures the extent to which the wire is moved by the tapered pin, thus measuring the expansion of the tube or sleeve as it progresses

  20. ANL/CANTIA code for steam generator tube integrity assessment

    International Nuclear Information System (INIS)

    Revankar, S.T.; Wolf, B.; Majumdar, S.; Riznic, J.R.

    2009-01-01

    Steam generator (SG) tubes have an important safety role in CANDU type reactors and Pressurized Water Reactors (PWR) because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear plant. The SG tubes are susceptible to corrosion and damage. A failure of a single steam generator tube, or even a few tubes, would not be a serious safety-related event in a CANDU reactor. The leakage from a ruptured tube is within makeup capacity of the primary heat transport system, so that as long as the operator takes the correct actions, the off-site consequences will be negligible. A sufficient safety margin against tube rupture used to be the basis for a variety of maintenance strategies developed to maintain a suitable level of plant safety and reliability. Several through-wall flaws may remain in operation and potentially contribute to the total primary-to-secondary leak rate. Assessment of the conditional probabilities of tube failures, leak rates, and ultimately risk of exceeding licensing dose limits has been used for steam generator tube fitness-for-service assessment. The advantage of this type of analysis is that it avoids the excessive conservatism typically present in deterministic methodologies. However, it requires considerable effort and expense to develop all of the failure, leakage, probability of detection, and flaw growth distributions and models necessary to obtain meaningful results from a probabilistic model. The Canadian Nuclear Safety Commission (CNSC) recently developed the CANTIA methodology for probabilistic assessment of inspection strategies for steam generator tubes as a direct effect on the probability of tube failure and primary-to-secondary leak rate Recently Argonne National Laboratory has developed tube integrity and leak rate models under Integrated Steam Generator Tube Integrity Program (ISGTIP-2). These models have been incorporated in the ANL/CANTIA code. This paper presents the ANL

  1. Process and device for locating a defective tube, particularly in the tube bundle of a steam generator

    International Nuclear Information System (INIS)

    Denis, Jean.

    1977-01-01

    A process is described for locating a defective tube, particularly in the tube bundle of a steam generator of the reversed U tube kind with the ends connected to a tube plate, marking with the bottom of the generator casing a space separated into two adjacent collectors, respectively for the inlet and outlet of a primary fluid flowing inside the tubes of the bundle, these being externally washed by a secondary vaporizing fluid. In this process a television camera that can be inserted into the casing is used. This process consists in transmitting to a display system outside the generator an image of the tube plate in each collector by means of a directional television camera and then to place over this image a luminous marker to locate the end or the faulty tube [fr

  2. Improvement of the clinical use of computed radiography for mobile chest imaging: Image quality and patient dose

    Science.gov (United States)

    Rill, Lynn Neitzey

    Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for

  3. CANDU steam generator tubing material service experience and allied development

    International Nuclear Information System (INIS)

    Hart, A.E.; Lesurf, J.E.

    1976-01-01

    This paper covers the following aspects for the tube materials in CANDU-PHW steam generators: inservice performance with respect to tube leaks and coolant activity attributable to boiler tube corrosion, selection of tube materials for use with non-boiling and boiling primary coolants, supporting development on corrosion, vibration, fretting wear, tube inspection, leak detection and plugging of defective tubes. (author)

  4. Approach to chest pain and acute myocardial infarction.

    Science.gov (United States)

    Pandie, S; Hellenberg, D; Hellig, F; Ntsekhe, M

    2016-03-01

    Patient history, physical examination, 12-lead electrocardiogram (ECG) and cardiac biomarkers are key components of an effective chest pain assessment. The first priority is excluding serious chest pain syndromes, namely acute coronary syndromes (ACSs), aortic dissection, pulmonary embolism, cardiac tamponade and tension pneumothorax. On history, the mnemonic SOCRATES (Site Onset Character Radiation Association Time Exacerbating/relieving factor and Severity) helps differentiate cardiac from non-cardiac pain. On examination, evaluation of vital signs, evidence of murmurs, rubs, heart failure, tension pneumothoraces and chest infections are important. A 12-lead ECG should be interpreted within 10 minutes of first medical contact, specifically to identify ST elevation myocardial infarction (STEMI). High-sensitivity troponins improve the rapid rule-out of myocardial infarction (MI) and confirmation of non-ST elevation MI (NSTEMI). ACS (STEMI and NSTEMI/unstable anginapectoris (UAP)) result from acute destabilisation of coronary atheroma with resultant complete (STEMI) or subtotal (NSTEMI/UAP) thrombotic coronary occlusion. The management of STEMI patients includes providing urgent reperfusion: primary percutaneous coronary intervention(PPCI) if available, deliverable within 60 - 120 minutes, and fibrinolysis if PPCI is not available. Essential adjunctive therapies include antiplatelet therapy (aspirin, P2Y12 inhibitors), anticoagulation (heparin or low-molecular-weight heparin) and cardiac monitoring.

  5. Non-Invasive Mechanic Ventilation Using in Flail Chest, Caused By Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Serdar Onat

    2008-01-01

    Full Text Available A 75-year-old woman admitted our faculty emergency room with shortness of breath, and chest pain after traffic accident’s second hour. She was diagnosed as bilateral multipl rib fractures, left clavicula fracture, and left flail chest by phsical and radiological examinations. She was transfered to Chest Surgery Depatment’s intensive care unit. The patient was undergone non-invasive mask mechanic ventilation support, because of the decreasing of blood oxygen saturation and increasing of arteriel blood partial carbondioxide pressure. The treatment of non-invasive mechanic ventilation was succesfull for ventilation support. With this report, we would like to attentioned that non-invasive mechanic ventilation for blunt chest trauma patients could be used succesfully and could be used instead of endotracheal invasive mechanic ventilation.

  6. A comparative study of collimation in bedside chest radiography for preterm infants in two teaching hospitals

    International Nuclear Information System (INIS)

    Stollfuss, J.; Schneider, K.; Krüger-Stollfuss, I.

    2015-01-01

    •Potential factors influencing non-optimal image collimation in the setting of bedside chest X-ray in preterm infants were investigated.•A comparable rate of optimal images was observed in two hospitals.•Size, weight or disease severity had no influence on collimation quality.•Unrelated to the years of experience a large variation of the technician in correct collimation was noted (18–86%).•Individualized quality control and education is necessary. Potential factors influencing non-optimal image collimation in the setting of bedside chest X-ray in preterm infants were investigated. A comparable rate of optimal images was observed in two hospitals. Size, weight or disease severity had no influence on collimation quality. Unrelated to the years of experience a large variation of the technician in correct collimation was noted (18–86%). Individualized quality control and education is necessary. Unnecessary exposure of the abdomen, arms or head may lead to a substantial increase of the radiation dose in portable chest X-rays on the neonatal intensive care unit. The objective was to identify potential factors influencing inappropriate exposure of non-thoracic structures in two teaching hospitals. The study analysed 200 consecutive digital chest radiographs in 20 preterm neonates (mean gestation 25 ± 1 weeks). Demographical data, tube settings and exposure parameters were recorded. To grade the collimation, we used a scoring system with a maximum of 12 exposed non-thoracic structures. Length of gestation, age, the radiographer, years of experience in performing X-rays and the number of in situ catheters or lines, were correlated with collimation quality. There was no significant difference between the rates of optimal images obtained in the two hospitals (0.32 vs 0.39, n.s.). Scores showed that most suboptimal images had only mildly reduced image quality (1.40 ± 1.38 vs 1.20 ± 1.43, n.s.). Length of gestation or presence of surgical drains, catheters and

  7. Incidentally Detected Enhancing Breast Lesions on Chest Computed Tomography

    International Nuclear Information System (INIS)

    Lin, Wen Chiung; Hsu, Hsian He; Yu, Jyh Cherng; Hsu, Giu Cheng; Yu, Cheng Ping; Chang, Tsun Hou; Huang, Guo Shu; Li, Chao Shiang

    2011-01-01

    To evaluate the nature and imaging appearance of incidental enhancing breast lesions detected on a routine contrast-enhanced chest CT. Twenty-three patients with incidental enhancing breast lesions on contrast-enhanced chest CT were retrospectively reviewed. The breast lesions were reviewed by unenhanced and enhanced CT, and evaluated by observing the shapes, margins, enhancement patterns and backgrounds of breast lesions. A histopathologic diagnosis or long-term follow-up served as reference standard. Sixteen (70%) patients had malignant breast lesions and seven (30%) had benign lesions. In 10 patients, the breast lesions were exclusively detected on contrast-enhanced CT. Using unenhanced CT, breast lesions with fi broglandular backgrounds were prone to be obscured (p < 0.001). Incidental primary breast cancer showed an non-significant trend of a higher percentage irregular margin (p = 0.056). All of the four incidental breast lesions with non-mass-like enhancement were proven to be malignant. Routine contrast-enhanced chest CT can reveal sufficient details to allow for the detection of unsuspected breast lesions, in which some cases may be proven as malignant. An irregular margin of incidental enhancing breast lesion can be considered a suggestive sign of malignancy

  8. Treatment Option Overview (Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer)

    Science.gov (United States)

    ... diagnosed, tests are done to find out if cancer cells have spread within the ovaries or to other parts of the body. The ... single ovary or fallopian tube. In stage IB, cancer is found inside both ovaries or fallopian tubes. In stage IC, cancer is ...

  9. A Case of Massive Pleural Effusion: Pleurodesis by Bleomycin.

    Science.gov (United States)

    Hasan, R; Khan, O S; Aftabuddin, M; Razzaque, A M; Chowdhury, G A

    2016-04-01

    Malignant pleural effusion is a common complication of primary and metastatic pleural malignancies. Pleurodesis for the management of malignant pleural effusion is intended to achieve symphysis between parietal and visceral pleura, and to prevent relapse of pleural effusion. Many chemical agents are tried to induce inflammation and damage of the pleural mesothelial layer to achieve this symphysis. Hemorrhagic pleural effusion, especially in the right hemithorax commonly occurs as presentation of primary and metastatic pleural malignancies. This case reports massive right-sided hemorrhagic pleural effusion as the sole manifestation of primary lung cancer in a 45 year old man. Patient attended our department of thoracic surgery complaining of cough, shortness of breath and right sided chest pain. A chest X-ray and chest computer tomography (CT) radiograph shows right sided massive pleural effusion. Right sided tube thoracotomy done. Pleural fluid study was done. Fluid for cytopathology was positive for malignant cell. Computed tomography guided fine needle aspiration cytology from right lung lesion was also done. Diagnosis was as small cell carcinoma. Pleural effusion resolved after 9(th) post operative day of chest tube insertion. Bleomycin pleurodesis was done. Day after pleurodesis intra thoracic tube was removed and patient was discharged from hospital on 10(th) Post operative day with an advice to attend the oncology department for further treatment. The protocol of tube thoracostomy and chemical pleurodesis was almost always successful in giving symptomatic relief of respiratory distress for a considerable period of time. However, chemical pleurodesis is not possible in all cases of malignant pleural effusion because it has got potential complication including death.

  10. Cash's textbook of chest, heart and vascular disorders for physiotherapists

    International Nuclear Information System (INIS)

    Downie, P.A.; Innocenti, D.M.; Jackson, S.E.

    1987-01-01

    A very high proportion of the patients treated by physiotherapy will have had a chest radiograph (x-ray) either because their primary disease is pulmonary or there is some long standing heart or lung illness which should be taken into account during the management of an acute problem. This chapter outlines the principles involved in reading the radiograph

  11. Utility of routine postoperative chest radiography in pediatric tracheostomy.

    Science.gov (United States)

    Genther, Dane J; Thorne, Marc C

    2010-12-01

    Routine chest radiography following pediatric tracheostomy is commonly performed in order to evaluate for air-tracking complications. Routine chest radiography affords disadvantages of radiation exposure and cost. The primary objective of this study was to determine the utility of routine postoperative chest radiography following tracheostomy in pediatric patients. Secondary objectives were to compare the rates of postoperative complications by various patient and surgeon characteristics. All infants and children 18 years of age or less (n=421) who underwent tracheostomy at a single tertiary-care medical center from January 2000 to April 2009 were included in the study. A combination of data obtained from billing and administrative systems and review of electronic medical records were recorded and compiled in a database for statistical analysis. Three air-tracking complications (2 pneumothoraces and 1 pneumomediastinum) were identified in our population of 421 pediatric patients, for an incidence of 0.71% (95% CI: 0.1-2.0%). No significant relationships were found between the incidence of air-tracking complication and surgical specialty, patient age, or type of procedure (elective, urgent/emergent). Our study identified a low rate of pneumothorax and pneumomediastinum following pediatric tracheostomy. In all three cases, the pneumothorax was suspected clinically. This finding suggests that postoperative chest radiography should be reserved for cases where there is suspicion of a complication on the basis of intraoperative findings or clinical parameters. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Development of heat treated Zr-2.5% Nb alloy tubes for pressure tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Jha, S.K.; Tonpe, S.

    2011-01-01

    Zr-2.5% Nb alloy is the candidate material for pressure tubes of Pressurized Heavy Water Reactors (PHWR), and are manufactured in cold working condition while heat treated pressure tubes are used in RBMK and FUGEN type of reactors. The diametral creep of these tubes is the life limiting factor. This paper presents the extensive work carried out for the optimization of process parameters to manufacture heat treated Zr-2.5% Nb pressure tubes. Extensive dilactometry study was carried out to establish the transus temperature for the alloy and the effect of soaking temperature and cooling rate on the microstructure was characterized. On the basis of the study, water quenching (at 883 deg C) in the a b region with 20-25% primary a phase was selected, further cold worked, aged and finally autoclaved. Mechanical properties of the finished tubes were found to be comparable to the cold worked route. Large number of full sized tubes of about 700 - 800 mm long was produced to establish the repeatability. (author)

  13. MRI of the Chest

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Chest? What is MRI of the Chest? Magnetic resonance imaging ( ... heart, valves, great vessels, etc.). top of page What are some common uses of the procedure? MR ...

  14. MRI of the Chest

    Medline Plus

    Full Text Available ... to assess the anatomy and function of the heart and its blood flow. Tell your doctor about ... chest cavity, including the mediastinum , chest wall, pleura, heart and vessels, from almost any angle. MRI also ...

  15. Oblique Chest Views as a Routine Part of Skeletal Surveys Performed for Possible Physical Abuse--Is This Practice Worthwhile?

    Science.gov (United States)

    Hansen, Karen Kirhofer; Prince, Jeffrey S.; Nixon, G. William

    2008-01-01

    Objective: To evaluate the utility of oblique chest views in the diagnosis of rib fractures when used as a routine part of the skeletal survey performed for possible physical abuse. Methods: Oblique chest views have been part of the routine skeletal survey protocol at Primary Children's Medical Center since October 2002. Dictated radiology reports…

  16. The impact of chest compression rates on quality of chest compressions : a manikin study

    OpenAIRE

    Field, Richard A.; Soar, Jasmeet; Davies, Robin P.; Akhtar, Naheed; Perkins, Gavin D.

    2012-01-01

    Purpose\\ud Chest compressions are often performed at a variable rate during cardiopulmonary resuscitation (CPR). The effect of compression rate on other chest compression quality variables (compression depth, duty-cycle, leaning, performance decay over time) is unknown. This randomised controlled cross-over manikin study examined the effect of different compression rates on the other chest compression quality variables.\\ud Methods\\ud Twenty healthcare professionals performed two minutes of co...

  17. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  18. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  19. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  20. Pneumothorax and the Value of Chest Radiography after Ultrasound-Guided Thoracocentesis

    International Nuclear Information System (INIS)

    Pihlajamaa, K.; Bode, M.K.; Puumalainen, T.; Lehtimaeki, A.; Marjelund, S.; Tikkakoski, T.

    2004-01-01

    Purpose: To determine the incidence, the operator's experience, and other variables that may influence the development of pneumothorax or re-expansion edema after ultrasound (US)-guided thoracocentesis. Material and Methods: The medical records of 264 procedures in 212 patients who had undergone US-guided thoracocentesis in our radiology department or intensive care unit during the period 1996-2001 were retrospectively reviewed. Results: Post-thoracocentesis pneumothorax occurred in 11 cases, the incidence being 4.2% (11/264). None of the pneumothoraces occurred in the 10 mechanically ventilated patients. All but one patient with pneumothorax were asymptomatic or had only minor symptoms. Chest tube drainage was needed in one patient with a large pneumothorax. No re-expansion edema was recorded, although 1500 ml or more pleural fluid was aspirated in 29 patients. The operator's experience had no effect on the complication rate. Needle size was the only significant variable that contributed to the pneumothorax rate. Conclusion: US-guided thoracocentesis can be done equally as safely by residents as by senior radiologists. The safety and feasibility of the method are evident among mechanically ventilated intensive care patients. Our results do not support the routine use of post-thoracocentesis chest radiography

  1. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  2. Estimating patient dose from CT exams that use automatic exposure control: Development and validation of methods to accurately estimate tube current values.

    Science.gov (United States)

    McMillan, Kyle; Bostani, Maryam; Cagnon, Christopher H; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H; McNitt-Gray, Michael F

    2017-08-01

    The vast majority of body CT exams are performed with automatic exposure control (AEC), which adapts the mean tube current to the patient size and modulates the tube current either angularly, longitudinally or both. However, most radiation dose estimation tools are based on fixed tube current scans. Accurate estimates of patient dose from AEC scans require knowledge of the tube current values, which is usually unavailable. The purpose of this work was to develop and validate methods to accurately estimate the tube current values prescribed by one manufacturer's AEC system to enable accurate estimates of patient dose. Methods were developed that took into account available patient attenuation information, user selected image quality reference parameters and x-ray system limits to estimate tube current values for patient scans. Methods consistent with AAPM Report 220 were developed that used patient attenuation data that were: (a) supplied by the manufacturer in the CT localizer radiograph and (b) based on a simulated CT localizer radiograph derived from image data. For comparison, actual tube current values were extracted from the projection data of each patient. Validation of each approach was based on data collected from 40 pediatric and adult patients who received clinically indicated chest (n = 20) and abdomen/pelvis (n = 20) scans on a 64 slice multidetector row CT (Sensation 64, Siemens Healthcare, Forchheim, Germany). For each patient dataset, the following were collected with Institutional Review Board (IRB) approval: (a) projection data containing actual tube current values at each projection view, (b) CT localizer radiograph (topogram) and (c) reconstructed image data. Tube current values were estimated based on the actual topogram (actual-topo) as well as the simulated topogram based on image data (sim-topo). Each of these was compared to the actual tube current values from the patient scan. In addition, to assess the accuracy of each method in estimating

  3. Evaluation of chest tomosynthesis for the detection of pulmonary nodules: effect of clinical experience and comparison with chest radiography

    Science.gov (United States)

    Zachrisson, Sara; Vikgren, Jenny; Svalkvist, Angelica; Johnsson, Åse A.; Boijsen, Marianne; Flinck, Agneta; Månsson, Lars Gunnar; Kheddache, Susanne; Båth, Magnus

    2009-02-01

    Chest tomosynthesis refers to the technique of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest. In this study, a comparison of chest tomosynthesis and chest radiography in the detection of pulmonary nodules was performed and the effect of clinical experience of chest tomosynthesis was evaluated. Three senior thoracic radiologists, with more than ten years of experience of chest radiology and 6 months of clinical experience of chest tomosynthesis, acted as observers in a jackknife free-response receiver operating characteristics (JAFROC-1) study, performed on 42 patients with and 47 patients without pulmonary nodules examined with both chest tomosynthesis and chest radiography. MDCT was used as reference and the total number of nodules found using MDCT was 131. To investigate the effect of additional clinical experience of chest tomosynthesis, a second reading session of the tomosynthesis images was performed one year after the initial one. The JAFROC-1 figure of merit (FOM) was used as the principal measure of detectability. In comparison with chest radiography, chest tomosynthesis performed significantly better with regard to detectability. The observer-averaged JAFROC-1 FOM was 0.61 for tomosynthesis and 0.40 for radiography, giving a statistically significant difference between the techniques of 0.21 (p<0.0001). The observer-averaged JAFROC-1 FOM of the second reading of the tomosynthesis cases was not significantly higher than that of the first reading, indicating no improvement in detectability due to additional clinical experience of tomosynthesis.

  4. Selective chest imaging for blunt trauma patients: The national emergency X-ray utilization studies (NEXUS-chest algorithm).

    Science.gov (United States)

    Rodriguez, Robert M; Hendey, Gregory W; Mower, William R

    2017-01-01

    Chest imaging plays a prominent role in blunt trauma patient evaluation, but indiscriminate imaging is expensive, may delay care, and unnecessarily exposes patients to potentially harmful ionizing radiation. To improve diagnostic chest imaging utilization, we conducted 3 prospective multicenter studies over 12years to derive and validate decision instruments (DIs) to guide the use of chest x-ray (CXR) and chest computed tomography (CT). The first DI, NEXUS Chest x-ray, consists of seven criteria (Age >60years; rapid deceleration mechanism; chest pain; intoxication; altered mental status; distracting painful injury; and chest wall tenderness) and exhibits a sensitivity of 99.0% (95% confidence interval [CI] 98.2-99.4%) and a specificity of 13.3% (95% CI, 12.6%-14.0%) for detecting clinically significant injuries. We developed two NEXUS Chest CT DIs, which are both highly reliable in detecting clinically major injuries (sensitivity of 99.2%; 95% CI 95.4-100%). Designed primarily to focus on detecting major injuries, the NEXUS Chest CT-Major DI consists of six criteria (abnormal CXR; distracting injury; chest wall tenderness; sternal tenderness; thoracic spine tenderness; and scapular tenderness) and exhibits higher specificity (37.9%; 95% CI 35.8-40.1%). Designed to reliability detect both major and minor injuries (sensitivity 95.4%; 95% CI 93.6-96.9%) with resulting lower specificity (25.5%; 95% CI 23.5-27.5%), the NEXUS CT-All rule consists of seven elements (the six NEXUS CT-Major criteria plus rapid deceleration mechanism). The purpose of this review is to synthesize the three DIs into a novel, cohesive summary algorithm with practical implementation recommendations to guide selective chest imaging in adult blunt trauma patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. PATIENT RADIATION DOSE FROM CHEST X-RAY EXAMINATIONS IN THE WEST BANK-PALESTINE.

    Science.gov (United States)

    Lahham, Adnan; Issa, Ahlam; ALMasri, Hussein

    2018-02-01

    Radiation doses to patients resulting from chest X-ray examinations were evaluated in four medical centers in the West Bank and East Jerusalem-Palestine. Absorbed organ and effective doses were calculated for a total of 428 adult male and female patients by using commercially available Monte Carlo based softwares; CALDOSE-X5 and PCXMC-2.0, and hermaphrodite mathematical adult phantoms. Patients were selected randomly from medical records in the time period from November 2014 to February 2015. A database of surveyed patients and exposure factors has been established and includes: patient's height, weight, age, gender, X-ray tube voltage, electric current (mAs), examination projection (anterior posterior (AP), posterior anterior (PA), lateral), X-ray tube filtration thickness in each X-ray equipment, anode angle, focus to skin distance and X-ray beam size. The average absorbed doses in the whole body from different projections were: 0.06, 0.07 and 0.11 mGy from AP, PA and lateral projections, respectively. The average effective dose for all surveyed patients was 0.14 mSv for all chest X-ray examinations and projections in the four investigated medical centers. The effect of projection geometry was also investigated. The average effective doses for AP, PA and lateral projections were 0.14, 0.07 and 0.22 mSv, respectively. The collective effective dose estimated for the exposed population was ~60 man-mSv. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR.

    Science.gov (United States)

    Park, Sang-Sub

    2014-01-01

    The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).

  7. Chest Reconstruction and Chest Dysphoria in Transmasculine Minors and Young Adults: Comparisons of Nonsurgical and Postsurgical Cohorts.

    Science.gov (United States)

    Olson-Kennedy, Johanna; Warus, Jonathan; Okonta, Vivian; Belzer, Marvin; Clark, Leslie F

    2018-05-01

    Transmasculine youth, who are assigned female at birth but have a gender identity along the masculine spectrum, often report considerable distress after breast development (chest dysphoria). Professional guidelines lack clarity regarding referring minors (defined as people younger than 18 years) for chest surgery because there are no data documenting the effect of chest surgery on minors. To examine the amount of chest dysphoria in transmasculine youth who had had chest reconstruction surgery compared with those who had not undergone this surgery. Using a novel measure of chest dysphoria, this cohort study at a large, urban, hospital-affiliated ambulatory clinic specializing in transgender youth care collected survey data about testosterone use and chest distress among transmasculine youth and young adults. Additional information about regret and adverse effects was collected from those who had undergone surgery. Eligible youth were 13 to 25 years old, had been assigned female at birth, and had an identified gender as something other than female. Recruitment occurred during clinical visits and via telephone between June 2016 and December 2016. Surveys were collected from participants who had undergone chest surgery at the time of survey collection and an equal number of youth who had not undergone surgery. Outcomes were chest dysphoria composite score (range 0-51, with higher scores indicating greater distress) in all participants; desire for chest surgery in patients who had not had surgery; and regret about surgery and complications of surgery in patients who were postsurgical. Of 136 completed surveys, 68 (50.0%) were from postsurgical participants, and 68 (50.0%) were from nonsurgical participants. At the time of the survey, the mean (SD) age was 19 (2.5) years for postsurgical participants and 17 (2.5) years for nonsurgical participants. Chest dysphoria composite score mean (SD) was 29.6 (10.0) for participants who had not undergone chest reconstruction, which

  8. Streak tube development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of a high-speed, high-resolution streak image tube is described. This is one task in the development of a streak camera system with digital electronic readout, whose primary application is for diagnostics in underground nuclear testing. This program is concerned with the development of a high-resolution streak image tube compatible with x-ray input and electronic digital output. The tube must be capable of time resolution down to 100 psec and spatial resolution to provide greater than 1000 resolution elements across the cathode (much greater than presently available). Another objective is to develop the capability to make design changes in tube configurations to meet different experimental requirements. A demountable prototype streak tube was constructed, mounted on an optical bench, and placed in a vacuum system. Initial measurements of the tube resolution with an undeflected image show a resolution of 32 line pairs per millimeter over a cathode diameter of one inch, which is consistent with the predictions of the computer simulations. With the initial set of unoptmized deflection plates, the resolution pattern appeared to remain unchanged for static deflections of +- 1/2-inch, a total streak length of one inch, also consistent with the computer simulations. A passively mode-locked frequency-doubled dye laser is being developed as an ultraviolet pulsed light source to measure dynamic tube resolution during streaking. A sweep circuit to provide the deflection voltage in the prototype tube has been designed and constructed and provides a relatively linear ramp voltage with ramp durations adjustable between 10 and 1000 nsec

  9. Ultrasonography of chest wall lesion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H. [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  10. Ultrasonography of chest wall lesion

    International Nuclear Information System (INIS)

    Park, Cheol Min; Kim, C. H.; Cha, I. H.; Chung, K. B.; Ser, W. H.; Choi, Y. H.

    1989-01-01

    Thirty-one patients with chest wall diseases were studied with ultrasound to evaluate its role in chest wall lesions. There were eight infectious conditions, 9 benign tumors, 11 malignant lesions and 3 miscellaneous cases. Diffuse chest wall thickening with heterogeneous echogenicity and obliteration of subcutaneous fat layer are findings of acute infection. In cases of tuberculous smpyema necessitates, pleural abnormality extended to the chest wall through intercostal space. Benign tumors were well demarcated, except in 4 cases of lipoma/lipomatosis. Malignant lesions showed irregular soft tissue masses, bone destruction, pleural effusion and subcutaneous invasion. Multiple enlarged lymph nodes were also shown. Ultrasound can demonstrate te internal structure, extent, depth and associated findings such as pleural effusion, bone destruction and peripheral lung involvement. Ultrasound is not only safe, non-invasive and an effective diagnostic imaging modality for chest wall disease, but can also guide aspiration or biopsy for pathologic diagnosis

  11. Fractured Tracheostomy Tube in Left Main Bronchus with No Mouth Opening: An Anaesthetic Challenge

    Directory of Open Access Journals (Sweden)

    Arghya Mukherjee

    2014-10-01

    Full Text Available Foreign body aspiration is a serious medical condition that demands prompt diagnosis and treatment to prevent fatal complications. This is a case report of a 42 year male with history of surgery for carcinoma tongue, hemiglossectomy and tracheostomy. He presented with dislodged fractured metallic tracheostomy tube in left main bronchus. Patient was breathing through stenosed tracheostomy stoma with bilateral normal air entry in chest. He was haemodynamically stable. Rigid bronchoscopic removal was impossible due to no mouth opening. After securing airway, general anaesthesia was induced and thoracotomy was performed to remove dislodged tube. Proper planning and coordinated team work resulted in good outcome.

  12. Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma.

    Science.gov (United States)

    Wilkerson, R Gentry; Stone, Michael B

    2010-01-01

    Supine anteroposterior (AP) chest radiographs in patients with blunt trauma have poor sensitivity for the identification of pneumothorax. Ultrasound (US) has been proposed as an alternative screening test for pneumothorax in this population. The authors conducted an evidence-based review of the medical literature to compare sensitivity of bedside US and AP chest radiographs in identifying pneumothorax after blunt trauma. MEDLINE and EMBASE databases were searched for trials from 1965 through June 2009 using a search strategy derived from the following PICO formulation of our clinical question: patients included adult (18 + years) emergency department (ED) patients in whom pneumothorax was suspected after blunt trauma. The intervention was thoracic ultrasonography for the detection of pneumothorax. The comparator was the supine AP chest radiograph during the initial evaluation of the patient. The outcome was the diagnostic performance of US in identifying the presence of pneumothorax in the study population. The criterion standard for the presence or absence of pneumothorax was computed tomography (CT) of the chest or a rush of air during thoracostomy tube placement (in unstable patients). Prospective, observational trials of emergency physician (EP)-performed thoracic US were included. Trials in which the exams were performed by radiologists or surgeons, or trials that investigated patients suffering penetrating trauma or with spontaneous or iatrogenic pneumothoraces, were excluded. The methodologic quality of the studies was assessed. Qualitative methods were used to summarize the study results. Data analysis consisted of test performance (sensitivity and specificity, with 95% confidence intervals [CIs]) of thoracic US and supine AP chest radiography. Four prospective observational studies were identified, with a total of 606 subjects who met the inclusion and exclusion criteria. The sensitivity and specificity of US for the detection of pneumothorax ranged from

  13. DEVELOPMENT OF A CHEST FREEZER – OPTIMUM DESIGN OF AN EVAPORATOR COIL

    Directory of Open Access Journals (Sweden)

    K. Kalyani Radha

    2012-06-01

    Full Text Available In a country such as India, food grains, fruit, vegetables, meat, poultry and fish, are very susceptible to microbial contamination and spoilage and require stringent preservation methods. One such method is by the use of a chest freezer for the storage of frozen food. This investigation considers different loads and design parameters for the development of a chest freezer using R134a as the working fluid. Experimental designs of an evaporator coil, condenser coil and capillary tube are investigated through the development of storage periods in terms of steady state and cyclic performance, by optimising the quantity of refrigerant charge, with strict adherence to the standards and requirement for maintaining an internal temperature of -23 °C at 43 °C ambient. Cyclic load performance tests optimise the performance of individual components selected for the design of a chest freezer. The system selection has a highly balanced performance with R134a and showed 118 kJ/kg cooling capacity with 8.42 coefficient of performance (COP. By the replacement of R134a, temperatures of -23 °C are maintained inside the freezer cabinet with low power consumption and an increase in the net refrigerating effect, which in turn increases the COP. The system design has optimum efficiency with moderate costs by optimising the length and diameter of the evaporator coil, i.e., 34.15 m and 7.94 mm, respectively.

  14. Repair of chest wall defects after irradiation for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, L E

    1976-03-01

    A simple technique using a contralateral deltopectoral flap is described for the immediate repair of defects of the chest wall resulting from excision of radionecrosis or persistent tumour after radiotherapy. Successful use in 3 consecutive cases has shown that the deltopectoral flap may be rotated through a full 180/sup 0/ without compromise of blood supply and that primary healing may be obtained.

  15. The impact of the AEC mode of tube current on the dose at CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Kim, Kwang Cheol [Dept. of of Nuclear Engineering, Chosun University,Gwangju (Korea, Republic of)

    2016-11-15

    In this study, the automatic exposure control (AEC) modes of tube current (SIEMENSCare Dose 4D and GE AEC mode) that CT manufacturers are using was applied to neck, chest and abdomen in order to determine the difference in the respective dose parameters (CTDIvol, DLP and mSv) resulting from the dose reduction. Equipment in use at C university adopted Care Dose 4D of Siemens and AEC mode of General Electric (GE), and the x-ray exposure conditions were adjusted to be as identical as possible between the experiments. For the assessment of the dose reduction, the differences between the doses with and without the use of the tube current AEC mode by the respective manufacturer were measured for each body part including neck, chest and abdomen of a human phantom, Rando Phantom (Art-200x, Fluke Biomedical, USA). First, the assessment of SIEMENS-Care Dose 4D yielded the following results. At the neck, the automatic exposure control resulted in a 3.3% reduction in CTDIvol and DLP, and a 3% reduction in the effective dose, mSv, compared to manual exposure control. The automatic exposure control at the chest displayed the reduction in CTDIvol and DLP by 25.5%, and in the effective dose, mSv, by 25.4% compared to the manual exposure control. In case of abdomen, CTDIvol and DLP were shown to be reduced by 16%, and the effective dose (mSv) by 16.3% under the automatic exposure control compared to the manual exposure. Second, the assessment results of GE AEC mode are as follows. The automatic exposure control at the neck resulted in a 45.1% reduction in CTDIvol and DLP, and a 44.7% reduction in the effective dose (mSv) in comparison to the manual exposure control. At the chest, the automatic exposure control displayed a 47.6% reduction in CTDIvol and DLP, and a 47.5% reduction in the effective dose, mSv, compared to the manual exposure control. At the abdomen, it was shown that CTDIvol and DLP were reduced by 26.9%, and the effective dose (mSv) by 26.8% under the automatic

  16. The impact of the AEC mode of tube current on the dose at CT scans

    International Nuclear Information System (INIS)

    Moon, Il Bong; Dong, Kyung Rae; Kim, Kwang Cheol

    2016-01-01

    In this study, the automatic exposure control (AEC) modes of tube current (SIEMENSCare Dose 4D and GE AEC mode) that CT manufacturers are using was applied to neck, chest and abdomen in order to determine the difference in the respective dose parameters (CTDIvol, DLP and mSv) resulting from the dose reduction. Equipment in use at C university adopted Care Dose 4D of Siemens and AEC mode of General Electric (GE), and the x-ray exposure conditions were adjusted to be as identical as possible between the experiments. For the assessment of the dose reduction, the differences between the doses with and without the use of the tube current AEC mode by the respective manufacturer were measured for each body part including neck, chest and abdomen of a human phantom, Rando Phantom (Art-200x, Fluke Biomedical, USA). First, the assessment of SIEMENS-Care Dose 4D yielded the following results. At the neck, the automatic exposure control resulted in a 3.3% reduction in CTDIvol and DLP, and a 3% reduction in the effective dose, mSv, compared to manual exposure control. The automatic exposure control at the chest displayed the reduction in CTDIvol and DLP by 25.5%, and in the effective dose, mSv, by 25.4% compared to the manual exposure control. In case of abdomen, CTDIvol and DLP were shown to be reduced by 16%, and the effective dose (mSv) by 16.3% under the automatic exposure control compared to the manual exposure. Second, the assessment results of GE AEC mode are as follows. The automatic exposure control at the neck resulted in a 45.1% reduction in CTDIvol and DLP, and a 44.7% reduction in the effective dose (mSv) in comparison to the manual exposure control. At the chest, the automatic exposure control displayed a 47.6% reduction in CTDIvol and DLP, and a 47.5% reduction in the effective dose, mSv, compared to the manual exposure control. At the abdomen, it was shown that CTDIvol and DLP were reduced by 26.9%, and the effective dose (mSv) by 26.8% under the automatic

  17. WWER steam generator tube structural and leakage integrity

    International Nuclear Information System (INIS)

    Splichal, K.; Krhounek, Vl.; Otruba, J.; Ruscak, M.

    1998-01-01

    The integrity of heat exchange tubes may influence the lifetime of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirements are to assure very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evaluation and heat exchange tubes plugging. The stress corrosion cracking and pitting are the main corrosion damages of WWER heat exchange tubes and are initiated from the outer surface. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through wall cracks, oriented preferentially in the axial direction. The paper presents the leakage and plugging limits for WWER steam generators, which have been determined from leak tests and burst tests. The tubes with axial part-through and through-wall defects have been used. The permissible value of primary to secondary leak rate was evaluated with respect to permissible axial through-wall defect size of WWER 440 and 1000 steam generator tubes. Blocking of the tube cracks by corrosion product particles and other compounds reduces the primary to secondary leak rate. The plugging limits involve the following factors: permissible tube wall thickness which determine further operation of the tubes with defects and assures their integrity under operating conditions and permissible size of a through-wall crack which is sufficiently stable under normal and accident conditions in relation to the critical crack length. For the evaluation of burst test of heat exchange tubes with longitudinal through-wall defects the instability criterion has been used and the dependence of the normalised burst pressure on the normalised length of an axial through-wall defect has been determined. The validity of the criterion of instability for WWER tubes with through

  18. Possibility of clinical usefulness of heavy metal filter combinations in digital chest radiography

    International Nuclear Information System (INIS)

    Kawaji, Yasuyuki; Ideguchi, Tadamitsu; Ikeda, Hirotaka; Sakamoto, Hiromi; Higashida, Yoshiharu; Toyofuku, Fukai

    2003-01-01

    We have investigated the potential usefulness of the heavy metal filters with higher atomic numbers by comparing their patient exposures, tube loadings, radiographic contrasts, and the visual detection of simulated nodules in computed radiography (CR) with those of a combination of copper and aluminum. Seven heavy metal filters were used for this study. As for a tungsten filter, two filters different in thickness were used. One is 0.05 mm thick, and the other 0.10 mm. The other metal filters were respectively combined with a tungsten filter with a thickness of 0.05 mm. Among the all filters, tungsten with 0.1 mm thick and tungsten with 0.05 mm+barium which showed larger advantages in patient exposure and tube loading than those of the other filters were used for detection task of simulated nodules in chest radiography. The results indicated that the use of heavy metal filters can improve detectability of simulated nodules over that obtainable with conventional copper and aluminum filter. (author)

  19. Early detection of thoracic spine fracture in the multiple-trauma patient: Findings on the initial anteroposterior chest radiograph

    International Nuclear Information System (INIS)

    Lawrason, J.N.; Novelline, R.A.; Rhea, J.T.; DeLuca, S.A.; Sacknoff, R.

    1987-01-01

    In the unconscious, multiple-trauma patient, thoracic spine fractures may be initially overlooked due to a combination of immediate concern given to more obvious injuries and a failure to carefully scrutinize the initial, often anteroposterior (AP) and portable chest radiograph. In a recent review of their cases the authors retrospectively identified primary or secondary signs of thoracic spine fracture in 80% of the initial chest radiographs of multiple-trauma patients with this injury. This paper reviews these obvious and subtle, bony and soft-tissue AP chest radiograph signs of thoracic spine fracture and compare them with matching spine radiographs, tomography, and CT

  20. Pneumopericardium and Deep Sulcus Sign After Blunt Chest Trauma

    Directory of Open Access Journals (Sweden)

    Taner Tarladacalisir

    2014-12-01

    Full Text Available Pneumopericardium is defined as air between the leaves of the pericardium, which is usually self-limited. In tension pneumopericardium, however, rapid fluid resuscitation and haemodynamic monitoring followed by pericardial fenestration and drainage should be performed. A 49-year-old male falling from height was brought to the emergency room. On chest X-ray in supine position, a deep sulcus sign and subcutaneous emphysema with multiple rib fractures were detected. At computerized tomography, pericardial free air, right pneumothorax and subcutaneous emphysema were detected. A tube thoracostomy was applied to the patient. During follow-up with cardiac enzymes in the intensive care unit, no tension pneumopericardium developed, and subcutaneous emphysema regressed. A control computerized tomography scan showed a complete regression in the pneumopericardium on the tenth day.

  1. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik

    ,3 mAs and SID SID of 180 centimetres using a phantom and lithium fluoride thermo luminescence dosimeter (TLD). Dose to risk organs mamma, thyroid and colon are measured at different collimations with one-centimetre steps. TLD results are used to estimate dose reduction for different collimations...... at the conference. Conclusion: Collimation improvement in basic chest radiography can reduce the radiation to female patients at chest x-ray examinations....

  2. Are routine repeat chest x-rays before leaving the trauma room useful?

    NARCIS (Netherlands)

    Lemmers, M.; Saltzherr, T. P.; Beenen, L. F. M.; Ponsen, K. J.; Goslings, J. C.

    2010-01-01

    Several guidelines advocate multiple chest x-rays during primary resuscitation of trauma patients. Some local hospital protocols include a repeat x-ray before leaving the trauma resuscitation room (TR). The purpose of this study was to determine the value of routine repeat x-rays. One-year data of

  3. Long-Term Clinical Impact of Coronary CT Angiography in Patients With Recent Acute-Onset Chest Pain

    DEFF Research Database (Denmark)

    Linde, Jesper J; Hove, Jens D; Sørgaard, Mathias

    2015-01-01

    . BACKGROUND: The prognostic implications of a coronary CTA-guided treatment strategy have not been compared in a randomized fashion to standard care in patients referred for acute-onset chest pain. METHODS: Patients with acute chest pain but normal electrocardiograms and troponin values were randomized...... to treatment guided by either coronary CTA or standard care (bicycle exercise electrocardiogram or myocardial perfusion imaging). In the coronary CTA-guided group, a functional test was included in cases of nondiagnostic coronary CTA images or coronary stenoses of borderline severity. The primary endpoint...... electrocardiograms and troponin values compared to standard care with a functional test. (Cardiac-CT in the Treatment of Acute Chest Pain [CATCH]; NCT01534000)....

  4. 46 CFR 169.743 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 169.743 Section 169.743... Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.743 Portable magazine chests. Portable magazine chests must be marked in letters at least 3 inches high: “PORTABLE MAGAZINE CHEST...

  5. Quality of Life and Care Needs of Patients With Persistent or Recurrent Ovarian Cancer, Fallopian Tube Cancer, or Peritoneal Cancer

    Science.gov (United States)

    2017-05-03

    Anxiety; Fatigue; Nausea and Vomiting; Neurotoxicity Syndrome; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma; Stage I Ovarian Cancer; Stage IA Fallopian Tube Cancer; Stage IB Fallopian Tube Cancer; Stage IC Fallopian Tube Cancer; Stage II Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIB Fallopian Tube Cancer; Stage IIC Fallopian Tube Cancer; Stage III Ovarian Cancer; Stage III Primary Peritoneal Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIC Fallopian Tube Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  6. Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons.

    Science.gov (United States)

    Lopez-Rendon, Xochitl; Zhang, Guozhi; Coudyzer, Walter; Develter, Wim; Bosmans, Hilde; Zanca, Federica

    2017-11-01

    To compare the lung and breast dose associated with three chest protocols: standard, organ-based tube current modulation (OBTCM) and fast-speed scanning; and to estimate the error associated with organ dose when modelling the longitudinal (z-) TCM versus the 3D-TCM in Monte Carlo simulations (MC) for these three protocols. Five adult and three paediatric cadavers with different BMI were scanned. The CTDI vol of the OBTCM and the fast-speed protocols were matched to the patient-specific CTDI vol of the standard protocol. Lung and breast doses were estimated using MC with both z- and 3D-TCM simulated and compared between protocols. The fast-speed scanning protocol delivered the highest doses. A slight reduction for breast dose (up to 5.1%) was observed for two of the three female cadavers with the OBTCM in comparison to the standard. For both adult and paediatric, the implementation of the z-TCM data only for organ dose estimation resulted in 10.0% accuracy for the standard and fast-speed protocols, while relative dose differences were up to 15.3% for the OBTCM protocol. At identical CTDI vol values, the standard protocol delivered the lowest overall doses. Only for the OBTCM protocol is the 3D-TCM needed if an accurate (<10.0%) organ dosimetry is desired. • The z-TCM information is sufficient for accurate dosimetry for standard protocols. • The z-TCM information is sufficient for accurate dosimetry for fast-speed scanning protocols. • For organ-based TCM schemes, the 3D-TCM information is necessary for accurate dosimetry. • At identical CTDI vol , the fast-speed scanning protocol delivered the highest doses. • Lung dose was higher in XCare than standard protocol at identical CTDI vol .

  7. Delayed pneumothorax complicating minor rib fracture after chest trauma.

    Science.gov (United States)

    Lu, Ming-Shian; Huang, Yao-Kuang; Liu, Yun-Hen; Liu, Hui-Ping; Kao, Chiung-Lun

    2008-06-01

    Pneumothorax (PTX) after trauma is a preventable cause of death. Drainage procedures such as chest tube insertion have been traditionally advocated to prevent fatal tension PTX. We evaluated the safety of close observation in patients with delayed PTX complicating rib fracture after minor chest trauma. Adult patients (>18 years) with a diagnosis of chest trauma and 3 or fewer fractured ribs were reviewed. Case patients were divided according to age, location and number of fractured ribs, mechanism of trauma, and initial pulmonary complication after thoracic trauma for comparative analysis. There were 207 male (70.2%) and 88 female (29.8%) patients whose ages ranged from 18 to 93 years (median, 55 years). The mechanisms of trauma were a motor vehicle accident in 207 patients, falls in 66, pedestrian injury in 10, and assaults in 14. Ninety-five patients sustained 1 rib fracture, 95 had 2 rib fractures, and 105 suffered 3 rib fractures. Right-sided injury occurred in 164 cases, left-sided injury did in 127, and bilateral injury did in 4. The most frequent location of rib fractures was from the fourth rib to the ninth rib. The initial pulmonary complications after trauma were PTX in 16 patients, hemothorax in 43, pneumohemothorax in 14, lung contusion in 75, and isolated subcutaneous emphysema (SubcEmph) in 33. Thirty percent of the patients (n = 5/16) who presented with traumatic PTX were observed safely without drainage. Delayed PTX was recorded in 16 patients, occurring mostly during the first 2 days of their admission. Associated extrathoracic injury was recorded in 189 patients. The mean hospital stay of the patients was 7.66 days. Longer hospital stay was related to increasing number of fractured ribs, need for thoracic drainage, and the presence of associated extrathoracic injury. The mortality rate for the entire group was 2%. The presence of SubcEmph was the only risk factor associated with the development of delayed PTX. Patients sustaining blunt chest

  8. MRI of the Chest

    Medline Plus

    Full Text Available ... chest is performed to: assess abnormal masses, including cancer of the lungs or other tissues, which either cannot be assessed ... in diagnosing a broad range of conditions, including cancer, heart and ... tissues, except for lung abnormalities where Chest CT is a preferred imaging ...

  9. Nodule detection in digital chest radiography: Summary of the radius chest trial

    International Nuclear Information System (INIS)

    Haakansson, M.; Baath, M.; Boerjesson, S.; Kheddache, S.; Grahn, A.; Ruschin, M.; Tingberg, A.; Mattson, S.; Maansson, L. G.

    2005-01-01

    As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging' - governed by the Radiological Imaging Unification Strategies (RADIUS) Group - a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule. (authors)

  10. Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chenying; Wang, Zufei; Ji, Jiansong; Wang, Hailin; Hu, Xianghua; Chen, Chunmiao [Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000 (China)

    2015-11-01

    To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.

  11. Probabilistic methodology for assessing steam generator tube inspection - Phase II: CANTIA - a probabilistic method for assessing steam generator tube inspections

    International Nuclear Information System (INIS)

    Harris, J.E.; Gorman, J.A.; Turner, A.P.L.

    1997-03-01

    The objectives of this project were to develop a computer-based method for probabilistic assessment of inspection strategies for steam generator tubes, and to document the source code and to provide a user's manual for it. The program CANTIA was created to fulfill this objective, and the documentation and verification of the code is provided in this volume. The user's manual for CANTIA is provided as a separate report. CANTIA uses Monte Carlo techniques to determine approximate probabilities of steam generator tube failures under accident conditions and primary-to-secondary leak rates under normal and accident conditions at future points in time. The program also determines approximate future flaw distributions and non-destructive examination results from the input data. The probabilities of failure and leak rates and the future flaw distributions can be influenced by performing inspections of the steam generator tubes at some future points in time, and removing defective tubes from the population. The effect of different inspection and maintenance strategies can therefore be determined as a direct effect on the probability of tube failure and primary-to-secondary leak rate

  12. Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall

    International Nuclear Information System (INIS)

    Kim, Tae Jung; Lee, Kyoung Ho; Kim, Bohyoung; Kim, Kil Joong; Chun, Eun Ju; Bajpai, Vasundhara; Kim, Young Hoon; Hahn, Seokyung; Lee, Kyung Won

    2009-01-01

    Objective: To estimate the visually lossless threshold (VLT) for the Joint Photographic Experts Group (JPEG) 2000 compression of chest CT images and to demonstrate the variance of the VLT between the lung and mediastinum/chest wall. Subjects and methods: Eighty images were compressed reversibly (as negative control) and irreversibly to 5:1, 10:1, 15:1 and 20:1. Five radiologists determined if the compressed images were distinguishable from their originals in the lung and mediastinum/chest wall. Exact tests for paired proportions were used to compare the readers' responses between the reversible and irreversible compressions and between the lung and mediastinum/chest wall. Results: At reversible, 5:1, 10:1, 15:1, and 20:1 compressions, 0%, 0%, 3-49% (p < .004, for three readers), 69-99% (p < .001, for all readers), and 100% of the 80 image pairs were distinguishable in the lung, respectively; and 0%, 0%, 74-100% (p < .001, for all readers), 100%, and 100% were distinguishable in the mediastinum/chest wall, respectively. The image pairs were less frequently distinguishable in the lung than in the mediastinum/chest wall at 10:1 (p < .001, for all readers) and 15:1 (p < .001, for two readers). In 321 image comparisons, the image pairs were indistinguishable in the lung but distinguishable in the mediastinum/chest wall, whereas there was no instance of the opposite. Conclusion: For JPEG2000 compression of chest CT images, the VLT is between 5:1 and 10:1. The lung is more tolerant to the compression than the mediastinum/chest wall.

  13. Regional variance of visually lossless threshold in compressed chest CT images: Lung versus mediastinum and chest wall

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Jung [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of); Lee, Kyoung Ho [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of)], E-mail: kholee@snubhrad.snu.ac.kr; Kim, Bohyoung; Kim, Kil Joong; Chun, Eun Ju; Bajpai, Vasundhara; Kim, Young Hoon [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of); Hahn, Seokyung [Medical Research Collaborating Center, Seoul National University Hospital, 28 Yongon-dong, Chongno-gu, Seoul 110-744 (Korea, Republic of); Seoul National University College of Medicine (Korea, Republic of); Lee, Kyung Won [Department of Radiology, Seoul National University Bundang Hospital, 300 Gumi-dong, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707 (Korea, Republic of); Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center (Korea, Republic of)

    2009-03-15

    Objective: To estimate the visually lossless threshold (VLT) for the Joint Photographic Experts Group (JPEG) 2000 compression of chest CT images and to demonstrate the variance of the VLT between the lung and mediastinum/chest wall. Subjects and methods: Eighty images were compressed reversibly (as negative control) and irreversibly to 5:1, 10:1, 15:1 and 20:1. Five radiologists determined if the compressed images were distinguishable from their originals in the lung and mediastinum/chest wall. Exact tests for paired proportions were used to compare the readers' responses between the reversible and irreversible compressions and between the lung and mediastinum/chest wall. Results: At reversible, 5:1, 10:1, 15:1, and 20:1 compressions, 0%, 0%, 3-49% (p < .004, for three readers), 69-99% (p < .001, for all readers), and 100% of the 80 image pairs were distinguishable in the lung, respectively; and 0%, 0%, 74-100% (p < .001, for all readers), 100%, and 100% were distinguishable in the mediastinum/chest wall, respectively. The image pairs were less frequently distinguishable in the lung than in the mediastinum/chest wall at 10:1 (p < .001, for all readers) and 15:1 (p < .001, for two readers). In 321 image comparisons, the image pairs were indistinguishable in the lung but distinguishable in the mediastinum/chest wall, whereas there was no instance of the opposite. Conclusion: For JPEG2000 compression of chest CT images, the VLT is between 5:1 and 10:1. The lung is more tolerant to the compression than the mediastinum/chest wall.

  14. Flaw analysis in steam generator tube

    International Nuclear Information System (INIS)

    Hutin, J.P.; Billon, F.

    1985-08-01

    Operating more than 30 PWR units, Electricite de France has to face several steam generator tube problems. One of the most serious difficulties is the stress corrosion cracking due to primary fluid, just above the tube sheet, in the roll transition region. With regard to availability it is, of course, a major concern; with regard to safety, the point is that tube rupture should be preceded by a significant primary-to-secondary leak during normal operation so that the reactor should be shut down before failure occurs. The demonstration of this assessment asks for experimental and analytical evidences. In 1981, Elecricite de France started a comprehensive program on that subject. A general description of this program and the main results are to be presented during the SMIRT-8 Conference. The purpose of the present paper is to develop in greater detail the analytical part of the work

  15. Effect of chest tube position on the success rate of pleurodesis: A retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Tomoyasu Takemura

    2017-10-01

    Conclusions: In malignant pleural effusion, the success rates of pleurodesis may be similar regardless of the position of the tube. However, this is a retrospective study with insufficient participants. Hence, further investigation is required.

  16. 14 French pigtail catheters placed by surgeons to drain blood on trauma patients: is 14-Fr too small?

    Science.gov (United States)

    Kulvatunyou, Narong; Joseph, Bellal; Friese, Randall S; Green, Donald; Gries, Lynn; O'Keeffe, Terence; Tang, Andy L; Wynne, Julie L; Rhee, Peter

    2012-12-01

    Small 14F pigtail catheters (PCs) have been shown to drain air quite well in patients with traumatic pneumothorax (PTX). But their effectiveness in draining blood in patients with traumatic hemothorax (HTX) or hemopneumothorax (HPTX) is unknown. We hypothesized that 14F PCs can drain blood as well as large-bore 32F to 40F chest tubes. We herein report our early case series experience with PCs in the management of traumatic HTX and HPTX. We prospectively collected data on all bedside-inserted PCs in patients with traumatic HTX or HPTX during a 30-month period (July 2009 through December 2011) at our Level I trauma center. We then compared our PC prospective data with our trauma registry-derived retrospective chest tube data (January 2008 through December 2010) at our center. Our primary outcome of interest was the initial drainage output. Our secondary outcomes were tube duration, insertion-related complications, and failure rate. For our statistical analysis, we used the unpaired Student's t-test, χ test, and Wilcoxon rank-sum test; we defined significance by a value of p tubes. Our PC group had a higher rate of blunt mechanism injuries than our chest tube group did (83 vs. 62%; p = 0.01). The mean initial output was similar between our PC group (560 ± 81 mL) and our chest tube group (426 ± 37 mL) (p = 0.13). In the PC group, the tube was inserted later (median, Day 1; interquartile range, Days 0-3) than the tube inserted in our chest tube group (median, Day 0; interquartile range, Days 0-0) (p Tube duration, rate of insertion-related complications, and failure rate were all similar. In our early experience, 14F PCs seemed to drain blood as well as large-bore chest tubes based on initial drainage output and other outcomes studied. In this early phase, we were being selective in inserting PCs in only stable blunt trauma patients, and PCs were inserted at a later day from the time of the initial evaluation. In the future, we will need a larger sample size and

  17. Fracture mechanics analysis of the steam generator tube after shot peening

    International Nuclear Information System (INIS)

    Shin, Kyu In; Jhung, Myung Jo; Choi, Young Hwan; Park, Jai Hak

    2003-01-01

    One of the main degradation of steam generator tubes is stress corrosion cracking induced by residual stress. The resulting damages can cause tube bursting or leakage of the primary water which contained radioactivity. Primary water stress corrosion crack occurs at the location of tube/tubesheet hard rolled transition zone. In order to investigate the effect of shot peening on stress corrosion cracking, stress intensity factors are calculated for the crack which is located in the induced residual stress field

  18. Surgical treatment of chest instability

    International Nuclear Information System (INIS)

    Kitka, M.; Masek, M.

    2015-01-01

    Fractures of the ribs is the most common thoracic injury after blunt trauma. Chest wall instability (flail chest) is a common occurrence in the presence of multiple ribs fracture. Unilateral or bilateral fractures more ribs anteriorly or posteriorly will produce enough instability that paradoxical respiratory motion results in hypoventilation of an unacceptable degree. Open approach and surgical stabilisation of the chest preserved pulmonary function, improved pain control, minimized posttraumatic deformities and shorter back to work time. (author)

  19. Clinical Utility of Chest Computed Tomography in Patients with Rib Fractures CT Chest and Rib Fractures

    OpenAIRE

    Chapman, Brandon C.; Overbey, Douglas M.; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T.; French, Andrew; Johnson, Jeffrey L.; Burlew, Clay C.; Barnett, Carlton; Moore, Ernest E.; Pieracci, Fredric M.

    2016-01-01

    Background Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. Objectives The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Methods Retrospective coho...

  20. Chest pain

    International Nuclear Information System (INIS)

    Martinez A, Juan Carlos; Saenz M, Oscar; Martinez M, Camilo; Gonzales A Francisco; Nicolas R, Jose; Vergara V, Erika P; Pereira G, Alberto M

    2010-01-01

    In emergency departments, chest pain is one of the leading motives of consultation. We thus consider it important to review aspects such as its classification, causes, and clinical profiles. Initial assessment should include a full clinical history comprising thorough anamnesis and physical examination. Adequate interpretation of auxiliary tests, ordered in accordance with suspected clinical conditions, should lead to accurate diagnosis. We highlight certain symptoms and clinical signs, ECG and X-ray findings, cardiac bio markers, arterial blood gases, and CT-scanning. Scores of severity and prognosis such as TIMI are assessed. Optimal treatment of the clinical conditions leading to chest pain depends on adequate initial approach and assessment.

  1. Blunt chest trauma in a non-specialist centre: Right treatment, right place?

    Science.gov (United States)

    Maher, Lesley; Jayathissa, Sisira

    2016-12-01

    To compare patient characteristics, management and outcomes for patients admitted with isolated blunt chest trauma, managed by medical or surgical teams. We reviewed adult patients admitted with blunt chest trauma between 1 September 2006 and 31 August 2011 to a secondary hospital in New Zealand. Inclusion criteria were: blunt chest trauma, with at least one radiologically demonstrated rib fracture. The primary outcome was in-hospital mortality, and secondary outcomes were development of pneumonia, and use of analgesia. Seventy-two patients were included. Thirty-three patients were managed by medical teams and 39 by surgical teams. In-hospital mortality was greater amongst medical patients 5/33 (15%) versus surgical 0/39 (0%); P = 0.012. Pneumonia occurred in 15/33 (45%); medical patients versus surgical 2/39 (5%), P trauma fall compared to surgically managed patients (28/33 [85%] vs 9/39 [27%]; P chest trauma, those managed by medical teams were older, had more comorbidities and were more likely to have become injured with a low trauma fall than those managed by surgical teams. They had less access to analgesic options, developed pneumonia more often and had higher mortality. © 2016 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  2. Tube thoracostomy: Primary management option for empyema thoracis in children

    Directory of Open Access Journals (Sweden)

    Rajendra K Ghritlaharey

    2012-01-01

    Full Text Available Aim: The aim of this study was to review our experience with tube thoracostomy in the management of empyema thoracis in children. Patients and Methods: This retrospective study included 46 children (26 boys and 20 girls who were admitted and managed for empyema thoracis, between January 1, 2010 and December 31, 2010 at the author′s department of paediatric surgery. Results: During the last 12 months, 46 children aged below 12 years were treated for empyema thoracis: Five (10.86% were infants, 22 (47.82% were 1 to 5 years and 19 (41.30% were 6 to 12 years of age. All the patients presented with complaints of cough, fever and breathlessness of variable durations. Twenty three (50% children had history of pneumonia and treatment prior to development of empyema. Thirty five (76.08% children had right-sided and 11 (23.91% had left-sided empyema. Thirty nine (84.78% children were successfully treated with tube thoracostomy, systemic antibiotics and other supportive measures. Seven (15.21% children failed to respond with above and needed decortications. Most commonly isolated bacteria were Pseudomonas (n = 12 and Staphylococcus aureus (n = 7. The average length of hospital stay in patients with tube thoracostomy was 15.35 days, and in patients who needed decortications was 16.28 days following thoracotomy. There was no mortality amongst above treated children. Conclusions: Majority of children with empyema thoracis are manageable with tube thoracostomy, antibiotics, physiotherapy and other supportive treatment. Few of them who fail to above measures need more aggressive management.

  3. Imaging of blunt chest trauma

    International Nuclear Information System (INIS)

    Wicky, S.; Wintermark, M.; Schnyder, P.; Capasso, P.; Denys, A.

    2000-01-01

    In western European countries most blunt chest traumas are associated with motor vehicle and sport-related accidents. In Switzerland, 39 of 10,000 inhabitants were involved and severely injured in road accidents in 1998. Fifty two percent of them suffered from blunt chest trauma. According to the Swiss Federal Office of Statistics, traumas represented in men the fourth major cause of death (4 %) after cardiovascular disease (38 %), cancer (28 %), and respiratory disease (7 %) in 1998. The outcome of chest trauma patients is determined mainly by the severity of the lesions, the prompt appropriate treatment delivered on the scene of the accident, the time needed to transport the patient to a trauma center, and the immediate recognition of the lesions by a trained emergency team. Other determining factors include age as well as coexisting cardiac, pulmonary, and renal diseases. Our purpose was to review the wide spectrum of pathologies related to blunt chest trauma involving the chest wall, pleura, lungs, trachea and bronchi, aorta, aortic arch vessels, and diaphragm. A particular focus on the diagnostic impact of CT is demonstrated. (orig.)

  4. Correlations between quality indexes of chest compression.

    Science.gov (United States)

    Zhang, Feng-Ling; Yan, Li; Huang, Su-Fang; Bai, Xiang-Jun

    2013-01-01

    Cardiopulmonary resuscitation (CPR) is a kind of emergency treatment for cardiopulmonary arrest, and chest compression is the most important and necessary part of CPR. The American Heart Association published the new Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care in 2010 and demanded for better performance of chest compression practice, especially in compression depth and rate. The current study was to explore the relationship of quality indexes of chest compression and to identify the key points in chest compression training and practice. Totally 219 healthcare workers accepted chest compression training by using Laerdal ACLS advanced life support resuscitation model. The quality indexes of chest compression, including compression hands placement, compression rate, compression depth, and chest wall recoil as well as self-reported fatigue time were monitored by the Laerdal Computer Skills and Reporting System. The quality of chest compression was related to the gender of the compressor. The indexes in males, including self-reported fatigue time, the accuracy of compression depth and the compression rate, the accuracy of compression rate, were higher than those in females. However, the accuracy of chest recoil was higher in females than in males. The quality indexes of chest compression were correlated with each other. The self-reported fatigue time was related to all the indexes except the compression rate. It is necessary to offer CPR training courses regularly. In clinical practice, it might be better to change the practitioner before fatigue, especially for females or weak practitioners. In training projects, more attention should be paid to the control of compression rate, in order to delay the fatigue, guarantee enough compression depth and improve the quality of chest compression.

  5. Importance of crevices formed between tubes and tube plate for the operational behaviour of heat exchangers

    International Nuclear Information System (INIS)

    Achten, N.; Herbsleb, G.; Wieling, N.

    1986-01-01

    It must be guaranteed by construction and manufacture of heat exchangers that primary and secondary medium are completely separated from each other. When this requirement is fullfilled, the operational use of heat exchangers can be impaired by corrosion reactions within the crevice formed between tube and tube plate which may result in corrosion damage. The various techniques which are in use to connect tubes and tube plate and which are described in the present report, must be valued with respect to the tightness of the connection as well as to the formation of crevices between tubes and tube plate. Corrosion resistant copperbase alloys and stainless steels are the most important materials which are in use for the construction of heat exchangers. The mechanisms of crevice corrosion with unalloyed and low alloy carbon steels, stainless steels, and mixed connections between tube and tube plate with these materials are described in detail. Crevice corrosion may be caused also by the formation of galvanic cells between materials of differing electrochemical response. Furthermore, the concentration of aggressive media in crevices between tubes and tube plate can lead to corrosion damage of heat exchanger tubes. For the service operation of heat exchangers without any hazard of corrosion damage in crevices between tubes and tube plate, such crevices must be avoided by proper construction and manufacture. As a model for suitable measures to avoid crevices, the manufacture of steam generators for PWR's is described. (orig.) [de

  6. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study

    OpenAIRE

    Hiremath, Mallayya C.; Srivastava, Pooja

    2016-01-01

    Purpose: The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. Materials and Methods: A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presenc...

  7. Influence of chest compression rate guidance on the quality of cardiopulmonary resuscitation performed on manikins.

    Science.gov (United States)

    Jäntti, H; Silfvast, T; Turpeinen, A; Kiviniemi, V; Uusaro, A

    2009-04-01

    The adequate chest compression rate during CPR is associated with improved haemodynamics and primary survival. To explore whether the use of a metronome would affect also chest compression depth beside the rate, we evaluated CPR quality using a metronome in a simulated CPR scenario. Forty-four experienced intensive care unit nurses participated in two-rescuer basic life support given to manikins in 10min scenarios. The target chest compression to ventilation ratio was 30:2 performed with bag and mask ventilation. The rescuer performing the compressions was changed every 2min. CPR was performed first without and then with a metronome that beeped 100 times per minute. The quality of CPR was analysed with manikin software. The effect of rescuer fatigue on CPR quality was analysed separately. The mean compression rate between ventilation pauses was 137+/-18compressions per minute (cpm) without and 98+/-2cpm with metronome guidance (pmetronome (pmetronome guidance (p=0.09). The total number of chest compressions performed was 1022 without metronome guidance, 42% at the correct depth; and 780 with metronome guidance, 61% at the correct depth (p=0.09 for difference for percentage of compression with correct depth). Metronome guidance corrected chest compression rates for each compression cycle to within guideline recommendations, but did not affect chest compression quality or rescuer fatigue.

  8. The forgotten view: Chest X-ray - Lateral view

    Directory of Open Access Journals (Sweden)

    Abraham M. Ittyachen

    2017-01-01

    Full Text Available With CT (computed tomography chest gaining more importance as a diagnostic tool, chest X-ray especially the lateral view is taken less commonly nowadays. Besides CT chest is also proven to be superior to chest X-ray in patients with major blunt trauma. We are presenting a 68-year old male who was partially treated from outside for a left sided pneumonia. He came to our hospital because of persisting chest pain. Chest X-ray, frontal view (postero-anterior was almost normal except for a mild opacity in the left lower zone. CT scan of the chest revealed a fluid collection posteriorly enclosed within enhancing pleura. Chest X-ray, left lateral view showed a corresponding posterior pleural based opacity. We are presenting this case to highlight the importance of the lateral view of the chest X-ray. In selected cases there is still a role for the lateral view. With the three dimensional visualization provided by the CT, the lateral view of the chest may be easier to understand. Consequent to the initial diagnosis by CT further follow up can be done with the chest X-ray. In a limited way this mitigates unnecessary expenditure and more importantly prevents the patient from exposure to harmful radiation in the form of repeated CT.

  9. Large pneumothorax in blunt chest trauma: Is a chest drain always necessary in stable patients? A case report

    OpenAIRE

    Idris, Baig M.; Hefny, Ashraf F.

    2016-01-01

    Introduction: Pneumothorax is the most common potentially life-threatening blunt chest injury. The management of pneumothorax depends upon the etiology, its size and hemodynamic stability of the patient. Most clinicians agree that chest drainage is essential for the management of traumatic large pneumothorax. Herein, we present a case of large pneumothorax in blunt chest trauma patient that resolved spontaneously without a chest drain. Presentation of case: A 63- year- old man presented...

  10. The use of a water seal to manage air leaks after a pulmonary lobectomy: a retrospective study.

    Science.gov (United States)

    Okamoto, Junichi; Okamoto, Tatsuro; Fukuyama, Yasuro; Ushijima, Chie; Yamaguchi, Masafumi; Ichinose, Yukito

    2006-08-01

    The methods for managing chest drainage tubes during the postoperative period differ among thoracic surgeons and, as a result, the optimal method remains controversial. We reviewed 170 consecutive patients undergoing a pulmonary lobectomy for either primary lung cancer or metastatic lung cancer from January 1998 to December 2002. After the operation, the chest drainage tube was placed on a suction pump with a negative pressure of -10 cmH(2)O in 120 patients before 2001, while such drainage tubes were kept on water seal in 47 cases mainly since 2001. Regarding the preoperative and postoperative variables, postoperative air leak as well as the video-assisted thoracic surgery (VATS) procedure were more frequently observed in the water seal group than in the suction group (p=0.01580, pleak seemed to be similar between the two methods. These observations suggest that applying chest tubes on water seal seems to be an effective method for preventing postoperative air leak in clinical practice. However, a prospective randomized trial using a larger series of patients is warranted for this subject.

  11. Treatment Options by Stage (Ovarian Epithelial, Fallopian Tube, and Primary Peritoneal Cancer)

    Science.gov (United States)

    ... diagnosed, tests are done to find out if cancer cells have spread within the ovaries or to other parts of the body. The ... single ovary or fallopian tube. In stage IB, cancer is found inside both ovaries or fallopian tubes. In stage IC, cancer is ...

  12. Noncardiac chest pain: diagnosis and management.

    Science.gov (United States)

    Yamasaki, Takahisa; Fass, Ronnie

    2017-07-01

    Noncardiac chest pain (NCCP) has been defined as recurrent chest pain that is indistinguishable from ischemic heart pain after excluding a cardiac cause. NCCP is a common and highly challenging clinical problem in Gastrointestinal practice that requires targeted diagnostic assessment to identify the underlying cause of the symptoms. Treatment is tailored according to the cause of NCCP: gastroesophageal reflux disease (GERD), esophageal dysmotility or functional chest pain. The purpose of this review is to discuss the current diagnosis and treatment of NCCP. Utilization of new diagnostic techniques such as pH-impedance and high-resolution esophageal manometry, and the introduction of a new definition for functional chest pain have helped to better diagnose the underlying mechanisms of NCCP. A better therapeutic approach toward GERD-related NCCP, the introduction of new interventions for symptoms due to esophageal spastic motor disorders and the expansion of the neuromodulator armamentarium for functional chest pain have changed the treatment landscape of NCCP. GERD is the most common esophageal cause of NCCP, followed by functional chest pain and esophageal dysmotility. The proton pump inhibitor test, upper endoscopy, wireless pH capsule and pH-impedance are used to identify GERD-induced NCCP. High-resolution esophageal manometry is the main tool to identify esophageal motor disorder in non-GERD-related NCCP. Negative diagnostic assessment suggests functional chest pain. Potent antireflux treatment is offered to patients with GERD-related NCCP; medical, endoscopic or surgical interventions are considered in esophageal dysmotility; and neuromodulators are prescribed for functional chest pain. Assessment and treatment of psychological comorbidity should be considered in all NCCP patients.

  13. Coronary artery dissection following chest trauma

    Directory of Open Access Journals (Sweden)

    Manoj K Agarwala

    2016-01-01

    Full Text Available Chest trauma has a high rate of mortality. Coronary dissection causing myocardial infarction (MI following blunt chest trauma is rare. We describe the case of an anterior MI following blunt chest trauma. A 39-year-old male was received in our hospital following a motorcycle accident. The patient was asymptomatic before the accident. The patient underwent craniotomy for evacuation of hematoma. He developed severe chest pain and an electrocardiogram (ECG revealed anterior ST segment elevation following surgery. Acute coronary event was medically managed; subsequently, coronary angiogram was performed that showed dissection in the left anterior coronary artery, which was stented.

  14. Initial quality performance results using a phantom to simulate chest computed radiography

    Directory of Open Access Journals (Sweden)

    Muhogora Wilbroad

    2011-01-01

    Full Text Available The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR. The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA plates as well as Styrofoam materials. Depending on combinations, the literature suggests that these materials can simulate the attenuation and scattering characteristics of lung, heart, and mediastinum. The lung, heart, and mediastinum regions were simulated by 10 mm x 10 mm x 0.5 mm, 10 mm x 10 mm x 0.5 mm and 10 mm x 10 mm x 1 mm copper plates, respectively. A test object of 100 mm x 100 mm and 0.2 mm thick copper was positioned to each region for CNR measurements. The phantom was exposed to x-rays generated by different tube potentials that covered settings in clinical use: 110-120 kVp (HVL=4.26-4.66 mm Al at a source image distance (SID of 180 cm. An approach similar to the recommended method in digital mammography was applied to determine the CNR values of phantom images produced by a Kodak CR 850A system with post-processing turned off. Subjective contrast-detail studies were also carried out by using images of Leeds TOR CDR test object acquired under similar exposure conditions as during CNR measurements. For clinical kVp conditions relevant to chest radiography, the CNR was highest over 90-100 kVp range. The CNR data correlated with the results of contrast detail observations. The values of clinical tube potentials at which CNR is the highest are regarded to be optimal kVp settings. The simplicity in phantom construction can offer easy implementation of related quality control program.

  15. Early appearance of SARS on chest CT scan

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Feng Suchen; Xia Guoguang; Zhao Tao; Gu Xiang; Qu Hui

    2003-01-01

    Objective: To evaluate the early appearance of SARS on chest CT scan and its role in the early diagnosis. Methods: Forty cases of SARS in keeping with the criteria of the Ministry of Health had chest CT scans within 7 days of onset of symptoms, and CR chest X-ray films were available as well. These chest X-rays and CT images were retrospectively reviewed to determine if there were any abnormalities on the images. The lesions on the chest CT images were then further analyzed in terms of the number, location, size, and density. Results: Positive abnormalities on chest CT scans were revealed in all 40 SARS cases. Positive findings on CR chest films were showed in only 25 cases, equivocal in 6, and normal in 9 cases. The main abnormalities seen on CT and X-rays were pulmonary infiltrations varied markedly in severity. 70 % cases had 1 or 2 lesions on chest CT scan, 30 % cases had 3 or more lesions. The lesions seen on chest CT scan tended to be ground-glass opacification, sometimes with consolidation which was very faint and inhomogeneous, easily missed on chest X-rays. Typically the lesions were located in the periphery of the lung, or both central and peripheral lung, but very rare in a pure central location. They were commonly in the shape of patch or ball. Conclusions: Chest CT scan is much more sensitive in detecting the lesions of the lung in SARS. The early appearance of SARS on chest CT scan is characteristic but non-specific, indicating that chest CT scan plays a very important role in the early diagnosis and differential diagnosis of SARS

  16. Treatment of air leak in polytrauma patients with blunt chest injury.

    Science.gov (United States)

    Halat, Gabriel; Negrin, Lukas L; Chrysou, Konstantina; Hoksch, Beatrix; Schmid, Ralph A; Kocher, Gregor J

    2017-09-01

    Precise diagnostics and an adequate therapeutic approach are mandatory in the treatment of air leak in polytrauma patients with blunt chest trauma. The aim of this study was to evaluate the incidence, characteristics, and management of air leak following this injury pattern. Data from 110 polytrauma patients was collected retrospectively. Fifty-four patients received initial treatment by chest tube placement for pneumothorax. These patients were classified into two groups, one with severe air leak and one with minor air leak. An evaluation of injury pattern, chest wall injuries in particular, duration of air leak, reason for drainage maintenance in place, hospital length of stay, ICU stay, ventilator duration, type of treatment, and the delay to surgical intervention was performed. Whereas 4 patients showed severe air leak and were subsequently scheduled for timely surgical intervention, the remaining 50 patients only showed minor air leak. Only 7 patients with minor air leak suffered from prolonged air leak (>5days), which spontaneously resolved in all of them after a mean duration of 7.7days (range 6-12days). Absence of a prolonged air leak resulted in a shorter length of stay and a shorter duration of mechanical ventilation, although no statistical significance was observed. Early spontaneous cessation of most minor air leaks as well as early surgical intervention for severe air leak lead to very satisfactory patient outcomes with a relatively short hospital stay in our patients. We therefore advocate early surgery for lacerations of the pulmonary parenchyma resulting in severe air leak, whereas minor air leaks can usually be treated conservatively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Steam generator tube rupture effects on a LOCA

    International Nuclear Information System (INIS)

    LaChance, J.L.

    1979-01-01

    A problem currently experienced in commercial operating pressurized water reactors (PWR) in the United States is the degradation of steam generator tubes. Safety questions have arisen concerning the effect of these degraded tubes rupturing during a postulated loss-of-coolant accident (LOCA). To determine the effect of a small number of tube ruptures on the behavior of a large PWR during a postulated LOCA, a series of computer simulations was performed. The primary concern of the study was to determine whether a small number (10 or less of steam generator tubes rupturing at the beginning surface temperatures. Additional reflood analyses were performed to determine the system behavior when from 10 to 60 tubes rupture at the beginning of core reflood. The FLOOD4 code was selected as being the most applicable code for use in this study after an extensive analysis of the capabilities of existing codes to perform simulations of a LOCA with concurrent steam generator tube ruptures. The results of the study indicate that the rupturing of 10 or less steam generator tubes in any of the steam generators during a 200% cold leg break will not result in a significant increase in the peak cladding temperature. However, because of the vaporization of the steam generator secondary water in the primary side of the steam generator, a significant increase in the core pressure occurs which retards the reflooding process

  18. The measurement of organic radiation dose of multi-slice CT scanning by using the Chinese anthropomorphic chest phantom

    International Nuclear Information System (INIS)

    Peng Gang; Zeng Yongming; Luo Tianyou; Zhao Feng; Zhang Zhiwei; Yu Renqiang; Peng Shengkun

    2011-01-01

    Objective: Using the Chinese anthropomorphic chest phantom to measure the absorbed dose of various tissues and organs under different noise index, and to assess the radiation dose of MSCT chest scanning with the effective dose (ED). Methods: The equivalence of the Chinese anthropomorphic chest phantom (CDP-1 C) and the adult chest on CT sectional anatomy and X-ray attenuation was demonstrated. The absorbed doses of various tissues and organs under different noise index were measured by laying thermoluminescent dosimeters (TLD) inside the phantom, and the corresponding dose-length products (DLP) were recorded. Both of them were later converted into ED and comparison was conducted to analyze the dose levels of chest CT scanning with automatic tube current modulation (ATCM) under different noise index. Student t-test was applied using SPSS 12.0 statistical software. Results: The Phantom was similar to the human body on CT sectional anatomy. The average CT value of phantom are - 788.04 HU in lung, 45.64 HU in heart, 65.84 HU in liver, 254.32 HU in spine and the deviations are 0.10%, 3.04%, 4.49% and 4.36% respectively compared to humans. The difference of average CT value of liver was statistically significant (t=-8.705, P 0.05). As the noise index increased from 8.5 to 22.5, the DLP decreased from 393.57 mGy · cm to 78.75 mGy · cm and the organs dose declined. For example, the average absorbed dose decreased from 22.38 mGy to 3.66 mGy in lung. Compared to ED calculating by absorbed dose, the ED calculating by DLP was lower. The ED values of the two methods were 6.69 mSv and 8.77 mSv when the noise index was set at 8.5. Conclusions: Application of the Chinese anthropomorphic chest phantom to carry out CT dose assessment is more accurate. The noise index should be set more than 8.5 during the chest CT scanning based on ATCM technique. (authors)

  19. Improving screen-film chest radiography

    International Nuclear Information System (INIS)

    Shaikh, N.; Baker, R.A.

    1996-01-01

    Traditionally symmetric screens and double emulsion symmetric films with medium to wide latitutde are used for radiography of the chest. Beacuse of mismatch of transmitted exposure through the chest with limited latitude of the film, most of the dense areas of the chest are underexposed. Kodak's recent innovation of a unique asymmetry screen-film system (InSight) alleviates this problem. Our phantom measurement indicates that the InSight system offers wider recording range, and the flexible grid permits more positional latitude than conventional grids. Our five-year extensive clinical experience indicates that dense anatomic structures, such as mediastinum, retrocardiac and subdiaphragmatic, are more visible in the InSight system than in the conventional symmetric system. Similarly, a substantial improvement in image quality in portable chest imaging is realized by use of flexible grids because of scatter rejection and invisible grid lines. (author)

  20. Randomized study of percutaneous endoscopic gastrostomy versus nasogastric tubes for enteral feeding in head and neck cancer patients treated with (chemo)radiation

    International Nuclear Information System (INIS)

    Corry, J.; Poon, W.; McPhee, N.; Milner, A. D.; Cruickshank, D.; Rischin, D.; Peters, L. J.

    2008-01-01

    Full text: Percutaneous endoscopic gastrostomy (PEG) tubes have largely replaced nasogastric tubes (NGT) for nutritional support of patients with head and neck cancer undergoing curative (chemo)radiotherapy without any good scientific basis. A randomized trial was conducted to compare PEG tubes and NGT in terms of nutritional outcomes, complications, patient satisfaction and cost. The study was closed early because of poor accrual, predominantly due to patients' reluctance to be randomized. There were 33 patients eligible for analysis. Nutritional support with both tubes was good. There were no significant differences in overall complication rates, chest infection rates or in patients' assessment of their overall quality of life. The cost of a PEG tube was 10 times that of an NGT. The duration of use of PEG tubes was significantly longer, a median 139 days compared with a median 66 days for NGT. We found no evidence to support the routine use of PEG tubes over NGT in this patient group

  1. Regionally adaptive histogram equalization of the chest

    International Nuclear Information System (INIS)

    Sherrier, R.H.; Johnson, G.A.

    1986-01-01

    Advances in digital chest radiography have resulted in the acquisition of high-quality digital images of the human chest. With these advances, there arises a genuine need for image processing algorithms, specific to chest images. The author has implemented the technique of histogram equalization, noting the problems encountered when it is adapted to chest images. These problems have been successfully solved with a regionally adaptive histogram equalization method. Histograms are calculated locally and then modified according to both the mean pixel value of a given region and certain characteristics of the cumulative distribution function. The method allows certain regions of the chest radiograph to be enhanced differentially

  2. Radiology in chest trauma

    International Nuclear Information System (INIS)

    Wenz, W.; Kloehn, I.; Wolfart, W.; Freiburg Univ.

    1979-01-01

    In chest trauma, a routine chest film, preferably in the lateral as well as the frontal projection, is the basic part of the work-up. Occasionally valuable additional methods are fluoroscopy, tomography, bronchography, contrast studies of the GI Tract and angiography and angiocardiography. In 679 chest trauma patients, traffic accidents and falls were the main reason for the trauma. There were 248 fractures; then - in order of frequency - hemopneumothorax (76), lung contusion (58), subcutaneous emphysema (33) cardiac (16) and vascular trauma (12) and damage to other organs. While 20-30% mistakes are made in diagnosing rib fractures in acute trauma, there is high accuracy in the diagnosis of the other injuries. Many cases are shown to demonstrate the value of diagnostic radiology. (orig.) [de

  3. The impact of chest compression rates on quality of chest compressions - a manikin study.

    Science.gov (United States)

    Field, Richard A; Soar, Jasmeet; Davies, Robin P; Akhtar, Naheed; Perkins, Gavin D

    2012-03-01

    Chest compressions are often performed at a variable rate during cardiopulmonary resuscitation (CPR). The effect of compression rate on other chest compression quality variables (compression depth, duty-cycle, leaning, performance decay over time) is unknown. This randomised controlled cross-over manikin study examined the effect of different compression rates on the other chest compression quality variables. Twenty healthcare professionals performed 2 min of continuous compressions on an instrumented manikin at rates of 80, 100, 120, 140 and 160 min(-1) in a random order. An electronic metronome was used to guide compression rate. Compression data were analysed by repeated measures ANOVA and are presented as mean (SD). Non-parametric data was analysed by Friedman test. At faster compression rates there were significant improvements in the number of compressions delivered (160(2) at 80 min(-1) vs. 312(13) compressions at 160 min(-1), P<0.001); and compression duty-cycle (43(6)% at 80 min(-1) vs. 50(7)% at 160 min(-1), P<0.001). This was at the cost of a significant reduction in compression depth (39.5(10)mm at 80 min(-1) vs. 34.5(11)mm at 160 min(-1), P<0.001); and earlier decay in compression quality (median decay point 120 s at 80 min(-1) vs. 40s at 160 min(-1), P<0.001). Additionally not all participants achieved the target rate (100% at 80 min(-1) vs. 70% at 160 min(-1)). Rates above 120 min(-1) had the greatest impact on reducing chest compression quality. For Guidelines 2005 trained rescuers, a chest compression rate of 100-120 min(-1) for 2 min is feasible whilst maintaining adequate chest compression quality in terms of depth, duty-cycle, leaning, and decay in compression performance. Further studies are needed to assess the impact of the Guidelines 2010 recommendation for deeper and faster chest compressions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?

    International Nuclear Information System (INIS)

    Kibriya, N.; Wilbraham, L.; Mullan, D.; Puro, P.; Vasileuskaya, S.; Edwards, D.W.; Laasch, H.-U.

    2013-01-01

    Aim: To assess the insertion procedure and performance of disc-retained gastrostomy tubes, recording complications and accidental displacements by prospective audit, and to determine whether primary placement of the tube off-licence was feasible. Materials and methods: Disc-retained 12 F single-lumen Monarch gastrostomy tubes (Enteral UK, Selby, UK) were inserted by three gastrointestinal interventional radiologists in a supra-regional cancer centre. The 12 F tubes required a 20 F peel-away sheath with four-point gastropexy fixation and were placed under conscious sedation, using electrocardiogram (EEG) bispectral index monitoring. Follow-up was performed in an in-house gastrostomy drop-in clinic at 1 week and 1 month, supplemented with weekly telephone follow-up. Patients also had open access to the gastrostomy drop-in clinic for immediate advice and complication management. Results: Eighteen patients underwent primary insertion of a Monarch gastrostomy tube over 5 months. A total of 6/18 (33%) tubes displaced; 4/18 (22%) completely, 2/18 (11%) occult into the peritoneum. Four of 18 (22%) patients developed infection at the stoma site. Due to the unexpectedly poor performance of the tube, the study was terminated early. Conclusion: Initial experience with the Monarch disc-retained gastrostomy tube demonstrates it unsuitable for primary placement with current protocols. In view of the potentially serious complications, the Medicines and Healthcare Products Regulatory Agency (MHRA) has been informed. A request has been made to the distributer to reassess the tube design and/or review the procedure promoted for primary placement

  5. Use of chest sonography in acute-care radiology☆

    Science.gov (United States)

    De Luca, C.; Valentino, M.; Rimondi, M.R.; Branchini, M.; Baleni, M. Casadio; Barozzi, L.

    2008-01-01

    Diagnosis of acute lung disease is a daily challenge for radiologists working in acute-care areas. It is generally based on the results of chest radiography performed under technically unfavorable conditions. Computed tomography (CT) is undoubtedly more accurate in these cases, but it cannot always be performed on critically ill patients who need continuous care. The use of thoracic ultrasonography (US) has recently been proposed for the study of acute lung disease. It can be carried out rapidly at the bedside and does not require any particularly sophisticated equipment. This report analyzes our experience with chest sonography as a supplement to chest radiography in an Emergency Radiology Unit. We performed chest sonography – as an adjunct to chest radiography – on 168 patients with acute chest pathology. Static and dynamic US signs were analyzed in light of radiographic findings and, when possible, CT. The use of chest US improved the authors' ability to provide confident diagnoses of acute disease of the chest and lungs. PMID:23397048

  6. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    Energy Technology Data Exchange (ETDEWEB)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung [Samsung Medical Center, Seoul (Korea, Republic of); Chung, Seung Eun [Sangkye Paek Hospital, Seoul (Korea, Republic of)

    1996-12-15

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  7. Unilateral Hemithorax Opacification on Chest Radiograph : Comparison of Diagnostic Accuracy of Chest Ultrasonography with CT

    International Nuclear Information System (INIS)

    Namkung, Sook; Lee, Kyung Soo; Kwon, O Jung; Chung, Seung Eun

    1996-01-01

    To compare the diagnostic accuracy of chest ultrasonography (US) with computed tomography (CT) inpatients with opacification more than one third of unilateral hemithorax on chest radiograph (CXR). Chest US and CT scans from 41 consecutive patients with opacification more than one third of unilateral hemithorax on CXR were prospectively evaluated by two independent radiologists. Each radiologist recorded 1) the nature of pleural effusion (transudate vs. exudate), 2) presence or absence of pulmonary lesion, 3) the characteristic of pulmonary lesion (consolidation or atelectasis and tumor), and 4) presence of solid pleural tumor. The diagnostic accuracy of chest US was compared with CT scan in patients with pleural, pulmonary or other disease. In 32 patients with pleural effusion, differentiation between transudate and exudate was feasible in 27 (84%) patients with US and 26 (81%) patients with CT. In 32 patients with pulmonary and other pleural diseases, sensitivity, specificity and accuracy of US in lesion detection were 86%, 75% and 83% respectively when CT was regarded as a diagnostic gold standard. The diagnostic accuracy of chest US is comparable to CT in patients with hemithorax opacification on CXR

  8. Acetyl-L-Carnitine Hydrochloride in Preventing Peripheral Neuropathy in Patients With Recurrent Ovarian Epithelial Cancer, Primary Peritoneal Cavity Cancer, or Fallopian Tube Cancer Undergoing Chemotherapy

    Science.gov (United States)

    2014-12-29

    Fatigue; Malignant Ovarian Mixed Epithelial Tumor; Neuropathy; Neurotoxicity Syndrome; Ovarian Brenner Tumor; Ovarian Clear Cell Cystadenocarcinoma; Ovarian Endometrioid Adenocarcinoma; Ovarian Mucinous Cystadenocarcinoma; Ovarian Serous Cystadenocarcinoma; Pain; Recurrent Fallopian Tube Carcinoma; Recurrent Ovarian Carcinoma; Recurrent Primary Peritoneal Carcinoma

  9. Effectiveness of feedback with a smartwatch for high-quality chest compressions during adult cardiac arrest: A randomized controlled simulation study.

    Science.gov (United States)

    Ahn, Chiwon; Lee, Juncheol; Oh, Jaehoon; Song, Yeongtak; Chee, Youngjoon; Lim, Tae Ho; Kang, Hyunggoo; Shin, Hyungoo

    2017-01-01

    Previous studies have demonstrated the potential for using smartwatches with a built-in accelerometer as feedback devices for high-quality chest compression during cardiopulmonary resuscitation. However, to the best of our knowledge, no previous study has reported the effects of this feedback on chest compressions in action. A randomized, parallel controlled study of 40 senior medical students was conducted to examine the effect of chest compression feedback via a smartwatch during cardiopulmonary resuscitation of manikins. A feedback application was developed for the smartwatch, in which visual feedback was provided for chest compression depth and rate. Vibrations from smartwatch were used to indicate the chest compression rate. The participants were randomly allocated to the intervention and control groups, and they performed chest compressions on manikins for 2 min continuously with or without feedback, respectively. The proportion of accurate chest compression depth (≥5 cm and ≤6 cm) was assessed as the primary outcome, and the chest compression depth, chest compression rate, and the proportion of complete chest decompression (≤1 cm of residual leaning) were recorded as secondary outcomes. The proportion of accurate chest compression depth in the intervention group was significantly higher than that in the control group (64.6±7.8% versus 43.1±28.3%; p = 0.02). The mean compression depth and rate and the proportion of complete chest decompressions did not differ significantly between the two groups (all p>0.05). Cardiopulmonary resuscitation-related feedback via a smartwatch could provide assistance with respect to the ideal range of chest compression depth, and this can easily be applied to patients with out-of-hospital arrest by rescuers who wear smartwatches.

  10. The Sealed Tube Neutron Generator

    International Nuclear Information System (INIS)

    Tunnell, L.N.; Beyerle, A.; Durkee, R.; Headley, G.; Hurley, P.

    1992-01-01

    A Sealed Tube Neutron Generator (STNG) has been designed and tested at Special Technologies Laboratories (STL) in Santa Barbara, California. Unlike similar tubes that have been used for years in other applications, e.g., by the oil well logging industry, the present device was designed primarily to be part of the Associated Particle Imaging (API) system. Consequently, the size and quality of the neutron spot produced by the STNG is of primary importance. Results from initial measurements indicate that performance goals are satisfied

  11. Pressure tube reactors

    International Nuclear Information System (INIS)

    Natori, Hisahide.

    1981-01-01

    Purpose: To improve the electrical power generation efficiency in a pressure tube reactor in which coolants and moderators are separated by feedwater heating with heat generated in heavy water and by decreasing the amount of steams to be extracted from the turbine. Constitution: A heat exchanger and a heavy water cooler are additionally provided to a conventional pressure tube reactor. The heat exchanger is disposed at the pre-stage of a low pressure feedwater heater series. High temperature heavy water heated in the core is passed through the primary side of the exchanger, while feedwater is passed through the secondary side. The cooler is disposed on the downstream of the heat exchanger in the flowing direction of the heavy water, in which heavy water from the heat exchanger is passed through the primary side and the auxiliary equipment cooling water is sent to the secondary side thereof. Accordingly, since extraction of heating steams is no more necessary, the steam can be used for the rotation of the turbine, and the electrical power generation efficiency can be improved. (Seki, T.)

  12. CT-Guided, Ethanol Sympatholysis for Primary Axillary–Palmar Hyperhidrosis

    Energy Technology Data Exchange (ETDEWEB)

    Tsitskari, Maria, E-mail: mariadote@hotmail.com [American Medical Center, Vascular & Interventional Radiology (Cyprus); Friehs, Gerhard, E-mail: gerhardf@amc.com.cy; Zerris, Vassilis, E-mail: vassilisz@amc.com.cy [American Medical Center, Neurosurgery (Cyprus); Georgiades, Christos, E-mail: g-christos@hotmail.com [Johns Hopkins Hospital, Vascular & Interventional Radiology (United States)

    2016-12-15

    PurposePrimary hyperhidrosis is an excessive sweating due to an overactive sympathetic system. Our objective was to test the feasibility and provide early data on the safety/efficacy of CT-guided sympatholysis, for primary hyperhidrosis.Materials and MethodsNine consecutive patients with axillary–palmar hyperhidrosis were treated between 2013 and 2015. CT-guided sympathetic block was performed in the outpatients at T-2, T-3, and T-4, bilaterally using alcohol under local anesthesia. Immediate postprocedure CT was obtained to assess the complications as per Common Terminology Criteria for Adverse Events, version 4. Technical success and clinical success were recorded. Primary and secondary efficacy were assessed by phone and clinical visits; mean follow-up was 12 months (6–26 months). Descriptive statistics was used to report the outcomes.ResultsOne procedure was aborted due to eyelid ptosis after lidocaine injection. All other eight patients (5:3, F:M) (median age 32) had immediate cessation of sweating. Two major complications (pneumothorax, one requiring a chest tube) occurred. Two patients recurred with unilateral and one with bilateral symptoms. One of the unilateral recurrence and the bilateral recurrence patients was retreated successfully. Median follow-up was 1 year. No cases of Horner’s or compensatory hyperhidrosis were observed.ConclusionsCT-guided EtOH sympatholysis for axillary/palmar primary hyperhidrosis is feasible. Technical failure rate was 11 %. Primary and secondary efficacy are 75 and 94 %, respectively, to a median follow-up of 1 year. Risk profile appears favorable. Despite a small sample size, results confirm feasibility and encourage a larger study.

  13. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    International Nuclear Information System (INIS)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H.

    1998-01-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.)

  14. Significance of various pulmonary and extrapulmonary abnormalities on HRCT of the chest in scleroderma lung

    International Nuclear Information System (INIS)

    Pandey, Anoop Kumar; Wilcox, Pearce; O’ Brien, Julie; Ellis, Jennifer; Brown, Jacquie; Leipsic, Jonathon

    2013-01-01

    Patients with systemic sclerosis (SSc) are routinely investigated with high-resolution computed tomography (HRCT) chest for early detection and accurate characterization of complicating interstitial lung diseases. Though the primary aim of HRCT is to delineate the burden of pulmonary involvement and to characterize the nature of fibrosis to potentially help guide management, it provides an opportunity to evaluate extrapulmonary manifestations, particularly the dilated pulmonary artery, esophageal dilatation, and pericardial abnormalities which have their own clinical significance. The aim of this article is to discuss the significance of various pulmonary and extrapulmonary abnormalities that may be identified on HRCT chest of SSc patients

  15. Computed tomography of chest wall abscess

    International Nuclear Information System (INIS)

    Ikezoe, Junpei; Morimoto, Shizuo; Akira, Masanori

    1986-01-01

    Inflammatory lesions of the chest wall become less common because of the improvement of antibiotics and chemotherapeutic agents. Over a 5-year period, 7 patients with chest wall inflammatory diseases underwent chest computed tomography. These were 2 tuberculous pericostal abscesses, 2 empyema necessitatis, 1 spinal caries, and 2 bacterial chest wall abscesses (unknown organisms). Computed tomography (CT) helped in demonstrating the density, border, site, and extent of the lesions. CT images also demonstrated the accompaning abnormalities which included bone changes, pleural calcification, or old tuberculous changes of the lung. CT was very effective to demonstrate the communicating portions from the inside of the bony thorax to the outside of the bony thorax in 2 empyema necessitatis. (author)

  16. Ultrasonographic examination in chest disease

    Energy Technology Data Exchange (ETDEWEB)

    Choe, K.O.; Lee, J.D.; Yoo, H.S. [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1983-12-15

    Ultrasonographic examination is not widely applied to chest disease, but is may give useful information when the acoustic window for a lesion exist. We did perform ultrasound examination in 68 cases of chest disease. 1. The cases of pleural diseases was predominant; pleural effusion 35 cases, pleural metastatic tumor 2 case, mesothelioma 2 cases and fibrous thickening 1 case, total 40 cases. It was useful to differentiate pleural effusion and fibrous thickening or parenchymal lesion simulating pleural disease, to localize the optimal aspiration site for a loculated empyema, to detect pleural bumorhidden by effusion such as metastatic tumor or mesothelioma. 2. 15 cases of parenchymal lesion and 2 cases of extra pleural mass was examined. The echo pattern of consolidation and atelectasis shows typical multiple tubular streaks within the echogenic area. The echogenicity of the peripheral mass due to primary bronchogenic carcinoma, parenchymal or extrapleural metastatic tumor and granuloma were compared. 3. In the cases of pleural or parenchymal cystic lesions, such as loculated empyema or lung abscess, because of strong reverberation artifact from posterior border of the lesion, the prediction of cystic and solid lesion is sometimes difficult. 4. In 7 cases of mediastinal lesion, cystic lesion show free echo and posterior enhancement. In contrast, solid or fat component show characteristic echo pattern. 5. In the cases of juxta diaphragmatic lesion, sonogram can confirm the underlying intraabdominal pathology, in this case subphrenic abscess

  17. Ultrasonographic examination in chest disease

    International Nuclear Information System (INIS)

    Choe, K.O.; Lee, J.D.; Yoo, H.S.

    1983-01-01

    Ultrasonographic examination is not widely applied to chest disease, but is may give useful information when the acoustic window for a lesion exist. We did perform ultrasound examination in 68 cases of chest disease. 1. The cases of pleural diseases was predominant; pleural effusion 35 cases, pleural metastatic tumor 2 case, mesothelioma 2 cases and fibrous thickening 1 case, total 40 cases. It was useful to differentiate pleural effusion and fibrous thickening or parenchymal lesion simulating pleural disease, to localize the optimal aspiration site for a loculated empyema, to detect pleural bumorhidden by effusion such as metastatic tumor or mesothelioma. 2. 15 cases of parenchymal lesion and 2 cases of extra pleural mass was examined. The echo pattern of consolidation and atelectasis shows typical multiple tubular streaks within the echogenic area. The echogenicity of the peripheral mass due to primary bronchogenic carcinoma, parenchymal or extrapleural metastatic tumor and granuloma were compared. 3. In the cases of pleural or parenchymal cystic lesions, such as loculated empyema or lung abscess, because of strong reverberation artifact from posterior border of the lesion, the prediction of cystic and solid lesion is sometimes difficult. 4. In 7 cases of mediastinal lesion, cystic lesion show free echo and posterior enhancement. In contrast, solid or fat component show characteristic echo pattern. 5. In the cases of juxta diaphragmatic lesion, sonogram can confirm the underlying intraabdominal pathology, in this case subphrenic abscess

  18. 46 CFR 196.37-47 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Portable magazine chests. 196.37-47 Section 196.37-47... Markings for Fire and Emergency Equipment, etc. § 196.37-47 Portable magazine chests. (a) Portable magazine chests shall be marked in letters at least 3 inches high: PORTABLE MAGAZINE CHEST — FLAMMABLE — KEEP...

  19. Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Becker, J; Hoeschen, C

    2012-01-01

    A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI vol for an eight-week-old baby and seven- and eight-year-old children have been computed accounting for TCM. The relative difference in organ dose conversion coefficients with and without TCM is for many organs and examinations less than 10%, but can in some cases amount up to 30%, e.g., for the thyroid in the chest CT of the seven-year-old child. Overall, the impact of TCM on the conversion coefficients increases with increasing age. Besides TCM, also the effect of collimation and tube voltage on organ dose conversion coefficients has been investigated. It could be shown that the normalization to CTDI vol leads to conversion coefficients that can in most cases be considered to be independent of collimation and tube voltage. (paper)

  20. Ovarian, Fallopian Tube, and Primary Peritoneal Cancer—Patient Version

    Science.gov (United States)

    Ovarian epithelial cancer is the most common type of ovarian cancer. Cancer can also form at the end of the fallopian tube near the ovary or the peritoneum and spread to the ovary. Start here to find information on ovarian cancer treatment, causes and prevention, screening, research, and statistics.

  1. Apparatus for the in-situ inspection of tubes while submerged in a liquid

    International Nuclear Information System (INIS)

    Abell, G.E.; Plavsity, L.; Sattler, F.J.

    1981-01-01

    Before inspecting the tubes in a nuclear steam generator it has previously been necessary to drain the tubes of primary coolant. This invention provides an apparatus which makes it possible to inspect steam generator tubes which are partially filled with primary coolant. An eddy current sensor and its cable pass through a conduit into which a drying medium such as compressed air is introduced, removing coolant adhering to the surface of the cable. (LL)

  2. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    Science.gov (United States)

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients 18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  3. 46 CFR 108.651 - Portable magazine chests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Portable magazine chests. 108.651 Section 108.651... AND EQUIPMENT Equipment Markings and Instructions § 108.651 Portable magazine chests. Each portable magazine chest must be marked: “PORTABLE MAGAZINE CHEST—FLAMMABLE—KEEP LIGHTS AND FIRE AWAY” in letters at...

  4. Findings chest radiograph and CT in mediastinitis: effcacy of CT in patients with delayed diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Son, Eun Ju; Hong, Yong Kook; Choe, Kyu Ok [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To analyse the causes the radiologic findings in patients with mediastinitis and to evaluate the efficacy of chest CT scanning in patients with delayed diagnosis. Seventeen patients with histopathologically(n=15) or clinically diagnosed(n=2) mediastinitis were involved in this study. Eleven of the former group underwent surgery, and in four, tube drainage was performed. All underwent chest radiography and CT scanning, and in seven patients, the causes of delayed diagnosis were analysed. The most common cause of mediastinitis was esophageal rupture(n=11). Others were extension from neck abscess to the mediastinum(n=3), complications after a Benthall procedure(n=1), tuberculous lymphadenitis(n=1) and mycotic aneurysm(n=1). Patients with esophageal rupture suffered from underlying diseases such as esophageal cancer(n=2), iatrogenic esophageal rupture(n=2), Boerhaave's syndrome(n=2), and esophagitis(n=1). In patients with neck abscess (n=3), each was secondary to infected cystic hygroma, Ludwig angina, or deep neck infection, respectively. On chest CT, patients with esophageal rupture(n=11) had an abscess in the posterior mediastinum ; nine abscesses extended to the cervical area along the retropharyngeal space, and the patient with Ludwig angina had an abscess involving all compartments of the mediastinum. Among the total of 17 patients, diagnostic delays were found in seven, while five had spontaneous esophageal ruptures and two suffered complications after a Benthall procedure and Tbc lymphadenitis, respectively. The causes of diagnostic delay varied. Among seven patients, pnevmonia was initially diagnosed in two, who were treated ; one had multiorgan failure, and one was suffering from pericardial effusion and lung abscess. In three other patients, chest radiographs initially showed non-specific findings, leading to delayed CT examination. The most common cause of mediastinitis was esophageal rupture, and in these patients, chest radiographs and clinical

  5. Findings chest radiograph and CT in mediastinitis: effcacy of CT in patients with delayed diagnosis

    International Nuclear Information System (INIS)

    Son, Eun Ju; Hong, Yong Kook; Choe, Kyu Ok

    1999-01-01

    To analyse the causes the radiologic findings in patients with mediastinitis and to evaluate the efficacy of chest CT scanning in patients with delayed diagnosis. Seventeen patients with histopathologically(n=15) or clinically diagnosed(n=2) mediastinitis were involved in this study. Eleven of the former group underwent surgery, and in four, tube drainage was performed. All underwent chest radiography and CT scanning, and in seven patients, the causes of delayed diagnosis were analysed. The most common cause of mediastinitis was esophageal rupture(n=11). Others were extension from neck abscess to the mediastinum(n=3), complications after a Benthall procedure(n=1), tuberculous lymphadenitis(n=1) and mycotic aneurysm(n=1). Patients with esophageal rupture suffered from underlying diseases such as esophageal cancer(n=2), iatrogenic esophageal rupture(n=2), Boerhaave's syndrome(n=2), and esophagitis(n=1). In patients with neck abscess (n=3), each was secondary to infected cystic hygroma, Ludwig angina, or deep neck infection, respectively. On chest CT, patients with esophageal rupture(n=11) had an abscess in the posterior mediastinum ; nine abscesses extended to the cervical area along the retropharyngeal space, and the patient with Ludwig angina had an abscess involving all compartments of the mediastinum. Among the total of 17 patients, diagnostic delays were found in seven, while five had spontaneous esophageal ruptures and two suffered complications after a Benthall procedure and Tbc lymphadenitis, respectively. The causes of diagnostic delay varied. Among seven patients, pnevmonia was initially diagnosed in two, who were treated ; one had multiorgan failure, and one was suffering from pericardial effusion and lung abscess. In three other patients, chest radiographs initially showed non-specific findings, leading to delayed CT examination. The most common cause of mediastinitis was esophageal rupture, and in these patients, chest radiographs and clinical symptoms

  6. Potential of ultrasound in the pediatric chest

    Energy Technology Data Exchange (ETDEWEB)

    Trinavarat, Panruethai, E-mail: pantrinavarat@hotmail.com [Department of Radiology, Faculty of Medicine, Chulalongkorn University, Rama IV Road, Pathumwan, Bangkok 10330 (Thailand); Riccabona, Michael, E-mail: michael.riccabona@klinikum-graz.at [Department of Radiology, Division of Pediatric Radiology, University Hospital Graz (Austria)

    2014-09-15

    Ultrasound (US) of chest, even with inherent limitations of the US beam and air, has been useful in many pediatric chest conditions. It has extended its role and is now widely used by many subspecialists in medicine. This review article will cover techniques, indications, and applications of chest US in neonates, infants and children, including also different common as well as some rare and modern aspects and applications, such as pleural effusion, pneumothorax, pulmonary lesions, mediastinum, diaphragm, and chest wall. Other related imaging modalities are also briefly discussed.

  7. Chest pain in focal musculoskeletal disorders

    DEFF Research Database (Denmark)

    Stochkendahl, Mette Jensen; Christensen, Henrik Wulff

    2010-01-01

    overlapping conditions and syndromes of focal disorders, including Tietze syndrome, costochondritis, chest wall syndrome, muscle tenderness, slipping rib, cervical angina, and segmental dysfunction of the cervical and thoracic spine, have been reported to cause pain. For most of these syndromes, evidence......The musculoskeletal system is a recognized source of chest pain. However, despite the apparently benign origin, patients with musculoskeletal chest pain remain under-diagnosed, untreated, and potentially continuously disabled in terms of anxiety, depression, and activities of daily living. Several...... arises mainly from case stories and empiric knowledge. For segmental dysfunction, clinical features of musculoskeletal chest pain have been characterized in a few clinical trials. This article summarizes the most commonly encountered syndromes of focal musculoskeletal disorders in clinical practice....

  8. Fatigue analysis of a PWR steam generator tube sheet

    International Nuclear Information System (INIS)

    Billon, F.; Buchalet, C.; Poudroux, G.

    1985-01-01

    The fatigue analysis of a PWR steam generator (S.G) tube sheet is threefold. First, the flow, pressure and temperature variations during the design transients are defined for both the primary fluid and the normal and auxiliary feedwater. Second, the flow, velocities, pressure and temperature variations of the secondary fluid at the bottom of the downcomer and above the tube sheet are determined for the transients considered. Finally, the corresponding temperatures and stresses in the tube sheet are calculated and the usage factors determined at various locations in the tube sheet. The currently available standard design transients for the primary fluid and the feedwater are too conservative to be utilized as such in the fatigue analysis of the S.G. tube sheets. Thus, a detailed examination and reappraisal of each operating transient was performed. The revised design conditions are used as inputs to the calculation model TEMPTRON. TEMPTRON determines the mixing conditions between the feedwater and the recirculation fluid from the S.G. feedwater nozzles to the center of the tube sheet via the downcomer. The fluid parameters, flow rate and velocity, temperature and pressure variations, as a function of the time during the transients are obtained. Finally, the usage factors at various locations on the tube sheet are derived using the standard ASME section III method

  9. Development of a running robot in super high speed tube. Aiming at realization of in-tube inspection for primary cooler and so forth of nuclear reactor

    International Nuclear Information System (INIS)

    Kato, Shigeo

    2000-01-01

    Authors have carried out a study on an in-tube running robot in living body on a base of laying stretching of bellows at a means of running by thinking application of in-tube inspection in living body such as large and small bowels. As a result, an in-tube running robot with about 20 mm in inner diameter capable of running in soft small bowel as well as in hard running tube was developed successfully. After an accident of the Tsuruga nuclear power plant, inspection of a large diameter tube with 76 mm in inner diameter was found to be much important, to begin development of an in-tube running robot for 50 mm class diameter tube. As a result, an in-tube running robot capable of enough holding a micro video camera with about 20 g in mass and showing 4.6 N in tension at more than ten times higher speed of 248 mm/s in no loading state, could be made in trial. Here was reported on a foothold realizable on an in-tube running robot for the 76 mm class large diameter tube to be investigated in future. (G.K.)

  10. Instructions to "push as hard as you can" improve average chest compression depth in dispatcher-assisted cardiopulmonary resuscitation.

    Science.gov (United States)

    Mirza, Muzna; Brown, Todd B; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S

    2008-10-01

    Cardiopulmonary resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to "push as hard as you can" in the simplified protocol, compared to "push down firmly 2in. (5cm)" in MPDS. Data were recorded via a Laerdal ResusciAnne SkillReporter manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Instructions to "push as hard as you can", compared to "push down firmly 2in. (5cm)", resulted in improved chest compression depth (36.4 mm vs. 29.7 mm, pCPR instructions by changing "push down firmly 2in. (5cm)" to "push as hard as you can" achieved improvement in chest compression depth at no cost to total release or average chest compression rate.

  11. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  12. Chest CT in children: anesthesia and atelectasis

    International Nuclear Information System (INIS)

    Newman, Beverley; Gawande, Rakhee; Krane, Elliot J.; Holmes, Tyson H.; Robinson, Terry E.

    2014-01-01

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  13. Stress corrosion cracking of steam generator tube and primary pipe in PWR type nuclear power plants

    International Nuclear Information System (INIS)

    Zhang Weiguo; Gao Fengqin; Zhou Hongyi

    1992-03-01

    The behavior of stress corrosion cracking (SCC) was studied by slow strain rate test (SSRT), constant load test (CLT) and low frequency cyclic loading test (LFCLT). The purpose of these tests is to get the test data for evaluating the integrity of pressurized boundary of pipes in Qinshan and Guangdong nuclear power plants (NPPs). Tested materials are 316 nuclear grade stainless steel (SS) for primary pipes in welded heat affected zone (WHAZ) and tubes of heat transfer, such as Incoloy-800, Inconel-600 and 321 SS which are used for steam generator in PWR NPPs. The effects of material metallurgy, shot peening treatment, tensile load, strain rate, cyclic load and water chemistry on the behavior of SCC were considered

  14. Stress corrosion cracking of steam generator tube and primary pipe in PWR type nuclear power plants

    International Nuclear Information System (INIS)

    Zhang Weiguo; Gao Fengqin; Zhou Hongyi

    1993-01-01

    The behavior of stress corrosion cracking (SCC) is studied by slow strain rate test (SSRT), constant load test (CLT) and low frequency cyclic loading test (LFCLT). The purpose of these tests is to get the test data for evaluating the integrity of pressurized boundary of pipes in Qinshan and Guangdong nuclear power plants. Tested materials are 316 nuclear grade stainless steel (SS) for primary pipes in welded heat affected zone (WHAZ) and steam generator tubes, such as Incoloy-800, Inconel-600, Inconel-690 and 321 SS which are used for steam generator in PWR. The effects of material metallurgy, shot-peening treatment, tensile load, strain rate, cyclic load and water chemistry on the behavior of SCC are investigated

  15. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  16. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT

    International Nuclear Information System (INIS)

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J.; Maentele, Werner; Bauer, Ralf W.

    2012-01-01

    Highlights: ► The dual-energy protocol delivers the lowest effective dose of the investigated protocols for standard chest CT examinations, thus enabling functional imaging (like dual-energy perfusion) and can produce weighted images without dose penalty. ► The high-pitch protocol goes along with a 16% increase in dose compared to the standard 120 kV protocol and thus should preferably be used in pediatric, acute care settings (e.g. pulmonary embolism, aortic dissection and the like) or restless patients. ► The difference in effective dose estimates between ICRP 60 and 103 is minimal. ► Tube potential definitely has an effect on estimates of effective dose. - Abstract: Purpose: To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Materials and methods: Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014 mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120 kV, (2) single-source 100 kV, (3) high-pitch 120 kV, and (4) dual-energy with 100/Sn140 kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. Results: DLP-based estimates differed by 4.5–16.56% and 5.2–15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04 m

  17. Dual-source CT in chest pain diagnosis

    International Nuclear Information System (INIS)

    Johnson, Thorsten R.C.; Nikolaou, K.; Fink, C.; Rist, C.; Reiser, M.F.; Becker, C.R.; Becker, A.; Knez, A.

    2007-01-01

    With the depiction of pulmonary arteries, coronary arteries, and the aorta, CT angiography of the chest offers a comprehensive diagnostic work-up of unclear chest pain. The aim of this study was to assess the diagnostic accuracy of dual-source CT in this patient group. A total of 47 patients suffering from unclear chest pain were examined with a Siemens Somatom Definition. Volume and flow of contrast media (Ultravist, Schering) were adapted to the body weight. The examinations were evaluated with regard to image quality and contrast opacification and to the diagnostic accuracy with reference to the final clinical diagnosis. Adequate contrast opacification was achieved in all examinations. The depiction of the coronary arteries was diagnostic in all cases. The cause of chest pain could be identified in 41 cases. Among the diagnoses were coronary and myocardial pathologies, valvular disease, aortic aneurysms and dissections, pulmonary embolism, and pneumonic consolidation. DSCT angiography of the chest offers a very good image quality even at high heart rates so that a high diagnostic accuracy is achieved in patients with acute chest pain. (orig.) [de

  18. Tube vibration in industrial size test heat exchanger

    International Nuclear Information System (INIS)

    Halle, H.; Wambsganss, M.W.

    1980-03-01

    Tube vibration data from tests of a specially built and instrumented, industrial-type, shell-and-tube heat exchanger are reported. The heat exchanger is nominally 0.6 m (2 ft) in dia and 3.7 m (12 ft) long. Both full tube and no-tubes-in-window bundles were tested for inlet/outlet nozzles of different sizes and with the tubes supported by seven, equally-spaced, single-segmental baffles. Prior to water flow testing, natural frequencies and damping of representative tubes were measured in air and water. Flow testing was accomplished by increasing the flow rates in stepwise fashion and also by sweeping through a selected range of flow rates. The primary variables measured and reported are tube accelerations and/or displacements and pressure drop through the bundle. Tests of the full tube bundle configuration revealed tube rattling to occur at intermediate flow rates, and fluidelastic instability, with resultant tube impacting, to occur when the flow rate exceeded a threshold level; principally, the four-span tubes were involved in the regions immediately adjacent to the baffle cut. For the range of flow rates tested, fluidelastic instability was not achieved in the no-tubes-in-window bundle; in this configuration the tubes are supported by all seven baffles and are, therefore, stiffer

  19. Advances in chest drain management in thoracic disease

    Science.gov (United States)

    George, Robert S.

    2016-01-01

    An adequate chest drainage system aims to drain fluid and air and restore the negative pleural pressure facilitating lung expansion. In thoracic surgery the post-operative use of the conventional underwater seal chest drainage system fulfills these requirements, however they allow great variability amongst practices. In addition they do not offer accurate data and they are often inconvenient to both patients and hospital staff. This article aims to simplify the myths surrounding the management of chest drains following chest surgery, review current experience and explore the advantages of modern digital chest drain systems and address their disease-specific use. PMID:26941971

  20. The impact of steam generator replacement on PWR primary system contamination

    International Nuclear Information System (INIS)

    Dacquait, F.; Marteau, H.; Guinard, L.; Ranchoux, G.; Taunier, S.; Wintergerst, M.; Bretelle, J.L.; Rocher, A.

    2010-01-01

    This paper analyses the impact of Steam Generator Replacement (SGR) on PWR primary circuit contamination. It presents a comparison of the activities deposited inside the primary system and released during refuelling outages after SGR with three different SG tube alloys (600, 690 and 800) and different SG tube manufacturing processes. A SGR has a great impact on the primary system contamination. After SGR, whatever the SG tube material is, the typical variations are the following: The 58 Co contamination increases for 1 to 3 cycles, and then decreases to very low levels in some cases, mainly depending on the manufacturing process of the replacement SG tubes; The 60 Co Co contamination tends to decrease on the primary coolant pipes and increases by a lower rate on the new SG tubes. This analysis highlights the importance on contamination levels after SGR of both the corrosion product deposits on the primary surfaces before SGR and the surface finish of the SG tubes related to their manufacturing process. (author)

  1. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    Science.gov (United States)

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Can "YouTube" help students in learning surface anatomy?

    Science.gov (United States)

    Azer, Samy A

    2012-07-01

    In a problem-based learning curriculum, most medical students research the Internet for information for their "learning issues." Internet sites such as "YouTube" have become a useful resource for information. This study aimed at assessing YouTube videos covering surface anatomy. A search of YouTube was conducted from November 8 to 30, 2010 using research terms "surface anatomy," "anatomy body painting," "living anatomy," "bone landmarks," and "dermatomes" for surface anatomy-related videos. Only relevant video clips in the English language were identified and related URL recorded. For each videotape the following information were collected: title, authors, duration, number of viewers, posted comments, and total number of days on YouTube. The data were statistically analyzed and videos were grouped into educationally useful and non-useful videos on the basis of major and minor criteria covering technical, content, authority, and pedagogy parameters. A total of 235 YouTube videos were screened and 57 were found to have relevant information to surface anatomy. Analysis revealed that 15 (27%) of the videos provided useful information on surface anatomy. These videos scored (mean ± SD, 14.0 ± 0.7) and mainly covered surface anatomy of the shoulder, knee, muscles of the back, leg, and ankle, carotid artery, dermatomes, and anatomical positions. The other 42 (73%) videos were not useful educationally, scoring (mean ± SD, 7.4 ± 1.8). The total viewers of all videos were 1,058,634. Useful videos were viewed by 497,925 (47% of total viewers). The total viewership per day was 750 for useful videos and 652 for non-useful videos. No video clips covering surface anatomy of the head and neck, blood vessels and nerves of upper and lower limbs, chest and abdominal organs/structures were found. Currently, YouTube is an inadequate source of information for learning surface anatomy. More work is needed from medical schools and educators to add useful videos on YouTube

  3. Comparative study of the Quality Control of x-ray tubes and generators in hospital assistance and primary assistance in Galician autonomous community

    International Nuclear Information System (INIS)

    Pombar Camean, M.; Lobato Busto, R.

    1992-01-01

    The quality guarantee in Diagnostic Radiology is defined as the organized effort of surgical staff to guarantee sufficient quality images, which provide the correct diagnostic information, as cheaply as possible and with the least exposure to radiation for the patient. In this paper a comparative study about the quality control of x-ray tube and generators in hospital assistance and primary assistance is present. In the conclusions, it is confirmed that the antiquity and poor conservation of the primary attendance x-ray equipment, have influence on the studied constants and therefore, influence the doses received by the patients. (author)

  4. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    Science.gov (United States)

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  5. Feasibility study of automatic tube current modulation in low-dose thoracic imaging for young children with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Peng Yun; Li Jianyin; Zhang Qifeng; Liu Yue; Wang Bei; Zheng Jinjin

    2008-01-01

    Objective: To assess the feasibility of using an automatic tube current modulation (ATCM) method to obtain consistent image quality with reduced radiation dose for young children undergoing chest scans with a set of 64-slice spiral CT. Methods: Fifty young children underwent chest scans on a GE 64-slice VCT with automatic tube current modulation. The noise index (NI) for this study group was set to 8 or 9 based on the proposed reference for pediatric chest imaging in our hospital. We compared image quality and radiation dose for the study group with the age-matched control group of 50 young children acquired with standard protocol of fixed-mAs (120 and 150 mAs for under 1 and above 1 year old, respectively). The volume CT dose index(CTDIvol) values were recorded for both groups. Two experienced pediatric radiologists assessed image quality on a 5-point scale with 5 being the best. Scores greater than or equal to 3 were considered clinically acceptable. The degree of interobserver concordance was determined by Kappa statistics. Results: The average objective image noise and CTDIvol for control group was (4.78±0.58) and (6.68±0.62) mGy, respectively. For the study group the mean value of objective mAs was (41.6±11.6) (20-79 mAs) with mean CTDIvol of (2.34±0.71) mGy, and the use of ATCM produced mean noise of (7.84±0.66). The average CTDIvol with the use of NI of 8-9 was about 65% lower than that with the fixed mAs setting. The mean image quality score for the study group and control group was (3.46±0.40) and (4.65±0.46) respectively. All studies had acceptable image quality, and there was good inter-observer agreement in diagnostic acceptability (Kappa=0.474 and 0.536). Conclusion: The automatic tube current modulation method could be used to obtain consistent image quality for young children undergoing 64-slice MSCT chest scans. With proper noise level setting (NI=8 or 9), one may obtain clinically acceptable images with much reduced radiation dose. (authors)

  6. Pressure loss characteristics of LSTF steam generator heat-transfer tubes. Pressure loss increase due to tube internal instruments

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro

    1994-11-01

    The steam generator of the Large-Scale Test Facility (LSTF) includes 141 heat-transfer U-tubes with different lengths. Six U-tubes among them are furnished with 15 or 17 probe-type instruments (conduction probe with a thermocouple; CPT) protuberant into the primary side of the U-tubes. Other 135 U-tubes are not instrumented. This results in different hydraulic conditions between the instrumented and non-instrumented U-tubes with the same length. A series of pressure loss characteristics tests was conducted at a test apparatus simulating both types of U-tube. The following pressure loss coefficient (K CPT ) was reduced as a function of Reynolds number (Re) from these tests under single-phase water flow conditions. K CPT =0.16 5600≤Re≤52820, K CPT =60.66xRe -0.688 2420≤Re≤5600, K CPT =2.664x10 6 Re -2.06 1371≤Re≤2420. The maximum uncertainty is 22%. By using these results, the total pressure loss coefficients of full length U-tubes were estimated. It is clarified that the total pressure loss of the shortest instrumented U-tube is equivalent to that of the middle-length non-instrumented U-tube and also that a middle-length instrumented U-tube is equivalent to the longest non-instrumented U-tube. Concludingly. it is important to take account of the CPT pressure loss mentioned above in estimation of fluid behavior at the non-instrumented U-tubes either by using the LSTF experiment data from the CPT-installed U-tubes or by using any analytical codes. (author)

  7. Imaging of chest wall infections

    International Nuclear Information System (INIS)

    Chelli Bouaziz, Mouna; Jelassi, Helmi; Chaabane, Skander; Ladeb, Mohamed Fethi; Ben Miled-Mrad, Khaoula

    2009-01-01

    A wide variety of infections can affect the chest wall including pyogenic, tuberculous, fungal, and some other unusual infections. These potentially life-threatening disorders are frequent especially among immunocompromised patients but often misdiagnosed by physical examination and radiographs. The purpose of this article is to describe the clinical and imaging features of these different chest wall infections according to the different imaging modalities with emphasis on ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI). The outcome of chest wall infection depends on early diagnosis, severity of the immunosuppression, offending organism, and extent of infection. Because clinical findings and laboratory tests may be not contributive in immunocompromised patients, imaging plays an important role in the early detection and precise assessment of the disease. US, CT, and MRI are all useful: bone destruction is more accurately detected with CT whereas soft tissue involvement are better visualized with US and MRI. CT and US are also used to guide percutaneous biopsy and drainage procedures. MR images are helpful in pre-operative planning of extensive chest wall infections. (orig.)

  8. Low Yield of Chest Radiography in a Large Tuberculosis Screening Program1

    Science.gov (United States)

    Pollock, Nira R.

    2010-01-01

    Purpose: To assess the frequency and spectrum of abnormalities on routine screening chest radiographs in the pre-employment evaluation of health care workers with positive tuberculin skin test (TST) results. Materials and Methods: The institutional review board approved this HIPAA-compliant retrospective study and waived the need for written informed patient consent. Chest radiographic reports of all 2586 asymptomatic individuals with positive TST results who underwent pre-employment evaluation between January 1, 2003, and December 31, 2007, were evaluated to determine the frequency of detection of evidence of active tuberculosis (TB) or latent TB infection (LTBI) and the spectrum of imaging findings. All chest radiographs interpreted as positive were reviewed by an experienced board-certified radiologist. If there was a discrepancy between the two readings, a second experienced radiologist served as an independent and final arbiter. Any follow-up chest radiographs or computed tomographic images that had been acquired by employee health services or by the employee’s private physician as a result of a suspected abnormality detected at initial screening were also evaluated. Results: Of the 159 (6.1%) chest radiographic examinations that yielded abnormal results, there were no findings that were consistent with active TB. There were 92 cases of calcified granulomas, calcified lymph nodes, or both; 25 cases of apical pleural thickening; 16 cases of fibrous scarring; and 31 cases of noncalcified nodules. All cases of fibrous scarring involved an area smaller than 2 cm2. All noncalcified nodules were 4 mm in diameter or smaller, with the exception of one primary lung malignancy and one necrotizing granuloma (negative for acid-fast bacilli) that grew Mycobacterium kansasii on culture. Conclusion: Universal chest radiography in a large pre-employment TB screening program was of low yield in the detection of active TB or increased LTBI reactivation risk, and it provided

  9. Calculation of the Cardiothoracic Ratio from Portable Anteroposterior Chest Radiography

    Science.gov (United States)

    Chon, Sung Bin; Oh, Won Sup; Cho, Jun Hwi; Kim, Sam Soo

    2011-01-01

    Cardiothoracic ratio (CTR), the ratio of cardiac diameter (CD) to thoracic diameter (TD), is a useful screening method to detect cardiomegaly, but is reliable only on posteroanterior chest radiography (chest PA). We performed this cross-sectional 3-phase study to establish reliable CTR from anteroposterior chest radiography (chest AP). First, CDChest PA/CDChest AP ratios were determined at different radiation distances by manipulating chest computed tomography to simulate chest PA and AP. CDChest PA was inferred from multiplying CDChest AP by this ratio. Incorporating this CD and substituting the most recent TDChest PA, we calculated the 'corrected' CTR and compared it with the conventional one in patients who took both the chest radiographies. Finally, its validity was investigated among the critically ill patients who performed portable chest AP. CDChest PA/CDChest AP ratio was {0.00099 × (radiation distance [cm])} + 0.79 (n = 61, r = 1.00, P chest AP with an available previous chest PA. This might help physicians detect congestive cardiomegaly for patients undergoing portable chest AP. PMID:22065900

  10. Comparison of image quality among three x-ray systems for chest radiography: first step in optimisation

    International Nuclear Information System (INIS)

    Nocetti, D.; Ubeda, C.; Calcagno, S.; Acevedo, J.; Pardo, D.

    2015-01-01

    The aim of this study was to compare the performance of three digital X-ray systems [one flat-panel (DR) and two computed radiography (CR)] for chest radiography in terms of the entrance surface air kerma (ESAK) delivered to a polymethyl methacrylate phantom of 20 cm (equivalent to an adult patient) and image quality through of numerical evaluations using a test object (TO). The tube charge applied was ranged from 0.6 to 32 mAs, to a fixed tension of 125 kVp. The DR system presented the highest mean values of ESAK (615.9 μGy) along with the highest signal-to-noise ratio values, whereas CR systems showed a better high-contrast spatial resolution. Differences were statistically significant in both cases regarding the tube charge used. Thus, this parameter should be mainly considered to optimise the radiological protection through exposure settings selected. This survey represents the first effort to achieve optimisation in digital radiology for Chile. (authors)

  11. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  12. N Reactor pressure tube 1350 postirradiation examination

    International Nuclear Information System (INIS)

    Cook, D.J.

    1977-01-01

    The N Reactor pressure tubes were fabricated from Zircaloy-2 primarily due to the excellent corrosion resistance, low neutron absorption, and high strength properties of this alloy. Irradiation damage mechanisms increase the strength and decrease the ductility of the Zircaloy-2. Irradiation data available at the time the tubes were installed indicated that fast neutron irradiation damage mechanisms would not decrease the ductility to unacceptable levels over the estimated plant life of 25 to 30 years. However, because the tubes are a primary coolant system component and only limited data are available on irradiation effects at high fluences, a Postirradiation Examination (PIE) program was developed to assure that service factors do not compromise pressure tube integrity essential to reactor safety. The PIE program requires that a pressure tube be periodically removed from the reactor for destructive testing. The N Reactor Technical Specifications specify that the frequency of pressure tube removal and examination be based upon the previous PIE test results. Four pressure tubes were examined before tube 1350, and the test results were summarized in individual reports. PIE results on tube 1350 were summarized along with the test results on the previous four tubes in a previous report. The purpose of this report is to present in detail the results on PIE of pressure tube 1350, and, in particular, document the technique by which the fracture toughness of the pressure tube was determined

  13. Integrity evaluation of Alloy 600 RV head penetration tubes in Korean PWR plants

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Park, Sung Ho; Hong, Sung Yull; Choi, Kwang Hee

    1995-01-01

    The structural integrity assessment of Alloy 600 RV head penetration tubes has been an important issue for the economical and reliable operation of power plants. In this paper, an overview of the integrity evaluation program for the RV head penetration tubes in Korean nuclear power plants is presented. Since the crack growth mechanism of the penetration tube is due to the primary water stress corrosion cracking (PWSCC) which is mainly related to the stress at the tube, the present paper consists of three primary activities: the stress evaluation, the flaw evaluation, and data generation through material and mechanical tests. (author). 5 refs, 2 figs, 1 tab

  14. A close or positive margin after mastectomy is not an indication for chest wall irradiation except in women aged fifty or younger

    International Nuclear Information System (INIS)

    Freedman, G.M.; Fowble, B.L.; Hanlon, A.L.; Myint, M.A.; Hoffman, J.P.; Sigurdson, E.R.; Eisenberg, B.L.; Goldstein, L.J.; Fein, D.A.

    1997-01-01

    Purpose: Indications for postmastectomy radiation include primary tumor size > 5 cm and ≥ 4 positive axillary nodes. In clinical practice, patients with a close or positive margin after mastectomy are also often treated with postmastectomy radiation. However, there is little data regarding the risk of a chest wall recurrence in patients with this pathologic feature who otherwise would be considered low risk (tumor size 25% at 8 years: Age ≤ 50 years was 28% vs. 0% for age > 50 (p=0.08). There was no correlation with chest wall failure and number of nodes, ER status, lymphovascular invasion, location of primary, grade, family history or type of tumor close to the margin. All four chest wall failures were in patients who had received adjuvant systemic chemotherapy ± Tamoxifen. Chest wall failures occurred in patients with margins within 1-2 mm in three patients and 5 mm in one patient. The cumulative chest wall recurrence at 8 years by margin proximity was 24% ≤ 2mm vs. 7% 2.1-6 mm (p=0.44), and by clinical size 24% for T2 tumors vs. 7% for T1 (p=0.55). Conclusions: A close or positive margin is uncommon (< 5%) after mastectomy in patients with tumor size < 5 cm and 0-3 positive axillary nodes, but when present it appears to be in a younger patient population. The subgroup of patients aged 50 or younger with clinical T1-T2 tumor size and 0-3 positive nodes who have a close (≤ 5 mm) or positive mastectomy margin are at high risk (28% at 8 years) for chest wall recurrence regardless of adjuvant systemic therapy, and therefore we recommend they be considered for postmastectomy radiation. This high risk of local failure was not observed in patients over age 50, suggesting this subgroup may not require adjuvant chest wall irradiation

  15. The chest

    International Nuclear Information System (INIS)

    Berdon, W.E.

    1985-01-01

    Radiographic interpretation of chest films of newborns in respiratory distress remains one of the most difficult aspects of pediatric radiology. Complex pulmonary and cardiac adjustments to extrauterine life are rapidly taking place. The small, fluid-filled fetal lung must rid itself of fluid and fill with air. The high vascular resistance of the fetal pulmonary bed and the open ductus arteriosus allow shunting of blood in both directions. Films taken in this period of time may show lungs that resemble those seen in congestive heart failure or fluid overload. When these findings are observed in infants who may appear dusky or even cyanotic, the result may be the diagnosis of disease in normal infants passing through a stormy transition period. To make things worse, the films are taken as portable surpine films, usually in an isolette in the intensive care unit (ICU). The phase of respiration is difficult, if not impossible, to control, and lateral films are usually not obtained. Many of the infants are on assisted ventilation either by tube or nasal prongs-nasal continuous positive airway pressure (CPAP)-and lungs can appear over-inflated or whited out, depending on the pressures used and the phase of the respiratory cycle. Prolonged crying itself can make lungs appear semiopaque; the next breath may show such a dramatic reinflation that it is hard to believe the two films are of the same infant, made only seconds apart. Is the heart large? Or is it the thymus? Are the lungs ''wet''? Is there infection? Is there pulmonary vascular engorgement? Why are these films so hard to interpret? They have no easy answers. The radiologist must realize that the neonatal intensive care personnel, armed though they may be with blood gas values, are no better at interpreting films. If anything, they read into them what they wish to see

  16. Primary study for boron neutron capture therapy uses the RSG-GAS beam tube facility

    International Nuclear Information System (INIS)

    Suroso

    2000-01-01

    The minimum epithermal neutron flux as one of the prerequisite of Boron Neutron Capture Therapy (BNCT) is 1.0 x 10 9 n/(cm 2 s) RSG-GAS have 6 beam tube facilities for neutron source, which is one of the beam tube S-2 has a possibility to utilization for BNCT facility. The totally flux neutron measurement in the front of S-2 beam tube is 1.8 x 10 7 n/(cm 2 s). The neutron flux measurement was less than for BNCT minimum prerequisite. Concerning to the flux neutron production in the reactor, which is reach to 2.5 x 10 14 n/(cm 2 s), there for the S-2 beam tube could be used beside collimator modification

  17. Subxyphoid pleural drain confers lesser impairment in respiratory muscle strength, oxygenation and lower chest pain after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Cancio, Andreia S A; Guizilini, Solange; Bolzan, Douglas W; Dauar, Renato B; Succi, José E; de Paola, Angelo A V; Carvalho, Antonio C de Camargo; Gomes, Walter J

    2012-01-01

    To evaluate respiratory muscle strength, oxygenation and chest pain in patients undergoing off-pump coronary artery bypass (OPCAB) using internal thoracic artery grafts comparing pleural drain insertion site at the subxyphoid region versus the lateral region. Forty patients were randomized into two groups in accordance with the pleural drain site. Group II (n = 19) -pleural drain exteriorized in the intercostal space; group (SI) (n = 21) chest tube exteriorized at the subxyphoid region. All patients underwent assessment of respiratory muscle strength (inspiratory and expiratory) on the pre, 1, 3 and 5 postoperative days (POD). Arterial blood gas analysis was collected on the pre and POD1. The chest pain sensation was measured 1, 3 and 5 POD. A significant decrease in respiratory muscle strength (inspiratory and expiratory) was seen in both groups until POD5 (P pleural drainage showed less decrease in respiratory muscle strength, better preservation of blood oxygenation and reduced thoracic pain compared to patients with intercostal drain on early OPCAB postoperative.

  18. OPT-821 With or Without Vaccine Therapy in Treating Patients With Ovarian Epithelial Cancer, Fallopian Tube Cancer, or Peritoneal Cancer in Second or Third Complete Remission

    Science.gov (United States)

    2017-09-12

    Stage IA Fallopian Tube Cancer; Stage IA Ovarian Cancer; Stage IB Fallopian Tube Cancer; Stage IB Ovarian Cancer; Stage IC Fallopian Tube Cancer; Stage IC Ovarian Cancer; Stage IIA Fallopian Tube Cancer; Stage IIA Ovarian Cancer; Stage IIB Fallopian Tube Cancer; Stage IIB Ovarian Cancer; Stage IIC Fallopian Tube Cancer; Stage IIC Ovarian Cancer; Stage IIIA Fallopian Tube Cancer; Stage IIIA Ovarian Cancer; Stage IIIA Primary Peritoneal Cancer; Stage IIIB Fallopian Tube Cancer; Stage IIIB Ovarian Cancer; Stage IIIB Primary Peritoneal Cancer; Stage IIIC Fallopian Tube Cancer; Stage IIIC Ovarian Cancer; Stage IIIC Primary Peritoneal Cancer; Stage IV Fallopian Tube Cancer; Stage IV Ovarian Cancer; Stage IV Primary Peritoneal Cancer

  19. Burst pressure and leak rate from fretted SG tubes

    International Nuclear Information System (INIS)

    Hwang, Seong Sik; Jung, Man Kyo; Kim, Hong Pyo; Kim, Joung Soo

    2005-01-01

    Steam generator(SG) tubes of a pressurized water reactor(PWR) have suffered from various types of corrosion, such as pitting, wastage and stress corrosion cracking (SCC) on both the primary and secondary side. Recently, fretting/wear degradation at the tube support region has been reported in some Korean nuclear power plants. In order to prevent the primary coolant from leaking to the secondary side, the tubes are repaired by a sleeving or plugging. It is important to establish the repair criteria to assure a reactor integrity and yet maintain the plugging ratio within the limits needed for an efficient operation. The objective of the burst test is to obtain a relationship between the burst/leak rate and the shape of the fretted flaws machined with an electro discharge machining (EDM)

  20. Efficacy of Implementation of a Chest Pain Center at a Community Hospital.

    Science.gov (United States)

    Davis, Alexandra; Chiu, Jason; Lau, Stanley K; Kok, Yih Jen; Wu, Jonathan Y H

    2017-12-01

    Chest pain is the second leading cause for emergency department (ED) visits in the United States; however, Asian-based community hospital in the United States. Additionally, this assessment sought to evaluate the effectiveness and safety of a HEART protocol in the first 4 months after its adoption. The facility implemented the CPC, an observation unit, in October 2016. ED physicians risk stratified patients using the HEART score. The guidelines allow ED physicians to stratify patients into 3 categories: to discharge low-risk patients, observe moderate-risk patients in the CPC, and admit high-risk patients. Patients in the CPC received additional diagnostic work-up under the care of ED physicians and cardiologists for less than 24 hours. In addition, CPC patients were followed-up 2 and 30 days after discharge. A total of 172 patients presented at the ED with a chief complaint of chest pain. The majority of the patients were classified into the moderate-risk group (n = 101). Low-risk patients spent significantly less hours in the hospital than the moderate- and high-risk groups, and the high-risk group spent more time in the hospital than the moderate-risk group. The staff followed-up with 74 CPC patients through telephone calls to assess if patients were still experiencing chest pain and if they had followed-up with a cardiologist or primary care physician. The 2- and 30-day survival rates were 100% and 97%, respectively. The data showed a significant reduction in total length of stay for all chest pain patients. This retrospective program evaluation demonstrated some evidence in using HEART score to safely risk stratify chest pain patients to the appropriate level of care. As healthcare moves from a fee-for-service environment to value-based purchasing, hospitals need to devise and implement innovative strategies to provide efficient, beneficial, and safe care for the patients.