WorldWideScience

Sample records for primary air swirler

  1. Ambient air cooling arrangement having a pre-swirler for gas turbine engine blade cooling

    Science.gov (United States)

    Lee, Ching-Pang; Tham, Kok-Mun; Schroeder, Eric; Meeroff, Jamie; Miller, Jr., Samuel R; Marra, John J

    2015-01-06

    A gas turbine engine including: an ambient-air cooling circuit (10) having a cooling channel (26) disposed in a turbine blade (22) and in fluid communication with a source (12) of ambient air: and an pre-swirler (18), the pre-swirler having: an inner shroud (38); an outer shroud (56); and a plurality of guide vanes (42), each spanning from the inner shroud to the outer shroud. Circumferentially adjacent guide vanes (46, 48) define respective nozzles (44) there between. Forces created by a rotation of the turbine blade motivate ambient air through the cooling circuit. The pre-swirler is configured to impart swirl to ambient air drawn through the nozzles and to direct the swirled ambient air toward a base of the turbine blade. The end walls (50, 54) of the pre-swirler may be contoured.

  2. Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

    Science.gov (United States)

    Tedder, Sarah A.; Hicks, Yolanda R.; Tacina, Kathleen M.; Anderson, Robert C.

    2015-01-01

    Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 degrees is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.

  3. Jet flow and premixed jet flame control by plasma swirler

    Energy Technology Data Exchange (ETDEWEB)

    Li, Gang, E-mail: ligang@iet.cn [Key laboratory of light duty gas turbine, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190 (China); Jiang, Xi [School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Zhao, Yujun [School of Mechanism, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044 (China); Liu, Cunxi [Key laboratory of light duty gas turbine, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190 (China); Chen, Qi [School of Mechanism, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044 (China); Xu, Gang; Liu, Fuqiang [Key laboratory of light duty gas turbine, Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190 (China)

    2017-04-04

    A swirler based on dielectric barrier discharge plasma actuators is designed and its effectiveness in both jet flow and premixed jet flame control is demonstrated. In contrast to traditional spanwise-oriented actuators, plasma actuators are placed along the axial direction of the injector to induce a circumferential velocity to the main flow and create a swirl flow without any insertion or moving part. In the DBD plasma swirl injector, the discharge does not ignite the mixture nor does it induce flashback. Flame visualization is obtained by cameras while velocity profiles are obtained by Laser Doppler Anemometry measurements. The results obtained indicate the effectiveness of the new design. - Highlights: • The discharge does not ignite the mixture nor does it induce flashback. • The prominent advantage of this novel plasma swirler is its swirl number adjustable without any mechanical movement. • The frequency of the plasma swirler is adjustable. • The plasma swirler can be used as an oscillator to the reactants. • The plasma swirler can be used alone or combine with other traditional swirlers.

  4. Effect of boundary conditions on downstream vorticity from counter-rotating swirlers

    Directory of Open Access Journals (Sweden)

    Weiye Huo

    2015-02-01

    Full Text Available Particle image velocimetry (PIV is utilized to measure the non-reacting flow field in a reflow combustor with multiple and single swirlers. The velocity field, vortex structure and total vorticity levels are experimentally obtained using two different boundary conditions, representing a single confined swirler and multiple swirlers in an annular combustor. The influence of the boundary conditions on the flow field at several locations downstream of the swirlers is experimentally investigated, showing that the central vortex in the multi-swirler case is more concentrated than in the single-swirler case. The vorticity of the central vortex and average cross-sectional vorticity are relatively low at the swirler outlet in both cases. Both of these statistics gradually increase to the maximum values near 20 mm downstream of the swirler outlet, and subsequently decrease. It is also found that the central vortex in the multi-swirler case is consistently greater than the single-swirler case. These results demonstrate the critical influence of boundary conditions on flow characteristic of swirling flow, providing insight into the difference of the experiments on test-bed combustor and the full-scale annular combustors.

  5. Physical Profiling Performance of Air Force Primary Care Providers

    Science.gov (United States)

    2017-08-09

    AFRL-SA-WP-TR-2017-0014 Physical Profiling Performance of Air Force Primary Care Providers Anthony P. Tvaryanas1; William P...COVERED (From – To) September 2016 – January 2017 4. TITLE AND SUBTITLE Physical Profiling Performance of Air Force Primary Care Providers...encounter with their primary care team. An independent medical standards subject matter expert (SME) reviewed encounters in the electronic health record

  6. 78 FR 47191 - Air Quality Designations for the 2010 Sulfur Dioxide (SO2) Primary National Ambient Air Quality...

    Science.gov (United States)

    2013-08-05

    ... Air Quality Designations for the 2010 Sulfur Dioxide (SO[bdi2]) Primary National Ambient Air Quality... air quality designations for certain areas in the United States for the 2010 primary Sulfur Dioxide (SO 2 ) National Ambient Air Quality Standard (NAAQS). The EPA is issuing this rule to identify areas...

  7. Computational comparison of the effect of mixing grids of 'swirler' and 'run-through' types on flow parameters and the behavior of steam phase in WWER fuel assemblies

    International Nuclear Information System (INIS)

    Shcherbakov, S.; Sergeev, V.

    2011-01-01

    The results obtained using the TURBOFLOW computer code are presented for the numerical calculations of space distributions of coolant flow, heating and boiling characteristics in WWER fuel assemblies with regard to the effect of mixing grids of 'Swirler' and 'Run-through' types installed in FA on the above processes. The nature of the effect of these grids on coolant flow was demonstrated to be different. Thus, the relaxation length of cross flows after passing a 'Run-through' grid is five times as compared to a 'Swirler'-type grid, which correlates well with the experimental data. At the same time, accelerations occurring in the flow downstream of a 'Swirler'-type grid are by an order of magnitude greater than those after a 'Run-through' grid. As a result, the efficiency of one-phase coolant mixing is much higher for the grids of 'Run-through' type, while the efficiency of steam removal from fuel surface is much higher for 'Swirler'-type grids. To achieve optimal removal of steam from fuel surface it has been proposed to install into fuel assemblies two 'Swirler'-type grids in tandem at a distance of about 10 cm from each other with flow swirling in opposite directions. 'Run-through' grids would be appropriate for use for mixing in fuel assemblies with a high non-uniformity of fuel-by-fuel power generation. (authors)

  8. 76 FR 9409 - National Emission Standards for Hazardous Air Pollutants: Primary Lead Smelting

    Science.gov (United States)

    2011-02-17

    ... National Emission Standards for Hazardous Air Pollutants: Primary Lead Smelting; Proposed Rule #0;#0... Emission Standards for Hazardous Air Pollutants: Primary Lead Smelting AGENCY: Environmental Protection... standards for hazardous air pollutants (NESHAP) for Primary Lead Smelting to address the results of the...

  9. 9 CFR 3.15 - Primary conveyances (motor vehicle, rail, air, and marine).

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary conveyances (motor vehicle, rail, air, and marine). 3.15 Section 3.15 Animals and Animal Products ANIMAL AND PLANT HEALTH... conveyances (motor vehicle, rail, air, and marine). (a) The animal cargo space of primary conveyances used to...

  10. 9 CFR 3.138 - Primary conveyances (motor vehicle, rail, air, and marine).

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary conveyances (motor vehicle, rail, air, and marine). 3.138 Section 3.138 Animals and Animal Products ANIMAL AND PLANT HEALTH... (motor vehicle, rail, air, and marine). (a) The animal cargo space of primary conveyances used in...

  11. 9 CFR 3.88 - Primary conveyances (motor vehicle, rail, air, and marine).

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary conveyances (motor vehicle, rail, air, and marine). 3.88 Section 3.88 Animals and Animal Products ANIMAL AND PLANT HEALTH... conveyances (motor vehicle, rail, air, and marine). (a) The animal cargo space of primary conveyances used to...

  12. 9 CFR 3.114 - Primary conveyances (motor vehicle, rail, air and marine).

    Science.gov (United States)

    2010-01-01

    ..., rail, air and marine). 3.114 Section 3.114 Animals and Animal Products ANIMAL AND PLANT HEALTH... conveyances (motor vehicle, rail, air and marine). (a) The animal cargo space of primary conveyances used in.... (e) The interiors of animal cargo spaces in primary conveyances must be kept clean. (f) Live marine...

  13. 9 CFR 3.62 - Primary conveyances (motor vehicle, rail, air, and marine).

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary conveyances (motor vehicle, rail, air, and marine). 3.62 Section 3.62 Animals and Animal Products ANIMAL AND PLANT HEALTH... (motor vehicle, rail, air, and marine). (a) The animal cargo space of primary conveyances used in...

  14. 9 CFR 3.37 - Primary conveyances (motor vehicle, rail, air, and marine).

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary conveyances (motor vehicle, rail, air, and marine). 3.37 Section 3.37 Animals and Animal Products ANIMAL AND PLANT HEALTH... conveyances (motor vehicle, rail, air, and marine). (a) The animal cargo space of primary conveyances used in...

  15. Hazardous air pollutants and primary liver cancer in Texas.

    Directory of Open Access Journals (Sweden)

    Luca Cicalese

    Full Text Available The incidence of hepatocellular carcinoma (HCC, the most common primary liver cancer, is increasing in the US and tripled during the past two decades. The reasons for such phenomenon remain poorly understood. Texas is among continental states with the highest incidence of liver cancer with an annual increment of 5.7%. Established risk factors for HCC include Hepatitis B and C (HBV, HCV viral infection, alcohol, tobacco and suspected risk factors include obesity and diabetes. While distribution of these risk factors in the state of Texas is similar to the national data and homogeneous, the incidence of HCC in this state is exceptionally higher than the national average and appears to be dishomogeneous in various areas of the state suggesting that other non-recognized risk factors might play a role. No population-based studies are currently available investigating the effect of exposure to Hazardous Air Pollutants (HAPs as a contributing risk factor for liver cancer. Incidence rate of liver cancer in Texas by counties for the time period between 2002 and 2012 was obtained from the Texas Cancer Registry (TCR. Through Principal Component Analysis (PCA a subgroup of pollutants, explaining almost all the dataset variability, were identified and used to cluster Texas counties. The analysis generated 4 clusters showing liver cancer rate either higher or lower than national average in association with either high or low levels of HAPs emission in the environment. The study shows that the selected relevant HAPs, 10 among 253 analyzed, produce a significant correlation (P = 0.01-0.05 and some of these have been previously identified as carcinogens. An association between the increased production and consequent exposure to these HAPs and a higher presence of liver cancer in certain counties is suggested. This study provides a new insight on this complex multifactorial disease suggesting that environmental substances might play a role in the etiology of this

  16. Radon in air calibration procedure: A primary method

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markun, F.

    1988-01-01

    A procedure has been developed for preparing 3- to 9-iota volumes of air under natural conditions with a known concentration of /sup 222/Rn to be used for calibrating radon systems. Air is passed into a plastic bag through a standard /sup 226/Ra solution (prepared by the U.S. National Bureau of Standards) contained in an emanation flask. This plastic bag retains /sup 222/Rn with little loss into or through the bag walls. The mean ratios of the /sup 222/Rn in the air at 2 and 7 days after filling to that immediately after filling were -.992 +- 0.006 and 0.969 +- 0.008, which suggests a rate of radon loss into the bag of 0.4 +- 0.1%/day

  17. Examination report: Remote video examination of air slots under the primary tank at 241-AN-107

    International Nuclear Information System (INIS)

    Pedersen, L.T.

    1998-01-01

    This report documents the results of remote video examination of air slots in the insulating concrete slab beneath the primary tank at 241-AN-107. Life Extension Equipment Engineering has selected tank 241-AN-107 for ultrasonic evaluation of tank wall, knuckle, and floor plates. Access to the primary tank floor plates is via the air slots which were formed into the insulating concrete slab during tank construction (reference drawings H-2-71105 and H-2-71160). Prior to deployment of the ultrasonic inspection equipment it is desirable to examine the air slots for obstructions and debris which could impede the ultrasonic equipment. The criteria, equipment description, deliverables, and responsibilities for examination of the air slots are described in HNF-1949, Rev. 0, ''Engineering Task Plan for Remote Video Examination of Air Slots Under the Primary Tank at 241-AN-107''

  18. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    DEFF Research Database (Denmark)

    Nazaroff, W.; Weschler, Charles J.

    2004-01-01

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated...... by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals...... that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which...

  19. Ambient air pollution and primary liver cancer incidence in four European cohorts within the ESCAPE project

    NARCIS (Netherlands)

    Pedersen, Marie; Andersen, Zorana J; Stafoggia, Massimo; Weinmayr, Gudrun; Galassi, Claudia; Sørensen, Mette; Eriksen, Kirsten T; Tjønneland, Anne; Loft, Steffen; Jaensch, Andrea; Nagel, Gabriele; Concin, Hans; Tsai, Ming-Yi; Grioni, Sara; Marcon, Alessandro; Krogh, Vittorio; Ricceri, Fulvio; Sacerdote, Carlotta; Ranzi, Andrea; Sokhi, Ranjeet; Vermeulen, Roel|info:eu-repo/dai/nl/216532620; Hoogh, Kees de; Wang, Meng; Beelen, Rob|info:eu-repo/dai/nl/30483100X; Vineis, Paolo; Brunekreef, Bert|info:eu-repo/dai/nl/067548180; Hoek, Gerard|info:eu-repo/dai/nl/069553475; Raaschou-Nielsen, Ole

    2017-01-01

    BACKGROUND: Tobacco smoke exposure increases the risk of cancer in the liver, but little is known about the possible risk associated with exposure to ambient air pollution. OBJECTIVES: We evaluated the association between residential exposure to air pollution and primary liver cancer incidence.

  20. 3-D Nanofilm Primary Li Air Battery, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA requires a new primary battery capable of providing specific energy exceeding 2000Wh/kg over an operating temperature range of 0oC to 35oC with a shelf life...

  1. Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R.; Imankulov, Eh.R.

    1986-01-01

    Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of nitrogen oxides are formed. Either an increase or decrease in the primary air results in a rise in nitrogen oxide concentration. 3 references.

  2. Yields of primary products from chloroethylenes in air under electron beam irradiation

    International Nuclear Information System (INIS)

    Hakoda, Teruyuki; Hashimoto, Shoji; Kojima, Takuji

    2003-01-01

    The quantitative analysis of toxic primary irradiation products was carried out for the development of the purification technology of chloroethylenes/air mixtures using an electron beam (EB). Degradation of chloroethylenes in humid air proceeded through the formation of primary products retaining a carbon-carbon (C-C) bond such as chloroacetyl chlorides and chloroacetyl aldehyde as well as that of primary products of COCl 2 and HCOCl through C-C bond cleavage. Chloroethylenes having one carbon bonded to two Cl atoms was decomposed into the primary products retaining a C-C bond prior to breaking a C-C bond. The number of Cl atoms of a chloroethylene molecule enhanced the formation ratio of primary products retaining a C-C bond. On the other hand, chloroethylene having two carbons bonded to one Cl atom was degraded thought the scission of a C-C bond predominantly C-C bond maintenance. (author)

  3. Primary design and operation analysis of ITER air transfer system

    International Nuclear Information System (INIS)

    Wang Haitian; Li Ge; Qin Shijun

    2010-01-01

    Air transfer system (ATS) is a remote handling transfer, which can work in the nuclear radiation environment and can be driven by the electricity fully. Its motion power is provided by several servo motors. The remote control technology of ATS, which is China taking part in the plan of international Tokamak experimental reactor (ITER) and grasping this technology, is one of key technologies of ITER. The remote handling technology can lay the foundation for developing demonstration nuclear fusion power plant in China on self-reliance. Because there is gamma irradiation and hazard material in these ITER parts, all required maintenance of port plugs and inner components are been transmitted by ATS. The pick-up or drop-off these components are completed by means of a remotely controlled TCS system between the Vacuum Vessel and the Hot Cell through the bridge-gallery. Tokamak building includes three floors, including upper port, equatorial port and lower port, linked by a lift. According to each port level configuration and safety requirement, the radius of curvature with ATS trajectory is optimized, and a trajectory of each level is determined by positioned guidance beacons. At last, the results of computer aided design (CAD) show single trajectory guidance of ATS in each level is available. (authors)

  4. 40 CFR Appendix P to Part 50 - Interpretation of the Primary and Secondary National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-07-01

    ... the data handling procedures for the reported data). 2.3Comparisons with the Primary and Secondary... Secondary National Ambient Air Quality Standards for Ozone P Appendix P to Part 50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY...

  5. Socio-Economic Consequences of Improved Indoor Air Quality in Danish Primary Schools

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Foldbjerg, Peter; Eriksen, Kurt Emil

    2014-01-01

    are taken into consideration: a) increased PISA score increases productivity; b) increased PISA score reduces the duration of primary education; c) improved indoor air quality reduces absenteeism in teachers. The results show that improved air quality in Danish schools could result in an increase...... in the Gross Domestic Product (GDP) of €173 million per annum, and in the public finances of €37 million per annum...

  6. Chemical pleurodesis for prolonged postoperative air leak in primary spontaneous pneumothorax.

    Science.gov (United States)

    How, Cheng-Hung; Tsai, Tung-Ming; Kuo, Shuenn-Wen; Huang, Pei-Ming; Hsu, Hsao-Hsun; Lee, Jang-Ming; Chen, Jin-Shing; Lai, Hong-Shiee

    2014-05-01

    Prolonged air leak is the most common complication after thoracoscopic operation for primary spontaneous pneumothorax (PSP), and the role of chemical pleurodesis in treating air leaks remains unclear. This study evaluated the safety and efficacy of chemical pleurodesis with a comparison between minocycline and OK-432. Between 1994 and 2011, 1083 PSP patients were treated by thoracoscopic operation. After the operation, patients with persistent air leak for 3 days or more were managed by minocycline or OK-432 pleurodesis. The demographic and outcome data for these patients were collected by retrospective chart review. Seventy-nine patients (7.3%) with prolonged air leak after thoracoscopy underwent minocycline pleurodesis (60 patients) or OK-432 pleurodesis (19 patients) as the primary treatment. The primary success rate was 63% (38/60) for minocycline pleurodesis and 95% (18/19) for OK-432 pleurodesis (p = 0.009). Postpleurodesis pain was common and comparable between the two groups. No major complications were noted after a total of 121 treatments. Patients undergoing primary OK-432 pleurodesis had shorter durations of postpleurodesis chest drainage (mean 8.5 vs. 2.3 days; p < 0.001) and postoperative hospital stay (mean 11.9 vs. 6.8 days; p < 0.001) than those undergoing primary minocycline pleurodesis. After a median follow-up of 16 months, recurrence was noted in one patient in the OK-432 group and none in the minocycline group. Long-term pulmonary function in the two groups was comparable. Chemical pleurodesis using OK-432 or minocycline is safe and convenient for prolonged air leak after thoracoscopic treatment for PSP. Our experience suggested that OK-432 may be more effective than minocycline in reducing air leak. Copyright © 2013. Published by Elsevier B.V.

  7. Electricity generation from fermented primary sludge using single-chamber air-cathode microbial fuel cells

    KAUST Repository

    Yang, Fei; Ren, Lijiao; Pu, Yuepu; Logan, Bruce E.

    2013-01-01

    Single-chamber air-cathode microbial fuel cells (MFCs) were used to generate electricity from fermented primary sludge. Fermentation (30°C, 9days) decreased total suspended solids (26.1-16.5g/L), volatile suspended solids (24.1-15.3g/L) and pH (5

  8. Energy saving opportunity with variable speed drive in primary air-handling unit

    International Nuclear Information System (INIS)

    Li, J.S.M.

    2007-01-01

    Air conditioners used in the court buildings in Kowloon City, Hong Kong were retrofitted with variable speed drives in the primary air handling unit (PAU) in an effort to reduce energy consumption. The initial effect of this retrofit was investigated along with the feasibility of using a carbon dioxide (CO 2 ) based demand control ventilation to reduce energy consumption while optimizing indoor air quality. The air flow in most air conditioning fans is either constant or controlled by motorized inlet guide vanes. Although this controls the flow and may reduce the load on the fan, this constriction adds an energy loss, resulting in inefficient operation. Variable speed drives should be used on the PAU in order to maintain system efficiency. As the speed of the fans are reduced, the flow will decrease proportionally, while the power required by the fan will reduce the cube of the speed. Therefore, if the fresh air supply can be controlled by reducing the speed of the fan motor, then flow control would be more efficient. The energy saving associated with variable fresh air supply flow rate was evaluated along with the cost to building owners. This paper presented the results of the potential energy and cost savings associated with this retrofit, and included implementation cost and pay back period. It was estimated that about 20 per cent of power consumption and electricity costs can be saved per year, with a simple payback period of 2 years. 7 refs., 3 tabs., 3 figs

  9. Corroborating the Land Use Change as Primary Determinant of Air Quality Degradation in a Concentric City

    Directory of Open Access Journals (Sweden)

    Ariva Sugandi Permana

    2015-05-01

    Full Text Available Bandung City is characterized by concentric land use pattern as found in many naturally grown cities. It radiates from mixed commercial areas in the center to low density residential areas in the periphery. This pattern generates significant traffic volume towards city center. The gener-ated traffic releases emissions and degrades urban air quality since fossil fuel is predominantly used by vehicles in Bandung. In the absence of air polluting industries as well as construction and demolition activities, traffic load generated by land use changes is the only major contribu-tor to air quality degradation in the city. The land use change can therefore be seen as primary determinant of air pollution in Bandung. This study analyses land use changes and its impacts on traffic pattern and air quality. Multivariate correlation between traffic load and land use changes is employed as tool to substantiate the proposition. Relationships between the degree of chang-es in land use, as reflected in traffic loads, and the quantity of two principal air pollutants, namely SO2 and HC are also established to validate the argument. The result of analysis sub-stantiates the correlation between land use changes and air quality degradation.

  10. Association between respiratory prescribing, air pollution and deprivation, in primary health care.

    Science.gov (United States)

    Sofianopoulou, Eleni; Rushton, Stephen P; Diggle, Peter J; Pless-Mulloli, Tanja

    2013-12-01

    We investigated the association between respiratory prescribing, air quality and deprivation in primary health care. Most previous studies have used data from secondary and tertiary care to quantify air pollution effects on exacerbations of asthma and chronic obstructive pulmonary disease (COPD). However, these outcomes capture patients who suffer from relatively severe symptoms. This is a population-based ecological study. We analysed respiratory medication (salbutamol) prescribed monthly by 63 primary care practices, UK. Firstly, we captured the area-wide seasonal variation in prescribing. Then, using the area-wide variation in prescribing as an offset, we built a mixed-effects model to assess the remaining variation in relation to air quality and demographic variables. An increase of 10 μg/m(3) in ambient PM10 was associated with an increase of 1% (95% CI: 0.1-2%) in salbutamol prescribing. An increase of 1 SD in income and employment deprivation was associated with an increase of 20.5% (95% CI: 8.8-33.4%) and 14.7% (95% CI: 4.3-26.2%) in salbutamol prescribing rate, respectively. The study provides evidence that monthly respiratory prescribing in primary care is a useful indicator of the extent to which air pollution exacerbates asthma and COPD symptoms. Respiratory prescribing was higher on deprived populations.

  11. Neurobehavioral effects of exposure to traffic-related air pollution and transportation noise in primary schoolchildren.

    Science.gov (United States)

    van Kempen, Elise; Fischer, Paul; Janssen, Nicole; Houthuijs, Danny; van Kamp, Irene; Stansfeld, Stephen; Cassee, Flemming

    2012-05-01

    Children living close to roads are exposed to both traffic noise and traffic-related air pollution. There are indications that both exposures affect cognitive functioning. So far, the effects of both exposures have only been investigated separately. To investigate the relationship between air pollution and transportation noise on the cognitive performance of primary schoolchildren in both the home and school setting. Data acquired within RANCH from 553 children (aged 9-11 years) from 24 primary schools were analysed using multilevel modelling with adjustment for a range of socio-economic and life-style factors. Exposure to NO(2) (which is in urban areas an indicator for traffic-related air pollution) at school was statistically significantly associated with a decrease in the memory span length measured during DMST (χ(2)=6.8, df=1, p=0.01). This remained after additional adjustment for transportation noise. Statistically significant associations were observed between road and air traffic noise exposure at school and the number of errors made during the 'arrow' (χ(2)=7.5, df=1, p=0.006) and 'switch' (χ(2)=4.8, df=1, p=0.028) conditions of the SAT. This remained after adjustment for NO(2). No effects of air pollution exposure or transportation noise exposure at home were observed. Combined exposure of air pollution and road traffic noise had a significant effect on the reaction times measured during the SRTT and the 'block' and the 'arrow' conditions of the SAT. Our results provide some support that prolonged exposure to traffic-related air pollution as well as to noise adversely affects cognitive functioning. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Correlation of high energy muons with primary composition in extensive air shower

    Science.gov (United States)

    Chou, C.; Higashi, S.; Hiraoka, N.; Ozaki, S.; Sato, T.; Suwada, T.; Takahasi, T.; Umeda, H.

    1985-01-01

    An experimental investigation of high energy muons above 200 GeV in extensive air showers has been made for studying high energy interaction and primary composition of cosmic rays of energies in the range 10 to the 14th power approx. 10 to the 15th power eV. The muon energies are estimated from the burst sizes initiated by the muons in the rock, which are measured by four layers of proportional counters, each of area 5 x 2.6 sq m, placed at 30 m.w.e. deep, Funasaka tunnel vertically below the air shower array. These results are compared with Monte Carlo simulations based on the scaling model and the fireball model for two primary compositions, all proton and mixed.

  13. Air ingress behavior during a primary-pipe rupture accident of HTGR

    International Nuclear Information System (INIS)

    Takeda, Tetsuaki

    1997-11-01

    The inherent properties of a HTGR facilitates the design with high degree of passive safe performances, compared to other type. However, it is still not clear if the present HTGR can maintain a passive safe function during a primary-pipe rupture accident, or what would be design criteria to guarantee the HTGR with the high degree of passive safe performances during the accident. To investigate safe characteristics, the study has been performed experimentally and analytically on the air ingress behavior during the accident. It was indicated that there are two stages in the accident of the HTGR having a reverse U-shaped channel. In the first stage, an air ingress process limits molecular diffusion and natural circulation of the gas mixture having a very slow velocity. In the second stage, the air ingress process limits the ordinary natural circulation of air throughout the reactor. A numerical calculation code has been developed to analyze thermal-hydraulic behavior during the first stage. This code provides a numerical method for analyzing a transport phenomena in a multi-component gas system by solving one-dimensional basic equations and using a flow network model. It was possible to predict or analyze the air ingress process regarding the density of the gas mixture, concentration of each gas species and duration of the first stage of the accident. It was indicated that the safe characteristics of the HTGR from the present experiment as follows. The safety cooling rate that the air ingress process terminates during the first stage exists in the HTGR having the reverse U-shaped channel. Moreover, the ordinary natural circulation of air can not produce in the second stage by injecting helium from the bottom of the pressure vessel corresponding the low-temperature side channel. Therefore, it was found that the idea of helium injection is one of useful methods for the prevention of air ingress and of graphite corrosion in the future HTGRs. (J.P.N.). 74 refs

  14. Pre-service primary school teachers’ abilities in explaining water and air pollution scientifically

    Science.gov (United States)

    Lukmannudin; Sopandi, W.; Sujana, A.; Sukardi, R.

    2018-05-01

    The purpose of this study is to determine the ability of pre-service primary school teachers (PSPST) in explaining the phenomenon of water and air pollution scientifically. The research method used descriptive method of analysis with qualitative approach. The respondents were PSPTP at 4th semester. This study used a four-tier instrument diagnostic test. The number of subjects was 84 PSPTP at Universitas Pendidikan Indonesia, Kampus Daerah Sumedang. The results demonstrate the ability of PSPST in explaining water and air pollution scientifically. The results show that only 6% of PSPST who are able to explain the phenomenon of water pollution and only 4% of PSPST who are able to explain the phenomenon of air pollution. The fact should be attention for PSPST because these understanding are crucial in the process of learning activities in the classroom.

  15. The role of primary and secondary air on wood combustion in cookstoves

    Science.gov (United States)

    Kirch, Thomas; Birzer, Cristian H.; Medwell, Paul R.; Holden, Liam

    2018-03-01

    A two-stage solid fuel research furnace was used to examine the claim that through forced draught greater mixing and more complete combustion could be achieved. By varying the primary air (PA) and secondary air (SA) flow the influence on the combustion process was investigated. In the first part of the combustion, when the release of volatile compounds predominates, the variation of neither PA nor SA had a significant influence. In the second part when mainly char is oxidised an increase in both PA and SA lead to a rising nominal combustion efficiency (?)), with a greater impact observed with SA. Furthermore higher air flows caused the heat transfer, to a pot above the furnace, to decline. Therefore forced draught does lead to greater mixing and mitigation of emissions, but in the presented configuration a trade-off between a higher NCE and a lower heat transfer needs consideration.

  16. 40 CFR 50.11 - National primary and secondary ambient air quality standards for oxides of nitrogen (with...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false National primary and secondary ambient air quality standards for oxides of nitrogen (with nitrogen dioxide as the indicator). 50.11 Section 50.11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS NATIONAL...

  17. Electricity generation from fermented primary sludge using single-chamber air-cathode microbial fuel cells

    KAUST Repository

    Yang, Fei

    2013-01-01

    Single-chamber air-cathode microbial fuel cells (MFCs) were used to generate electricity from fermented primary sludge. Fermentation (30°C, 9days) decreased total suspended solids (26.1-16.5g/L), volatile suspended solids (24.1-15.3g/L) and pH (5.7-4.5), and increased conductivity (2.4-4.7mS/cm), soluble COD (2.66-15.5g/L), and volatile fatty acids (1.9-10.1g/L). To lower the COD and increase pH, fermentation supernatant was diluted with primary effluent before being used in the MFCs. The maximum power density was 0.32±0.01W/m2, compared to 0.24±0.03W/m2 with only primary effluent. Power densities were higher with phosphate buffer added to the supernatant (1.03±0.06W/m2) or the solution (0.87±0.05W/m2). Coulombic efficiencies ranged from 18% to 57%, and sCOD removals from 84% to 94%. These results demonstrated that sludge can effectively be used for power generation when fermented and then diluted with only primary effluent. © 2012 Elsevier Ltd.

  18. Trends in European background air reflect reductions in primary emissions of PCBs and PBDEs.

    Science.gov (United States)

    Schuster, Jasmin K; Gioia, Rosalinda; Breivik, Knut; Steinnes, Eiliv; Scheringer, Martin; Jones, Kevin C

    2010-09-01

    Data are presented for polychlorinated biphenyls (PCBs) and polybrominated diphenyls ethers (PBDEs) in passive air samplers (PAS) collected along a rural/remote latitudinal transect from southern UK to northern Norway during 2004-2008. This study is part of an ongoing campaign, using semipermeable membrane devices (SPMDs) as PAS over two year intervals since 1994. Absolute sequestered amounts of selected PCB congeners have decreased in a first order fashion between 1994-2008, with the average time of 8.4+/-3.2 years for atmospheric concentrations to decline by 50%. PCBs have continued to fractionate with latitude during this period. PBDE concentrations declined by 50% between 2000 and 2008 every 2.2+/-0.4 years. Results are discussed in terms of sources, long-range atmospheric transport, global fractionation, and clearance processes. It is concluded that the spatial and temporal trends in background European air mainly reflect the strength of primary diffusive emissions of these compounds and subsequently their ongoing declines. The direct evidence for this is similar rates of decline at all the sites; similar rates of decline for all congeners; no systematic change in the fractionation pattern since 1994. The latest results indicate a reduction in the rate of decline for PCBs (and hence in primary emissions).

  19. Children's Health and Indoor Air Quality in Primary Schools and Homes in Portugal-Study Design.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Ramos, Elisabete; Barros, Henrique; Pereira, Cristiana; Teixeira, João Paulo; Fernandes, Eduardo de Oliveira

    2015-01-01

    The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.

  20. Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China

    Directory of Open Access Journals (Sweden)

    Zhen Peng

    2017-07-01

    Full Text Available Over 70% of a pupil’s school life is spent inside a classroom, and indoor air quality has a significant impact on students’ attendance and learning potential. Therefore, the indoor air quality in primary school buildings is highly important. This empirical study investigates the indoor air quality in four naturally ventilated schools in China, with a focus on four parameters: PM2.5, PM10, CO2, and temperature. The correlations between the indoor air quality and the ambient air pollution, building defects, and occupants’ activities have been identified and discussed. The results indicate that building defects and occupants’ activities have a significant impact on indoor air quality. Buildings with better air tightness have a relatively smaller ratio of indoor particulate matter (PM concentrations to outdoor PM concentrations when unoccupied. During occupied periods, the indoor/outdoor (I/O ratio could be larger than 1 due to internal students’ activities. The indoor air temperature in winter is mainly determined by occupants’ activities and the adiabatic ability of a building’s fabrics. CO2 can easily exceed 1000 ppm on average due to the closing of windows and doors to keep the inside air warmer in winter. It is concluded that improving air tightness might be a way of reducing outdoor air pollutants’ penetration in naturally ventilated school buildings. Mechanical ventilation with air purification could be also an option on severely polluted days.

  1. Copper(I)/TEMPO Catalyzed Aerobic Oxidation of Primary Alcohols to Aldehydes with Ambient Air

    Science.gov (United States)

    Hoover, Jessica M.; Steves, Janelle E.; Stahl, Shannon S.

    2012-01-01

    This protocol describes a practical laboratory-scale method for aerobic oxidation of primary alcohols to aldehydes, using a chemoselective CuI/TEMPO catalyst system. The catalyst is prepared in situ from commercially available reagents, and the reactions are performed in a common organic solvent (acetonitrile) with ambient air as the oxidant. Three different reaction conditions and three procedures for the isolation and purification of the aldehyde product are presented. The oxidations of eight different alcohols, described here, include representative examples of each reaction condition and purification method. Reaction times vary from 20 min to 24 h, depending on the alcohol, while the purification methods each take about 2 h. The total time necessary for the complete protocol ranges from 3 – 26 h. PMID:22635108

  2. Cracking and Corrosion of Composite Tubes in Black Liquor Recovery Boiler Primary Air Ports

    Energy Technology Data Exchange (ETDEWEB)

    Keiser, James R.; Singbeil, Douglas L.; Sarma, Gorti B.; Kish, Joseph R.; Yuan, Jerry; Frederick, Laurie A.; Choudhury, Kimberly A.; Gorog, J. Peter; Jetté, Francois R.; Hubbard, Camden R.; Swindeman, Robert W.; Singh, Prett M.; Maziasz, Phillip J.

    2006-10-01

    Black liquor recovery boilers are an essential part of kraft mills. Their design and operating procedures have changed over time with the goal of providing improved boiler performance. These performance improvements are frequently associated with an increase in heat flux and/or operating temperature with a subsequent increase in the demand on structural materials associated with operation at higher temperatures and/or in more corrosive environments. Improvements in structural materials have therefore been required. In most cases the alternate materials have provided acceptable solutions. However, in some cases the alternate materials have solved the original problem but introduced new issues. This report addresses the performance of materials in the tubes forming primary air port openings and, particularly, the problems associated with use of stainless steel clad carbon steel tubes and the solutions that have been identified.

  3. Overcurrent Abuse of Primary Prismatic Zinc–Air Battery Cells Studying Air Supply Effects on Performance and Safety Shut-Down

    Directory of Open Access Journals (Sweden)

    Fredrik Larsson

    2017-01-01

    Full Text Available Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn–Air battery cells with full air supply as well as with shut-off air supply. Compared to other battery technologies, e.g., lithium-ion batteries, metal–air batteries offer the possibility to physically stop the battery operation by stopping its air supply, thus offering an additional protection against severe battery damage in the case of, e.g., an accidental short circuit. This method may also reduce the electrical hazard in a larger battery system since, by stopping the air supply, the voltage can be brought to zero while maintaining the energy capacity of the battery. Measurements of overdischarge currents and current cut-off by suffocation have been performed to assess the safety of this type of Zn–air battery. The time to get to zero battery voltage is shown to mainly be determined by the volume of air trapped in the cell.

  4. A new approach to the determination of air kerma using primary-standard cavity ionization chambers

    International Nuclear Information System (INIS)

    Burns, D T

    2006-01-01

    A consistent formalism is presented using Monte Carlo calculations to determine the reference air kerma from the measured energy deposition in a primary-standard cavity ionization chamber. A global approach avoiding the use of cavity ionization theory is discussed and its limitations shown in relation to the use of the recommended value for W. The role of charged-particle equilibrium is outlined and the consequent requirements placed on the calculations are detailed. Values for correction factors are presented for the BIPM air-kerma standard for 60 Co, making use of the Monte Carlo code PENELOPE, a detailed geometrical model of the BIPM 60 Co source and event-by-event electron transport. While the wall correction factor k wall = 1.0012(2) is somewhat lower than the existing value, the axial non-uniformity correction k an = 1.0027(3) is significantly higher. The use of a point source in the evaluation of k an is discussed. A comparison is made of the calculated dose ratio with the Bragg-Gray and Spencer-Attix stopping-power ratios, the results indicating a preference for the Bragg-Gray approach in this particular case. A change to the recommended value for W of up to 2 parts in 10 3 is discussed. The uncertainties arising from the geometrical models, the use of phase-space files, the radiation transport algorithms and the underlying radiation interaction coefficients are estimated

  5. Simulation Investigation on Combustion Characteristics in a Four-Point Lean Direct Injection Combustor with Hydrogen/Air

    Directory of Open Access Journals (Sweden)

    Jianzhong Li

    2017-06-01

    Full Text Available To investigate the combustion characteristics in multi-point lean direct injection (LDI combustors with hydrogen/air, two swirl–venturi 2 × 2 array four-point LDI combustors were designed. The four-point LDI combustor consists of injector assembly, swirl–venturi array and combustion chamber. The injector, swirler and venturi together govern the rapid mixing of hydrogen and air to form the mixture for combustion. Using clockwise swirlers and anticlockwise swirlers, the co-swirling and count-swirling swirler arrays LDI combustors were achieved. Using Reynolds-Averaged Navier–Stokes (RANS code for steady-state reacting flow computations, the four-point LDI combustors with hydrogen/air were simulated with an 11 species and 23 lumped reaction steps H2/Air reaction mechanism. The axial velocity, turbulence kinetic energy, total pressure drop coefficient, outlet temperature, mass fraction of OH and emission of pollutant NO of four-point LDI combustors, with different equivalence ratios, are here presented and discussed. As the equivalence ratios increased, the total pressure drop coefficient became higher because of increasing heat loss. Increasing equivalence ratios also corresponded with the rise in outlet temperature of the four-point LDI combustors, as well as an increase in the emission index of NO EINO in the four-point LDI combustors. Along the axial distance, the EINO always increased and was at maximum at the exit of the dump. Along the chamber, the EINO gradually increased, maximizing at the exit of chamber. The total temperature of four-point LDI combustors with different equivalence ratios was identical to the theoretical equilibrium temperature. The EINO was an exponential function of the equivalence ratio.

  6. Spray and Combustion Characteristics of a Novel Multi-circular Jet Plate in Air-assisted Atomizer

    Directory of Open Access Journals (Sweden)

    Hisham Amirnordin Shahrin

    2017-01-01

    Full Text Available Atomization of liquid fuel in air-assisted atomizer is highly dependent on air mixing, which can be enhanced using turbulent generators, such as multi-circular jet (MCJ plates and swirler. This study aims to determine the effects of novel MCJ plates on the spray and combustion characteristics of an air-assisted atomizer by evaluating spray and flame parameters, such as penetration length, cone angle, and cone area. MCJ 30 and MCJ 45, with inclined jets at 30° and 45°, respectively, were used in the experiment. A swirler was also used for comparison. The spray and flame images were recorded at different equivalence ratios through direct photography and analyzed using image J software. Flame temperature was determined using a thermal infrared camera, and burning chamber and flue gas temperatures were measured using thermocouples. The spray and flame characteristics of MCJ 30 exhibited performance comparable with those of the MCJ 45 and swirler. The integration of turbulence and swirling motion concept into the novel MCJ plates can enhance the mixing formation and thus improve the performance of burner combustion.

  7. Temporal trends and spatial variation characteristics of primary air pollutants emissions from coal-fired industrial boilers in Beijing, China

    International Nuclear Information System (INIS)

    Xue, Yifeng; Tian, Hezhong; Yan, Jing; Zhou, Zhen; Wang, Junling; Nie, Lei; Pan, Tao; Zhou, Junrui; Hua, Shenbing; Wang, Yong; Wu, Xiaoqing

    2016-01-01

    Coal-fired combustion is recognized as a significant anthropogenic source of atmospheric compounds in Beijing, causing heavy air pollution events and associated deterioration in visibility. Obtaining an accurate understanding of the temporal trends and spatial variation characteristics of emissions from coal-fired industrial combustion is essential for predicting air quality changes and evaluating the effectiveness of current control measures. In this study, an integrated emission inventory of primary air pollutants emitted from coal-fired industrial boilers in Beijing is developed for the period of 2007–2013 using a technology-based approach. Future emission trends are projected through 2030 based on current energy-related and emission control policies. Our analysis shows that there is a general downward trend in primary air pollutants emissions because of the implementation of stricter local emission standards and the promotion by the Beijing municipal government of converting from coal-fired industrial boilers to gas-fired boilers. However, the ratio of coal consumed by industrial boilers to total coal consumption has been increasing, raising concerns about the further improvement of air quality in Beijing. Our estimates indicate that the total emissions of PM 10 , PM 2.5 , SO 2 , NO x , CO and VOCs from coal-fired industrial boilers in Beijing in 2013 are approximately 19,242 t, 13,345 t, 26,615 t, 22,965 t, 63,779 t and 1406 t, respectively. Under the current environmental policies and relevant energy savings and emission control plans, it may be possible to reduce NO x and other air pollutant emissions by 94% and 90% by 2030, respectively, if advanced flue gas purification technologies are implemented and coal is replaced with natural gas in the majority of existing boilers. - Highlights: • A unit-based emission inventory of coal-fired industrial boilers is developed. • Temporal trend of historical period 2007–2013 and the future till 2030 is

  8. Association of ambient air pollution and meteorological factors with primary care visits at night due to asthma attack.

    Science.gov (United States)

    Yamazaki, Shin; Shima, Masayuki; Yoda, Yoshiko; Oka, Katsumi; Kurosaka, Fumitake; Shimizu, Shigeta; Takahashi, Hironobu; Nakatani, Yuji; Nishikawa, Jittoku; Fujiwara, Katsuhiko; Mizumori, Yasuyuki; Mogami, Akira; Yamada, Taku; Yamamoto, Nobuharu

    2013-09-01

    The association of outdoor air pollution and meteorological elements with primary care visits at night due to asthma attack was studied. A case-crossover study was conducted in a primary care clinic in Himeji City, Japan. The subjects were 956 children aged 0-14 years who visited the clinic with an asthma attack between the hours of 9 p.m. and 6 a.m. Daily concentrations of particulate matter, ozone, nitrogen dioxide, and a number of meteorological elements were measured, and a conditional logistic regression model was used to estimate odds ratios (ORs) of primary care visits per unit increment of air pollutants or meteorological elements. The analyses took into consideration the effects of seasonality. Of the 956 children, 73 (7.6 %) were aged asthma attack at night in the spring or summer was found. An inverse relation between suspended particulate matter and primary care visits due to asthma attack was detected in the winter. ORs in the summer per degree increment in daily mean temperature was 1.31 [95 % confidential interval (CI) 1.09-1.56], and ORs in the autumn per hourly increment in daily hours of sunshine was 0.94 (95 % CI 0.90-0.99). The findings of our study fail to support any association between daily mean concentration of air pollutant and primary care visits at night. However, we did find evidence indicating that certain meteorological elements may be associated with primary care visits.

  9. Improving Awareness of Health Hazards Associated with Air Pollution in Primary School Children: Design and Test of Didactic Tools

    Science.gov (United States)

    Carducci, Annalaura; Casini, Beatrice; Donzelli, Gabriele; Verani, Marco; Bruni, Beatrice; Ceretti, Elisabetta; Zani, Claudia; Carraro, Elisabetta; Bonetta, Sara; Bagordo, Francesco; Grassi, Tiziana; Villarini, Milena; Bonizzoni, Silvia; Zagni, Licia; Gelatti, Umberto

    2016-01-01

    One of the objectives of the MAPEC-Life project is raising children's awareness on air quality and its health effects. To achieve this goal, we designed didactic tools for primary school students, including leaflets with more information for teachers, a cartoon, and three educational videogames. The tools were then tested with 266 children who…

  10. Experimental study on air ingress during a primary pipe rupture accident with a graphite reactor core simulator

    International Nuclear Information System (INIS)

    Takeda, Tetsuaki; Hishida, Makoto; Baba, Shinichi

    1991-11-01

    When a primary coolant pipe of a High Temperature Gas Cooled Reactor (HTGR) ruptures, helium gas in the reactor core blows out into the container, and the primary cooling system reduces the pressure. After the pressures are balanced between the reactor and the container, air is expected to enter into the reactor core from the breach. It seems to be probable that the graphite structures is oxidized by air. Hence, it is necessary to investigate the air ingress process and the behavior of the generating gases by the oxidation reactions. The previous experimental study is performed on the molecular diffusion and natural convection of the two component gas mixtures using a test model simulating simply the reactor. Objective of the study was to investigate the air ingress process during the early stage of the primary pipe rupture accident. However, since the model did not have any kind of graphite components, the reaction between graphite and oxygen was not simulated. The present model includes the reactor core and the high temperature plenum simulators made of graphite. The major results obtained in the present study are summarized in the followings: (1) The air ingress process with graphite oxidation reaction is similar to that without the reaction qualitatively. (2) When the reactor core simulator is maintained at low temperatures (lower than 450degC), the initiation time of the natural circulation of air is almost equal to that of the natural circulation of nitrogen. On the other hand, when the temperature of the reactor core simulator is high (more than 500degC), the initiation time of the natural circulation of air is earlier than that of nitrogen. (3) When the temperature of the reactor core simulator is higher than 600degC, oxygen is almost dissipated by the graphite structures. When the temperature of the reactor core simulator is below 700degC, carbon dioxide mainly is generated by the oxidation reactions. (author)

  11. Chemical pleurodesis for prolonged postoperative air leak in primary spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Cheng-Hung How

    2014-05-01

    Conclusion: Chemical pleurodesis using OK-432 or minocycline is safe and convenient for prolonged air leak after thoracoscopic treatment for PSP. Our experience suggested that OK-432 may be more effective than minocycline in reducing air leak.

  12. Local emission of primary air pollutants and its contribution to wet deposition and concentrations of aerosols and gases in ambient air in Japan

    Science.gov (United States)

    Aikawa, Masahide; Hiraki, Takatoshi; Tomoyose, Nobutaka; Ohizumi, Tsuyoshi; Noguchi, Izumi; Murano, Kentaro; Mukai, Hitoshi

    2013-11-01

    We studied wet deposition by precipitation and the concentrations of aerosols and gases in ambient air in relation to the primary air pollutants discharged from domestic areas. The concentrations of aerosols and gases were influenced by nearby emissions except for non-sea-salt SO, which is transported long distances. The area facing the Sea of Japan showed much larger wet deposition than other areas, although the domestic emissions of the primary air pollutants there were small and showed a peak in wet deposition from October to March, as distinct from April to September in other areas. We performed the correlation analyses between wet deposition of each component and the product of the concentrations of corresponding aerosols and gases in ambient air and the two-thirds power of the precipitation. From the results, following scavenging processes were suggested. • Sulfate and ammonium were scavenged in precipitation as particulate matter such as (NH4)2SO4 and NH4HSO4. • Nitrate was scavenged mainly in precipitation through gaseous HNO3. • Ammonium was complementarily scavenged in precipitation through aerosols such as (NH4)2SO4 and NH4HSO4 and through gaseous NH3.

  13. Cooperative observations of air showers in Tasmania looking for anisotropies in 1013 - 1014 eV primaries (COALA project)

    International Nuclear Information System (INIS)

    Fenton, A.G.; Fenton, K.B.; Humble, J.E.

    1981-01-01

    Observations of cosmic ray air showers (median primary energy: 5.10 13 eV) in Tasmania have been planned to start during 1981. The observations will be carried out through collaboration of the Hobart and Nagoya groups, in order to catch cosmic ray flows in a somewhat stereoscopic manner with simultaneous observations in the northern hemisphere (Mt. Norikura). The air shower array consists of 18 unit trays of 4 m 2 proportional counters deployed over an area of 20 m x 160 m. The shower frequency in a fundamental coincidence mode is expected to be about 16,000 events per hour

  14. 40 CFR Appendix I to Part 50 - Interpretation of the 8-Hour Primary and Secondary National Ambient Air Quality Standards for Ozone

    Science.gov (United States)

    2010-07-01

    ... Secondary National Ambient Air Quality Standards for Ozone 1. General. This appendix explains the data.... Primary and Secondary Ambient Air Quality Standards for Ozone. 2.1 Data Reporting and Handling Conventions... and Secondary National Ambient Air Quality Standards for Ozone I Appendix I to Part 50 Protection of...

  15. Investigating the Cherenkov light lateral distribution function for primary proton and iron nuclei in extensive air showers

    International Nuclear Information System (INIS)

    Al-Rubaiee, A.A.; Hashim, U.; Al-Douri, Y.

    2015-01-01

    The lateral distribution function (LDF) of Cherenkov radiation in extensive air showers (EAS) was simulated by CORSIKA program for the conditions of Yakutsk Cherenkov array at high energy range (10 13 -10 16 eV) for two primary particles (p and Fe) for different zenith angles. Using Breit-Wigner function for analyzing Cherenkov light LDF, a parameterization of Cherenkov light LDF was reconstructed by depending on CORSIKA simulation as a function of primary energy. The comparison between the estimated Cherenkov light LDF and the LDF that was measured on the Yakutsk EAS array gives the ability of particle identification that initiated the shower and determination of particle's energy around the knee region. The extrapolation of approximated Cherenkov light LDF for energies 20 and 30 PeV was obtained for primary particles (p and Fe)

  16. Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.

    Science.gov (United States)

    Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia

    2013-09-03

    Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (EU/m(3) and EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.

  17. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia Fiorini da

    2016-01-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  18. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools

    Directory of Open Access Journals (Sweden)

    Juliana P. Sá

    2017-05-01

    Full Text Available Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO2, CO, NO2, O3, CH2O, total volatile organic compounds (VOC, PM1, PM2.5, PM10, Total Suspended Particles (TSP and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO were found for PM2.5, PM10, CO2 and CH2O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE. In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO2. However, mitigation measures were not always sufficient to decrease the pollutants’ concentrations till values considered safe to protect human health.

  19. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools.

    Science.gov (United States)

    Sá, Juliana P; Branco, Pedro T B S; Alvim-Ferraz, Maria C M; Martins, Fernando G; Sousa, Sofia I V

    2017-05-31

    Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO₂, CO, NO₂, O₃, CH₂O, total volatile organic compounds (VOC), PM₁, PM 2.5 , PM 10 , Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM 2.5 , PM 10 , CO₂ and CH₂O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO₂. However, mitigation measures were not always sufficient to decrease the pollutants' concentrations till values considered safe to protect human health.

  20. Air pressure-induced iridocornea contact in a patient with primary angle closure observed with a dynamic Scheimpflug analyzer.

    Science.gov (United States)

    Kawashima, Rumi; Matsushita, Kenji; Fujimoto, Hisataka; Maeda, Naoyuki; Nishida, Kohji

    2015-01-01

    To report air pressure-induced corneal deformation and iridocornea contact in eyes with primary angle closure (PAC) during intraocular pressure (IOP) measurement performed using a novel noncontact tonometer. A single case report. We report a patient with bilateral angle closure. One eye had acute PAC and the other had PAC. The latter was evaluated by the movements of the cornea and iris during IOP measurement using a noncontact tonometer. During the examination, the corneal endothelium and the iris came into contact at the mid-peripheral pupillary area in the left eye with PAC during the corneal reaction to an air puff. In contrast, the corneal endothelium in the pupillary area did not come into contact with the iris. Although we observed only 1 case and there could be limitations in its interpretation, IOP measurements using a noncontact tonometer may create mechanical stress on the corneal endothelium in eyes with PAC with a very shallow anterior chamber.

  1. Diagnostic Air Quality Model Evaluation of Source-Specific Primary and Secondary Fine Particulate Carbon

    Science.gov (United States)

    Ambient measurements of 78 source-specific tracers of primary and secondary carbonaceous fine particulate matter collected at four midwestern United States locations over a full year (March 2004–February 2005) provided an unprecedented opportunity to diagnostically evaluate...

  2. Primary Aluminum Reduction Industry - National Emission Standards for Hazardous Air Pollutants (NESHAP)

    Science.gov (United States)

    National emission standards for each new or existing potline, paste production operation, and anode bake furnace associated with a primary aluminum reduction plant. Includes rule history, implementation information and additional resources.

  3. Starved air combustion-solidification/stabilization of primary chemical sludge from a tannery

    Energy Technology Data Exchange (ETDEWEB)

    Swarnalatha, S. [Department of Environmental Technology, Central Leather Research Institute, Adyar, Chennai-600 020, Tamil Nadu (India); Ramani, K. [Department of Environmental Technology, Central Leather Research Institute, Adyar, Chennai-600 020, Tamil Nadu (India); Karthi, A. Geetha [Department of Environmental Technology, Central Leather Research Institute, Adyar, Chennai-600 020, Tamil Nadu (India); Sekaran, G. [Department of Environmental Technology, Central Leather Research Institute, Adyar, Chennai-600 020, Tamil Nadu (India)]. E-mail: ganesansekaran@hotmail.com

    2006-09-01

    The high concentration of trivalent chromium along with organic/inorganic compounds in tannery sludge causes severe ground water contamination in the case of land disposal and chronic air pollution during incineration. In the present investigation, the sludge was subjected to flow-through column test to evaluate the concentration of leachable organics (tannin, COD and TOC) and heavy metal ions (Cr{sup 3+}, Fe{sup 2+}) present in it. The dried sludge was incinerated at 800 deg. C in an incinerator under starved oxygen supply (starved-air combustion) to prevent the conversion of Cr{sup 3+} to Cr{sup 6+}. The efficiency of starved air combustion was studied under different loading rates of sludge. The calcined sludge was solidified/stabilized using fly ash and Portland cement/gypsum. The solidified bricks were tested for unconfined compressive strength and heavy metal leaching. Unconfined compressive strength of the blocks was in the range of 83-156 kg/cm{sup 2}. The stabilization of chromium (III) in the cement gel matrix was confirmed with scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDX). Leachability studies on solidified bricks were carried out to determine the metal fixation and dissolved organic (as COD) concentration in the leachate.

  4. Association between traffic-related air pollution in schools and cognitive development in primary school children: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    Jordi Sunyer

    2015-03-01

    Full Text Available Air pollution is a suspected developmental neurotoxicant. Many schools are located in close proximity to busy roads, and traffic air pollution peaks when children are at school. We aimed to assess whether exposure of children in primary school to traffic-related air pollutants is associated with impaired cognitive development.We conducted a prospective study of children (n = 2,715, aged 7 to 10 y from 39 schools in Barcelona (Catalonia, Spain exposed to high and low traffic-related air pollution, paired by school socioeconomic index; children were tested four times (i.e., to assess the 12-mo developmental trajectories via computerized tests (n = 10,112. Chronic traffic air pollution (elemental carbon [EC], nitrogen dioxide [NO2], and ultrafine particle number [UFP; 10-700 nm] was measured twice during 1-wk campaigns both in the courtyard (outdoor and inside the classroom (indoor simultaneously in each school pair. Cognitive development was assessed with the n-back and the attentional network tests, in particular, working memory (two-back detectability, superior working memory (three-back detectability, and inattentiveness (hit reaction time standard error. Linear mixed effects models were adjusted for age, sex, maternal education, socioeconomic status, and air pollution exposure at home. Children from highly polluted schools had a smaller growth in cognitive development than children from the paired lowly polluted schools, both in crude and adjusted models (e.g., 7.4% [95% CI 5.6%-8.8%] versus 11.5% [95% CI 8.9%-12.5%] improvement in working memory, p = 0.0024. Cogently, children attending schools with higher levels of EC, NO2, and UFP both indoors and outdoors experienced substantially smaller growth in all the cognitive measurements; for example, a change from the first to the fourth quartile in indoor EC reduced the gain in working memory by 13.0% (95% CI 4.2%-23.1%. Residual confounding for social class could not be discarded completely

  5. Association between traffic-related air pollution in schools and cognitive development in primary school children: a prospective cohort study.

    Science.gov (United States)

    Sunyer, Jordi; Esnaola, Mikel; Alvarez-Pedrerol, Mar; Forns, Joan; Rivas, Ioar; López-Vicente, Mònica; Suades-González, Elisabet; Foraster, Maria; Garcia-Esteban, Raquel; Basagaña, Xavier; Viana, Mar; Cirach, Marta; Moreno, Teresa; Alastuey, Andrés; Sebastian-Galles, Núria; Nieuwenhuijsen, Mark; Querol, Xavier

    2015-03-01

    Air pollution is a suspected developmental neurotoxicant. Many schools are located in close proximity to busy roads, and traffic air pollution peaks when children are at school. We aimed to assess whether exposure of children in primary school to traffic-related air pollutants is associated with impaired cognitive development. We conducted a prospective study of children (n = 2,715, aged 7 to 10 y) from 39 schools in Barcelona (Catalonia, Spain) exposed to high and low traffic-related air pollution, paired by school socioeconomic index; children were tested four times (i.e., to assess the 12-mo developmental trajectories) via computerized tests (n = 10,112). Chronic traffic air pollution (elemental carbon [EC], nitrogen dioxide [NO2], and ultrafine particle number [UFP; 10-700 nm]) was measured twice during 1-wk campaigns both in the courtyard (outdoor) and inside the classroom (indoor) simultaneously in each school pair. Cognitive development was assessed with the n-back and the attentional network tests, in particular, working memory (two-back detectability), superior working memory (three-back detectability), and inattentiveness (hit reaction time standard error). Linear mixed effects models were adjusted for age, sex, maternal education, socioeconomic status, and air pollution exposure at home. Children from highly polluted schools had a smaller growth in cognitive development than children from the paired lowly polluted schools, both in crude and adjusted models (e.g., 7.4% [95% CI 5.6%-8.8%] versus 11.5% [95% CI 8.9%-12.5%] improvement in working memory, p = 0.0024). Cogently, children attending schools with higher levels of EC, NO2, and UFP both indoors and outdoors experienced substantially smaller growth in all the cognitive measurements; for example, a change from the first to the fourth quartile in indoor EC reduced the gain in working memory by 13.0% (95% CI 4.2%-23.1%). Residual confounding for social class could not be discarded completely; however

  6. 76 FR 76259 - National Emissions Standards for Hazardous Air Pollutants: Primary Aluminum Reduction Plants

    Science.gov (United States)

    2011-12-06

    ... Emissions From Maleic Anhydride Plants, Ethylbenzene/Styrene Plants, Benzene Storage Vessels, Benzene...). The rule is applicable to facilities with affected sources associated with the production of aluminum... are subject to the requirements of this NESHAP: 14 primary aluminum production plants and one carbon...

  7. Radon measurements in air in waterworks and indoor swimming pools - a primary mapping project

    International Nuclear Information System (INIS)

    Marinko, J.; Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    In 2001 the Swedish Work Environment Authority asked five regional offices around the country; Falun, Malmoe, Vaexjoe, Umeaa and Oerebro, to measure radon in air in workplaces where water was likely to enhance radon levels indoors. Track etch detectors were used and placed in workplaces according to the SSI measurement protocol for determining the annual average radon concentration in homes. Rooms that are frequently used by employees were measured. The detectors were exposed between 1 to 3 months. 225 detectors were used in the project and analysed at the same laboratory. The results showed that the radon concentration in waterworks often is high. Measurements were made in 60 waterworks. Levels exceeding 1000 Bq/m 3 were found in 49 of them and levels exceeding 4000 Bq/m 3 were found in 21 waterworks. The variation between waterworks may be a result of the radon concentration in the raw water, the amount of radon gas escaping to the air when water is treated, the air exchange rate in the building and where the detectors were deployed. Measurements were made in 28 indoor swimming baths. The maximum level was 290 Bq/m 3 , but most concentrations were between 30 to 70 Bq/m 3 . The conclusion is that high radon levels do not seem to be a problem in indoor swimming baths. Maybe this is due to good ventilation or the fact that water often has been treated for radon before it is used in swimming pools. The results from measurement in food industries such as breweries showed no extreme radon levels except for a fish farm where levels over 1000 Bq/m 3 were measured in the farming room and 790 Bq/m 3 in the office. The radon concentrations in laundries were relatively low, between 30 and 170 Bq/m 3

  8. Direct numerical simulations of the ignition of lean primary reference fuel/air mixtures with temperature inhomogeneities

    KAUST Repository

    Luong, Minhbau

    2013-10-01

    The effects of fuel composition, thermal stratification, and turbulence on the ignition of lean homogeneous primary reference fuel (PRF)/air mixtures under the conditions of constant volume and elevated pressure are investigated by direct numerical simulations (DNSs) with a new 116-species reduced kinetic mechanism. Two-dimensional DNSs were performed in a fixed volume with a two-dimensional isotropic velocity spectrum and temperature fluctuations superimposed on the initial scalar fields with different fuel compositions to elucidate the influence of variations in the initial temperature fluctuation and turbulence intensity on the ignition of three different lean PRF/air mixtures. In general, it was found that the mean heat release rate increases slowly and the overall combustion occurs fast with increasing thermal stratification regardless of the fuel composition under elevated pressure and temperature conditions. In addition, the effect of the fuel composition on the ignition characteristics of PRF/air mixtures was found to vanish with increasing thermal stratification. Chemical explosive mode (CEM), displacement speed, and Damköhler number analyses revealed that the high degree of thermal stratification induces deflagration rather than spontaneous ignition at the reaction fronts, rendering the mean heat release rate more distributed over time subsequent to thermal runaway occurring at the highest temperature regions in the domain. These analyses also revealed that the vanishing of the fuel effect under the high degree of thermal stratification is caused by the nearly identical propagation characteristics of deflagrations of different PRF/air mixtures. It was also found that high intensity and short-timescale turbulence can effectively homogenize mixtures such that the overall ignition is apt to occur by spontaneous ignition. These results suggest that large thermal stratification leads to smooth operation of homogeneous charge compression-ignition (HCCI

  9. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  10. Primary energy savings in desiccant and evaporative cooling-assisted 100% outdoor air system combined with a fuel cell

    International Nuclear Information System (INIS)

    Kim, Min-Hwi; Dong, Hae-Won; Park, Joon-Young; Jeong, Jae-Weon

    2016-01-01

    Highlights: • A LD-IDECOAS integrated with a PEMFC was proposed. • A pilot system was installed and tested during cooling operation. • The proposed system powered by the PEMFC saved 21% of the primary energy consumption during cooling. - Abstract: The main purpose of this study involved investigating the primary energy saving potential of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) integrated with a proton exchange membrane fuel cell (PEMFC). During the cooling season, the heat produced by the PEMFC was used to regenerate a weak desiccant solution, and the electricity generated was used to operate the LD-IDECOAS. A pilot LD-IDECOAS powered by a PEMFC was installed and operated in an office space to experimentally verify the annual operating energy savings of the proposed system. The findings indicated that the heat reclaimed from the PEMFC saved 42% of the desiccant solution regenerating energy when compared to that in the case of a conventional gas-fired water heater. The results also suggested that the LD-IDECOAS combined with a PEMFC consumed 21% less primary energy when compared with that of a system powered by grid electricity and a conventional gas-fired water heater.

  11. Preliminary study of the primary nozzle position of a supersonic air ejector with a constant-area mixing chamber

    Directory of Open Access Journals (Sweden)

    Kracik Jan

    2017-01-01

    Full Text Available This work aims at investigating the primary nozzle position in a proposed supersonic air ejector device. The ejector is primarily made up of a supersonic primary nozzle, which is located in the axis of the ejector, a suction chamber or secondary stream inlet, a mixing chamber and a diffuser. The ejector design allows to translate the primary nozzle in the axis direction and fix it in a chosen distance from the beginning of the mixing chamber and hence influence the secondary mass flow rate. In a limit case, it is possible to set the nozzle to such a position where no secondary flow occurs. If we ignore the case where no secondary flow occurs, five different nozzle distances have been investigated in this paper. Some cases seem to be alike and there are no significant dissimilarities between them. Courses of relative back-pressure ratio are carried out against the entrainment ratio and transition between on-design and off-design regimes is determined. Measurements of the mixed flow based on the standard ISO 5167 are performed by means of orifice plate method. In addition, a comparison between experiments and simulations performed by Ansys Fluent software is presented in order to indicate further improvements to the numerical model.

  12. Ambient air pollution and primary liver cancer incidence in four European cohorts within the ESCAPE project

    DEFF Research Database (Denmark)

    Pedersen, Marie; Andersen, Zorana J.; Stafoggia, Massimo

    2017-01-01

    . Methods: We obtained data from four cohorts with enrolment during 1985–2005 in Denmark, Austria and Italy. Exposure to nitrogen oxides (NO2 and NOX), particulate matter (PM) with diameter of less than 10 µm (PM10), less than 2.5 µm (PM2.5), between 2.5 and 10 µm (PM2.5–10) and PM2.5 absorbance (soot......-analyses to estimate summary hazard ratios (HRs) and 95% confidence intervals (CIs). Results: Out of 174,770 included participants, 279 liver cancer cases were diagnosed during a mean follow-up of 17 years. In each cohort, HRs above one were observed for all exposures with exception of PM2.5 absorbance and traffic...... in PM2.5. Conclusions: The results provide suggestive evidence that ambient air pollution may increase the risk of liver cancer. Confidence intervals for associations with NO2 and NOX were narrower than for the other exposures....

  13. Indoor Air Quality and Thermal Conditions in a Primary School with a Green Roof System

    Directory of Open Access Journals (Sweden)

    Nikolaos Barmparesos

    2018-02-01

    Full Text Available This paper presents experimental results from a typical school building in Athens, equipped partly with a green roof system (GRS. Environmental monitoring took place in six classrooms located both under the concrete roof and the GRS sectors as well as in the immediate external environment during the warm and cold periods of a school year. Daily measurements of pollutants CO2, TVOCs (Total Volatile Organic Compound, PM1, PM2.5, and PM10 were performed in selected classes. Moreover, indoor ambient temperature (T and relative humidity (RH measurements were implemented in order to estimate the absolute humidity (AH and assess the indoor environmental conditions. The results highlight that during summer, the GRS reduces temperature in a classroom on the top floor by about 2.8 °C, in comparison with the respective classroom under the concrete roof and that AH remained relatively stable for both classrooms. Amid winter, a reverse behavior occurs only for temperature. Moreover, air exchange rates (AER were calculated by using the CO2 decay method for all of the classrooms. The results demonstrated insufficient ventilation for all experimental sights. Finally, concentrations of PM1, PM2.5 and PM10, were found to be relatively decreased, with average values of 0.79, 3.39, and 27.80 μg m−3. Levels of CO2 and TVOCs were elevated during class hours ranging from 469 to 779 ppm and from 6.63 ppm to 13.33 ppm, respectively, but generally within the respective limits of exposure. The examination of the indoor/outdoor (I/O ratio of air pollutants, demonstrated that the outdoor meteorology affects only PM1 and PM2.5, as PM10 and TVOCs are strongly affected by internal sources and the activities of pupils.

  14. FFTF primary heat transport system heating, ventilating and air conditioning system experience

    International Nuclear Information System (INIS)

    Umek, A.M.; Hicks, D.F.; Schweiger, D.L.

    1981-01-01

    FFTF cools its primary/in-containment sodium equipment cells by means of a forced nitrogen cooling system which exchanges heat with a water-glycol system. The nitrogen cooling system is also used to maintain an inert gas atmosphere in the cells containing sodium equipment. Sodium Piping and Components have installed electrical resistance heaters to maintain a minimum sodium temperature and stainless steel jacketed mineral insulation to reduce heat loss. Design features and test results of a comprehensive redesign of the HVAC and insulation system required to support long-term nuclear operations are discussed

  15. Radon in indoor air of primary schools: determinant factors, their variability and effective dose.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João; Moreira, André; de Oliveira Fernandes, Eduardo; Pereira, Alcides

    2016-04-01

    Radon is a radioactive gas, abundant in granitic areas, such as in the city of Porto at the north-east of Portugal. This gas is a recognized carcinogenic agent, being appointed by the World Health Organization as the leading cause of lung cancer after smoking. The aim of this preliminary survey was to determine indoor radon concentrations in public primary schools, to analyse the main factors influencing their indoor concentration levels and to estimate the effective dose in students and teachers in primary schools. Radon concentrations were measured in 45 classrooms from 13 public primary schools located in Porto, using CR-39 passive radon detectors for about 2-month period. In all schools, radon concentrations ranged from 56 to 889 Bq/m(3) (mean = 197 Bq/m(3)). The results showed that the limit of 100 Bq/m(3) established by WHO IAQ guidelines was exceeded in 92 % of the measurements, as well as 8 % of the measurements exceeded the limit of 400 Bq/m(3) established by the national legislation. Moreover, the mean annual effective dose was calculated as 1.25 mSv/y (ranging between 0.58 and 3.07 mSv/y), which is below the action level (3-10 mSv). The considerable variability of radon concentration observed between and within floors indicates a need to monitor concentrations in several rooms for each floor. A single radon detector for each room can be used, provided that the measurement error is considerably lower than variability of radon concentration between rooms. The results of the present survey will provide useful baseline data for adopting safety measures and dealing effectively with radiation emergencies. In particular, radon remediation techniques should be used in buildings located in the highest radon risk areas of Portugal. The results obtained in the current study concerning radon levels and their variations will be useful to optimize the design of future research surveys.

  16. Primary design and operation analysis of the ITER air transfer system

    International Nuclear Information System (INIS)

    Wang Haitian; Li Ge; Qin Shijun

    2010-01-01

    Air transfer system (ATS) is a remote handling transfer, which can work in the nuclear radiation environment and can be driven by the electricity fully. Its motion power is provided by several servo motors. The remote control technology of ATS, which is China taking part in the plan of international Tokamak experimental reactor (ITER) and grasping this technology, is one of key technologies of ITER. The remote handling technology can lay the foundation for developing demonstration nuclear fusion power plant in China on self-reliance. Because there is gamma irradiation and hazard material in these ITER parts, all required maintenance of port plugs and inner components are been transmitted by ATS. The pick-up or drop-off these components are completed by means of a remotely controlled TCS system between the Vacuum Vessel and the Hot Cell through the bridge-gallery. Tokamak building includes three floors, including upper port, equatorial port and lower port, linked by a lift. According to each port level configuration and safety requirement, the radius of curvature with ATS trajectory is optimized, and a trajectory of each level is determined by positioned guidance beacons. At last, the results of computer aided design (CAD) show single trajectory guidance of ATS in each level is available. (authors)

  17. Binding CO2 from Air by a Bulky Organometallic Cation Containing Primary Amines.

    Science.gov (United States)

    Luo, Yang-Hui; Chen, Chen; Hong, Dan-Li; He, Xiao-Tong; Wang, Jing-Wen; Ding, Ting; Wang, Bo-Jun; Sun, Bai-Wang

    2018-03-21

    The organometallic cation 1 (Fe(bipy-NH 2 ) 3 2+ , bipy-NH 2 = 4,4'-diamino-2,2'-bipyridine), which was constructed in situ in solution, can bind CO 2 from air effectively with a stoichiometric ratio of 1:4 (1/CO 2 ), through the formation of "H-bonded CO 2 " species: [CO 2 -OH-CO 2 ] - and [CO 2 -CO 2 -OH] - . These two species, along with the captured individual CO 2 molecules, connected 1 into a novel 3D (three-dimensional) architecture, that was crystal 1·2(OH - )·4(CO 2 ). The adsorption isotherms, recycling investigations, and the heat capacity of 1 have been investigated; the results revealed that the organometallic cation 1 can be recycled at least 10 times for the real-world CO 2 capture applications. The strategies presented here may provide new hints for the development of new alkanolamine-related absorbents or technologies for CO 2 capture and sequestration.

  18. Extensive air showers accompanied by gamma-families and fraction of protons in the primary cosmic rays

    International Nuclear Information System (INIS)

    Hamayasu, C.; Saito, To.; Sakata, M.

    1987-01-01

    Experimental data of EAS accompanied by gamma-families with a total energy greater than 10 TeV are taken at Mt. Norikura in 1980 -- 1981 and in 1985. An EX (emulsion and/or x-ray film) chamber is used, which consists six sensitive layers and iron plates as the absorber. The iron absorber chamber can detect more hadron origin cascades than a lead absorber chamber for the same chamber thickness in radiation length, though disadvantageous for separation of gamma-ray origin cascades from hadron origin ones. Analysis is made of the single gamma-ray energy spectrum, integral spectrum of total energies of gamma-families, zenith angle distributions of gamma-families, the scatter plot of EAS size - ΣE γ,H correlation, arrival zenith angle distribution of general EAS, and depth dependence of absolute vertical intensities of EAS. The data obtained are compared by the Monte Carlo simulation technique with a moderate rising cross section proportional to the collision energy in the form E 0.04 for p-air nucleus collisions. The absolute intensity of size spectrum of such EAS is strongly affected by the fraction of primary protonsin the 10 15 -- 10 16 eV region. The experimental size spectrum agrees with the simulated spectrum for the p-poor (up to 15 %) primary composition but it disagrees with the p-rich (up to 40 %) one in the first half, at least, of this energy region. (Nogami, K.)

  19. A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography

    International Nuclear Information System (INIS)

    Kharrati, Hedi

    2005-01-01

    In this study, a new approach has been introduced for derivation of the effective dose from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to the effective dose for the mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium, National Institute of Standards and Technology, and International Atomic Energy Agency laboratories. The results show that, in all cases, the effective dose in mammography energy range is less than 25% of the incident air kerma for the primary and the scatter radiations and does not exceed 75% for the leakage radiation

  20. Construction of a laboratory for the implantation of primary standardization of the magnitude kerma in the air for the X-ray beams used in mammography

    International Nuclear Information System (INIS)

    Cardozo, W.L.; Magalhes, L.A.A.M.F.; Peixoto, J.G.P.

    2009-01-01

    Aiming to diminish the uncertainty in each phase of the metrological chain, and the uncertainty in dosimetry processed at the X-ray beam applied in the mammography, is necessary that the LNMRI/IRD to develop a reference primary standard for the absolute form to the magnitude kerma in the air

  1. Mixer Assembly for a Gas Turbine Engine

    Science.gov (United States)

    Dai, Zhongtao (Inventor); Cohen, Jeffrey M. (Inventor); Fotache, Catalin G. (Inventor); Smith, Lance L. (Inventor); Hautman, Donald J. (Inventor)

    2018-01-01

    A mixer assembly for a gas turbine engine is provided, including a main mixer with fuel injection holes located between at least one radial swirler and at least one axial swirler, wherein the fuel injected into the main mixer is atomized and dispersed by the air flowing through the radial swirler and the axial swirler.

  2. Monitoring and Modelling the Trends of Primary and Secondary Air Pollution Precursors: The Case of the State of Kuwait

    Directory of Open Access Journals (Sweden)

    S. M. Al-Salem

    2010-01-01

    Full Text Available Since the beginning of the industrial revolution, processes of different scales have contributed greatly to the pollution and waste load on the environment. More specifically, airborne pollutants associated with chemical processes have contributed greatly on the ecosystem and populations health. In this communication, we review recent activities and trends of primary and secondary air pollutants in the state of Kuwait, a country associated with petroleum, petrochemical, and other industrial pollution. Trends of pollutants and impact on human health have been studied and categorized based on recent literature. More attention was paid to areas known to researchers as either precursor sensitive (i.e., nitrogen oxides (NOx, volatile organic compounds (VOCs or adjacent to upstream- or downstream-related activities. Environmental monitoring and modelling techniques relevant to this study are also reviewed. Two case studies that link recent data with models associated with industrial sectors are also demonstrated, focusing mainly on chemical mass balance (CMB and Gaussian line source modelling. It is concluded that a number of the monitoring stations and regulations placed by the Kuwait Environment Public Authority (KUEPA need up-to-date revisions and better network placement, in agreement with previous findings.

  3. 40 CFR Appendix S to Part 50 - Interpretation of the Primary National Ambient Air Quality Standards for Oxides of Nitrogen...

    Science.gov (United States)

    2010-07-01

    ... Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) S Appendix S to Part 50 Protection... National Ambient Air Quality Standards for Oxides of Nitrogen (Nitrogen Dioxide) 1. General (a) This... national ambient air quality standards for oxides of nitrogen as measured by nitrogen dioxide (“NO2 NAAQS...

  4. Unprecedented selective aminolysis: Aminopropyl phosphine as a building block for a new family of air stable mono-, bis-, and tris-primary phosphines

    Energy Technology Data Exchange (ETDEWEB)

    Prabhu, K.R.; Pillarsetty, N.; Gali, H.; Katti, K.V.

    2000-02-23

    A serious impediment to using primary and secondary phosphines as general-purpose reagents to develop new chemistry is associated with their unpleasant pyrophoric nature and extreme hydrolytic, thermal, and oxidative instabilities. In particular, primary phosphines with ``user friendly'' properties (e.g., good oxidative/thermal stability, low volatility) would be extremely important not only from the synthetic point of view but also for potential application (e.g., in dendrimers formation). As part of ongoing research on the fundamental main group and organic chemistry of functionalized phosphorus compounds, the authors report, herein, unprecedented selectivity in the reaction of 3-aminopropyl primary phosphine 3, with the methyl ester in the presence of free acid, amide, and thiol to produce air stable amide, carboxylate, and thiol functionalized primary phosphines.

  5. GREX/COVER-PLASTEX: an experiment to analyze the space-time structure of extensive air showers produced by primary cosmic rays of 1015 eV

    International Nuclear Information System (INIS)

    Agnetta, G.; Ambrosio, M.; Beaman, J.; Barbarino, G.C.; Biondo, B.; Catalano, O.; Colesanti, L.; Dali, G.; Guarino, F.; Lauro, A.; Lloyd-Evans, J.; Mangano, A.; Popova, L.; Watson, A.A.

    1995-01-01

    A novel experimental installation is described in which the traditional method of detecting extensive air showers with scintillation counters is significantly extended by the addition of limited streamer tube hodoscopes (LST) and layers of resistive plate counters (RPC). Runs with the scintillator array, GREX, at Haverah Park have demonstrated the power of the LST hodoscopes to determine the direction of arrival of muons, electrons and photons in air showers while the RPC system permits the relative arrival time of individual particles and the temporal thickness and structure of the shower disc to be obtained. The potential of these technical advances for studying the longitudinal profile of air showers produced by primaries of about 1000 TeV is briefly discussed. First measurements of thickness and time profile of EAS front are also reported. (orig.)

  6. Determination of average conversion coefficients between kerma in air and H⁎(10) using primary and secondary X-ray beams and transmitted in the diagnostic radiology energy range

    International Nuclear Information System (INIS)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Costa, Paulo R.

    2016-01-01

    Brazilian regulation establishes 1.14 Sv/Gy as unique conversion coefficient to convert air-kerma into the operational quantity ambient dose equivalent H⁎(10) disregarding its beam quality dependence. The present study computed mean conversion coefficients from primary, secondary and transmitted X-ray beams through barite mortar plates used in shielding of dedicated chest radiographic facilities in order to improve the current assessment of H⁎(10). To compute the mean conversion coefficients, the weighting of conversion coefficients corresponding to monoenergetic beams with the spectrum energy distribution in terms of air-kerma was considered. The maximum difference between the obtained conversion coefficients and the constant value recommended in national regulation is 53.4%. The conclusion based on these results is that a constant coefficient is not adequate for deriving the H⁎(10) from air-kerma measurements. (author)

  7. Evaluation of chemical transport model predictions of primary organic aerosol for air masses classified by particle-component-based factor analysis

    OpenAIRE

    C. A. Stroud; M. D. Moran; P. A. Makar; S. Gong; W. Gong; J. Zhang; J. G. Slowik; J. P. D. Abbatt; G. Lu; J. R. Brook; C. Mihele; Q. Li; D. Sills; K. B. Strawbridge; M. L. McGuire

    2012-01-01

    Observations from the 2007 Border Air Quality and Meteorology Study (BAQS-Met 2007) in Southern Ontario, Canada, were used to evaluate predictions of primary organic aerosol (POA) and two other carbonaceous species, black carbon (BC) and carbon monoxide (CO), made for this summertime period by Environment Canada's AURAMS regional chemical transport model. Particle component-based factor analysis was applied to aerosol mass spectrometer measurements made at one urban site (Windsor, ON) and two...

  8. Arrival time distributions of electrons in air showers with primary energies above 10 (18)eV observed at 900m above sea level

    Science.gov (United States)

    Kakimoto, F.; Tsuchimoto, I.; Enoki, T.; Suga, K.; Nishi, K.

    1985-01-01

    Detection of air showers with primary energies above 10 to the 19th power eV with sufficient statistics is extremely important in an astrophysical aspect related to the Greisen cut off and the origin of such high energy cosmic rays. Recently, a method is proposed to observe such giant air showers by measuring the arrival time distributions of air-shower particles at large core distances with a mini array. Experiments to measure the arrival time distributions of muons were started in 1981 and those of electrons in early 1983 in the Akeno air-shower array (930 gcm cm squared atmospheric depth, 900m above sea level). During the time of observation, the detection area of the Akeno array was expanded from 1 sq km to sq km in 1982 and to 20 sq km in 1984. Now the arrival time distribution of electrons and muons can be measured for showers with primary energies above 1019eV at large core distances.

  9. Life cycle air emissions impacts and ownership costs of light-duty vehicles using natural gas as a primary energy source.

    Science.gov (United States)

    Luk, Jason M; Saville, Bradley A; MacLean, Heather L

    2015-04-21

    This paper aims to comprehensively distinguish among the merits of different vehicles using a common primary energy source. In this study, we consider compressed natural gas (CNG) use directly in conventional vehicles (CV) and hybrid electric vehicles (HEV), and natural gas-derived electricity (NG-e) use in plug-in battery electric vehicles (BEV). This study evaluates the incremental life cycle air emissions (climate change and human health) impacts and life cycle ownership costs of non-plug-in (CV and HEV) and plug-in light-duty vehicles. Replacing a gasoline CV with a CNG CV, or a CNG CV with a CNG HEV, can provide life cycle air emissions impact benefits without increasing ownership costs; however, the NG-e BEV will likely increase costs (90% confidence interval: $1000 to $31 000 incremental cost per vehicle lifetime). Furthermore, eliminating HEV tailpipe emissions via plug-in vehicles has an insignificant incremental benefit, due to high uncertainties, with emissions cost benefits between -$1000 and $2000. Vehicle criteria air contaminants are a relatively minor contributor to life cycle air emissions impacts because of strict vehicle emissions standards. Therefore, policies should focus on adoption of plug-in vehicles in nonattainment regions, because CNG vehicles are likely more cost-effective at providing overall life cycle air emissions impact benefits.

  10. Study on air ingress during an early stage of a primary-pipe rupture accident of a high-temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Hishida, M.; Takeda, T.

    1991-01-01

    A primary-pipe rupture accident is one of the design-based accidents of the HTTR. As the first step of our final goal of predicting the multicomponent gas flow in a reactor during the early stages of the accident, the present paper aims at studying experimentally and analytically, the basic features of air ingress and gas transportation by transient molecular diffusion and the transient natural convection of a two-component gas mixture. The present paper comprises two main parts. The first part deals with analytical and experimental studies on N 2 ingress (corresponding to air ingress) and gas transportation by molecular diffusion and the one-dimensional natural convection of an He-N 2 two-component gas mixture in a reverse-U-shaped tube. Analytical and experimental results are discussed on the N 2 mole fraction change with time after the simulated pipe rupture and on the initation time of the natural circulation of pure N 2 . The second part deals with a preliminary simulation test of air ingress during the early stages of the accident. The test is performed with a very simple model of the reactor. The experimental results are discussed on the change in mole fraction of air with time and on the initiation time of the natural circulation of pure air. (orig.)

  11. Swozzle based burner tube premixer including inlet air conditioner for low emissions combustion

    Science.gov (United States)

    Tuthill, Richard Sterling; Bechtel, II, William Theodore; Benoit, Jeffrey Arthur; Black, Stephen Hugh; Bland, Robert James; DeLeonardo, Guy Wayne; Meyer, Stefan Martin; Taura, Joseph Charles; Battaglioli, John Luigi

    2002-01-01

    A burner for use in a combustion system of a heavy-duty industrial gas turbine includes a fuel/air premixer having an air inlet, a fuel inlet, and an annular mixing passage. The fuel/air premixer mixes fuel and air into a uniform mixture for injection into a combustor reaction zone. The burner also includes an inlet flow conditioner disposed at the air inlet of the fuel/air premixer for controlling a radial and circumferential distribution of incoming air. The pattern of perforations in the inlet flow conditioner is designed such that a uniform air flow distribution is produced at the swirler inlet annulus in both the radial and circumference directions. The premixer includes a swozzle assembly having a series of preferably air foil shaped turning vanes that impart swirl to the airflow entering via the inlet flow conditioner. Each air foil contains internal fuel flow passages that introduce natural gas fuel into the air stream via fuel metering holes that pass through the walls of the air foil shaped turning vanes. By injecting fuel in this manner, an aerodynamically clean flow field is maintained throughout the premixer. By injecting fuel via two separate passages, the fuel/air mixture strength distribution can be controlled in the radial direction to obtain optimum radial concentration profiles for control of emissions, lean blow outs, and combustion driven dynamic pressure activity as machine and combustor load are varied.

  12. A conversion method of air-kerma from the primary, scatter and leakage radiations to ambient dose equivalent for calculating the mamography x-ray shielding barrier

    International Nuclear Information System (INIS)

    Kharrati, H.

    2005-01-01

    The primary, scatter, and leakage doses(in Gy), which constitute the data base for calculating shielding requirements for x-ray facilities, are often converted to the equivalent dose (in sievert) by using a constant of conversion of 1.145Sv/Gy. This constant is used for diagnostic radiology as well as for mammography spectra, and is derived by considering an exposure of 1 R corresponds to an air kerma of 8.73 m Gy, which renders by tradition an equivalent dose of 10 mSv. However, this conversion does not take into account the energy dependence of the conversion coefficients relating air kerma to the equivalent dose as described in ICRU report. Moreover, current radiation protection standards propose the use of the quantity ambient dose equivalent in order to qualify the efficiently of given radiation shielding. Therefore, in this study, a new approach has been introduced for derivation ambient dose equivalent from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to ambient dose equivalent for mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium (NMi), National Institute of Standards and Technology (NIST), and International Atomic Energy Agency (AIEA) laboratories. The calculation has been performed by the means of two methods which show a maximum deviation less than 10%2 for the primary, scatter, and leakage radiations. The results show that the conversion coefficients vary from 0.242 Sv/ Gy to 0.692 Sv/Gy with an average value of 0.436 Sv/Gy for the primary and the scatter radiations, and form 0.156 Sv/Gy to 1.329 Sv/Gy with an average value of 0.98 Sv/Gy for the leakage radiation. Simpkin et al. using an empirical approach propose a conversion value of 0.50 Sv/Gy for the mammography x-ray spectra. This value approximately coincides with the average conversion value of 0.436 Sv/Gy obtained in this work for

  13. Association between PM2.5 and primary care visits due to asthma attack in Japan: relation to Beijing's air pollution episode in January 2013.

    Science.gov (United States)

    Yamazaki, Shin; Shima, Masayuki; Yoda, Yoshiko; Oka, Katsumi; Kurosaka, Fumitake; Shimizu, Shigeta; Takahashi, Hironobu; Nakatani, Yuji; Nishikawa, Jittoku; Fujiwara, Katsuhiko; Mizumori, Yasuyuki; Mogami, Akira; Yamada, Taku; Yamamoto, Nobuharu

    2014-03-01

    In January 2013, extremely high concentrations of fine particles (PM2.5) were observed around Beijing, China. In Japan, the health effects of transboundary air pollution have been a matter of concern. We examined the association between the levels of outdoor PM2.5 and other air pollutants with primary care visits (PCVs) at night due to asthma attack in Himeji City, western Japan. A case-crossover study was conducted in a primary care clinic in Himeji City, Japan, involving 112 subjects aged 0-80 years who visited the clinic due to an asthma attack between 9 p.m. and 6 a.m. during the period January-March, 2013. Daily concentrations of particulate matter, ozone, nitrogen dioxide, and some meteorological elements were measured, and a conditional logistic regression model was used to estimate the odds ratios (OR) of PCVs per unit increment in air pollutants or meteorological elements. Of the 112 subjects, 76 (68 %) were aged asthma attack at night. A positive relation between ozone and PCVs due to asthma attack was detected. The OR per 10 ppb increment in daily mean ozone the day before the visit was 2.31 (95 % confidence interval 1.16-4.61). These findings do not support an association between daily mean concentration of PM2.5 and PCVs at night. However, we did find evidence suggesting that ozone is associated with PCVs.

  14. The cosmic ray primary composition between $10^{15}$ and $10^{16}$ ev from Extensive Air Showers electromagnetic and TeV muon data

    CERN Document Server

    Aglietta, M; Ambrosio, M; Antolini, R; Antonioli, P; Arneodo, F; Baldini, A; Barbarino, G C; Barish, B C; Battistoni, G; Becherini, Y; Bellotti, R; Bemporad, C; Bergamasco, L; Bernardini, P; Bertaina, M; Bilokon, H; Bower, C; Brigida, M; Bussino, S; Cafagna, F; Calicchio, M; Campana, D; Carboni, M; Caruso, R; Castagnoli, C; Castellina, A; Cecchini, S; Cei, F; Chiarella, V; Chiavassa, A; Choudhary, B C; Cini, G; Coutu, S; Cozzi, M; D'Ettorre-Piazzoli, B; De Cataldo, G; De Marzo, C; De Mitri, I; De Vincenzi, M; Dekhissi, H; Derkaoui, J; Di Credico, A; Di Sciascio, G; Erriquez, O; Favuzzi, C; Forti, C; Fulgione, W; Fusco, P; Galeotti, P; Ghia, P L; Giacomelli, G; Giannini, G; Giglietto, N; Giorgini, M; Grassi, M; Grillo, A; Guarino, F; Gustavino, C; Habig, A; Hanson, K; Heinz, R; Iacovacci, M; Iarocci, E; Katsavounidis, E; Katsavounidis, I; Kearns, E; Kim, H; Kyriazopoulou, S; Lamanna, E; Lane, C; Levin, D S; Lipari, P; Longley, N P; Longo, M J; Loparco, F; Maaroufi, F; Mancarella, G; Mandrioli, G; Mannocchi, G; Margiotta, A; Marini, A; Martello, D; Marzari-Chiesa, A; Mazziotta, M N; Michael, D G; Monacelli, P; Montaruli, T; Monteno, M; Morello, C; Mufson, S; Musser, J; Navarra, G; Nicolò, D; Nolty, R; Orth, C; Osteria, G; Palamara, O; Patera, V; Patrizii, L; Pazzi, R; Peck, C W; Perrone, L; Petrera, S; Popa, V; Rainó, A; Reynoldson, J; Ronga, F; Saavedra, O; Satriano, C; Scapparone, E; Scholberg, K; Sciubba, A; Serra, P; Sioli, M; Sirri, G; Sitta, M; Spinelli, P; Spinetti, M; Spurio, M; Stamerra, A; Steinberg, R; Stone, J L; Sulak, L R; Surdo, A; Tarle, G; Togo, V; Trinchero, G C; Vakili, M; Valchierotti, S; Vallania, P; Vernetto, S; Vigorito, C; Walter, C W; Webb, R; 10.1016/j.astropartphys.2003.10.004

    2004-01-01

    The cosmic ray primary composition in the energy range between 10/sup 15/ and 10/sup 16/ eV, i.e., around the "knee" of the primary spectrum, has been studied through the combined measurements of the EAS-TOP air shower array (2005 m a.s.l., 10/sup 5/ m/sup 2/ collecting area) and the MACRO underground detector (963 m a.s.l., 3100 m w.e. of minimum rock overburden, 920 m/sup 2/ effective area) at the National Gran Sasso Laboratories. The used observables are the air shower size (N/sub e/) measured by EAS-TOP and the muon number (N /sub mu /) recorded by MACRO, The two detectors are separated on average by 1200 m of rock, and located at a respective zenith angle of about 30 degrees . The energy threshold at the surface for muons reaching the MACRO depth is approximately 1.3 TeV. Such muons are produced in the early stages of the shower development and in a kinematic region quite different from the one relevant for the usual N/sub mu /-N/sub e/ studies. The measurement leads to a primary composition becoming hea...

  15. Oligo-cyclic damage and behaviour of a 304 L austenitic stainless steel according to environment (vacuum, air, PWR primary water) at 300 C

    International Nuclear Information System (INIS)

    De Baglion, L.

    2011-01-01

    Nowadays, for nuclear power plants licensing or operating life extensions, various safety authorities require the consideration of the primary water environment effect on the fatigue life of Pressurized Water Reactor (PWR) components. Thus, this work focused on the study of low cycle fatigue damage kinetics and mechanisms, of a type 304L austenitic stainless steel. Several parameters effects such as temperature, strain rate or strain amplitude were investigated in air as in PWR water. Thanks to targeted in-vacuum tests, the intrinsic influence of these parameters and environments on the fatigue behaviour of the material was studied. It appears that compared with vacuum, air is already an active environment which is responsible for a strong decrease in fatigue lifetime of this steel, especially at 300 C and low strain amplitude. The PWR water coolant environment is more active than air and leads to increased damage kinetics, without any modifications of the initiation sites or propagation modes. Moreover, the decreased fatigue life in PWR water is essentially attributed to an enhancement of both initiation and micropropagation of 'short cracks'. Finally, the deleterious influence of low strain rates on the 304L austenitic stainless steel fatigue lifetime was observed in PWR water environment, in air and also in vacuum without any environmental effects. This intrinsic strain rate effect is attributed to the occurrence of the Dynamic Strain Aging phenomenon which is responsible for a change in deformation modes and for an enhancement of cracks initiation. (author)

  16. Air network performance and hub competitive position: evaluation of primary airports in East and South-East Asia

    NARCIS (Netherlands)

    Burghouwt, G.; de Wit, J.; Veldhuis, J.; Matsumoto, H.

    2009-01-01

    The growth of hub-and-spoke operations has changed the structure of competition among airlines and airports, meaning that airlines now compete both directly (air services from A to B) as well as indirectly (services from A to B via H). Traditional measures of airport performance, such as passenger

  17. Energy spectrum of primary cosmic rays from 1016eV to 1019eV determined from air showers observed at 5200 m a.s.l

    International Nuclear Information System (INIS)

    Aguirre, C.; Mejia, G.R.; Yoshii, H.; Toyoda, Y.

    1977-01-01

    Energy spectra of primary cosmic rays from 10 16 eV to 10 19 eV have been determined from electron-sizes as well as from muon-sizes of the same air showers observed at Mt. Chacaltaya. The spectrum from electron-sizes is significantly higher than that from muon-sizes. The discrepancy is discussed and an explanation is given under the assumption of possible existence of copious direct production of photons besides the production of charged and neutral pions at these high energies. The spectra are also compared with those by other groups and the discrepancies are discussed. (author)

  18. Cooperative observations of air showers in Tasmania looking for anisotropies in 10 to the 13th - 10 to the 14th eV primaries /COALA project/

    Science.gov (United States)

    Fenton, A. G.; Fenton, K. B.; Humble, J. E.; Jacklyn, R. M.; Vrana, A.; Murakami, K.; Fujii, Z.; Yamada, T.; Sakakibara, S.; Fujimoto, K.; Ueno, H.; Nagashima, K.; Kondo, I.

    Observations of cosmic ray air showers in Tasmania beginning in 1981 are discussed. The shower array consists of 18 unit trays of 4-sq m proportional counters deployed over an area of 20 m x 160 m, and showers around a median primary energy of 5 x 10 to the 13th are to be observed. The observations are carried out in order to catch cosmic ray flows in a stereoscopic manner with simultaneous observations in the northern hemisphere, and the shower frequency in a fundamental coincidence mode is expected to be about 16,000 events per year.

  19. Simulation of the time structure of Extensive Air Showers with CORSIKA initiated by various primary particles at Alborz-I observatory level

    Science.gov (United States)

    Bahmanabadi, Mahmud; Moghaddam, Saba Mortazavi

    2018-05-01

    A detailed simulation of showers with various zenith angles in atmosphere produced by different primary particles including gamma, proton, carbon, and iron at Alborz-I observatory level (35∘43‧N, 51∘20‧E, 1200 m a.s.l= 890 gcm-2), in the energy range 3 × 1013 eV-3 × 1015 eV, has been performed by means of the CORSIKA Monte Carlo code. The aim of this study is to examine the time structure of secondary particles in Extensive Air Showers (EAS) produced by the different primary particles. For each primary particle, the distribution of the mean values of the time delays of secondary particles relative to the first particle hitting the ground level in each EAS, = , and the distribution of their mean standard deviations, in terms of distance from the shower core are obtained. The mean thickness and profile of showers as a function of their energy, primary mass, and zenith angle is described.

  20. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  1. Evaluation of Wall Correction Factor of INER's Air-Kerma Primary Standard Chamber and Dose Variation by Source Displacement for HDR 192Ir Brachytherapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2013-01-01

    Full Text Available The aim of the present study was to estimate the wall effect of the self-made spherical graphite-walled cavity chamber with the Monte Carlo method for establishing the air-kerma primary standard of high-dose-rate (HDR 192Ir brachytherapy sources at the Institute of Nuclear Energy Research (INER, Taiwan. The Monte Carlo method established in this paper was also employed to respectively simulate wall correction factors of the 192Ir air-kerma standard chambers used at the National Institute of Standards and Technology (NIST, USA and the National Physical Laboratory (NPL, UK for comparisons and verification. The chamber wall correction calculation results will be incorporated into INER's HDR 192Ir primary standard in the future. For the brachytherapy treatment in the esophagus or in the bronchi, the position of the isotope may have displacement in the cavity. Thus the delivered dose would differ from the prescribed dose in the treatment plan. We also tried assessing dose distribution due to the position displacement of HDR 192Ir brachytherapy source in a phantom with a central cavity by the Monte Carlo method. The calculated results could offer a clinical reference for the brachytherapy within the human organs with cavity.

  2. A regional high-resolution emission inventory of primary air pollutants in 2012 for Beijing and the surrounding five provinces of North China

    Science.gov (United States)

    Liu, Huanjia; Wu, Bobo; Liu, Shuhan; Shao, Panyang; Liu, Xiangyang; Zhu, Chuanyong; Wang, Yong; Wu, Yiming; Xue, Yifeng; Gao, Jiajia; Hao, Yan; Tian, Hezhong

    2018-05-01

    A high resolution regional emission inventory of typical primary air pollutants (PAPs) for the year 2012 in Beijing and the surrounding five provinces (BSFP) of North China is developed. It is compiled with the combination of bottom-up and top-down methods, based on city-level collected activity data and the latest updated specific emission factors for different sources. The considered sources are classified into 12 major categories and totally 36 subcategories with respect to their multi-dimensional characteristics, such as economic sector, combustion facility or industrial process, installed air pollution control devices, etc. Power plant sector is the dominant contributor of NOX emissions with an average contribution of 34.1%, while VOCs emissions are largely emitted from industrial process sources (33.9%). Whereas, other stationary combustion sources represent major sources of primary PM2.5, PM10 and BC emissions, accounting for 22.7%, 30.0% and 33.9% of the total emissions, respectively. Hebei province contributes over 34% of the regional total CO emissions because of huge volume of iron and steel production. By comparison, Shandong province ranks as the biggest contributor for NOX, PM10, PM2.5, SO2, VOCs and OC. Further, the BSFP regional total emissions are spatially distributed into grid cells with a high resolution of 9 km × 9 km using GIS tools and surrogate indexes, such regional population, gross domestic product (GDP) and the types of arable soils. The highest emission intensities are mainly located in Beijing-Tianjin-Tangshan area, Jinan-Laiwu-Zibo area and several other cities such as Shijiazhuang, Handan, and Zhengzhou. Furthermore, in order to establish a simple method to estimate and forecast PAPs emissions with macroscopic provincial-level statistical parameters in China, multi-parameter regression equations are firstly developed to estimate emissions outside the BSFP region with routine statistics (e.g. population, total final coal consumption

  3. A primary study on the increasing of efficiency in the computer cooling system by means of external air

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Kim, M. H. [Silla University, Busan (Korea, Republic of)

    2009-07-01

    In recent years, since the continuing increase in the capacity of in personal computer such as the optimal performance, high quality and high resolution image, the computer system's components produce large amounts of heat during operation. This study analyzes and investigates an ability and efficiency of the cooling system inside the computer by means of Central Processing Unit (CPU) and power supply cooling fan. This research was conducted for increasing an ability of the cooling system inside the computer by making a structure which produces different air pressures in an air inflow tube. Consequently, when temperatures of the CPU and room inside computer were compared with a general personal computer, temperatures of the tested CPU, the room and the heat sink were as low as 5 .deg. C, 2.5 .deg. C and 7 .deg. C respectively. In addition to, Revolution Per Minute (RPM) was shown as low as 250 after 1 hour operation. This research explored the possibility of enhancing the effective cooling of high-performance computer systems.

  4. Contribution to the study of the distribution of air within the lung using xenon 133 during primary bronchial carcinoma

    International Nuclear Information System (INIS)

    Laval, P.; Vigne, J.; Feliciano, J.M.; Kleisbauer, J.P.; Poirier, R.; Lins, M.I.

    1975-01-01

    An Anger gamma-camera coupled with a two route integrator to record graphs giving the activity of each lung, and a computer with two analog-digital converters for storage of data on paper and magnetic tape, were used. 133 Xe is inhaled in a closed circuit, then a radioactive bolus is given intravenously and expired. The present programme includes a count for each lung, the percentage of ventilation between the right and left lung, the percentage of aerial distribution of the 9 different areas for each lung compared with the whole of the side under consideration, restoration of the distribution curves on inspiration and wash-out on expiration for each of these zones. Study of 14 patients with primary bronchial carcinoma is made. The results are analyzed, typical cases are given, and the future prospects of the method, which may suggest a physical model reproducing the respiratory apparatus of a given subject, are discussed [fr

  5. Impact of primary and secondary air supply intensity in stove on emissions of size-segregated particulate matter and carbonaceous aerosols from apple tree wood burning

    Science.gov (United States)

    Sun, Jian; Shen, Zhenxing; Zhang, Leiming; Zhang, Qian; Lei, Yali; Cao, Junji; Huang, Yu; Liu, Suixin; Zheng, Chunli; Xu, Hongmei; Liu, Hongxia; Pan, Hua; Liu, Pingping; Zhang, Renjian

    2018-04-01

    In order to assess emission factors (EF) more accurately from household biomass burning, a series of laboratory-controlled apple tree wood burning tests were conducted to measure the EFs of size-segregated particulate matter (PM) and carbonaceous aerosols. The controlled burning experiments were conducted with designed primary air (PA) and secondary air (SA) supply intensity. An optimum value of 7 m3·h- 1 was found for SA, resulting the highest modified combustion efficiency (92.4 ± 2.5%) as well as the lowest EFs of PM2.5 (0.13 ± 0.01 g·MJ- 1), OC (0.04 ± 0.03 g·MJ- 1) and EC (0.03 ± 0.01 g·MJ- 1). SA values of 7 and 10 m3·h- 1 resulted the lowest EFs for all the different PM sizes. In a test with PA of 6 m3·h- 1 and SA of 7 m3·h- 1, very low EFs were observed for OC1 (8.2%), OC2 (11.2%) and especially OP (Pyrolyzed OC) (0%, not detected), indicating nearly complete combustion under this air supply condition. Besides SA, higher PA was proved to have positive effects on PM and carbonaceous fraction emission reduction. For example, with a fixed SA of 1.5 m3·h- 1, EFs of PM2.5 decreased from 0.64 to 0.27 g·MJ- 1 when PA increased from 6 to 15 m3·h- 1 (P < 0.05). Similar reductions were also observed in EFs of OC, EC and size segregated PM.

  6. Exposure to air pollution and meteorological factors associated with children's primary care visits at night due to asthma attack: case-crossover design for 3-year pooled patients.

    Science.gov (United States)

    Yamazaki, Shin; Shima, Masayuki; Yoda, Yoshiko; Oka, Katsumi; Kurosaka, Fumitake; Shimizu, Shigeta; Takahashi, Hironobu; Nakatani, Yuji; Nishikawa, Jittoku; Fujiwara, Katsuhiko; Mizumori, Yasuyuki; Mogami, Akira; Yamada, Taku; Yamamoto, Nobuharu

    2015-05-03

    We examined the association of outdoor air pollution and meteorological parameters with primary care visits (PCVs) at night due to asthma attack. A case-crossover study was conducted in a primary care clinic in Himeji City, Japan. Participants were 1447 children aged 0-14 years who visited the clinic with an asthma attack from April 2010 until March 2013. Daily concentrations of air pollutants and meteorological parameters were measured. PCVs at night due to asthma attack. A conditional logistic regression model was used to estimate ORs of PCVs per unit increment of air pollutants or meteorological parameters (the per-unit increments of particulate matter with an aerodynamic diameter ≤2.5 µm (PM₂.₅) and ozone were 10 μg/m(3) and 10 ppb, respectively). Analyses took into consideration the effects of seasonality. We noted an association between PCVs and daily ozone levels on the day before a PCV (OR=1.17; 95% CI 1.01 to 1.35; p=0.04), as well as between PCVs and 3-day mean ozone levels before a PCV (OR=1.29; 95% CI 1.00 to 1.46; p=0.04), from April until June. We also observed an association between PCVs and daily PM₂.₅ levels on the day before a PCV from December until March (OR=1.16; 95% CI 1.01 to 1.33; p=0.05). Meteorological parameters, such as hours of sunshine from September until November, atmospheric pressure from April until June, and temperature from April until August, were also found to be associated with PCVs. The findings in the present study supported an association between ozone and PCVs and suggest that certain meteorological items may be associated with PCVs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Culture of primary ciliary dyskinesia epithelial cells at air-liquid interface can alter ciliary phenotype but remains a robust and informative diagnostic aid.

    Directory of Open Access Journals (Sweden)

    Robert A Hirst

    Full Text Available The diagnosis of primary ciliary dyskinesia (PCD requires the analysis of ciliary function and ultrastructure. Diagnosis can be complicated by secondary effects on cilia such as damage during sampling, local inflammation or recent infection. To differentiate primary from secondary abnormalities, re-analysis of cilia following culture and re-differentiation of epithelial cells at an air-liquid interface (ALI aids the diagnosis of PCD. However changes in ciliary beat pattern of cilia following epithelial cell culture has previously been described, which has brought the robustness of this method into question. This is the first systematic study to evaluate ALI culture as an aid to diagnosis of PCD in the light of these concerns.We retrospectively studied changes associated with ALI-culture in 158 subjects referred for diagnostic testing at two PCD centres. Ciliated nasal epithelium (PCD n = 54; non-PCD n  111 was analysed by high-speed digital video microscopy and transmission electron microscopy before and after culture.Ciliary function was abnormal before and after culture in all subjects with PCD; 21 PCD subjects had a combination of static and uncoordinated twitching cilia, which became completely static following culture, a further 9 demonstrated a decreased ciliary beat frequency after culture. In subjects without PCD, secondary ciliary dyskinesia was reduced.The change to ciliary phenotype in PCD samples following cell culture does not affect the diagnosis, and in certain cases can assist the ability to identify PCD cilia.

  8. Characterization of active ion transport across primary rabbit corneal epithelial cell layers (RCrECL) cultured at an air-interface.

    Science.gov (United States)

    Chang-Lin, Joan-En; Kim, Kwang-Jin; Lee, Vincent H L

    2005-06-01

    Previously, we reported the development of a primary culture model of tight rabbit corneal epithelial cell layers (RCrECL) characterizing bioelectric parameters, morphology, cytokeratin, and passive permeability. In the present study, we specifically evaluated the active ion transport processes of RCrECL cultured from either pigmented or albino rabbits. Primary cultured RCrECL were grown at an air-interface on Clear-Snapwells precoated with collagen/fibronectin/laminin and mounted in a modified Ussing-type chamber for the evaluation of their active ion transport processes under short-circuited conditions. Contribution of active Na(+) and Cl(-) transport to overall short-circuit current (I(sc)) was evaluated by removing Na(+) and Cl(-), respectively, from bathing fluids of RCrECL and measurements of net fluxes of Na(+) and Cl(-) using (22)Na and (36)Cl, respectively. Amiloride and benzamil were used to determine the role of apical Na(+)-channel activities to net Na(+) fluxes. N-phenylanthranilic acid (NPAA), ouabain, BaCl(2) and bumetanide were used to determine the role of basolateral Na,K-ATPase, apical Cl(-)-channel, and basolateral K(+)-channel and Na(+)(K(+))2Cl(-)-cotransporter activities, respectively, in active ion transport across RCrECL. I(sc) of RCrECL derived from pigmented rabbits was comprised of 64+/-2% and 44+/-5% for active Na(+) and Cl(-) transport, respectively, consistent with net Na(+) absorption and Cl(-) secretion of 0.062+/-0.006 and 0.046+/-0.008 muEq/cm(2)/hr estimated from radionuclide fluxes. Apical amiloride and benzamil inhibited I(sc) by up to approximately 50% with an IC(50) of 1 and 0.1 microm, respectively, consistent with participation of apical epithelial Na(+)-channels to net Na(+) absorption across RCrECL cultured from pigmented rabbits. Addition of ouabain to the basolateral, NPAA to the apical, BaCl(2) to the basolateral and bumetanide to basolateral fluid decreased I(sc) by 86+/-1.5%, 53+/-3%, 18+/-1.8% and 13+/-1.9% in RCr

  9. Measurement of actinides in samples from effluent air, primary coolant and effluent water of nuclear power stations in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.; Rosner, G.

    1977-01-01

    Since the middle of 1973 the alpha radioactivity of a number of aerosol filters from the stack monitoring systems of some nuclear power stations, of water effluent samples from all german nuclear power stations and of samples from the primary coolant water of one nuclear power reactor was measured. Essentially, the following procedures of sample preparation for alpha spectrometry of the samples in large area gridded ionization chambers were used; cold ashing of the aerosol samples in 'excited' oxygen, coprecipitation of the alpha emitters from the effluent water samples with iron hydroxide and subsequent cold ashing of the precipitate, and evaporation of the samples from the primary cycle on stainless steel plates. The following transuranium nuclides, or some of them, were found in the samples of the primary coolant and in several aerosol filter samples: Pu-239/240, Pu-238 and/or Am-241, Cm-242 and Cm-244. Cm-242 contributes most to the alpha radioactivity in fresh samples. In the effluent water samples Cm-242, Pu-239/240 and Pu-238 and/or Am-241 were identified in some cases, in one case also Cm-244. Detection limits of the procedures used for the analysis of the above stated transuranium nuclides were in the order of 0,1 fCi per m 3 for the aerosol samples and of 0.2 pCi per 1 for the liquid samples. For the effluent air and water samples in most cases specific activities near the detection limit or somewhat higher were found. On the basis of the measurements, an estimation of the annual actinides releases from nuclear power stations in the Federal Republic of Germany is given

  10. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  11. The response of guinea pig primary utricular and saccular irregular neurons to bone-conducted vibration (BCV) and air-conducted sound (ACS).

    Science.gov (United States)

    Curthoys, Ian S; Vulovic, Vedran; Burgess, Ann M; Sokolic, Ljiljana; Goonetilleke, Samanthi C

    2016-01-01

    This study sought to characterize the response of mammalian primary otolithic neurons to sound and vibration by measuring the resting discharge rates, thresholds for increases in firing rate and supra-threshold sensitivity functions of guinea pig single primary utricular and saccular afferents. Neurons with irregular resting discharge were activated in response to bone conducted vibration (BCV) and air conducted sound (ACS) for frequencies between 100 Hz and 3000 Hz. The location of neurons was verified by labelling with neurobiotin. Many afferents from both maculae have very low or zero resting discharge, with saccular afferents having on average, higher resting rates than utricular afferents. Most irregular utricular and saccular afferents can be evoked by both BCV and ACS. For BCV stimulation: utricular and saccular neurons show similar low thresholds for increased firing rate (around 0.02 g on average) for frequencies from 100 Hz to 750 Hz. There is a steep increase in rate change threshold for BCV frequencies above 750 Hz. The suprathreshold sensitivity functions for BCV were similar for both utricular and saccular neurons, with, at low frequencies, very steep increases in firing rate as intensity increased. For ACS stimulation: utricular and saccular neurons can be activated by high intensity stimuli for frequencies from 250 Hz to 3000 Hz with similar flattened U-shaped tuning curves with lowest thresholds for frequencies around 1000-2000 Hz. The average ACS thresholds for saccular afferents across these frequencies is about 15-20 dB lower than for utricular neurons. The suprathreshold sensitivity functions for ACS were similar for both utricular and saccular neurons. Both utricular and saccular afferents showed phase-locking to BCV and ACS, extending up to frequencies of at least around 1500 Hz for BCV and 3000 Hz for ACS. Phase-locking at low frequencies (e.g. 100 Hz) imposes a limit on the neural firing rate evoked by the stimulus since the

  12. Experimental study of the effects of swirl and air dilution on biogas non-premixed flame stability

    Directory of Open Access Journals (Sweden)

    Rowhani Amir

    2015-01-01

    Full Text Available An experimental investigation of the stability limits of biogas in a swirling non-premixed burner has been carried out. A mixture of 60% methane (CH4 and 40% carbon dioxide (CO2 was used to reach the typical biogas composition. Vane swirlers with 30º, 45º and 60º angles were used to make the swirling air. The biogas stability limits and flame behavior under swirling conditions were tested. Besides, effects of air dilution with nitrogen (N2 and CO2 on biogas stability limits were investigated. The results show that using swirl can enhance the flame stability limits approximately four or five times comparing to non-swirling air stream. Adding N2/CO2 to the air had negative effects on the flame stability but no changes were observed in the flame structure. The maximum air dilution was also obtained when 27% and 15% N2 was added to the swirling air under strong and weak swirl, respectively.

  13. Characterization of primary biogenic aerosol particles in urban, rural, and high-alpine air by DNA sequence and restriction fragment analysis of ribosomal RNA genes

    Directory of Open Access Journals (Sweden)

    V. R. Després

    2007-12-01

    Full Text Available This study explores the applicability of DNA analyses for the characterization of primary biogenic aerosol (PBA particles in the atmosphere. Samples of fine particulate matter (PM2.5 and total suspended particulates (TSP have been collected on different types of filter materials at urban, rural, and high-alpine locations along an altitude transect in the south of Germany (Munich, Hohenpeissenberg, Mt. Zugspitze.

    From filter segments loaded with about one milligram of air particulate matter, DNA could be extracted and DNA sequences could be determined for bacteria, fungi, plants and animals. Sequence analyses were used to determine the identity of biological organisms, and terminal restriction fragment length polymorphism analyses (T-RFLP were applied to estimate diversities and relative abundances of bacteria. Investigations of blank and background samples showed that filter materials have to be decontaminated prior to use, and that the sampling and handling procedures have to be carefully controlled to avoid artifacts in the analyses.

    Mass fractions of DNA in PM2.5 were found to be around 0.05% in urban, rural, and high-alpine aerosols. The average concentration of DNA determined for urban air was on the order of ~7 ng m−3, indicating that human adults may inhale about one microgram of DNA per day (corresponding to ~108 haploid bacterial genomes or ~105 haploid human genomes, respectively.

    Most of the bacterial sequences found in PM2.5 were from Proteobacteria (42 and some from Actinobacteria (10 and Firmicutes (1. The fungal sequences were characteristic for Ascomycota (3 and Basidiomycota (1, which are known to actively discharge spores into the atmosphere. The plant sequences could be attributed to green plants (2 and moss spores (2, while animal DNA was found only for one unicellular eukaryote (protist.

  14. Primary and oxidative DNA damage in salivary leukocytes as a tool for the evaluation of air pollution early biological effects in children: current status of the MAPEC (Monitoring Air Pollution Effects on Children for supporting public health policy study

    Directory of Open Access Journals (Sweden)

    Samuele Vannini

    2015-05-01

    Conclusions - The main objective of the MAPEC study is to evaluate the associations in children between air pollutants and early biological effects, and to propose a model for estimating the global genotoxic risk.

  15. Evaluation of chemical transport model predictions of primary organic aerosol for air masses classified by particle component-based factor analysis

    Directory of Open Access Journals (Sweden)

    C. A. Stroud

    2012-09-01

    Full Text Available Observations from the 2007 Border Air Quality and Meteorology Study (BAQS-Met 2007 in Southern Ontario, Canada, were used to evaluate predictions of primary organic aerosol (POA and two other carbonaceous species, black carbon (BC and carbon monoxide (CO, made for this summertime period by Environment Canada's AURAMS regional chemical transport model. Particle component-based factor analysis was applied to aerosol mass spectrometer measurements made at one urban site (Windsor, ON and two rural sites (Harrow and Bear Creek, ON to derive hydrocarbon-like organic aerosol (HOA factors. A novel diagnostic model evaluation was performed by investigating model POA bias as a function of HOA mass concentration and indicator ratios (e.g. BC/HOA. Eight case studies were selected based on factor analysis and back trajectories to help classify model bias for certain POA source types. By considering model POA bias in relation to co-located BC and CO biases, a plausible story is developed that explains the model biases for all three species.

    At the rural sites, daytime mean PM1 POA mass concentrations were under-predicted compared to observed HOA concentrations. POA under-predictions were accentuated when the transport arriving at the rural sites was from the Detroit/Windsor urban complex and for short-term periods of biomass burning influence. Interestingly, the daytime CO concentrations were only slightly under-predicted at both rural sites, whereas CO was over-predicted at the urban Windsor site with a normalized mean bias of 134%, while good agreement was observed at Windsor for the comparison of daytime PM1 POA and HOA mean values, 1.1 μg m−3 and 1.2 μg m−3, respectively. Biases in model POA predictions also trended from positive to negative with increasing HOA values. Periods of POA over-prediction were most evident at the urban site on calm nights due to an overly-stable model surface layer

  16. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber; Estabelecimento de um sistema padrao primario para raios-X de energias baixas com uma camara de ionizacao de ar livre

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natalia Fiorini da

    2016-08-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  17. Primary production of phytoplankton of Chascomus Pond (Prov. Buenos Aires (Argentina)). Critical evaluation of photosynthesis values obtained by O2 and 14 C methods

    International Nuclear Information System (INIS)

    Romero, M.C.; Arenas, P.M.

    1989-01-01

    The primary production of the phytoplankton of Chascomus pound was estimated with the dissolved oxygen and the assimilation of 14 CO 2 techniques, the laboratory, at light saturation. The bicarbonate consumptions by the phytoplankton was corrected by the excretion values, anaplerotic uptake of CO 2 by heterotrophic bacteria and for adsorption on suspended material. Gross production primary values fluctuated within 619,5 and 168,9 mg C.m -3 . h -1 , the net primary production within 564,8 (summer) and 93,8 (winter) mg C.m -3 . h -1 . Steemann Nielsen's technique subestimated the primary production in an average of the 21%; during the months of December, January and February those differences were only of the 8,6 and 1% respectively, implying that carrying out the respective corrections, both methods equalize themselves. (author)

  18. Genetics Home Reference: primary spontaneous pneumothorax

    Science.gov (United States)

    ... Home Health Conditions Primary spontaneous pneumothorax Primary spontaneous pneumothorax Printable PDF Open All Close All Enable Javascript ... view the expand/collapse boxes. Description Primary spontaneous pneumothorax is an abnormal accumulation of air in the ...

  19. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  20. Air pollution

    International Nuclear Information System (INIS)

    Nelson, P.

    2000-01-01

    Australian cites experience a number of current and emerging air pollution problems. Concentrations of traditional primary pollutants such as CO, lead and dust have fallen in recent years as a consequence of air pollutant control measures, and the widespread introduction of lead-free petrol. However, recommended guidelines for ozone, the principal component of photochemical smog, are regularly exceeded in major capital cities in the summer months. In addition, it is predicted that extensive urban expansion will lead to much greater dependence on the motor vehicle as the primary means of transportation. Effects of air pollution are felt at a variety of scales. Traditionally, concerns about gaseous and particulate emissions from industrial and vehicular sources were focused on local impacts due to exposure to toxic species such as CO and lead. As noted above, concentrations of these pollutants have been reduced by a variety of control measures. Pollutants which have effects at a regional scale, such as photochemically-produced ozone, and acidic gases and particles have proved more difficult to reduce. In general, these pollutants arc not the result of direct emissions to atmosphere, but result from complex secondary processes driven by photochemical reactions of species such as NO 2 and aldehydes. In addition, global effects of gaseous and particulate emissions to the atmosphere have received significant recent attention, concentrations of atmospheric CO 2 with predicted impacts on global climate, and ozone depletion due to anthropogenic emissions of chlorine-containing chemicals are the two major examples. Combustion processes from petrol- and diesel-fuelled vehicles, make major contributions to air pollution, and the magnitude of this contribution is discussed in this article

  1. Facile Synthesis of Defect-Rich and S/N Co-Doped Graphene-Like Carbon Nanosheets as an Efficient Electrocatalyst for Primary and All-Solid-State Zn-Air Batteries.

    Science.gov (United States)

    Zhang, Jian; Zhou, Huang; Zhu, Jiawei; Hu, Pei; Hang, Chao; Yang, Jinlong; Peng, Tao; Mu, Shichun; Huang, Yunhui

    2017-07-26

    Developing facile and low-cost porous graphene-based catalysts for highly efficient oxygen reduction reaction (ORR) remains an important matter for fuel cells. Here, a defect-enriched and dual heteroatom (S and N) doped hierarchically porous graphene-like carbon nanomaterial (D-S/N-GLC) was prepared by a simple and scalable strategy, and exhibits an outperformed ORR activity and stability as compared to commercial Pt/C catalyst in an alkaline condition (its half-wave potential is nearly 24 mV more positive than Pt/C). The excellent ORR performance of the catalyst can be attributed to the synergistic effect, which integrates the novel graphene-like architectures, 3D hierarchically porous structure, superhigh surface area, high content of active dopants, and abundant defective sites in D-S/N-GLC. As a result, the developed catalysts are used as the air electrode for primary and all-solid-state Zn-air batteries. The primary batteries demonstrate a higher peak power density of 252 mW cm -2 and high voltage of 1.32 and 1.24 V at discharge current densities of 5 and 20 mA cm -2 , respectively. Remarkably, the all-solid-state battery also exhibits a high peak power density of 81 mW cm -2 with good discharge performance. Moreover, such catalyst possesses a comparable ORR activity and higher stability than Pt/C in acidic condition. The present work not only provides a facile but cost-efficient strategy toward preparation of graphene-based materials, but also inspires an idea for promoting the electrocatalytic activity of carbon-based materials.

  2. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, it's ...

  3. Comparison of vectorial ion transport in primary murine airway and human sinonasal air-liquid interface cultures, models for studies of cystic fibrosis, and other airway diseases.

    Science.gov (United States)

    Zhang, Shaoyan; Fortenberry, James A; Cohen, Noam A; Sorscher, Eric J; Woodworth, Bradford A

    2009-01-01

    The purpose of this study was to compare vectorial ion transport within murine trachea, murine nasal septa, and human sinonasal cultured epithelium. Our hypothesis is that murine septal epithelium, rather than trachea, will more closely mimic the electrophysiology properties of human sinonasal epithelium. Epithelium from murine trachea, murine septa, and human sinonasal tissue were cultured at an air-liquid interface to confluence and full differentiation. A limited number of homozygous dF508 epithelia were also cultured. Monolayers were mounted in modified Ussing chambers to investigate pharmacologic manipulation of ion transport. The change in forskolin-stimulated current (delta-I(SC), expressed as micro-A/cm(2)) in murine septal (n = 19; 16.84 +/- 2.09) and human sinonasal (n = 18; 12.15 +/- 1.93) cultures was significantly increased over murine tracheal cultures (n = 15; 6.75 +/- 1.35; p = 0.035 and 0.0005, respectively). Forskolin-stimulated I(SC) was inhibited by the specific cystic fibrosis transmembrane regulator (CFTR) inhibitor INH-172 (5 microM). No forskolin-stimulated I(SC) was shown in cultures of dF508 homozygous murine septal epithelium (n = 3). Murine septal I(SC) was largely inhibited by amiloride (12.03 +/- 0.66), whereas human sinonasal cultures had a very limited response (0.70 +/- 0.47; p < 0.0001). The contribution of CFTR to stimulated chloride current as measured by INH-172 was highly significantly different between all groups (murine septa, 19.51 +/- 1.28; human sinonasal, 11.12 +/- 1.58; murine trachea, 4.85 +/- 0.49; p < 0.0001). Human sinonasal and murine septal epithelial cultures represent a useful model for studying CFTR activity and may provide significant advantages over lower airway tissues for investigating upper and lower respiratory pathophysiology.

  4. Influence of air flow parameters on nanosecond repetitively pulsed discharges in a pin-annular electrode configuration

    KAUST Repository

    Heitz, Sylvain A; Moeck, Jonas P; Schuller, Thierry; Veynante, Denis; Lacoste, Deanna

    2016-01-01

    The effect of various air flow parameters on the plasma regimes of nanosecond repetitively pulsed (NRP) discharges is investigated at atmospheric pressure. The two electrodes are in a pin-annular configuration, transverse to the mean flow. The voltage pulses have amplitudes up to 15 kV, a duration of 10 ns and a repetition frequency ranging from 15 to 30 kHz. The NRP corona to NRP spark (C-S) regime transition and the NRP spark to NRP corona (S-C) regime transition are investigated for different steady and harmonically oscillating flows. First, the strong effect of a transverse flow on the C-S and S-C transitions, as reported in previous studies, is verified. Second, it is shown that the azimuthal flow imparted by a swirler does not affect the regime transition voltages. Finally, the influence of low frequency harmonic oscillations of the air flow, generated by a loudspeaker, is studied. A strong effect of frequency and amplitude of the incoming flow modulation on the NRP plasma regime is observed. Results are interpreted based on the cumulative effect of the NRP discharges and an analysis of the residence times of fluid particles in the inter-electrode region. © 2016 IOP Publishing Ltd.

  5. Influence of air flow parameters on nanosecond repetitively pulsed discharges in a pin-annular electrode configuration

    KAUST Repository

    Heitz, Sylvain A

    2016-03-16

    The effect of various air flow parameters on the plasma regimes of nanosecond repetitively pulsed (NRP) discharges is investigated at atmospheric pressure. The two electrodes are in a pin-annular configuration, transverse to the mean flow. The voltage pulses have amplitudes up to 15 kV, a duration of 10 ns and a repetition frequency ranging from 15 to 30 kHz. The NRP corona to NRP spark (C-S) regime transition and the NRP spark to NRP corona (S-C) regime transition are investigated for different steady and harmonically oscillating flows. First, the strong effect of a transverse flow on the C-S and S-C transitions, as reported in previous studies, is verified. Second, it is shown that the azimuthal flow imparted by a swirler does not affect the regime transition voltages. Finally, the influence of low frequency harmonic oscillations of the air flow, generated by a loudspeaker, is studied. A strong effect of frequency and amplitude of the incoming flow modulation on the NRP plasma regime is observed. Results are interpreted based on the cumulative effect of the NRP discharges and an analysis of the residence times of fluid particles in the inter-electrode region. © 2016 IOP Publishing Ltd.

  6. Expression and functional activity of P-glycoprotein in passaged primary human nasal epithelial cell monolayers cultured by the air-liquid interface method for nasal drug transport study.

    Science.gov (United States)

    Cho, Hyun-Jong; Choi, Min-Koo; Lin, Hongxia; Kim, Jung Sun; Chung, Suk-Jae; Shim, Chang-Koo; Kim, Dae-Duk

    2011-03-01

    P-glycoprotein (P-gp) is an efflux transporter encoded by the multidrug resistance gene (MDR1), which is also known as the human ABCB1 gene (ATP-binding cassette, subfamily-B). The objectives of this study were to investigate the expression of P-gp in passaged primary human nasal epithelial (HNE) cell monolayer, cultured by the air-liquid interface (ALI) method, and to evaluate its feasibility as an in-vitro model for cellular uptake and transport studies of P-gp substrates. Reverse transcriptase-polymerase chain reaction (RT-PCR) was performed to verify the expression of the MDR1 gene. Transport and cellular uptake studies with P-gp substrate (rhodamine123) and P-gp inhibitors (verapamil and cyclosporin A) were conducted to assess the functional activity of P-gp in HNE cell monolayers cultured by the ALI method. MDR1 gene expression in primary HNE cell monolayers cultured by ALI method was confirmed by RT-PCR. The apparent permeability coefficient (P(app) ) of the P-gp substrate (rhodamine123) in the basolateral to apical (B to A) direction was 6.9 times higher than that in the apical to basolateral (A to B) direction. B to A transport was saturated at high rhodamine123 concentration, and the treatment of P-gp inhibitors increased cellular uptake of rhodamine123 in a time- and concentration-dependent manner. These results support the MDR1 gene expression and the functional activity of P-gp in primary HNE cell monolayers cultured by the ALI method. © 2011 The Authors. JPP © 2011 Royal Pharmaceutical Society.

  7. Amenorrhea - primary

    Science.gov (United States)

    ... of periods - primary Images Primary amenorrhea Normal uterine anatomy (cut section) Absence of menstruation (amenorrhea) References Bulun SE. The physiology and pathology of the female reproductive axis. In: ...

  8. Air Abrasion

    Science.gov (United States)

    ... Chapters What Is Air Abrasion? What Happens? The Pros and Cons Will I Feel Anything? Is Air ... will perform any procedures that use air-abrasion technology. Ask your dentist if he or she uses ...

  9. Calculation of the correction factors for the primary standard of kerma in the air at the LNMRI-IRD, Rio de Janeiro, Brazil; Calculo de fatores de correcao para o padrao primario em kerma no ar do LNMRI-IRD, Rio de Janeiro, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cosme Norival Mello da, E-mail: cosme@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)

    2009-07-01

    In order to determine the primary standardization in terms of kerma in the air, a graphite ionization chamber is used for calculation some correction factors. A program was elaborated, using the Monte Carlo Penelope for simulate the CC01-110 at the LNMRI/IRD, Rio de Janeiro, Brazil

  10. Construction of a laboratory for the implantation of primary standardization of the magnitude kerma in the air for the X-ray beams used in mammography; Construcao de um laboratorio para a implantacao da padronizacao primaria da grandeza kerma no ar para os feixes de raios X empregados em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Cardozo, W.L.; Magalhes, L.A.A.M.F.; Peixoto, J.G.P., E-mail: wagnerlc@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)

    2009-07-01

    Aiming to diminish the uncertainty in each phase of the metrological chain, and the uncertainty in dosimetry processed at the X-ray beam applied in the mammography, is necessary that the LNMRI/IRD to develop a reference primary standard for the absolute form to the magnitude kerma in the air

  11. Flow characteristics of centrifugal gas-liquid separator. Investigation with air-water two-phase flow experiment

    International Nuclear Information System (INIS)

    Yoneda, Kimitoshi; Inada, Fumio

    2004-01-01

    Air-water two-phase flow experiment was conducted to examine the basic flow characteristics of a centrifugal gas-liquid separator. Vertical transparent test section, which is 4 m in height, was used to imitate the scale of a BWR separator. Flow rate conditions of gas and liquid were fixed at 0.1 m 3 /s and 0.033 m 3 /s, respectively. Radial distributions of two-phase flow characteristics, such as void fraction, gas velocity and bubble chord length, were measured by traversing dual optical void probes in the test section, horizontally. The flow in the standpipe reached to quasi-developed state within the height-to-diameter aspect ratio H/D=10, which in turn can mean the maximum value for an ideal height design of a standpipe. The liquid film in the barrel showed a maximum thickness at 0.5 to 1 m in height from the swirler exit, which was a common result for three different standpipe length conditions, qualitatively and quantitatively. The empirical database obtained in this study would contribute practically to the validation of numerical analyses for an actual separator in a plant, and would also be academically useful for further investigations of two-phase flow in large-diameter pipes. (author)

  12. Air Risk Information Support Center

    Energy Technology Data Exchange (ETDEWEB)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  13. 77 FR 12482 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality...

    Science.gov (United States)

    2012-03-01

    ... Promulgation of Air Quality Implementation Plans; Indiana; Lead Ambient Air Quality Standards AGENCY... incorporates the National Ambient Air Quality Standards (NAAQS) for Pb promulgated by EPA in 2008. DATES: This... FR 66964) and codified at 40 CFR 50.16, ``National primary and secondary ambient air quality...

  14. Phase II Recommendations by the Air Quality Management Subcommittee to the Clean Air Act Advisory Committee

    Science.gov (United States)

    The primary charge of the AQM Subcommittee was to develop recommendations to improve the air quality management system and address the air quality challenges in this country expected over the next 10 to 20 years. This report addresses those challenges.

  15. 30 CFR 250.302 - Definitions concerning air quality.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Definitions concerning air quality. 250.302... Definitions concerning air quality. For purposes of §§ 250.303 and 250.304 of this part: Air pollutant means..., pursuant to section 109 of the Clean Air Act, national primary or secondary ambient air quality standards...

  16. Primary explosives

    Energy Technology Data Exchange (ETDEWEB)

    Matyas, Robert; Pachman, Jiri [Pardubice Univ. (Czech Republic). Faculty of Chemical Technology

    2013-06-01

    The first chapter provides background such as the basics of initiation and differences between requirements on primary explosives used in detonators and igniters. The authors then clarify the influence of physical characteristics on explosive properties, focusing on those properties required for primary explosives. Furthermore, the issue of sensitivity is discussed. All the chapters on particular groups of primary explosives are structured in the same way, including introduction, physical and chemical properties, explosive properties, preparation and documented use.

  17. Primary fibromyalgia

    DEFF Research Database (Denmark)

    Jacobsen, S; Jensen, L T; Foldager, M

    1990-01-01

    Serum concentrations of procollagen type III aminoterminal peptide have previously been reported to be low in some patients with primary fibromyalgia and the aim of this study was to determine if such patients differ clinically from primary fibromyalgia patients with normal levels of procollagen...... type III aminoterminal peptide. Subjective symptoms, tender points and dynamic muscle strength in 45 women with primary fibromyalgia were related to serum concentrations of procollagen type III aminoterminal peptide. Patients with low serum concentrations of procollagen type III aminoterminal peptide...... concentrations of procollagen type III aminoterminal peptide of primary fibromyalgia patients are connected to the disease impact....

  18. Integrated Heat Air & Moisture Modeling and control

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2007-01-01

    The paper presents a recently developed Heat Air & Moisture Laboratory in SimuLink. The simulation laboratory facilitates the integration of the following models: (1) a whole building model; (2) Heating Venting and Air-Conditioning and primary systems; (3) 2D indoor airflow, 3D Heat Air & Moisture

  19. Primary productivity

    Digital Repository Service at National Institute of Oceanography (India)

    Verlecar, X.N.; Parulekar, A.H.

    Photosynthetic production in the oceans in relation to light, nutrients and mixing processes is discussed. Primary productivity in the estuarine region is reported to be high in comparison to coastal and oceanic waters. Upwelling phenomenon...

  20. Primary Hyperparathyroidism

    Science.gov (United States)

    ... Neoplasia Type 1 Thyroid Disease & Pregnancy Primary Hyperparathyroidism Prolactinoma National Hormone and Pituitary Program (NHPP): Information for ... qualified health care provider nearby. Eating, Diet, and Nutrition Eating, diet, and nutrition have not been shown ...

  1. Primary Myelofibrosis

    Science.gov (United States)

    ... attack is higher. Patients also have an increased risk of acute myeloid leukemia or primary myelofibrosis . Symptoms of polycythemia vera include headaches and a feeling of fullness below the ribs on the left ...

  2. Air pollution

    OpenAIRE

    MacKenbach, JP; Henschel, S; Goodman, P; McKee, M

    2013-01-01

    The human costs of air pollution are considerable in Jordan. According to a report published in 2000 by the World Bank under the Mediterranean Environmental Technical Assistance Program (METAP), approximately 600 people die prematurely each year in Jordan because of urban pollution. 50-90% of air pollution in Jordanian towns is caused by road traffic. Readings taken in 2007 by Jordanian researchers showed that levels of black carbon particles in the air were higher in urban areas (caused by v...

  3. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  4. Air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, W; Mainwaring, S J

    1984-01-01

    This book deals with the nature of air pollution. The numerous sources of unwanted gases and dust particles in the air are discussed. Details are presented of the effects of pollutants on man, animals, vegetation and on inanimate materials. Methods used to measure, monitor and control air pollution are presented. The authors include information on the socio-economic factors which impinge on pollution control and on the problems the future will bring as methods of generating energy change and industries provide new sources of pollutants.

  5. [Hypertension: once primary, always primary?

    NARCIS (Netherlands)

    Braam, R.L.; Pieters, G.F.F.M.; Thien, Th.

    2002-01-01

    Three patients diagnosed with primary hypertension suddenly developed hard-to-treat blood pressure after several years of stable blood pressure. One patient, a man aged 48 years, had developed a renal artery stenosis, which had not been present five years earlier. The other two patients, a man aged

  6. Atmospheric Chemistry and Air Pollution

    Directory of Open Access Journals (Sweden)

    Jeffrey S. Gaffney

    2003-01-01

    Full Text Available Atmospheric chemistry is an important discipline for understanding air pollution and its impacts. This mini-review gives a brief history of air pollution and presents an overview of some of the basic photochemistry involved in the production of ozone and other oxidants in the atmosphere. Urban air quality issues are reviewed with a specific focus on ozone and other oxidants, primary and secondary aerosols, alternative fuels, and the potential for chlorine releases to amplify oxidant chemistry in industrial areas. Regional air pollution issues such as acid rain, long-range transport of aerosols and visibility loss, and the connections of aerosols to ozone and peroxyacetyl nitrate chemistry are examined. Finally, the potential impacts of air pollutants on the global-scale radiative balances of gases and aerosols are discussed briefly.

  7. Air lasing

    CERN Document Server

    Cheng, Ya

    2018-01-01

    This book presents the first comprehensive, interdisciplinary review of the rapidly developing field of air lasing. In most applications of lasers, such as cutting and engraving, the laser source is brought to the point of service where the laser beam is needed to perform its function. However, in some important applications such as remote atmospheric sensing, placing the laser at a convenient location is not an option. Current sensing schemes rely on the detection of weak backscattering of ground-based, forward-propagating optical probes, and possess limited sensitivity. The concept of air lasing (or atmospheric lasing) relies on the idea that the constituents of the air itself can be used as an active laser medium, creating a backward-propagating, impulsive, laser-like radiation emanating from a remote location in the atmosphere. This book provides important insights into the current state of development of air lasing and its applications.

  8. Hyperthyroidism (primary)

    OpenAIRE

    Nygaard, Birte

    2010-01-01

    Hyperthyroidism is characterised by high levels of serum thyroxine and triiodothyronine, and low levels of thyroid-stimulating hormone (TSH). Thyrotoxicosis is the clinical effect of high levels of thyroid hormones, whether or not the thyroid gland is the primary source.The main causes of hyperthyroidism are Graves' disease, toxic multinodular goitre, and toxic adenoma.About 20 times more women than men have hyperthyroidism.

  9. Air Warfare

    Science.gov (United States)

    2002-03-01

    genus as its predecessor of pre-war days. It would, however, be erroneous to conclude from this that the military value of each new development was...the paucity of communications, its conduct, when acting alone, has of necessity to be somewhat stereotyped in nature, and to con- form to a pre...the air, the attack commander, provided his command be equipped with defensive air power, has a rôle to perform which is simple and stereotyped in

  10. Air conditioner

    International Nuclear Information System (INIS)

    Sato, Masaaki

    1993-01-01

    The present invention provides an air conditioner which can prevent an undesirable effects on a human body due to radon daughter nuclides in a closed space. That is, the concentration of the radon daughter nuclides in the air in the closed space is continuously measured. A necessary amount of ventilation air is determined based on the measured concentration to generate control signals. External air is introduced into the closed space by the generated control signals. With such procedures, necessary amount of external air is taken from the atmospheric air which can be regarded to have the radon daughter nuclide concentration substantially at zero, thereby enabling to reduce the concentration of the radon daughter nuclides in the closed space. As a result, undesired effects on the human body due to the radon daughter nuclides staying in the closed space can be prevented. According to simulation, the radon daughter nuclides are rapidly decreased only by ventilation only for three times or so in one hour. Accordingly, ventilation is extremely effective and convenient means as a countermeasure for the radon daughter nuclides. (I.S.)

  11. Application of the total etching technique or self-etching primers on primary teeth after air abrasion Aplicação da técnica de condicionamento total ou de "primers" autocondicionantes em dentes decíduos após abrasão a ar

    Directory of Open Access Journals (Sweden)

    Fábio Renato Manzolli Leite

    2005-09-01

    Full Text Available Since the use of air abrasion has grown in pediatric dentistry, the aim of this study was to evaluate, by means of shear bond strength testing, the need to use the total etching technique or self-etching primers on dentin of primary teeth after air abrasion. Twenty-five exfoliated primary molars had their occlusal dentin exposed by trimming and polishing. Specimens were treated by: Air abrasion + Scotchbond MultiPurpose adhesive (G1; 37% phosphoric acid + Scotchbond MP adhesive (G2; Clearfil SE (G3; Air abrasion + 37% phosphoric acid + Scotchbond MP adhesive (G4; Air abrasion + Clearfil SE (G5. On the treated surface, a cylinder of 2 mm by 6 mm was made using a composite resin (Z100. Duncan's test showed that: (G2 = G3 = G5 > (G1 = G4. The use of a self-etching primer on air abraded dentin is recommended to obtain higher bond strengths.Como o uso da abrasão a ar tem aumentado em odontopediatria, o objetivo deste trabalho foi avaliar a resistência ao cisalhamento da resina composta Z100 sobre a superfície dentinária de dentes decíduos após abrasionamento a ar associado ou não a técnica de condicionamento total (ácido fosfórico + Scotchbond Multi Purpose ou "primer" autocondicionante (Clearfil SE Bond. A superfície oclusal de 25 molares decíduos foi removida para exposição completa da superfície dentinária. Após polimento com lixas abrasivas, foram divididos em 5 grupos (5 espécimes em cada tratados por abrasão + adesivo Scotchbond (G1; condicionamento ácido + adesivo Scotchbond (G2; adesivo Clearfil (G3; abrasão a ar + condicionamento ácido + adesivo Scotchbond (G4; abrasão a ar + adesivo Clearfil (G5. Uma matriz bipartida foi adaptada à superfície dentinária e preenchida com resina composta. Após polimerização, corpos-de-prova de 2 mm x 6 mm foram obtidos. O teste de Duncan mostrou a desigualdade (G1 = G4 < (G2 = G3 = G5. Desse modo, conclui-se que, após o abrasionamento dentinário, deve ser utilizado o sistema de

  12. Structures in the primary spectrum

    International Nuclear Information System (INIS)

    Kempa, J.; Knurenko, S.P.; Malecki, R.

    2009-01-01

    Structures in the energy spectrum of primary cosmic rays at the 'knee' region and for energies higher than 1 EeV are obtained through studying extensive air showers (EAS). The main problem of the research is the fact that we work in the ranges of highly fluctuating parameters used to obtain the primary energy spectrum. In this paper the log-normal distribution for the error function has been used in convolution with the power spectrum to explain the Yakutsk experimental data. Similar results have been obtained for the gamma distribution as the error function. Using the power law primary spectrum in the energy region around 10 19 eV we will argue that the primary Yakutsk spectrum is overestimated. In the best case this overestimation is not less than 42%.

  13. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  14. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  15. Air cathode structure manufacture

    Science.gov (United States)

    Momyer, William R.; Littauer, Ernest L.

    1985-01-01

    An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

  16. Air pollution

    International Nuclear Information System (INIS)

    Feugier, A.

    1996-01-01

    The air pollution results from the combustion of petroleum products, natural gas, coal, wastes and transports. Some compounds are considered as particularly pollutants: the carbon monoxide, the nitrogen oxides, the tropospheric ozone and the sulfur dioxides. Their environmental and biological effects are described. The present political guide lines concerns the combustion plants, the ozone, the wastes incineration and the vehicles emissions. The aim is at some future date to control the air quality, to reduce the volatile organic compounds emissions and to limit the sulfur rate of some petroleum products. (O.L.)

  17. Air pollution from motor vehicle emissions

    International Nuclear Information System (INIS)

    Petrushevska, Ljubica

    1996-01-01

    This paper presents some aspects of air pollution from motor vehicle emissions as: characteristic primary and secondary pollutants, dependence of the motor vehicle emission from the engine type; the relationship of typical engine emission and performance to air-fuel ratio, transport of pollutants from mobile sources of emissions, as well as some world experiences in the control approaches for exhaust emissions. (author)

  18. Extensive air showers

    CERN Document Server

    Rao, M V S

    1997-01-01

    Ultrahigh energy cosmic rays carry information about their sources and the intervening medium apart from providing a beam of particles for studying certain features of high energy interactions currently inaccessible at man-made accelerators. They can at present be studied only via the extensive air showers (EAS's) they generate while passing through the Earth's atmosphere, since their fluxes are too low for the experiments of limited capability flown in balloons and satellites. The EAS is generated by a series of interactions of the primary cosmic ray and its progeny with the atmospheric nucle

  19. Air pollution

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Air pollution has accompanied and developed with the industrial age, since its beginnings. This very complete review furnishes the toxicological data available for the principal pollutants and assesses the epidemiologic studies thus far conducted. It also describes European regulations and international commitments for the reduction of emissions. (author)

  20. Air quality

    International Nuclear Information System (INIS)

    1995-01-01

    This chapter of the 'Assessment of the state of the environment in Lebanon' describes the air quality and identifies the most important air quality issues. Baseline information about the factors affecting dispersion and the climate of Lebanon presents as well and overall estimation of total emissions in Lebanon. Emissions from vehicles, electricity and power plants generation are described. Industrial emitters of air pollutants are described for each kind of industry i.e.cement plants, Selaata fertilizer factory, sugar-beet factory, refineries and for those derived from the use of leaded fuel . Impact of economic and human activities on air quality in Lebanon (especially in Beirut and Tripoli) are quantified by quantities of CO 2 , SO 2 , NO x , total suspended particulates(TSP), deposition and their environmental effects on health. In abscence of emissions monitoring, data available are expressed in terms of fuel use, output and appropriate empirical factors, national output and workfores sizes. Finally key issues and some potential mitigation /management approaches are presented

  1. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  2. Investigations of the detection of α-radioactivity in samples of effluent water primary circuit and exhaust air of nuclear power plants in the FRG in the years 1973-1975

    International Nuclear Information System (INIS)

    Hoetzl, H.; Rosner, G.; Winkler, R.

    1976-05-01

    Since the middle of 1973 the α-radioactivity of aerosol filters from the stack monitoring system and since the middle of 1974 the α-radioactivity in samples from the primary cycle of the KRB was monitored. Effluent water samples of all nuclear power reactors of the FRG were also examined from the middle of 1973 till 1974. Furthermore, aerosol filters sampled in 1973 and 1974 from various places at the KRB and some aerosol filters from the stack monitoring systems of KWW (1973), KWO (1974) and KKS (1975) were also measured. Essentially, the following procedures of sample preparation for α-spectrometry of the samples in large-area gridded ionization chambers were used: cold ashing of the aerosol samples in 'excited' oxygen; coprecipitation of the alpha emitters from the effluent water samples with iron hydroxide and subsequent cold ashing of the precipitate; evaporation of the samples from the primary cycle on SS plates. The following transuranium nuclides, or some of them, were found in the samples of the primary coolant and in several aerosol filter samples: Pu-239/240, Pu-238 and/or Am-241, Cm-242 and Cm-244. Cm-242 contributes most to the α-radioactivity in fresh samples. In the effluent water samples Cm-242. Pu-239/240 and Pu-238 and/or Am-241 were identified in some cases, in one case also Cm-244. The aim of these investigations is to establish procedures for the measurement and surveillance of α-emitting nuclides in the emissions of power reactors in order to study the contribution of transuranium nuclides to the radiation exposure of the population living in the vicinity of nuclear power stations. (orig.) [de

  3. Air quality

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The anthropic pollution sources are essentially industrial or bound to transport. A phenomenon of these last twenty years is the decreasing of the industrial pollution and the increasing of pollution coming from automobiles. Emissions of furans and dioxines coming from municipal wastes are measured. A special attention is mentioned for polycyclic aromatic hydrocarbons coming from incomplete combustions. A last aspect of air pollution is studied with the effect on man, ecosystems and materials, by modeling or direct measurements. (N.C.)

  4. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  5. Air versus gas tamponade in retinal detachment surgery

    NARCIS (Netherlands)

    Tan, H. Stevie; Oberstein, Sarit Y. Lesnik; Mura, Marco; Bijl, Heico M.

    2013-01-01

    Objective To compare the outcome of air tamponade with gas tamponade in primary vitrectomy for the treatment of rhegmatogenous retinal detachment (RRD). Methods We examined the records of 524 cases of 523 patients that underwent primary vitrectomy for RRD with air or sulphur hexafluoride 20% gas

  6. Hazardous Air Pollutants

    Science.gov (United States)

    ... Search Main menu Environmental Topics Air Bed Bugs Chemicals and Toxics Environmental Information by Location Greener Living Health Land, ... regulate toxic air pollutants, also known as air toxics, from categories of industrial facilities in two phases . About Hazardous Air Pollutants ...

  7. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  8. AirData

    Data.gov (United States)

    U.S. Environmental Protection Agency — The AirData site provides access to yearly summaries of United States air pollution data, taken from EPA's air pollution databases. AirData has information about...

  9. Fuel injection and mixing systems having piezoelectric elements and methods of using the same

    Science.gov (United States)

    Mao, Chien-Pei [Clive, IA; Short, John [Norwalk, IA; Klemm, Jim [Des Moines, IA; Abbott, Royce [Des Moines, IA; Overman, Nick [West Des Moines, IA; Pack, Spencer [Urbandale, IA; Winebrenner, Audra [Des Moines, IA

    2011-12-13

    A fuel injection and mixing system is provided that is suitable for use with various types of fuel reformers. Preferably, the system includes a piezoelectric injector for delivering atomized fuel, a gas swirler, such as a steam swirler and/or an air swirler, a mixing chamber and a flow mixing device. The system utilizes ultrasonic vibrations to achieve fuel atomization. The fuel injection and mixing system can be used with a variety of fuel reformers and fuel cells, such as SOFC fuel cells.

  10. An environmental, economical and socio-political analysis of a variety of urban air-pollution reduction policies for primary PM10 and NOx: The case study of the Province of Milan (Northern Italy)

    International Nuclear Information System (INIS)

    Chiesa, M.; Perrone, M.G.; Cusumano, N.; Ferrero, L.; Sangiorgi, G.; Bolzacchini, E.; Lorenzoni, A.; Ballarin Denti, A.

    2014-01-01

    Highlights: • PM10 and NO x emission reduction by different policies have been estimated. • Various actions have been considered, in the transport and residential sectors. • Environmental, economic and socio-political data were jointly evaluated. • Results are reported for the case study of the Province of Milan (Northern Italy). • Bike use fostering best matches cost–benefit results and socio-political acceptance. - Abstract: In the frame of urban air-pollution reduction policies, economic costs and environmental benefits of a variety of actions have been quantitatively assessed for the Province of Milan (Northern Italy), focusing on PM10 and NO x emission sources. Short-to-mid-term interventions that have been taken into consideration include reduction of inner temperature in residential buildings, banning of residential biomass heating systems, banning of diesel fuelled domestic boilers, night-time streets washing, speed limit reduction on highways, circulation restrictions of oldest EURO vehicles, conversion of diesel buses to natural gas, car sharing/biking promotion, DPF adoption in diesel vehicles, extension of road lanes for urban buses, energy efficiency refurbishment in residential buildings. Re*sults emerged from the cost–benefit analysis integrated with socio-political indicators obtained through direct surveys, will contribute, with an holistic and multidisciplinary approach, to drive the local administrators to implement the most suitable actions in one of the most polluted areas in west-Europe

  11. Air quality assessment in Salim Slam Tunnel

    International Nuclear Information System (INIS)

    El-Fadel, M.; Hashisho, Z.; Saikaly, P.

    1999-01-01

    Full text.Vehicle emissions constitute a serious occupational environmental hazard particularly in confined spaces such as tunnels and underground parking garages. these emissions at elevated concentrations, can cause adverse health effects, which range from nausea and eye irritation to mutagenicity, carcinogenicity and even death. This paper presents an environmental air quality assessment in a tunnel located in a highly congested urban area. For this purpose, air samples were collected and analyzed for the presence of primary air pollutants, priority metals, and volatile organic carbons. Air quality modeling was conducted to simulate variations of pollutant concentrations in the tunnel under worst case scenarios including traffic congestion and no air ventilation. Field measurements and mathematical simulation results were used to develop a strategy for proper air quality management in tunnels

  12. Teaching Air Pollution in an Authentic Context

    Science.gov (United States)

    Mandrikas, Achilleas; Stavrou, Dimitrios; Skordoulis, Constantine

    2017-04-01

    This paper describes a teaching-learning sequence (TLS) about air pollution and the findings resulting from its implementation by pre-service elementary teachers (PET) currently undergraduate students of the Department of Primary Education in the National and Kapodistrian University of Athens, Greece. The TLS focused on the relation of air pollution with wind and topography in local conditions. An authentic context was provided to the students based on daily up-to-date meteorological data via the Internet in order to estimate air pollution. The results are encouraging given that PET can correlate wind and concentration of air pollutants through reading specialized angular diagrams and weather maps, can recognize the correlation of topography in the concentration of air pollutants, and can describe temperature inversion. However, the PET demonstrated clear difficulties in ability of orientation, in wind naming, and in interpretation of symbols on weather map. Finally, the implications on teaching air pollution are discussed.

  13. Modelling of air-conditioned and heated spaces

    Energy Technology Data Exchange (ETDEWEB)

    Moehl, U

    1987-01-01

    A space represents a complex system involving numerous components, manipulated variables and disturbances which need to be described if dynamic behaviour of space air is to be determined. A justifiable amount of simulation input is determined by the application of adjusted modelling of the individual components. The determination of natural air exchange in heated spaces and of space-air flow in air-conditioned space are a primary source of uncertainties. (orig.).

  14. Air quality indices : a review

    International Nuclear Information System (INIS)

    Hewings, J.

    2001-10-01

    Pollution Probe presents some background information that will help in the development of a national Air Quality Index (AQI) in Canada. This report examines the issues that should be addressed in revising the national Index of the Quality of Air (IQUA) or creating a new national Air Quality Index. The IQUA was devised in 1976 and provides Canadians with real-time information on the state of community air quality by including major pollutants and their synergies. It is currently being used for air quality management plans and air quality alert systems. At the same time that the IQUA was devised, the United States Environmental Protection Agency (US EPA) produced a parallel air quality index known as the Pollution Standard Index (PSI) which incorporated 5 criteria pollutants (particulate matter, sulphur dioxide, carbon monoxide, nitrogen oxide and ground level ozone) for which national health-based standards were devised. In 1999, the US EPA renamed their index the Air Quality Index (AQI) and made revisions to the primary health-based national ambient air quality standards for ground-level ozone and particulate matter. Separate values for PM2.5 and PM10 were incorporated and mandatory reporting was required for metropolitan areas with populations of 350,000 or more. Similarly, the IQUA has undergone major developments that affect the validity of the index, including: rejection by the Working Group on Air Quality Objectives and Guidelines of the previous maximum desirable and maximum acceptable air quality criteria, recognition that standards for many of the contaminants are outdated, developing more sensitive instrumentation for real-time monitoring of contaminants. This report also describes the use of the national short term Air Quality Index by provincial, territorial and local authorities in Canada. Pollution Probe recommends setting up a mechanism to review and revise IQUA on a regular basis that would incorporate governments, the medical profession, special

  15. Operational test procedure for Bldg 241-A-701 air compressor

    International Nuclear Information System (INIS)

    Desantis, G.N.

    1995-01-01

    This document is an Operability Test Procedure (OTP) which will verify and record that the 241-A-701 air compressor and associated equipment operates within their intended design parameters. The activities defined in this OTP will be performed to ensure the daily operation of the new compressed air system can be reliable and efficient. The Compressed Air System (CAS) for 241-A-701 supplies process and instrument air to the A, AX, AY, and AZ tank farms. The primary use of the CAS is for tank farms instrumentation, air operated valves, and air lift circulators

  16. Air pollution and human mortality

    Energy Technology Data Exchange (ETDEWEB)

    Lave, L B [Carnegie-Mellon Univ., Pittsburgh, PA (USA). Dept. of Economics; Seskin, E P [Department of Commerce, Washington, DC (USA). Environmental and Nonmarket Economics Div.

    1979-11-01

    Investigations have been made on the quantitative relationship between air pollution and human mortality. While primary focus has been on suspended particulates and sulfates from stationary sources of pollution, the evidence relating to air pollutants attributed to mobile sources was also examined. Using statistical analyses for a large number of US metropolitan areas, it was concluded that the benefits associated with a substantial abatement of air pollution from stationary sources are greater than the costs of such abatement. In contrast, the situation for mobile sources-chiefly cars and trucks is less clear-cut. That is, the costs of implementing the currently mandated US standards for automobile emissions probably exeed their potential health benefits.

  17. Calculation note: project W-320 primary ventilation air flow requirements for mitigation of steady state flammable gas concentrations in the headspaces of tanks 241-C-106 and 241-AY-102

    International Nuclear Information System (INIS)

    Estey, S.D.

    1997-01-01

    This calculation note analyzes headspace concentrations of hydrogen dependent upon assumed ventilation flow rates provided for tanks 241-C-106 and 241-AY-102. The analyses are based on measured or estimated steady state hydrogen release rates. Tank 241-C-106 is analyzed prior to sluicing; tank 241-AY-102 is analyzed both prior to and after completion of sluicing. Specific analyses, using both best estimated and bounding hydrogen generation rates, include the minimum primary ventilation flow rates required in the tanks to ensure that the steady state hydrogen concentration in the respective tank headspace does not exceed 25% and 100% of the LFL. The headspace hydrogen concentration as a function of time as well as the time required to reach 25% and 100% of LFL upon complete loss of active ventilation, starting from the steady state hydrogen concentration based on a 200 CFM minimum flow rate in tank 241-C-106 and a 100 CFM minimum flow rate in tank241-AY-102. The headspace hydrogen concentration as a function of thee following partial loss of active ventilation (i.e., step changes to l60, l20, 80, and 40 CFM ventilation flow rates) in tank 241-C-106, staffing from a 200 CFM flow rate and the corresponding steady state hydrogen concentration based on the 200 CFM flow rate. The headspace hydrogen concentration as a function of the following partial loss of active ventilation i.e., step changes to 80, 60, 40, and 20 CFM ventilation flow rates) in tank 241-AY-102, starting from a 100 CFM flow rate and the corresponding steady state hydrogen concentration based on the 100 CFM flow rate

  18. Air Land Sea Bulletin

    Science.gov (United States)

    2014-11-01

    Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based at Royal Air Force Honington, Suffolk (United...heavy as an actual weapon.4 Ideally, this practice imbued a soldier with more energy and stamina during real combat, given the feel of the genuine but...through tactical forces, to individual training. Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based

  19. Las fronteras de la medicalización: tensiones en torno a la identificación y valoración de la desnutrición infantil en un centro de atención primaria de la ciudad de Buenos Aires The frontiers of medicalization: tensions surrounding the identification and appreciation of child malnutrition in a primary healthcare center of the city of Buenos Aires

    Directory of Open Access Journals (Sweden)

    Damián Herkovits

    2012-09-01

    Full Text Available La medicalización de la vida y sus implicancias en cuanto a la producción de subjetividades han sido fenómenos destacados por las ciencias humanas en el estudio de la salud y la enfermedad. Sin embargo, el análisis de sus expresiones locales permanece insuficientemente tratado. El presente trabajo tiene como propósito avanzar en esta dirección mediante el estudio etnográfico del proceso de medicalización de la desnutrición infantil en un centro sanitario de la ciudad de Buenos Aires. Abordaremos las singularidades involucradas en la percepción valorativa del cuerpo y su contexto alimentario por parte de los profesionales de la salud y los destinatarios de sus acciones terapéuticas. Destacamos que los criterios de percepción y los valores morales que animan las posiciones sociales de los profesionales del sector salud y los destinatarios de sus acciones imposibilitaron la institucionalización de la visión médica. Concluimos que el proceso analizado subraya la necesidad de exceder los enfoques que abordan la medicalización exclusivamente desde el ángulo de la imposición. La historia social de los grupos involucrados y los modos de relacionamiento que establecen en escenarios locales constituyen elementos esenciales para comprender las singularidades de estos procesos.The medicalization of life and its implications for the production of subjectivities are phenomena that have been highlighted by the human sciences in the study of health and disease. Nevertheless, the analysis of its local expressions has been insufficiently covered. The scope of this paper is to explore this field by an ethnographical study of the medicalization process of child malnutrition in a primary healthcare center of the city of Buenos Aires. We will describe analytically the singularities involved in the body perception and the alimentary context by health professionals and their patients. We emphasize that the criteria of perception and moral values that

  20. 12th Air Force > Home

    Science.gov (United States)

    Force AOR Travel Info News prevnext Slide show 76,410 pounds of food delivered to Haiti 12th Air Force the French Air Force, Colombian Air Force, Pakistan Air Force, Belgian Air Force, Brazilian Air Force

  1. An analysis of thermal comfort in primary schools in Vietnam

    OpenAIRE

    Le, Thi Ho Vi; Gillott, Mark C.; Rodrigues, Lucélia Taranto

    2017-01-01

    There is a trend of installing air conditioning systems in public primary schools that are currently naturally ventilated in Vietnam. A previous study conducted by the authors provided evidence that there is limited need for air conditioning in Vietnamese mid-season and the hottest season.\\ud \\ud In this study, the authors investigated thermal comfort and users’ perceptions in three primary schools in Ho Chi Minh City during the hottest season (April 2016) and the coldest season (December 201...

  2. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  3. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  4. Air Sensor Toolbox

    Science.gov (United States)

    Air Sensor Toolbox provides information to citizen scientists, researchers and developers interested in learning more about new lower-cost compact air sensor technologies and tools for measuring air quality.

  5. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  6. Indoor Air Quality

    Science.gov (United States)

    ... protect yourself and your family. Learn more Air Quality at Work Workers should breathe easy while on the job, but worksites with poor air quality put employees at risk. Healthy air is essential ...

  7. EPA scientists develop Federal Reference & Equivalent Methods for measuring key air pollutants

    Science.gov (United States)

    EPA operates a nationwide air monitoring network to measure six primary air pollutants: carbon monoxide, lead, sulfur dioxide, ozone, nitrogen dioxide, and particulate matter as part of its mission to protect human health and the environment.

  8. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  9. AirPEx: Air Pollution Exposure Model

    NARCIS (Netherlands)

    Freijer JI; Bloemen HJTh; Loos S de; Marra M; Rombout PJA; Steentjes GM; Veen MP van; LBO

    1997-01-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The

  10. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  11. Kajian Analitik Perencanaan Pintu Air Pembangkit Listrik Tenaga Air

    OpenAIRE

    Pradoto, Pradoto

    1993-01-01

    Pada pintu air pembangkit listrik tenaga air umumnya dipasang pengauat-penguat (girder). Tujuannya agar pintu air kuat dalam menahan tekanan air. Tekanan air yang diderita oleh pintu air cukup besar karena dipasang pada kedalaman + 50 meter di bawah permukaan air. Permasalahan yang timbul adalah menentukan posisi atau letak girder pada pintu air.

  12. Detection of primary coolant leaks in NPP

    International Nuclear Information System (INIS)

    Slavov, S.; Bakalov, I.; Vassilev, H.

    2001-01-01

    The thermo-hydraulic analyses of the SG box behaviour of Kozloduy NPP units 3 and 4 in case of small primary circuit leaks and during normal operation of the existing ventilation systems in order to determine the detectable leakages from the primary circuit by analysing different parameters used for the purposes of 'Leak before break' concept, performed by ENPRO Consult Ltd. are presented. The following methods for leak detection: measurement of relative air humidity in SG box (can be used for detection of leaks with flow rate 3.78 l/min within one hour at ambient parameters - temperature 40 0 - 60 0 C and relative humidity form 30% to 60%); measurement of water level in SG box sumps (can not be used for reliable detection of small primary circuit leakages with flow rate about 3.78 l/min); measurement of gaseous radioactivity in SG box( can be used as a general global indication for detection of small leakages from the primary circuit); measurement of condensate flow after the air coolers of P-1 venting system (can be used for primary circuit leak detection) are considered. For determination of the confinement behaviour, a model used with computer code MELCOR has been developed by ENPRO Consult Ltd. A brief summary based on the capabilities of the different methods of leak detection, from the point of view of the applicability of a particular method is given. For both Units 3 and 4 of Kozloduy NPP a qualified complex system for small leak detection is planned to be constructed. Such a system has to unite the following systems: acoustic system for leak detection 'ALUS'; system for control of the tightness of the main primary circuit pipelines by monitoring the local humidity; system for primary circuit leakage detection by measuring condensate run-off in collecting tank after ventilation system P-1 air coolers

  13. AirPEx. Air Pollution Exposure Model

    Energy Technology Data Exchange (ETDEWEB)

    Freijer, J.I.; Bloemen, H.J.Th.; De Loos, S.; Marra, M.; Rombout, P.J.A.; Steentjes, G.M.; Van Veen, M.P.

    1997-12-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The principal grounds for studying the inhalatory exposure of humans to air pollutants are formed by the need for realistic exposure/dose estimates to evaluate the health effects of these pollutants. The AirPEx (Air Pollution Exposure) model, developed to assess the time- and space-dependence of inhalatory exposure of humans to air pollution, has been implemented for use as a Windows 3.1 computer program. The program is suited to estimating various exposure and dose quantities for individuals, as well as for populations and subpopulations. This report describes the fundamentals of the AirPEx model and provides a user manual for the computer program. Several examples included in the report illustrate the possibilities of the AirPEx model in exposure assessment. The model will be used at the National Institute of Public Health and the Environment as a tool in analysing the current exposure of the Dutch population to air pollutants. 57 refs.

  14. Impacts of air pollutants on vegetation in developing countries

    CSIR Research Space (South Africa)

    Emberson, LD

    2001-01-01

    Full Text Available The predicted increases in emissions of primary pollutants in many rapidly industrializing countries may have severe consequences for the health and productivity of forest trees and agricultural crops. A review of air pollution and its impact...

  15. EER, COP, and the Second Law Efficiency for Air Conditioners

    Science.gov (United States)

    Leff, Harvey S.; Teeters, William D.

    1978-01-01

    Describes the relationship existing between coefficient of performance (COP) and energy efficiency ratio (EER) in air conditioning units and introduces new efficiency parameters measured relative to the energy extracted from the primary energy source. (SL)

  16. Systematic Evaluation of Aggressive Air Sampling for Bacillus ...

    Science.gov (United States)

    Report The primary objectives of this project were to evaluate the Aggressive Air Sampling (AAS) method compared to currently used surface sampling methods and to determine if AAS is a viable option for sampling Bacillus anthracis spores.

  17. Air corona discharge chemical kinetics

    International Nuclear Information System (INIS)

    Kline, L.E.; Kanter, I.E.

    1984-01-01

    We have theoretically studied the initial chemical processing steps which occur in pulseless, negative, dc corona discharges in flowing air. A rate equation model is used because these discharges consist of a very small ionization zone near the pin with most of the pin-plane gap filled by a drift zone where both the electric field and the electron density are relatively uniform. The primary activated species are N 2 (A),O and O 2 (a 1 Δ). The predicted activated species density due to one discharge is 100 ppm per ms . mA cm 2 assuming E/n=60 Td. In pure, dry air the final product due to these activated species is primarily O 3 . The NO /sub x/ production is about 0.5 ppm per mA. In moist air there is an additional production of about 1.5 ppm per mA of HO /sub x/ species. The predicted ozone formation reactions will be ''intercepted'' when impurities are present in the air. Impurities present at densities below about 0.1% will react primarily with the activated species rather than with electrons. Hence the predicted activated species density provides an estimate of the potential chemical processing performance of the discharge

  18. Speech profile of patients undergoing primary palatoplasty.

    Science.gov (United States)

    Menegueti, Katia Ignacio; Mangilli, Laura Davison; Alonso, Nivaldo; Andrade, Claudia Regina Furquim de

    2017-10-26

    To characterize the profile and speech characteristics of patients undergoing primary palatoplasty in a Brazilian university hospital, considering the time of intervention (early, before two years of age; late, after two years of age). Participants were 97 patients of both genders with cleft palate and/or cleft and lip palate, assigned to the Speech-language Pathology Department, who had been submitted to primary palatoplasty and presented no prior history of speech-language therapy. Patients were divided into two groups: early intervention group (EIG) - 43 patients undergoing primary palatoplasty before 2 years of age and late intervention group (LIG) - 54 patients undergoing primary palatoplasty after 2 years of age. All patients underwent speech-language pathology assessment. The following parameters were assessed: resonance classification, presence of nasal turbulence, presence of weak intraoral air pressure, presence of audible nasal air emission, speech understandability, and compensatory articulation disorder (CAD). At statistical significance level of 5% (p≤0.05), no significant difference was observed between the groups in the following parameters: resonance classification (p=0.067); level of hypernasality (p=0.113), presence of nasal turbulence (p=0.179); presence of weak intraoral air pressure (p=0.152); presence of nasal air emission (p=0.369), and speech understandability (p=0.113). The groups differed with respect to presence of compensatory articulation disorders (p=0.020), with the LIG presenting higher occurrence of altered phonemes. It was possible to assess the general profile and speech characteristics of the study participants. Patients submitted to early primary palatoplasty present better speech profile.

  19. Air pollution and the school air environment

    OpenAIRE

    Fsadni, Peter; Montefort, Stephen

    2015-01-01

    There is growing concern about the association of school indoor air quality (SIAQ) with asthma, rhinitis, and rhinoconjunctivitis. Students and school staff deserve the highest standards of school air quality to ensure a safe and productive environment for our children’s education. Existing studies highlight the presence of several air pollutants present within school classrooms that have a direct association with poor health and poor student performance. Very little data exist ab...

  20. Teaching Air Pollution in an Authentic Context

    Science.gov (United States)

    Mandrikas, Achilleas; Stavrou, Dimitrios; Skordoulis, Constantine

    2017-01-01

    This paper describes a teaching-learning sequence (TLS) about air pollution and the findings resulting from its implementation by pre-service elementary teachers (PET) currently undergraduate students of the Department of Primary Education in the National and Kapodistrian University of Athens, Greece. The TLS focused on the relation of air…

  1. Air quality inside subway metro indoor environment worldwide: A review.

    Science.gov (United States)

    Xu, Bin; Hao, Jinliang

    2017-10-01

    The air quality in the subway metro indoor microenvironment has been of particular public concern. With specific reference to the growing demand of green transportation and sustainable development, subway metro systems have been rapidly developed worldwide in last decades. The number of metro commuters has continuously increased over recent years in metropolitan cities. In some cities, metro system has become the primary public transportation mode. Although commuters typically spend only 30-40min in metros, the air pollutants emitted from various interior components of metro system as well as air pollutants carried by ventilation supply air are significant sources of harmful air pollutants that could lead to unhealthy human exposure. Commuters' exposure to various air pollutants in metro carriages may cause perceivable health risk as reported by many environmental health studies. This review summarizes significant findings in the literature on air quality inside metro indoor environment, including pollutant concentration levels, chemical species, related sources and health risk assessment. More than 160 relevant studies performed across over 20 countries were carefully reviewed. These comprised more than 2000 individual measurement trips. Particulate matters, aromatic hydrocarbons, carbonyls and airborne bacteria have been identified as the primary air pollutants inside metro system. On this basis, future work could focus on investigating the chronic health risks of exposure to various air pollutants other than PM, and/or further developing advanced air purification unit to improve metro in-station air quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. 75 FR 81126 - Revisions to Lead Ambient Air Monitoring Requirements

    Science.gov (United States)

    2010-12-27

    ... tons per year of lead is necessary to provide sufficient information about airborne lead levels near... Revisions to Lead Ambient Air Monitoring Requirements AGENCY: Environmental Protection Agency (EPA). ACTION...) that revised the primary and secondary National Ambient Air Quality Standards (NAAQS) for lead and...

  3. The Interplay of Climate Change and Air Pollution on Health

    OpenAIRE

    Orru, H.; Ebi, K. L.; Forsberg, B.

    2017-01-01

    Purpose of review: Air pollution significantly affects health, causing up to 7 million premature deaths annually with an even larger number of hospitalizations and days of sick leave. Climate change could alter the dispersion of primary pollutants, particularly particulate matter, and intensify the formation of secondary pollutants, such as near-surface ozone. The purpose of the review is to evaluate the recent evidence on the impacts of climate change on air pollution and air pollution-relat...

  4. Position paper -- Tank ventilation system design air flow rates

    International Nuclear Information System (INIS)

    Goolsby, G.K.

    1995-01-01

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems

  5. Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Benton, Nathanael [Nexant, Inc., San Francisco, CA (United States); Burns, Patrick [Nexant, Inc., San Francisco, CA (United States)

    2017-10-18

    Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

  6. The ultimate air shower observatory

    International Nuclear Information System (INIS)

    Jones, L.W.

    1981-01-01

    The possibility of constructing an international air shower observatory in the Himalayas is explored. A site at about 6500 m elevation (450 g/cm 2 ) would provide more definitive measurements of composition and early interaction properties of primaries above 10 16 eV than can be achieved with existing arrays. By supplementing a surface array with a Fly's Eye and muon detectors, information on the highest energy cosmic rays may be gained which is not possible in any other way. Potential sites, technical aspects, and logistical problems are explored

  7. Primary Progressive Aphasia

    Science.gov (United States)

    ... which cause different symptoms. Semantic variant primary progressive aphasia Symptoms include these difficulties: Comprehending spoken or written ... word meanings Naming objects Logopenic variant primary progressive aphasia Symptoms include: Having difficulty retrieving words Frequently pausing ...

  8. Brain tumor - primary - adults

    Science.gov (United States)

    ... Vestibular schwannoma (acoustic neuroma) - adults; Meningioma - adults; Cancer - brain tumor (adults) ... Primary brain tumors include any tumor that starts in the brain. Primary brain tumors can start from brain cells, ...

  9. Primary ovarian malignant melanoma

    Directory of Open Access Journals (Sweden)

    Kostov Miloš

    2010-01-01

    Full Text Available Background. Primary ovarian malignant melanoma is extremely rare. It usually appears in the wall of a dermoid cyst or is associated with another teratomatous component. Metastatic primary malignant melanoma to ovary from a primary melanoma elsewhere is well known and has been often reported especially in autopsy studies. Case report. We presented a case of primary ovarian malignant melanoma in a 45- year old woman, with no evidence of extraovarian primary melanoma nor teratomatous component. The tumor was unilateral, macroscopically on section presented as solid mass, dark brown to black color. Microscopically, tumor cells showed positive immunohistochemical reaction for HMB-45, melan-A and S-100 protein, and negative immunoreactivity for estrogen and progesteron receptors. Conclusion. Differentiate metastatic melanoma from rare primary ovarian malignant melanoma, in some of cases may be a histopathological diagnostic problem. Histopathological diagnosis of primary ovarian malignant melanoma should be confirmed by immunohistochemical analyses and detailed clinical search for an occult primary tumor.

  10. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  11. Investigating Primary Source Literacy

    Science.gov (United States)

    Archer, Joanne; Hanlon, Ann M.; Levine, Jennie A.

    2009-01-01

    Primary source research requires students to acquire specialized research skills. This paper presents results from a user study testing the effectiveness of a Web guide designed to convey the concepts behind "primary source literacy". The study also evaluated students' strengths and weaknesses when conducting primary source research. (Contains 3…

  12. Air conditioning systems to clean radioactive air

    International Nuclear Information System (INIS)

    Ganz, G.

    1987-01-01

    The author reports a study by the Institutes fuer Klimatechnik and Umweltschutz Giessen that shows that air conditioning systems not only make the atmosphere more comfortable, they also extract dust particles. This cleaning action is also valid for radioactively contaminated air. (G.T.H./Auth.)

  13. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative...... and the humidity of the room air. At a low humidity level of 30% an increased velocity could compensate for the decrease in perceived air quality due to an elevated temperature ranging from 20 °C to 26 °C. In a room with 26 °C, increased air movement was also able to compensate for an increase in humidity from 30...... humidity (30, 40 and 70%) and pollution level (low and high). Most of the experiments were performed with and without facially applied airflow at elevated velocity. The importance of the use of recirculated room air and clean, cool and dry outdoor air was studied. The exposures ranged from 60. min to 235...

  14. Simple air collectors for preheating fresh air

    NARCIS (Netherlands)

    Hensen, J.L.M.; Wit, de M.H.; Ouden, den C.

    1984-01-01

    In dwellings with mechanical ventilation systems the fresh air can easily be preheated by means of simple solar air systems. These can be an integral part of the building facade or roof and the costs are expected to be low. By means of computer experiments a large number of systems were evaluated.

  15. Advanced Architectures and Relatives of Air Electrodes in Zn–Air Batteries

    Science.gov (United States)

    Pan, Jing; Xu, Yang Yang; Yang, Huan; Dong, Zehua; Liu, Hongfang

    2018-01-01

    Abstract Zn–air batteries are becoming the promising power sources for portable and wearable electronic devices and hybrid/electric vehicles because of their high specific energy density and the low cost for next‐generation green and sustainable energy technologies. An air electrode integrated with an oxygen electrocatalyst is the most important component and inevitably determines the performance and cost of a Zn–air battery. This article presents exciting advances and challenges related to air electrodes and their relatives. After a brief introduction of the Zn–air battery, the architectures and oxygen electrocatalysts of air electrodes and relevant electrolytes are highlighted in primary and rechargeable types with different configurations, respectively. Moreover, the individual components and major issues of flexible Zn–air batteries are also highlighted, along with the strategies to enhance the battery performance. Finally, a perspective for design, preparation, and assembly of air electrodes is proposed for the future innovations of Zn–air batteries with high performance. PMID:29721418

  16. Air pollution monitoring in downtown Rome, Italy

    Energy Technology Data Exchange (ETDEWEB)

    Brocco, D; Petricca, M; Polesi, R [Consiglio Nazionale delle Ricerche, Rome (Italy). Ist. sull' Inquinamento Atmosferico Assessorato Ambiente, Rome (Italy). Amministrazione Provinciale

    1992-09-01

    This paper tables air pollution data indicating concentrations of sulfur dioxide, nitrous oxides, carbon monoxide, ozone, non-methane hydrocarbons (NMTHC) and particulate matter measured in downtown Rome during the period, April 1990 - March 1991. These data are analyzed according to National Air Quality Standards. Correlations are developed for nitrous oxide, NMTHC and ozone concentration trends as a function of solar radiation intensity. Analysis of the data reveals that the concentrations of the primary pollutants, carbon monoxide and nitrogen oxide, were very high in the winter months when building heating systems were operating under stable weather conditions. In many cases, the concentrations of carbon monoxide exceeded ambient air quality standards. The paper also discusses the need for the development of limits for NMTHC concentrations and including these limits in the Air Quality Standards.

  17. Implementation of the Brazilian primary standard for x-rays

    International Nuclear Information System (INIS)

    Peixoto, J.G.P.; Almeida, C.E.V. de

    2002-01-01

    In the field of ionizing radiation metrology, a primary standard of a given physical quantity is essentially an experimental set-up which allows one to attribute a numerical value to a particular sample of that quantity in terms of a unit given by an abstract definition. The absolute measurement of the radiation quantity air kerma, is performed with a free-air ionization chamber. A great deal of research to determine the absolute measurement resulted in different designs for primary standard free-air ionization chambers such as cilindrics or plane parallel chambers. The implementation of primary standard dosimetry with free-air ionization chambers is limited to the National Metrology Institutes - NMIs. Since 1975, the Bureau International des Poids et Mesures - BIPM has been conducting comparisons of NMIs primary free-air standard chambers in the medium energy x-rays range. These comparisons are carried out indirectly through the calibration at both the BIPM and at the NMI of one or more transfer ionization chambers at a series of four reference radiation qualities. The scientific work programme of the National Laboratory for Ionizing Radiation Metrology - LNMRI of the Institute of Radioprotection and Dosimetry - IRD, which belongs to the National Commission of Nuclear Energy - CNEN, includes the establishment of a primary standard for x-rays of medium energy x-ray range. This activity is justified by the demand to calibrate periodically Brazilian network of the secondary standards without losing quality of the measurement. The LNMRI decided to implement four reference radiation qualities establishing the use of a transfer chamber calibrated at BIPM. The LNMRI decided to implement the primary standard dosimetry using a free-air ionization chamber with variable volume, made by Victoreen, model 480. Parameters related to the measurement of the quantity air kerma were evaluated, such as: air absorption, scattering inside the ionization chamber, saturation, beam

  18. Primary Hyperparathyroidism: An Overview

    Directory of Open Access Journals (Sweden)

    Jessica MacKenzie-Feder

    2011-01-01

    Full Text Available Primary hyperparathyroidism is a common condition that affects 0.3% of the general population. Primary and tertiary care specialists can encounter patients with primary hyperparathyroidism, and prompt recognition and treatment can greatly reduce morbidity and mortality from this disease. In this paper we will review the basic physiology of calcium homeostasis and then consider genetic associations as well as common etiologies and presentations of primary hyperparathyroidism. We will consider emerging trends in detection and measurement of parathyroid hormone as well as available imaging modalities for the parathyroid glands. Surgical indications and approach will be reviewed as well as medical management of primary hyperparathyroidism with bisphosphonates and calcimimetics.

  19. Normocalcemic Primary Hyperparathyroidism

    Science.gov (United States)

    Cusano, Natalie E.; Silverberg, Shonni J.; Bilezikian, John P.

    2013-01-01

    Primary hyperparathyroidism, a common endocrine disorder, is traditionally defined by hypercalcemia and elevated levels of parathyroid hormone (PTH). A newer presentation of primary hyperparathyroidism has been described over the past decade, in which PTH is elevated but serum calcium is consistently normal, in the absence of secondary causes of hyperparathyroidism, such as renal disease or vitamin D deficiency. Recognition of this phenotype of primary hyperparathyroidism, normocalcemic primary hyperparathyroidism, supports a biphasic chronological time course in some individuals in which PTH levels are first elevated but serum calcium is normal, followed by the development of frank hypercalcemia. This review focuses on the available literature regarding this newly described phenotype of primary hyperparathyroidism. PMID:23374739

  20. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Facilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  1. Allegheny County Air Quality

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Air quality data from Allegheny County Health Department monitors throughout the county. Air quality monitored data must be verified by qualified individuals before...

  2. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  3. Lead (Pb) Air Pollution

    Science.gov (United States)

    ... Regional Offices Labs and Research Centers Lead (Pb) Air Pollution Contact Us Share As a result of EPA's ... and protect aquatic and terrestrial ecosystems. Lead (Pb) Air Pollution Basic Information How does lead get in the ...

  4. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  5. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  6. AirCompare

    Data.gov (United States)

    U.S. Environmental Protection Agency — AirCompare contains air quality information that allows a user to compare conditions in different localities over time and compare conditions in the same location at...

  7. Techniques for enhancing durability and equivalence ratio control in a rich-lean, three-stage ground power gas turbine combustor

    Science.gov (United States)

    Schultz, D. F.

    1982-01-01

    Rig tests of a can-type combustor were performed to demonstrate two advanced ground power engine combustor concepts: steam cooled rich-burn combustor primary zones for enhanced durability; and variable combustor geometry for three stage combustion equivalence ratio control. Both concepts proved to be highly successful in achieving their desired objectives. The steam cooling reduced peak liner temperatures to less than 800 K. This offers the potential of both long life and reduced use of strategic materials for liner fabrication. Three degrees of variable geometry were successfully implemented to control airflow distribution within the combustor. One was a variable blade angle axial flow air swirler to control primary airflow while the other two consisted of rotating bands to control secondary and tertiary or dilution air flow.

  8. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  9. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  10. AIR NCO's AND AIRMEN

    African Journals Online (AJOL)

    D.F.C. o Proceeded to Cape Town 9:5:22. Left Cape Town for. African Protectorate 25:2:22. J Left for South West African Protectorate 25:2:22. [ Left for South West African Protectorate. 1:6:22. Colonel: Director of Air Services. Air Directorate. 6th June 1922. SOUTH AFRICAN AIR FORCE. NOMINAL ROLL OF AIR W.O.'s,.

  11. Air Pollution Training Programs.

    Science.gov (United States)

    Public Health Service (DHEW), Rockville, MD.

    This catalog lists the universities, both supported and not supported by the Division of Air Pollution, which offer graduate programs in the field of air pollution. The catalog briefly describes the programs and their entrance requirements, the requirements, qualifications and terms of special fellowships offered by the Division of Air Pollution.…

  12. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.

  13. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  14. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  15. Air quality and disease

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Climate change is an important determinant of air quality. Climate change is an important determinant of air quality. Poor air quality associated with higher levels of respiratory and cardiovascular disease. Exposure to high levels of ground-level ozone associated with ...

  16. Air Force Leadership Diversity

    Science.gov (United States)

    2017-04-06

    served as a deputy maintenance group commander. Following Air War College he will take command of the 8th Maintenance Group, Kunsan Air Base, Korea ...discrimination in terms of 3 race, religion , sex, etc.: the demographics we have all heard about for years. Air Force Policy Directive (AFPD) 36

  17. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  18. Air Pollution and Its Effects on an Individual's Health and Exercise Performance.

    Science.gov (United States)

    Singh, A. I. Clifford

    1988-01-01

    Air Pollution is a common environmental stressor affecting the training and competitive performance of athletes, commonly irritating the eyes, nose, and throat. The health and exercise effects of such primary and secondary air pollutants as carbon monoxide, sulfur dioxide, air particulates, ozone, and nitrogen dioxide are discussed. (CB)

  19. 75 FR 32293 - Revisions to the California State Implementation Plan, South Coast Air Quality Management District

    Science.gov (United States)

    2010-06-08

    ... the California State Implementation Plan, South Coast Air Quality Management District AGENCY... approve revisions to the South Coast Air Quality Management District (SCAQMD) portion of the California... submit regulations that control the primary and secondary National Ambient Air Quality Standards (NAAQS...

  20. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  1. Photochemical air pollution

    International Nuclear Information System (INIS)

    Te Winkel, B.H.

    1992-01-01

    During periods of severe photochemical air pollution (smog) the industry in the Netherlands is recommended by the Dutch government to strongly reduce the emissions of air pollutants. For the electric power generating companies it is important to investigate the adequacy of this policy. The purpose of this investigation is to determine the contribution of electric power plants to photochemical air pollution and to assess the efficacy of emission reducing measures. A literature survey on the development of photochemical air pollution was carried out and modelled calculations concerning the share of the electric power plants to the photochemical air pollution were executed

  2. Air-water screen

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.I.; Kutepov, A.I.

    1980-12-08

    The air-water screen based on inventor's certificate No. 577364 contains horizontal water and air lines with water and air nozzles. The air line is situated inside the water line eccentrically and contracts it in the area of the nozzle, whose orifices are situated along the line of contact, while the orifices of the water nozzle are situated symmetrically relative to the air orifices and are located at an acute angle to them. To raise the protective properties, on the end of the water line is a lateral nozzle water distributor is an additional nozzle, connected to this container.

  3. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  4. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  5. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  6. Health Effects of Air Pollution

    Science.gov (United States)

    ... Health effects of air pollution Health effects of air pollution Breathing air that is not clean can hurt ... important to know about the health effects that air pollution can have on you and others. Once you ...

  7. Liberalisation of air cargo transport

    Science.gov (United States)

    2002-05-02

    Over a period of many years, international air cargo demand has continued to increase more rapidly than international air passenger demand. Air cargo arrangements need to be as efficient and expeditious as possible, to meet user requirements for air ...

  8. Multiple primary cancer

    International Nuclear Information System (INIS)

    Jung, Gyu Sik; Lee, Ouk; Kim, So Sun; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    It is rare for one human being to be afflicted with more than one cancer. However with further advances in therapeutic regimens, histopathologic observation, diagnostic modalities, and increased curiosity, there are increasing number of case reports of multiple primary cancer. The present study evaluates 25 histologically confirmed cases of multiple primary cancer from 1974 to 1988 at Kosin Medical Center. The most frequent site of the first primary cancer in male was stomach and in female, uterine cervix. The first primary cancer in female occurred in endocrine-related organs (breast, uterus and thyroid) in 63.6 percent. Synchronous cancers are diagnosed simultaneously or within an interval of about six months and synchronous cancers were 16 out of 25 cases. Metachronous cancers are diagnosed at interval of more than six months. There were 9 metachronous cancers and average interval between the first and second primary cancer was 22.8 months. The incidence of multiple primary cancer was 0.11 percent. The average age was 51.9 years at the time of the first primary cancer (53.1 years in male and 50.3 years in female). CT scan was most helpful in early detection of multiple primary cancers facilitating biopsy and surgery. Multiple primary cancers are beyond the medical curiosity. Early diagnosis of the disease and careful follow-up study, based on an awareness of the possibility of second cancers, will substantially increase the survival of these patients

  9. Released air during vapor and air cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz [VŠB-Technical University of Ostrava, Faculty of Mechanical Engineering, Department of Hydromechanics and Hydraulic Equipment, 17. listopadu 15, 708 33 Ostrava-Poruba (Czech Republic)

    2016-06-30

    Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

  10. Local Air Quality Conditions and Forecasts

    Science.gov (United States)

    ... Monitor Location Archived Maps by Region Canada Air Quality Air Quality on Google Earth Links A-Z About AirNow AirNow International Air Quality Action Days / Alerts AirCompare Air Quality Index (AQI) ...

  11. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  12. Using Primary Source Documents.

    Science.gov (United States)

    Mintz, Steven

    2003-01-01

    Explores the use of primary sources when teaching about U.S. slavery. Includes primary sources from the Gilder Lehrman Documents Collection (New York Historical Society) to teach about the role of slaves in the Revolutionary War, such as a proclamation from Lord Dunmore offering freedom to slaves who joined his army. (CMK)

  13. Medics in Primary School

    Science.gov (United States)

    Press, Colin

    2003-01-01

    Some time ago a flyer on "Medics in Primary School" came the author's way. It described a programme for making placements in primary schools available to medical students. The benefits of the program to medical students and participating schools were highlighted, including opportunities to develop communication skills and demystify…

  14. Air pollution episodes in Stockholm regional background air due to sources in Europe and their effects on human population

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, C. [Swedish Meteorological and Hydrological Inst., Norrkoping (Sweden)], E-mail: camilla.andersson@smhi.se; Joensson, O. [Stockholm Univ. (Sweden). Dept. of Applied Environmental Science; Forsberg, B. [Umea Univ. (Sweden), Occupational and Environmental Medicine; Johansson, C. [Environmental and Health Administration, Stockholm (Sweden)

    2013-09-01

    Using air quality measurements, we categorized air pollution according to source sectors in a rural background environment in southern Sweden based on hourly air-mass backward trajectories during 1997-2010. Concentrations of fine (PM{sub 2.5}) and sum of fine and coarse particulate matter (PM{sub 10}), accumulation mode particle number, black carbon and surface ozone were 4.0, 3.9, 4.5, 6.8 and 1.3 times higher, respectively, in air masses from the southeast as compared with those in air masses from the cleanest sector in the northwest, consistent with air-mass transport over areas with relatively high emissions of primary particulate matter (PM) and secondary PM precursors. The highest ultrafine particle numbers were associated with clean air from the northwest. We estimate that almost 7.8% and 0.6% higher premature human mortality is caused by PM{sub 2.5} and ozone exposure, respectively, when air originates from the southeast as compared with that when air originates from the northwest. Reductions of emissions in eastern Europe would reduce the highest air pollution concentrations and associated health risks. However, since air masses from the southwest are more frequent, emissions in the western part of Europe are more important for annual mean premature mortality. (orig.)

  15. Comparing Spray Characteristics from Reynolds Averaged Navier-Stokes (RANS) National Combustion Code (NCC) Calculations Against Experimental Data for a Turbulent Reacting Flow

    Science.gov (United States)

    Iannetti, Anthony C.; Moder, Jeffery P.

    2010-01-01

    Developing physics-based tools to aid in reducing harmful combustion emissions, like Nitrogen Oxides (NOx), Carbon Monoxide (CO), Unburnt Hydrocarbons (UHC s), and Sulfur Dioxides (SOx), is an important goal of aeronautics research at NASA. As part of that effort, NASA Glenn Research Center is performing a detailed assessment and validation of an in-house combustion CFD code known as the National Combustion Code (NCC) for turbulent reacting flows. To assess the current capabilities of NCC for simulating turbulent reacting flows with liquid jet fuel injection, a set of Single Swirler Lean Direct Injection (LDI) experiments performed at the University of Cincinnati was chosen as an initial validation data set. This Jet-A/air combustion experiment operates at a lean equivalence ratio of 0.75 at atmospheric pressure and has a 4 percent static pressure drop across the swirler. Detailed comparisons of NCC predictions for gas temperature and gaseous emissions (CO and NOx) against this experiment are considered in a previous work. The current paper is focused on detailed comparisons of the spray characteristics (radial profiles of drop size distribution and at several radial rakes) from NCC simulations against the experimental data. Comparisons against experimental data show that the use of the correlation for primary spray break-up implemented by Raju in the NCC produces most realistic results, but this result needs to be improved. Given the single or ten step chemical kinetics models, use of a spray size correlation gives similar, acceptable results

  16. Feedback linearization based control of a variable air volume air conditioning system for cooling applications.

    Science.gov (United States)

    Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik

    2008-07-01

    Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.

  17. Bad traffic, bad air

    OpenAIRE

    Duca, Edward

    2012-01-01

    Air pollution is one of Malta’s greatest concerns. Transportation is the principal source with over 300,000 vehicles belching out smoke, which damages our environment and health. Emissions from vehicles need to be monitored and controlled, and the information used to improve the current system and ensure an acceptable air quality. By using the pollution data set, Nicolette Formosa (supervised by Dr Kenneth Scerri) mapped the air pollution levels and major sources around Malta. http://www....

  18. Radioactive material air transportation

    International Nuclear Information System (INIS)

    Pader y Terry, Claudio Cosme

    2002-01-01

    As function of the high aggregated value, safety regulations and the useful life time, the air transportation has been used more regularly because is fast, reliable, and by giving great security to the cargo. Based on the International Atomic Energy Agency (IAEA), the IATA (International Air Transportation Association) has reproduced in his dangerous goods manual (Dangerous Goods Regulations - DGR IATA), the regulation for the radioactive material air transportation. Those documents support this presentation

  19. Effect of aviation fuel type and fuel injection conditions on the spray characteristics of pressure swirl and hybrid air blast fuel injectors

    Science.gov (United States)

    Feddema, Rick

    fuels. Optical patternation data and line of sight laser diffraction data show that there is significant difference between jet fuels. Particularly at low fuel injection pressures (0.345 MPa) and cold temperatures (-40 C), the patternation data shows that the total surface area in the spray at 38.1 mm from the pressure swirl injector for the JP-10 fuel type is one-sixth the amount of the JP-8. Finally, this study compares the atomizer performance of a pressure swirl nozzle to a hybrid air blast nozzle. The total surface area for both the hybrid air blast nozzle and the pressure swirl nozzle show a similar decline in atomization performance at low fuel injection pressures and cold temperatures. However, the optical patternator radial profile data and the line of sight laser diffraction data show that the droplet size and spray distribution data are less affected by injection conditions and fuel type in the hybrid air blast nozzle, than they are in the pressure swirl nozzle. One explanation is that the aerodynamic forces associated with the swirler on the hybrid air blast nozzle control the distribution droplets in the spray. This is in contrast to the pressure swirl nozzle droplet distribution that is controlled by internal geometry and droplet ballistics.

  20. Air pollution engineering

    Science.gov (United States)

    Maduna, Karolina; Tomašić, Vesna

    2017-11-01

    Air pollution is an environmental and a social problem which leads to a multitude of adverse effects on human health and standard of human life, state of the ecosystems and global change of climate. Air pollutants are emitted from natural, but mostly from anthropogenic sources and may be transported over long distances. Some air pollutants are extremely stable in the atmosphere and may accumulate in the environment and in the food chain, affecting human beings, animals and natural biodiversity. Obviously, air pollution is a complex problem that poses multiple challenges in terms of management and abatements of the pollutants emission. Effective approach to the problems of air pollution requires a good understanding of the sources that cause it, knowledge of air quality status and future trends as well as its impact on humans and ecosystems. This chapter deals with the complexities of the air pollution and presents an overview of different technical processes and equipment for air pollution control, as well as basic principles of their work. The problems of air protection as well as protection of other ecosystems can be solved only by the coordinated endeavors of various scientific and engineering disciplines, such as chemistry, physics, biology, medicine, chemical engineering and social sciences. The most important engineering contribution is mostly focused on development, design and operation of equipment for the abatement of harmful emissions into environment.

  1. Applications Using AIRS Data

    Science.gov (United States)

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  2. Air University Press Publications

    National Research Council Canada - National Science Library

    2002-01-01

    .... Our publications program is designed primarily to help Air Force and other US war fighters, national leaders and policy makers, academicians, military historians, and other analysts understand...

  3. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  4. Air pollution meteorology

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Daoo, V J [Environmental Assessment Div., Bhabha Atomic Research Centre, Mumbai (India)

    2002-06-01

    This report is intended as a training cum reference document for scientists posted at the Environmental Laboratories at the Nuclear Power Station Sites and other sites of the Department of Atomic Energy with installations emitting air pollutants, radioactive or otherwise. Since a manual already exists for the computation of doses from radioactive air pollutants, a general approach is take here i.e. air pollutants in general are considered. The first chapter presents a brief introduction to the need and scope of air pollution dispersion modelling. The second chapter is a very important chapter discussing the aspects of meteorology relevant to air pollution and dispersion modelling. This chapter is important because without this information one really does not understand the phenomena affecting dispersion, the scope and applicability of various models or their limitations under various weather and site conditions. The third chapter discusses the air pollution models in detail. These models are applicable to distances of a few tens of kilometres. The fourth chapter discusses the various aspects of meteorological measurements relevant to air pollution. The chapters are followed by two appendices. Apendix A discusses the reliability of air pollution estimates. Apendix B gives some practical examples relevant to general air pollution. It is hoped that the document will prove very useful to the users. (author)

  5. Pulse triggering mechanism of air proportional counters

    International Nuclear Information System (INIS)

    Aoyama, T.; Mori, T.; Watanabe, T.

    1983-01-01

    This paper describes the pulse triggering mechanism of a cylindrical proportional counter filled with air at atmospheric pressure for the incidence of β-rays. Experimental results indicate that primary electrons created distantly from the anode wire by a β-ray are transformed into negative ions, which then detach electrons close to the anode wire and generate electron avalanches thus triggering pulses, while electrons created near the anode wire by a β-ray directly trigger a pulse. Since a negative ion pulse is triggered by a single electron detached from a negative ion, multiple pulses are generated by a large number of ions produced by the incidence of a single β-ray. It is therefore necessary not to count pulses triggered by negative ions but to count those by primary electrons alone when use is made of air proportional counters for the detection of β-rays. (orig.)

  6. CT findings in primary pulmonary lymphomas

    International Nuclear Information System (INIS)

    Cardinale, Luciano; Allasia, Marco; Cataldi, Aldo; Ferraris, Fabrizio; Fava, Cesare; Parvis, Guido

    2005-01-01

    Purpose. To describe the CT findings of pathologically confirmed primary pulmonary lymphomas. Materials and methods. The CT examinations of 11 patients with pathologically proven primary pulmonary lymphoma (9 BALT lymphomas and 2 non-BALT lymphomas) were retrospectively reviewed by three radiologists. Evaluated findings included morphology (consolidation, mass, nodule), number and distribution of lesions. Other CT findings such as air bronchogram, lymphadenopathy atelectasis and pleural effusion were also assessed. Results. Pulmonary lesions were depicted as air-space consolidation (pneumonia-like) in 5 patients (45%), tumour-like rounded opacity in 4 (36%), and nodules in 4 (36%). Multiple and bilateral long lesions were seen in 3 patients (27%). Air bronchogram was present in 7 patients (63%), lymphadenopathy in 3 (27%), atelectasis in 4 (36%) and pleural effusion in only 1 (9%). Conclusions. Our results agree with previous studies regarding lesion patterns and their relative frequency. A smaller number of nodules and of multiple lesions were found compared with some previous studies. The most frequent pattern was airspace consolidation [it

  7. RadNet Radiological Air Monitoring Network

    International Nuclear Information System (INIS)

    Scott Telofski, J.; Askren, D.R.; Petko, Ch.M.; Fraass, R.G.

    2010-01-01

    The United States Environmental Protection Agency operates a national environmental radiation monitoring program called RadNet. RadNet monitors airborne particulates, precipitation, milk, and drinking water for radiation levels. The primary purpose of the original program in the 1950's and 1960's was to collect and analyze samples in various media to assess the effects of radioactive fallout from above-ground nuclear weapon testing. As above-ground testing diminished in the 1970's, the program, especially the air network, became critical in evaluating effects of other types of nuclear incidents, such as the nuclear reactor accident at Chernobyl, as well as monitoring trends in environmental radioactive contamination. The value of rapid data collection subsequent to such incidents led to the consideration of developing air monitors with radiation detectors and telecommunication equipment for real-time radiation measurement. The strengthened United States homeland security posture after 2001 led to production and installation of the current real-time RadNet air monitors. There are now 118 stationary, continuously operating air monitoring stations and 40 mobile air monitors for site specific monitoring. The stationary air monitors include radiation detectors, meteorological sensors, a high-volume air sampler, and communication devices for hourly data transfers. When unusual levels are detected, scientists download a full sodium iodide detector spectrum for analysis. The real-time data collected by RadNet stationary systems permit rapid identification and quantification of airborne nuclides with sufficient sensitivity to provide critical information to help determine protective actions. The data also may help to rapidly refine long-range radioactive plume models and estimate exposure to the population. This paper provides an overview of the airborne particulate monitoring conducted during above-ground nuclear weapon testing, summarizes the uses of data from the program

  8. Cosmic radiation and air crew exposure

    International Nuclear Information System (INIS)

    Vukovic, B.; Lisjak, I.; Vekic, B.; Planinic, J.

    2005-01-01

    When the primary particles from space, mainly protons, enter the atmosphere, they interact with the air nuclei and induce cosmic-ray shower. When an aircraft is in the air, the radiation field within includes many types of radiation of large energy range; the field comprises mainly photons, electrons, positrons and neutrons. Cosmic radiation dose for crews of air crafts A 320 and ATR 42 was measured using TLD-100 (LiF: Mg, Ti) detectors and the Mini 6100 semiconductor dosimeter; radon concentration in the atmosphere was measured using the Alpha Guard radon detector. The total annual dose estimated for the A 320 aircraft crew, at altitudes up to 12000 meters, was 5.3 mSv (including natural radon radiation dose of 1.1 mSv).(author)

  9. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    Science.gov (United States)

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  10. Primary Sclerosing Cholangitis (PSC)

    Science.gov (United States)

    ... Legacy Society Make Gifts of Stock Donate Your Car Personal Fundraising Partnership & Support Share Your Story Spread the Word Give While You Shop Contact Us Donate Now Primary Sclerosing Cholangitis Back ...

  11. Primary cultures of astrocytes

    DEFF Research Database (Denmark)

    Lange, Sofie C; Bak, Lasse Kristoffer; Waagepetersen, Helle S

    2012-01-01

    During the past few decades of astrocyte research it has become increasingly clear that astrocytes have taken a central position in all central nervous system activities. Much of our new understanding of astrocytes has been derived from studies conducted with primary cultures of astrocytes...... subsequently found in vivo. Nevertheless, primary cultures of astrocytes are an in vitro model that does not fully mimic the complex events occurring in vivo. Here we present an overview of the numerous contributions generated by the use of primary astrocyte cultures to uncover the diverse functions...... of astrocytes. Many of these discoveries would not have been possible to achieve without the use of astrocyte cultures. Additionally, we address and discuss the concerns that have been raised regarding the use of primary cultures of astrocytes as an experimental model system....

  12. Primary Meningeal Rhabdomyosarcoma

    Science.gov (United States)

    Palta, Manisha; Riedel, Richard F.; Vredenburgh, James J.; Cummings, Thomas J.; Green, Scott; Chang, Zheng; Kirkpatrick, John P.

    2011-01-01

    Primary meningeal rhabdomyosarcoma is a rare primary brain malignancy, with scant case reports. While most reports of primary intracranial rhabdomyosarcoma occur in pediatric patients, a handful of cases in adult patients have been reported in the medical literature. We report the case of a 44-year-old male who developed primary meningeal rhabdomyosarcoma. After developing episodes of right lower extremity weakness, word finding difficulty, and headaches, a brain magnetic resonance imaging (MRI) demonstrated a vertex lesion with radiographic appearance of a meningeal-derived tumor. Subtotal surgical resection was performed due to sagittal sinus invasion and initial pathology was interpreted as an anaplastic meningioma. Re-review of pathology demonstrated rhabdomyosarcoma negative for alveolar translocation t(2;13). Staging studies revealed no evidence of disseminated disease. He was treated with stereotactic radiotherapy with concurrent temozolamide to be followed by vincristine, actinomycin-D, and cyclophosphamide (VAC) systemic therapy. PMID:21772793

  13. Primary Meningeal Rhabdomyosarcoma

    Directory of Open Access Journals (Sweden)

    Manisha Palta

    2011-01-01

    Full Text Available Primary meningeal rhabdomyosarcoma is a rare primary brain malignancy, with scant case reports. While most reports of primary intracranial rhabdomyosarcoma occur in pediatric patients, a handful of cases in adult patients have been reported in the medical literature. We report the case of a 44-year-old male who developed primary meningeal rhabdomyosarcoma. After developing episodes of right lower extremity weakness, word finding difficulty, and headaches, a brain magnetic resonance imaging (MRI demonstrated a vertex lesion with radiographic appearance of a meningeal-derived tumor. Subtotal surgical resection was performed due to sagittal sinus invasion and initial pathology was interpreted as an anaplastic meningioma. Re-review of pathology demonstrated rhabdomyosarcoma negative for alveolar translocation t(2;13. Staging studies revealed no evidence of disseminated disease. He was treated with stereotactic radiotherapy with concurrent temozolamide to be followed by vincristine, actinomycin-D, and cyclophosphamide (VAC systemic therapy.

  14. Primary meningeal rhabdomyosarcoma.

    Science.gov (United States)

    Palta, Manisha; Riedel, Richard F; Vredenburgh, James J; Cummings, Thomas J; Green, Scott; Chang, Zheng; Kirkpatrick, John P

    2011-01-01

    Primary meningeal rhabdomyosarcoma is a rare primary brain malignancy, with scant case reports. While most reports of primary intracranial rhabdomyosarcoma occur in pediatric patients, a handful of cases in adult patients have been reported in the medical literature. We report the case of a 44-year-old male who developed primary meningeal rhabdomyosarcoma. After developing episodes of right lower extremity weakness, word finding difficulty, and headaches, a brain magnetic resonance imaging (MRI) demonstrated a vertex lesion with radiographic appearance of a meningeal-derived tumor. Subtotal surgical resection was performed due to sagittal sinus invasion and initial pathology was interpreted as an anaplastic meningioma. Re-review of pathology demonstrated rhabdomyosarcoma negative for alveolar translocation t(2;13). Staging studies revealed no evidence of disseminated disease. He was treated with stereotactic radiotherapy with concurrent temozolamide to be followed by vincristine, actinomycin-D, and cyclophosphamide (VAC) systemic therapy.

  15. Primary Nurse - Role Evolution

    Science.gov (United States)

    Mundinger, Mary O'Neil

    1973-01-01

    Primary nursing means that each patient has an individual nurse who is responsible for assessing his nursing needs and planning and evaluating his nursing care. The article describes the advantages and problems connected with this approach to patient care. (AG)

  16. Multiple Primary Tumors

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Multiple primary tumors occur in clinical practice causing diagnostic dilemma. It is not very .... was estrogen receptor negative, progesterone receptor negative, and ... cervical, ovarian, and urinary bladder cancers. Multiple.

  17. Primary infertility (image)

    Science.gov (United States)

    Primary infertility is a term used to describe a couple that has never been able to conceive a pregnancy ... to do so through unprotected intercourse. Causes of infertility include a wide range of physical as well ...

  18. Primary Intraorbital Ectopic Meningioma

    Science.gov (United States)

    Yokoyama, Tetsuo; Nishizawa, Shigeru; Sugiyama, Kenji; Yokota, Noki; Ohta, Seiji; Uemura, Kenichi; Hinokuma, Kaoru; Inenaga, Chikanori

    1999-01-01

    We report a case of intraorbital meningioma. Operative findings and histopathological examination revealed the tumoc to be meningothelial meningloma and to be located entirely outside the optic dura. This case demonstrates the occurrence of primary intraorbital ectopic meningioma, and the tumor was removed through a modified Dolenc approach. The primary intraorbital ectopic meningioma is discussed and the surgical approach to the orbital apex region is reviewed. ImagesFigure 1Figure 2Figure 4Figure 5 PMID:17171081

  19. Primary leiomyosarcoma of epididymis

    Directory of Open Access Journals (Sweden)

    Dillip Kumar Muduly

    2012-01-01

    Full Text Available Primary leiomyosarcomas rarely arise from epididymis. But they are the most common histopathological types of sarcoma arising from the epididymis. Primary epididymal leiomyosarcoma occurs usually in older patients. We report a young patient of 35 years presenting with leiomyosarcoma of left epididymis. He did not have any metastasis and underwent left high inguinal orchiectomy. He is on regular follow-up and disease free for last two years.

  20. Primary care ... where?

    Science.gov (United States)

    Adcock, G B

    1999-07-01

    Corporate-based nurse managed centers are not the national norm. More prevalent is the use of an occupational health or physician-directed medical model of care. The author describes how a 14-year-old primary care center at a North Carolina computer software company is just "business as usual" when viewed in the context of the company's philosophy, goals, and culture. Included are considerations for nurse practitioners interested in the successful transplantation of this primary care model to other settings.

  1. Solar air-conditioning. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    Within the 3rd International Conference on solar air-conditioning in Palermo (Italy) at 30th September to 2nd October, 2009 the following lectures were held: (1) Removal of non-technological barriers to solar cooling technology across Southern European islands (Stefano Rugginenti); (2) The added economic and environmental value of solar thermal systems in microgrids with combined heat and power (Chris Marney); (3) Australian solar cooling interest group (Paul Kohlenbach); (4) Designing of a technology roadmap for solar assisted air conditioning in Austria (Hilbert Focke); (5) Solar cooling in the new context of renewable policies at European level (Raffaele Piria); (6) Prototype of a solar driven steam jet ejector chiller (Clemens Pollerberg); (7) New integrated solar air conditioning system (Joan Carlos Bruno); (8) Primary energy optimised operation of solar driven desiccant evaporative cooling systems through innovative control strategies; (9) Green chiller association (Uli Jakob); (10) Climate Well {sup registered} (Olof Hallstrom); (11) Low capacity absorption chillers for solar cooling applications (Gregor Weidner); (12) Solar cooling in residential, small scale commercial and industrial applications with adsorption technology (Walter Mittelbach); (13) French solar heating and cooling development programme based on energy performance (Daniel Mugnier); (14) Mirrox fresnel process heat collectors for industrial applications and solar cooling (Christian Zahler); (15) Modelling and analyzing solar cooling systems in polysun (Seyen Hossein Rezaei); (16) Solar cooling application in Valle Susa Italy (Sufia Jung); (17) Virtual case study on small solar cooling systems within the SolarCombi+Project (Bjoern Nienborg); (18) Design of solar cooling plants under uncertainty (Fernando Dominguez-Munoz); (19) Fast pre-design of systems using solar thermally driven chillers (Hans-Martin Henning); (20) Design of a high fraction solar heating and cooling plant in southern

  2. Maxwell Air Force Base

    Science.gov (United States)

    most effective style of leadership. (Courtesy Photo, Air University Press) Air University Press Directory Maxwell Links Welcome Leadership Joint Land Use Study Heritage Pamphlet Maxwell Driving Tour (No releases 'A Discourse on Winning and Losing' "Developing Your Full Range of Leadership" focuses

  3. Energy and air quality

    International Nuclear Information System (INIS)

    1981-12-01

    This is one of a series of handbooks designed to provide nontechnical readers with a general understanding of the interaction between energy development and environmental media and to provide a rudimentary data base from which estimates of potential future impacts can be made. This handbook describes the air quality impacts of energy development and summarizes the major federal legislation which regulates the potential air quality impacts of energy facilities and can thus influence the locations and timing of energy development. In addition, this report describes and presents the data which can be used as the basis for measurement, and in some cases, prediction of the potential conflicts between energy development and achieving and maintaining clean air. Energy utilization is the largest emission source of man-made air pollutants. Choices in energy resource development and utilization generate varying emissions or discharges into the atmosphere, the emissions are affected by the assimilative character of the atmosphere, and the resultant air pollutant concentrations have biological and aesthetic effects. This handbook describes the interrelationships of energy-related air emissions under various methods of pollution control, the assimilative character of the air medium, and the effects of air pollution. The media book is divided into three major sections: topics of concern relating to the media and energy development, descriptions of how to use available data to quantify and examine energy/environmental impacts, and the data

  4. Paradoxical cerebral air embolism

    International Nuclear Information System (INIS)

    Lopez-Negrete, L.; Garcia-Lozano, J.; Sanchez, J. L.; Sala, J.

    2000-01-01

    We present a fatal case of intracranial air embolism produced by the passage of intravenous air to the arteries owing to the existence of a patent foremen ovale associated with pulmonary hypertension, which permitted a right-left shunt (paradoxical embolism). The pathophysiological mechanisms of pneumcephalus and paradoxical embolism are discussed and the pertinent literature is reviewed. (Author) 6 refs

  5. Dioxin in Danish air

    Energy Technology Data Exchange (ETDEWEB)

    Vikelsoe, J.; Andersen, H.V. [National Environmental Research Inst., Roskilde (Denmark)

    2004-09-15

    To gain more knowledge about dioxin levels, sources and emissions in Denmark, the Danish government year 2001 initiated the Danish Dioxin Monitoring Program. The program is a series of investigations, comprising soil, compost, percolate, bio-ash, incineration of municipal and hazardous waste, deposition, air, lake and fjord sediment as well as cows milk and human milk. The present paper describes the preliminary results for the continued investigation of air. Deposition of dioxin over land or sea is of major importance for the human exposure, which takes place mainly from food intake. The dioxin are emitted mainly to the atmosphere, therefore air measurements are well suited for tracking the transport and fate of dioxin from sources to exposure. Whereas measurements from chimneys has been frequently used to estimate the industrial emission from point sources such as incinerators, air measurements also include emission from diffuse sources such as larger urban or industrial regions, residential quarters, and from evaporation. Furthermore, emission measurements must be done on known sources, whereas air measurements include contribution from unknown source. The major drawbacks of air measurements are the long duration required (years), and the results depends on meteorological conditions, such as temperature, rainfall, wind speed and direction. The purpose of the present study has been to measure dioxins in Danish air, emphasizing - background concentrations and annual variation - difference between urban, rural and residential zones - influence from local sources and long range transport - connection between dioxin in air and deposition.

  6. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  7. AIR RADIOACTIVITY MONITOR

    Science.gov (United States)

    Bradshaw, R.L.; Thomas, J.W.

    1961-04-11

    The monitor is designed to minimize undesirable background buildup. It consists of an elongated column containing peripheral electrodes in a central portion of the column, and conduits directing an axial flow of radioactively contaminated air through the center of the column and pure air through the annular portion of the column about the electrodes. (AEC)

  8. Air Pollution and Industry.

    Science.gov (United States)

    Ross, R. D., Ed.

    This book is an authoritative reference and practical guide designed to help the plant engineer identify and solve industrial air pollution problems in order to be able to meet current air pollution regulations. Prepared under the editorial supervision of an experienced chemical engineer, with each chapter contributed by an expert in his field,…

  9. Transportation and air quality

    International Nuclear Information System (INIS)

    Roseland, M.

    1992-01-01

    In the greater Vancouver regional district (GVRD), some 80% of the annual production of 600,000 tonnes of air pollutants come from motor vehicles. Three critical air quality issues in the GVRD are discussed: local air pollution, ozone layer depletion, and greenhouse gas emissions, all of which are fundamentally linked to transportation. Overall air quality in the GVRD has been judged acceptable by current federal standards, but ground-level ozone has exceeded maximum tolerable levels at some locations and concentrations of suspended particulates are above maximum acceptable levels. Serious deterioration in air quality has been predicted unless a concerted effort is made to manage air quality on an airshed-wide basis. The GVRD is developing Canada's first Air Management Plan with the goal of halving atmospheric emissions by 2000. GVRD transportation priorities stress public transit, walking, cycling, car pooling, and reducing of travel demand; however, the viability of such strategies depends on decisions made outside the transportation sector. Restricted authority and jurisdiction also hinder GVRD goals; the regional level of government has no authority over highways or transit and only has authority for pollution control in some parts of the Fraser Valley. Airshed quality management, using the Los Angeles example, is seen as a possible direction for future GVRD policymaking in the transportation sector. A single regional planning agency with responsibility for transportation, land use, and air quality management appears as the best option for an integrated approach to solve multiple problems. 19 refs

  10. Over the air test

    DEFF Research Database (Denmark)

    2015-01-01

    [1] This invention relates to over-the-air testing of a device in an anechoic chamber. In particular, the invention is suitable for simulating both uplink and downlink over-the-air communication with a device under test even when the anechoic chamber has different numbers of uplink and downlink...

  11. Recirculating electric air filter

    Science.gov (United States)

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  12. Air Pollution Primer.

    Science.gov (United States)

    National Tuberculosis and Respiratory Disease Association, New York, NY.

    As the dangers of polluted air to the health and welfare of all individuals became increasingly evident and as the complexity of the causes made responsibility for solutions even more difficult to fix, the National Tuberculosis and Respiratory Disease Association felt obligated to give greater emphasis to its clean air program. To this end they…

  13. Air Force Senior Leaders

    Science.gov (United States)

    Force TV Radio Week in Photos About Us Air Force Senior Leaders SECAF CSAF CMSAF Biographies Adjunct Professors Senior Mentor Biographies Fact Sheets Commander's Call Topics CCT Archive CSAF Reading List 2017 Media Sites Site Registration Contact Us Search AF.mil: Home > About Us > Air Force Senior Leaders

  14. Air Layer Drag Reduction

    Science.gov (United States)

    Ceccio, Steven; Elbing, Brian; Winkel, Eric; Dowling, David; Perlin, Marc

    2008-11-01

    A set of experiments have been conducted at the US Navy's Large Cavitation Channel to investigate skin-friction drag reduction with the injection of air into a high Reynolds number turbulent boundary layer. Testing was performed on a 12.9 m long flat-plate test model with the surface hydraulically smooth and fully rough at downstream-distance-based Reynolds numbers to 220 million and at speeds to 20 m/s. Local skin-friction, near-wall bulk void fraction, and near-wall bubble imaging were monitored along the length of the model. The instrument suite was used to access the requirements necessary to achieve air layer drag reduction (ALDR). Injection of air over a wide range of air fluxes showed that three drag reduction regimes exist when injecting air; (1) bubble drag reduction that has poor downstream persistence, (2) a transitional regime with a steep rise in drag reduction, and (3) ALDR regime where the drag reduction plateaus at 90% ± 10% over the entire model length with large void fractions in the near-wall region. These investigations revealed several requirements for ALDR including; sufficient volumetric air fluxes that increase approximately with the square of the free-stream speed, slightly higher air fluxes are needed when the surface tension is reduced, higher air fluxes are required for rough surfaces, and the formation of ALDR is sensitive to the inlet condition.

  15. Restoran Buenos Aires = Restaurant Buenos Aires

    Index Scriptorium Estoniae

    2008-01-01

    Restorani Buenos Aires (Narva mnt. 5, Tallinn) sisekujundusest. Sisearhitektid: Janno Roos ja Andres Labi (Ruumilabor OÜ). Laudu eraldavad 400 vardasse aetud puukuuli. Sisearhitektidest, nende tähtsamad tööd. I-III korruse plaan, 12 värv. vaadet, fotod sisearhitektidest

  16. The effect of orifice plate insertion on low NOx radial swirl burner performances (simulated variable area burner)

    International Nuclear Information System (INIS)

    Mohammad Nazri Mohd Jaafar

    2000-01-01

    The effect of inserting an outlet orifice plate of different sizes at the exit plane of the swirler outlet were studied for small radial swirler with fixed curves vanes. Tests were carried out using two different sizes flame tubes of 76 mm and 140 mm inside diameter, respectively and 330 mm in length. The system was fuelled via eight vane passage fuel nozzles of 3.5 mm diameter hole. This type of fuel injection helps in mixing the fuel and air better prior to ignition. Tests were carried out at 20 mm W.G. pressure loss which is representative of gas burners for domestic central heating system operating conditions. Tests were also carried out at 400 K preheated inlet air temperature and using only natural gas as fuel. The aim of the insertion of orifice plate was to create the swirler pressure loss at the swirler outlet phase so that the swirler outlet shear layer turbulence was maximize to assist with fuel/air mixing. For the present work, the smallest orifice plate exhibited a very low NO x emissions even at 0.7 equivalence ratio were NO x is well below 10 ppm corrected at 0% oxygen at dry basis. Other emissions such as carbon monoxide and unburned hydrocarbon were below 10 ppm and 100 ppm, respectively, over a wide range of operating equivalence ratios. The implies that good combustion was achieved using the smallest orifice plate. (Author)

  17. Issues in continuous air monitoring

    International Nuclear Information System (INIS)

    Rodgers, J.C.

    1991-01-01

    The Health Physics groups at Los Alamos determined that the 15 yr-old alpha CAM instrumentation in use at the Laboratory would soon have to be replaced and upgraded. A program was initiated to prepare detailed performance specifications, evaluate new CAM instrumentation being offered, and if necessary, to develop advanced technologies which would enable the Laboratory to meet or exceed all of the requirements of the new DOE Order 5480.11. ''Radiation Protection for Occupational Workers'' (DOE, 1988), and other related Orders and standards. After careful evaluation of available alpha CAMs and consideration of the many factors affecting CAM performance, a project for the design, and development of advance CAM technology was initiated. This project culminated in the completion of a new alpha CAM concept featuring advances in the design of the CAM inlet enabling discrimination against radon daughters, in the multi-channel analyzer electronics, in the data processing and communication electronics, and in background compensation algorithm. The objective in the following discussion is examine the DOE Order 5480.11 requirements in some detail. While the new CAM sensitivity requirement is of critical importance, this is only one of many requirements of the Order with implications for CAM design, placement and operation. It is essential to orient our thinking about CAMs to the primary objectives of the Order with air monitoring implications. This paper discusses air monitoring issues in the Order. 7 refs

  18. Air Baltic: Estonian Air on nurka surutud / Teele Tammeorg

    Index Scriptorium Estoniae

    Tammeorg, Teele

    2010-01-01

    Air Balticu asepresidendi Janis Vanagsi hinnangul on Estonian Air aastaid jätnud tähelepanuta oma peamised turismiturud ning on praegu halvas seisus. Air Baltic on endiselt huvitatud Estonian Airi ostust. Majandus- ja kommunikatsiooniminister Juhan Partsi seisukoht

  19. Other primary headaches

    Directory of Open Access Journals (Sweden)

    Anish Bahra

    2012-01-01

    Full Text Available The ′Other Primary Headaches′ include eight recognised benign headache disorders. Primary stabbing headache is a generally benign disorder which often co-exists with other primary headache disorders such as migraine and cluster headache. Primary cough headache is headache precipitated by valsalva; secondary cough has been reported particularly in association with posterior fossa pathology. Primary exertional headache can occur with sudden or gradual onset during, or immediately after, exercise. Similarly headache associated with sexual activity can occur with gradual evolution or sudden onset. Secondary headache is more likely with both exertional and sexual headache of sudden onset. Sudden onset headache, with maximum intensity reached within a minute, is termed thunderclap headache. A benign form of thunderclap headache exists. However, isolated primary and secondary thunderclap headache cannot be clinically differentiated. Therefore all headache of thunderclap onset should be investigated. The primary forms of the aforementioned paroxysmal headaches appear to be Indomethacin sensitive disorders. Hypnic headache is a rare disorder which is termed ′alarm clock headache′, exclusively waking patients from sleep. The disorder can be Indomethacin responsive, but can also respond to Lithium and caffeine. New daily persistent headache is a rare and often intractable headache which starts one day and persists daily thereafter for at least 3 months. The clinical syndrome more often has migrainous features or is otherwise has a chronic tension-type headache phenotype. Management is that of the clinical syndrome. Hemicrania continua straddles the disorders of migraine and the trigeminal autonomic cephalalgias and is not dealt with in this review.

  20. Air medical transportation in India: Our experience.

    Science.gov (United States)

    Khurana, Himanshu; Mehta, Yatin; Dubey, Sunil

    2016-01-01

    Long distance air travel for medical needs is on the increase worldwide. The condition of some patients necessitates specially modified aircraft, and monitoring and interventions during transport by trained medical personnel. This article presents our experience in domestic and international interhospital air medical transportation from January 2010 to January 2014. Hospital records of all air medical transportation undertaken to the institute during the period were analyzed for demographics, primary etiology, and events during transport. 586 patients, 453 (77.3%) males and 133 (22.6%) females of ages 46.7 ± 12.6 years and 53.4 ± 9.7 years were transported by us to the institute. It took 3030 flying hours with an average of 474 ± 72 min for each mission. The most common indication for transport was cardiovascular diseases in 210 (35.8%) and central nervous system disease in 120 (20.4%) cases. The overall complication rate was 5.3% There was no transport related mortality. Cardiac and central nervous system ailments are the most common indication for air medical transportation. These patients may need attention and interventions as any critical patient in the hospital but in a difficult environment lacking space and help. Air medical transport carries no more risk than ground transportation.

  1. Determination of the air attenuation correction factor for a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia F.; Cintra, Felipe B.; Castro, Maysa C. de; Caldas, Linda V.E.

    2016-01-01

    The objective of this work is to present the experimental and simulation results for the air attenuation correction factor for a free air ionization chamber with concentric cylinders of Victoreen, model 481-5. This correction factor was obtained for the standard mammography qualities established in the Instrument Calibration Laboratory (LCI) of IPEN. The values were compared with the results from the German primary standard laboratory Physikalisch- Technische Bundesanstalt (PTB), and maximum differences of 0.40% in relation to the experimental value and 0.31% in relation to the simulated value were obtained. (author)

  2. Air-Breathing Launch Vehicle Technology Being Developed

    Science.gov (United States)

    Trefny, Charles J.

    2003-01-01

    Of the technical factors that would contribute to lowering the cost of space access, reusability has high potential. The primary objective of the GTX program is to determine whether or not air-breathing propulsion can enable reusable single-stage-to-orbit (SSTO) operations. The approach is based on maturation of a reference vehicle design with focus on the integration and flight-weight construction of its air-breathing rocket-based combined-cycle (RBCC) propulsion system.

  3. New measurements and analysis of high-energy muons in cosmic ray extensive air showers

    International Nuclear Information System (INIS)

    Sarkar, S.K.; Ghose, B.; Murkherjee, N.; Sanyal, S.; Chaudhuri, N.; Chhetri, R.; Basak, D.K.

    1991-01-01

    Cosmic ray air shower structure measurements and measurement of density and energy of air shower muons of a wide energy range simultaneously in individual air showers by two magnet spectrographs are presented. The measured muon densities have been used to compare with some of the previous measurements on muon densities in air showers of nearly the same size. The measured muon densities have also been applied for distinguishing between various interaction models and between light and heavier air shower primaries. In the air shower size range 10 4 -10 6 particles the present measurements do not provide evidence for iron primaries and the different interaction models seem not to be distinguishable by air shower observations. (Author)

  4. Air ejector augmented compressed air energy storage system

    Science.gov (United States)

    Ahrens, F.W.; Kartsounes, G.T.

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  5. Controlled air incineration

    International Nuclear Information System (INIS)

    Seitz, K.A.

    1991-01-01

    From 1960 to 1970, incineration was recognized as an economical method of solid waste disposal with many incinerators in operation through the country. During this period a number of legislation acts began to influence the solid waste disposal industry, namely, the Solid Waste Disposal Act of 1965; Resource Conservation Recovery Act (RCRA) of 1968; Resource Recovery Act of 1970; and Clean Air Act of 1970. This period of increased environmental awareness and newly created regulations began the closure of many excess air incineration facilities and encouraged the development of new controlled air, also known as Starved-Air incinerator systems which could meet the more stringent air emission standards without additional emission control equipment. The Starved-Air technology initially received little recognition because it was considered unproven and radically different from the established and accepted I.I.A. standards. However, there have been many improvements and developments in the starved-air incineration systems since the technology was first introduced and marketed, and now these systems are considered the proven technology standard

  6. Air Pollution and Stroke.

    Science.gov (United States)

    Lee, Kuan Ken; Miller, Mark R; Shah, Anoop S V

    2018-01-01

    The adverse health effects of air pollution have long been recognised; however, there is less awareness that the majority of the morbidity and mortality caused by air pollution is due to its effects on the cardiovascular system. Evidence from epidemiological studies have demonstrated a strong association between air pollution and cardiovascular diseases including stroke. Although the relative risk is small at an individual level, the ubiquitous nature of exposure to air pollution means that the absolute risk at a population level is on a par with "traditional" risk factors for cardiovascular disease. Of particular concern are findings that the strength of this association is stronger in low and middle income countries where air pollution is projected to rise as a result of rapid industrialisation. The underlying biological mechanisms through which air pollutants exert their effect on the vasculature are still an area of intense discussion. A greater understanding of the effect size and mechanisms is necessary to develop effective strategies at individual and policy levels to mitigate the adverse cardiovascular effects of air pollution.

  7. Air Quality Guide for Ozone

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Air Quality Guide for Ozone Ground-level ozone is one of our nation’s most common air pollutants. Use the chart below to help reduce ...

  8. Agriculture: Agriculture and Air Quality

    Science.gov (United States)

    Information on air emissions from agricultural practices, types of agricultural burning, air programs that may apply to agriculture, reporting requirements, and links to state and other federal air-quality information.

  9. Lean in Air Permitting Guide

    Science.gov (United States)

    The Lean in Air Permitting Guide is designed to help air program managers at public agencies better understand the potential value and results that can be achieved by applying Lean improvement methods to air permitting processes.

  10. Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as...

  11. Air Quality Management Process Cycle

    Science.gov (United States)

    Air quality management are activities a regulatory authority undertakes to protect human health and the environment from the harmful effects of air pollution. The process of managing air quality can be illustrated as a cycle of inter-related elements.

  12. Ozone - Current Air Quality Index

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Current AQI Forecast AQI Loop More Maps AQI: Good (0 - 50) ... resources for Hawaii residents and visitors more announcements Air Quality Basics Air Quality Index | Ozone | Particle Pollution | Smoke ...

  13. Regional air pollution over Malaysia

    Science.gov (United States)

    Krysztofiak, G.; Catoire, V.; Dorf, M.; Grossmann, K.; Hamer, P. D.; Marécal, V.; Reiter, A.; Schlager, H.; Eckhardt, S.; Jurkat, T.; Oram, D.; Quack, B.; Atlas, E.; Pfeilsticker, K.

    2012-12-01

    During the SHIVA (Stratospheric Ozone: Halogen Impacts in a Varying Atmosphere) campaign in Nov. and Dec. 2011 a number of polluted air masses were observed in the marine and terrestrial boundary layer (0 - 2 km) and in the free troposphere (2 - 12 km) over Borneo/Malaysia. The measurements include isoprene, CO, CO2, CH4, N2O, NO2, SO2 as primary pollutants, O3 and HCHO as secondary pollutants, and meteorological parameters. This set of trace gases can be used to fingerprint different sources of local and regional air pollution (e.g., biomass burning and fossil fuel burning, gas flaring on oil rigs, emission of ships and from urban areas, volcanic emissions, and biogenic emissions). Individual sources and location can be identified when the measurements are combined with a nested-grid regional scale chemical and meteorological model and lagrangian particle dispersion model (e.g., CCATT-BRAMS and FLEXPART). In the case of the former, emission inventories of the primary pollutants provide the basis for the trace gas simulations. In this region, the anthropogenic influence on air pollution seems to dominate over natural causes. For example, CO2 and CH4 often show strong correlations with CO, suggesting biomass burning or urban fossil fuel combustion dominates the combustion sources. The study of the CO/CO2 and CH4/CO ratios can help separate anthropogenic combustion from biomass burning pollution sources. In addition, these ratios can be used as a measure of combustion efficiency to help place the type of biomass burning particular to this region within the wider context of fire types found globally. On several occasions, CH4 enhancements are observed near the ocean surface, which are not directly correlated with CO enhancements thus indicating a non-combustion-related CH4 source. Positive correlations between SO2 and CO show the anthropogenic influence of oil rigs located in the South China Sea. Furthermore, SO2 enhancements are observed without any increase in CO

  14. Primary Ectopic Ethmoidal Craniopharyngioma.

    Science.gov (United States)

    Preti, Andrea; Karligkiotis, Apostolos; Facco, Carla; Ottini, Giorgia; Volpi, Luca; Castelnuovo, Paolo

    2017-06-01

    Craniopharyngiomas are benign but aggressive epithelial tumors usually originating in the anterior lobe of the pituitary gland from squamous remnants of an incompletely involuted craniopharingeal duct developing from the Rathke pouch. To the authors' knowledge only 1 patient of a primary isolated ethmoidal craniopharyngioma has been reported in the literature.The authors report the case of a 17-year-old boy with a primary extracranial ethmoidal craniopharyngioma. An endoscopic endonasal approach was employed to resect the tumor. After 2 years of clinical and radiological follow-up no recurrence of disease was observed.Primary ethmoidal craniopharyngiomas are rare entities and biopsy is necessary for diagnosis. However, a preoperative assessment by means of nasal endoscopy, computed tomography scan, and enhanced magnetic resonance imaging is mandatory to better evaluate the extension and characteristics of the tumor. The endoscopic endonasal technique is a safe and effective approach for the treatment of these lesions.

  15. Primary renal synovial sarcoma

    Directory of Open Access Journals (Sweden)

    Girish D. Bakhshi

    2012-03-01

    Full Text Available Primary Renal Sarcoma is rare tumor comprising only 1% of all renal tumours. Synovial sarcomas are generally deep-seated tumors arising in the proximity of large joints of adolescents and young adults and account for 5-10% of all soft tissue tumours. Primary synovial sarcoma of kidney is rare and has poor prognosis. It can only be diagnosed by immunohistochemistry. It should be considered as a differential in sarcomatoid and spindle cell tumours. We present a case of 33-year-old female, who underwent left sided radical nephrectomy for renal tumour. Histopathology and genetic analysis diagnosed it to be primary renal synovial sarcoma. Patient underwent radiation therapy and 2 years follow up is uneventful. A brief case report with review of literature is presented.

  16. Primary headaches in children

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Pan

    2015-01-01

    Full Text Available Headache is a widespread clinical problem; the prevalence is high in all age groups, from which children and teenagers are not spared. It has been reported that, as many as 75% of school-age children may experience headache infrequently, among them 10% have recurrent headaches. [1],[2] The vast majority of headaches are primary and classified as migraine, tension-type headache (TTH, cluster headache, and other trigeminal autonomic cephalgias. The type of primary headaches could usually be diagnosed by a thorough and careful history taking, and physical examination. Once the diagnosis of migraine is established and appropriate reassurance provided, a balanced and individually tailored treatment plan can be instituted. The goal of treatment includes abortive or acute pain treatment, preventive long-term treatment, and biobehavioral therapy. Knowledge of precise impact of primary headaches on child′s quality of life helps to design a proper comprehensive treatment plan.

  17. Normocalcemic primary hyperparathyroidism

    Science.gov (United States)

    Bilezikian, John P.; Silverberg, Shonni J.

    2011-01-01

    SUMMARY Primary hyperparathyroidism is a common disorder of mineral metabolism characterized by incompletely regulated, excessive secretion of parathyroid hormone from one or more of the parathyroid glands. The historical view of this disease describes two distinct entities marked by two eras. When primary hyperparathyroidism was first discovered about 80 years ago, it was always symptomatic with kidney stones, bone disease and marked hypercalcemia. With the advent of the multichannel autoanalyzer about 40 years ago, the clinical phenotype changed to a disorder characterized by mild hypercalcemia and the absence of classical other features of the disease. We may now be entering a 3rd era in the history of this disease in which patients are being discovered with normal total and ionized serum calcium concentrations but with parathyroid hormone levels that are consistently elevated. In this article, we describe this new entity, normocalcemic primary hyperparathyroidism, a forme fruste of the disease. PMID:20485897

  18. The Controversy Behind the Air Corps Tactical School's Strategic Bombardment Theory: An Analysis of the Bombardment Versus Pursuit Aviation Data Between 1930-1939

    National Research Council Canada - National Science Library

    Severs, Hugh

    1997-01-01

    ... at the expense of pursuit aviation. The report used primary source data from the Air Force Historical Research Agency and various secondary sources to analyze results of Air Corps training exercises and combat data from overseas conflicts...

  19. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  20. Air/Water Purification

    Science.gov (United States)

    1992-01-01

    After 18 years of research into air/water pollution at Stennis Space Center, Dr. B. C. Wolverton formed his own company, Wolverton Environmental Services, Inc., to provide technology and consultation in air and water treatment. Common houseplants are used to absorb potentially harmful materials from bathrooms and kitchens. The plants are fertilized, air is purified, and wastewater is converted to clean water. More than 100 U.S. communities have adopted Wolverton's earlier water hyacinth and artificial marsh applications. Catfish farmers are currently evaluating the artificial marsh technology as a purification system.

  1. Appendicitis with Intraluminal Air

    International Nuclear Information System (INIS)

    Fernandez, Alfredo; Ramirez, Sandra M; Rodriguez, Cesar A; Uriza, Luis F

    2010-01-01

    The presentation of acute appendicitis with intraluminal air is an uncommon presentation. Ultrasound is a widely used and accepted to establish the diagnosis of appendicitis, but its performance is limited in situations where there is interposition of air. Inflamed appendix which presents with distension by gas can be source of error in ultrasound to establish a false negative diagnosis. In this article we present three patients with appendicitis where the interposition of intraluminal air hid their diagnostic by ultrasound. In all three cases the definitive diagnosis was established by computed tomography and surgical confirmation.

  2. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  3. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  4. Olefin metathesis in air

    Directory of Open Access Journals (Sweden)

    Lorenzo Piola

    2015-10-01

    Full Text Available Since the discovery and now widespread use of olefin metathesis, the evolution of metathesis catalysts towards air stability has become an area of significant interest. In this fascinating area of study, beginning with early systems making use of high oxidation state early transition metal centers that required strict exclusion of water and air, advances have been made to render catalysts more stable and yet more functional group tolerant. This review summarizes the major developments concerning catalytic systems directed towards water and air tolerance.

  5. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  6. Air tight electrical box

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, C.G.

    1990-08-14

    An air-impervious electrical box to facilitate air sealing a house comprises an integral, rigid box body having a continuous flange, integral with the body, circumscribing and outwardly extending from the sides of the body. This flange is rearwardly positioned behind the front edges of the sides of the body a predetermined distance so that the electrical box may be secured to framing by nailing through the flange. Drywall is then secured to the frame on top of and adjecent to the flange. Such box eliminates the necessity for solid backing and minimizes passage of air through the box and space between the drywall and the box.

  7. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  8. [Primary care in Ireland].

    Science.gov (United States)

    Sánchez-Sagrado, T

    Spanish doctors are still leaving the country to look for quality work. Ireland is not a country with many Spanish professionals but it is interesting to know its particular Health care system. Ireland is one of the countries with a national health care system, although it has a mixture of private health care insurance schemes. People have a right to health care if they have been living in Ireland at least for a year. Access to the primary care health system depends on age and income: free of charge for Category 1 and co-payments for the rest. This division generates great inequalities among the population. Primary Care doctors are self-employed, and they work independently. However, since 2001 they have tended to work in multidisciplinary teams in order to strengthen the Primary Care practice. Salary is gained from a combination of public and private incomes which are not differentiated. The role of the General Practitioner consists in the treatment of acute and chronic diseases, minor surgery, child care, etc. There is no coordination between Primary and Secondary care. Access to specialised medicine is regulated by the price of consultation. Primary Care doctors are not gatekeepers. To be able to work here, doctors must have three years of training after medical school. After that, Continuing Medical Education is compulsory, and the college of general practitioners monitors it annually. The Irish health care system does not fit into the European model. Lack of a clear separation between public and private health care generates great inequalities. The non-existence of coordination between primary and specialised care leads to inefficiencies, which Ireland cannot allow itself after a decade of economic crisis. Copyright © 2017 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Thoughts on primary care.

    Science.gov (United States)

    Raskin, Lynne

    2010-01-01

    The uptake of family health teams in Ontario has been tremendous. And the creation of group practices in primary care has taken root in other provinces as well. For many people, being involved with something new is exciting. At the same time, once they are committed, they discover the challenges that can be simultaneously exhilarating and frustrating. This issue of Healthcare Quarterly offers two articles that provide interesting reflections on what has been learned so far from the perspectives of both team leadership and the team members themselves within a transforming primary care system.

  10. Primary lymphoma of the brain

    Science.gov (United States)

    Brain lymphoma; Cerebral lymphoma; Primary lymphoma of the central nervous system; Lymphoma - brain ... The cause of primary brain lymphoma is not known. People with a weakened immune system are at high risk for primary lymphoma of the brain. ...

  11. Air-Inflated Fabric Structures

    National Research Council Canada - National Science Library

    Cavallaro, Paul V; Sadegh, Ali M

    2006-01-01

    .... Examples include air ships, weather balloons, inflatable antennas and radomes, temporary shelters, pneumatic muscles and actuators, inflatable boats, temporary bridging, and energy absorbers such as automotive air bags...

  12. Radionuclides and trace metals in surface air. Appendix C

    International Nuclear Information System (INIS)

    Feely, H.W.; Toonkel, L.E.; Larsen, R.J.

    1981-01-01

    Since January 1963, the Environmental Measurements Laboratory (EML), formerly the Health and Safety Laboratory (HASL), has been conducting the Surface Air Sampling Program. This study is a direct outgrowth of a program initiated by the US Naval Research Laboratory (NRL) in 1957 and continued through 1962. The primary objective of this program is to study the spatial and temporal distribution of specific natural and man-made radioisotopes, and of trace metals in the surface air. Other special studies of surface air contamination have been performed during the course of the program

  13. Discussion in primary ecological environmental problems and relevant countermeasures in China

    International Nuclear Information System (INIS)

    An Yongfeng

    2003-01-01

    On the basis of sufficient statistical data, the primary ecological environmental problems, including water/soil loss and dissertation, water resource shortage and water pollution, deterioration of air quality and air pollution, despoilation of biodiversity, and environmental pollution, are listed in this paper. In addition, the causes of these problems are analyzed. Finally, relevant strategies and measures for environmental protection are brought forward. (authors)

  14. Integrated Technology Air Cleaners (ITAC): Design and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

    2013-09-13

    The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

  15. Regional Air Quality Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset provides data on regional air quality, including trace level SO2, nitric acid, ozone, carbon monoxide, and NOy; and particulate sulfate, nitrate, and...

  16. Healthy Air Outdoors

    Science.gov (United States)

    ... a few sources. Even natural sources such as fires and dust contribute to air pollution. Learn more ... Walks Cycling Events Donate a Car Memorial & Honor Gifts Planned Giving Christmas Seals ABOUT THE LUNG ASSOCIATION ...

  17. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  18. Air Travel Health Tips

    Science.gov (United States)

    ... if you touch anything in your seat back pocket. The air pressure in the plane can change ... counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom Checker BMI Calculator myhealthfinder Immunization Schedules Nutrient ...

  19. Hanscom Air Force Base

    Data.gov (United States)

    Federal Laboratory Consortium — MIT Lincoln Laboratory occupies 75 acres (20 acres of which are MIT property) on the eastern perimeter of Hanscom Air Force Base, which is at the nexus of Lexington,...

  20. Improving Indoor Air Quality

    Science.gov (United States)

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  1. State Air Quality Standards.

    Science.gov (United States)

    Pollution Engineering, 1978

    1978-01-01

    This article presents in tabular form the air quality standards for sulfur dioxide, carbon monoxide, nitrogen dioxide, photochemicals, non-methane hydrocarbons and particulates for each of the 50 states and the District of Columbia. (CS)

  2. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  3. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  4. Advanced air distribution

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2011-01-01

    The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...

  5. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  6. Calidad del aire interior

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues including health risks and means by which human exposures can be reduced. Content on this site will be focused on Spanish translated resources for information about indoor air quality.

  7. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  8. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  9. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  10. Process air quality data

    Science.gov (United States)

    Butler, C. M.; Hogge, J. E.

    1978-01-01

    Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

  11. Air void clustering.

    Science.gov (United States)

    2015-06-01

    Air void clustering around coarse aggregate in concrete has been identified as a potential source of : low strengths in concrete mixes by several Departments of Transportation around the country. Research was : carried out to (1) develop a quantitati...

  12. Surgery of Primary Melanomas

    Directory of Open Access Journals (Sweden)

    Piotr Rutkowski

    2010-05-01

    Full Text Available Surgery remains the mainstay of melanoma therapy, regardless of the tumor site. Only the early diagnosis combined with proper surgical therapy currently gives patients affected by this malignancy the chance for a full cure. The main goal of surgical therapy is to provide the local control of the disease and to secure long-term survival of the patient without reasonable functional and esthetic impairment. The recommended method of biopsy—excisional biopsy, as an initial diagnostic and, to some extent, therapeutic procedure—is performed under local anesthesia as an elliptical incision with visual clear margins of 1–3 mm and with some mm of subcutaneous tissue. The extent of radical excision of the primary tumor (or scar after excisional biopsy is based on the histopathologic characteristics of the primary tumor and usually consists of 1–2 cm margins with primary closure. The philosophy behind conducted randomized clinical trials has been to find the most conservative surgical approach that is able to guarantee the same results as more demolitive treatment. This has been the background of the trials designed to define the correct margins of excision around a primary cutaneous melanoma. Much less definition can be dedicated to the surgical management of patients with non-cutaneous melanomas.

  13. Surgery of Primary Melanomas

    Energy Technology Data Exchange (ETDEWEB)

    Rutkowski, Piotr, E-mail: rutkowskip@coi.waw.pl; Zdzienicki, Marcin; Nowecki, Zbigniew I. [Soft Tissue/Bone Sarcoma and Melanoma Department, M. Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Akkooi, Alexander C. J. van [Erasmus University Medical Center-Daniel den Hoed Cancer Center, Rotterdam (Netherlands)

    2010-05-11

    Surgery remains the mainstay of melanoma therapy, regardless of the tumor site. Only the early diagnosis combined with proper surgical therapy currently gives patients affected by this malignancy the chance for a full cure. The main goal of surgical therapy is to provide the local control of the disease and to secure long-term survival of the patient without reasonable functional and esthetic impairment. The recommended method of biopsy—excisional biopsy, as an initial diagnostic and, to some extent, therapeutic procedure—is performed under local anesthesia as an elliptical incision with visual clear margins of 1–3 mm and with some mm of subcutaneous tissue. The extent of radical excision of the primary tumor (or scar after excisional biopsy) is based on the histopathologic characteristics of the primary tumor and usually consists of 1–2 cm margins with primary closure. The philosophy behind conducted randomized clinical trials has been to find the most conservative surgical approach that is able to guarantee the same results as more demolitive treatment. This has been the background of the trials designed to define the correct margins of excision around a primary cutaneous melanoma. Much less definition can be dedicated to the surgical management of patients with non-cutaneous melanomas.

  14. Surgery of Primary Melanomas

    International Nuclear Information System (INIS)

    Rutkowski, Piotr; Zdzienicki, Marcin; Nowecki, Zbigniew I.; Akkooi, Alexander C. J. van

    2010-01-01

    Surgery remains the mainstay of melanoma therapy, regardless of the tumor site. Only the early diagnosis combined with proper surgical therapy currently gives patients affected by this malignancy the chance for a full cure. The main goal of surgical therapy is to provide the local control of the disease and to secure long-term survival of the patient without reasonable functional and esthetic impairment. The recommended method of biopsy—excisional biopsy, as an initial diagnostic and, to some extent, therapeutic procedure—is performed under local anesthesia as an elliptical incision with visual clear margins of 1–3 mm and with some mm of subcutaneous tissue. The extent of radical excision of the primary tumor (or scar after excisional biopsy) is based on the histopathologic characteristics of the primary tumor and usually consists of 1–2 cm margins with primary closure. The philosophy behind conducted randomized clinical trials has been to find the most conservative surgical approach that is able to guarantee the same results as more demolitive treatment. This has been the background of the trials designed to define the correct margins of excision around a primary cutaneous melanoma. Much less definition can be dedicated to the surgical management of patients with non-cutaneous melanomas

  15. Primary intestinal lymphangiectasia.

    Science.gov (United States)

    Suresh, N; Ganesh, R; Sankar, Janani; Sathiyasekaran, Malathi

    2009-10-01

    Primary intestinal lymphangiectasia (PIL) is a rare disease of intestinal lymphatics presenting with hypoproteinemia, bilateral lower limb edema, ascites, and protein losing enteropathy. We report a series of 4 children from Chennai, India presenting with anasarca, recurrent diarrhea, hypoproteinemia and confirmatory features of PIL on endoscopy and histopathology.

  16. Healthcare is primary

    Directory of Open Access Journals (Sweden)

    Raman Kumar

    2015-01-01

    Full Text Available India is undergoing a rapid transformation in terms of governance, administrative reforms, newer policy develoment, and social movements. India is also considered one of the most vibrant economies in the world. The current discourse in public space is dominated by issues such as economic development, security, corruption free governance, gender equity, and women safety. Healthcare though remains a pressing need of population; seems to have taken a backseat. In the era of decreasing subsidies and cautious investment in social sectors, the 2 nd National Conference on Family Medicine and Primary Care 2015 (FMPC brought a focus on "healthcare" in India. The theme of this conference was "Healthcare is Primary." The conference participants discussed on the theme of why healthcare should be a national priority and why strong primary care should remain at the center of healthcare delivery system. The experts recommended that India needs to strengthen the "general health system" instead of focusing on disease based vertical programs. Public health system should have capacity and skill pool to be able to deliver person centered comprehensive health services to the community. Proactive implementation of policies towards human resource in health is the need of the hour. As the draft National Health Policy 2015 is being debated, "family medicine" (academic primary care, the unfinished agenda of National Health Policy 2002, remains a priority area of implementation.

  17. Multiple Primary Tumors

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... breast and ascending colon. KEYWORDS: Carcinoid, colorectal cancer, metachronous, synchronous. Multiple Primary Tumors. MA Adeyanju, AA Ilori. Address for correspondence: Dr. MA Adeyanju,. Department of Surgery, Federal Medical Centre, Ebute Metta,. Lagos, Nigeria. E-mail: mbadeyanju@yahoo.

  18. Primary malignant intramedullary lymphoma

    International Nuclear Information System (INIS)

    Orrego P, E.; Heinicke Y, H.; Arbaiza A, D.; Yepez R, V.

    1999-01-01

    A case of primary malignant intramedullary lymphoma, localized in the dorsal part of the spinal cord is presented. The clinical symptoms were associated with motor and sensitive deficit. Clinical investigations excluded the presence of lymphoma in other locations in the central nervous system and the extra neural organs. Postoperative radiotherapy and chemotherapy improved relict neurological symptoms. (authors)

  19. Primary black holes

    International Nuclear Information System (INIS)

    Novikov, I.; Polnarev, A.

    1981-01-01

    Proves are searched for of the formation of the so-called primary black holes at the very origin of the universe. The black holes would weigh less than 10 13 kg. The formation of a primary black hole is conditional on strong fluctuations of the gravitational field corresponding roughly to a half of the fluctuation maximally permissible by the general relativity theory. Only big fluctuations of the gravitational field can overcome the forces of the hot gas pressure and compress the originally expanding matter into a black hole. Low-mass black holes have a temperature exceeding that of the black holes formed from stars. A quantum process of particle formation, the so-called evaporation takes place in the strong gravitational field of a black hole. The lower the mass of the black hole, the shorter the evaporation time. The analyses of processes taking place during the evaporation of low-mass primary black holes show that only a very small proportion of the total mass of the matter in the universe could turn into primary black holes. (M.D.)

  20. Familial primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Iqbal, P.; Javed, R.

    2007-01-01

    A case of primary hyperparathyroidism in a 17 years old female is described. Patient presented with severe abdominal and pelvic pains associate with discomfort. Diagnostic testing revealed multiple upper and lower limb fractures and renal stones. Case was self limiting. Patient's condition resolved on parathyroidectomy for adenoma and partial thyroidectomy. Follow-up showed familial links. (author)

  1. Multiple Primary Cancer Monograph

    Science.gov (United States)

    To identify groups of cancer survivors that are at increased risk for multiple primary cancers, investigators led an effort to provide the first comprehensive population-based analysis of the risk of subsequent cancer in the U.S., resulting in a monograph.

  2. Primary cosmic ray flux

    Energy Technology Data Exchange (ETDEWEB)

    Stanev, Todor

    2001-05-01

    We discuss the primary cosmic ray flux from the point of view of particle interactions and production of atmospheric neutrinos. The overall normalization of the cosmic ray flux and its time variations and site dependence are major ingredients of the atmospheric neutrino predictions and the basis for the derivation of the neutrino oscillation parameters.

  3. in primary care

    African Journals Online (AJOL)

    Claire van Deventer

    Keywords: child HIV, doctor involvement, primary health care, quality improvement ... expertise increased, PHC facilities are now expected to be able to .... organised patient documentation were revisited. .... Review: what can we learn from quality ... South Pacific: Review of evidence and lessons from an innovative.

  4. [Primary and secondary encopresis].

    Science.gov (United States)

    Lang-Langer, Ellen

    2007-01-01

    While the difficulty of the child to part with its faeces in primary encopresis is linked to the incapability to experience the object as separated and independent from himself, secondary encopresis is a progressed psychical state of development. In this case we have to deal with regression caused by conflict. Two case-studies show clearly the differences.

  5. Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The research on air distribution in rooms is often done as full-size investigations, scale-model investigations or by Computational Fluid Dynamics (CFD). New activities have taken place within all three areas and this paper draws comparisons between the different methods. The outcome of the l......EA sponsored research "Air Flow Pattern within Buildings" is used for comparisons in some parts of the paper because various types of experiments and many countries are involved....

  6. Indoor Air Pollution

    OpenAIRE

    Kirk R. Smith

    2003-01-01

    Outdoor air pollution in developing-country cities is difficult to overlook. Indoor air pollution caused by burning such traditional fuels as wood, crop residues, and dung is less evident, yet it is responsible for a significant part of country and global disease burdens. The main groups affected are poor women and children in rural areas and urban slums as they go about their daily activi...

  7. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  8. Canada's Clean Air Act

    International Nuclear Information System (INIS)

    2006-01-01

    This paper provided an outline of Canada's Clean Air Act and examined some of the regulatory changes that will occur as a result of its implementation. The Act is being introduced to strengthen the legislative basis for taking action on reducing air pollution and GHGs, and will allow the government to regulate both indoor and outdoor air pollutants and GHGs. The Act will require the Ministers of the Environment and Health to establish national air quality objectives, as well as to monitor and report on their attainment. The Canadian Environmental Protection Act will be amended to enable the government to regulate the blending of fuels and their components. The Motor Vehicle Fuel Consumption Standards Act will also be amended to enhance the government's authority to regulate vehicle fuel efficiency. The Energy Efficiency Act will also be expanded to allow the government to set energy efficiency standards and labelling requirements for a wider range of consumer and commercial products. The Act will commit to short, medium and long-term industrial air pollution targets. Regulations will be proposed for emissions from industry; on-road and off-road vehicles and engines; and consumer and commercial products. It was concluded that the Government of Canada will continue to consult with provinces, territories, industries and Canadians to set and reach targets for the reduction of both indoor and outdoor air pollutants and GHG emissions. 6 figs

  9. The urban air; L'air de la ville

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This paper presents the abstracts of conferences proposed during the meeting on the urban air, organized by the French Meteorological Society in november 2002. These conferences dealt with the air quality monitoring, the public health impacts, the air pollution in function of the meteorological effects, the pollutants, the main factors of the air quality and the models of the meteorology. (A.L.B.)

  10. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  11. Infants Can Study Air Science.

    Science.gov (United States)

    Ward, Alan

    1983-01-01

    Provided are activities and demonstrations which can be used to teach infants about the nature of air, uses of air, and objects that fly in the air. The latter include airships, hot-air balloons, kites, parachutes, airplanes, and Hovercraft. (JN)

  12. Spirometry in primary care

    Science.gov (United States)

    Coates, Allan L; Graham, Brian L; McFadden, Robin G; McParland, Colm; Moosa, Dilshad; Provencher, Steeve; Road, Jeremy

    2013-01-01

    Canadian Thoracic Society (CTS) clinical guidelines for asthma and chronic obstructive pulmonary disease (COPD) specify that spirometry should be used to diagnose these diseases. Given the burden of asthma and COPD, most people with these diseases will be diagnosed in the primary care setting. The present CTS position statement was developed to provide guidance on key factors affecting the quality of spirometry testing in the primary care setting. The present statement may also be used to inform and guide the accreditation process for spirometry in each province. Although many of the principles discussed are equally applicable to pulmonary function laboratories and interpretation of tests by respirologists, they are held to a higher standard and are outside the scope of the present statement. PMID:23457669

  13. Cancer of unknown primary

    DEFF Research Database (Denmark)

    Dyrvig, Anne-Kirstine; Yderstræde, Knud Bonnet; Gerke, Oke

    2017-01-01

    210 (38.7%) had a CUP diagnosis confirmed. Within the cohort, 347 patients (64.0%) had a registration in CR matching with the NPR registration. Exposure to diagnostic procedures included biopsy (n = 439, 81.0%) and image modalities (n = 532, 98.2%). Survival was poor with 67 (12.4%) individuals alive...... after 4 years.The validity of a CUP diagnosis in NPR was low when using data from CR as reference. More than half the suspected CUP patients had a previous cancer diagnosis with CUP being the most frequent. Patients were diagnosed in compliance with guidelines indicating high external validity, but less...... than 1 quarter had their primary identified and the 1-year survival was approximately 20%. Research is needed to develop efficacious methods for primary detection....

  14. Primary omental pregnancy

    International Nuclear Information System (INIS)

    Yildizhan, R.; Kurdoglu, M.; Kolusari, A.; Erten, R.

    2008-01-01

    Omental pregnancy is a rare form of ectopic pregnancy and can be seen primarily or secondary to a tubal pregnancy. A 25-yeal-old woman presented with abdominal distention with pain and anemia without vaginal bleeding. After a provisional diagnosis of ruptured ectopic pregnancy, laparotomy was performed. On surgical exploration, the bilateral tubes and ovaries were intact, however, an omental pregnancy was detected as the cause of hemoperitoneum. Partial omentectomy was performed. Although most cases are secondary, presented here is an additional case of primary omental pregnancy at 12 weeks according to Studdiford's criteria. Histological evidence of neovascularization into the supporting tissue confirmed our diagnosis. A primary omental pregnancy should always be considered as a possible explanation for severe hemoperitoneum in ectopic pregnancies presenting with acute abdomen and with intact adnexes on surgical exploration. (author)

  15. Basics of primary immunodeficiencies

    Directory of Open Access Journals (Sweden)

    Claudia Hernández-Martínez

    2016-05-01

    Full Text Available Primary immunodeficiencies (PID are a heterogeneous group of inherited disorders, the etiology are the defects in the development or function of the immune system. The principal PID manifestations are the infections in early age, malignancy and diseases of immune dysregulation as autoimmunity and allergy. PIDs are genetics disorders and most of them are inherited as autosomal recessive, also this group of diseases is more prevalent in males and in childhood. The antibody immunodeficiency is the PID more common in adults. The more frequent disorders are the infections in the respiratory tract, abscesses, candidiasis, diarrhea, BCGosis etc. Initial approach included a complete blood count and quantification of immunoglobulins. The delay in diagnosis could be explained due to a perception that the recurrent infections are normal process or think that they are exclusively of childhood. The early diagnosis of PID by primary care physicians is important to opportune treatment and better prognosis.

  16. [Primary care in France].

    Science.gov (United States)

    Sánchez-Sagrado, T

    2016-01-01

    The poor planning of health care professionals in Spain has led to an exodus of doctors leaving the country. France is one of the chosen countries for Spanish doctors to develop their professional career. The French health care system belongs to the Bismarck model. In this model, health care system is financed jointly by workers and employers through payroll deduction. The right to health care is linked to the job, and provision of services is done by sickness-funds controlled by the Government. Primary care in France is quite different from Spanish primary care. General practitioners are independent workers who have the right to set up a practice anywhere in France. This lack of regulation has generated a great problem of "medical desertification" with problems of health care access and inequalities in health. French doctors do not want to work in rural areas or outside cities because "they are not value for money". Medical salary is linked to professional activity. The role of doctors is to give punctual care. Team work team does not exist, and coordination between primary and secondary care is lacking. Access to diagnostic tests, hospitals and specialists is unlimited. Duplicity of services, adverse events and inefficiencies are the norm. Patients can freely choose their doctor, and they have a co-payment for visits and hospital care settings. Two years training is required to become a general practitioner. After that, continuing medical education is compulsory, but it is not regulated. Although the French medical Health System was named by the WHO in 2000 as the best health care system in the world, is it not that good. While primary care in Spain has room for improvement, there is a long way for France to be like Spain. Copyright © 2015 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  17. [Primary care in Italy].

    Science.gov (United States)

    Sánchez-Sagrado, T

    Italy is not a country where Spanish doctors emigrate, as there is an over-supply of health care professionals. The Italian Servizio Sanitario Nazionale has some differences compared to the Spanish National Health System. The Servizio Sanitario Nazionale is financed by national and regional taxes and co-payments. There are taxes earmarked for health, and Primary Care receives 50% of the total funds. Italian citizens and residents in Italy have the right to free health cover. However, there are co-payments for laboratory and imaging tests, pharmaceuticals, specialist ambulatory services, and emergencies. Co-payments vary in the different regions. The provision of services is regional, and thus fragmentation and major inequities are the norm. Doctors in Primary Care are self-employed and from 2000 onwards, there are incentives to work in multidisciplinary teams. Salary is regulated by a national contract and it is the sum of per-capita payments and extra resources for specific activities. Responsibilities are similar to those of Spanish professionals. However, medical care is more personal. Relationships between Primary Care and specialised care depend on the doctors' relationships. Primary Care doctors are gatekeepers for specialised care, except for gynaecology, obstetrics and paediatrics. Specialised training is compulsory in order to work as general practitioner. The Italian Health Care System is a national health system like the Spanish one. However, health care professionals are self-employed, and there are co-payments. In spite of co-payments, Italians have one of the highest average life expectancy, and they support a universal and publicly funded health-care system. Copyright © 2017 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Primary Tunnel Junction Thermometry

    International Nuclear Information System (INIS)

    Pekola, Jukka P.; Holmqvist, Tommy; Meschke, Matthias

    2008-01-01

    We describe the concept and experimental demonstration of primary thermometry based on a four-probe measurement of a single tunnel junction embedded within four arrays of junctions. We show that in this configuration random sample specific and environment-related errors can be avoided. This method relates temperature directly to Boltzmann constant, which will form the basis of the definition of temperature and realization of official temperature scales in the future

  19. Primary stabbing headache.

    Science.gov (United States)

    Pareja, Juan A; Sjaastad, Ottar

    2010-01-01

    Primary stabbing headache is characterized by transient, cephalic ultrashort stabs of pain. It is a frequent complaint with a prevalence of 35.2%, a female preponderance, and a mean age of onset of 28 years (Vågå study). Attacks are generally characterized by moderate to severe, jabbing or stabbing pain, lasting from a fraction of a second to 3s. Attack frequency is generally low, with one or a few attacks per day. The paroxysms generally occur spontaneously, during daytime. Most patients exhibit a sporadic pattern, with an erratic, unpredictable alternation between symptomatic and non-symptomatic periods. Paroxysms are almost invariably unilateral. Temporal and fronto-ocular areas are most frequently affected. Attacks tend to move from one area to another, in either the same or the opposite hemicranium. Jabs may be accompanied by a shock-like feeling and even by head movement - "jolts" -or vocalization. On rare occasions, conjunctival hemorrhage and monocular vision loss have been described as associated features. Primary stabbing headache may concur, synchronously or independently, with other primary headaches. In contrast to what is the case in adults, in childhood it is not usually associated with other headaches. Treatment is rarely necessary. Indomethacin, 75-150 mg daily, may seem to be of some avail. Celecoxib, nifedipine, melatonin, and gabapentin have been reported to be effective in isolated cases and small series of patients. The drug studies need corroboration. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Determination of the saturation curve of a primary standard for low energy X-ray beams

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Poledna, Roberto; Peixoto, Jose Guilherme P.

    2003-01-01

    Thr free air is the well recognized as the primary standard for the measurement of kerma in the air due to his characteristics to perform the absolute measurements of that entity according to definitions. Therefore, the Institute for Radioprotection and dosimetry - IRD, Brazil used for his implantation a free air cylindrical ionization chamber. Initially, a mechanical characterization was performed for verification as a primary standard. This paper will proceed a full detailed description the point operation of 2000 V found for that chamber and her saturation coefficient

  1. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  2. Advanced air detritiation dryer

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The isotopic exchange principle has proved effective in increasing air detritiation factors of atmospheric dryers. A CFFTP/AECL Chalk River program has demonstrated detritiation factors of 100,000 in trials. The technology is designed for application on regenerating atmospheric dryers using molecular sieve desiccant beds, used in rooms likely to encounter airborne tritium contamination. Dryer design concepts for dryers at JET (Joint European Torus, England) and ITER have been prepared by Alan Dombra of AECL, using the isotopic exchange technology. The isotopic exchange method works by passing tritiated air over a detritiated desiccant bed. Airborne tritium atoms are exchanged in the bed for ordinary hydrogen atoms from the bed's residual moisture loading. Tritium remains on the bed until it is discharged in a regeneration cycle. During regeneration, the desiccant bed is first heated with hot, dry air to drive off collected tritiated moisture. Airborne tritium removed from the air is collected as a tritiated water distillate and stored for later processing. During the second part of the regeneration cycle, the desiccant bed is washed with clean moist air to elute remaining traces of tritium and to refresh the bed to ready it for another tritium absorption period

  3. AIR GAP CONTROL SYSTEM FOR HYDROGENERATORS

    Directory of Open Access Journals (Sweden)

    I. O. Zaitsev

    2017-01-01

    Full Text Available In this paper, we report of the solving the actual problem of control the air gap in the hydrogenerators. The aim of the study was development of a computerized information-measuring system for measuring the air gap in the hydrogenator, which used two capacitive sensors with parallel coplanar electrodes, and the method of determining the shape of the envelope parameters hydrogenerator rotor poles relative to the center axis of rotation, using the measurement results of the air gap.In practical studies of the sensor circuit it has been shown that its use allows for the informative value of the sensor capacitance conversion function to obtain a high accuracy and resolution measurement with digital linearization of converting function of the sensor with use program utility. To determine the form deviations of the envelope line of the rotor pole from the ideal cylinder, which is one of the main structural defects of the technological errors as results the distortion of the shape of the air gap in the hydrogenator, when the machine was manufacture and assembly. It is proposed to describe the shape of the envelope to use a Fourier transform. Calculation of the coefficients of the Fourier series is performed using the method of least squares as the regression coefficients.Application of this method in processing the measuring data in a computerized information-measuring system the developed with the primary converter with coplanar parallel electrodes allowed attaining the high measurement accuracy and resolution informative in magnitude of the capacity.

  4. [Primary headache and depression].

    Science.gov (United States)

    Gesztelyi, Gyöngyi

    2004-11-28

    Primary headaches--mainly tension-type headache and migraine--affect a significant portion of the population. Depression is also highly prevalent. The co-existence of a primary headache and depression in the same patient therefore might be a coincidence due to the high prevalence of these conditions, but there might be a causal relationship between them, or headaches and depression might have a common background. This review of the literature summarizes the features of the relationship between primary headaches and depression. Depression is more prevalent in headache patients than in the headache-free population. Prospective epidemiological studies suggest a common genetic, biochemical or environmental background behind primary headaches and depression. This theory is supported by the role of the same neurotransmitter systems (mostly serotonin and dopamine) in headaches as well as in depression. Comorbid depression is associated with female gender, higher age, and higher frequency of headaches. Most depression inventories--questionnaires used to screen for the severity of depressive symptoms--contain transdiagnostic items, therefore their use in their original form is limited in organic diseases: due to the somatic items they might overestimate the severity of depression. When examining a headache patient special attention should be paid to the recognition of comorbid depression. The diagnosis of suspected mood disorder could be supported by using simple screening methods, such as the original or the abbreviated versions of standard depression inventories, but the final diagnosis of major depression needs psychiatric evaluation. Quality of life of the headache patient is affected not only by the characteristics of pain (frequency, duration, severity) but also by the disability caused by headache and the associating mood disorder. Recognizing coexisting mood disorder and disability helps to make the best treatment choice for the acute and preventive treatment of

  5. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  6. What can individuals do to reduce personal health risks from air pollution?

    Science.gov (United States)

    Laumbach, Robert; Meng, Qingyu; Kipen, Howard

    2015-01-01

    In many areas of the world, concentrations of ambient air pollutants exceed levels associated with increased risk of acute and chronic health problems. While effective policies to reduce emissions at their sources are clearly preferable, some evidence supports the effectiveness of individual actions to reduce exposure and health risks. Personal exposure to ambient air pollution can be reduced on high air pollution days by staying indoors, reducing outdoor air infiltration to indoors, cleaning indoor air with air filters, and limiting physical exertion, especially outdoors and near air pollution sources. Limited evidence suggests that the use of respirators may be effective in some circumstances. Awareness of air pollution levels is facilitated by a growing number of public air quality alert systems. Avoiding exposure to air pollutants is especially important for susceptible individuals with chronic cardiovascular or pulmonary disease, children, and the elderly. Research on mechanisms underlying the adverse health effects of air pollution have suggested potential pharmaceutical or chemopreventive interventions, such as antioxidant or antithrombotic agents, but in the absence of data on health outcomes, no sound recommendations can be made for primary prevention. Health care providers and their patients should carefully consider individual circumstances related to outdoor and indoor air pollutant exposure levels and susceptibility to those air pollutants when deciding on a course of action to reduce personal exposure and health risks from ambient air pollutants. Careful consideration is especially warranted when interventions may have unintended negative consequences, such as when efforts to avoid exposure to air pollutants lead to reduced physical activity or when there is evidence that dietary supplements, such as antioxidants, have potential adverse health effects. These potential complications of partially effective personal interventions to reduce exposure or

  7. Scattering study at free air ionization chamber diaphragm

    International Nuclear Information System (INIS)

    Santos, Alexandre Lo Bianco dos

    2011-01-01

    The maim of this work consisted in the assessment of the correction factor for air kerma, due to scattered radiation in the diaphragm of the free-air ionization chamber model 481. LNMRl measurements were made to acquire x-ray spectra corresponding to the Qualities RQR-M, described in IEC 61627 standards (2005). These spectra were used as input data in the MC simulations. The operational range of energy spectra provide up to 35 keV. This energy range is typically used in diagnostic radiology, although there is not primary standard for air kerma. The determination of this factor is a fundamental process in the primary standardization of the air kerma. These factors were obtained by computer simulation using the Penelope code. The results are k RQR-M1 =0,9946, k RQR -M2 =0,9932, k RQR-M3 =0,9978 and k RQR-M4 =0,9885; with uncertainties of 0,007 and coverage factor equal to 2. lt can be concluded that, with respect to the diaphragm, the chamber can be used in the primary standard of air kerma. (author)

  8. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  9. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  10. Air pollution and vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M

    1975-01-01

    Although the direct effects of each air pollutant have been fairly well studied for specific species of plants used as indicators, studies on the synecological level have not been done. Clement's communities can be used as indicators. The effects of air pollution should be studied as one in a complex of factors. The characteristic features of biological indicators are described in detail with emphasis on applying the results to human beings in polluted environments. The methods of determining the effects of pollution are described, using a community phytometer and remote sensing methods. Directly connecting the level of air pollution to the wilting of trees in general is dangerous unless it is a matter of an acute episode.

  11. Air-Sea Interaction

    Science.gov (United States)

    Csanady, G. T.

    2001-03-01

    In recent years air-sea interaction has emerged as a subject in its own right, encompassing small-scale and large-scale processes in both air and sea. Air-Sea Interaction: Laws and Mechanisms is a comprehensive account of how the atmosphere and the ocean interact to control the global climate, what physical laws govern this interaction, and its prominent mechanisms. The topics covered range from evaporation in the oceans, to hurricanes, and on to poleward heat transport by the oceans. By developing the subject from basic physical (thermodynamic) principles, the book is accessible to graduate students and research scientists in meteorology, oceanography, and environmental engineering. It will also be of interest to the broader physics community involved in the treatment of transfer laws, and thermodynamics of the atmosphere and ocean.

  12. The Clean Air Act

    International Nuclear Information System (INIS)

    Coburn, L.L.

    1990-01-01

    The Clean Air Act amendments alter the complex laws affecting atmospheric pollution and at the same time have broad implications for energy. Specifically, the Clean Air Act amendments for the first time deal with the environmental problem of acid deposition in a way that minimizes energy and economic impacts. By relying upon a market-based system of emission trading, a least cost solution will be used to reduce sulfur dioxide (SO 2 ) emissions by almost 40 percent. The emission trading system is the centerpiece of the Clean Air Act (CAA) amendments effort to resolve energy and environmental interactions in a manner that will maximize environmental solutions while minimizing energy impacts. This paper will explore how the present CAA amendments deal with the emission trading system and the likely impact of the emission trading system and the CAA amendments upon the electric power industry

  13. Nutritional Solutions to Reduce Risks of Negative Health Impacts of Air Pollution

    OpenAIRE

    Szabolcs Péter; Fernando Holguin; Lisa G. Wood; Jane E. Clougherty; Daniel Raederstorff; Magda Antal; Peter Weber; Manfred Eggersdorfer

    2015-01-01

    Air pollution worldwide has been associated with cardiovascular and respiratory morbidity and mortality, particularly in urban settings with elevated concentrations of primary pollutants. Air pollution is a very complex mixture of primary and secondary gases and particles, and its potential to cause harm can depend on multiple factors?including physical and chemical characteristics of pollutants, which varies with fine-scale location (e.g., by proximity to local emission sources)?as well as l...

  14. Intracardiac air- the "hospital killer' identified? | Smith | South African ...

    African Journals Online (AJOL)

    Venous access is an essential part of caring for the sick neonate. The primary problem with catheters, whether peripherally or centrally placed, is the difficulty in maintaining them, the development of phlebitis and systemic infection, and fluid extravasation. A lesser known complication is the development of venous air ...

  15. Unit for air decontamination

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  16. Air quality risk management.

    Science.gov (United States)

    Williams, Martin L

    2008-01-01

    Rather than attempt to provide a comprehensive account of air quality risk assessment, as might be found in a textbook or manual, this article discusses some issues that are of current importance in the United Kingdom and the rest of Europe, with special emphasis on risk assessment in the context of policy formulation, and emerging scientific knowledge. There are two pollutants of particular concern and that both pose challenges for risk assessment and policy, and they are particulate matter (PM) and ozone. The article describes some issues for health risk assessment and finally some forward-looking suggestions for future approaches to air quality management.

  17. Liquid air cycle engines

    Science.gov (United States)

    Rosevear, Jerry

    1992-01-01

    Given here is a definition of Liquid Air Cycle Engines (LACE) and existing relevant technologies. Heat exchanger design and fabrication techniques, the handling of liquid hydrogen to achieve the greatest heat sink capabilities, and air decontamination to prevent heat exchanger fouling are discussed. It was concluded that technology needs to be extended in the areas of design and fabrication of heat exchangers to improve reliability along with weight and volume reductions. Catalysts need to be improved so that conversion can be achieved with lower quantities and lower volumes. Packaging studies need to be investigated both analytically and experimentally. Recycling with slush hydrogen needs further evaluation with experimental testing.

  18. Air the excellent canopy

    CERN Document Server

    Fahy, F

    2013-01-01

    We take it for granted, but without it we perish and if we continue to abuse it, it may kill us in the end. This fascinating text provides an understanding and appreciation of the role that air plays in our environment and its importance in relation to human life and technology. Aimed at those who are scientifically curious but who have no specialist training, it contains no mathematical equations and relies upon the qualitative descriptions and analogies to explain the more technical parts of the text together with simple home experiments to illustrate a range of air-based phenomena. Liberall

  19. Air condensation plants

    International Nuclear Information System (INIS)

    Kelp, F.; Pohl, H.H.

    1978-01-01

    In this plant the steam is distributed by a ventilator from the bottom to symmetrically fixed, inclined cooling elements with tubes. The upper part of the current side of the cooling elements as well as the bottom part of the outflow side can be covered by cover plates via a control circuit. This way, part of the air amount is deviated and in case of unfavourable atmospheric conditions (cold) the air is heated. This heating is enough to prevent freezing of the condensate on the cooling tubes. (DG) [de

  20. Automatic programmable air ozonizer

    International Nuclear Information System (INIS)

    Gubarev, S.P.; Klosovsky, A.V.; Opaleva, G.P.; Taran, V.S.; Zolototrubova, M.I.

    2015-01-01

    In this paper we describe a compact, economical, easy to manage auto air ozonator developed at the Institute of Plasma Physics of the NSC KIPT. It is designed for sanitation, disinfection of premises and cleaning the air from foreign odors. A distinctive feature of the developed device is the generation of a given concentration of ozone, approximately 0.7 maximum allowable concentration (MAC), and automatic maintenance of a specified level. This allows people to be inside the processed premises during operation. The microprocessor controller to control the operation of the ozonator was developed

  1. Numerical Analysis of Thermal Mixing in a Swirler-Embedded Line-Heater for Flow Assurance in Subsea Pipelines

    Directory of Open Access Journals (Sweden)

    Jang Min Park

    2015-02-01

    Full Text Available Flow assurance issue in subsea pipelines arises mainly due to hydrate plugs. We present a new line-heater for prevention of hydrate plug formation in subsea pipelines. The line heater has modular compact design where an electrical heater and a swirl generator are embedded inside the housing pipe so that the stream can be heated efficiently and homogeneously. In this paper, flow and heat transfer characteristics of the line heater are investigated numerically, with a particular emphasis on the mixing effect due to the swirl generator.

  2. Air pollution control technologies and their interactions

    Energy Technology Data Exchange (ETDEWEB)

    Nalbandian, H. [IEA Clean Coal Centre, London (United Kingdom)

    2004-11-01

    A large number of coal-fired power stations have been fitted/retrofitted with dedicated air pollutant control technologies. Experience shows that these technologies can have complex interactions and can impact each other as well as balance of plant, positively and/or negatively. Particulate matter (PM) is usually captured with electrostatic precipitators (ESPs) and fabric filters (FF). These technologies are efficient and reliable but their performance may be affected by modifying operating conditions and introducing primary measures for NOx reduction. Flue gas desulphurisation (FGD) systems for SO{sub 2} control have been installed in many facilities with the most popular technology being the wet limestone/gypsum scrubber. FGD use can decrease particulate matter and mercury emissions which is a major issue in the USA, cause an increase in carbon dioxide emissions, and in solids by-product. Primary measures such as low NOx burners (LNBs) and overfire air (OFA) minimise NOx formation but can increase carbon in ash (CIA) which can cause problems with fly ash sales but may also improve mercury capture. Reducing NOx emissions with selective catalytic reduction (SCR) can result in a decrease in particulate matter, an increase in SO{sub 3} emissions and trace increase in NH{sub 3}. This can cause fouling and loss of performance of the air preheater, due to the formation of ammonium sulphates. One way of alleviating this is improved soot-blowing and other cleaning capabilities. This report studies these and other interactions between existing air pollution control technologies in pulverised coal fired power plants. 249 refs., 13 figs., 18 tabs.

  3. Carbon Capture Methods and Relative Competitiveness of Primary Energies

    International Nuclear Information System (INIS)

    Amigues, Jean-Pierre; Lafforgue, Gilles; Moreaux, Michel

    2016-01-01

    We characterise the optimal exploitation paths of two primary energies (coal and solar) that supply the energy needs of two sectors. Sector 1 can reduce its carbon emissions at a reasonable cost thanks to a CCS device. Sector 2 has access only to air capture technology, but at a significantly higher cost. We assume that the atmospheric carbon stock cannot exceed a given ceiling. We show that the optimal approach consists in, first, fully capturing sector-1 emissions before the ceiling is reached and, second, deploying air capture to partially abate sector-2 emissions. The optimal carbon tax should increase in the pre-ceiling phase then decline in stages to zero

  4. Difficult colonoscopy: air, carbon dioxide, or water insufflation?

    Science.gov (United States)

    Chaubal, Alisha; Pandey, Vikas; Patel, Ruchir; Poddar, Prateik; Phadke, Aniruddha; Ingle, Meghraj; Sawant, Prabha

    2018-04-01

    This study aimed to compare tolerance to air, carbon dioxide, or water insufflation in patients with anticipated difficult colonoscopy (young, thin, obese individuals, and patients with prior abdominal surgery or irradiation). Patients with body mass index (BMI) less than 18 kg/m 2 or more than 30 kg/m 2 , or who had undergone previous abdominal or pelvic surgeries were randomized to air, carbon dioxide, or water insufflation during colonoscopy. The primary endpoint was cecal intubation with mild pain (less than 5 on visual analogue scale [VAS]), without use of sedation. The primary end point was achieved in 32.7%, 43.8%, and 84.9% of cases with air, carbon dioxide and water insufflation ( P carbon dioxide, and water insufflation ( P carbon dioxide for pain tolerance. This was seen in the subgroups with BMI 30 kg/m 2 .

  5. A review on the thermal hydraulic characteristics of the air-cooled

    Indian Academy of Sciences (India)

    In this paper, a review is presented on the experimental investigations and the numerical simulations performed to analyze the thermal-hydraulic performance of the air-cooled heat exchangers. The air-cooled heat exchangers mostly consist of the finned-tube bundles. The primary role of the extended surfaces (fins) is to ...

  6. Air and Weather Seychelles Integrated Science. [Teacher and Pupil Booklets]. Unit 2.

    Science.gov (United States)

    Brophy, M.; Fryars, M.

    Seychelles Integrated Science (SIS), a 3-year laboratory-based science program for students (ages 11-15) in upper primary grades 7, 8, and 9, was developed from an extensive evaluation and modification of previous P7-P9 materials. This P7 SIS unit focuses on: (1) the importance of air and air pressure in students' everyday lives; (2) oxidation…

  7. Emission of formaldehyde by particleboard : effect of ventilation rate and loading on air-contamination levels

    Science.gov (United States)

    George E. Myers; Muneo Nagaoka

    1981-01-01

    Dynamic tests for determining the formaldehyde emission behavior of UF-bonded boards involve the measurement of formaldehyde concentration in the air within a vessel which contains a specified board loading L (m2 of board area per m3 of vessel free volume) and is being ventilated at a specified air exchange rate N (hr.-1). Such tests constitute a primary...

  8. 77 FR 58076 - Revisions to the California State Implementation Plan, South Coast Air Quality Management District

    Science.gov (United States)

    2012-09-19

    ... the California State Implementation Plan, South Coast Air Quality Management District AGENCY... the South Coast Air Quality Management District (SCAQMD) portion of the California State... Quality Standards (NAAQS). The revisions to the primary and secondary Lead NAAQS were to provide increased...

  9. Vegetation and other development options for mitigating urban air pollution impacts

    Science.gov (United States)

    Richard Baldauf; David J. Nowak

    2014-01-01

    While air pollution control devices and programs are the primary method of reducing emissions, urban air pollution can be further mitigated through planning and design strategies, including vegetation preservation and planting, building design and development, installing roadside and near-source structures, and modifying surrounding terrain features.

  10. Design Fabrication And Partial-Analysis Of A 2-Wheeler Prototype That Runs On Compressed Air

    OpenAIRE

    P Vinay; Srivatsa G R; Venkatesh Datta; Dinesh Kumar A; Ramesha N; Dr. H K Govindaraju

    2015-01-01

    Abstract The primary objective of the project is to create a prototype of a purely air powered motorcycle by retrofitting its internal combustion engine to run on compressed air. Firstly the conventional spark plug was replaced with a solenoid valve. The solenoid valve was initially actuated using a reed switch and magnet duo but then later replaced with an optical crank position sensor circuit due to reasons that include lack of control over the amount of air injected during each stroke and ...

  11. Effects of air pollution on general practitioner consultations for upper respiratory diseases in London

    OpenAIRE

    Hajat, S; Anderson, H; Atkinson, R; Haines, A; Seaton, A.

    2002-01-01

    Objectives: Few published studies have examined the effect of air pollution on upper respiratory conditions. Furthermore, most epidemiological studies on air pollution focus on mortality or hospital admissions as the main health outcomes, but very rarely consider the effect in primary care. If pollution effects do exist then the public health impact could be considerable because of the many patient contacts involved. We investigated the relation between air pollution and upper respiratory dis...

  12. Localization of primary aldosteronism

    International Nuclear Information System (INIS)

    Pagny, J.Y.; Chatellier, G.; Raynaud, A.; Plouin, P.F.; Corvol, P.

    1988-01-01

    After diagnosis of primary aldosteronism on the basis of biochemical evidence, the detection of the tumour is of crucial importance in the management of the disease. The efficacy of CT-Scan, Iodo-Cholesterol Scintigraphy, digitalized phlebography, adrenal vein sampling for steroid measurements (AVS), and Nuclear Magnetic Resonance (NMR) in 160 hypertensive patients with primary aldosteronism was reviewed. Diagnosis of Conn's adenoma (n=96) or Adrenal Hyperplasia (n=40) was confirmed by surgery or at least two concordant tumour localization tests. Scintigraphy gave a correct diagnosis in 53% of the 51 exams, CT-Scan in 82% of the 85 exams, and phlebography in 79% of 61 exams. Plasma Aldosterone/ Cortisol ratio was 5 times higher on the side of adenoma in 55% of the 47 cases but this ratio was also present in 23% of 22 patients with adrenal hyperplasia. Each procedure exhibited few false positive and false negative cases. NMR performed in 15 patients with Conn's adenoma identified all the cases. But tumours displayed a signal close to the liver signal and identical to the normal adrenal. These results and the risk of invasive procedure (failure of catheterization of the right adrenal vein (n=6) and adrenal haematoma (n=2) lead to propose a schema of exploration of patients with primary aldosteronism. The CT-Scan could be performed at the first step once the biological diagnosis confirmed. Phlebography and AVS will be performed only if tumour was less than 1 cm at the CT-Scan despite important biological abnormalities. This schema requires to be validated by a prospective evaluation [fr

  13. Modeling green infrastructure land use changes on future air ...

    Science.gov (United States)

    Green infrastructure can be a cost-effective approach for reducing stormwater runoff and improving water quality as a result, but it could also bring co-benefits for air quality: less impervious surfaces and more vegetation can decrease the urban heat island effect, and also result in more removal of air pollutants via dry deposition with increased vegetative surfaces. Cooler surface temperatures can also decrease ozone formation through the increases of NOx titration; however, cooler surface temperatures also lower the height of the boundary layer resulting in more concentrated pollutants within the same volume of air, especially for primary emitted pollutants (e.g. NOx, CO, primary particulate matter). To better understand how green infrastructure impacts air quality, the interactions between all of these processes must be considered collectively. In this study, we use a comprehensive coupled meteorology-air quality model (WRF-CMAQ) to simulate the influence of planned land use changes that include green infrastructure in Kansas City (KC) on regional meteorology and air quality. Current and future land use data was provided by the Mid-America Regional Council for 2012 and 2040 (projected land use due to population growth, city planning and green infrastructure implementation). These land use datasets were incorporated into the WRF-CMAQ modeling system allowing the modeling system to propagate the changes in vegetation and impervious surface coverage on meteoro

  14. Teacher of primary English

    CERN Multimedia

    2003-01-01

    Part-time teacher of primary English needed for September 2003 to teach English National Curriculum (KS2) and NLS to mother tongue or good second language English-speakers aged 7-10. 4 hours contact time per week, team planning, marking and meetings. Candidates should be English mother tongue qualified teachers, confident, flexible classroom practitioners and team players. For further details and how to apply see http://enpferney.org/staff_vacancies.htm English National Programme, Lycée International, Ferney-Voltaire (http://enpferney.org/)

  15. Primary isolated hepatic tuberculosis

    International Nuclear Information System (INIS)

    Sheikh, A.S.F.; Qureshi, I.H.; Saba, K.; Bukhari, M.H.

    2013-01-01

    Isolated hepatic tuberculosis without pulmonary or bowel involvement is a diagnostic challenge and can cause considerable morbidity. A young lady from Lahore presented with fever, pain in right hypochondria, nausea and weight loss. CT scan of abdomen showed multiple small hypodense non-enhancing lesions and a heterogeneous texture of liver. Biopsy confirmed the diagnosis of hepatic tuberculosis. It was concluded a case of isolated hepatic tuberculosis without evidence of other primary sites involvement. It is important to consider tuberculosis in the differential diagnosis when suspecting lymphoproliferative or metastatic diseases in a patient with vague symptoms and abnormal hepatic texture on CT. (author)

  16. PRIMARY CARIES: AN OVERVIEW

    Directory of Open Access Journals (Sweden)

    Gaurav Solanki

    2012-01-01

    Full Text Available Primary caries is an initial lesions produced by direct extension from an external surface. Dental caries is called as tooth decay or a cavity is a disease in which bacterial processes changes carbohydrate to acid which than dematerializes the hard tooth structure like enamel, dentin and cementum. Streptococcus mutans and Lactobacillus are the bacteria responsible for the dental caries by acid production. This article throws light on the dental caries disease, its sign and symptoms, treatment and prevention of it. A review of some patents on dental caries is also provided that summarizes the recent technical advancements taken place in this area.

  17. Primary cutaneous lymphoma

    International Nuclear Information System (INIS)

    Nguyen, M. Connie; Cleary, Sean F.; Hoppe, Richard T.

    1995-01-01

    Purpose: A retrospective review analyzed the survival and freedom from relapse of patients with stage IE or IIE primary cutaneous lymphoma (non mycosis fungoides) after treatments with radiation therapy alone (XRT), chemotherapy alone (RX) or combined modality therapy (CMT). Methods and Materials: Fifty two patients with stage IE-IIE cutaneous lymphoma treated at Stanford University Hospital were reviewed. The median age was 57, with a range of 26 to 94 and a male to female ratio of 1.21:1. Patients were staged according to the Ann Arbor System. Pathology was classified according to the Working Formulation. Treatment outcomes were compared using Kaplan-Meier survival curves with a Gehan p-value test. Results: The follow up range was 6 months to 22 years (median 7 years.) Twenty one percent of patients had low grade, 63% had intermediate grade and 15% had high grade lymphoma. The most common histologic subtype was diffuse large cell lymphoma Thirty two patients received radiation alone as initial treatment and sixteen patients received combined modality as initial treatment. Four patients received chemotherapy alone. The only significant prognostic factor for survival was the stage at diagnosis. Patients with stage IE disease had a longer actuarial survival (5-yr=79%, 10-yr=71%), as compared to those with stage IIE (5-yr=49%, 10-yr=33%), (p=0.029). The only significant prognostic factor for freedom from relapse was the initial treatment. Initial combined modality treatment lead to a longer freedom from relapse compared to patients treated with radiation alone (p=0.002), (median 5 years vs. 1.2 years). Despite this, the actuarial overall survival in the combined modality group and the radiation alone group are similar (median survival 7.7 and 8 years). The efficacy of either radiation or chemotherapy as salvage treatment after radiation failure was equivalent and both salvage treatments lead to equally long survival and freedom from second relapse. Conclusion

  18. Bellefonte primary containment structure

    International Nuclear Information System (INIS)

    Olyniec, J.H.

    1981-01-01

    Construction of the reactor building primary containment structure at the Bellefonte Nuclear Plant involved several specialized construction techniques. This two unit plant is one of the nine nuclear units at six different sites now under construction by the Tennessee Valley Authority (TVA). The post-Tensioned, cast-in-place interior steel lined containment structure is unique within TVA. Problems during construction were identified at weekly planning meetings, and options were discussed. Close coordination between craft supervisors and on-site engineering personnel drew together ''hands-on''experience and technical background. Details of the construction techniques, problems, and solutions are presented

  19. Primary Carnitine Deficiency

    DEFF Research Database (Denmark)

    Rasmussen, Jan; Hougaard, David M; Sandhu, Noreen

    2017-01-01

    Primary carnitine deficiency (PCD) causes low levels of carnitine in patients potentially leading to metabolic and cardiac symptoms. Newborn screening for PCD is now routine in many countries by measuring carnitine levels in infants. In this study we report Apgar scores, length and weight...... scores, length and weight compared to controls. Newborns with PCD and newborns born to mothers with PCD had significantly lower levels of free carnitine (fC0) than controls. Screening algorithms focusing only on fC0 had a high rate of detection of newborns with PCD. Sample collection 4-9 days after birth...

  20. Aspirin for Primary Prevention.

    Science.gov (United States)

    Richman, Ilana B; Owens, Douglas K

    2017-07-01

    Aspirin reduces the risk of nonfatal myocardial infarction and stroke, and the risk of colorectal cancer. Aspirin increases the risk of gastrointestinal and intracranial bleeding. The best available evidence supports initiating aspirin in select populations. In 2016, the US Preventive Services Task Force recommended initiating aspirin for the primary prevention of both cardiovascular disease and colorectal cancer among adults ages 50 to 59 who are at increased risk for cardiovascular disease. Adults 60 to 69 who are at increased cardiovascular disease risk may also benefit. There remains considerable uncertainty about whether younger and older patients may benefit. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Primary cutaneous lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, M Connie; Cleary, Sean F; Hoppe, Richard T

    1995-07-01

    Purpose: A retrospective review analyzed the survival and freedom from relapse of patients with stage IE or IIE primary cutaneous lymphoma (non mycosis fungoides) after treatments with radiation therapy alone (XRT), chemotherapy alone (RX) or combined modality therapy (CMT). Methods and Materials: Fifty two patients with stage IE-IIE cutaneous lymphoma treated at Stanford University Hospital were reviewed. The median age was 57, with a range of 26 to 94 and a male to female ratio of 1.21:1. Patients were staged according to the Ann Arbor System. Pathology was classified according to the Working Formulation. Treatment outcomes were compared using Kaplan-Meier survival curves with a Gehan p-value test. Results: The follow up range was 6 months to 22 years (median 7 years.) Twenty one percent of patients had low grade, 63% had intermediate grade and 15% had high grade lymphoma. The most common histologic subtype was diffuse large cell lymphoma Thirty two patients received radiation alone as initial treatment and sixteen patients received combined modality as initial treatment. Four patients received chemotherapy alone. The only significant prognostic factor for survival was the stage at diagnosis. Patients with stage IE disease had a longer actuarial survival (5-yr=79%, 10-yr=71%), as compared to those with stage IIE (5-yr=49%, 10-yr=33%), (p=0.029). The only significant prognostic factor for freedom from relapse was the initial treatment. Initial combined modality treatment lead to a longer freedom from relapse compared to patients treated with radiation alone (p=0.002), (median 5 years vs. 1.2 years). Despite this, the actuarial overall survival in the combined modality group and the radiation alone group are similar (median survival 7.7 and 8 years). The efficacy of either radiation or chemotherapy as salvage treatment after radiation failure was equivalent and both salvage treatments lead to equally long survival and freedom from second relapse. Conclusion

  2. PRIMARY SCHOOL TEACHER

    CERN Multimedia

    Madeleine Dittus

    2002-01-01

    For January 2003, the A.P.E.G. has an opening for a primary school teacher in the German national language program. The position requires one afternoon of teaching (13:30 till 16:30) every Tuesday at the Collège in Prévessin. The candidate should be a native speaker of German and have some knowledge of French. If you are interested, please send your CV, a copy of your diploma, and a short letter of motivation, until December 9th, to the following address. Madeleine Dittus Présidente A.P.E.G. 5, La vie Destraz 01630 St. Genis-Pouilly (France)

  3. Assessment of heat loss for RSG-GAS primary cooling system

    International Nuclear Information System (INIS)

    Dibyo, S.

    1998-01-01

    Heat Loss is part term of energy balance equation of system, therefore heat loss very important thing in the thermal dynamic analysis. Heat energy loosed from the surface pipe to the air in the room was calculated. Heat energy pass through by conduction, convection and radiation. The convection process are caused by moving of air density, i.e up flow of the hot air return to be down flow. The heat transfer phenomenon could be determined by empirical correlation of Heilman. The primary cooling system is consisted to the 3 zone : 1). Zone of (safety valves-heat exchanger), 2). Zone of heat exchanger surfaces, 3). Zone of heat exchanger-reactor pool. By using input data of air temperature are about 25 o C, temperature of primary coolant about 45 o C, The heat Loss along the pipes to the air are 23.9 k watt or 0.1%

  4. LWR primary coolant pipe rupture test rig

    International Nuclear Information System (INIS)

    Yoshitoshi, Shyoji

    1978-01-01

    The rupture test rig for primary coolant pipes is constructed in the Japan Atomic Energy Research Institute to verify the reliability of the primary coolant pipes for both PWRs and BWRs. The planned test items consisted of reaction force test, restraint test, whip test, jet test and continuous release test. A pressure vessel of about 4 m 3 volume, a circulating pump, a pressurizer, a heater, an air cooler and the related instrumentation and control system are included in this test rig. The coolant test condition is 160 kg/cm 2 g, 325 deg C for PWR test, and 70 kg/cm 2 g, saturated water and steam for BWR test, 100 ton of test load for the ruptured pipe bore of 8B Schedule 160, and 20 lit/min. discharge during 20 h for continuous release of coolant. The maximum pit internal pressure was estimated for various pipe diameters and time under the PWR and BWR conditions. The spark rupturing device was adopted for the rupture mechanics in this test rig. The computer PANAFACOM U-300 is used for the data processing. This test rig is expected to operate in 1978 effectively for the improvement of reliability of LWR primary coolant pipes. (Nakai, Y.)

  5. Pattern of Primary Nocturnal Enuresis in Primary School Children ...

    African Journals Online (AJOL)

    Pattern of Primary Nocturnal Enuresis in Primary School Children (First Grade) in ... The control group consisting of 100 age-matched non-enuretic children ... was insignificantly associated with a positive family history, family size or birth rank.

  6. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  7. Indoor Air Pollution

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Indoor Air Pollution - Danger at Home. N Pon Saravanan. General Article Volume 9 Issue 1 January 2004 pp 6-11. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0006-0011. Keywords.

  8. Can you see Air?

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 6. Can you see Air? Andal Narayanan Joseph Samuel Supurna Sinha. Classroom Volume 12 Issue 6 June 2007 pp 71-75. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/012/06/0071-0075 ...

  9. Russia air management program

    Energy Technology Data Exchange (ETDEWEB)

    Pace, T.G. [U.S. Environmental Protection Agency, NC (United States); Markin, S. [Ministry of Environmental Protection and Natural Resources, Moscow (Sweden); Kosenkova, S.V. [Volgograd Environmental Services Administration, Volgograd (Russian Federation)

    1995-12-31

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  10. Ames Air Revitalization

    Science.gov (United States)

    Huang, Roger Z.

    2015-01-01

    This is an informal presentation presented to the University of Colorado, Boulder Bioastronautics group seminar. It highlights the key focal areas of the Air Revitalization Group research over the past year, including progress on the CO2 Removal and Compression System, testing of CDRA drying bed configurations, and adsorption research.

  11. Modeling indoor air pollution

    National Research Council Canada - National Science Library

    Pepper, D. W; Carrington, David B

    2009-01-01

    ... and ventilation from the more popular textbooks and monographs. We wish to especially acknowledge Dr. Xiuling Wang, who diligently converted many of our old FORTRAN codes into MATLAB files, and also developed the COMSOL example files. Also we thank Ms. Kathryn Nelson who developed the website for the book and indoor air quality computer codes. We are grateful to ...

  12. Outdoor air Pollution

    CSIR Research Space (South Africa)

    Forbes, PBC

    2016-07-01

    Full Text Available This chapter focuses on the air pollutants which are generally found in the troposphere and does not provide detail on specific areas where atmospheric pollutants and atmospheric chemistry may differ from that generally found, such as in the arctic...

  13. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  14. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2013-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  15. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2012-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  16. Russia air management program

    International Nuclear Information System (INIS)

    Pace, T.G.; Markin, S.; Kosenkova, S.V.

    1995-01-01

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  17. Indoor Air Quality

    DEFF Research Database (Denmark)

    Selman, Ayser Dawod; Heiselberg, Per

    Overall purpose of the research is to provide an overview of the relevance and importance of various defined Indoor Air Quality (IAQ) parameters in a European perspective. Based on the report it should be possible to prioritize which countries to target for further activities as well as it should...

  18. Air quality conformity appendix.

    Science.gov (United States)

    2011-05-01

    Under the 1990 Clean Air Act Amendments (CAAA), because of the 8-hour ozone standard, Franklin, Delaware, Licking, Madison, Fairfield and Knox counties were designated as a basic nonattainment area for ozone in 2004. As a result of the PM 2.5 standar...

  19. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  20. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  1. Fast Air Temperature Sensors

    DEFF Research Database (Denmark)

    Hendricks, Elbert

    1998-01-01

    The note documents briefly work done on a newly developed sensor for making fast temperature measurements on the air flow in the intake ports of an SI engine and in the EGR input line. The work reviewed has been carried out in close cooperation with Civ. Ing. Michael Føns, the author (IAU...

  2. Russia air management program

    Energy Technology Data Exchange (ETDEWEB)

    Pace, T G [U.S. Environmental Protection Agency, NC (United States); Markin, S [Ministry of Environmental Protection and Natural Resources, Moscow (Sweden); Kosenkova, S V [Volgograd Environmental Services Administration, Volgograd (Russian Federation)

    1996-12-31

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  3. Decentralization in Air Transportation

    NARCIS (Netherlands)

    Udluft, H.

    2017-01-01

    In this work,we demonstrate that decentralized control can result in stable, efficient, and robust operations in the Air Transportation System. We implement decentralized control for aircraft taxiing operations and use Agent-Based Modeling and Simulation to analyze the resulting system behavior

  4. Indoor air quality research

    International Nuclear Information System (INIS)

    1986-01-01

    The various types of pollutant found in indoor air are introduced and the effects on the health of the occupants of buildings summarized. The ''sick'' building syndrome is described in detail and the need for further investigation into its causes and remedies is stressed. 8 tabs

  5. AIR POLLUTION AND HUMMINGBIRDS

    Science.gov (United States)

    A multidisciplinary team of EPA-RTP ORD pulmonary toxicologists, engineers, ecologists, and statisticians have designed a study of how ground-level ozone and other air pollutants may influence feeding activity of the ruby-throated hummingbird (Archilochus colubris). Be...

  6. Air Pollution Surveillance Systems

    Science.gov (United States)

    Morgan, George B.; And Others

    1970-01-01

    Describes atmospheric data monitoring as part of total airpollution control effort. Summarizes types of gaseous, liquid and solid pollutants and their sources; contrast between urban and rural environmental air quality; instrumentation to identify pollutants; and anticipated new non-wet chemical physical and physiochemical techniques tor cetection…

  7. Learning AirWatch

    CERN Document Server

    Dunkerley, Mark

    2015-01-01

    If you are a technical professional who wants to dive deeper into the functionality offered by AirWatch or manage the solution, then this book will help you choose the best set of configuration, device management, and monitoring options that you can use to effectively manage your EMM implementation.

  8. Primary iris leiomyoma.

    Science.gov (United States)

    Yeaney, Gabrielle A; Platt, Sean; Singh, Arun D

    Intraocular leiomyomas are uncommon and usually occur in the ciliary body. Primary leiomyoma of the iris is both rare and a difficult diagnosis to make, given melanocytic tumors are more common and may be amelanotic. The somewhat controversial diagnosis of iris leiomyoma requires further confirmation by immunohistochemistry and electron microscopy. Herein, we describe a 58-year-old man with a 2-mm round translucent pink lesion of the iris. The tumor was excised by sector iridectomy. Immunohistochemistry showed positivity for both smooth muscle actin and desmin and negativity for S-100, HMB45, SOX10, MelanA, CD31, CD34, and h-caldesmon. Epstein-Barr virus-associated smooth muscle tumor was excluded by chromogenic in situ hybridization-Epstein-Barr virus-encoded RNA. Ultrastructural analysis showed cytoplasmic myofilaments with focal fusiform densities and micropinocytotic vesicles. Our review of previous literature confirmed the unusual nature of this tumor. Primary iris leiomyoma should be considered in the differential of an amelanotic S-100-immunonegative iris tumor. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Imaging in primary osteosarcomas

    International Nuclear Information System (INIS)

    Davies, A.M.

    1998-01-01

    Osteosarcoma is the most common primary malignant bone tumour with the exception of myeloma. The majority of osteosarcoma cases arise within bone and are called conventional osteosarcoma. Intraosseous variants include telangiectatic, small-cell, low-grade intraosseous and cortical osteosarcoma. Less than 10% of osteosarcomas arise on the surface of bone and are subdivided into periosteal, high-grade surface and parosteal varieties. The imaging features of these subtypes of osteosarcoma are described and the impact on diagnosis highlighted. Using material from over 750 osteosarcomas treated at the author's centre, this article reviews the role of imaging in the management of this condition. Detection still relies principally on the conventional radiograph with bone scintigraphy and MR imaging useful in occult tumours. Establishing the radiological diagnosis depends on careful analysis of the radiographs, with particular attention paid to the nature and extent of bone destruction, periosteal new bone formation and matrix mineralization. The prudent radiologist will be wary of those bone conditions, such as stress fractures and osteomyelitis, which are frequently mistaken for osteosarcoma. Appropriate surgical staging requires MR imaging of the primary tumour to show the bony and soft tissue extent of the lesion and to confirm/exclude skip metastases and local lymph-node involvement. Staging should also include bone scintigraphy to confirm/exclude multiple lesions and chest CT to confirm/exclude pulmonary metastases. Following definitive surgery, imaging is used in the follow-up to monitor potential local recurrence and the development of pulmonary or osseous metastases. (orig.) [de

  10. [Normocalcemic primary hyperparathyroidism].

    Science.gov (United States)

    Spivacow, Francisco R; Sapag Durán, Ana; Zanchetta, María B

    2014-01-01

    This report shows our conclusions on the clinical, biochemical and densitometry characteristics of 35 normocalcemic primary hyperparathyroidism (PHPT) patients. This condition is defined by a high level of intact parathyroid hormone (iPTHI) with persistently normal serum and ionized calcium in the absence of secondary hyperparathyroidism. Our selection consisted of 30 women (90%) and 5 men (10%). The control group of 55 hypercalcemic patients with primary hyperparathyroidism included 51 women (93%) and 4 men (7%). The average age at diagnosis of normocalcemic PHPT was 61.4 ± 11.7 years and 56.4 ± 11.3 years in hypercalcemic PHPT. Besides the expected differences in serum calcium, ionized calcium, phosphorus and 24 h urinary calcium, we found no significant changes in other biochemical variables, and no differences in densitometry evaluations such as the presence of osteopenia or osteoporosis and the number of fractures in the two types of PHPT. But there was a significant difference in the presence of renal lithiasis between normocalcemic PHPT (11.4%) and clasic PHPT (49.1%) p < 0.0005, to some extent associated to the presence of hypercalciuria in classic PHPT. Two of the 35 patients with normocalcemic PHPT became classic hypercalcemic PHPT over a 4 year follow-up period. Our findings support the hypothesis that the normocalcemic PHPT could be an early stage of the classic PHPT, both having similar clinical effects to metabolic renal and bone levels.

  11. Asymptomatic Primary Hyperparathyroidism

    Science.gov (United States)

    Silverberg, Shonni J.; Walker, Marcella D.; Bilezikian, John P.

    2014-01-01

    The clinical profile of primary hyperparathyroidism (PHPT) as it is seen in the United States and most Western countries has evolved significantly over the past half century. The introduction of the multichannel serum autoanalyzer in the 1970s led to the recognition of a cohort of individuals with asymptomatic hypercalcemia, in whom evaluation led to the diagnosis of PHPT. The term “asymptomatic primary hyperparathyroidism” was introduced to describe patients who lack obvious signs and symptoms referable to either excess calcium or parathyroid hormone. Although it was expected that asymptomatic patients would eventually develop classical symptoms of PHPT, observational data suggest that most patients do not evolve over time to become overtly symptomatic. In most parts of the world, the asymptomatic phenotype of PHPT has replaced classical PHPT. This report is a selective review of data on asymptomatic PHPT: its demographic features, presentation and natural history, as well as biochemical, skeletal, neuromuscular, psychological, and cardiovascular manifestations. In addition, we will summarize available information on treatment indications and options for those with asymptomatic disease. PMID:23374736

  12. Air quality indicators

    International Nuclear Information System (INIS)

    Clench-Aas, Jocelyn; Guerreiro, Cristina; Bartonova, Alena

    1999-06-01

    This report proposes and describes in detail several air quality indicators that may be used to describe population exposure. The suggested indicators account for temporal and spatial patterns of pollution and movements of individuals between different micro-environments. The Air Quality Indicator /AQI) should represent both the spatial and temporal aspects of pollution exposure that may have important effects on health. Two indicators are needed, the Population Air Quality Indicator and the Individual Air Quality Indicator. Mean concentrations, 98th percentile and maximum values are the traditional indicators for estimating exposure. the temporal variability of PM-10 and NO 2 , however, is here described by means of: 1) The rate of change of pollution as the difference between two consecutive hourly values and of 2) episodes, described in terms of number, duration and winter episode period, maximum concentration in the episode and integrated episode exposure (episode AOT50/100). The spatial variation of AQIs can be described in several ways, e.g.: 1) Concentrations in neighbouring grid squares can be compared as an indication of spatial variation and 2) point estimates can be compared to grid values for a description of variation within a grid. Both methods are presented here. A test of the representativity of static point estimates for pollution exposure is to compare them to an estimate of air pollution exposure accounting for movements between different locations, obtained using diaries. The ultimate aim of AQIs is to describe the population exposure to ambient pollution. This is done by estimating the number of people exposed using different characteristics of AQIs. The data used to describe these indicators originates from dispersion modelling of short-term air pollution concentrations in Oslo. Two series of data are used. One represents hour-for hour concentrations in the 1 km 2 grid system covering the city of Oslo, winter 1994/95, calculated by the grid

  13. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  14. Nitrogen fluorescence in air for observing extensive air showers

    CERN Document Server

    Keilhauer, B; Fraga, M; Matthews, J; Sakaki, N; Tameda, Y; Tsunesada, Y; Ulrich, A

    2012-01-01

    Extensive air showers initiate the fluorescence emissions from nitrogen molecules in air. The UV-light is emitted isotropically and can be used for observing the longitudinal development of extensive air showers in the atmosphere over tenth of kilometers. This measurement technique is well-established since it is exploited for many decades by several cosmic ray experiments. However, a fundamental aspect of the air shower analyses is the description of the fluorescence emission in dependence on varying atmospheric conditions. Different fluorescence yields affect directly the energy scaling of air shower reconstruction. In order to explore the various details of the nitrogen fluorescence emission in air, a few experimental groups have been performing dedicated measurements over the last decade. Most of the measurements are now finished. These experimental groups have been discussing their techniques and results in a series of \\emph{Air Fluorescence Workshops} commenced in 2002. At the 8$^{\\rm{th}}$ Air Fluoresc...

  15. Air toxics regulatory issues facing urban settings

    Energy Technology Data Exchange (ETDEWEB)

    Olden, K.; Guthrie, J. [National Institute of Environmental Health Sciences, Research Triangle Park, NC (United States)

    1996-10-01

    Biomarker research does not exist in isolation. Its usefulness can only be realized when it is translated into prevention strategies to protect public health. In the context of air toxics, these prevention strategies begin with the development of regulatory standards derived from risk assessment schemes. The Clean Air Act Amendments of 1990 list 189 air toxics, including many volatile organics, metals, and pesticides. The National Institute of Environmental Health Sciences (NIEHS), through its affiliation with the National Toxicology Program, has generated toxicity and carcinogenicity data on more than 100 of these air toxics. The NIEHS extramural and intramural research portfolios support a variety of projects that develop and validate biomarkers for use in environmental health science and risk assessment. Biomarkers have a tremendous potential in the areas of regulating air toxics and protecting public health. Risk assessors need data provided by biomarkers of exposure, biomarkers of close/pharmacokinetics, biomarkers of susceptibility or individual variability, and biomarkers of effects. The greatest benefit would be realized if biomarkers could be employed in four areas of primary and secondary prevention. The first is the use of biomarkers to enhance extrapolation of animal data to human exposure situations in establishing risk standards. The second is the use of biomarkers that assess noncancer, as well as cancer, end points. Important health end points include pulmonary dysfunction, immunotoxicity, and neurotoxicity. Third, biomarkers that serve as early warning signs to detect intermediate effects would enhance our ability to design timely and cost-effective intervention strategies. Finally, biomarkers used to evaluate the effectiveness of intervention strategies both in clinical and regulatory settings, would enable us to ensure that programs designed to protect public health do, in fact, achieve the desired outcome. 9 refs., 2 tabs.

  16. Indoor air - assessment: Methods of analysis for environmental carcinogens

    International Nuclear Information System (INIS)

    Peterson, M.R.; Naugle, D.F.; Berry, M.A.

    1990-06-01

    The monograph describes, in a general way, published sampling procedures and analytical approaches for known and suspected carcinogens. The primary focus is upon carcinogens found in indoor air, although the methods described are applicable to other media or environments. In cases where there are no published methods for a particular pollutant in indoor air, methods developed for the workplace and for ambient air are included since they should be adaptable to indoor air. Known and suspected carcinogens have been grouped into six categories for the purposes of this and related work. The categories are radon, asbestos, organic compounds, inorganic species, particles, and non-ionizing radiation. Some methods of assessing exposure that are not specific to any particular pollutant category are covered in a separate section. The report is the fifth in a series of EPA/Environmental Criteria and Assessment Office Monographs

  17. COMMUNITY MEDICINE & PRIMARY HEALTH CARE

    African Journals Online (AJOL)

    Journal of Community Medicine and Primary Health Care. ... Ladoke Akintola University of Technology, PMB 4400, Osogbo, Osun State. ... weak management and poor adherence to the basic infrastructure e.g. primary, secondary and tertiary.

  18. Bezafibrate for primary biliary cirrhosis

    DEFF Research Database (Denmark)

    Rudic, Jelena S; Poropat, Goran; Krstic, Miodrag N

    2012-01-01

    Treatment of primary biliary cirrhosis is complicated. There are studies suggesting that bezafibrate, alone or in combination with ursodeoxycholic acid (UDCA), is effective in the treatment of primary biliary cirrhosis, but no systematic review has summarised the evidence yet....

  19. BR-5 primary circuit decontamination

    International Nuclear Information System (INIS)

    Efimov, I.A.; Nikulin, M.P.; Smirnov-Averin, A.P.; Tymosh, B.S.; Shereshkov, V.S.

    1976-01-01

    Results and methodology of steam-water and acid decontamination of the primary coolant circuit SBR-5 reactor in 1971 are discussed. Regeneration process in a cold trap of the primary coolant circuit is discussed

  20. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  1. EN EL AIRE / In the air

    Directory of Open Access Journals (Sweden)

    Andrés López Fernández

    2011-11-01

    Full Text Available RESUMEN En el aire es un viaje a la primera mitad del siglo XX que nos tratará de acercar la frescura y oportunidad de las calles corredor y los jardines en la ciudad vertical. Se inicia en 1909 en Nueva York, con la publicación por la revista Life de La Torre del Globo, se acerca al Inmueble-Villas y al Plan Obus para Argel de Le Corbusier, y finaliza en 1952 con el proyecto para el conjunto residencial de Golden Lane en Londres de A. y P. Smithson. Fragmentos para la ciudad vertical que se construía sobre papel, tras el espejo, paralela en el tiempo, pero muy distinta a la ciudad real, con el objetivo entre otros de integrar arquitectura y naturaleza. Esas propuestas siguen teniendo hoy un gran valor, en un panorama en que el espacio público ligado a la vivienda colectiva, prácticamente ha desaparecido, y el esfuerzo que se demanda al arquitecto se centra, en tejer a modo de encaje de bolillos, una fachada que envuelva un programa de vivienda, funcional y espacialmente obsoleto. SUMMARY In the air, is a journey to the first half of the twentieth century that will try to bring us to the freshness and opportunity of the corridor streets and gardens in the vertical city. It begins in 1909 in New York, with the publication in Life magazine of the Globe Tower, it approaches the Immeubles-Villas and Plan Obus for Algiers by Le Corbusier, and ends in 1952 with the project for the Golden Lane Estate residential complex in London, by A. and P. Smithson. Fragments for the vertical city that was constructed on paper, behind the mirror, parallel in time, but was very different from the real city, with the aim, inter alia, of integrating architecture and nature. These proposals continue to have great value today, in a scenario where the public space linked to the collective home has virtually disappeared, and the effort that is demanded of the architect focuses on weaving a facade like bobbin lace around a functionally and spatially obsolete housing

  2. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  3. Air-cooled, hydrogen-air fuel cell

    Science.gov (United States)

    Shelekhin, Alexander B. (Inventor); Bushnell, Calvin L. (Inventor); Pien, Michael S. (Inventor)

    1999-01-01

    An air-cooled, hydrogen-air solid polymer electrolyte (SPE) fuel cell with a membrane electrode assembly operatively associated with a fluid flow plate having at least one plate cooling channel extending through the plate and at least one air distribution hole extending from a surface of the cathode flow field into the plate cooling channel.

  4. Primary Prevention With Statins

    DEFF Research Database (Denmark)

    Mortensen, Martin B; Afzal, Shoaib; Nordestgaard, Børge G

    2015-01-01

    BACKGROUND: Guidelines recommend initiating primary prevention for atherosclerotic cardiovascular disease (ASCVD) with statins based on absolute ASCVD risk assessment. Recently, alternative trial-based and hybrid approaches were suggested for statin treatment eligibility. OBJECTIVES: This study...... the population studied, 42% were eligible for statin therapy according to the 2013 American College of Cardiology/American Heart Association (ACC/AHA) risk assessment and cholesterol treatment guidelines approach, versus 56% with the trial-based approach and 21% with the hybrid approach. Among these statin......-eligible subjects, the ASCVD event rate per 1,000 person-years was 9.8, 6.8, and 11.2, respectively. The ACC/AHA-recommended absolute risk score was well calibrated around the 7.5% 10-year ASCVD risk treatment threshold and discriminated better than the trial-based or hybrid approaches. Compared with the ACC...

  5. Primary care guidelines

    DEFF Research Database (Denmark)

    Ijäs, Jarja; Alanen, Seija; Kaila, Minna

    2009-01-01

    OBJECTIVE: To describe the adoption of the national Hypertension Guideline in primary care and to evaluate the consistency of the views of the health centre senior executives on the guideline's impact on clinical practices in the treatment of hypertension in their health centres. DESIGN: A cross...... Guideline. RESULTS: Data were available from 143 health centres in Finland (49%). The views of head physicians and senior nursing officers on the adoption of the Hypertension Guideline were not consistent. Head physicians more often than senior nursing officers (44% vs. 29%, p ...: Hypertension Guideline recommendations that require joint agreements between professionals are less often adopted than simple, precise recommendations. More emphasis on effective multidisciplinary collaboration is needed....

  6. Adrenal incidentalomas. Primary hyperaldosteronism

    International Nuclear Information System (INIS)

    Murat, A.; Dupas, B.; Zenatti, M.; Aupetit-Faisant, B.; Tenenbaum, F.; Tabarin, A.; Barrat, J.L.; Gosse, P.; Olivier-Puel, F.; Leprat, F.; Trouette, H.; Laurent, F.; Roger, P.

    1993-01-01

    Adrenal incidentalomas are masses incidentally discovered at X rays, ultrasound or MRI examination of the abdomen. In 100 CT scans, one can expect to find two incidentalomas on average. The article by Murat and Dupas is dealing with the strategy of biological, morphological and scintigraphic examinations to be performed in such patients, to assess whether the tumor is of a benign or a malignant nature. Zenatti et al propose a detailed exploration of the aldosterone pathways, since adrenal carcinoma may be responsible for a specific profile of the serum concentrations of mineralo-steroids, compatible with a blockade of the last step of the aldosterone synthesis. The exploration of primary hyperaldosteronism requires biological and imaging techniques. Tabarin et al summarize the main biological parameters and tests available for the diagnosis of this condition and delineate the indications of imaging techniques, associated to hormonal tests to distinguish between adenoma and bilateral adrenal hyperplasia. (author). 104 refs

  7. Primary Anorectal Melanoma

    Directory of Open Access Journals (Sweden)

    Maliha Khan

    2014-03-01

    Full Text Available Primary malignant melanoma of the anus and rectum is a rare and aggressive neoplasm that tends to invade locally and metastasize early in the course of the disease. It is often misdiagnosed as hemorrhoids or as one of the other benign anorectal conditions and is thus linked to an overall poor prognosis and a 5-year survival rate of less than 20%. Optimal treatment is still controversial, and current evidence does not show any preferential survival benefit from abdominoperineal resection over wide local excision. Chemotherapy or radiotherapy may be used for advanced disease. We report a 71-year-old female presenting with painful bowel movements and blood in stools. She was eventually found to have a mass arising from the anorectal junction with regional lymph node involvement. The patient underwent an abdominoperineal resection and is currently scheduled for chemotherapy.

  8. Primary conjunctival amyloidosis

    Directory of Open Access Journals (Sweden)

    Chandana Chakraborti

    2014-01-01

    Full Text Available A 19-year-old previously healthy male presented with a 4 year history of painless drooping of right upper eyelid.On eversion of the right upper eyelid, a yellowish pink mass was seen in the tarsal region. Rest of the ocular examination was normal in both the eyes. Initial biopsy showed chronic inflammation. Subsequently, the entire mass was excised and histopathological examination showed the presence of amyloid in the subconjunctival stroma. At 3 months follow-up, similar lesion was detected in the right lower, left upper, and lower lid, which were treated with cryotherapy, with partial resolution. Patient has been followed up for more than 2 years without any complaints. To our knowledge, this is the first case report of an isolated primary conjunctival amyloidosis with involvement of both the upper and lower palpebral conjunctiva of either eye. It was treated successfully by excision and cryotherapy.

  9. Prostaglandins and primary dysmenorrhea

    International Nuclear Information System (INIS)

    Seifert, B.; Liedtke, M.P.; Kempf, H.J.; Richter, H.; Alexander, H.; Herter, U.

    1978-01-01

    In 100 patients a total of 171 PG determinations in the menstrual blood was performed under standardized conditions. The primary PGE 1 and PGFsub(2α) were determined by RIA. The evaluation of the analysis of the sexual hormones resulted in a group with a biphasic cycle without dysmenorrhea and a group with a biphasic cycle with dysmenorrhea. Highly significant differences (p < 0.01) were found in the PGFsub(2α) concentration in menstrual blood between a group of healthy women and one of patients with dysmenorrhea. In dysmenorrhea the ratio of the PGs investigated is shifted in favor of PGFsub(2α). Indomethacin can decrease the PGFsub(2α) levels in dysmenorrhea up to 15% (p < 0.01). All treated patients reported that their conditions had improved. Five out of seven women were completely without any complaints. (author)

  10. PRIMARY SCHOOL TEACHER

    CERN Multimedia

    Madeleine Dittus

    2002-01-01

    For the beginning of the school year 2002/2003, the A.P.E.G. has an opening for a primary school teacher in the German national language program. The position requires one afternoon of teaching (13:30 till 16:30) every Tuesday at the Collège in Prévessin. The candidate should be a native speaker of German and have some knowledge of French. If you are interested, please send your CV, a copy of your diploma, and a short letter of motivation, until March 10th, to the following address. Madeleine Dittus - Présidente A.P.E.G. 5, La vie Destraz 01630 St. Genis-Pouilly - France

  11. Primary Fallopian Tube Carcinoma

    Directory of Open Access Journals (Sweden)

    Prasad K Shetty

    2011-01-01

    Full Text Available Primary Fallopian Tube Carcinoma (PFTC is rare and accounts for about 0.3% of all gynecologic cancers. Less than 1500 cases have been reported in the literature. It arises in postmenopausal women and typically presents with abdominal pelvic pain, vaginal bleeding and watery discharge. However, a correct diagnosis is rarely achieved preoperative, and in many cases, the diagnosis is made after incidental surgery for unrelated conditions commonly being ovarian carcinoma . Compared with ovarian carcinoma, PFTC more often presents at early stages, but it has a worse prognosis. PFTC is usually managed in the same manner as ovarian cancer. We report a case of Left PFTC that presented as Left ovarian mass, and we briefly review the literature.

  12. Primary aldosteronism. Clinical management

    International Nuclear Information System (INIS)

    Grant, C.S.; Carpenter, P.; van Heerden, J.A.; Hamberger, B.

    1984-01-01

    We retrospectively reviewed the clinical features, methods of diagnosis and localization, and results of treatment in 105 patients with primary aldosteronism seen between 1969 and 1981. Coincident with the use of computed tomography (CT), 131 I-6-beta-iodomethyl norcholesterol scans (NP-59), and postural response studies, the study group was temporally divided into pre-1976 and post-1976 groups, and subdivided into groups with aldosterone-producing adenoma (APA) and idiopathic hyperaldosteronism (IHA) due to bilateral adrenal hyperplasia. Our results indicate that aldosterone postural response studies and CT differentiate and localize APA and IHA reliably. Adrenalectomy is a safe and effective treatment for APA, whereas medical treatment alone is preferable for IHA

  13. Primary Identity in Literature

    DEFF Research Database (Denmark)

    Graham, Brian Russell

    In our times, literary criticism, as well as larger political and cultural developments, is characterized by identity politics, meaning that our discourses are structured around the notion of different socially identifiable populations in society. In relation to literature, this results in our...... viewing the characters in literature in terms of these political identities. Literature is consequently discussed in relation to political causes. Literary criticism is animated by the same causes, and is viewed as having a direct intervention in society in relation to them. In this paper, I will discuss......, in relation to Frye’s works, the idea that the primary identities of characters in literature were and, to a considerable extent, continue to be those of family-member identities. As such, literature should not be appropriated to a political context too readily. Whereas viewing characters in terms of...

  14. [Primary care in Belgium].

    Science.gov (United States)

    Sánchez-Sagrado, T

    2017-09-01

    Belgium is an attractive country to work in, not just for doctors but for all Spanish workers, due to it having the headquarters of European Union. The health job allure is double; on the one hand, the opportunity to find a decent job, and on the other, because it is possible to develop their professional abilities with patients of the same nationality in a health system with a different way of working. The Belgium health care system is based on security social models. Health care is financed by the government, social security contributions, and voluntary private health insurance. Primary care in Belgium is very different to that in Spain. Citizens may freely choose their doctor (general practitioner or specialist) increasing the lack of coordination between primary and specialized care. This leads to serious patient safety problems and loss of efficiency within the system. Belgium is a European country with room to improve preventive coverage. General practitioners are self-employed professionals with free choice of setting, and their salary is linked to their professional activity. Ambulatory care is subjected to co-payment, and this fact leads to great inequities on access to care. The statistics say that there is universal coverage but, in 2010, 14% of the population did not seek medical contact due to economic problems. It takes 3 years to become a General Practitioner and continuing medical education is compulsory to be revalidated. In general, Belgian and Spaniards living and working in Belgium are happy with the functioning of the health care system. However, as doctors, we should be aware that it is a health care system in which access is constrained for some people, and preventive coverage could be improved. Copyright © 2016 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Primary Teacher Education in Malaysia

    Science.gov (United States)

    Ching, Chin Phoi; Yee, Chin Peng

    2012-01-01

    In Malaysia the training of primary school teachers is solely carried out by teacher training institutes which offer the Bachelor of Teaching with Honors (Primary education) program and was first launched in 2007. This program prepares primary school teachers specializing in various subjects or major and is carried out in 27 teacher training…

  16. Indoor air pollution and cognitive function among older Mexican adults.

    Science.gov (United States)

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Autologous Blood Pleurodesis In Patients With Persistent Air Leaks

    Directory of Open Access Journals (Sweden)

    Agkajanzadeh M

    2003-10-01

    Full Text Available Persistent air leaks occur after Spontaneous pneumothorax both primary and secondary, and after lungs trauma and lung surgeries are sever problems encountered chest surgeons with. Persistent air leak causes longer patients hospitalization."nMaterials and Methods: We used autologous blood pleurodesis in patients with persistent air leak for 30patients with more than 8 days air leaks, during a three years period 1377-1380 (1999-2002."nResults: The patients had 19 years up to 70 years old. Eight patients had thoracotomy and lobectomy and /or segmentectomies 6 with primary pneumothorax, 10 with secondary pneumothorax, and four with penetrated or blunt thoracic traumas. Blood was obtained from femoral or brachial veins and 70-150 mis. Injected in chest tubes. Chest bottle was first lied 80cm higher than body levels. After 24 hours repositioned in normal levels, and patients were supervised. Via chest tube we injected blood 70-100ml.for young patients, and 100-150 ml for older patients into intra pleural space. There were no clamped chest tubes. There were no pain, respiratory distress, fever, or cough in pleurodesized patients. The only patient's complaint was local pain in femoral vein or brachial vein because blood sampling and blood obtaining, although there was no local visible complication as hematoma or bleeding. After 48 hours in 24 patients air leak ceased. In six patients because persistent air leak autologous blood pleurodesis repeated, two patients after 48hours"nair leak ceased, remaining four patients underwent for thoracotomies, success rate"nwas 86.6%."nConclusion: According above success rate we suggest autologous blood pleurodesis in patients with persistent air leak is a reliable, effective, and no complicated procedure for persistent air leaks.

  18. Standards and laws for indoor air quality in Russia

    International Nuclear Information System (INIS)

    Bitkolov, N.; Musijchuk, Y.

    1997-01-01

    The air quality of indoor air in Russia, including the special problems of air quality with regard to radioactive contamination, is determined by a number of statutes, standards and regulations. All these are based on the biological principles that the maximum allowable concentrations of pollutants (MAC) and the prescribed radioactive safety dose limits should not be exceeded. The standards cover the air in the working zones of all ministries and departments, and are for trade unions, public and cooperative organisations and foundations. The basic Russian law for air quality is 'The Law on Environmental Nature Protection' (19.2.1991) which assures the right to health protection from adverse environmental effects. In the field of radioactive safety 'The Federal Law on Radioactive Safety' (9.1.1996) is the primary law and in accordance with it, every citizen living in Russia has the right to protection for the present and future generations from health-related deleterious effects of atomic radiation. The laws on air quality are part of the Russian Federation legal system and are secured in the Constitution. The air quality must be controlled by the Goscomgidromet and the Sunepidnadzor of Russia. In compliance with these laws everybody has the right to a favourable environment and the duty to protect, preserve and maintain it. The air environment is unique and common to all, thus economic cooperation dictates that a dedicated approach to air quality and air quality regulations would be the most appropriate way to preserve it. It appears judicious to join forces in the name of European ecological safety. To do this, it is necessary to combine the national means and secure. (author) 4 figs

  19. Air pollution control in India

    International Nuclear Information System (INIS)

    Jain, S.K.

    1995-01-01

    Prior to rapid spurt in industrialization in India, people were used to inhale pure air containing about 78% nitrogen, 21% oxygen and some carbon dioxide. But afterwards this composition of pure air was disturbed as a result of increased economic activities. Air, now a days also contains sulphur dioxide, carbon monoxide, nitrogen oxides etc., etc. which are extremely harmful for human health. Virulence of air pollution was realised in late eighties after Bhopal Gas Tragedy (BGT) and an effective air quality management started taking shape in India afterwards. The basic components of air quality management are legislation and regulations, emission inventory, air quality standards and monitoring, air dispersion models and installation of pollution control equipment which are being discussed in this paper. (author). 15 refs., 5 tabs

  20. Air Markets Program Data (AMPD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Markets Program Data tool allows users to search EPA data to answer scientific, general, policy, and regulatory questions about industry emissions. Air...

  1. Air Compliance Complaint Database (ACCD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — THIS DATA ASSET NO LONGER ACTIVE: This is metadata documentation for the Region 7 Air Compliance Complaint Database (ACCD) which logs all air pollution complaints...

  2. Air Emissions Factors and Quantification

    Science.gov (United States)

    Emissions factors are used in developing air emissions inventories for air quality management decisions and in developing emissions control strategies. This area provides technical information on and support for the use of emissions factors.

  3. Development of the air module for the work information management system. Environmental subsystem (WIMS-ES). Master's thesis

    Energy Technology Data Exchange (ETDEWEB)

    Cantwell, R.A.; Davis, J.S.

    1992-09-01

    The primary objective of this research was to develop the air module for the Work Information Management System Environmental Subsystem (WIMSES). The air module will provide Air Force environmental managers with a management information system (MIS) to control the growing amount of air pollution data required to stay in compliance with the newly amended Clean Air Act. To develop the air module, the Air Force's air pollution management requirements were researched first. These requirements were then compared to the capabilities of existing air pollution MISs used in the Department of Defense, the Environmental Protection Agency, and in commercial industry. The research led to a draft air nodule that tracks a base's source inventory and associated permit, control equipment, and emission information. Each base's data will be fully accessible to headquarters personnel through the fully networked WIMS-ES. The draft air nodule was validated through an Air Staff review, an Air Force review, and finally, a workshop with Air Force air pollution experts. The finalized air module has been forwarded to the WIMS-ES programmers and will become the Air Force-wide air pollution MIS in early 1993.... Air pollution, Environmental management, Data management, Data bases, Management information systems, Information systems.

  4. Acceptance test report for 241-AW process air system

    International Nuclear Information System (INIS)

    Kostelnik, A.J.

    1994-01-01

    The acceptance test procedure (ATP) for the compressed air system at building 241-AW-273 was completed on March 11, 1993. The system was upgraded to provide a reliable source of compressed air to the tank farm. The upgrade included the demolition of the existing air compressor and associated piping, as well as the installation of a new air compressor with a closed loop cooling system. A compressed air cross-tie was added to allow the process air compressor to function as a back-up to the existing instrument air compressor. The purpose of the ATP was to achieve three primary objectives: verify system upgrade in accordance with the design media; provide functional test of system components and controls; and prepare the system for the Operational Test. The ATP was successfully completed with thirteen exceptions, which were resolved prior to completing the acceptance test. The repaired exceptions had no impact to safety or the environment and are briefly summarized. Testing ensured that the system was installed per design, that its components function as required and that it is ready for operational testing and subsequent turnover to operations

  5. Range-extending Zinc-air battery for electric vehicle

    Directory of Open Access Journals (Sweden)

    Steven B. Sherman

    2018-01-01

    Full Text Available A vehicle model is used to evaluate a novel powertrain that is comprised of a dual energy storage system (Dual ESS. The system includes two battery packs with different chemistries and the necessary electronic controls to facilitate their coordination and optimization. Here, a lithium-ion battery pack is used as the primary pack and a Zinc-air battery as the secondary or range-extending pack. Zinc-air batteries are usually considered unsuitable for use in vehicles due to their poor cycle life, but the model demonstrates the feasibility of this technology with an appropriate control strategy, with limited cycling of the range extender pack. The battery pack sizes and the battery control strategy are configured to optimize range, cost and longevity. In simulation the vehicle performance compares favourably to a similar vehicle with a single energy storage system (Single ESS powertrain, travelling up to 75 km further under test conditions. The simulation demonstrates that the Zinc-air battery pack need only cycle 100 times to enjoy a ten-year lifespan. The Zinc-air battery model is based on leading Zinc-air battery research from literature, with some assumptions regarding achievable improvements. Having such a model clarifies the performance requirements of Zinc-air cells and improves the research community's ability to set performance targets for Zinc-air cells.

  6. The air of Europe: where are we going?

    Directory of Open Access Journals (Sweden)

    Isabella Annesi-Maesano

    2017-12-01

    Full Text Available Air pollution constitutes one of the main threats to public health in Europe. Significant impacts on the health of Europeans in terms of morbidity and mortality have been observed, even in cases of low exposure and where pollutant levels are within limits set by the European Union (EU. The respiratory system is a primary target of the harmful effects of key air pollutants. Emissions of many air pollutants have decreased substantially over the past decades in Europe, resulting in diminished concentrations and improved air quality. However, in several European cities concentrations still exceed EU reference values and, more often, the stricter World Health Organization air quality guidelines for all regulated air pollutants (particles with 50% cut-off aerodynamic diameters of 10 and 2.5 µm, nitrogen dioxide (NO2, benzo[a]pyrene and ozone (O3 except sulfur dioxide. In addition, current trends indicate that in the absence of substantial changes, particulate matter, NO2 and O3 will still exceed limits in 2020. Additional efforts must be made to comply with current standards and guidelines. These should include a more accurate and detailed monitoring of air pollutants, reduction of emissions and individual behaviour changes.

  7. Iron-Air Rechargeable Battery

    Science.gov (United States)

    Narayan, Sri R. (Inventor); Prakash, G.K. Surya (Inventor); Kindler, Andrew (Inventor)

    2014-01-01

    Embodiments include an iron-air rechargeable battery having a composite electrode including an iron electrode and a hydrogen electrode integrated therewith. An air electrode is spaced from the iron electrode and an electrolyte is provided in contact with the air electrode and the iron electrodes. Various additives and catalysts are disclosed with respect to the iron electrode, air electrode, and electrolyte for increasing battery efficiency and cycle life.

  8. Human preference for air movement

    DEFF Research Database (Denmark)

    Toftum, Jørn; Melikov, Arsen Krikor; Tynel, A.

    2002-01-01

    Human preference for air movement was studied at slightly cool, neutral, and slightly warm overall thermal sensations and at temperatures ranging from 18 deg.C to 28 deg.C. Air movement preference depended on both thermal sensation and temperature, but large inter-individual differences existed...... between subjects. Preference for less air movement was linearly correlated with draught discomfort, but the percentage of subjects who felt draught was lower than the percentage who preferred less air movement....

  9. Air Separation Using Hollow Fiber Membranes

    Science.gov (United States)

    Huang, Stephen E.

    2004-01-01

    The NASA Glenn Research Center in partnership with the Ohio Aerospace Institute provides internship programs for high school and college students in the areas of science, engineering, professional administrative, and other technical areas. During the summer of 2004, I worked with Dr. Clarence T. Chang at NASA Glenn Research Center s combustion branch on air separation using hollow fiber membrane technology. . In light of the accident of Trans World Airline s flight 800, FAA has mandated that a suitable solution be created to prevent the ignition of fuel tanks in aircrafts. In order for any type of fuel to ignite, three important things are needed: fuel vapor, oxygen, and an energy source. Two different ways to make fuel tanks less likely to ignite are reformulating the fuel to obtain a lower vapor pressure for the fuel and or using an On Board Inert Gas Generating System (OBIGGS) to inert the Central Wing Tank. goal is to accomplish the mission, which means that the Air Separation Module (ASM) tends to be bulky and heavy. The primary goal for commercial aviation companies is to transport as much as they can with the least amount of cost and fuel per person, therefore the ASM must be compact and light as possible. The plan is to take bleed air from the aircraft s engines to pass air through a filter first to remove particulates and then pass the air through the ASM containing hollow fiber membranes. In the lab, there will be a heating element provided to simulate the temperature of the bleed air that will be entering the ASM and analysis of the separated air will be analyzed by a Gas Chromatograph/Mass Spectrometer (GC/MS). The GUMS will separate the different compounds in the exit streams of the ASM and provide information on the performance of hollow fiber membranes. Hopefully I can develop ways to improve efficiency of the ASM. different types of jet fuel were analyzed and data was well represented on SAE Paper 982485. Data consisted of the concentrations of over

  10. Air Pollution in Europe

    International Nuclear Information System (INIS)

    1997-09-01

    In spite of improvements relative to air pollution, there is still much to do. more than thirty millions of European people are exposed to sulfur dioxide concentrations superior to guide values for health fixed by European Union, 20% of ecosystems in Europe are above the critical charges in the area of acidification and 33% concern eutrophication. Relative to the carbon dioxide, it is not sure that European Union realize the objective to stabilize the emissions for the year 2000 at the level of the year 1990, because of the increasing of automobile traffic and the energy consumption. Four subjects are presented: the climatic change, acidification and eutrophication, tropospheric ozone and air quality. (N.C.)

  11. Air pollution and lichens

    Energy Technology Data Exchange (ETDEWEB)

    Ferry, B W; Baddeley, M S; Hawksworth, D L [eds.

    1973-01-01

    This volume reflects the particular concern of many biologists for the effects of air pollution and illustrates the special values of lichens as plants suitable for such studies. It brings together contributions from many experts in this field and includes much previously unpublished data, as well as up-to-date review chapters. Emphasis is placed on the logical progression from field observational studies to critical laboratory investigations aimed at elucidating the modes of action of various air pollutants on the living tissues of lichens. The action of such pollutants on vascular plants is also discussed. It is the editors' intention that the book be both a reference volume and an encouragement for further wor

  12. Lidar: air pollution applications

    International Nuclear Information System (INIS)

    Collis, R.T.H.

    1977-01-01

    This introduction to the use of lidar in air pollution applications is mainly concerned with its capability to detect and monitor atmospheric particulates by elastic backscattering. Even when quite imperceptible to the eye, such particulates may be detected at ranges of several kilometers even by lidars of modest performance. This capability is valuable in connection with air pollution in the following ways: by mapping and tracking inhomogeneities in particulate concentration, atmospheric structure and motion may be monitored; measurements of the optical properties of the atmosphere provide an indication of turbidity or of particulate number or mass concentrations; and the capability of obtaining at a single point return signals from remote atmospheric volumes makes it possible to make range-resolved measurements of gaseous concentration along the path by using the resonant absorption of energy of appropriate wavelengths

  13. Air transport system

    CERN Document Server

    Schmitt, Dieter

    2016-01-01

    The book addresses all major aspects to be considered for the design and operation of aircrafts within the entire transportation chain. It provides the basic information about the legal environment, which defines the basic requirements for aircraft design and aircraft operation. The interactions between  airport, air traffic management and the airlines are described. The market forecast methods and the aircraft development process are explained to understand the very complex and risky business of an aircraft manufacturer. The principles of flight physics as basis for aircraft design are presented and linked to the operational and legal aspects of air transport including all environmental impacts. The book is written for graduate students as well as for engineers and experts, who are working in aerospace industry, at airports or in the domain of transport and logistics.

  14. Hot air balloon engine

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, Ian [Solartran Pty Ltd, 12 Lentara Street, Kenmore, Brisbane 4069 (Australia)

    2009-04-15

    This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines. (author)

  15. Aeromicrobiology/air quality

    Science.gov (United States)

    Andersen, Gary L.; Frisch, A.S.; Kellogg, Christina A.; Levetin, E.; Lighthart, Bruce; Paterno, D.

    2009-01-01

    The most prevalent microorganisms, viruses, bacteria, and fungi, are introduced into the atmosphere from many anthropogenic sources such as agricultural, industrial and urban activities, termed microbial air pollution (MAP), and natural sources. These include soil, vegetation, and ocean surfaces that have been disturbed by atmospheric turbulence. The airborne concentrations range from nil to great numbers and change as functions of time of day, season, location, and upwind sources. While airborne, they may settle out immediately or be transported great distances. Further, most viable airborne cells can be rendered nonviable due to temperature effects, dehydration or rehydration, UV radiation, and/or air pollution effects. Mathematical microbial survival models that simulate these effects have been developed.

  16. Aqueous lithium air batteries

    Science.gov (United States)

    Visco, Steven J.; Nimon, Yevgeniy S.; De Jonghe, Lutgard C.; Petrov, Alexei; Goncharenko, Nikolay

    2017-05-23

    Aqueous Li/Air secondary battery cells are configurable to achieve high energy density and prolonged cycle life. The cells include a protected a lithium metal or alloy anode and an aqueous catholyte in a cathode compartment. The aqueous catholyte comprises an evaporative-loss resistant and/or polyprotic active compound or active agent that partakes in the discharge reaction and effectuates cathode capacity for discharge in the acidic region. This leads to improved performance including one or more of increased specific energy, improved stability on open circuit, and prolonged cycle life, as well as various methods, including a method of operating an aqueous Li/Air cell to simultaneously achieve improved energy density and prolonged cycle life.

  17. Air Pollution, Causes and Cures.

    Science.gov (United States)

    Manufacturing Chemists Association, Washington, DC.

    This commentary on sources of air pollution and air purification treatments is accompanied by graphic illustrations. Sources of carbon monoxide, sulfur oxides, nitrogen oxides, and hydrocarbons found in the air are discussed. Methods of removing these pollutants at their source are presented with cut-away diagrams of the facilities and technical…

  18. Air Pollution in Museum Buildings

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, Morten

    2017-01-01

    This paper reviews the main air pollutants relevant for preservation of cultural heritage objects. Air pollutants may originate from outdoor or indoor sources. Indoor sources include the emission of corrosive vapors from construction materials used for museum display settings. Air pollution may...

  19. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  20. Biologically resistant contaminants, primary treatment with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Echegaray, Diego F. [White Martins Gases Industriais do Nordeste S.A., Salvador, BA (Brazil); Olivieri, Nadja F. [White Martins Gases Industriais S.A., Cordovil, RJ (Brazil)

    1993-12-31

    Organic effluent oxidation tests were conducted in petrochemical companies, in Camacari Petrochemical Complex (Northeast Brazil), to reduce treatment costs and improve the primary treatment efficiency in each industrial process. Ozone achieved 99.96 percent benzene reduction and 100 percent ethyl benzene and toluene reduction. Process efficiency is strongly dependent on the wastewater chemical composition and concentration. For this reason it is necessary to run pilot trials for each specific case. Ozone was obtained feeding commercial oxygen through a corona discharge generator and dissolved in the effluent with a bubble column. Commercial oxygen was used instead of air to increase 250 percent the ozone production, using the same ozone generator. (author). 4 figs., 2 tabs.