WorldWideScience

Sample records for previously open magnetic

  1. Structure and magnetic field of periodic permanent magnetic focusing system with open magnetic rings

    International Nuclear Information System (INIS)

    Peng Long; Li Lezhong; Yang Dingyu; Zhu Xinghua; Li Yuanxun

    2011-01-01

    The magnetic field along the central axis for an axially magnetized permanent magnetic ring was investigated by analytical and finite element methods. For open magnetic rings, both calculated and measured results show that the existence of the radial magnetic field creates a remarkable cosine distribution field along the central axis. A new structure of periodic permanent magnet focusing system with open magnetic rings is proposed. The structure provides a satisfactory magnetic field with a stable peak value of 120 mT for a traveling wave tube system. - Research highlights: → For open magnetic rings, both calculated and measured results show that the existence of the radial magnetic field creates a remarkable cosine distribution field along the central axis. → A new structure of periodic permanent magnet (PPM) focusing system with open magnetic rings is proposed. → The new PPM focusing system with open magnetic rings meets the requirements for TWT system.

  2. Open magnetic fields and the solar cycle. Pt. 1

    International Nuclear Information System (INIS)

    Levine, R.H.

    1982-01-01

    Models of open magnetic structures on the Sun are presented for periods near solar minimum (CR 1626-1634) and near solar maximum (CR 1668-1678). Together with previous models of open magnetic structures during the declining phase (CR 1601-1611) these calculations provide clues to the relations between open structures, coronal holes, and active regions at different times of the solar cycle. Near solar minimum the close relation between active regions and open structures does not exist. It is suggested that near solar minimum the systematic emergence of new flux with the proper polarity imbalance to maintain open magnetic structures may occur primarily at very small spatial scales. Near solar maximum the role of active regions in maintaining open structures and coronal holes is strong, with large active regions emerging in the proper location and orientation to maintain open structures longer than typical active region lifetimes. Although the use of He I 10830 A spectroheliograms as a coronal hole indicator is shown to be subject to significant ambiguity, the agreement between calculated open structures and coronal holes determined from He I 10830 A spectroheliograms is very good. The rotation properties of calculated open structures near solar maximum strongly suggest two classes of features: one that rotates differentially similar to sunspots and active regions and a separate class that rotates more rigidly, as was the case for single large coronal holes during Skylab. (orig.)

  3. Measurements of EUV coronal holes and open magnetic flux

    International Nuclear Information System (INIS)

    Lowder, C.; Qiu, J.; Leamon, R.; Liu, Y.

    2014-01-01

    Coronal holes are regions on the Sun's surface that map the footprints of open magnetic field lines. We have developed an automated routine to detect and track boundaries of long-lived coronal holes using full-disk extreme-ultraviolet (EUV) images obtained by SOHO/EIT, SDO/AIA, and STEREO/EUVI. We measure coronal hole areas and magnetic flux in these holes, and compare the measurements with calculations by the potential field source surface (PFSS) model. It is shown that, from 1996 through 2010, the total area of coronal holes measured with EIT images varies between 5% and 17% of the total solar surface area, and the total unsigned open flux varies between (2-5)× 10 22 Mx. The solar cycle dependence of these measurements is similar to the PFSS results, but the model yields larger hole areas and greater open flux than observed by EIT. The AIA/EUVI measurements from 2010-2013 show coronal hole area coverage of 5%-10% of the total surface area, with significant contribution from low latitudes, which is under-represented by EIT. AIA/EUVI have measured much enhanced open magnetic flux in the range of (2-4)× 10 22 Mx, which is about twice the flux measured by EIT, and matches with the PFSS calculated open flux, with discrepancies in the location and strength of coronal holes. A detailed comparison between the three measurements (by EIT, AIA-EUVI, and PFSS) indicates that coronal holes in low latitudes contribute significantly to the total open magnetic flux. These low-latitude coronal holes are not well measured with either the He I 10830 line in previous studies, or EIT EUV images; neither are they well captured by the static PFSS model. The enhanced observations from AIA/EUVI allow a more accurate measure of these low-latitude coronal holes and their contribution to open magnetic flux.

  4. Open magnetic structures on the sun

    International Nuclear Information System (INIS)

    Levine, R.H.; Altschuler, M.D.; Harvey, J.W.; Jackson, B.V.

    1977-01-01

    High-resolution harmonic analysis of the solar magnetic field has been used successfully to calculate the geometry of open magnetic field lines in the solar corona. Comparison of the loci of open field line footpoints with solar X-ray photographs shows that all of the coronal holes during two solar rotations are successfully represented, including details of their evolution. Some open magnetic configurations derived in the calculations precede by up to one solar rotation the manifestation of coincident dark areas on the X-ray photographs. The only other areas that contribute open field lines to the corona are separations between active-region loop systems. By varying the radius at which field lines are forced to be open in the calculation, it is possible to more closely reproduce the surface configuration of particular coronal holes. Comparison of the size of X-ray holes with the fraction of the solar surface covered by open field lines leads to the conclusion that a significant part of the area of coronal holes must contain closed magnetic fields. Comparison of open field lines which lie in the equatorial plane of the Sun with solar wind data indicates that eventual high-speed solar wind streams are associated with those parts of open magnetic structures that diverge the least. Several important questions raised by this study are under investigation using data for the entire Skylab period

  5. Measurements of EUV coronal holes and open magnetic flux

    Energy Technology Data Exchange (ETDEWEB)

    Lowder, C.; Qiu, J.; Leamon, R. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States); Liu, Y., E-mail: clowder@solar.physics.montana.edu [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 (United States)

    2014-03-10

    Coronal holes are regions on the Sun's surface that map the footprints of open magnetic field lines. We have developed an automated routine to detect and track boundaries of long-lived coronal holes using full-disk extreme-ultraviolet (EUV) images obtained by SOHO/EIT, SDO/AIA, and STEREO/EUVI. We measure coronal hole areas and magnetic flux in these holes, and compare the measurements with calculations by the potential field source surface (PFSS) model. It is shown that, from 1996 through 2010, the total area of coronal holes measured with EIT images varies between 5% and 17% of the total solar surface area, and the total unsigned open flux varies between (2-5)× 10{sup 22} Mx. The solar cycle dependence of these measurements is similar to the PFSS results, but the model yields larger hole areas and greater open flux than observed by EIT. The AIA/EUVI measurements from 2010-2013 show coronal hole area coverage of 5%-10% of the total surface area, with significant contribution from low latitudes, which is under-represented by EIT. AIA/EUVI have measured much enhanced open magnetic flux in the range of (2-4)× 10{sup 22} Mx, which is about twice the flux measured by EIT, and matches with the PFSS calculated open flux, with discrepancies in the location and strength of coronal holes. A detailed comparison between the three measurements (by EIT, AIA-EUVI, and PFSS) indicates that coronal holes in low latitudes contribute significantly to the total open magnetic flux. These low-latitude coronal holes are not well measured with either the He I 10830 line in previous studies, or EIT EUV images; neither are they well captured by the static PFSS model. The enhanced observations from AIA/EUVI allow a more accurate measure of these low-latitude coronal holes and their contribution to open magnetic flux.

  6. Alpha Channeling in Open-System Magnetic Devices

    International Nuclear Information System (INIS)

    Fisch, Nathaniel

    2016-01-01

    The Grant DE-SC0000736, Alpha Channeling in Open-System Magnetic Devices, is a continuation of the Grant DE-FG02-06ER54851, Alpha Channeling in Mirror Machines. In publications funded by DE-SC0000736, the grant DE-FG02-06ER54851 was actually credited. The key results obtained under Grant DE-SC0000736, Alpha Channeling in Open-System Magnetic Devices, appear in a series of publications. The earlier effort under DE-FG02- 06ER54851 was the subject of a previous Final Report. The theme of this later effort has been unusual confinement effects, or de-confinement effects, in open-field magnetic confinement devices. First, the possibilities in losing axisymmetry were explored. Then a number of issues in rotating plasma were addressed. Most importantly, a spinoff application to plasma separations was recognized, which also resulted in a provisional patent application. (That provisional patent application, however, was not pursued further.) Alpha channeling entails injecting waves into magnetically confined plasma to release energy from one particular ion while ejecting that ion. The ejection of the ion is actually a concomitant effect in releasing energy from the ion to the wave. In rotating plasma, there is the opportunity to store the energy in a radial electric field rather than in waves. In other words, the ejected alpha particle loses its energy to the radial potential, which in turn produces plasma rotation. This is a very useful effect, since producing radial electric fields by other means are technologically more difficult. In fact, one can heat ions, and then eject them, to produce the desired radial field. In each case, there is a separation effect of different ions, which generalizes the original alpha-channeling concept of separating alpha ash from hydrogen. In a further generalization of the separation concept, a double-well filter represents a new way to produce high-throughput separations of ions, potentially useful for nuclear waste remediation.

  7. Open-ended magnetic confinement systems for fusion

    International Nuclear Information System (INIS)

    Post, R.F.; Ryutov, D.D.

    1995-05-01

    Magnetic confinement systems that use externally generated magnetic fields can be divided topologically into two classes: ''closed'' and 'open''. The tokamak, the stellarator, and the reversed-field-pinch approaches are representatives of the first category, while mirror-based systems and their variants are of the second category. While the recent thrust of magnetic fusion research, with its emphasis on the tokamak, has been concentrated on closed geometry, there are significant reasons for the continued pursuit of research into open-ended systems. The paper discusses these reasons, reviews the history and the present status of open-ended systems, and suggests some future directions for the research

  8. The evolution of magnetic structures due to open-quote open-quote magnetosonic streaming close-quote close-quote

    International Nuclear Information System (INIS)

    Ryutova, M.P.; Kaisig, M.; Tajima, T.

    1996-01-01

    The Faraday effect in gasdynamics called acoustic streaming and its accompanying nonlinear phenomena have analogies in plasma magnetohydrodynamics. A natural place where these effects may occur is the solar atmosphere with its strongly inhomogeneous magnetic fields concentrated in random magnetic flux tubes. Unlike acoustic streaming in the usual gasdynamics, nonlinear phenomena consisting in the generation of plasma flows by an oscillating magnetic flux tube, open-quote open-quote magnetosonic streaming close-quote close-quote (Ryutova 1986), is accompanied by a current drive and results in a specific evolution of magnetic structures: depending on the physical parameters of the medium a single magnetic flux tube may be either split into thinner flux tubes or dissolved diffusively into the ambient plasma. The effect of the open-quote open-quote magnetosonic streaming,close-quote close-quote on one hand, is an obvious candidate for the generation of mass flows at magnetic flux tubes sites, and on the other hand, it plays an essential role in the evolution of magnetic structures and ultimately may determine their lifetime. The theory of magnetosonic streaming is general and can be applied to other astrophysical objects that maintain oscillatory motions and contain structured magnetic fields or magnetic domains. We review analytical results and describe the origin of the magnetosonic streaming in magnetic flux tubes due to their interaction with acoustic waves. We study numerically the regime of the open-quote open-quote magnetosonic streaming close-quote close-quote corresponding to splitting of a magnetic flux tube. Our computer simulation supports and extends the analytical result. copyright 1996 The American Astronomical Society

  9. Anterior open bite treatment with magnets.

    Science.gov (United States)

    Kiliaridis, S; Egermark, I; Thilander, B

    1990-11-01

    The aim of this study was to examine the effects of repelling magnets on the treatment of anterior open bite and compare them with the effects of acrylic posterior bite-blocks. Twenty patients, aged 9-16 years with skeletal anterior open bite, were randomly divided into two groups. In one group the patients wore posterior repelling magnet splints and in the other they wore acrylic posterior bite-blocks of the same thickness as the magnet splints. The patients were instructed to use their appliance as much as possible (the minimum accepted being 18 hours daily) during a 6-month period. Dental casts, intra-oral photos, and lateral cephalograms were taken before and after treatment, and the patients were also examined regularly to identify the development of any craniomandibular disorders. In the first group, the dental and skeletal vertical relation responded quickly to the magnet treatment. The open bite was generally closed in just under 4 months, especially in patients in early mixed dentition. Spacing in the labial segments decreased in some cases, while slight crowding was induced in others. Transverse problems, i.e. unilateral cross-bite, sometimes followed by scissor-bite on the opposite side, was observed in those patients who were in the early mixed dentition and had used the magnets intensively. The patients who wore acrylic posterior bite-blocks also showed improvement in the dental and skeletal vertical relationships, especially during the first months. This was followed by a 'plateau' period. No transverse problems were found in these patients.

  10. Tessellated permanent magnet circuits for flow-through, open gradient separations of weakly magnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Lee R. [Department of Biomedical Engineering, Cleveland Clinic, 9500 Euclid Ave., Cleveland OH 44195 (United States); Williams, P. Stephen [Cambrian Technologies, Inc., Cleveland, OH (United States); Chalmers, Jeffrey J. [William G. Lowrie Department of Chemical and Biomedical Engineering, The Ohio State University, Columbus 151 W. Woodruff Avenue, OH 43210 (United States); Zborowski, Maciej, E-mail: zborowm@ccf.org [Department of Biomedical Engineering, Cleveland Clinic, 9500 Euclid Ave., Cleveland OH 44195 (United States)

    2017-04-01

    Emerging microfluidic-based cell assays favor label-free red blood cell (RBC) depletion. Magnetic separation of RBC is possible because of the paramagnetism of deoxygenated hemoglobin but the process is slow for open-gradient field configurations. In order to increase the throughput, periodic arrangements of the unit magnets were considered, consisting of commercially available Nd-Fe-B permanent magnets and soft steel flux return pieces. The magnet design is uniquely suitable for multiplexing by magnet tessellation, here meaning the tiling of the magnet assembly cross-sectional plane by periodic repetition of the magnet and the flow channel shapes. The periodic pattern of magnet magnetizations allows a reduction of the magnetic material per channel with minimal distortion of the field cylindrical symmetry inside the magnet apertures. A number of such magnet patterns are investigated for separator performance, size and economy with the goal of designing an open-gradient magnetic separator capable of reducing the RBC number concentration a hundred-fold in 1 mL whole blood per hour. - Highlights: • Simple geometry of commercial, off-the-shelf NdFeB magnet blocks is amenable to generate high fields and open gradients. • Periodic pattern of permanent magnet blocks (tessellation) reduces the number of blocks per separation channel and improves the efficiency of separator design. • Split-flow lateral transport thin (SPLITT) fractionation model predicts 100-fold reduction of red blood cells from 1 mL whole blood sample in 1 h, suitable for laboratory medicine applications.

  11. Tessellated permanent magnet circuits for flow-through, open gradient separations of weakly magnetic materials

    International Nuclear Information System (INIS)

    Moore, Lee R.; Williams, P. Stephen; Chalmers, Jeffrey J.; Zborowski, Maciej

    2017-01-01

    Emerging microfluidic-based cell assays favor label-free red blood cell (RBC) depletion. Magnetic separation of RBC is possible because of the paramagnetism of deoxygenated hemoglobin but the process is slow for open-gradient field configurations. In order to increase the throughput, periodic arrangements of the unit magnets were considered, consisting of commercially available Nd-Fe-B permanent magnets and soft steel flux return pieces. The magnet design is uniquely suitable for multiplexing by magnet tessellation, here meaning the tiling of the magnet assembly cross-sectional plane by periodic repetition of the magnet and the flow channel shapes. The periodic pattern of magnet magnetizations allows a reduction of the magnetic material per channel with minimal distortion of the field cylindrical symmetry inside the magnet apertures. A number of such magnet patterns are investigated for separator performance, size and economy with the goal of designing an open-gradient magnetic separator capable of reducing the RBC number concentration a hundred-fold in 1 mL whole blood per hour. - Highlights: • Simple geometry of commercial, off-the-shelf NdFeB magnet blocks is amenable to generate high fields and open gradients. • Periodic pattern of permanent magnet blocks (tessellation) reduces the number of blocks per separation channel and improves the efficiency of separator design. • Split-flow lateral transport thin (SPLITT) fractionation model predicts 100-fold reduction of red blood cells from 1 mL whole blood sample in 1 h, suitable for laboratory medicine applications.

  12. The free energies of partially open coronal magnetic fields

    Science.gov (United States)

    Low, B. C.; Smith, D. F.

    1993-01-01

    A simple model of the low corona is examined in terms of a static polytropic atmosphere in equilibrium with a global magnetic field. The question posed is whether magnetostatic states with partially open magnetic fields may contain magnetic energies in excess of those in fully open magnetic fields. Based on the analysis presented here, it is concluded that the cross-field electric currents in the pre-eruption corona are a viable source of the bulk of the energies in a mass ejection and its associated flare.

  13. HEART TRANSPLANTATION IN PATIENTS WITH PREVIOUS OPEN HEART SURGERY

    Directory of Open Access Journals (Sweden)

    R. Sh. Saitgareev

    2016-01-01

    Full Text Available Heart Transplantation (HTx to date remains the most effective and radical method of treatment of patients with end-stage heart failure. The defi cit of donor hearts is forcing to resort increasingly to the use of different longterm mechanical circulatory support systems, including as a «bridge» to the follow-up HTx. According to the ISHLT Registry the number of recipients underwent cardiopulmonary bypass surgery increased from 40% in the period from 2004 to 2008 to 49.6% for the period from 2009 to 2015. HTx performed in repeated patients, on the one hand, involves considerable technical diffi culties and high risks; on the other hand, there is often no alternative medical intervention to HTx, and if not dictated by absolute contradictions the denial of the surgery is equivalent to 100% mortality. This review summarizes the results of a number of published studies aimed at understanding the immediate and late results of HTx in patients, previously underwent open heart surgery. The effect of resternotomy during HTx and that of the specifi c features associated with its implementation in recipients previously operated on open heart, and its effects on the immediate and long-term survival were considered in this review. Results of studies analyzing the risk factors for perioperative complications in repeated recipients were also demonstrated. Separately, HTx risks after implantation of prolonged mechanical circulatory support systems were examined. The literature does not allow to clearly defi ning the impact factor of earlier performed open heart surgery on the course of perioperative period and on the prognosis of survival in recipients who underwent HTx. On the other hand, subject to the regular fl ow of HTx and the perioperative period the risks in this clinical situation are justifi ed as a long-term prognosis of recipients previously conducted open heart surgery and are comparable to those of patients who underwent primary HTx. Studies

  14. 2008 LHC Open Days LHC magnets on display

    CERN Multimedia

    2008-01-01

    Over the last few years you’ve probably seen many of the 15 m long blue LHC dipole magnets being ferried around the site. Most of them are underground now, but on the LHC Open Days on 5 and 6 April the magnets will also play a central role on the surface. Installation of one of the LHC dipole magnets on the Saint-Genis roundabout on 7 March. The LHC dipole testing facility with several magnets at various stages of testing. The 27 km ring of the LHC consists of 1232 double-aperture superconducting dipole magnets, 360 short straight sections (SSS) and 114 special SSS for the insertion regions. On the Open Day, you will be able to "Follow the LHC magnets" through different stages around the site, culminating in their descent into the tunnel. Discover all the many components that have to be precisely integrated in the magnet casings, and talk to the engine...

  15. Open magnetic fields in active regions

    International Nuclear Information System (INIS)

    Svestka, Z.; Solodyna, C.V.; Levine, R.H.

    1977-01-01

    Soft X-ray observations confirm that some of the dark gaps seen between interconnecting loops and inner cores of active regions may be loci of open fields, as it has been predicted by global potential extrapolation of photospheric magnetic fields. It seems that the field lines may open only in a later state of the active region development. (Auth.)

  16. Slow decay of magnetic fields in open Friedmann universes

    International Nuclear Information System (INIS)

    Barrow, John D.; Tsagas, Christos G.

    2008-01-01

    Magnetic fields in Friedmann universes can experience superadiabatic growth without departing from conventional electromagnetism. The reason is the relativistic coupling between vector fields and spacetime geometry, which slows down the decay of large-scale magnetic fields in open universes, compared to that seen in perfectly flat models. The result is a large relative gain in magnetic strength that can lead to astrophysically interesting B fields, even if our Universe is only marginally open today

  17. On the helicity of open magnetic fields

    International Nuclear Information System (INIS)

    Prior, C.; Yeates, A. R.

    2014-01-01

    We reconsider the topological interpretation of magnetic helicity for magnetic fields in open domains, and relate this to the relative helicity. Specifically, our domains stretch between two parallel planes, and each of these ends may be magnetically open. It is demonstrated that, while the magnetic helicity is gauge-dependent, its value in any gauge may be physically interpreted as the average winding number among all pairs of field lines with respect to some orthonormal frame field. In fact, the choice of gauge is equivalent to the choice of reference field in the relative helicity, meaning that the magnetic helicity is no less physically meaningful. We prove that a particular gauge always measures the winding with respect to a fixed frame, and propose that this is normally the best choice. For periodic fields, this choice is equivalent to measuring relative helicity with respect to a potential reference field. However, for aperiodic fields, we show that the potential field can be twisted. We prove by construction that there always exists a possible untwisted reference field.

  18. Solar Open Flux Migration from Pole to Pole: Magnetic Field Reversal.

    Science.gov (United States)

    Huang, G-H; Lin, C-H; Lee, L C

    2017-08-25

    Coronal holes are solar regions with low soft X-ray or low extreme ultraviolet intensities. The magnetic fields from coronal holes extend far away from the Sun, and thus they are identified as regions with open magnetic field lines. Coronal holes are concentrated in the polar regions during the sunspot minimum phase, and spread to lower latitude during the rising phase of solar activity. In this work, we identify coronal holes with outward and inward open magnetic fluxes being in the opposite poles during solar quiet period. We find that during the sunspot rising phase, the outward and inward open fluxes perform pole-to-pole trans-equatorial migrations in opposite directions. The migration of the open fluxes consists of three parts: open flux areas migrating across the equator, new open flux areas generated in the low latitude and migrating poleward, and new open flux areas locally generated in the polar region. All three components contribute to the reversal of magnetic polarity. The percentage of contribution from each component is different for different solar cycle. Our results also show that the sunspot number is positively correlated with the lower-latitude open magnetic flux area, but negatively correlated with the total open flux area.

  19. Can a marginally open universe amplify magnetic fields?

    International Nuclear Information System (INIS)

    Shtanov, Yuri; Sahni, Varun

    2013-01-01

    In a series of recent papers, including arXiv:1210.1183, it was claimed that large-scale magnetic fields generated during inflation in a spatially open universe could remain astrophysically significant at the present time since they experienced superadiabatic amplification specific to an open universe. We reexamine this assertion and show that, on the contrary, large-scale magnetic fields in a realistic open universe decay in much the same manner as they would in a spatially flat universe. Consequently, their amplitude today is extremely small (B 0 ∼ −59 G) and is unlikely to be of astrophysical significance

  20. Evolution of open magnetic structures on the sun: the Skylab period

    International Nuclear Information System (INIS)

    Levine, R.H.

    1977-01-01

    High-resolution harmonic analysis of the measured photospheric magnetic field of the Sun is used to construct models of open magnetic structures over a period of 11 solar rotations. The models successfully reproduce the surface location and topology of all coronal holes during the Skylab period. In addition, there is persistent evidence in the models that open field lines are associated with active regions in a systematic way. These associations are listed for the period studied; they suggest that open field lines are a basic feature of solar magnetism. Specific examples of the evolution of coronal holes and of calculated open structures are presented. Quantitative study of the measured field strength within and neighboring a hole confirms the fact that coronal hole regions are indistinguishable by local magnetic properties. However, the calculated field strengths at the footpoints of open field lines within coronal holes show distinct evolutionary patterns and may indicate that, at least in young coronal holes, a significant amount of magnetic flux is closed. Problems of studying magnetic field divergence by using these models are discussed

  1. Particle-in-cell simulations of plasma opening switch with external magnetic field

    International Nuclear Information System (INIS)

    Chen Yulan; Zeng Zhengzhong; Sun Fengju

    2003-01-01

    Fully electromagnetic particle-in-cell simulations are performed to study the effects of an external magnetic field on coaxial plasma opening switch (POS). The simulation results show that POS opening performance can be significantly improved only when external longitudinal magnetic field coils are placed at the cathode side, and an additional azimuthal magnetic field is effective whether the central electrode is of positive or negative polarity. Voltage multiplication coefficient K rises with the additional magnetic field increasing till the electron current is completely magnetically insulated during the opening of POS

  2. FeNi-based flat magnetoimpedance nanostructures with open magnetic flux: New topological approaches

    Energy Technology Data Exchange (ETDEWEB)

    Kurlyandskaya, G.V., E-mail: galina@we.lc.ehu.es [Universidad del País Vasco, UPV/EHU, Dpto. de Electricidad y Electrónica, P.O. Box 644, Bilbao 48080 (Spain); Ural Federal University, Department of Magnetism and Magnetic Nanomaterials, Mira 19, 620002 Ekaterinburg (Russian Federation); Chlenova, A.A. [Ural Federal University, Department of Magnetism and Magnetic Nanomaterials, Mira 19, 620002 Ekaterinburg (Russian Federation); Fernández, E. [Universidad del País Vasco, UPV/EHU, Dpto. de Electricidad y Electrónica, P.O. Box 644, Bilbao 48080 (Spain); Lodewijk, K.J. [Universidad del País Vasco, UPV/EHU, Dpto. de Electricidad y Electrónica, P.O. Box 644, Bilbao 48080 (Spain); Department of Material Sciences, University of Groningen, Nijenborgh 4, 9747 AG Groningen (Netherlands)

    2015-06-01

    Classic flat MI multilayers consist of top and bottom ferromagnetic parts of equal thickness separated by a conductive lead. In previous studies symmetric MI structures were considered because they provide the highest sensitivity with respect to uniform external magnetic fields. There are a number of applications where non-uniform magnetic fields of complex configurations must be detected. Non-symmetric MI structures can be advantageous in this particular case. We describe our experience in design, fabrication and characterization of symmetric and non-symmetric MI multilayers with open magnetic flux. Non-symmetry of the structures was obtained by the deposition of top and bottom ferromagnetic parts of MI element of different thickness. MI responses of the structures with even or odd configurations of the FeNi layers were also considered. - Highlights: • Classic flat MI multilayer consists of ferromagnetic parts of equal thickness separated by a conductive lead. • In previous studies symmetric MI structures were considered. • Non-symmetric MI structures can be advantageous for applications where non-uniform magnetic fields are detected. • MI responses of the structures with even or odd configuration can be very different.

  3. FeNi-based flat magnetoimpedance nanostructures with open magnetic flux: New topological approaches

    International Nuclear Information System (INIS)

    Kurlyandskaya, G.V.; Chlenova, A.A.; Fernández, E.; Lodewijk, K.J.

    2015-01-01

    Classic flat MI multilayers consist of top and bottom ferromagnetic parts of equal thickness separated by a conductive lead. In previous studies symmetric MI structures were considered because they provide the highest sensitivity with respect to uniform external magnetic fields. There are a number of applications where non-uniform magnetic fields of complex configurations must be detected. Non-symmetric MI structures can be advantageous in this particular case. We describe our experience in design, fabrication and characterization of symmetric and non-symmetric MI multilayers with open magnetic flux. Non-symmetry of the structures was obtained by the deposition of top and bottom ferromagnetic parts of MI element of different thickness. MI responses of the structures with even or odd configurations of the FeNi layers were also considered. - Highlights: • Classic flat MI multilayer consists of ferromagnetic parts of equal thickness separated by a conductive lead. • In previous studies symmetric MI structures were considered. • Non-symmetric MI structures can be advantageous for applications where non-uniform magnetic fields are detected. • MI responses of the structures with even or odd configuration can be very different

  4. The Evolution of Open Magnetic Flux Driven by Photospheric Dynamics

    Science.gov (United States)

    Linker, Jon A.; Lionello, Roberto; Mikic, Zoran; Titov, Viacheslav S.; Antiochos, Spiro K.

    2010-01-01

    The coronal magnetic field is of paramount importance in solar and heliospheric physics. Two profoundly different views of the coronal magnetic field have emerged. In quasi-steady models, the predominant source of open magnetic field is in coronal holes. In contrast, in the interchange model, the open magnetic flux is conserved, and the coronal magnetic field can only respond to the photospheric evolution via interchange reconnection. In this view the open magnetic flux diffuses through the closed, streamer belt fields, and substantial open flux is present in the streamer belt during solar minimum. However, Antiochos and co-workers, in the form of a conjecture, argued that truly isolated open flux cannot exist in a configuration with one heliospheric current sheet (HCS) - it will connect via narrow corridors to the polar coronal hole of the same polarity. This contradicts the requirements of the interchange model. We have performed an MHD simulation of the solar corona up to 20R solar to test both the interchange model and the Antiochos conjecture. We use a synoptic map for Carrington Rotation 1913 as the boundary condition for the model, with two small bipoles introduced into the region where a positive polarity extended coronal hole forms. We introduce flows at the photospheric boundary surface to see if open flux associated with the bipoles can be moved into the closed-field region. Interchange reconnection does occur in response to these motions. However, we find that the open magnetic flux cannot be simply injected into closed-field regions - the flux eventually closes down and disconnected flux is created. Flux either opens or closes, as required, to maintain topologically distinct open and closed field regions, with no indiscriminate mixing of the two. The early evolution conforms to the Antiochos conjecture in that a narrow corridor of open flux connects the portion of the coronal hole that is nearly detached by one of the bipoles. In the later evolution, a

  5. THE EVOLUTION OF OPEN MAGNETIC FLUX DRIVEN BY PHOTOSPHERIC DYNAMICS

    International Nuclear Information System (INIS)

    Linker, Jon A.; Lionello, Roberto; Mikic, Zoran; Titov, Viacheslav S.; Antiochos, Spiro K.

    2011-01-01

    The coronal magnetic field is of paramount importance in solar and heliospheric physics. Two profoundly different views of the coronal magnetic field have emerged. In quasi-steady models, the predominant source of open magnetic field is in coronal holes. In contrast, in the interchange model, the open magnetic flux is conserved, and the coronal magnetic field can only respond to the photospheric evolution via interchange reconnection. In this view, the open magnetic flux diffuses through the closed, streamer belt fields, and substantial open flux is present in the streamer belt during solar minimum. However, Antiochos and coworkers, in the form of a conjecture, argued that truly isolated open flux cannot exist in a configuration with one heliospheric current sheet-it will connect via narrow corridors to the polar coronal hole of the same polarity. This contradicts the requirements of the interchange model. We have performed an MHD simulation of the solar corona up to 20 R sun to test both the interchange model and the Antiochos conjecture. We use a synoptic map for Carrington rotation 1913 as the boundary condition for the model, with two small bipoles introduced into the region where a positive polarity extended coronal hole forms. We introduce flows at the photospheric boundary surface to see if open flux associated with the bipoles can be moved into the closed-field region. Interchange reconnection does occur in response to these motions. However, we find that the open magnetic flux cannot be simply injected into closed-field regions-the flux eventually closes down and disconnected flux is created. Flux either opens or closes, as required, to maintain topologically distinct open- and closed-field regions, with no indiscriminate mixing of the two. The early evolution conforms to the Antiochos conjecture in that a narrow corridor of open flux connects the portion of the coronal hole that is nearly detached by one of the bipoles. In the later evolution, a detached

  6. Comments on open-ended magnetic systems for fusion

    International Nuclear Information System (INIS)

    Post, R.F.

    1990-01-01

    Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are ''open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research ''high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux)

  7. Corrections for hysteresis curves for rare earth magnet materials measured by open magnetic circuit methods

    International Nuclear Information System (INIS)

    Nakagawa, Yasuaki

    1996-01-01

    The methods for testing permanent magnets stipulated in the usual industrial standards are so-called closed magnetic circuit methods which employ a loop tracer using an iron-core electromagnet. If the coercivity exceeds the highest magnetic field generated by the electromagnet, full hysteresis curves cannot be obtained. In the present work, magnetic fields up to 15 T were generated by a high-power water-cooled magnet, and the magnetization was measured by an induction method with an open magnetic circuit, in which the effect of a demagnetizing field should be taken into account. Various rare earth magnets materials such as sintered or bonded Sm-Co and Nd-Fe-B were provided by a number of manufacturers. Hysteresis curves for cylindrical samples with 10 nm in diameter and 2 mm, 3.5 mm, 5 mm, 14 mm or 28 mm in length were measured. Correction for the demagnetizing field is rather difficult because of its non-uniformity. Roughly speaking, a mean demagnetizing factor for soft magnetic materials can be used for the correction, although the application of this factor to hard magnetic material is hardly justified. Thus the dimensions of the sample should be specified when the data obtained by the open magnetic circuit method are used as industrial standards. (author)

  8. In situ monitoring the effects of a magnetic field on the open-circuit corrosion states of iron in acidic and neutral solutions

    International Nuclear Information System (INIS)

    Lu Zhanpeng; Yang Wu

    2008-01-01

    The effects of a 0.4 T horizontal magnetic field (HMF) on the open-circuit corrosion states of iron in static aqueous solutions are studied by in situ monitoring the responses of two electrochemical parameters to the applied magnetic field, i.e. the open-circuit potential (OCP) and the current under potentiostatic polarization. The applied magnetic field makes the OCP shift in the noble direction. Withdrawing the magnetic field causes a negative shift of the OCP in acidic solutions, but it does not cause any significant change of OCP in neutral solutions. Imposing a magnetic field induces a cathodic current for iron that was previously potentiostatically polarized at the OCP without magnetic field. Withdrawing the magnetic field induces an anodic current for iron that was previously potentiostatically polarized at the OCP with the magnetic field. The magnetic field effect is more significant in the acid solutions than in the salt solutions. The magnetic field effects on the oxygen reduction and on the activation-controlled iron dissolution reaction are found to be insignificant. The magnetic field effect on the hydrogen reduction reaction on iron in acidic solutions is demonstrated. Results show the possibility that a magnetic field would affect the hydrogen evolution by enhancing the electron-transfer process that has been categorized in the classical electrochemistry kinetics to be the rate-determining process. The memory effect of the magnetic field on the electrochemical reaction is identified and discussed

  9. Magnetically-enhanced open string pair production

    Science.gov (United States)

    Lu, J. X.

    2017-12-01

    We consider the stringy interaction between two parallel stacks of D3 branes placed at a separation. Each stack of D3 branes in a similar fashion carry an electric flux and a magnetic flux with the two sharing no common field strength index. The interaction amplitude has an imaginary part, giving rise to the Schwinger-like pair production of open strings. We find a significantly enhanced rate of this production when the two electric fluxes are almost identical and the brane separation is on the order of string scale. This enhancement will be largest if the two magnetic fluxes are opposite in direction. This novel enhancement results from the interplay of the non-perturbative Schwinger-type pair production due to the electric flux and the stringy tachyon due to the magnetic flux, and may have realistic physical applications.

  10. Open H-shaped permanent magnet structure for NMR imaging

    International Nuclear Information System (INIS)

    Nguyen, V.; Delamare, J.; Yonnet, J.P.

    1996-01-01

    Since NMR imaging at low field is now technically possible, permanent magnets can replace resistive coils or superconducting magnets. This paper reviews most of NMR structures that provide an uniform field using only permanent magnets. We propose a new open H-shaped structure that is simple to manufacture. This structure has been calculated thanks to an optimization program and a calculation method we presente here. It enables to determine with a good accuracy the field created by passive systems composed by permanent magnets and ferromagnetic materials. (author)

  11. Cardiovascular magnetic resonance in adults with previous cardiovascular surgery.

    Science.gov (United States)

    von Knobelsdorff-Brenkenhoff, Florian; Trauzeddel, Ralf Felix; Schulz-Menger, Jeanette

    2014-03-01

    Cardiovascular magnetic resonance (CMR) is a versatile non-invasive imaging modality that serves a broad spectrum of indications in clinical cardiology and has proven evidence. Most of the numerous applications are appropriate in patients with previous cardiovascular surgery in the same manner as in non-surgical subjects. However, some specifics have to be considered. This review article is intended to provide information about the application of CMR in adults with previous cardiovascular surgery. In particular, the two main scenarios, i.e. following coronary artery bypass surgery and following heart valve surgery, are highlighted. Furthermore, several pictorial descriptions of other potential indications for CMR after cardiovascular surgery are given.

  12. Open magnetic fields in active regions

    Science.gov (United States)

    Svestka, Z.; Solodyna, C. V.; Howard, R.; Levine, R. H.

    1977-01-01

    Soft X-ray images and magnetograms of several active regions and coronal holes are examined which support the interpretation that some of the dark X-ray gaps seen between interconnecting loops and inner cores of active regions are foot points of open field lines inside the active regions. Characteristics of the investigated dark gaps are summarized. All the active regions with dark X-ray gaps at the proper place and with the correct polarity predicted by global potential extrapolation of photospheric magnetic fields are shown to be old active regions, indicating that field opening is accomplished only in a late phase of active-region development. It is noted that some of the observed dark gaps probably have nothing in common with open fields, but are either due to the decreased temperature in low-lying portions of interconnecting loops or are the roots of higher and less dense or cooler loops.

  13. Open-Access, Low-Magnetic-Field MRI System for Lung Research

    Science.gov (United States)

    Mair, Ross W.; Rosen, Matthew S.; Tsai, Leo L.; Walsworth, Ronald L.; Hrovat, Mirko I.; Patz, Samuel; Ruset, Iullian C.; Hersman, F. William

    2009-01-01

    An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

  14. Effects of magnetic field exposure on open field behaviour and nociceptive responses in mice.

    Science.gov (United States)

    Del Seppia, Cristina; Mezzasalma, Lorena; Choleris, Elena; Luschi, Paolo; Ghione, Sergio

    2003-09-15

    Results of previous studies have shown that nociceptive sensitivity in male C57 mice is enhanced by exposure to a regular 37 Hz or an irregularly varying (field. In order to test whether these fields affect more generally mouse behaviour, we placed Swiss CD-1 mice in a novel environment (open field test) and exposed them for 2 h to these two different magnetic field conditions. Hence, we analysed how duration and time course of various behavioural patterns (i.e. exploration, rear, edge chew, self-groom, sit, walk and sleep) and nociceptive sensitivity had been affected by such exposure. Nociceptive sensitivity was significantly greater in magnetically treated mice than in controls. The overall time spent in exploratory activities was significantly shorter in both magnetically treated groups (time), than in controls (42%). Conversely, the time spent in sleeping was markedly longer in the treated groups (both 27% of total time) than in controls (11%). These results suggest that exposure to altered magnetic fields induce a more rapid habituation to a novel environment.

  15. Long-term Longitudinal Recurrences of the Open Magnetic Flux Density in the Heliosphere

    Energy Technology Data Exchange (ETDEWEB)

    Dósa, M.; Erdős, G., E-mail: dosa.melinda@wigner.mta.hu [Institute for Particle and Nuclear Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, H-1121 Budapest, Konkoly-Thege Miklós st 29-33 (Hungary)

    2017-04-01

    Open magnetic flux in the heliosphere is determined from the radial component of the magnetic field vector measured onboard interplanetary space probes. Previous Ulysses research has shown remarkable independence of the flux density from heliographic latitude, explained by super-radial expansion of plasma. Here we are investigating whether any longitudinal variation exists in the 50 year long OMNI magnetic data set. The heliographic longitude of origin of the plasma package was determined by applying a correction according to the solar wind travel time. Significant recurrent enhancements of the magnetic flux density were observed throughout solar cycle 23, lasting for several years. Similar, long-lasting recurring features were observed in the solar wind velocity, temperature and the deviation angle of the solar wind velocity vector from the radial direction. Each of the recurrent features has a recurrence period slightly differing from the Carrington rotation rate, although they show a common trend in time. Examining the coronal temperature data of ACE leads to the possible explanation that these long-term structures are caused by slow–fast solar wind interaction regions. A comparison with MESSENGER data measured at 0.5 au shows that these longitudinal magnetic modulations do not exist closer to the Sun, but are the result of propagation.

  16. Plasma opening switch with extrinsic magnetic field

    CERN Document Server

    Dolgachev, G; Maslennikov, D

    2001-01-01

    Summary form only given, as follows. We have demonstrated in series of experiments that plasma opening switch (POS) switching voltage (UPOS) is defined by energy density (w) deposited in the POS plasma. If we then consider a plasma erosion mainly responsible for the effect of POS switching (the erosion effect could be described by Hall or Child-Langmuir models) the energy density (w) could be measured as a function of a system "macro-parameter" such as the initial charging voltage of the capacity storage system (the Marx pulsed voltage generator) UMarx. The POS voltage in this case could be given by UPOS"aw=aUMarx4/7, where a is a constant. This report demonstrates that for the high-impedance POS which has limited charge density transferred through the POS plasma a"2.5 (MV3/7) with no external magnetic field applied. The use of the extrinsic magnetic field allows to increase a up to 3.6 (MV3/7) and to achieve higher voltages at the opening phase - UPOS=3.6UMarx4/7. To verify this approach set of experimental ...

  17. LOW-MASS PLANETS IN PROTOPLANETARY DISKS WITH NET VERTICAL MAGNETIC FIELDS: THE PLANETARY WAKE AND GAP OPENING

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Zhaohuan; Stone, James M.; Rafikov, Roman R., E-mail: zhzhu@astro.princeton.edu, E-mail: jstone@astro.princeton.edu, E-mail: rrr@astro.princeton.edu [Department of Astrophysical Sciences, Princeton University, Princeton, NJ, 08544 (United States)

    2013-05-10

    Some regions in protoplanetary disks are turbulent, while some regions are quiescent (e.g. the dead zone). In order to study how planets open gaps in both inviscid hydrodynamic disk (e.g. the dead zone) and the disk subject to magnetorotational instability (MRI), we carried out both shearing box two-dimensional inviscid hydrodynamical simulations and three-dimensional unstratified magnetohydrodynamical (MHD) simulations (having net vertical magnetic fields) with a planet at the box center. We found that, due to the nonlinear wave steepening, even a low mass planet can open gaps in both cases, in contradiction to the ''thermal criterion'' for gap opening. In order to understand if we can represent the MRI turbulent stress with the viscous {alpha} prescription for studying gap opening, we compare gap properties in MRI-turbulent disks to those in viscous HD disks having the same stress, and found that the same mass planet opens a significantly deeper and wider gap in net vertical flux MHD disks than in viscous HD disks. This difference arises due to the efficient magnetic field transport into the gap region in MRI disks, leading to a larger effective {alpha} within the gap. Thus, across the gap, the Maxwell stress profile is smoother than the gap density profile, and a deeper gap is needed for the Maxwell stress gradient to balance the planetary torque density. Comparison with previous results from net toroidal flux/zero flux MHD simulations indicates that the magnetic field geometry plays an important role in the gap opening process. We also found that long-lived density features (termed zonal flows) produced by the MRI can affect planet migration. Overall, our results suggest that gaps can be commonly produced by low mass planets in realistic protoplanetary disks, and caution the use of a constant {alpha}-viscosity to model gaps in protoplanetary disks.

  18. LOW-MASS PLANETS IN PROTOPLANETARY DISKS WITH NET VERTICAL MAGNETIC FIELDS: THE PLANETARY WAKE AND GAP OPENING

    International Nuclear Information System (INIS)

    Zhu Zhaohuan; Stone, James M.; Rafikov, Roman R.

    2013-01-01

    Some regions in protoplanetary disks are turbulent, while some regions are quiescent (e.g. the dead zone). In order to study how planets open gaps in both inviscid hydrodynamic disk (e.g. the dead zone) and the disk subject to magnetorotational instability (MRI), we carried out both shearing box two-dimensional inviscid hydrodynamical simulations and three-dimensional unstratified magnetohydrodynamical (MHD) simulations (having net vertical magnetic fields) with a planet at the box center. We found that, due to the nonlinear wave steepening, even a low mass planet can open gaps in both cases, in contradiction to the ''thermal criterion'' for gap opening. In order to understand if we can represent the MRI turbulent stress with the viscous α prescription for studying gap opening, we compare gap properties in MRI-turbulent disks to those in viscous HD disks having the same stress, and found that the same mass planet opens a significantly deeper and wider gap in net vertical flux MHD disks than in viscous HD disks. This difference arises due to the efficient magnetic field transport into the gap region in MRI disks, leading to a larger effective α within the gap. Thus, across the gap, the Maxwell stress profile is smoother than the gap density profile, and a deeper gap is needed for the Maxwell stress gradient to balance the planetary torque density. Comparison with previous results from net toroidal flux/zero flux MHD simulations indicates that the magnetic field geometry plays an important role in the gap opening process. We also found that long-lived density features (termed zonal flows) produced by the MRI can affect planet migration. Overall, our results suggest that gaps can be commonly produced by low mass planets in realistic protoplanetary disks, and caution the use of a constant α-viscosity to model gaps in protoplanetary disks.

  19. Improvement of open-type magnetically shielded room composed of magnetic square cylinders by controlling flux path

    International Nuclear Information System (INIS)

    Hirosato, S.; Yamazaki, K.; Tsuruta, T.; Haraguchi, Y.; Kosaka, M.; Gao, Y.; Muramatsu, K.; Kobayashi, K.

    2011-01-01

    We have developed an open-type magnetically shielded room composed of magnetic square cylinders that has been used for an actual MRI in a hospital. To improve shielding performance, we propose here a method to control the path of the magnetic flux in the wall composed of the magnetic square cylinders by changing the magnetic permeability in each direction of the square cylinders spatially. First, we discuss a method to control the magnetic permeability in each direction of the square cylinders independently by inserting slits without changing the outside dimensions of the square cylinders, by using 3-D magnetic field analysis. Then, the effectiveness of the design of controlling the flux pass was shown by magnetic field analysis and experiments. (author)

  20. Expression of the axial magnetic attenuation for a circularly cylindrical magnetic shield with partial openings

    CERN Document Server

    Chang, L H; Luo, G H; Lin, M C

    2002-01-01

    This paper presents a novel empirical formula for evaluating the axial magnetic attenuation of a circularly cylindrical shield with partial openings at both ends, which is derived under the assumption of scaling law with help of the 3-D magnetostatic code TOSCA for computing the magnetic attenuation of some canonical models. Our formula allows a quick evaluation of the magnetic shielding for design application to a superconducting radio-frequency cavity with less than 10% discrepancy in comparison with that obtained from pure numerical simulations.

  1. Does previous open renal surgery or percutaneous nephrolithotomy affect the outcomes and complications of percutaneous nephrolithotomy.

    Science.gov (United States)

    Ozgor, Faruk; Kucuktopcu, Onur; Sarılar, Omer; Toptas, Mehmet; Simsek, Abdulmuttalip; Gurbuz, Zafer Gokhan; Akbulut, Mehmet Fatih; Muslumanoglu, Ahmet Yaser; Binbay, Murat

    2015-11-01

    In this study, we aim to evaluate the effectiveness and safety of PNL in patients with a history of open renal surgery or PNL by comparing with primary patients and to compare impact of previous open renal surgery and PNL on the success and complications of subsequent PNL. Charts of patients, who underwent PNL at our institute, were analyzed retrospectively. Patients were divided into three groups according to history of renal stone surgery. Patients without history of renal surgery were enrolled into Group 1. Other patients with previous PNL and previous open surgery were categorized as Group 2 and Group 3. Preoperative characteristic, perioperative data, stone-free status, and complication rates were compared between the groups. Stone-free status was accepted as completing clearance of stone and residual fragment smaller than 4 mm. Eventually, 2070 patients were enrolled into the study. Open renal surgery and PNL had been done in 410 (Group 2) and 131 (Group 3) patients, retrospectively. The mean operation time was longer (71.3 ± 33.5 min) in Group 2 and the mean fluoroscopy time was longer (8.6 ± 5.0) in Group 3 but there was no statistically significant difference between the groups. Highest stone clearance was achieved in primary PNL patients (81.62%) compared to the other groups (77.10% in Group 2 and 75.61% in Group 3). Stone-free rate was not significantly different between Group 2 and Group 3. Fever, pulmonary complications, and blood transfusion requirement were not statically different between groups but angioembolization was significantly higher in Group 2. Percutaneous nephrolithotomy is a safe and effective treatment modality for patients with renal stones regardless history of previous PNL or open renal surgery. However, history of open renal surgery but not PNL significantly reduced PNL success.

  2. Ballooning modes on open magnetic field lines

    International Nuclear Information System (INIS)

    Hameiri, E.

    1999-01-01

    The ballooning instability on open magnetic field lines is given a thorough mathematical analysis. It is shown that resistive bounding ends (endplates) induce the same stability properties as insulating ends. When unstable, the maximal growth rate increases monotonically with boundary resistivity. An interchange instability may be present, and one necessary condition for its stability is that ∫dl/B be constant on pressure surfaces. (This is an equilibrium existence condition for systems with closed magnetic field lines.) Another necessary condition for interchange stability has the same form as in the closed line case. Precise necessary and sufficient stability criteria are given for various types of bounding ends, including insulating, resistive, and perfectly conducting. copyright 1999 American Institute of Physics

  3. A portable Halbach magnet that can be opened and closed without force: the NMR-CUFF.

    Science.gov (United States)

    Windt, Carel W; Soltner, Helmut; van Dusschoten, Dagmar; Blümler, Peter

    2011-01-01

    Portable equipment for nuclear magnetic resonance (NMR) is becoming increasingly attractive for use in a variety of applications. One of the main scientific challenges in making NMR portable is the design of light-weight magnets that possess a strong and homogeneous field. Existing NMR magnets can provide such magnetic fields, but only for small samples or in small regions, or are rather heavy. Here we show a simple yet elegant concept for a Halbach-type permanent magnet ring, which can be opened and closed with minimal mechanical force. An analytical solution for an ideal Halbach magnet shows that the magnetic forces cancel if the structure is opened at an angle of 35.3° relative to its poles. A first prototype weighed only 3.1 kg, and provided a flux density of 0.57 T with a homogeneity better than 200 ppm over a spherical volume of 5mm in diameter without shimming. The force needed to close it was found to be about 20 N. As a demonstration, intact plants were imaged and water (xylem) flow measured. Magnets of this type (NMR-CUFF = Cut-open, Uniform, Force Free) are ideal for portable use and are eminently suited to investigate small or slender objects that are part of a larger or immobile whole, such as branches on a tree, growing fruit on a plant, or non-metallic tubing in industrial installations. This new concept in permanent-magnet design enables the construction of openable, yet strong and homogeneous magnets, which aside from use in NMR or MRI could also be of interest for applications in accelerators, motors, or magnetic bearings. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Dependence of the amount of open magnetic flux on the direction of the interplanetary magnetic field

    International Nuclear Information System (INIS)

    Akasofu, S.I.; Ahn, B.H.

    1980-01-01

    The power generated by the solar wind-magnetosphere dynamo is proportional to the amount of the open magnetic flux phi. It is difficult to use this fact in determining observationally the dependence of phi on the orientation of the interplanetary magnetic field vector. It is shown that, for a simple vacuum superposition of the earth's dipole field and a uniform magnetic field, PHI is very closely proportional to sin(theta/2) for a wide range of the intensity of the uniform field, where theta denotes the polar angle of the interplanetary magnetic field vector in the Y-Z plane of solar-magnetospheric coordinates. (author)

  5. Identifying open magnetic field regions of the Sun and their heliospheric counterparts

    Science.gov (United States)

    Krista, L. D.; Reinard, A.

    2017-12-01

    Open magnetic regions on the Sun are either long-lived (coronal holes) or transient (dimmings) in nature. Both phenomena are fundamental to our understanding of the solar behavior as a whole. Coronal holes are the sources of high-speed solar wind streams that cause recurrent geomagnetic storms. Furthermore, the variation of coronal hole properties (area, location, magnetic field strength) over the solar activity cycle is an important marker of the global evolution of the solar magnetic field. Dimming regions, on the other hand, are short-lived coronal holes that often emerge in the wake of solar eruptions. By analyzing their physical properties and their temporal evolution, we aim to understand their connection with their eruptive counterparts (flares and coronal mass ejections) and predict the possibility of a geomagnetic storm. The author developed the Coronal Hole Automated Recognition and Monitoring (CHARM) and the Coronal Dimming Tracker (CoDiT) algorithms. These tools not only identify but track the evolution of open magnetic field regions. CHARM also provides daily coronal hole maps, that are used for forecasts at the NOAA Space Weather Prediction Center. Our goal is to better understand the processes that give rise to eruptive and non-eruptive open field regions and investigate how these regions evolve over time and influence space weather.

  6. Plasma injection from the independent SHF-source in the open configuration 2. Magnetic fields of magnetic mirror configurations

    International Nuclear Information System (INIS)

    Beriya, Z.R.; Gogashvili, G.E.; Nanobashvili, S.I.

    1992-01-01

    The investigation was aimed at studying the characteristics and properties of plasma injected from independent stationary SHF source into an open magnetic trap of mirror geometry within a wide range of change in the experimental conditions. The investigations were primarily based on measurements of the distribution of charged particles in a plasma along the trap and on the dependence of the concentration on plasma production conditions in a SHF source. It is shown that the aggregate of the experimental data enables a conclusion that independent of SHF plasma can be succesfully used for filling on open magnetic trap of mirror configuration with plasma

  7. THE TOPOLOGICAL CHANGES OF SOLAR CORONAL MAGNETIC FIELDS. II. THE RECLOSING OF AN OPENED FIELD

    International Nuclear Information System (INIS)

    Low, B. C.; Janse, A. M.

    2009-01-01

    This is a study of the spontaneous formation of current sheets responding to the closing of an opened magnetic field by resistive reconnection in an electrically, highly conducting atmosphere outside a unit sphere. Pairs of initial-final equilibrium states are calculated explicitly, taking the field to be composed of three systems of untwisted flux in both states. In the initial state, two of the three flux systems are closed potential fields whereas the third system contains an equilibrium current sheet that keeps the potential fields on its two sides globally open. The final state is an everywhere potential field, with all three flux systems closed, produced by the resistive dissipation of the current sheet in the initial state. The unit sphere is taken to be a rigid, perfectly conducting wall during reconnection, so that the normal flux distribution is unchanged on the unit sphere. Field solutions subject to this unchanging boundary condition are obtained with and without the assumption of axisymmetry. The mathematical model has been designed to show that the topological changes produced by the current-sheet dissipation are simple under axisymmetry but radically different in the absence of axisymmetry, a fundamental point established in the first paper of this series. In the general case, the topological changes imply that other current sheets must have formed. Some of these current sheets form on the separatrix flux surfaces of the multipolar field. Others form throughout the closed-flux systems induced by volumetric changes. The opening and reclosing of magnetic fields during a solar coronal mass ejection may produce a multitude of current sheets not previously anticipated in the current understanding of this phenomenon. Basic to this study is a general topological property of magnetic flux tubes treated separately in the Appendix.

  8. Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface†

    Science.gov (United States)

    Long, Zhicheng; Shetty, Abhishek M.; Solomon, Michael J.; Larson, Ronald G.

    2010-01-01

    We systematically investigate droplet movement, coalescence, and splitting on an open hydrophobic surface. These processes are actuated by magnetic beads internalized in an oil-coated aqueous droplet using an external magnet. Results are organized into an ‘operating diagram’ that describes regions of droplet stable motion, breakage, and release from the magnet. The results are explained theoretically with a simple model that balances magnetic, friction, and capillary-induced drag forces and includes the effects of particle type, droplet size, surrounding oil layer, surface tension, and viscosity. Finally, we discuss the implications of the results for the design of magnet-actuated droplet systems for applications such as nucleic acid purification, immunoassay and drug delivery. PMID:19458864

  9. Development of fast opening magnetic valve for JT-60 pellet injector

    International Nuclear Information System (INIS)

    Hiratsuka, Hajime; Kawasaki, Kouzo; Takatsu, Hideyuki; Miyo, Yasuhiko; Yoshioka, Yuji; Ohta, Kazuya; Shimizu, Masatsugu; Onozuka, Masanori; Uchikawa, Takashi; Iwamoto, Syuichi; Hashiri, Noboru

    1989-01-01

    A pneumatic four-pellet injector (JT-60 pellet injector) has been constructed for JT-60 in May, 1988. A fast opening magnetically driven propellant gas injection valve has been developed for JT-60 pellet injector. This valve can accelerate four cylindrical pellets, two 3.8 mm diameter by 3.8 mm and two 2.7 mm diameter by 2.7 mm, to greater than 1.6 km/s with propellent gas of up to 50 bar. It is now successfully in use in JT-60, contributing to plasma studies. In this paper the outline of a newly developed fast opening magnetic valve and the results of performance tests are presented. (author). 6 figs.; 1 tab

  10. Does previous open surgical experience have any influence on robotic surgery simulation exercises?

    Science.gov (United States)

    Cumpanas, Alin Adrian; Bardan, Razvan; Ferician, Ovidiu Catalin; Latcu, Silviu Constantin; Duta, Ciprian; Lazar, Fulger Octavian

    2017-12-01

    Within the last years, there has been a trend in many hospitals to switch their surgical activity from open/laparoscopic procedures to robotic surgery. Some open surgeons have been shifting their activity to robotic surgery. It is still unclear whether there is a transfer of open surgical skills to robotic ones. To evaluate whether such transfer of skills occurs and to identify which specific skills are more significantly transferred from the operative table to the console. Twenty-five volunteers were included in the study, divided into 2 groups: group A (15 participants) - medical students (without any surgical experience in open, laparoscopic or robotic surgery); and group B (10 participants) - surgeons with exclusively open surgical experience, without any previous laparoscopic or robotic experience. Participants were asked to complete 3 robotic simulator console exercises structured from the easiest one (Peg Board) to the toughest one (Sponge Suture). Overall scores for each exercise as well as specific metrics were compared between the two groups. There were no significant differences between overall scores of the two groups for the easiest task. Overall scores were better for group B as the exercises got more complex. For the intermediate and high-difficulty level exercises, most of the specific metrics were better for group B, with the exception of the working master space item. Our results suggest that the open surgical skills transfer to robotic skills, at least for the very beginning of the training process.

  11. Magnetic field propagation in a two ion species planar plasma opening switch

    International Nuclear Information System (INIS)

    Strauss, H. R.; Doron, R.; Arad, R.; Rubinstein, B.; Maron, Y.; Fruchtman, A.

    2007-01-01

    Three fluid plasma evolution equations are applied to the problem of magnetic field propagation in a planar plasma opening switch. For certain initial conditions in which Hall parameter H∼1, magnetic field penetration due to the Hall field, initially, as expected, either opposes or adds to the hydromagnetic pushing, depending on the polarity of the magnetic field relative to the density gradient. Later, however, the plasma pushing by the magnetic field is found in the case studied here to modify the plasma density in a way that the density gradient tends to align with the magnetic field gradient, effectively turning off the Hall effect. The penetration of the magnetic field then ceases and plasma pushing becomes the dominant process

  12. Shear-induced opening of the coronal magnetic field

    Science.gov (United States)

    Wolfson, Richard

    1995-01-01

    This work describes the evolution of a model solar corona in response to motions of the footpoints of its magnetic field. The mathematics involved is semianalytic, with the only numerical solution being that of an ordinary differential equation. This approach, while lacking the flexibility and physical details of full MHD simulations, allows for very rapid computation along with complete and rigorous exploration of the model's implications. We find that the model coronal field bulges upward, at first slowly and then more dramatically, in response to footpoint displacements. The energy in the field rises monotonically from that of the initial potential state, and the field configuration and energy appraoch asymptotically that of a fully open field. Concurrently, electric currents develop and concentrate into a current sheet as the limiting case of the open field is approached. Examination of the equations shows rigorously that in the asymptotic limit of the fully open field, the current layer becomes a true ideal MHD singularity.

  13. A hybrid analytical model for open-circuit field calculation of multilayer interior permanent magnet machines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhen [School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Xia, Changliang [School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Tianjin Engineering Center of Electric Machine System Design and Control, Tianjin 300387 (China); Yan, Yan, E-mail: yanyan@tju.edu.cn [School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China); Geng, Qiang [Tianjin Engineering Center of Electric Machine System Design and Control, Tianjin 300387 (China); Shi, Tingna [School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2017-08-01

    Highlights: • A hybrid analytical model is developed for field calculation of multilayer IPM machines. • The rotor magnetic field is calculated by the magnetic equivalent circuit method. • The field in the stator and air-gap is calculated by subdomain technique. • The magnetic scalar potential on rotor surface is modeled as trapezoidal distribution. - Abstract: Due to the complicated rotor structure and nonlinear saturation of rotor bridges, it is difficult to build a fast and accurate analytical field calculation model for multilayer interior permanent magnet (IPM) machines. In this paper, a hybrid analytical model suitable for the open-circuit field calculation of multilayer IPM machines is proposed by coupling the magnetic equivalent circuit (MEC) method and the subdomain technique. In the proposed analytical model, the rotor magnetic field is calculated by the MEC method based on the Kirchhoff’s law, while the field in the stator slot, slot opening and air-gap is calculated by subdomain technique based on the Maxwell’s equation. To solve the whole field distribution of the multilayer IPM machines, the coupled boundary conditions on the rotor surface are deduced for the coupling of the rotor MEC and the analytical field distribution of the stator slot, slot opening and air-gap. The hybrid analytical model can be used to calculate the open-circuit air-gap field distribution, back electromotive force (EMF) and cogging torque of multilayer IPM machines. Compared with finite element analysis (FEA), it has the advantages of faster modeling, less computation source occupying and shorter time consuming, and meanwhile achieves the approximate accuracy. The analytical model is helpful and applicable for the open-circuit field calculation of multilayer IPM machines with any size and pole/slot number combination.

  14. Magnetar giant flares in multipolar magnetic fields. I. Fully and partially open eruptions of flux ropes

    International Nuclear Information System (INIS)

    Huang, Lei; Yu, Cong

    2014-01-01

    We propose a catastrophic eruption model for the enormous energy release of magnetars during giant flares, in which a toroidal and helically twisted flux rope is embedded within a force-free magnetosphere. The flux rope stays in stable equilibrium states initially and evolves quasi-statically. Upon the loss of equilibrium, the flux rope cannot sustain the stable equilibrium states and erupts catastrophically. During the process, the magnetic energy stored in the magnetosphere is rapidly released as the result of destabilization of global magnetic topology. The magnetospheric energy that could be accumulated is of vital importance for the outbursts of magnetars. We carefully establish the fully open fields and partially open fields for various boundary conditions at the magnetar surface and study the relevant energy thresholds. By investigating the magnetic energy accumulated at the critical catastrophic point, we find that it is possible to drive fully open eruptions for dipole-dominated background fields. Nevertheless, it is hard to generate fully open magnetic eruptions for multipolar background fields. Given the observational importance of the multipolar magnetic fields in the vicinity of the magnetar surface, it would be worthwhile to explore the possibility of the alternative eruption approach in multipolar background fields. Fortunately, we find that flux ropes may give rise to partially open eruptions in the multipolar fields, which involve only partial opening of background fields. The energy release fractions are greater for cases with central-arcaded multipoles than those with central-caved multipoles that emerged in background fields. Eruptions would fail only when the centrally caved multipoles become extremely strong.

  15. Performance of magnetically-injected-plasma opening switches on the particle beam fusion accelerator 2

    International Nuclear Information System (INIS)

    Rochau, G.E.; McDaniel, D.H.; Mendel, C.W.; Sweeney, M.A.; Moore, W.B.S.; Mowrer, G.R.; Zagar, D.M.

    1990-01-01

    Plasma opening switch (POS) experiments have been performed on the PBFA II ion beam accelerator to develop a switch which will provide voltage and power gain to an applied-B lithium ion diode. These experiments have successfully coupled power to electron and ion beam diodes using a Magnetically-Injected-Plasma (MIP) POS. Carbon plasma with electron densities of 1 x 10 12 to 2 x 10 13 /cm 3 have been injected from the anode into the 8 cm gap of the 20-ohm Magnetically-Insulated-Transmission Line (MITL) of PBFA II along a B r,z magnetic field. The MIP switch uses the inertia of the plasma to keep the switch closed and the magnetic pressure of B θ from the conduction current to open the switch. The configuration of the injecting magnetic field and the plasma source has a significant effect on the efficiency of coupling power to high impedance loads. Plasma near the center of the injecting magnetic field limits the opening impedance of the switch and subsequently the power delivered to the load. The axial location of the switch with respect to the load has also been identified as a critical parameter in increasing the coupling efficiency. A length of 10 to 20 cm of MITL between the POS and the load has increased the power delivered to the load. Data on switch performance with high impedance loads and factors which improved performance are discussed

  16. Intrinsic magnetism and spontaneous band gap opening in bilayer silicene and germanene.

    Science.gov (United States)

    Wang, Xinquan; Wu, Zhigang

    2017-01-18

    It has been long sought to create magnetism out of simple non-magnetic materials, such as silicon and germanium. Here we show that intrinsic magnetism exists in bilayer silicene and germanene with no need to cut, etch, or dope. Unlike bilayer graphene, strong covalent interlayer bonding formed in bilayer silicene and germanene breaks the original π-bonding network of each layer, leaving the unbonded electrons unpaired and localized to carry magnetic moments. These magnetic moments then couple ferromagnetically within each layer while antiferromagnetically across two layers, giving rise to an infinite magnetic sheet with structural integrity and magnetic homogeneity. Furthermore, this unique magnetic ordering results in fundamental band gaps of 0.55 eV and 0.32 eV for bilayer silicene and germanene, respectively. The integration of intrinsic magnetism and spontaneous band gap opening makes bilayer silicene and germanene attractive for future nanoelectronics as well as spin-based computation and data storage.

  17. The effects of previous open renal stone surgery types on PNL outcomes.

    Science.gov (United States)

    Ozgor, Faruk; Kucuktopcu, Onur; Ucpinar, Burak; Sarilar, Omer; Erbin, Akif; Yanaral, Fatih; Sahan, Murat; Binbay, Murat

    2016-01-01

    Our aim was to demonstrate the effect of insicion of renal parenchyma during open renal stone surgery (ORSS) on percutaneous nephrolithotomy (PNL) outcomes. Patients with history of ORSS who underwent PNL operation between June 2005 and June 2015 were analyzed retrospectively. Patients were divided into two groups according to their type of previous ORSS. Patients who had a history of ORSS with parenchymal insicion, such as radial nephrotomies, anatrophic nephrolithotomy, lower pole resection, and partial nephrectomy, were included in Group 1. Other patients with a history of open pyelolithotomy were enrolled in Group 2. Preoperative characteristics, perioperative data, stone-free status, and complications were compared between the groups. Stone-free status was defined as complete clearance of stone(s) or presence of residual fragments smaller than 4 mm. The retrospective nature of our study, different experience level of surgeons, and lack of the evaluation of anesthetic agents and cost of procedures were limitations of our study. 123 and 111 patients were enrolled in Groups 1 and 2, respectively. Preoperative characteristics were similar between groups. In Group 1, the mean operative time was statistically longer than in Group 2 (p=0.013). Stone-free status was significantly higher in Group 2 than in Group 1 (p=0.027). Complication rates were similar between groups. Hemorrhage requiring blood transfusion was the most common complication in both groups (10.5% vs. 9.9%). Our study demonstrated that a history of previous ORSS with parenchymal insicion significantly reduces the success rates of PNL procedure.

  18. OPEN CLUSTERS AS PROBES OF THE GALACTIC MAGNETIC FIELD. I. CLUSTER PROPERTIES

    Energy Technology Data Exchange (ETDEWEB)

    Hoq, Sadia; Clemens, D. P., E-mail: shoq@bu.edu, E-mail: clemens@bu.edu [Institute for Astrophysical Research, 725 Commonwealth Avenue, Boston University, Boston, MA 02215 (United States)

    2015-10-15

    Stars in open clusters are powerful probes of the intervening Galactic magnetic field via background starlight polarimetry because they provide constraints on the magnetic field distances. We use 2MASS photometric data for a sample of 31 clusters in the outer Galaxy for which near-IR polarimetric data were obtained to determine the cluster distances, ages, and reddenings via fitting theoretical isochrones to cluster color–magnitude diagrams. The fitting approach uses an objective χ{sup 2} minimization technique to derive the cluster properties and their uncertainties. We found the ages, distances, and reddenings for 24 of the clusters, and the distances and reddenings for 6 additional clusters that were either sparse or faint in the near-IR. The derived ranges of log(age), distance, and E(B−V) were 7.25–9.63, ∼670–6160 pc, and 0.02–1.46 mag, respectively. The distance uncertainties ranged from ∼8% to 20%. The derived parameters were compared to previous studies, and most cluster parameters agree within our uncertainties. To test the accuracy of the fitting technique, synthetic clusters with 50, 100, or 200 cluster members and a wide range of ages were fit. These tests recovered the input parameters within their uncertainties for more than 90% of the individual synthetic cluster parameters. These results indicate that the fitting technique likely provides reliable estimates of cluster properties. The distances derived will be used in an upcoming study of the Galactic magnetic field in the outer Galaxy.

  19. Structural and magnetic properties of {open_quotes}expanded{close_quotes} Mn

    Energy Technology Data Exchange (ETDEWEB)

    Grigorov, I.L.; Walker, J.C. [Department of Physics and Astronomy, The Johns Hopkins University, Baltimore, Maryland21218 (United States); Hawley, M.E.; Brown, G.W. [Materials Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico87545 (United States); Luett, M.; Fitzsimmons, M.R. [Manuel Lujan Jr. Neutron Scattering Center, Los Alamos National Laboratory, Los Alamos, New Mexico87545 (United States)

    1998-06-01

    Structural and magnetic properties of {open_quotes}expanded{close_quotes} Mn deposited on (111) oriented fcc noble metals were studied with single-crystal x-ray diffraction and exchange bias measurements. A single peak corresponding to this phase was found at momentum transfer q=2.86{Angstrom}{sup {minus}1} along six equivalent [11{bar 2}] directions of the noble metal substrate. Magnetic hysteresis of the field cooled Fe/Mn bilayers exhibited a characteristic shift along the field axis, indicating antiferromagnetic order in the expanded Mn with T{sub N}{ge}20K. The magnetic and structural data are consistent with understanding the expanded phase as trigonally distorted {alpha}-Mn. {copyright} {ital 1998 American Institute of Physics.}

  20. Oval gradient coils for an open magnetic resonance imaging system with a vertical magnetic field.

    Science.gov (United States)

    Matsuzawa, Koki; Abe, Mitsushi; Kose, Katsumi; Terada, Yasuhiko

    2017-05-01

    Existing open magnetic resonance imaging (MRI) systems use biplanar gradient coils for the spatial encoding of signals. We propose using novel oval gradient coils for an open vertical-field MRI. We designed oval gradients for a 0.3T open MRI system and showed that such a system could outperform a traditional biplanar gradient system while maintaining adequate gradient homogeneity and subject accessibility. Such oval gradient coils would exhibit high efficiency, low inductance and resistance, and high switching capability. Although the designed oval Y and Z coils showed more heat dissipation and less cooling capability than biplanar coils with the same gap, they showed an efficient heat-dissipation path to the surrounding air, which would alleviate the heat problem. The performance of the designed oval-coil system was demonstrated experimentally by imaging a human hand. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Open-loop correction for an eddy current dominated beam-switching magnet.

    Science.gov (United States)

    Koseki, K; Nakayama, H; Tawada, M

    2014-04-01

    A beam-switching magnet and the pulsed power supply it requires have been developed for the Japan Proton Accelerator Research Complex. To switch bunched proton beams, the dipole magnetic field must reach its maximum value within 40 ms. In addition, the field flatness should be less than 5 × 10(-4) to guide each bunched beam to the designed orbit. From a magnetic field measurement by using a long search coil, it was found that an eddy current in the thick endplates and laminated core disturbs the rise of the magnetic field. The eddy current also deteriorates the field flatness over the required flat-top period. The measured field flatness was 5 × 10(-3). By using a double-exponential equation to approximate the measured magnetic field, a compensation pattern for the eddy current was calculated. The integrated magnetic field was measured while using the newly developed open-loop compensation system. A field flatness of less than 5 × 10(-4), which is an acceptable value, was achieved.

  2. Magnetic trapping of energetic particles on open dayside boundary layer flux tubes

    International Nuclear Information System (INIS)

    Cowley, S.W.H.; Lewis, Z.V.

    1990-01-01

    Both simple as well as detailed empirical magnetic models of the Earth's dayside magnetosphere suggest that field lines near the magnetopause boundary in the noon quadrant (∼ 09:00 to ∼ 15:00 M.L.T.) possess an unusual property due to the compressive effect of the impinging solar wind flow, namely that the equatorial region represents a local maximum in the magnetic field strength, and not a minimum as elsewhere in the magnetosphere. In this region the field lines can therefore support two distinct particle populations, those which bounce across the equator between mirror points on either side, and those which are trapped about the off-equatorial field strength minima and are confined to one side of the equator. When these field lines become magnetically open due to the occurrence of magnetic reconnection at the equatorial magnetopause, the former particles will rapidly escape into the magnetosheath by field-aligned flow, while the latter population may be sustained within the boundary layer over many bounce periods, as the flux tubes contract and move tailward. Consequently, trapped distributions of energetic particles may commonly occur on open field lines in the dayside boundary layer in the noon quadrant, particularly at high latitudes. The existence of such particles is thus not an infallible indicator of the presence of closed magnetic field lines in this region. At earlier and later local times, however, the boundary layer field lines revert to possessing a minimum in the field strength at the equator. (author)

  3. Overview of stoppering of open magnetic containment systems for controlled fusion

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Lichtenberg, A.J.; Dolan, T.J.

    1977-06-01

    Magnetic confinement systems with the field lines leading out of the system are subject to end loss. The rate of end loss must be reduced to a sufficiently small value in a reactor such that fusion energy is generated more rapidly than energy is lost. The basic open ended systems either have too high an end loss to satisfy the reactor criterion (single mirrors and cusps), or are too long to be considered practical (long solenoids). Various end stoppering schemes have been proposed to reduce the end loss of open ended systems, and thus make the energy balance more favorable. The end stoppering techniques reviewed in this paper are electrostatic, r.f., magnetic, material walls, and hybrid systems. We summarize here the more important characteristics and the potentialities of the first three methods of end stoppering. End stoppering with material walls has been insufficiently explored for further comment and hybrid systems, being mainly beyond the scope of this report, have been summarized in the main text

  4. A hybrid analytical model for open-circuit field calculation of multilayer interior permanent magnet machines

    Science.gov (United States)

    Zhang, Zhen; Xia, Changliang; Yan, Yan; Geng, Qiang; Shi, Tingna

    2017-08-01

    Due to the complicated rotor structure and nonlinear saturation of rotor bridges, it is difficult to build a fast and accurate analytical field calculation model for multilayer interior permanent magnet (IPM) machines. In this paper, a hybrid analytical model suitable for the open-circuit field calculation of multilayer IPM machines is proposed by coupling the magnetic equivalent circuit (MEC) method and the subdomain technique. In the proposed analytical model, the rotor magnetic field is calculated by the MEC method based on the Kirchhoff's law, while the field in the stator slot, slot opening and air-gap is calculated by subdomain technique based on the Maxwell's equation. To solve the whole field distribution of the multilayer IPM machines, the coupled boundary conditions on the rotor surface are deduced for the coupling of the rotor MEC and the analytical field distribution of the stator slot, slot opening and air-gap. The hybrid analytical model can be used to calculate the open-circuit air-gap field distribution, back electromotive force (EMF) and cogging torque of multilayer IPM machines. Compared with finite element analysis (FEA), it has the advantages of faster modeling, less computation source occupying and shorter time consuming, and meanwhile achieves the approximate accuracy. The analytical model is helpful and applicable for the open-circuit field calculation of multilayer IPM machines with any size and pole/slot number combination.

  5. Hybrid Simulation of Supersonic Flow of Weakly Ionized Plasma along Open Field Magnetic Line Effect of Background Pressure

    Science.gov (United States)

    Laosunthara, Ampan; Akatsuka, Hiroshi

    2016-09-01

    In previous study, we experimentally examined physical properties of supersonic flow of weakly ionized expanding arc-jet plasma through an open magnetic field line (Bmax 0.16T). We found supersonic velocity of helium plasma up to Mach 3 and the space potential drop at the end of the magnets. To understand the plasma in numerical point of view, the flows of ion and neutral are treated by particle-based Direct Simulation Monte Carlo (DSMC) method, electron is treated as a fluid. The previous numerical study, we assumed 2 conditions. Ion and electron temperatures were the same (LTE condition). Ion and electron velocities were the same (current-free condition). We found that ion velocity decreased by collision with residual gas molecules (background pressure). We also found that space potential changing with background pressure. In other words, it was indicated that electric field exists and the current-free assumption is not proper. In this study, we add electron continuity and electron momentum equations to obtain electron velocity and space potential. We find that space potential changing with background pressure slightly. It is indicated that electron is essential to space potential formation than ion.

  6. Magnetic field effects on the open circuit potential of ferromagnetic electrodes in corroding solutions.

    Science.gov (United States)

    Dass, Amala; Counsil, Joseph A; Gao, Xuerong; Leventis, Nicholas

    2005-06-02

    Magnetic fields shift the open circuit potential (OCP) of ferromagnetic electrodes (Fe, Co, and Ni) in corroding solutions. The OCP changes we observe (a) follow the series Fe>Co>Ni; (b) increase with the magnetic flux density; (c) reach a maximum with disk electrodes approximately 1 mm in diameter; and (d) depend on the orientation of the electrode. We report that when the surface of the electrode is oriented parallel (theta = 90 degrees) or perpendicular (theta = 0 degrees) to the magnetic field, the open circuit potential moves in opposite directions (positive and negative, respectively) with the largest changes occurring when the electrode surface is parallel to the magnetic field. Nonconvective sleeve electrodes produce the same behavior. The overall experimental evidence suggests that the magnetic field changes the OCP by modifying the surface concentrations of the paramagnetic participants in the corrosion process of the ferromagnetic electrode by species in solution; this in turn is accomplished by imposing a field-gradient driven mode of mass transfer upon paramagnetic species in solution (magnetophoresis). Simulations of the magnetic field around the ferromagnetic electrode at the two extreme orientations considered here show that in one case (theta = 90 degrees) field gradients actually repel, while in the other case (theta = 0 degrees) they attract paramagnetic species in the vicinity of the electrode.

  7. Energy buildup in sheared force-free magnetic fields

    Science.gov (United States)

    Wolfson, Richard; Low, Boon C.

    1992-01-01

    Photospheric displacement of the footpoints of solar magnetic field lines results in shearing and twisting of the field, and consequently in the buildup of electric currents and magnetic free energy in the corona. The sudden release of this free energy may be the origin of eruptive events like coronal mass ejections, prominence eruptions, and flares. An important question is whether such an energy release may be accompanied by the opening of magnetic field lines that were previously closed, for such open field lines can provide a route for matter frozen into the field to escape the sun altogether. This paper presents the results of numerical calculations showing that opening of the magnetic field is permitted energetically, in that it is possible to build up more free energy in a sheared, closed, force-free magnetic field than is in a related magnetic configuration having both closed and open field lines. Whether or not the closed force-free field attains enough energy to become partially open depends on the form of the shear profile; the results presented compare the energy buildup for different shear profiles. Implications for solar activity are discussed briefly.

  8. Effects of a nonuniform open magnetic field on the plasma presheath

    International Nuclear Information System (INIS)

    Sato, Kunihiro; Miyawaki, Fujio

    1991-01-01

    Effects of a nonuniform magnetic field on the plasma presheath is numerically investigated using the plasma equation for a collisionless plasma with a finite-temperature particle source. The present calculation confirms that analytical solutions previously published by the authors are available over a wide range of mirror ratio. Potential drop in the presheath, which considerably depends on both the magnetic strength profile and the spatial distribution of the particle source, is remarkably increased by applying an expanding magnetic field when plasma particles are generated in the inner part of the plasma. An effect of a nonuniform magnetic field on sheath formation is also discussed by using the calculated ion distribution function. If the plasma equation has no singularity at the sheath edge, its solution satisfies the generalized Bohm criterion with the inequality sign in the expanding magnetic field. (author)

  9. Open magnetic resonance imaging using titanium-zirconium needles: improved accuracy for interstitial brachytherapy implants?

    International Nuclear Information System (INIS)

    Popowski, Youri; Hiltbrand, Emile; Joliat, Dominique; Rouzaud, Michel

    2000-01-01

    Purpose: To evaluate the benefit of using an open magnetic resonance (MR) machine and new MR-compatible needles to improve the accuracy of brachytherapy implants in pelvic tumors. Methods and Materials: The open MR machine, foreseen for interventional procedures, allows direct visualization of the pelvic structures that are to be implanted. For that purpose, we have developed MR- and CT-compatible titanium-zirconium (Ti-Zr) brachytherapy needles that allow implantations to be carried out under the magnetic field. In order to test the technical feasibility of this new approach, stainless steel (SS) and Ti-Zr needles were first compared in a tissue-equivalent phantom. In a second step, two patients implanted with Ti-Zr needles in the brachytherapy operating room were scanned in the open MR machine. In a third phase, four patients were implanted directly under open MR control. Results: The artifacts induced by both materials were significantly different, strongly favoring the Ti-Zr needles. The implantation in both first patients confirmed the excellent quality of the pictures obtained with the needles in vivo and showed suboptimal implant geometry in both patients. In the next 4 patients, the tumor could be punctured with excellent accuracy, and the adjacent structures could be easily avoided. Conclusion: We conclude that open MR using MR-compatible needles is a very promising tool in brachytherapy, especially for pelvic tumors

  10. Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging.

    Science.gov (United States)

    Chu, Po-Chun; Chai, Wen-Yen; Tsai, Chih-Hung; Kang, Shih-Tsung; Yeh, Chih-Kuang; Liu, Hao-Li

    2016-09-15

    Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.

  11. The Open Flux Problem

    Science.gov (United States)

    Linker, J. A.; Caplan, R. M.; Downs, C.; Riley, P.; Mikic, Z.; Lionello, R.; Henney, C. J.; Arge, C. N.; Liu, Y.; Derosa, M. L.; Yeates, A.; Owens, M. J.

    2017-10-01

    The heliospheric magnetic field is of pivotal importance in solar and space physics. The field is rooted in the Sun’s photosphere, where it has been observed for many years. Global maps of the solar magnetic field based on full-disk magnetograms are commonly used as boundary conditions for coronal and solar wind models. Two primary observational constraints on the models are (1) the open field regions in the model should approximately correspond to coronal holes (CHs) observed in emission and (2) the magnitude of the open magnetic flux in the model should match that inferred from in situ spacecraft measurements. In this study, we calculate both magnetohydrodynamic and potential field source surface solutions using 14 different magnetic maps produced from five different types of observatory magnetograms, for the time period surrounding 2010 July. We have found that for all of the model/map combinations, models that have CH areas close to observations underestimate the interplanetary magnetic flux, or, conversely, for models to match the interplanetary flux, the modeled open field regions are larger than CHs observed in EUV emission. In an alternative approach, we estimate the open magnetic flux entirely from solar observations by combining automatically detected CHs for Carrington rotation 2098 with observatory synoptic magnetic maps. This approach also underestimates the interplanetary magnetic flux. Our results imply that either typical observatory maps underestimate the Sun’s magnetic flux, or a significant portion of the open magnetic flux is not rooted in regions that are obviously dark in EUV and X-ray emission.

  12. The Open Flux Problem

    Energy Technology Data Exchange (ETDEWEB)

    Linker, J. A.; Caplan, R. M.; Downs, C.; Riley, P.; Mikic, Z.; Lionello, R. [Predictive Science Inc., 9990 Mesa Rim Road, Suite 170, San Diego, CA 92121 (United States); Henney, C. J. [Air Force Research Lab/Space Vehicles Directorate, 3550 Aberdeen Avenue SE, Kirtland AFB, NM (United States); Arge, C. N. [Science and Exploration Directorate, NASA/GSFC, Greenbelt, MD 20771 (United States); Liu, Y. [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 (United States); Derosa, M. L. [Lockheed Martin Solar and Astrophysics Laboratory, 3251 Hanover Street B/252, Palo Alto, CA 94304 (United States); Yeates, A. [Department of Mathematical Sciences, Durham University, Durham, DH1 3LE (United Kingdom); Owens, M. J., E-mail: linkerj@predsci.com [Space and Atmospheric Electricity Group, Department of Meteorology, University of Reading, Earley Gate, P.O. Box 243, Reading RG6 6BB (United Kingdom)

    2017-10-10

    The heliospheric magnetic field is of pivotal importance in solar and space physics. The field is rooted in the Sun’s photosphere, where it has been observed for many years. Global maps of the solar magnetic field based on full-disk magnetograms are commonly used as boundary conditions for coronal and solar wind models. Two primary observational constraints on the models are (1) the open field regions in the model should approximately correspond to coronal holes (CHs) observed in emission and (2) the magnitude of the open magnetic flux in the model should match that inferred from in situ spacecraft measurements. In this study, we calculate both magnetohydrodynamic and potential field source surface solutions using 14 different magnetic maps produced from five different types of observatory magnetograms, for the time period surrounding 2010 July. We have found that for all of the model/map combinations, models that have CH areas close to observations underestimate the interplanetary magnetic flux, or, conversely, for models to match the interplanetary flux, the modeled open field regions are larger than CHs observed in EUV emission. In an alternative approach, we estimate the open magnetic flux entirely from solar observations by combining automatically detected CHs for Carrington rotation 2098 with observatory synoptic magnetic maps. This approach also underestimates the interplanetary magnetic flux. Our results imply that either typical observatory maps underestimate the Sun’s magnetic flux, or a significant portion of the open magnetic flux is not rooted in regions that are obviously dark in EUV and X-ray emission.

  13. [Effect of previous experience in reacting to a danger signal on "open field" behavior in the rat].

    Science.gov (United States)

    Poltyreva, T E; Petrov, E S

    1983-01-01

    Modification of rats behaviour in an "hopen field" test was investigated, induced by an acoustic stimulus, previously subjected to conditioning in a shuttle chamber in experiments with possibility and impossibility of avoidance from electrical shock. It has been established that presentation of a stimulus having the meaning of a danger signal, in a new situation, significantly suppresses investigating behaviour of rats, whereas the stimulus which had not been subjected to conditioning exerts no marked effect on behaviour. The greatest suppression was observed in rats with "learned helplessness". This fact suggests that the degree of suppression of the behaviour in an open field in response to a danger signal, depends on the animal's previous experience in reacting to this signal.

  14. An Alternative Interpretation of the Relationship between the Inferred Open Solar Flux and the Interplanetary Magnetic Field

    Science.gov (United States)

    Riley, Pete

    2007-01-01

    Photospheric observations at the Wilcox Solar Observatory (WSO) represent an uninterrupted data set of 32 years and are therefore unique for modeling variations in the magnetic structure of the corona and inner heliosphere over three solar cycles. For many years, modelers have applied a latitudinal correction factor to these data, believing that it provided a better estimate of the line-of-sight magnetic field. Its application was defended by arguing that the computed open flux matched observations of the interplanetary magnetic field (IMF) significantly better than the original WSO correction factor. However, no physically based argument could be made for its use. In this Letter we explore the implications of using the constant correction factor on the value and variation of the computed open solar flux and its relationship to the measured IMF. We find that it does not match the measured IMF at 1 AU except at and surrounding solar minimum. However, we argue that interplanetary coronal mass ejections (ICMEs) may provide sufficient additional magnetic flux to the extent that a remarkably good match is found between the sum of the computed open flux and inferred ICME flux and the measured flux at 1 AU. If further substantiated, the implications of this interpretation may be significant, including a better understanding of the structure and strength of the coronal field and I N providing constraints for theories of field line transport in the corona, the modulation of galactic cosmic rays, and even possibly terrestrial climate effects.

  15. Confinement of plasma along shaped open magnetic fields from the centrifugal force of supersonic plasma rotation.

    Science.gov (United States)

    Teodorescu, C; Young, W C; Swan, G W S; Ellis, R F; Hassam, A B; Romero-Talamas, C A

    2010-08-20

    Interferometric density measurements in plasmas rotating in shaped, open magnetic fields demonstrate strong confinement of plasma parallel to the magnetic field, with density drops of more than a factor of 10. Taken together with spectroscopic measurements of supersonic E × B rotation of sonic Mach 2, these measurements are in agreement with ideal MHD theory which predicts large parallel pressure drops balanced by centrifugal forces in supersonically rotating plasmas.

  16. Current density waves in open mesoscopic rings driven by time-periodic magnetic fluxes

    International Nuclear Information System (INIS)

    Yan Conghua; Wei Lianfu

    2010-01-01

    Quantum coherent transport through open mesoscopic Aharonov-Bohm rings (driven by static fluxes) have been studied extensively. Here, by using quantum waveguide theory and the Floquet theorem we investigate the quantum transport of electrons along an open mesoscopic ring threaded by a time-periodic magnetic flux. We predicate that current density waves could be excited along such an open ring. As a consequence, a net current could be generated along the lead with only one reservoir, if the lead additionally connects to such a normal-metal loop driven by the time-dependent flux. These phenomena could be explained by photon-assisted processes, due to the interaction between the transported electrons and the applied oscillating external fields. We also discuss how the time-average currents (along the ring and the lead) depend on the amplitude and frequency of the applied oscillating fluxes.

  17. Effect of magnetization boundary condition on cavity magnon polariton of YIG thin film

    Science.gov (United States)

    Jiang, H. H.; Xiao, Y.; Hu, C. M.; Guo, H.; Xia, K.

    2018-06-01

    Motivated by recent studies of cavity magnon polariton (CMP), we extended a previous theoretical work to generalize microwave transmission calculation with various magnetization boundary condition of YIG thin film embedded in cavity. It is found that numerical implementation given in this paper can be easily applied to other magnetization boundary condition and extended to magnetic multilayers. Numerical results show that ferromagnetic resonance mode of microwave transmission spectrum, which is absent in previous calculation, can be recovered by altering the pinning condition of surface spins. The demonstrated reliability of our theory opens attractive perspectives for studying CMP of thin film with complicated surface magnetization distribution and magnetic multilayers.

  18. Can Polar Fields Explain Missing Open Flux?

    Science.gov (United States)

    Linker, J.; Downs, C.; Caplan, R. M.; Riley, P.; Mikic, Z.; Lionello, R.

    2017-12-01

    The "open" magnetic field is the portion of the Sun's magnetic field that extends out into the heliosphere and becomes the interplanetary magnetic field (IMF). Both the IMF and the Sun's magnetic field in the photosphere have been measured for many years. In the standard paradigm of coronal structure, the open magnetic field originates primarily in coronal holes. The regions that are magnetically closed trap the coronal plasma and give rise to the streamer belt. This basic picture is qualitatively reproduced by models of coronal structure using photospheric magnetic fields as input. If this paradigm is correct, there are two primary observational constraints on the models: (1) The open field regions in the model should approximately correspond to coronal holes observed in emission, and (2) the magnitude of the open magnetic flux in the model should match that inferred from in situ spacecraft measurements. Linker et al. (2017, ApJ, submitted) investigated the July 2010 time period for a range of observatory maps and both PFSS and MHD models. We found that all of the model/map combinations underestimated the interplanetary magnetic flux, unless the modeled open field regions were larger than observed coronal holes. An estimate of the open magnetic flux made entirely from solar observations (combining detected coronal hole boundaries with observatory synoptic magnetic maps) also underestimated the interplanetary magnetic flux. The magnetic field near the Sun's poles is poorly observed and may not be well represented in observatory maps. In this paper, we explore whether an underestimate of the polar magnetic flux during this time period could account for the overall underestimate of open magnetic flux. Research supported by NASA, AFOSR, and NSF.

  19. Dynamics of the plasma injected into the gap of a plasma opening switch across a strong magnetic field

    International Nuclear Information System (INIS)

    Dolgachev, G. I.; Maslennikov, D. D.; Ushakov, A. G.; Fedotkin, A. S.; Khodeev, I. A.; Shvedov, A. A.

    2011-01-01

    A method is proposed to increase the linear charge density transferred through a plasma opening switch (POS) and, accordingly, reduce the POS diameter by enhancing the external magnetic field in the POS gap. Results are presented from experimental studies of the dynamics of the plasma injected into the POS gap across a strong magnetic field. The possibility of closing the POS gap by the plasma injected across an external magnetic field of up to 60 kG is demonstrated.

  20. An achromatic multipassage magnetic mass spectrometer

    International Nuclear Information System (INIS)

    Boulanger, P.; Baril, M.

    1999-01-01

    A design providing achromatic correction to a multipassage magnetic mass spectrometer previously described by the author is presented. The energy spatial dispersion caused by repeated passages in the magnetic prism is corrected by three supplementary mirrors placed in a reinjection loop. From this study one can see that we simultaneously eliminate the energy dispersion term C ΔE/E and the opening angle aberration term C α 2 and we may also eliminate the coupled aberration term C αΔE/E

  1. Gap opening and tuning in single-layer graphene with combined electric and magnetic field modulation

    Institute of Scientific and Technical Information of China (English)

    Lin Xin; Wang Hai-Long; Pan Hui; Xu Huai-Zhe

    2011-01-01

    The energy band structure of single-layer graphene under one-dimensional electric and magnetic field modulation is theoretically investigated. The criterion for bandgap opening at the Dirac point is analytically derived with a two-fold degeneracy second-order perturbation method. It is shown that a direct or an indirect bandgap semiconductor could be realized in a single-layer graphene under some specific configurations of the electric and magnetic field arrangement. Due to the bandgap generated in the single-layer graphene, the Klein tunneling observed in pristine graphene is completely suppressed.

  2. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  3. Eddy current loss analysis of open-slot fault-tolerant permanent-magnet machines based on conformal mapping method

    Science.gov (United States)

    Ji, Jinghua; Luo, Jianhua; Lei, Qian; Bian, Fangfang

    2017-05-01

    This paper proposed an analytical method, based on conformal mapping (CM) method, for the accurate evaluation of magnetic field and eddy current (EC) loss in fault-tolerant permanent-magnet (FTPM) machines. The aim of modulation function, applied in CM method, is to change the open-slot structure into fully closed-slot structure, whose air-gap flux density is easy to calculate analytically. Therefore, with the help of Matlab Schwarz-Christoffel (SC) Toolbox, both the magnetic flux density and EC density of FTPM machine are obtained accurately. Finally, time-stepped transient finite-element method (FEM) is used to verify the theoretical analysis, showing that the proposed method is able to predict the magnetic flux density and EC loss precisely.

  4. Temperature mapping using proton phase shift on a 0.3 T permanent magnet open MRI system

    International Nuclear Information System (INIS)

    Komura, Kazumi; Takahashi, Tetsuhiko; Dohi, Michiko; Harada, Junta

    2000-01-01

    Temperature mapping using proton phase shift (PPS) was evaluated for ex vivo objects. The evaluation was done on a 0.3 T permanent magnet open magnetic resonance imaging (MRI) machine, like those widely used for clinical diagnosis. Temperature maps were acquired using a gradient echo sequence (TR/TE =80/30 ms, flip angle =60 degrees, field of view =200 x 200 mm, slice thickness =8 mm, matrix size =128 x 128, data acquisition number =1, and imaging time =10.2 s). Specific first order data correction was performed to eliminate calculated temperature fluctuation due to magnetic field instability. A ham, 10 cm in diameter, was heated with a Nd: YAG laser with a wavelength of 1064 nm. The laser fiber was inserted into the ham to a depth of 3 cm. The laser power was 5, 8, or 10 W. Magnetic resonance images were taken continually during and after irradiation. Temperature maps were taken every 15 s. The maps taken during laser ablation showed color changes for the heated areas. Temperatures measured by the MRI and thermocouple had a linear relationship of r 2 =0.80. The inter-image standard deviation of the temperature maps of a non-heated object was 2.07 degrees for a 4.68 x 4.68 x 8 mm volume. This value is negligible for a monitored laser heating process since temperature rise is typically larger than 30 degrees. These results show that temperature mapping based on PPS is feasible for a 0.3 T permanent magnet open MRI system. (author)

  5. Low mass planets in protoplanetary disks with net vertical magnetic fields: the Planetary Wake and Gap Opening

    OpenAIRE

    Zhu, Zhaohuan; Stone, James M.; Rafikov, Roman R.

    2013-01-01

    We study wakes and gap opening by low mass planets in gaseous protoplanetary disks threaded by net vertical magnetic fields which drive magnetohydrodynamical (MHD) turbulence through the magnetorotational instabilty (MRI), using three dimensional simulations in the unstratified local shearing box approximation. The wakes, which are excited by the planets, are damped by shocks similar to the wake damping in inviscid hydrodynamic (HD) disks. Angular momentum deposition by shock damping opens ga...

  6. The technique of MRT aided abdominal drainage using an open low field magnet. Feasibility and first results

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.; Schimmelpenning, H.; Weiss, H.D.

    1996-01-01

    To test the practicality of MRT-aided drainage using an open low field magnet and to report on the early clinical results. So far seven patients have been treated (four subphrenic abscesses, two psoas abscesses and one pancreatic pseudocyst). The planning of the approach and catheter insertion were carried out under MRT control (Magnetom Open, 0.2 T). Subsequent treatment was controlled by CT and fluoroscopy. Initial puncture was carried out with a non-magnetic 18 gauge Chiba needle. The drainage catheter was introduced by Seldinger's technique in six cases and with a trocar in one patient. In all seven patients drainage could be started successfully. The design of the magnet and coils permitted adequate accessibility of the patient. There were no problems in visualising the puncture needle. Controlling the position of the catheter by MRT was, however, difficult. The first two steps in abscess drainage (planning the approach and inserting the catheter) can be carried out under MRT control. For further catheter control and observing the course of the disease we presently prefer CT or fluoroscopy. (orig.) [de

  7. The Role of Low-frequency TRANS-orbital Magnetic Stimulation in Normalization of Intraocular Pressure in Patients with Primary Open-angle Glaucoma

    Directory of Open Access Journals (Sweden)

    I. A. Makarov

    2016-01-01

    Full Text Available Purpose. Assessment of the effectiveness of low-frequency magnetic therapy on the dynamics of intraocular pressure in the treatment of primary and uncompensated medical means of open-angle glaucoma. Patients and Methods. 46 patients with uncompensated open-angle glaucoma. The first group: 24 patients (42 eyes with open-angle glaucoma (I, II, III stages during 2–13 years. The second group: 22 patients (22 eyes with newly diagnosed elevated intraocular pressure in one eye. The age of patients ranged from 43 to 59 years. Treatment included antiglaucoma hypotensive eye drops and TRANS-orbital magnetic stimulation on the domestic device“Polus-2”. Results. Intraocular pressure before treatment ranged from 25 to 32 mm Hg. (average of 28.9±1.4 mm Hg. in the first group . After magnetic stimulation IOP decreased within 2–5 days in all patients to 18 to 21 mm Hg (average of 17.9±1.1 mm Hg, reaching values “pressure goal.” Second group: in the primary treatment in patients IOP was 28–39 mm Hg (average of 32.6±1.8 mm Hg on one of the eyes. IOP decreased to 16–21 mm Hg in the period from 3 to 9 days in all patients of study group after daily magnetic stimulation and instillation of xalatan and timolol. In the control subgroup of patients with uncompensated openangle glaucoma loweringof the IOP to “pressure goal,” noted only in 7 patients (70,0% 11–14 days after instillation of anti-hypertensive glaucoma eye drops only. Conclusion. Low-frequency TRANS-orbital magnetic stimulation in enhanced hypotensive effect antiglaucomatous eye drops and makes it easier to achieve compensation of IOP to values “pressure goals” in patients with uncompensated open-angle glaucoma. The marked dependence of the efficiency of reduction of IOP from biotropic parameters of the magnetic field. The pulsed mode with a higher amplitude value of the magnetic induction has a more pronounced effect and makes it easier to achieve the reduction of IOP.

  8. Optical magnetism in planar metamaterial heterostructures.

    Science.gov (United States)

    Papadakis, Georgia T; Fleischman, Dagny; Davoyan, Artur; Yeh, Pochi; Atwater, Harry A

    2018-01-18

    Harnessing artificial optical magnetism has previously required complex two- and three-dimensional structures, such as nanoparticle arrays and split-ring metamaterials. By contrast, planar structures, and in particular dielectric/metal multilayer metamaterials, have been generally considered non-magnetic. Although the hyperbolic and plasmonic properties of these systems have been extensively investigated, their assumed non-magnetic response limits their performance to transverse magnetic (TM) polarization. We propose and experimentally validate a mechanism for artificial magnetism in planar multilayer metamaterials. We also demonstrate that the magnetic properties of high-index dielectric/metal hyperbolic metamaterials can be anisotropic, leading to magnetic hyperbolic dispersion in certain frequency regimes. We show that such systems can support transverse electric polarized interface-bound waves, analogous to their TM counterparts, surface plasmon polaritons. Our results open a route for tailoring optical artificial magnetism in lithography-free layered systems and enable us to generalize the plasmonic and hyperbolic properties to encompass both linear polarizations.

  9. Research of influence of open-winding faults on properties of brushless permanent magnets motor

    Science.gov (United States)

    Bogusz, Piotr; Korkosz, Mariusz; Powrózek, Adam; Prokop, Jan; Wygonik, Piotr

    2017-12-01

    The paper presents an analysis of influence of selected fault states on properties of brushless DC motor with permanent magnets. The subject of study was a BLDC motor designed by the authors for unmanned aerial vehicle hybrid drive. Four parallel branches per each phase were provided in the discussed 3-phase motor. After open-winding fault in single or few parallel branches, a further operation of the motor can be continued. Waveforms of currents, voltages and electromagnetic torque were determined in discussed fault states based on the developed mathematical and simulation models. Laboratory test results concerning an influence of open-windings faults in parallel branches on properties of BLDC motor were presented.

  10. Research of influence of open-winding faults on properties of brushless permanent magnets motor

    Directory of Open Access Journals (Sweden)

    Bogusz Piotr

    2017-12-01

    Full Text Available The paper presents an analysis of influence of selected fault states on properties of brushless DC motor with permanent magnets. The subject of study was a BLDC motor designed by the authors for unmanned aerial vehicle hybrid drive. Four parallel branches per each phase were provided in the discussed 3-phase motor. After open-winding fault in single or few parallel branches, a further operation of the motor can be continued. Waveforms of currents, voltages and electromagnetic torque were determined in discussed fault states based on the developed mathematical and simulation models. Laboratory test results concerning an influence of open-windings faults in parallel branches on properties of BLDC motor were presented.

  11. [Laparoscopic and general surgery guided by open interventional magnetic resonance].

    Science.gov (United States)

    Lauro, A; Gould, S W T; Cirocchi, R; Giustozzi, G; Darzi, A

    2004-10-01

    Interventional magnetic resonance (IMR) machines have produced unique opportunity for image-guided surgery. The open configuration design and fast pulse sequence allow virtual real time intraoperative scanning to monitor the progress of a procedure, with new images produced every 1.5 sec. This may give greater appreciation of anatomy, especially deep to the 2-dimensional laparoscopic image, and hence increase safety, reduce procedure magnitude and increase confidence in tumour resection surgery. The aim of this paper was to investigate the feasibility of performing IMR-image-guided general surgery, especially in neoplastic and laparoscopic field, reporting a single center -- St. Mary's Hospital (London, UK) -- experience. Procedures were carried out in a Signa 0.5 T General Elettric SP10 Interventional MR (General Electric Medical Systems, Milwaukee, WI, USA) with magnet-compatible instruments (titanium alloy instruments, plastic retractors and ultrasonic driven scalpel) and under general anesthesia. There were performed 10 excision biopsies of palpable benign breast tumors (on female patients), 3 excisions of skin sarcoma (dermatofibrosarcoma protuberans), 1 right hemicolectomy and 2 laparoscopic cholecystectomies. The breast lesions were localized with pre- and postcontrast (intravenous gadolinium DPTA) sagittal and axial fast multiplanar spoiled gradient recalled conventional Signa sequences; preoperative real time fast gradient recalled sequences were also obtained using the flashpoint tracking device. During right hemicolectomy intraoperative single shot fast spin echo (SSFSE) and fast spoiled gradient recalled (FSPGR) imaging of right colon were performed after installation of 150 cc of water or 1% gadolinium solution, respectively, through a Foley catheter; imaging was also obtained in an attempt to identify mesenteric lymph nodes intraoperatively. Concerning laparoscopic procedures, magnetic devices (insufflator, light source) were positioned outside scan

  12. Induced Voltage in an Open Wire

    Science.gov (United States)

    Morawetz, K.; Gilbert, M.; Trupp, A.

    2017-07-01

    A puzzle arising from Faraday's law has been considered and solved concerning the question which voltage will be induced in an open wire with a time-varying homogeneous magnetic field. In contrast to closed wires where the voltage is determined by the time variance of the magnetic field and the enclosed area, in an open wire we have to integrate the electric field along the wire. It is found that the longitudinal electric field with respect to the wave vector contributes with 1/3 and the transverse field with 2/3 to the induced voltage. In order to find the electric fields the sources of the magnetic fields are necessary to know. The representation of a spatially homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or symmetry line which depend on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to this symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire placed with different angles in the magnetic field. We present exactly solvable models of the Maxwell equations for a symmetry point and for a symmetry line, respectively. The results are applicable to open circuit problems like corrosion and for astrophysical applications.

  13. Parallel transport of long mean-free-path plasma along open magnetic field lines: Parallel heat flux

    International Nuclear Information System (INIS)

    Guo Zehua; Tang Xianzhu

    2012-01-01

    In a long mean-free-path plasma where temperature anisotropy can be sustained, the parallel heat flux has two components with one associated with the parallel thermal energy and the other the perpendicular thermal energy. Due to the large deviation of the distribution function from local Maxwellian in an open field line plasma with low collisionality, the conventional perturbative calculation of the parallel heat flux closure in its local or non-local form is no longer applicable. Here, a non-perturbative calculation is presented for a collisionless plasma in a two-dimensional flux expander bounded by absorbing walls. Specifically, closures of previously unfamiliar form are obtained for ions and electrons, which relate two distinct components of the species parallel heat flux to the lower order fluid moments such as density, parallel flow, parallel and perpendicular temperatures, and the field quantities such as the magnetic field strength and the electrostatic potential. The plasma source and boundary condition at the absorbing wall enter explicitly in the closure calculation. Although the closure calculation does not take into account wave-particle interactions, the results based on passing orbits from steady-state collisionless drift-kinetic equation show remarkable agreement with fully kinetic-Maxwell simulations. As an example of the physical implications of the theory, the parallel heat flux closures are found to predict a surprising observation in the kinetic-Maxwell simulation of the 2D magnetic flux expander problem, where the parallel heat flux of the parallel thermal energy flows from low to high parallel temperature region.

  14. MAXIMIZING MAGNETIC ENERGY STORAGE IN THE SOLAR CORONA

    International Nuclear Information System (INIS)

    Wolfson, Richard; Drake, Christina; Kennedy, Max

    2012-01-01

    The energy that drives solar eruptive events such as coronal mass ejections (CMEs) almost certainly originates in coronal magnetic fields. Such energy may build up gradually on timescales of days or longer before its sudden release in an eruptive event, and the presence of free magnetic energy capable of rapid release requires nonpotential magnetic fields and associated electric currents. For magnetic energy to power a CME, that energy must be sufficient to open the magnetic field to interplanetary space, to lift the ejecta against solar gravity, and to accelerate the material to speeds of typically several hundred km s –1 . Although CMEs are large-scale structures, many originate from relatively compact active regions on the solar surface—suggesting that magnetic energy storage may be enhanced when it takes place in smaller magnetic structures. This paper builds on our earlier work exploring energy storage in large-scale dipolar and related bipolar magnetic fields. Here we consider two additional cases: quadrupolar fields and concentrated magnetic bipoles intended to simulate active regions. Our models yield stored energies whose excess over that of the corresponding open field state can be greater than 100% of the associated potential field energy; this contrasts with maximum excess energies of only about 20% for dipolar and symmetric bipolar configurations. As in our previous work, energy storage is enhanced when we surround a nonpotential field with a strong overlying potential field that acts to 'hold down' the nonpotential flux as its magnetic energy increases.

  15. Superconducting open-gradient magnetic separation for the pretreatment of radioactive or mixed waste vitrification feeds. 1998 annual progress report

    International Nuclear Information System (INIS)

    Crawford, C.; Doctor, R.D.; Landsberger, S.; Nunez, L.; Ritter, J.

    1998-01-01

    'The objective is to reduce the volume and cost of high-level waste glass produced during US DOE remediation activities by demonstrating that magnetic separation can separate crystalline, amorphous, and colloidal constituents in vitrification feed streams known to be deleterious to the production of borosilicate glass. Magnetic separation will add neither chemicals nor generate secondary waste streams. The project includes the systematic study of magnetic interactions of waste constituents under controlled physical and chemical conditions (e.g., hydration, oxidation, temperature) to identify mechanisms that control the magnetic properties. Partitioning of radionuclides to determine their sorption mechanisms is also being studied. The identification of fundamental magnetic properties within the microscopic chemical environment in combination with hydrodynamic and electrodynamic models provides insights into the design of a system for optimal separation. Following this, experimental studies using superconducting open-gradient magnetic separation (OGMS) will be conducted to validate its effectiveness as a pretreatment technique.'

  16. Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    Science.gov (United States)

    Tieng, Quang M; Vegh, Viktor; Brereton, Ian M

    2010-01-01

    The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut configuration. This extends the work to multiple magnet domain configurations. The use of double-doughnut magnets in MRI scanners has previously been hindered by the ability to deliver strong magnetic fields over a sufficiently large volume appropriate for imaging, essentially limiting spatial resolution, signal-to-noise ratio, and field of view. The requirement of dedicated interventional space restricts the manner in which the coils can be arranged and placed. The minimum stored energy optimal coil arrangement ensures that the field strength is maximized over a specific region of imaging. The design method yields open, dual-domain magnets capable of delivering greater field strengths than those used prior to this work, and at the same time it provides an increase in the field-of-view volume. Simulation results are provided for 1-T double-doughnut magnets with at least a 50-cm 1-ppm (parts per million) field of view and 0.7-m gap between the two doughnuts. Copyright (c) 2009 Wiley-Liss, Inc.

  17. Static and dynamic evaluation of pelvic floor disorders with an open low-field tilting magnet

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Pastorelli, D.; Squillaci, E.; Funel, V.; Rascioni, M.; Meschini, A.; Salimbeni, C.; Sileri, P.; Franceschilli, L.; Simonetti, G.

    2013-01-01

    Aim: To assess the feasibility of magnetic resonance defaecography (MRD) in pelvic floor disorders using an open tilting magnet with a 0.25 T static field and to compare the results obtained from the same patient both in supine and orthostatic positions. Materials and methods: From May 2010 to November 2011, 49 symptomatic female subjects (mean age 43.5 years) were enrolled. All the patients underwent MRD in the supine and orthostatic positions using three-dimensional (3D) hybrid contrast-enhanced (HYCE) sequences and dynamic gradient echo (GE) T1-weighted sequences. All the patients underwent conventional defaecography (CD) to correlate both results. Two radiologists evaluated the examinations; inter and intra-observer concordance was measured. The results obtained in the two positions were compared between them and with CD. Results: The comparison between CD and MRD found statistically significant differences in the evaluation of anterior and posterior rectocoele during defaecation in both positions and of rectal prolapse under the pubo-coccygeal line (PCL) during evacuation, only in the supine position (versus MRD orthostatic: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.008; versus CD: rectal prolapse p < 0.0001; anterior rectocoele p < 0.001; posterior rectocoele p = 0.01). The value of intra-observer intra-class correlation coefficient (ICC) ranged from good to excellent; the interobserver ICC from moderate to excellent. Conclusion: MRD is feasible with an open low-field tilting magnet, and it is more accurate in the orthostatic position than in the supine position to evaluate pelvic floor disorders

  18. Si-Imidazole-HSO4 Functionalized Magnetic Fe3O4 Nanoparticles as an Efficient and Reusable Catalyst for the Regioselective Ring Opening of Epoxides in Water

    Directory of Open Access Journals (Sweden)

    Eshagh Rezaee Nezhad

    2016-01-01

    Full Text Available An efficient and simple method for the preparation of Si-Imidazole-HSO4 functionalized magnetic Fe3O4 nanoparticles (Si-Im-HSO4 MNPs and used as an efficient and reusable magnetic catalysts for the regioselective ring opening of epoxides under green conditions in water. This catalyst was used for the ring opening of epoxide corresponding to the thiocyanohydrins and azidohydrines. Compared to the classical ring opening of epoxides, this new method consistently has the advantage of excellent yields, short reaction times, and methodological simplicity.

  19. Magnetizing of permanent magnet using HTS bulk magnet

    International Nuclear Information System (INIS)

    Oka, Tetsuo; Muraya, Tomoki; Kawasaki, Nobutaka; Fukui, Satoshi; Ogawa, Jun; Sato, Takao; Terasawa, Toshihisa

    2011-01-01

    A demagnetized Nd-Fe-B permanent magnet was scanned just above the magnetic pole containing the HTS bulk magnet, generating a magnetic field of 3.27 T. The magnet sample was subsequently found to be fully magnetized in the open space of the static magnetic fields. We examined the magnetic field distributions when the magnetic poles were scanned twice to activate the magnetic plates inversely with various overlap distances between the tracks of the HTS bulk magnet. The magnetic field of the 'rewritten' magnet reached the values of the magnetically saturated region of the material, showing steep gradients at the border of each magnetic pole. As a replacement for conventional pulse field magnetizing methods, this technique is proposed to expand the degree of freedom in the design of electromagnetic devices, and is proposed as a novel practical method for magnetizing rare-earth magnets, which have excellent magnetic performance and require intense fields of more than 3 T to be activated. (author)

  20. Structural and magnetic characterization of three tetranuclear Cu(II) complexes with face-sharing-dicubane/double-open-cubane like core framework

    International Nuclear Information System (INIS)

    Paul, Aparup; Bertolasi, Valerio; Figuerola, Albert; Manna, Subal Chandra

    2017-01-01

    Three novel tetranuclear copper(II) complexes namely [Cu 4 (L 1 ) 4 ]∙2(dmf) (1), [Cu 4 (L 1 ) 4 ] (2) and [Cu 4 (L 2 ) 2 (HL 2 ) 2 (H 2 O) 2 ]∙2(ClO 4 )·6(H 2 O) (3) (H 2 L 1 , (E)−2-((1-hydroxybutan-2-ylimino)methyl)phenol; H 2 L 2 , (E)−2-((1-hydroxybutan-2-ylimino)methyl)−6-methoxyphenol)) were synthesized from the self-assembly of copper(II) perchlorate and the tridentate Schiff base ligands. The structural determination reveals that crystallizes in the monoclinic system with space group C2/c, whereas both the and crystallize in the triclinic system with space group P-1. and possess face-sharing dicubane core, on the other hand complex 3 has double open cubane core structure. The copper(II) ions in the cubane core are in distorted square planar geometries, and weak π…π and C–H…π interactions lead to formation of a 2D supramolecular architecture for and . At room temperature and , exhibit fluorescence with a quantum yield (Φ s ) of 0.47, 0.49 and 0.38, respectively. Variable temperature magnetic susceptibility measurements in the range 2–300 K indicate an overall weak antiferromagnetic exchange coupling in all complexes. The PHI program was used to study their magnetic behaviour. In agreement with their face-sharing dicubane structure, a Hamiltonian of the type H =– J 1 (S 1 S 2 +S 1 S 2’ +S 1' S 2 +S 1' S 2’ ) – J 2 S 1 S 1’ , where S 1 = S 1’ = S 2 = S 2’ = S Cu =1/2, was used for studying and . Simulations performed suggest magnetic exchange constants with values close to J 1 =−20 cm −1 and J 2 =0 cm -1 for these complexes. On the other hand, the spin Hamiltonian H =– J 1 (S 1 S 4 +S 2 S 3 ) – J 2 (S 1 S 3 +S 2 S 4 ) – J 3 S 1 S 2 , where S 1 = S 2 = S 3 = S 4 = S Cu =1/2, was used to study the magnetic behaviour of the double open cubane core of and a good agreement between the experimental and simulated results was found by using the parameters g 1 = g 2 =2.20, g 3 = g 4 =2.18, J 1 =−36 cm -1 , J 2

  1. Psychological evaluation of patients undergoing MR imaging: analysis, proposals for improvement and place of open magnet systems

    International Nuclear Information System (INIS)

    Tillier, Ph.; Leclet, H.; Laplanche, T.; Madoux, M.; Picoult, C.; Delvalle, A.; Delforge, P.M.; Malgouyres, A.

    1997-01-01

    Many patients report anxiety during MR imaging. Anxiety is due to immobility, coil noise, high temperature, duration of the examination and shape of the system. On basis of a prospective series of 250 patients undergoing MR studies, we have analysed mechanisms and reasons of anxiety. Psychological strategies are useful to reduce anxiety and improve patients' cooperation and relaxation. The easiest and most effective way is to inform the distressed patient. Information about the MRI examination must be clear and simple. Open field magnets improve comfort and global conditions of the examination realisation. Psychological consequences are less important. Open field MR systems reduce claustrophobia induced by MR imaging. (author)

  2. All-in-One Magnetic Resonance Arthrography of the Shoulder in a Vertically Open Magnetic Resonance Unit

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, J.E.; Vanhoenacker, F.; Beaulieu, C.F.; Bergman, A.; Butts Pauly, K.; Dillingham, M.F.; Lang, P.K. (Dept. of Radiology, Univ. Hospital Antwerp, Edegem-Antwerp (Belgium))

    2008-10-15

    Background: Magnetic resonance (MR) arthrography frequently involves joint injection under imaging guidance followed by MR imaging in static positions. Purpose: To evaluate if MR arthrography of the shoulder joint can be performed in a comprehensive fashion combining the MR-guided injection procedure, static MR imaging, and dynamic motion MR imaging in a single test. Material and Methods: Twenty-three shoulder joints were injected with Gd-DTPA2- under MR guidance. Static MR imaging was performed and included a three-point Dixon method to achieve water-selective images. Dynamic motion MR imaging with and without applying pressure to the upper arm was used to evaluate glenohumeral joint instability. In 10 cases, surgical correlation was available. Results: The all-in-one MR arthrography technique was successful in all patients, and took an average time of 65 min. All but one glenohumeral injection procedure were performed with a single needle pass, and no complications were observed. Out of eight labrum tears seen with static MR imaging, seven were confirmed at surgery. In 10 cases, dynamic motion MR imaging correlated well with the surgeon's intraoperative evaluation for presence and direction of instability. Conclusion: MR arthrography of the shoulder joint using a vertically open magnet can be performed as a single comprehensive test, including the injection and the static and dynamic motion MR imaging. Good diagnostic accuracy for intraarticular lesions and glenohumeral instability was found in a small sample.

  3. A numerical model for aggregations formation and magnetic driving of spherical particles based on OpenFOAM®.

    Science.gov (United States)

    Karvelas, E G; Lampropoulos, N K; Sarris, I E

    2017-04-01

    This work presents a numerical model for the formation of particle aggregations under the influence of a permanent constant magnetic field and their driving process under a gradient magnetic field, suitably created by a Magnetic Resonance Imaging (MRI) device. The model is developed in the OpenFOAM platform and it is successfully compared to the existing experimental and numerical results in terms of aggregates size and their motion in water solutions. Furthermore, several series of simulations are performed for two common types of particles of different diameter in order to verify their aggregation and flow behaviour, under various constant and gradient magnetic fields in the usual MRI working range. Moreover, the numerical model is used to measure the mean length of aggregations, the total time needed to form and their mean velocity under different permanent and gradient magnetic fields. The present model is found to predict successfully the size, velocity and distribution of aggregates. In addition, our simulations showed that the mean length of aggregations is proportional to the permanent magnetic field magnitude and particle diameter according to the relation : l¯ a =7.5B 0 d i 3/2 . The mean velocity of the aggregations is proportional to the magnetic gradient, according to : u¯ a =6.63G˜B 0 and seems to reach a steady condition after a certain period of time. The mean time needed for particles to aggregate is proportional to permanent magnetic field magnitude, scaled by the relationship : t¯ a ∝7B 0 . A numerical model to predict the motion of magnetic particles for medical application is developed. This model is found suitable to predict the formation of aggregations and their motion under the influence of permanent and gradient magnetic fields, respectively, that are produced by an MRI device. The magnitude of the external constant magnetic field is the most important parameter for the aggregations formation and their driving. Copyright © 2017

  4. Treatment satisfaction with paliperidone extended-release tablets: open-label study in schizophrenia patients dissatisfied with previous antipsychotic medication

    Directory of Open Access Journals (Sweden)

    Yang FD

    2017-04-01

    Full Text Available Fu De Yang,1 Juan Li,1 Yun Long Tan,1 Wei Ye Liang,1 Rongzhen Zhang,1 Ning Wang,1 Wei Feng,1 Shangli Cai,2 Jian Min Zhuo,2 Li Li Zhang2 1Beijing Hui-Long-Guan Hospital, 2Department of Medical Affairs, Xian Janssen Pharmaceutical Ltd, Beijing, People’s Republic of China Objective: The aim of this study was to evaluate the changes in treatment satisfaction after switching to paliperidone extended-release (ER in Chinese schizophrenia patients dissatisfied with their previous antipsychotic treatment.Methods: In this 8-week, open-label, single-arm, multicenter, prospective study, 1,693 patients dissatisfied with previous antipsychotic medication were enrolled and switched to paliperidone ER tablets (3–12 mg/d based on clinical judgment. The primary efficacy end point was change in Medication Satisfaction Questionnaire (MSQ score from baseline to week 8. The secondary end points included percentage of patients with MSQ score ≥4, as well as changes in Clinical Global Improvement-Severity (CGI-S and Personal and Social Performance (PSP scores.Results: MSQ scores increased significantly from baseline (mean [standard deviation {SD}]: 2.48 [0.55] to week 8 (5.47 [0.89], P<0.0001; primary end point, full analysis set. The percentage of patients with MSQ score ≥4 was 95.9% at week 8, indicating that most of the patients were satisfied with their treatment. Significant (P<0.0001 improvements from baseline to week 8 were noted in CGI-S score (2.37 [1.20] and PSP score (25.5 [15.0]. A total of 174 (10.28% patients experienced adverse events (AEs. The most common (>10 patients events were extrapyramidal disorder (n=84, 4.96%, poor quality sleep (n=18, 1.06% and akathisia (n=13, 0.77%. The majority of AEs were mild to moderate in severity. No deaths occurred.Conclusion: Treatment satisfaction improved after switching to paliperidone ER from the previous antipsychotic in Chinese patients with schizophrenia. Keywords: atypical antipsychotics, open label

  5. Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours

    DEFF Research Database (Denmark)

    Kristensen, B.H.; Laursen, F.J.; Logager, V.

    2008-01-01

    Background and purpose: Magnetic resonance (MR) imaging is superior to computed tomography (CT) in radiotherapy of brain tumours. In this study an open low-field MR-simulator is evaluated in order to eliminate the cost of and time spent on additional CT scanning. Materials and methods: Eleven...

  6. Evalutation of efficiency of dynamic laser magnetic stimulation of eye drainage system of patients with open angle glaucomatosis

    Directory of Open Access Journals (Sweden)

    Sidelnikova V.S.

    2014-06-01

    Full Text Available The purpose of the study is to develop a comprehensive treatment aimed at improving uveoscleral outflow in the application of dynamic laser magnetic stimulation of the drainage system of the eye and evaluation of its effectiveness in treating patients with primary open-angle glaucoma (POAG. Material. 106 patients diagnosed POAG I, II, III stages were examined. Group 1 consisted of 62 patients treated with medical therapy and dynamic laser magnetic stimulation of the drainage system of the eye using the "AMO-ATOS-ICL", produced by JSC "TRIMA", Saratov. Group 2 consisted of 64 patients who received only medical therapy. Comprehensive survey including standard eye examination, static perimetry, visual evoked potentials study, the study of intraocular blood flow was conducted to all patients. Analysis of the results of the complex therapeutic effects showed that as the result of treatment 73% of patients had a decrease of intraocular pressure and the ease factor outflow increase. 52% of patients had a decrease in the number and area of relative. 63% of patients had activation of intraocular blood flow. These indices remained stable for three months. Conclusion. The treatment with the technique of dynamic laser magnetic stimulation of the drainage system of the eye of patients with primary open-angle glaucoma leads to lower intraocular pressure, and to the improvement of dopple-rographic and perimetric indications.

  7. Open solar flux estimates from near-Earth measurements of the interplanetary magnetic field: comparison of the first two perihelion passes of the Ulysses spacecraft

    Directory of Open Access Journals (Sweden)

    M. Lockwood

    2004-04-01

    Full Text Available Results from all phases of the orbits of the Ulysses spacecraft have shown that the magnitude of the radial component of the heliospheric field is approximately independent of heliographic latitude. This result allows the use of near-Earth observations to compute the total open flux of the Sun. For example, using satellite observations of the interplanetary magnetic field, the average open solar flux was shown to have risen by 29% between 1963 and 1987 and using the aa geomagnetic index it was found to have doubled during the 20th century. It is therefore important to assess fully the accuracy of the result and to check that it applies to all phases of the solar cycle. The first perihelion pass of the Ulysses spacecraft was close to sunspot minimum, and recent data from the second perihelion pass show that the result also holds at solar maximum. The high level of correlation between the open flux derived from the various methods strongly supports the Ulysses discovery that the radial field component is independent of latitude. We show here that the errors introduced into open solar flux estimates by assuming that the heliospheric field's radial component is independent of latitude are similar for the two passes and are of order 25% for daily values, falling to 5% for averaging timescales of 27 days or greater. We compare here the results of four methods for estimating the open solar flux with results from the first and second perehelion passes by Ulysses. We find that the errors are lowest (1–5% for averages over the entire perehelion passes lasting near 320 days, for near-Earth methods, based on either interplanetary magnetic field observations or the aa geomagnetic activity index. The corresponding errors for the Solanki et al. (2000 model are of the order of 9–15% and for the PFSS method, based on solar magnetograms, are of the order of 13–47%. The model of Solanki et al. is based on the continuity equation of open flux, and uses the

  8. Magnetic Behavior of Sintered NdFeB Magnets on a Long-Term Timescale

    Directory of Open Access Journals (Sweden)

    Minna Haavisto

    2014-01-01

    Full Text Available Stable polarization of permanent magnets over the lifetime of the application is an important aspect in electrical machine design. Specification of the long-term stability of magnet material is difficult, since knowledge of the phenomenon is incomplete. To be able to optimize magnet material selection, the long-term magnetic behavior of the material must also be understood. This study shows that material with a very square JH curve is stable until a certain critical operating temperature is reached. Major losses are detected as the critical temperature is exceeded. Material with a rounder JH curve does not show a well-defined critical temperature, but increasing losses over a large temperature range. The critical temperature of a material is also dependent on the field conditions. Results differ whether the tests are performed in an open or closed magnetic circuit. In open-circuit tests, the opposing field is not homogeneously distributed throughout the volume of the magnet and thus the long-term behavior is different than that in closed-circuit conditions. Open-circuit tests seem to give bigger losses than closed-circuit tests in cases where the permeance coefficient of the open-circuit sample is considered to be the average permeance coefficient, calculated according to the dimensions of the magnet.

  9. Plasma opening switch experiments on the Particle Beam Accelerator II

    International Nuclear Information System (INIS)

    Sweeney, M.A.; McDaniel, D.H.; Mendel, C.W.; Rochau, G.E.; Moore, W.B.S.; Mowrer, G.R.; Simpson, W.W.; Zagar, D.M.; Grasser, T.; McDougal, C.D.

    1989-01-01

    Plasma opening switch (POS) experiments have been done since 1986 on the PBFA-II ion beam accelerator to develop a rugged POS that will open rapidly ( 80%) into a high impedance (> 10 ohm) load. In a recent series of experiments on PBFA II, the authors have developed and tested three different switch designs that use magnetic fields to control and confine the injected plasma. All three configurations couple current efficiently to a 5-ohm electron beam diode. In this experimental series, the PBFA-II Delta Series, more extensive diagnostics were used than in previous switch experiments on PBFA II or on the Blackjack 5 accelerator at Maxwell Laboratories. Data from the experiments with these three switch designs is presented

  10. Coronal and heliospheric magnetic flux circulation and its relation to open solar flux evolution

    Science.gov (United States)

    Lockwood, Mike; Owens, Mathew J.; Imber, Suzanne M.; James, Matthew K.; Bunce, Emma J.; Yeoman, Timothy K.

    2017-06-01

    Solar cycle 24 is notable for three features that can be found in previous cycles but which have been unusually prominent: (1) sunspot activity was considerably greater in the northern/southern hemisphere during the rising/declining phase; (2) accumulation of open solar flux (OSF) during the rising phase was modest, but rapid in the early declining phase; (3) the heliospheric current sheet (HCS) tilt showed large fluctuations. We show that these features had a major influence on the progression of the cycle. All flux emergence causes a rise then a fall in OSF, but only OSF with foot points in opposing hemispheres progresses the solar cycle via the evolution of the polar fields. Emergence in one hemisphere, or symmetric emergence without some form of foot point exchange across the heliographic equator, causes poleward migrating fields of both polarities in one or both (respectively) hemispheres which temporarily enhance OSF but do not advance the polar field cycle. The heliospheric field observed near Mercury and Earth reflects the asymmetries in emergence. Using magnetograms, we find evidence that the poleward magnetic flux transport (of both polarities) is modulated by the HCS tilt, revealing an effect on OSF loss rate. The declining phase rise in OSF was caused by strong emergence in the southern hemisphere with an anomalously low HCS tilt. This implies the recent fall in the southern polar field will be sustained and that the peak OSF has limited implications for the polar field at the next sunspot minimum and hence for the amplitude of cycle 25.type="synopsis">type="main">Plain Language SummaryThere is growing interest in being able to predict the evolution in solar conditions on a better basis than past experience, which is necessarily limited. Two of the key features of the solar magnetic cycle are that the polar fields reverse just after the peak of each sunspot cycle and that the polar field that has accumulated by the time of each sunspot minimum is a good

  11. 3D Printing of Polymer-Bonded Rare-Earth Magnets With a Variable Magnetic Compound Fraction for a Predefined Stray Field.

    Science.gov (United States)

    Huber, Christian; Abert, Claas; Bruckner, Florian; Groenefeld, Martin; Schuschnigg, Stephan; Teliban, Iulian; Vogler, Christoph; Wautischer, Gregor; Windl, Roman; Suess, Dieter

    2017-08-25

    Additive manufacturing of polymer-bonded magnets is a recently developed technique, for single-unit production, and for structures that have been impossible to manufacture previously. Also, new possibilities to create a specific stray field around the magnet are triggered. The current work presents a method to 3D print polymer-bonded magnets with a variable magnetic compound fraction distribution. This means the saturation magnetization can be adjusted during the printing process to obtain a required external field of the manufactured magnets. A low-cost, end-user 3D printer with a mixing extruder is used to mix permanent magnetic filaments with pure polyamide (PA12) filaments. The magnetic filaments are compounded, extruded, and characterized for the printing process. To deduce the quality of the manufactured magnets with a variable magnetic compound fraction, an inverse stray field framework is developed. The effectiveness of the printing process and the simulation method is shown. It can also be used to manufacture magnets that produce a predefined stray field in a given region. This opens new possibilities for magnetic sensor applications. This setup and simulation framework allows the design and manufacturing of polymer-bonded permanent magnets, which are impossible to create with conventional methods.

  12. Open volume defects and magnetic phase transition in Fe{sub 60}Al{sub 40} transition metal aluminide

    Energy Technology Data Exchange (ETDEWEB)

    Liedke, M. O., E-mail: m.liedke@hzdr.de; Anwand, W.; Butterling, M.; Wagner, A. [Institute of Radiation Physics, Helmholtz-Zentrum Dresden - Rossendorf, Bautzner Landstraße 400, 01328 Dresden (Germany); Bali, R.; Cornelius, S.; Potzger, K. [Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden - Rossendorf, Bautzner Landstraße 400, 01328 Dresden (Germany); Trinh, T. T. [Institute of Radiation Physics, Helmholtz-Zentrum Dresden - Rossendorf, Bautzner Landstraße 400, 01328 Dresden (Germany); Technical University Dresden, Helmholtzstr. 10, 01609 Dresden (Germany); Salamon, S.; Walecki, D.; Smekhova, A.; Wende, H. [Faculty of Physics and Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen, Lotharstraße 1, 47048 Duisburg (Germany)

    2015-04-28

    Magnetic phase transition in the Fe{sub 60}Al{sub 40} transition metal aluminide from the ferromagnetic disordered A2-phase to the paramagnetic ordered B2-phase as a function of annealing up to 1000 °C has been investigated by means of magneto-optical and spectroscopy techniques, i.e., Kerr effect, positron annihilation, and Mössbauer spectroscopy. The positron annihilation spectroscopy has been performed in-situ sequentially after each annealing step at the Apparatus for In-situ Defect Analysis that is a unique tool combining positron annihilation spectroscopy with temperature treatment, material evaporation, ion irradiation, and sheet resistance measurement techniques. The overall goal was to investigate the importance of the open volume defects onto the magnetic phase transition. No evidence of variation in the vacancy concentration in matching the magnetic phase transition temperature range (400–600 °C) has been found, whereas higher temperatures showed an increase in the vacancy concentration.

  13. Extra high speed modified Lundell alternator parameters and open/short-circuit characteristics from global 3D-FE magnetic field solutions

    Science.gov (United States)

    Wang, R.; Demerdash, N. A.

    1992-01-01

    The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.

  14. Extra high speed modified Lundell alternator parameters and open/short-circuit characteristics from global 3D-FE magnetic field solutions

    Science.gov (United States)

    Wang, R.; Demerdash, N. A.

    1992-06-01

    The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.

  15. PCNL - a comparative study in nonoperated and in previously operated (open nephrolithotomy/pyelolithotomy patients - a single-surgeon experience

    Directory of Open Access Journals (Sweden)

    Rahul Gupta

    2011-12-01

    Full Text Available PURPOSE: Re-procedure in patients with history of open stone surgery is usually challenging due to the alteration in the retroperitoneal anatomy. The aim of this study was to determine the possible impact of open renal surgery on the efficacy and morbidity of subsequent percutaneous nephrolithotomy (PCNL. MATERIALS AND METHODS: From March 2009 until September 2010, 120 patients underwent PCNL. Of these, 20 patients were excluded (tubeless or bilateral simultaneous PCNL. Of the remaining 100, 55 primary patients were categorized as Group 1 and the remaining (previous open nephrolithotomy as Group 2. Standard preoperative evaluation was carried out prior to intervention, Statistical analysis was performed using SPSS v. 11 with the chi-square test, independent samples t-test, and Mann-Whitney U test. A p-value < 0.05 was taken as statistically significant. RESULTS: Both groups were similar in demographic profile and stone burden. Attempts to access the PCS was less in Group 1 compared to Group 2 (1.2 + 1 2 vs 3 + 1.3 respectively and this was statistically significant (p < 0.04. However, the mean operative time between the two groups was not statistically significant (p = 0.44. Blood transfusion rate was comparable in the two groups (p = 0.24. One patient in Group 2 developed hemothorax following a supra-11th puncture. Remaining complications were comparable in both groups. CONCLUSION: Patients with past history of renal stone surgery may need more attempts to access the pelvicaliceal system and have difficulty in tract dilation secondary to retroperitoneal scarring. But overall morbidity and efficacy is same in both groups.

  16. Magnetic particle separation using controllable magnetic force switches

    International Nuclear Information System (INIS)

    Wei Zunghang; Lee, C.-P.; Lai, M.-F.

    2010-01-01

    Magnetic particle separation is very important in biomedical applications. In this study, a magnetic particle microseparator is proposed that uses micro magnets to produce open/closed magnetic flux for switching on/off the separation. When all magnets are magnetized in the same direction, the magnetic force switch for separation is on; almost all magnetic particles are trapped in the channel side walls and the separation rate can reach 95%. When the magnetization directions of adjacent magnets are opposite, the magnetic force switch for separation is off, and most magnetic particles pass through the microchannel without being trapped. For the separation of multi-sized magnetic particles, the proposed microseparator is numerically demonstrated to have high separation rate.

  17. Dissociation in decision bias mechanism between probabilistic information and previous decision

    Directory of Open Access Journals (Sweden)

    Yoshiyuki eKaneko

    2015-05-01

    Full Text Available Target detection performance is known to be influenced by events in the previous trials. It has not been clear, however, whether this bias effect is due to the previous sensory stimulus, motor response, or decision. Also it remains open whether or not the previous trial effect emerges via the same mechanism as the effect of knowledge about the target probability. In the present study, we asked normal human subjects to make a decision about the presence or absence of a visual target. We presented a pre-cue indicating the target probability before the stimulus, and also a decision-response mapping cue after the stimulus so as to tease apart the effect of decision from that of motor response. We found that the target detection performance was significantly affected by the probability cue in the current trial and also by the decision in the previous trial. While the information about the target probability modulated the decision criteria, the previous decision modulated the sensitivity to target-relevant sensory signals (d-prime. Using functional magnetic resonance imaging, we also found that activation in the left intraparietal sulcus was decreased when the probability cue indicated a high probability of the target. By contrast, activation in the right inferior frontal gyrus was increased when the subjects made a target-present decision in the previous trial, but this change was observed specifically when the target was present in the current trial. Activation in these regions was associated with individual-difference in the decision computation parameters. We argue that the previous decision biases the target detection performance by modulating the processing of target-selective information, and this mechanism is distinct from modulation of decision criteria due to expectation of a target.

  18. Dissociation in decision bias mechanism between probabilistic information and previous decision

    Science.gov (United States)

    Kaneko, Yoshiyuki; Sakai, Katsuyuki

    2015-01-01

    Target detection performance is known to be influenced by events in the previous trials. It has not been clear, however, whether this bias effect is due to the previous sensory stimulus, motor response, or decision. Also it remains open whether or not the previous trial effect emerges via the same mechanism as the effect of knowledge about the target probability. In the present study, we asked normal human subjects to make a decision about the presence or absence of a visual target. We presented a pre-cue indicating the target probability before the stimulus, and also a decision-response mapping cue after the stimulus so as to tease apart the effect of decision from that of motor response. We found that the target detection performance was significantly affected by the probability cue in the current trial and also by the decision in the previous trial. While the information about the target probability modulated the decision criteria, the previous decision modulated the sensitivity to target-relevant sensory signals (d-prime). Using functional magnetic resonance imaging (fMRI), we also found that activation in the left intraparietal sulcus (IPS) was decreased when the probability cue indicated a high probability of the target. By contrast, activation in the right inferior frontal gyrus (IFG) was increased when the subjects made a target-present decision in the previous trial, but this change was observed specifically when the target was present in the current trial. Activation in these regions was associated with individual-difference in the decision computation parameters. We argue that the previous decision biases the target detection performance by modulating the processing of target-selective information, and this mechanism is distinct from modulation of decision criteria due to expectation of a target. PMID:25999844

  19. StimTrack: An open-source software for manual transcranial magnetic stimulation coil positioning.

    Science.gov (United States)

    Ambrosini, Emilia; Ferrante, Simona; van de Ruit, Mark; Biguzzi, Stefano; Colombo, Vera; Monticone, Marco; Ferriero, Giorgio; Pedrocchi, Alessandra; Ferrigno, Giancarlo; Grey, Michael J

    2018-01-01

    During Transcranial Magnetic Stimulation (TMS) experiments researchers often use a neuronavigation system to precisely and accurately maintain coil position and orientation. This study aimed to develop and validate an open-source software for TMS coil navigation. StimTrack uses an optical tracker and an intuitive user interface to facilitate the maintenance of position and orientation of any type of coil within and between sessions. Additionally, online access to navigation data is provided, hereby adding e.g. the ability to start or stop the magnetic stimulator depending on the distance to target or the variation of the orientation angles. StimTrack allows repeatable repositioning of the coil within 0.7mm for translation and 0.9) was obtained on all parameters computed on SR curves acquired using StimTrack. StimTrack showed a target accuracy similar to that of a commercial neuronavigation system (BrainSight, Rogue Research Inc.). Indeed, small differences both in position (∼0.2mm) and orientation (TMS. StimTrack allows researchers to tailor its functionality to their specific needs, providing added value that benefits experimental procedures and improves data quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Oscillations in the open solar magnetic flux with a period of 1.68 years: imprint on galactic cosmic rays and implications for heliospheric shielding

    Directory of Open Access Journals (Sweden)

    A. Rouillard

    2004-12-01

    Full Text Available An understanding of how the heliosphere modulates galactic cosmic ray (GCR fluxes and spectra is important, not only for studies of their origin, acceleration and propagation in our galaxy, but also for predicting their effects (on technology and on the Earth's environment and organisms and for interpreting abundances of cosmogenic isotopes in meteorites and terrestrial reservoirs. In contrast to the early interplanetary measurements, there is growing evidence for a dominant role in GCR shielding of the total open magnetic flux, which emerges from the solar atmosphere and enters the heliosphere. In this paper, we relate a strong 1.68-year oscillation in GCR fluxes to a corresponding oscillation in the open solar magnetic flux and infer cosmic-ray propagation paths confirming the predictions of theories in which drift is important in modulating the cosmic ray flux. Key words. Interplanetary physics (Cosmic rays, Interplanetary magnetic fields

  1. Magnetic correlates in electromagnetic consciousness.

    Science.gov (United States)

    Liboff, A R

    2016-01-01

    We examine the hypothesis that consciousness is a manifestation of the electromagnetic field, finding supportive factors not previously considered. It is not likely that traditional electrophysiological signaling modes can be readily transmitted throughout the brain to properly enable this field because of electric field screening arising from the ubiquitous distribution of high dielectric lipid membranes, a problem that vanishes for low-frequency magnetic fields. Many reports over the last few decades have provided evidence that living tissue is robustly sensitive to ultrasmall (1-100 nT) ELF magnetic fields overlapping the γ-frequency range often associated with awareness. An example taken from animal behavior (coherent bird flocking) lends support to the possibility of a disembodied electromagnetic consciousness. In contrast to quantum consciousness hypotheses, the present approach is open to experimental trial.

  2. Plasma opening switch experiments on supermite

    International Nuclear Information System (INIS)

    Mendel, C.W.; Quintenz, J.P.; Rosenthal, S.E.; Savage, M.E.

    1988-01-01

    Experiments using plasma opening switches with fast field coils and plasmas injected on slow magnetic fields are described. Data showing the measurement of the field penetration into the volume that initially held the plasma fill will be shown. Assuming the plasma is mostly pushed back from the coil, rather than being penetrated by the magnetic field allows the density to be calculated, and gives densities of a few times 10 13 cm -3 for our usual operating range. The data makes it clear that the switch is open well before the initial plasma volume is completely penetrated by the magnetic fields. Additional measurements relating to the magnetic field penetration distance and physical penetration mechanism are presented. Other data presented show a magnetic insulation problem which must be solved before very large voltage multiplication can be accomplished with sufficient switch efficiency

  3. INTERPLANETARY MAGNETIC FLUX DEPLETION DURING PROTRACTED SOLAR MINIMA

    International Nuclear Information System (INIS)

    Connick, David E.; Smith, Charles W.; Schwadron, Nathan A.

    2011-01-01

    We examine near-Earth solar wind observations as assembled within the Omni data set over the past 15 years that constitute the latest solar cycle. We show that the interplanetary magnetic field continues to be depleted at low latitudes throughout the protracted solar minimum reaching levels below previously predicted minima. We obtain a rate of flux removal resulting in magnetic field reduction by 0.5 nT yr -1 at 1 AU when averaged over the years 2005-2009 that reduces to 0.3 nT yr -1 for 2007-2009. We show that the flux removal operates on field lines that follow the nominal Parker spiral orientation predicted for open field lines and are largely unassociated with recent ejecta. We argue that the field line reduction can only be accomplished by ongoing reconnection of nominally open field lines or very old closed field lines and we contend that these two interpretations are observationally equivalent and indistinguishable.

  4. Structural and magnetic characterization of three tetranuclear Cu(II) complexes with face-sharing-dicubane/double-open-cubane like core framework

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Aparup [Department of Chemistry and Chemical Technology, Vidyasagar University, Midnapore 721102, West Bengal (India); Bertolasi, Valerio [Dipartimento di Scienze Chimiche e Farmaceutiche, Centro di Strutturistica Diffrattometrica, Università di Ferrara, Via L. Borsari, 46, 44100 Ferrara (Italy); Figuerola, Albert [Departament de Química Inorgànica i Orgànica (Secció de Química Inorgànica) and Institut de Nanociència i Nanotecnologia (IN2UB), Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Manna, Subal Chandra, E-mail: scmanna@mail.vidyasagar.ac.in [Department of Chemistry and Chemical Technology, Vidyasagar University, Midnapore 721102, West Bengal (India)

    2017-05-15

    Three novel tetranuclear copper(II) complexes namely [Cu{sub 4}(L{sup 1}){sub 4}]∙2(dmf) (1), [Cu{sub 4}(L{sup 1}){sub 4}] (2) and [Cu{sub 4}(L{sup 2}){sub 2}(HL{sup 2}){sub 2}(H{sub 2}O){sub 2}]∙2(ClO{sub 4})·6(H{sub 2}O) (3) (H{sub 2}L{sup 1}, (E)−2-((1-hydroxybutan-2-ylimino)methyl)phenol; H{sub 2}L{sup 2}, (E)−2-((1-hydroxybutan-2-ylimino)methyl)−6-methoxyphenol)) were synthesized from the self-assembly of copper(II) perchlorate and the tridentate Schiff base ligands. The structural determination reveals that crystallizes in the monoclinic system with space group C2/c, whereas both the and crystallize in the triclinic system with space group P-1. and possess face-sharing dicubane core, on the other hand complex 3 has double open cubane core structure. The copper(II) ions in the cubane core are in distorted square planar geometries, and weak π…π and C–H…π interactions lead to formation of a 2D supramolecular architecture for and . At room temperature and , exhibit fluorescence with a quantum yield (Φ{sub s}) of 0.47, 0.49 and 0.38, respectively. Variable temperature magnetic susceptibility measurements in the range 2–300 K indicate an overall weak antiferromagnetic exchange coupling in all complexes. The PHI program was used to study their magnetic behaviour. In agreement with their face-sharing dicubane structure, a Hamiltonian of the type H =– J{sub 1}(S{sub 1}S{sub 2}+S{sub 1}S{sub 2’}+S{sub 1'}S{sub 2}+S{sub 1'}S{sub 2’}) – J{sub 2}S{sub 1}S{sub 1’}, where S{sub 1} = S{sub 1’} = S{sub 2} = S{sub 2’} = S{sub Cu} =1/2, was used for studying and . Simulations performed suggest magnetic exchange constants with values close to J{sub 1} =−20 cm{sup −1} and J{sub 2} =0 cm{sup -1} for these complexes. On the other hand, the spin Hamiltonian H =– J{sub 1}(S{sub 1}S{sub 4}+S{sub 2}S{sub 3}) – J{sub 2}(S{sub 1}S{sub 3}+S{sub 2}S{sub 4}) – J{sub 3}S{sub 1}S{sub 2}, where S{sub 1} = S{sub 2} = S{sub 3} = S{sub 4

  5. The effect of Birkeland currents on magnetic field topology

    Science.gov (United States)

    Peroomian, Vahe; Lyons, Larry R.; Schulz, Michael

    1996-01-01

    A technique was developed for the inclusion of large scale magnetospheric current systems in magnetic field models. The region 1 and 2 Birkeland current systems are included in the source surface model of the terrestrial magnetosphere. The region 1 and 2 Birkeland currents are placed in the model using a series of field aligned, infinitely thin wire segments. The normal component of the magnetic field from these currents is calculated on the surface of the magnetopause and shielded using image current carrying wires placed outside of the magnetosphere. It is found that the inclusion of the Birkeland currents in the model results in a northward magnetic field in the near-midnight tail, leading to the closure of previously open flux in the tail, and a southward magnetic field in the flanks. A sunward shift in the separatrix is observed.

  6. Hamiltonian description of toroidal magnetic fields in vacuum

    International Nuclear Information System (INIS)

    Lewis, H.R.; Bates, J.W.

    1996-01-01

    An investigation of vacuum magnetic fields in toroidal geometry has been initiated. Previously, the general form of the magnetic scalar potential for fields regular at the poloidal axis was given. Here, these results have been expanded to obtain the magnetic scalar potential in a vacuum region that may surround a toroidal current distribution. Using this generalized magnetic scalar potential in conjunction with Boozer's canonical representation of a magnetic field, a field-line Hamiltonian for nonaxisymmetric vacuum fields has been derived. These fields axe being examined using a novel, open-quotes time-dependentclose quotes perturbation theory, which permits the iterative construction of invariants associated with magnetic field-line Hamiltonians that consist of an axisymmetric zeroth-order term, plus a nonaxisymmetric perturbation. By choosing appropriate independent variables, an explicit constructive procedure is developed which involves only a single canonical transformation. Such invariants are of interest because they provide a means of investigating the topology of magnetic field lines. Our objective is to elucidate the existence of magnetic surfaces for nonaxisymmetric vacuum configurations, as well as to provide an approach for studying the onset of stochastic behavior

  7. Opening the cusp. [using magnetic field topology

    Science.gov (United States)

    Crooker, N. U.; Toffoletto, F. R.; Gussenhoven, M. S.

    1991-01-01

    This paper discusses the magnetic field topology (determined by the superposition of dipole, image, and uniform fields) for mapping the cusp to the ionosphere. The model results are compared to both new and published observations and are then used to map the footprint of a flux transfer event caused by a time variation in the merging rate. It is shown that the cusp geometry distorts the field lines mapped from the magnetopause to yield footprints with dawn and dusk protrusions into the region of closed magnetic flux.

  8. Current distribution in a plasma erosion opening switch

    International Nuclear Information System (INIS)

    Weber, B.V.; Commisso, R.J.; Meger, R.A.; Neri, J.M.; Oliphant, W.F.; Ottinger, P.F.

    1984-01-01

    The current distribution in a plasma erosion opening switch is determined from magnetic field probe data. During the closed state of the switch the current channel broadens rapidly. The width of the current channel is consistent with a bipolar current density limit imposed by the ion flux to the cathode. The effective resistivity of the current channel is anomalously large. Current is diverted to the load when a gap opens near the cathode side of the switch. The observed gap opening can be explained by erosion of the plasma. Magnetic pressure is insufficient to open the gap

  9. Current distribution in a plasma erosion opening switch

    International Nuclear Information System (INIS)

    Weber, B.V.; Commisso, R.J.; Meger, R.A.; Neri, J.M.; Oliphant, W.F.; Ottinger, P.F.

    1985-01-01

    The current distribution in a plasma erosion opening switch is determined from magnetic field probe data. During the closed state of the switch the current channel broadens rapidly. The width of the current channel is consistent with a bipolar current density limit imposed by the ion flux to the cathode. The effective resistivity of the current channel is anomalously large. Current is diverted to the load when a gap opens near the cathode side of the switch. The observed gap opening can be explained by erosion of the plasma. Magnetic pressure is insufficient to open the gap

  10. Magnetic field modification of optical magnetic dipoles.

    Science.gov (United States)

    Armelles, Gaspar; Caballero, Blanca; Cebollada, Alfonso; Garcia-Martin, Antonio; Meneses-Rodríguez, David

    2015-03-11

    Acting on optical magnetic dipoles opens novel routes to govern light-matter interaction. We demonstrate magnetic field modification of the magnetic dipolar moment characteristic of resonant nanoholes in thin magnetoplasmonic films. This is experimentally shown through the demonstration of the magneto-optical analogue of Babinet's principle, where mirror imaged MO spectral dependencies are obtained for two complementary magnetoplasmonic systems: holes in a perforated metallic layer and a layer of disks on a substrate.

  11. Signature of open magnetic field lines in the extended solar corona and of solar wind acceleration

    Science.gov (United States)

    Antonucci, E.; Giordano, S.; Benna, C.; Kohl, J. L.; Noci, G.; Michels, J.; Fineschi, S.

    1997-01-01

    The observations carried out with the ultraviolet coronagraph spectrometer onboard the Solar and Heliospheric Observatory (SOHO) are discussed. The purpose of the observations was to determine the line of sight and radial velocity fields in coronal regions with different magnetic topology. The results showed that the regions where the high speed solar wind flows along open field lines are characterized by O VI 1032 and HI Lyman alpha 1216 lines. The global coronal maps of the line of sight velocity were reconstructed. The corona height, where the solar wind reaches 100 km/s, was determined.

  12. Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner

    International Nuclear Information System (INIS)

    Wonneberger, Uta; Schnackenburg, Bernhard; Streitparth, Florian; Walter, Thula; Rump, Jens; Teichgraeber, Ulf K. M.

    2010-01-01

    In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0 o to 90 o ) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width o to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR Muscle/Needle >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

  13. Potential formation in a collisionless plasma produced in an open magnetic field in presence of volume negative ion source

    International Nuclear Information System (INIS)

    Phukan, Ananya; Goswami, K. S.; Bhuyan, P. J.

    2014-01-01

    The electric potential near a wall for a multi-species plasma with volume produced negative ions in presence of axially varying magnetic field is studied following an analytical-numerical approach. A constant negative ion source is assumed throughout the plasma volume, along with finite temperature positive ions and Boltzmann electrons. The particles are assumed to be guided by an open magnetic field that has its maximum at the centre, and field strength decreasing towards the walls. The one dimensional (1D) Poisson equation is derived using an analytical approach, and then solved numerically to study the potential profiles. Effect of (a) negative ion production rate, (b) magnetic field profile, and (c) negative ion temperature on the potential profile has been investigated. A potential peak appears near the wall when the negative ion temperature and density are sufficiently high. Also, the presence of negative ions further decreases the potential in the plasma region for a finite Debye Length (λ D )

  14. Magnetic shielding for MRI superconducting magnets

    International Nuclear Information System (INIS)

    Ishiyama, A.; Hirooka, H.

    1991-01-01

    This paper describes an optimal design of a highly homogeneous superconducting coil system with magnetic shielding for Magnetic Resonance Imaging (MRI). The presented optimal design method; which is originally proposed in our earlier papers, is a combination of the hybrid finite element and boundary element method for analysis of an axially symmetric nonlinear open boundary magnetic field problem, and the mathematical programming method for solving the corresponding optimization problem. In this paper, the multi-objective goal programming method and the nonlinear least squares method have been adopted. The optimal design results of 1.5- and 4.7-Tesla-magnet systems with different types of magnetic shielding for whole-body imaging are compared and the advantages of a combination of active and yoke shields are shown

  15. Vibration and Noise in Magnetic Resonance Imaging of the Vocal Tract: Differences between Whole-Body and Open-Air Devices.

    Science.gov (United States)

    Přibil, Jiří; Přibilová, Anna; Frollo, Ivan

    2018-04-05

    This article compares open-air and whole-body magnetic resonance imaging (MRI) equipment working with a weak magnetic field as regards the methods of its generation, spectral properties of mechanical vibration and acoustic noise produced by gradient coils during the scanning process, and the measured noise intensity. These devices are used for non-invasive MRI reconstruction of the human vocal tract during phonation with simultaneous speech recording. In this case, the vibration and noise have negative influence on quality of speech signal. Two basic measurement experiments were performed within the paper: mapping sound pressure levels in the MRI device vicinity and picking up vibration and noise signals in the MRI scanning area. Spectral characteristics of these signals are then analyzed statistically and compared visually and numerically.

  16. GRHydro: a new open-source general-relativistic magnetohydrodynamics code for the Einstein toolkit

    International Nuclear Information System (INIS)

    Mösta, Philipp; Haas, Roland; Ott, Christian D; Reisswig, Christian; Mundim, Bruno C; Faber, Joshua A; Noble, Scott C; Bode, Tanja; Löffler, Frank; Schnetter, Erik

    2014-01-01

    We present the new general-relativistic magnetohydrodynamics (GRMHD) capabilities of the Einstein toolkit, an open-source community-driven numerical relativity and computational relativistic astrophysics code. The GRMHD extension of the toolkit builds upon previous releases and implements the evolution of relativistic magnetized fluids in the ideal MHD limit in fully dynamical spacetimes using the same shock-capturing techniques previously applied to hydrodynamical evolution. In order to maintain the divergence-free character of the magnetic field, the code implements both constrained transport and hyperbolic divergence cleaning schemes. We present test results for a number of MHD tests in Minkowski and curved spacetimes. Minkowski tests include aligned and oblique planar shocks, cylindrical explosions, magnetic rotors, Alfvén waves and advected loops, as well as a set of tests designed to study the response of the divergence cleaning scheme to numerically generated monopoles. We study the code’s performance in curved spacetimes with spherical accretion onto a black hole on a fixed background spacetime and in fully dynamical spacetimes by evolutions of a magnetized polytropic neutron star and of the collapse of a magnetized stellar core. Our results agree well with exact solutions where these are available and we demonstrate convergence. All code and input files used to generate the results are available on http://einsteintoolkit.org. This makes our work fully reproducible and provides new users with an introduction to applications of the code. (paper)

  17. Image correction during large and rapid B(0) variations in an open MRI system with permanent magnets using navigator echoes and phase compensation.

    Science.gov (United States)

    Li, Jianqi; Wang, Yi; Jiang, Yu; Xie, Haibin; Li, Gengying

    2009-09-01

    An open permanent magnet system with vertical B(0) field and without self-shielding can be quite susceptible to perturbations from external magnetic sources. B(0) variation in such a system located close to a subway station was measured to be greater than 0.7 microT by both MRI and a fluxgate magnetometer. This B(0) variation caused image artifacts. A navigator echo approach that monitored and compensated the view-to-view variation in magnetic resonance signal phase was developed to correct for image artifacts. Human brain imaging experiments using a multislice gradient-echo sequence demonstrated that the ghosting and blurring artifacts associated with B(0) variations were effectively removed using the navigator method.

  18. Sidewall containment of liquid metal with horizontal alternating magnetic fields

    International Nuclear Information System (INIS)

    Pareg, W.F.

    1990-01-01

    This patent describes an apparatus for confining molten metal. It comprises: containment means having an open side; a magnet capable of generating a mainly horizontal alternating magnetic field. The the magnet is located adjacent to the open side of the containment means whereby the field generated by the magnet is capable of inducing eddy currents in a thin layer at the surface of the molten metal which interact with the magnetic field producing a force that can contain the molten metal within the containment means; wherein the magnet includes: magnetic poles located adjacent to the open side of the confinement means; a core connecting the poles; a coil encircling the core, the coil capable of being responsive to a current source; whereby an alternating magnetic field can be generated between the poles and parallel to the open side of the containment means so that a molten metal can be confined within the confinement means

  19. Collection of Ni-bearing material from electroless plating waste by magnetic separation with HTS bulk magnet

    Science.gov (United States)

    Oka, T.; Fukazawa, H.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Tsujimura, M.; Yokoyama, K.

    2014-01-01

    The magnetic separation experiment to collect the Ni compounds from the waste liquid of electroless plating processes was conducted in the open-gradient magnetic separation process with the high temperature superconducting bulk magnet system. The magnetic pole containing Gd-based bulk superconductors was activated to 3.45 T at 35 K in the static magnetic field of 5 T with use of a superconducting solenoid magnet. The coarse Ni-sulfate crystals were formed by adding the concentrated sulfuric acid to the Ni-phosphite precipitates which yielded from the plating waste liquid by controlling the temperature and the pH value. The open-gradient magnetic separation technique was employed to separate the Ni-sulfate crystals from the mixture of the Ni-sulfate and Ni-phosphite compounds by the difference between their magnetic properties. And we succeeded in collecting Ni-sulfate crystals preferentially to the Ni-phosphite by attracting them to the magnetic pole soon after the Ni-sulfate crystals began to grow.

  20. On the theory of Heiser and Shercliff experiment. Part 1: MHD flow in an open channel in strong uniform magnetic field

    Science.gov (United States)

    Molokov, S. Y.; Allen, J. E.

    Magnetohydrodynamic (MHD) flows of viscous incompressible fluid in strong magnetic fields parallel to a free surface of fluid are investigated. The problem of flow in an open channel due to a moving side wall in uniform magnetic field is considered, and treated by means of matched asymptotic expansions method. The flow region is divided into various subregions and leading terms of asymptotic expansions as M tends towards infinity (M is the Hartmann number) of solutions of correspondent problems in each subregion are obtained. An exact analytic solution of equations governing the free-surface layer of thickness of order M to the minus 1/2 power is obtained.

  1. Full-thickness knee articular cartilage defects in national football league combine athletes undergoing magnetic resonance imaging: prevalence, location, and association with previous surgery.

    Science.gov (United States)

    Nepple, Jeffrey J; Wright, Rick W; Matava, Matthew J; Brophy, Robert H

    2012-06-01

    To better define the prevalence and location of full-thickness articular cartilage lesions in elite football players undergoing knee magnetic resonance imaging (MRI) at the National Football League (NFL) Invitational Combine and assess the association of these lesions with previous knee surgery. We performed a retrospective review of all participants in the NFL Combine undergoing a knee MRI scan from 2005 to 2009. Each MRI scan was reviewed for evidence of articular cartilage disease. History of previous knee surgery including anterior cruciate ligament reconstruction, meniscal procedures, and articular cartilage surgery was recorded for each athlete. Knees with a history of previous articular cartilage restoration surgery were excluded from the analysis. A total of 704 knee MRI scans were included in the analysis. Full-thickness articular cartilage lesions were associated with a history of any previous knee surgery (P football players at the NFL Combine undergoing MRI. The lateral compartment appears to be at greater risk for full-thickness cartilage loss. Previous knee surgery, particularly meniscectomy, is associated with these lesions. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  2. Vibration and Noise in Magnetic Resonance Imaging of the Vocal Tract: Differences between Whole-Body and Open-Air Devices

    Directory of Open Access Journals (Sweden)

    Jiří Přibil

    2018-04-01

    Full Text Available This article compares open-air and whole-body magnetic resonance imaging (MRI equipment working with a weak magnetic field as regards the methods of its generation, spectral properties of mechanical vibration and acoustic noise produced by gradient coils during the scanning process, and the measured noise intensity. These devices are used for non-invasive MRI reconstruction of the human vocal tract during phonation with simultaneous speech recording. In this case, the vibration and noise have negative influence on quality of speech signal. Two basic measurement experiments were performed within the paper: mapping sound pressure levels in the MRI device vicinity and picking up vibration and noise signals in the MRI scanning area. Spectral characteristics of these signals are then analyzed statistically and compared visually and numerically.

  3. MR cholangio-pancreatography using an open, low magnetic field of 0.2 Tesla. Early clinical results and comparison with a higher magnetic field (1.5 Tesla) and with ERCP

    International Nuclear Information System (INIS)

    Wacker, Q.; Branding, G.; Wolf, K.J.; Zimmer, T.; Faiss, S.

    1997-01-01

    Aim: To evaluate MR cholangio-pancreatography (MRCP) using an open low magnetic field apparatus in normals and in patients with mechanical cholestasis. Methods: MRCP was performed on five normals and on 30 patients, using both an 0.2 Tesla and 1.5 Tesla apparatus. With the low field system, rapid acquisition by relaxation enhancement was used, for the high field system, half Fourier acquisition single shot turbo spin-echo sequences were used. In all patients, sonography and ERCP of PTC was performed; 23 underwent surgery. Results: In all normals it was possible to show the bile duct, hepatic duct, gall bladder and intrahepatic ducts of the first order. Using the high field system, second order ducts could be shown and sometimes third order ducts. In the patients, MRCP, using either system, demonstrated all 21 obstructive sites due to tumours or stenoses. Stones were shown in 69% by the low field system and in 88% by the high field system. Conclusion: MRCP can be successfully carried out using the low field system. In the presence of mechanical cholestasis, image quality is adequate for the localisation of stenoses and occlusions, and using an open magnet, is suitable for planning further intervention. (orig.) [de

  4. Intermittent theta-burst transcranial magnetic stimulation for autism spectrum disorder: an open-label pilot study

    Directory of Open Access Journals (Sweden)

    Caio Abujadi

    2017-12-01

    Full Text Available Objective: Theta-burst stimulation (TBS modulates synaptic plasticity more efficiently than standard repetitive transcranial magnetic stimulation delivery and may be a promising modality for neuropsychiatric disorders such as autism spectrum disorder (ASD. At present there are few effective interventions for prefrontal cortex dysfunction in ASD. We report on an open-label, pilot study of intermittent TBS (iTBS to target executive function deficits and restricted, repetitive behaviors in male children and adolescents with ASD. Methods: Ten right-handed, male participants, aged 9-17 years with ASD were enrolled in an open-label trial of iTBS treatment. Fifteen sessions of neuronavigated iTBS at 100% motor threshold targeting the right dorsolateral prefrontal cortex were delivered over 3 weeks. Results: Parent report scores on the Repetitive Behavior Scale Revised and the Yale-Brown Obsessive Compulsive Scale demonstrated improvements with iTBS treatment. Participants demonstrated improvements in perseverative errors on the Wisconsin Card Sorting Test and total time for the Stroop test. The iTBS treatments were well tolerated with no serious adverse effects. Conclusion: These preliminary results suggest that further controlled interventional studies of iTBS for ASD are warranted.

  5. Intermittent theta-burst transcranial magnetic stimulation for autism spectrum disorder: an open-label pilot study.

    Science.gov (United States)

    Abujadi, Caio; Croarkin, Paul E; Bellini, Bianca B; Brentani, Helena; Marcolin, Marco A

    2017-12-11

    Theta-burst stimulation (TBS) modulates synaptic plasticity more efficiently than standard repetitive transcranial magnetic stimulation delivery and may be a promising modality for neuropsychiatric disorders such as autism spectrum disorder (ASD). At present there are few effective interventions for prefrontal cortex dysfunction in ASD. We report on an open-label, pilot study of intermittent TBS (iTBS) to target executive function deficits and restricted, repetitive behaviors in male children and adolescents with ASD. Ten right-handed, male participants, aged 9-17 years with ASD were enrolled in an open-label trial of iTBS treatment. Fifteen sessions of neuronavigated iTBS at 100% motor threshold targeting the right dorsolateral prefrontal cortex were delivered over 3 weeks. Parent report scores on the Repetitive Behavior Scale Revised and the Yale-Brown Obsessive Compulsive Scale demonstrated improvements with iTBS treatment. Participants demonstrated improvements in perseverative errors on the Wisconsin Card Sorting Test and total time for the Stroop test. The iTBS treatments were well tolerated with no serious adverse effects. These preliminary results suggest that further controlled interventional studies of iTBS for ASD are warranted.

  6. The efficacy of magnetic field on the thermal behavior of MnFe{sub 2}O{sub 4} nanofluid as a functional fluid through an open-cell metal foam tube

    Energy Technology Data Exchange (ETDEWEB)

    Amani, Mohammad [Mechanical and Energy Engineering Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Ameri, Mohammad, E-mail: ameri_m@yahoo.com [Mechanical and Energy Engineering Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Kasaeian, Alibakhsh [Department of Renewable Energies Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran (Iran, Islamic Republic of)

    2017-06-15

    Highlights: • Experiments are performed with MnFe{sub 2}O{sub 4} nanofluid through an open-cell metal foam tube. • Effects of concentration, Reynolds number and magnetic field on the nanofluid thermal behavior are examined. • Heat transfer is enhanced in attendance of constant and alternating magnetic fields. - Abstract: In the present experimental study, the influence of permanent and alternating magnetic fields on the flow and thermal behavior of MnFe{sub 2}O{sub 4} magnetic nanofluid flowing through a circular open-cell metal foam tube is investigated under homogeneous heat flux conditions. The experiments are performed at various nanoparticle concentrations, Reynolds numbers and magnetic fields with different strengths and frequencies. According to the observations, the heat transfer rate enhances directly relative to nanoparticle concentration and Reynolds number in attendance of magnetic field, whereas its maximum value of 16.4% is found for 2 wt% nanoparticles at Re = 200 under alternating field with 400 G strength and 20 Hz frequency. Moreover, it is observed that the influence of strength and frequency of magnetic field is insignificant for the pressure drop. Hydrothermal efficiency as the ratio of the Nusselt number to the ratio of the pressure drop is defined in order to evaluate the privilege of using MnFe{sub 2}O{sub 4} nanofluids in practical applications. The maximum efficiency of 1.25 is observed at 2 wt% under magnetic field with 400 G and 20 Hz at Re = 1000.

  7. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  8. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  9. Rotation and toroidal magnetic field effects on the stability of two-component jets

    Science.gov (United States)

    Millas, Dimitrios; Keppens, Rony; Meliani, Zakaria

    2017-09-01

    Several observations of astrophysical jets show evidence of a structure in the direction perpendicular to the jet axis, leading to the development of 'spine and sheath' models of jets. Most studies focus on a two-component jet consisting of a highly relativistic inner jet and a slower - but still relativistic - outer jet surrounded by an unmagnetized environment. These jets are believed to be susceptible to a relativistic Rayleigh-Taylor-type instability, depending on the effective inertia ratio of the two components. We extend previous studies by taking into account the presence of a non-zero toroidal magnetic field. Different values of magnetization are examined to detect possible differences in the evolution and stability of the jet. We find that the toroidal field, above a certain level of magnetization σ, roughly equal to 0.01, can stabilize the jet against the previously mentioned instabilities and that there is a clear trend in the behaviour of the average Lorentz factor and the effective radius of the jet when we continuously increase the magnetization. The simulations are performed using the relativistic MHD module from the open source, parallel, grid adaptive, mpi-amrvac code.

  10. MAGNETIC DIAGNOSTICS OF THE SOLAR CHROMOSPHERE WITH THE Mg II h–k LINES

    Energy Technology Data Exchange (ETDEWEB)

    Del Pino Alemán, T.; Casini, R. [High Altitude Observatory, National Center for Atmospheric Research, P.O. Box 3000, Boulder, CO 80307-3000 (United States); Manso Sainz, R. [Max-Planck-Institut für Sonnensystemforschung, Justus-von-Liebig-Weg 3, D-37077 Göttingen (Germany)

    2016-10-20

    We investigated the formation of the Mg ii h–k doublet in a weakly magnetized atmosphere (20–100 G) using a newly developed numerical code for polarized radiative transfer in a plane-parallel geometry, which implements a recent formulation of partially coherent scattering by polarized multi-term atoms in arbitrary magnetic-field regimes. Our results confirm the importance of partial redistribution effects in the formation of the Mg ii h and k lines, as pointed out by previous work in the non-magnetic case. We show that the presence of a magnetic field can produce measurable modifications of the broadband linear polarization even for relatively small field strengths (∼10 G), while the circular polarization remains well represented by the classical magnetograph formula. Both these results open an important new window for the weak-field diagnostics of the upper solar atmosphere.

  11. Study of edge turbulence from the open to closed magnetic field configuration during the current ramp-up phase in QUEST

    International Nuclear Information System (INIS)

    Zushi, H.; Hanada, K.; Nishino, N.

    2010-11-01

    Statistical features of fluctuations including blobs are investigated using the CCD imaging technique in open and closed magnetic configurations. In a simple open magnetic configuration with vertical (B z ) and toroidal fields (B t ) slab plasma produced by electron cyclotron waves is studied as a function of B z /B t . It is found that fluctuations become dominated by blobs depending on the ratio B z /B t . In the plasma source region R s helix-sinusoidal perturbations are exited, whose helix angle and vertical wavelength are consistent with pitch angle and turn distance of the magnetic field lines there. Steep gradient in the intermediate region R im outside R s triggers the plasma to expand radially as a blob ejection. Along the ridge line of the maximum inverse scale length a wave front of the helix perturbation moves outward. Acceleration of a blob is found in the source-free region R sf . It is found that the probability density function pdf of fluctuations in all B z /B t experiments is close to a gamma distribution. Ohmic plasma is ramped-up from the slab plasma and closed surface LCFS is formed. Fluctuations inboard side and outer scrape off layer SOL are studied in this process. Former one is characterized by small amplitude fluctuation level δI/I-a few %, but latter one shows intermittent large amplitude. Two dimensional structures of the higher moments (skewness S and kurtosis k) representing the shape of pdf are studied. In the former it is observed that these structures consistent with the LCFS, and the pdf is close to a Gaussian distribution. The numerical coefficients characterizing the Pearson system are also derived. In the outboard SOL, it is found that S and k are not only a function of the magnetic flux, but also the magnetic field lines. The pdf is consistent with the Gaussian one for 0.1m from the LCFS, and becomes beta and gamma ones far from the LCFS. Based on the observed numerical coefficients in the Pearson system a relation between

  12. SQUID magnetometer using sensitivity correction signal for non-magnetic metal contaminants detection

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Toshifumi, E-mail: sakuta.k@usp.ac.jp; Ohashi, Masaharu; Sakuta, Ken

    2016-11-15

    Highlights: • A high-frequency excitation is necessary to detect nonmagnetic metals using SQUID. • It is possible to detect a high-frequency magnetic field using the open loop technique. • Open loop operation leads to a change in the conversion factor. • Conversion between voltage and magnetic field for open loop operation are examined. - Abstract: Measurement methods with SQUID can accurately detect small magnetic metal contaminants based on their magnetic remanence. But, a high-frequency excitation is necessary to detect nonmagnetic metals, on the base of contrasts in electric conductivity. In this work, an open loop technique is introduced to facilitate this. The SQUID is negative feedback controlled (flux locked loop (FLL) operation) for the low frequency range, which includes significant noise due to the movement of the magnetic body or the change of the ambient magnetic field composed of the geomagnetic field and technical signals, and it operates in an open loop configuration for the high frequency range. When using the open loop technique, negative feedback is not applied to the high frequency range. Consequently, the V–Φ characteristic changes due to various causes, which leads to variations in the conversion factor between the SQUID output voltage and the magnetic field. In this study, conversion techniques for the magnetic field for open loop operation of SQUID in the high frequency range are examined.

  13. SQUID magnetometer using sensitivity correction signal for non-magnetic metal contaminants detection

    International Nuclear Information System (INIS)

    Yagi, Toshifumi; Ohashi, Masaharu; Sakuta, Ken

    2016-01-01

    Highlights: • A high-frequency excitation is necessary to detect nonmagnetic metals using SQUID. • It is possible to detect a high-frequency magnetic field using the open loop technique. • Open loop operation leads to a change in the conversion factor. • Conversion between voltage and magnetic field for open loop operation are examined. - Abstract: Measurement methods with SQUID can accurately detect small magnetic metal contaminants based on their magnetic remanence. But, a high-frequency excitation is necessary to detect nonmagnetic metals, on the base of contrasts in electric conductivity. In this work, an open loop technique is introduced to facilitate this. The SQUID is negative feedback controlled (flux locked loop (FLL) operation) for the low frequency range, which includes significant noise due to the movement of the magnetic body or the change of the ambient magnetic field composed of the geomagnetic field and technical signals, and it operates in an open loop configuration for the high frequency range. When using the open loop technique, negative feedback is not applied to the high frequency range. Consequently, the V–Φ characteristic changes due to various causes, which leads to variations in the conversion factor between the SQUID output voltage and the magnetic field. In this study, conversion techniques for the magnetic field for open loop operation of SQUID in the high frequency range are examined.

  14. On noncommutative open string theories

    International Nuclear Information System (INIS)

    Russo, J.G.; Sheikh-Jabbari, M.M.

    2000-08-01

    We investigate new compactifications of OM theory giving rise to a 3+1 dimensional open string theory with noncommutative x 0 -x 1 and x 2 -x 3 coordinates. The theory can be directly obtained by starting with a D3 brane with parallel (near critical) electric and magnetic field components, in the presence of a RR scalar field. The magnetic parameter permits to interpolate continuously between the x 0 -x 1 noncommutative open string theory and the x 2 -x 3 spatial noncommutative U(N) super Yang-Mills theory. We discuss SL(2, Z) transformations of this theory. Using the supergravity description of the large N limit, we also compute corrections to the quark-antiquark Coulomb potential arising in the NCOS theory. (author)

  15. Long conduction time plasma opening switch experiments at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Savage, M.E.; Simpson, W.W.; Cooper, G.W.; Usher, M.A.

    1993-01-01

    Sandia National Laboratories has undertaken an ambitious program to reduce the size and cost of large pulsed power drivers. The program basis is inductive energy storage and Plasma Opening Switches (POS). Inductive energy storage has well known advantages, including increased efficiency and reduced stress on the vacuum interface. The Sandia approach is to retain the reliable and efficient Marx generator and the temporal pulse compression of the water dielectric capacitor. A triggered closing switch, developed at Sandia, transfers the capacitor charge into the energy storage inductor. This approach has several advantages, including relaxed requirements on Marx jitter and inductance, and much faster current risetime in the energy storage inductor. The POS itself is the key to the Sandia program. The switch design uses an auxiliary magnetic field to inject the plasma and hold it in place during conduction. After opening begins, the self magnetic field of the power pulse pushes on the plasma to increase the opened gap. The authors use magnetic pressure because they desire POS gaps of several cm. Typical plasma opening switches do not achieve large gaps. Improved opening allows more efficient transfer to loads. They present results from recent experiments at Sandia. Their driver presently supplies 650 kA with a 240 ns risetime to the input of the POS. The storage inductor is a 17 Ohm magnetically insulated transmission line (MITL) that is five meters long. They discuss the ways in which magnetic field influences the POS, and the ways in which they control the magnetic fields

  16. OpenBEM - An open source Boundary Element Method software in Acoustics

    DEFF Research Database (Denmark)

    Cutanda Henriquez, Vicente; Juhl, Peter Møller

    2010-01-01

    OpenBEM is a collection of open source programs for solving the Helmholtz Equation using the Boundary Element Method. The collection is written in Matlab by the authors and contains codes for dealing with exterior and interior problems in two or three dimensions as well as implementation of axi...... with examples of its use. Previous research results where OpenBEM was employed will be mentioned....

  17. Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design

    International Nuclear Information System (INIS)

    Paulsen, Jeffrey L; Franck, John; Demas, Vasiliki; Bouchard, Louis-S.

    2008-01-01

    Single-sided and mobile nuclear magnetic resonance (NMR) sensors have the advantages of portability, low cost, and low power consumption compared to conventional high-field NMR and magnetic resonance imaging (MRI) systems. We present fast, flexible, and easy-to-implement target field algorithms for mobile NMR and MRI magnet design. The optimization finds a global optimum in a cost function that minimizes the error in the target magnetic field in the sense of least squares. When the technique is tested on a ring array of permanent-magnet elements, the solution matches the classical dipole Halbach solution. For a single-sided handheld NMR sensor, the algorithm yields a 640 G field homogeneous to 16,100 ppm across a 1.9 cc volume located 1.5 cm above the top of the magnets and homogeneous to 32,200 ppm over a 7.6 cc volume. This regime is adequate for MRI applications. We demonstrate that the homogeneous region can be continuously moved away from the sensor by rotating magnet rod elements, opening the way for NMR sensors with adjustable 'sensitive volumes'

  18. Intraoperative Magnetic Resonance Imaging for Cranial and Spinal Cases Using Preexisting "C" Shaped Three Side Open 0.2 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Tewari, Vinod Kumar; Tripathi, Ravindra; Aggarwal, Subodh; Hussain, Mazhar; Das Gupta, Hari Kishan

    2017-01-01

    The existing Intraoperative MRI (IMRI) of developed countries is too costly to be affordable in any developing country and out of the reach of common and poor people of developing country at remote areas. We have used the pre-existing (refurbished) 3 side open "C" shaped 0.2 Tesla MRI for IMRI in a very remote area. In this technique the 0.2 Tesla MRI and the operating theatre were merged. MRI table was used as an operation table. We have operated 36 cases via IMRI from November 2005 to till date. First case operated was on 13 th nov 2005. Low (0.2) Tesla open setup costs very low (around Rs 40 lakhs) so highly affordable to management and thus to patients, used for diagnostic and therapeutic purposes both, the equipments like Nitrous, oxygen and suction is outside the MRI room so no noise inside operative room, positioning the patient didn't take much time due to manual adjustments, no special training to nurses and technicians required because of low (0.2) Tesla power of magnet and same instruments and techniques, sequencing took only 1.31 mints per sequence and re registration is not required since we always note down the two orthogonal axis in x and y axis in preoperative imaging and we were able to operate on posterior fossa tumors as well because of no head fixation except with leucoplast strap. Moreover the images we got intraoperative are highly acceptable. Three side open 0.2 Tesla MRI system, if used for intraoperative guidance, is highly affordable and overcomes the limitations of western setup of IMRI. Postoperative MRI images were highly acceptable and also highly affordable too.

  19. Open and disconnected magnetic field lines within coronal mass ejections in the solar wind: Evidence for 3-dimensional reconnection

    Science.gov (United States)

    Gosling, J. T.; Birn, J.; McComas, D. J.; Phillips, J. L.; Hesse, M.

    1995-01-01

    Measurements of suprathermal electron fluxes in the solar wind at energies greater than approximatley 80 eV indicate that magnetic field lines within coronal mass ejections. CMEs, near and beyond 1 AU are normally connected to the Sun at both ends. However, a preliminary reexamination of events previously identified as CMEs in the ISEE 3 data reveals that about 1/4 of all such events contain limited regions where field lines appear to be either connected to the Sun at only one end or connected to the outer heliosphere at both ends. Similar intervals of open and disconnected field lines within CMEs have been identified in the Ulysses observations. We believe that these anomalous field topologies within CMEs are most naturally interpreted in terms of 3-dimensional reconnection behind CMEs close to the Sun. Such reconnection also provides a natural explanation both for the flux rope topology of many CMEs as well as the coronal loops formed during long-duration solar soft X ray events. Although detailed numerical simulations of 3-dimensional reconnection behind CMEs are not yet available, such simulations have been done for the qualitatively similar geometry that prevails within the geomagnetic tail. Those simulations of plasmoid formation in the geomagnetic tail do produce the mixture of field topologies within plasmoids discussed here for CMEs.

  20. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...

  1. Successful Magnetic Resonance Imaging-Guided Focused Ultrasound Surgery for Recurrent Uterine Fibroid Previously Treated with Uterine Artery Embolization

    Directory of Open Access Journals (Sweden)

    Sang-Wook Yoon

    2010-01-01

    Full Text Available A 45-year-old premenopausal woman was referred to our clinic due to recurring symptoms of uterine fibroids, nine years after a uterine artery embolization (UAE. At the time of screening, the patient presented with bilateral impairment and narrowing of the uterine arteries, which increased the risk of arterial perforation during repeated UAE procedures. The patient was subsequently referred for magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS treatment. Following the treatment, the patient experienced a significant improvement in symptoms (symptom severity score was reduced from 47 to 12 by 1 year post-treatment. MR images at 3 months showed a 49% decrease in fibroid volume. There were no adverse events during the treatment or the follow-up period. This case suggests that MRgFUS can be an effective treatment option for patients with recurrent fibroids following previous UAE treatment.

  2. ULYSSES OBSERVATIONS OF THE MAGNETIC CONNECTIVITY BETWEEN CORONAL, MASS EJECTIONS AND THE SUN

    Science.gov (United States)

    Riley, Pete; Goslin, J. T.; Crooker, . U.

    2004-01-01

    We have investigated the magnetic connectivity of coronal mass ejections (CMEs) to the Sun using Ulysses observations of suprathermal electrons at various distances between 1 and 5.2 AU. Drawing on ideas concerning the eruption and evolution of CMEs, we had anticipated that there might be a tendency for CMEs to contain progressively more open field lines, as reconnection back at the Sun either opened or completely disconnected previously closed field lines threading the CMEs. Our results, however, did not yield any discernible trend. By combining the potential contribution of CMEs to the heliospheric flux with the observed buildup of flux during the course of the solar cycle, we also derive a lower limit for the reconnection rate of CMEs that is sufficient to avoid the "flux catastrophe" paradox. This rate is well below our threshold of detectability. Subject headings: solar wind - Sun: activity - Sun: corona - Sun: coronal mass ejections (CMEs) - On-line material: color figure Sun: magnetic fields

  3. Collection of Ni-bearing material from electroless plating waste by magnetic separation with HTS bulk magnet

    International Nuclear Information System (INIS)

    Oka, T.; Fukazawa, H.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Tsujimura, M.; Yokoyama, K.

    2014-01-01

    Highlights: ► The magnetic separation for Ni compounds was conducted by HTS bulk magnet. ► The coarse Ni-sulfate crystals were formed from the Ni-phosphite precipitates. ► Ni-sulfate crystals was separated from the mixture of Ni-sulfate and Ni-phosphite compounds. -- Abstract: The magnetic separation experiment to collect the Ni compounds from the waste liquid of electroless plating processes was conducted in the open-gradient magnetic separation process with the high temperature superconducting bulk magnet system. The magnetic pole containing Gd-based bulk superconductors was activated to 3.45 T at 35 K in the static magnetic field of 5 T with use of a superconducting solenoid magnet. The coarse Ni-sulfate crystals were formed by adding the concentrated sulfuric acid to the Ni-phosphite precipitates which yielded from the plating waste liquid by controlling the temperature and the pH value. The open-gradient magnetic separation technique was employed to separate the Ni-sulfate crystals from the mixture of the Ni-sulfate and Ni-phosphite compounds by the difference between their magnetic properties. And we succeeded in collecting Ni-sulfate crystals preferentially to the Ni-phosphite by attracting them to the magnetic pole soon after the Ni-sulfate crystals began to grow

  4. Collection of Ni-bearing material from electroless plating waste by magnetic separation with HTS bulk magnet

    Energy Technology Data Exchange (ETDEWEB)

    Oka, T., E-mail: okat@eng.niigata-u.ac.jp [Niigata University, 8050 Ikarashi-Ninocho, Nishi-ku, Niigata 950-2181 (Japan); Fukazawa, H.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M. [Niigata University, 8050 Ikarashi-Ninocho, Nishi-ku, Niigata 950-2181 (Japan); Tsujimura, M. [Aichi Giken Co., 50-1 Takeshita, Hitotugi-cho, Kariya, Aichi 448-0003 (Japan); Yokoyama, K. [Ashikaga Institute of Technology, 268-1 Ohmae-cho, Ashikaga, Tochigi 326-8558 (Japan)

    2014-01-15

    Highlights: ► The magnetic separation for Ni compounds was conducted by HTS bulk magnet. ► The coarse Ni-sulfate crystals were formed from the Ni-phosphite precipitates. ► Ni-sulfate crystals was separated from the mixture of Ni-sulfate and Ni-phosphite compounds. -- Abstract: The magnetic separation experiment to collect the Ni compounds from the waste liquid of electroless plating processes was conducted in the open-gradient magnetic separation process with the high temperature superconducting bulk magnet system. The magnetic pole containing Gd-based bulk superconductors was activated to 3.45 T at 35 K in the static magnetic field of 5 T with use of a superconducting solenoid magnet. The coarse Ni-sulfate crystals were formed by adding the concentrated sulfuric acid to the Ni-phosphite precipitates which yielded from the plating waste liquid by controlling the temperature and the pH value. The open-gradient magnetic separation technique was employed to separate the Ni-sulfate crystals from the mixture of the Ni-sulfate and Ni-phosphite compounds by the difference between their magnetic properties. And we succeeded in collecting Ni-sulfate crystals preferentially to the Ni-phosphite by attracting them to the magnetic pole soon after the Ni-sulfate crystals began to grow.

  5. Passive magnetic shielding in MRI-Linac systems

    Science.gov (United States)

    Whelan, Brendan; Kolling, Stefan; Oborn, Brad M.; Keall, Paul

    2018-04-01

    Passive magnetic shielding refers to the use of ferromagnetic materials to redirect magnetic field lines away from vulnerable regions. An application of particular interest to the medical physics community is shielding in MRI systems, especially integrated MRI-linear accelerator (MRI-Linac) systems. In these systems, the goal is not only to minimize the magnetic field in some volume, but also to minimize the impact of the shield on the magnetic fields within the imaging volume of the MRI scanner. In this work, finite element modelling was used to assess the shielding of a side coupled 6 MV linac and resultant heterogeneity induced within the 30 cm diameter of spherical volume (DSV) of a novel 1 Tesla split bore MRI magnet. A number of different shield parameters were investigated; distance between shield and magnet, shield shape, shield thickness, shield length, openings in the shield, number of concentric layers, spacing between each layer, and shield material. Both the in-line and perpendicular MRI-Linac configurations were studied. By modifying the shield shape around the linac from the starting design of an open ended cylinder, the shielding effect was boosted by approximately 70% whilst the impact on the magnet was simultaneously reduced by approximately 10%. Openings in the shield for the RF port and beam exit were substantial sources of field leakage; however it was demonstrated that shielding could be added around these openings to compensate for this leakage. Layering multiple concentric shield shells was highly effective in the perpendicular configuration, but less so for the in-line configuration. Cautious use of high permeability materials such as Mu-metal can greatly increase the shielding performance in some scenarios. In the perpendicular configuration, magnetic shielding was more effective and the impact on the magnet lower compared with the in-line configuration.

  6. Transformation magneto-statics and illusions for magnets

    Science.gov (United States)

    Sun, Fei; He, Sailing

    2014-10-01

    Based on the form-invariant of Maxwell's equations under coordinate transformations, we extend the theory of transformation optics to transformation magneto-statics, which can design magnets through coordinate transformations. Some novel DC magnetic field illusions created by magnets (e.g. rescaling magnets, cancelling magnets and overlapping magnets) are designed and verified by numerical simulations. Our research will open a new door to designing magnets and controlling DC magnetic fields.

  7. A novel permanently magnetised high gradient magnetic filter using assisted capture for fine particles

    Energy Technology Data Exchange (ETDEWEB)

    Watson, J.H.P. [Univ. of Southampton (United Kingdom)

    1995-02-01

    This paper describes the structure and properties of a novel permanently magnetised magnetic filter for fine friable radioactive material. Previously a filter was described and tested. This filter was designed so that the holes in the filter are left open as capture proceeds which means the pressure drop builds up only slowly. This filter is not suitable for friable composite particles which can be broken by mechanical forces. The structure of magnetic part of the second filter has been changed so as to strongly capture particles composed of fine particles weakly bound together which tend to break when captured. This uses a principle of assisted-capture in which coarse particles aid the capture of the fine fragments. The technique has the unfortunate consequence that the pressure drop across the filter rises faster as capture capture proceeds than the filter described previously. These filters have the following characteristics: (1) No external magnet is required. (2) No external power is required. (3) Small is size and portable. (4) Easily interchangeable. (5) Can be cleaned without demagnetising.

  8. Three-dimensional plasma transport in open chaotic magnetic fields. A computational assessment for tokamak edge layers

    International Nuclear Information System (INIS)

    Frerichs, Heinke Gerd

    2010-04-01

    The development of nuclear fusion as an alternative energy source requires the research on magnetically confined, high temperature plasmas. In particular, the quantification of plasma flows in the domain near exposed material surfaces of the plasma container by computer simulations is of key importance, both for guiding interpretation of present fusion experiments and for aiding the ongoing design activities for large future devices such as ITER, W7-X or the DEMO reactor. There is a large number of computational issues related to the physics of hot, fully ionized and magnetized plasmas near surfaces of the vacuum chamber. This thesis is dedicated to one particular such challenge, namely the numerical quantification of self-consistent kinetic neutral gas and plasma fluid flows in very complex 3D (partially chaotic) magnetic fields, in the absence of any common symmetries for plasma and neutral gas dynamics. Such magnetic field configurations are e.g. generated by externally applied magnetic perturbations at the plasma edge, and are of great interest for the control of particle and energy exhausts. In the present thesis the 3D edge plasma and neutral particle transport code EMC3-EIRENE is applied to two distinct configurations of open chaotic magnetic system: at the TEXTOR and DIII-D tokamaks. Improvements of the edge transport model and extensions of the transport code are presented, which have allowed such simulations for the first time for 3D scenarios at DIII-D with ITER similar plasmas. A strong 3D effect of the chaotic magnetic field on the DIII-D edge plasma is found and analyzed in detail. It is found that a pronounced striation pattern of target particle and heat fluxes at DIII-D can only be obtained up to a certain upper limiting level of anomalous cross-field transport. Hence, in comparison to experimental data, these findings allow to narrow down the range of this model parameter. One particular interest at TEXTOR is the achievement of a regime with

  9. Exact analytical modeling of magnetic vector potential in surface inset permanent magnet DC machines considering magnet segmentation

    Science.gov (United States)

    Jabbari, Ali

    2018-01-01

    Surface inset permanent magnet DC machine can be used as an alternative in automation systems due to their high efficiency and robustness. Magnet segmentation is a common technique in order to mitigate pulsating torque components in permanent magnet machines. An accurate computation of air-gap magnetic field distribution is necessary in order to calculate machine performance. An exact analytical method for magnetic vector potential calculation in surface inset permanent magnet machines considering magnet segmentation has been proposed in this paper. The analytical method is based on the resolution of Laplace and Poisson equations as well as Maxwell equation in polar coordinate by using sub-domain method. One of the main contributions of the paper is to derive an expression for the magnetic vector potential in the segmented PM region by using hyperbolic functions. The developed method is applied on the performance computation of two prototype surface inset magnet segmented motors with open circuit and on load conditions. The results of these models are validated through FEM method.

  10. The Maryland Centrifugal Experiment (MCX): Centrifugal Confinement and Velocity Shear Stabilization of Plasmas in Shaped Open Magnetic Systems

    International Nuclear Information System (INIS)

    Hassam, Adil; Ellis, Richard F.

    2012-01-01

    The Maryland Centrifugal Experiment (MCX) Project has investigated the concepts of centrifugal plasma confinement and stabilization of instabilities by velocity shear. The basic requirement is supersonic plasma rotation about a shaped, open magnetic field. Overall, the MCX Project attained three primary goals that were set out at the start of the project. First, supersonic rotation at Mach number up to 2.5 was obtained. Second, turbulence from flute interchange modes was found considerably reduced from conventional. Third, plasma pressure was contained along the field, as evidenced by density drops of x10 from the center to the mirror throats.

  11. Magnetic fields produced by rotating symmetrical bodies with homogeneous surface charge density

    International Nuclear Information System (INIS)

    Espejel-Morales, R; Murguía-Romero, G; Calles, A; Cabrera-Bravo, E; Morán-López, J L

    2016-01-01

    We present a numerical calculation for the stationary magnetic field produced by different rotating bodies with homogeneous and constant surface charge density. The calculation is done by superposing the magnetic field produced by a set of loops of current which mimic the magnetic field produced by belts of current defined by slices of fixed width. We consider the cases of a sphere, ellipsoids, open and closed cylinders and a combination of these in a dumbbell -like shell. We also plot their magnetic field lines using a technique that make use of the Runge–Kutta fourth-order method. Up to our knowledge, the case of closed cylinders was not calculated before. In contrast to previous results, we find that the magnetic field inside finite hollow bodies is homogeneous only in the case of a sphere. This is consequence of the fact that, for the sphere, the surface of any slice taken perpendicularly to the rotation axis, depends only on its thickness, like in the case of an infinite cylinder. (paper)

  12. The {open_quotes}first{close_quotes} problem

    Energy Technology Data Exchange (ETDEWEB)

    Holsinger, R.F.

    1995-02-01

    This paper describes the first magnet design problem that Klaus and the author worked on together. At the time, over 30 years ago, Klaus was working as a plasma physicist in the Controlled Thermonuclear Research (CTR) Group, and the author was assigned from the Mechanical Engineering Department to help with the design of experimental equipment for various research projects. Klaus` primary research program was to develop a {open_quotes}plasma gun{close_quotes} for injecting plasma into {open_quotes}mirror machines.{close_quotes} As described, the magnet design aspect of this plasma gun was a challenging task, and led to some innovations that were quite advanced at that time.

  13. Detection of magnetic field intensity gradient by homing pigeons (Columba livia in a novel "virtual magnetic map" conditioning paradigm.

    Directory of Open Access Journals (Sweden)

    Cordula V Mora

    Full Text Available It has long been thought that birds may use the Earth's magnetic field not only as a compass for direction finding, but that it could also provide spatial information for position determination analogous to a map during navigation. Since magnetic field intensity varies systematically with latitude and theoretically could also provide longitudinal information during position determination, birds using a magnetic map should be able to discriminate magnetic field intensity cues in the laboratory. Here we demonstrate a novel behavioural paradigm requiring homing pigeons to identify the direction of a magnetic field intensity gradient in a "virtual magnetic map" during a spatial conditioning task. Not only were the pigeons able to detect the direction of the intensity gradient, but they were even able to discriminate upward versus downward movement on the gradient by differentiating between increasing and decreasing intensity values. Furthermore, the pigeons typically spent more than half of the 15 second sampling period in front of the feeder associated with the rewarded gradient direction indicating that they required only several seconds to make the correct choice. Our results therefore demonstrate for the first time that pigeons not only can detect the presence and absence of magnetic anomalies, as previous studies had shown, but are even able to detect and respond to changes in magnetic field intensity alone, including the directionality of such changes, in the context of spatial orientation within an experimental arena. This opens up the possibility for systematic and detailed studies of how pigeons could use magnetic intensity cues during position determination as well as how intensity is perceived and where it is processed in the brain.

  14. open-quotes High magnetic fields in the USAclose quotes

    International Nuclear Information System (INIS)

    Campbell, L.J.; Parkin, D.M.; Crow, J.E.; Schneider-Muntau, H.J.; Sullivan, N.S.

    1994-01-01

    During the past thirty years research using high magnetic fields has technically evolved in the manner, but not the magnitude, of the so-called big science areas of particle physics, plasma physics, neutron scattering, synchrotron light scattering, and astronomy. Starting from the laboratories of individual researchers it moved to a few larger universities, then to centralized national facilities with research and maintenance staffs, and, finally, to joint international ventures to build unique facilities, as illustrated by the subject of this conference. To better understand the nature of this type of research and its societal justification it is helpful to compare it, in general terms, with the aforementioned big-science fields. High magnetic field research differs from particle physics, plasma physics, and astronomy in three respects: (1) It is generic research that cuts across a wide range of scientific disciplines in physics, chemistry, biology, medicine, and engineering; (2) It studies materials and processes that are relevant for a variety of technological applications and it gives insight into biological processes; (3) It has produced, at least, comparably significant results with incomparably smaller resources. Unlike neutron and synchrotron light scattering, which probe matter, high magnetic fields change the thermodynamic state of matter. This change of state is fundamental and independent of other state variables, such as pressure and temperature. After the magnetic field is applied, various techniques are then used to study the new state

  15. Survival Prediction in Patients Undergoing Open-Heart Mitral Valve Operation After Previous Failed MitraClip Procedures.

    Science.gov (United States)

    Geidel, Stephan; Wohlmuth, Peter; Schmoeckel, Michael

    2016-03-01

    The objective of this study was to analyze the results of open heart mitral valve operations for survival prediction in patients with previously unsuccessful MitraClip procedures. Thirty-three consecutive patients who underwent mitral valve surgery in our institution were studied. At a median of 41 days, they had previously undergone one to five futile MitraClip implantations. At the time of their operations, patients were 72.6 ± 10.3 years old, and the calculated risk, using the European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, was a median of 26.5%. Individual outcomes were recorded, and all patients were monitored postoperatively. Thirty-day mortality was 9.1%, and the overall survival at 2.2 years was 60.6%. Seven cardiac-related and six noncardiac deaths occurred. Univariate survival regression models demonstrated a significant influence of the following variables on survival: EuroSCORE II (p = 0.0022), preoperative left ventricular end-diastolic dimension (p = 0.0052), left ventricular ejection fraction (p = 0.0249), coronary artery disease (p = 0.0385), and severe pulmonary hypertension (p = 0.0431). Survivors showed considerable improvements in their New York Heart Association class (p < 0.0001), left ventricular ejection fraction (p = 0.0080), grade of mitral regurgitation (p = 0.0350), and mitral valve area (p = 0.0486). Survival after mitral repair was not superior to survival after replacement. Indications for surgery after failed MitraClip procedures must be considered with the greatest of care. Variables predicting postoperative survival should be taken into account regarding the difficult decision as to whether to operate or not. Our data suggest that replacement of the pretreated mitral valve is probably the more reasonable concept rather than complex repairs. When the EuroSCORE II at the time of surgery exceeds 30%, conservative therapy is advisable. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc

  16. The LOFAR Magnetism Key Science Project

    NARCIS (Netherlands)

    Anderson, James; Beck, Rainer; Bell, Michael; de Bruyn, Ger; Chyzy, Krzysztof; Eislöffel, Jochen; Enßlin, Torsten; Fletcher, Andrew; Haverkorn, Marijke; Heald, George; Horneffer, Andreas; Noutsos, Aris; Reich, Wolfgang; Scaife, Anna; the LOFAR collaboration, [No Value

    2012-01-01

    Measuring radio waves at low frequencies offers a new window to study cosmic magnetism, and LOFAR is the ideal radio telescope to open this window widely. The LOFAR Magnetism Key Science Project (MKSP) draws together expertise from multiple fields of magnetism science and intends to use LOFAR to

  17. Generation of high magnetic fields using superconducting magnets

    International Nuclear Information System (INIS)

    Kiyoshi, T.; Otsuka, A.; Kosuge, M.; Yuyama, M.; Nagai, H.; Matsumoto, F.

    2006-01-01

    High-field superconducting magnets have opened new frontiers for several kinds of applications, such as fusion reactors, particle accelerators, and nuclear magnetic resonance (NMR) spectrometers. The present record for the highest field in a fully superconducting state is 23.4 T. It was achieved with a combination of NbTi, Nb 3 Sn, and Bi-2212 conductors in 1999. Since high T c (critical temperature) superconductors (HTS) have sufficiently high critical current density even in excess of 30 T, they are promising for use as high-field superconducting magnets. However, several problems still remain to be resolved for practical applications, and the use of HTS coils will be limited to the inner part of a high-field magnet system in the near future. The required technologies to develop a high-field superconducting magnet with a field of up to 28 T have already been established. Such a magnet is certain to provide information to all leading research areas

  18. OpenShift cookbook

    CERN Document Server

    Gulati, Shekhar

    2014-01-01

    If you are a web application developer who wants to use the OpenShift platform to host your next big idea but are looking for guidance on how to achieve this, then this book is the first step you need to take. This is a very accessible cookbook where no previous knowledge of OpenShift is needed.

  19. Analytical Calculation of the Magnetic Field distribution in a Flux-Modulated Permanent-Magnet Brushless Motor

    DEFF Research Database (Denmark)

    Zhang, Xiaoxu; Liu, Xiao; Chen, Zhe

    2015-01-01

    This paper presents a rapid approach to compute the magnetic field distribution in a flux-modulated permanent-magnet brushless motor. Partial differential equations are used to describe the magnet field behavior in terms of magnetic vector potentials. The whole computational domain is divided...... into several regions, i.e., magnet, air-gaps, slot-openings, and slots. The numerical solution could be obtained by applying the boundary constraints on the interfaces between these regions. The accuracy of the proposed analytical model is verified by comparing the no-load magnetic field and armature reaction...... magnetic field with those calculated by finite element method....

  20. On the Collisionless Asymmetric Magnetic Reconnection Rate

    Science.gov (United States)

    Liu, Yi-Hsin; Hesse, M.; Cassak, P. A.; Shay, M. A.; Wang, S.; Chen, L.-J.

    2018-04-01

    A prediction of the steady state reconnection electric field in asymmetric reconnection is obtained by maximizing the reconnection rate as a function of the opening angle made by the upstream magnetic field on the weak magnetic field (magnetosheath) side. The prediction is within a factor of 2 of the widely examined asymmetric reconnection model (Cassak & Shay, 2007, https://doi.org/10.1063/1.2795630) in the collisionless limit, and they scale the same over a wide parameter regime. The previous model had the effective aspect ratio of the diffusion region as a free parameter, which simulations and observations suggest is on the order of 0.1, but the present model has no free parameters. In conjunction with the symmetric case (Liu et al., 2017, https://doi.org/10.1103/PhysRevLett.118.085101), this work further suggests that this nearly universal number 0.1, essentially the normalized fast-reconnection rate, is a geometrical factor arising from maximizing the reconnection rate within magnetohydrodynamic-scale constraints.

  1. A new method to determine magnetic properties of the unsaturated-magnetized rotor of a novel gyro

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hai, E-mail: lihai7772006@126.com [MEMS Center, Harbin Institution of Technology, Harbin, 150001 (China); Liu, Xiaowei [MEMS Center, Harbin Institution of Technology, Harbin, 150001 (China); Key Laboratory of Micro-Systems and Micro-Structures Manufacturing, Ministry of Education, Harbin, 150001 (China); Dong, Changchun [School of Software, Harbin University of Science and Technology, Harbin, 150001 (China); Zhang, Haifeng [MEMS Center, Harbin Institution of Technology, Harbin, 150001 (China)

    2016-06-01

    A new method is proposed to determine magnetic properties of the unsaturated-magnetized, small and irregular shaped rotor of a novel gyro. The method is based on finite-element analysis and the measurements of the magnetic flux density distribution, determining magnetic parameters by comparing the magnetic flux intensity distribution differences between the modeling results under different parameters and the measured ones. Experiment on a N30 Grade NdFeB magnet shows that its residual magnetic flux density is 1.10±0.01 T, and coercive field strength is 801±3 kA/m, which are consistent with the given parameters of the material. The method was applied to determine the magnetic properties of the rotor of the gyro, and the magnetic properties acquired were used to predict the open-loop gyro precession frequency. The predicted precession frequency should be larger than 12.9 Hz, which is close to the experimental result 13.5 Hz. The result proves that the method is accurate in estimating the magnetic properties of the rotor of the gyro. - Highlights: • A new method to determine the magnetic properties of a gyro’s rotor is proposed. • The method is based on FEA and magnetic flux density distributions near magnets. • The result is determined by the distribution and values of all the measured points. • Using the result, the open-loop gyro precession frequency is precisely predicted.

  2. A new method to determine magnetic properties of the unsaturated-magnetized rotor of a novel gyro

    International Nuclear Information System (INIS)

    Li, Hai; Liu, Xiaowei; Dong, Changchun; Zhang, Haifeng

    2016-01-01

    A new method is proposed to determine magnetic properties of the unsaturated-magnetized, small and irregular shaped rotor of a novel gyro. The method is based on finite-element analysis and the measurements of the magnetic flux density distribution, determining magnetic parameters by comparing the magnetic flux intensity distribution differences between the modeling results under different parameters and the measured ones. Experiment on a N30 Grade NdFeB magnet shows that its residual magnetic flux density is 1.10±0.01 T, and coercive field strength is 801±3 kA/m, which are consistent with the given parameters of the material. The method was applied to determine the magnetic properties of the rotor of the gyro, and the magnetic properties acquired were used to predict the open-loop gyro precession frequency. The predicted precession frequency should be larger than 12.9 Hz, which is close to the experimental result 13.5 Hz. The result proves that the method is accurate in estimating the magnetic properties of the rotor of the gyro. - Highlights: • A new method to determine the magnetic properties of a gyro’s rotor is proposed. • The method is based on FEA and magnetic flux density distributions near magnets. • The result is determined by the distribution and values of all the measured points. • Using the result, the open-loop gyro precession frequency is precisely predicted.

  3. Thermodynamic properties of open noncritical string in external electromagnetic field

    International Nuclear Information System (INIS)

    Lichtzier, I.M.; Odintsov, S.D.; Bytsenko, A.A.

    1991-01-01

    We investigate the thermodynamics of open noncritical string (charged and neutral) in an external constant magnetic field. The free energy and Hagedorn temperature are calculated. It is shown that Hagedorn temperature is the same as in the absence of constant magnetic field. We present also the expressions for the free energy and Hagedorn temperature of the neutral open noncritical string in an external constant electromagnetic field. In this case Hagedorn temperature depends on the external electric field. (author)

  4. Detection of Magnetic Field Intensity Gradient by Homing Pigeons (Columba livia) in a Novel “Virtual Magnetic Map” Conditioning Paradigm

    Science.gov (United States)

    Mora, Cordula V.; Bingman, Verner P.

    2013-01-01

    It has long been thought that birds may use the Earth's magnetic field not only as a compass for direction finding, but that it could also provide spatial information for position determination analogous to a map during navigation. Since magnetic field intensity varies systematically with latitude and theoretically could also provide longitudinal information during position determination, birds using a magnetic map should be able to discriminate magnetic field intensity cues in the laboratory. Here we demonstrate a novel behavioural paradigm requiring homing pigeons to identify the direction of a magnetic field intensity gradient in a “virtual magnetic map” during a spatial conditioning task. Not only were the pigeons able to detect the direction of the intensity gradient, but they were even able to discriminate upward versus downward movement on the gradient by differentiating between increasing and decreasing intensity values. Furthermore, the pigeons typically spent more than half of the 15 second sampling period in front of the feeder associated with the rewarded gradient direction indicating that they required only several seconds to make the correct choice. Our results therefore demonstrate for the first time that pigeons not only can detect the presence and absence of magnetic anomalies, as previous studies had shown, but are even able to detect and respond to changes in magnetic field intensity alone, including the directionality of such changes, in the context of spatial orientation within an experimental arena. This opens up the possibility for systematic and detailed studies of how pigeons could use magnetic intensity cues during position determination as well as how intensity is perceived and where it is processed in the brain. PMID:24039812

  5. The role of geomagnetic cues in green turtle open sea navigation.

    Directory of Open Access Journals (Sweden)

    Simon Benhamou

    Full Text Available BACKGROUND: Laboratory and field experiments have provided evidence that sea turtles use geomagnetic cues to navigate in the open sea. For instance, green turtles (Chelonia mydas displaced 100 km away from their nesting site were impaired in returning home when carrying a strong magnet glued on the head. However, the actual role of geomagnetic cues remains unclear, since magnetically treated green turtles can perform large scale (>2000 km post-nesting migrations no differently from controls. METHODOLOGY/PRINCIPAL FINDINGS: In the present homing experiment, 24 green turtles were displaced 200 km away from their nesting site on an oceanic island, and tracked, for the first time in this type of experiment, with Global Positioning System (GPS, which is able to provide much more frequent and accurate locations than previously used tracking methods. Eight turtles were magnetically treated for 24-48 h on the nesting beach prior to displacement, and another eight turtles had a magnet glued on the head at the release site. The last eight turtles were used as controls. Detailed analyses of water masses-related (i.e., current-corrected homing paths showed that magnetically treated turtles were able to navigate toward their nesting site as efficiently as controls, but those carrying magnets were significantly impaired once they arrived within 50 km of home. CONCLUSIONS/SIGNIFICANCE: While green turtles do not seem to need geomagnetic cues to navigate far from the goal, these cues become necessary when turtles get closer to home. As the very last part of the homing trip (within a few kilometers of home likely depends on non-magnetic cues, our results suggest that magnetic cues play a key role in sea turtle navigation at an intermediate scale by bridging the gap between large and small scale navigational processes, which both appear to depend on non-magnetic cues.

  6. Rare earth permanent magnet with easy magnetization

    International Nuclear Information System (INIS)

    Kim, A.S.; Camp, F.E.

    1998-01-01

    Rare earth permanent magnets have high energy products and coercivities, and thus the volume miniaturization of magnetic devices has been possible with improved magnetic performance. Although the high energy products of these rare earth permanent magnets provide substantial advantages for magnetic design and application, the strong magnetic force of the magnetized magnets makes assembly difficult. Therefore, a special device is needed to assemble the magnetized magnets. On the other hand, unmagnetized magnets are assembled and then they are magnetized. The assembled magnets are generally more difficult to magnetize than unassembled magnets because a much less effective magnetic field may be applied to them. This is particularly true for the rare earth permanent magnets because they usually need a much higher magnetic field to be fully magnetized than alnico or ferrite magnets. To obtain optimum magnetic properties, the required minimum magnetizing fields for SmCo 5 , Sm 2 TM 17 and Nd 2 Fe 14 B magnets were reported as 25-30 kOe, 45-60 kOe and 25-30 kOe, respectively. If the required magnetizing field for full saturation could be lowered, the effective utilization of magnetic properties would be maximized and the magnetic design option could be expanded with reduced restrictions. To meet this demand, we have sought to lower the field required for full magnetic saturation, and found that an increase in Dy content in R-(Fe,Co,Cu)-B type magnets lowers the field required for full saturation as well as improves the temperature stability. By increasing the H ci with Dy addition from 14 kOe to 24 and 34 kOe, the field required for full magnetic saturation decreases from about 20 to 15 and 10 kOe, respectively. This dual benefit will open up new application areas with more freedom for magnet design options. The mechanism for the lower magnetizing fields will be discussed. (orig.)

  7. Open magnetic surfaces and resonant topology in the separatrix-dominated boundary region of the W7-AS stellarator

    International Nuclear Information System (INIS)

    Sardei, F.; Grigull, P.; Herre, G.; Kisslinger, J.; Richter-Gloetzl, M.

    1993-01-01

    The boundary of W7-AS for ι ≅ 1/3 is defined by the contact with two up-down limiters. Smooth flux surfaces extend deep into the SOL, and the limiters map into large-size flux bundles of homogeneous connection lengths. For this topology, a radial 1D transport model has been developed and used to derive radial profiles and density scaling of the diffusion coefficient in the limiter dominated SOL. At ι ≥ 0.5, the boundary topology is totally different and exhibits open, divertor-like field structures which are responsible for highly non-homogeneous recycling and wall load distributions. A comprehensive understanding of the plasma transport and recycling in this region is needed, for example, to optimize passive and active methods of particle and impurity control, to clarify the effects of the boundary conditions on the main plasma performance and to explore the divertor potential of W7-AS. Evaluation and correlation of local experimental data are more difficult in this open topology, as it cannot be parametrized by standard magnetic coordinates. (author) 5 refs., 6 figs

  8. Magnetic-seeding filtration

    International Nuclear Information System (INIS)

    Ying, T.Y.; Chin, C.J.; Lu, S.C.; Yiacoumi, S.

    1997-10-01

    Magnetic-seeding filtration consists of two steps: heterogeneous particle flocculation of magnetic and nonmagnetic particles in a stirred tank and high-gradient magnetic filtration (HGMF). The effects of various parameters affecting magnetic-seeding filtration (HGMF). The effects of various parameters affecting magnetic seeding filtration are theoretically and experimentally investigated. A trajectory model that includes hydrodynamic resistance, van der Waals, and electrostatic forces is developed to calculate the flocculation frequency in a turbulent-shear regime. Fractal dimension is introduced to simulate the open structure of aggregates. A magnetic-filtration model that consists of trajectory analysis, a particle build-up model, a breakthrough model, and a bivariate population-balance model is developed to predict the breakthrough curve of magnetic-seeding filtration. A good agreement between modeling results and experimental data is obtained. The results show that the model developed in this study can be used to predict the performance of magnetic-seeding filtration without using empirical coefficients or fitting parameters. 35 refs., 7 figs., 1 tab

  9. Reflection of Alfven waves at an open magnetopause

    International Nuclear Information System (INIS)

    Cao, F.; Kan, J.R.

    1990-01-01

    Reflection of an Alfven wave incident on an open magnetopause form the magnetospheric side is examined. An open magnetopause, whose structure is different from the standard rotational discontinuity, is assumed to be a parameterized discontinuity with a nonzero normal field component. When an Alfven wave is incident on the open magnetopause, reflected and transmitted waves are generated. The emanating waves can be analyzed using linearized MHD conservation relations across the magnetopause, together with Snell's law. Under the assumption that the magnetic fields on the two sides of the open magnetopause are coplanar with the normal direction of the magnetopause, the governing equations are solved numerically. The results show that the electric fields of emanating Alfven waves depend mainly on the number density and the magnetic field jumps across the magnetopause. Under conditions representing the open magnetopause, it turns out that the open magnetopause behaves like a near perfect reflector. The corresponding reflection coefficient for the wave electric field can be approximated by R E = E r /E i ∼ -1 as has been deduced by Kan and Sun (1985) based on physical arguments. In other words, the solar wind flow is more or less unchanged by the loading effect of the Alfven wave incident on the magnetopause from the magnetospheric side. Therefore, under the assumptions of the model, the open magnetopause can be viewed as a constant voltage source

  10. Thermo-hydraulic Quench Propagation at the LHC Superconducting Magnet String

    CERN Document Server

    Rodríguez-Mateos, F; Serio, L

    1998-01-01

    The superconducting magnets of the LHC are protected by heaters and cold by-pass diodes. If a magnet quenches, the heaters on this magnet are fired and the magnet chain is de-excited in about two minu tes by opening dump switches in parallel to a resistor. During the time required for the discharge, adjacent magnets might quench due to thermo-hydraulic propagation in the helium bath and/or heat con duction via the bus bar. The number of quenching magnets depends on the mechanisms for the propagation. In this paper we report on quench propagation experiments from a dipole magnet to an adjacent ma gnet. The mechanism for the propagation is hot helium gas expelled from the first quenching magnet. The propagation changes with the pressure opening settings of the quench relief valves.

  11. Fluid simulation of the conduction phase of the plasma erosion opening switch

    International Nuclear Information System (INIS)

    Grossmann, J.M.; Mosher, D.; Ottinger, P.F.

    1987-01-01

    The conduction phase of the plasma erosion openings switch (PEOS) is studied using a 1 1/2-D electromagnetic two-fluid code. The focus of this work is on understanding how two effects, a current-limiting model of electron emission, and the magnetic insulation of electrons at the cathode, determine current conduction in the plasma. Simulations are performed in the parameter regimes of the Gamble I, POP, and PBFA II pulsed power generators, and previous low-density, short-rise time simulations of the PEOS. Fluid code results are compared to a 1-D analytic theory and to the Gamble I and POP experiments. Good agreement between theory and simulation, but mixed agreement between simulation and experiment is found. Experimental Β-field measurements on POP show weaker j x Β compression than the simulation. Current penetration and plasma current channels qualitatively similar to experimental observation are found in the Gamble I regime. However, magnetic insulation of electrons emitted from the cathode bunches the electron flow into narrower current channels than observed experimentally. In several cases, the presence of an electron-scattering or energy-loss mechanism near the cathode must be invoked to overcome magnetic insulation and widen the current channels

  12. Modified BEM calculations on magnetic systems

    International Nuclear Information System (INIS)

    Christoph, V.; Toepfer, J.

    1998-01-01

    A modified boundary element method is presented for the calculation of 3d magnetic fields of magnetic systems including any permanent and soft magnetic materials as well as current distributions. Using an automatic mesh generation inside the magnetic bodies the method is especially suited for the investigation of open air gap systems. The influence of eddy currents on the magnetisation process can be investigated. For illustration, the flux concentration by pole pieces and the generation of magnetic stripe structures in magnetic thick films by pulse fields are considered. (orig.)

  13. Magnetic patches in internetwork areas

    NARCIS (Netherlands)

    de Wijn, A.G.; Rutten, R.J.|info:eu-repo/dai/nl/074143662; Haverkamp, E.M.W.P.; Sütterlin, P.

    2006-01-01

    We present a study of internetwork magnetic elements that appear as bright points in G-band (photosphere) and Ca II H (low chromosphere) image sequences from the Dutch Open Telescope. Many bright points appear intermittently in groups of long-lived structures that we call “magnetic patches”. We

  14. The magnet database system

    International Nuclear Information System (INIS)

    Ball, M.J.; Delagi, N.; Horton, B.; Ivey, J.C.; Leedy, R.; Li, X.; Marshall, B.; Robinson, S.L.; Tompkins, J.C.

    1992-01-01

    The Test Department of the Magnet Systems Division of the Superconducting Super Collider Laboratory (SSCL) is developing a central database of SSC magnet information that will be available to all magnet scientists at the SSCL or elsewhere, via network connections. The database contains information on the magnets' major components, configuration information (specifying which individual items were used in each cable, coil, and magnet), measurements made at major fabrication stages, and the test results on completed magnets. These data will facilitate the correlation of magnet performance with the properties of its constituents. Recent efforts have focused on the development of procedures for user-friendly access to the data, including displays in the format of the production open-quotes travelerclose quotes data sheets, standard summary reports, and a graphical interface for ad hoc queues and plots

  15. Magnetic Satellite Missions and Data

    DEFF Research Database (Denmark)

    Olsen, Nils; Kotsiaros, Stavros

    2011-01-01

    Although the first satellite observations of the Earth’s magnetic field were already taken more than 50 years ago, continuous geomagnetic measurements from space are only available since 1999. The unprecedented time-space coverage of this recent data set opened revolutionary new possibilities...... for exploring the Earth’s magnetic field from space. In this chapter we discuss characteristics of satellites measuring the geomagnetic field and report on past, present and upcoming magnetic satellite missions. We conclude with some basics about space magnetic gradiometry as a possible path for future...... exploration of Earth’s magnetic field with satellites....

  16. Simulation of plasma erosion opening switches

    International Nuclear Information System (INIS)

    Mason, R.J.; Jones, M.E.

    1988-01-01

    The plasma erosion opening switch (PEOS) has been studied with the ANTHEM and ISIS implicit simulation codes. The switch consists of plasma fill injected into a transmission line. The plasma initially shorts out the circuit, but eventually it is removed by self-electrical forces, allowing for the delivery of energy to a load. ANTHEM models the plasma by multiple fluids with electron inertia retained, or by the particle-in-cell (PIC) technique. ISIS is an optimized PIC code. Both codes determine electric and magnetic fields by the implicit moment method. This allows for the study of long time full-switch behavior with simulational zone sizes and time steps that are large compared to a Debye length and plasma period, respectively. Thus, the authors have modeled switch behavior at densities ranging from 5 x 10 11 to 5 x 10 14 electrons/cm -3 over drive pulses ranging from 5 to 250 ns. Here, the magnetic field rose linearly from zero to 0.8 or 3.0 Tesla. Switch gaps spanned from 1.0 to 8.0 cm, and inner radii ranged from 0.5 to 20.0 cm. Opening dynamics is shown to depend sensitively on the assumed electron emission thresholds at the cathode, and on the effective conductivity of the anode. The particle simulations predict broader current channels than the multi-fluid calculations - reasons for this are discussed. The effect of numerical diffusion in implicit simulations is examined. The response to realistic load impedances (10 Ohms for Sandia National Laboratory's PBFA II accelerator) of the opening characteristics is described. Advantages from plasma fill near the load are investigated. The action of preset initial magnetic fields aligned with the power flow, and of trigger magnetic fields for controlled removal of the plasma is discussed

  17. Waste water purification by magnetic separation technique using HTS bulk magnet system

    International Nuclear Information System (INIS)

    Oka, T.; Kanayama, H.; Tanaka, K.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Terasawa, T.; Itoh, Y.; Yabuno, R.

    2009-01-01

    We have investigated the feasibility of strong magnetic field generators composed of the high temperature superconducting (HTS) bulk magnet systems to the magnetic separation techniques for the waste water including thin emulsion bearing the cutting oil. Two types of the strong field generators were prepared by the face-to-face HTS bulk magnet systems, which emit the magnetic field density of 1 and 2 T in the open spaces between the magnetic poles activated by the pulsed field magnetization and the field cooling methods, respectively. A couple of water channels containing iron balls were settled in the strong field to trap the magnetized flocks in the waste water. The separation ratios of flocks containing 200 ppm magnetite powder were evaluated with respect to the flow rates of the waste water. The performances of bulk magnet system have kept showing values of around 100% until the flowing rate reached up to 18 l/min. This suggests that the magnetic separation by using bulk magnets is effective for the practical water purification systems.

  18. Superconductivity and electronic structure of superpure niobium. 3. Magnetoconductivity and magnetic breakdown in large magnetic fields

    International Nuclear Information System (INIS)

    Alekseevskij, N.E.; Nizhankovskij, V.I.; Bertel', K.-X.

    1976-01-01

    Measurements have been of electric conductivity and magnetoresistance of niobium monocrystals with various orientations in helium and hydrogen temperature regions in steady-state magnetic fields of up to 175 ke. At helium temperatures the resistance is shown to be proportional to the square of temperature. A significant longitudinal magnetoresistance of niobium has been established, depending on the sample orientation. Its initiation is attributed to the open nature of the niobium Fermi surface. As a result of studying the lateral magnetoresistance in fields of up to 92 ke, a stereographic projection of niobium open directions has been constructed. Open trajectories exist both in two-dimensional regions around the directions [100] and [111] and along the symmetry lines. Studies conducted in fields of up to 175 ke have revealed a magnetic break- own leading to the conversion of the open trajectories to the closed ones. A comprehensive picture of the magnetic break-down in niobium has been obtained, and on the basis of the coherent model an expression has been derived describing the impact of this break-down on the resistance. Comparison between experimental and theoretical dependences of the magnetoresistance on the field characteristics has provided the value of the break-down field H 0 =280 ke

  19. Resonant and nonresonant magnetic scattering (invited)

    International Nuclear Information System (INIS)

    McWhan, D.B.; Hastings, J.B.; Kao, C.; Siddons, D.P.

    1992-01-01

    The tunability and the polarization of synchrotron radiation open up new possibilities for the study of magnetism. Studies on magnetic materials performed at the National Synchrotron Light Source are reviewed, and they fall into four areas: structure, evolution of magnetic order, separation of L and S, and resonance effects. In the vicinity of atomic absorption edges, the Faraday effect, magnetic circular dichroism, and resonant magnetic scattering are all related resonance effects which measure the spin-polarized density of states. The production and analysis of polarized beams are discussed in the context of the study of magnetism with synchrotron radiation

  20. The Relationship of Lumbar Multifidus Muscle Morphology to Previous, Current, and Future Low Back Pain

    DEFF Research Database (Denmark)

    Hebert, Jeffrey J; Kjær, Per; Fritz, Julie M

    2014-01-01

    of LBP after five and nine years.Summary of Background Data. Although low back pain (LBP) is a major source of disease burden, the biologic determinants of LBP are poorly understood.Methods. Participants were 40-year-old adults randomly sampled from a Danish population and followed-up at ages 45 and 49....... At each time point, participants underwent magnetic resonance imaging and reported ever having had LBP, LBP in the previous year, non-trivial LBP in the previous year, or a history of pain radiating into the legs. Pixel intensity and frequencies from T1-weighted magnetic resonance images identified...

  1. Anthem simulation studies of the plasma opening switch

    International Nuclear Information System (INIS)

    Mason, R.J.

    1993-01-01

    For a deeper understanding of the physical processes governing the Plasma Opening Switch (POS) the authors use the ANTHEM 2D implicit simulation code to study: (1) ion dynamical effects on electrohydrodynamic (EHD) waves propagating along steep density interfaces in the switch plasmas. At radial interfaces where the density jumps toward the anode, these waves can drive a finger of magnetic field into the plasma toward the load. Ion dynamics can open the rear of such fingers into a wedge-like density gap. Then: (2) they examine ion effects in uniform switch plasmas. These first develop potential hill structures at the drive edge of the cathode from the competition between electron velocity advection and EHD magnetic exclusion waves. Magnetic pressure gradients at the hill periphery and EHD effects then establish a density gap propagating along the cathode with radial electron emission from its tip. Similar results are obtained under both multi-fluid and PIC modeling on the plasma components

  2. Photon Splitting in a Strong Magnetic Field: Recalculation and Comparison with Previous Calculations

    International Nuclear Information System (INIS)

    Adler, S.L.; Schubert, C.

    1996-01-01

    We recalculate the amplitude for photon splitting in a strong magnetic field below the pair production threshold, using the world line path integral variant of the Bern-Kosower formalism. Numerical comparison (using programs that we have made available for public access on the Internet) shows that the results of the recalculation are identical to the earlier calculations of Adler and later of Stoneham, and to the recent recalculation by Baier, Milstein, and Shaisultanov. copyright 1996 The American Physical Society

  3. Impact of previous open renal surgery on the outcomes of subsequent percutaneous nephrolithotomy: a meta-analysis.

    Science.gov (United States)

    Hu, Henglong; Lu, Yuchao; Cui, Lei; Zhang, Jiaqiao; Zhao, Zhenyu; Qin, Baolong; Wang, Yufeng; Wang, Qing; Wang, Shaogang

    2016-04-28

    The aim of this study was to systematically compare the perioperative outcomes of percutaneous nephrolithotomy in patients with or without previous ipsilateral open renal surgery (POS). Systematic searches of the PubMed, Web of Science and Cochrane Library databases were used to identify relevant studies, and, following literature screening and data extraction, a meta-analysis was performed. 17 retrospective cohort studies involving 4833 procedures (4784 patients) were included. No statistically significant differences were observed between patients with or without POS in terms of supracostal access; single/multiple tracts; metal dilator need; time required to access the collecting system; fluoroscopic duration; demand for analgesics; hospital stay; final stone-free rate; and risk of developing certain complications (eg, fever, haemorrhage, haemo/hydro/pneumothorax, blood transfusion, urinary tract infection and sepsis) as well as regarding the risk of total complications. Patients with POS, however, had a greater drop in haemoglobin (weighted mean difference (WMD), 1.78 g/L; 95% CI 1.09 to 2.47; pPOS also had a lower initial stone-free rate (RR, 0.96; 95% CI 0.92 to 0.99; p=0.007) and more secondary treatment (RR, 1.61; 95% CI 1.09 to 2.37; p=0.02). Sensitivity analysis produced comparable results except for differences in operative time and initial stone-free rate, which did, however, prove to be statistically insignificant (p=0.16 and 0.69, respectively). Current evidence suggests that percutaneous nephrolithotomy in patients with POS is associated with a significantly greater drop in haemoglobin, higher risk of requiring angiographic embolisation and auxiliary procedures, potentially longer operative time, and lower initial stone-free rate than percutaneous nephrolithotomy in patients without POS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Magnetic forces and magnetized biomaterials provide dynamic flux information during bone regeneration.

    Science.gov (United States)

    Russo, Alessandro; Bianchi, Michele; Sartori, Maria; Parrilli, Annapaola; Panseri, Silvia; Ortolani, Alessandro; Sandri, Monica; Boi, Marco; Salter, Donald M; Maltarello, Maria Cristina; Giavaresi, Gianluca; Fini, Milena; Dediu, Valentin; Tampieri, Anna; Marcacci, Maurilio

    2016-03-01

    The fascinating prospect to direct tissue regeneration by magnetic activation has been recently explored. In this study we investigate the possibility to boost bone regeneration in an experimental defect in rabbit femoral condyle by combining static magnetic fields and magnetic biomaterials. NdFeB permanent magnets are implanted close to biomimetic collagen/hydroxyapatite resorbable scaffolds magnetized according to two different protocols . Permanent magnet only or non-magnetic scaffolds are used as controls. Bone tissue regeneration is evaluated at 12 weeks from surgery from a histological, histomorphometric and biomechanical point of view. The reorganization of the magnetized collagen fibers under the effect of the static magnetic field generated by the permanent magnet produces a highly-peculiar bone pattern, with highly-interconnected trabeculae orthogonally oriented with respect to the magnetic field lines. In contrast, only partial defect healing is achieved within the control groups. We ascribe the peculiar bone regeneration to the transfer of micro-environmental information, mediated by collagen fibrils magnetized by magnetic nanoparticles, under the effect of the static magnetic field. These results open new perspectives on the possibility to improve implant fixation and control the morphology and maturity of regenerated bone providing "in site" forces by synergically combining static magnetic fields and biomaterials.

  5. Ulysses Observations of the Magnetic Connectivity between CMEs and the Sun

    Science.gov (United States)

    Riley, Pete; Gosling, J. T.; Crooker, N. U.

    2004-01-01

    We have investigated the magnetic connectivity of coronal mass ejections (CMEs) to the Sun using Ulysses observations of suprathermal electrons at various distances between 1 AU and 5.2 AU. Drawing on ideas concerning the eruption and evolution of CMEs, we had anticipated that there might be a tendency for CMEs to contain progressively more open field lines, as reconnection back at the Sun either opened or completely disconnected previously closed field lines threading the CMEs. Our results, however, did not yield any discernible trend. By combining the potential contribution of CMEs to the heliospheric flux with the observed build-up of flux during the course of the solar cycle we also derive a lower limit for the reconnection rate of CMEs that is sufficient to avoid the "flux catastrophe" paradox. This rate is well below our threshold of detectability.

  6. Superconducting open-gradient magnetic separation for the pretreatment of radioactive or mixed waste vitrification feeds. 1997 annual progress report

    International Nuclear Information System (INIS)

    Cicero-Herman, C.A.; Ritter, J.A.

    1997-01-01

    'Vitrification has been selected as a final waste form technology in the US for long-term storage of high-level radioactive wastes (HLW). However, a foreseeable problem during vitrification in some waste feed streams lies in the presence of elements (e.g., transition metals) in the HLW that may cause instabilities in the final glass product. The formation of spinel compounds, such as Fe 3 O 4 and FeCrO 4 , results in glass phase separation and reduces vitrifier lifetime, and durability of the final waste form. A superconducting open gradient magnetic separation (OGMS) system maybe suitable for the removal of the deleterious transition elements (e.g. Fe, Co, and Ni) and other elements (lanthanides) from vitrification feed streams due to their ferromagnetic or paramagnetic nature. The OGMS systems are designed to deflect and collect paramagnetic minerals as they interact with a magnetic field gradient. This system has the potential to reduce the volume of HLW for vitrification and ensure a stable product. In order to design efficient OGMS and High gradient magnetic separation (HGMS) processes, a fundamental understanding of the physical and chemical properties of the waste feed streams is required. Using HLW simulant and radioactive fly ash and sludge samples from the Savannah River Technology Center, Rocky Flats site, and the Hanford reservation, several techniques were used to characterize and predict the separation capability for a superconducting OGMS system.'

  7. Design and analysis of magnetic shield for 650 MHz SCRF cavity

    International Nuclear Information System (INIS)

    Thakur, Vanshree; Jain, Vikas; Das, S.; Shinde, R.S.; Joshi, S.C.

    2015-01-01

    Five-cell, 650 MHz Superconducting RF (SCRF) cavity is being developed at RRCAT for the Injector Linac of proposed ISNS project. The SCRF cavity needs to be shielded effectively from earth magnetic field. The external magnetic field can cause magnetic field trapping that limits the performance of SCRF cavity. The allowable limit of earth magnetic field in the cavity surface is < 10 mG. The magnetic shielding analysis carried out for 650 MHz dressed SCRF cavity is presented in this paper. For axial magnetic field shielding analysis, 2-D code PANDIRA has been used. A 2-D axisymmetric geometry (cylinder of Cryoperm10 sheet with 460 mm diameter of various thickness and 1100 mm length) has been modelled and analyzed in the presence of 240 mG external axial magnetic field. The influence of partial opening of 120 mm diameter at both ends of the cylinder on magnetic field pattern inside the shielded region has been evaluated. The transverse magnetic shielding analysis in the presence of 500 mG transverse external field has been carried out using OPERA 3D code. The flux leakage through the major openings for cavity supports, ports on the shield is investigated and accordingly the openings are designed to minimize the leakage. Inference of material thickness on the magnetic shielding for reducing magnetic field below specified limit has been investigated. Details of design and analysis of magnetic shield for SCRF cavity will be discussed in this paper. (author)

  8. Sharing Lessons-Learned on Effective Open Data, Open-Source Practices from OpenAQ, a Global Open Air Quality Community.

    Science.gov (United States)

    Hasenkopf, C. A.

    2017-12-01

    Increasingly, open data, open-source projects are unearthing rich datasets and tools, previously impossible for more traditional avenues to generate. These projects are possible, in part, because of the emergence of online collaborative and code-sharing tools, decreasing costs of cloud-based services to fetch, store, and serve data, and increasing interest of individuals to contribute their time and skills to 'open projects.' While such projects have generated palpable enthusiasm from many sectors, many of these projects face uncharted paths for sustainability, visibility, and acceptance. Our project, OpenAQ, is an example of an open-source, open data community that is currently forging its own uncharted path. OpenAQ is an open air quality data platform that aggregates and universally formats government and research-grade air quality data from 50 countries across the world. To date, we make available more than 76 million air quality (PM2.5, PM10, SO2, NO2, O3, CO and black carbon) data points through an open Application Programming Interface (API) and a user-customizable download interface at https://openaq.org. The goal of the platform is to enable an ecosystem of users to advance air pollution efforts from science to policy to the private sector. The platform is also an open-source project (https://github.com/openaq) and has only been made possible through the coding and data contributions of individuals around the world. In our first two years of existence, we have seen requests for data to our API skyrocket to more than 6 million datapoints per month, and use-cases as varied as ingesting data aggregated from our system into real-time models of wildfires to building open-source statistical packages (e.g. ropenaq and py-openaq) on top of the platform to creating public-friendly apps and chatbots. We will share a whirl-wind trip through our evolution and the many lessons learned so far related to platform structure, community engagement, organizational model type

  9. Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

    Science.gov (United States)

    Walsworth, Ronald L.

    2004-01-01

    We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

  10. Evidence for {open_quotes}magnetic rotation{close_quotes} in nuclei: New results on the M1-bands of {sup 198,199}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Clark, R.M. [Lawrence Berkeley National Lab., CA (United States)

    1996-12-31

    Lifetimes of states in four of the M1-bands in {sup 198,199}Pb have been determined through a Doppler Shift Attenuation Method measurement performed using the Gammasphere array. The deduced B(M1) values, which are a sensitive probe of the underlying mechanism for generating these sequences, show remarkable agreement with Tilted Axis Cranking (TAC) calculations. Evidence is also presented for the possible termination of the bands. The results represent clear evidence for a new concept in nuclear excitations: {open_quote}magnetic rotation{close_quote}.

  11. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  12. Circular swimming in mice after exposure to a high magnetic field.

    Science.gov (United States)

    Houpt, Thomas A; Houpt, Charles E

    2010-06-16

    There is increasing evidence that exposure to high magnetic fields of 4T and above perturbs the vestibular system of rodents and humans. Performance in a swim test is a sensitive test of vestibular function. In order to determine the effect of magnet field exposure on swimming in mice, mice were exposed for 30 min within a 14.1T superconducting magnet and then tested at different times after exposure in a 2-min swim test. As previously observed in open field tests, mice swam in tight counter-clockwise circles when tested immediately after magnet exposure. The counter-clockwise orientation persisted throughout the 2-min swim test. The tendency to circle was transient, because no significant circling was observed when mice were tested at 3 min or later after magnet exposure. However, mice did show a decrease in total distance swum when tested between 3 and 40 min after magnet exposure. The decrease in swimming distance was accompanied by a pronounced postural change involving a counter-clockwise twist of the pelvis and hindlimbs that was particularly severe in the first 15s of the swim test. Finally, no persistent difference from sham-exposed mice was seen in the swimming of magnet-exposed mice when tested 60 min, 24h, or 96 h after magnet exposure. This suggests that there is no long-lasting effect of magnet exposure on the ability of mice to orient or swim. The transient deficits in swimming and posture seen shortly after magnet exposure are consistent with an acute perturbation of the vestibular system by the high magnetic field. (c) 2010 Elsevier Inc. All rights reserved.

  13. Exotic magnetic states in Pauli-limited superconductors.

    Science.gov (United States)

    Kenzelmann, M

    2017-03-01

    Magnetism and superconductivity compete or interact in complex and intricate ways. Here we review the special case where novel magnetic phenomena appear due to superconductivity, but do not exist without it. Such states have recently been identified in unconventional superconductors. They are different from the mere coexistence of magnetic order and superconductivity in conventional superconductors, or from competing magnetic and superconducting phases in many materials. We describe the recent progress in the study of such exotic magnetic phases, and articulate the many open questions in this field.

  14. Large Superconducting Magnet Systems

    CERN Document Server

    Védrine, P.

    2014-07-17

    The increase of energy in accelerators over the past decades has led to the design of superconducting magnets for both accelerators and the associated detectors. The use of Nb−Ti superconducting materials allows an increase in the dipole field by up to 10 T compared with the maximum field of 2 T in a conventional magnet. The field bending of the particles in the detectors and generated by the magnets can also be increased. New materials, such as Nb$_{3}$Sn and high temperature superconductor (HTS) conductors, can open the way to higher fields, in the range 13–20 T. The latest generations of fusion machines producing hot plasma also use large superconducting magnet systems.

  15. Large Superconducting Magnet Systems

    Energy Technology Data Exchange (ETDEWEB)

    Védrine, P [Saclay (France)

    2014-07-01

    The increase of energy in accelerators over the past decades has led to the design of superconducting magnets for both accelerators and the associated detectors. The use of Nb−Ti superconducting materials allows an increase in the dipole field by up to 10 T compared with the maximum field of 2 T in a conventional magnet. The field bending of the particles in the detectors and generated by the magnets can also be increased. New materials, such as Nb3Sn and high temperature superconductor (HTS) conductors, can open the way to higher fields, in the range 13–20 T. The latest generations of fusion machines producing hot plasma also use large superconducting magnet systems.

  16. Feasibility of diffusion-weighted magnetic resonance imaging in patients with juvenile idiopathic arthritis on 1.0-T open-bore MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barendregt, Anouk M.; Nusman, Charlotte M. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Hemke, Robert; Lavini, Cristina; Maas, Mario [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); Amiras, Dimitri [Imperial College Healthcare NHS Trust, Radiology Department, St. Mary' s Hospital, Paddington, London (United Kingdom); Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands)

    2015-12-15

    To evaluate the feasibility of non-invasive diffusion-weighted imaging (DWI) of the knee of children with juvenile idiopathic arthritis (JIA) and, further, to analyze the apparent diffusion coefficient (ADC) levels to distinguish synovium from effusion. Standard magnetic resonance imaging of the knee including post-contrast imaging was obtained in eight patients (mean age, 12 years 8 months, five females) using an open-bore magnetic resonance imaging system (1.0 T). In addition, axially acquired echo-planar DWI datasets (b-values 0, 50, and 600) were prospectively obtained and the diffusion images were post-processed into ADC{sub 50-600} maps. Two independent observers selected a region of interest (ROI) for both synovium and effusion using aligned post-contrast images as landmarks. Mann-Whitney U test was performed to compare ADC synovium and ADC effusion. DWI was successfully obtained in all patients. When data of both observers was combined, ADC synovium was lower than ADC effusion in the ROI in seven out of eight patients (median, 1.92 x 10{sup -3} mm{sup 2}/s vs. 2.40 x 10{sup -3} mm{sup 2}/s, p = 0.006, respectively). Similar results were obtained when the two observers were analyzed separately (observer 1: p = 0.006, observer 2: p = 0.04). In this pilot study, on a patient-friendly 1.0-T open-bore MRI, we demonstrated that DWI may potentially be a feasible non-invasive imaging technique in children with JIA. We could differentiate synovium from effusion in seven out of eight patients based on the ADC of synovium and effusion. However, to select synovium and effusion on DWI, post-contrast images were still a necessity. (orig.)

  17. Depressed emission between magnetic arcades near a sunspot

    Science.gov (United States)

    Ryabov, B. I.; Shibasaki, K.

    The locations of the depressed emission in microwaves, EUV and soft X-rays are compared with each other and with the location of the plasma outflow in the active region (AR) 8535 on the Sun. We found that two open-field regions overlap the regions of depressed emission near the AR's sunspot. These two open-field regions are simulated with the potential-field source-surface (PFSS) model under radial distances of RSS = 1.8 R⊙ and RSS = 2.5 R⊙. Each open-field region is located between the arcades of the loops of the same magnetic polarity. The former open-field region covers the region of the plasma outflow, which is thus useful for the tests on connection to the heliosphere. The utmost microwave depression of the intensity in the ordinary mode (the Very Large Array 15 GHz observations) also overlaps the region of the plasma outflow and thus indicates this outflow. The lasting for eight days depression in soft X-rays and the SOHO EIT 2.84× 10-8 m images are attributed to the evacuation of as hot coronal plasma as T≥ 2× 106 K from the extended in height (``open") magnetic structures. We conclude that the AR 8535 presents the sunspot atmosphere affected by the large-scale magnetic fields.

  18. Electronically rotated and translated field-free line generation for open bore magnetic particle imaging.

    Science.gov (United States)

    Top, Can Barış; Ilbey, Serhat; Güven, Hüseyin Emre

    2017-12-01

    We propose a coil arrangement for open bore field-free line (FFL) magnetic particle imaging (MPI) system, which is suitable for accessing the subject from the sides. The purpose of this study is twofold, to show that the FFL can be rotated and translated electronically in a volume of interest with this arrangement and to analyze the current, voltage and power requirements for a 1 T/m gradient human sized scanner for a 200 mm diameter × 200 mm height cylindrical field of view (FOV). We used split coils side by side with alternating current directions to generate a field-free line. Employing two of these coil groups, one of which is rotated 90 degrees with respect to the other, a rotating FFL was generated. We conducted numerical simulations to show the feasibility of this arrangement for three-dimensional (3D) electronical scan of the FFL. Using simulations, we obtained images of a two-dimensional (2D) in silico dot phantom for a human size scanner with system matrix-based reconstruction. Simulations showed that the FFL can be generated and rotated in one plane and can be translated in two axes, allowing for 3D imaging of a large subject with the proposed arrangement. Human sized scanner required 63-215 kW power for the selection field coils to scan the focus inside the FOV. The proposed setup is suitable for FFL MPI imaging with an open bore configuration without the need for mechanical rotation, which is preferable for clinical usage in terms of imaging time and patient access. Further studies are necessary to determine the limitations imposed by peripheral nerve stimulation, and to optimize the system parameters and the sequence design. © 2017 American Association of Physicists in Medicine.

  19. Extraction of remanent magnetization from magnetization vector inversions of airborne full tensor magnetic gradiometry data

    Science.gov (United States)

    Queitsch, M.; Schiffler, M.; Stolz, R.; Meyer, M.; Kukowski, N.

    2017-12-01

    Measurements of the Earth's magnetic field are one of the most used methods in geophysical exploration. The ambiguity of the method, especially during modeling and inversion of magnetic field data sets, is one of its biggest challenges. Additional directional information, e.g. gathered by gradiometer systems based on Superconducting Quantum Interference Devices (SQUIDs), will positively influence the inversion results and will thus lead to better subsurface magnetization models. This is especially beneficial, regarding the shape and direction of magnetized structures, especially when a significant remanent magnetization of the underlying sources is present. The possibility to separate induced and remanent contributions to the total magnetization may in future also open up advanced ways for geological interpretation of the data, e.g. a first estimation of diagenesis processes. In this study we present the results of airborne full tensor magnetic gradiometry (FTMG) surveys conducted over a dolerite intrusion in central Germany and the results of two magnetization vector inversions (MVI) of the FTMG and a conventional total field anomaly data set. A separation of the two main contributions of the acquired total magnetization will be compared with information of the rock magnetization measured on orientated rock samples. The FTMG inversion results show a much better agreement in direction and strength of both total and remanent magnetization compared to the inversion using only total field anomaly data. To enhance the separation process, the application of additional geophysical methods, i.e. frequency domain electromagnetics (FDEM), in order to gather spatial information of subsurface rock susceptibility will also be discussed. In this approach, we try to extract not only information on subsurface conductivity but also the induced magnetization. Using the total magnetization from the FTMG data and the induced magnetization from the FDEM data, the full separation of

  20. Synthesis of magnetic microtubes decorated with nanowires and cells

    Science.gov (United States)

    Pomar, C. Diaz; Martinho, H.; Ferreira, F. F.; Goia, T. S.; Rodas, A. C. D.; Santos, S. F.; Souza, J. A.

    2018-04-01

    Antiferromagnetic and ferrimagnetic microtubes decorated with nanowires have been obtained during thermal oxidation process, which was assisted by in situ electrical resistivity measurements. The synthesis route including heat treatment and electrical current along with growth mechanism are presented. This simple method and the ability to tune in the magnetic moment of the obtained microtubes going from a nonmagnetic-like to a large magnetization saturation open an avenue for interesting applications. In vitro experiments involving adherence, migration, and proliferation of fibroblasts cell culture on the surface of the microtubes indicated the absence of cytotoxicity for this material. We have also calculated both torque and driving magnetic force for these microtubes with nanowires and cells as a function of external magnetic field gradient which were found to be robust opening the possibility for magnetic bio micro-robot device fabrication and application in biotechnology.

  1. Rare earth permanent magnets

    International Nuclear Information System (INIS)

    Higuchi, Akira

    1992-01-01

    This paper is a review of the new technologies for Nd-Fe-B magnets, their markets and future perspectives. This type of magnet is a product approaching the ideal magnet, and is based upon the development history of two previous generations of Sm-Co alloy systems and the recent progress on physical and metallurgical research. (orig.)

  2. Bi-magnetic microwires: a novel family of materials with controlled magnetic behavior

    International Nuclear Information System (INIS)

    Pirota, K.R.; Provencio, M.; Garcia, K.L.; Escobar-Galindo, R.; Mendoza Zelis, P.; Hernandez-Velez, M.; Vazquez, M.

    2005-01-01

    A novel technique involving combined sputtering and electroplating procedures has been recently developed to deposit metallic (magnetic or not) nano and microlayer tubes onto glass-coated amorphous magnetic microwires to enable the tailoring of their magnetic behavior. Here, after introducing the general aspects of that technique, we present the latest results on a new family of two-phase magnetic samples: bi-magnetic multilayer microwires. They consist of a magnetically soft nucleus (typically a Fe or Co base amorphous microwire, coated by Pyrex layer) onto which a 30 nm thick Au layer is first sputtered followed by the electroplating of a harder microlayer, namely Co x Ni (1- x ) layer, with x controlled by the current density during electrodeposition whose micrometric thickness is also controlled by plating time. The hysteresis loops present a two-step reversal process typical of two-phase magnetic material. The magnetization reversal of the soft nucleus and the harder layer takes place at around 1 Oe and up to about 200 Oe, respectively. The presence of sputtered and electroplated layers induces significant stresses in the soft magnetic nucleus that modify its magnetization easy axis. This technique allowing us the tailoring of the magnetic behavior of multilayer magnetic microwires opens new possibilities for applying these novel materials as sensing elements in various devices

  3. Fourier decomposition of segmented magnets with radial magnetization in surface-mounted PM machines

    Science.gov (United States)

    Tiang, Tow Leong; Ishak, Dahaman; Lim, Chee Peng

    2017-11-01

    This paper presents a generic field model of radial magnetization (RM) pattern produced by multiple segmented magnets per rotor pole in surface-mounted permanent magnet (PM) machines. The magnetization vectors from either odd- or even-number of magnet blocks per pole are described. Fourier decomposition is first employed to derive the field model, and later integrated with the exact 2D analytical subdomain method to predict the magnetic field distributions and other motor global quantities. For the assessment purpose, a 12-slot/8-pole surface-mounted PM motor with two segmented magnets per pole is investigated by using the proposed field model. The electromagnetic performances of the PM machines are intensively predicted by the proposed magnet field model which include the magnetic field distributions, airgap flux density, phase back-EMF, cogging torque, and output torque during either open-circuit or on-load operating conditions. The analytical results are evaluated and compared with those obtained from both 2D and 3D finite element analyses (FEA) where an excellent agreement has been achieved.

  4. Magnetic Field Measurements of the GOLIATH Magnet in EHN1

    CERN Document Server

    Rosenthal, Marcel; Chatzidaki, Panagiota; Margraf, Rachel; Wilkens, Henric; Bergsma, Felix; Giudici, Pierre-Ange; CERN. Geneva. ATS Department

    2018-01-01

    This note describes the measurement campaign of the magnetic field of the GOLIATH magnet conducted in 2017. It documents the applied measurement procedure and the consecutive analysis of the recorded data. The shape of the magnetic field along the beam axis is discussed and compared with a previous measurement taken in the 1980s. Overall a very good agreement of both data sets is observed. The integrated vertical magnetic field is obtained by analytical descriptions fitted to the data. Additionally, the influence of different configurations of the power converters, as for example in the case of a differ- ent powering scheme of the upper and lower coil of the GOLIATH magnet, on the magnetic field are discussed.

  5. Study on magnetic separation system using high Tc superconducting bulk magnets for water purification technique

    International Nuclear Information System (INIS)

    Oka, T; Kanayama, H; Tanaka, K; Fukui, S; Ogawa, J; Sato, T; Ooizumi, M; Yamaguchi, M; Yokoyama, K; Noto, K

    2009-01-01

    The application of superconducting bulk magnets to the magnetic separation techniques has been investigated for the Mn-bearing waste water drained from the university laboratories. The research has been conducted in comparison with the electromagnets, and the cryo-cooled superconducting solenoid magnet. The separation ratios of ferrite precipitates including Mn element in the waste slurry were estimated by means of the high gradient magnetic separation method with ferromagnetic iron filters in the water channel and open gradient magnetic separation without them. As the magnetic force acting on the particles is given by the product of a magnetization of particles and a gradient of magnetic field, and a superconducting bulk magnet shows a sharp gradient of the magnetic field on the surface, the performances of the bulk magnet system were almost equivalent to those of the superconducting solenoid magnet with wide bore with respect to the magnetic separation ratios. The separation ratios for Mn have reached over 80 % for HGMS and 10 % for OGMS under the flow rates less than 3 liter/min.

  6. Cogging Torque Reduction by Slot-Opening Shift for Permanent Magnet Machines

    DEFF Research Database (Denmark)

    Liu, Ting; Huang, Shoudao; Gao, Jian

    2013-01-01

    In this paper, an effective cogging torque reduction method based on shifting the slot-openings is presented. Stator teeth are divided into groups and proper slot-opening shift is applied for each group. The cogging torque can then be greatly reduced while the back-EMF waveforms remain symmetrical...

  7. Structural and magnetic characterization of three tetranuclear Cu(II) complexes with face-sharing-dicubane/double-open-cubane like core framework

    Science.gov (United States)

    Paul, Aparup; Bertolasi, Valerio; Figuerola, Albert; Manna, Subal Chandra

    2017-05-01

    Three novel tetranuclear copper(II) complexes namely [Cu4(L1)4]•2(dmf) (1), [Cu4(L1)4] (2) and [Cu4(L2)2(HL2)2(H2O)2]•2(ClO4)·6(H2O) (3) (H2L1, (E)-2-((1-hydroxybutan-2-ylimino)methyl)phenol; H2L2, (E)-2-((1-hydroxybutan-2-ylimino)methyl)-6-methoxyphenol)) were synthesized from the self-assembly of copper(II) perchlorate and the tridentate Schiff base ligands. The structural determination reveals that complex 1 crystallizes in the monoclinic system with space group C2/c, whereas both the complexes 2 and 3 crystallize in the triclinic system with space group P-1. Complexes 1 and 2 possess face-sharing dicubane core, on the other hand complex 3 has double open cubane core structure. The copper(II) ions in the cubane core are in distorted square planar geometries, and weak π…π and C-H…π interactions lead to formation of a 2D supramolecular architecture for complexes 1 and 2. At room temperature complexes 1, 2 and 3, exhibit fluorescence with a quantum yield (Φs) of 0.47, 0.49 and 0.38, respectively. Variable temperature magnetic susceptibility measurements in the range 2-300 K indicate an overall weak antiferromagnetic exchange coupling in all complexes. The PHI program was used to study their magnetic behaviour. In agreement with their face-sharing dicubane structure, a Hamiltonian of the type H =- J1(S1S2+S1S2'+S1'S2+S1'S2') - J2S1S1', where S1 = S1' = S2 = S2' = SCu =1/2, was used for studying complexes 1 and 2. Simulations performed suggest magnetic exchange constants with values close to J1 =-20 cm-1 and J2 =0 cm-1 for these complexes. On the other hand, the spin Hamiltonian H =- J1(S1S4+S2S3) - J2(S1S3+S2S4) - J3S1S2, where S1 = S2 = S3 = S4 = SCu =1/2, was used to study the magnetic behaviour of the double open cubane core of complex 3 and a good agreement between the experimental and simulated results was found by using the parameters g1 = g2 =2.20, g3 = g4 =2.18, J1 =-36 cm-1, J2 =-44 cm-1 and J3 =0 cm-1.

  8. Measurement of the surface field on open magnetic samples by the extrapolation method

    Czech Academy of Sciences Publication Activity Database

    Perevertov, Oleksiy

    2005-01-01

    Roč. 76, - (2005), 104701/1-104701/7 ISSN 0034-6748 R&D Projects: GA ČR(CZ) GP202/04/P010; GA AV ČR(CZ) 1QS100100508 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic field measurement * extrapolation * air gaps * magnetic permeability Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.235, year: 2005

  9. Properties enhancement and recoil loop characteristics for hot deformed nanocrystalline NdFeB permanent magnets

    International Nuclear Information System (INIS)

    Liu, Z. W.; Huang, Y. L.; Hu, S. L.; Zhong, X. C.; Yu, H. Y.; Gao, X. X.

    2013-01-01

    Nanocrystalline NdFeB magnets were prepared by spark plasma sintering (SPS) and SPS followed by HD using melt spun ribbons as the starting materials. The microstructure of SPSed and HDed magnets were analyzed. The effects of process including temperature and compression ratio on the microstructure and properties were investigated. High magnetic properties were obtained in anisotropic HDed magnets. The combination of Zn and Dy additions was successfully employed to improve the coercivity and thermal stability of the SPSed magnets. Open recoil loops were found in these magnets with Nd-rich composition and without soft magnetic phase for the first time. The relationship between the recoil loops and microstructure for SPS and HD NdFeB magnets were investigated. The investigations showed that the magnetic properties of SPS+HDed magnets are related to the extent of the aggregation of Nd-rich phase, which was formed during HD due to existence of porosity in SPSed precursor. Large local demagnetization fields induced by the Nd-rich phase aggregation leads to the open loops and significantly reduced the coercivity. By reducing the recoil loop openness, the magnetic properties of HDed NdFeB magnets were successfully improved. (author)

  10. Superconductivity : Controlling magnetism

    NARCIS (Netherlands)

    Golubov, Alexandre Avraamovitch; Kupriyanov, Mikhail Yu.

    Manipulation of the magnetic state in spin valve structures by superconductivity has now been achieved, opening a new route for the development of ultra-fast cryogenic memories. Spintronics is a rapidly developing field that allows insight into fundamental spin-dependent physical properties and the

  11. Easy to open? Exploring the 'openability' of hospital food and beverage packaging by older adults.

    Science.gov (United States)

    Bell, Alison F; Walton, Karen L; Tapsell, Linda C

    2016-03-01

    Food is increasingly a packaged commodity, both in the community and in institutionalised settings such as hospitals, where many older people are malnourished. Previous research with patients aged over 65 years in NSW public hospitals identified difficulties opening milk, water, juices, cereal and tetra packs. The aim of this paper was to assess the ability of well older people living in the community to open food and beverage items routinely used in NSW hospitals in order to gain further insights into the older person/pack interaction and the role of hand and finger strength in pack opening. A sample of 40 older people in good health aged over 65 years from 3 community settings participated in the study. The attempts at pack opening were observed, the time taken to open the pack was measured and the correlation between grip and pinch strengths with opening times was determined. Tetra packs, water bottles, cereal, fruit cups, desserts, biscuits and cheese portions appeared to be the most difficult food products to open. Ten percent of the sample could not open the water bottles and 39% could not open cheese portions. The results were consistent with the previous research involving hospitalised older adults, adding emphasis to the conclusion that food and beverage packaging can be a potential barrier to adequate nutrition when particular types of packaged products are used in hospitals or the community. The ageing population is rapidly becoming a larger and more important group to consider in the provision of goods and services. Designers, manufacturers and providers of food and beverage products need to consider the needs and abilities of these older consumers to ensure good 'openability' and promote adequate nutritional intakes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Lattice Boltzmann simulation of natural convection heat transfer in an open enclosure filled with Cu–water nanofluid in a presence of magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Ahmed Kadhim, E-mail: ahmedkadhim7474@gmail.com [Department of Mechanical Engineering, College of Engineering, Babylon University, Babylon City (Iraq); Ashorynejad, Hamid Reza; Shikholeslami, Mohsen [Faculty of Mechanical Engineering, Babol University of Technology, Babol, Mazandaran, Islamic Republic of Iran (Iran, Islamic Republic of); Sivasankaran, S. [Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur 50603 (Malaysia)

    2014-03-15

    Highlights: • Convection very strong when Ra is high and Ha = 0. • Isotherms smooth when Ra is low and Ha is high. • Maximum stream function increases by adding nano-particle. • Flow circulation decreases when magnetic orientation angle increases. • Nusselt number ratio increases when Ra increases. - Abstract: In this paper magneto hydrodynamic (MHD) natural convection flow of Cu–water nanofluid in an open enclosure is investigated numerically using lattice Boltzmann method (LBM) scheme. The effective thermal conductivity and viscosity of nanofluid are calculated by the Maxwell–Garnetts (MG) and Brinkman models, respectively. In addition, the MDF model was used for simulating the effect of uniform magnetic field. The influence of pertinent parameters such as Hartmann number, nanoparticle volume fraction, Rayleigh number and the inclination of magnetic field on the flow and heat transfer characteristics have been examined. The results indicate that the absolute values of stream function decline significantly by increasing Hartmann numbers while these values rise by increasing Rayleigh numbers. Moreover, the results show that the solid volume fraction has a significant influence on stream function and heat transfer, depending on the value of Hartmann and Rayleigh numbers.

  13. Evidence for open field lines in Jupiter's magnetosphere

    Science.gov (United States)

    Goertz, C. K.; Randall, B. A.; Thomsen, M. F.; Jones, D. E.; Smith, E. J.

    1976-01-01

    A model for the night-side Jovian magnetic field is derived partly on the basis of theoretical considerations and partly on the basis of the magnetic-field data obtained during the outbound leg of the path of Pioneer 10. This model can explain the observed sawtooth modulation of energetic particle fluxes in terms of closed and open field lines that cannot contain the particles. The model is applicable only to the Jovian magnetotail.

  14. Micromagnetic study of skyrmion stability in confined magnetic structures with perpendicular anisotropy

    Science.gov (United States)

    Novak, R. L.; Garcia, F.; Novais, E. R. P.; Sinnecker, J. P.; Guimarães, A. P.

    2018-04-01

    Skyrmions are emerging topological spin structures that are potentially revolutionary for future data storage and spintronics applications. The existence and stability of skyrmions in magnetic materials is usually associated to the presence of the Dzyaloshinskii-Moriya interaction (DMI) in bulk magnets or in magnetic thin films lacking inversion symmetry. While some methods have already been proposed to generate isolated skyrmions in thin films with DMI, a thorough study of the conditions under which the skyrmions will remain stable in order to be manipulated in an integrated spintronic device are still an open problem. The stability of such structures is believed to be a result of ideal combinations of perpendicular magnetic anisotropy (PMA), DMI and the interplay between geometry and magnetostatics. In the present work we show some micromagnetic results supporting previous experimental observations of magnetic skyrmions in spin-valve stacks with a wide range of DMI values. Using micromagnetic simulations of cobalt-based disks, we obtain the magnetic ground state configuration for several values of PMA, DMI and geometric parameters. Skyrmion numbers, corresponding to the topological charge, are calculated in all cases and confirm the occurrence of isolated, stable, axially symmetric skyrmions for several combinations of DMI and anisotropy constant. The stability of the skyrmions in disks is then investigated under magnetic field and spin-polarized current, in finite temperature, highlighting the limits of applicability of these spin textures in spintronic devices.

  15. The antecedents of open business models : an exploratory study of incumbent firms

    OpenAIRE

    Frankenberger, Karolin; Weiblen, Tobias; Gassmann, Oliver

    2014-01-01

    Firms engage increasingly in open business models. While most research has previously focused on typologies or challenges of open business models, their specific antecedents have not been studied so far. We use data from eight open business model cases to explore this question and identify five main antecedents of open business models: (1) business model inconsistency, (2) need to create and capture new value, (3) previous experience with collaboration, (4) open business model patterns, and ...

  16. Outlook for the use of microsecond plasma opening switches to generate high-power nanosecond current pulses

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Maslennikov, D.D.; Ushakov, A.G.

    2006-01-01

    Paper deals with a phenomenon of current breaking in a conducting plasma volume of plasma opening switchers with a nanosecond time of energy initiation and their application in high-power generators. One determined the conditions to ensure megavolt voltages under the erosion mode making use of external applied magnetic field to ensure magnetic insulation of gap of plasma opening switchers. One studied the peculiar features of application of plasma opening switchers under 5-6 MV voltages to ensure X-ray and gamma-radiation pulses [ru

  17. Magnetic resonance instrumentation

    International Nuclear Information System (INIS)

    Bell, R.A.

    1987-01-01

    Magnetic resonance (MR), while opening new vistas to diagnostic medicine, utilizes equipment that is unfamiliar to most clinicians. Beyond learning to cope with new terms, such as spin-echo, T1, T2, and spin density, health care professionals are faced with the inclusion of magnetic and radiofrequency effects in their facilities produced by a complex array of devices. It is the purpose of this chapter to outline the components of an MR imaging system, to discuss their functions, and to note the variations in equipment commercially available

  18. Magnetic field shimming of a permanent magnet using a combination of pieces of permanent magnets and a single-channel shim coil for skeletal age assessment of children.

    Science.gov (United States)

    Terada, Y; Kono, S; Ishizawa, K; Inamura, S; Uchiumi, T; Tamada, D; Kose, K

    2013-05-01

    We adopted a combination of pieces of permanent magnets and a single-channel (SC) shim coil to shim the magnetic field in a magnetic resonance imaging system dedicated for skeletal age assessment of children. The target magnet was a 0.3-T open and compact permanent magnet tailored to the hand imaging of young children. The homogeneity of the magnetic field was first improved by shimming using pieces of permanent magnets. The residual local inhomogeneity was then compensated for by shimming using the SC shim coil. The effectiveness of the shimming was measured by imaging the left hands of human subjects and evaluating the image quality. The magnetic resonance images for the child subject clearly visualized anatomical structures of all bones necessary for skeletal age assessment, demonstrating the usefulness of combined shimming. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. THE EFFECT OF MAGNETIC TOPOLOGY ON THERMALLY DRIVEN WIND: TOWARD A GENERAL FORMULATION OF THE BRAKING LAW

    Energy Technology Data Exchange (ETDEWEB)

    Réville, Victor; Brun, Allan Sacha; Strugarek, Antoine; Pinto, Rui F. [Laboratoire AIM, DSM/IRFU/SAp, CEA Saclay, F-91191 Gif-sur-Yvette Cedex (France); Matt, Sean P., E-mail: victor.reville@cea.fr, E-mail: sacha.brun@cea.fr, E-mail: s.matt@exeter.ac.uk, E-mail: strugarek@astro.umontreal.ca, E-mail: rui.pinto@obspm.fr [Department of Physics and Astronomy, University of Exeter, Stocker Road, Exeter EX4 4SB (United Kingdom)

    2015-01-10

    Stellar wind is thought to be the main process responsible for the spin down of main-sequence stars. The extraction of angular momentum by a magnetized wind has been studied for decades, leading to several formulations for the resulting torque. However, previous studies generally consider simple dipole or split monopole stellar magnetic topologies. Here we consider, in addition to a dipolar stellar magnetic field, both quadrupolar and octupolar configurations, while also varying the rotation rate and the magnetic field strength. Sixty simulations made with a 2.5D cylindrical and axisymmetric set-up, and computed with the PLUTO code, were used to find torque formulations for each topology. We further succeed to give a unique law that fits the data for every topology by formulating the torque in terms of the amount of open magnetic flux in the wind. We also show that our formulation can be applied to even more realistic magnetic topologies, with examples of the Sun in its minimum and maximum phases as observed at the Wilcox Solar Observatory, and of a young K-star (TYC-0486-4943-1) whose topology has been obtained by Zeeman-Doppler Imaging.

  20. Invariance of the magnetic behavior and AMI in ferromagnetic biphase films with distinct non-magnetic metallic spacers

    Energy Technology Data Exchange (ETDEWEB)

    Silva, E.F. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Gamino, M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Andrade, A.M.H. de [Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Vázquez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Correa, M.A. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Bohn, F., E-mail: felipebohn@fisica.ufrn.br [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)

    2017-02-01

    We investigate the quasi-static magnetic, magnetotransport, and dynamic magnetic properties in ferromagnetic biphase films with distinct non-magnetic metallic spacer layers. We observe that the nature of the non-magnetic metallic spacer material does not have significant influence on the overall biphase magnetic behavior, and, consequently, on the magnetotransport and dynamic magnetic responses. We focus on the magnetoimpedance effect and verify that the films present asymmetric magnetoimpedance effect. Moreover, we explore the possibility of tuning the linear region of the magnetoimpedance curves around zero magnetic field by varying the probe current frequency in order to achieve higher sensitivity values. The invariance of the magnetic behavior and the asymmetric magnetoimpedance effect in ferromagnetic biphase films with distinct non-magnetic metallic spacers place them as promising candidates for probe element and open possibilities to the development of lower-cost high sensitivity linear magnetic field sensor devices.

  1. Wireless Sensing System Using Open-circuit, Electrically-conductive Spiral-trace Sensor

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2013-01-01

    A wireless sensing system includes a sensor made from an electrical conductor shaped to form an open-circuit, electrically-conductive spiral trace having inductance and capacitance. In the presence of a time-varying magnetic field, the sensor resonates to generate a harmonic response having a frequency, amplitude and bandwidth. A magnetic field response recorder wirelessly transmits the time-varying magnetic field to the sensor and wirelessly detects the sensor's response frequency, amplitude and bandwidth.

  2. DOWNWARD CATASTROPHE OF SOLAR MAGNETIC FLUX ROPES

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Quanhao; Wang, Yuming; Hu, Youqiu; Liu, Rui, E-mail: zhangqh@mail.ustc.edu.cn [CAS Key Laboratory of Geospace Environment, Department of Geophysics and Planetary Sciences, University of Science and Technology of China, Hefei 230026 (China)

    2016-07-10

    2.5-dimensional time-dependent ideal magnetohydrodynamic (MHD) models in Cartesian coordinates were used in previous studies to seek MHD equilibria involving a magnetic flux rope embedded in a bipolar, partially open background field. As demonstrated by these studies, the equilibrium solutions of the system are separated into two branches: the flux rope sticks to the photosphere for solutions at the lower branch but is suspended in the corona for those at the upper branch. Moreover, a solution originally at the lower branch jumps to the upper, as the related control parameter increases and reaches a critical value, and the associated jump is here referred to as an upward catastrophe. The present paper advances these studies in three aspects. First, the magnetic field is changed to be force-free; the system still experiences an upward catastrophe with an increase in each control parameter. Second, under the force-free approximation, there also exists a downward catastrophe, characterized by the jump of a solution from the upper branch to the lower. Both catastrophes are irreversible processes connecting the two branches of equilibrium solutions so as to form a cycle. Finally, the magnetic energy in the numerical domain is calculated. It is found that there exists a magnetic energy release for both catastrophes. The Ampère's force, which vanishes everywhere for force-free fields, appears only during the catastrophes and does positive work, which serves as a major mechanism for the energy release. The implications of the downward catastrophe and its relevance to solar activities are briefly discussed.

  3. DOWNWARD CATASTROPHE OF SOLAR MAGNETIC FLUX ROPES

    International Nuclear Information System (INIS)

    Zhang, Quanhao; Wang, Yuming; Hu, Youqiu; Liu, Rui

    2016-01-01

    2.5-dimensional time-dependent ideal magnetohydrodynamic (MHD) models in Cartesian coordinates were used in previous studies to seek MHD equilibria involving a magnetic flux rope embedded in a bipolar, partially open background field. As demonstrated by these studies, the equilibrium solutions of the system are separated into two branches: the flux rope sticks to the photosphere for solutions at the lower branch but is suspended in the corona for those at the upper branch. Moreover, a solution originally at the lower branch jumps to the upper, as the related control parameter increases and reaches a critical value, and the associated jump is here referred to as an upward catastrophe. The present paper advances these studies in three aspects. First, the magnetic field is changed to be force-free; the system still experiences an upward catastrophe with an increase in each control parameter. Second, under the force-free approximation, there also exists a downward catastrophe, characterized by the jump of a solution from the upper branch to the lower. Both catastrophes are irreversible processes connecting the two branches of equilibrium solutions so as to form a cycle. Finally, the magnetic energy in the numerical domain is calculated. It is found that there exists a magnetic energy release for both catastrophes. The Ampère's force, which vanishes everywhere for force-free fields, appears only during the catastrophes and does positive work, which serves as a major mechanism for the energy release. The implications of the downward catastrophe and its relevance to solar activities are briefly discussed.

  4. Plastic debris in the open ocean

    OpenAIRE

    Cózar, Andrés; Echevarría, Fidel; González-Gordillo, J. Ignacio; Irigoien, Xabier; Úbeda, Bárbara; Hernández-León, Santiago; Palma, Álvaro T.; Navarro, Sandra; García-de-Lomas, Juan; Ruiz, Andrea; Fernández-de-Puelles, María L.; Duarte, Carlos M.

    2014-01-01

    There is a rising concern regarding the accumulation of floating plastic debris in the open ocean. However, the magnitude and the fate of this pollution are still open questions. Using data from the Malaspina 2010 circumnavigation, regional surveys, and previously published reports, we show a worldwide distribution of plastic on the surface of the open ocean, mostly accumulating in the convergence zones of each of the five subtropical gyres with comparable density. Howeve...

  5. The influence of electrical resistivity, magnetic field strength, boundary conditions, and injection conditions on the behavior of the magnetically injected plasma in the PBFA-II opening switch

    International Nuclear Information System (INIS)

    Watrous, J.J.; Frese, M.H.

    1993-01-01

    The Plasma Opening Switch used on PBFA-II uses a source plasma which is injected into the inter-electrode gap along the field lines of a modest-strength applied poloidal magnetic field. The distribution of this plasma within the gap plays an important role in the behavior of the switch. Knowledge of this distribution is critical for performing relevant switch calculations and for interpreting experimental data. In the work reported here, the influence on that distribution of the plasma electrical resistivity, the applied magnetic field strength, and the boundary and injection conditions have been investigated with the 2 1/2-dimensional magnetohydrodynamics simulation code, MACH2. The injected plasma has density in the 10 14 cm -3 range and temperature in the several eV range. In this parameter regime, the classical collision time scale is on the order of 10 ns, which, when compared to the 100 ns time scale of the inflowing plasma, means that the plasma is classically collisionless. However, mechanisms other than classical collisions are likely to contribute to electrical resistivity. The authors have investigated the effect of an anomalous resistivity which scales with the plasma frequency, varying the scaling from the electron plasma frequency to the ion plasma frequency. They will compare these results with results based on the assumption of an ideal plasma, and discuss other anomalous resistivity models

  6. Magnetic memory of a single-molecule quantum magnet wired to a gold surface.

    Science.gov (United States)

    Mannini, Matteo; Pineider, Francesco; Sainctavit, Philippe; Danieli, Chiara; Otero, Edwige; Sciancalepore, Corrado; Talarico, Anna Maria; Arrio, Marie-Anne; Cornia, Andrea; Gatteschi, Dante; Sessoli, Roberta

    2009-03-01

    In the field of molecular spintronics, the use of magnetic molecules for information technology is a main target and the observation of magnetic hysteresis on individual molecules organized on surfaces is a necessary step to develop molecular memory arrays. Although simple paramagnetic molecules can show surface-induced magnetic ordering and hysteresis when deposited on ferromagnetic surfaces, information storage at the molecular level requires molecules exhibiting an intrinsic remnant magnetization, like the so-called single-molecule magnets (SMMs). These have been intensively investigated for their rich quantum behaviour but no magnetic hysteresis has been so far reported for monolayers of SMMs on various non-magnetic substrates, most probably owing to the chemical instability of clusters on surfaces. Using X-ray absorption spectroscopy and X-ray magnetic circular dichroism synchrotron-based techniques, pushed to the limits in sensitivity and operated at sub-kelvin temperatures, we have now found that robust, tailor-made Fe(4) complexes retain magnetic hysteresis at gold surfaces. Our results demonstrate that isolated SMMs can be used for storing information. The road is now open to address individual molecules wired to a conducting surface in their blocked magnetization state, thereby enabling investigation of the elementary interactions between electron transport and magnetism degrees of freedom at the molecular scale.

  7. Ellipsoids (v1.0): 3-D magnetic modelling of ellipsoidal bodies

    Science.gov (United States)

    Takahashi, Diego; Oliveira, Vanderlei C., Jr.

    2017-09-01

    A considerable amount of literature has been published on the magnetic modelling of uniformly magnetized ellipsoids since the second half of the nineteenth century. Ellipsoids have flexibility to represent a wide range of geometrical forms, are the only known bodies which can be uniformly magnetized in the presence of a uniform inducing field and are the only finite bodies for which the self-demagnetization can be treated analytically. This property makes ellipsoids particularly useful for modelling compact orebodies having high susceptibility. In this case, neglecting the self-demagnetization may strongly mislead the interpretation of these bodies by using magnetic methods. A number of previous studies consider that the self-demagnetization can be neglected for the case in which the geological body has an isotropic susceptibility lower than or equal to 0.1 SI. This limiting value, however, seems to be determined empirically and there has been no discussion about how this value was determined. In addition, the geoscientific community lacks an easy-to-use tool to simulate the magnetic field produced by uniformly magnetized ellipsoids. Here, we present an integrated review of the magnetic modelling of arbitrarily oriented triaxial, prolate and oblate ellipsoids. Our review includes ellipsoids with both induced and remanent magnetization, as well as with isotropic or anisotropic susceptibility. We also discuss the ambiguity between confocal ellipsoids with the same magnetic moment and propose a way of determining the isotropic susceptibility above which the self-demagnetization must be taken into consideration. Tests with synthetic data validate our approach. Finally, we provide a set of routines to model the magnetic field produced by ellipsoids. The routines are written in Python language as part of the Fatiando a Terra, which is an open-source library for modelling and inversion in geophysics.

  8. Ellipsoids (v1.0: 3-D magnetic modelling of ellipsoidal bodies

    Directory of Open Access Journals (Sweden)

    D. Takahashi

    2017-09-01

    Full Text Available A considerable amount of literature has been published on the magnetic modelling of uniformly magnetized ellipsoids since the second half of the nineteenth century. Ellipsoids have flexibility to represent a wide range of geometrical forms, are the only known bodies which can be uniformly magnetized in the presence of a uniform inducing field and are the only finite bodies for which the self-demagnetization can be treated analytically. This property makes ellipsoids particularly useful for modelling compact orebodies having high susceptibility. In this case, neglecting the self-demagnetization may strongly mislead the interpretation of these bodies by using magnetic methods. A number of previous studies consider that the self-demagnetization can be neglected for the case in which the geological body has an isotropic susceptibility lower than or equal to 0.1 SI. This limiting value, however, seems to be determined empirically and there has been no discussion about how this value was determined. In addition, the geoscientific community lacks an easy-to-use tool to simulate the magnetic field produced by uniformly magnetized ellipsoids. Here, we present an integrated review of the magnetic modelling of arbitrarily oriented triaxial, prolate and oblate ellipsoids. Our review includes ellipsoids with both induced and remanent magnetization, as well as with isotropic or anisotropic susceptibility. We also discuss the ambiguity between confocal ellipsoids with the same magnetic moment and propose a way of determining the isotropic susceptibility above which the self-demagnetization must be taken into consideration. Tests with synthetic data validate our approach. Finally, we provide a set of routines to model the magnetic field produced by ellipsoids. The routines are written in Python language as part of the Fatiando a Terra, which is an open-source library for modelling and inversion in geophysics.

  9. Technical Note: Response measurement for select radiation detectors in magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, M., E-mail: michaelreynolds@ualberta.net [Department of Oncology, Medical Physics Division, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Fallone, B. G. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Departments of Oncology and Physics, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Rathee, S. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, Medical Physics Division,University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada)

    2015-06-15

    Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

  10. Design of a Command-Triggered Plasma Opening Switch for Terawatt Applications

    International Nuclear Information System (INIS)

    Savage, Mark E.; Mendel, C.W.; Seidel, David B.

    1999-01-01

    Inductive energy storage systems can have high energy density, lending to smaller, less expensive systems. The crucial element of an inductive energy storage system is the opening switch. This switch must conduct current while energy is stored in an inductor, then open quickly to transfer this energy to a load. Plasma can perform this function. The Plasma Opening Switch (POS) has been studied for more than two decades. Success with the conventional plasma opening switch has been limited. A system designed to significantly improve the performance of vacuum opening switches is described in this paper. The gap cleared of plasma is a rough figure-of-merit for vacuum opening switches. Typical opened gaps of 3 mm are reported for conventional switches. The goal for the system described in this paper is more than 3 cm. To achieve this, the command-triggered POS adds an active opening mechanism, which allows complete separation of conduction and opening. This separation is advantageous because of the widely different time scales of conduction and opening. The detrimental process of magnetic field penetration into the plasma during conduction is less important in this switch. The opening mechanism duration is much shorter than the conduction time, so penetration during opening is insignificant. Opening is accomplished with a fast magnetic field that pushes plasma out of the switch region. Plasma must be removed from the switch region to allow high voltage. This paper describes some processes important during conduction and opening, and show calculations on the trigger requirements. The design of the switch is shown. This system is designed to demonstrate both improved performance and nanosecond output jitter at levels greater than one terawatt. An amplification mechanism is described which reduces the trigger energy. Particle-in-cell simulations of the system are also shown

  11. Effect of a gap opening on the conductance of graphene with magnetic barrier structures

    Science.gov (United States)

    Esmailpour, Mohammad

    2018-04-01

    In the present study Klein tunneling in a single-layer gapped graphene was investigated by transfer matrix method under normal magnetic field for one and two magnetic barriers. Calculations show that electron transmission through a magnetic barrier is deflected to positive angles and reduces as the magnitude of magnetic field and especially the energy gap increases. This reduction is even more significant in larger fields so that after reaching a specific value of energy gap, an effective confinement for fermions and suppression of Klein tunneling is reached particularly in normal incidence and the conductance becomes zero. Unlike one barrier, the process of tunneling through two magnetic barriers induces symmetric transmission probability versus the incident angle; even, for lower energy gaps, electron transmission probability increases which in turn reduces total conductance via proper changes in the value of the magnetic field and energy gap. In general, it is concluded that confining electrons in asymmetric transmission through one barrier is conducted better than two barriers.

  12. Enhanced terahertz magnetic dipole response by subwavelength fiber

    Directory of Open Access Journals (Sweden)

    Shaghik Atakaramians

    2018-05-01

    Full Text Available Dielectric sub-wavelength particles have opened up a new platform for realization of magnetic light. Recently, we have demonstrated that a dipole emitter by a sub-wavelength fiber leads to an enhanced magnetic response. Here, we experimentally demonstrate an enhanced magnetic dipole source in the terahertz frequency range. By placing the fiber next to the hole in a metal screen, we find that the radiation power can be enhanced more than one order of magnitude. The enhancement is due to the excitation of the Mie-type resonances in the fiber. We demonstrate that such a system is equivalent to a double-fiber system excited by a magnetic source. This coupled magnetic dipole and optical fiber system can be considered a unit cell of metasurfaces for manipulation of terahertz radiation and is a proof-of-concept of a possibility to achieve enhanced radiation of a dipole source in proximity of a sub-wavelength fiber. It can also be scaled down to optical frequencies opening up promising avenues for developing integrated nanophotonic devices such as nanoantennas or lasers on fibers.

  13. Quasi-open inflation

    CERN Document Server

    García-Bellido, J; Montes, X; Garcia-Bellido, Juan; Garriga, Jaume; Montes, Xavier

    1998-01-01

    We show that a large class of two-field models of single-bubble open inflation do not lead to infinite open universes, as it was previously thought, but to an ensemble of very large but finite inflating `islands'. The reason is that the quantum tunneling responsible for the nucleation of the bubble does not occur simultaneously along both field directions and equal-time hypersurfaces in the open universe are not synchronized with equal-density or fixed-field hypersurfaces. The most probable tunneling trajectory corresponds to a zero value of the inflaton field; large values, necessary for the second period of inflation inside the bubble, only arise as localized fluctuations. The interior of each nucleated bubble will contain an infinite number of such inflating regions of comoving size of order $\\gamma^{-1}$, where $\\gamma$ depends on the parameters of the model. Each one of these islands will be a quasi-open universe. Since the volume of the hyperboloid is infinite, inflating islands with all possible values...

  14. MTN magnet for the SPS extracted beam.

    CERN Document Server

    CERN PhotoLab

    1976-01-01

    This type of dipole magnet was used in the extracted beam lines of the North Area. It shows an opening for three different proton beam lines: a primary extracted proton beam, split by an upstream magnetic beam splitter (see photo 7612017) into three separated beams passes through different parts of its aperture: right, left up, left down. These magnets were designed to be concrete-insulated for radiation resistance. F. Streun stands on the right.

  15. Transcranial magnetic stimulation in developmental stuttering: Relations with previous neurophysiological research and future perspectives.

    Science.gov (United States)

    Busan, P; Battaglini, P P; Sommer, M

    2017-06-01

    Developmental stuttering (DS) is a disruption of the rhythm of speech, and affected people may be unable to execute fluent voluntary speech. There are still questions about the exact causes of DS. Evidence suggests there are differences in the structure and functioning of motor systems used for preparing, executing, and controlling motor acts, especially when they are speech related. Much research has been obtained using neuroimaging methods, ranging from functional magnetic resonance to diffusion tensor imaging and electroencephalography/magnetoencephalography. Studies using transcranial magnetic stimulation (TMS) in DS have been uncommon until recently. This is surprising considering the relationship between the functionality of the motor system and DS, and the wide use of TMS in motor-related disturbances such as Parkinson's Disease, Tourette's Syndrome, and dystonia. Consequently, TMS could shed further light on motor aspects of DS. The present work aims to investigate the use of TMS for understanding DS neural mechanisms by reviewing TMS papers in the DS field. Until now, TMS has contributed to the understanding of the excitatory/inhibitory ratio of DS motor functioning, also helping to better understand and critically review evidence about stuttering mechanisms obtained from different techniques, which allowed the investigation of cortico-basal-thalamo-cortical and white matter/connection dysfunctions. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  16. Operational characteristics of hybrid-type SFCL with closed and open cores

    International Nuclear Information System (INIS)

    Cho, Y.S.; Lee, N.Y.; Choi, H.S.; Chung, D.C.; Lim, S.H.

    2007-01-01

    We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) with the closed and the open cores, which induced the variation of the magnetic flux between the primary and the secondary windings. The experimental set-up of the hybrid-type SFCL with the closed and the open cores were prepared and the experimental analyses for the current limiting characteristics were performed. The peak value of the fault current in the hybrid-type SFCL with the open core was higher than that of the closed core at the first cycle after fault occurrence. However, in the case of the hybrid-type SFCL with the open core, the limiting current level after fault occurrence was decreased less than that of the hybrid-type SFCL with the closed core, because the magnetic leakage reluctance of the open core was higher than that of the closed core. The quench time (T q ) and the arrival time (T a ) for the peak voltage (V SC ) in the hybrid-type SFCL with the closed core were faster than that of the hybrid-type SFCL with the open core due to the increase of the mutual flux. We verified that the consumption power in the hybrid-type SFCL with the open core was larger owing to the increase of leakage flux by the reduction of mutual inductance between primary and secondary windings

  17. A contribution to the study of superconducting magnets

    International Nuclear Information System (INIS)

    Ciazynski, D.

    1983-09-01

    The protection study of a Nb 3 Sn superconducting magnet with high current density brought new information on the calculus of maximum temperature in the coil, the longitudinal and transversal propagation velocity of the normal zone. It has finally led to realization and using as protection device of a superconducting switch allowing to rapidly ''open'' the feeding circuit of the magnet and of a secondary circuit magnetically coupled to the magnet to accelerate the decreasing of the current without increasing the maximum voltage at the magnet connections [fr

  18. Enhanced terahertz magnetic dipole response by subwavelength fiber

    DEFF Research Database (Denmark)

    Atakaramians, Shaghik; Shadrivov, Ilya V.; Miroshnichenko, Andrey E.

    2018-01-01

    Dielectric sub-wavelength particles have opened up a new platform for realization of magnetic light. Recently, we have demonstrated that a dipole emitter by a sub-wavelength fiber leads to an enhanced magnetic response. Here, we experimentally demonstrate an enhanced magnetic dipole source......-fiber system excited by a magnetic source. This coupled magnetic dipole and optical fiber system can be considered a unit cell of metasurfaces for manipulation of terahertz radiation and is a proof-of-concept of a possibility to achieve enhanced radiation of a dipole source in proximity of a sub...

  19. Permanently magnetized high gradient magnetic air filters for the nuclear industry

    International Nuclear Information System (INIS)

    Watson, J.H.P.

    1995-01-01

    This paper describes the structure and testing of two novel permanently magnetized magnetic filters for fine radioactive material. In the first filter the holes in the filter are left open as capture proceeds which means the pressure drop builds up only slowly. This filter is not suitable for composite particles which can be broken by mechanical forces. The second filter has been changed so as to strongly capture particles composed of fine particles weakly bound together which tend to break when captured. This uses a principle of assisted capture in which coarse particles aid the capture of the fine fragments. These filters have the following characteristics: (1) no external magnet is required, (2) no external power is required, (3) small in size and portable, (4) easily interchangeable, and (5) can be cleaned without demagnetizing by using a magnetic fluid which matches the susceptibility of the captured particles

  20. Decreasing the radiation quality factor of magnetic dipole antennas by a magnetic-coated metal core

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.; Breinbjerg, Olav

    2010-01-01

    To achieve the Chu lower bound for the radiation Q, an electrically small magnetic dipole antenna should not store any magnetic energy internally to the minimum sphere enclosing the antenna. As shown in our previous works, the internal stored magnetic energy can be reduced, although not entirely...... eliminated, by introducing a solid magnetic core inside the antenna. In this paper, using analytical results obtained though the vector spherical wave theory, we show that the internal stored magnetic energy can be further reduced, and the Chu lower bound reached, for a spherical magnetic dipole antenna...

  1. Non-empirical Prediction of the Photophysical and Magnetic Properties of Systems with Open d- and f-Shells Based on Combined Ligand Field and Density Functional Theory (LFDFT).

    Science.gov (United States)

    Daul, Claude

    2014-09-01

    Despite the important growth of ab initio and computational techniques, ligand field theory in molecular science or crystal field theory in condensed matter offers the most intuitive way to calculate multiplet energy levels arising from systems with open shells d and/or f electrons. Over the past decade we have developed a ligand field treatment of inorganic molecular modelling taking advantage of the dominant localization of the frontier orbitals within the metal-sphere. This feature, which is observed in any inorganic coordination compound, especially if treated by Density Functional Theory calculation, allows the determination of the electronic structure and properties with a surprising good accuracy. In ligand field theory, the theoretical concepts consider only a single atom center; and treat its interaction with the chemical environment essentially as a perturbation. Therefore success in the simple ligand field theory is no longer questionable, while the more accurate molecular orbital theory does in general over-estimate the metal-ligand covalence, thus yields wave functions that are too delocalized. Although LF theory has always been popular as a semi-empirical method when dealing with molecules of high symmetry e.g. cubic symmetry where the number of parameters needed is reasonably small (3 or 5), this is no more the case for molecules without symmetry and involving both an open d- and f-shell (# parameters ∼90). However, the combination of LF theory and Density Functional (DF) theory that we introduced twenty years ago can easily deal with complex molecules of any symmetry with two and more open shells. The accuracy of these predictions from 1(st) principles achieves quite a high accuracy (<5%) in terms of states energies. Hence, this approach is well suited to predict the magnetic and photo-physical properties arbitrary molecules and materials prior to their synthesis, which is the ultimate goal of each computational chemist. We will illustrate the

  2. Mass ablation and magnetic flux losses through a magnetized plasma-liner wall interface

    Science.gov (United States)

    García-Rubio, F.; Sanz, J.

    2017-07-01

    The understanding of energy and magnetic flux losses in a magnetized plasma medium confined by a cold wall is of great interest in the success of magnetized liner inertial fusion (MagLIF). In a MagLIF scheme, the fuel is magnetized and subsonically compressed by a cylindrical liner. Magnetic flux conservation is degraded by the presence of gradient-driven transport processes such as thermoelectric effects (Nernst) and magnetic field diffusion. In previous publications [Velikovich et al., Phys. Plasmas 22, 042702 (2015)], the evolution of a hot magnetized plasma in contact with a cold solid wall (liner) was studied using the classical collisional Braginskii's plasma transport equations in one dimension. The Nernst term degraded the magnetic flux conservation, while both thermal energy and magnetic flux losses were reduced with the electron Hall parameter ωeτe with a power-law asymptotic scaling (ωeτe)-1/2. In the analysis made in the present paper, we consider a similar situation, but with the liner being treated differently. Instead of a cold solid wall acting as a heat sink, we model the liner as a cold dense plasma with low thermal conduction (that could represent the cryogenic fuel layer added on the inner surface of the liner in a high-gain MagLIF configuration). Mass ablation comes into play, which adds notably differences to the previous analysis. The direction of the plasma motion is inverted, but the Nernst term still convects the magnetic field towards the liner. Magnetization suppresses the Nernst velocity and improves the magnetic flux conservation. Thermal energy in the hot plasma is lost in heating the ablated material. When the electron Hall parameter is large, mass ablation scales as (ωeτe)-3/10, while both the energy and magnetic flux losses are reduced with a power-law asymptotic scaling (ωeτe)-7/10.

  3. Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software.

    Science.gov (United States)

    Rogasch, Nigel C; Sullivan, Caley; Thomson, Richard H; Rose, Nathan S; Bailey, Neil W; Fitzgerald, Paul B; Farzan, Faranak; Hernandez-Pavon, Julio C

    2017-02-15

    The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS-EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS-EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS-EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS-EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS-EEG research. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Open-Phase Fault Tolerance Techniques of Five-Phase Dual-Rotor Permanent Magnet Synchronous Motor

    Directory of Open Access Journals (Sweden)

    Jing Zhao

    2015-11-01

    Full Text Available Multi-phase motors are gaining more attention due to the advantages of good fault tolerance capability and high power density, etc. By applying dual-rotor technology to multi-phase machines, a five-phase dual-rotor permanent magnet synchronous motor (DRPMSM is researched in this paper to further promote their torque density and fault tolerance capability. It has two rotors and two sets of stator windings, and it can adopt a series drive mode or parallel drive mode. The fault-tolerance capability of the five-phase DRPMSM is researched. All open circuit fault types and corresponding fault tolerance techniques in different drive modes are analyzed. A fault-tolerance control strategy of injecting currents containing a certain third harmonic component is proposed for five-phase DRPMSM to ensure performance after faults in the motor or drive circuit. For adjacent double-phase faults in the motor, based on where the additional degrees of freedom are used, two different fault-tolerance current calculation schemes are adopted and the torque results are compared. Decoupling of the inner motor and outer motor is investigated under fault-tolerant conditions in parallel drive mode. The finite element analysis (FMA results and co-simulation results based on Simulink-Simplorer-Maxwell verify the effectiveness of the techniques.

  5. Measurement of flat samples with rough surfaces by Magnetic Adaptive Testing

    Czech Academy of Sciences Publication Activity Database

    Tomáš, Ivan; Kadlecová, Jana; Vértesy, G.

    2012-01-01

    Roč. 48, č. 4 (2012), s. 1441-1444 ISSN 0018-9464. [Conference on Soft Magnetic Materials (SMM20) /20./. Kos Island, 18.09.2011-22.09.2011] R&D Projects: GA ČR GA101/09/1323 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic contact * magnetic adaptive testing * magnetically open samples * magnetic NDE Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.422, year: 2012

  6. Magnetogama: an open schematic magnetometer

    Science.gov (United States)

    Wahyudi; Khakhim, Nurul; Kuntoro, Tri; Mardiatno, Djati; Rakhman, Afif; Setyo Handaru, Anas; Akhmad Mufaqih, Adien; Marwan Irnaka, Theodosius

    2017-09-01

    Magnetogama is an open schematic hand-assembled fluxgate magnetometer. Compared to another magnetometer, Magnetogama has more benefit concerning its price and its ease of use. Practically Magnetogama can be utilized either in land or attached to an unmanned aerial vehicle (UAV). Magnetogama was designed to give open access to a cheap and accurate alternative to magnetometer sensor. Therefore it can be used as a standard design which is directly applicable to the low-budget company or education purposes. Schematic, code and several verification tests were presented in this article ensuring its reproducibility. Magnetogama has been tested with two kind of tests: a comparison with two nearest observatories at Learmonth (LRM) and Kakadu (KDU) and the response of magnetic substance.

  7. Solid state magnetism

    CERN Document Server

    Crangle, John

    1991-01-01

    Solid state magnetism is important and attempts to understand magnetic properties have led to an increasingly deep insight into the fundamental make up of solids. Both experimental and theoretical research into magnetism continue to be very active, yet there is still much ground to cover before there can be a full understanding. There is a strong interplay between the developments of materials science and of magnetism. Hundreds of new materials have been dis­ covered, often with previously unobserved and puzzling magnetic prop­ erties. A large and growing technology exists that is based on the magnetic properties of materials. Very many devices used in everyday life involve magnetism and new applications are being invented all the time. Under­ standing the fundamental background to the applications is vital to using and developing them. The aim of this book is to provide a simple, up-to-date introduction to the study of solid state magnetism, both intrinsic and technical. It is designed to meet the needs a...

  8. The experimental investigation of explosive opening switch

    Energy Technology Data Exchange (ETDEWEB)

    Jiande, Zhang; Huihuang, Zhong; Chuanlu, Li; Yonggui, Liu; Dongqun, Cheng; Xianyang, Peng [National Univ. of Defense Technology, Changsha (China). Dept. of Applied Physics

    1997-12-31

    The explosive opening switch (EOS) used in explosive-driven magnetic-flux compression generator (EMCG) circuits was investigated. It is shown that (1) under certain conditions, the EOS voltage is hardly dependent on the size of the explosive and aluminium foil used in EOS; (2) with the explosive coated by an insulator pipe, the opening effect of EOS is better; (3) by use of EOS, a pulse with 5 kA current, 100 kV voltage and 250 ns risetime has been transferred into a resistance load. (author). 12 figs., 5 refs.

  9. The experimental investigation of explosive opening switch

    International Nuclear Information System (INIS)

    Zhang Jiande; Zhong Huihuang; Li Chuanlu; Liu Yonggui; Cheng Dongqun; Peng Xianyang

    1996-01-01

    The explosive opening switch (EOS) used in explosive-driven magnetic-flux compression generator (EMCG) circuits was investigated. It is shown that (1) under certain conditions, the EOS voltage is hardly dependent on the size of the explosive and aluminium foil used in EOS; (2) with the explosive coated by an insulator pipe, the opening effect of EOS is better; (3) by use of EOS, a pulse with 5 kA current, 100 kV voltage and 250 ns risetime has been transferred into a resistance load. (author). 12 figs., 5 refs

  10. Study of a permanent-magnet dipole with variable field strength and polarity

    International Nuclear Information System (INIS)

    Honma, Toshihiro

    1996-01-01

    A proto-type dipole magnet employing permanent-magnet rods has been designed and constructed. The magnet is able to change the magnetic field strength continuously as well as the polarity of the field direction by rotating the rods. The magnet has a special advantage of high-field production within a small open space available. The magnet of this type will be used for beam steering at an extraction channel for a planned negative-ion acceleration in our cyclotron. The first important objective at the exit channel is to steer the beam extracted from the cyclotron by some dipole magnet onto the optical axis of a new beam line to be constructed. This is not a trivial task because available open space is too small to install a coil-type magnet. One of the selections is to use a permanent-magnet dipole because such a magnet is expected to provide a very high field in a small space when compared with a coil-type magnet. A proto-type permanent-magnet dipole (PMD) with variable field strength and polarity has been designed and constructed for such a purpose. (J.P.N.)

  11. Superconducting Open-Gradient Magnetic Separation for the Pretreatment of Radioactive or Mixed Waste Vitrification Feeds

    International Nuclear Information System (INIS)

    Nunez', L.; Kaminsky', M.D.; Crawford, C.; Ritter, J.A.

    1999-01-01

    An open-gradient magnetic separation (OGMS) process is being considered to separate deleterious elements from radioactive and mixed waste streams prior to vitrification or stabilization. By physically segregating solid wastes and slurries based on the magnetic properties of the solid constituents, this potentially low-cost process may serve the U.S. Department of Energy (DOE) by reducing the large quantities of glass produced from defense-related high-level waste (HLW). Furthermore, the separation of deleterious elements from low-level waste (LLW) also can reduce the total quantity of waste produced in LLW immobilization activities. Many HLW 'and LLW waste' streams at both Hanford and the Savannah River Site (SRS) include constituents deleterious to the durability of borosilicate glass and the melter many of the constituents also possess paramagnetism. For example, Fe, Cr, Ni, and other transition metals may limit the waste loading and affect the durability of the glass by forming spine1 phases at the high operating temperature used in vitrification. Some magnetic spine1 phases observed in glass formation are magnetite (Fe,O,), chromite (FeCrO,), and others [(Fe, Ni, Mg, Zn, Mn)(Al, Fe, Ti, Cr)O,] as described elsewhere [Bates-1994, Wronkiewicz-1994] Stable spine1 phases can cause segregation between the glass and the crystalline phases. As a consequence of the difference in density, the spine1 phases tend to accumulate at the bottom of the glass melter, which decreases the conductivity and melter lifetime [Sproull-1993]. Crystallization also can affect glass durability [Jantzen-1985, Turcotte- 1979, Buechele-1990] by changing the chemical composition of the matrix glass surrounding the crystals or causing stress at the glass/crystal interface. These are some of the effects that can increase leaching [Jantzen-1985]. A SRS glass that was partially crystallized to contain 10% vol. crystals composed of spinels, nepheline, and acmite phases showed minimal changes in

  12. A new method to determine magnetic properties of the unsaturated-magnetized rotor of a novel gyro

    Science.gov (United States)

    Li, Hai; Liu, Xiaowei; Dong, Changchun; Zhang, Haifeng

    2016-06-01

    A new method is proposed to determine magnetic properties of the unsaturated-magnetized, small and irregular shaped rotor of a novel gyro. The method is based on finite-element analysis and the measurements of the magnetic flux density distribution, determining magnetic parameters by comparing the magnetic flux intensity distribution differences between the modeling results under different parameters and the measured ones. Experiment on a N30 Grade NdFeB magnet shows that its residual magnetic flux density is 1.10±0.01 T, and coercive field strength is 801±3 kA/m, which are consistent with the given parameters of the material. The method was applied to determine the magnetic properties of the rotor of the gyro, and the magnetic properties acquired were used to predict the open-loop gyro precession frequency. The predicted precession frequency should be larger than 12.9 Hz, which is close to the experimental result 13.5 Hz. The result proves that the method is accurate in estimating the magnetic properties of the rotor of the gyro.

  13. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  14. On the use of IMAGE FUV for estimating the latitude of the open/closed magnetic field line boundary in the ionosphere

    Directory of Open Access Journals (Sweden)

    P. D. Boakes

    2008-09-01

    Full Text Available A statistical comparison of the latitude of the open/closed magnetic field line boundary (OCB as estimated from the three far ultraviolet (FUV detectors onboard the IMAGE spacecraft (the Wideband Imaging camera, WIC, and the Spectrographic Imagers, SI-12 and SI-13 has been carried out over all magnetic local times. A total of over 400 000 OCB estimations were compared from December 2000 and January and December of 2001–2002. The modal latitude difference between the FUV OCB proxies from the three detectors is small, <1°, except in the predawn and evening sectors, where the SI-12 OCB proxy is found to be displaced from both the SI-13 and WIC OCB proxies by up to 2° poleward in the predawn sector and by up to 2° equatorward in the evening sector. Comparing the IMAGE FUV OCB proxies with that determined from particle precipitation measurements by the Defense Meteorological Satellites Program (DMSP also shows systematic differences. The SI-12 OCB proxy is found to be at higher latitude in the predawn sector, in better agreement with the DMSP OCB proxy. The WIC and SI-13 OCB proxies are found to be in better agreement with the DMSP OCB proxy at most other magnetic local times. These systematic offsets may be used to correct FUV OCB proxies to give a more accurate estimate of the OCB latitude.

  15. Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Robert H. Morris

    2014-11-01

    Full Text Available Magnetic Resonance finds countless applications, from spectroscopy to imaging, routinely in almost all research and medical institutions across the globe. It is also becoming more frequently used for specific applications in which the whole instrument and system is designed for a dedicated application. With beginnings in borehole logging for the petro-chemical industry Magnetic Resonance sensors have been applied to fields as varied as online process monitoring for food manufacture and medical point of care diagnostics. This great diversity is seeing exciting developments in magnetic resonance sensing technology published in application specific journals where they are often not seen by the wider sensor community. It is clear that there is enormous interest in magnetic resonance sensors which represents a significant growth area. The aim of this special edition of Sensors was to address the wide distribution of relevant articles by providing a forum to disseminate cutting edge research in this field in a single open source publication.[...

  16. Superconducting magnets for future particle accelerators

    International Nuclear Information System (INIS)

    Devred, A.

    2000-05-01

    LHC magnet R and D programs shows that the limit for NbTi at 1.9 K could be between 9 and 10 T. Encouraging results have been obtained on a few Nb 3 Sn magnet models, opening the 10 and 15 T range. Given that LHC will have taken nearly 25 years to builds, it is already time to think of the future. (author)

  17. Magnetic Bead—Magic Bullet

    Directory of Open Access Journals (Sweden)

    Christine Ruffert

    2016-01-01

    Full Text Available Microfluidics is assumed to be one of the leading and most promising areas of research since the early 1990s. In microfluidic systems, small spherical magnetic particles with superparamagnetic properties, called magnetic beads, play an important role in the design of innovative methods and tools, especially in bioanalysis and medical sciences. The intention of this review paper is to address main aspects from the state-of-the-art in the area of magnetic bead research, while demonstrating the broad variety of applications and the huge potential to solve fundamental biological and medical problems in the fields of diagnostics and therapy. Basic issues and demands related to the fabrication of magnetic particles and physical properties of nanosize magnets are discussed in Section 2. Of main interest are the control and adjustment of the nanoparticles’ properties and the availability of adequate approaches for particle detection via their magnetic field. Section 3 presents an overview of magnetic bead applications in nanomedicine. In Section 4, practical aspects of sample manipulation and separation employing magnetic beads are described. Finally, the benefits related to the use of magnetic bead-based microfluidic systems are summarized, illustrating ongoing questions and open tasks to be solved on the way to an approaching microfluidic age.

  18. Signal loss in magnetic resonance imaging caused by intraoral anchored dental magnetic materials

    International Nuclear Information System (INIS)

    Blankenstein, F.H.; Naumann, M.; Truong, B.; Thomas, A.; Schroeder, R.J.

    2006-01-01

    Purpose: to measure the maximum extent of the signal loss areas in the center of the susceptibility artifacts generated by ferromagnetic dental magnet attachments using three different sequences in the 1.5 and 3.0 Tesla MRI. Materials and methods: five different pieces of standard dental magnet attachments with volumes of 6.5 to 31.4 mm 3 were used: a NdFeB magnet with an open magnetic field, a NdFeB magnet with a closed magnetic field, a SmCo magnet with an open magnetic field, a stainless steel keeper (AUM-20) and a PdCo piece. The attachments were placed between two cylindrical phantoms and examined in 1.5 and 3.0 Tesla MRI using gradient echo and T1- and T2-weighted spin echoes. We measured the maximum extent of the generated signal loss areas parallel and perpendicular to the direction of B O . Results: in gradient echoes the artifacts were substantially larger and symmetrically adjusted around the object. The areas with total signal loss were mushroom-like with a maximum extent of 7.4 to 9.7 cm parallel to the direction of B O and 6.7 to 7.4 cm perpendicular to B O . In spin echoes the signal loss areas were obviously smaller, but not centered. The maximum values ranged between 4.9 and 7.2 cm (parallel B O ) and 3.6 and 7.0 cm (perpendicular B O ). The different ferromagnetic attachments had no clinically relevant influence on the signal loss neither in 1.5 T nor 3.0 T MRI. Conclusions: ferromagnetic materials used in dentistry are not intraorally standardized. To ensure, that the area of interest is not affected by the described artifacts, the maximum extent of the signal loss area should be assumed: a radius of up to 7 cm in 1.5 and 3.0 T MRI by T1 and T2 sequences, and a radius of up to 10 cm in T2* sequences. To decide whether magnet attachments have to be removed before MR imaging, physicians should consider both the intact retention of the keepers and the safety distance between the ferromagnetic objects and the area of interest. (orig.)

  19. Why develop open-source software? The role of non-pecuniary benefits, monetary rewards, and open-source licence type

    OpenAIRE

    Robert M. Sauer

    2007-01-01

    A review of the basic theory of optimal open-source software contributions points to three key factors affecting the decision to contribute to the open-source development process: nonpecuniary benefits, future expected monetary returns, and open-source licence type. This paper argues that existing large-scale software developer surveys are inadequate for measuring the relative importance of these three factors. Previous econometric studies that collect their own unique datasets also fall shor...

  20. Use of automated test equipment and open-quotes paperlessclose quotes process control to implement efficient production of SSC dipole magnets

    International Nuclear Information System (INIS)

    Tobin, T.; Fagan, R.; Mitchell, D.

    1994-01-01

    In an effort to minimize human error and maximize process control and test capabilities during Collider Dipole Magnets (CDM) production, General Dynamics is developing automated test and process control equipment; known as Test ampersand Process Control Modules (TPCM's). When used along with software designed to create open-quotes paperlessclose quotes process control documentation, the system becomes the Test ampersand Process Control System (TPCS). This system simplifies business decisions and eliminates some problems normally associated with process control documentation, while reducing human errors during CDM production. It is also designed to reduce test operator errors normally incurred during test setup and data analysis. The authors present an overview of the TPCS hardware and software being developed at General Dynamics, along with the process control techniques included in TPCS

  1. The writhe of open and closed curves

    International Nuclear Information System (INIS)

    Berger, Mitchell A; Prior, Chris

    2006-01-01

    Twist and writhe measure basic geometric properties of a ribbon or tube. While these measures have applications in molecular biology, materials science, fluid mechanics and astrophysics, they are under-utilized because they are often considered difficult to compute. In addition, many applications involve curves with endpoints (open curves); but for these curves the definition of writhe can be ambiguous. This paper provides simple expressions for the writhe of closed curves, and provides a new definition of writhe for open curves. The open curve definition is especially appropriate when the curve is anchored at endpoints on a plane or stretches between two parallel planes. This definition can be especially useful for magnetic flux tubes in the solar atmosphere, and for isotropic rods with ends fixed to a plane

  2. Technique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation

    International Nuclear Information System (INIS)

    McDonald, Mark W; Wolanski, Mark R; Simmons, Joseph W; Buchsbaum, Jeffrey C

    2013-01-01

    Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue. Two clinical cases illustrate the use of proton therapy to provide salvage CSI when a previously irradiated OAR required sparing from additional radiation dose. The prior radiation plan was coregistered to the treatment planning CT to create a planning organ at risk volume (PRV) around the OAR. Right and left lateral cranial whole brain proton apertures were created with a small block over the PRV. Then right and left lateral “inverse apertures” were generated, creating an aperture opening in the shape of the area previously blocked and blocking the area previously open. The inverse aperture opening was made one millimeter smaller than the original block to minimize the risk of dose overlap. The inverse apertures were used to irradiate the target volume lateral to the PRV, selecting a proton beam range to abut the 50% isodose line against either lateral edge of the PRV. Together, the 4 cranial proton fields created a region of complete dose avoidance around the OAR. Comparative photon treatment plans were generated with opposed lateral X-ray fields with custom blocks and coplanar intensity modulated radiation therapy optimized to avoid the PRV. Cumulative dose volume histograms were evaluated. Treatment plans were developed and successfully implemented to provide sparing of previously irradiated critical normal structures while treating target brain lateral to these structures. The absence of dose overlapping during irradiation through the inverse apertures was confirmed by film. Compared to the lateral X-ray and IMRT treatment plans, the proton CSI technique improved coverage of target brain tissue while providing the least

  3. Simulation of plasma erosion opening switches

    International Nuclear Information System (INIS)

    Mason, R.J.; Jones, M.E.

    1988-01-01

    Recent progress in the modeling of Plasma Erosion Opening Switches is reviewed, and new results from both fluid and particle simulation compared. Three-fluid simulations with the ANTHEM code for switches on the NRL GAMBLE I machine and SNL PBFA II machine have shown strong dependence of the opening dynamics on the anode structure, the threshold for electron emission, on the possible presence of anomalous resistivity, and on advection of the magnetic field with cathode emitted electrons. Simulations with the implicit particle-in-cell code ISIS confirm these observations, but manifest broader current channels---in better agreement with GAMBLE I experimental results. 7 refs., 3 figs

  4. High energy magnetic excitations

    International Nuclear Information System (INIS)

    Endoh, Yasuo

    1988-01-01

    The report emphasizes that the current development in condensed matter physics opens a research field fit to inelastic neutron scattering experiments in the eV range which is easilly accessed by spallation neutron sources. Several important subjects adopted at thermal reactors are shown. It is desired to extend the implementation of the spectroscopic experiments for investigation of higher energy magnetic excitations. For La 2 CuO 4 , which is the mother crystal of the first high Tc materials found by Bednortz and Muller, it seems to be believed that the magnetism is well characterized by the two-dimensional Heisenberg antiferromagnetic Hamiltonian, and it is widely accepted that the magnetism is a most probable progenitor of high Tc superconductors. The unusual properties of spin correlations in this crystal have been studied extensively by standard neutron scattering techniques with steady neutrons at BNL. FeSi is not ordered magnetically but shows a very unique feature of temperature induced magnetism, which also has been studied extensively by using the thermal neutron scattering technique at BNL. In these experiments, polarized neutrons are indispensable to extract the clean magnetic components out of other components of non-magnetic scattering. (N.K.)

  5. Magnetic and velocity fields in a dynamo operating at extremely small Ekman and magnetic Prandtl numbers

    Science.gov (United States)

    Šimkanin, Ján; Kyselica, Juraj

    2017-12-01

    Numerical simulations of the geodynamo are becoming more realistic because of advances in computer technology. Here, the geodynamo model is investigated numerically at the extremely low Ekman and magnetic Prandtl numbers using the PARODY dynamo code. These parameters are more realistic than those used in previous numerical studies of the geodynamo. Our model is based on the Boussinesq approximation and the temperature gradient between upper and lower boundaries is a source of convection. This study attempts to answer the question how realistic the geodynamo models are. Numerical results show that our dynamo belongs to the strong-field dynamos. The generated magnetic field is dipolar and large-scale while convection is small-scale and sheet-like flows (plumes) are preferred to a columnar convection. Scales of magnetic and velocity fields are separated, which enables hydromagnetic dynamos to maintain the magnetic field at the low magnetic Prandtl numbers. The inner core rotation rate is lower than that in previous geodynamo models. On the other hand, dimensional magnitudes of velocity and magnetic fields and those of the magnetic and viscous dissipation are larger than those expected in the Earth's core due to our parameter range chosen.

  6. Open string in the constant B-field background

    International Nuclear Information System (INIS)

    Jing Jian; Long Zhengwen

    2005-01-01

    A new method is proposed to quantize open strings in this paper. To illustrate our method, we analyze free open string as well as open string in the D-brane background with a nonvanishing B-field, respectively. The Poisson brackets among Fourier components are obtained firstly then we get the Poisson brackets among open string's coordinates. The noncommutativity of coordinates along the D-brane is reproduced. Some ambiguities in the previous discussions can be avoided

  7. Delayed flap coverage of open extremity fractures after previous vacuum-assisted closure (VAC) therapy - worse or worth?

    Science.gov (United States)

    Steiert, Andreas E; Gohritz, Andreas; Schreiber, Thomas C; Krettek, Christian; Vogt, Peter M

    2009-05-01

    Controversy remains regarding timing in the management of complex traumatic lower extremity defects. Many authors recommend a definitive bony and soft tissue reconstruction within a critical period of 72 h, yet in many patients this may be impossible due to concomitant injuries or delayed referral. However, little data are available on the results of delayed flap reconstruction of complex traumatic extremity defects, especially using new technologies of wound coverage such as vacuum-assisted closure (VAC((R))) therapy which may reduce the disadvantages of conventional open wound therapy prior to a subsequent flap reconstruction. We retrospectively analysed the soft tissue reconstructions in 43 open extremity fractures during a 4-year period with special regard to complications, overall flap loss and wound infection. A total of 29 male and 13 female patients with 33 open fractures of the lower and 10 of the upper extremity were included. All patients had been referred from a trauma centre at a mean interval of 19 days (range 1-96 days) after the trauma event with temporary VAC((R)) of their wounds after initial fracture fixation and initial debridement of necrotic tissue. Flap reconstruction was thus only possible later than 72 h and definitive wound closure was achieved at a mean time of 28 days (range 3-106 days). Overall, three pedicled flaps were lost and one of 38 microsurgical free flaps (2.6%) underwent necrosis, the cause of which was unrelated to treatment delay. According to this study, the flap reconstructions performed beyond the frequently quoted critical interval yielded similar results to those of immediate reconstruction within the first 3 days, as reported in the literature. This strategy is in accordance with the principles of 'Damage Control Orthopaedics (DCO)' and may reduce the importance of emergency reconstructions, especially in poly-traumatised patients.

  8. The topology of intrasector reversals of the interplanetary magnetic field

    Science.gov (United States)

    Kahler, S. W.; Crooker, N. U.; Gosling, J. T.

    1996-11-01

    A technique has been developed recently to determine the polarities of interplanetary magnetic fields relative to their origins at the Sun by comparing energetic electron flow directions with local magnetic field directions. Here we use heat flux electrons from the Los Alamos National Laboratory (LANL) plasma detector on the ISEE 3 spacecraft to determine the field polarities. We examine periods within well-defined magnetic sectors when the field directions appear to be reversed from the normal spiral direction of the sector. About half of these intrasector field reversals (IFRs) are cases in which the polarities match those of the surrounding sectors, indicating that those fields have been folded back toward the Sun. The more interesting cases are those with polarity reversals. We find no clear cases of isolated reverse polarity fields, which suggests that islands of reverse polarity in the solar source dipole field probably do not exist. The IFRs with polarity reversals are strongly associated with periods of bidirectional electron flows, suggesting that those fields occur only in conjunction with closed fields. We propose that both those IFRs and the bidirectional flows are signatures of coronal mass ejections (CMEs). In that case, many interplanetary CMEs are larger and more complex than previously thought, consisting of both open and closed field components.

  9. Launched electrons in plasma opening switches

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Rochau, G.E.; Sweeney, M.A.; McDaniel, D.H.; Quintenz, J.P.; Savage, M.E.; Lindman, E.L.; Kindel, J.M.

    1989-01-01

    Plasma opening switches have provided a means to improve the characteristics of super-power pulse generators. Recent advances involving plasma control with fast and slow magnetic fields have made these switches more versatile, allowing for improved switch uniformity, triggering, and opening current levels that are set by the level of auxiliary fields. Such switches necessarily involve breaks in the translational symmetry of the transmission line geometry and therefore affect the electron flow characteristics of the line. These symmetry breaks are the result of high electric field regions caused by plasma conductors remaining in the transmission line, ion beams crossing the line, or auxilliary magnetic field regions. Symmetry breaks cause the canonical momentum of the electrons to change, thereby moving them away from the cathode. Additional electrons are pulled from the cathode into the magnetically insulated flow, resulting in an excess of electron flow over that expected for the voltage and line current downstream of the switch. We call these electrons ''launched electrons''. Unless they are recaptured at the cathode or else are fed into the load and used beneficially, they cause a large power loss downstream. This paper will show examples of SuperMite and PBFA II data showing these losses, explain the tools we are using to study them, and discuss the mechanisms we will employ to mitigate the problem. The losses will be reduced primarily by reducing the amount of launched electron flow. 7 refs., 9 figs

  10. Bench-scale magnetic separation of Department of Energy wastes

    International Nuclear Information System (INIS)

    Hoegler, J.M.

    1987-07-01

    Criteria were developed for selection of candidate wastes for testing magnetic separation of uranium and/or other paramagnetic materials. A survey of Department of Energy (DOE) hazardous wastes was conducted to determine good candidates for bench-scale magnetic separation tests. Representatives of 21 DOE sites were contacted, and 11 materials were identified as potential candidates for magnetic separation. To date, seven samples have been obtained and tested for separability of uranium with a bench-scale magnetic assaying device. The samples tested have been obtained from the K-1401B and K-1401C ponds in Oak Ridge, Tennessee; from waste piles in Maywood, New Jersey; from North and South Ponds in Richland, Washington; and from magnesium fluoride drums in Fernald, Ohio. The magnetic device utilized in these tests can be used in an open-gradient mode with dry particulate or liquid-suspended materials. Uranium separation from magnesium fluoride has shown exceptionally good performance in both open- and high-gradient modes and could be an important application of the technology

  11. The 2016 Bioinformatics Open Source Conference (BOSC).

    Science.gov (United States)

    Harris, Nomi L; Cock, Peter J A; Chapman, Brad; Fields, Christopher J; Hokamp, Karsten; Lapp, Hilmar; Muñoz-Torres, Monica; Wiencko, Heather

    2016-01-01

    Message from the ISCB: The Bioinformatics Open Source Conference (BOSC) is a yearly meeting organized by the Open Bioinformatics Foundation (OBF), a non-profit group dedicated to promoting the practice and philosophy of Open Source software development and Open Science within the biological research community. BOSC has been run since 2000 as a two-day Special Interest Group (SIG) before the annual ISMB conference. The 17th annual BOSC ( http://www.open-bio.org/wiki/BOSC_2016) took place in Orlando, Florida in July 2016. As in previous years, the conference was preceded by a two-day collaborative coding event open to the bioinformatics community. The conference brought together nearly 100 bioinformatics researchers, developers and users of open source software to interact and share ideas about standards, bioinformatics software development, and open and reproducible science.

  12. Gap formation processes in a high-density plasma opening switch

    International Nuclear Information System (INIS)

    Grossmann, J.M.; Swanekamp, S.B.; Ottinger, P.F.; Commisso, R.J.; Hinshelwood, D.D.; Weber, B.V.

    1995-01-01

    A gap opening process in plasma opening switches (POS) is examined with the aid of numerical simulations. In these simulations, a high density (n e =10 14 --5x10 15 cm -3 ) uniform plasma initially bridges a small section of the coaxial transmission line of an inductive energy storage generator. A short section of vacuum transmission line connects the POS to a short circuit load. The results presented here extend previous simulations in the n e =10 12 --10 13 cm -3 density regime. The simulations show that a two-dimensional (2-D) sheath forms in the plasma near a cathode. This sheath is positively charged, and electrostatic sheath potentials that are large compared to the anode--cathode voltage develop. Initially, the 2-D sheath is located at the generator edge of the plasma. As ions are accelerated out of the sheath, it retains its original 2-D structure, but migrates axially toward the load creating a magnetically insulated gap in its wake. When the sheath reaches the load edge of the POS, the POS stops conducting current and the load current increases rapidly. At the end of the conduction phase a gap exists in the POS whose size is determined by the radial dimensions of the 2-D sheath. Simulations at various plasma densities and current levels show that the radial size of the gap scales roughly as B/n e , where B is the magnetic field. The results of this work are discussed in the context of long-conduction-time POS physics, but exhibit the same physical gap formation mechanisms as earlier lower density simulations more relevant to short-conduction-time POS. copyright 1995 American Institute of Physics

  13. Quantum dynamics of crystals of molecular magnets inside microwave resonators

    Energy Technology Data Exchange (ETDEWEB)

    Amigo, R.; Tejada, J.; Chudnovsky, E.M.; Hernandez, J.M.; Garcia-Santiago, A. E-mail: antonio@ubxlab.comtoni@ubxlab.com

    2004-05-01

    It is shown that crystals of molecular nanomagnets exhibit enhanced magnetic relaxation when placed inside a resonant cavity. Strong dependence of the magnetization curve on the geometry of the cavity has been observed, providing evidence of the coherent microwave radiation by the crystals. These observations open the possibility of building a nanomagnetic microwave laser pumped by the magnetic field.

  14. Quantum dynamics of crystals of molecular magnets inside microwave resonators

    International Nuclear Information System (INIS)

    Amigo, R.; Tejada, J.; Chudnovsky, E.M.; Hernandez, J.M.; Garcia-Santiago, A.

    2004-01-01

    It is shown that crystals of molecular nanomagnets exhibit enhanced magnetic relaxation when placed inside a resonant cavity. Strong dependence of the magnetization curve on the geometry of the cavity has been observed, providing evidence of the coherent microwave radiation by the crystals. These observations open the possibility of building a nanomagnetic microwave laser pumped by the magnetic field

  15. Magnetogama: an open schematic magnetometer

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2017-09-01

    Full Text Available Magnetogama is an open schematic hand-assembled fluxgate magnetometer. Compared to another magnetometer, Magnetogama has more benefit concerning its price and its ease of use. Practically Magnetogama can be utilized either in land or attached to an unmanned aerial vehicle (UAV. Magnetogama was designed to give open access to a cheap and accurate alternative to magnetometer sensor. Therefore it can be used as a standard design which is directly applicable to the low-budget company or education purposes. Schematic, code and several verification tests were presented in this article ensuring its reproducibility. Magnetogama has been tested with two kind of tests: a comparison with two nearest observatories at Learmonth (LRM and Kakadu (KDU and the response of magnetic substance.

  16. A 0.5 Tesla Transverse-Field Alternating Magnetic Field Demagnetizer

    Science.gov (United States)

    Schillinger, W. E.; Morris, E. R.; Finn, D. R.; Coe, R. S.

    2015-12-01

    We have built an alternating field demagnetizer that can routinely achieve a maximum field of 0.5 Tesla. It uses an amorphous magnetic core with an air-cooled coil. We have started with a 0.5 T design, which satisfies most of our immediate needs, but we can certainly achieve higher fields. In our design, the magnetic field is transverse to the bore and uniform to 1% over a standard (25 mm) paleomagnetic sample. It is powered by a 1 kW power amplifier and is compatible with our existing sample handler for automated demagnetization and measurement (Morris et al., 2009). It's much higher peak field has enabled us to completely demagnetize many of the samples that previously we could not with commercial equipment. This capability is especially needed for high-coercivity sedimentary and igneous rocks that contain magnetic minerals that alter during thermal demagnetization. It will also enable detailed automated demagnetization of high coercivity phases in extraterrestrial samples, such as native iron, iron-alloy and sulfide minerals that are common in lunar rocks and meteorites. Furthermore, it has opened the door for us to use the rock-magnetic technique of component analysis, using coercivity distributions derived from very detailed AF demagnetization of NRM and remanence produced in the laboratory to characterize the magnetic mineralogy of sedimentary rocks. In addition to the many benefits this instrument has brought to our own research, a much broader potential impact is to replace the transverse coils in automated AF demagnetization systems, which typically are limited to peak fields around 0.1 T.

  17. The EMeRGE modular robot, an open platform for quick testing of evolved robot morphologies

    DEFF Research Database (Denmark)

    Moreno Garcia, Rodrigo; Liu, Ceyue; Faina, Andres

    2017-01-01

    This work presents the hardware design and implementation of the EMeRGE open modular robot platform. EMeRGE (Easy Modular Embodied Robot Generation) modules are designed to be cheap and easy to build and their hardware is open for anyone to use and modify. Four magnetic connectors enable the quick...... assembly of different complex robot morphologies like the ones generated by evolutionary robotics experiments. Non-human agents, like robotic manipulators, can also take advantage of the magnetic connectors to assemble and disassemble morphologies....

  18. X-rays and magnetism

    International Nuclear Information System (INIS)

    Fischer, Peter; Ohldag, Hendrik

    2015-01-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques. (report on progress)

  19. Carbon based magnetism an overview of the magnetism of metal free carbon-based compounds and materials

    CERN Document Server

    Makarova, Tatiana

    2006-01-01

    Magnetism is one of the most intriguing phenomena observed in nature. Magnetism is relevant to physics and geology, biology and chemistry. Traditional magnets, an ubiquitous part of many everyday gadgets, are made of heavy iron- or nickel based materials. Recently there have been reports on the observation of magnetism in carbon, a very light and biocompatible element. Metal-free carbon structures exhibiting magnetic ordering represent a new class of materials and open a novel field of research that could lead to many new technologies. · The most complete, detailed, and accurate Guide in the magnetism of carbon · Dynamically written by the leading experts · Deals with recent scientific highlights · Gathers together chemists and physicists, theoreticians and experimentalists · Unified treatment rather than a series of individually authored papers · Description of genuine organic molecular ferromagnets · Unique description of new carbon materials with Curie temperatures well above ambient.

  20. Larmor labeling by time-gradient magnetic fields

    International Nuclear Information System (INIS)

    Ioffe, Alexander; Bodnarchuk, Victor; Bussmann, Klaus; Mueller, Robert

    2007-01-01

    The Larmor labeling of neutrons, due to the Larmor precession of neutron spin in a magnetic field, opens the unique possibility for the development of neutron spin-echo (NSE) based on neutron scattering techniques, featuring an extremely high energy (momentum) resolution. Here, we present the experimental proof of a new method of the Larmor labeling using time-gradient magnetic fields

  1. Magnetostrictive-piezoelectric magnetic sensor with current excitation

    International Nuclear Information System (INIS)

    Prieto, J.L.; Aroca, C.; Lopez, E.; Sanchez, M.C.; Sanchez, P.

    2000-01-01

    A new working configuration for magnetostrictive-piezoelectric magnetic sensors is presented. In this configuration, the excitation is caused using an electrical current flowing through the ferromagnetic sample and the induced signal is sensed in the piezoelectric support as an electrical voltage. This new idea allows a magnetic field detection without any coil and opens a possibility for a future miniaturisation of the sensor

  2. Power magnetic devices a multi-objective design approach

    CERN Document Server

    Sudhoff, Scott D

    2014-01-01

    Presents a multi-objective design approach to the many power magnetic devices in use today Power Magnetic Devices: A Multi-Objective Design Approach addresses the design of power magnetic devices-including inductors, transformers, electromagnets, and rotating electric machinery-using a structured design approach based on formal single- and multi-objective optimization. The book opens with a discussion of evolutionary-computing-based optimization. Magnetic analysis techniques useful to the design of all the devices considered in the book are then set forth. This material is then used for ind

  3. Resonance of magnetization excited by voltage in magnetoelectric heterostructures

    Science.gov (United States)

    Yu, Guoliang; Zhang, Huaiwu; Li, Yuanxun; Li, Jie; Zhang, Dainan; Sun, Nian

    2018-04-01

    Manipulation of magnetization dynamics is critical for spin-based devices. Voltage driven magnetization resonance is promising for realizing low-power information processing systems. Here, we show through Finite Element Method (FEM) simulations that magnetization resonance in nanoscale magnetic elements can be generated by a radio frequency (rf) voltage via the converse magnetoelectric (ME) effect. The magnetization dynamics induced by voltage in a ME heterostructures is simulated by taking into account the magnetoelastic and piezoelectric coupling mechanisms among magnetization, strain and voltage. The frequency of the excited magnetization resonance is equal to the driving rf voltage frequency. The proposed voltage driven magnetization resonance excitation mechanism opens a way toward energy-efficient spin based device applications.

  4. Proceedings of the workshop on structural analysis needs for magnetic fusion energy superconducting magnets: a technical assessment

    International Nuclear Information System (INIS)

    Reich, M.; Lehner, J.; Powell, J.; Bezler, P.

    1976-01-01

    The technical portions of the meeting were divided into three major sessions as follows: (1) Review of methods being presently used by the MFE community for structural evaluation of current designs. (2) Future structural analysis needs. (3) Open discussions dealing with adequacy of present methods, the improvements needed for MFE magnet structural analysis, and the establishment of an MFE magnet structural advisory group. Summaries of the individual talks are presented

  5. Proceedings of the workshop on structural analysis needs for magnetic fusion energy superconducting magnets: a technical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Reich, M.; Lehner, J.; Powell, J.; Bezler, P.

    1976-01-01

    The technical portions of the meeting were divided into three major sessions as follows: (1) Review of methods being presently used by the MFE community for structural evaluation of current designs. (2) Future structural analysis needs. (3) Open discussions dealing with adequacy of present methods, the improvements needed for MFE magnet structural analysis, and the establishment of an MFE magnet structural advisory group. Summaries of the individual talks are presented.

  6. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields?

    Science.gov (United States)

    Luechinger, Roger; Duru, Firat; Zeijlemaker, Volkert A; Scheidegger, Markus B; Boesiger, Peter; Candinas, Reto

    2002-10-01

    MRI is established as an important diagnostic tool in medicine. However, the presence of a cardiac pacemaker is usually regarded as a contraindication for MRI due to safety reasons. The aim of this study was to investigate the state of a pacemaker reed switch in different orientations and positions in the main magnetic field of 0.5-, 1.5-, and 3.0-T MRI scanners. Reed switches used in current pacemakers and ICDs were tested in 0.5-, 1.5-, and 3.0-T MRI scanners. The closure of isolated reed switches was evaluated for different orientations and positions relative to the main magnetic field. The field strengths to close and open the reed switch and the orientation dependency of the closed state inside the main magnetic field were investigated. The measurements were repeated using two intact pacemakers to evaluate the potential influence of the other magnetic components, like the battery. If the reed switches were oriented parallel to the magnetic fields, they closed at 1.0 +/- 0.2 mT and opened at 0.7 +/- 0.2 mT. Two different reed switch behaviors were observed at different magnetic field strengths. In low magnetic fields ( 200 mT), the reed switches opened in 50% of all tested orientations. No difference between the three scanners could be demonstrated. The reed switches showed the same behavior whether they were isolated or an integral part of the pacemakers. The reed switch in a pacemaker or an ICD does not necessarily remain closed in strong magnetic fields at 0.5, 1.5, or 3.0 T and the state of the reed switch may not be predictable with certainty in clinical situations.

  7. Progress In Research On Open - Ended Magnetic Traps

    International Nuclear Information System (INIS)

    Kruglyakov, E. P.; Burdakov, A. V.; Ivanov, A. A.

    2006-01-01

    At present, three modern types of mirror machines for plasma confinement and heating exist in Novosibirsk (Multi-mirror,-GOL-3, Gas Dynamic Trap,-GDT, and Tandem Mirror,- AMBAL-M). From the engineering point of view all these systems are very attractive because of simple axisymmetric geometry of magnetic configurations. In this paper, the status of GOL-3 and GDT machines is presented. The most crucial experiments for the mirror concept are described such as a demonstration of different principles of suppression of longitudinal electron heat conductivity (GDT, GOL-3), finding of MHD stable regimes of confinement of high β (more than 0.4) plasma in axisymmetric geometry of magnetic field, an effective heating of a dense plasma (of order of 10 21 m-3) by high current relativistic electron beam (GOL-3), etc. In the case of multi-mirror geometry (GOL-3) significant increase of confinement time of hot plasma (up to several tens times) was obtained in comparison with single mirror geometry. Besides, electron heating (up to 2 keV) in result of high current electron beam -- plasma interaction, the heating of ions (up to 2 keV) was discovered in the multi-mirror geometry (55 mirror cells with total length of the trap equal to 12 meters). There was no any effect of ion heating in the single mirror geometry. The reasons of appearance of the ion heating in multi-mirror geometry are discussed. It should be mentioned that on the basis of the GOL-3 and GDT one can obtain an important information for ITER and for future fusion program. In the case of GOL-3 the longitudinal energy density flux of plasma after heating by REB can be so high as 50 MJ/m2. A lot of experiments can be made on plasma-wall interaction (evaporation, erosion and ionization of wall material, propagation of the impurity ions along magnetic field lines at long distances, etc). Some of these experiments are described in this paper. Using principle of confinement of 'warm' collisional plasma placed in gas dynamic

  8. Dipole-sheet multipole magnets for accelerators

    International Nuclear Information System (INIS)

    Walstrom, P.L.

    1993-01-01

    The dipole-sheet formalism can be used to describe both cylindrical current-sheet multipole magnets and cylindrical-bore magnets made up of permanent magnet blocks. For current sheets, the formalism provides a natural way of finding a finite set of turns that approximate a continuous distribution. The formalism is especially useful In accelerator applications where large-bore, short, high-field-quality magnets that are dominated by fringe fields are needed. A further advantage of the approach is that in systems with either open or cylindrically symmetric magnetic boundaries, analytical expressions for the three-dimensional fields that are suitable for rapid numerical evaluation can be derived. This development is described in some detail. Also, recent developments in higher-order particle-beam optics codes based on the formalism are described briefly

  9. CERN Open Days The LHC demystified!

    CERN Multimedia

    2008-01-01

    Lots of surprises are being planned for the CERN Open Days scheduled for 5 and 6 April (see 21 January edition of the Bulletin). Fred’s itinerary on 6 April 20089.00 a.m\tDeparture from SM12 at CERN (the pit down which all the LHC magnets were lowered into the tunnel)9.15 a.m. Saint-Genis theatre10.00 a.m.\tRoussillon communal hall in Crozet 10.50 a.m. La Chenaille communal hall in Echenevex 11.40 a.m. CMS Building SX5 at Cessy 2.30 p.m. La Forge communal hall in Versonnex 3.30 p.m. Le Levant communal hall in Ferney Voltaire4.40 Forum in Meyrin 5.30 p.m. Main Auditorium at CERN For instance, Fred, who fronts the French television programme "C’est pas sorcier" on France 3 will be taking part in the Open Day for the general public on Sunday, 6 April. He will be on board a CERN lorry carrying a 35 tonne 15 m long dipole magnet and will make halts at eight Swiss and French communes around the LHC Ring to meet the local inhabitants (see...

  10. Trephine Transverse Colostomy Is Effective for Patients Who Have Previously Undergone Rectal Surgery

    Science.gov (United States)

    Yeom, Seung-Seop; Jung, Sung Woo; Oh, Se Heon; Lee, Jong Lyul; Yoon, Yong Sik; Park, In Ja; Lim, Seok-Byung; Yu, Chang Sik; Kim, Jin Cheon

    2018-01-01

    Purpose Colostomy creation is an essential procedure for colorectal surgeons, but the preferred method of colostomy varies by surgeon. We compared the outcomes of trephine colostomy creation with open those for the (laparotomy) and laparoscopic methods and evaluated appropriate indications for a trephine colostomy and the advantages of the technique. Methods We retrospectively evaluated 263 patients who had undergone colostomy creation by trephine, open and laparoscopic approaches between April 2006 and March 2016. We compared the clinical features and the operative and postoperative outcomes according to the approach used for stoma creation. Results One hundred sixty-three patients (62%) underwent colostomy surgery for obstructive causes and 100 (38%) for fistulous problems. The mean operative time was significantly shorter with the trephine approach (trephine, 46.0 ± 1.9 minutes; open, 78.7 ± 3.9 minutes; laparoscopic, 63.5 ± 5.0 minutes; P colostomy was feasible for a diversion colostomy (P colostomy is safe and can be implemented quickly in various situations, and compared to other colostomy procedures, the patient’s recovery is faster. Previous laparotomy history was not a contraindication for a trephine colostomy, and a trephine transverse colostomy is feasible for patients who have undergone previous rectal surgery. PMID:29742862

  11. Spectroscopic investigation of species separation in opening switch plasmas

    Science.gov (United States)

    Jackson, S. L.; Phipps, D. G.; Richardson, A. S.; Commisso, R. J.; Hinshelwood, D. D.; Murphy, D. P.; Schumer, J. W.; Weber, B. V.; Boyer, C. N.; Doron, R.; Biswas, S.; Maron, Y.

    2015-11-01

    Interactions between magnetic fields and current-carrying plasmas that lead to the separation of plasma species in multi-species plasmas are being studied in a plasma opening switch geometry. Several Marshall guns are used to inject single or multi-species plasmas between coaxial conductors connected to the output of the Naval Research Laboratory's Hawk pulsed-power generator. Following injection of the plasma, the generator is used at roughly half power to apply an electrical pulse with a peak current of 450 kA, a peak voltage of 400 kV, and a rise time of 1.2 μs. The resulting magnetic field interacts with the plasma through a combination of field penetration and magnetohydrodynamic (MHD) pushing that is not well understood but can lead to the separation of plasma species in multi-species plasmas. An ICCD-coupled spectrometer has been used in combination with magnetic probes, a ribbon-beam interferometer, and particle-in-cell (PIC) modeling to diagnose and understand conditions in the plasma from the time it is injected until the end of the conduction phase of the opening switch. This work supported by the Naval Research Laboratory Base Program and the Office of Naval Research.

  12. Cryogenic magnetic coil and superconducting magnetic shield for neutron electric dipole moment searches

    Science.gov (United States)

    Slutsky, S.; Swank, C. M.; Biswas, A.; Carr, R.; Escribano, J.; Filippone, B. W.; Griffith, W. C.; Mendenhall, M.; Nouri, N.; Osthelder, C.; Pérez Galván, A.; Picker, R.; Plaster, B.

    2017-08-01

    A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search requires a uniform magnetic field to mitigate systematic effects and obtain long polarization lifetimes for neutron spin precession measurements. This paper details upgrades to a previously described apparatus [1], particularly the introduction of super-conducting magnetic shielding and the associated cryogenic apparatus. The magnetic gradients observed are sufficiently low for the nEDM search at SNS.

  13. Slot opening optimization of surface mounted permanent magnet motor for cogging torque reduction

    International Nuclear Information System (INIS)

    Abbaszadeh, K.; Rezaee Alam, F.; Teshnehlab, M.

    2012-01-01

    Highlights: ► The slot opening shift method is an efficient method for cogging torque reduction. ► Using slot opening skew method, the trapezoidal waveform of back-emf is maintained. ► Using the conventional slot skewing, the wave shape of back-emf is sinusoidal. ► The novelty of paper is using of air–gap permeance harmonics as objective function. ► Other novelty of this paper is using the different optimization algorithms. - Abstract: In this paper, slot opening skew method is used for cogging torque reduction. A three layer stator model is considered for a six-pole PM-BLDC motor (a PM-BLDC motor with 18-slots, six-poles and length of 5 cm) and then a 2D dual model is extracted for this 3D slot opening skew model. The angular shifts of slot opening position in the first and third layers than middle layer are considered as optimization parameters. Slot opening shape is optimized by using different optimization algorithms, such as, the response surface methodology (RSM), the genetic algorithm (GA) and the particle swarm optimization (PSO). In order to using of GA and PSO, the analytical relationship is derived for the air–gap permeance function. The optimization results of these algorithms are being consistent with each other and are verified with FEA results. The results show the significant reduction of cogging torque about 77%.

  14. Controlling laser-induced magnetization reversal dynamics in a rare-earth iron garnet across the magnetization compensation point

    Science.gov (United States)

    Deb, Marwan; Molho, Pierre; Barbara, Bernard; Bigot, Jean-Yves

    2018-04-01

    In this work we explore the ultrafast magnetization dynamics induced by femtosecond laser pulses in a doped film of gadolinium iron garnet over a broad temperature range including the magnetization compensation point TM. By exciting the phonon-assisted 6S→4G and 6S→4P electronic d -d transitions simultaneously by one- and two-photon absorption processes, we find out that the transfer of heat energy from the lattice to the spin has, at a temperature slightly below TM, a large influence on the magnetization dynamics. In particular, we show that the speed and the amplitude of the magnetization dynamics can be strongly increased when increasing either the external magnetic field or the laser energy density. The obtained results are explained by a magnetization reversal process across TM. Furthermore, we find that the dynamics has unusual characteristics which can be understood by considering the weak spin-phonon coupling in magnetic garnets. These results open new perspectives for controlling the magnetic state of magnetic dielectrics using an ultrashort optically induced heat pulse.

  15. Nonlinear Electrostatic Wave Equations for Magnetized Plasmas

    DEFF Research Database (Denmark)

    Dysthe, K.B.; Mjølhus, E.; Pécseli, Hans

    1984-01-01

    The lowest order kinetic effects are included in the equations for nonlinear electrostatic electron waves in a magnetized plasma. The modifications of the authors' previous analysis based on a fluid model are discussed.......The lowest order kinetic effects are included in the equations for nonlinear electrostatic electron waves in a magnetized plasma. The modifications of the authors' previous analysis based on a fluid model are discussed....

  16. CERN Open Data Portal - Improving usability and user experience of CMS Open Data research tools.

    CERN Document Server

    Hirvonsalo, Harri

    2015-01-01

    This report summarizes the work I have done during my assignment as participant of CERN Summer Students 2015 programme. Main goal of my Summer Student project was to lower the bar for people to start utilizing open data that CMS experiment has released in November 2014 to CERN Open Data Portal (http://opendata.cern.ch). Project included various working packages and tasks, such as: -Determine the obstacles that potential users of CMS research oriented open data who don’t have previous knowledge about internal workflow of analysis tasks at CMS experiment would run into. -Produce more introductory material and tutorials for conducting basic physics analyses with CMSSW to CERN Open Data Portal. -Study the feasibility of podio-framework (https://github.com/hegner/podio) for CMS Open Data users. The project work was done under the supervision of Kati Lassila-Perini whom I thank greatly for her help, patience and support.

  17. Towards cross-hierarchy simulation of collisionless driven reconnection in an open system

    OpenAIRE

    R., HORIUCHI; H., OHTANI; A., ISHIZAWA

    2006-01-01

    The basic idea of a cross-hierarchy model for magnetic reconnection in an open system is proposed, where a microscopic system is surrounded by a macroscopic system and the interaction between the two systems is expressed by the plasma inflow and outflow through the system boundary. Collisionless driven reconnection in two-dimensional and three-dimensional open systems is demonstrated using an open particle simulation model developed as a microscopic part of a cross-hierarchy model. It is foun...

  18. Changes in the PHOBOS magnet design

    International Nuclear Information System (INIS)

    Shea, J.Y.; Mignerey, A.C.

    1996-01-01

    After more sophisticated simulation and calculation work, it was realized that the design of the PHOBOS magnet could not create a open-quotes field freeclose quotes region for the first four silicon planes for the purpose of tracking. The cut of the pole face was pushed back towards the center of the magnet by 10 cm. The new results from TOSCA were considered acceptable for the purpose of the PHOBOS tracking equipment

  19. Magnetic Topology and Ion Outflow in Mars' Magnetotail

    Science.gov (United States)

    Mitchell, D. L.; Xu, S.; McFadden, J. P.; Hara, T.; Luhmann, J. G.; Mazelle, C. X.; Andersson, L.; DiBraccio, G. A.; Connerney, J. E. P.

    2017-12-01

    Planetary ion outflow down the Martian magnetotail could be an important atmospheric loss mechanism. This process depends on magnetic connectivity to the day-side ionosphere and on acceleration of ions to escape velocity. The Mars Atmosphere and Volatile Evolution (MAVEN) mission has obtained comprehensive ion, electron, and magnetic field data in Mars' magnetotail. The spacecraft is in a 75°-inclination, elliptical orbit that samples altitudes from 150 to 6200 km. As the orbit precesses, it sweeps through the tail at a variety of altitudes in this range. Data from the Solar Wind Electron Analyzer (SWEA) and Magnetometer (MAG) are used to determine the magnetic field topology in the tail at high cadence (every 2-4 seconds), and in particular whether field lines are open, closed, or draped, and if open whether they have access to the day-side or night-side ionosphere. Simultaneous observations by the Supra-Thermal and Thermal Ion Composition (STATIC) instrument and the Langmuir Probe and Waves (LPW) experiment are used to measure the density, composition, and velocity of planetary plasma on these field lines. We find that magnetic topology in the tail is complex and variable, and is influenced by the IMF polarity and the orientation of Mars' crustal magnetic fields with respect to the Sun. We find that planetary ion outflow occurs on both open and draped field lines. On open field lines, outflow tends to occur parallel to the field line, with colder, denser, and slower outflow on field lines connected to the day-side ionosphere (Fig. 1). On these same field lines (after correction for the spacecraft potential) a shift in the position of the He-II photoelectron feature indicates a 1-Volt parallel electric potential directed away from the planet. Except for H+ and occasionally O+, this potential is insufficient by itself to accelerate planetary ions to escape velocity. Outflow is warmer, less dense, and faster moving on draped field lines. In this case, the ion bulk

  20. Current induced multi-mode propagating spin waves in a spin transfer torque nano-contact with strong perpendicular magnetic anisotropy

    Science.gov (United States)

    Mohseni, S. Morteza; Yazdi, H. F.; Hamdi, M.; Brächer, T.; Mohseni, S. Majid

    2018-03-01

    Current induced spin wave excitations in spin transfer torque nano-contacts are known as a promising way to generate exchange-dominated spin waves at the nano-scale. It has been shown that when these systems are magnetized in the film plane, broken spatial symmetry of the field around the nano-contact induced by the Oersted field opens the possibility for spin wave mode co-existence including a non-linear self-localized spin-wave bullet and a propagating mode. By means of micromagnetic simulations, here we show that in systems with strong perpendicular magnetic anisotropy (PMA) in the free layer, two propagating spin wave modes with different frequency and spatial distribution can be excited simultaneously. Our results indicate that in-plane magnetized spin transfer nano-contacts in PMA materials do not host a solitonic self-localized spin-wave bullet, which is different from previous studies for systems with in plane magnetic anisotropy. This feature renders them interesting for nano-scale magnonic waveguides and crystals since magnon transport can be configured by tuning the applied current.

  1. TMX magnet system, present and future

    International Nuclear Information System (INIS)

    Wong, R.L.; Pedrotti, L.R.; Leavitt, G.A.; Waugh, A.F.; Chargin, A.K.; Calderon, M.O.

    1979-01-01

    The magnetic field design and the mechanical design of the TMX magnet system were previously reported by Chen and Hinkle. This paper is a summary of the work that has been accomplished in the two years since then

  2. Cascade of Quantum Transitions and Magnetocaloric Anomalies in an Open Nanowire

    Science.gov (United States)

    Val'kov, V. V.; Mitskan, V. A.; Shustin, M. S.

    2017-12-01

    A sequence of magnetocaloric anomalies occurring with the change in a magnetic field H is predicted for an open nanowire with the Rashba spin-orbit coupling and the induced superconducting pairing potential. The nature of such anomalies is due to the cascade of quantum transitions related to the successive changes in the fermion parity of the nanowire ground state with the growth of the magnetic field. It is shown that the critical H c values fall within the parameter range corresponding to the nontrivial values of the Z 2 topological invariant of the corresponding 1D band Hamiltonian characteristic of the D symmetry class. It is demonstrated that such features in the behavior of the open nanowire are retained even in the presence of Coulomb interactions.

  3. Dynamics of the Energy Transfer to the Load During the Operation of a Plasma Opening Switch

    International Nuclear Information System (INIS)

    Dolinsky, Yu.; Krasik, Ya.E.; Felsteiner, J.

    1999-01-01

    The main efforts of the theoretical and experimental studies related to the Plasma Opening Switch (POS) have been devoted to the understanding of an anomalous fast magnetic field penetration through the plasma. At present this phenomenon can be explained based on the electron magnetohydrodynamic theory.l The second important phenomenon is related with POS opening. Existing models explain POS opening as a result of cut-off of the electron current component in the double layer2 by self-magnetic field of the POS current or by the increase of the Hall potential in the current layer due to ion erosion.3 Nevertheless both models consider POS opening in the region which was preliminary occupied by the plasma. In a recent experiment4 it was shown that the POS opening is related with a fast charged particle flow in the downstream region, namely at the load. In this work we present results of theoretical studies of the phase of the POS operation when the self-magnetic field of the POS current appears at the downstream side of the plasma. Our study has been done within the framework of two-fluid magnetohydrodynamic theory. Taking into account the Hall electric field which is responsible for a strong ion acceleration in the axial direction, we found the velocity of the ions. In addition we show, that due to the inductive electric field caused by the motion of the axial current carrying plasma, the velocity of the magnetic field penetration is equal to the Alfven velocity

  4. 2nd Latin American Workshop on Magnetism, Magnetic Materials, and Their Applications

    CERN Document Server

    Sanchez, J

    1994-01-01

    During August 24-27, 1993, approximately 60 scientists from the Americas, Europe and Japan, gathered in the city of Guanajuato, in the state of Guanajuato, Mexico, at the II Latin American Workshop on Magnetism, Magnetic Materials and their Applications. The group of scientists converging into the beautiful city of Guanajuato had come from Argentina, Chile, Brazil, Venezuela, Cuba, several places in Mexico, U. S. A. , Japan, Spain, France, Italy, Germany, Austria, Switzerland, and Denmark. The event attested to the success of the previous Workshop on Magnetism, Magnetic Materials and their Applications, held in Havana, Cuba, in 1991, as well as to the interest, level of activity and quality of the work being carried out in Latin America in the area of magnetism and magnetic materials. Equally important to everyone present was the fact that we had come to honor a friend, Professor L. M. Falicov, on his sixtieth birthday. The choice of a Latin American Workshop on magnetism as a Festschrift for Leo Falicov was,...

  5. Parallel Simulation of HGMS of Weakly Magnetic Nanoparticles in Irrotational Flow of Inviscid Fluid

    Directory of Open Access Journals (Sweden)

    Kanok Hournkumnuard

    2014-01-01

    Full Text Available The process of high gradient magnetic separation (HGMS using a microferromagnetic wire for capturing weakly magnetic nanoparticles in the irrotational flow of inviscid fluid is simulated by using parallel algorithm developed based on openMP. The two-dimensional problem of particle transport under the influences of magnetic force and fluid flow is considered in an annular domain surrounding the wire with inner radius equal to that of the wire and outer radius equal to various multiples of wire radius. The differential equations governing particle transport are solved numerically as an initial and boundary values problem by using the finite-difference method. Concentration distribution of the particles around the wire is investigated and compared with some previously reported results and shows the good agreement between them. The results show the feasibility of accumulating weakly magnetic nanoparticles in specific regions on the wire surface which is useful for applications in biomedical and environmental works. The speedup of parallel simulation ranges from 1.8 to 21 depending on the number of threads and the domain problem size as well as the number of iterations. With the nature of computing in the application and current multicore technology, it is observed that 4–8 threads are sufficient to obtain the optimized speedup.

  6. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  7. TIME-RESOLVED SPECTROSCOPY OF THE POLAR EU CANCRI IN THE OPEN CLUSTER MESSIER 67

    International Nuclear Information System (INIS)

    Williams, Kurtis A.; Howell, Steve B.; Liebert, James; Smith, Paul S.; Bellini, Andrea; Rubin, Kate H. R.; Bolte, Michael

    2013-01-01

    We present time-resolved spectroscopic and polarimetric observations of the AM Her system EU Cnc. EU Cnc is located near the core of the old open cluster Messier 67; new proper motion measurements indicate that EU Cnc is indeed a member of the star cluster, and this system therefore is useful to constrain the formation and evolution of magnetic cataclysmic variables. The spectra exhibit two-component emission features with independent radial velocity variations as well as time-variable cyclotron emission indicating a magnetic field strength of 41 MG. The period of the radial velocity and cyclotron hump variations are consistent with the previously known photometric period, and the spectroscopic flux variations are consistent in amplitude with previous photometric amplitude measurements. The secondary star is also detected in the spectrum. We also present polarimetric imaging measurements of EU Cnc that show a clear detection of polarization, and the degree of polarization drops below our detection threshold at phases when the cyclotron emission features are fading or not evident. The combined data are all consistent with the interpretation that EU Cnc is a low-state polar in the cluster Messier 67. The mass function of the system gives an estimate of the accretor mass of M WD ≥ 0.68 M ☉ with M WD ≈ 0.83 M ☉ for an average inclination. We are thus able to place a lower limit on the progenitor mass of the accreting white dwarf of ≥1.43 M ☉ .

  8. Summary of the workshop on structural analysis needs for magnetic fusion energy superconducting magnets

    International Nuclear Information System (INIS)

    Reich, M.; Lehner, J.; Powell, J.

    1976-09-01

    The technical portions of the meeting were divided into three major sessions as follows: (1) Review of methods being presently used by the MFE community for structural evaluation of current designs. (2) Future structural analysis needs. (3) Open discussions dealing with adequacy of present methods, the improvements needed for MFE magnet structural analysis, and the establishment of an MFE magnet structural advisory group. Summaries of the individual talks presented on Wednesday and Thursday (i.e., items 1 and 2 above) are included following the workshop schedule given later in this synopsis

  9. A spiral, bi-planar gradient coil design for open magnetic resonance imaging.

    Science.gov (United States)

    Zhang, Peng; Shi, Yikai; Wang, Wendong; Wang, Yaohui

    2018-01-01

    To design planar gradient coil for MRI applications without discretization of continuous current density and loop-loop connection errors. In the new design method, the coil current is represented using a spiral curve function described by just a few control parameters. Using a proper parametric equation set, an ensemble of spiral contours is reshaped to satisfy the coil design requirements, such as gradient linearity, inductance and shielding. In the given case study, by using the spiral coil design, the magnetic field errors in the imaging area were reduced from 5.19% (non-spiral design) to 4.47% (spiral design) for the transverse gradient coils, and for the longitudinal gradient coil design, the magnetic field errors were reduced to 5.02% (spiral design). The numerical evaluation shows that when compared with conventional wire loop, the inductance and resistance of spiral coil was reduced by 11.55% and 8.12% for x gradient coil, respectively. A novel spiral gradient coil design for biplanar MRI systems, the new design offers better magnetic field gradients, smooth contours than the conventional connected counterpart, which improves manufacturability.

  10. Rotating magnetic field induced oscillation of magnetic particles for in vivo mechanical destruction of malignant glioma.

    Science.gov (United States)

    Cheng, Yu; Muroski, Megan E; Petit, Dorothée C M C; Mansell, Rhodri; Vemulkar, Tarun; Morshed, Ramin A; Han, Yu; Balyasnikova, Irina V; Horbinski, Craig M; Huang, Xinlei; Zhang, Lingjiao; Cowburn, Russell P; Lesniak, Maciej S

    2016-02-10

    Magnetic particles that can be precisely controlled under a magnetic field and transduce energy from the applied field open the way for innovative cancer treatment. Although these particles represent an area of active development for drug delivery and magnetic hyperthermia, the in vivo anti-tumor effect under a low-frequency magnetic field using magnetic particles has not yet been demonstrated. To-date, induced cancer cell death via the oscillation of nanoparticles under a low-frequency magnetic field has only been observed in vitro. In this report, we demonstrate the successful use of spin-vortex, disk-shaped permalloy magnetic particles in a low-frequency, rotating magnetic field for the in vitro and in vivo destruction of glioma cells. The internalized nanomagnets align themselves to the plane of the rotating magnetic field, creating a strong mechanical force which damages the cancer cell structure inducing programmed cell death. In vivo, the magnetic field treatment successfully reduces brain tumor size and increases the survival rate of mice bearing intracranial glioma xenografts, without adverse side effects. This study demonstrates a novel approach of controlling magnetic particles for treating malignant glioma that should be applicable to treat a wide range of cancers. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Magnetic Monopoles and Topology of Yang-Mills Theory in Polyakov Gauge

    OpenAIRE

    Quandt, M.; Reinhardt, H.; Schafke, A.

    1998-01-01

    We express the Pontryagin index in Polyakov gauge completely in terms of magnetically charged gauge fixing defects, namely magnetic monopoles, lines, and domain walls. Open lines and domain walls are topologically equivalent to monopoles, which are the genuine defects. The emergence of non-genuine magnetically charged closed domain walls can be avoided by choosing the temporal gauge field smoothly. The Pontryagin index is then exclusively determined by the magnetic monopoles.

  12. MAGNETIC ENERGY BUILDUP FOR RELATIVISTIC MAGNETAR GIANT FLARES

    International Nuclear Information System (INIS)

    Yu Cong

    2011-01-01

    Motivated by coronal mass ejection studies, we construct general relativistic models of a magnetar magnetosphere endowed with strong magnetic fields. The equilibrium states of the stationary, axisymmetric magnetic fields in the magnetar magnetosphere are obtained as solutions of the Grad-Shafranov equation in a Schwarzschild spacetime. To understand the magnetic energy buildup in the magnetar magnetosphere, a generalized magnetic virial theorem in the Schwarzschild metric is newly derived. We carefully address the question whether the magnetar magnetospheric magnetic field can build up sufficient magnetic energy to account for the work required to open up the magnetic field during magnetar giant flares. We point out the importance of the Aly-Sturrock constraint, which has been widely studied in solar corona mass ejections, as a reference state in understanding magnetar energy storage processes. We examine how the magnetic field can possess enough energy to overcome the Aly-Sturrock energy constraint and open up. In particular, general relativistic (GR) effects on the Aly-Sturrock energy constraint in the Schwarzschild spacetime are carefully investigated. It is found that, for magnetar outbursts, the Aly-Sturrock constraint is more stringent, i.e., the Aly-Sturrock energy threshold is enhanced due to the GR effects. In addition, neutron stars with greater mass have a higher Aly-Sturrock energy threshold and are more difficult to erupt. This indicates that magnetars are probably not neutron stars with extreme mass. For a typical neutron star with mass of 1-2 M sun , we further explore the cross-field current effects, caused by the mass loading, on the possibility of stored magnetic field energy exceeding the Aly-Sturrock threshold.

  13. New MAGLEV link opens door to world sales

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-13

    When the magnetic levitation people mover-or advanced transit shuttle-linking Birmingham airport with the international railway station opens in 1984, it is expected to be the first revenue-earning system of its kind in the world. The project and the high hopes of its backers for future sales are discussed.

  14. Physics of magnetic flux tubes

    CERN Document Server

    Ryutova, Margarita

    2015-01-01

    This book is the first account of the physics of magnetic flux tubes from their fundamental properties to collective phenomena in an ensembles of flux tubes. The physics of magnetic flux tubes is absolutely vital for understanding fundamental physical processes in the solar atmosphere shaped and governed by magnetic fields. High-resolution and high cadence observations from recent space and  ground-based instruments taken simultaneously at different heights and temperatures not only show the ubiquity of filamentary structure formation but also allow to study how various events are interconnected by system of magnetic flux tubes. The book covers both theory and observations. Theoretical models presented in analytical and phenomenological forms are tailored for practical applications. These are welded with state-of-the-art observations from early decisive ones to the most recent data that open a new phase-space for exploring the Sun and sun-like stars. Concept of magnetic flux tubes is central to various magn...

  15. A Hall-current model of electron loss after POS opening into high-impedance loads

    International Nuclear Information System (INIS)

    Greenly, J.B.

    1989-01-01

    The author discusses how a self-consistent relativistic model of laminar Hall (E x B) electron flow across a POS plasma allows a loss mechanism after opening even in a strongly magnetically-insulated line, downstream of the remaining POS plasma. Opening is assumed to occur at the cathode, either by erosion or push-back. The loss results only when a large voltage appears after opening into a high impedance load. Then the difference in potential between the plasma, which is near anode potential, and the cathode results in an axial component of E at the load end of the plasma, which supports an E x B drift of electrons across the gap. The analytic model predicts that this loss should increase with higher voltage after opening, and could be eliminated only by removing the plasma from the gap, or eliminating cathode electron emission (both difficult), or by confining this downstream electron flow with an applied magnetic field

  16. Magnetic field sensor based on cascaded microfiber coupler with magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Lianmin; Su, Delong; Wang, Zhaofang [College of Science, University of Shanghai for Science and Technology, Shanghai 200093 (China); Pu, Shengli, E-mail: shlpu@usst.edu.cn [College of Science, University of Shanghai for Science and Technology, Shanghai 200093 (China); Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, Shanghai 200093 (China); Zeng, Xianglong [The Key Lab of Specialty Fiber Optics and Optical Access Network, Shanghai University, Shanghai 200072 (China); Lahoubi, Mahieddine [Laboratory L.P.S., Department of Physics, Faculty of Sciences, Badji-Mokhtar Annaba University, Annaba 23000 (Algeria)

    2016-09-07

    A kind of magnetic field sensor based on cascaded microfiber coupler with magnetic fluid is proposed and experimentally demonstrated. The magnetic fluid is utilized as the cladding of the fused regions of the cascaded microfiber coupler. As the interference valley wavelength of the sensing structure is sensitive to the ambient variation, considering the magnetic-field-dependent refractive index of magnetic fluid, the proposed structure is employed for magnetic field sensing. The effective coupling length for each coupling region of the as-fabricated cascaded microfiber coupler is 6031 μm. The achieved sensitivity is 125 pm/Oe, which is about three times larger than that of the previously similar structure based on the single microfiber coupler. Experimental results indicate that the sensing sensitivity can be easily improved by increasing the effective coupling length or cascading more microfiber couplers. The proposed magnetic field sensor is attractive due to its low cost, immunity to electromagnetic interference, as well as high sensitivity, which also has the potentials in other tunable all-fiber photonic devices, such as filter.

  17. Rolled-up magnetic sensor: nanomembrane architecture for in-flow detection of magnetic objects.

    Science.gov (United States)

    Mönch, Ingolf; Makarov, Denys; Koseva, Radinka; Baraban, Larysa; Karnaushenko, Daniil; Kaiser, Claudia; Arndt, Karl-Friedrich; Schmidt, Oliver G

    2011-09-27

    Detection and analysis of magnetic nanoobjects is a crucial task in modern diagnostic and therapeutic techniques applied to medicine and biology. Accomplishment of this task calls for the development and implementation of electronic elements directly in fluidic channels, which still remains an open and nontrivial issue. Here, we present a novel concept based on rolled-up nanotechnology for fabrication of multifunctional devices, which can be straightforwardly integrated into existing fluidic architectures. We apply strain engineering to roll-up a functional nanomembrane consisting of a magnetic sensor element based on [Py/Cu](30) multilayers, revealing giant magnetoresistance (GMR). The comparison of the sensor's characteristics before and after the roll-up process is found to be similar, allowing for a reliable and predictable method to fabricate high-quality ultracompact GMR devices. The performance of the rolled-up magnetic sensor was optimized to achieve high sensitivity to weak magnetic fields. We demonstrate that the rolled-up tube itself can be efficiently used as a fluidic channel, while the integrated magnetic sensor provides an important functionality to detect and respond to a magnetic field. The performance of the rolled-up magnetic sensor for the in-flow detection of ferromagnetic CrO(2) nanoparticles embedded in a biocompatible polymeric hydrogel shell is highlighted. © 2011 American Chemical Society

  18. Imaging by magnetic resonance

    International Nuclear Information System (INIS)

    Duroure, J.F.; Serpolay, H.; Vallens, D.

    1995-01-01

    Here are described the advanced technology for nuclear magnetic resonance imaging: reduction of acquisition times, and rebuilding times, images quality improvement. The tendency is to open the machines at low and middle field, on a market being at 10% of NMR I sales, with economical, scientifical and ergonomic reasons broadly developed by constructors

  19. Magnetically self-insulated transformers

    International Nuclear Information System (INIS)

    Novac, B.M.; Smith, I.R.; Brown, J.

    2002-01-01

    Magnetic insulation is the only practicable form of insulation for much equipment used in ultrahigh pulsed-power work, including transmission lines and plasma opening switches. It has not however so far been successfully exploited in the transformers that are necessarily involved, and the first proposed design that appeared more than 30 years ago raised apparently insuperable problems. The two novel arrangements for a magnetically insulated transformer described in this paper overcome the problems faced by the earlier designs and also offer considerable scope for development in a number of important areas. Theoretical justification is given for their insulating properties, and this is confirmed by proof-of-principle results obtained from a small-scale experimental prototype in which magnetic insulation was demonstrated at up to 100 kV. (author)

  20. Magnetic Helicities and Dynamo Action in Magneto-rotational Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Bodo, G.; Rossi, P. [INAF/Osservatorio Astrofisico di Torino, Strada Osservatorio 20, I-10025 Pino Torinese (Italy); Cattaneo, F. [Department of Astronomy and Astrophysics, The University of Chicago, 5640 S. Ellis Avenue, Chicago IL 60637 (United States); Mignone, A., E-mail: bodo@oato.inaf.it [Dipartimento di Fisica, Università degli Studi di Torino, Via Pietro Giuria 1, 10125 Torino (Italy)

    2017-07-10

    We examine the relationship between magnetic flux generation, taken as an indicator of large-scale dynamo action, and magnetic helicity, computed as an integral over the dynamo volume, in a simple dynamo. We consider dynamo action driven by magneto-rotational turbulence (MRT) within the shearing-box approximation. We consider magnetically open boundary conditions that allow a flux of helicity in or out of the computational domain. We circumvent the problem of the lack of gauge invariance in open domains by choosing a particular gauge—the winding gauge—that provides a natural interpretation in terms of the average winding number of pairwise field lines. We use this gauge precisely to define and measure the helicity and the helicity flux for several realizations of dynamo action. We find in these cases that the system as a whole does not break reflectional symmetry and that the total helicity remains small even in cases when substantial magnetic flux is generated. We find no particular connection between the generation of magnetic flux and the helicity or the helicity flux through the boundaries. We suggest that this result may be due to the essentially nonlinear nature of the dynamo processes in MRT.

  1. Micro-fabricated integrated coil and magnetic circuit and method of manufacturing thereof

    Science.gov (United States)

    Mihailovich, Robert E.; Papavasiliou, Alex P.; Mehrotra, Vivek; Stupar, Philip A.; Borwick, III, Robert L.; Ganguli, Rahul; DeNatale, Jeffrey F.

    2017-03-28

    A micro-fabricated electromagnetic device is provided for on-circuit integration. The electromagnetic device includes a core. The core has a plurality of electrically insulating layers positioned alternatingly between a plurality of magnetic layers to collectively form a continuous laminate having alternating magnetic and electrically insulating layers. The electromagnetic device includes a coil embedded in openings of the semiconductor substrate. An insulating material is positioned in the cavity and between the coil and an inner surface of the core. A method of manufacturing the electromagnetic device includes providing a semiconductor substrate having openings formed therein. Windings of a coil are electroplated and embedded in the openings. The insulating material is coated on or around an exposed surface of the coil. Alternating magnetic layers and electrically insulating layers may be micro-fabricated and electroplated as a single and substantially continuous segment on or around the insulating material.

  2. Empowering Learners with Mobile Open-Access Learning Initiatives

    Science.gov (United States)

    Mills, Michael, Ed.; Wake, Donna, Ed.

    2017-01-01

    Education has been progressing at a rapid pace ever since educators have been able to harness the power of mobile technology. Open-access learning techniques provide more students with the opportunity to engage in educational opportunities that may have been previously restricted. "Empowering Learners with Mobile Open-Access Learning…

  3. MAGNETS FOR A MUON STORAGE RING

    International Nuclear Information System (INIS)

    PARKER, B.; ANERELLA, M.; GHOSH, A.; GUPTA, R.; HARRISON, M.; SCHMALZLE, J.; SONDERICKER, J.; WILLEN, E.

    2002-01-01

    We present a new racetrack coil magnet design, with an open midplane gap, that keeps decay particles in a neutrino factory muon storage ring from directly hitting superconducting coils. The structure is very compact because coil ends overlap middle sections top and bottom for skew focusing optics. A large racetrack coil bend radius allows ''react and wind'' magnet technology to be used for brittle Nb 3 Sn superconductors. We describe two versions: Design-A, a magnet presently under construction and Design-B, a further iterated concept that achieves the higher magnetic field quality specified in the neutrino factory feasibility Study-II report. For Design-B reverse polarity and identical end design of consecutive long and short coils offers theoretically perfect magnet end field error cancellation. These designs avoid the dead space penalty from coil ends and interconnect regions (a large fraction in machines with short length but large aperture magnets) and provide continuous bending or focusing without interruption. The coil support structure and cryostat are carefully optimized

  4. Open-closed homotopy algebra in mathematical physics

    International Nuclear Information System (INIS)

    Kajiura, Hiroshige; Stasheff, Jim

    2006-01-01

    In this paper we discuss various aspects of open-closed homotopy algebras (OCHAs) presented in our previous paper, inspired by Zwiebach's open-closed string field theory, but that first paper concentrated on the mathematical aspects. Here we show how an OCHA is obtained by extracting the tree part of Zwiebach's quantum open-closed string field theory. We clarify the explicit relation of an OCHA with Kontsevich's deformation quantization and with the B-models of homological mirror symmetry. An explicit form of the minimal model for an OCHA is given as well as its relation to the perturbative expansion of open-closed string field theory. We show that our open-closed homotopy algebra gives us a general scheme for deformation of open string structures (A ∞ algebras) by closed strings (L ∞ algebras)

  5. Probing into the effects of a magnetic field on the electrode processes of iron in sulphuric acid solutions with dichromate based on the fundamental electrochemistry kinetics

    International Nuclear Information System (INIS)

    Lu Zhanpeng; Huang Delun; Yang Wu

    2005-01-01

    The effects of an applied magnetic field on the electrode processes of iron in sulphuric acid solutions with dichromate have been investigated by electrochemical measurements. Open circuit potentials, cathodic and anodic polarisation curves, values of polarisation resistance were measured in the presence or absence of a 0.4 T horizontal magnetic field (HMF). A potentiostatic polarisation plus magnetic field perturbation technique was used to study the effect of the magnetic field on open circuit corrosion. Cathodic reaction rates at open circuit potentials for iron in sulphuric acid solutions containing dichromate ions are controlled by both the electron-transfer process and the diffusion process. A magnetic field made the open circuit potential move in the positive direction, and changes of the open circuit potentials due to the magnetic field increase with increasing dichromate concentration. When iron was potentiostatically polarised at open circuit potentials in the absence of a magnetic field, a cathodic current was observed after a magnetic field was imposed. Such cathodic currents induced by the magnetic field increases with increasing dichromate concentration. The positive shifts of open circuit potential, the decrease of polarisation resistance, and the occurrence of cathodic currents induced by the magnetic field are caused by the accelerating effect of magnetic field on the cathodic diffusion process. Measured current densities showed lower, equal, or higher values in the presence of the magnetic field than those in the absence of a magnetic field at certain anodic potentials. This effect of the magnetic field is related to the contribution of the cathodic and anodic reactions to the measured current and the types of rate-determining steps for each reaction at certain potentials. The applied magnetic field significantly decreased the polarisation resistance. The experimental results in this paper are formulated based on the fundamental electrochemistry

  6. Simulation of Quantum Tunnelling in an Open System

    Science.gov (United States)

    Fernández, Julio F.

    2003-04-01

    Magnetic clusters, such as Fe8 and Mn12, within large organic molecules, behave at low temperature T as large single spins S, that is, as single molecule magnets (SMM's). In crystals, magnetic anisotropy gives rise to energy barriers U, and quantum tunnelling is then the only available path for magnetic relaxation at vanishingly small temperatures. Even this path, however, would seem to be nearly closed by energy conservation requirements, given the existence of magnetic dipolar interactions among all SMM's in the crystal. Nevertheless, magnetic relaxation that is temperature independent has lately been observed for temperatures under 0.1 U/kBS for Fe8 and Mn12 (U ≈ 30 K and U ≈ 60 K, for Fe8 and Mn12, respectively, and S = 10 for both of them). Prokof'ev and Stamp (PS) were able to explain it by taking into account hyperfine interactions between the tunnelling electronic spins and nuclear spins. In the PS theory, the system of nuclear spins acts much as a heat bath providing a somewhat random magnetic field h(t) that acts on the otherwise closed system of interacting magnetic dipoles. Thus, the open nature of these systems plays an essential role in bringing tunnelling about. Their numerical simulations are explained, results that follow from the simulations are discussed, and a simple derivation of the tunnelling rate is given.

  7. Trapped magnetic field measurements on HTS bulk by peak controlled pulsed field magnetization

    International Nuclear Information System (INIS)

    Ida, Tetsuya; Watasaki, Masahiro; Kimura, Yosuke; Miki, Motohiro; Izumi, Mitsuru

    2010-01-01

    For the past several years, we have studied the high-temperature superconducting (HTS) synchronous motor assembled with melt-textured Gd-Ba-Cu-O bulk magnets. If the single pulse field magnetizes a bulk effectively, size of electrical motor will become small for the strong magnetic field of the HTS magnets without reducing output power of motor. In the previous study, we showed that the HTS bulk was magnetized to excellent cone-shape magnetic field distribution by using the waveform control pulse magnetization (WCPM) method. The WCPM technique made possible the active control of the waveform on which magnetic flux motion depended. We generated the pulse waveform with controlled risetime for HTS bulk magnetization to suppress the magnetic flux motion which decreases magnetization efficiency. The pulsed maximum magnetic flux density with slow risetime is not beyond the maximum magnetic flux density which is trapped by the static field magnetization. But, as for applying the pulse which has fast risetime, the magnetic flux which exceed greatly the threshold penetrates the bulk and causes the disorder of the trapped magnetic distribution. This fact suggests the possibility that the threshold at pulsed magnetization influences the dynamic magnetic flux motion. In this study, Gd-Ba-Cu-O bulk is magnetized by the controlled arbitrary trapezoidal shape pulse, of which the maximum magnetic flux density is controlled not to exceed the threshold. We will present the trapped magnetic characteristics and the technique to generate the controlled pulsed field.

  8. Magnetic separation technique for groundwater by five HTS melt-processed bulk magnets arranged in a line

    International Nuclear Information System (INIS)

    Oka, T.; Seki, H.; Kimura, T.; Mimura, D.; Fukui, S.; Ogawa, J.; Sato, T.; Ooizumi, M.; Fujishiro, H.; Hayashi, H.; Yokoyama, K.; Stiehler, C.

    2011-01-01

    A magnetic separation was practically conducted by 10-pole HTS bulk magnets. The HTS bulk magnets were activated to 2.5 T by feeding pulsed fields of 6 T. The separation ratio of actual groundwater exceeded 70% at less than 4.8 l/min. The flocks without magnetite powder were obviously attracted to the magnetic poles. A magnetic separation study for groundwater purification has been practically conducted by using the multi-pole magnet system. The magnetic pole was composed of 10 open magnetic spaces by arranging five HTS melt-processed bulk magnets in a line in a vacuum sheath. The individual bulk magnets were activated by feeding intense pulsed magnetic fields up to 6 T. The magnetic field distribution was estimated with respect to various pole arrangements. The actual groundwater samples of Sanjo City were processed so as to form large precipitates by adding the coagulant and pH controlling. The maximum separation ratio of the iron-bearing precipitates has exceeded over 70% when slurry water was exposed to 10 magnetic poles of up to 2.5 T at a flowing rate of less than 4.8 l/min. An obvious attraction of flocks to the magnetic poles was observed even when the water contains no magnetite powder at the flow rate of 1.01 l/min. This implies the validity of the multi-pole magnet system with respect to the actual application to water purification.

  9. Microsecond plasma opening switch experiments on GIT-4

    Energy Technology Data Exchange (ETDEWEB)

    Bystritskij, V M; Lisitsyn, I V; Sinebryukhov, A A; Sinebryukhov, V A [Russian Academy of Sciences, Tomsk (Russian Federation). Inst. of Electrophysics; Kim, A A; Kokshenev, V A; Koval` chuk, B M [Russian Academy of Sciences, Tomsk (Russian Federation). High Current Electronics Inst.

    1997-12-31

    The plasma opening switch (POS) operation at the current level up to 2 MA was studied at the terawatt power GIT-4 generator. The experiments are described in which the electrode diameter and the strength of the applied magnetic field were varied, and different plasma sources were used. It is shown that the high voltage / low impedance switch operation can be achieved if the linear current density at the POS cathode does not exceed 20 kA/cm. This value limits the maximum cathode diameter of the magnetically insulated transmission line. The anode diameter is limited by the requirement of no gap closure with a dense electrode plasma. The application of external magnetic field decreases the plasma density necessary for achieving a long POS conduction time operation regime. (J.U.). 1 tab., 4 refs.

  10. Microsecond plasma opening switch experiments on GIT-4

    International Nuclear Information System (INIS)

    Bystritskij, V.M.; Lisitsyn, I.V.; Sinebryukhov, A.A.; Sinebryukhov, V.A.; Kim, A.A.; Kokshenev, V.A.; Koval'chuk, B.M.

    1996-01-01

    The plasma opening switch (POS) operation at the current level up to 2 MA was studied at the terawatt power GIT-4 generator. The experiments are described in which the electrode diameter and the strength of the applied magnetic field were varied, and different plasma sources were used. It is shown that the high voltage / low impedance switch operation can be achieved if the linear current density at the POS cathode does not exceed 20 kA/cm. This value limits the maximum cathode diameter of the magnetically insulated transmission line. The anode diameter is limited by the requirement of no gap closure with a dense electrode plasma. The application of external magnetic field decreases the plasma density necessary for achieving a long POS conduction time operation regime. (J.U.). 1 tab., 4 refs

  11. THE RELATIONSHIP BETWEEN THE SEPTEMBER 2017 MARS GLOBAL AURORA EVENT AND CRUSTAL MAGNETIC FIELDS

    Science.gov (United States)

    Nasr, Camella-Rosa; Schneider, Nick; Connour, Kyle; Jain, Sonal; Deighan, Justin; Jakosky, Bruce; MAVEN/IUVS Team

    2018-01-01

    In September 2017, the Imaging UltraViolet Spectrograph (IUVS) on the MAVEN spacecraft observed global aurora on Mars caused by a surprisingly strong solar energetic particle event. Widespread “diffuse aurora” have previously been detected on Mars through more limited observations (Schneider et al., Science 350, (2015); DOI: 10.1126/science.aad0313), but recent observations established complete coverage of the observable portion of Mars’ nightside. The aurora was global due to Mars’s lack of a global magnetic field, which allowed energetic electrons from the Sun to directly precipitate into the atmosphere. On September 11th, IUVS detected aurora more than 25 times brighter than any prior IUVS observation, with high SNR detections of aurora at the limb and against the disk of the planet. Fainter auroral emission was seen around the nightside limb over 13 orbits spanning nearly 3 days.On September 14th, during the declining phase of the event, faint linear features and patches were detected by the spacecraft, which were higher than the noise floor, with a similar spatial distribution to “discrete aurora” patches observed on Mars by the SPICAM instrument on the Mars Express spacecraft (Bertaux et al., Nature 435, doi :10.1038/nature03603). Discrete aurora occur near areas of the crust affected by the magnetism left over from Mars’ once-strong dipole field. Emission is limited to regions of the crustal magnetic field where the field lines are likely to be open to solar wind interactions. Those regions are concentrated in Mars’ southern hemisphere centered on 180 degrees east longitude.We studied the localized emissions on 14 September to determine whether there might be a connection between the observed diffuse aurora event and discrete auroral processes. First, we investigated the localized emissions to confirm that the observed signal was consistent with expected auroral spectra. Second, their locations were projected on a map of the crustal magnetic

  12. On the location of dayside magnetic reconnection during an interval of duskward oriented IMF

    Directory of Open Access Journals (Sweden)

    J. A. Wild

    2007-02-01

    Full Text Available We present space- and ground-based observations of the signatures of magnetic reconnection during an interval of duskward-oriented interplanetary magnetic field on 25 March 2004. In situ field and plasma measurements are drawn from the Double Star and Cluster satellites during traversals of the pre-noon sector dayside magnetopause at low and high latitudes, respectively. These reveal the typical signatures of flux transfer events (FTEs, namely bipolar perturbations in the magnetic field component normal to the local magnetopause, enhancements in the local magnetic field strength and mixing of magnetospheric and magnetosheath plasmas. Further evidence of magnetic reconnection is inferred from the ground-based signatures of pulsed ionospheric flow observed over an extended interval. In order to ascertain the location of the reconnection site responsible for the FTEs, a simple model of open flux tube motion over the surface of the magnetopause is employed. A comparison of the modelled and observed motion of open flux tubes (i.e. FTEs and plasma flow in the magnetopause boundary layer indicates that the FTEs observed at both low and high latitudes were consistence with the existence of a tilted X-line passing through the sub-solar region, as suggested by the component reconnection paradigm. While a high latitude X-line (as predicted by the anti-parallel description of reconnection may have been present, we find it unlikely that it could have been responsible for the FTEs observed in the pre-noon sector under the observed IMF conditions. Finally, we note that throughout the interval, the magnetosphere was bathed in ULF oscillations within the solar wind electric field. While no one-to-one correspondence with the pulsed reconnection rate suggested by the ground-based observation of pulsed ionospheric flow has been demonstrated, we note that similar periodicity oscillations were observed throughout the solar wind-magnetosphere-ionosphere system. These

  13. Magneto-Ionic Control of Interfacial Magnetic Anisotorpy

    Science.gov (United States)

    Bauer, Uwe; Emori, Satoru; Beach, Geoffrey

    2014-03-01

    Voltage control of magnetism could bring about revolutionary new spintronic memory and logic devices. Here, we examine domain wall (DW) dynamics in ultrathin Co films and nanowires under the influence of a voltage applied across a gadolinium oxide gate dielectric that simultaneously acts as an oxygen ion conductor. We investigate two electrode configurations, one with a continuous gate dielectric and the other with a patterned gate dielectric which exhibits an open oxide edge right underneath the electrode perimeter. We demonstrate that the open oxide edge acts as a fast diffusion path for oxygen ions and allows voltage-induced switching of magnetic anisotropy at the nanoscale by modulating interfacial chemistry rather than charge density. At room temperature this effect is limited to the vicinity of the open oxide edge, but at a temperature of 100°C it allows complete control over magnetic anisotropy across the whole electrode area, due to higher oxygen ion mobility at elevated temperature. We then harness this novel ``magneto-ionic'' effect to create unprecedentedly strong voltage-induced anisotropy modifications of 3000 fJ/Vm and create electrically programmable DW traps with pinning strengths of 650 Oe, enough to bring to a standstill DWs travelling at speeds of at least 20 m/s. This work is supported by the National Science Foundation through grant ECCS-1128439.

  14. Embroidered Coils for Magnetic Resonance Sensors

    Directory of Open Access Journals (Sweden)

    Michael I. Newton

    2013-04-01

    Full Text Available Magnetic resonance imaging is a widely used technique for medical and materials imaging. Even though the objects being imaged are often irregularly shaped, suitable coils permitting the measurement of the radio-frequency signal in these systems are usually made of solid copper. One problem often encountered is how to ensure the coils are both in close proximity and conformal to the object being imaged. Whilst embroidered conductive threads have previously been used as antennae in mobile telecommunications applications, they have not previously been reported for use within magnetic resonance. In this paper we show that an embroidered single loop coil can be used in a commercial unilateral nuclear magnetic resonance system as an alternative to a solid copper. Data is presented showing the determination of both longitudinal (T1 and effective transverse (T2eff relaxation times for a flat fabric coil and the same coil conformed to an 8 cm diameter cylinder. We thereby demonstrate the principles required for the wider use of fabric based conformal coils within nuclear magnetic resonance and magnetic resonance imaging.

  15. Dabrafenib plus trametinib in patients with previously untreated BRAFV600E-mutant metastatic non-small-cell lung cancer: an open-label, phase 2 trial.

    Science.gov (United States)

    Planchard, David; Smit, Egbert F; Groen, Harry J M; Mazieres, Julien; Besse, Benjamin; Helland, Åslaug; Giannone, Vanessa; D'Amelio, Anthony M; Zhang, Pingkuan; Mookerjee, Bijoyesh; Johnson, Bruce E

    2017-10-01

    BRAF V600E mutation occurs in 1-2% of lung adenocarcinomas and acts as an oncogenic driver. Dabrafenib, alone or combined with trametinib, has shown substantial antitumour activity in patients with previously treated BRAF V600E -mutant metastatic non-small-cell lung cancer (NSCLC). We aimed to assess the activity and safety of dabrafenib plus trametinib treatment in previously untreated patients with BRAF V600E -mutant metastatic NSCLC. In this phase 2, sequentially enrolled, multicohort, multicentre, non-randomised, open-label study, adults (≥18 years of age) with previously untreated metastatic BRAF V600E -mutant NSCLC were enrolled into cohort C from 19 centres in eight countries within North America, Europe, and Asia. Patients received oral dabrafenib 150 mg twice per day plus oral trametinib 2 mg once per day until disease progression, unacceptable adverse events, consent withdrawal, or death. The primary endpoint was investigator-assessed overall response, defined as the percentage of patients who achieved a confirmed complete response or partial response per Response Evaluation Criteria In Solid Tumors version 1.1. The primary and safety analyses were by intention to treat in the protocol-defined population (previously untreated patients). The study is ongoing, but no longer recruiting patients. This trial is registered with ClinicalTrials.gov, number NCT01336634. Between April 16, 2014, and Dec 28, 2015, 36 patients were enrolled and treated with first-line dabrafenib plus trametinib. Median follow-up was 15·9 months (IQR 7·8-22·0) at the data cutoff (April 28, 2017). The proportion of patients with investigator-assessed confirmed overall response was 23 (64%, 95% CI 46-79), with two (6%) patients achieving a complete response and 21 (58%) a partial response. All patients had one or more adverse event of any grade, and 25 (69%) had one or more grade 3 or 4 event. The most common (occurring in more than two patients) grade 3 or 4 adverse events were

  16. Spin Hall driven domain wall motion in magnetic bilayers coupled by a magnetic oxide interlayer

    Science.gov (United States)

    Liu, Yang; Furuta, Masaki; Zhu, Jian-Gang Jimmy

    2018-05-01

    mCell, previously proposed by our group, is a four-terminal magnetoresistive device with isolated write- and read-paths for all-spin logic and memory applications. A mCell requires an electric-insulating magnetic layer to couple the spin Hall driven write-path to the magnetic free layer of the read-path. Both paths are magnetic layers with perpendicular anisotropy and their perpendicularly oriented magnetization needs to be maintained with this insertion layer. We have developed a magnetic oxide (FeOx) insertion layer to serve for these purposes. We show that the FeOx insertion layer provides sufficient magnetic coupling between adjacent perpendicular magnetic layers. Resistance measurement shows that this magnetic oxide layer can act as an electric-insulating layer. In addition, spin Hall driven domain wall motion in magnetic bi-layers coupled by the FeOx insertion layer is significantly enhanced compared to that in magnetic single layer; it also requires low voltage threshold that poses possibility for power-efficient device applications.

  17. Strain-Induced Pseudo--Magnetic Fields in Graphene: MegaGauss in Nanobubbles

    Science.gov (United States)

    Levy, Niv

    2011-03-01

    Recent theoretical proposals suggest that strain can be used to modify graphene electronic states through the creation of a pseudo--magnetic field. This effect is unique to graphene because of its massless Dirac fermion-like band structure and particular lattice symmetry (C3v). Scanning tunneling microscopy shows that graphene grown on a platinum (111) surface forms nanobubbles, which are highly strained due to thermal expansion mismatch between the film and the substrate. We find that scanning tunneling spectroscopy measurements of these nanobubbles exhibit Landau levels that form in the presence of strain-induced pseudo--magnetic fields greater than 300 Tesla. This demonstration of enormous pseudo--magnetic fields opens the door to both the study of charge carriers in previously inaccessible high magnetic field regimes and deliberate mechanical control over electronic structure in graphene or so-called ``strain engineering''. In collaboration with S. A. Burke ,2 , K. L. Meaker 2 , M. Panlasigui 2 , A. Zettl 2,3 , F. Guinea 4 , A. H. Castro Neto 5 and M. F. Crommie 2,3 . 1. Present address: Department of Physics and Astronomy and Department of Chemistry, University of British Columbia, Vancouver, BC V6T 121, Canada. 2. Department of Physics, University of California, Berkeley, CA 94720, USA. 3. Materials Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA. 4. Instituto de Ciencia de Materiales de Madrid (CSIC), Madrid 28049, Spain. 5. Department of Physics, Boston University, Boston, MA 02215, USA.

  18. Video-assisted open supraclavicular sympathectomy following air embolism.

    Science.gov (United States)

    Shpolyanski, G; Hashmonai, M; Rudin, M; Abaya, N; Kaplan, U; Kopelman, D

    2012-01-01

    Air embolism is a relatively rare complication of thoracoscopic surgery. Open supraclavicular sympathectomy was indicated to overcome the risk of re-embolization. A novel video-assisted technique was performed. conclusions: The previously prevalent open supraclavicular sympathectomy is a good choice for avoiding air embolism. Laparoscopic instrumentation and technology can be used to improve open procedures, especially when exposure and visibility are limited. Sometimes we should remember to use the experience of our teachers.

  19. Sensorless V/f Control of Permanent Magnet Synchronous Motors

    OpenAIRE

    Montesinos-Miracle, Daniel; Perera, P. D. Chandana; Galceran-Arellano, Samuel; Blaabjerg, Frede

    2010-01-01

    V/f control strategy for permanent magnet synchronous motors can be useful for HVAC applications, where not high performance is required. Permanent magnet synchronous motors have efficiency advantages over the induction motor. But open loop V/f control is not stable in the whole frequency range. As demonstrated, the V/f control strategy becomes

  20. APS extends open access to all its journals

    CERN Multimedia

    Thomas, Kim

    2006-01-01

    "Physics research promoter and publisher the American Physical Society (APS) is to extend open access to all its journals. Th APS previously made its five print journals available through subscriptions, and its two e-journals (Physical Review Special Topics and Physics Educatoin Research) on an open access basis." (1/2 page)

  1. The Behaviors of Ferro-Magnetic Nano-Particles In and Around Blood Vessels under Applied Magnetic Fields

    Science.gov (United States)

    Nacev, A.; Beni, C.; Bruno, O.; Shapiro, B.

    2010-01-01

    In magnetic drug delivery, therapeutic magnetizable particles are typically injected into the blood stream and magnets are then used to concentrate them to disease locations. The behavior of such particles in-vivo is complex and is governed by blood convection, diffusion (in blood and in tissue), extravasation, and the applied magnetic fields. Using physical first-principles and a sophisticated vessel-membrane-tissue (VMT) numerical solver, we comprehensively analyze in detail the behavior of magnetic particles in blood vessels and surrounding tissue. For any blood vessel (of any size, depth, and blood velocity) and tissue properties, particle size and applied magnetic fields, we consider a Krogh tissue cylinder geometry and solve for the resulting spatial distribution of particles. We find that there are three prototypical behaviors (blood velocity dominated, magnetic force dominated, and boundary-layer formation) and that the type of behavior observed is uniquely determined by three non-dimensional numbers (the magnetic-Richardson number, mass Péclet number, and Renkin reduced diffusion coefficient). Plots and equations are provided to easily read out which behavior is found under which circumstances (Figures 5, 6, 7, and 8). We compare our results to previously published in-vitro and in-vivo magnetic drug delivery experiments. Not only do we find excellent agreement between our predictions and prior experimental observations, but we are also able to qualitatively and quantitatively explain behavior that was previously not understood. PMID:21278859

  2. Optimal design method for magnetization directions of a permanent magnet array

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae Seok [Center for Information Storage Device, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of); Yoo, Jeonghoon, E-mail: yoojh@yonsei.ac.k [School of Mechanical Engineering, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of)

    2010-08-15

    In many magnetic systems, the permanent magnet (PM) pattern has a great influence on their performance. This study proposes a systematic optimization method for designing discrete magnetization directions. While previous works have been mostly dependent on researchers' intuition, the developed method is systematic and can be applied to a two-dimensional PM-type eddy current brake model. The effectiveness of the method is confirmed, where the design's aim is to maximize the braking force on a moving conductor. The sensitivity analysis is accomplished by the adjoint variable method and the sequential linear programming is used as an optimizer. Several optimization results for various conditions through the proposed design method are compared to each other and the optimal magnet configuration for an eddy current brake is suggested.

  3. Magnetic structure and microstructure of die-upset hard magnets RE13.75Fe80.25B6 (RE=Nd, Pr): A possible origin of high coercivity

    International Nuclear Information System (INIS)

    Volkov, V.V.; Zhu, Y.

    1999-01-01

    In situ transmission electron microscopy magnetizing experiments combined with Lorentz magnetic microscopy in Fresnel endash Foucault modes were used to characterize the magnetic structure of die-upset, high energy-product hard magnets Nd 13.75 Fe 80.25 B 6 and Pr 13.75 Fe 80.25 B 6 . Experimental observations indicate a well-aligned grain structure and quasiperiodic nonaligned open-quotes extended defectclose quotes layers transverse to press direction. The local remanence of the open-quotes defectclose quotes layers is far from saturation when the external field is removed. The layers are enriched with inclusions of approximate composition Nd 7 Fe 3 , generally with a polygonal shape, and are associated with the original ribbon interfaces. They may be responsible for a high coercivity mechanism, since the motion of reverse domains can be impeded by these layers, even when they are nucleated. Thus, a delayed nucleation of reversed domains seems to be a limiting factor for magnetization reversal and coercivity force. Both Lorentz magnetic imaging and high-resolution microscopy highlight the role of magnetocrystalline anisotropy for domain wall-grain boundary interactions and pinning. Local remanence was estimated directly from magnetic moment sensitive Foucault images. copyright 1999 American Institute of Physics

  4. 1000th magnet delivered!

    CERN Multimedia

    2006-01-01

    On Monday 20 February members of the AT Department marked the delivery of the 1000th superconducting dipole magnet to CERN. Only 232 more of the dipole magnets are needed for the LHC. The 35 tonne-dipoles are 15 meters long and are being manufactured by three companies: Babcock Noell Nuclear in Germany (which finished its contract in November 2005), Ansaldo Superconduttori in Italy and Alstom-Jeumont in France. "The production is proceeding well and we expect to be complete in October as previously foreseen," said Lucio Rossi, Head of the Magnets and Superconductors Group (AT-MAS). In total, 1650 main magnets are needed for the LHC, of which 1300 have been delivered.

  5. Coil-type Fano Resonances: a Plasmonic Approach to Magnetic Sub-diffraction Confinement

    KAUST Repository

    Panaro, Simone

    2015-05-10

    Matrices of nanodisk trimers are introduced as plasmonic platforms for the generation of localized magnetic hot-spots. In Fano resonance condition, the optical magnetic fields can be squeezed in sub-wavelength regions, opening promising scenarios for spintronics.

  6. Coil-type Fano Resonances: a Plasmonic Approach to Magnetic Sub-diffraction Confinement

    KAUST Repository

    Panaro, Simone; Nazir, Adnan; Zaccaria, Remo Proietti; Liberale, Carlo; De Angelis, Francesco; Toma, Andrea

    2015-01-01

    Matrices of nanodisk trimers are introduced as plasmonic platforms for the generation of localized magnetic hot-spots. In Fano resonance condition, the optical magnetic fields can be squeezed in sub-wavelength regions, opening promising scenarios for spintronics.

  7. Nanoscale magnetic ratchets based on shape anisotropy

    Science.gov (United States)

    Cui, Jizhai; Keller, Scott M.; Liang, Cheng-Yen; Carman, Gregory P.; Lynch, Christopher S.

    2017-02-01

    Controlling magnetization using piezoelectric strain through the magnetoelectric effect offers several orders of magnitude reduction in energy consumption for spintronic applications. However strain is a uniaxial effect and, unlike directional magnetic field or spin-polarized current, cannot induce a full 180° reorientation of the magnetization vector when acting alone. We have engineered novel ‘peanut’ and ‘cat-eye’ shaped nanomagnets on piezoelectric substrates that undergo repeated deterministic 180° magnetization rotations in response to individual electric-field-induced strain pulses by breaking the uniaxial symmetry using shape anisotropy. This behavior can be likened to a magnetic ratchet, advancing magnetization clockwise with each piezostrain trigger. The results were validated using micromagnetics implemented in a multiphysics finite elements code to simulate the engineered spatial and temporal magnetic behavior. The engineering principles start from a target device function and proceed to the identification of shapes that produce the desired function. This approach opens a broad design space for next generation magnetoelectric spintronic devices.

  8. Measurements of Cosmic Magnetism with LOFAR and SKA

    Directory of Open Access Journals (Sweden)

    R. Beck

    2007-06-01

    Full Text Available The origin of magnetic fields in stars, galaxies and clusters is an open problem in astrophysics. The next-generation radio telescopes Low Frequency Array (LOFAR and Square Kilometre Array (SKA will revolutionize the study of cosmic magnetism. "The origin and evolution of cosmic magnetism" is a key science project for SKA. The planned all-sky survey of Faraday rotation measures (RM at 1.4 GHz will be used to model the structure and strength of the magnetic fields in the intergalactic medium, the interstellar medium of intervening galaxies, and in the Milky Way. A complementary survey of selected regions at around 200 MHz is planned as a key project for LOFAR. Spectro-polarimetry applied to the large number of spectral channels available for LOFAR and SKA will allow to separate RM components from distinct foreground and background regions and to perform 3-D Faraday tomography of the interstellar medium of the Milky Way and nearby galaxies. – Deep polarization mapping with LOFAR and SKA will open a new era also in the observation of synchrotron emission from magnetic fields. LOFAR's sensitivity will allow to map the structure of weak, extended magnetic fields in the halos of galaxies, in galaxy clusters, and possibly in the intergalactic medium. Polarization observations with SKA at higher frequencies (1–10 GHz will show the detailed magnetic field structure within the disks and central regions of galaxies, with much higher angular resolution than present-day radio telescopes.

  9. Magnetic Fluxtube Tunneling

    Science.gov (United States)

    Dahlburg, Russell B.; Antiochos,, Spiro K.; Norton, D.

    1996-01-01

    We present numerical simulations of the collision and subsequent interaction of two initially orthogonal, twisted, force free field magnetic fluxtubes. The simulations were carried out using a new three dimensional explicit parallelized Fourier collocation algorithm for solving the viscoresistive equations of compressible magnetohydrodynamics. It is found that, under a wide range of conditions, the fluxtubes can 'tunnel' through each other. Two key conditions must be satisfied for tunneling to occur: the magnetic field must be highly twisted with a field line pitch much greater than 1, and the magnetic Lundquist number must be somewhat large, greater than or equal to 2880. This tunneling behavior has not been seen previously in studies of either vortex tube or magnetic fluxtube interactions. An examination of magnetic field lines shows that tunneling is due to a double reconnection mechanism. Initially orthogonal field lines reconnect at two specific locations, exchange interacting sections and 'pass' through each other. The implications of these results for solar and space plasmas are discussed.

  10. Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner

    Energy Technology Data Exchange (ETDEWEB)

    Wybranski, Christian [University Hospital of Cologne, Institute of Diagnostic and Interventional Radiology, Cologne (Germany); Adamchic, Ilya; Ricke, Jens; Fischbach, Frank; Fischbach, Katharina [Otto-von-Guericke University Medical School, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Roehl, Friedrich-Wilhelm [Otto-von-Guericke University Medical School, Institute of Biometry and Medical Informatics, Magdeburg (Germany)

    2017-01-15

    To assess the technical success and duration of magnetic resonance imaging (MRI)-guided freehand direct shoulder arthrography (FDSA) with near real-time imaging implemented in a routine shoulder MRI examination on an open 1.0-T MRI scanner, and to assess the learning curve of residents new to this technique. An experienced MRI interventionalist (the expert) performed 125 MRI-guided FDSA procedures, and 75 patients were treated by one of three residents without previous experience in MRI-guided FDSA. Technical success rate and duration of MRI-guided FDSA of the expert and the residents were compared. The residents' learning curves were assessed. The occurrence of extra-articular deposition and leakage of contrast media from the puncture site and the subsequent impairment of image interpretation were retrospectively analyzed. Overall technical success was 97.5 %. The expert needed overall fewer puncture needle readjustments and was faster at puncture needle positioning (p < 0.01). The learning curve of the residents, however, was steep. They leveled with the performance of the expert after ∼ 15 interventions. With a minimal amount of training all steps of MRI-guided FDSA can be performed in ≤10 min. Magnetic resonance-guided FDSA in an open 1.0-T MRI scanner can be performed with high technical success in a reasonably short amount of time. Only a short learning curve is necessary to achieve expert level. (orig.)

  11. MATLAB-based algorithm to estimate depths of isolated thin dike-like sources using higher-order horizontal derivatives of magnetic anomalies.

    Science.gov (United States)

    Ekinci, Yunus Levent

    2016-01-01

    This paper presents an easy-to-use open source computer algorithm (code) for estimating the depths of isolated single thin dike-like source bodies by using numerical second-, third-, and fourth-order horizontal derivatives computed from observed magnetic anomalies. The approach does not require a priori information and uses some filters of successive graticule spacings. The computed higher-order horizontal derivative datasets are used to solve nonlinear equations for depth determination. The solutions are independent from the magnetization and ambient field directions. The practical usability of the developed code, designed in MATLAB R2012b (MathWorks Inc.), was successfully examined using some synthetic simulations with and without noise. The algorithm was then used to estimate the depths of some ore bodies buried in different regions (USA, Sweden, and Canada). Real data tests clearly indicated that the obtained depths are in good agreement with those of previous studies and drilling information. Additionally, a state-of-the-art inversion scheme based on particle swarm optimization produced comparable results to those of the higher-order horizontal derivative analyses in both synthetic and real anomaly cases. Accordingly, the proposed code is verified to be useful in interpreting isolated single thin dike-like magnetized bodies and may be an alternative processing technique. The open source code can be easily modified and adapted to suit the benefits of other researchers.

  12. Dynamical quenching of tunneling in molecular magnets

    International Nuclear Information System (INIS)

    José Santander, María; Nunez, Alvaro S.; Roldán-Molina, A.; Troncoso, Roberto E.

    2015-01-01

    It is shown that a single molecular magnet placed in a rapidly oscillating magnetic field displays the phenomenon of quenching of tunneling processes. The results open a way to manipulate the quantum states of molecular magnets by means of radiation in the terahertz range. Our analysis separates the time evolution into slow and fast components thereby obtaining an effective theory for the slow dynamics. This effective theory presents quenching of the tunnel effect, in particular, stands out its difference with the so-called coherent destruction of tunneling. We support our prediction with numerical evidence based on an exact solution of Schrödinger's equation. - Highlights: • Single molecular magnets under rapidly oscillating magnetic fields is studied. • It is shown that this system displays the quenching of tunneling processes. • Our findings provide a control of quantum molecular magnets via terahertz radiation

  13. Dynamical quenching of tunneling in molecular magnets

    Energy Technology Data Exchange (ETDEWEB)

    José Santander, María, E-mail: maria.jose.noemi@gmail.com [Recursos Educativos Quántica, Santiago (Chile); Departamento de Física, Universidad de Santiago de Chile and CEDENNA, Avda. Ecuador 3493, Santiago (Chile); Nunez, Alvaro S., E-mail: alnunez@dfi.uchile.cl [Departamento de Física, Facultad de Ciencias Físicas y Matemáticas, Universidad de Chile, Casilla 487-3, Santiago (Chile); Roldán-Molina, A. [Instituto de Física, Pontificia Universidad Católica de Valparaíso, Avenida Universidad 330, Curauma, Valparaíso (Chile); Troncoso, Roberto E., E-mail: r.troncoso.c@gmail.com [Centro para el Desarrollo de la Nanociencia y la Nanotecnología, CEDENNA, Avda. Ecuador 3493, Santiago 9170124 (Chile); Departamento de Física, Universidad Técnica Federico Santa María, Avenida España 1680, Valparaíso (Chile)

    2015-12-15

    It is shown that a single molecular magnet placed in a rapidly oscillating magnetic field displays the phenomenon of quenching of tunneling processes. The results open a way to manipulate the quantum states of molecular magnets by means of radiation in the terahertz range. Our analysis separates the time evolution into slow and fast components thereby obtaining an effective theory for the slow dynamics. This effective theory presents quenching of the tunnel effect, in particular, stands out its difference with the so-called coherent destruction of tunneling. We support our prediction with numerical evidence based on an exact solution of Schrödinger's equation. - Highlights: • Single molecular magnets under rapidly oscillating magnetic fields is studied. • It is shown that this system displays the quenching of tunneling processes. • Our findings provide a control of quantum molecular magnets via terahertz radiation.

  14. Neutron oscillations and the primordial magnetic field

    International Nuclear Information System (INIS)

    Sarkar, S.

    1988-01-01

    It has been claimed that a primordial magnetic field must exist in order to suppress possible oscillations of neutrons into antineutrons which would otherwise affect the cosmological synthesis of helium. We demonstrate that such oscillations, even if they do occur, have a negligible effect on primordial nucleosynthesis, thus refuting the above claim. Hence the possible existence of a primordial magnetic field, relevant to current speculations concerning superconducting 'cosmic strings', remains an open question. (author)

  15. Magnetic field measurements of superconducting magnets for the colliding beam accelerator

    International Nuclear Information System (INIS)

    Herrera, J.; Kirk, H.; Prodell, A.; Willen, E.

    1983-01-01

    An important aspect of the development and production of superconducting magnets for the Colliding Beam Accelerator is the measurement of the magnetic field in the aperture of these magnets. The measurements have the three-fold purpose of determining the field quality as compared to the lattice requirements of the CBA, of obtaining the survey data necessary to position the magnets in the CBA tunnel, and lastly, of characterizing the magnetic fields for use in initial and future orbit studies of the CBA proton beams. Since for a superconducting storage accelerator it is necessary to carry out these detailed measurements on many (approx. 1000) magnets and at many current values (approx. 1000), we have chosen, in agreement with previous experience, to develop a system which Fourier analyses the voltages induced in a number of rotating windings and thereby obtains the multipole field components. The important point is that such a measuring system can be fast and precise. It has been used for horizontal measurements of the CBA ring dipoles

  16. OpenAPC. Open-Access-Publikationskosten als Open Data

    OpenAIRE

    Tullney, Marco

    2015-01-01

    Präsentationsfolien zum Vortrag „OpenAPC. Open-Access-Publikationskosten als Open Data“ in der Session „Ausgestaltung eines wissenschaftsadäquaten APC-Marktes: Grundsätze, Finanzierungsansätze und Management“ der Open-Access-Tage 2015 in Zürich (https://www.open-access.net/community/open-access-tage/open-access-tage-2015-zuerich/programm/#c1974)

  17. Open Days – The final countdown

    CERN Multimedia

    2008-01-01

    In only a few days CERN will open its doors to everyone! Thousands of volunteers are working very hard so that your visit will be both mind-boggling and fun. Where is the coldest place in the Universe? How can you move 30 tonne magnets with sub-millimetre precision? Why do you need huge detectors to look at the infinitely small? There’s only one way to find the answers: Come to CERN!

  18. The OAFM magnet for ISR intersection I-8

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    The Open Axial Field Magnet (OAFM), weighing in at 300 tons, was installed in ISR intersection I-8 and brought into operation early in 1979. Fitted with a highly transparent "flat-fish" vacuum chamber, it served experiment R807 (large transverse momentum). Flat-fish vacuum chambers were originally developed for use inside the Split-Field Magnet (SFM) at intersection I-4: see 8310325 and references there.

  19. Magnetic structure of RPdSn (R=Tb, Ho) single crystal compounds under strong magnetic field

    International Nuclear Information System (INIS)

    Andoh, Y.; Kurisu, M.; Nakamoto, G.; Tsutaoka, T.; Kawano, S.

    2003-01-01

    Rare earth compounds RTX, where R stands for rare earth elements, T for Ni, Pd or Rh, and X for Sn or Ge, crystallize to a rhombic ε-TiNiSi structure. Only rare earth elements R contribute to magnetic properties since T and X atoms are nonmagnetic. The competition between RKKY indirect interaction and large magnetic anisotropy generates many complicated magnetic phases. At a low temperature phase, complicated magnetisms such as meta-magnetism were observed in magnetization curves with many steps. In previous experiments dealing with RPdSn where R means Tb or Ho, some characteristics of magnetic properties of these compounds were deduced from magnetization measurements and neutron diffraction without external magnetic field. In this report, the change of magnetic scattering of neutron diffraction was studied under external magnetic fields in order to reveal the mechanism of the phase transformations of the compounds. The difference between TbPdSn and HoPdSn compounds was observed in magnetic field dependence of the wave vectors of the magnetic scattering. Two independent wave vectors in magnetic scattering existed in HoPdSn compound. (Y. Kazumata)

  20. Magnetic stability under magnetic cycling of MgO-based magnetic tunneling junctions with an exchange-biased synthetic antiferromagnetic pinned layer

    Directory of Open Access Journals (Sweden)

    Qiang Hao

    2016-02-01

    Full Text Available We investigate the magnetic stability and endurance of MgO-based magnetic tunnel junctions (MTJs with an exchange-biased synthetic antiferromagnetic (SAF pinned layer. When a uniaxially cycling switching field is applied along the easy axis of the free magnetic layer, the magnetoresistance varies only by 1.7% logarithmically with the number of cycles, while no such change appears in the case of a rotating field. This observation is consistent with the effect of the formation and motion of domain walls in the free layer, which create significant stray fields within the pinned hard layer. Unlike in previous studies, the decay we observed only occurs during the first few starting cycles (<20, at which point there is no further variance in all performance parameters up to 107 cycles. Exchange-biased SAF structure is ideally suited for solid-state magnetic sensors and magnetic memory devices.

  1. Magnetic nanoparticles and their application in biomedicine

    International Nuclear Information System (INIS)

    Felinto, M.C.F.C.; Camilo, R.L.; Diegues, T.G.

    2007-01-01

    The magnetic nanoparticles offer some attractive possibilities in biomedicine for the following reasons: First, they have controllable sizes ranging from a few nanometers up to tens of nanometers, which places them at dimensions that are smaller than or comparable to those of a cell (10-100μm) a virus (20-450 nm) or a protein (5-50 nm). Second, the nanoparticles are magnetic, which means that they obey Coulomb's law, and can be manipulated by an external magnetic field gradient. This possibility, combined with the intrinsic penetrability of magnetic fields into human tissue, opens up many applications involving the transport and/or immobilization of magnetic nanoparticles, or of magnetically tagged biological entities. Third, the magnetic nanoparticles can be made to resonantly respond to a time-varying magnetic field, with advantageous results related to the transfer of energy from the exciting field to the nanoparticle. In this paper, we will address the underlying chemical and physics of the biomedical applications of magnetic nanoparticles including radioisotope delivery and a magnetic radiolabeled fluid. We will consider four particular applications: magnetic separation for radio labeled proteins, drug radiolabeled delivery, hyperthermia treatments, and magnetic resonance imaging (MRI) contrast enhancement. There will be included some results obtained in our laboratory in the obtention of these magnetic (author)

  2. A global wave-driven magnetohydrodynamic solar model with a unified treatment of open and closed magnetic field topologies

    Energy Technology Data Exchange (ETDEWEB)

    Oran, R.; Van der Holst, B.; Landi, E.; Jin, M.; Sokolov, I. V.; Gombosi, T. I., E-mail: oran@umich.edu [Atmospheric, Oceanic and Atmospheric Sciences, University of Michigan, 2455 Hayward, Ann Arbor, MI, 48105 (United States)

    2013-12-01

    We describe, analyze, and validate the recently developed Alfvén Wave Solar Model, a three-dimensional global model starting from the top of the chromosphere and extending into interplanetary space (out to 1-2 AU). This model solves the extended, two-temperature magnetohydrodynamics equations coupled to a wave kinetic equation for low-frequency Alfvén waves. In this picture, heating and acceleration of the plasma are due to wave dissipation and to wave pressure gradients, respectively. The dissipation process is described by a fully developed turbulent cascade of counterpropagating waves. We adopt a unified approach for calculating the wave dissipation in both open and closed magnetic field lines, allowing for a self-consistent treatment in any magnetic topology. Wave dissipation is the only heating mechanism assumed in the model; no geometric heating functions are invoked. Electron heat conduction and radiative cooling are also included. We demonstrate that the large-scale, steady state (in the corotating frame) properties of the solar environment are reproduced, using three adjustable parameters: the Poynting flux of chromospheric Alfvén waves, the perpendicular correlation length of the turbulence, and a pseudoreflection coefficient. We compare model results for Carrington rotation 2063 (2007 November-December) with remote observations in the extreme-ultraviolet and X-ray ranges from the Solar Terrestrial Relations Observatory, Solar and Heliospheric Observatory, and Hinode spacecraft and with in situ measurements by Ulysses. The results are in good agreement with observations. This is the first global simulation that is simultaneously consistent with observations of both the thermal structure of the lower corona and the wind structure beyond Earth's orbit.

  3. Spin fluctuation theory of itinerant electron magnetism

    CERN Document Server

    Takahashi, Yoshinori

    2013-01-01

    This volume shows how collective magnetic excitations determine most of  the magnetic properties of itinerant electron magnets. Previous theories were mainly restricted to the Curie-Weiss law temperature dependence of magnetic susceptibilities. Based on the spin amplitude conservation idea including the zero-point fluctuation amplitude, this book shows that the entire temperature and magnetic field dependence of magnetization curves, even in the ground state, is determined by the effect of spin fluctuations. It also shows that the theoretical consequences are largely in agreement with many experimental observations. The readers will therefore gain a new comprehensive perspective of their unified understanding of itinerant electron magnetism.

  4. Open Standards, Open Source, and Open Innovation: Harnessing the Benefits of Openness

    Science.gov (United States)

    Committee for Economic Development, 2006

    2006-01-01

    Digitization of information and the Internet have profoundly expanded the capacity for openness. This report details the benefits of openness in three areas--open standards, open-source software, and open innovation--and examines the major issues in the debate over whether openness should be encouraged or not. The report explains each of these…

  5. Suppression of fast electron leakage from large openings in a plasma neutralizer for N-NB systems

    International Nuclear Information System (INIS)

    Kashiwagi, Mieko; Hanada, Masaya; Yamana, Takashi; Inoue, Takashi; Imai, Tsuyoshi; Taniguchi, Masaki; Watanabe, Kazuhiro

    2006-01-01

    To produce highly ionized plasmas at low operating pressure in a plasma neutralizer of negative ion based neutral beam (N-NB) systems, it is a critical issue to suppress leakage of fast electrons through large openings as the beam entrance/exit. The authors propose to form weak transverse magnetic fields without a significant beam deflection, called the shield field, across the large openings of the neutralizer. A numerical study showed that the shield field of only few tens of Gauss is sufficient to suppress the fast electron leakage from the openings. By measuring of an electron energy distribution function (EEDF), it was confirmed that such a weak magnetic field is enough to repel the fast electrons back into the neutralizer plasma. As the result, the plasma density increased with the shield field strength and saturated at 30 G. The plasma density reached 50% higher value than that without the shield field. Thus it was found that reflected fast electrons by the shield field of only 30 G work effectively for the plasma generation. It was also estimated that such a weak magnetic field sufficiently suppresses the deflection of a 1 MeV beam. This weak magnetic field would be applicable to the plasma neutralizer for the fusion demonstration (DEMO) plant

  6. Open problems in string cosmology

    International Nuclear Information System (INIS)

    Toumbas, N.

    2010-01-01

    Some of the open problems in string cosmology are highlighted within the context of the recently constructed thermal and quantum superstring cosmological solutions. Emphasis is given on the high temperature cosmological regime, where it is argued that thermal string vacua in the presence of gravito-magnetic fluxes can be used to bypass the Hagedorn instabilities of string gas cosmology. This article is based on a talk given at the workshop on ''Cosmology and Strings'', Corfu, September 6-13, 2009. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  7. Apparatus for efficient sidewall containment of molten metal with horizontal alternating magnetic fields utilizing a ferromagnetic dam

    Science.gov (United States)

    Praeg, Walter F.

    1997-01-01

    An apparatus for casting sheets of metal from molten metal. The apparatus includes a containment structure having an open side, a horizontal alternating magnetic field generating structure and a ferromagnetic dam. The magnetic field and the ferromagnetic dam contain the molten metal from leaking out side portions of the open side of the containment structure.

  8. The location of the open-closed magnetic field line boundary in the dawn sector auroral ionosphere

    Directory of Open Access Journals (Sweden)

    J. A. Wild

    2004-11-01

    Full Text Available As a measure of the degree of coupling between the solar wind-magnetosphere-ionosphere systems, the rate at which the size of the polar cap (the region corresponding to ionospheric termini of open magnetic flux tubes varies is of prime importance. However, a reliable technique by which the extent of the polar cap might be routinely monitored has yet to be developed. Current techniques provide particularly ambiguous indications of the polar cap boundary in the dawn sector. We present a case study of space- and ground-based observations of the dawn-sector auroral zone and attempt to determine the location of the polar cap boundary using multi-wavelength observations of the ultraviolet aurora (made by the IMAGE FUV imager, precipitating particle measurements (recorded by the FAST, DMSP, and Cluster 1 and 3 satellites, and SuperDARN HF radar observations of the ionospheric Doppler spectral width boundary. We conclude that in the dawn sector, during the interval presented, neither the poleward edge of the wideband auroral UV emission (140-180nm nor the Doppler spectral width boundary were trustworthy indicators of the polar cap boundary location, while narrow band UV emissions in the range 130-140nm appear to be much more reliable.

  9. Dynamics of the solar magnetic field. V. Velocities associated with changing magnetic fields

    International Nuclear Information System (INIS)

    Levine, R.H.; Nakagawa, Y.

    1975-01-01

    Methods of determining horizontal velocities from the magnetic induction equation on the basis of a time series of magnetogram observations are discussed. For the flare of 1972 August 7, it is shown that a previously developed method of predicting positions of likely flare activity provides reasonable agreement with observations. Limitations to this type of solution of the magnetic induction equation are pointed out, and unambiguous solutions, corresponding to phenomenological determinations of velocity patterns under various physical circumstances, are presented for simple magnetic configurations. Implications for the analysis of changes in a series of magnetogram observations are discussed

  10. Permanent magnets in accelerators can save energy, space and cost

    DEFF Research Database (Denmark)

    Bødker, F.; Baandrup, L.O.; Hauge, N.

    2013-01-01

    coils permit fine tuning of the magnetic field. Magnetic field measurements and thermal stability tests show that the Green Magnet fully meets the magnetic requirements of the previously used electromagnet. A permanent 30° bending dipole is currently being development to demonstrate the use of Green...

  11. The Effect of Magnetic Topology on the Escape of Flare Particles

    Science.gov (United States)

    Antiochos, S. K.; Masson, S.; DeVore, C. R.

    2012-01-01

    Magnetic reconnection in the solar atmosphere is believed to be the driver of most solar explosive phenomena. Therefore, the topology of the coronal magnetic field is central to understanding the solar drivers of space weather. Of particular importance to space weather are the impulsive Solar Energetic particles that are associated with some CME/eruptive flare events. Observationally, the magnetic configuration of active regions where solar eruptions originate appears to agree with the standard eruptive flare model. According to this model, particles accelerated at the flare reconnection site should remain trapped in the corona and the ejected plasmoid. However, flare-accelerated particles frequently reach the Earth long before the CME does. We present a model that may account for the injection of energetic particles onto open magnetic flux tubes connecting to the Earth. Our model is based on the well-known 2.5D breakout topology, which has a coronal null point (null line) and a four-flux system. A key new addition, however, is that we include an isothermal solar wind with open-flux regions. Depending on the location of the open flux with respect to the null point, we find that the flare reconnection can consist of two distinct phases. At first, the flare reconnection involves only closed field, but if the eruption occurs close to the open field, we find a second phase involving interchange reconnection between open and closed. We argue that this second reconnection episode is responsible for the injection of flare-accelerated particles into the interplanetary medium. We will report on our recent work toward understanding how flare particles escape to the heliosphere. This work uses high-resolution 2.5D MHD numerical simulations performed with the Adaptively Refined MHD Solver (ARMS).

  12. Electron temperature in field reversed configurations and theta pinches with closed magnetic field lines

    International Nuclear Information System (INIS)

    Newton, A.A.

    1986-01-01

    Field-reversed configurations (FRC) and theta pinches with trapped reversed bias field are essentially the same magnetic confinement systems using closed magnetic field lines inside an open-ended magnetic flux tube. A simple model of joule heating and parallel electron thermal conduction along the open flux lines to an external heat sink gives the electron temperature as Tsub(e)(eV) approx.= 0.05 Bsup(2/3)(G)Lsup(1/3)(cm), where B is the magnetic field and L is the coil length. This model appears to agree with measurements from present FRC experiments and past theta-pinch experiments which cover a range of 40-900 eV. The energy balance in the model is dominated by (a) parallel electron thermal conduction along the open field lines which has a steep temperature dependence, Q is proportional to Tsub(e)sup(7/2), and (b) the assumed rapid perpendicular transport in the plasma bulk which, in experiments to date, may be due to the small number of ion gyroradii across the plasma. (author)

  13. Topology optimized permanent magnet systems

    Science.gov (United States)

    Bjørk, R.; Bahl, C. R. H.; Insinga, A. R.

    2017-09-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a Λcool figure of merit of 0.472 is reached, which is an increase of 100% compared to a previous optimized design.

  14. A GLOBAL MAGNETIC TOPOLOGY MODEL FOR MAGNETIC CLOUDS. II

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, M. A., E-mail: miguel.hidalgo@uah.es [Departamento de Fisica, Universidad de Alcala, Apartado 20, E-28871 Alcala de Henares, Madrid (Spain)

    2013-04-01

    In the present work, we extensively used our analytical approach to the global magnetic field topology of magnetic clouds (MCs), introduced in a previous paper, in order to show its potential and to study its physical consistency. The model assumes toroidal topology with a non-uniform (variable maximum radius) cross-section along them. Moreover, it has a non-force-free character and also includes the expansion of its cross-section. As is shown, the model allows us, first, to analyze MC magnetic structures-determining their physical parameters-with a variety of magnetic field shapes, and second, to reconstruct their relative orientation in the interplanetary medium from the observations obtained by several spacecraft. Therefore, multipoint spacecraft observations give the opportunity to infer the structure of this large-scale magnetic flux rope structure in the solar wind. For these tasks, we use data from Helios (A and B), STEREO (A and B), and Advanced Composition Explorer. We show that the proposed analytical model can explain quite well the topology of several MCs in the interplanetary medium and is a good starting point for understanding the physical mechanisms under these phenomena.

  15. Evidence for extreme divergence of open field lines from solar activity

    International Nuclear Information System (INIS)

    Dulk, G.A.; Suzuki, S.; Melrose, D.B.

    1979-01-01

    This paper reviews the evidence on the structure of the open magnetic field lines that emerge from solar active regions into interplanetary space. The evidence comes mainly from the measured sizes, positions and polarization of Type III and Type V bursts, and from electron streams observed from space. It is found that the observations are best interpreted in terms of a strongly-diverging field topology, with the open field lines filling a cone of angle approx. 60 0

  16. Magnetic interaction reversal in watermelon nanostructured Cr-doped Fe nanoclusters

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Maninder; Dai, Qilin; Bowden, Mark; Engelhard, Mark; Wu, Yaqiao; Tang, Jinke; Qiang, You

    2013-01-01

    Cr-doped core-shell Fe/Fe-oxide nanoclusters (NCs) were synthesized at varied atomic percentages of Cr from 0 at. % to 8 at. %. The low concentrations of Cr (<10 at. %) were selected in order to inhibit the complete conversion of the Fe-oxide shell to Cr2O3 and the Fe core to FeCr alloy. The magnetic interaction in Fe/Fe-oxide NCs (rv25 nm) can be controlled by antiferromagnetic Cr-dopant. We report the origin of r-FeCr phase at very low Cr concentration (2 at. %) unlike in previous studies, and the interaction reversal from dipolar to exchange interaction in watermelon-like Cr-doped core-shell NCs. The giant magnetoresistance (GMR) effect,1,2 where an antiferromagnetic (AFM) exchange coupling exists between two ferromagnetic (FM) layers separated by a certain type of magnetic or non-magnetic spacer,3 has significant potential for application in the magnetic recording industry. Soon after the discovery of the GMR, the magnetic properties of multilayer systems (FeCr) became a subject of intensive study. The application of bulk iron-chromium (Fe-Cr) alloys has been of great interest, as these alloys exhibit favorable prop- erties including corrosion resistance, high strength, hardness, low oxidation rate, and strength retention at elevated temper- ature. However, the structural and magnetic properties of Cr-doped Fe nanoclusters (NCs) have not been investigated in-depth. Of all NCs, Fe-based clusters have unique magnetic properties as well as favorable catalytic characteristics in reactivity, selectivity, and durability.4 The incorporation of dopant of varied type and concentration in Fe can modify its chemical ordering, thereby optimizing its electrical, optical, and magnetic properties and opening up many new applications. The substitution of an Fe atom (1.24 A°) by a Cr atom (1.25 A° ) can easily modify the magnetic properties, since (i) the curie temperature (Tc ) of Fe is 1043 K, while Cr is an itinerant AFM with a bulk Neel temperature TN =311 K, and (ii) Fe

  17. Random Interchange of Magnetic Connectivity

    Science.gov (United States)

    Matthaeus, W. H.; Ruffolo, D. J.; Servidio, S.; Wan, M.; Rappazzo, A. F.

    2015-12-01

    Magnetic connectivity, the connection between two points along a magnetic field line, has a stochastic character associated with field lines random walking in space due to magnetic fluctuations, but connectivity can also change in time due to dynamical activity [1]. For fluctuations transverse to a strong mean field, this connectivity change be caused by stochastic interchange due to component reconnection. The process may be understood approximately by formulating a diffusion-like Fokker-Planck coefficient [2] that is asymptotically related to standard field line random walk. Quantitative estimates are provided, for transverse magnetic field models and anisotropic models such as reduced magnetohydrodynamics. In heliospheric applications, these estimates may be useful for understanding mixing between open and close field line regions near coronal hole boundaries, and large latitude excursions of connectivity associated with turbulence. [1] A. F. Rappazzo, W. H. Matthaeus, D. Ruffolo, S. Servidio & M. Velli, ApJL, 758, L14 (2012) [2] D. Ruffolo & W. Matthaeus, ApJ, 806, 233 (2015)

  18. Selective Induction of Optical Magnetism.

    Science.gov (United States)

    Manna, Uttam; Lee, Jung-Hoon; Deng, Tian-Song; Parker, John; Shepherd, Nolan; Weizmann, Yossi; Scherer, Norbert F

    2017-12-13

    An extension of the Maxwell-Faraday law of electromagnetic induction to optical frequencies requires spatially appropriate materials and optical beams to create resonances and excitations with curl. Here we employ cylindrical vector beams with azimuthal polarization to create electric fields that selectively drive magnetic responses in dielectric core-metal nanoparticle "satellite" nanostructures. These optical frequency magnetic resonances are induced in materials that do not possess spin or orbital angular momentum. Multipole expansion analysis of the scattered fields obtained from electrodynamics simulations show that the excitation with azimuthally polarized beams selectively enhances magnetic vs electric dipole resonances by nearly 100-fold in experiments. Multipolar resonances (e.g., quadrupole and octupole) are enhanced 5-fold by focused azimuthally versus linearly polarized beams. We also selectively excite electric multipolar resonances in the same identical nanostructures with radially polarized light. This work opens new opportunities for spectroscopic investigation and control of "dark modes", Fano resonances, and magnetic modes in nanomaterials and engineered metamaterials.

  19. Closed and open magnetic fields in stellar winds

    Science.gov (United States)

    Mullan, D. J.; Steinolfson, R. S.

    1983-01-01

    A numerical study of the interaction between a thermal wind and a global dipole field in the sun and in a giant star is reported. In order for closed field lines to persist near the equator (where a helmet-streamer-like configuration appears), the coronal temperature must be less than a critical value Tc, which scales as M/R. This condition is found to be equivalent to the following: for a static helmet streamer to persist, the sonic point above the helmet must not approach closer to the star than 2.2-2.6 stellar radii. Implications for rapid mass loss and X-ray emission from cool giants are pointed out. The results strengthen the case for identifying empirical dividing lines in the H-R diagram with a magnetic topology transition locus (MTTL). Support for the MTTL concept is also provided by considerations of the breakdown of magnetostatic equilibrium.

  20. Exploratory Spectroscopy of Magnetic Cataclysmic Variables Candidates and Other Variable Objects

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, A. S.; Palhares, M. S. [IP and D, Universidade do Vale do Paraíba, 12244-000, São José dos Campos, SP (Brazil); Rodrigues, C. V.; Cieslinski, D.; Jablonski, F. J. [Divisão de Astrofísica, Instituto Nacional de Pesquisas Espaciais, 12227-010, São José dos Campos, SP (Brazil); Silva, K. M. G. [Gemini Observatory, Casilla 603, La Serena (Chile); Almeida, L. A. [Instituto de Astronomia, Geofísica e Ciências Atmosféricas, Universidade de São Paulo, 05508-900, São Paulo, SP (Brazil); Rodríguez-Ardila, A., E-mail: alexandre@univap.br [Laboratório Nacional de Astrofísica LNA/MCTI, 37504-364, Itajubá MG (Brazil)

    2017-04-01

    The increasing number of synoptic surveys made by small robotic telescopes, such as the photometric Catalina Real-Time Transient Survey (CRTS), provides a unique opportunity to discover variable sources and improves the statistical samples of such classes of objects. Our goal is the discovery of magnetic Cataclysmic Variables (mCVs). These are rare objects that probe interesting accretion scenarios controlled by the white-dwarf magnetic field. In particular, improved statistics of mCVs would help to address open questions on their formation and evolution. We performed an optical spectroscopy survey to search for signatures of magnetic accretion in 45 variable objects selected mostly from the CRTS. In this sample, we found 32 CVs, 22 being mCV candidates, 13 of which were previously unreported as such. If the proposed classifications are confirmed, it would represent an increase of 4% in the number of known polars and 12% in the number of known IPs. A fraction of our initial sample was classified as extragalactic sources or other types of variable stars by the inspection of the identification spectra. Despite the inherent complexity in identifying a source as an mCV, variability-based selection, followed by spectroscopic snapshot observations, has proved to be an efficient strategy for their discoveries, being a relatively inexpensive approach in terms of telescope time.

  1. Magnetic nanowires and hyperthermia: How geometry and material affect heat production efficiency

    KAUST Repository

    Contreras, Maria F.; Zaher, A.; Perez, Jose E.; Ravasi, Timothy; Kosel, Jü rgen

    2015-01-01

    Magnetic hyperthermia, which refers to the production of heat by magnetic nanostructures under an alternating magnetic field (AMF), has been previously investigated with superparamagnetic nanobeads as a cancer therapy method. Magnetic nanowires (NWs

  2. Open midplane designs based on sector coils in superconducting dipoles

    CERN Document Server

    Bruer, J

    2009-01-01

    This paper presents a study of the effects of opening up the midplane in conventional sector coil dipoles, also known as cosè-designs. The open midplane design is a candidate for the higher luminosity upgrade for the LHC, and also for the future beta beam project at CERN, which has the heat deposition mainly concentrated in the midplane of the dipoles. By opening up the midplane, the major part of the spray particles can be avoided, allowing the use of strong superconductive magnets. The aim of this study is to maintain good field quality after a gap in the midplane has been inserted. Short sample field and the electromagnetic force distribution will also be presented for some solutions.

  3. Magnetic Reconnection Results on the Swarthmore Spheromak Experiment

    Science.gov (United States)

    Kornack, T. W.; Sollins, P. K.; Brown, M. R.

    1997-11-01

    Linear and 2D arrays of magnetic probes are used to study magnetic reconnection in the Swarthmore Spheromak Experiment (SSX). Opposing coaxial plasma guns form two identical spheromaks into adjacent 0.5 m diameter copper flux conservers. The flux conservers have symmetrical openings that allow the spheromaks to merge in a controlled manner. The stable equilibrium of the spheromaks provides a reservoir of magnetic flux for reconnection experiments. Currently, the magnetic configuration of the spheromaks allows the study of counter-helicity reconnection. Preliminary analysis will be presented and may include 2D B field movies of the reconnection region, measurement of the reconnection rate and comparison to the Sweet-Parker and standard Petschek models.

  4. Hinged and sectional complete dentures for restricted mouth opening: A case report and review

    Directory of Open Access Journals (Sweden)

    Aditi Sharma

    2013-01-01

    Full Text Available Restricted mouth opening is a definite prosthodontic hindrance to carry out treatment successfully. Restricted mouth opening can be due to many reasons such as microstomia, oral submucous fibrosis, some genetic disorder, and as a result of some surgical treatment. In the past, various techniques for prosthetic rehabilitation of limited oral opening have been tried such as surgeries, use of dynamic opening devices, magnetic devices, and modification of denture design. Here we present; a simplified technique and simple design for fabrication of maxillary hinged and mandibular hinged and sectional complete denture for a patient with restricted mouth opening due to oral submucous fibrosis.

  5. Effect of benzalkonium chloride?free travoprost on intraocular pressure and ocular surface symptoms in patients with glaucoma previously on latanoprost: an open-label study

    OpenAIRE

    Lopes, Joao F.; Hubatsch, Douglas A.; Amaris, Patricia

    2015-01-01

    Background Prostaglandin analogs reduce intraocular pressure (IOP) in patients with open-angle glaucoma or ocular hypertension; however, these medications may affect the ocular surface and elicit ocular discomfort when preserved with benzalkonium chloride (BAK). Methods This was an open-label, single-arm study conducted in Latin America from February 2012 to May 2013. Patients with open-angle glaucoma or ocular hypertension who were intolerant of latanoprost 0.005?% were transitioned to recei...

  6. Open and partially closed models of the solar wind interaction with outer planet magnetospheres. The case of Saturn

    Energy Technology Data Exchange (ETDEWEB)

    Belenkaya, Elena S.; Alexeev, Igor I.; Kalegaev, Vladimir V.; Pensionerov, Ivan A.; Blokhina, Marina S.; Parunakian, David A. [Federal State Budget Educational Institution of Higher Education M.V. Lomonosov Moscow State Univ., Moscow (Russian Federation). Skobeltsyn Inst. of Nuclear Physics (SINP MSU); Cowley, Stanley W. H. [Leicester Univ. (United Kingdom). Dept. of Physics and Astronomy

    2017-07-01

    A wide variety of interactions take place between the magnetized solar wind plasma outflow from the Sun and celestial bodies within the solar system. Magnetized planets form magnetospheres in the solar wind, with the planetary field creating an obstacle in the flow. The reconnection efficiency of the solar-wind-magnetized planet interaction depends on the conditions in the magnetized plasma flow passing the planet. When the reconnection efficiency is very low, the interplanetary magnetic field (IMF) does not penetrate the magnetosphere, a condition that has been widely discussed in the recent literature for the case of Saturn. In the present paper, we study this issue for Saturn using Cassini magnetometer data, images of Saturn's ultraviolet aurora obtained by the HST, and the paraboloid model of Saturn's magnetospheric magnetic field. Two models are considered: first, an open model in which the IMF penetrates the magnetosphere, and second, a partially closed model in which field lines from the ionosphere go to the distant tail and interact with the solar wind at its end. We conclude that the open model is preferable, which is more obvious for southward IMF. For northward IMF, the model calculations do not allow us to reach definite conclusions. However, analysis of the observations available in the literature provides evidence in favor of the open model in this case too. The difference in magnetospheric structure for these two IMF orientations is due to the fact that the reconnection topology and location depend on the relative orientation of the IMF vector and the planetary dipole magnetic moment. When these vectors are parallel, two-dimensional reconnection occurs at the low-latitude neutral line. When they are antiparallel, three-dimensional reconnection takes place in the cusp regions. Different magnetospheric topologies determine different mapping of the open-closed boundary in the ionosphere, which can be considered as a proxy for the poleward edge

  7. Octupolar out-of-plane magnetic field structure generation during collisionless magnetic reconnection in a stressed X-point collapse

    Energy Technology Data Exchange (ETDEWEB)

    Graf von der Pahlen, J.; Tsiklauri, D. [School of Physics and Astronomy, Queen Mary University of London, London E1 4NS (United Kingdom)

    2014-06-15

    The out-of-plane magnetic field, generated by fast magnetic reconnection, during collisionless, stressed X-point collapse, was studied with a kinetic, 2.5D, fully electromagnetic, relativistic particle-in-cell numerical code, using both closed (flux conserving) and open boundary conditions on a square grid. It was discovered that the well known quadrupolar structure in the out-of-plane magnetic field gains four additional regions of opposite magnetic polarity, emerging near the corners of the simulation box, moving towards the X-point. The emerging, outer, magnetic field structure has opposite polarity to the inner quadrupolar structure, leading to an overall octupolar structure. Using Ampere's law and integrating electron and ion currents, defined at grid cells, over the simulation domain, contributions to the out-of-plane magnetic field from electron and ion currents were determined. The emerging regions of opposite magnetic polarity were shown to be the result of ion currents. Magnetic octupolar structure is found to be a signature of X-point collapse, rather than tearing mode, and factors relating to potential discoveries in experimental scenarios or space-craft observations are discussed.

  8. Fallback accretion onto magnetized neutron stars and the hidden magnetic field model

    International Nuclear Information System (INIS)

    Torres, A; Cerdá-Durán, P; Font, J A

    2015-01-01

    The observation of several neutron stars with relatively low values of the surface magnetic field found in supernova remnants has led in recent years to controversial interpretations. A possible explanation is the slow rotation of the proto-neutron star at birth which is unable to amplify its magnetic field to typical pulsar levels. An alternative possibility, the hidden magnetic field scenario, seems to be favoured over the previous one due to the observation of three low magnetic field magnetars. This scenario considers the accretion of the fallback of the supernova debris onto the neutron star as the responsible for the observed low magnetic field. In this work, we have studied under which conditions the magnetic field of a neutron star can be buried into the crust due to an accreting fluid. We have considered a simplified toy model in general relativity to estimate the balance between the incoming accretion flow an the magnetosphere. We conclude that the burial is possible for values of the surface magnetic field below 10 13 G. The preliminary results reported in this paper for simplified polytropic models should be confirmed using a more realistic thermodynamical setup. (paper)

  9. Tuning the stability and the skyrmion Hall effect in magnetic skyrmions by adjusting their exchange strengths with magnetic disks

    Science.gov (United States)

    Sun, L.; Wu, H. Z.; Miao, B. F.; Wu, D.; Ding, H. F.

    2018-06-01

    Magnetic skyrmion is a promising candidate for the future information technology due to its small size, topological protection and the ultralow current density needed to displace it. The applications, however, are currently limited by its narrow phase diagram and the skyrmion Hall effect which prevents the skyrmion motion at high speed. In this work, we study the Dzyaloshinskii-Moriya interaction induced magnetic skyrmion that exchange coupled with magnetic nano-disks utilizing the micromagnetic simulation. We find that the stability and the skyrmion Hall effect of the created skyrmion can be tuned effectively with the coupling strength, thus opens the space to optimize the performance of the skyrmion based devices.

  10. Nanoscale magnetic field mapping with a single spin scanning probe magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Rondin, L.; Tetienne, J.-P.; Spinicelli, P.; Roch, J.-F.; Jacques, V. [Laboratoire de Photonique Quantique et Moleculaire, Ecole Normale Superieure de Cachan and CNRS UMR 8537, 94235 Cachan Cedex (France); Dal Savio, C.; Karrai, K. [Attocube systems AG, Koeniginstrasse 11A RGB, Munich 80539 (Germany); Dantelle, G. [Laboratoire de Physique de la Matiere Condensee, Ecole Polytechnique and CNRS UMR 7643, 91128 Palaiseau (France); Thiaville, A.; Rohart, S. [Laboratoire de Physique des Solides, Universite Paris-Sud and CNRS UMR 8502, 91405 Orsay (France)

    2012-04-09

    We demonstrate quantitative magnetic field mapping with nanoscale resolution, by applying a lock-in technique on the electron spin resonance frequency of a single nitrogen-vacancy defect placed at the apex of an atomic force microscope tip. In addition, we report an all-optical magnetic imaging technique which is sensitive to large off-axis magnetic fields, thus extending the operation range of diamond-based magnetometry. Both techniques are illustrated by using a magnetic hard disk as a test sample. Owing to the non-perturbing and quantitative nature of the magnetic probe, this work should open up numerous perspectives in nanomagnetism and spintronics.

  11. A trinuclear radical-bridged lanthanide single-molecule magnet

    Energy Technology Data Exchange (ETDEWEB)

    Gould, Colin A.; Darago, Lucy E.; Gonzalez, Miguel I. [Department of Chemistry, University of California, Berkeley, CA (United States); Demir, Selvan [Institut fuer Anorganische Chemie, Georg-August-Universitaet, Goettingen (Germany); Long, Jeffrey R. [Department of Chemistry, University of California, Berkeley, CA (United States); Department of Chemical and Biomolecular Engineering, University of California, Berkeley, CA (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2017-08-14

    Assembly of the triangular, organic radical-bridged complexes Cp*{sub 6}Ln{sub 3}(μ{sub 3}-HAN) (Cp*=pentamethylcyclopentadienyl; Ln=Gd, Tb, Dy; HAN=hexaazatrinaphthylene) proceeds through the reaction of Cp*{sub 2}Ln(BPh{sub 4}) with HAN under strongly reducing conditions. Significantly, magnetic susceptibility measurements of these complexes support effective magnetic coupling of all three Ln{sup III} centers through the HAN{sup 3-.} radical ligand. Thorough investigation of the Dy{sup III} congener through both ac susceptibility and dc magnetic relaxation measurements reveals slow relaxation of the magnetization, with an effective thermal relaxation barrier of U{sub eff}=51 cm{sup -1}. Magnetic coupling in the Dy{sup III} complex enables a large remnant magnetization at temperatures up to 3.0 K in the magnetic hysteresis measurements and hysteresis loops that are open at zero-field up to 3.5 K. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. A permanent magnet system for Kibble balances

    Science.gov (United States)

    Li, Shisong; Bielsa, Franck; Stock, Michael; Kiss, Adrien; Fang, Hao

    2017-10-01

    The magnet is one of the fundamental elements in Kibble balances. The Kibble balance group at the Bureau International des Poids et Mesures (BIPM) proposed a permanent magnet with a radial field, which has been widely employed in other Kibble balance experiments. In this paper, we discuss a different method of operation for the BIPM-type magnet, i.e. only the lower half of the magnetic circuit is closed. The merit of such a magnet is its convenience for opening the air gap and adjusting the coil. A disadvantage is that it can yield a lower and sloped magnetic field profile with less shielding. In the approach described, high permeability yokes are used to flatten the magnetic profile, which has proven to be a novel and convenient approach for removing the nonuniformity of the magnetic profile due to magnet magnetization asymmetries. The performance of the half-closed BIPM magnet is evaluated using experimental measurements. The results show that the half-closed magnetic circuit retains most of the main features of the fully-closed magnet and is a good option for the early stages of Kibble balance operations. In addition, the profile change due to the coil current is predicted and experimentally verified with a bifilar coil. Related systematic effects are discussed for the Planck constant measurement.

  13. Magneto-conductance fingerprints of purely quantum states in the open quantum dot limit

    Science.gov (United States)

    Mendoza, Michel; Ujevic, Sebastian

    2012-06-01

    We present quantum magneto-conductance simulations, at the quantum low energy condition, to study the open quantum dot limit. The longitudinal conductance G(E,B) of spinless and non-interacting electrons is mapped as a function of the magnetic field B and the energy E of the electrons. The quantum dot linked to the semi-infinite leads is tuned by quantum point contacts of variable width w. We analyze the transition from a quantum wire to an open quantum dot and then to an effective closed system. The transition, as a function of w, occurs in the following sequence: evolution of quasi-Landau levels to Fano resonances and quasi-bound states between the quasi-Landau levels, followed by the formation of crossings that evolve to anti-crossings inside the quasi-Landau level region. After that, Fano resonances are created between the quasi-Landau states with the final generation of resonant tunneling peaks. By comparing the G(E,B) maps, we identify the closed and open-like limits of the system as a function of the applied magnetic field. These results were used to build quantum openness diagrams G(w,B). Also, these maps allow us to determine the w-limit value from which we can qualitatively relate the closed system properties to the open one. The above analysis can be used to identify single spinless particle effects in experimental measurements of the open quantum dot limit.

  14. Magneto-conductance fingerprints of purely quantum states in the open quantum dot limit

    International Nuclear Information System (INIS)

    Mendoza, Michel; Ujevic, Sebastian

    2012-01-01

    We present quantum magneto-conductance simulations, at the quantum low energy condition, to study the open quantum dot limit. The longitudinal conductance G(E,B) of spinless and non-interacting electrons is mapped as a function of the magnetic field B and the energy E of the electrons. The quantum dot linked to the semi-infinite leads is tuned by quantum point contacts of variable width w. We analyze the transition from a quantum wire to an open quantum dot and then to an effective closed system. The transition, as a function of w, occurs in the following sequence: evolution of quasi-Landau levels to Fano resonances and quasi-bound states between the quasi-Landau levels, followed by the formation of crossings that evolve to anti-crossings inside the quasi-Landau level region. After that, Fano resonances are created between the quasi-Landau states with the final generation of resonant tunneling peaks. By comparing the G(E,B) maps, we identify the closed and open-like limits of the system as a function of the applied magnetic field. These results were used to build quantum openness diagrams G(w,B). Also, these maps allow us to determine the w-limit value from which we can qualitatively relate the closed system properties to the open one. The above analysis can be used to identify single spinless particle effects in experimental measurements of the open quantum dot limit. (paper)

  15. Investigation and Calculation of Magnetic Field in Tubular Linear Reluctance Motor Using FEM

    Directory of Open Access Journals (Sweden)

    MOSALLANEJAD, A.

    2010-11-01

    Full Text Available In this paper the magnetic flux density of tubular linear reluctance motor (TLRM in open type magnetic circuit is studied. Also, all magnetic flux density calculation methods in winding of tubular linear reluctance motor are described. The effect of structure parameters on magnetic flux density is also discussed. Electromagnetic finite-element analysis is used for simulation of magnetic field, and simulation results of the magnetic field analysis with DC voltage excitation are compared with results obtained from calculation methods. The comparison yields a good agreement.

  16. Magnetic and Electrical Properties of Leachate

    Directory of Open Access Journals (Sweden)

    Kartika Kirana

    2011-11-01

    Full Text Available Heavy metals content as well as magnetic and electrical properties of leachate from Sarimukti, West Java were studied in an attempt to seek correlation between heavy metals content and magnetic/electrical properties. Such correlation is expected to open the way for the use of magnetic/electrical properties as proxy indicators for the concentration of heavy metals in the leachate. The number of leachate samples studied is 21; 15 were taken spatially at depth of 1 m while the remaining 6 samples were taken vertically at a particular point. Measurement results showed that the heavy metals content in the leachate has a smaller concentration, except for Fe. The correlation between magnetic susceptibility and heavy metals content was found to be not so significant. The best correlation coefficient between magnetic susceptibility with heavy metals in leachate was found in Zn. Correlation between electrical conductivity and heavy metal is also not so significant, except for Zn and Cd. The use of magnetic properties as proxy indicator for heavy metals content in leachate is plausible provided that the magnetic susceptibility exceeds certain threshold value. Correlation between magnetic susceptibility, electrical conductivity and heavy metal content would be good if each quantity has a large value.

  17. Parallel inhomogeneity and the Alfven resonance. 1: Open field lines

    Science.gov (United States)

    Hansen, P. J.; Harrold, B. G.

    1994-01-01

    In light of a recent demonstration of the general nonexistence of a singularity at the Alfven resonance in cold, ideal, linearized magnetohydrodynamics, we examine the effect of a small density gradient parallel to uniform, open ambient magnetic field lines. To lowest order, energy deposition is quantitatively unaffected but occurs continuously over a thickened layer. This effect is illustrated in a numerical analysis of a plasma sheet boundary layer model with perfectly absorbing boundary conditions. Consequences of the results are discussed, both for the open field line approximation and for the ensuing closed field line analysis.

  18. Repetitive plasma opening switch for powerful high-voltage pulse generators

    International Nuclear Information System (INIS)

    Dolgachev, G.I.; Zakatov, L.P.; Nitishinskii, M.S.; Ushakov, A.G.

    1998-01-01

    Results are presented of experimental studies of plasma opening switches that serve to sharpen the pulses of inductive microsecond high-voltage pulse generators. It is demonstrated that repetitive plasma opening switches can be used to create super-powerful generators operating in a quasi-continuous regime. An erosion switching mechanism and the problem of magnetic insulation in repetitive switches are considered. Achieving super-high peak power in plasma switches makes it possible to develop new types of high-power generators of electron beams and X radiation. Possible implementations and the efficiency of these generators are discussed

  19. Hybrid magnets at Tohoku University

    International Nuclear Information System (INIS)

    Muto, Yoshio; Nakagawa, Yasuaki; Noto, Koshichi; Hoshi, Akira; Miura, Shigeto; Watanabe, Kazuo; Kido, Giyuu

    1984-01-01

    The High Field Laboratory for Superconducting Materials was established in April 1981 at Tohoku University in order to provide research facilities for the development of superconducting materials suitable for superconducting magnets for the plasma confinement in fusion reactors. Main facilities of this laboratory are three hybrid magnets up to 30 Tesla dc magnetic fields with inner bores from 32 to 52mm in diameter. The magnets consist of superconducting outer solenoids and water-cooled inner ones with a maximum steady power dissipation of 8 MW. The design and construction of these three hybrid magnets have finished in last three years, and two of them (HM-3;20T, 32 mm bore and HM-2; 23T, 52 mm bore) have already opened to scientists and engineers in the superconductivity and other fields. The rated field of the third hybrid magnet (HM-1) is 31 (or 29) Tesla in a bore of 32 (or 52) mm in diameter. By this hybrid system we have succeeded to produce 29.3 Tesla on April 21, 1984. Detailed descriptions are presented on the superconducting magnets, power supplies and cooling systems for them, water-cooled magnets, dc-high power source and water-cooled system for them, the monitoring and control system for the hybrid magnets including a super-minicomputer system, a hard-wired interlock system for the safety of human beings and machines, and so on. The fourth hybrid magnet system which aims at 35 Tesla as the next phase is also discussed. (author)

  20. Comparison of non-magnetic and magnetic beads in bead-based assays

    NARCIS (Netherlands)

    Hansenová Maňásková, S.; van Belkum, A.; Endtz, H.P.; Bikker, F.J.; Veerman, E.C.I.; van Wamel, W.J.B.

    2016-01-01

    Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens

  1. Proton beam transport experiments with pulsed high-field magnets at the Dresden laser acceleration source Draco

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Florian; Schramm, Ulrich [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universitaet Dresden, Dresden (Germany); Kraft, Stephan; Metzkes, Josefine; Schlenvoigt, Hans-Peter; Zeil, Karl [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany)

    2016-07-01

    Compact laser-driven ion accelerators are a potential alternative to large and expensive conventional accelerators. High-power short-pulse lasers, impinging on e.g. thin metal foils, enable multi-MeV ion acceleration on μm length and fs to ps time scale. The generated ion bunches (typically protons) show unique beam properties, like ultra-high pulse dose. Nevertheless, laser accelerators still require substantial development in reliable beam generation and transport. Recently developed pulsed magnets meet the demands of laser acceleration and open up new research opportunities: We present a pulsed solenoid for effective collection and focusing of laser-accelerated protons that acts as link between fundamental research and application. The solenoid is powered by a capacitor-based pulse generator and can reach a maximum magnetic field of 20 T. It was installed in the target chamber of the Draco laser at HZDR. The transported beam was detected by means of radiochromic film, scintillator and Thomson parabola spectrometer. We present the characterization of the solenoid with regard to future application in radiobiological irradiation studies. Furthermore, a detailed comparison to previous experiments with a similar magnet at the PHELIX laser at GSI, Darmstadt is provided.

  2. Detection of magnetic nanoparticles with magnetoencephalography

    Energy Technology Data Exchange (ETDEWEB)

    Jia Wenyan [Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Xu, Guizhi [Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Department of Biomedical Engineering, Hebei University of Technology, Tianjin, 300130 (China); Sclabassi, Robert J. [Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Zhu Jiangang [Department of Electrical and Computer Engineering, Carnegie Melon University, Pittsburgh, PA 15213 (United States); Bagic, Anto [Department of Neurology, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Sun Mingui [Department of Neurosurgery, University of Pittsburgh, Pittsburgh, PA 15260 (United States)], E-mail: mrsun@neuronet.pitt.edu

    2008-04-15

    Superconducting quantum interference devices (SQUIDs) have been widely utilized in biomedical applications due to their extremely high sensitivity to magnetic signals. The present study explores the feasibility of a new type of nanotechnology-based imaging method using standard clinical magnetoencephalographic (MEG) systems equipped with SQUID sensors. Previous studies have shown that biological targets labeled with non-toxic, magnetized nanoparticles can be imaged by measuring the magnetic field generated by these particles. In this work, we demonstrate that (1) the magnetic signals from certain nanoparticles can be detected without magnetization using standard clinical MEG, (2) for some types of nanoparticles, only bound particles produce detectable signals, and (3) the magnetic field of particles several hours after magnetization is significantly stronger than that of un-magnetized particles. These findings hold promise in facilitating the potential application of magnetic nanoparticles to in vivo tumor imaging. The minimum amount of nanoparticles that produce detectable signals is predicted by theoretical modeling and computer simulation.

  3. Magnetic tweezers optimized to exert high forces over extended distances from the magnet in multicellular systems

    Science.gov (United States)

    Selvaggi, L.; Pasakarnis, L.; Brunner, D.; Aegerter, C. M.

    2018-04-01

    Magnetic tweezers are mainly divided into two classes depending on the ability of applying torque or forces to the magnetic probe. We focused on the second category and designed a device composed by a single electromagnet equipped with a core having a special asymmetric profile to exert forces as large as 230 pN-2.8 μm Dynabeads at distances in excess of 100 μm from the magnetic tip. Compared to existing solutions our magnetic tweezers overcome important limitations, opening new experimental paths for the study of a wide range of materials in a variety of biophysical research settings. We discuss the benefits and drawbacks of different magnet core characteristics, which led us to design the current core profile. To demonstrate the usefulness of our magnetic tweezers, we determined the microrheological properties inside embryos of Drosophila melanogaster during the syncytial stage. Measurements in different locations along the dorsal-ventral axis of the embryos showed little variation, with a slight increase in cytoplasm viscosity at the periphery of the embryos. The mean cytoplasm viscosity we obtain by active force exertion inside the embryos is comparable to that determined passively using high-speed video microrheology.

  4. Improved reliability in skeletal age assessment using a pediatric hand MR scanner with a 0.3T permanent magnet.

    Science.gov (United States)

    Terada, Yasuhiko; Kono, Saki; Uchiumi, Tomomi; Kose, Katsumi; Miyagi, Ryo; Yamabe, Eiko; Fujinaga, Yasunari; Yoshioka, Hiroshi

    2014-01-01

    The purpose of this study was to improve the reliability and validity of skeletal age assessment using an open and compact pediatric hand magnetic resonance (MR) imaging scanner. We used such a scanner with 0.3-tesla permanent magnet to image the left hands of 88 healthy children (aged 3.4 to 15.7 years, mean 8.8 years), and 3 raters (2 orthopedic specialists and a radiologist) assessed skeletal age using those images. We measured the strength of agreement in ratings by values of weighted Cohen's κ and the proportion of cases excluded from rating because of motion artifact and inappropriate positioning. We compared the current results with those of a previous study in which 93 healthy children (aged 4.1 to 16.4 years, mean 9.7 years) were examined with an adult hand scanner. The κ values between raters exceeded 0.80, which indicates almost perfect agreement, and most were higher than those of the previous study. The proportion of cases excluded from rating because of motion artifact or inappropriate positioning was also reduced. The results indicate that use of the compact pediatric hand scanner improved the reliability and validity of skeletal age assessments.

  5. Tuning bacterial hydrodynamics with magnetic fields

    Science.gov (United States)

    Pierce, C. J.; Mumper, E.; Brown, E. E.; Brangham, J. T.; Lower, B. H.; Lower, S. K.; Yang, F. Y.; Sooryakumar, R.

    2017-06-01

    Magnetotactic bacteria are a group of motile prokaryotes that synthesize chains of lipid-bound, magnetic nanoparticles called magnetosomes. This study exploits their innate magnetism to investigate previously unexplored facets of bacterial hydrodynamics at surfaces. Through use of weak, uniform, external magnetic fields and local, micromagnetic surface patterns, the relative strength of hydrodynamic, magnetic, and flagellar force components is tuned through magnetic control of the bacteria's orientation. The resulting swimming behaviors provide a means to experimentally determine hydrodynamic parameters and offer a high degree of control over large numbers of living microscopic entities. The implications of this controlled motion for studies of bacterial motility near surfaces and for micro- and nanotechnology are discussed.

  6. Quantification of disc displacement in internal derangement of the temporomandibular joint using magnetic resonance imaging.

    Science.gov (United States)

    Arayasantiparb, Raweewan; Tsuchimochi, Makoto

    2010-02-01

    Many measures have been developed to determine the extent of disc displacement in internal derangements of the temporomandibular joint (TMJ) using magnetic resonance imaging. The purpose of this study was to develop a quantitative method of analyzing disc position and to evaluate the positions of the disc in internal derangements of the TMJ (group 1, with reduction; group 2, without reduction). Magnetic resonance images of 150 TMJs in 20 healthy volunteers and 55 patients with internal derangements were evaluated. The anatomical points of interest of the TMJ, including the anterior (DA) and posterior (DP) points of the disc, were marked on parasagittal magnetic resonance images of the TMJ disc taken in both the closed- and the open-mouth positions. All points were recorded using an x-y coordinate system, with reference to a referral line. In the closed-mouth position, the DP in patients in group 1 was situated in a more-anterior direction than the DP in volunteers. The DP in group 2 was located further anterior and inferior than the DP in group 1. However, the position of the DA did not differ between group 1 and group 2. In the open-mouth position, the DP was displaced anteroinferiorly to a greater extent in group 2 than in group 1 (one-way ANOVA, followed by Scheffe's test; P displaced TMJ discs revealed no significant difference. In conclusion, most of our results quantitatively support previously reported findings in imaging, surgical, and histopathological studies of TMJ internal derangement. We suggest that our measure of disc position of the TMJ would be useful to assess the status and response to treatment of internal derangements of the TMJ.

  7. Development of Correlations for Windage Power Losses Modeling in an Axial Flux Permanent Magnet Synchronous Machine with Geometrical Features of the Magnets

    Directory of Open Access Journals (Sweden)

    Alireza Rasekh

    2016-11-01

    Full Text Available In this paper, a set of correlations for the windage power losses in a 4 kW axial flux permanent magnet synchronous machine (AFPMSM is presented. In order to have an efficient machine, it is necessary to optimize the total electromagnetic and mechanical losses. Therefore, fast equations are needed to estimate the windage power losses of the machine. The geometry consists of an open rotor–stator with sixteen magnets at the periphery of the rotor with an annular opening in the entire disk. Air can flow in a channel being formed between the magnets and in a small gap region between the magnets and the stator surface. To construct the correlations, computational fluid dynamics (CFD simulations through the frozen rotor (FR method are performed at the practical ranges of the geometrical parameters, namely the gap size distance, the rotational speed of the rotor, the magnet thickness and the magnet angle. Thereafter, two categories of formulations are defined to make the windage losses dimensionless based on whether the losses are mainly due to the viscous forces or the pressure forces. At the end, the correlations can be achieved via curve fittings from the numerical data. The results reveal that the pressure forces are responsible for the windage losses for the side surfaces in the air-channel, whereas for the surfaces facing the stator surface in the gap, the viscous forces mainly contribute to the windage losses. Additionally, the results of the parametric study demonstrate that the overall windage losses in the machine escalate with an increase in either the rotational Reynolds number or the magnet thickness ratio. By contrast, the windage losses decrease once the magnet angle ratio enlarges. Moreover, it can be concluded that the proposed correlations are very useful tools in the design and optimizations of this type of electrical machine.

  8. Periodic Scarred States in Open Quantum Dots as Evidence of Quantum Darwinism

    Science.gov (United States)

    Burke, A. M.; Akis, R.; Day, T. E.; Speyer, Gil; Ferry, D. K.; Bennett, B. R.

    2010-04-01

    Scanning gate microscopy (SGM) is used to image scar structures in an open quantum dot, which is created in an InAs quantum well by electron-beam lithography and wet etching. The scanned images demonstrate periodicities in magnetic field that correlate to those found in the conductance fluctuations. Simulations have shown that these magnetic transform images bear a strong resemblance to actual scars found in the dot that replicate through the modes in direct agreement with quantum Darwinism.

  9. Determination of the neutron magnetic moment

    International Nuclear Information System (INIS)

    Greene, G.L.; Ramsey, N.F.; Mampe, W.; Pendlebury, J.M.; Smith, K.; Dress, W.B.; Miller, P.D.; Perrin, P.

    1981-01-01

    The neutron magnetic moment has been measured with an improvement of a factor of 100 over the previous best measurement. Using a magnetic resonance spectrometer of the separated oscillatory field type capable of determining a resonance signal for both neutrons and protons (in flowing H 2 O), we find μ/sub n//μ/sub p/ = 0.68497935(17) (0.25 ppM). The neutron magnetic moment can also be expressed without loss of accuracy in a variety of other units

  10. Study of open systems with molecules in isotropic liquids

    Science.gov (United States)

    Kondo, Yasushi; Matsuzaki, Masayuki

    2018-05-01

    We are interested in dynamics of a system in an environment, or an open system. Such phenomena as crossover from Markovian to non-Markovian relaxation and thermal equilibration are of our interest. Open systems have experimentally been studied with ultra cold atoms, ions in traps, optics, and cold electric circuits because well-isolated systems can be prepared here and thus the effects of environments can be controlled. We point out that some molecules solved in isotropic liquid are well isolated and thus they can also be employed for studying open systems in Nuclear Magnetic Resonance (NMR) experiments. First, we provide a short review on related phenomena of open systems that helps readers to understand our motivation. We, then, present two experiments as examples of our approach with molecules in isotropic liquids. Crossover from Markovian to non-Markovian relaxation was realized in one NMR experiment, while relaxation-like phenomena were observed in approximately isolated systems in the other.

  11. Probe branes thermalization in external electric and magnetic fields

    International Nuclear Information System (INIS)

    Ali-Akbari, M.; Ebrahim, H.; Rezaei, Z.

    2014-01-01

    We study thermalization on rotating probe branes in AdS 5 ×S 5 background in the presence of constant external electric and magnetic fields. In the AdS/CFT framework this corresponds to thermalization in the flavour sector in field theory. The horizon appears on the worldvolume of the probe brane due to its rotation in one of the sphere directions. For both electric and magnetic fields the behaviour of the temperature is independent of the probe brane dimension. We also study the open string metric and the fluctuations of the probe brane in such a set-up. We show that the temperatures obtained from open string metric and observed by the fluctuations are larger than the one calculated from the induced metric

  12. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Motte, Louise de la, E-mail: louise.de.la.motte@rh.regionh.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen (Denmark); Pedersen, Mads Møller, E-mail: phd@medit.dk [Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Thomsen, Carsten, E-mail: carsten.thomsen@rh.regionh.dk [Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Vogt, Katja, E-mail: Vogt@dadlnet.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Schroeder, Torben V., E-mail: Torben.Veith.schroeder@rh.regionh.dk [Department of Vascular Surgery, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark); Lonn, Lars, E-mail: lonn.lars@gmail.com [Department of Vascular Surgery and Department of Radiology, Rigshospitalet and University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen (Denmark)

    2013-10-01

    Background: Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of intraluminal thrombus specimens to the appearance on magnetic resonance imaging. Methods: Thirty-four patients undergoing open surgery for abdominal aortic aneurysm had a preoperative MRI obtained with a 1.5 T magnet. Qualitative categorization was performed (blinded and in consensus) and correlated to intraluminal thrombus to muscle signal-intensity ratios. Morphology of intraluminal thrombus specimens collected during surgery were compared to the magnetic resonance imaging categories and specimen weight was correlated to thrombus volume measured on preoperative computer tomography angiography. Results: Blinded MRI categorization resulted in agreement in 22 out of 34 intraluminal thrombi (Kappa value 0.3, p = 0.006). Medians (p = 0.004) and distribution (p = 0.002) of signal-intensity ratios varied significantly across the three MRI categories obtained by consensus. Heterogeneous and homogenous specimen appearance corresponded to similar appearances on MRI in 78% and 55% respectively, resulting in an overall Kappa = 0.4 (p = 0.04). Intraluminal thrombus volume and weight correlated well (r{sub s} 0.831, p < 0.001) with a mean difference of 60 g (95% CI 38–80 g), without proportional bias. Conclusion: Qualitative evaluation of intraluminal thrombus morphology based on MRI can be quantified by measuring signal-intensity ratios. Concurrently a fair agreement to blinded qualitative evaluation of thrombus specimens can be obtained. However, the evaluation is impaired by loss of a large proportion of thrombus during sampling.

  13. Categorization of aortic aneurysm thrombus morphology by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Motte, Louise de la; Pedersen, Mads Møller; Thomsen, Carsten; Vogt, Katja; Schroeder, Torben V.; Lonn, Lars

    2013-01-01

    Background: Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of intraluminal thrombus specimens to the appearance on magnetic resonance imaging. Methods: Thirty-four patients undergoing open surgery for abdominal aortic aneurysm had a preoperative MRI obtained with a 1.5 T magnet. Qualitative categorization was performed (blinded and in consensus) and correlated to intraluminal thrombus to muscle signal-intensity ratios. Morphology of intraluminal thrombus specimens collected during surgery were compared to the magnetic resonance imaging categories and specimen weight was correlated to thrombus volume measured on preoperative computer tomography angiography. Results: Blinded MRI categorization resulted in agreement in 22 out of 34 intraluminal thrombi (Kappa value 0.3, p = 0.006). Medians (p = 0.004) and distribution (p = 0.002) of signal-intensity ratios varied significantly across the three MRI categories obtained by consensus. Heterogeneous and homogenous specimen appearance corresponded to similar appearances on MRI in 78% and 55% respectively, resulting in an overall Kappa = 0.4 (p = 0.04). Intraluminal thrombus volume and weight correlated well (r s 0.831, p < 0.001) with a mean difference of 60 g (95% CI 38–80 g), without proportional bias. Conclusion: Qualitative evaluation of intraluminal thrombus morphology based on MRI can be quantified by measuring signal-intensity ratios. Concurrently a fair agreement to blinded qualitative evaluation of thrombus specimens can be obtained. However, the evaluation is impaired by loss of a large proportion of thrombus during sampling

  14. The Energy Balance of Plasma in a Coaxial Plasma Opening Switch

    International Nuclear Information System (INIS)

    Xu Xiang; Wang Younian

    2006-01-01

    The two-dimensional energy balance in a coaxial plasma opening switch (POS) is studied based on the single-fluid magnetohydrodynamic (MHD) equations coupled with the generalized Ohm's law. The energy transfers between the plasma and the magnetic field are considered during the penetration of the magnetic field as the Ohmic heating is included in the energy-balance equation. The focus is on the energy partition between the magnetic-field energy and the dissipated magnetic-field energy in a high-density POS with different rise-in-time electric currents at the generator boundary. The simulation code is tested in two cases: the constant-in-time current case and the linear rise-in-time current case. For the sinusoidally rise-in-time current similar to that of the experiments, it is shown that at the end of the conduction phase the dissipated magnetic-field energy is 36.5% of the input electromagnetic energy, which is consistent with the experimental results

  15. Traveling waves in a magnetized Taylor-Couette flow

    International Nuclear Information System (INIS)

    Liu Wei; Ji Hantao; Goodman, Jeremy

    2007-01-01

    We investigate numerically a traveling wave pattern observed in experimental magnetized Taylor-Couette flow at low magnetic Reynolds number. By accurately modeling viscous and magnetic boundaries in all directions, we reproduce the experimentally measured wave patterns and their amplitudes. Contrary to previous claims, the waves are shown to be transiently amplified disturbances launched by viscous boundary layers, rather than globally unstable magnetorotational modes

  16. Comparative analysis of the results of various physical therapy techniques in the treatment of patients with primary open-angle glaucoma with chronic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Lazarev М.S.

    2012-06-01

    Full Text Available

    Aim of the study: to evaluate the effectiveness of the techniques of dynamic simultaneous transcranial magnetic therapy and resonance, and electrical stimulation, transcranial magnetic therapy and dynamic laser stimulation, magnetic simpatokorrektsii in the treatment of patients with primary open-angle glaucoma with chronic cerebral ischemia. Techniques. We observed 184 patients diagnosed with primary open-angle glaucoma who received different physical therapy techniques. Results. Patients treated with transcranial magnetic therapy and electrical stimulation or laser stimulation, in addition to improving visual function and improve the bioelectrical activity of the visual cortex, more pronounced than in other groups also observed the activation of the intraocular blood fow. Application of magnetic simpatokorrektsii allows for improvement of basic functional, electrophysiological and hemodynamic performance by reducing the activity of the sympathetic nervous system and reduce the vasopressor effect. Conclusion. Transcranial magnetic therapy in combination with electrical stimulation or laser stimulation is effective in the treatment of patients with POAG. In patients with primary open-angle glaucoma with chronic cerebral ischemia technique of magnetic sim-patokorrektsii compared with traditional methods of vasoactive therapy is more effective, which is manifested not only increase the visual functions, but also a decrease in cognitive impairment.

  17. A multi-purpose open-source triggering platform for magnetic resonance

    Science.gov (United States)

    Ruytenberg, T.; Webb, A. G.; Beenakker, J. W. M.

    2014-10-01

    Many MR scans need to be synchronised with external events such as the cardiac or respiratory cycles. For common physiological functions commercial trigger equipment exists, but for more experimental inputs these are not available. This paper describes the design of a multi-purpose open-source trigger platform for MR systems. The heart of the system is an open-source Arduino Due microcontroller. This microcontroller samples an analogue input and digitally processes these data to determine the trigger. The output of the microcontroller is programmed to mimic a physiological signal which is fed into the electrocardiogram (ECG) or pulse oximeter port of MR scanner. The microcontroller is connected to a Bluetooth dongle that allows wireless monitoring and control outside the scanner room. This device can be programmed to generate a trigger based on various types of input. As one example, this paper describes how it can be used as an acoustic cardiac triggering unit. For this, a plastic stethoscope is connected to a microphone which is used as an input for the system. This test setup was used to acquire retrospectively-triggered cardiac scans in ten volunteers. Analysis showed that this platform produces a reliable trigger (>99% triggers are correct) with a small average 8 ms variation between the exact trigger points.

  18. A dynamic macromodel for distributed parameter magnetic microactuators

    International Nuclear Information System (INIS)

    Fang Yuming; Huang Qingan; Li Weihua

    2008-01-01

    This paper presents a reduced-order model to describe the mechanical behaviour of microbeam-based magnetic devices. The integration for magnetic force is calculated by dividing the microbeam into several segments, and the nonlinear equation set has been developed based on the magnetic circuit principle. In comparison with previous models, the present macromodel accounts for both the micro-magnetic-core reluctance and the coupling between the beam deflection and magnetic force. This macromodel is validated by comparing with the experimental results available in some papers and finite-element solutions

  19. Planetary nebulae and the interstellar magnetic field

    International Nuclear Information System (INIS)

    Heiligman, G.M.

    1980-01-01

    Previous workers have found a statistical correlation between the projected directions of the interstellar magnetic field and the major axes of planetary nebulae. This result has been examined theoretically using a numerical hydromagnetic model of a cold plasma nebula expanding into a uniform vacuum magnetic field, with nebular gas accreting on the surface. It is found that magnetic pressure alone is probably not sufficient to shape most planetary nebulae to the observed degree. Phenomena are discussed which could amplify simple magnetic pressure, alter nebular morphology and account for the observed correlation. (author)

  20. Chemical Detection using Electrically Open Circuits having no Electrical Connections

    Science.gov (United States)

    Woodward, Stanley E.; Olgesby, Donald M.; Taylor, Bryant D.; Shams, Qamar A.

    2008-01-01

    This paper presents investigations to date on chemical detection using a recently developed method for designing, powering and interrogating sensors as electrically open circuits having no electrical connections. In lieu of having each sensor from a closed circuit with multiple electrically connected components, an electrically conductive geometric pattern that is powered using oscillating magnetic fields and capable of storing an electric field and a magnetic field without the need of a closed circuit or electrical connections is used. When electrically active, the patterns respond with their own magnetic field whose frequency, amplitude and bandwidth can be correlated with the magnitude of the physical quantities being measured. Preliminary experimental results of using two different detection approaches will be presented. In one method, a thin film of a reactant is deposited on the surface of the open-circuit sensor. Exposure to a specific targeted reactant shifts the resonant frequency of the sensor. In the second method, a coating of conductive material is placed on a thin non-conductive plastic sheet that is placed over the surface of the sensor. There is no physical contact between the sensor and the electrically conductive material. When the conductive material is exposed to a targeted reactant, a chemical reaction occurs that renders the material non-conductive. The change in the material s electrical resistance within the magnetic field of the sensor alters the sensor s response bandwidth and amplitude, allowing detection of the reaction without having the reactants in physical contact with the sensor.

  1. Open questions in the magnetic behaviour of high-temperature superconductors

    International Nuclear Information System (INIS)

    Cohen, L.F.; Jensen, Henrik Jeldtoft

    1997-01-01

    A principally experimental review of vortex behaviour in high-temperature superconductors is presented. The reader is first introduced to the basic concepts needed to understand the magnetic properties of type II superconductors. The concepts of vortex melting, the vortex glass, vortex creep, etc are also discussed briefly. The bulk part of the review relates the theoretical predictions proposed for the vortex system in high temperature superconductors to experimental findings. The review ends with an attempt to direct the reader to those areas which still require further clarification. (author)

  2. Numerical study of compressible magnetoconvection with an open transitional boundary

    International Nuclear Information System (INIS)

    Hanami, H.; Tajima, T.

    1990-08-01

    We study by computer simulation nonlinear evolution of magnetoconvection in a system with a dynamical open boundary between the convection region and corona of the sun. We study a model in which the fluid is subject to the vertical gravitation, magnetohydrodynamics (MHD), and high stratification, through an MHD code with the MacCormack-Donner cell hybrid scheme in order to well represent convective phenomena. Initially the vertical fluid flux penetrates from the convectively unstable zone at the bottom into the upper diffuse atmosphere. As the instability develops, the magnetic fields are twisted by the convection motion and the folding magnetic fields is observed. When the magnetic pressure is comparable to the thermal pressure in the upper layer of convective zone, strong flux expulsion from the convective cell interior toward the cell boundary appears. Under appropriate conditions our simulation exhibits no shock formation incurred by the fluid convected to the photosphere, in contrast to earlier works with box boundaries. The magnetic field patterns observed are those of concentrated magnetic flux tubes, accumulation of dynamo flux near the bottom boundary, pinched flux near the downdraft region, and the surface movement of magnetic flux toward the downdraft region. Many of these computationally observed features are reminiscent of solar observations of the fluid and magnetic structures of their motions

  3. Design of a 2 Tesla transmission line magnet for the VLHC

    CERN Document Server

    Foster, G W; Novitski, I

    2000-01-01

    A prototype of the transmission line magnet for the Very Large Hadron Collider is being designed at Fermilab. This is a single-turn warm iron superconducting magnet in a "Double-C" configuration. Iron poles form a high quality alternating-gradient magnet field in two 20 mm height beam gaps. Simple magnet construction and manufacturing processes and a room temperature iron yoke give a significant reduction in magnet cost. Open beam gaps simplify magnetic measurements and vacuum chamber installation. The magnet mechanical stability was investigated for several mechanical models. A high field quality over the whole range (0.1 T-2.0 T) of field variation was calculated using correcting holes in the iron poles. The magnet optimization was carried out by POISSON, OPERA 2D and ANSYS codes. The results of magnet design and model tests are presented. (6 refs).

  4. Magnetic fields in cosmology

    International Nuclear Information System (INIS)

    Madsen, M.S.

    1989-01-01

    The possible role of a large-scale relic magnetic field in the history of the Universe is considered. The perturbation of the cosmic microwave back-ground radiation on large angular scales due to a homogeneous magnetic field is estimated in a simple relativistic model. This allows corresponding limits to be placed on the magnitude of any such large-scale relic magnetic field at the present time. These limits are essentially the strongest which can be set on the largest scales. A corresponding bound is obtained by use of the requirement that the field should not spoil the predictions of primordial nucleosynthesis. It is noted that the existence of large-scale cosmic magnetic fields would circumvent the limits previously set - also on the basis of nucleosynthesis considerations - on the large-scale anisotropy now present in the Universe. (author)

  5. Holographic Chiral Magnetic Spiral

    International Nuclear Information System (INIS)

    Kim, Keun-Young; Sahoo, Bindusar; Yee, Ho-Ung

    2010-06-01

    We study the ground state of baryonic/axial matter at zero temperature chiral-symmetry broken phase under a large magnetic field, in the framework of holographic QCD by Sakai-Sugimoto. Our study is motivated by a recent proposal of chiral magnetic spiral phase that has been argued to be favored against previously studied phase of homogeneous distribution of axial/baryonic currents in terms of meson super-currents dictated by triangle anomalies in QCD. Our results provide an existence proof of chiral magnetic spiral in strong coupling regime via holography, at least for large axial chemical potentials, whereas we don't find the phenomenon in the case of purely baryonic chemical potential. (author)

  6. The electromagnetic multipole moments of the charged open-flavor {Z}_{\\bar{c}q} states

    Science.gov (United States)

    Azizi, K.; Özdem, U.

    2018-05-01

    The electromagnetic multipole moments of the open-flavor {Z}\\bar{cq} states are investigated by assuming a diquark–antidiquark picture for their internal structure and quantum numbers {J}{PC}={1}+- for their spin-parity. In particular, their magnetic and quadrupole moments are extracted in the framework of light-cone QCD sum rule by the help of the photon distribution amplitudes. The electromagnetic multipole moments of the open-flavor {Z}\\bar{cq} states are important dynamical observables, which encode valuable information on their underlying structure. The results obtained for the magnetic moments of different structures are considerably large and can be measured in future experiments. We obtain very small values for the quadrupole moments of {Z}\\bar{cq} states indicating a nonspherical charge distribution.

  7. Magnetic behavior of nanocrystalline CoFe2O4

    International Nuclear Information System (INIS)

    Zhang Kai; Holloway, T.; Pradhan, A.K.

    2011-01-01

    Magnetic nanoparticles of CoFe 2 O 4 have been synthesized under an applied magnetic field through a co-precipitation method followed by thermal treatments at different temperatures, producing nanoparticles of varying size. The magnetic behavior of these nanoparticles was investigated. As-grown nanoparticles demonstrate superparamagnetism above the blocking temperature, which is dependent on the particle size. One of the nanoparticles demonstrated a constricted magnetic hysteresis loop with no or small coercivity and remanence at low magnetic field. However, the loop opens up at high magnetic field. This magnetic behavior is attributed to the preferred Co ions and vacancies arrangements when the CoFe 2 O 4 nanoparticles were synthesized under an applied magnetic field. Furthermore, this magnetic property is strongly dependent on the high temperature heat treatments that produce Co ions and vacancies disorder. - Research highlights: → CoFe 2 O 4 nanoparticles were synthesized by co-precipitation route in a magnetic field. → Smaller nanoparticles present superparamagnetic property above their block temperature. → These nanoparticles show interesting magnetic behavior in the blocking state. → Magnetic behavior is strongly dependent on the annealing temperature.

  8. Demonstration of Magnetic Dipole Resonances of Dielectric Nanospheres in the Visible Region

    DEFF Research Database (Denmark)

    Evlyukhin, A. B.; Novikov, S. M.; Zywietz, U.

    2012-01-01

    Strong resonant light scattering by individual spherical Si nanoparticles is experimentally demonstrated, revealing pronounced resonances associated with the excitation of magnetic and electric modes in these nanoparticles. It is shown that the low-frequency resonance corresponds to the magnetic...... dipole excitation. Due to high permittivity, the magnetic dipole resonance is observed in the visible spectral range for Si nanoparticles with diameters of similar to 200 nm, thereby opening a way to the realization of isotropic optical metamaterials with strong magnetic responses in the visible region....

  9. INTERSTELLAR MAGNETIC FIELD SURROUNDING THE HELIOPAUSE

    International Nuclear Information System (INIS)

    Whang, Y. C.

    2010-01-01

    This paper presents a three-dimensional analytical solution, in the limit of very low plasma β-ratio, for the distortion of the interstellar magnetic field surrounding the heliopause. The solution is obtained using a line dipole method that is the integration of point dipole along a semi-infinite line; it represents the magnetic field caused by the presence of the heliopause. The solution allows the variation of the undisturbed magnetic field at any inclination angle. The heliosphere is considered as having blunt-nosed geometry on the upwind side and it asymptotically approaches a cylindrical geometry having an open exit for the continuous outflow of the solar wind on the downwind side. The heliopause is treated as a magnetohydrodynamic tangential discontinuity; the interstellar magnetic field lines at the boundary are tangential to the heliopause. The interstellar magnetic field is substantially distorted due to the presence of the heliopause. The solution shows the draping of the field lines around the heliopause. The magnetic field strength varies substantially near the surface of the heliopause. The effect on the magnetic field due to the presence of the heliopause penetrates very deep into the interstellar space; the depth of penetration is of the same order of magnitude as the scale length of the heliosphere.

  10. Differential effects of magnetic field exposure from domestic power supply on loco motor and exploratory behavior of an adult rat

    International Nuclear Information System (INIS)

    Anandavadivel, A.; Caleo, M.

    2011-01-01

    In the present study, we have examined the low intense magnetic field exposed on adult rats to understand effect of several behavioral parameters. The rats are tested in the open field and spontaneous alternation task after either a single or chronic exposure to the magnetic field. We found that magnetic field exposure had no effect on locomotor behavior in the adult. However, the exploratory behavior of adult rats in the open field was significantly affected. Indeed, we found a consistent increase in behavior performance viz. exploration time and number of exploration events in rats exposed to magnetic field. Our results demonstrate behavioral changes after magnetic field exposure in adult subjects. This also suggests possible deleterious effects of magnetic field exposure in the brain. (author)

  11. Nanopatterning reconfigurable magnetic landscapes via thermally assisted scanning probe lithography

    Science.gov (United States)

    Albisetti, E.; Petti, D.; Pancaldi, M.; Madami, M.; Tacchi, S.; Curtis, J.; King, W. P.; Papp, A.; Csaba, G.; Porod, W.; Vavassori, P.; Riedo, E.; Bertacco, R.

    2016-06-01

    The search for novel tools to control magnetism at the nanoscale is crucial for the development of new paradigms in optics, electronics and spintronics. So far, the fabrication of magnetic nanostructures has been achieved mainly through irreversible structural or chemical modifications. Here, we propose a new concept for creating reconfigurable magnetic nanopatterns by crafting, at the nanoscale, the magnetic anisotropy landscape of a ferromagnetic layer exchange-coupled to an antiferromagnetic layer. By performing localized field cooling with the hot tip of a scanning probe microscope, magnetic structures, with arbitrarily oriented magnetization and tunable unidirectional anisotropy, are reversibly patterned without modifying the film chemistry and topography. This opens unforeseen possibilities for the development of novel metamaterials with finely tuned magnetic properties, such as reconfigurable magneto-plasmonic and magnonic crystals. In this context, we experimentally demonstrate spatially controlled spin wave excitation and propagation in magnetic structures patterned with the proposed method.

  12. Sequential magnetic switching in Fe/MgO(001) superlattices

    Science.gov (United States)

    Magnus, F.; Warnatz, T.; Palsson, G. K.; Devishvili, A.; Ukleev, V.; Palisaitis, J.; Persson, P. O. Å.; Hjörvarsson, B.

    2018-05-01

    Polarized neutron reflectometry is used to determine the sequence of magnetic switching in interlayer exchange coupled Fe/MgO(001) superlattices in an applied magnetic field. For 19.6 Å thick MgO layers we obtain a 90∘ periodic magnetic alignment between adjacent Fe layers at remanence. In an increasing applied field the top layer switches first followed by its second-nearest neighbor. For 16.4 Å MgO layers, a 180∘ periodic alignment is obtained at remanence and with increasing applied field the layer switching starts from the two outermost layers and proceeds inwards. This sequential tuneable switching opens up the possibility of designing three-dimensional magnetic structures with a predefined discrete switching sequence.

  13. Fingerprints of transverse and longitudinal coupling between induced open quantum dots in the longitudinal magnetoconductance through antidot lattices

    Science.gov (United States)

    Ujevic, Sebastian; Mendoza, Michel

    2010-07-01

    We propose numerical simulations of longitudinal magnetoconductance through a finite antidot lattice located inside an open quantum dot with a magnetic field applied perpendicular to the plane. The system is connected to reservoirs using quantum point contacts. We discuss the relationship between the longitudinal magnetoconductance and the generation of transversal couplings between the induced open quantum dots in the system. The system presents longitudinal magnetoconductance maps with crossovers (between transversal bands) and closings (longitudinal decoupling) of fundamental quantum states related to the open quantum dots induced by the antidot lattice. A relationship is observed between the distribution of antidots and the formed conductance bands, allowing a systematic follow up of the bands as a function of the applied magnetic field and quantum point-contact width. We observed a high conductance intensity [between n and (n+1) quantum of conductance, n=1,2,… ] in the regions of crossover and closing of states. This suggests transversal couplings between the induced open quantum dots of the system that can be modulated by varying both the antidots potential and the quantum point-contact width. A new continuous channel (not expected) is induced by the variation in the contact width and generate Fano resonances in the conductance. These resonances can be manipulated by the applied magnetic field.

  14. Method for Transformation of Weakly Magnetic Minerals (Hematite, Goethite into Strongly Magnetic Mineral (Magnetite to Improve the Efficiency of Technologies for Oxidized Iron Ores Benefication

    Directory of Open Access Journals (Sweden)

    Ponomarenko, O.

    2015-03-01

    Full Text Available A new method for relatively simple transformation of weakly magnetic minerals (goethite (α-FeOOH and hematite (α-Fe2O3 into strongly magnetic mineral (magnetite (Fe3O4 was developed. It was shown, that transformation of structure and magnetic characteristics of go ethite and hematite are realized in the presence of starch at relatively low temperatures (in the range of 300—600 °С. Obtained results open up new possibilities for development of effective technologies for oxidized iron ore beneficiation.

  15. Deflection of weakly magnetic materials by superconducting OGMS

    International Nuclear Information System (INIS)

    Boehm, J.; Gerber, R.; Fletcher, D.; Parker, M.R.

    1988-01-01

    Applications of a superconducting Open Gradient Magnetic Separator to fractional separation in air of weakly magnetic materials are presented. The dependence of particle deflection of these materials on the magnetic field strength, release location, magnetic susceptibility, particle density and other properties is investigated. The aim is to maximise the deflection of the magnetically stronger component of the feed to facilitate its separation from the particle stream round the magnet. Materials (e.g. CuSO/sub 4/, MnO/sub 2/) with chi/rho- ratios of the order of 7 x 10/sup -8/ m/sup 3//kg have been deflected. The applicability of dry magnetic separation has thus been considerably extended since up to now the separation of such materials has been restricted to High Gradient Magnetic Separation. The dependence of the separation efficiency upon the method of feeding and the influence of the residence time are studied in order to establish the optimum parameters for the recovery of the desired fraction. The experimental results are compared with predictions of a theory that is based upon novel approximative calculations of magnetic fields in which the use of elliptic integrals is avoided

  16. The concept of openness behind c and x-MOOCs (Massive Open Online Courses

    Directory of Open Access Journals (Sweden)

    Osvaldo Rodriguez

    2013-01-01

    Full Text Available The last five years have witnessed a hype about MOOCs (Massive Open Online Courses presaging a revolution in higher education. Although all MOOCs have in common their scale and free access, they have already bifurcated in two very distinct types of courses when compared in terms of their underpinning theory, format and structure, known as c-MOOCs and x-MOOCs. The concept of openness behind each of the formats is also very different. Previous studies have shown that c-and x-MOOCs share some common features but that they clearly differ on the learning theory and pedagogical model on which they stand. In this paper we extend earlier findings and concentrate on the concept of “openness” behind each format showing important differences.

  17. Counterstreaming solar wind halo electron events on open field lines?

    Science.gov (United States)

    Gosling, J. T.; Mccomas, D. J.; Phillips, J. L.

    1992-01-01

    Counterstreaming solar wind halo electron events have been identified as a common 1 AU signature of coronal mass ejection events, and have generally been interpreted as indicative of closed magnetic field topologies, i.e., magnetic loops or flux ropes rooted at both ends in the Sun, or detached plasmoids. In this paper we examine the possibility that these events may instead occur preferentially on open field lines, and that counterstreaming results from reflection or injection behind interplanetary shocks or from mirroring from regions of compressed magnetic field farther out in the heliosphere. We conclude that neither of these suggested sources of counterstreaming electron beams is viable and that the best interpretation of observed counterstreaming electron events in the solar wind remains that of passage of closed field structures.

  18. The Quest for Nanoscale Magnets: The example of [Mn12] Single Molecule Magnets.

    Science.gov (United States)

    Rogez, Guillaume; Donnio, Bertrand; Terazzi, Emmanuel; Gallani, Jean-Louis; Kappler, Jean-Paul; Bucher, Jean-Pierre; Drillon, Marc

    2009-11-20

    Recent advances on the organization and characterization of [Mn12] single molecule magnets (SMMs) on a surface or in 3D are reviewed. By using nonconventional techniques such as X-ray magnetic circular dichroism (XMCD) and scanning tunneling microscopy (STM), it is shown that [Mn12]-based SMMs deposited on a surface lose their SMM behavior, even though the molecules seem to be structurally undamaged. A new approach is reported to get high-density information-storage devices, based on the 3D assembling of SMMs in a liquid crystalline phase. The 3D nanostructure exhibits the anisotropic character of the SMMs, thus opening the way to address micrometric volumes by two photon absorption using the pump-probe technique. We present recent developments such as µ-SQUID, magneto-optical Kerr effect (MOKE), or magneto-optical circular dichroism (MOCD), which enable the characterization of SMM nanostructures with exceptional sensitivity. Further, the spin-polarized version of the STM under ultrahigh vacuum is shown to be the key tool for addressing not only single molecule magnets, but also magnetic nano-objects. Copyright © 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner.

    Science.gov (United States)

    Miki, Kohei; Masamune, Ken

    2015-10-01

    Low-field open magnetic resonance imaging (MRI) is frequently used for performing image-guided neurosurgical procedures. Intraoperative magnetic resonance (MR) images are useful for tracking brain shifts and verifying residual tumors. However, it is difficult to precisely determine the boundary of the brain tumors and normal brain tissues because the MR image resolution is low, especially when using a low-field open MRI scanner. To overcome this problem, a high-resolution MR image acquisition system was developed and tested. An MR-compatible manipulator with pneumatic actuators containing an MR signal receiver with a small radiofrequency (RF) coil was developed. The manipulator had five degrees of freedom for position and orientation control of the RF coil. An 8-mm planar RF coil with resistance and inductance of 2.04 [Formula: see text] and 1.00 [Formula: see text] was attached to the MR signal receiver at the distal end of the probe. MR images of phantom test devices were acquired using the MR signal receiver and normal head coil for signal-to-noise ratio (SNR) testing. The SNR of MR images acquired using the MR signal receiver was 8.0 times greater than that of MR images acquired using the normal head coil. The RF coil was moved by the manipulator, and local MR images of a phantom with a 2-mm grid were acquired using the MR signal receiver. A wide field-of-view MR image was generated from a montage of local MR images. A small field-of-view RF system with a pneumatic manipulator was integrated in a low-field MRI scanner to allow acquisition of both wide field-of-view and high-resolution MR images. This system is promising for image-guided neurosurgery as it may allow brain tumors to be observed more clearly and removed precisely.

  20. Mercury's Lithospheric Magnetization

    Science.gov (United States)

    Johnson, C.; Phillips, R. J.; Philpott, L. C.; Al Asad, M.; Plattner, A.; Mast, S.; Kinczyk, M. J.; Prockter, L. M.

    2017-12-01

    Magnetic field data obtained by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft have been used to demonstrate the presence of lithospheric magnetization on Mercury. Larger amplitude fields resulting from the core dynamo and the strongly time-varying magnetospheric current systems are first estimated and subtracted from the magnetic field data to isolate lithospheric signals with wavelengths less than 500 km. These signals (hereafter referred to as data) are only observed at spacecraft altitudes less than 120 km, and are typically a few to 10 nT in amplitude. We present and compare equivalent source dipole magnetization models for latitudes 35°N to 75°N obtained from two distinct approaches to constrain the distribution and origin of lithospheric magnetization. First, models that fit either the data or the surface field predicted from a regional spherical harmonic representation of the data (see Plattner & Johnson abstract) and that minimize the root mean square (RMS) value of the magnetization are derived. Second, models in which the spatial distribution of magnetization required to fit the data is minimized are derived using the approach of Parker (1991). As seen previously, the largest amplitudes of lithospheric magnetization are concentrated around the Caloris basin. With this exception, across the northern hemisphere there are no overall correlations of magnetization with surface geology, although higher magnetizations are found in regions with darker surfaces. Similarly, there is no systematic correlation of magnetization signatures with crater materials, although there are specific instances of craters with interiors or ejecta that have magnetizations distinct from the surrounding region. For the latter case, we observe no correlation of the occurrence of these signatures with crater degradation state (a proxy for age). At the lowest spacecraft altitudes (source depths less than O(10 km) are unlikely in most regions

  1. Recent analytical applications of magnetic nanoparticles

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-07-01

    Full Text Available Analytical chemistry has experienced, as well as other areas of science, a big change due to the needs and opportunities provided by analytical nanoscience and nanotechnology. Now, nanotechnology is increasingly proving to be a powerful ally of analytical chemistry to achieve its objectives, and to simplify analytical processes. Moreover, the information needs arising from the growing nanotechnological activity are opening an exciting new field of action for analytical chemists. Magnetic nanoparticles have been used in various fields owing to their unique properties including large specific surface area and simple separation with magnetic fields. For Analytical applications, they have been used mainly for sample preparation techniques (magnetic solid phase extraction with different advanced functional groups (layered double hydroxide, β-cyclodextrin, carbon nanotube, graphen, polymer, octadecylsilane and automation of it, microextraction techniques enantioseparation and chemosensors. This review summarizes the basic principles and achievements of magnetic nanoparticles in sample preparation techniques, enantioseparation and chemosensors. Also, some selected articles recently published (2010-2016 have been reviewed and discussed.

  2. Tuning the magnetism of ferrite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Viñas, S. Liébana [Faculty of Physics and CENIDE, University Duisburg-Essen, Duisburg 47048 (Germany); Departamento de Física Aplicada, Universidade de Vigo, Vigo 36310 (Spain); Simeonidis, K. [Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Li, Z.-A.; Ma, Z. [Faculty of Physics and CENIDE, University Duisburg-Essen, Duisburg 47048 (Germany); Myrovali, E.; Makridis, A.; Sakellari, D. [Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Angelakeris, M., E-mail: agelaker@auth.gr [Department of Physics, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Wiedwald, U.; Spasova, M. [Faculty of Physics and CENIDE, University Duisburg-Essen, Duisburg 47048 (Germany); Farle, M., E-mail: michael.farle@uni-due.de [Faculty of Physics and CENIDE, University Duisburg-Essen, Duisburg 47048 (Germany)

    2016-10-01

    The importance of magnetic interactions within an individual nanoparticle or between adjacent ones is crucial not only for the macroscopic collective magnetic behavior but for the AC magnetic heating efficiency as well. On this concept, single-(MFe{sub 2}O{sub 4} where M=Fe, Co, Mn) and core–shell ferrite nanoparticles consisting of a magnetically softer (MnFe{sub 2}O{sub 4}) or magnetically harder (CoFe{sub 2}O{sub 4}) core and a magnetite (Fe{sub 3}O{sub 4}) shell with an overall size in the 10 nm range were synthesized and studied for their magnetic particle hyperthermia efficiency. Magnetic measurements indicate that the coating of the hard magnetic phase (CoFe{sub 2}O{sub 4}) by Fe{sub 3}O{sub 4} provides a significant enhancement of hysteresis losses over the corresponding single-phase counterpart response, and thus results in a multiplication of the magnetic hyperthermia efficiency opening a novel pathway for high-performance, magnetic hyperthermia agents. At the same time, the existence of a biocompatible Fe{sub 3}O{sub 4} outer shell, toxicologically renders these systems similar to iron-oxide ones with significantly milder side-effects. - Highlights: • Magnetic hyperthermia is studied for 10 nm single and core/shell ferrite nanoparticles. • Maximum heating rate is observed for Fe{sub 3}O{sub 4}-coated CoFe{sub 2}O{sub 4} nanoparticles. • The increase is attributed to the interaction of phases with different anisotropy. • The presence of biocompatible Fe{sub 3}O{sub 4} shell potentially minimizes toxic side-effects.

  3. Laparoscopic vs open gastrectomy. A retrospective review.

    Science.gov (United States)

    Reyes, C D; Weber, K J; Gagner, M; Divino, C M

    2001-09-01

    The totally laparoscopic approach to partial gastrectomy had not been compared previously with results of the open technique. This study compares the results of a series of laparoscopic cases with matched open cases. A retrospective case-matched study was performed in 36 patients (18 laparoscopic surgeries, 18 open surgeries). Each laparoscopic case was matched for patient age and indication for surgery. The intraoperative and postoperative details of the two groups were compared. Laparoscopic surgery resulted in less blood loss, although operative time was increased. Nasogastric tubes were less likely to be used after laparoscopic surgery, and patients in the laparoscopic group had an earlier return to normal bowel function than those in the open group. Length of hospital stay was 2 days shorter in the laparoscopic group. The totally laparoscopic approach to partial gastrectomy is an excellent alternative to the more traditional open approach. It results in a more rapid return of intestinal function and a shorter hospital stay.

  4. Health-related quality of life after laparoscopic and open surgery for rectal cancer in a randomized trial

    DEFF Research Database (Denmark)

    Andersson, J; Angenete, E; Gellerstedt, M

    2013-01-01

    Previous studies comparing laparoscopic and open surgical techniques have reported improved health-related quality of life (HRQL). This analysis compared HRQL 12¿months after laparoscopic versus open surgery for rectal cancer in a subset of a randomized trial.......Previous studies comparing laparoscopic and open surgical techniques have reported improved health-related quality of life (HRQL). This analysis compared HRQL 12¿months after laparoscopic versus open surgery for rectal cancer in a subset of a randomized trial....

  5. Electron and ion magnetohydrodynamic effects in plasma opening switches

    International Nuclear Information System (INIS)

    Grossmann, J.M.; DeVore, C.R.; Ottinger, P.F.

    1993-01-01

    Preliminary results are presented of a numerical code designed to investigate electron and ion magnetohydrodynamic effects in plasma erosion opening switches. The present model is one-dimensional and resolves effects such as the JxB deformation of the plasma, and the penetration of magnetic field either by anomalous resistivity or electron magnetohydrodynamics (Hall effect). Comparisons with exact analytic results and experiment are made

  6. Conceptual design of a quadrupole magnet for eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Witte, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    eRHIC is a proposed upgrade to the existing Relativistic Heavy Ion Collider (RHIC) hadron facility at Brookhaven National Laboratory, which would allow collisions of up to 21 GeV polarized electrons with a variety of species from the existing RHIC accelerator. eRHIC employs an Energy Recovery Linac (ERL) and an FFAG lattice for the arcs. The arcs require open-midplane quadrupole magnets of up to 30 T/m gradient of good field quality. In this paper we explore initial quadrupole magnet design concepts based on permanent magnetic material which allow to modify the gradient during operation.

  7. A multi-purpose open-source triggering platform for magnetic resonance.

    Science.gov (United States)

    Ruytenberg, T; Webb, A G; Beenakker, J W M

    2014-10-01

    Many MR scans need to be synchronised with external events such as the cardiac or respiratory cycles. For common physiological functions commercial trigger equipment exists, but for more experimental inputs these are not available. This paper describes the design of a multi-purpose open-source trigger platform for MR systems. The heart of the system is an open-source Arduino Due microcontroller. This microcontroller samples an analogue input and digitally processes these data to determine the trigger. The output of the microcontroller is programmed to mimic a physiological signal which is fed into the electrocardiogram (ECG) or pulse oximeter port of MR scanner. The microcontroller is connected to a Bluetooth dongle that allows wireless monitoring and control outside the scanner room. This device can be programmed to generate a trigger based on various types of input. As one example, this paper describes how it can be used as an acoustic cardiac triggering unit. For this, a plastic stethoscope is connected to a microphone which is used as an input for the system. This test setup was used to acquire retrospectively-triggered cardiac scans in ten volunteers. Analysis showed that this platform produces a reliable trigger (>99% triggers are correct) with a small average 8 ms variation between the exact trigger points. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Two phase cooling for superconducting magnets

    International Nuclear Information System (INIS)

    Eberhard, P.H.; Gibson, G.A.; Green, M.A.; Ross, R.R.; Smits, R.G.

    1986-01-01

    Comments on the use of two phase helium in a closed circuit tubular cooling system and some results obtained with the TPC superconducting magnet are given. Theoretical arguments and experimental evidence are given against a previously suggested method to determine helium two phase flow regimes. Two methods to reduce pressure in the magnet cooling tubes during quenches are discussed; 1) lowering the density of helium in the magnet cooling tubes and 2) proper location of pressure relief valves. Some techniques used to protect the refrigerator from too much cold return gas are also mentioned

  9. Further validation of liquid metal MHD code for unstructured grid based on OpenFOAM

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Jingchao; Chen, Hongli, E-mail: hlchen1@ustc.edu.cn; He, Qingyun; Ye, Minyou

    2015-11-15

    Highlights: • Specific correction scheme has been adopted to revise the calculating result for non-orthogonal meshes. • The developed MHD code based on OpenFOAM platform has been validated by benchmark cases under uniform and non-uniform magnetic field in round and rectangular ducts. • ALEX experimental results have been used to validate the MHD code based on OpenFOAM. - Abstract: In fusion liquid metal blankets, complex geometries involving contractions, expansions, bends, manifolds are very common. The characteristics of liquid metal flow in these geometries are significant. In order to extend the magnetohydrodynamic (MHD) solver developed on OpenFOAM platform to be applied in the complex geometry, the MHD solver based on unstructured meshes has been implemented. The adoption of non-orthogonal correction techniques in the solver makes it possible to process the non-orthogonal meshes in complex geometries. The present paper focused on the validation of the code under critical conditions. An analytical solution benchmark case and two experimental benchmark cases were conducted to validate the code. Benchmark case I is MHD flow in a circular pipe with arbitrary electric conductivity of the walls in a uniform magnetic field. Benchmark cases II and III are experimental cases of 3D laminar steady MHD flow under fringing magnetic field. In all these cases, the numerical results match well with the benchmark cases.

  10. Further validation of liquid metal MHD code for unstructured grid based on OpenFOAM

    International Nuclear Information System (INIS)

    Feng, Jingchao; Chen, Hongli; He, Qingyun; Ye, Minyou

    2015-01-01

    Highlights: • Specific correction scheme has been adopted to revise the calculating result for non-orthogonal meshes. • The developed MHD code based on OpenFOAM platform has been validated by benchmark cases under uniform and non-uniform magnetic field in round and rectangular ducts. • ALEX experimental results have been used to validate the MHD code based on OpenFOAM. - Abstract: In fusion liquid metal blankets, complex geometries involving contractions, expansions, bends, manifolds are very common. The characteristics of liquid metal flow in these geometries are significant. In order to extend the magnetohydrodynamic (MHD) solver developed on OpenFOAM platform to be applied in the complex geometry, the MHD solver based on unstructured meshes has been implemented. The adoption of non-orthogonal correction techniques in the solver makes it possible to process the non-orthogonal meshes in complex geometries. The present paper focused on the validation of the code under critical conditions. An analytical solution benchmark case and two experimental benchmark cases were conducted to validate the code. Benchmark case I is MHD flow in a circular pipe with arbitrary electric conductivity of the walls in a uniform magnetic field. Benchmark cases II and III are experimental cases of 3D laminar steady MHD flow under fringing magnetic field. In all these cases, the numerical results match well with the benchmark cases.

  11. Open Source, Open Access, Open Review, Open Data. Initiativen zu mehr Offenheit in der digitalen Welt

    OpenAIRE

    Herb, Ulrich

    2011-01-01

    The article discusses the principles of openess, open access and open availability of information based on the examples of open access to scientific information, open government data, open geographical data and open source software.

  12. Piezoelectric response of a PZT thin film to magnetic fields from permanent magnet and coil combination

    Science.gov (United States)

    Guiffard, B.; Seveno, R.

    2015-01-01

    In this study, we report the magnetically induced electric field E 3 in Pb(Zr0.57Ti0.43)O3 (PZT) thin films, when they are subjected to both dynamic magnetic induction (magnitude B ac at 45 kHz) and static magnetic induction ( B dc) generated by a coil and a single permanent magnet, respectively. It is found that highest sensitivity to B dc——is achieved for the thin film with largest effective electrode. This magnetoelectric (ME) effect is interpreted in terms of coupling between eddy current-induced Lorentz forces (stress) in the electrodes of PZT and piezoelectricity. Such coupling was evidenced by convenient modelling of experimental variations of electric field magnitude with both B ac and B dc induction magnitudes, providing imperfect open circuit condition was considered. Phase angle of E 3 versus B dc could also be modelled. At last, the results show that similar to multilayered piezoelectric-magnetostrictive composite film, a PZT thin film made with a simple manufacturing process can behave as a static or dynamic magnetic field sensor. In this latter case, a large ME voltage coefficient of under B dc = 0.3 T was found. All these results may provide promising low-cost magnetic energy harvesting applications with microsized systems.

  13. Dilemmas within Commercial Involvement in Open Source Software

    DEFF Research Database (Denmark)

    Ciesielska, Malgorzata; Westenholz, Ann

    2016-01-01

    to free-riding. There are six levels of commercial involvement in open source communities, and each of them is characterized by a different dilemma. Originality/value – The paper sheds light on the various level of involvement of business in open source movement and emphasize that the popularized “open......Purpose – The purpose of this paper is to contribute to the literature about the commercial involvement in open source software, levels of this involvement and consequences of attempting to mix various logics of action. Design/methodology/approach – This paper uses the case study approach based...... on mixed methods: literature reviews and news searches, electronic surveys, qualitative interviews and observations. It combines discussions from several research projects as well as previous publications to present the scope of commercial choices within open source software and their consequences...

  14. Magnetic Doping and Kondo Effect in Bi 2 Se 3 Nanoribbons

    KAUST Repository

    Cha, Judy J.; Williams, James R.; Kong, Desheng; Meister, Stefan; Peng, Hailin; Bestwick, Andrew J.; Gallagher, Patrick; Goldhaber-Gordon, David; Cui, Yi

    2010-01-01

    A simple surface band structure and a large bulk band gap have allowed Bi2Se3 to become a reference material for the newly discovered three-dimensional topological insulators, which exhibit topologically protected conducting surface states that reside inside the bulk band gap. Studying topological insulators such as Bi2Se3 in nanostructures is advantageous because of the high surfaceto-volume ratio, which enhances effects from the surface states; recently reported Aharonov-Bohm oscillation in topological insulator nanoribbons by some of us is a good example. Theoretically, introducing magnetic impurities in topological insulators is predicted to open a small gap in the surface states by breaking time-reversal symmetry. Here, we present synthesis of magnetically doped Bi 2Se3 nanoribbons by vapor-liquid-solid growth using magnetic metal thin films as catalysts. Although the doping concentration is less than ∼2 %. low-temperature transport measurements of the Fe-doped Bi2Se3 nanoribbon devices show a clear Kondo effect at temperatures below 30 K, confirming the presence of magnetic impurities in the Bi2Se3 nanoribbons. The capability to dope topological insulator nanostructures magnetically opens up exciting opportunities for spintronics. © 2010 American Chemical Society.

  15. Magnetic Doping and Kondo Effect in Bi 2 Se 3 Nanoribbons

    KAUST Repository

    Cha, Judy J.

    2010-03-10

    A simple surface band structure and a large bulk band gap have allowed Bi2Se3 to become a reference material for the newly discovered three-dimensional topological insulators, which exhibit topologically protected conducting surface states that reside inside the bulk band gap. Studying topological insulators such as Bi2Se3 in nanostructures is advantageous because of the high surfaceto-volume ratio, which enhances effects from the surface states; recently reported Aharonov-Bohm oscillation in topological insulator nanoribbons by some of us is a good example. Theoretically, introducing magnetic impurities in topological insulators is predicted to open a small gap in the surface states by breaking time-reversal symmetry. Here, we present synthesis of magnetically doped Bi 2Se3 nanoribbons by vapor-liquid-solid growth using magnetic metal thin films as catalysts. Although the doping concentration is less than ∼2 %. low-temperature transport measurements of the Fe-doped Bi2Se3 nanoribbon devices show a clear Kondo effect at temperatures below 30 K, confirming the presence of magnetic impurities in the Bi2Se3 nanoribbons. The capability to dope topological insulator nanostructures magnetically opens up exciting opportunities for spintronics. © 2010 American Chemical Society.

  16. Magnetism in Medicine

    Science.gov (United States)

    Schenck, John

    2000-03-01

    For centuries physicians, scientists and others have postulated an important role, either as a cause of disease or as a mode of therapy, for magnetism in medicine. Although there is a straightforward role in the removal of magnetic foreign bodies, the majority of the proposed magnetic applications have been controversial and have often been attributed by mainstream practitioners to fraud, quackery or self-deception. Calculations indicate that many of the proposed methods of action, e.g., the field-induced alignment of water molecules or alterations in blood flow, are of negligible magnitude. Nonetheless, even at the present time, the use of small surface magnets (magnetotherapy) to treat arthritis and similar diseases is a widespread form of folk medicine and is said to involve sales of approximately one billion dollars per year. Another medical application of magnetism associated with Mesmer and others (eventually known as animal magnetism) has been discredited, but has had a culturally significant role in the development of hypnotism and as one of the sources of modern psychotherapy. Over the last two decades, in marked contrast to previous applications of magnetism to medicine, magnetic resonance imaging or MRI, has become firmly established as a clinical diagnostic tool. MRI permits the non-invasive study of subtle biological processes in intact, living organisms and approximately 150,000,000 diagnostic studies have been performed since its clinical introduction in the early 1980s. The dramatically swift and widespread acceptance of MRI was made possible by scientific and engineering advances - including nuclear magnetic resonance, computer technology and whole-body-sized, high field superconducting magnets - in the decades following World War Two. Although presently used much less than MRI, additional applications, including nerve and muscle stimulation by pulsed magnetic fields, the use of magnetic forces to guide surgical instruments, and imaging utilizing

  17. Open-Midplane Dipoles for a Muon Collider

    International Nuclear Information System (INIS)

    Weggel, R.; Gupta, R.; Kolonko, J.; Scanlan, R.; Cline, D.; Ding, X.; Anerella, M.; Kirk, H.; Palmer, B.; Schmalzle, J.

    2011-01-01

    For a muon collider with copious decay particles in the plane of the storage ring, open-midplane dipoles (OMD) may be preferable to tungsten-shielded cosine-theta dipoles of large aperture. The OMD should have its midplane completely free of material, so as to dodge the radiation from decaying muons. Analysis funded by a Phase I SBIR suggests that a field of 10-20 T should be feasible, with homogeneity of 1 x 10 -4 and energy deposition low enough for conduction cooling to 4.2 K helium. If funded, a Phase II SBIR would refine the analysis and build and test a proof-of-principle magnet. A Phase I SBIR has advanced the feasibility of open-midplane dipoles for the storage ring of a muon collider. A proposed Phase II SBIR would refine these predictions of stresses, deformations, field quality and energy deposition. Design optimizations would continue, leading to the fabrication and test, for the first time, of a proof-of-principle dipole of truly open-midplane design.

  18. Openly Published Environmental Sensing (OPEnS) | Advancing Open-Source Research, Instrumentation, and Dissemination

    Science.gov (United States)

    Udell, C.; Selker, J. S.

    2017-12-01

    The increasing availability and functionality of Open-Source software and hardware along with 3D printing, low-cost electronics, and proliferation of open-access resources for learning rapid prototyping are contributing to fundamental transformations and new technologies in environmental sensing. These tools invite reevaluation of time-tested methodologies and devices toward more efficient, reusable, and inexpensive alternatives. Building upon Open-Source design facilitates community engagement and invites a Do-It-Together (DIT) collaborative framework for research where solutions to complex problems may be crowd-sourced. However, barriers persist that prevent researchers from taking advantage of the capabilities afforded by open-source software, hardware, and rapid prototyping. Some of these include: requisite technical skillsets, knowledge of equipment capabilities, identifying inexpensive sources for materials, money, space, and time. A university MAKER space staffed by engineering students to assist researchers is one proposed solution to overcome many of these obstacles. This presentation investigates the unique capabilities the USDA-funded Openly Published Environmental Sensing (OPEnS) Lab affords researchers, within Oregon State and internationally, and the unique functions these types of initiatives support at the intersection of MAKER spaces, Open-Source academic research, and open-access dissemination.

  19. Near-Earth Magnetic Field Effects of Large-Scale Magnetospheric Currents

    Science.gov (United States)

    Luehr, Hermann; Xiong, Chao; Olsen, Nils; Le, Guan

    2016-01-01

    Magnetospheric currents play an important role in the electrodynamics of near- Earth space. This has been the topic of many space science studies. Here we focus on the magnetic fields they cause close to Earth. Their contribution to the geomagnetic field is the second largest after the core field. Significant progress in interpreting the magnetic fields from the different sources has been achieved thanks to magnetic satellite missions like Ørsted, CHAMP and now Swarm. Of particular interest for this article is a proper representation of the magnetospheric ring current effect. Uncertainties in modelling its effect still produce the largest residuals between observations and present-day geomagnetic field models. A lot of progress has been achieved so far, but there are still open issues like the characteristics of the partial ring current. Other currents discussed are those flowing in the magnetospheric tail. Also their magnetic contribution at LEO orbits is non-negligible. Treating them as an independent source is a more recent development, which has cured some of the problems in geomagnetic field modelling. Unfortunately there is no index available for characterizing the tail current intensity. Here we propose an approach that may help to properly quantify the magnetic contribution from the tail current for geomagnetic field modelling. Some open questions that require further investigation are mentioned at the end.

  20. Magnetic Topology of Coronal Hole Linkages

    Science.gov (United States)

    Titov, V. S.; Mikic, Z.; Linker, J. A.; Lionello, R.; Antiochos, S. K.

    2010-01-01

    In recent work, Antiochos and coworkers argued that the boundary between the open and closed field regions on the Sun can be extremely complex with narrow corridors of open ux connecting seemingly disconnected coronal holes from the main polar holes, and that these corridors may be the sources of the slow solar wind. We examine, in detail, the topology of such magnetic configurations using an analytical source surface model that allows for analysis of the eld with arbitrary resolution. Our analysis reveals three important new results: First, a coronal hole boundary can join stably to the separatrix boundary of a parasitic polarity region. Second, a single parasitic polarity region can produce multiple null points in the corona and, more important, separator lines connecting these points. Such topologies are extremely favorable for magnetic reconnection, because it can now occur over the entire length of the separators rather than being con ned to a small region around the nulls. Finally, the coronal holes are not connected by an open- eld corridor of finite width, but instead are linked by a singular line that coincides with the separatrix footprint of the parasitic polarity. We investigate how the topological features described above evolve in response to motion of the parasitic polarity region. The implications of our results for the sources of the slow solar wind and for coronal and heliospheric observations are discussed.

  1. Wake field in matched kicker magnet

    International Nuclear Information System (INIS)

    Miyahara, Y.

    1979-01-01

    Coherent transverse instability observed in KEK booster proton synchrotron has been reported previously. This instability is induced by the interaction of the beam with kicker magnet for the fast beam extraction. To understand the mechanism completely, it is necessary to know the wake field in detail. Here, the wake field or induced current in the kicker magnet which is terminated with matched resistance is considered

  2. Complex windmill transformation producing new purely magnetic fluids

    International Nuclear Information System (INIS)

    Lozanovski, C; Wylleman, L

    2011-01-01

    Minimal complex windmill transformations of G 2 IB(ii) spacetimes (admitting a two-dimensional Abelian group of motions of the so-called Wainwright B(ii) class) are defined and the compatibility with a purely magnetic Weyl tensor is investigated. It is shown that the transformed spacetimes cannot be perfect fluids or purely magnetic Einstein spaces. We then determine which purely magnetic perfect fluids (PMpfs) can be windmill-transformed into purely magnetic anisotropic fluids (PMafs). Assuming separation of variables, complete integration produces two, algebraically general, G 2 I-B(ii) PMpfs: a solution with zero 4-acceleration vector and spatial energy-density gradient, previously found by the authors, and a new solution in terms of Kummer's functions, where these vectors are aligned and non-zero. The associated windmill PMafs are rotating but non-expanding. Finally, an attempt to relate the spacetimes to each other by a simple procedure leads to a G 2 I-B(ii) one-parameter PMaf generalization of the previously found metric.

  3. Ab initio studies of magnetic anisotropy energy in highly Co-doped ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Łusakowski, A., E-mail: lusak@ifpan.edu.pl [Institute of Physics, Polish Academy of Sciences, Al. Lotników 32/46, PL-02668 Warsaw (Poland); Szuszkiewicz, W. [Institute of Physics, Polish Academy of Sciences, Al. Lotników 32/46, PL-02668 Warsaw (Poland); Faculty of Mathematics and Natural Sciences, University of Rzeszów, ul. S. Pigonia 1, PL-35959 Rzeszów (Poland)

    2017-03-15

    Density functional theory (DFT) calculations of the energy of magnetic anisotropy for diluted magnetic semiconductor (Zn,Co)O were performed using OpenMX package with fully relativistic pseudopotentials. The analysis of the band spin-orbit interaction and the magnetic ion's surrounding on magnetic anisotropy have been provided. As a result, the calculations show that the magnetic anisotropy in (Zn,Co)O solid solution, mainly of the single ion anisotropy type has been caused by Co ions. - Highlights: • The magnetic anisotropy in (Zn,Co)O is mainly due to anisotropy of single cobalt ion. • The magnetic anisotropy of (Zn,Co)O strongly depends on the nearest neighborhood of magnetic ion including local lattice deformations. • For (Zn,Co)O the energy of magnetic anisotropy is described by second order terms in magnetization.

  4. Seminal magnetic fields from inflato-electromagnetic inflation

    Energy Technology Data Exchange (ETDEWEB)

    Membiela, Federico Agustin; Bellini, Mauricio [Universidad Nacional de Mar del Plata, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Mar del Plata (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Instituto de Investigaciones Fisicas de Mar del Plata (IFIMAR), Buenos Aires (Argentina)

    2012-10-15

    We extend some previous attempts to explain the origin and evolution of primordial magnetic fields during inflation induced from a 5D vacuum. We show that the usual quantum fluctuations of a generalized 5D electromagnetic field cannot provide us with the desired magnetic seeds. We show that special fields without propagation on the extra non-compact dimension are needed to arrive at appreciable magnetic strengths. We also identify a new magnetic tensor field B{sub ij} in this kind of extra dimensional theory. Our results are in very good agreement with observational requirements, in particular from TeV blazars and CMB radiation limits we see that primordial cosmological magnetic fields should be close to scale invariance. (orig.)

  5. Seminal magnetic fields from inflato-electromagnetic inflation

    Science.gov (United States)

    Membiela, Federico Agustín; Bellini, Mauricio

    2012-10-01

    We extend some previous attempts to explain the origin and evolution of primordial magnetic fields during inflation induced from a 5D vacuum. We show that the usual quantum fluctuations of a generalized 5D electromagnetic field cannot provide us with the desired magnetic seeds. We show that special fields without propagation on the extra non-compact dimension are needed to arrive at appreciable magnetic strengths. We also identify a new magnetic tensor field B ij in this kind of extra dimensional theory. Our results are in very good agreement with observational requirements, in particular from TeV blazars and CMB radiation limits we see that primordial cosmological magnetic fields should be close to scale invariance.

  6. Seminal magnetic fields from inflato-electromagnetic inflation

    International Nuclear Information System (INIS)

    Membiela, Federico Agustin; Bellini, Mauricio

    2012-01-01

    We extend some previous attempts to explain the origin and evolution of primordial magnetic fields during inflation induced from a 5D vacuum. We show that the usual quantum fluctuations of a generalized 5D electromagnetic field cannot provide us with the desired magnetic seeds. We show that special fields without propagation on the extra non-compact dimension are needed to arrive at appreciable magnetic strengths. We also identify a new magnetic tensor field B ij in this kind of extra dimensional theory. Our results are in very good agreement with observational requirements, in particular from TeV blazars and CMB radiation limits we see that primordial cosmological magnetic fields should be close to scale invariance. (orig.)

  7. The overview and history of permanent magnet devices in accelerator technology

    International Nuclear Information System (INIS)

    Kraus, R.H.

    1994-01-01

    This paper looks at the early history of accelerator development with a particular focus on the important discoveries that opened the door for the application of permanent-magnet materials to this area of science. Researchers began to use permanent-magnet materials in particle accelerators soon after the invention of the alternating gradient principle, that showed magnetic fields could be used to control the transverse envelope of charged-particle beams. Since that time, permanent-magnet materials have found wide application in the modern charged particle accelerator. A brief history of permanent-magnet use in accelerator physics and technology is outlined, some of the general design considerations are presented, and several material properties of concern for particle accelerator applications are discussed

  8. The overview and history of permanent magnet devices in accelerator technology

    International Nuclear Information System (INIS)

    Kraus, R.H. Jr.

    1993-01-01

    This paper reviews the early history of accelerator development with a particular focus on the important discoveries that opened the door for the application of permanent-magnet materials to this area of science. Researchers began to use permanent-magnet materials in particle accelerators soon after the invention of the alternating gradient principle, that showed magnetic fields could be used to control the transverse envelope of charged-particle beams. Since that time, permanent-magnet materials have found wide application in the modern charged particle accelerator. The history of permanent-magnet use in accelerator physics and technology is outlined, general design considerations are presented, and material properties of concern for particle accelerator applications are discussed

  9. Radiation considerations for superconducting fusion magnets

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1977-01-01

    Radiation environment for the magnets is characterized for various conditions expected for tokamak power reactor operation. The radiation levels are translated into radiation effects using available experimental data. The impact of the tradeoffs in radiation shielding and the change in the properties of the superconducting magnets on reactor performance and economics is examined. It is shown that (1) superconducting magnets in fusion reactors will operate at much higher radiation level than was previously anticipated; (2) additional data on radiation damage is required to better accuracy than is presently available in order to accurately quantify the change in properties in the superconducting magnet components; and (3) there is a substantial penalty for increasing (or overestimating) the shielding requirements. A perspective of future tokamak power reactors is presented and questions relating to desirable magnetic field strength and selection of materials for superconducting magnets are briefly examined

  10. Analytical theory of noncollinear amorphous metallic magnetism

    International Nuclear Information System (INIS)

    Kakehashi, Y.; Uchida, T.

    2001-01-01

    Analytical theory of noncollinear magnetism in amorphous metals is proposed on the basis of the Gaussian model for the distribution of the interatomic distance and the saddle-point approximation. The theory removes the numerical difficulty in the previous theory based on the Monte-Carlo sampling method, and reasonably describes the magnetic properties of amorphous transition metals

  11. Study of a magnetically oriented lyotropic mesophase

    International Nuclear Information System (INIS)

    Amaral, L.Q.; Pimentel, C.A.; Tavares, M.R.; Vanin, J.A.

    A study of a magnetically oriented lyomesophase formed by a quaternary system (Na decyl sulfate/water/decanol/ Na sulfate) is reported. Small angle X-ray diffraction measurements have been performed on unoriented samples and samples previously subjected to the action of magnetic fields (H vector). A model of finite planar micelles surrounded by water is proposed [pt

  12. Light-free magnetic resonance force microscopy for studies of electron spin polarized systems

    International Nuclear Information System (INIS)

    Pelekhov, Denis V.; Selcu, Camelia; Banerjee, Palash; Chung Fong, Kin; Chris Hammel, P.; Bhaskaran, Harish; Schwab, Keith

    2005-01-01

    Magnetic resonance force microscopy is a scanned probe technique capable of three-dimensional magnetic resonance imaging. Its excellent sensitivity opens the possibility for magnetic resonance studies of spin accumulation resulting from the injection of spin polarized currents into a para-magnetic collector. The method is based on mechanical detection of magnetic resonance which requires low noise detection of cantilever displacement; so far, this has been accomplished using optical interferometry. This is undesirable for experiments on doped silicon, where the presence of light is known to enhance spin relaxation rates. We report a non-optical displacement detection scheme based on sensitive microwave capacitive readout

  13. Design and Finite Element Analysis of a Novel Transverse Flux Permanent Magnet Disk Generator

    DEFF Research Database (Denmark)

    Hosseini, Seyedmohsen; Moghani, Javad Shokrollahi; Ershad, Nima Farrokhzad

    2011-01-01

    This paper presents a novel structure of a transverse flux permanent magnet disk generator. The proposed disk shape structure simplifies prototyping by using simple laminated steel sheets in comparison with previous transverse flux structures that employ bent laminations and soft magnetic...... composites. Also the proposed structure has a higher power factor than what has been reported previously for transverse flux permanent magnet structures. After introducing the transverse flux permanent magnet disk generator, the design process is explained and a small power generator is designed...

  14. New color-magnetic defects in dense quark matter

    Science.gov (United States)

    Haber, Alexander; Schmitt, Andreas

    2018-06-01

    Color-flavor locked (CFL) quark matter expels color-magnetic fields due to the Meissner effect. One of these fields carries an admixture of the ordinary abelian magnetic field and therefore flux tubes may form if CFL matter is exposed to a magnetic field, possibly in the interior of neutron stars or in quark stars. We employ a Ginzburg–Landau approach for three massless quark flavors, which takes into account the multi-component nature of color superconductivity. Based on the weak-coupling expressions for the Ginzburg–Landau parameters, we identify the regime where CFL is a type-II color superconductor and compute the radial profiles of different color-magnetic flux tubes. Among the configurations without baryon circulation we find a new solution that is energetically preferred over the flux tubes previously discussed in the literature in the parameter regime relevant for compact stars. Within the same setup, we also find a new defect in the 2SC phase, namely magnetic domain walls, which emerge naturally from the previously studied flux tubes if a more general ansatz for the order parameter is used. Color-magnetic defects in the interior of compact stars allow for sustained deformations of the star, potentially strong enough to produce detectable gravitational waves.

  15. Open access, open education resources and open data in Uganda ...

    African Journals Online (AJOL)

    As a follow up to OpenCon 2014, International Federation of Medical Students' Associations (IFMSA) students organized a 3 day workshop Open Access, Open Education Resources and Open Data in Kampala from 15-18 December 2014. One of the aims of the workshop was to engage the Open Access movement in ...

  16. Novel High Temperature Magnetic Bearings for Space Vehicle Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Previous high temperature magnetic bearings employed electromagnets only. The work proposed in this SBIR program seeks to utilize High Temperature Permanent Magnets...

  17. Novel High Temperature Magnetic Bearings for Space Vehicle Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Previous high temperature magnetic bearings employed only electromagnets. The work proposed in this SBIR program seeks to utilize High Temperature Permanent Magnets...

  18. Maximal conservation and minimal usage of blood products in open heart surgery.

    Science.gov (United States)

    Newland, P E; Pastoriza-Pinol, J; McMillan, J; Smith, B F; Stirling, G R

    1980-05-01

    Open heart surgery has previously been associated with the use of large volumes of blood products. This paper describes methods of blood conservation and a simple method of intraoperative autotransfusion that together have resulted in minimal blood product usage in elective open heart surgery cases. This has reduced our dependence on blood bank supplies for the performance of elective open heart surgery.

  19. Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and 60Co γ-rays

    International Nuclear Information System (INIS)

    Alderman, J.; Job, P. K.; Puhl, J.

    2000-01-01

    The Advanced Photon Source (APS), as well as other third-generation synchrotron light sources, uses permanent magnets in the insertion devices to produce x-rays for scientific research. When placed in a high-energy storage ring, these permanent magnets are subjected to irradiation from synchrotron radiation, high-energy bremsstrahlung, and bremsstrahlung-produced photoneutrons. Previous investigations have exhibited varying degrees of degradation in the intensity of magnetization of these magnets due to irradiation from electron beams, 60 Co γrays, and high-energy neutrons. The APS specifically uses Nd-Fe-B permanent magnets in their insertion devices. Although no detectable radiation-induced demagnetization has been observed in the APS insertion devices so far, partial demagnetization has been observed in at least one insertion device at the European Synchrotron Radiation Facility (ESRF), where Nd-Fe-B permanent magnets are also used

  20. New methods of magnet-based instrumentation for NOTES.

    Science.gov (United States)

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.