WorldWideScience

Sample records for previous all-time high

  1. In the Dark Shadow of the Supercycle Tailings Failure Risk & Public Liability Reach All Time Highs

    Directory of Open Access Journals (Sweden)

    Lindsay Newland Bowker

    2017-10-01

    Full Text Available This is the third in a series of independent research papers attempting to improve the quality of descriptive data and analysis of tailings facility failures globally focusing on the relative occurrence, severity and root causes of these failures. This paper updates previously published failures data through 2010 with both additional data pre-2010 and additional data 2010–2015. All three papers have explored the connection between high public consequence failure trends and mining economics trends especially grade, costs to produce and price. This work, the third paper, looks more deeply at that connection through several autopsies of the dysfunctional economics of the period 2000–2010 in which the greatest and longest price increase in recorded history co-occurred across all commodities, a phenomenon sometimes called a supercycle. That high severity failures reached all-time highs in the same decade as prices rose to highs, unprecedented since 1916, challenges many fundamental beliefs and assumptions that have governed modern mining operations, investment decisions, and regulation. It is from waste management in mining, a non-revenue producing cost incurring part of every operation, that virtually all severe environmental and community damages arise. These damages are now more frequently at a scale and of a nature that is non-remediable and beyond any possibility of clean up or reclamation. The authors have jointly undertaken this work in the public interest without funding from the mining industry, regulators, non-governmental organizations, or from any other source.

  2. Previous utilization of service does not improve timely booking in ...

    African Journals Online (AJOL)

    Previous utilization of service does not improve timely booking in antenatal care: Cross sectional study ... Journal Home > Vol 24, No 3 (2010) > ... Results: Past experience on antenatal care service utilization did not come out as a predictor for ...

  3. The High Time Resolution Universe surveys for pulsars and fast transients

    Science.gov (United States)

    Keith, Michael J.

    2013-03-01

    The High Time Resolution Universe survey for pulsars and transients is the first truly all-sky pulsar survey, taking place at the Parkes Radio Telescope in Australia and the Effelsberg Radio Telescope in Germany. Utilising multibeam receivers with custom built all-digital recorders the survey targets the fastest millisecond pulsars and radio transients on timescales of 64 μs to a few seconds. The new multibeam digital filter-bank system at has a factor of eight improvement in frequency resolution over previous Parkes multibeam surveys, allowing us to probe further into the Galactic plane for short duration signals. The survey is split into low, mid and high Galactic latitude regions. The mid-latitude portion of the southern hemisphere survey is now completed, discovering 107 previously unknown pulsars, including 26 millisecond pulsars. To date, the total number of discoveries in the combined survey is 135 and 29 MSPs These discoveries include the first magnetar to be discovered by it's radio emission, unusual low-mass binaries, gamma-ray pulsars and pulsars suitable for pulsar timing array experiments.

  4. Single reaction, real time RT-PCR detection of all known avian and human metapneumoviruses.

    Science.gov (United States)

    Lemaitre, E; Allée, C; Vabret, A; Eterradossi, N; Brown, P A

    2018-01-01

    Current molecular methods for the detection of avian and human metapneumovirus (AMPV, HMPV) are specifically targeted towards each virus species or individual subgroups of these. Here a broad range SYBR Green I real time RT-PCR was developed which amplified a highly conserved fragment of sequence in the N open reading frame. This method was sufficiently efficient and specific in detecting all MPVs. Its validation according to the NF U47-600 norm for the four AMPV subgroups estimated low limits of detection between 1000 and 10copies/μL, similar with detection levels described previously for real time RT-PCRs targeting specific subgroups. RNA viruses present a challenge for the design of durable molecular diagnostic test due to the rate of change in their genome sequences which can vary substantially in different areas and over time. The fact that the regions of sequence for primer hybridization in the described method have remained sufficiently conserved since the AMPV and HMPV diverged, should give the best chance of continued detection of current subgroups and of potential unknown or future emerging MPV strains. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Discovery of an All-Pervading Previously Unknown Longitudinal Wave

    Science.gov (United States)

    Wagner, Orvin E.

    2002-04-01

    In 1988 a new species of longitudinal sound like wave was identified in this laboratory. These waves travel through (dark matter filled) vacuum as well as through ordinary matter. So far as is known these waves always appear as standing waves. The data suggest that they organize plants, organize structures in manipulated granular materials, organize planetary systems, and other structures of the universe. They are likely the basis for the beginnings of life and are closely associated with quantum waves. The repeating structures that they produce suggest that they are a basis for fractal structures. Their velocities appear to be a function of the medium as well as the timing of their sources since quantized velocities have been found. 12 years of data collected in this laboratory suggest that the waves are all pervading but they still interact with ordinary matter. These waves apparently provide for the stability of the solar system and probably the whole universe. They interact with gravity within plants, for example, to provide a basis for a plant's response to gravity. See the Wagner web site.

  6. All passive architecture for high efficiency cascaded Raman conversion

    Science.gov (United States)

    Balaswamy, V.; Arun, S.; Chayran, G.; Supradeepa, V. R.

    2018-02-01

    Cascaded Raman fiber lasers have offered a convenient method to obtain scalable, high-power sources at various wavelength regions inaccessible with rare-earth doped fiber lasers. A limitation previously was the reduced efficiency of these lasers. Recently, new architectures have been proposed to enhance efficiency, but this came at the cost of enhanced complexity, requiring an additional low-power, cascaded Raman laser. In this work, we overcome this with a new, all-passive architecture for high-efficiency cascaded Raman conversion. We demonstrate our architecture with a fifth-order cascaded Raman converter from 1117nm to 1480nm with output power of ~64W and efficiency of 60%.

  7. Leisure-time physical activity and all-cause mortality.

    Science.gov (United States)

    Lahti, Jouni; Holstila, Ansku; Lahelma, Eero; Rahkonen, Ossi

    2014-01-01

    Physical inactivity is a major public health problem associated with increased mortality risk. It is, however, poorly understood whether vigorous physical activity is more beneficial for reducing mortality risk than activities of lower intensity. The aim of this study was to examine associations of the intensity and volume of leisure-time physical activity with all-cause mortality among middle-aged women and men while considering sociodemographic and health related factors as covariates. Questionnaire survey data collected in 2000-02 among 40-60-year-old employees of the City of Helsinki (N = 8960) were linked with register data on mortality (74% gave permission to the linkage) providing a mean follow-up time of 12-years. The analysis included 6429 respondents (79% women). The participants were classified into three groups according to intensity of physical activity: low moderate, high moderate and vigorous. The volume of physical activity was classified into three groups according to tertiles. Cox regression analysis was used to calculate hazard ratios (HR) and 95% confidence intervals (CIs) for all-cause mortality. During the follow up 205 participants died. Leisure-time physical activity was associated with reduced risk of mortality. After adjusting for covariates the vigorous group (HR = 0.54, 95% CI 0.34-0.86) showed a reduced risk of mortality compared with the low moderate group whereas for the high moderate group the reductions in mortality risk (HR = 0.72, 95% CI 0.48-1.08) were less clear. Adjusting for the volume of physical activity did not affect the point estimates. Higher volume of leisure-time physical activity was also associated with reduced mortality risk; however, adjusting for the covariates and the intensity of physical activity explained the differences. For healthy middle-aged women and men who engage in some physical activity vigorous exercise may provide further health benefits preventing premature deaths.

  8. Ovarian responses and pregnancy rate with previously used intravaginal progesterone releasing devices for fixed-time artificial insemination in sheep.

    Science.gov (United States)

    Vilariño, M; Rubianes, E; Menchaca, A

    2013-01-01

    The objective was to determine serum progesterone concentrations, ovarian responses, and pregnancy rate in sheep inseminated following a short-term protocol (6 days of treatment) with a previously used controlled internal drug release-G (CIDR-G) device. In experiment 1, 30 ewes were put on a short-term protocol using a CIDR-G of first use (new devices, N = 10), second use (previously used for 6 days, N = 10), or third use (previously used twice for 6 days, N = 10). All ewes were given prostaglandin F(2α) (10 mg dinoprost) and eCG (300 IU) im at device withdrawal. Mean serum progesterone concentrations were greater for ewes treated with new versus reused devices (P synchronization and ovulation, with lower serum progesterone concentrations for reused devices. Three times used CIDR-G yielded a pregnancy rate >70%, which tended to be lower than that obtained with new devices, adding evidence of the detrimental effect of low serum progesterone concentrations on fertility in sheep. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Cancer-Specific and All-Cause Mortality in Kidney Transplant Recipients With and Without Previous Cancer.

    Science.gov (United States)

    Viecelli, Andrea K; Lim, Wai H; Macaskill, Petra; Chapman, Jeremy R; Craig, Jonathan C; Clayton, Philip; Cohney, Solomon; Carroll, Robert; Wong, Germaine

    2015-12-01

    For dialysis patients with a cancer history, a period of surveillance is generally recommended before listing for transplantation. However, the outcomes of patients with cancer recurrence and/or a second primary cancer after transplantation are unknown. To determine the prognosis of kidney transplant recipients who developed cancer after transplantation and whether this varied with cancer types (first cancer, recurrence, second primary cancer). Using data from the Australian and New Zealand Dialysis and Transplant Registry, we compared the cancer-specific and all-cause mortality among recipients with different cancer types using adjusted Cox proportional hazard models. Of the 21,415 recipients transplanted between 1965 and 2012, 3% (651 of 21,415) had a previous cancer history. A total of 2840 (13%) recipients developed cancer after the first transplant, of whom 2760 (97.2%) developed a first cancer, 23 (0.8%) experienced cancer recurrence, and 57 (2%) developed a second primary cancer. There were no significant differences in the risks of cancer-specific and all-cause mortality between recipients who developed their first cancer after transplant, those with cancer recurrence (adjusted hazard ratios [aHRs], 0.79; 95% confidence interval [95% CI], 0.38-1.67; P = 0.54 and aHRs, 0.86; 95% CI, 0.45-1.66; P = 0.66, respectively) and recipients who developed a second primary cancer after transplantation (aHRs, 1.01; 95%CI, 0.63-1.62; P = 0.95 and aHRs, 1.16; 95% CI, 0.79-1.69; P = 0.45, respectively). Among patients with a previous history of malignancy, recurrent and second primary cancers are infrequent after renal transplantation. A history of previous malignancy does not have an additive effect on the cancer-specific and overall survival of kidney transplant recipients who develop cancer.

  10. High speed all-silicon optical modulator

    International Nuclear Information System (INIS)

    Marris-Morini, Delphine; Le Roux, Xavier; Pascal, Daniel; Vivien, Laurent; Cassan, Eric; Fedeli, Jean Marc; Damlencourt, Jean Francois; Bouville, David; Palomo, Jose; Laval, Suzanne

    2006-01-01

    Electrorefractive effect is experimentally demonstrated in an all-silicon optical structure. A highly doped Si P + layer is embedded in the intrinsic region of a PIN diode integrated in a SOI waveguide. Holes are confined at equilibrium around the P + layer. By applying a reverse bias to the diode, electrical field sweeps the carriers out of the active region. Free carrier concentration variations are responsible for local refractive index variations leading to an effective index variation of the waveguide optical mode and to an optical absorption variation. As a figure of merit, the product V π L π , determined from the measured effective index variation, is equal to 3.1 V cm. Furthermore, the device performances have theoretically been investigated. Estimations show that V π L π as small as 1 V cm are feasible using optimized structures. Response times lower than 2 ps are predicted, which gives the possibility to achieve very high-speed modulation. Furthermore, a temperature increases from 300 to 400 K does not change the index variation amplitude, and despite the carrier mobility reduction, response times are still lower than 2 ps

  11. Outcome of secondary high-grade glioma in children previously treated for a malignant condition: A study of the Canadian Pediatric Brain Tumour Consortium

    International Nuclear Information System (INIS)

    Carret, Anne-Sophie; Tabori, Uri; Crooks, Bruce; Hukin, Juliette; Odame, Isaac; Johnston, Donna L.; Keene, Daniel L.; Freeman, Carolyn; Bouffet, Eric

    2006-01-01

    Background and purpose: Reports of secondary high-grade glioma (HGG) in survivors of childhood cancer are scarce. The aim of this study was to review the pattern of diagnosis, the treatment, and outcome of secondary pediatric HGG. Patients and methods: We performed a multi-center retrospective study among the 17 paediatric institutions participating in the Canadian Pediatric Brain Tumour Consortium (CPBTC). Results: We report on 18 patients (14 males, 4 females) treated in childhood for a primary cancer, who subsequently developed a HGG as a second malignancy. All patients had previously received radiation therapy +/- chemotherapy for either acute lymphoblastic leukaemia (n = 9) or solid tumour (n = 9). All HGG occurred within the previous radiation fields. At the last follow-up, 17 patients have died and the median survival time is 9.75 months. Conclusion: Although aggressive treatment seems to provide sustained remissions in some patients, the optimal management is still to be defined. Further documentation of such cases is necessary in order to better understand the pathogenesis, the natural history and the prevention of these tumours

  12. Previously unknown species of Aspergillus.

    Science.gov (United States)

    Gautier, M; Normand, A-C; Ranque, S

    2016-08-01

    The use of multi-locus DNA sequence analysis has led to the description of previously unknown 'cryptic' Aspergillus species, whereas classical morphology-based identification of Aspergillus remains limited to the section or species-complex level. The current literature highlights two main features concerning these 'cryptic' Aspergillus species. First, the prevalence of such species in clinical samples is relatively high compared with emergent filamentous fungal taxa such as Mucorales, Scedosporium or Fusarium. Second, it is clearly important to identify these species in the clinical laboratory because of the high frequency of antifungal drug-resistant isolates of such Aspergillus species. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been shown to enable the identification of filamentous fungi with an accuracy similar to that of DNA sequence-based methods. As MALDI-TOF MS is well suited to the routine clinical laboratory workflow, it facilitates the identification of these 'cryptic' Aspergillus species at the routine mycology bench. The rapid establishment of enhanced filamentous fungi identification facilities will lead to a better understanding of the epidemiology and clinical importance of these emerging Aspergillus species. Based on routine MALDI-TOF MS-based identification results, we provide original insights into the key interpretation issues of a positive Aspergillus culture from a clinical sample. Which ubiquitous species that are frequently isolated from air samples are rarely involved in human invasive disease? Can both the species and the type of biological sample indicate Aspergillus carriage, colonization or infection in a patient? Highly accurate routine filamentous fungi identification is central to enhance the understanding of these previously unknown Aspergillus species, with a vital impact on further improved patient care. Copyright © 2016 European Society of Clinical Microbiology and

  13. Homologous tracheal transplantation with grafts previously exposed to high doses of gamma radiation in dogs without immunosuppressive agents

    International Nuclear Information System (INIS)

    Yokomise, Hiroyasu; Inui, Kenji; Kure, Toshio; Wada, Hiromi; Itomi, Shigeki

    1993-01-01

    The study was designed to determine whether previous high doses irradiation of gamma radiation would contribute to tracheal transplantation with no use of immunosuppressive agents. Twenty mongrel dogs were used as experimental animals. Five rings of thoracic tracheas, which were extracted from recipients, were exposed to 20000, 50000, or 100000 cGy in each 5 dogs. Five other non-irradiated dogs served as controls. Irradiated tracheal grafts were transplanted and covered with pedicled omentum. After transplantation, no immunosuppressive agents were given to dogs. All dogs in the control group died of tracheal stenosis due to graft-host rejection within one month. All but one long-term survivor died of tracheal stenosis, as well, in both the 20000 cGy and 50000 cGy groups. In the 100000 cGy group, grafts became viable in 4 dogs, and three of these survived one year or more. In conclusion, previous irradiation with high doses of 100000 cGy allowed homologous tracheal transplantation even when no immunosuppressive agents are given. (N.K.)

  14. All-optical signal processing of OTDM and OFDM signals based on time-domain Optical Fourier Transformation

    DEFF Research Database (Denmark)

    Clausen, Anders; Guan, Pengyu; Mulvad, Hans Christian Hansen

    2014-01-01

    All-optical time-domain Optical Fourier Transformation utilised for signal processing of ultra-high-speed OTDM signals and OFDM signals will be presented.......All-optical time-domain Optical Fourier Transformation utilised for signal processing of ultra-high-speed OTDM signals and OFDM signals will be presented....

  15. Daily sitting time and all-cause mortality: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Josephine Y Chau

    Full Text Available To quantify the association between daily total sitting and all-cause mortality risk and to examine dose-response relationships with and without adjustment for moderate-to-vigorous physical activity.Studies published from 1989 to January 2013 were identified via searches of multiple databases, reference lists of systematic reviews on sitting and health, and from authors' personal literature databases. We included prospective cohort studies that had total daily sitting time as a quantitative exposure variable, all-cause mortality as the outcome and reported estimates of relative risk, or odds ratios or hazard ratios with 95% confidence intervals. Two authors independently extracted the data and summary estimates of associations were computed using random effects models.Six studies were included, involving data from 595,086 adults and 29,162 deaths over 3,565,569 person-years of follow-up. Study participants were mainly female, middle-aged or older adults from high-income countries; mean study quality score was 12/15 points. Associations between daily total sitting time and all-cause mortality were not linear. With physical activity adjustment, the spline model of best fit had dose-response HRs of 1.00 (95% CI: 0.98-1.03, 1.02 (95% CI: 0.99-1.05 and 1.05 (95% CI: 1.02-1.08 for every 1-hour increase in sitting time in intervals between 0-3, >3-7 and >7 h/day total sitting, respectively. This model estimated a 34% higher mortality risk for adults sitting 10 h/day, after taking physical activity into account. The overall weighted population attributable fraction for all-cause mortality for total daily sitting time was 5.9%, after adjusting for physical activity.Higher amounts of daily total sitting time are associated with greater risk of all-cause mortality and moderate-to-vigorous physical activity appears to attenuate the hazardous association. These findings provide a starting point for identifying a threshold on which to base clinical and public

  16. High resolution multi-scale air quality modelling for all streets in Denmark

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Becker, Thomas

    2017-01-01

    The annual concentrations of NO2, PM2.5 and PM10 in 2012 have for the first time been modelled for all 2.4 million addresses in Denmark based on a multi-scale air quality modelling approach. All addresses include residential, industrial, institutional, shop, school, restaurant addresses etc...... concentrations of NO2 for the five available street monitoring stations are within −27% to +12%. The model results were also verified with comparisons with previous model results for NO2 at 98 selected streets in Copenhagen and 31 streets in Aalborg. The verification showed good correlation in Copenhagen (r2 = 0...

  17. All-electronic droplet generation on-chip with real-time feedback control for EWOD digital microfluidics.

    Science.gov (United States)

    Gong, Jian; Kim, Chang-Jin C J

    2008-06-01

    Electrowetting-on-dielectric (EWOD) actuation enables digital (or droplet) microfluidics where small packets of liquids are manipulated on a two-dimensional surface. Due to its mechanical simplicity and low energy consumption, EWOD holds particular promise for portable systems. To improve volume precision of the droplets, which is desired for quantitative applications such as biochemical assays, existing practices would require near-perfect device fabrication and operation conditions unless the droplets are generated under feedback control by an extra pump setup off of the chip. In this paper, we develop an all-electronic (i.e., no ancillary pumping) real-time feedback control of on-chip droplet generation. A fast voltage modulation, capacitance sensing, and discrete-time PID feedback controller are integrated on the operating electronic board. A significant improvement is obtained in the droplet volume uniformity, compared with an open loop control as well as the previous feedback control employing an external pump. Furthermore, this new capability empowers users to prescribe the droplet volume even below the previously considered minimum, allowing, for example, 1 : x (x < 1) mixing, in comparison to the previously considered n : m mixing (i.e., n and m unit droplets).

  18. ALL-ELECTRONIC DROPLET GENERATION ON-CHIP WITH REAL-TIME FEEDBACK CONTROL FOR EWOD DIGITIAL MICROFLUIDICS

    Science.gov (United States)

    Gong, Jian; Kim, Chang-Jin “CJ”

    2009-01-01

    Electrowetting-on-dielectric (EWOD) actuation enables digital (or droplet) microfluidics where small packets of liquids are manipulated on a two-dimensional surface. Due to its mechanical simplicity and low energy consumption, EWOD holds particular promise for portable systems. To improve volume precision of the droplets, which is desired for quantitative applications such as biochemical assays, existing practices would require near-perfect device fabricaion and operation conditions unless the droplets are generated under feedback control by an extra pump setup off of the chip. In this paper, we develop an all-electronic (i.e., no ancillary pumping) real-time feedback control of on-chip droplet generation. A fast voltage modulation, capacitance sensing, and discrete-time PID feedback controller are integrated on the operating electronic board. A significant improvement is obtained in the droplet volume uniformity, compared with an open loop control as well as the previous feedback control employing an external pump. Furthermore, this new capability empowers users to prescribe the droplet volume even below the previously considered minimum, allowing, for example, 1:x (x < 1) mixing, in comparison to the previously considered n:m mixing (i.e., n and m unit droplets). PMID:18497909

  19. Highly flexible and all-solid-state paperlike polymer supercapacitors.

    Science.gov (United States)

    Meng, Chuizhou; Liu, Changhong; Chen, Luzhuo; Hu, Chunhua; Fan, Shoushan

    2010-10-13

    In recent years, much effort have been dedicated to achieve thin, lightweight and even flexible energy-storage devices for wearable electronics. Here we demonstrate a novel kind of ultrathin all-solid-state supercapacitor configuration with an extremely simple process using two slightly separated polyaniline-based electrodes well solidified in the H(2)SO(4)-polyvinyl alcohol gel electrolyte. The thickness of the entire device is much comparable to that of a piece of commercial standard A4 print paper. Under its highly flexible (twisting) state, the integrate device shows a high specific capacitance of 350 F/g for the electrode materials, well cycle stability after 1000 cycles and a leakage current of as small as 17.2 μA. Furthermore, due to its polymer-based component structure, it has a specific capacitance of as high as 31.4 F/g for the entire device, which is more than 6 times that of current high-level commercial supercapacitor products. These highly flexible and all-solid-state paperlike polymer supercapacitors may bring new design opportunities of device configuration for energy-storage devices in the future wearable electronic area.

  20. 10 Gb/s Real-Time All-VCSEL Low Complexity Coherent scheme for PONs

    DEFF Research Database (Denmark)

    Rodes Lopez, Roberto; Cheng, Ning; Jensen, Jesper Bevensee

    2012-01-01

    Real time demodulation of a 10 Gb/s all-VCSEL based coherent PON link with a simplified coherent receiver scheme is demonstrated. Receiver sensitivity of −33 dBm is achieved providing high splitting ratio and link reach....

  1. Risks of cardiovascular adverse events and death in patients with previous stroke undergoing emergency noncardiac, nonintracranial surgery

    DEFF Research Database (Denmark)

    Christiansen, Mia N.; Andersson, Charlotte; Gislason, Gunnar H.

    2017-01-01

    Background: The outcomes of emergent noncardiac, nonintracranial surgery in patients with previous stroke remain unknown. Methods: All emergency surgeries performed in Denmark (2005 to 2011) were analyzed according to time elapsed between previous ischemic stroke and surgery. The risks of 30-day...... mortality and major adverse cardiovascular events were estimated as odds ratios (ORs) and 95% CIs using adjusted logistic regression models in a priori defined groups (reference was no previous stroke). In patients undergoing surgery immediately (within 1 to 3 days) or early after stroke (within 4 to 14...... and general anesthesia less frequent in patients with previous stroke (all P Risks of major adverse cardiovascular events and mortality were high for patients with stroke less than 3 months (20.7 and 16.4% events; OR = 4.71 [95% CI, 4.18 to 5.32] and 1.65 [95% CI, 1.45 to 1.88]), and remained...

  2. High speed all optical shear wave imaging optical coherence elastography (Conference Presentation)

    Science.gov (United States)

    Song, Shaozhen; Hsieh, Bao-Yu; Wei, Wei; Shen, Tueng; O'Donnell, Matthew; Wang, Ruikang K.

    2016-03-01

    Optical Coherence Elastography (OCE) is a non-invasive testing modality that maps the mechanical property of soft tissues with high sensitivity and spatial resolution using phase-sensitive optical coherence tomography (PhS-OCT). Shear wave OCE (SW-OCE) is a leading technique that relies on the speed of propagating shear waves to provide a quantitative elastography. Previous shear wave imaging OCT techniques are based on repeated M-B scans, which have several drawbacks such as long acquisition time and repeated wave stimulations. Recent developments of Fourier domain mode-locked high-speed swept-source OCT system has enabled enough speed to perform KHz B-scan rate OCT imaging. Here we propose ultra-high speed, single shot shear wave imaging to capture single-shot transient shear wave propagation to perform SW-OCE. The frame rate of shear wave imaging is 16 kHz, at A-line rate of ~1.62 MHz, which allows the detection of high-frequency shear wave of up to 8 kHz. The shear wave is generated photothermal-acoustically, by ultra-violet pulsed laser, which requires no contact to OCE subjects, while launching high frequency shear waves that carries rich localized elasticity information. The image acquisition and processing can be performed at video-rate, which enables real-time 3D elastography. SW-OCE measurements are demonstrated on tissue-mimicking phantoms and porcine ocular tissue. This approach opens up the feasibility to perform real-time 3D SW-OCE in clinical applications, to obtain high-resolution localized quantitative measurement of tissue biomechanical property.

  3. Working time autonomy and time adequacy: What if performance is all that counts?

    OpenAIRE

    Lott, Yvonne

    2014-01-01

    To be able to combine work with activities and duties outside the workplace successfully, employees need time adequacy. Time adequacy is the fit between working time and all other time demands and can be achieved through working time flexibility and autonomy. However, past research has shown that working time flexibility and autonomy do not necessarily foster employees' time sovereignty. Studies suggest that the benefits of working time arrangements depend on work organization. Analyzing perf...

  4. Perceived benefits and barriers to leisure-time physical activity during pregnancy in previously inactive and active women.

    Science.gov (United States)

    Da Costa, Deborah; Ireland, Kierla

    2013-01-01

    This study compared perceived benefits and barriers to leisure-time physical activity during pregnancy among women who were insufficiently active or inactive before pregnancy. Eighty-two pregnant women completed questionnaires assessing leisure-time physical activity benefits/barriers, exercise self-efficacy, social support, depressed mood, pre-pregnancy and current physical activity and fatigue. Multivariable regression analyses identified factors associated with exercise benefits/barriers for the two pre-pregnancy leisure-time physical activity groups. Both pre-pregnancy leisure-time physical activity groups reported more benefits than barriers to exercise during pregnancy. Previously inactive women reported fewer perceived benefits and greater perceived barriers to leisure-time physical activity during pregnancy. Higher self-efficacy for exercise during pregnancy was significantly associated with greater benefits of leisure-time physical activity during pregnancy for both groups. Less family support for exercise and lower self-efficacy for exercise were significantly related to greater leisure-time physical activity barriers during pregnancy for previously inactive women. Lower self-efficacy for exercise, higher depressed mood scores, and younger age were associated with greater leisure-time physical activity barriers for active women. Findings suggest that the intensities of perceived leisure-time physical activity benefits and barriers during pregnancy differ for women, depending on their pre-pregnancy leisure-time physical activity status. Consideration of pre-pregnancy leisure-time physical activity status may thus be important when tailoring strategies to overcome barriers to promote initiation and maintenance of physical activity during pregnancy.

  5. Correlates of postpartum depression in first time mothers without previous psychiatric contact.

    Science.gov (United States)

    Sylvén, S M; Thomopoulos, T P; Kollia, N; Jonsson, M; Skalkidou, A

    2017-02-01

    Postpartum depression (PPD) is a common disorder after childbirth. The strongest known predictors are a history of depression and/or a history of PPD. However, for a significant proportion of women, PPD constitutes their first depressive episode. This study aimed to gain further insight into the risk factors for PPD in first time mothers without previous psychiatric contact. Women delivering in Uppsala University Hospital, Sweden, from May 2006 to June 2007, were asked to participate and filled out questionnaires five days and six weeks postpartum, containing inter alia the Edinburgh Postnatal Depression Scale (EPDS). Univariate logistic regression models, as well as a path analysis, were performed to unveil the complex interplay between the study variables. Of the 653 participating primiparas, 10.3% and 6.4% reported depressive symptoms (EPDS≥12 points) five days and six weeks postpartum, respectively. In the path analysis, a positive association between anxiety proneness and depressive symptoms at five days and six weeks postpartum was identified. For depressive symptoms six weeks after delivery, additional risk factors were detected, namely depressive symptoms five days postpartum and subjective experience of problems with the baby. Caesarean section and assisted vaginal delivery were associated with fewer depressive symptoms at 6 six weeks postpartum. Identification of anxiety proneness, delivery mode and problems with the baby as risk factors for self-reported depressive symptoms postpartum in this group of primiparas can be important in helping health care professionals identify women at increased risk of affective disorders in the perinatal period, and provide a base for early intervention. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Detection of previously undiagnosed cases of COPD in a high-risk population identified in general practice

    DEFF Research Database (Denmark)

    Løkke, Anders; Ulrik, Charlotte Suppli; Dahl, Ronald

    2012-01-01

    Background and Aim: Under-diagnosis of COPD is a widespread problem. This study aimed to identify previously undiagnosed cases of COPD in a high-risk population identified through general practice. Methods: Participating GPs (n = 241) recruited subjects with no previous diagnosis of lung disease,...

  7. All-passive pixel super-resolution of time-stretch imaging

    Science.gov (United States)

    Chan, Antony C. S.; Ng, Ho-Cheung; Bogaraju, Sharat C. V.; So, Hayden K. H.; Lam, Edmund Y.; Tsia, Kevin K.

    2017-03-01

    Based on image encoding in a serial-temporal format, optical time-stretch imaging entails a stringent requirement of state-of-the-art fast data acquisition unit in order to preserve high image resolution at an ultrahigh frame rate — hampering the widespread utilities of such technology. Here, we propose a pixel super-resolution (pixel-SR) technique tailored for time-stretch imaging that preserves pixel resolution at a relaxed sampling rate. It harnesses the subpixel shifts between image frames inherently introduced by asynchronous digital sampling of the continuous time-stretch imaging process. Precise pixel registration is thus accomplished without any active opto-mechanical subpixel-shift control or other additional hardware. Here, we present the experimental pixel-SR image reconstruction pipeline that restores high-resolution time-stretch images of microparticles and biological cells (phytoplankton) at a relaxed sampling rate (≈2-5 GSa/s)—more than four times lower than the originally required readout rate (20 GSa/s) — is thus effective for high-throughput label-free, morphology-based cellular classification down to single-cell precision. Upon integration with the high-throughput image processing technology, this pixel-SR time-stretch imaging technique represents a cost-effective and practical solution for large scale cell-based phenotypic screening in biomedical diagnosis and machine vision for quality control in manufacturing.

  8. Impact of previous extended and daily wear schedules on signs and symptoms with high Dk lotrafilcon A lenses.

    Science.gov (United States)

    Chalmers, Robin L; Dillehay, Sally; Long, Bill; Barr, Joseph T; Bergenske, Peter; Donshik, Peter; Secor, Glenda; Yoakum, John

    2005-06-01

    This study measured the impact of previous contact lens wearing schedule on the resolution of signs and contact lens-related symptoms among wearers of lotrafilcon A lenses. One hundred forty adapted low Dk daily wear (DW) and 140 adapted low Dk extended wear (EW) subjects were enrolled and examined for 1 year (overall study length is 3 years). All subjects wore lotrafilcon A lenses on a wearing schedule of up to 30 nights continuous wear with monthly replacement of lenses. Examinations were conducted at 1 week, 1, 6, and 12 months. The former EW wearers presented at baseline with significantly higher conjunctival staining and epithelial microcysts (p Dk DW and EW wearers within 1 week as did severity of dryness during the day for the former DW wearers, in part as a result of their higher prevalence at baseline in the DW group. Subjects reported redness improved significantly by the 1-month visit. Continuous wear of high Dk silicone hydrogel lenses resulted in an improvement in ocular redness and neovascularization and dryness symptoms among subjects in this trial, regardless of their previous low Dk lens-wearing schedule. All improvements in signs and symptoms were sustained through 12 months.

  9. Real-time all-optical OFDM transmission system based on time-domain optical fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Kong, Deming; Røge, Kasper Meldgaard

    2014-01-01

    We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km....

  10. High-Grade Leiomyosarcoma Arising in a Previously Replanted Limb

    Directory of Open Access Journals (Sweden)

    Tiffany J. Pan

    2015-01-01

    Full Text Available Sarcoma development has been associated with genetics, irradiation, viral infections, and immunodeficiency. Reports of sarcomas arising in the setting of prior trauma, as in burn scars or fracture sites, are rare. We report a case of a leiomyosarcoma arising in an arm that had previously been replanted at the level of the elbow joint following traumatic amputation when the patient was eight years old. He presented twenty-four years later with a 10.8 cm mass in the replanted arm located on the volar forearm. The tumor was completely resected and pathology examination showed a high-grade, subfascial spindle cell sarcoma diagnosed as a grade 3 leiomyosarcoma with stage pT2bNxMx. The patient underwent treatment with brachytherapy, reconstruction with a free flap, and subsequently chemotherapy. To the best of our knowledge, this is the first case report of leiomyosarcoma developing in a replanted extremity. Development of leiomyosarcoma in this case could be related to revascularization, scar formation, or chronic injury after replantation. The patient remains healthy without signs of recurrence at three-year follow-up.

  11. Thyroid abnormalities in patients previously treated with irradiation for acne vulgaris

    International Nuclear Information System (INIS)

    Thomson, D.B.; Grammes, C.F.; Starkey, R.H.; Monsaert, R.P.; Sunderlin, F.S.

    1984-01-01

    Of 1203 patients who received radiation treatment for acne vulgaris between 1940 and 1968, 302 were recalled and examined, 121 at Geisinger Medical Center and the remainder by their local physicians. Radiation records were reviewed on all patients. Lead-rubber and cones had been used as shielding. Mean age at the time of exposure was 21 years and mean total exposure was 692 R. Palpable nodular thyroid disease was found in eight patients (2.6%). Of these, thyroid carcinoma was detected in two patients (0.66%). Although the number of patients examined was small, the incidence of carcinomas was unexpectedly high. The authors conclude that follow-up examination is worthwhile for patients previously treated by irradiation for acne vulgaris

  12. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  13. Human Intelligence: All Humans, All Minds, All the Time

    Science.gov (United States)

    2010-05-01

    Times, June 4, 2009, p. 1. 106. Norman Polmar and Thomas Allen, Merchants of Trea- son: America’s Secrets for Sale, New York: Dell , 1989. 107. Stuart...the eight chal- lengers (Brazil, China, India, Indonesia, Iran, Russia, Venezuela, and Wild Cards such as Congo, Malaysia , and Turkey) is if we

  14. Stability of The Synchronization Manifold in An All-To-All Time LAG- Diffusively Coupled Oscillators

    Directory of Open Access Journals (Sweden)

    Adu A.M. Wasike

    2009-06-01

    Full Text Available we consider a lattice system of identical oscillators that are all coupled to one another with a diffusive coupling that has a time lag. We use the natural splitting of the system into synchronized manifold and transversal manifold to estimate the value of the time lag for which the stability of the system follows from that without a time lag. Each oscillator has a unique periodic solution that is attracting.

  15. Minimum Cycle Basis and All-Pairs Min Cut of a Planar Graph in Subquadratic Time

    DEFF Research Database (Denmark)

    Wulff-Nilsen, Christian

    2009-01-01

    equivalent to the minimum cycle basis problem for planar graphs. We also obtain O(n3/2 log n) time and O(n3/2) space algorithms for finding, respectively, the weight vector and a Gomory-Hu tree of G. The previous best time and space bound for these two problems was quadratic. From our Gomory-Hu tree...... show that this is optimal if an explicit represen- tation of the basis is required. We then present an O(n3/2 log n) time and O(n3/2) space algorithm that computes a minimum cycle basis implicitly. From this result, we obtain an output-sensitive algorithm that explicitly computes a minimum cycle basis...... in O(n3/2 log n + C) time and O(n3/2 + C) space, where C is the total size (number of edges and vertices) of the cycles in the basis. These bounds reduce to O(n3/2 log n) and O(n3/2), respectively, when G is unweighted. We get similar results for the all-pairs min cut problem since it is dual...

  16. Clinical outcomes of Laparoscopically Assisted Vaginal Hysterectomy at patients who had previous abdominopelvic surgery

    Directory of Open Access Journals (Sweden)

    Ali Riza Odabasi

    2007-03-01

    Full Text Available OBJECTIVE: To determine clinical outcomes of Laparoscopically Assisted Vaginal Hysterectomy (LAVH at patients who had previous abdominopelvic surgery.\tDesign: A clinical observational, prospective, non randomised trial comparing outcomes of 13 patients who had previous abdominopelvic surgery with outcomes of 19 patients who had not surgery.\tSetting: Adnan Menderes University Faculty of Medicine, Department of Obstetrics and Gynecology.\tPatients: Thirty-two subjects [average age 51,1±6,9 (37-66] who had indication of total abdominal hysterectomy and bilateral\tsalpingooferectomy due to benign pathologies.\tInterventions: According to ACOG, LAVH was performed by using the Garry technique at the trocar insertions, the Reich technique\tat the laparoscopic phase and the Heaney technique at the vaginal phase by the same operator. After adhesiolysis and diagnostic procedures, ureters were dissected medially. By coagulating, bilateral round and infundibulopelvic ligaments were cut after the\tmobilisation of bladder. The operation was completed by the same operation team by vaginal approach consequently. At all operations, 80 W unipolar or 150 W bipolar diathermic dissection and 25-35 W unipolar diathermic cutting were performed.\tMain outcome measures: Age, parity, menopausal status, preoperative indications, type of previous abdominopelvic surgey and incision, intraoperative indications, adhesion scores, rate of unintended laparotomy, operative time, uterus weight, loss of blood,\tcomplications, postoperative pain scores and analgesic requirements, time necessary for returning to normal intestinal function, length of hospitalisation and rate of readmission to hospital.\tRESULTS: When compared with the patients who had not previous abdominopelvic surgery, all adhesion scores, uterus weight, operative time and the number of total postoperative complications were found significantly high at patients who had previous\tsurgery. Loss of blood, the rate

  17. A simple exposure-time theory for all time-nonlocal transport formulations and beyond.

    Science.gov (United States)

    Ginn, T. R.; Schreyer, L. G.

    2016-12-01

    Anomalous transport or better put, anomalous non-transport, of solutes or flowing water or suspended colloids or bacteria etc. has been the subject of intense analyses with multiple formulations appearing in scientific literature from hydrology to geomorphology to chemical engineering, to environmental microbiology to mathematical physics. Primary focus has recently been on time-nonlocal mass conservation formulations such as multirate mass transfer, fractional-time advection-dispersion, continuous-time random walks, and dual porosity modeling approaches, that employ a convolution with a memory function to reflect respective conceptual models of delays in transport. These approaches are effective or "proxy" ones that do not always distinguish transport from immobilzation delays, are generally without connection to measurable physicochemical properties, and involve variously fractional calculus, inverse Laplace or Fourier transformations, and/or complex stochastic notions including assumptions of stationarity or ergodicity at the observation scale. Here we show a much simpler approach to time-nonlocal (non-)transport that is free of all these things, and is based on expressing the memory function in terms of a rate of mobilization of immobilized mass that is a function of the continguous time immobilized. Our approach treats mass transfer completely independently from the transport process, and it allows specification of actual immobilization mechanisms or delays. To our surprize we found that for all practical purposes any memory function can be expressed this way, including all of those associated with the multi-rate mass transfer approaches, original powerlaw, different truncated powerlaws, fractional-derivative, etc. More intriguing is the fact that the exposure-time approach can be used to construct heretofore unseen memory functions, e.g., forms that generate oscillating tails of breakthrough curves such as may occur in sediment transport, forms for delay

  18. A multi-channel high-resolution time recorder system

    International Nuclear Information System (INIS)

    Zhang Lingyun; Yang Xiaojun; Song Kezhu; Wang Yanfang

    2004-01-01

    This paper introduces a multi-channel and high-speed time recorder system, which was originally designed to work in the experiments of quantum cryptography research. The novelty of the system is that all the hardware logic is performed by only one FPGA. The system can achieve several desirable features, such as simplicity, high resolution and high processing speed. (authors)

  19. A compact, all solid-state LC high voltage generator.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2013-06-01

    LC generator is widely applied in the field of high voltage generation technology. A compact and all solid-state LC high voltage generator based on saturable pulse transformer is proposed in this paper. First, working principle of the generator is presented. Theoretical analysis and circuit simulation are used to verify the design of the generator. Experimental studies of the proposed LC generator with two-stage main energy storage capacitors are carried out. And the results show that the proposed LC generator operates as expected. When the isolation inductance is 27 μH, the output voltage is 1.9 times larger than the charging voltage on single capacitor. The multiplication of voltages is achieved. On the condition that the primary energy storage capacitor is charged to 857 V, the output voltage of the generator can reach to 59.5 kV. The step-up ratio is nearly 69. When self breakdown gas gap switch is used as main switch, the rise time of the voltage pulse on load resistor is 8.7 ns. It means that the series-wound inductance in the discharging circuit is very small in this system. This generator can be employed in two different applications.

  20. Leisure-time running reduces all-cause and cardiovascular mortality risk.

    Science.gov (United States)

    Lee, Duck-Chul; Pate, Russell R; Lavie, Carl J; Sui, Xuemei; Church, Timothy S; Blair, Steven N

    2014-08-05

    Although running is a popular leisure-time physical activity, little is known about the long-term effects of running on mortality. The dose-response relations between running, as well as the change in running behaviors over time, and mortality remain uncertain. We examined the associations of running with all-cause and cardiovascular mortality risks in 55,137 adults, 18 to 100 years of age (mean age 44 years). Running was assessed on a medical history questionnaire by leisure-time activity. During a mean follow-up of 15 years, 3,413 all-cause and 1,217 cardiovascular deaths occurred. Approximately 24% of adults participated in running in this population. Compared with nonrunners, runners had 30% and 45% lower adjusted risks of all-cause and cardiovascular mortality, respectively, with a 3-year life expectancy benefit. In dose-response analyses, the mortality benefits in runners were similar across quintiles of running time, distance, frequency, amount, and speed, compared with nonrunners. Weekly running even benefits, with 29% and 50% lower risks of all-cause and cardiovascular mortality, respectively, compared with never-runners. Running, even 5 to 10 min/day and at slow speeds benefits. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Thyroid abnormalities in patients previously treated with irradiation for acne vulgaris

    International Nuclear Information System (INIS)

    Thomson, D.B.; Grammes, C.F.; Starkey, R.H.; Monsaert, R.P.; Sunderlin, F.S.

    1984-01-01

    Of 1,203 patients who received radiation treatment for acne vulgaris between 1940 and 1968, 302 patients were recalled and examined, 121 at Geisinger Medical Center and the remainder by their local physicians. Radiation records were reviewed on all patients. Lead-rubber and cones had been used as shielding. Mean age at the time of exposure was 21 years and mean total exposure was 692 R. Palpable nodular thyroid disease was found in eight patients (2.6%). Of these, thyroid carcinoma was detected in two patients (0.66%). Although the number of patients examined was small, the incidence of carcinomas was unexpectedly high. We conclude that follow-up examination is worthwhile for patients previously treated by irradiation for acne vulgaris

  2. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  3. Dispersal of antibiotic-resistant high-risk clones by hospital networks : changing the patient direction can make all the difference

    NARCIS (Netherlands)

    Donker, T.; Wallinga, J.; Grundmann, H.

    Background: Patients who seek treatment in hospitals can introduce high-risk clones of hospital-acquired, antibiotic-resistant pathogens from previous admissions. In this manner, different healthcare institutions become linked epidemiologically. All links combined form the national patient referral

  4. High time resolution measurements of the thermosphere from Fabry-Perot Interferometer measurements of atomic oxygen

    Directory of Open Access Journals (Sweden)

    E. A. K. Ford

    2007-06-01

    Full Text Available Recent advances in the performance of CCD detectors have enabled a high time resolution study of the high latitude upper thermosphere with Fabry-Perot Interferometers (FPIs to be performed. 10-s integration times were used during a campaign in April 2004 on an FPI located in northern Sweden in the auroral oval. The FPI is used to study the thermosphere by measuring the oxygen red line emission at 630.0 nm, which emits at an altitude of approximately 240 km. Previous time resolutions have been 4 min at best, due to the cycle of look directions normally observed. By using 10 s rather than 40 s integration times, and by limiting the number of full cycles in a night, high resolution measurements down to 15 s were achievable. This has allowed the maximum variability of the thermospheric winds and temperatures, and 630.0 nm emission intensities, at approximately 240 km, to be determined as a few minutes. This is a significantly greater variability than the often assumed value of 1 h or more. A Lomb-Scargle analysis of this data has shown evidence of gravity wave activity with waves with short periods. Gravity waves are an important feature of mesosphere-lower thermosphere (MLT dynamics, observed using many techniques and providing an important mechanism for energy transfer between atmospheric regions. At high latitudes gravity waves may be generated in-situ by localised auroral activity. Short period waves were detected in all four clear nights when this experiment was performed, in 630.0 nm intensities and thermospheric winds and temperatures. Waves with many periodicities were observed, from periods of several hours, down to 14 min. These waves were seen in all parameters over several nights, implying that this variability is a typical property of the thermosphere.

  5. All-IP wireless sensor networks for real-time patient monitoring.

    Science.gov (United States)

    Wang, Xiaonan; Le, Deguang; Cheng, Hongbin; Xie, Conghua

    2014-12-01

    This paper proposes the all-IP WSNs (wireless sensor networks) for real-time patient monitoring. In this paper, the all-IP WSN architecture based on gateway trees is proposed and the hierarchical address structure is presented. Based on this architecture, the all-IP WSN can perform routing without route discovery. Moreover, a mobile node is always identified by a home address and it does not need to be configured with a care-of address during the mobility process, so the communication disruption caused by the address change is avoided. Through the proposed scheme, a physician can monitor the vital signs of a patient at any time and at any places, and according to the IPv6 address he can also obtain the location information of the patient in order to perform effective and timely treatment. Finally, the proposed scheme is evaluated based on the simulation, and the simulation data indicate that the proposed scheme might effectively reduce the communication delay and control cost, and lower the packet loss rate. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. High power all solid state VUV lasers

    International Nuclear Information System (INIS)

    Zhang, Shen-jin; Cui, Da-fu; Zhang, Feng-feng; Xu, Zhi; Wang, Zhi-min; Yang, Feng; Zong, Nan; Tu, Wei; Chen, Ying; Xu, Hong-yan; Xu, Feng-liang; Peng, Qin-jun; Wang, Xiao-yang; Chen, Chuang-tian; Xu, Zu-yan

    2014-01-01

    Highlights: • Polarization and pulse repetition rate adjustable ps 177.3 nm laser was developed. • Wavelength tunable ns, ps and fs VUV lasers were developed. • High power ns 177.3 nm laser with narrow linewidth was investigated. - Abstract: We report the investigation on the high power all solid state vacuum ultra-violet (VUV) lasers by means of nonlinear frequency conversion with KBe 2 BO 3 F 2 (KBBF) nonlinear crystal. Several all solid state VUV lasers have developed in our group, including polarization and pulse repetition rate adjustable picosecond 177.3 nm VUV laser, wavelength tunable nanosecond, picosecond and femtosecond VUV lasers, high power ns 177.3 nm laser with narrow linewidth. The VUV lasers have impact, accurate and precise advantage

  7. Ceramic high-rate timing RPCs

    International Nuclear Information System (INIS)

    Lopes, L.; Ferreira Marques, R.; Fonte, P.; Hennetier, L.; Pereira, A.; Sousa Correia, A.M.

    2006-01-01

    Following some previous work, we report here considerable improvements on the counting rate capability of timing RPCs by the use of ceramic electrodes with a resistivity of 10 9 Ω.cm. The X-ray sensitivity of the detector depends linearly on the counting rate with a slope of 9% per 100 kHz/cm 2 , free from charge depletion effects, while keeping a timing accuracy, measured with 511 keV synchronous photon pairs, around 90 ps σ up to 75 kHz/cm 2

  8. High resolution time integration for SN radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2009-01-01

    First-order, second-order, and high resolution time discretization schemes are implemented and studied for the discrete ordinates (S N ) equations. The high resolution method employs a rate of convergence better than first-order, but also suppresses artificial oscillations introduced by second-order schemes in hyperbolic partial differential equations. The high resolution method achieves these properties by nonlinearly adapting the time stencil to use a first-order method in regions where oscillations could be created. We employ a quasi-linear solution scheme to solve the nonlinear equations that arise from the high resolution method. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second-order and high resolution converged to the same solution as the first-order with better convergence rates. High resolution is more accurate than first-order and matches or exceeds the second-order method

  9. High frequency, high time resolution time-to-digital converter employing passive resonating circuits.

    Science.gov (United States)

    Ripamonti, Giancarlo; Abba, Andrea; Geraci, Angelo

    2010-05-01

    A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

  10. High frequency, high time resolution time-to-digital converter employing passive resonating circuits

    International Nuclear Information System (INIS)

    Ripamonti, Giancarlo; Abba, Andrea; Geraci, Angelo

    2010-01-01

    A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

  11. Squamous cell carcinoma arising in previously burned or irradiated skin

    International Nuclear Information System (INIS)

    Edwards, M.J.; Hirsch, R.M.; Broadwater, J.R.; Netscher, D.T.; Ames, F.C.

    1989-01-01

    Squamous cell carcinoma (SCC) arising in previously burned or irradiated skin was reviewed in 66 patients treated between 1944 and 1986. Healing of the initial injury was complicated in 70% of patients. Mean interval from initial injury to diagnosis of SCC was 37 years. The overwhelming majority of patients presented with a chronic intractable ulcer in previously injured skin. The regional relapse rate after surgical excision was very high, 58% of all patients. Predominant patterns of recurrence were in local skin and regional lymph nodes (93% of recurrences). Survival rates at 5, 10, and 20 years were 52%, 34%, and 23%, respectively. Five-year survival rates in previously burned and irradiated patients were not significantly different (53% and 50%, respectively). This review, one of the largest reported series, better defines SCC arising in previously burned or irradiated skin as a locally aggressive disease that is distinct from SCC arising in sunlight-damaged skin. An increased awareness of the significance of chronic ulceration in scar tissue may allow earlier diagnosis. Regional disease control and survival depend on surgical resection of all known disease and may require radical lymph node dissection or amputation

  12. Generation of real-time mode high-resolution water vapor fields from GPS observations

    Science.gov (United States)

    Yu, Chen; Penna, Nigel T.; Li, Zhenhong

    2017-02-01

    Pointwise GPS measurements of tropospheric zenith total delay can be interpolated to provide high-resolution water vapor maps which may be used for correcting synthetic aperture radar images, for numeral weather prediction, and for correcting Network Real-time Kinematic GPS observations. Several previous studies have addressed the importance of the elevation dependency of water vapor, but it is often a challenge to separate elevation-dependent tropospheric delays from turbulent components. In this paper, we present an iterative tropospheric decomposition interpolation model that decouples the elevation and turbulent tropospheric delay components. For a 150 km × 150 km California study region, we estimate real-time mode zenith total delays at 41 GPS stations over 1 year by using the precise point positioning technique and demonstrate that the decoupled interpolation model generates improved high-resolution tropospheric delay maps compared with previous tropospheric turbulence- and elevation-dependent models. Cross validation of the GPS zenith total delays yields an RMS error of 4.6 mm with the decoupled interpolation model, compared with 8.4 mm with the previous model. On converting the GPS zenith wet delays to precipitable water vapor and interpolating to 1 km grid cells across the region, validations with the Moderate Resolution Imaging Spectroradiometer near-IR water vapor product show 1.7 mm RMS differences by using the decoupled model, compared with 2.0 mm for the previous interpolation model. Such results are obtained without differencing the tropospheric delays or water vapor estimates in time or space, while the errors are similar over flat and mountainous terrains, as well as for both inland and coastal areas.

  13. TODOS LOS TIEMPO / All times

    Directory of Open Access Journals (Sweden)

    Juan José López de la Cruz

    2010-05-01

    áneamente, permitiría la posibilidad de atender desde el proyecto de arquitectura a alteraciones futuras, a momentos por venir de nuestros proyectos que asuman los procesos de cambio y deterioro como parte de nuestra cultura y observen su huella como un modo de transmisión de la misma, entendiendo que un mundo sin degradación sería quizá un mundo sin memoria. En este cuarto número de PPA hemos querido reflexionar en torno a discursos e intervenciones que han emprendido caminos intermedios que transitan entre estos tiempos, a veces ficticios, que descartan la drástica demolición que cercena cualquier atisbo de una vida pasada y la recuperación material empeñada en congelar la arquitectura en un momento que quizá sólo fue un instante en la vida del edificio no más real que otros que quedaron ocultos. Los distintos artículos reunidos en esta publicación coinciden en mostrar la arquitectura, desde la formulación de estrategias, visiones retrospectivas o intervenciones concretas, en su antigua condición de permanencia a la vez que asumen la alteración como posibilidad de repensar lo existente, en descubrir alternativas no ensayadas que habitan latentes en nuestro mundo o en desvelar caminos disyuntivos que quedaron ocultos por otros que prevalecieron y que pueden ser retomados en momentos futuros. SUMMARY Intervention on the architecture of the past is no more than a particular case of a universal conception of the transformation processes incumbent on all architectural design. We might think that architectural action is always an alteration of our existing world, so that to plan is only to rethink it again and again, a fabulous attempt to continually transform reality, constructed or figurative, to adapt it to the variable of our constantly changing thinking. This mode of approach to the architectural project as an alteration of a continuous reality, standing before and after the project, sees time as a theme of research and reflection. The project therefore becomes the

  14. High Times: The Effect of Medical Marijuana Laws on Student Time Use

    OpenAIRE

    Chu, Yu-Wei Luke; Gershenson, Seth

    2016-01-01

    Twenty-three states and the District of Columbia have passed medical marijuana laws. Previous research shows that these laws increase marijuana use among adults. In this paper, we estimate the effects of medical marijuana laws (MML) on secondary and post-secondary students' time use using time diaries from the American Time Use Survey. We apply a difference-in-differences research design and estimate flexible fixed effects models that condition on state fixed effects and state-specific time t...

  15. Real-time magnetic resonance imaging of highly dynamic granular phenomena

    Science.gov (United States)

    Penn, Alexander; Pruessmann, Klaas P.; Müller, Christoph

    Probing non-intrusively the interior of three-dimensional granular systems is a challenging task for which a number of imaging techniques have been applied including positron emission particle tracking, X-ray tomography and magnetic resonance imaging (MRI). A particular advantage of MRI is its versatility allowing quantitative velocimetry through phase contrast encoding and tagging, arbitrary slice orientations and the flexibility to trade spatial for temporal resolution and vice versa during image reconstruction. However, previous attempts to image granular systems using MRI were often limited to (pseudo-) steady state systems due to the poor temporal resolution of conventional imaging methodology. Here we present an experimental approach that overcomes previous limitations in temporal resolution by implementing a variety of methodological advances, viz. parallel data acquisition through tailored multiple receiver coils, fast gradient readouts for time-efficient data sampling and engineered granular materials that contain signal sources of high proton density. Achieving a spatial and temporal resolution of, respectively, 2 mm x 2 mm and 50 ms, we were able to image highly dynamic phenomena in granular media such as bubble coalescence and granular compaction waves.

  16. A new all-sky map of Galactic high-velocity clouds from the 21-cm HI4PI survey

    Science.gov (United States)

    Westmeier, Tobias

    2018-02-01

    High-velocity clouds (HVCs) are neutral or ionized gas clouds in the vicinity of the Milky Way that are characterized by high radial velocities inconsistent with participation in the regular rotation of the Galactic disc. Previous attempts to create a homogeneous all-sky H I map of HVCs have been hampered by a combination of poor angular resolution, limited surface brightness sensitivity and suboptimal sampling. Here, a new and improved H I map of Galactic HVCs based on the all-sky HI4PI survey is presented. The new map is fully sampled and provides significantly better angular resolution (16.2 versus 36 arcmin) and column density sensitivity (2.3 versus 3.7 × 1018 cm-2 at the native resolution) than the previously available LAB survey. The new HVC map resolves many of the major HVC complexes in the sky into an intricate network of narrow H I filaments and clumps that were not previously resolved by the LAB survey. The resulting sky coverage fraction of high-velocity H I emission above a column density level of 2 × 1018 cm-2 is approximately 15 per cent, which reduces to about 13 per cent when the Magellanic Clouds and other non-HVC emission are removed. The differential sky coverage fraction as a function of column density obeys a truncated power law with an exponent of -0.93 and a turnover point at about 5 × 1019 cm-2. H I column density and velocity maps of the HVC sky are made publicly available as FITS images for scientific use by the community.

  17. Universal time dependence of nighttime F region densities at high latitudes

    International Nuclear Information System (INIS)

    Beaujardiere, O.D.L.; Wickwar, V.B.; Caudal, G.

    1985-01-01

    Coordinated EISCAT, Chatanika, and Millstone Hill incoherent scatter radar observations have revealed that in the auroral zone, the nighttime F region densities vary substantially with the longitude of the observing site: EISCAT's densities are the largest and Millstone Hill's are the lowest. The nighttime F region densities measured by the individual radars are not uniform: the regions where the densities are maximum are the so-called ''blobs'' or ''patches'' that have been reported previously. The observations are consistent with the hypothesis that the nighttime densities are produced in significant amounts not by particle precipitation, but by solar EUV radiation, and that they have been transported across the polar cap. The observed differences can be explained by the offset of the geographic and geomagnetic poles. A larger portion of the magnetospheric convection pattern is sunlit when EISCAT is in the midnight sector than when Chatanika is. In winter, when Millstone Hill is in the midnight sector, almost all the auroral oval is in darkness. This universal time effect, which was observed on all coordinated three-radar experiments (September 1981 to February 1982), is illustrated using two periods of coincident radar and satellite observations: November 18--19, and December 15--16, 1981. These two periods were selected because they corresponded to relatively steady conditions. Dynamics Explorer (DE) measurements are used to aid in interpreting the radar observations. De 1 auroral images show what portion of the oval was sunlit. DE 2 data are used to measure the ion drift across the polar cap. Because the altitude of the ionization peak was high, the decay time of the F region density was substantially longer than the transit time across the polar cap

  18. Second malignancies in high-dose areas of previous tumor radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Welte, Birgitta; Suhr, Peter; Bottke, Dirk; Bartkowiak, Detlef; Wiegel, Thomas [Dept. of Radiotherapy and Radiation Oncology, Univ. of Ulm (Germany); Doerr, Wolfgang [Dept. of Radiotherapy and Radiation Oncology, Radiobiology Lab., Univ. of Technology Dresden (Germany); Trott, Klaus Ruediger [UCL Cancer Centre, Univ. Coll. London (United Kingdom)

    2010-03-15

    Purpose: To characterize second tumors that developed in or near the high-dose areas of a previous radiotherapy, regarding their frequency, entities, latency, and dose dependence. Patients and Methods: 9,995/15,449 tumor patients of the Radiation Oncology Department in Ulm, Germany, treated between 1981 and 2003, survived at least 1 year after radiotherapy. By long-term follow-up and review of treatment documentation, 100 of them were identified who developed an independent second cancer in or near the irradiated first tumor site. Results: Major primary malignancies were breast cancer (27%), lymphoma (24%), and pelvic gynecologic tumors (17%). Main second tumors were carcinomas of the upper (18%) and lower (12%) gastrointestinal tract, head and neck tumors (10%), lymphoma (10%), breast cancer (9%), sarcoma (9%), and lung cancer (8%). Overall median second tumor latency was 7.4 years (1-42 years). For colorectal cancer it was 3.5 and for leukemia 4.3 years, but for sarcoma 11.7 and for breast cancer 17.1 years. The relatively frequent second tumors of the upper gastrointestinal tract were associated with median radiation doses of 24 Gy. By contrast, second colorectal cancer and sarcoma developed after median doses of 50 Gy. Conclusion: The 5- and 15-year probability to develop a histopathologically independent second tumor in or near the irradiated first tumor site, i.e., after intermediate or high radiation doses, was 0.5% and 2.2%, respectively. To identify potentially radiogenic second malignancies, a follow-up far beyond 5 years is mandatory. The incidence and potential dose-response relationship intermediate will be analyzed by a case-case and a case-control study of the Ulm data. (orig.)

  19. The Relationship Between Functional Movement, Balance Deficits, and Previous Injury History in Deploying Marine Warfighters.

    Science.gov (United States)

    de la Motte, Sarah J; Lisman, Peter; Sabatino, Marc; Beutler, Anthony I; OʼConnor, Francis G; Deuster, Patricia A

    2016-06-01

    Screening for primary musculoskeletal injury (MSK-I) is costly and time-consuming. Both the Functional Movement Screen (FMS) and the Y-Balance Test (YBT) have been shown to predict future MSK-I. With a goal of optimizing the efficiency of primary MSK-I screening, we studied associations between performance on the FMS and YBT and whether history of MSK-I influenced FMS and YBT scores. In total, 365 deploying Marines performed the FMS and YBT as prescribed. Composite and individual scores were each categorized as high risk or low risk using published injury thresholds: High-risk FMS included composite scores ≤14 and right-to-left (R/L) asymmetry for Shoulder Mobility, In-Line Lunge, Straight Leg Raise, Hurdle Step, or Rotary Stability. High-risk YBT consisted of anterior, posteromedial, and/or posterolateral R/L differences >4 cm and/or composite differences ≥12 cm. Pearson's χ tests evaluated associations between: (a) all FMS and YBT risk groups and (b) previous MSK-I and all FMS and YBT risk groups. Marines with high-risk FMS were twice as likely to have high-risk YBT posteromedial scores (χ = 10.2, p = 0.001; odds ratio [OR] = 2.1, 95% confidence interval [CI] = 1.3-3.2). History of any MSK-I was not associated with high-risk FMS or high-risk YBT. However, previous lower extremity MSK-I was associated with In-Line Lunge asymmetries (χ = 9.8, p = 0.002, OR = 2.2, 95% CI = 1.3-3.6). Overall, we found limited overlap in FMS and YBT risk. Because both methods seem to assess different risk factors for injury, we recommend FMS and YBT continue to be used together in combination with a thorough injury history until their predictive capacities are further established.

  20. High precision timing in a FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Hoek, Matthias; Cardinali, Matteo; Dickescheid, Michael; Schlimme, Soeren; Sfienti, Concettina; Spruck, Bjoern; Thiel, Michaela [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet Mainz (Germany)

    2016-07-01

    A segmented highly precise start counter (FLASH) was designed and constructed at the Institute for Nuclear Physics in Mainz. Besides determining a precise reference time, a Time-of-Flight measurement can be performed with two identical FLASH units. Thus, particle identification can be provided for mixed hadron beam environments. The detector design is based on the detection of Cherenkov light produced in fused silica radiator bars with fast multi-anode MCP-PMTs. The segmentation of the radiator improves the timing resolution while allowing a coarse position resolution along one direction. Both, the arrival time and the Time-over-Threshold are determined by the readout electronics, which enables walk correction of the arrival time. The performance of two FLASH units was investigated in test experiments at the Mainz Microton (MAMI) using an electron beam with an energy of 855 MeV and at CERN's PS T9 beam line with a mixed hadron beam with momenta between 3-8 GeV/c. Effective Time-walk correction methods based on Time-over-Threshold were developed for the data analysis. The achieved Time-Of-Flight resolution after applying all corrections was found to be 70 ps. Furthermore, the PID and position resolution capabilities are discussed in this contribution.

  1. Associations of objectively assessed physical activity and sedentary time with all-cause mortality in US adults: the NHANES study.

    Science.gov (United States)

    Schmid, Daniela; Ricci, Cristian; Leitzmann, Michael F

    2015-01-01

    Sedentary behavior is related to increased mortality risk. Whether such elevated risk can be offset by enhanced physical activity has not been examined using accelerometry data. We examined the relations of sedentary time and physical activity to mortality from any cause using accelerometry data among 1,677 women and men aged 50 years or older from the National Health and Nutrition Examination Survey (NHANES) 2003-2004 cycle with follow-up through December 31, 2006. During an average follow-up of 34.67 months and 4,845.42 person-years, 112 deaths occurred. In multivariate Cox proportional hazard models, greater sedentary time (≥ median of 8.60 hours/day) was associated with increased risk of mortality from any cause (relative risk (RR) = 2.03; 95% confidence interval (CI) = 1.09-3.81). Low level of moderate to vigorous physical activity (physical activity predicted a substantially elevated all-cause mortality risk. As compared with the combination of a low sedentary level and a high level of moderate to vigorous physical activity, the risks of mortality from all causes were 4.38 (95% CI = 1.26-15.16) for low levels of both sedentary time and physical activity, 2.79 (95% CI = 0.77-10.12) for greater time spent sedentary and high physical activity level, and 7.79 (95% CI = 2.26-26.82) for greater time spent sedentary and low physical activity level. The interaction term between sedentary time and moderate to vigorous physical activity was not statistically significant (p = 0.508). Both high levels of sedentary time and low levels of moderate to vigorous physical activity are strong and independent predictors of early death from any cause. Whether a high physical activity level removes the increased risk of all-cause mortality related to sedentariness requires further investigation.

  2. High prevalence of genetic variants previously associated with Brugada syndrome in new exome data

    DEFF Research Database (Denmark)

    Risgaard, B; Jabbari, R; Refsgaard, L

    2013-01-01

    More than 300 variants in 12 genes have been associated with Brugada syndrome (BrS) which has a prevalence ranging between 1:2000 and 1:100,000. Until recently, there has been little knowledge regarding the distribution of genetic variations in the general population. This problem was partly solved......, when exome data from the NHLI GO Exome Sequencing Project (ESP) was published. In this study, we aimed to report the prevalence of previously BrS-associated variants in the ESP population. We performed a search in ESP for variants previously associated with BrS. In addition, four variants in ESP were...... to a surprisingly high genotype prevalence of 1:23 (274:6258). Genotyping the four common ESP-derived variants CACNA2D1 S709N, SCN5A F2004L, CACNB2 S143F, and CACNB2 T450I in the Danish controls, we found a genotype prevalence comparable with that found in ESP. We suggest that exome data are used in research...

  3. Acute hepatitis B virus infection with simultaneous high HBsAg and high anti-HBs signals in a previously HBV vaccinated HIV-1 positive patient.

    Science.gov (United States)

    van Dommelen, Laura; Verbon, Annelies; van Doorn, H Rogier; Goossens, Valère J

    2010-03-01

    We present a case of a clinical manifest hepatitis B virus infection and a potentially misleading HBV serological profile in an HIV-1 positive patient despite previous HBV vaccination. The patient presented with an acute hepatitis B and there was no indication of chronic HBV infection or the presence of a mutation in the 'a' determinant. Remarkably, simultaneously with high HBV surface antigen and HBV viral load, high anti-HBs antibodies were present. If, due to previous HBV vaccination only anti-HBs was tested in this patient, the result of the high anti-HBs antibodies could be very misleading and offering a false sense of security. Our findings contribute to the ongoing discussion on how to assess HBV specific immunological memory and determining the role of HBV booster vaccinations in immunocompromised individuals.

  4. Response to health insurance by previously uninsured rural children.

    Science.gov (United States)

    Tilford, J M; Robbins, J M; Shema, S J; Farmer, F L

    1999-08-01

    To examine the healthcare utilization and costs of previously uninsured rural children. Four years of claims data from a school-based health insurance program located in the Mississippi Delta. All children who were not Medicaid-eligible or were uninsured, were eligible for limited benefits under the program. The 1987 National Medical Expenditure Survey (NMES) was used to compare utilization of services. The study represents a natural experiment in the provision of insurance benefits to a previously uninsured population. Premiums for the claims cost were set with little or no information on expected use of services. Claims from the insurer were used to form a panel data set. Mixed model logistic and linear regressions were estimated to determine the response to insurance for several categories of health services. The use of services increased over time and approached the level of utilization in the NMES. Conditional medical expenditures also increased over time. Actuarial estimates of claims cost greatly exceeded actual claims cost. The provision of a limited medical, dental, and optical benefit package cost approximately $20-$24 per member per month in claims paid. An important uncertainty in providing health insurance to previously uninsured populations is whether a pent-up demand exists for health services. Evidence of a pent-up demand for medical services was not supported in this study of rural school-age children. States considering partnerships with private insurers to implement the State Children's Health Insurance Program could lower premium costs by assembling basic data on previously uninsured children.

  5. Development of high speed integrated circuit for very high resolution timing measurements

    International Nuclear Information System (INIS)

    Mester, Christian

    2009-10-01

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  6. Development of high speed integrated circuit for very high resolution timing measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mester, Christian

    2009-10-15

    A multi-channel high-precision low-power time-to-digital converter application specific integrated circuit for high energy physics applications has been designed and implemented in a 130 nm CMOS process. To reach a target resolution of 24.4 ps, a novel delay element has been conceived. This nominal resolution has been experimentally verified with a prototype, with a minimum resolution of 19 ps. To further improve the resolution, a new interpolation scheme has been described. The ASIC has been designed to use a reference clock with the LHC bunch crossing frequency of 40 MHz and generate all required timing signals internally, to ease to use within the framework of an LHC upgrade. Special care has been taken to minimise the power consumption. (orig.)

  7. High resolution time integration for Sn radiation transport

    International Nuclear Information System (INIS)

    Thoreson, Greg; McClarren, Ryan G.; Chang, Jae H.

    2008-01-01

    First order, second order and high resolution time discretization schemes are implemented and studied for the S n equations. The high resolution method employs a rate of convergence better than first order, but also suppresses artificial oscillations introduced by second order schemes in hyperbolic differential equations. All three methods were compared for accuracy and convergence rates. For non-absorbing problems, both second order and high resolution converged to the same solution as the first order with better convergence rates. High resolution is more accurate than first order and matches or exceeds the second order method. (authors)

  8. Economic impact of feeding a phenylalanine-restricted diet to adults with previously untreated phenylketonuria.

    Science.gov (United States)

    Brown, M C; Guest, J F

    1999-02-01

    The aim of the present study was to estimate the direct healthcare cost of managing adults with previously untreated phenylketonuria (PKU) for one year before any dietary restrictions and for the first year after a phenylalanine- (PHE-) restricted diet was introduced. The resource use and corresponding costs were estimated from medical records and interviews with health care professionals experienced in caring for adults with previously untreated PKU. The mean annual cost of caring for a client being fed an unrestricted diet was estimated to be 83 996 pound silver. In the first year after introducing a PHE-restricted diet, the mean annual cost was reduced by 20 647 pound silver to 63 348 pound silver as a result of a reduction in nursing time, hospitalizations, outpatient clinic visits and medications. However, the economic benefit of the diet depended on whether the clients were previously high or low users of nursing care. Nursing time was the key cost-driver, accounting for 79% of the cost of managing high users and 31% of the management cost for low users. In contrast, the acquisition cost of a PHE-restricted diet accounted for up to 6% of the cost for managing high users and 15% of the management cost for low users. Sensitivity analyses showed that introducing a PHE-restricted diet reduces the annual cost of care, provided that annual nursing time was reduced by more than 8% or more than 5% of clients respond to the diet. The clients showed fewer negative behaviours when being fed a PHE-restricted diet, which may account for the observed reduction in nursing time needed to care for these clients. In conclusion, feeding a PHE-restricted diet to adults with previously untreated PKU leads to economic benefits to the UK's National Health Service and society in general.

  9. [Relationship between previous severity of illness and outcome of in-hospital cardiac arrest].

    Science.gov (United States)

    Serrano, M; Rodríguez, J; Espejo, A; del Olmo, R; Llanos, S; Del Castillo, J; López-Herce, J

    2014-07-01

    To analyze the relationship between previous severity of illness, lactic acid, creatinine and inotropic index with mortality of in-hospital cardiac arrest (CA) in children, and the value of a prognostic index designed for adults. The study included total of 44 children aged from 1 month to 18 years old who suffered a cardiac arrest while in hospital. The relationship between previous severity of illness scores (PRIMS and PELOD), lactic acid, creatinine, treatment with vasoactive drugs, inotropic index with return of spontaneous circulation and survival at hospital discharge was analyzed. The large majority (90.3%) of patients had a return of spontaneous circulation, and 59% survived at hospital discharge. More than two-thirds (68.2%) were treated with inotropic drugs at the time of the CA. The patients who died had a higher lactic acid before the CA (3.4 mmol/L) than survivors (1.4 mmol/L), P=.04. There were no significant differences in PRIMS, PELOD, creatinine, inotropic drugs, and inotropic index before CA between patients who died and survivors. A high lactic acid previous to cardiac arrest could be a prognostic factor of in-hospital cardiac arrest in children. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  10. Uniform Estimate of the Finite-Time Ruin Probability for All Times in a Generalized Compound Renewal Risk Model

    Directory of Open Access Journals (Sweden)

    Qingwu Gao

    2012-01-01

    Full Text Available We discuss the uniformly asymptotic estimate of the finite-time ruin probability for all times in a generalized compound renewal risk model, where the interarrival times of successive accidents and all the claim sizes caused by an accident are two sequences of random variables following a wide dependence structure. This wide dependence structure allows random variables to be either negatively dependent or positively dependent.

  11. Effect of a previous high hydrostatic pressure treatment on lipid damage in chilled Chilean jack mackerel (Trachurus murphyi

    Directory of Open Access Journals (Sweden)

    Maluenda, D.

    2013-12-01

    Full Text Available Lipid damage evolution was analyzed in chilled Chilean jack mackerel (Trachurus murphyi previously treated with high hydrostatic pressure (HHP technology. Different pressure levels and pressure holding times were tested. In addition, fish corresponding to pre- and post-rigor mortis (RM stages were comparatively studied. Previous HHP treatment led to a marked lipid hydrolysis inhibition in chilled fish. Increasing the pressure level and pressure holding time led to a lower free fatty acid content, with the effect of pressure being more relevant. According to the analysis of different types of lipid oxidation indexes, no effect of the previous HHP treatment on the lipid oxidation development could be determined in chilled jack mackerel. Concerning the effect of the RM stage of raw fish, a higher primary and secondary lipid oxidation development was observed in fish corresponding to the post-RM condition throughout the chilled storage; although a definite effect on lipid hydrolysis could not be found.Se estudió la evolución de la alteración lipídica en jurel chileno (Trachurus murphyi refrigerado previamente tratado a altas presiones hidrostáticas (HHP. Se aplicaron distintos valores de presión y tiempo de presurización; asimismo, se analizó de forma comparativa la respuesta al proceso del pescado inicial en estados pre- y post-rigor mortis (RM. El tratamiento previo por HHP produjo inhibición de la hidrólisis lipídica en pescado refrigerado, siendo más intenso el efecto de la presión que el del tiempo de presurización. De acuerdo con el análisis de distintos índices de oxidación, no se concluyó un efecto determinante sobre la oxidación lipídica por parte del tratamiento previo de HHP. En relación al efecto del estado de RM del pescado inicial, se observó una oxidación primaria y secundaria mayor en jurel correspondiente a la condición post-RM durante la conservación en refrigeración; sin embargo, no se detectó un efecto

  12. 75 FR 76056 - FEDERAL REGISTER CITATION OF PREVIOUS ANNOUNCEMENT:

    Science.gov (United States)

    2010-12-07

    ... SECURITIES AND EXCHANGE COMMISSION Sunshine Act Meeting FEDERAL REGISTER CITATION OF PREVIOUS ANNOUNCEMENT: STATUS: Closed meeting. PLACE: 100 F Street, NE., Washington, DC. DATE AND TIME OF PREVIOUSLY ANNOUNCED MEETING: Thursday, December 9, 2010 at 2 p.m. CHANGE IN THE MEETING: Time change. The closed...

  13. Real-time nanofabrication with high-speed atomic force microscopy

    International Nuclear Information System (INIS)

    Vicary, J A; Miles, M J

    2009-01-01

    The ability to follow nanoscale processes in real-time has obvious benefits for the future of material science. In particular, the ability to evaluate the success of fabrication processes in situ would be an advantage for many in the semiconductor industry. We report on the application of a previously described high-speed atomic force microscope (AFM) for nanofabrication. The specific fabrication method presented here concerns the modification of a silicon surface by locally oxidizing the region in the vicinity of the AFM tip. Oxide features were fabricated during imaging, with relative tip-sample velocities of up to 10 cm s -1 , and with a data capture rate of 15 fps.

  14. Large-scale digitizer system (LSD) for charge and time digitization in high-energy physics experiments

    International Nuclear Information System (INIS)

    Althaus, R.F.; Kirsten, F.A.; Lee, K.L.; Olson, S.R.; Wagner, L.J.; Wolverton, J.M.

    1976-10-01

    A large-scale digitizer (LSD) system for acquiring charge and time-of-arrival particle data from high-energy-physics experiments has been developed at the Lawrence Berkeley Laboratory. The objective in this development was to significantly reduce the cost of instrumenting large-detector arrays which, for the 4π-geometry of colliding-beam experiments, are proposed with an order of magnitude increase in channel count over previous detectors. In order to achieve the desired economy (approximately $65 per channel), a system was designed in which a number of control signals for conversion, for digitization, and for readout are shared in common by all the channels in each 128-channel bin. The overall-system concept and the distribution of control signals that are critical to the 10-bit charge resolution and to the 12-bit time resolution are described. Also described is the bit-serial transfer scheme, chosen for its low component and cabling costs

  15. Three-dimensional nitrogen and boron co-doped graphene for high-performance all-solid-state supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhong-Shuai; Chen, Long; Sun, Yi; Muellen, Klaus [Max-Planck-Institut fuer Polymerforschung, Ackermannweg 10, 55128 Mainz (Germany); Winter, Andreas; Turchanin, Andrey [Universitaet Bielefeld, Fakultaet fuer Physik, Physik Supramolekularer Systeme und Oberflaechen, Universitaetsstr. 25D, 33615 Bielefeld (Germany); Feng, Xinliang [Max-Planck-Institut fuer Polymerforschung, Ackermannweg 10, 55128 Mainz (Germany); School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, 200240, Shanghai (China)

    2012-09-25

    A simplified prototype device of high-performance all-solid-state supercapacitors (ASSSs) based on 3D nitrogen and boron co-doped monolithic graphene aerogels (BN-GAs) is demonstrated for the first time. The resulting ASSSs show high specific capacitance, good rate capability, and enhanced energy density or power density. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. High-resolution melting (HRM) re-analysis of a polyposis patients cohort reveals previously undetected heterozygous and mosaic APC gene mutations.

    Science.gov (United States)

    Out, Astrid A; van Minderhout, Ivonne J H M; van der Stoep, Nienke; van Bommel, Lysette S R; Kluijt, Irma; Aalfs, Cora; Voorendt, Marsha; Vossen, Rolf H A M; Nielsen, Maartje; Vasen, Hans F A; Morreau, Hans; Devilee, Peter; Tops, Carli M J; Hes, Frederik J

    2015-06-01

    Familial adenomatous polyposis is most frequently caused by pathogenic variants in either the APC gene or the MUTYH gene. The detection rate of pathogenic variants depends on the severity of the phenotype and sensitivity of the screening method, including sensitivity for mosaic variants. For 171 patients with multiple colorectal polyps without previously detectable pathogenic variant, APC was reanalyzed in leukocyte DNA by one uniform technique: high-resolution melting (HRM) analysis. Serial dilution of heterozygous DNA resulted in a lowest detectable allelic fraction of 6% for the majority of variants. HRM analysis and subsequent sequencing detected pathogenic fully heterozygous APC variants in 10 (6%) of the patients and pathogenic mosaic variants in 2 (1%). All these variants were previously missed by various conventional scanning methods. In parallel, HRM APC scanning was applied to DNA isolated from polyp tissue of two additional patients with apparently sporadic polyposis and without detectable pathogenic APC variant in leukocyte DNA. In both patients a pathogenic mosaic APC variant was present in multiple polyps. The detection of pathogenic APC variants in 7% of the patients, including mosaics, illustrates the usefulness of a complete APC gene reanalysis of previously tested patients, by a supplementary scanning method. HRM is a sensitive and fast pre-screening method for reliable detection of heterozygous and mosaic variants, which can be applied to leukocyte and polyp derived DNA.

  17. Against All Odds: Peace Education in Times of Crisis

    Science.gov (United States)

    Culp, Julian

    2017-01-01

    Contexts of violent, intractable conflict such as those present in Israel, Nigeria, or Iraq represent times of severe crisis. Reducing the high indices of violence is very urgent, but the attempts of establishing peaceful arrangements in the short- or medium-term usually fail. Peace education, by contrast, is a "long-term" endeavor to…

  18. Age, training, and previous experience predict race performance in long-distance inline skaters, not anthropometry.

    Science.gov (United States)

    Knechtle, Beat; Knechtle, Patrizia; Rüst, Christoph Alexander; Rosemann, Thomas; Lepers, Romuald

    2012-02-01

    The association of characteristics of anthropometry, training, and previous experience with race time in 84 recreational, long-distance, inline skaters at the longest inline marathon in Europe (111 km), the Inline One-eleven in Switzerland, was investigated to identify predictor variables for performance. Age, duration per training unit, and personal best time were the only three variables related to race time in a multiple regression, while none of the 16 anthropometric variables were related. Anthropometric characteristics seem to be of no importance for a fast race time in a long-distance inline skating race in contrast to training volume and previous experience, when controlled with covariates. Improving performance in a long-distance inline skating race might be related to a high training volume and previous race experience. Also, doing such a race requires a parallel psychological effort, mental stamina, focus, and persistence. This may be reflected in the preparation and training for the event. Future studies should investigate what motivates these athletes to train and compete.

  19. Timing of High-level Waste Disposal

    International Nuclear Information System (INIS)

    2008-01-01

    This study identifies key factors influencing the timing of high-level waste (HLW) disposal and examines how social acceptability, technical soundness, environmental responsibility and economic feasibility impact on national strategies for HLW management and disposal. Based on case study analyses, it also presents the strategic approaches adopted in a number of national policies to address public concerns and civil society requirements regarding long-term stewardship of high-level radioactive waste. The findings and conclusions of the study confirm the importance of informing all stakeholders and involving them in the decision-making process in order to implement HLW disposal strategies successfully. This study will be of considerable interest to nuclear energy policy makers and analysts as well as to experts in the area of radioactive waste management and disposal. (author)

  20. Quantum secret sharing based on modulated high-dimensional time-bin entanglement

    International Nuclear Information System (INIS)

    Takesue, Hiroki; Inoue, Kyo

    2006-01-01

    We propose a scheme for quantum secret sharing (QSS) that uses a modulated high-dimensional time-bin entanglement. By modulating the relative phase randomly by {0,π}, a sender with the entanglement source can randomly change the sign of the correlation of the measurement outcomes obtained by two distant recipients. The two recipients must cooperate if they are to obtain the sign of the correlation, which is used as a secret key. We show that our scheme is secure against intercept-and-resend (IR) and beam splitting attacks by an outside eavesdropper thanks to the nonorthogonality of high-dimensional time-bin entangled states. We also show that a cheating attempt based on an IR attack by one of the recipients can be detected by changing the dimension of the time-bin entanglement randomly and inserting two 'vacant' slots between the packets. Then, cheating attempts can be detected by monitoring the count rate in the vacant slots. The proposed scheme has better experimental feasibility than previously proposed entanglement-based QSS schemes

  1. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

    Science.gov (United States)

    Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J

    2010-10-01

    High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

  2. Effects of previous ionization and excitation on the ionization wave propagation along the dielectric tube

    International Nuclear Information System (INIS)

    Xia, Yang; Liu, Dongping; Bi, Zhenhua; Wang, Xueyang; Niu, Jinhai; Ji, Longfei; Song, Ying; Qi, Zhihua; Wang, Wenchun

    2016-01-01

    In this paper, by using a high precision synchronization system, the ignition time, velocity, and propagation properties of the ionization waves (IWs) have been investigated in detail from the 1st high voltage (HV) pulse to the sequential ones over a large range of the pulse-off time. In order to clarify the effects of previous ionization and excitation on the IW propagation, the density of the residual charges are controlled by varying the pulse-off time from 199 μs to 15 μs. The results show that the formation and propagation of IWs can be strongly affected by previous discharge. For a longer pulse-off time (100 μs–190 μs), the propagation velocity of plasma bullets are decreased from the 1st to the 10th HV pulse, then increased after the 10th pulse, and finally become stable after about 500 pulses. When the pulse-off time is reduced to 15 μs, the propagation velocity of plasma bullets will rapidly increase and become stable after the 1st HV pulse. The ignition voltage is significantly reduced after the 1st HV pulse with the decrease in pulse-off time. Consequently, the generation and propagation of IWs in the tube are strongly affected by the accumulation of long-lived metastable helium (He) species and residual charges from previous discharges, which is important for understanding the plasma bullet behavior. (paper)

  3. Typhi–Induced Septic Shock and Acute Respiratory Distress Syndrome in a Previously Healthy Teenage Patient Treated With High-Dose Dexamethasone

    Directory of Open Access Journals (Sweden)

    Melissa Brosset Ugas MD

    2016-05-01

    Full Text Available Typhoid fever is commonly characterized by fever and abdominal pain. Rare complications include intestinal hemorrhage, bowel perforation, delirium, obtundation, and septic shock. Herein we describe the case of a previously healthy 16-year-old male without history of travel, diagnosed with typhoid fever complicated by septic shock and acute respiratory distress syndrome treated with high-dose dexamethasone. This case details severe complications of typhoid fever that are uncommonly seen in developed countries, and the successful response to high-dose dexamethasone as adjunct therapy. High-dose dexamethasone treatment has reportedly decreased Salmonella Typhi mortality, but controlled studies specifically performed in children are lacking, and most reports of its use are over 30 years old and all have originated in developing countries. Providers should include Salmonella Typhi in the differential diagnosis of the pediatric patient with fever, severe abdominal pain, and enteritis, and be aware of its potentially severe complications and the limited data on safety and efficacy of adjunctive therapies that can be considered in addition to antibiotics.

  4. Detection of all Chlamydophila and Chlamydia spp. of veterinary interest using species-specific real-time PCR assays.

    Science.gov (United States)

    Pantchev, Alexandra; Sting, Reinhard; Bauerfeind, Rolf; Tyczka, Judith; Sachse, Konrad

    2010-12-01

    The aim of the present study was to analyse the occurrence of chlamydiae in several mammalian host species. Clinical samples that previously tested positive in a Chlamydiaceae-specific real-time PCR were retested using six species-specific real-time PCR assays to identify the chlamydial species involved. Chlamydophila (Cp.) abortus was the agent most frequently found in cattle, sheep, horses, goats, and pigs. Detection in cattle of Cp. psittaci (11% of samples) and Chlamydia (C.) suis (9%), as well as Cp. psittaci in a goat sample was somewhat unexpected. DNA of two different chlamydiae was identified in 56 (12.7%) of 440 samples tested. Cp. felis was the predominant species found in cats, while in guinea pigs and rabbits only Cp. caviae was detected. Interestingly, the latter two pathogens were also identified in samples from dogs. The data show that mixed chlamydial infections are not rare and suggest an extended host range of individual species. Copyright © 2009 Elsevier Ltd. All rights reserved.

  5. Pulse shaping for all-optical signal processing of ultra-high bit rate serial data signals

    DEFF Research Database (Denmark)

    Palushani, Evarist

    The following thesis concerns pulse shaping and optical waveform manipulation for all-optical signal processing of ultra-high bit rate serial data signals, including generation of optical pulses in the femtosecond regime, serial-to-parallel conversion and terabaud coherent optical time division...

  6. SFG synthesis of general high-order all-pass and all-pole current transfer functions using CFTAs.

    Science.gov (United States)

    Tangsrirat, Worapong

    2014-01-01

    An approach of using the signal flow graph (SFG) technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs) and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the g m-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory.

  7. SFG Synthesis of General High-Order All-Pass and All-Pole Current Transfer Functions Using CFTAs

    Directory of Open Access Journals (Sweden)

    Worapong Tangsrirat

    2014-01-01

    Full Text Available An approach of using the signal flow graph (SFG technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the gm-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory.

  8. Seasonal Dependence of Geomagnetic Active-Time Northern High-Latitude Upper Thermospheric Winds

    Science.gov (United States)

    Dhadly, Manbharat S.; Emmert, John T.; Drob, Douglas P.; Conde, Mark G.; Doornbos, Eelco; Shepherd, Gordon G.; Makela, Jonathan J.; Wu, Qian; Nieciejewski, Richard J.; Ridley, Aaron J.

    2018-01-01

    This study is focused on improving the poorly understood seasonal dependence of northern high-latitude F region thermospheric winds under active geomagnetic conditions. The gaps in our understanding of the dynamic high-latitude thermosphere are largely due to the sparseness of thermospheric wind measurements. With current observational facilities, it is infeasible to construct a synoptic picture of thermospheric winds, but enough data with wide spatial and temporal coverage have accumulated to construct a meaningful statistical analysis. We use long-term data from eight ground-based and two space-based instruments to derive climatological wind patterns as a function of magnetic local time, magnetic latitude, and season. These diverse data sets possess different geometries and different spatial and solar activity coverage. The major challenge is to combine these disparate data sets into a coherent picture while overcoming the sampling limitations and biases among them. In our previous study (focused on quiet time winds), we found bias in the Gravity Field and Steady State Ocean Circulation Explorer (GOCE) cross-track winds. Here we empirically quantify the GOCE bias and use it as a correction profile for removing apparent bias before empirical wind formulation. The assimilated wind patterns exhibit all major characteristics of high-latitude neutral circulation. The latitudinal extent of duskside circulation expands almost 10∘ from winter to summer. The dawnside circulation subsides from winter to summer. Disturbance winds derived from geomagnetic active and quiet winds show strong seasonal and latitudinal variability. Comparisons between wind patterns derived here and Disturbance Wind Model (DWM07) (which have no seasonal dependence) suggest that DWM07 is skewed toward summertime conditions.

  9. Separable processes before, during, and after the N400 elicited by previously inferred and new information: evidence from time-frequency decompositions.

    Science.gov (United States)

    Steele, Vaughn R; Bernat, Edward M; van den Broek, Paul; Collins, Paul F; Patrick, Christopher J; Marsolek, Chad J

    2013-01-25

    Successful comprehension during reading often requires inferring information not explicitly presented. This information is readily accessible when subsequently encountered, and a neural correlate of this is an attenuation of the N400 event-related potential (ERP). We used ERPs and time-frequency (TF) analysis to investigate neural correlates of processing inferred information after a causal coherence inference had been generated during text comprehension. Participants read short texts, some of which promoted inference generation. After each text, they performed lexical decisions to target words that were unrelated or inference-related to the preceding text. Consistent with previous findings, inference-related words elicited an attenuated N400 relative to unrelated words. TF analyses revealed unique contributions to the N400 from activity occurring at 1-6 Hz (theta) and 0-2 Hz (delta), supporting the view that multiple, sequential processes underlie the N400. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Optimization of extraction of high purity all-trans-lycopene from tomato pulp waste.

    Science.gov (United States)

    Poojary, Mahesha M; Passamonti, Paolo

    2015-12-01

    The aim of this work was to optimize the extraction of pure all-trans-lycopene from the pulp fractions of tomato processing waste. A full factorial design (FFD) consisting of four independent variables including extraction temperature (30-50 °C), time (1-60 min), percentage of acetone in n-hexane (25-75%, v/v) and solvent volume (10-30 ml) was used to investigate the effects of process variables on the extraction. The absolute amount of lycopene present in the pulp waste was found to be 0.038 mg/g. The optimal conditions for extraction were as follows: extraction temperature 20 °C, time 40 min, a solvent composition of 25% acetone in n-hexane (v/v) and solvent volume 40 ml. Under these conditions, the maximal recovery of lycopene was 94.7%. The HPLC-DAD analysis demonstrated that, lycopene was obtained in the all-trans-configuration at a very high purity grade of 98.3% while the amount of cis-isomers and other carotenoids were limited. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  12. Multi-species time-history measurements during high-temperature acetone and 2-butanone pyrolysis

    KAUST Repository

    Lam, Kingyiu

    2013-01-01

    High-temperature acetone and 2-butanone pyrolysis studies were conducted behind reflected shock waves using five species time-history measurements (ketone, CO, CH3, CH4 and C2H4). Experimental conditions covered temperatures of 1100-1600 Kat 1.6 atm, for mixtures of 0.25-1.5% ketone in argon. During acetone pyrolysis, the CO concentration time-history was found to be strongly sensitive to the acetone dissociation rate constant κ1 (CH3COCH3 → CH3 + CH3CO), and this could be directly determined from the CO time-histories, yielding κ1(1.6 atm) = 2.46 × 1014 exp(-69.3 [kcal/mol]/RT) s-1 with an uncertainty of ±25%. This rate constant is in good agreement with previous shock tube studies from Sato and Hidaka (2000) [3] and Saxena et al. (2009) [4] (within 30%) at temperatures above 1450 K, but is at least three times faster than the evaluation from Sato and Hidaka at temperatures below 1250 K. Using this revised κ1 value with the recent mechanism of Pichon et al. (2009) [5], the simulated profiles during acetone pyrolysis show excellent agreement with all five species time-history measurements. Similarly, the overall 2-butanone decomposition rate constant κtot was inferred from measured 2-butanone time-histories, yielding κ tot(1.5 atm) = 6.08 × 1013 exp(-63.1 [kcal/mol]/RT) s -1 with an uncertainty of ±35%. This rate constant is approximately 30% faster than that proposed by Serinyel et al. (2010) [11] at 1119 K, and approximately 100% faster at 1412 K. Using the measured 2-butanone and CO time-histories and an O-atom balance analysis, a missing removal pathway for methyl ketene was identified. The rate constant for the decomposition of methyl ketene was assumed to be the same as the value for the ketene decomposition reaction. Using the revised κtot value and adding the methyl ketene decomposition reaction to the Serinyel et al. mechanism, the simulated profiles during 2-butanone pyrolysis show good agreement with the measurements for all five species.

  13. [Selective biopsy of the sentinel lymph node in patients with breast cancer and previous excisional biopsy: is there a change in the reliability of the technique according to time from surgery?].

    Science.gov (United States)

    Sabaté-Llobera, A; Notta, P C; Benítez-Segura, A; López-Ojeda, A; Pernas-Simon, S; Boya-Román, M P; Bajén, M T

    2015-01-01

    To assess the influence of time on the reliability of sentinel lymph node biopsy (SLNB) in breast cancer patients with previous excisional biopsy (EB), analyzing both the sentinel lymph node detection and the lymph node recurrence rate. Thirty-six patients with cT1/T2 N0 breast cancer and previous EB of the lesion underwent a lymphoscintigraphy after subdermal periareolar administration of radiocolloid, the day before SLNB. Patients were classified into two groups, one including 12 patients with up to 29 days elapsed between EB and SLNB (group A), and another with the remaining 24 in which time between both procedures was of 30 days or more (group B). Scintigraphic and surgical detection of the sentinel lymph node, histological status of the sentinel lymph node and of the axillary lymph node dissection, if performed, and lymphatic recurrences during follow-up, were analyzed. Sentinel lymph node visualization at the lymphoscintigraphy and surgical detection were 100% in both groups. Histologically, three patients showed macrometastasis in the sentinel lymph node, one from group A and two from group B. None of the patients, not even those with malignancy of the sentinel lymph node, relapsed after a medium follow-up of 49.5 months (24-75). Time elapsed between EB and SLNB does not influence the reliability of this latter technique as long as a superficial injection of the radiopharmaceutical is performed, proving a very high detection rate of the sentinel lymph node without evidence of lymphatic relapse during follow-up. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  14. Total hip arthroplasty after a previous pelvic osteotomy: A systematic review and meta-analysis.

    Science.gov (United States)

    Shigemura, T; Yamamoto, Y; Murata, Y; Sato, T; Tsuchiya, R; Wada, Y

    2018-06-01

    There are several reports regarding total hip arthroplasty (THA) after a previous pelvic osteotomy (PO). However, to our knowledge, until now there has been no formal systematic review and meta-analysis published to summarize the clinical results of THA after a previous PO. Therefore, we conducted a systematic review and meta-analysis of results of THA after a previous PO. We focus on these questions as follows: does a previous PO affect the results of subsequent THA, such as clinical outcomes, operative time, operative blood loss, and radiological parameters. Using PubMed, Web of Science, and Cochrane Library, we searched for relevant original papers. The pooling of data was performed using RevMan software (version 5.3, Cochrane Collaboration, Oxford, UK). A p-value50%, significant heterogeneity was assumed and a random-effects model was applied for the meta-analysis. A fixed-effects model was applied in the absence of significant heterogeneity. Eleven studies were included in this meta-analysis. The pooled results indicated that there was no significant difference in postoperative Merle D'Aubigne-Postel score (I 2 =0%, SMD=-0.15, 95% CI: -0.36 to 0.06, p=0.17), postoperative Harris hip score (I 2 =60%, SMD=-0.23, 95% CI: -0.50 to 0.05, p=0.10), operative time (I 2 =86%, SMD=0.37, 95% CI: -0.09 to 0.82, p=0.11), operative blood loss (I 2 =82%, SMD=0.23, 95% CI: -0.17 to 0.63, p=0.25), and cup abduction angle (I 2 =43%, SMD=-0.08, 95% CI: -0.25 to 0.09, p=0.38) between THA with and without a previous PO. However, cup anteversion angle of THA with a previous PO was significantly smaller than that of without a previous PO (I 2 =77%, SMD=-0.63, 95% CI: -1.13 to -0.13, p=0.01). Systematic review and meta-analysis of results of THA after a previous PO was performed. A previous PO did not affect the results of subsequent THA, except for cup anteversion. Because of the low quality evidence currently available, high-quality randomized controlled trials are required

  15. Laparoscopy After Previous Laparotomy

    Directory of Open Access Journals (Sweden)

    Zulfo Godinjak

    2006-11-01

    Full Text Available Following the abdominal surgery, extensive adhesions often occur and they can cause difficulties during laparoscopic operations. However, previous laparotomy is not considered to be a contraindication for laparoscopy. The aim of this study is to present that an insertion of Veres needle in the region of umbilicus is a safe method for creating a pneumoperitoneum for laparoscopic operations after previous laparotomy. In the last three years, we have performed 144 laparoscopic operations in patients that previously underwent one or two laparotomies. Pathology of digestive system, genital organs, Cesarean Section or abdominal war injuries were the most common causes of previouslaparotomy. During those operations or during entering into abdominal cavity we have not experienced any complications, while in 7 patients we performed conversion to laparotomy following the diagnostic laparoscopy. In all patients an insertion of Veres needle and trocar insertion in the umbilical region was performed, namely a technique of closed laparoscopy. Not even in one patient adhesions in the region of umbilicus were found, and no abdominal organs were injured.

  16. Simulating detectors dead time

    International Nuclear Information System (INIS)

    Rustom, Ibrahim Farog Ibrahim

    2015-06-01

    Nuclear detectors are used in all aspects of nuclear measurements. All nuclear detectors are characterized by their dead time i.e. the time needed by a detector to recover from a previous incident. A detector dead time influences measurements taken by a detector and specially when measuring high decay rate (>) where is the detector dead time. Two models are usually used to correct for the dead time effect: the paralayzable and the non-paralayzable models. In the current work we use Monte Carlo simulation techniques to simulate radioactivity and the effect of dead time and the count rate of a detector with a dead time =5x10 - 5s assuming the non-paralayzable model. The simulation indicates that assuming a non -paralayzable model could be used to correct for decay rate measured by a detector. The reliability of the non-paralayzable model to correct the measured decay rate could be gauged using the Monte Carlo simulation. (Author)

  17. A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress.

    Science.gov (United States)

    Gozdowski, S; Reich, S

    2009-01-01

    Apart from precision, the time factor plays a decisive role in the fabrication of all-ceramic dental restorations. Therefore, the aim of this study was to compare two all-ceramic systems with regard to the time required for the fabrication of partial crowns [MODB]. The null hypothesis tested was that the fabrication times of CAD/CAM generated partial crowns are shorter than the fabrication times of partial crowns manufactured in the laboratory. In sixteen model pairs mounted in the articulator, which corresponded to different clinical situations, tooth 36 was prepared for an all-ceramic partial crown [MODB]. With the Cerec3D method [CHAIR], the fabrication of the restoration was simulated directly on the "phantom patient". The IPS Empress system [LAB] was used forthe indirectfabrication method via an impression of the phantom patient. Both methods were used for each preparation. The adhesive luting procedure was not simulated and, therefore, not measured. The mean processing times [hh:mm:ss] were 00:35:05 (SD +/- 03:27 min) for the Cerec method and 04:17:54 (SD +/- 26:01 min) for the Empress method. The mean time on the phantom patient for process-induced activities was 11:47 minutes (SD +/- 02:08 min) for the Cerec method and 03:58 minutes (SD +/- 02:50 min) for the Empress method. Time expenditure for fabrication is only one aspect in order to assess the suitability of a restoration system. Both methods enable the dentist to provide high quality all ceramic restorations. Although the Empress method showed a time advantage of 65% during the fitting phase and occlusal grinding-in on the phantom patient in comparison to the Cerec method, the time spent during the laboratory phase has to be considered as well.

  18. Should all suspected tuberculosis cases in high income countries be tested with GeneXpert?

    Science.gov (United States)

    Vella, Venanzio; Broda, Agnieszka; Drobniewski, Francis

    2018-05-01

    In countries with a low incidence of multidrug-resistant tuberculosis (MDR-TB), universal testing with GeneXpert might not be always cost-effective. This study provides hospital managers in low MDR-TB incidence countries with criteria on when decentralised universal GeneXpert testing would make sense. The alternatives taken into consideration include: universal microbiological culture and drug susceptibility testing (DST) only (comparator); as above but with concurrent centralized GeneXpert in a referral laboratory vs a decentralized GeneXpert system in every hospital to test smear-positive cases only; as above but testing all samples with GeneXpert regardless of smear status. The parameters were from the national TB statistics for England and from a systematic review. Decentralised GeneXpert to test any suspected TB case was the most cost-effective option when 6% or more TB patients belonged to the high-risk group, defined as previous TB diagnosis and or being born in countries with a high MDR-TB incidence. Hospital managers in England and other low MDR-TB incidence countries could use these findings to decide when to invest in GeneXpert or other molecular diagnostics with similar performance criteria for TB diagnostics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Delayed high school start times later than 8:30am and impact on graduation rates and attendance rates.

    Science.gov (United States)

    McKeever, Pamela Malaspina; Clark, Linda

    2017-04-01

    The first purpose of this study was to investigate changes in high school graduation rates with a delayed school start time of later than 8:30am. The second aim of the study was to analyze the association between a delayed high school start time later than 8:30am and attendance rates. In the current study, a pre-post design using a repeated-measures analysis of variance was used to examine changes in attendance and graduation rates 2 years after a delayed start was implemented. Public high schools from 8 school districts (n=29 high schools) located throughout 7 different states. Schools were identified using previous research from the Children's National Medical Center's Division of Sleep Medicine Research Team. A total membership of more than 30,000 high school students enrolled in the 29 schools identified by the Children's National Medical Center's Research Team. A pre-post design was used for a within-subject design, controlling for any school-to-school difference in the calculation of the response variable. This is the recommended technique for a study that may include data with potential measurement error. Findings from this study linked a start time of later than 8:30am to improved attendance rates and graduation rates. Attendance rates and graduation rates significantly improved in schools with delayed start times of 8:30am or later. School officials need to take special notice that this investigation also raises questions about whether later start times are a mechanism for closing the achievement gap due to improved graduation rates. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  20. All inkjet printed 3D microwave capacitors and inductors with vias

    KAUST Repository

    McKerricher, Garret

    2013-06-01

    For the first time we present a method to create all inkjet printed multilayer RF passive components including vias. Although there has been previous work on multilayer RF components, they are not fully inkjet printed and involve complicated processing techniques such as laser cutting, conductive epoxy, or reactive ion etching This work demonstrates a truly all inkjet printed solution with a novel dissolving method for vias realization. A major issue with inkjet printing is often surface roughness, however by processing these materials at low temperature surface roughness <20nm RMS has been obtained which allows for high quality components to be fabricated and allows for stacked multilayer designs. © 2013 IEEE.

  1. All inkjet printed 3D microwave capacitors and inductors with vias

    KAUST Repository

    McKerricher, Garret; Gonzá lez, Juan Carlos Cano; Shamim, Atif

    2013-01-01

    For the first time we present a method to create all inkjet printed multilayer RF passive components including vias. Although there has been previous work on multilayer RF components, they are not fully inkjet printed and involve complicated processing techniques such as laser cutting, conductive epoxy, or reactive ion etching This work demonstrates a truly all inkjet printed solution with a novel dissolving method for vias realization. A major issue with inkjet printing is often surface roughness, however by processing these materials at low temperature surface roughness <20nm RMS has been obtained which allows for high quality components to be fabricated and allows for stacked multilayer designs. © 2013 IEEE.

  2. All-Optical Signal processing using Highly Nonlinear Photonic Crystal Fiber

    DEFF Research Database (Denmark)

    Andersen, Peter Andreas

    2006-01-01

    -optical regeneration is the only possible way of regenerating a signal with the current technology. Transforming the current telecommunication network into an all-optical network will require an all-optical regeneration of the optical signal. At the current time (May 2005) all-optical regeneration is a tool only used......The use of HNL-PCF in optical communication systems has been investigated in this thesis. The investigation has been done with respect to the future of telecommunications in an all-optical system. The PCFs used have all been used for all-optical signal processing as part of an optical component...... and the possibility of large differences between the refractive indices of the core and the cladding by using air-holes, makes PCFs suited for custom made components. By testing a HNL-PCF as a medium for supercontinuum generation at various dispersion values and at the same time using that supercontinuum...

  3. Time course of changes in cerebral blood flow velocity after tourniquet deflation in patients with diabetes mellitus or previous stroke under sevoflurane anesthesia.

    Science.gov (United States)

    Hinohara, Hiroshi; Kadoi, Yuji; Takahashi, Kenichiro; Saito, Shigeru; Kawauchi, Chikara; Mizutani, Akio

    2011-06-01

    We observed an increase in mean middle cerebral artery blood flow velocity (V(mca)) after tourniquet deflation during orthopedic surgery under sevoflurane anesthesia in patients with diabetes mellitus or previous stroke. Eight controls, seven insulin-treated diabetic patients, and eight previous stroke patients were studied. Arterial blood pressure, heart rate, V(mca), arterial blood gases, and plasma lactate levels were measured every minute for 10 min after tourniquet release in all patients. V(mca) was measured using a transcranial Doppler probe. V(mca) in all three groups increased after tourniquet deflation, the increase lasting for 4 or 5 min. However, the degree of increase in V(mca) in the diabetic patients was smaller than that in the other two groups after tourniquet deflation (at 2 min after tourniquet deflation: control 58.5 ± 3.3, previous stroke 58.4 ± 4.6, diabetes 51.7 ± 2.3; P < 0.05 compared with the other two groups). In conclusion, the degree of increase in V (mca) in diabetic patients is smaller than that in controls and patients with previous stroke.

  4. High repetition rate, high energy, actively Q-switched all-in-fiber laser

    Science.gov (United States)

    Lecourt, J. B.; Bertrand, A.; Guillemet, S.; Hernandez, Y.; Giannone, D.

    2010-05-01

    We report an actively Q-switched Ytterbium-doped all-in-fibre laser delivering 10ns pulses with high repetition rate (from 100kHz to 1MHz). The laser operation has been validated at three different wavelengths (1040, 1050 and 1064nm). The laser can deliver up to 20Watts average power with an high beam quality (M2 = 1).

  5. How to prevent type 2 diabetes in women with previous gestational diabetes?

    DEFF Research Database (Denmark)

    Pedersen, Anne Louise Winkler; Terkildsen Maindal, Helle; Juul, Lise

    2017-01-01

    OBJECTIVES: Women with previous gestational diabetes (GDM) have a seven times higher risk of developing type 2 diabetes (T2DM) than women without. We aimed to review the evidence of effective behavioural interventions seeking to prevent T2DM in this high-risk group. METHODS: A systematic review...... of RCTs in several databases in March 2016. RESULTS: No specific intervention or intervention components were found superior. The pooled effect on diabetes incidence (four trials) was estimated to: -5.02 per 100 (95% CI: -9.24; -0.80). CONCLUSIONS: This study indicates that intervention is superior...... to no intervention in prevention of T2DM among women with previous GDM....

  6. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  7. The Recidivism Patterns of Previously Deported Aliens Released from a Local Jail: Are They High-Risk Offenders?

    Science.gov (United States)

    Hickman, Laura J.; Suttorp, Marika J.

    2010-01-01

    Previously deported aliens are a group about which numerous claims are made but very few facts are known. Using data on male deportable aliens released from a local jail, the study sought to test the ubiquitous claim that they pose a high risk of recidivism. Using multiple measures of recidivism and propensity score weighting to account for…

  8. Pleasing all the people all the time

    International Nuclear Information System (INIS)

    Thome-Jassaud, Pierre-Franck

    2002-01-01

    The Cattenom nuclear power plant is located less than 20 km from the German and Belgian borders and less than 1 km from the border with Luxemburg. Two of these countries, Germany and Luxemburg, have adopted positions which are relatively hostile to nuclear power, and are characterised by a strong ecologist minority. In 1979 a referendum in Luxemburg rejected the construction of a nuclear power plant in the country. Twenty years later, Germany opted to withdraw from the nuclear program. In this context, France's decision to build a nuclear power plant on the border with the two countries was seen in a poor light. Right from the beginning of construction work, the German and Luxemburg ecologists noisily demonstrated their hostility to the site. But for the Lorraine region, the construction of Cattenom was a real opportunity. Lorraine has a long tradition of steel making but was currently going through a serious economic crisis with most of its blast furnaces being closed down. Apart from providing the answer to the high demand for electricity, the Cattenom plant meant large-scale employment. (author)

  9. Timing of elective repeated cesarean delivery in patients with previous two or more cesarean section.

    Science.gov (United States)

    Mohammed, Abdel-Baset F; Bayo, Arabo I; Abu-Jubara, Mahmoud F

    2013-01-01

    To assess the maternal and neonatal consequences of scheduling elective repeated cesarean section (ERCS) at 39 weeks rather than 38 weeks and to assess the impacts of delivering by emergency cesarean section (CS) before the planned date. Retrospective Cohort study. Patients with previous two or more CS planned for ERCS at term during the period from January to June 2011. Medical records were reviewed for demographic and clinical data, planned timing of CS, emergency cesarean and any adverse maternal or neonatal outcome. Adverse maternal or neonatal outcome. Four hundred and twenty women were included, 71.4% of cases were posted <39 weeks and 28.6% were posted at ≥39 weeks. Patients posted ≥ 39 weeks were more prone to deliver by emergency CS (16.6 vs. 10.6%) and the neonates were less prone to RDS and NICU admission (p < 0.05). Our data support the justification to book patients for ERCS at ≥39 weeks.

  10. All-optical ultra-high-speed OFDM to Nyquist-WDM conversion

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Mulvad, Hans Christian Hansen

    2015-01-01

    We propose an all-optical ultra-high-speed OFDM to Nyquist-WDM conversion scheme based on complete OFT. An 8-subcarrier 640 Gbit/s DPSK OFDM super-channel is converted to eight 80-Gbit/s Nyquist-WDM channels with BER <10−9 performance for all channels.......We propose an all-optical ultra-high-speed OFDM to Nyquist-WDM conversion scheme based on complete OFT. An 8-subcarrier 640 Gbit/s DPSK OFDM super-channel is converted to eight 80-Gbit/s Nyquist-WDM channels with BER

  11. Interference from previous distraction disrupts older adults' memory.

    Science.gov (United States)

    Biss, Renée K; Campbell, Karen L; Hasher, Lynn

    2013-07-01

    Previously relevant information can disrupt the ability of older adults to remember new information. Here, the researchers examined whether prior irrelevant information, or distraction, can also interfere with older adults' memory for new information. Younger and older adults first completed a 1-back task on pictures that were superimposed with distracting words. After a delay, participants learned picture-word paired associates and memory was tested using picture-cued recall. In 1 condition (high interference), some pairs included pictures from the 1-back task now paired with new words. In a low-interference condition, the transfer list used all new items. Older adults had substantially lower cued-recall performance in the high- compared with the low-interference condition. In contrast, younger adults' performance did not vary across conditions. These findings suggest that even never-relevant information from the past can disrupt older adults' memory for new associations.

  12. High-effective position time spectrometer in actual measurements of low intensity region of electron spectra

    International Nuclear Information System (INIS)

    Babenkov, M.I.; Zhdanov, V.S.

    2002-01-01

    Magnetic position-time spectrometer was proposed in previous work, where not only electron coordinates in focal plane are measured by position sensitive detector (PSD) but places of their birth in beta source plane of a large area are fixed using another PSD, situated behind it, by quick effects, accompanying radioactive decay. PSD on the basis of macro-channel plates are used. It is succeeded in position-time spectrometer to combine beta sources of a large area with multichannel registration for a wide energy interval, that efficiency of measurements was two orders of magnitude increase d in comparison magnetic apparatus having PSD only in focal plane. Owing to two detectors' switching on coincidence the relation effect/background in increased minimum on two orders of magnitude in comparison with the same apparatus. At some complication of mathematical analysis it was obtained, that high characteristics of position-time spectrometer are kept during the use the magnetic field, providing double focusing. Owning to this focusing the gain the efficiency of measurements will make one more order of magnitude. Presented high-effective position-time spectrometer is supposed to use in the measurements of low-intensity region of electron spectra, which are important for development of fundamental physics. This is the first of all estimation of electron anti-neutrino mass by the form of beta spectrum of tritium in the region of boundary energy. Recently here there was problem of non physical negative values. This problem can be solved by using in measurement of different in principle high-effective spectrometers, which possess improved background properties. A position-time spectrometers belongs to these apparatus, which provides the best background conditions at very large effectiveness of the measurements of tritium beta spectrum in the region of boundary energy with acceptable high resolution. An important advantage of position-time spectrometer is the possibility of

  13. Urethrotomy has a much lower success rate than previously reported.

    Science.gov (United States)

    Santucci, Richard; Eisenberg, Lauren

    2010-05-01

    We evaluated the success rate of direct vision internal urethrotomy as a treatment for simple male urethral strictures. A retrospective chart review was performed on 136 patients who underwent urethrotomy from January 1994 through March 2009. The Kaplan-Meier method was used to analyze stricture-free probability after the first, second, third, fourth and fifth urethrotomy. Patients with complex strictures (36) were excluded from the study for reasons including previous urethroplasty, neophallus or previous radiation, and 24 patients were lost to followup. Data were available for 76 patients. The stricture-free rate after the first urethrotomy was 8% with a median time to recurrence of 7 months. For the second urethrotomy stricture-free rate was 6% with a median time to recurrence of 9 months. For the third urethrotomy stricture-free rate was 9% with a median time to recurrence of 3 months. For procedures 4 and 5 stricture-free rate was 0% with a median time to recurrence of 20 and 8 months, respectively. Urethrotomy is a popular treatment for male urethral strictures. However, the performance characteristics are poor. Success rates were no higher than 9% in this series for first or subsequent urethrotomy during the observation period. Most of the patients in this series will be expected to experience failure with longer followup and the expected long-term success rate from any (1 through 5) urethrotomy approach is 0%. Urethrotomy should be considered a temporizing measure until definitive curative reconstruction can be planned. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems

    International Nuclear Information System (INIS)

    Suresh Babu, R.M.

    1995-01-01

    With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs

  15. Ultraflexible and tailorable all-solid-state supercapacitors using polyacrylamide-based hydrogel electrolyte with high ionic conductivity.

    Science.gov (United States)

    Li, Huili; Lv, Tian; Li, Ning; Yao, Yao; Liu, Kai; Chen, Tao

    2017-11-30

    Hydrogels with high ionic conductivity consisting of a cross-linked polymer network swollen in water are very promising to be used as an electrolyte for all-solid-state supercapacitors. However, there are rather few flexible supercapacitors using ionic conducting hydrogel electrolytes reported to date. In this work, highly flexible and ionic conducting polyacrylamide hydrogels were synthesized through a simple approach. On using the ionic hydrogels as the electrolyte, the resulting supercapacitors not only exhibited a high specific capacitance but also showed a long self-discharge time (over 10 hours to the half of original open-circuit voltage) and a low leakage current. These newly-developed all-solid-state supercapacitors can be bent, knot, and kneaded for 5000 cycles without performance decay, suggesting excellent flexibility and mechanical stability. These all-solid-state supercapacitors can also be easily tailored into strip-like supercapacitors without a short circuit, which provides an efficient approach to fabricate wearable energy storage devices.

  16. Determining root correspondence between previously and newly detected objects

    Science.gov (United States)

    Paglieroni, David W.; Beer, N Reginald

    2014-06-17

    A system that applies attribute and topology based change detection to networks of objects that were detected on previous scans of a structure, roadway, or area of interest. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, size, elongation, orientation, etc. The topology of the network of previously detected objects is maintained in a constellation database that stores attributes of previously detected objects and implicitly captures the geometrical structure of the network. A change detection system detects change by comparing the attributes and topology of new objects detected on the latest scan to the constellation database of previously detected objects.

  17. High-resolution and super stacking of time-reversal mirrors in locating seismic sources

    KAUST Repository

    Cao, Weiping

    2011-07-08

    Time reversal mirrors can be used to backpropagate and refocus incident wavefields to their actual source location, with the subsequent benefits of imaging with high-resolution and super-stacking properties. These benefits of time reversal mirrors have been previously verified with computer simulations and laboratory experiments but not with exploration-scale seismic data. We now demonstrate the high-resolution and the super-stacking properties in locating seismic sources with field seismic data that include multiple scattering. Tests on both synthetic data and field data show that a time reversal mirror has the potential to exceed the Rayleigh resolution limit by factors of 4 or more. Results also show that a time reversal mirror has a significant resilience to strong Gaussian noise and that accurate imaging of source locations from passive seismic data can be accomplished with traces having signal-to-noise ratios as low as 0.001. Synthetic tests also demonstrate that time reversal mirrors can sometimes enhance the signal by a factor proportional to the square root of the product of the number of traces, denoted as N and the number of events in the traces. This enhancement property is denoted as super-stacking and greatly exceeds the classical signal-to-noise enhancement factor of. High-resolution and super-stacking are properties also enjoyed by seismic interferometry and reverse-time migration with the exact velocity model. © 2011 European Association of Geoscientists & Engineers.

  18. Should previous mammograms be digitised in the transition to digital mammography?

    International Nuclear Information System (INIS)

    Taylor-Phillips, S.; Gale, A.G.; Wallis, M.G.

    2009-01-01

    Breast screening specificity is improved if previous mammograms are available, which presents a challenge when converting to digital mammography. Two display options were investigated: mounting previous film mammograms on a multiviewer adjacent to the workstation, or digitising them for soft copy display. Eight qualified screen readers were videotaped undertaking routine screen reading for two 45-min sessions in each scenario. Analysis of gross eye and head movements showed that when digitised, previous mammograms were examined a greater number of times per case (p=0.03), due to a combination of being used in 19% more cases (p=0.04) and where used, looked at a greater number of times (28% increase, p=0.04). Digitising previous mammograms reduced both the average time taken per case by 18% (p=0.04) and the participants' perceptions of workload (p < 0.05). Digitising previous analogue mammograms may be advantageous, in particular in increasing their level of use. (orig.)

  19. Highly Crumpled All-Carbon Transistors for Brain Activity Recording.

    Science.gov (United States)

    Yang, Long; Zhao, Yan; Xu, Wenjing; Shi, Enzheng; Wei, Wenjing; Li, Xinming; Cao, Anyuan; Cao, Yanping; Fang, Ying

    2017-01-11

    Neural probes based on graphene field-effect transistors have been demonstrated. Yet, the minimum detectable signal of graphene transistor-based probes is inversely proportional to the square root of the active graphene area. This fundamentally limits the scaling of graphene transistor-based neural probes for improved spatial resolution in brain activity recording. Here, we address this challenge using highly crumpled all-carbon transistors formed by compressing down to 16% of its initial area. All-carbon transistors, chemically synthesized by seamless integration of graphene channels and hybrid graphene/carbon nanotube electrodes, maintained structural integrity and stable electronic properties under large mechanical deformation, whereas stress-induced cracking and junction failure occurred in conventional graphene/metal transistors. Flexible, highly crumpled all-carbon transistors were further verified for in vivo recording of brain activity in rats. These results highlight the importance of advanced material and device design concepts to make improvements in neuroelectronics.

  20. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  1. THE STATISTICS OF RADIO ASTRONOMICAL POLARIMETRY: BRIGHT SOURCES AND HIGH TIME RESOLUTION

    International Nuclear Information System (INIS)

    Van Straten, W.

    2009-01-01

    A four-dimensional statistical description of electromagnetic radiation is developed and applied to the analysis of radio pulsar polarization. The new formalism provides an elementary statistical explanation of the modal-broadening phenomenon in single-pulse observations. It is also used to argue that the degree of polarization of giant pulses has been poorly defined in past studies. Single- and giant-pulse polarimetry typically involves sources with large flux-densities and observations with high time-resolution, factors that necessitate consideration of source-intrinsic noise and small-number statistics. Self-noise is shown to fully explain the excess polarization dispersion previously noted in single-pulse observations of bright pulsars, obviating the need for additional randomly polarized radiation. Rather, these observations are more simply interpreted as an incoherent sum of covariant, orthogonal, partially polarized modes. Based on this premise, the four-dimensional covariance matrix of the Stokes parameters may be used to derive mode-separated pulse profiles without any assumptions about the intrinsic degrees of mode polarization. Finally, utilizing the small-number statistics of the Stokes parameters, it is established that the degree of polarization of an unresolved pulse is fundamentally undefined; therefore, previous claims of highly polarized giant pulses are unsubstantiated.

  2. Non-linear forecasting in high-frequency financial time series

    Science.gov (United States)

    Strozzi, F.; Zaldívar, J. M.

    2005-08-01

    A new methodology based on state space reconstruction techniques has been developed for trading in financial markets. The methodology has been tested using 18 high-frequency foreign exchange time series. The results are in apparent contradiction with the efficient market hypothesis which states that no profitable information about future movements can be obtained by studying the past prices series. In our (off-line) analysis positive gain may be obtained in all those series. The trading methodology is quite general and may be adapted to other financial time series. Finally, the steps for its on-line application are discussed.

  3. All-IP-Ethernet architecture for real-time sensor-fusion processing

    Science.gov (United States)

    Hiraki, Kei; Inaba, Mary; Tezuka, Hiroshi; Tomari, Hisanobu; Koizumi, Kenichi; Kondo, Shuya

    2016-03-01

    Serendipter is a device that distinguishes and selects very rare particles and cells from huge amount of population. We are currently designing and constructing information processing system for a Serendipter. The information processing system for Serendipter is a kind of sensor-fusion system but with much more difficulties: To fulfill these requirements, we adopt All IP based architecture: All IP-Ethernet based data processing system consists of (1) sensor/detector directly output data as IP-Ethernet packet stream, (2) single Ethernet/TCP/IP streams by a L2 100Gbps Ethernet switch, (3) An FPGA board with 100Gbps Ethernet I/F connected to the switch and a Xeon based server. Circuits in the FPGA include 100Gbps Ethernet MAC, buffers and preprocessing, and real-time Deep learning circuits using multi-layer neural networks. Proposed All-IP architecture solves existing problem to construct large-scale sensor-fusion systems.

  4. Astronomy all the time for everybody

    Science.gov (United States)

    Grigore, Valentin

    2015-08-01

    General contextCommunicating astronomy with the public must be done all year and with all community members using all the available methods to promote the all aspects of astronomy: education, science, research, new technologies, dark-sky protection, astrophotography, mythology, astropoetry, astro arts and music.An annual calendarTwo aspect must be taken in consideration when create a calendar of activity:- astronomical events (eclipses, meteor showers, comets, etc.)- international and local astronomical events: Global Astronomy Months, Astronomy Day, Globe at Night, ISAN, public activitiesCommunicating astronomy with the whole communityA description of the experience of the author organizing over 500 events in 30 years of activity including all the community members: general public, students, teachers, artists, authorities, people with disabilities, minor and adult prisoners, etc.An experience of seven years as TV producer of the astronomy TV show “Ùs and the Sky” is presented.Promotion of the activityThe relation with the mass-media is an important aspect communicating astronomy with the public.Mass-media between rating and correct information of the public.The role of the cooperation with the community in astronomy projectsA successful model: EURONEAR project

  5. Timing Comparisons for GLEs and High-energy Proton Events using GPS Proton Measurements

    Science.gov (United States)

    Bernstein, V.; Winter, L. M.; Carver, M.; Morley, S.

    2017-12-01

    The newly released LANL GPS particle sensor data offers a unique snapshot of access of relativistic particles into the geomagnetic field. Currently, 23 of the 31 operational GPS satellites host energetic particle detectors which can detect the arrival of high-energy solar protons associated with Ground Level Enhancements (GLEs). We compare the timing profiles of solar energetic proton detections from GPS satellites as well as from ground-based Neutron Monitors and GOES spacecraft at geostationary orbit in order to understand how high-energy protons from the Sun enter the geomagnetic field and investigate potential differences in arrival time of energetic protons at GPS satellites as a function of location. Previous studies could only use one or two spacecraft at a similar altitude to track the arrival of energetic particles. With GPS data, we can now test whether the particles arrive isotropically, as assumed, or whether there exist differences in the timing and energetics viewed by each of the individual satellites. Extensions of this work could lead to improvements in space weather forecasting that predict more localized risk estimates for space-based technology.

  6. 77 FR 70176 - Previous Participation Certification

    Science.gov (United States)

    2012-11-23

    ... participants' previous participation in government programs and ensure that the past record is acceptable prior... information is designed to be 100 percent automated and digital submission of all data and certifications is... government programs and ensure that the past record is acceptable prior to granting approval to participate...

  7. High speed all optical networks

    Science.gov (United States)

    Chlamtac, Imrich; Ganz, Aura

    1990-01-01

    An inherent problem of conventional point-to-point wide area network (WAN) architectures is that they cannot translate optical transmission bandwidth into comparable user available throughput due to the limiting electronic processing speed of the switching nodes. The first solution to wavelength division multiplexing (WDM) based WAN networks that overcomes this limitation is presented. The proposed Lightnet architecture takes into account the idiosyncrasies of WDM switching/transmission leading to an efficient and pragmatic solution. The Lightnet architecture trades the ample WDM bandwidth for a reduction in the number of processing stages and a simplification of each switching stage, leading to drastically increased effective network throughputs. The principle of the Lightnet architecture is the construction and use of virtual topology networks, embedded in the original network in the wavelength domain. For this construction Lightnets utilize the new concept of lightpaths which constitute the links of the virtual topology. Lightpaths are all-optical, multihop, paths in the network that allow data to be switched through intermediate nodes using high throughput passive optical switches. The use of the virtual topologies and the associated switching design introduce a number of new ideas, which are discussed in detail.

  8. Gene Duplicability of Core Genes Is Highly Consistent across All Angiosperms.

    Science.gov (United States)

    Li, Zhen; Defoort, Jonas; Tasdighian, Setareh; Maere, Steven; Van de Peer, Yves; De Smet, Riet

    2016-02-01

    Gene duplication is an important mechanism for adding to genomic novelty. Hence, which genes undergo duplication and are preserved following duplication is an important question. It has been observed that gene duplicability, or the ability of genes to be retained following duplication, is a nonrandom process, with certain genes being more amenable to survive duplication events than others. Primarily, gene essentiality and the type of duplication (small-scale versus large-scale) have been shown in different species to influence the (long-term) survival of novel genes. However, an overarching view of "gene duplicability" is lacking, mainly due to the fact that previous studies usually focused on individual species and did not account for the influence of genomic context and the time of duplication. Here, we present a large-scale study in which we investigated duplicate retention for 9178 gene families shared between 37 flowering plant species, referred to as angiosperm core gene families. For most gene families, we observe a strikingly consistent pattern of gene duplicability across species, with gene families being either primarily single-copy or multicopy in all species. An intermediate class contains gene families that are often retained in duplicate for periods extending to tens of millions of years after whole-genome duplication, but ultimately appear to be largely restored to singleton status, suggesting that these genes may be dosage balance sensitive. The distinction between single-copy and multicopy gene families is reflected in their functional annotation, with single-copy genes being mainly involved in the maintenance of genome stability and organelle function and multicopy genes in signaling, transport, and metabolism. The intermediate class was overrepresented in regulatory genes, further suggesting that these represent putative dosage-balance-sensitive genes. © 2016 American Society of Plant Biologists. All rights reserved.

  9. Does previous abdominal surgery affect the course and outcomes of laparoscopic bariatric surgery?

    Science.gov (United States)

    Major, Piotr; Droś, Jakub; Kacprzyk, Artur; Pędziwiatr, Michał; Małczak, Piotr; Wysocki, Michał; Janik, Michał; Walędziak, Maciej; Paśnik, Krzysztof; Hady, Hady Razak; Dadan, Jacek; Proczko-Stepaniak, Monika; Kaska, Łukasz; Lech, Paweł; Michalik, Maciej; Duchnik, Michał; Kaseja, Krzysztof; Pastuszka, Maciej; Stepuch, Paweł; Budzyński, Andrzej

    2018-03-26

    Global experiences in general surgery suggest that previous abdominal surgery may negatively influence different aspects of perioperative care. As the incidence of bariatric procedures has recently increased, it is essential to assess such correlations in bariatric surgery. To assess whether previous abdominal surgery influences the course and outcomes of laparoscopic bariatric surgery. Seven referral bariatric centers in Poland. We conducted a retrospective analysis of 2413 patients; 1706 patients who underwent laparoscopic sleeve gastrectomy (SG) or Roux-en-Y gastric bypass (RYGB) matched the inclusion criteria. Patients with no history of abdominal surgery were included as group 1, while those who had undergone at least 1 abdominal surgery were included as group 2. Group 2 had a significantly prolonged median operation time for RYGB (P = .012), and the longest operation time was observed in patients who had previously undergone surgeries in both the upper and lower abdomen (P = .002). Such a correlation was not found in SG cases (P = .396). Groups 1 and 2 had similar rates of intraoperative adverse events and postoperative complications (P = .562 and P = .466, respectively). Group 2 had a longer median duration of hospitalization than group 1 (P = .034), while the readmission rate was similar between groups (P = .079). There was no significant difference between groups regarding the influence of the long-term effects of bariatric treatment on weight loss (percentage of follow-up was 55%). Previous abdominal surgery prolongs the operative time of RYGB and the duration of postoperative hospitalization, but does not affect the long-term outcomes of bariatric treatment. Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  10. High Reversibility of Soft Electrode Materials in All-solid-state Batteries

    Directory of Open Access Journals (Sweden)

    Atsushi eSakuda

    2016-05-01

    Full Text Available All-solid-state batteries using inorganic solid electrolytes (SEs are considered to be ideal batteries for electric vehicles (EVs and plug-in hybrid electric vehicles (PHEVs because they are potentially safer than conventional lithium-ion batteries (LIBs. In addition, all-solid-state batteries are expected to have long battery lives owing to the inhibition of chemical side reactions because only lithium ions move through the typically used inorganic SEs. The development of high-energy (more than 300 Wh kg-1 secondary batteries has been eagerly anticipated for years. The application of high-capacity electrode active materials is essential for fabricating such batteries. Recently, we proposed metal polysulfides as new electrode materials. These materials show higher conductivity and density than sulfur, which is advantageous for fabricating batteries with relatively higher energy density. Lithium niobium sulfides, such as Li3NbS4, have relatively high density, conductivity, and rate capability among metal polysulfide materials, and batteries with these materials have capacities high enough to potentially exceed the gravimetric energy density of conventional LIBs.Favorable solid-solid contact between the electrode and electrolyte particles is a key factor for fabricating high performance all-solid-state batteries. Conventional oxide-based positive electrode materials tend to be given rise to cracks during fabrication and/or charge-discharge processes. Here we report all-solid-state cells using lithium niobium sulfide as a positive electrode material, where favorable solid-solid contact was established by using lithium sulfide electrode materials because of their high processability. Cracks were barely observed in the electrode particles in the all-solid-state cells before or after charging and discharging with a high capacity of approx. 400 mAh g-1, suggesting that the lithium niobium sulfide electrode charged and discharged without experiencing

  11. High-density housing that works for all

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, Arif

    2010-03-15

    In an urbanising world, the way people fit into cities is vastly important - socially, economically, environmentally, even psychologically. So density, or the number of people living in a given area, is central to urban design and planning. Both governments and markets tend to get density wrong, leading to overcrowding, urban sprawl or often both. A case in point are the high-rise buildings springing up throughtout urban Asia - perceived as key features of that widely touted concept, the 'world-class city'. While some may offer a viable solution to land pressures and density requirements, many built to house evicted or resettled 'slum' dwellers are a social and economic nightmare - inconveniently sited, overcrowded and costly. New evidence from Karachi, Pakistan, reveals a real alternative. Poor people can create liveable high-density settlements as long as community control, the right technical assistance and flexible designs are in place. A city is surely 'world-class' only when it is cosmopolitan – built to serve all, including the poorest.

  12. Large-scale micromagnetics simulations with dipolar interaction using all-to-all communications

    Directory of Open Access Journals (Sweden)

    Hiroshi Tsukahara

    2016-05-01

    Full Text Available We implement on our micromagnetics simulator low-complexity parallel fast-Fourier-transform algorithms, which reduces the frequency of all-to-all communications from six to two times. Almost all the computation time of micromagnetics simulation is taken up by the calculation of the magnetostatic field which can be calculated using the fast Fourier transform method. The results show that the simulation time is decreased with good scalability, even if the micromagentics simulation is performed using 8192 physical cores. This high parallelization effect enables large-scale micromagentics simulation using over one billion to be performed. Because massively parallel computing is needed to simulate the magnetization dynamics of real permanent magnets composed of many micron-sized grains, it is expected that our simulator reveals how magnetization dynamics influences the coercivity of the permanent magnet.

  13. Proteomics analysis in frozen horse mackerel previously high-pressure processed.

    Science.gov (United States)

    Pazos, Manuel; Méndez, Lucía; Vázquez, Manuel; Aubourg, Santiago P

    2015-10-15

    The effect of high-pressure processing (HPP) (150, 300 and 450 MPa for 0, 2.5 and 5 min) on total sodium dodecyl sulphate (SDS)-soluble and sarcoplasmic proteins in frozen (-10 °C for 3 months) horse mackerel (Trachurus trachurus) was evaluated. Proteomics tools based on image analysis of SDS-PAGE protein gels and protein identification by tandem mass spectrometry (MS/MS) were applied. Although total SDS-soluble fraction indicated no important changes induced by HPP, this processing modified the 1-D SDS-PAGE sarcoplasmic patterns in a direct-dependent manner and exerted a selective effect on particular proteins depending on processing conditions. Thus, application of the highest pressure (450 MPa) provoked a significant degradation of phosphoglycerate mutase 2, glycogen phosphorylase muscle form, pyruvate kinase muscle isozyme, beta-enolase and triosephosphate isomerase and phosphoglucomutase-1. Conversely, protein bands assigned to tropomyosin alpha-1 chain, fast myotomal muscle troponin T and parvalbumin beta 2 increased their intensity after applying a 450-MPa processing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Reduced timing Sensitivity in all-optical switching using flat-top control pulses obtained by the optical fourier transform technique

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Galili, Michael; Mulvad, Hans Christian Hansen

    2006-01-01

    into the time domain, referred to as the optical Fourier transform technique. A 3 ps flat-top pulse derived from a 3 nm wide square filter is obtained, and used to gate an all-optical OTDM demultiplexer, yielding an error-free timing jitter tolerance of 3 ps for 80 Gb/s and 160 Gb/s data signals.......For high-speed serial data, timing tolerance is crucial for switching and regeneration. We propose a novel scheme to generate flat-top pulses, for use as gating control pulses. The scheme relies on spectral shaping by a square-shaped filter, followed by a linear transformation of the spectral shape...

  15. High resolution distributed time-to-digital converter (TDC) in a White Rabbit network

    International Nuclear Information System (INIS)

    Pan, Weibin; Gong, Guanghua; Du, Qiang; Li, Hongming; Li, Jianmin

    2014-01-01

    The Large High Altitude Air Shower Observatory (LHAASO) project consists of a complex detector array with over 6000 detector nodes spreading over 1.2 km 2 areas. The arrival times of shower particles are captured by time-to-digital converters (TDCs) in the detectors' frontend electronics, the arrival direction of the high energy cosmic ray are then to be reconstructed from the space-time information of all detector nodes. To guarantee the angular resolution of 0.5°, a time synchronization of 500 ps (RMS) accuracy and 100 ps precision must be achieved among all TDC nodes. A technology enhancing Gigabit Ethernet, called the White Rabbit (WR), has shown the capability of delivering sub-nanosecond accuracy and picoseconds precision of synchronization over the standard data packet transfer. In this paper we demonstrate a distributed TDC prototype system combining the FPGA based TDC and the WR technology. With the time synchronization and data transfer services from a compact WR node, separate FPGA-TDC nodes can be combined to provide uniform time measurement information for correlated events. The design detail and test performance will be described in the paper

  16. High resolution distributed time-to-digital converter (TDC) in a White Rabbit network

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Weibin, E-mail: pwb.thu@gmail.com; Gong, Guanghua; Du, Qiang; Li, Hongming; Li, Jianmin

    2014-02-21

    The Large High Altitude Air Shower Observatory (LHAASO) project consists of a complex detector array with over 6000 detector nodes spreading over 1.2 km{sup 2} areas. The arrival times of shower particles are captured by time-to-digital converters (TDCs) in the detectors' frontend electronics, the arrival direction of the high energy cosmic ray are then to be reconstructed from the space-time information of all detector nodes. To guarantee the angular resolution of 0.5°, a time synchronization of 500 ps (RMS) accuracy and 100 ps precision must be achieved among all TDC nodes. A technology enhancing Gigabit Ethernet, called the White Rabbit (WR), has shown the capability of delivering sub-nanosecond accuracy and picoseconds precision of synchronization over the standard data packet transfer. In this paper we demonstrate a distributed TDC prototype system combining the FPGA based TDC and the WR technology. With the time synchronization and data transfer services from a compact WR node, separate FPGA-TDC nodes can be combined to provide uniform time measurement information for correlated events. The design detail and test performance will be described in the paper.

  17. High school start times after 8:30 am are associated with later wake times and longer time in bed among teens in a national urban cohort study.

    Science.gov (United States)

    Nahmod, Nicole G; Lee, Soomi; Buxton, Orfeu M; Chang, Anne-Marie; Hale, Lauren

    2017-12-01

    High school start times are a key contributor to insufficient sleep. This study investigated associations of high school start times with bedtime, wake time, and time in bed among urban teenagers. Daily-diary study nested within the prospective Fragile Families and Child Wellbeing Study. Twenty US cities. Four hundred thirteen teenagers who completed ≥1 daily diary report on a school day. Participating teens were asked to complete daily diaries for 7 consecutive days. School-day daily diaries (3.8±1.6 entries per person) were used in analyses (N=1555 school days). High school start time, the main predictor, was categorized as 7:00-7:29 am (15%), 7:30-7:59 am (22%), 8:00-8:29 am (35%), and 8:30 am or later (28%). Multilevel modeling examined the associations of school start times with bedtime, wake time, and time in bed. Models adjusted for age, sex, race/ethnicity, household income, caregiver's education, and school type. Teens with the earliest high school start times (7:00-7:29 am) obtained 46 minutes less time in bed on average compared with teens with high school start times at 8:30 am or later (Pstart times and shorter time in bed, primarily due to earlier wake times (PStart times after 8:30 am were associated with increased time in bed, extending morning sleep by 27-57 minutes (Pstart times. Later school start times are associated with later wake times in our large, diverse sample. Teens starting school at 8:30 am or later are the only group with an average time in bed permitting 8 hours of sleep, the minimum recommended by expert consensus for health and well-being. Copyright © 2017 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  18. All-Optical Ultra-High-Speed OFDM to Nyquist-WDM Conversion Based on Complete Optical Fourier Transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Mulvad, Hans Christian Hansen

    2016-01-01

    We propose a novel all-optical ultra-high-speed orthogonal frequency-division multiplexing (OFDM) to Nyquist wavelength-division multiplexing (Nyquist-WDM) conversion scheme, achieved by exchanging the temporal and spectral profiles using a complete optical Fourier transformation (OFT). This scheme...... enables high-speed OFDM to Nyquist-WDM conversion without complex optical/electrical/optical conversion. The all-optical OFDM transmitter is based on the generation of OFDM symbols with a low duty cycle by rectangular temporal gating, which in combination with optical time-division multiplexing yields...... a higher symbol-rate OFDM signal. In the receiver, the converted Nyquist-WDM super-channel is WDM demultiplexed into individual Nyquist-WDM channels using a rectangular optical bandpass filter, followed by optical sampling at the intersymbol-interference free point. In the experimental demonstration...

  19. Real-time, adaptive machine learning for non-stationary, near chaotic gasoline engine combustion time series.

    Science.gov (United States)

    Vaughan, Adam; Bohac, Stanislav V

    2015-10-01

    Fuel efficient Homogeneous Charge Compression Ignition (HCCI) engine combustion timing predictions must contend with non-linear chemistry, non-linear physics, period doubling bifurcation(s), turbulent mixing, model parameters that can drift day-to-day, and air-fuel mixture state information that cannot typically be resolved on a cycle-to-cycle basis, especially during transients. In previous work, an abstract cycle-to-cycle mapping function coupled with ϵ-Support Vector Regression was shown to predict experimentally observed cycle-to-cycle combustion timing over a wide range of engine conditions, despite some of the aforementioned difficulties. The main limitation of the previous approach was that a partially acasual randomly sampled training dataset was used to train proof of concept offline predictions. The objective of this paper is to address this limitation by proposing a new online adaptive Extreme Learning Machine (ELM) extension named Weighted Ring-ELM. This extension enables fully causal combustion timing predictions at randomly chosen engine set points, and is shown to achieve results that are as good as or better than the previous offline method. The broader objective of this approach is to enable a new class of real-time model predictive control strategies for high variability HCCI and, ultimately, to bring HCCI's low engine-out NOx and reduced CO2 emissions to production engines. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Time lens for high-resolution neutron time-of-flight spectrometers

    International Nuclear Information System (INIS)

    Baumann, K.; Gaehler, R.; Grigoriev, P.; Kats, E.I.

    2005-01-01

    We examine in analytic and numeric ways the imaging effects of temporal neutron lenses created by traveling magnetic fields. For fields of parabolic shape we derive the imaging equations, investigate the time magnification, the evolution of the phase-space element, the gain factor, and the effect of finite beam size. The main aberration effects are calculated numerically. The system is technologically feasible and should convert neutron time-of-flight instruments from pinhole to imaging configuration in time, thus enhancing intensity and/or time resolution. Further fields of application for high-resolution spectrometry may be opened

  1. Usability of a new multiple high-speed pulse time data registration, processing and real-time display system for pulse time interval analysis

    International Nuclear Information System (INIS)

    Yawata, Takashi; Sakaue, Hisanobu; Hashimoto, Tetsuo; Itou, Shigeki

    2006-01-01

    A new high-speed multiple pulse time data registration, processing and real-time display system for time interval analysis (TIA) was developed for counting either β-α or α-α correlated decay-events. The TIA method has been so far limited to selective extraction of successive α-α decay events within the milli-second time scale owing to the use of original electronic hardware. In the present pulse-processing system, three different high-speed α/β(γ) pulses could be fed quickly to original 32 bit PCI board (ZN-HTS2) within 1 μs. This original PCI board is consisting of a timing-control IC (HTS-A) and 28 bit counting IC (HTS-B). All channel and pulse time data were stored to FIFO RAM, followed to transfer into temporary CPU RAM (32 MB) by DMA. Both data registration (into main RAM (200 MB)) and calculation of pulse time intervals together with real-time TIA-distribution display simultaneously processed using two sophisticate softwares. The present system has proven to succeed for the real-time display of TIA distribution spectrum even when 1.6x10 5 cps pulses from pulse generator were given to the system. By using this new system combined with liquid scintillation counting (LSC) apparatus, both a natural micro-second order β-α correlated decay-events and a milli-second order α-α correlated decay-event could be selectively extracted from the mixture of natural radionuclides. (author)

  2. A High Granularity Timing Detector for the ATLAS Experiment at LHC, CERN

    CERN Document Server

    Mallik, Usha; The ATLAS collaboration

    2018-01-01

    A High Granularity Timing Detector of ~30 psec resolution is undertaken by the ATLAS Collaboration for the Phase-II hi-luminosity upgrade, where a pile-up of up to 200 is expected. To improve the overall discriminating ability for the hard scattering events, the additional dimension of precise timing is used in conjunction with the precision position measurements of the Inner Tracking Detectors at high pseudorapidity. The overall effect is to be able to make effective use of the higher beam intensities. Very good progress has been achieved thus far in all aspects; these are discussed with future milestones.

  3. Time-resolved x-ray diffraction analysis of the experimental dehydration of serpentine at high pressure

    International Nuclear Information System (INIS)

    Inoue, Toru; Yoshimi, Isamu; Yamada, Akihiro; Kikegawa, Takumi

    2009-01-01

    Time-resolved, in situ X-ray diffraction analysis was used to determine the dehydration rate and kinetics of serpentine during experimental dehydration at high pressures. The capsule used comprises a diamond sleeve fitted with Au or Pt lids in order to provide high-quality, time-resolved X-ray diffraction data. Antigorite quickly dehydrated to enstatite + forsterite + fluid within 2 h at 650degC below ∼6 GPa. Avrami modeling of the results and SEM observations of the partially dehydrated sample revealed that the nucleation rate was quite high for enstatite but low for forsterite, showing incubation periods of ∼10 min before appearing. The crystallization of these minerals is controlled largely by the composition of the fluid generated from serpentine dehydration. The dehydration boundary determined below 6 GPa in the present study is consistent with the results of previous phase equilibrium studies. This study indicates that serpentine in a subducting slab dehydrates rapidly below 6 GPa when the slab intersects the dehydration boundary conditions. (author)

  4. New design for photonic temporal integration with combined high processing speed and long operation time window.

    Science.gov (United States)

    Asghari, Mohammad H; Park, Yongwoo; Azaña, José

    2011-01-17

    We propose and experimentally prove a novel design for implementing photonic temporal integrators simultaneously offering a high processing bandwidth and a long operation time window, namely a large time-bandwidth product. The proposed scheme is based on concatenating in series a time-limited ultrafast photonic temporal integrator, e.g. implemented using a fiber Bragg grating (FBG), with a discrete-time (bandwidth limited) optical integrator, e.g. implemented using an optical resonant cavity. This design combines the advantages of these two previously demonstrated photonic integrator solutions, providing a processing speed as high as that of the time-limited ultrafast integrator and an operation time window fixed by the discrete-time integrator. Proof-of-concept experiments are reported using a uniform fiber Bragg grating (as the original time-limited integrator) connected in series with a bulk-optics coherent interferometers' system (as a passive 4-points discrete-time photonic temporal integrator). Using this setup, we demonstrate accurate temporal integration of complex-field optical signals with time-features as fast as ~6 ps, only limited by the processing bandwidth of the FBG integrator, over time durations as long as ~200 ps, which represents a 4-fold improvement over the operation time window (~50 ps) of the original FBG integrator.

  5. Time Lens based Optical Fourier Transformation for All-Optical Signal Processing of Spectrally-Efficient Data

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Lillieholm, Mads

    2017-01-01

    We review recent progress in the use of time lens based optical Fourier transformation for advanced all-optical signal processing. A novel time lens based complete optical Fourier transformation (OFT) technique is introduced. This complete OFT is based on two quadratic phase-modulation stages using...... four-wave mixing (FWM), separated by a dispersive medium, which enables time-to-frequency and frequency-to-time conversions simultaneously, thus performing an exchange between the temporal and spectral profiles of the input signal. Using the proposed complete OFT, several advanced all-optical signal......, such as orthogonal frequency division multiplexing (OFDM), Nyquist wavelength-division multiplexing (Nyquist-WDM) and Nyquist optical time division multiplexing (Nyquist-OTDM) signals....

  6. Evaluation of highly accelerated real-time cardiac cine MRI in tachycardia.

    Science.gov (United States)

    Bassett, Elwin C; Kholmovski, Eugene G; Wilson, Brent D; DiBella, Edward V R; Dosdall, Derek J; Ranjan, Ravi; McGann, Christopher J; Kim, Daniel

    2014-02-01

    Electrocardiogram (ECG)-gated breath-hold cine MRI is considered to be the gold standard test for the assessment of cardiac function. However, it may fail in patients with arrhythmia, impaired breath-hold capacity and poor ECG gating. Although ungated real-time cine MRI may mitigate these problems, commercially available real-time cine MRI pulse sequences using parallel imaging typically yield relatively poor spatiotemporal resolution because of their low image acquisition efficiency. As an extension of our previous work, the purpose of this study was to evaluate the diagnostic quality and accuracy of eight-fold-accelerated real-time cine MRI with compressed sensing (CS) for the quantification of cardiac function in tachycardia, where it is challenging for real-time cine MRI to provide sufficient spatiotemporal resolution. We evaluated the performances of eight-fold-accelerated cine MRI with CS, three-fold-accelerated real-time cine MRI with temporal generalized autocalibrating partially parallel acquisitions (TGRAPPA) and ECG-gated breath-hold cine MRI in 21 large animals with tachycardia (mean heart rate, 104 beats per minute) at 3T. For each cine MRI method, two expert readers evaluated the diagnostic quality in four categories (image quality, temporal fidelity of wall motion, artifacts and apparent noise) using a Likert scale (1-5, worst to best). One reader evaluated the left ventricular functional parameters. The diagnostic quality scores were significantly different between the three cine pulse sequences, except for the artifact level between CS and TGRAPPA real-time cine MRI. Both ECG-gated breath-hold cine MRI and eight-fold accelerated real-time cine MRI yielded all four scores of ≥ 3.0 (acceptable), whereas three-fold-accelerated real-time cine MRI yielded all scores below 3.0, except for artifact (3.0). The left ventricular ejection fraction (LVEF) measurements agreed better between ECG-gated cine MRI and eight-fold-accelerated real-time cine MRI

  7. Time-dose relationship of erythema in high energy photon irradiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hidetoshi (Gifu Prefectural Tajimi Hospital (Japan)); Sakuma, Sadayuki

    1992-01-01

    Skin doses of 100 patients who were treated with high energy ionizing irradiation during conventional irradiation therapy were measured by thermoluminescence dosimeter (TLD). In 87 of the 100 patients, acute hyperemic change of the skin (erythema) of the irradiated region was observed. In the other 13 patients, alopetia of the scalp was observed. The following conclusions were reached. The time-dose relationship was linear when erythema tolerance was used as an index, but not when alopecia was used. The tolerance dose for erythema was lower than previously reported. The slope of the isoeffect curve on the log-log plot of total absorbed skin dose against total number of days after the first irradiation was 0.68 when erythema was used as an index. This number is larger than previously reported results. We considered that erythema is significantly influenced by fraction size and that hyperfractionation is a promising method of irradiation, especially in Japan. Combined use of chemotherapeutic agents, such as 5-FU, accelerated erythema. The slope of combined treatment was 0.86. Observing acute hyperemic change of skin is considered to be a useful method of investigating the combined effects of chemotherapeutic agents on irradiation. (author).

  8. A digital approach for real time high-rate high-resolution radiation measurements

    International Nuclear Information System (INIS)

    Gerardi, G.; Abbene, L.

    2014-01-01

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  9. A digital approach for real time high-rate high-resolution radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, G.; Abbene, L., E-mail: leonardo.abbene@unipa.it

    2014-12-21

    Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted through both theoretical and experimental approaches. To strengthen our approach, the implementation of the method on a real-time system together with some experimental results are presented. X-ray spectra measurements with a semiconductor detector are performed both at low and high photon counting rates (up to 1.1 Mcps)

  10. Relaxation Time of High-Density Amorphous Ice

    Science.gov (United States)

    Handle, Philip H.; Seidl, Markus; Loerting, Thomas

    2012-06-01

    Amorphous water plays a fundamental role in astrophysics, cryoelectron microscopy, hydration of matter, and our understanding of anomalous liquid water properties. Yet, the characteristics of the relaxation processes taking place in high-density amorphous ice (HDA) are unknown. We here reveal that the relaxation processes in HDA at 110-135 K at 0.1-0.2 GPa are of collective and global nature, resembling the alpha relaxation in glassy material. Measured relaxation times suggest liquid-like relaxation characteristics in the vicinity of the crystallization temperature at 145 K. By carefully relaxing pressurized HDA for several hours at 135 K, we produce a state that is closer to the ideal glass state than all HDA states discussed so far in literature.

  11. Semiconductor optical amplifier-based all-optical gates for high-speed optical processing

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    2000-01-01

    Semiconductor optical amplifiers are useful building blocks for all-optical gates as wavelength converters and OTDM demultiplexers. The paper reviews the progress from simple gates using cross-gain modulation and four-wave mixing to the integrated interferometric gates using cross-phase modulation....... These gates are very efficient for high-speed signal processing and open up interesting new areas, such as all-optical regeneration and high-speed all-optical logic functions...

  12. Prediction of successful trial of labour in patients with a previous caesarean section

    International Nuclear Information System (INIS)

    Shaheen, N.; Khalil, S.; Iftikhar, P.

    2014-01-01

    Objective: To determine the prediction rate of success in trial of labour after one previous caesarean section. Methods: The cross-sectional study was conducted at the Department of Obstetrics and Gynaecology, Cantonment General Hospital, Rawalpindi, from January 1, 2012 to January 31, 2013, and comprised women with one previous Caesarean section and with single alive foetus at 37-41 weeks of gestation. Women with more than one Caesarean section, unknown site of uterine scar, bony pelvic deformity, placenta previa, intra-uterine growth restriction, deep transverse arrest in previous labour and non-reassuring foetal status at the time of admission were excluded. Intrapartum risk assessment included Bishop score at admission, rate of cervical dilatation and scar tenderness. SPSS 21 was used for statistical analysis. Results: Out of a total of 95 women, the trial was successful in 68 (71.6%). Estimated foetal weight and number of prior vaginal deliveries had a high predictive value for successful trial of labour after Caesarean section. Estimated foetal weight had an odds ratio of 0.46 (p<0.001), while number of prior vaginal deliveries had an odds ratio of 0.85 with (p=0.010). Other factors found to be predictive of successful trial included Bishop score at the time of admission (p<0.037) and rate of cervical dilatation in the first stage of labour (p<0.021). Conclusion: History of prior vaginal deliveries, higher Bishop score at the time of admission, rapid rate of cervical dilatation and lower estimated foetal weight were predictive of a successful trial of labour after Caesarean section. (author)

  13. [Comparison of the present and previously used protocol of risk stratification in children with acute lymphoblastic leukemia].

    Science.gov (United States)

    Glodkowska, Eliza; Bialas, Agnieszka; Jackowska, Teresa

    2007-01-01

    Acute lymphoblastic leukaemia (ALL) is one of the most common cancers in children. In Poland, since November 2002 a new protocol of risk stratification has been recommended for assessment of risk factors and for choosing therapy regimens. assessment of accuracy of protocol ALL-IC 2002 in comparison to previously used risk stratification protocols. ALL was diagnosed in 100 children (44 girls, 56 boys; 1-18 years of age) in the Department of Pediatric Hematology and Oncology, Warsaw Medical University, over the period from November 2002 to November 2006. According to the ALL-IC 2002 protocol the patients were divided into three risk groups: SR-standard, IR-intermediate and HR-high. The stratification was by age, leukocyte count, cytogenetic changes, early response to prednisone therapy and bone marrow remission. In the previously used risk stratification protocols-BFM-90, only hepatosplenomegaly and the number of blasts in peripheral blood (PB) were considered, and the patients were divided into three risk groups: low (LRG1.2). out of the 100 patients qualified for treatment regimens according to the ALL-IC 2002 protocol, 97 entered remission, 11 died and 3 had a relapse. Under the ALL-IC 2002 protocol these children were stratified into the following groups: SR-31%, IR-44% and HR-25%. In the previously used stratification, there would be 26% children in low, 46% in the medium and 28% in the high risk group. According to the BFM-90 protocol 18/31 (58%) and 16/44 (36%) patients from the SR and IR groups respectively would be given more intensive treatment. On the other hand 11/44 (25%) and 14/25 (56%) patients from the IR and HR groups respectively would be given less intensive treatment. 1. ALL-IC 2002 protocol in comparison with the previously used protocol BFM-90, changes the qualification of children with ALL for the SR, IR and HR risk groups. This is linked to basic change of treatment protocol, adequate to severity of disease. 2. Children with ALL qualified

  14. Optical timing receiver for the NASA Spaceborne Ranging System. Part II: high precision event-timing digitizer

    Energy Technology Data Exchange (ETDEWEB)

    Leskovar, Branko; Turko, Bojan

    1978-08-01

    Position-resolution capabilities of the NASA Spaceborne Laser Ranging System are essentially determined by the timeresolution capabilities of its optical timing receiver. The optical timing receiver consists of a fast photoelectric device; (e.g., photomultiplier or an avalanche photodiode detector), a timing discriminator, a high-precision event-timing digitizer, and a signal-processing system. The time-resolution capabilities of the receiver are determined by the photoelectron time spread of the photoelectric device, the time walk and resolution characteristics of the timing discriminator, and the resolution of the event-timing digitizer. It is thus necessary to evaluate available fast photoelectronic devices with respect to the time-resolution capabilities, and to develop a very low time walk timing discriminator and a high-resolution event-timing digitizer to be used in the high-resolution spaceborne laser ranging system receiver. This part of the report describes the development of a high precision event-timing digitizer. The event-timing digitizer is basically a combination of a very accurate high resolution real time digital clock and an interval timer. The timing digitizer is a high resolution multiple stop clock, counting the time up to 131 days in 19.5 ps increments.

  15. Being prepared on time: On the importance of the previous foreperiod on current preparation, as reflected in speed force and preparation-related brain potentials.

    NARCIS (Netherlands)

    Van der Lubbe, R.H.J.; Los, S.A.; Jaskowski, P.; Verleger, R.

    2004-01-01

    How do participants adapt to temporal variation of preparatory foreperiods? For reaction times, specific sequential effects have been observed. Responses become slower when the foreperiod is shorter on the current than on the previous trial. If this effect is due to changes in motor activation, it

  16. Being prepared on time: on the importance of the previous foreperiod to current preparation, as reflected in speed, force and preparation-related brain potentials

    NARCIS (Netherlands)

    van der Lubbe, Robert Henricus Johannes; Los, Sander A.; Jaśkowski, Piotr; Verleger, Rolf

    2004-01-01

    How do participants adapt to temporal variation of preparatory foreperiods? For reaction times, specific sequential effects have been observed. Responses become slower when the foreperiod is shorter on the current than on the previous trial. If this effect is due to changes in motor activation, it

  17. All-sky search for high-energy neutrinos from gravitational wave event GW170104 with the Antares neutrino telescope

    International Nuclear Information System (INIS)

    Albert, A.; Drouhin, D.; Racca, C.; Andre, M.; Anghinolfi, M.; Anton, G.; Eberl, T.; Graf, K.; Hallmann, S.; Hoessl, J.; Hofestaedt, J.; James, C.W.; Kalekin, O.; Katz, U.; Kiessling, D.; Lahmann, R.; Sieger, C.; Ardid, M.; Felis, I.; Martinez-Mora, J.A.; Saldana, M.; Aubert, J.J.; Bertin, V.; Brunner, J.; Busto, J.; Carr, J.; Costantini, H.; Coyle, P.; Dornic, D.; Enzenhoefer, A.; Quinn, L.; Salvadori, I.; Turpin, D.; Avgitas, T.; Baret, B.; Bourret, S.; Coelho, J.A.B.; Creusot, A.; Gregoire, T.; Gracia Ruiz, R.; Lachaud, C.; Barrios-Marti, J.; Hernandez-Rey, J.J.; Illuminati, G.; Lotze, M.; Toennis, C.; Zornoza, J.D.; Zuniga, J.; Basa, S.; Marcelin, M.; Nezri, E.; Belhorma, B.; Biagi, S.; Coniglione, R.; Distefano, C.; Piattelli, P.; Riccobene, G.; Sapienza, P.; Trovato, A.; Bormuth, R.; Jong, M. de; Samtleben, D.F.E.; Bouwhuis, M.C.; Heijboer, A.J.; Jongen, M.; Michael, T.; Branzas, H.; Caramete, L.; Pavalas, G.E.; Popa, V.; Bruijn, R.; Melis, K.; Capone, A.; Di Palma, I.; Perrina, C.; Vizzoca, A.; Celli, S.; Cherkaoui El Moursli, R.; El Khayati, N.; Ettahiri, A.; Fassi, F.; Tayalati, Y.; Chiarusi, T.; Circella, M.; Sanchez-Losa, A.; Coleiro, A.; Diaz, A.F.; Deschamps, A.; Hello, Y.; De Bonis, G.; Domi, A.; Hugon, C.; Sanguineti, M.; Taiuti, M.; Donzaud, C.; El Bojaddaini, I.; Moussa, A.; Elsaesser, D.; Kadler, M.; Kreter, M.; Fusco, L.A.; Margiotta, A.; Pellegrino, C.; Spurio, M.; Versari, F.; Gay, P.; Giordano, V.; Glotin, H.; Haren, H. van; Kouchner, A.; Van Elewyck, V.; Kreykenbohm, I.; Wilms, J.; Kulikovskiy, V.; Lefevre, D.; Leonora, E.; Loucatos, S.; Vallage, B.; Marinelli, A.; Mele, R.; Vivolo, D.; Migliozzi, P.; Navas, S.; Organokov, M.; Pradier, T.; Schuessler, F.; Stolarczyk, T.

    2017-01-01

    Advanced LIGO detected a significant gravitational wave signal (GW170104) originating from the coalescence of two black holes during the second observation run on January 4th, 2017. An all-sky high-energy neutrino follow-up search has been made using data from the Antares neutrino telescope, including both upgoing and downgoing events in two separate analyses. No neutrino candidates were found within ±500 s around the GW event time nor any time clustering of events over an extended time window of ±3 months. The non-detection is used to constrain isotropic-equivalent high-energy neutrino emission from GW170104 to less than ∝ 1.2 x 10 55 erg for a E -2 spectrum. This constraint is valid in the energy range corresponding to the 5-95% quantiles of the neutrino flux [3.2 TeV; 3.6 PeV], if the GW emitter was below the Antares horizon at the alert time. (orig.)

  18. All-sky search for high-energy neutrinos from gravitational wave event GW170104 with the Antares neutrino telescope

    Energy Technology Data Exchange (ETDEWEB)

    Albert, A.; Drouhin, D.; Racca, C. [Universite de Haute Alsace - Institut Universitaire de Technologie de Colmar, GRPHE, Colmar (France); Andre, M. [Technical University of Catalonia, Laboratory of Applied Bioacoustics, Vilanova i la Geltru, Barcelona (Spain); Anghinolfi, M. [INFN-Sezione di Genova, Genoa (Italy); Anton, G.; Eberl, T.; Graf, K.; Hallmann, S.; Hoessl, J.; Hofestaedt, J.; James, C.W.; Kalekin, O.; Katz, U.; Kiessling, D.; Lahmann, R.; Sieger, C. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen Centre for Astroparticle Physics, Erlangen (Germany); Ardid, M.; Felis, I.; Martinez-Mora, J.A.; Saldana, M. [Universitat Politecnica de Valencia, Institut d' Investigacio per a la Gestio Integrada de les Zones Costaneres (IGIC), Gandia (Spain); Aubert, J.J.; Bertin, V.; Brunner, J.; Busto, J.; Carr, J.; Costantini, H.; Coyle, P.; Dornic, D.; Enzenhoefer, A.; Quinn, L.; Salvadori, I.; Turpin, D. [Aix Marseille Univ., CNRS/IN2P3, CPPM, Marseille (France); Avgitas, T.; Baret, B.; Bourret, S.; Coelho, J.A.B.; Creusot, A.; Gregoire, T.; Gracia Ruiz, R.; Lachaud, C. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (France); Barrios-Marti, J.; Hernandez-Rey, J.J.; Illuminati, G.; Lotze, M.; Toennis, C.; Zornoza, J.D.; Zuniga, J. [IFIC-Instituto de Fisica Corpuscular (CSIC-Universitat de Valencia), Paterna, Valencia (Spain); Basa, S.; Marcelin, M.; Nezri, E. [Pole de l' Etoile Site de Chateau-Gombert, LAM-Laboratoire d' Astrophysique de Marseille (France); Belhorma, B. [National Center for Energy Sciences and Nuclear Techniques, Rabat (Morocco); Biagi, S.; Coniglione, R.; Distefano, C.; Piattelli, P.; Riccobene, G.; Sapienza, P.; Trovato, A. [INFN-Laboratori Nazionali del Sud (LNS), Catania (Italy); Bormuth, R.; Jong, M. de; Samtleben, D.F.E. [Nikhef, Amsterdam (Netherlands); Universiteit Leiden, Huygens-Kamerlingh Onnes Laboratorium, Leiden (Netherlands); Bouwhuis, M.C.; Heijboer, A.J.; Jongen, M.; Michael, T. [Nikhef, Amsterdam (Netherlands); Branzas, H.; Caramete, L.; Pavalas, G.E.; Popa, V. [Institute for Space Science, Bucharest (Romania); Bruijn, R.; Melis, K. [Nikhef, Amsterdam (Netherlands); Universiteit van Amsterdam, Instituut voor Hoge-Energie Fysica, Amsterdam (Netherlands); Capone, A.; Di Palma, I.; Perrina, C.; Vizzoca, A. [INFN-Sezione di Roma, Rome (Italy); Dipartimento di Fisica dell' Universita La Sapienza, Rome (Italy); Celli, S. [INFN-Sezione di Roma, Rome (Italy); Dipartimento di Fisica dell' Universita La Sapienza, Rome (Italy); Gran Sasso Science Institute, L' Aquila (Italy); Cherkaoui El Moursli, R.; El Khayati, N.; Ettahiri, A.; Fassi, F.; Tayalati, Y. [University Mohammed V, Faculty of Sciences, Rabat (Morocco); Chiarusi, T. [INFN-Sezione di Bologna, Bologna (Italy); Circella, M.; Sanchez-Losa, A. [INFN-Sezione di Bari, Bari (Italy); Coleiro, A. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (France); IFIC-Instituto de Fisica Corpuscular (CSIC-Universitat de Valencia), Paterna, Valencia (Spain); Diaz, A.F. [University of Granada, Department of Computer Architecture and Technology/CITIC, Granada (Spain); Deschamps, A.; Hello, Y. [Geoazur, UCA, CNRS, IRD, Observatoire de la Cote d' Azur, Sophia Antipolis (France); De Bonis, G. [Dipartimento di Fisica dell' Universita La Sapienza, Rome (Italy); Domi, A.; Hugon, C.; Sanguineti, M.; Taiuti, M. [INFN-Sezione di Genova, Genoa (Italy); Dipartimento di Fisica dell' Universita, Genoa (Italy); Donzaud, C. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (France); Universite Paris-Sud, Orsay (France); El Bojaddaini, I.; Moussa, A. [University Mohammed I, Laboratory of Physics of Matter and Radiations, Oujda (Morocco); Elsaesser, D.; Kadler, M.; Kreter, M. [Institut fuer Theoretische Physik und Astrophysik, Universitaet Wuerzburg, Wuerzburg (Germany); Fusco, L.A.; Margiotta, A.; Pellegrino, C.; Spurio, M.; Versari, F. [INFN-Sezione di Bologna, Bologna (Italy); Dipartimento di Fisica e Astronomia dell' Universita, Bologna (Italy); Gay, P. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (France); Clermont Universite, Universite Blaise Pascal, Laboratoire de Physique Corpusculaire, CNRS/IN2P3, Clermont-Ferrand (France); Giordano, V. [INFN-Sezione di Catania, Catania (Italy); Glotin, H. [LSIS, Aix Marseille Universite CNRS ENSAM LSIS UMR 7296, Marseille (France); Universite de Toulon CNRS LSIS UMR 7296, La Garde (FR); Institut Universitaire de France, Paris (FR); Haren, H. van [Utrecht University, Royal Netherlands Institute for Sea Research (NIOZ), ' t Horntje (Texel) (NL); Kouchner, A.; Van Elewyck, V. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (FR); Institut Universitaire de France, Paris (FR); Kreykenbohm, I.; Wilms, J. [Universitaet Erlangen-Nuernberg, Dr. Remeis-Sternwarte and ECAP, Bamberg (DE); Kulikovskiy, V. [Aix Marseille Univ., CNRS/IN2P3, CPPM, Marseille (FR); Moscow State University, Skobeltsyn Institute of Nuclear Physics, Moscow (RU); Lefevre, D. [Aix-Marseille University, Mediterranean Institute of Oceanography (MIO), Marseille (FR); Universite du Sud Toulon-Var, CNRS-INSU/IRD UM 110, La Garde (FR); Leonora, E. [INFN-Sezione di Catania, Catania (IT); Dipartimento di Fisica e Astronomia dell' Universita, Catania (IT); Loucatos, S.; Vallage, B. [Univ Paris Diderot, CNRS/IN2P3, CEA/Irfu, Obs de Paris, Sorbonne Paris Cite, APC, Paris (FR); Direction des Sciences de la Matiere-Institut de Recherche sur les Lois Fondamentales de l' Univers-Service de Physique des Particules, CEA Saclay, Gif-sur-Yvette (FR); Marinelli, A. [INFN-Sezione di Pisa, Pisa (IT); Dipartimento di Fisica dell' Universita, Pisa (IT); Mele, R.; Vivolo, D. [INFN-Sezione di Napoli, Naples (IT); Dipartimento di Fisica dell' Universita Federico II di Napoli, Naples (IT); Migliozzi, P. [INFN-Sezione di Napoli, Naples (IT); Navas, S. [University of Granada, Dept. de Fisica Teorica y del Cosmos y C.A.F.P.E., Granada (ES); Organokov, M.; Pradier, T. [Universite de Strasbourg, CNRS, Strasbourg (FR); Schuessler, F.; Stolarczyk, T. [Direction des Sciences de la Matiere-Institut de Recherche sur les Lois Fondamentales de l' Univers-Service de Physique des Particules, CEA Saclay, Gif-sur-Yvette (FR); Collaboration: The ANTARES Collaboration

    2017-12-15

    Advanced LIGO detected a significant gravitational wave signal (GW170104) originating from the coalescence of two black holes during the second observation run on January 4th, 2017. An all-sky high-energy neutrino follow-up search has been made using data from the Antares neutrino telescope, including both upgoing and downgoing events in two separate analyses. No neutrino candidates were found within ±500 s around the GW event time nor any time clustering of events over an extended time window of ±3 months. The non-detection is used to constrain isotropic-equivalent high-energy neutrino emission from GW170104 to less than ∝ 1.2 x 10{sup 55} erg for a E{sup -2} spectrum. This constraint is valid in the energy range corresponding to the 5-95% quantiles of the neutrino flux [3.2 TeV; 3.6 PeV], if the GW emitter was below the Antares horizon at the alert time. (orig.)

  19. The influence of normal and high ultimate muscle pH on the microbiology and colour stability of previously frozen black wildebeest (Connochaetes gnou) meat.

    Science.gov (United States)

    Shange, Nompumelelo; Makasi, Thandeka N; Gouws, Pieter A; Hoffman, Louwrens C

    2018-01-01

    Changes in pH, colour and microbiological counts were investigated in previously frozen Biceps femoris (BF) muscles from black wildebeest. Samples were stored under vacuum at refrigerated conditions (4.2±0.8°C) for 12days. Seven BF muscles had a high pH (DFD) (pH≥6) and five had a normal pH (pHmeat decreased. Browning under anaerobic storage conditions was seen, more for normal meat than DFD meat. Initial total viable counts, lactic acid bacteria and coliform counts from samples with normal pH, were significantly higher than counts from the DFD samples. However, overtime DFD meat showed a faster increase for all microorganisms tested compared to normal pH meat. Overall, this study revealed that DFD meat can have a shorter shelf-life than normal pH meat stored at 4.2±0.8°C. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. High Quality Education and Learning for All through Open Education

    NARCIS (Netherlands)

    Stracke, Christian M.

    2016-01-01

    Keynote at the International Lensky Education Forum 2016, Yakutsk, Republic of Sakha, Russian Federation, by Stracke, C. M. (2016, 16 August): "High Quality Education and Learning for All through Open Education"

  1. High Rates of All-cause and Gastroenteritis-related Hospitalization Morbidity and Mortality among HIV-exposed Indian Infants

    Directory of Open Access Journals (Sweden)

    Tripathy Srikanth

    2011-07-01

    Full Text Available Abstract Background HIV-infected and HIV-exposed, uninfected infants experience a high burden of infectious morbidity and mortality. Hospitalization is an important metric for morbidity and is associated with high mortality, yet, little is known about rates and causes of hospitalization among these infants in the first 12 months of life. Methods Using data from a prevention of mother-to-child transmission (PMTCT trial (India SWEN, where HIV-exposed breastfed infants were given extended nevirapine, we measured 12-month infant all-cause and cause-specific hospitalization rates and hospitalization risk factors. Results Among 737 HIV-exposed Indian infants, 93 (13% were HIV-infected, 15 (16% were on HAART, and 260 (35% were hospitalized 381 times by 12 months of life. Fifty-six percent of the hospitalizations were attributed to infections; gastroenteritis was most common accounting for 31% of infectious hospitalizations. Gastrointestinal-related hospitalizations steadily increased over time, peaking around 9 months. The 12-month all-cause hospitalization, gastroenteritis-related hospitalization, and in-hospital mortality rates were 906/1000 PY, 229/1000 PY, and 35/1000 PY respectively among HIV-infected infants and 497/1000 PY, 107/1000 PY, and 3/1000 PY respectively among HIV-exposed, uninfected infants. Advanced maternal age, infant HIV infection, gestational age, and male sex were associated with higher all-cause hospitalization risk while shorter duration of breastfeeding and abrupt weaning were associated with gastroenteritis-related hospitalization. Conclusions HIV-exposed Indian infants experience high rates of all-cause and infectious hospitalization (particularly gastroenteritis and in-hospital mortality. HIV-infected infants are nearly 2-fold more likely to experience hospitalization and 10-fold more likely to die compared to HIV-exposed, uninfected infants. The combination of scaling up HIV PMTCT programs and implementing proven health

  2. High Reversibility of “Soft” Electrode Materials in All-Solid-State Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Sakuda, Atsushi, E-mail: a.sakuda@aist.go.jp; Takeuchi, Tomonari, E-mail: a.sakuda@aist.go.jp; Shikano, Masahiro; Sakaebe, Hikari; Kobayashi, Hironori [Department of Energy and Environment, Research Institute for Electrochemical Energy, National Institute of Advanced Industrial Science and Technology (AIST), Ikeda (Japan)

    2016-05-10

    All-solid-state batteries using inorganic solid electrolytes (SEs) are considered to be ideal batteries for electric vehicles and plug-in hybrid electric vehicles because they are potentially safer than conventional lithium-ion batteries (LIBs). In addition, all-solid-state batteries are expected to have long battery life owing to the inhibition of chemical side reactions because only lithium ions move through the typically used inorganic SEs. The development of high-energy density (more than 300 Wh kg{sup −1}) secondary batteries has been eagerly anticipated for years. The application of high-capacity electrode active materials is essential for fabricating such batteries. Recently, we proposed metal polysulfides as new electrode materials. These materials show higher conductivity and density than sulfur, which is advantageous for fabricating batteries with relatively higher energy density. Lithium niobium sulfides, such as Li{sub 3}NbS{sub 4}, have relatively high density, conductivity, and rate capability among metal polysulfide materials, and batteries with these materials have capacities high enough to potentially exceed the gravimetric-energy density of conventional LIBs. Favorable solid–solid contact between the electrode and electrolyte particles is a key factor for fabricating high performance all-solid-state batteries. Conventional oxide-based positive electrode materials tend to give rise to cracks during fabrication and/or charge–discharge processes. Here, we report all-solid-state cells using lithium niobium sulfide as a positive electrode material, where favorable solid–solid contact was established by using lithium sulfide electrode materials because of their high processability. Cracks were barely observed in the electrode particles in the all-solid-state cells before or after charging and discharging with a high capacity of approximately 400 mAh g{sup −1} suggesting that the lithium niobium sulfide electrode charged and discharged without

  3. High Reversibility of “Soft” Electrode Materials in All-Solid-State Batteries

    International Nuclear Information System (INIS)

    Sakuda, Atsushi; Takeuchi, Tomonari; Shikano, Masahiro; Sakaebe, Hikari; Kobayashi, Hironori

    2016-01-01

    All-solid-state batteries using inorganic solid electrolytes (SEs) are considered to be ideal batteries for electric vehicles and plug-in hybrid electric vehicles because they are potentially safer than conventional lithium-ion batteries (LIBs). In addition, all-solid-state batteries are expected to have long battery life owing to the inhibition of chemical side reactions because only lithium ions move through the typically used inorganic SEs. The development of high-energy density (more than 300 Wh kg −1 ) secondary batteries has been eagerly anticipated for years. The application of high-capacity electrode active materials is essential for fabricating such batteries. Recently, we proposed metal polysulfides as new electrode materials. These materials show higher conductivity and density than sulfur, which is advantageous for fabricating batteries with relatively higher energy density. Lithium niobium sulfides, such as Li 3 NbS 4 , have relatively high density, conductivity, and rate capability among metal polysulfide materials, and batteries with these materials have capacities high enough to potentially exceed the gravimetric-energy density of conventional LIBs. Favorable solid–solid contact between the electrode and electrolyte particles is a key factor for fabricating high performance all-solid-state batteries. Conventional oxide-based positive electrode materials tend to give rise to cracks during fabrication and/or charge–discharge processes. Here, we report all-solid-state cells using lithium niobium sulfide as a positive electrode material, where favorable solid–solid contact was established by using lithium sulfide electrode materials because of their high processability. Cracks were barely observed in the electrode particles in the all-solid-state cells before or after charging and discharging with a high capacity of approximately 400 mAh g −1 suggesting that the lithium niobium sulfide electrode charged and discharged without experiencing

  4. Time evolution of the spectral break in the high-energy extra component of GRB 090926A

    Science.gov (United States)

    Yassine, M.; Piron, F.; Mochkovitch, R.; Daigne, F.

    2017-10-01

    Aims: The prompt light curve of the long GRB 090926A reveals a short pulse 10 s after the beginning of the burst emission, which has been observed by the Fermi observatory from the keV to the GeV energy domain. During this bright spike, the high-energy emission from GRB 090926A underwent a sudden hardening above 10 MeV in the form of an additional power-law component exhibiting a spectral attenuation at a few hundreds of MeV. This high-energy break has been previously interpreted in terms of gamma-ray opacity to pair creation and has been used to estimate the bulk Lorentz factor of the outflow. In this article, we report on a new time-resolved analysis of the GRB 090926A broadband spectrum during its prompt phase and on its interpretation in the framework of prompt emission models. Methods: We characterized the emission from GRB 090926A at the highest energies with Pass 8 data from the Fermi Large Area Telescope (LAT), which offer a greater sensitivity than any data set used in previous studies of this burst, particularly in the 30-100 MeV energy band. Then, we combined the LAT data with the Fermi Gamma-ray Burst Monitor (GBM) in joint spectral fits to characterize the time evolution of the broadband spectrum from keV to GeV energies. We paid careful attention to the systematic effects that arise from the uncertainties on the LAT response. Finally, we performed a temporal analysis of the light curves and we computed the variability timescales from keV to GeV energies during and after the bright spike. Results: Our analysis confirms and better constrains the spectral break, which has been previously reported during the bright spike. Furthermore, it reveals that the spectral attenuation persists at later times with an increase of the break characteristic energy up to the GeV domain until the end of the prompt phase. We discuss these results in terms of keV-MeV synchroton radiation of electrons accelerated during the dissipation of the jet energy and inverse Compton

  5. Alignment of time-resolved data from high throughput experiments.

    Science.gov (United States)

    Abidi, Nada; Franke, Raimo; Findeisen, Peter; Klawonn, Frank

    2016-12-01

    To better understand the dynamics of the underlying processes in cells, it is necessary to take measurements over a time course. Modern high-throughput technologies are often used for this purpose to measure the behavior of cell products like metabolites, peptides, proteins, [Formula: see text]RNA or mRNA at different points in time. Compared to classical time series, the number of time points is usually very limited and the measurements are taken at irregular time intervals. The main reasons for this are the costs of the experiments and the fact that the dynamic behavior usually shows a strong reaction and fast changes shortly after a stimulus and then slowly converges to a certain stable state. Another reason might simply be missing values. It is common to repeat the experiments and to have replicates in order to carry out a more reliable analysis. The ideal assumptions that the initial stimulus really started exactly at the same time for all replicates and that the replicates are perfectly synchronized are seldom satisfied. Therefore, there is a need to first adjust or align the time-resolved data before further analysis is carried out. Dynamic time warping (DTW) is considered as one of the common alignment techniques for time series data with equidistant time points. In this paper, we modified the DTW algorithm so that it can align sequences with measurements at different, non-equidistant time points with large gaps in between. This type of data is usually known as time-resolved data characterized by irregular time intervals between measurements as well as non-identical time points for different replicates. This new algorithm can be easily used to align time-resolved data from high-throughput experiments and to come across existing problems such as time scarcity and existing noise in the measurements. We propose a modified method of DTW to adapt requirements imposed by time-resolved data by use of monotone cubic interpolation splines. Our presented approach

  6. High-speed optical signal processing using time lenses

    DEFF Research Database (Denmark)

    Galili, Michael; Hu, Hao; Guan, Pengyu

    2015-01-01

    This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle.......This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle....

  7. A study about the interest and previous contact of high school students with Astronomy

    Science.gov (United States)

    Carvalho, C. L.; Zanitti, M. H. R.; Felicidade, B. L.; Gomes, A. D. T.; Dias, E. W.; Coelho, F. O.

    2016-04-01

    The currently problems in Astronomy teaching in Brazilian Basic Education contrast with the space, and the popularity that astronomical themes have in various media in the country. In this work, we present the results of a study about the interest, and previous contact of high school students from a public school in the city of "São João del-Rei"/MG with topics related to Astronomy. The study and the pedagogical intervention were carried out by students of the PIBID/CAPES/UFSJ. The intervention was performed through an oral exposition with the students' participation, followed by the use of the Stellarium program. The results suggest the majority of students surveyed are interested in Astronomy, and have had some contact with the area. However, some inconsistencies in their responses were identified and examined. The implications for research and for Astronomy Education are discussed. We also make some considerations about relationship between the lack of specific knowledge and the misinformation as one possible reason for the little interest of students in various areas of Science.

  8. Total knee replacement for tricompartmental arthritis in a patient with a below-knee amputation after a previous closing wedge high tibial osteotomy

    Directory of Open Access Journals (Sweden)

    Mark A. Fleming, MBBCH, FC orth(SA, MMED

    2016-06-01

    Full Text Available This is a report of a 64-year-old man who had undergone a high tibial osteotomy (HTO 17 years ago of his right knee for medial compartment osteoarthritis; 5 days later, he received a below-knee amputation owing to a missed popliteal artery injury at the time of the HTO. We elected to perform a total knee replacement (TKR for progressive arthritis of the ipsilateral knee 17 years after the transtibial amputation. Although there is a plethora of literature regarding TKR in the contralateral knee of amputees, there is a paucity of data of TKR in the ipsilateral knee. Using medical search engines including Google Scholar and PubMed, we were only able to identify 4 case reports of TKR in the ipsilateral knee of below-knee amputees. This is the first description in the English literature that has the following rare pathology list: tricompartmental arthritis with a previous closing wedge HTO with a resultant truncated valgus tibia and short transtibial amputation.

  9. Effects of high CO2 seawater on the copepod (Acartia tsuensis) through all life stages and subsequent generations

    International Nuclear Information System (INIS)

    Kurihara, Haruko; Ishimatsu, Atsushi

    2008-01-01

    We studied the effects of exposure to seawater equilibrated with CO 2 -enriched air (CO 2 2380 ppm) from eggs to maturity and over two subsequent generations on the copepod Acartia tsuensis. Compared to the control (CO 2 380 ppm), high CO 2 exposure through all life stages of the 1st generation copepods did not significantly affect survival, body size or developmental speed. Egg production and hatching rates were also not significantly different between the initial generation of females exposed to high CO 2 and the 1st and 2nd generation females developed from eggs to maturity in high CO 2 . Thus, the copepods appear more tolerant to increased CO 2 than other marine organisms previously investigated for CO 2 tolerance (i.e., sea urchins and bivalves). However, the crucial importance of copepods in marine ecosystems requires thorough evaluation of the overall impacts of marine environmental changes predicted to occur with increased CO 2 concentrations, i.e., increased temperature, enhanced UV irradiation, and changes in the community structure and nutritional value of phytoplankton

  10. Revision and simplification of the boarding previous minimum of the lumbar column

    International Nuclear Information System (INIS)

    Lazannec, JY; Del Vecchio, R; Ramare, S; Saillant, G

    2001-01-01

    This paper describes the boarding retroperineal previous minimum, which provides access at any level discal and vertebral between T12 and S1. It is carried out a technique of dissection retroperineal that facilitates the renal and duodenum-pancreatic mobilization to consent to the face previous left of the whole lumbar column and of the thoracic-lumbar union. They were carried out careful anatomical dissections in fresh cadavers and preserved to determine the topography and the anatomical relationships of interest and this way to develop a sure boarding and easily reproducible. Special attention has been paid to the description of the lumbar veins and the anastomosis between the vein renal left and the hemiacigos system for the exhibition of the expensive left anterolateral of T12 and L1. A series of 94 patients is reported with lesions caused by traumas or degenerative processes. For all the lumbar levels, even in-patient with antecedents of surgery intraperitoneal, the boarding minimum retroperitoneal, was safe for the kidneys, ureters, spleen, hypo gastric plexus and duodenum-pancreatic union. Better cosmetic results are reported, decrease of the time surgical, scarce bled intraoperatory and easiness for the decortications and placement of implants. The previous boarding minimum retro peritoneal of the column developed starting from the boarding classic retroperineals, offers significant advantages on the endoscopic techniques, which require sophisticated machinery and they are technically plaintiffs. The exhibition of all the lumbar levels, as well as the reduction maneuvers and placement of implants, they can be carried out with easiness without causing muscular damage

  11. Prospects for high-precision pulsar timing with the new Effelsberg PSRIX backend

    Science.gov (United States)

    Lazarus, P.; Karuppusamy, R.; Graikou, E.; Caballero, R. N.; Champion, D. J.; Lee, K. J.; Verbiest, J. P. W.; Kramer, M.

    2016-05-01

    The PSRIX backend is the primary pulsar timing instrument of the Effelsberg 100 m radio telescope since early 2011. This new ROACH-based system enables bandwidths up to 500 MHz to be recorded, significantly more than what was possible with its predecessor, the Effelsberg-Berkeley Pulsar Processor (EBPP). We review the first four years of PSRIX timing data for 33 pulsars collected as part of the monthly European Pulsar Timing Array (EPTA) observations. We describe the automated data analysis pipeline, COASTGUARD, that we developed to reduce these observations. We also introduce TOASTER, the EPTA timing data base, used to store timing results, processing information and observation metadata. Using these new tools, we measure the phase-averaged flux densities at 1.4 GHz of all 33 pulsars. For seven of these pulsars, our flux density measurements are the first values ever reported. For the other 26 pulsars, we compare our flux density measurements with previously published values. By comparing PSRIX data with EBPP data, we find an improvement of ˜2-5 times in signal-to-noise ratio, which translates to an increase of ˜2-5 times in pulse time-of-arrival (TOA) precision. We show that such an improvement in TOA precision will improve the sensitivity to the stochastic gravitational wave background. Finally, we showcase the flexibility of the new PSRIX backend by observing several millisecond-period pulsars (MSPs) at 5 and 9 GHz. Motivated by our detections, we discuss the potential for complementing existing pulsar timing array data sets with MSP monitoring campaigns at these higher frequencies.

  12. Implant breast reconstruction after salvage mastectomy in previously irradiated patients.

    Science.gov (United States)

    Persichetti, Paolo; Cagli, Barbara; Simone, Pierfranco; Cogliandro, Annalisa; Fortunato, Lucio; Altomare, Vittorio; Trodella, Lucio

    2009-04-01

    The most common surgical approach in case of local tumor recurrence after quadrantectomy and radiotherapy is salvage mastectomy. Breast reconstruction is the subsequent phase of the treatment and the plastic surgeon has to operate on previously irradiated and manipulated tissues. The medical literature highlights that breast reconstruction with tissue expanders is not a pursuable option, considering previous radiotherapy a contraindication. The purpose of this retrospective study is to evaluate the influence of previous radiotherapy on 2-stage breast reconstruction (tissue expander/implant). Only patients with analogous timing of radiation therapy and the same demolitive and reconstructive procedures were recruited. The results of this study prove that, after salvage mastectomy in previously irradiated patients, implant reconstruction is still possible. Further comparative studies are, of course, advisable to draw any conclusion on the possibility to perform implant reconstruction in previously irradiated patients.

  13. Indiana pouch continent urinary reservoir in patients with previous pelvic irradiation

    International Nuclear Information System (INIS)

    Mannel, R.S.; Braly, P.S.; Buller, R.E.

    1990-01-01

    Little information exists on the use of continent urinary reservoirs in patients with previous pelvic irradiation. We report the use of the Indiana pouch urinary reservoir in ten women with a history of pelvic irradiation for cervical cancer, of whom eight underwent a total pelvic exenteration for recurrent pelvic tumor and two had diversion for radiation-induced vesicovaginal fistula. All ten women achieved daytime continence, with a median time between catheterizations of 4.5 hours and a median pouch capacity of 500 mL. There was no evidence of leakage from the reservoir or significant ureteral reflux or obstruction on postoperative radiographic evaluation. No patient has required reoperation or had significant postoperative complications with the technique described

  14. 14 CFR 121.406 - Credit for previous CRM/DRM training.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Credit for previous CRM/DRM training. 121... previous CRM/DRM training. (a) For flightcrew members, the Administrator may credit CRM training received before March 19, 1998 toward all or part of the initial ground CRM training required by § 121.419. (b...

  15. 3D-Printed, All-in-One Evaporator for High-Efficiency Solar Steam Generation under 1 Sun Illumination.

    Science.gov (United States)

    Li, Yiju; Gao, Tingting; Yang, Zhi; Chen, Chaoji; Luo, Wei; Song, Jianwei; Hitz, Emily; Jia, Chao; Zhou, Yubing; Liu, Boyang; Yang, Bao; Hu, Liangbing

    2017-07-01

    Using solar energy to generate steam is a clean and sustainable approach to addressing the issue of water shortage. The current challenge for solar steam generation is to develop easy-to-manufacture and scalable methods which can convert solar irradiation into exploitable thermal energy with high efficiency. Although various material and structure designs have been reported, high efficiency in solar steam generation usually can be achieved only at concentrated solar illumination. For the first time, 3D printing to construct an all-in-one evaporator with a concave structure for high-efficiency solar steam generation under 1 sun illumination is used. The solar-steam-generation device has a high porosity (97.3%) and efficient broadband solar absorption (>97%). The 3D-printed porous evaporator with intrinsic low thermal conductivity enables heat localization and effectively alleviates thermal dissipation to the bulk water. As a result, the 3D-printed evaporator has a high solar steam efficiency of 85.6% under 1 sun illumination (1 kW m -2 ), which is among the best compared with other reported evaporators. The all-in-one structure design using the advanced 3D printing fabrication technique offers a new approach to solar energy harvesting for high-efficiency steam generation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Nonparametric estimation in an "illness-death" model when all transition times are interval censored

    DEFF Research Database (Denmark)

    Frydman, Halina; Gerds, Thomas; Grøn, Randi

    2013-01-01

    We develop nonparametric maximum likelihood estimation for the parameters of an irreversible Markov chain on states {0,1,2} from the observations with interval censored times of 0 → 1, 0 → 2 and 1 → 2 transitions. The distinguishing aspect of the data is that, in addition to all transition times ...

  17. And a Good Time Was Had by All!

    Directory of Open Access Journals (Sweden)

    Norman L Jones

    2000-01-01

    Full Text Available As I write this, the American Thoracic Society 2000 meeting held in Toronto has been over for a week. From every point of view it seems to have been a great success. While having the drawbacks of very large meetings, with some tiresome separation between different sessions, one could not complain about the depth of coverage, with over 6000 poster and slide presentations. I was particularly impressed with the number of senior researchers who took part and demonstrated amply that they were not merely names from the past but had much to offer research fellows, especially on a one-to-one basis. One could find standing in front of a poster -- Sol Permutt, Bob Hyatt, John West, Ann Woolcock, Neil Pride and many others who gave freely of their time, experience and wisdom. There can be no better meeting showcasing international respiratory research from all over the globe. The Canadian Thoracic Society (CTS was prominent in the organization and presentation, and deserves to feel proud of the meeting's success; the Society's annual dinner was well and enthusiastically attended. At the dinner, Dr Clarence Guenter gave the Christie Lecture, which will appear in the Journal before the end of the year.

  18. High throughput web inspection system using time-stretch real-time imaging

    Science.gov (United States)

    Kim, Chanju

    Photonic time-stretch is a novel technology that enables capturing of fast, rare and non-repetitive events. Therefore, it operates in real-time with ability to record over long period of time while having fine temporal resolution. The powerful property of photonic time-stretch has already been employed in various fields of application such as analog-to-digital conversion, spectroscopy, laser scanner and microscopy. Further expanding the scope, we fully exploit the time-stretch technology to demonstrate a high throughput web inspection system. Web inspection, namely surface inspection is a nondestructive evaluation method which is crucial for semiconductor wafer and thin film production. We successfully report a dark-field web inspection system with line scan speed of 90.9 MHz which is up to 1000 times faster than conventional inspection instruments. The manufacturing of high quality semiconductor wafer and thin film may directly benefit from this technology as it can easily locate defects with area of less than 10 microm x 10 microm where it allows maximum web flow speed of 1.8 km/s. The thesis provides an overview of our web inspection technique, followed by description of the photonic time-stretch technique which is the keystone in our system. A detailed explanation of each component is covered to provide quantitative understanding of the system. Finally, imaging results from a hard-disk sample and flexible films are presented along with performance analysis of the system. This project was the first application of time-stretch to industrial inspection, and was conducted under financial support and with close involvement by Hitachi, Ltd.

  19. Not all stories of professional identity formation are equal: An analysis of formation narratives of highly humanistic physicians.

    Science.gov (United States)

    Branch, William T; Frankel, Richard

    2016-08-01

    We sought to identify and define "highly humanistic" formation narratives, and understand how these events described, together with a reflective learning process, the professional development of physicians in a longitudinal faculty development program. Qualitative analysis of twenty highly humanistic appreciative inquiry narratives selected from a total of 124 written by faculty members at the beginning and end of an eighteen month program at eight medical schools. [9,10] We employed the immersion/crystallization method of Borkan [20] to capture the rich meanings and emotional depth of the twenty narratives. Highly humanistic formation narratives described emotionally charged events in which the faculty writers provided humanistic care that went beyond what they had previously thought themselves capable of; benefited the patient, family or faculty member to a major extent; and reaffirmed or strengthened their professional values. Highly humanistic formation narratives were clustered at the end of our eighteen month curriculum. Participation in faculty development for humanism may have increased the numbers of highly humanistic events by sensitizing and motivating faculty members to meet their patients' emotional needs. Our paper describes a process whereby faculty members may achieve growth in their capacities to meet patients' needs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. High Performance All-solid Supercapacitors Based on the Network of Ultralong Manganese dioxide/Polyaniline Coaxial Nanowires.

    Science.gov (United States)

    Zhou, Junli; Yu, Lin; Liu, Wei; Zhang, Xiaodan; Mu, Wei; Du, Xu; Zhang, Zhe; Deng, Yulin

    2015-12-08

    In recent years, thin, lightweight and flexible solid supercapacitors are of considerable interest as energy storage devices. Here we demonstrated all-solid supercapacitors (SSCs) with high electrochemical properties, low self-discharge characteristics based on manganese dioxide/polyaniline (MNW/PANI) coaxial nanowire networks. The synergistic effect of MnO2/PANI plus the unique coaxial nanostructure of the ultralong nanowires with a highly interconnected network effectively enhance the conductivity and capacitive performance of the SSCs device. The MNW/PANI composite with 62.5% MnO2 exhibits an outstanding areal specific capacitance reaching 346 mF/cm(2) at 5 mV s(-1) which is significant higher than most previously reported solid supercapacitors (15.3 mF/cm(2)-109 mF/cm(2)) and is close to the that of the best graphene films solid state supercapacitors (372 mF/cm(2)). In contrast, only 190 mF/cm(2) of areal specific capacitance was obtained for the pure MnO2 NW network. The supercapacitors also exhibited low leakage current as small as 20.1 μA, which demonstrated that the MNW/PANI SSCs have great potential for practical applications.

  1. High Performance All-solid Supercapacitors Based on the Network of Ultralong Manganese dioxide/Polyaniline Coaxial Nanowires

    Science.gov (United States)

    Zhou, Junli; Yu, Lin; Liu, Wei; Zhang, Xiaodan; Mu, Wei; Du, Xu; Zhang, Zhe; Deng, Yulin

    2015-12-01

    In recent years, thin, lightweight and flexible solid supercapacitors are of considerable interest as energy storage devices. Here we demonstrated all-solid supercapacitors (SSCs) with high electrochemical properties, low self-discharge characteristics based on manganese dioxide/polyaniline (MNW/PANI) coaxial nanowire networks. The synergistic effect of MnO2/PANI plus the unique coaxial nanostructure of the ultralong nanowires with a highly interconnected network effectively enhance the conductivity and capacitive performance of the SSCs device. The MNW/PANI composite with 62.5% MnO2 exhibits an outstanding areal specific capacitance reaching 346 mF/cm2 at 5 mV s-1 which is significant higher than most previously reported solid supercapacitors (15.3 mF/cm2-109 mF/cm2) and is close to the that of the best graphene films solid state supercapacitors (372 mF/cm2). In contrast, only 190 mF/cm2 of areal specific capacitance was obtained for the pure MnO2 NW network. The supercapacitors also exhibited low leakage current as small as 20.1 μA, which demonstrated that the MNW/PANI SSCs have great potential for practical applications.

  2. All high T sub c edge junctions and SQUIDs

    Energy Technology Data Exchange (ETDEWEB)

    Laibowitz, R.B.; Koch, R.H.; Gupta, A.; Koren, G.; Gallagher, W.J.; Foglietti, V.; Oh, B.; Viggiano, J.M. (IBM Research Division, P.O. Box 218, Yorktown Heights, New York 10598 (US))

    1990-02-12

    We present the first observations of superconducting quantum interference in multilevel, all high {ital T}{sub {ital c}}, lithographically patterned edge junction structures. The current-voltage characteristics are nonhysteretic and have well-defined critical currents. The dynamic resistance is independent of current above the critical current. These devices show periodic sensitivity to magnetic fields and low levels of magnetic hysteresis up to temperatures around 60 K.

  3. Bacterial translational regulations: high diversity between all mRNAs and major role in gene expression

    Directory of Open Access Journals (Sweden)

    Picard Flora

    2012-10-01

    Full Text Available Abstract Background In bacteria, the weak correlations at the genome scale between mRNA and protein levels suggest that not all mRNAs are translated with the same efficiency. To experimentally explore mRNA translational level regulation at the systemic level, the detailed translational status (translatome of all mRNAs was measured in the model bacterium Lactococcus lactis in exponential phase growth. Results Results demonstrated that only part of the entire population of each mRNA species was engaged in translation. For transcripts involved in translation, the polysome size reached a maximum of 18 ribosomes. The fraction of mRNA engaged in translation (ribosome occupancy and ribosome density were not constant for all genes. This high degree of variability was analyzed by bioinformatics and statistical modeling in order to identify general rules of translational regulation. For most of the genes, the ribosome density was lower than the maximum value revealing major control of translation by initiation. Gene function was a major translational regulatory determinant. Both ribosome occupancy and ribosome density were particularly high for transcriptional regulators, demonstrating the positive role of translational regulation in the coordination of transcriptional networks. mRNA stability was a negative regulatory factor of ribosome occupancy and ribosome density, suggesting antagonistic regulation of translation and mRNA stability. Furthermore, ribosome occupancy was identified as a key component of intracellular protein levels underlining the importance of translational regulation. Conclusions We have determined, for the first time in a bacterium, the detailed translational status for all mRNAs present in the cell. We have demonstrated experimentally the high diversity of translational states allowing individual gene differentiation and the importance of translation-level regulation in the complex process linking gene expression to protein

  4. Positivity-preserving space-time CE/SE scheme for high speed flows

    KAUST Repository

    Shen, Hua

    2017-03-02

    We develop a space-time conservation element and solution element (CE/SE) scheme using a simple slope limiter to preserve the positivity of the density and pressure in computations of inviscid and viscous high-speed flows. In general, the limiter works with all existing CE/SE schemes. Here, we test the limiter on a central Courant number insensitive (CNI) CE/SE scheme implemented on hybrid unstructured meshes. Numerical examples show that the proposed limiter preserves the positivity of the density and pressure without disrupting the conservation law; it also improves robustness without losing accuracy in solving high-speed flows.

  5. Positivity-preserving space-time CE/SE scheme for high speed flows

    KAUST Repository

    Shen, Hua; Parsani, Matteo

    2017-01-01

    We develop a space-time conservation element and solution element (CE/SE) scheme using a simple slope limiter to preserve the positivity of the density and pressure in computations of inviscid and viscous high-speed flows. In general, the limiter works with all existing CE/SE schemes. Here, we test the limiter on a central Courant number insensitive (CNI) CE/SE scheme implemented on hybrid unstructured meshes. Numerical examples show that the proposed limiter preserves the positivity of the density and pressure without disrupting the conservation law; it also improves robustness without losing accuracy in solving high-speed flows.

  6. Homicide and domestic violence. Are there different psychological profiles mediated by previous exerted on the victim?

    Directory of Open Access Journals (Sweden)

    Montserrat Yepes

    2009-07-01

    Full Text Available A sample of 46 men was evaluated with the DAPP (Questionnaire of Domestic Aggressor Psychological Profile. All were inmates convicted for various degrees of violence against their wives in different prisons. The sample was divided into three groups: homicides without previous violence against their wives (H (n=11, homicides with previous violence (VH (n=9 and domestic batterers without previous homicide attempts against their partners (B (n=26. The aim of the study was to analyze the possible existence of three different kinds of profiles and more specifically if it’s possible to obtain an independent profile for domestic homicides with previous episodes of violence against their wives. The results neither confirm the hypothesis as whole nor for the violent homicides. However, differences between groups were obtained in the admission and description of the facts, in the risk of future violence, in some sociodemographical characteristics (i.e., level of education, social status, in the couple relationship, in the dissatisfaction concerning the unachieved ideal woman, in the use of extreme physical force during the aggression, the time of the first aggression, the use of verbal threats during the aggression, explanation of the events to the family and the period of time between the beginning of the romantic relationship and the manifestation of violence. The implications of the results for the theoretical frameworks proposed and future research are discussed.

  7. Not all hours are equal: could time be a social determinant of health?

    Science.gov (United States)

    Strazdins, Lyndall; Welsh, Jennifer; Korda, Rosemary; Broom, Dorothy; Paolucci, Francesco

    2016-01-01

    Time can be thought of as a resource that people need for good health. Healthy behaviour, accessing health services, working, resting and caring all require time. Like other resources, time is socially shaped, but its relevance to health and health inequality is yet to be established. Drawing from sociology and political economy, we set out the theoretical basis for two measures of time relevant to contemporary, market-based societies. We measure amount of time spent on care and work (paid and unpaid) and the intensity of time, which refers to rushing, effort and speed. Using data from wave 9 (N = 9177) of the Household, Income and Labour Dynamics of Australia Survey we found that time poverty (> 80 h per week on care and work) and often or always rushing are barriers to physical activity and rushing is associated with poorer self-rated and mental health. Exploring their social patterning, we find that time-poor people have higher incomes and more time control. In contrast, rushing is linked to being a woman, lone parenthood, disability, lack of control and work-family conflicts. We supply a methodology to support quantitative investigations of time, and our findings underline time's dimensionality, social distribution and potential to influence health. © 2015 The Authors. Sociology of Health & Illness published by John Wiley & Sons Ltd on behalf of Foundation for SHIL.

  8. High efficiency all-optical plasmonic diode based on a nonlinear side-coupled waveguide-cavity structure with broken symmetry

    Science.gov (United States)

    Liang, Hong-Qin; Liu, Bin; Hu, Jin-Feng; He, Xing-Dao

    2018-05-01

    An all-optical plasmonic diode, comprising a metal-insulator-metal waveguide coupled with a stub cavity, is proposed based on a nonlinear Fano structure. The key technique used is to break structural spatial symmetry by a simple reflector layer in the waveguide. The spatial asymmetry of the structure gives rise to the nonreciprocity of coupling efficiencies between the Fano cavity and waveguides on both sides of the reflector layer, leading to a nonreciprocal nonlinear response. Transmission properties and dynamic responses are numerically simulated and investigated by the nonlinear finite-difference time-domain method. In the proposed structure, high-efficiency nonreciprocal transmission can be achieved with a low power threshold and an ultrafast response time (subpicosecond level). A high maximum transmittance of 89.3% and an ultra-high transmission contrast ratio of 99.6% can also be obtained. The device can be flexibly adjusted for working wavebands by altering the stub cavity length.

  9. High 15-F2t-Isoprostane Levels in Patients with a Previous History of Nonmelanoma Skin Cancer: The Effects of Supplementary Antioxidant Therapy

    Directory of Open Access Journals (Sweden)

    Betânia de Jesus e Silva de Almendra Freitas

    2015-01-01

    Full Text Available Background. Phase I of this study was aimed at comparing the profiles of oxidative stress biomarkers in patients with history of nonmelanoma skin cancer (NMSC, previously treated with surgery, to the healthy subjects. Phase II aimed to evaluate the effects of supplementary antioxidant therapy on the levels of biomarkers in the case group. Materials and Methods. In Phase I, oxidative stress biomarkers were measured in blood samples obtained from 24 healthy subjects and 60 patients with history of NMSC previously treated with surgery. In Phase II, the 60 patients with history of NMSC were randomized into two subgroups, one receiving placebo (n=34 and the other (n=26 receiving vitamin C, vitamin E, and zinc supplementation for 8 weeks, followed by reevaluation of biomarkers. Results. In Phase I, patients with history of NMSC showed increased plasma concentrations of all biomarkers, but only 15-F2t-isoprostane was significantly higher than in the healthy subjects. Risk of NMSC increased by 4% for each additional 1 pg/mL increase in 15-F2t-isoprostane. In Phase II, supplementation did not significantly reduce levels of oxidative stress biomarkers. Conclusion. Patients with history of NMSC had significantly high 15-F2t-isoprostane plasma levels; supplementation did not result in significant reduction of oxidative stress biomarkers. This trial was registered with ClinicalTrials.gov (ID NCT02248584.

  10. Sudden unexpected death in children with a previously diagnosed cardiovascular disorder

    NARCIS (Netherlands)

    Polderman, Florens N.; Cohen, Joeri; Blom, Nico A.; Delhaas, Tammo; Helbing, Wim A.; Lam, Jan; Sobotka-Plojhar, Marta A.; Temmerman, Arno M.; Sreeram, Narayanswani

    2004-01-01

    BACKGROUND: It is known that children with previously diagnosed heart defects die suddenly. The causes of death are often unknown. OBJECTIVE: The aim of the study was to identify all infants and children within the Netherlands with previously diagnosed heart disease who had a sudden unexpected death

  11. Sudden unexpected death in children with a previously diagnosed cardiovascular disorder

    NARCIS (Netherlands)

    Polderman, F.N.; Cohen, Joeri; Blom, N.A.; Delhaas, T.; Helbing, W.A.; Lam, J.; Sobotka-Plojhar, M.A.; Temmerman, Arno M.; Sreeram, N.

    2004-01-01

    Background: It is known that children with previously diagnosed heart defects die suddenly. The causes of death are often unknown. Objective: The aim of the study was to identify all infants and children within the Netherlands with previously diagnosed heart disease who had a sudden unexpected death

  12. Outcome of trial of scar in patients with previous caesarean section

    International Nuclear Information System (INIS)

    Khan, B.; Bashir, R.; Khan, W.

    2016-01-01

    Medical evidence indicates that 60-80% of women can achieve vaginal delivery after a previous lower segment caesarean section. Proper selection of patients for trial of scar and vigilant monitoring during labour will achieve successful maternal and perinatal outcome. The objective of our study is to establish the fact that vaginal delivery after one caesarean section has a high success rate in patients with previous one caesarean section for non-recurrent cause. Methods: The study was conducted in Ayub Teaching Abbottabad, Gynae-B Unit. All labouring patients, during the study period of five years, with previous one caesarean section and between 37 weeks to 41 weeks of gestation for a non-recurrent cause were included in the study. Data was recorded on special proforma designed for the purpose. Patients who had previous classical caesarean section, more than one caesarean section, and previous caesarean section with severe wound infection, transverse lie and placenta previa in present pregnancy were excluded. Foetal macrosomia (wt>4 kg) and severe IUGR with compromised blood flow on Doppler in present pregnancy were also not considered suitable for the study. Patients who had any absolute contraindication for vaginal delivery were also excluded. Results: There were 12505 deliveries during the study period. Total vaginal deliveries were 8790 and total caesarean sections were 3715. Caesarean section rate was 29.7%. Out of these 8790 patients, 764 patients were given a trial of scar and 535 patients delivered successfully vaginally (70%). Women who presented with spontaneous onset of labour were more likely to deliver vaginally (74.8%) as compared to induction group (27.1%). Conclusion: Trial of vaginal birth after caesarean (VBAC) in selected cases has great importance in the present era of the rising rate of primary caesarean section. (author)

  13. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  14. The ATLAS High-Granularity Timing Detector

    CERN Document Server

    Sacerdoti, Sabrina; The ATLAS collaboration

    2018-01-01

    In the high luminosity phase of the LHC, scheduled to start in 2026, the instantaneous luminosity will be increased to up to $\\mathcal{L} = 7.5 × 10^{34} cm^{−2}s^{−1}$. As a consequence, the detectors will be faced with challenging conditions, in particular the increase of pile-up: an average of 200 interactions per bunch crossing are expected, corresponding to an average interaction density of 1.8 collisions/mm. The reconstruction performance will be severely degraded in the end-cap and forward region of the ATLAS detector, especially for jets and transverse missing energy. The addition of timing information in forward objects through the High-Granularity Timing Detector will help to recover the performance of these regions to levels similar to the ones expected in the central region of the detector. It will also provide a bunch-by-bunch luminosity measurement. This talk will be focused on the developments surrounding the LGAD sensors and front-end electronics, which are aimed to achieve a low time res...

  15. Assessment of the Relationship between Recurrent High-risk Pregnancy and Mothers’ Previous Experience of Having an Infant Admitted to a Neonatal Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Sedigheh Hantoosh Zadeh

    2015-01-01

    Full Text Available Background & aim:  High-risk pregnancies increase the risk of Intensive Care Unit (ICU and Neonatal Intensive Care Unit (NICU admission in mothers and their newborns. In this study, we aimed to identify the association between the recurrence of high-risk pregnancy and mothers’ previous experience of having an infant admitted to NICU. Methods:We performed a cohort, retrospective study to compare subsequent pregnancy outcomes among 232 control subjects and 200 female cases with a previous experience of having a newborn requiring NICU admission due to intrauterine growth retardation, preeclampsia, preterm birth, premature rupture of membranes, and asphyxia. The information about the prevalence of subsequent high-risk pregnancies was gathered via phone calls. Results: As the results indicated, heparin, progesterone, and aspirin were more frequently administered in the case group during subsequent pregnancies, compared to the control group (P

  16. Can the American High School become an Avenue of Advancement for All?

    Science.gov (United States)

    Balfanz, Robert

    2009-01-01

    As the twenty-first century opens, says Robert Balfanz, the United States is developing a deep social consensus that American high schools should ensure that all adolescents graduate from high school prepared for postsecondary schooling and training. Balfanz asks how well high schools are succeeding in this mission and whether they can ultimately…

  17. Time resolution performance studies of contemporary high speed photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.; Lo, C.C.

    1978-01-01

    The time resolution capabilities of prototype microchannel plate and static crossed-field photomultipliers have been investigated. Measurements were made of electron transit time, rise time, time response, single phtoelectron time spread and multiphotoelectron time spread for LEP HR350 proximity focused high gain curved microchannel plate and VPM-154A/1.6L static crossed-field photomultipliers. The experimental data have been compared with results obtained with conventionally designed high speed photomultipliers. Descriptions are given of both the measuring techniques and the measuring systems. 16 refs

  18. Monolayer Nickel Cobalt Hydroxyl Carbonate for High Performance All-Solid-State Asymmetric Supercapacitors.

    Science.gov (United States)

    Zhao, Yufeng; Ma, Hongnan; Huang, Shifei; Zhang, Xuejiao; Xia, Meirong; Tang, Yongfu; Ma, Zi-Feng

    2016-09-07

    The emergence of atomically thick nanolayer materials, which feature a short ion diffusion channel and provide more exposed atoms in the electrochemical reactions, offers a promising occasion to optimize the performance of supercapacitors on the atomic level. In this work, a novel monolayer Ni-Co hydroxyl carbonate with an average thickness of 1.07 nm is synthesized via an ordinary one-pot hydrothermal route for the first time. This unique monolayer structure can efficiently rise up the exposed electroactive sites and facilitate the surface dependent electrochemical reaction processes, and thus results in outstanding specific capacitance of 2266 F g(-1). Based on this material, an all-solid-state asymmetric supercapacitor is developed adopting alkaline PVA (poly(vinyl alcohol)) gel (PVA/KOH) as electrolyte, which performs remarkable cycling stability (no capacitance fade after 19 000 cycles) together with promising energy density of 50 Wh kg(-1) (202 μWh cm(-2)) and high power density of 8.69 kW kg(-1) (35.1 mW cm(-2)). This as-assembled all-solid-state asymmetric supercapacitor (AASC) holds great potential in the field of portable energy storage devices.

  19. Lightweight, Mesoporous, and Highly Absorptive All-Nanofiber Aerogel for Efficient Solar Steam Generation.

    Science.gov (United States)

    Jiang, Feng; Liu, He; Li, Yiju; Kuang, Yudi; Xu, Xu; Chen, Chaoji; Huang, Hao; Jia, Chao; Zhao, Xinpeng; Hitz, Emily; Zhou, Yubing; Yang, Ronggui; Cui, Lifeng; Hu, Liangbing

    2018-01-10

    The global fresh water shortage has driven enormous endeavors in seawater desalination and wastewater purification; among these, solar steam generation is effective in extracting fresh water by efficient utilization of naturally abundant solar energy. For solar steam generation, the primary focus is to design new materials that are biodegradable, sustainable, of low cost, and have high solar steam generation efficiency. Here, we designed a bilayer aerogel structure employing naturally abundant cellulose nanofibrils (CNFs) as basic building blocks to achieve sustainability and biodegradability as well as employing a carbon nanotube (CNT) layer for efficient solar utilization with over 97.5% of light absorbance from 300 to 1200 nm wavelength. The ultralow density (0.0096 g/cm 3 ) of the aerogel ensures that minimal material is required, reducing the production cost while at the same time satisfying the water transport and thermal-insulation requirements due to its highly porous structure (99.4% porosity). Owing to its rationally designed structure and thermal-regulation performance, the bilayer CNF-CNT aerogel exhibits a high solar-energy conversion efficiency of 76.3% and 1.11 kg m -2 h -1 at 1 kW m -2 (1 Sun) solar irradiation, comparable or even higher than most of the reported solar steam generation devices. Therefore, the all-nanofiber aerogel presents a new route for designing biodegradable, sustainable, and scalable solar steam generation devices with superb performance.

  20. Time resolution performance studies of contemporary high speed photomultipliers

    International Nuclear Information System (INIS)

    Leskovar, B.; Lo, C.C.

    1977-01-01

    The time resolution capabilities of prototype microchannel plate and static crossed-field photomultipliers have been investigated. Measurements were made of electron transit time, rise time, time response, single photoelectron time spread and multiphotoelectron time spread for LEP HR350 proximity focused high gain curved microchannel plate and VPM-154A/1.6L static crossed-field photomultipliers. The experimental data have been compared with results obtained with conventionally designed RCS 8850 and C31024 high speed photomultipliers. Descriptions are given of both the measuring techniques and the measuring systems

  1. 9 CFR 355.20 - Inspector to have access to plant at all times.

    Science.gov (United States)

    2010-01-01

    ... AND VOLUNTARY INSPECTION AND CERTIFICATION CERTIFIED PRODUCTS FOR DOGS, CATS, AND OTHER CARNIVORA... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Inspector to have access to plant at all times. 355.20 Section 355.20 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE...

  2. Generation of artificial time-histories, rich in all frequencies, from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1975-01-01

    In order to apply the time-history method of seismic analysis, it is often desirable to generate a suitable artificial time-history from a given response spectrum. The method described allows the generation of such a time-history that is also rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the adjacent frequencies have their half-power points overlap. The adjacent frequencies satisfy the condition that the frequency interval Δf near a given frequency f is such that (Δf)/f<2c/csub(c) where c is the damping of the system and csub(c) is the critical damping. In developing an artificial time-history, it is desirable to specify the envelope and duration of the record, very often in such a manner as to reproduce the envelope property of a specific earthquake record, and such an option is available in the method described. Examples are given of the development of typical artificial time-histories from earthquake design response spectra and from floor response spectra

  3. On the unification of all fundamental forces in a fundamentally fuzzy Cantorian ε(∞) manifold and high energy particle physics

    International Nuclear Information System (INIS)

    Marek-Crnjac, L.

    2004-01-01

    Quantum space time as given by topology and geometry of El Naschie's ε (∞) theory must be regarded as fundamentally fuzzy. It's geometry and topology belong to the mathematical category of fuzzy logic and fuzzy set theory. All lines are fuzzy fractal lines in fuzzy spaces and all exact values are exact fuzzy expectation values. That way we remove many paradoxes and contradictions in the standard model of high energy particle physics

  4. The Kavirondo Escarpment: a previously unrecognized site of high ...

    African Journals Online (AJOL)

    Despite only a limited effort there, we report several new atlas square occurrences, presence of the local and poorly known Rock Cisticola Cisticola emini and a significant range extension for the Stone Partridge Ptilopachus petrosus. Our short visits indicate high avian species richness is associated with the escarpment and ...

  5. Calculation of upper esophageal sphincter restitution time from high resolution manometry data using machine learning.

    Science.gov (United States)

    Jungheim, Michael; Busche, Andre; Miller, Simone; Schilling, Nicolas; Schmidt-Thieme, Lars; Ptok, Martin

    2016-10-15

    After swallowing, the upper esophageal sphincter (UES) needs a certain amount of time to return from maximum pressure to the resting condition. Disturbances of sphincter function not only during the swallowing process but also in this phase of pressure restitution may lead to globus sensation or dysphagia. Since UES pressures do not decrease in a linear or asymptotic manner, it is difficult to determine the exact time when the resting pressure is reached, even when using high resolution manometry (HRM). To overcome this problem a Machine Learning model was established to objectively determine the UES restitution time (RT) and moreover to collect physiological data on sphincter function after swallowing. HRM-data of 15 healthy participants performing 10 swallows each were included. After manual annotation of the RT interval by two swallowing experts, data were transferred to the Machine Learning model, which applied a sequence labeling modeling approach based on logistic regression to learn and objectivize the characteristics of all swallows. Individually computed RT values were then compared with the annotated values. Estimates of the RT were generated by the Machine Learning model for all 150 swallows. When annotated by swallowing experts mean RT of 11.16s±5.7 (SD) and 10.04s±5.74 were determined respectively, compared to model-generated values from 8.91s±3.71 to 10.87s±4.68 depending on model selection. The correlation score for the annotated RT of both examiners was 0.76 and 0.63 to 0.68 for comparison of model predicted values. Restitution time represents an important physiologic swallowing parameter not previously considered in HRM-studies of the UES, especially since disturbances of UES restitution may increase the risk of aspiration. The data presented here show that it takes approximately 9 to 11s for the UES to come to rest after swallowing. Based on maximal RT values, we demonstrate that an interval of 25-30s in between swallows is necessary until the

  6. Comparison of delay-interferometer and time-lens-based all-optical OFDM demultiplexers

    DEFF Research Database (Denmark)

    Lillieholm, Mads; Mulvad, Hans Christian Hansen; Galili, Michael

    2015-01-01

    ) based on time lenses. In the former scheme, cascaded delay-interferometers (DIs) are used to perform the O-DFT, with subsequent active optical gating to remove the intercarrier interference (ICI). Here a reduced-complexity partial O-DFT, realized by replacing a number of DIs with optical bandpass......In this paper we present the first detailed numerical comparison of two promising all-optical schemes to demultiplex orthogonal frequency-division multiplexing (OFDM) signals. The investigated schemes are the optical discrete Fourier transformation (O-DFT) and the optical spectral magnification (SM...... filters, is investigated. In the latter scheme the OFDM spectrum is magnified, allowing for simple optical bandpass filtering of the individual subcarriers with reduced ICI. Ideally only a single unit consisting of two time lenses is needed, reducing the complexity and potentially the energy consumption...

  7. Comparison of Delay-Interferometer and Time- Lens-Based All-Optical OFDM Demultiplexers

    DEFF Research Database (Denmark)

    Lillieholm, Mads; Mulvad, Hans Christian Hansen; Galili, Michael

    2015-01-01

    (SM) based on time lenses. In the former scheme, cascaded delay-interferometers (DIs) are used to perform the O-DFT, with subsequent active optical gating to remove the intercarrier interference (ICI). Here, a reduced-complexity partial O-DFT, realized by replacing a number of DIs with optical......In this letter, we present the first detailed numerical comparison of two promising all-optical schemes to demultiplex orthogonal frequency-division multiplexing (OFDM) signals. The investigated schemes are the optical discrete Fourier transformation (O-DFT) and the optical spectral magnification...... bandpass filters, is investigated. In the latter scheme, the OFDM spectrum is magnified, allowing for simple optical bandpass filtering of the individual subcarriers with reduced ICI. Ideally, only a single unit consisting of two time lenses is needed, reducing the complexity and potentially the energy...

  8. All-optical time-resolved measurement of laser energy modulation in a relativistic electron beam

    Directory of Open Access Journals (Sweden)

    D. Xiang

    2011-11-01

    Full Text Available We propose and demonstrate an all-optical method to measure laser energy modulation in a relativistic electron beam. In this scheme the time-dependent energy modulation generated from the electron-laser interaction in an undulator is converted into time-dependent density modulation with a chicane, which is measured to infer the laser energy modulation. The method, in principle, is capable of simultaneously providing information on femtosecond time scale and 10^{-5} energy scale not accessible with conventional methods. We anticipate that this method may have wide applications in many laser-based advanced beam manipulation techniques.

  9. Rapid simultaneous high-resolution mapping of myelin water fraction and relaxation times in human brain using BMC-mcDESPOT.

    Science.gov (United States)

    Bouhrara, Mustapha; Spencer, Richard G

    2017-02-15

    A number of central nervous system (CNS) diseases exhibit changes in myelin content and magnetic resonance longitudinal, T 1 , and transverse, T 2 , relaxation times, which therefore represent important biomarkers of CNS pathology. Among the methods applied for measurement of myelin water fraction (MWF) and relaxation times, the multicomponent driven equilibrium single pulse observation of T 1 and T 2 (mcDESPOT) approach is of particular interest. mcDESPOT permits whole brain mapping of multicomponent T 1 and T 2 , with data acquisition accomplished within a clinically realistic acquisition time. Unfortunately, previous studies have indicated the limited performance of mcDESPOT in the setting of the modest signal-to-noise range of high-resolution mapping, required for the depiction of small structures and to reduce partial volume effects. Recently, we showed that a new Bayesian Monte Carlo (BMC) analysis substantially improved determination of MWF from mcDESPOT imaging data. However, our previous study was limited in that it did not discuss determination of relaxation times. Here, we extend the BMC analysis to the simultaneous determination of whole-brain MWF and relaxation times using the two-component mcDESPOT signal model. Simulation analyses and in-vivo human brain studies indicate the overall greater performance of this approach compared to the stochastic region contraction (SRC) algorithm, conventionally used to derive parameter estimates from mcDESPOT data. SRC estimates of the transverse relaxation time of the long T 2 fraction, T 2,l , and the longitudinal relaxation time of the short T 1 fraction, T 1,s , clustered towards the lower and upper parameter search space limits, respectively, indicating failure of the fitting procedure. We demonstrate that this effect is absent in the BMC analysis. Our results also showed improved parameter estimation for BMC as compared to SRC for high-resolution mapping. Overall we find that the combination of BMC analysis

  10. Endovascular approach to treat ascending aortic pseudoaneurysm in a patient with previous CABG and very high surgical risk.

    Science.gov (United States)

    Zago, Alexandre C; Saadi, Eduardo K; Zago, Alcides J

    2011-10-01

    Pseudoaneurysm of the ascending aorta is an uncommon pathology and a challenge in high-risk patients who undergo conventional surgery because of high operative morbidity and mortality. Endovascular exclusion of an aortic pseudoaneurysm using an endoprosthesis is a less invasive approach, but few such cases have been reported. Moreover, the use of this approach poses unique therapeutic challenges because there is no specific endoprosthesis for ascending aortic repair, particularly to treat patients with previous coronary artery bypass graft (CABG). We describe the case of a 74-year-old patient who had undergone CABG and later presented with an iatrogenic ascending aortic pseudoaneurysm that occurred during an angiography. This patient was at very high risk for surgical treatment and, therefore, an endovascular approach was adopted: percutaneous coronary intervention for the left main coronary artery, left anterior descending and left circumflex native coronary arteries followed by endovascular endoprosthesis deployment in the ascending aorta to exclude the pseudoaneurysm. Both procedures were successfully performed, and the patient was discharged without complications 4 days later. At 5 months' clinical follow-up, his clinical condition was good and he had no complications. Copyright © 2011 Wiley-Liss, Inc.

  11. Prospective memory and its correlates and predictors in schizophrenia: an extension of previous findings.

    Science.gov (United States)

    Ungvari, Gabor S; Xiang, Yu-Tao; Tang, Wai-Kwong; Shum, David

    2008-09-01

    Prospective memory (PM) is the ability to remember to do something in the future without explicit prompts. Extending the number of subjects and the scope of our previously published study, this investigation examined the relationship between PM and socio-demographic and clinical factors, activities of daily living (ADL) and frontal lobe functions in patients with chronic schizophrenia. One hundred and ten Chinese schizophrenia patients, 60 from the previous study and 50 additional patients recruited for this study, and 110 matched healthy comparison subjects (HC) formed the study sample. Patients' clinical condition and activity of daily living were evaluated with the Brief Psychiatric Rating Scale (BPRS) and the Functional Needs Assessment (FNA). Time- and event-based PM tasks and three tests of prefrontal lobe functions (Design Fluency Test [DFT], Tower of London [TOL], Wisconsin Card Sorting Test [WCST]) were also administered. Patients' level of ADL and psychopathology were not associated with PM functions and only anticholinergic medications (ACM) showed a significant negative correlational relationship with PM tasks. Confirming the findings of the previous study, patients performed significantly more poorly on all two PM tasks than HC. Performance on time-based PM task significantly correlated with age, education level and DFT in HC and with age, DFT, TOL and WCST in patients. Patients' performance on the event-based PM correlated with DFT and one measure of WCST. In patients, TOL and age predicted the performance on time-based PM task; DFT and WCST predicted the event-based task. Involving a large sample of patients with matched controls, this study confirmed that PM is impaired in chronic schizophrenia. Deficient PM functions were related to prefrontal lobe dysfunction in both HC and patients but not to the patients' clinical condition, nor did they significantly affect ADL. ACMs determined certain aspects of PM.

  12. Generation of artificial time-histories, rich in all frequencies from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1975-01-01

    In order to apply the time-history method of seismic analysis, it is often desirable to generate a suitable artificial time-history from a given response spectrum. The method described in this paper allows the generation of such a time-history that is also rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the adjacent frequencies have their half-power points overlap. The adjacent frequencies satisfy the condition that the frequency interval Δf near a given frequency f is such that (Δf)/f<2c/csub(c) where c is the damping of the system and csub(c) is the critical damping. In developing an artificial time-history, it is desirable to specify the envelope and duration of the record, very often in such a manner as to reproduce the envelope property of a specific earthquake record, and such an option is available in the method described. Examples are given of the development of typical articifial time-histories from earthquake design response spectra and from floor response spectra. (Auth.)

  13. Outcomes With Edoxaban Versus Warfarin in Patients With Previous Cerebrovascular Events

    DEFF Research Database (Denmark)

    Rost, Natalia S; Giugliano, Robert P; Ruff, Christian T

    2016-01-01

    BACKGROUND AND PURPOSE: Patients with atrial fibrillation and previous ischemic stroke (IS)/transient ischemic attack (TIA) are at high risk of recurrent cerebrovascular events despite anticoagulation. In this prespecified subgroup analysis, we compared warfarin with edoxaban in patients with ver......BACKGROUND AND PURPOSE: Patients with atrial fibrillation and previous ischemic stroke (IS)/transient ischemic attack (TIA) are at high risk of recurrent cerebrovascular events despite anticoagulation. In this prespecified subgroup analysis, we compared warfarin with edoxaban in patients...... with versus without previous IS/TIA. METHODS: ENGAGE AF-TIMI 48 (Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) was a double-blind trial of 21 105 patients with atrial fibrillation randomized to warfarin (international normalized ratio......). Because only HDER is approved, we focused on the comparison of HDER versus warfarin. RESULTS: Of 5973 (28.3%) patients with previous IS/TIA, 67% had CHADS2 (congestive heart failure, hypertension, age, diabetes, prior stroke/transient ischemic attack) >3 and 36% were ≥75 years. Compared with 15 132...

  14. The Effects of the Previous Outcome on Probabilistic Choice in Rats

    Science.gov (United States)

    Marshall, Andrew T.; Kirkpatrick, Kimberly

    2014-01-01

    This study examined the effects of previous outcomes on subsequent choices in a probabilistic-choice task. Twenty-four rats were trained to choose between a certain outcome (1 or 3 pellets) versus an uncertain outcome (3 or 9 pellets), delivered with a probability of .1, .33, .67, and .9 in different phases. Uncertain outcome choices increased with the probability of uncertain food. Additionally, uncertain choices increased with the probability of uncertain food following both certain-choice outcomes and unrewarded uncertain choices. However, following uncertain-choice food outcomes, there was a tendency to choose the uncertain outcome in all cases, indicating that the rats continued to “gamble” after successful uncertain choices, regardless of the overall probability or magnitude of food. A subsequent manipulation, in which the probability of uncertain food varied within each session as a function of the previous uncertain outcome, examined how the previous outcome and probability of uncertain food affected choice in a dynamic environment. Uncertain-choice behavior increased with the probability of uncertain food. The rats exhibited increased sensitivity to probability changes and a greater degree of win–stay/lose–shift behavior than in the static phase. Simulations of two sequential choice models were performed to explore the possible mechanisms of reward value computations. The simulation results supported an exponentially decaying value function that updated as a function of trial (rather than time). These results emphasize the importance of analyzing global and local factors in choice behavior and suggest avenues for the future development of sequential-choice models. PMID:23205915

  15. Ultimate response time of high electron mobility transistors

    International Nuclear Information System (INIS)

    Rudin, Sergey; Rupper, Greg; Shur, Michael

    2015-01-01

    We present theoretical studies of the response time of the two-dimensional gated electron gas to femtosecond pulses. Our hydrodynamic simulations show that the device response to a short pulse or a step-function signal is either smooth or oscillating time-decay at low and high mobility, μ, values, respectively. At small gate voltage swings, U 0  = U g  − U th , where U g is the gate voltage and U th is the threshold voltage, such that μU 0 /L < v s , where L is the channel length and v s is the effective electron saturation velocity, the decay time in the low mobility samples is on the order of L 2 /(μU 0 ), in agreement with the analytical drift model. However, the decay is preceded by a delay time on the order of L/s, where s is the plasma wave velocity. This delay is the ballistic transport signature in collision-dominated devices, which becomes important during very short time periods. In the high mobility devices, the period of the decaying oscillations is on the order of the plasma wave velocity transit time. Our analysis shows that short channel field effect transistors operating in the plasmonic regime can meet the requirements for applications as terahertz detectors, mixers, delay lines, and phase shifters in ultra high-speed wireless communication circuits

  16. Event timing in high purity germanium coaxial detectors

    International Nuclear Information System (INIS)

    El-Ibiary, M.Y.

    1979-08-01

    The timing of gamma ray radiation in systems using high purity coaxial germanium detectors is analyzed and compared to that of systems using Ge(Li) detectors. The analysis takes into account the effect of the residual impurities on the electric field distribution, and hence on the rate of rise of the electrical pulses delivered to the timing module. Conditions under which the electric field distribution could lead to an improvement in timing performance, are identified. The results of the analysis confirm the experimental results published elsewhere and when compared with those for Ge(Li) detectors, which usually operate under conditions of charge carrier velocity saturation, confirm that high purity germanium detectors need not have inferior timing characteristics. A chart is given to provide a quantitative basis on which the trade off between the radius of the detector and its time resolution may be made

  17. Secondary recurrent miscarriage is associated with previous male birth.

    LENUS (Irish Health Repository)

    Ooi, Poh Veh

    2012-01-31

    Secondary recurrent miscarriage (RM) is defined as three or more consecutive pregnancy losses after delivery of a viable infant. Previous reports suggest that a firstborn male child is associated with less favourable subsequent reproductive potential, possibly due to maternal immunisation against male-specific minor histocompatibility antigens. In a retrospective cohort study of 85 cases of secondary RM we aimed to determine if secondary RM was associated with (i) gender of previous child, maternal age, or duration of miscarriage history, and (ii) increased risk of pregnancy complications. Fifty-three women (62.0%; 53\\/85) gave birth to a male child prior to RM compared to 32 (38.0%; 32\\/85) who gave birth to a female child (p=0.002). The majority (91.7%; 78\\/85) had uncomplicated, term deliveries and normal birth weight neonates, with one quarter of the women previously delivered by Caesarean section. All had routine RM investigations and 19.0% (16\\/85) had an abnormal result. Fifty-seven women conceived again and 33.3% (19\\/57) miscarried, but there was no significant difference in failure rates between those with a previous male or female child (13\\/32 vs. 6\\/25, p=0.2). When patients with abnormal results were excluded, or when women with only one previous child were considered, there was still no difference in these rates. A previous male birth may be associated with an increased risk of secondary RM but numbers preclude concluding whether this increases recurrence risk. The suggested association with previous male birth provides a basis for further investigations at a molecular level.

  18. Secondary recurrent miscarriage is associated with previous male birth.

    LENUS (Irish Health Repository)

    Ooi, Poh Veh

    2011-01-01

    Secondary recurrent miscarriage (RM) is defined as three or more consecutive pregnancy losses after delivery of a viable infant. Previous reports suggest that a firstborn male child is associated with less favourable subsequent reproductive potential, possibly due to maternal immunisation against male-specific minor histocompatibility antigens. In a retrospective cohort study of 85 cases of secondary RM we aimed to determine if secondary RM was associated with (i) gender of previous child, maternal age, or duration of miscarriage history, and (ii) increased risk of pregnancy complications. Fifty-three women (62.0%; 53\\/85) gave birth to a male child prior to RM compared to 32 (38.0%; 32\\/85) who gave birth to a female child (p=0.002). The majority (91.7%; 78\\/85) had uncomplicated, term deliveries and normal birth weight neonates, with one quarter of the women previously delivered by Caesarean section. All had routine RM investigations and 19.0% (16\\/85) had an abnormal result. Fifty-seven women conceived again and 33.3% (19\\/57) miscarried, but there was no significant difference in failure rates between those with a previous male or female child (13\\/32 vs. 6\\/25, p=0.2). When patients with abnormal results were excluded, or when women with only one previous child were considered, there was still no difference in these rates. A previous male birth may be associated with an increased risk of secondary RM but numbers preclude concluding whether this increases recurrence risk. The suggested association with previous male birth provides a basis for further investigations at a molecular level.

  19. Is Uric Acid a Missing Link between Previous Gestational Diabetes Mellitus and the Development of Type 2 Diabetes at a Later Time of Life?

    Science.gov (United States)

    Molęda, Piotr; Fronczyk, Aneta; Safranow, Krzysztof; Majkowska, Lilianna

    2016-01-01

    A high level of uric acid (UA) is a strong, independent risk factor for type 2 diabetes mellitus. The relationship between UA levels and the development of type 2 diabetes in women with previous gestational diabetes mellitus (pGDM) remains unclear. The aim of study was to evaluate the UA levels in pGDM women in relation to their current nutritional status and carbohydrate metabolism. 199 women with pGDM diagnoses based on oral glucose tolerance tests (OGTTs) 5-12 years previously and a control group of 50 women without pGDM. The assessment included anthropometric parameters, body composition (Tanita SC-330S), current OGTT, insulin resistance index (HOMA-IR), β-cell function (HOMA-%B), HbA1c, lipids, and uric acid. No differences between groups were found in terms of age, time from the index pregnancy, anthropometric parameters, lipids or creatinine levels. The incidences of overweight and obesity were similar. Carbohydrate abnormalities were more frequent in the pGDM group than the control group (43.2% vs 12.0% p1). The women with pGDM had significantly higher fasting glucose, HbA1c, glucose and insulin levels in the OGTTs, but similar HOMA-IR values. Their UA levels were significantly higher (258±58 vs 230±50 μmol/L, p1, p1), creatinine level (β = 0.23, 95% CI 0.11-0.35, pdiabetes (β = 0.13, 95% CI 0.01-0.25, pdiabetes) was statistically significant (odds ratio 3.62 [95% CI 1.8-7.3], p1). Higher UA levels may be associated with the development of type 2 diabetes in pGDM women, also in these with normal body weights.

  20. Kinota: An Open-Source NoSQL implementation of OGC SensorThings for large-scale high-resolution real-time environmental monitoring

    Science.gov (United States)

    Miles, B.; Chepudira, K.; LaBar, W.

    2017-12-01

    The Open Geospatial Consortium (OGC) SensorThings API (STA) specification, ratified in 2016, is a next-generation open standard for enabling real-time communication of sensor data. Building on over a decade of OGC Sensor Web Enablement (SWE) Standards, STA offers a rich data model that can represent a range of sensor and phenomena types (e.g. fixed sensors sensing fixed phenomena, fixed sensors sensing moving phenomena, mobile sensors sensing fixed phenomena, and mobile sensors sensing moving phenomena) and is data agnostic. Additionally, and in contrast to previous SWE standards, STA is developer-friendly, as is evident from its convenient JSON serialization, and expressive OData-based query language (with support for geospatial queries); with its Message Queue Telemetry Transport (MQTT), STA is also well-suited to efficient real-time data publishing and discovery. All these attributes make STA potentially useful for use in environmental monitoring sensor networks. Here we present Kinota(TM), an Open-Source NoSQL implementation of OGC SensorThings for large-scale high-resolution real-time environmental monitoring. Kinota, which roughly stands for Knowledge from Internet of Things Analyses, relies on Cassandra its underlying data store, which is a horizontally scalable, fault-tolerant open-source database that is often used to store time-series data for Big Data applications (though integration with other NoSQL or rational databases is possible). With this foundation, Kinota can scale to store data from an arbitrary number of sensors collecting data every 500 milliseconds. Additionally, Kinota architecture is very modular allowing for customization by adopters who can choose to replace parts of the existing implementation when desirable. The architecture is also highly portable providing the flexibility to choose between cloud providers like azure, amazon, google etc. The scalable, flexible and cloud friendly architecture of Kinota makes it ideal for use in next

  1. ASIC-enabled High Resolution Optical Time Domain Reflectometer

    Science.gov (United States)

    Skendzic, Sandra

    Fiber optics has become the preferred technology in communication systems because of what it has to offer: high data transmission rates, immunity to electromagnetic interference, and lightweight, flexible cables. An optical time domain reflectometer (OTDR) provides a convenient method of locating and diagnosing faults (e.g. break in a fiber) along a fiber that can obstruct crucial optical pathways. Both the ability to resolve the precise location of the fault and distinguish between two discrete, closely spaced faults are figures of merit. This thesis presents an implementation of a high resolution OTDR through the use of a compact and programmable ASIC (application specific integrated circuit). The integration of many essential OTDR functions on a single chip is advantageous over existing commercial instruments because it enables small, lightweight packaging, and offers low power and cost efficiency. Furthermore, its compactness presents the option of placing multiple ASICs in parallel, which can conceivably ease the characterization of densely populated fiber optic networks. The OTDR ASIC consists of a tunable clock, pattern generator, precise timer, electrical receiver, and signal sampling circuit. During OTDR operation, the chip generates narrow electrical pulse, which can then be converted to optical format when coupled with an external laser diode driver. The ASIC also works with an external photodetector to measure the timing and amplitude of optical reflections in a fiber. It has a 1 cm sampling resolution, which allows for a 2 cm spatial resolution. While this OTDR ASIC has been previously demonstrated for multimode fiber fault diagnostics, this thesis focuses on extending its functionality to single mode fiber. To validate this novel approach to OTDR, this thesis is divided into five chapters: (1) introduction, (2) implementation, (3), performance of ASIC-based OTDR, (4) exploration in optical pre-amplification with a semiconductor optical amplifier, and

  2. All-Digital Time-Domain CMOS Smart Temperature Sensor with On-Chip Linearity Enhancement.

    Science.gov (United States)

    Chen, Chun-Chi; Chen, Chao-Lieh; Lin, Yi

    2016-01-30

    This paper proposes the first all-digital on-chip linearity enhancement technique for improving the accuracy of the time-domain complementary metal-oxide semiconductor (CMOS) smart temperature sensor. To facilitate on-chip application and intellectual property reuse, an all-digital time-domain smart temperature sensor was implemented using 90 nm Field Programmable Gate Arrays (FPGAs). Although the inverter-based temperature sensor has a smaller circuit area and lower complexity, two-point calibration must be used to achieve an acceptable inaccuracy. With the help of a calibration circuit, the influence of process variations was reduced greatly for one-point calibration support, reducing the test costs and time. However, the sensor response still exhibited a large curvature, which substantially affected the accuracy of the sensor. Thus, an on-chip linearity-enhanced circuit is proposed to linearize the curve and achieve a new linearity-enhanced output. The sensor was implemented on eight different Xilinx FPGA using 118 slices per sensor in each FPGA to demonstrate the benefits of the linearization. Compared with the unlinearized version, the maximal inaccuracy of the linearized version decreased from 5 °C to 2.5 °C after one-point calibration in a range of -20 °C to 100 °C. The sensor consumed 95 μW using 1 kSa/s. The proposed linearity enhancement technique significantly improves temperature sensing accuracy, avoiding costly curvature compensation while it is fully synthesizable for future Very Large Scale Integration (VLSI) system.

  3. The Time Structure of Hadronic Showers in Highly Granular Calorimeters with Tungsten and Steel Absorbers

    CERN Document Server

    Adloff, C.; Chefdeville, M.; Drancourt, C.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Koletsou, I.; Prast, J.; Vouters, G.; Repond, J.; Schlereth, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S.T.; Sosebee, M.; White, A.P.; Yu, J.; Eigen, G.; Thomson, M.A.; Ward, D.R.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Arfaoui, A.; Benoit, M.; Dannheim, D.; Elsener, K.; Folger, G.; Grefe, C.; Ivantchenko, V.; Killenberg, M.; Klempt, W.; van der Kraaij, E.; Linssen, L.; Lucaci-Timoce, A.-I.; Münnich, A.; Poss, S.; Ribon, A.; Roloff, P.; Sailer, A.; Schlatter, D.; Sicking, E.; Strube, J.; Uzhinskiy, V.; Carloganu, C.; Gay, P.; Manen, S.; Royer, L.; Cornett, U.; David, D.; Ebrahimi, A.; Falley, G.; Feege, N.; Gadow, K.; Göttlicher, P.; Günter, C.; Hartbrich, O.; Hermberg, B.; Karstensen, S.; Krivan, F.; Krüger, K.; Lu, S.; Lutz, B.; Morozov, S.; Morgunov, V.; Neubüser, C.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Fagot, A.; Tytgat, M.; Zaganidis, N.; Hostachy, J.-Y.; Morin, L.; Garutti, E.; Laurien, S.; Marchesini, I.; Matysek, M.; Ramilli, M.; Briggl, K.; Eckert, P.; Harion, T.; Schultz-Coulon, H.-Ch.; Shen, W.; Stamen, R.; Chang, S.; Khan, A.; Kim, D.H.; Kong, D.J.; Oh, Y.D.; Bilki, B.; Norbeck, E.; Northacker, D.; Onel, Y.; Wilson, G.W.; Kawagoe, K.; Miyazaki, Y.; Sudo, Y.; Ueno, H.; Yoshioka, T.; Dauncey, P.D.; Cortina Gil, E.; Mannai, S.; Baulieu, G.; Calabria, P.; Caponetto, L.; Combaret, C.; Della Negra, R.; Ete, R.; Grenier, G.; Han, R.; Ianigro, J-C.; Kieffer, R.; Laktineh, I.; Lumb, N.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Tromeur, W.; Vander Donckt, M.; Zoccarato, Y.; Berenguer Antequera, J.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Corriveau, F.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Rusinov, V.; Tarkovsky, E.; Kozlov, V.; Soloviev, Y.; Besson, D.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Popova, E.; Tikhomirov, V.; Gabriel, M.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Szalay, M.; Tesar, M.; Weuste, L.; Amjad, M.S.; Bonis, J.; Conforti di Lorenzo, S.; Cornebise, P.; Fleury, J.; Frisson, T.; van der Kolk, N.; Richard, F.; Pöschl, R.; Rouene, J.; Anduze, M.; Balagura, V.; Becheva, E.; Boudry, V.; Brient, J-C.; Cornat, R.; Frotin, M.; Gastaldi, F.; Guliyev, E.; Haddad, Y.; Magniette, F.; Ruan, M.; Tran, T.H.; Videau, H.; Callier, S.; Dulucq, F.; Martin-Chassard, G.; de la Taille, Ch.; Raux, L.; Seguin-Moreau, N.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Kotera, K.; Ono, H.; Takeshita, T.; Uozumi, S.; Chai, J.S.; Song, H.S.; Lee, S.H.; Götze, M.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2014-01-01

    The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.

  4. Prevalence of abnormal Pap smears in a consecutive and previously unscreened population in Romania.

    Science.gov (United States)

    Stolnicu, Simona; Musca, Simona; Micu, Dorian; Micu, Luminita; Moldovan, Cosmin; Puscasiu, Lucian

    2014-02-01

    To determine the prevalence of abnormal cervical smears in a previously unscreened and asymptomatic population in Romania and to compare the data with those from other countries in Europe. In a retrospective study, data were reviewed from smears obtained from women in Romania who had been referred to the gynecologist between January 2006 and December 2011. The smears were collected through 3 regional opportunistic programs of cervical screening and were classified according to the Bethesda system. During the study period, 50536 smear tests were carried out. Of these, 100 smears (0.2%) were unsatisfactory and excluded from the study. Among the remaining 50436 smears, 2965 patients (5.9%) had abnormal epithelial changes. Most of the abnormal smears were represented by atypical squamous cells of undetermined significance (2.6% of all smears). The data confirmed that there is a high prevalence of high-grade intraepithelial squamous-type lesions (0.9% of all smears) in Romania, and of abnormal smears in women younger than 25years of age (14.0% of all abnormal smears). The data show that there is a high prevalence of epithelial abnormalities among cervical smears in Romania compared with other European countries that run a national screening program. © 2013.

  5. Effects of high CO{sub 2} seawater on the copepod (Acartia tsuensis) through all life stages and subsequent generations

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Haruko [Institute for East China Sea Research, Nagasaki University, 1551-7 Tairamachi, Nagasaki 851-2213 (Japan)], E-mail: harukoku@e-mail.jp; Ishimatsu, Atsushi [Institute for East China Sea Research, Nagasaki University, 1551-7 Tairamachi, Nagasaki 851-2213 (Japan)

    2008-06-15

    We studied the effects of exposure to seawater equilibrated with CO{sub 2}-enriched air (CO{sub 2} 2380 ppm) from eggs to maturity and over two subsequent generations on the copepod Acartia tsuensis. Compared to the control (CO{sub 2} 380 ppm), high CO{sub 2} exposure through all life stages of the 1st generation copepods did not significantly affect survival, body size or developmental speed. Egg production and hatching rates were also not significantly different between the initial generation of females exposed to high CO{sub 2} and the 1st and 2nd generation females developed from eggs to maturity in high CO{sub 2}. Thus, the copepods appear more tolerant to increased CO{sub 2} than other marine organisms previously investigated for CO{sub 2} tolerance (i.e., sea urchins and bivalves). However, the crucial importance of copepods in marine ecosystems requires thorough evaluation of the overall impacts of marine environmental changes predicted to occur with increased CO{sub 2} concentrations, i.e., increased temperature, enhanced UV irradiation, and changes in the community structure and nutritional value of phytoplankton.

  6. Simulation design of P–I–N-type all-perovskite solar cells with high efficiency

    International Nuclear Information System (INIS)

    Du Hui-Jing; Wang Wei-Chao; Gu Yi-Fan

    2017-01-01

    According to the good charge transporting property of perovskite, we design and simulate a p–i–n-type all-perovskite solar cell by using one-dimensional device simulator. The perovskite charge transporting layers and the perovskite absorber constitute the all-perovskite cell. By modulating the cell parameters, such as layer thickness values, doping concentrations and energy bands of n-, i-, and p-type perovskite layers, the all-perovskite solar cell obtains a high power conversion efficiency of 25.84%. The band matched cell shows appreciably improved performance with widen absorption spectrum and lowered recombination rate, so weobtain a high J sc of 32.47 mA/cm 2 . The small series resistance of the all-perovskite solar cell also benefits the high J sc . The simulation provides a novel thought of designing perovskite solar cells with simple producing process, low production cost and high efficient structure to solve the energy problem. (paper)

  7. Rapid fish stock depletion in previously unexploited seamounts: the ...

    African Journals Online (AJOL)

    Rapid fish stock depletion in previously unexploited seamounts: the case of Beryx splendens from the Sierra Leone Rise (Gulf of Guinea) ... A spectral analysis and red-noise spectra procedure (REDFIT) algorithm was used to identify the red-noise spectrum from the gaps in the observed time-series of catch per unit effort by ...

  8. The Fast Tracker Real Time Processor: high quality real-time tracking at ATLAS

    CERN Document Server

    Stabile, A; The ATLAS collaboration

    2011-01-01

    As the LHC luminosity is ramped up to the design level of 1x1034 cm−2 s−1 and beyond, the high rates, multiplicities, and energies of particles seen by the detectors will pose a unique challenge. Only a tiny fraction of the produced collisions can be stored on tape and immense real-time data reduction is needed. An effective trigger system must maintain high trigger efficiencies for the most important physics and at the same time suppress the enormous QCD backgrounds. This requires massive computing power to minimize the online execution time of complex algorithms. A multi-level trigger is an effective solution for an otherwise impossible problem. The Fast Tracker (FTK)[1], [2] is a proposed upgrade to the current ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK is a dedicated Super Computer based on a mixture of advanced technologies. The architecture broadly employs powerf...

  9. High Time Resolution Astrophysics

    CERN Document Server

    Phelan, Don; Shearer, Andrew

    2008-01-01

    High Time Resolution Astrophysics (HTRA) is an important new window to the universe and a vital tool in understanding a range of phenomena from diverse objects and radiative processes. This importance is demonstrated in this volume with the description of a number of topics in astrophysics, including quantum optics, cataclysmic variables, pulsars, X-ray binaries and stellar pulsations to name a few. Underlining this science foundation, technological developments in both instrumentation and detectors are described. These instruments and detectors combined cover a wide range of timescales and can measure fluxes, spectra and polarisation. These advances make it possible for HTRA to make a big contribution to our understanding of the Universe in the next decade.

  10. Real-time monitoring of viscosity changes triggered by chemical reactions using a high-speed imaging method

    Directory of Open Access Journals (Sweden)

    Wooseok Jung

    2015-09-01

    Full Text Available We present a method to monitor in real time peptide self-assembly or polymerization events. The temperature controlled modification of a previously reported splash test setup using high speed imaging enables to observe and measure rheological changes in liquid samples and can, in turn, monitor a peptide self-assembly or polymerization reaction accompanied with specific changes in solution viscosity. A series of 2 mm glass beads were dropped into an Fmoc-L3-OMe (methylated Fluorenylmethyloxycarbonyl-trileucine solution mixed with Alcalase 2.4 L (EC 3.4.21.62 or first dipped in Tetramethylethylenediamine (TEMED, a catalyst for acrylamide polymerization, then dropped into acrylamide. The resulting splashes were observed using a high speed camera. The results demonstrate that the viscosity changes of the peptide sample during the peptide self-assembly or acrylamide polymerization affect the specific shape and evolution of the splashing event. Typically, the increase in viscosity while the reaction occurs decreased the size of the splash and the amount of time for the splash to reach maximum extension from the moment for the beads to impact the sample. The ability to observe rheological changes of sample state presents the opportunity to monitor the real time dynamics of peptide self-assembly or cross-polymerization. Keywords: High-speed imaging, Self-assembly, Viscosity sensor

  11. Kidnapping Detection and Recognition in Previous Unknown Environment

    Directory of Open Access Journals (Sweden)

    Yang Tian

    2017-01-01

    Full Text Available An unaware event referred to as kidnapping makes the estimation result of localization incorrect. In a previous unknown environment, incorrect localization result causes incorrect mapping result in Simultaneous Localization and Mapping (SLAM by kidnapping. In this situation, the explored area and unexplored area are divided to make the kidnapping recovery difficult. To provide sufficient information on kidnapping, a framework to judge whether kidnapping has occurred and to identify the type of kidnapping with filter-based SLAM is proposed. The framework is called double kidnapping detection and recognition (DKDR by performing two checks before and after the “update” process with different metrics in real time. To explain one of the principles of DKDR, we describe a property of filter-based SLAM that corrects the mapping result of the environment using the current observations after the “update” process. Two classical filter-based SLAM algorithms, Extend Kalman Filter (EKF SLAM and Particle Filter (PF SLAM, are modified to show that DKDR can be simply and widely applied in existing filter-based SLAM algorithms. Furthermore, a technique to determine the adapted thresholds of metrics in real time without previous data is presented. Both simulated and experimental results demonstrate the validity and accuracy of the proposed method.

  12. Factor VIII brand and the incidence of factor VIII inhibitors in previously untreated UK children with severe hemophilia A, 2000-2011

    Science.gov (United States)

    Palmer, Benedict P.; Chalmers, Elizabeth A.; Hart, Daniel P.; Liesner, Ri; Rangarajan, Savita; Talks, Katherine; Williams, Michael; Hay, Charles R. M.

    2014-01-01

    The effect of recombinant factor VIII (rFVIII) brand on inhibitor development was investigated in all 407 severe hemophilia A previously untreated patients born in the United Kingdom (UK) between 1 January 2000 and 31 December 2011. Eighty-eight (22%) had been in the RODIN study. Information was extracted from the National Haemophilia Database. Because exposure days (EDs) were not known for some patients, time from first treatment was used as a surrogate for rFVIII exposure. An inhibitor developed in 118 (29%) patients, 60 high and 58 low titer, after a median (interquartile range) of 7.8 (3.3-13.5) months from first exposure and 16 (9-30) EDs. Of 128 patients treated with Kogenate Bayer/Helixate NexGen, 45 (35.2%, 95% confidence interval [CI] 27.4-43.8) developed an inhibitor compared with 42/172 (24.4%, 95% CI 18.6% to 31.4%) with Advate (P = .04). The adjusted hazard ratio (HR) (95% CI) for Kogenate Bayer/Helixate NexGen compared with Advate was 2.14 (1.12-4.10) (P = .02) for high titer and 1.75 (1.11-2.76) (P = .02) for all inhibitors. When excluding UK-RODIN patients, the adjusted HR (95% CI) for high-titer inhibitors was 2.00 (0.93-4.34) (P = .08). ReFacto AF was associated with a higher incidence of all, but not high-titer, inhibitors than Advate. These results will help inform debate around the relative immunogenicity and use of rFVIII brands. PMID:25339360

  13. Highly Flexible Freestanding Porous Carbon Nanofibers for Electrodes Materials of High-Performance All-Carbon Supercapacitors.

    Science.gov (United States)

    Liu, Ying; Zhou, Jinyuan; Chen, Lulu; Zhang, Peng; Fu, Wenbin; Zhao, Hao; Ma, Yufang; Pan, Xiaojun; Zhang, Zhenxing; Han, Weihua; Xie, Erqing

    2015-10-28

    Highly flexible porous carbon nanofibers (P-CNFs) were fabricated by electrospining technique combining with metal ion-assistant acid corrosion process. The resultant fibers display high conductivity and outstanding mechanical flexibility, whereas little change in their resistance can be observed under repeatedly bending, even to 180°. Further results indicate that the improved flexibility of P-CNFs can be due to the high graphitization degree caused by Co ions. In view of electrode materials for high-performance supercapacitors, this type of porous nanostructure and high graphitization degree could synergistically facilitate the electrolyte ion diffusion and electron transportation. In the three electrodes testing system, the resultant P-CNFs electrodes can exhibit a specific capacitance of 104.5 F g(-1) (0.2 A g(-1)), high rate capability (remain 56.5% at 10 A g(-1)), and capacitance retention of ∼94% after 2000 cycles. Furthermore, the assembled symmetric supercapacitors showed a high flexibility and can deliver an energy density of 3.22 Wh kg(-1) at power density of 600 W kg(-1). This work might open a way to improve the mechanical properties of carbon fibers and suggests that this type of freestanding P-CNFs be used as effective electrode materials for flexible all-carbon supercapacitors.

  14. The NANOGrav 11-year Data Set: High-precision Timing of 45 Millisecond Pulsars

    Science.gov (United States)

    Arzoumanian, Zaven; Brazier, Adam; Burke-Spolaor, Sarah; Chamberlin, Sydney; Chatterjee, Shami; Christy, Brian; Cordes, James M.; Cornish, Neil J.; Crawford, Fronefield; Thankful Cromartie, H.; Crowter, Kathryn; DeCesar, Megan E.; Demorest, Paul B.; Dolch, Timothy; Ellis, Justin A.; Ferdman, Robert D.; Ferrara, Elizabeth C.; Fonseca, Emmanuel; Garver-Daniels, Nathan; Gentile, Peter A.; Halmrast, Daniel; Huerta, E. A.; Jenet, Fredrick A.; Jessup, Cody; Jones, Glenn; Jones, Megan L.; Kaplan, David L.; Lam, Michael T.; Lazio, T. Joseph W.; Levin, Lina; Lommen, Andrea; Lorimer, Duncan R.; Luo, Jing; Lynch, Ryan S.; Madison, Dustin; Matthews, Allison M.; McLaughlin, Maura A.; McWilliams, Sean T.; Mingarelli, Chiara; Ng, Cherry; Nice, David J.; Pennucci, Timothy T.; Ransom, Scott M.; Ray, Paul S.; Siemens, Xavier; Simon, Joseph; Spiewak, Renée; Stairs, Ingrid H.; Stinebring, Daniel R.; Stovall, Kevin; Swiggum, Joseph K.; Taylor, Stephen R.; Vallisneri, Michele; van Haasteren, Rutger; Vigeland, Sarah J.; Zhu, Weiwei; The NANOGrav Collaboration

    2018-04-01

    We present high-precision timing data over time spans of up to 11 years for 45 millisecond pulsars observed as part of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) project, aimed at detecting and characterizing low-frequency gravitational waves. The pulsars were observed with the Arecibo Observatory and/or the Green Bank Telescope at frequencies ranging from 327 MHz to 2.3 GHz. Most pulsars were observed with approximately monthly cadence, and six high-timing-precision pulsars were observed weekly. All were observed at widely separated frequencies at each observing epoch in order to fit for time-variable dispersion delays. We describe our methods for data processing, time-of-arrival (TOA) calculation, and the implementation of a new, automated method for removing outlier TOAs. We fit a timing model for each pulsar that includes spin, astrometric, and (for binary pulsars) orbital parameters; time-variable dispersion delays; and parameters that quantify pulse-profile evolution with frequency. The timing solutions provide three new parallax measurements, two new Shapiro delay measurements, and two new measurements of significant orbital-period variations. We fit models that characterize sources of noise for each pulsar. We find that 11 pulsars show significant red noise, with generally smaller spectral indices than typically measured for non-recycled pulsars, possibly suggesting a different origin. A companion paper uses these data to constrain the strength of the gravitational-wave background.

  15. Generation of artificial time-histories, rich in all frequencies, from given response spectra

    International Nuclear Information System (INIS)

    Levy, S.; Wilkinson, J.P.D.

    1976-01-01

    In the design of nuclear power plants, it has been found desirable in certain instances to use the time-history method of dynamic analysis to determine the plant response to seismic input. In the implementation of this method, it is necessary to determine an adequate representation of the excitation as a function of time. Because many design criteria are specified in terms of design response spectra one is faced with the problem of generating a time-history whose own response spectrum approximates as far as possible to the originally specified design response spectrum. One objective of this paper is to present a method of synthesizing such time-histories from a given design response spectrum. The design response spectra may be descriptive of floor responses at a particular location in a plant, or they may be descriptive of seismic ground motions at a plant site. The method described in this paper allows the generation of time histories that are rich in all frequencies in the spectrum. This richness is achieved by choosing a large number of closely-spaced frequency points such that the half-power points of adjacent frequencies overlap. Examples are given concerning seismic design response spectra, and a number of points are discussed concerning the effect of frequency spacing on convergence. (Auth.)

  16. SynUTC - high precision time synchronization over ethernet networks

    CERN Document Server

    Höller, R; Horauer, M; Kerö, N; Schmid, U; Schossmaier, K

    2002-01-01

    This article describes our SynUTC (Synchronized Universal Time Coordinated) technology, which enables high-accuracy distribution of GPS time and time synchronization of network nodes connected via standard Ethernet LANs. By means of exchanging data packets in conjunction with moderate hardware support at nodes and switches, an overall worst-case accuracy in the range of some 100 ns can be achieved, with negligible communication overhead. Our technology thus improves the 1 ms-range accuracy achievable by conventional, software-based approaches like NTP by 4 orders of magnitude. Applications can use the high-accuracy global time provided by SynUTC for event timestamping and event generation both at hardware and software level. SynUTC is based upon inserting highly accurate time information into dedicated data packets at the media-independent interface (MII) between the physical layer transceiver and the network controller upon packet transmission and reception, respectively. As a consequence, every node has acc...

  17. Attribute and topology based change detection in a constellation of previously detected objects

    Science.gov (United States)

    Paglieroni, David W.; Beer, Reginald N.

    2016-01-19

    A system that applies attribute and topology based change detection to networks of objects that were detected on previous scans of a structure, roadway, or area of interest. The attributes capture properties or characteristics of the previously detected objects, such as location, time of detection, size, elongation, orientation, etc. The topology of the network of previously detected objects is maintained in a constellation database that stores attributes of previously detected objects and implicitly captures the geometrical structure of the network. A change detection system detects change by comparing the attributes and topology of new objects detected on the latest scan to the constellation database of previously detected objects.

  18. A Pan-Lyssavirus Taqman Real-Time RT-PCR Assay for the Detection of Highly Variable Rabies virus and Other Lyssaviruses.

    Science.gov (United States)

    Wadhwa, Ashutosh; Wilkins, Kimberly; Gao, Jinxin; Condori Condori, Rene Edgar; Gigante, Crystal M; Zhao, Hui; Ma, Xiaoyue; Ellison, James A; Greenberg, Lauren; Velasco-Villa, Andres; Orciari, Lillian; Li, Yu

    2017-01-01

    Rabies, resulting from infection by Rabies virus (RABV) and related lyssaviruses, is one of the most deadly zoonotic diseases and is responsible for up to 70,000 estimated human deaths worldwide each year. Rapid and accurate laboratory diagnosis of rabies is essential for timely administration of post-exposure prophylaxis in humans and control of the disease in animals. Currently, only the direct fluorescent antibody (DFA) test is recommended for routine rabies diagnosis. Reverse-transcription polymerase chain reaction (RT-PCR) based diagnostic methods have been widely adapted for the diagnosis of other viral pathogens, but there is currently no widely accepted rapid real-time RT-PCR assay for the detection of all lyssaviruses. In this study, we demonstrate the validation of a newly developed multiplex real-time RT-PCR assay named LN34, which uses a combination of degenerate primers and probes along with probe modifications to achieve superior coverage of the Lyssavirus genus while maintaining sensitivity and specificity. The primers and probes of the LN34 assay target the highly conserved non-coding leader region and part of the nucleoprotein (N) coding sequence of the Lyssavirus genome to maintain assay robustness. The probes were further modified by locked nucleotides to increase their melting temperature to meet the requirements for an optimal real-time RT-PCR assay. The LN34 assay was able to detect all RABV variants and other lyssaviruses in a validation panel that included representative RABV isolates from most regions of the world as well as representatives of 13 additional Lyssavirus species. The LN34 assay was successfully used for both ante-mortem and post-mortem diagnosis of over 200 clinical samples as well as field derived surveillance samples. This assay represents a major improvement over previously published rabies specific RT-PCR and real-time RT-PCR assays because of its ability to universally detect RABV and other lyssaviruses, its high

  19. A Pan-Lyssavirus Taqman Real-Time RT-PCR Assay for the Detection of Highly Variable Rabies virus and Other Lyssaviruses.

    Directory of Open Access Journals (Sweden)

    Ashutosh Wadhwa

    2017-01-01

    Full Text Available Rabies, resulting from infection by Rabies virus (RABV and related lyssaviruses, is one of the most deadly zoonotic diseases and is responsible for up to 70,000 estimated human deaths worldwide each year. Rapid and accurate laboratory diagnosis of rabies is essential for timely administration of post-exposure prophylaxis in humans and control of the disease in animals. Currently, only the direct fluorescent antibody (DFA test is recommended for routine rabies diagnosis. Reverse-transcription polymerase chain reaction (RT-PCR based diagnostic methods have been widely adapted for the diagnosis of other viral pathogens, but there is currently no widely accepted rapid real-time RT-PCR assay for the detection of all lyssaviruses. In this study, we demonstrate the validation of a newly developed multiplex real-time RT-PCR assay named LN34, which uses a combination of degenerate primers and probes along with probe modifications to achieve superior coverage of the Lyssavirus genus while maintaining sensitivity and specificity. The primers and probes of the LN34 assay target the highly conserved non-coding leader region and part of the nucleoprotein (N coding sequence of the Lyssavirus genome to maintain assay robustness. The probes were further modified by locked nucleotides to increase their melting temperature to meet the requirements for an optimal real-time RT-PCR assay. The LN34 assay was able to detect all RABV variants and other lyssaviruses in a validation panel that included representative RABV isolates from most regions of the world as well as representatives of 13 additional Lyssavirus species. The LN34 assay was successfully used for both ante-mortem and post-mortem diagnosis of over 200 clinical samples as well as field derived surveillance samples. This assay represents a major improvement over previously published rabies specific RT-PCR and real-time RT-PCR assays because of its ability to universally detect RABV and other lyssaviruses

  20. Time-separated oscillatory fields for high-precision mass measurements on short-lived Al and Ca nuclides

    CERN Document Server

    George, Simon; Blank, B.; Blaum, K.; Breitenfeldt, M.; Hager, U.; Herfurth, F.; Herlert, A.; Kellerbauer, A.; Kluge, H.J.; Kretzschmar, M.; Lunney, D.; Savreux, R.; Schwarz, Andreas S.; Schweikhard, L.; Yazidjian, C.

    2008-01-01

    High-precision Penning trap mass measurements on the stable nuclide $^{27}$Al as well as on the short-lived radionuclides $^{26}$Al and $^{38,39}$Ca have been performed by use of radio-frequency excitation with time-separated oscillatory fields, i.e. Ramsey's method, as recently introduced for the excitation of the ion motion in a Penning trap, was applied. A comparison with the conventional method of a single continuous excitation demonstrates its advantage of up to ten times shorter measurements. The new mass values of $^{26,27}$Al clarify conflicting data in this specific mass region. In addition, the resulting mass values of the superallowed $\\beta$-emitter $^{38}$Ca as well as of the groundstate of the $\\beta$-emitter $^{26}$Al$^{m}$ confirm previous measurements and corresponding theoretical corrections of the ft-values.

  1. Reverse arthroplasty for osteoarthritis and rotator cuff deficiency after previous surgery for recurrent anterior shoulder instability.

    Science.gov (United States)

    Raiss, Patric; Zeifang, Felix; Pons-Villanueva, Juan; Smithers, Christopher J; Loew, Markus; Walch, Gilles

    2014-07-01

    Osteoarthritis in combination with rotator cuff deficiency following previous shoulder stabilisation surgery and after failed surgical treatment for chronic anterior shoulder dislocation is a challenging condition. The aim of this study was to analyse the results of reverse shoulder arthroplasty in such patients. Thirteen patients with a median follow-up of 3.5 (range two to eight) years and a median age of 70 (range 48-82) years were included. In all shoulders a tear of at least one rotator cuff tendon in combination with osteoarthritis was present at the time of arthroplasty. The Constant score, shoulder flexion and external and internal rotation with the elbow at the side were documented pre-operatively and at the final follow-up. Pre-operative, immediate post-operative and final follow-up radiographs were analysed. All complications and revisions were documented. Twelve patients were either satisfied or very satisfied with the procedure. The median Constant score increased from 26 points pre-operatively to 67 points at the final follow-up (p = 0.001). The median shoulder flexion increased significantly from 70° to 130° and internal rotation from two to four points (p = 0.002). External rotation did not change significantly (p = 0.55). Glenoid notching was present in five cases and was graded as mild in three cases and moderate in two. One complication occurred leading to revision surgery. Reverse arthroplasty leads to high satisfaction rates for patients with osteoarthritis and rotator cuff deficiency who had undergone previous shoulder stabilisation procedures. The improvements in clinical outcome as well as the radiographic results seem to be comparable with those of other studies reporting on the outcome of reverse shoulder arthroplasty for other conditions.

  2. All 2D materials as electrodes for high power hybrid energy storage applications

    Science.gov (United States)

    Kato, Keiko; Sayed, Farheen N.; Babu, Ganguli; Ajayan, Pulickel M.

    2018-04-01

    Achieving both high energy and power densities from energy storage devices is a core strategy to meet the increasing demands of high performance portable electronics and electric transportation systems. Li-ion capacitor is a promising hybrid technology that strategically exploits high energy density from a Li-ion battery electrode and high power density from a supercapacitor electrode. However, the performance and safety of hybrid devices are still major concerns due to the use of graphite anodes which form passivation layers with organic electrolytes at lower potentials. Here, we explore 2D nanosheets as both anode and cathode electrodes to build a high power system without compromising energy density. Owing to the high electrical conductivity and multivalent redox activity at higher potentials, the Li-ion intercalation electrode is capable of maintaining large energy density at higher current rates with less safety risk than conventional systems. Hybrid devices consisting of all in all 2D electrodes deliver energy density as high as 121 Wh g-1 (at 240 W kg-1) and retains 29 Wh g-1 at high power density of 3600 W kg-1.

  3. Subsequent childbirth after a previous traumatic birth.

    Science.gov (United States)

    Beck, Cheryl Tatano; Watson, Sue

    2010-01-01

    Nine percent of new mothers in the United States who participated in the Listening to Mothers II Postpartum Survey screened positive for meeting the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria for posttraumatic stress disorder after childbirth. Women who have had a traumatic birth experience report fewer subsequent children and a longer length of time before their second baby. Childbirth-related posttraumatic stress disorder impacts couples' physical relationship, communication, conflict, emotions, and bonding with their children. The purpose of this study was to describe the meaning of women's experiences of a subsequent childbirth after a previous traumatic birth. Phenomenology was the research design used. An international sample of 35 women participated in this Internet study. Women were asked, "Please describe in as much detail as you can remember your subsequent pregnancy, labor, and delivery following your previous traumatic birth." Colaizzi's phenomenological data analysis approach was used to analyze the stories of the 35 women. Data analysis yielded four themes: (a) riding the turbulent wave of panic during pregnancy; (b) strategizing: attempts to reclaim their body and complete the journey to motherhood; (c) bringing reverence to the birthing process and empowering women; and (d) still elusive: the longed-for healing birth experience. Subsequent childbirth after a previous birth trauma has the potential to either heal or retraumatize women. During pregnancy, women need permission and encouragement to grieve their prior traumatic births to help remove the burden of their invisible pain.

  4. Gene Duplicability of Core Genes Is Highly Consistent across All Angiosperms[OPEN

    Science.gov (United States)

    Li, Zhen; Van de Peer, Yves; De Smet, Riet

    2016-01-01

    Gene duplication is an important mechanism for adding to genomic novelty. Hence, which genes undergo duplication and are preserved following duplication is an important question. It has been observed that gene duplicability, or the ability of genes to be retained following duplication, is a nonrandom process, with certain genes being more amenable to survive duplication events than others. Primarily, gene essentiality and the type of duplication (small-scale versus large-scale) have been shown in different species to influence the (long-term) survival of novel genes. However, an overarching view of “gene duplicability” is lacking, mainly due to the fact that previous studies usually focused on individual species and did not account for the influence of genomic context and the time of duplication. Here, we present a large-scale study in which we investigated duplicate retention for 9178 gene families shared between 37 flowering plant species, referred to as angiosperm core gene families. For most gene families, we observe a strikingly consistent pattern of gene duplicability across species, with gene families being either primarily single-copy or multicopy in all species. An intermediate class contains gene families that are often retained in duplicate for periods extending to tens of millions of years after whole-genome duplication, but ultimately appear to be largely restored to singleton status, suggesting that these genes may be dosage balance sensitive. The distinction between single-copy and multicopy gene families is reflected in their functional annotation, with single-copy genes being mainly involved in the maintenance of genome stability and organelle function and multicopy genes in signaling, transport, and metabolism. The intermediate class was overrepresented in regulatory genes, further suggesting that these represent putative dosage-balance-sensitive genes. PMID:26744215

  5. Dye-Incorporated Polynaphthalenediimide Acceptor for Additive-Free High-Performance All-Polymer Solar Cells.

    Science.gov (United States)

    Chen, Dong; Yao, Jia; Chen, Lie; Yin, Jingping; Lv, Ruizhi; Huang, Bin; Liu, Siqi; Zhang, Zhi-Guo; Yang, Chunhe; Chen, Yiwang; Li, Yongfang

    2018-04-16

    All-polymer solar cells (all-PSCs) can offer unique advantages for applications in flexible devices, and naphthalene diimide (NDI)-based polymer acceptors are the widely used polymer acceptors. However, their power conversion efficiency (PCE) still lags behind that of state-of-the-art polymer solar cells, due to low light absorption, suboptimal energy levels and the strong aggregation of the NDI-based polymer acceptor. Herein, a rhodanine-based dye molecule was introduced into the NDI-based polymer acceptor by simple random copolymerization and showed an improved light absorption coefficient, an up-shifted lowest unoccupied molecular orbital level and reduced crystallization. Consequently, additive-free all-PSCs demonstrated a high PCE of 8.13 %, which is one of the highest performance characteristics reported for all-PSCs to date. These results indicate that incorporating a dye into the n-type polymer gives insight into the precise design of high-performance polymer acceptors for all-PSCs. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. A Near-linear Time Approximation Algorithm for Angle-based Outlier Detection in High-dimensional Data

    DEFF Research Database (Denmark)

    Pham, Ninh Dang; Pagh, Rasmus

    2012-01-01

    projection-based technique that is able to estimate the angle-based outlier factor for all data points in time near-linear in the size of the data. Also, our approach is suitable to be performed in parallel environment to achieve a parallel speedup. We introduce a theoretical analysis of the quality...... neighbor are deteriorated in high-dimensional data. Following up on the work of Kriegel et al. (KDD '08), we investigate the use of angle-based outlier factor in mining high-dimensional outliers. While their algorithm runs in cubic time (with a quadratic time heuristic), we propose a novel random......Outlier mining in d-dimensional point sets is a fundamental and well studied data mining task due to its variety of applications. Most such applications arise in high-dimensional domains. A bottleneck of existing approaches is that implicit or explicit assessments on concepts of distance or nearest...

  7. The pathogenicity of genetic variants previously associated with left ventricular non-compaction

    DEFF Research Database (Denmark)

    Abbasi, Yeganeh; Jabbari, Javad; Jabbari, Reza

    2016-01-01

    BACKGROUND: Left ventricular non-compaction (LVNC) is a rare cardiomyopathy. Many genetic variants have been associated with LVNC. However, the number of the previous LVNC-associated variants that are common in the background population remains unknown. The aim of this study was to provide...... an updated list of previously reported LVNC-associated variants with biologic description and investigate the prevalence of LVNC variants in healthy general population to find false-positive LVNC-associated variants. METHODS AND RESULTS: The Human Gene Mutation Database and PubMed were systematically...... searched to identify all previously reported LVNC-associated variants. Thereafter, the Exome Sequencing Project (ESP) and the Exome Aggregation Consortium (ExAC), that both represent the background population, was searched for all variants. Four in silico prediction tools were assessed to determine...

  8. Previous ISD Program Review.

    Science.gov (United States)

    1981-03-01

    report. The detail required for such a review would be unwieldy and would comsume inordinate amounts of time. The result of the document review will...attempts have been made at writing specific behavioral objectives (SBOs). These, however, have proven to be inadequate in that they are not stated in... behavioral terms (e.g., "will understand," "will have a knowledge of," etc.). C. Development of CRO/CRTs? In nearly all cases, ISD teams are just

  9. Fluxes all of the time? A primer on the temporal representativeness of FLUXNET

    Science.gov (United States)

    Chu, Housen; Baldocchi, Dennis D.; John, Ranjeet; Wolf, Sebastian; Reichstein, Markus

    2017-02-01

    FLUXNET, the global network of eddy covariance flux towers, provides the largest synthesized data set of CO2, H2O, and energy fluxes. To achieve the ultimate goal of providing flux information "everywhere and all of the time," studies have attempted to address the representativeness issue, i.e., whether measurements taken in a set of given locations and measurement periods can be extrapolated to a space- and time-explicit extent (e.g., terrestrial globe, 1982-2013 climatological baseline). This study focuses on the temporal representativeness of FLUXNET and tests whether site-specific measurement periods are sufficient to capture the natural variability of climatological and biological conditions. FLUXNET is unevenly representative across sites in terms of the measurement lengths and potentials of extrapolation in time. Similarity of driver conditions among years generally enables the extrapolation of flux information beyond measurement periods. Yet such extrapolation potentials are further constrained by site-specific variability of driver conditions. Several driver variables such as air temperature, diurnal temperature range, potential evapotranspiration, and normalized difference vegetation index had detectable trends and/or breakpoints within the baseline period, and flux measurements generally covered similar and biased conditions in those drivers. About 38% and 60% of FLUXNET sites adequately sampled the mean conditions and interannual variability of all driver conditions, respectively. For long-record sites (≥15 years) the percentages increased to 59% and 69%, respectively. However, the justification of temporal representativeness should not rely solely on the lengths of measurements. Whenever possible, site-specific consideration (e.g., trend, breakpoint, and interannual variability in drivers) should be taken into account.

  10. Quantum electrodynamics at high temperature. 2

    International Nuclear Information System (INIS)

    Alvarez-Estrada, R.F.

    1988-01-01

    The photon sector of QED in d = 3 spatial dimensions is analyzed at high temperature thereby generalizing nontrivially a previous study for d = 1. The imaginary time formalism and an improved renormalized perturbation theory which incorporates second order Debye screening are used. General results are presented for the leading high temperature contributions to all renormalized connected photon Green's functions for fixed external momenta (much smaller than the temperature) to all orders in the improved perturbation theory. Those leading contributions are ultraviolet finite, infrared convergent and gauge invariant, and display an interesting form of dimensional reduction at high temperature. A new path integral representations is given for the high temperature partition function with an external photon source, which is shown to generate all leading high temperature Green's functions mentioned above, and, so, it displays neatly the kind of dimensional reduction which makes QED to become simpler at high temperature. This limiting partition function corresponds to an imaginary time dependent electron positron field interacting with an electromagnetic field at zero imaginary time, and it depends on the renormalized electron mass and electric charge, the second order contribution to the usual renormalization constant Z 3 and a new mass term, which is associated to the photon field with vanishing Lorentz index. The new mass term corresponds to a finite number of diagrams in the high temperature improved perturbation theory and carriers ultraviolet divergences which are compensated for by other contributions (so that the leading high temperature Green's functions referred to above are ultraviolet finite). The dominant high temperature contributions to the renormalized thermodynamic potential to all perturbative orders: i) are given in terms of the above leading high-temperature contributions to the photon Green's functions (except for a few diagrams of low order in the

  11. Risk perception and unrecognized type 2 diabetes in women with previous gestational diabetes mellitus.

    Science.gov (United States)

    Malcolm, Janine; Lawson, Margaret L; Gaboury, Isabelle; Keely, Erin

    2009-09-01

    Women with a history of gestational diabetes mellitus (GDM) have a high chance of developing type 2 diabetes mellitus (T2DM) following the index pregnancy, however, little is known of women's perception of this risk. The objectives were to (1) determine women's perception of risk of future development of T2DM following a GDM pregnancy and (2) describe the prevalence of undetected dysglycaemia in a Canadian population. The study was designed as a 9-11 year follow-up study of women previously enrolled in a randomized controlled trial of tight versus minimal intervention for GDM. Women's perception of future risk of diabetes was determined by questionnaire. Fasting lipid profile, height and weight were performed on all participants. Oral glucose tolerance tests were performed on all women without prior history of diabetes mellitus type 2 (DM2). The study was conducted at Ottawa Hospital General Campus and Children's Hospital of Eastern Ontario, in Ottawa, Canada. Eighty-nine of 299 (30%) of the original cohort were recruited. Eighty-eight women completed the questionnaire and 77 women without known diabetes underwent two hour glucose tolerance testing. Twenty-three (30%) felt their risk was no different than other women or did not know, 27 (35%) felt risk was increased a little and 27 (35%) felt risk was increased a lot. Only 52% (40/77) had normal glucose tolerance. Of all, 25/88 (28%) patients had diabetes (11 previously diagnosed and 14 diagnosed within the study). Of those newly diagnosed with DM2, four (29%) were diagnosed by fasting glucose, six (42%) by two hour glucose tolerance test (GTT) alone and four (29%) by both. Twenty-four of the women (27%) had impaired glucose tolerance (IGT). Of those with IGT, 12 (57%) had a fasting food glucose DM2, and all had a waist circumference >88 cm. In conclusion the perception of being at high risk for T2DM did not prevent women from having undetected T2DM. Many factors are likely to contribute to this, including the

  12. Impact of the "Planning to be Active" leisure time physical exercise program on rural high school students.

    Science.gov (United States)

    Hortz, Brian; Petosa, Rick

    2006-10-01

    The purpose of the study was to evaluate the effects of a Social Cognitive Theory-based intervention designed to increase the frequency of leisure time planned moderate and vigorous physical exercise among rural high school students attending physical education class. Students in treatment and comparison groups were exposed to an activity-based physical education curricula. The treatment group received eight behavioral skill-building lessons integrated into the existing curriculum. The Social Cognitive Theory-based educational treatment increased levels of moderate physical exercise occurring outside the classroom. This study demonstrated an impact on adolescent leisure time moderate physical exercise using classroom instruction. The intervention was most effective with students who were previously sedentary. The curricular approaches used to promote regular moderate exercise may be useful for sedentary adolescents.

  13. Effects of high energy photon emissions in laser generated ultra-relativistic plasmas: Real-time synchrotron simulations

    Energy Technology Data Exchange (ETDEWEB)

    Wallin, Erik [Department of Physics, Umeå University, SE–901 87 Umeå (Sweden); Department of Applied Physics, Chalmers University of Technology, SE–412 96 Göteborg (Sweden); Gonoskov, Arkady [Department of Applied Physics, Chalmers University of Technology, SE–412 96 Göteborg (Sweden); Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod 603950 (Russian Federation); University of Nizhny Novgorod, Nizhny Novgorod 603950 (Russian Federation); Marklund, Mattias [Department of Applied Physics, Chalmers University of Technology, SE–412 96 Göteborg (Sweden)

    2015-03-15

    We model the emission of high energy photons due to relativistic charged particle motion in intense laser-plasma interactions. This is done within a particle-in-cell code, for which high frequency radiation normally cannot be resolved due to finite time steps and grid size. A simple expression for the synchrotron radiation spectra is used together with a Monte-Carlo method for the emittance. We extend previous work by allowing for arbitrary fields, considering the particles to be in instantaneous circular motion due to an effective magnetic field. Furthermore, we implement noise reduction techniques and present validity estimates of the method. Finally, we perform a rigorous comparison to the mechanism of radiation reaction, and find the emitted energy to be in excellent agreement with the losses calculated using radiation reaction.

  14. A high-resolution, multi-stop, time-to-digital converter for nuclear time-of-flight measurements

    International Nuclear Information System (INIS)

    Spencer, D.F.; Cole, J.; Drigert, M.; Aryaeinejad, R.

    2006-01-01

    A high-resolution, multi-stop, time-to-digital converter (TDC) was designed and developed to precisely measure the times-of-flight (TOF) of incident neutrons responsible for induced fission and capture reactions on actinide targets. The minimum time resolution is ±1 ns. The TDC design was implemented into a single, dual-wide CAMAC module. The CAMAC bus is used for command and control as well as an alternative data output. A high-speed ECL interface, compatible with LeCroy FERA modules, was also provided for the principle data output path. An Actel high-speed field programmable gate array (FPGA) chip was incorporated with an external oscillator and an internal multiple clock phasing system. This device implemented the majority of the high-speed register functions, the state machine for the FERA interface, and the high-speed counting circuit used for the TDC conversion. An external microcontroller was used to monitor and control system-level changes. In this work we discuss the performance of this TDC module as well as its application

  15. New generation all-silica based optical elements for high power laser systems

    Science.gov (United States)

    Tolenis, T.; GrinevičiÅ«tÄ--, L.; Melninkaitis, A.; Selskis, A.; Buzelis, R.; MažulÄ--, L.; Drazdys, R.

    2017-08-01

    Laser resistance of optical elements is one of the major topics in photonics. Various routes have been taken to improve optical coatings, including, but not limited by, materials engineering and optimisation of electric field distribution in multilayers. During the decades of research, it was found, that high band-gap materials, such as silica, are highly resistant to laser light. Unfortunately, only the production of anti-reflection coatings of all-silica materials are presented to this day. A novel route will be presented in materials engineering, capable to manufacture high reflection optical elements using only SiO2 material and GLancing Angle Deposition (GLAD) method. The technique involves the deposition of columnar structure and tailoring the refractive index of silica material throughout the coating thickness. A numerous analysis indicate the superior properties of GLAD coatings when compared with standard methods for Bragg mirrors production. Several groups of optical components are presented including anti-reflection coatings and Bragg mirrors. Structural and optical characterisation of the method have been performed and compared with standard methods. All researches indicate the possibility of new generation coatings for high power laser systems.

  16. Analysis of previous screening examinations for patients with breast cancer

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Cha, Joo Hee; Han, Dae Hee; Choi, Young Ho; Hwang, Ki Tae; Ryu, Dae Sik; Kwak, Jin Ho; Moon, Woo Kyung

    2007-01-01

    We wanted to improve the quality of subsequent screening by reviewing the previous screening of breast cancer patients. Twenty-four breast cancer patients who underwent previous screening were enrolled. All 24 took mammograms and 15 patients also took sonograms. We reviewed the screening retrospectively according to the BI-RADS criteria and we categorized the results into false negative, true negative, true positive and occult cancers. We also categorized the causes of false negative cancers into misperception, misinterpretation and technical factors and then we analyzed the attributing factors. Review of the previous screening revealed 66.7% (16/24) false negative, 25.0% (6/24) true negative, and 8.3% (2/24) true positive cancers. False negative cancers were caused by the mammogram in 56.3% (9/16) and by the sonogram in 43.7% (7/16). For the false negative cases, all of misperception were related with mammograms and this was attributed to dense breast, a lesion located at the edge of glandular tissue or the image, and findings seen on one view only. Almost all misinterpretations were related with sonograms and attributed to loose application of the final assessment. To improve the quality of breast screening, it is essential to overcome the main causes of false negative examinations, including misperception and misinterpretation. We need systematic education and strict application of final assessment categories of BI-RADS. For effective communication among physicians, it is also necessary to properly educate them about BI-RADS

  17. Effects of Pelvic and Core Strength Training on High School Cross-Country Race Times.

    Science.gov (United States)

    Clark, Anne W; Goedeke, Maggie K; Cunningham, Saengchoy R; Rockwell, Derek E; Lehecka, Bryan J; Manske, Robert C; Smith, Barbara S

    2017-08-01

    Clark, AW, Goedeke, MK, Cunningham, SR, Rockwell, DE, Lehecka, BJ, Manske, RC, and Smith, BS. Effects of pelvic and core strength training on high school cross-country race times. J Strength Cond Res 31(8): 2289-2295, 2017-There is only limited research examining the effect of pelvic and core strength training on running performance. Pelvic and core muscle fatigue is believed to contribute to excess motion along frontal and transverse planes which decreases efficiency in normal sagittal plane running motions. The purpose of this study was to determine whether adding a 6-week pelvic and core strengthening program resulted in decreased race times in high school cross-country runners. Thirty-five high school cross-country runners (14-19 years old) from 2 high schools were randomly assigned to a strengthening group (experimental) or a nonstrengthening group (control). All participants completed 4 standardized isometric strength tests for hip abductors, adductors, extensors, and core musculature in a test-retest design. The experimental group performed a 6-week pelvic and core strengthening program along with their normal training. Participants in the control group performed their normal training without additional pelvic and core strengthening. Baseline, 3-week, and 6-week race times were collected using a repeated measures design. No significant interaction between experimental and control groups regarding decreasing race times and increasing pelvic and core musculature strength occurred over the 6-week study period. Both groups increased strength and decreased overall race times. Clinically significant findings reveal a 6-week pelvic and core stability strengthening program 3 times a week in addition to coach led team training may help decrease race times.

  18. Are All Oscillators Created Equal? In vitro Performance Characteristics of Eight High-Frequency Oscillatory Ventilators.

    Science.gov (United States)

    Tingay, David G; John, Jubal; Harcourt, Edward R; Black, Don; Dargaville, Peter A; Mills, John F; Davis, Peter G

    2015-01-01

    The mode of waveform generation and circuit characteristics differ between high-frequency oscillators. It is unknown if this influences performance. To describe the relationships between set and delivered pressure amplitude (x0394;P), and the interaction with frequency and endotracheal tube (ETT) diameter, in eight high-frequency oscillators. Oscillators were evaluated using a 70-ml test lung at 1.0 and 2.0 ml/cm H2O compliance, with mean airway pressures (PAW) of 10 and 20 cm H2O, frequencies of 5, 10 and 15 Hz, and an ETT diameter of 2.5 and 3.5 mm. At each permutation of PAW, frequency and ETT, the set x0394;P was sequentially increased from 15 to 50 cm H2O, or from 20 to 100% maximum amplitude (10% increments) depending on the oscillator design. The x0394;P at the ventilator (x0394;PVENT), airway opening (x0394;PAO) and within the test lung (x0394;PTRACH), and tidal volume (V(T)) at the airway opening were determined at each set x0394;P. In two oscillators the relationships between set and delivered x0394;P were non-linear, with a plateau in x0394;P thresholds noted at all frequencies (Dräger Babylog 8000) or ≥10 Hz (Dräger VN500). In all other devices there was a linear relationship between x0394;PVENT, x0394;PAO and x0394;PTRACH (all r2 >0.93), with differing attenuation of the pressure wave. Delivered V(T) at the different settings tested varied between devices, with some unable to deliver V(T) >3 ml at 15 Hz, and others generating V(T)>20 ml at 5 Hz and a 1:1 inspiratory-to-expiratory time ratio. Clinicians should be aware that modern high-frequency oscillators exhibit important differences in the delivered x0394;P and V(T). © 2015 S. Karger AG, Basel.

  19. Development of High Temperature Short Time Vertebrate-Blood Pasteurization Equipment for Tsetse Fly Diets

    Energy Technology Data Exchange (ETDEWEB)

    Moravek, I; Lach, J [Department of Manufacturing Systems, Slovak Technical University Namestie Slobody 17 812 31 Bratislava (Slovakia); Takac, P [Institute of Zoology, SAV, Bratislava (Slovakia)

    2012-07-15

    Tsetse flies feed only on vertebrate blood, but the collection and processing of blood is expensive, it must be stored at -20{sup o}C requiring costly storage rooms and reliable electricity, and it must be irradiated to reduce bacterial contamination. This is tolerable for small colonies, but as colony size increases to service large- scale programmes, the supply and processing of blood becomes critical. Blood is normally collected from cattle at slaughter. This process is necessarily not aseptic, and large-scale collection is only possible where the animals are suspended for bleeding. One alternative to blood decontamination is using the High Temperature Short time Pasteurization (HTST) method. The food processing industry uses pasteurization to reduce bacterial load in a wide range of products. Our previous results indicated that for the control of the blood pasteurization process, to reach satisfactory bacteriological purity and at the same time to prevent the blood from coagulating, it is important to study temperature and time and also some other parameters that could predict blood coagulation. Crucial for blood coagulation is to study blood viscosity. Classical heat exchangers are not suitable for blood pasteurization. In such equipment the blood coagulation depends on temperature and time. Besides the relatively low temperatures, blood is coagulating with cumulative time until total shutdown of blood flow. After a series of experiments we found a solution using microwave systems. To verify the microwave heating concept, we built an experimental workstation. First we verified the accuracy of the applicator design from the aspect of output adaptation to the power source. Also we installed measuring equipment. This system complies with the requirements of quick heating with sufficiently high heat accumulation. By utilizing standard components for the base of the microwave generator, it is possible to markedly reduce the final price of the equipment. (author)

  20. Left ventricular asynergy score as an indicator of previous myocardial infarction

    International Nuclear Information System (INIS)

    Backman, C.; Jacobsson, K.A.; Linderholm, H.; Osterman, G.

    1986-01-01

    Sixty-eight patients with coronary heart disease (CHD) i.e. a hisotry of angina of effort and/or previous 'possible infarction' were examined inter alia with ECG and cinecardioangiography. A system of scoring was designed which allowed a semiquantitative estimate of the left ventricular asynergy from cinecardioangiography - the left ventricular motion score (LVMS). The LVMS was associated with the presence of a previous myocardial infarction (MI), as indicated by the history and ECG findings. The ECG changes specific for a previous MI were associated with high LVMS values and unspecific or absent ECG changes with low LVMS values. Decision thresholds for ECG changes and asynergy in diagnosing a previous MI were evaluated by means of a ROC analysis. The accuracy of ECG in detecting a previous MI was slightly higher when asynergy indicated a 'true MI' than when autopsy result did so in a comparable group. Therefore the accuracy of asynergy (LVMS ≥ 1) in detecting a previous MI or myocardial fibrosis in patients with CHD should be at least comparable with that of autopsy (scar > 1 cm). (orig.)

  1. A method for generating high resolution satellite image time series

    Science.gov (United States)

    Guo, Tao

    2014-10-01

    There is an increasing demand for satellite remote sensing data with both high spatial and temporal resolution in many applications. But it still is a challenge to simultaneously improve spatial resolution and temporal frequency due to the technical limits of current satellite observation systems. To this end, much R&D efforts have been ongoing for years and lead to some successes roughly in two aspects, one includes super resolution, pan-sharpen etc. methods which can effectively enhance the spatial resolution and generate good visual effects, but hardly preserve spectral signatures and result in inadequate analytical value, on the other hand, time interpolation is a straight forward method to increase temporal frequency, however it increase little informative contents in fact. In this paper we presented a novel method to simulate high resolution time series data by combing low resolution time series data and a very small number of high resolution data only. Our method starts with a pair of high and low resolution data set, and then a spatial registration is done by introducing LDA model to map high and low resolution pixels correspondingly. Afterwards, temporal change information is captured through a comparison of low resolution time series data, and then projected onto the high resolution data plane and assigned to each high resolution pixel according to the predefined temporal change patterns of each type of ground objects. Finally the simulated high resolution data is generated. A preliminary experiment shows that our method can simulate a high resolution data with a reasonable accuracy. The contribution of our method is to enable timely monitoring of temporal changes through analysis of time sequence of low resolution images only, and usage of costly high resolution data can be reduces as much as possible, and it presents a highly effective way to build up an economically operational monitoring solution for agriculture, forest, land use investigation

  2. A real-time all-atom structural search engine for proteins.

    Science.gov (United States)

    Gonzalez, Gabriel; Hannigan, Brett; DeGrado, William F

    2014-07-01

    Protein designers use a wide variety of software tools for de novo design, yet their repertoire still lacks a fast and interactive all-atom search engine. To solve this, we have built the Suns program: a real-time, atomic search engine integrated into the PyMOL molecular visualization system. Users build atomic-level structural search queries within PyMOL and receive a stream of search results aligned to their query within a few seconds. This instant feedback cycle enables a new "designability"-inspired approach to protein design where the designer searches for and interactively incorporates native-like fragments from proven protein structures. We demonstrate the use of Suns to interactively build protein motifs, tertiary interactions, and to identify scaffolds compatible with hot-spot residues. The official web site and installer are located at http://www.degradolab.org/suns/ and the source code is hosted at https://github.com/godotgildor/Suns (PyMOL plugin, BSD license), https://github.com/Gabriel439/suns-cmd (command line client, BSD license), and https://github.com/Gabriel439/suns-search (search engine server, GPLv2 license).

  3. A discrete time-varying internal model-based approach for high precision tracking of a multi-axis servo gantry.

    Science.gov (United States)

    Zhang, Zhen; Yan, Peng; Jiang, Huan; Ye, Peiqing

    2014-09-01

    In this paper, we consider the discrete time-varying internal model-based control design for high precision tracking of complicated reference trajectories generated by time-varying systems. Based on a novel parallel time-varying internal model structure, asymptotic tracking conditions for the design of internal model units are developed, and a low order robust time-varying stabilizer is further synthesized. In a discrete time setting, the high precision tracking control architecture is deployed on a Voice Coil Motor (VCM) actuated servo gantry system, where numerical simulations and real time experimental results are provided, achieving the tracking errors around 3.5‰ for frequency-varying signals. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  4. RAMA casein zymography: Time-saving and highly sensitive casein zymography for MMP7 and trypsin.

    Science.gov (United States)

    Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kanaly, Robert A

    2016-11-01

    To detect metalloproteinase-7 (MMP7), zymography is conducted using a casein substrate and conventional CBB stain. It has disadvantages because it is time consuming and has low sensitivity. Previously, a sensitive method to detect MMP7 up to 30 pg was reported, however it required special substrates and complicated handlings. RAMA casein zymography described herein is rapid, sensitive, and reproducible. By applying high-sensitivity staining with low substrate conditions, the staining process is completed within 1 h and sensitivity was increased 100-fold. The method can detect 10 pg MMP7 by using commercially available casein without complicated handlings. Moreover, it increases detection sensitivity for trypsin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Mediastinal involvement in lymphangiomatosis: a previously unreported MRI sign

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Vikas; Shah, Sachit; Barnacle, Alex; McHugh, Kieran [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Sebire, Neil J. [Great Ormond Street Hospital for Children, Department of Histopathology, London (United Kingdom); Brock, Penelope [Great Ormond Street Hospital for Children, Department of Oncology, London (United Kingdom); Harper, John I. [Great Ormond Street Hospital for Children, Department of Dermatology, London (United Kingdom)

    2011-08-15

    Multifocal lymphangiomatosis is a rare systemic disorder affecting children. Due to its rarity and wide spectrum of clinical, histological and imaging features, establishing the diagnosis of multifocal lymphangiomatosis can be challenging. The purpose of this study was to describe a new imaging sign in this disorder: paraspinal soft tissue and signal abnormality at MRI. We retrospectively reviewed the imaging, clinical and histopathological findings in a cohort of eight children with thoracic involvement from this condition. Evidence of paraspinal chest disease was identified at MRI and CT in all eight of these children. The changes comprise heterogeneous intermediate-to-high signal parallel to the thoracic vertebrae on T2-weighted sequences at MRI, with abnormal paraspinal soft tissue at CT and plain radiography. Multifocal lymphangiomatosis is a rare disorder with a broad range of clinicopathological and imaging features. MRI allows complete evaluation of disease extent without the use of ionising radiation and has allowed us to describe a previously unreported imaging sign in this disorder, namely, heterogeneous hyperintense signal in abnormal paraspinal tissue on T2-weighted images. (orig.)

  6. Effects of Full-Time and Part-Time High-Ability Programs on Developments in Students' Achievement Emotions

    Science.gov (United States)

    Hornstra, Lisette; van der Veen, Ineke; Peetsma, Thea

    2017-01-01

    This study focused on effects of high-ability programs on students' achievement emotions, i.e. emotions that students experience that are associated with achievement activities. Participants were students in grade 4-6 of primary education: 218 students attended full-time high-ability programs, 245 attended part-time high-ability programs (i.e.…

  7. "Gratitude is with me all the time": how gratitude relates to wisdom.

    Science.gov (United States)

    König, Susanne; Glück, Judith

    2014-09-01

    This study investigated the relationship of gratitude to wisdom. Both constructs are conceptually related to self-reflectivity, but they differ in their emphasis on extrapersonal resources. Previous wisdom research has focused mainly on intrapersonal capacities. In Study 1, 47 wisdom nominees and 47 control participants were interviewed about their most difficult and best life event and filled out a questionnaire on sources of gratitude. Study 2 was a quantitative study (N = 443) of the relationship between a wisdom scale and scale measures and individual sources of gratitude. Significantly more wisdom nominees expressed feelings of gratitude spontaneously in their interview. Wisdom nominees reported gratitude for their life in general, religion, and partner more often than control participants. In Study 2, wisdom was related to all gratitude scales and to similar sources of gratitude as in Study 1. Both studies found gender differences in gratitude but not wisdom. Two important implications of these findings are that wisdom entails an appreciation of life and its experiences, especially the growth opportunities that may result from negative events, and that there may be substantial differences between male and female pathways to wisdom. © The Author 2013. Published by Oxford University Press on behalf of The Gerontological Society of America.

  8. Real-time control and data-acquisition system for high-energy neutral-beam injectors

    International Nuclear Information System (INIS)

    Glad, A.S.; Jacobson, V.

    1981-12-01

    The need for a real-time control system and a data acquisition, processing and archiving system operating in parallel on the same computer became a requirement on General Atomic's Doublet III fusion energy project with the addition of high energy neutral beam injectors. The data acquisition processing and archiving system is driven from external events and is sequenced through each experimental shot utilizing ModComp's intertask message service. This system processes, archives and displays on operator console CRTs all physics diagnostic data related to the neutral beam injectores such as temperature, beam alignment, etc. The real-time control system is data base driven and provides periodic monitoring and control of the numerous dynamic subsystems of the neutral beam injectors such as power supplies, timing, water cooling, etc

  9. The interplay between physical activity at work and during leisure time - risk of ischemic heart disease and all-cause mortality in middle-aged Caucasian men

    DEFF Research Database (Denmark)

    Holtermann, A.; Mortensen, O.S.; Burr, H.

    2009-01-01

    Objective our aim was to test the hypothesis that a high level of physical activity during leisure time increases the risk of ischemic heart disease (IHD) mortality among men with high physical work demands. Methods We carried out a 30-year follow-up of the Copenhagen Male Study of 5249 caueasian......, male workers aged 40-59 years; 274 men with overt cardiovascular disease were excluded from the follow-up. Results During the follow-up period, 591 men (11.9%) died from IIID. Cox analyses of men with low (N=1236), medium (N=2651), and high (N=858) physical work demands showed that those with high...... demands had a higher risk of IHD mortality compared to men with low demands [age-adjusted hazard ratio 1.51, 95% confidence interval (95% CI) 1 18-1.94]. In all three groups, men with a low level of physical activity during leisure time had a higher risk of IHD than men with a medium or high level Overall...

  10. The interplay between physical activity at work and during leisure time--risk of ischemic heart disease and all-cause mortality in middle-aged Caucasian men

    DEFF Research Database (Denmark)

    Holtermann, Andreas; Mortensen, Ole Steen; Burr, Hermann

    2009-01-01

    OBJECTIVE: Our aim was to test the hypothesis that a high level of physical activity during leisure time increases the risk of ischemic heart disease (IHD) mortality among men with high physical work demands. METHODS: We carried out a 30-year follow-up of the Copenhagen Male Study of 5249 caucasian......, male workers aged 40-59 years; 274 men with overt cardiovascular disease were excluded from the follow-up. RESULTS: During the follow-up period, 591 men (11.9%) died from IHD. Cox analyses of men with low (N=1236), medium (N=2651), and high (N=858) physical work demands showed that those with high...... demands had a higher risk of IHD mortality compared to men with low demands [age-adjusted hazard ratio 1.51, 95% confidence interval (95% CI) 1.18-1.94]. In all three groups, men with a low level of physical activity during leisure time had a higher risk of IHD than men with a medium or high level...

  11. A high-throughput, multi-channel photon-counting detector with picosecond timing

    Science.gov (United States)

    Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-06-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  12. A high-throughput, multi-channel photon-counting detector with picosecond timing

    International Nuclear Information System (INIS)

    Lapington, J.S.; Fraser, G.W.; Miller, G.M.; Ashton, T.J.R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.

  13. State all-driver distracted driving laws and high school students'  texting while driving behavior.

    Science.gov (United States)

    Qiao, Nan; Bell, Teresa Maria

    2016-01-01

    Texting while driving is highly prevalent among adolescents and young adults in the United States. Texting while driving can significantly increase the risk of road crashes and is associated with other risky driving behaviors. Most states have enacted distracted driving laws to prohibit texting while driving. This study examines effects of different all-driver distracted driving laws on texting while driving among high school students. High school student data were extracted from the 2013 National Youth Risk Behavior Survey. Distracted driving law information was collected from the National Conference of State Legislatures. The final sample included 6,168 high school students above the restricted driving age in their states and with access to a vehicle. Logistic regression was applied to estimate odds ratios of laws on texting while driving. All-driver text messaging bans with primary enforcement were associated with a significant reduction in odds of texting while driving among high school students (odds ratio = 0.703; 95% confidence interval, 0.513-0.964), whereas all-driver phone use bans with primary enforcement did not have a significant association with texting while driving (odds ratio = 0.846; 95% confidence interval, 0.501-1.429). The findings indicate that all-driver distracted driving laws that specifically target texting while driving as opposed to all types of phone use are effective in reducing the behavior among high school students.

  14. Real-time monitoring of high-gravity corn mash fermentation using in situ raman spectroscopy.

    Science.gov (United States)

    Gray, Steven R; Peretti, Steven W; Lamb, H Henry

    2013-06-01

    In situ Raman spectroscopy was employed for real-time monitoring of simultaneous saccharification and fermentation (SSF) of corn mash by an industrial strain of Saccharomyces cerevisiae. An accurate univariate calibration model for ethanol was developed based on the very strong 883 cm(-1) C-C stretching band. Multivariate partial least squares (PLS) calibration models for total starch, dextrins, maltotriose, maltose, glucose, and ethanol were developed using data from eight batch fermentations and validated using predictions for a separate batch. The starch, ethanol, and dextrins models showed significant prediction improvement when the calibration data were divided into separate high- and low-concentration sets. Collinearity between the ethanol and starch models was avoided by excluding regions containing strong ethanol peaks from the starch model and, conversely, excluding regions containing strong saccharide peaks from the ethanol model. The two-set calibration models for starch (R(2)  = 0.998, percent error = 2.5%) and ethanol (R(2)  = 0.999, percent error = 2.1%) provide more accurate predictions than any previously published spectroscopic models. Glucose, maltose, and maltotriose are modeled to accuracy comparable to previous work on less complex fermentation processes. Our results demonstrate that Raman spectroscopy is capable of real time in situ monitoring of a complex industrial biomass fermentation. To our knowledge, this is the first PLS-based chemometric modeling of corn mash fermentation under typical industrial conditions, and the first Raman-based monitoring of a fermentation process with glucose, oligosaccharides and polysaccharides present. Copyright © 2013 Wiley Periodicals, Inc.

  15. High-performance electronics for time-of-flight PET systems

    International Nuclear Information System (INIS)

    Choong, W-S; Peng, Q; Vu, C Q; Turko, B T; Moses, W W

    2013-01-01

    We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr 3 crystals respectively.

  16. Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography.

    Science.gov (United States)

    Lee, Youn-Joo; Kim, Bum-soo; Koo, Ja-Sung; Kim, Bom-Yi; Jang, Jinhee; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin

    2015-06-01

    Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P supra-aortic arterial stenosis, and could be more useful option than TOF-MRA. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions.

    Science.gov (United States)

    Xue, Hui; Kellman, Peter; Larocca, Gina; Arai, Andrew E; Hansen, Michael S

    2013-11-14

    Cine cardiovascular magnetic resonance (CMR) is challenging in patients who cannot perform repeated breath holds. Real-time, free-breathing acquisition is an alternative, but image quality is typically inferior. There is a clinical need for techniques that achieve similar image quality to the segmented cine using a free breathing acquisition. Previously, high quality retrospectively gated cine images have been reconstructed from real-time acquisitions using parallel imaging and motion correction. These methods had limited clinical applicability due to lengthy acquisitions and volumetric measurements obtained with such methods have not previously been evaluated systematically. This study introduces a new retrospective reconstruction scheme for real-time cine imaging which aims to shorten the required acquisition. A real-time acquisition of 16-20s per acquired slice was inputted into a retrospective cine reconstruction algorithm, which employed non-rigid registration to remove respiratory motion and SPIRiT non-linear reconstruction with temporal regularization to fill in missing data. The algorithm was used to reconstruct cine loops with high spatial (1.3-1.8 × 1.8-2.1 mm²) and temporal resolution (retrospectively gated, 30 cardiac phases, temporal resolution 34.3 ± 9.1 ms). Validation was performed in 15 healthy volunteers using two different acquisition resolutions (256 × 144/192 × 128 matrix sizes). For each subject, 9 to 12 short axis and 3 long axis slices were imaged with both segmented and real-time acquisitions. The retrospectively reconstructed real-time cine images were compared to a traditional segmented breath-held acquisition in terms of image quality scores. Image quality scoring was performed by two experts using a scale between 1 and 5 (poor to good). For every subject, LAX and three SAX slices were selected and reviewed in the random order. The reviewers were blinded to the reconstruction approach and acquisition protocols and

  18. Triglycerides as an early pathophysiological marker of endothelial dysfunction in nondiabetic women with a previous history of gestational diabetes.

    Science.gov (United States)

    Sokup, Alina; Góralczyk, Barbara; Góralczyk, Krzysztof; Rość, Danuta

    2012-02-01

    To investigate whether baseline triglyceride levels are associated with early glucose dysregulation and/or cardiovascular risk in women with a previous history of gestational diabetes. Prospective postpregnancy cohort study. Polish university hospitals. Participants included 125 women with previous gestational diabetes and 40 women with normal glucose regulation during pregnancy. All women were studied 2-24 months (mean 12 ± 10 months) after the index pregnancy. Women with previous gestational diabetes were divided into tertiles in accordance with baseline triglyceride levels. We assessed glucose regulation (oral glucose tolerance test), insulin resistance (homeostasis model assessment), markers of endothelial dysfunction (soluble: intercellular adhesion molecule-1, vascular cell adhesion molecule-1, E-selectin, tissue plasminogen activator antigen, von Willebrand factor antigen), fibrinolysis (plasminogen activator inhibitor antigen), inflammation (high-sensitivity C-reactive protein) and lipid levels. Women with previous gestational diabetes (78% normal glucose regulation, 22% impaired glucose tolerance) had a high cardiometabolic risk profile compared with control women (100% normal glucose regulation). Baseline triglycerides >0.83 mmol/l were associated with a higher prevalence of impaired glucose tolerance, higher high-sensitivity C-reactive protein and triglyceride/high-density lipoprotein-cholesterol ratio. Triglycerides >1.22 mmol/l were associated with higher body fat indexes, higher insulin resistance, higher levels of endothelial dysfunction biomarkers, higher plasminogen activator inhibitor antigen and dyslipidemia. Only E-selectin was independently associated with triglyceride levels. Baseline triglyceride levels are a cardiovascular risk marker as well as a pathophysiological parameter independently associated with endothelial dysfunction in nondiabetic women with previous gestational diabetes at 2-24 months after an index pregnancy. Normalization of

  19. First Insight into a Nationwide Genotypic Diversity of Mycobacterium tuberculosis among Previously Treated Pulmonary Tuberculosis Cases in Benin, West Africa.

    Science.gov (United States)

    Affolabi, Dissou; Sanoussi, N'Dira; Codo, Sergio; Sogbo, Fréderic; Wachinou, Prudence; Massou, Faridath; Kehinde, Aderemi; Anagonou, Séverin

    2017-01-01

    Molecular studies on tuberculosis (TB) are rare in low-resource countries like Benin, where data on molecular study on previously treated TB cases is unavailable. From January to December 2014, all smear- and culture-positive previously treated pulmonary TB patients from all TB clinics were systematically recruited. Drug susceptibility testing and spoligotyping were performed on all isolates. Of the 100 patients recruited, 71 (71.0%) were relapse cases and 24 (24.0%) were failure cases, while 5 (5.0%) were default cases. Resistance rate to any first-line drug was 40.0%, while 12.0% of strains were multidrug-resistant (MDR) and no strain was extensively drug-resistant (XDR). A total of 40 distinct spoligotypes were found to be corresponding to a genotypic diversity of 40.0%. ST61 was the most predominant spoligotype with prevalence of 33.0%. In all, 31 single spoligotypes and nine clusters were observed with 2 to 33 strains per cluster giving a clustering rate of 69.0%. Euro-American (Lineage 4) was the most prevalent lineage (74.0%) and Lineage 2 was associated with resistance to streptomycin. This first insight into genetic diversity of previously treated pulmonary TB patients in Benin showed a relatively high genetic diversity of Mycobacterium tuberculosis .

  20. First Insight into a Nationwide Genotypic Diversity of Mycobacterium tuberculosis among Previously Treated Pulmonary Tuberculosis Cases in Benin, West Africa

    Directory of Open Access Journals (Sweden)

    Dissou Affolabi

    2017-01-01

    Full Text Available Background. Molecular studies on tuberculosis (TB are rare in low-resource countries like Benin, where data on molecular study on previously treated TB cases is unavailable. Materials and Methods. From January to December 2014, all smear- and culture-positive previously treated pulmonary TB patients from all TB clinics were systematically recruited. Drug susceptibility testing and spoligotyping were performed on all isolates. Results. Of the 100 patients recruited, 71 (71.0% were relapse cases and 24 (24.0% were failure cases, while 5 (5.0% were default cases. Resistance rate to any first-line drug was 40.0%, while 12.0% of strains were multidrug-resistant (MDR and no strain was extensively drug-resistant (XDR. A total of 40 distinct spoligotypes were found to be corresponding to a genotypic diversity of 40.0%. ST61 was the most predominant spoligotype with prevalence of 33.0%. In all, 31 single spoligotypes and nine clusters were observed with 2 to 33 strains per cluster giving a clustering rate of 69.0%. Euro-American (Lineage 4 was the most prevalent lineage (74.0% and Lineage 2 was associated with resistance to streptomycin. Conclusion. This first insight into genetic diversity of previously treated pulmonary TB patients in Benin showed a relatively high genetic diversity of Mycobacterium tuberculosis.

  1. High performance all polymer solar cells fabricated via non-halogenated solvents (Presentation Recording)

    Science.gov (United States)

    Zhou, Yan; Bao, Zhenan

    2015-10-01

    The performance of organic solar cells consisting of a donor/acceptor bulk heterojunction (BHJ) has rapidly improved over the past few years.1. Major efforts have been focused on developing a variety of donor materials to gain access to different regions of the solar spectrum as well as to improve carrier transport properties.2 On the other hand, the most utilized acceptors are still restricted to the fullerene family, which includes PC61BM, PC71BM and ICBA.2b, 3 All-polymer solar cells, consisting of polymers for both the donor and acceptor, gained significantly increased interests recently, because of their ease of solution processing, potentially low cost, versatility in molecular design, and their potential for good chemical and morphological stability due to entanglement of polymers. Unlike small molecular fullerene acceptors, polymer acceptors can benefit from the high mobility of intra-chain charge transport and exciton generation by both donor and acceptor. Despite extensive efforts on all-polymer solar cells in the past decade, the fundamental understanding of all-polymer solar cells is still in its inceptive stage regarding both the materials chemistry and structure physics.4 Thus, rational design rules must be utilized to enable fundamental materials understanding of the all polymer solar cells. We report high performance all-polymer solar cells employing polymeric donors based on isoindigo and acceptor based on perylenedicarboximide. The phase separation domain length scale correlates well with the JSC and is found to be highly sensitive to the aromatic co-monomer structures used in the crystalline donor polymers. With the PS polymer side chain engineering, the phase separation domain length scale decreased by more than 45%. The PCE and JSC of the devices increased accordingly by more than 20%. A JSC as high as 10.0 mA cm-2 is obtained with the donor-acceptor pair despite of a low LUMO-LUMO energy offset of less than 0.1 eV. All the factors such as

  2. Sum of All-Pairs Shortest Path Distances in a Planar Graph in Subquadratic Time

    DEFF Research Database (Denmark)

    Wulff-Nilsen, Christian

    2008-01-01

    We consider the problem of computing the Wiener index of a graph, defined as the sum of distances between all pairs of its vertices. It is an open problem whether the Wiener index of a planar graph can be found in subquadratic time. We solve this problem by presenting an algorithm with O(n^2*log...

  3. Impact of Socioeconomic Status on Timing of Relapse and Overall Survival for Children Treated on Dana-Farber Cancer Institute ALL Consortium Protocols (2000-2010).

    Science.gov (United States)

    Bona, Kira; Blonquist, Traci M; Neuberg, Donna S; Silverman, Lewis B; Wolfe, Joanne

    2016-06-01

    Population-based evidence suggests that lower socioeconomic status (SES) negatively impacts the overall survival (OS) of children with leukemia; however, the relationships between SES and treatment-related mortality, relapse, and timing of relapse remain unclear. We examined OS, event-free survival (EFS) and cumulative incidence (CI) and timing of relapse by community-level poverty for 575 children aged 1-18 years with newly diagnosed acute lymphoblastic leukemia (ALL) treated on consecutive phase III multicenter Dana-Farber Cancer Institute ALL Consortium Protocols between 2000 and 2010. Children were categorized into high- and low-poverty areas for the analysis using aggregate U.S. Census data linked to zip code. Children living in high-poverty areas experienced a 5-year OS of 85% as compared with 92% for those in low-poverty areas (P = 0.02); poverty remained marginally significant (P = 0.07) after adjustment for immunophenotype, age, and white blood cell count. There were no differences detected in EFS or CI relapse by poverty area. However, 92% of the relapses observed in children from high-poverty areas occurred <36 months from complete remission, compared to 48% of those in children from low-poverty areas (P = 0.008). U.S. children with ALL living in high-poverty areas have a higher risk of early relapse when compared with those living in low-poverty areas despite uniform treatment. This may in part explain decreased OS observed in these children. This finding highlights disparities in childhood cancer outcomes by SES despite uniform treatment. Further investigations of the mechanistic pathways underlying this finding are needed. © 2016 Wiley Periodicals, Inc.

  4. Revisiting the Link Between Depression Symptoms and High School Dropout: Timing of Exposure Matters.

    Science.gov (United States)

    Dupéré, Véronique; Dion, Eric; Nault-Brière, Frédéric; Archambault, Isabelle; Leventhal, Tama; Lesage, Alain

    2018-02-01

    Recent reviews concluded that past depression symptoms are not independently associated with high school dropout, a conclusion that could induce schools with high dropout rates and limited resources to consider depression screening, prevention, and treatment as low-priority. Even if past symptoms are not associated with dropout, however, it is possible that recent symptoms are. The goal of this study was to examine this hypothesis. In 12 disadvantaged high schools in Montreal (Canada), all students at least 14 years of age were first screened between 2012 and 2015 (N screened  = 6,773). Students who dropped out of school afterward (according to school records) were then invited for interviews about their mental health in the past year. Also interviewed were matched controls with similar risk profiles but who remained in school, along with average not at-risk schoolmates (N interviewed  = 545). Interviews were conducted by trained graduate students. Almost one dropout out of four had clinically significant depressive symptoms in the 3 months before leaving school. Adolescents with recent symptoms had an odd of dropping out more than twice as high as their peers without such symptoms (adjusted odds ratio = 2.17; 95% confidence interval = 1.14-4.12). In line with previous findings, adolescents who had recovered from earlier symptoms were not particularly at risk. These findings suggest that to improve disadvantaged youths' educational outcomes, investments in comprehensive mental health services are needed in schools struggling with high dropout rates, the very places where adolescents with unmet mental health needs tend to concentrate. Copyright © 2017 The Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  5. Influence of previous administration of trans-phenylcyclopropylamine on radioprotective and hypothermic effects of serotonin

    International Nuclear Information System (INIS)

    Misustova, J.; Hosek, B.; Novak, L.; Kautska, J.

    1978-01-01

    The influence of a previous administration of trans-phenylcyclopropylamine (t-PCPA) on radioprotective and hypothermic effects of serotonin was studied in male mice of the H strain, which were given t-PCPA in the dose of 4 mg/kg intraperitoneally 2 or 7 hours before application of serotonin (40 mg/kg, i.p.). The time course of protection was studied for exposures to 800 and 900 R. The results have shown that a previous administration of t-PCPA does not alter the short-time protective effect of serotonin, but that it significantly prolongs the time course of protection. The administration of t-PCPA also affects the starting speed and the duration of the serotonin-induced hypothermic reaction. The established correlation between prolongation of the radioprotective and hypothermic effects of serotonin induced by previous application of t-PCPA supplements the results with the existence of mutual relationship between changes of the energetic exchange and radioresistance of the organism. (author)

  6. Impact of diurnal temperature range on mortality in a high plateau area in southwest China: A time series analysis.

    Science.gov (United States)

    Ding, Zan; Guo, Pi; Xie, Fang; Chu, Huifang; Li, Kun; Pu, Jingbo; Pang, Shaojie; Dong, Hongli; Liu, Yahui; Pi, Fuhua; Zhang, Qingying

    2015-09-01

    Diurnal temperature range (DTR) is an important meteorological indicator that reflects weather stability and is associated with global climate change and urbanization. Previous studies have explored the effect of DTR on human health in coastal cities with small daily temperature variations, but we have little evidence for high plateau regions where large DTRs usually occur. Using daily mortality data (2007-2013), we conducted a time-series analysis to assess the effect of DTR on daily mortality in Yuxi, a high plateau city in southwest China. Poisson regression with distributed lag non-linear model was used to estimate DTR effects on daily mortality, controlling for daily mean temperature, relative humidity, sunshine duration, wind speed, atmospheric pressure, day of the week, and seasonal and long-term trends. The cumulative effects of DTR were J-shaped curves for non-accidental, cardiorespiratory and cardiovascular mortality, with a U-shaped curve for respiratory mortality. Risk assessments showed strong monotonic increases in mortality starting at a DTR of approximately 16 °C. The relative risk of non-accidental morality with extreme high DTR at lag 0 and 0-21 days was 1.03 (95% confidence interval: 0.95-1.11) and 1.33 (0.94-1.89), respectively. The risk of mortality with extreme high DTR was greater for males and age <75 years than females and age ≥75 years. The effect of DTR on mortality was non-linear, with high DTR associated with increased mortality. A DTR of 16 °C may be a cut-off point for mortality prognosis and has implications for developing intervention strategies to address high DTR exposure. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Ferroelectric BiFeO3as an Oxide Dye in Highly Tunable Mesoporous All-Oxide Photovoltaic Heterojunctions

    KAUST Repository

    Wang, Lingfei

    2016-10-12

    As potential photovoltaic materials, transition-metal oxides such as BiFeO3 (BFO) are capable of absorbing a substantial portion of solar light and incorporating ferroic orders into solar cells with enhanced performance. But the photovoltaic application of BFO has been hindered by low energy-conversion efficiency due to poor carrier transport and collection. In this work, a new approach of utilizing BFO as a light-absorbing sensitizer is developed to interface with charge-transporting TiO2 nanoparticles. This mesoporous all-oxide architecture, similar to that of dye-sensitized solar cells, can effectively facilitate the extraction of photocarriers. Under the standard AM1.5 (100 mW cm−2) irradiation, the optimized cell shows an open-circuit voltage of 0.67 V, which can be enhanced to 1.0 V by tailoring the bias history. A fill factor of 55% is achieved, which is much higher than those in previous reports on BFO-based photovoltaic devices. The results provide here a new viable approach toward developing highly tunable and stable photovoltaic devices based on ferroelectric transition-metal oxides.

  8. High-visibility time-bin entanglement for testing chained Bell inequalities

    Science.gov (United States)

    Tomasin, Marco; Mantoan, Elia; Jogenfors, Jonathan; Vallone, Giuseppe; Larsson, Jan-Åke; Villoresi, Paolo

    2017-03-01

    The violation of Bell's inequality requires a well-designed experiment to validate the result. In experiments using energy-time and time-bin entanglement, initially proposed by Franson in 1989, there is an intrinsic loophole due to the high postselection. To obtain a violation in this type of experiment, a chained Bell inequality must be used. However, the local realism bound requires a high visibility in excess of 94.63% in the time-bin entangled state. In this work, we show how such a high visibility can be reached in order to violate a chained Bell inequality with six, eight, and ten terms.

  9. Tunable All Reflective Spatial Heterodyne Spectroscopy, A Technique For High Resolving Power Observation OI Defused Emission Line Sources

    Science.gov (United States)

    Hosseini, Seyedeh Sona

    high (R >105) spectral resolution and large etendue in a small package that is compatible with space mission requirements that have not been met with any other SHS technologies to date. One limitation of current SHS designs is the lack of a broadband capability. To address this gap we are developing a form of the reflective SHS that is tunable over a wide range of wavelength (TSHS). In this work, we describe the primary TSHS concept in a mathematical approach, describe the variations under development, and discuss their scientific potential for the exploration of faint extended targets. An in-development laboratory prototype of a second generation TSHS in which we address several technical limitations noted in earlier studies is shown. This document contains three chapters. Chapter 1, is an overview of the scientific need for a new instrument that we are introducing here and it is an summery of previous papers. Chapter 2 contains new work developing the mathematical frame work for the all reflective SHS. The results presented in this chapter have not been reported in any related literature before and will be presented in an upcoming conference paper. Chapter 3 contains a laboratory report for construction of a tunable all reflective SHS.

  10. Study of functional-performance deficits in athletes with previous ankle sprains

    Directory of Open Access Journals (Sweden)

    hamid Babaee

    2008-04-01

    Full Text Available Abstract Background: Despite the importance of functional-performance deficits in athletes with history of ankle sprain few, studies have been carried out in this area. The aim of this research was to study relationship between previous ankle sprains and functional-performance deficits in athletes. Materials and methods: The subjects were 40 professional athletes selected through random sampling among volunteer participants in soccer, basketball, volleyball and handball teams of Lorestan province. The subjects were divided into 2 groups: Injured group (athletes with previous ankle sprains and healthy group (athletes without previous ankle sprains. In this descriptive study we used Functional-performance tests (figure 8 hop test and side hop test to determine ankle deficits and limitations. They participated in figure 8 hop test including hopping in 8 shape course with the length of 5 meters and side hop test including 10 side hop repetitions in course with the length of 30 centimeters. Time were recorded via stopwatch. Results: After data gathering and assessing information distributions, Pearson correlation was used to assess relationships, and independent T test to assess differences between variables. Finally the results showed that there is a significant relationship between previous ankle sprains and functional-performance deficits in the athletes. Conclusion: The athletes who had previous ankle sprains indicated functional-performance deficits more than healthy athletes in completion of mentioned functional-performance tests. The functional-performance tests (figure 8 hop test and side hop test are sensitive and suitable to assess and detect functional-performance deficits in athletes. Therefore we can use the figure 8 hop and side hop tests for goals such as prevention, assessment and rehabilitation of ankle sprains without spending too much money and time.

  11. One-step electrochemically expanded graphite foil for flexible all-solid supercapacitor with high rate performance

    International Nuclear Information System (INIS)

    Li, Han-Yu; Yu, Yao; Liu, Lang; Liu, Lin; Wu, Yue

    2017-01-01

    Flexible solid-state supercapacitors (SSCs) as a candidate for energy storage source, have been attracting intensive attention. Graphene-based materials for SSCs have been widely studied. However, most reported preparation methods for graphene-based materials are energy-consuming, time-consuming and environmentally hazardous, what’s more, the assembling of SSCs need additives, such as current collectors, flexible substrates. So, it is necessary to develop simpler and greener attempts to achieve high-performance, cost-effective, substrates/additives-free and flexible electrodes for SSC devices. Herein, we reported a green and facile one-step process of electrochemical oxidation and expansion in salt solution to activate graphite foil (GF) for fabricating expanded graphite foil (EGF). The EGF electrode with unique structure and high conductivity showed high supercapacitor performance of 65 mF cm −2 , remarkable rate-capability maintaining at a level of 80% even at a current density of 20 mA cm −2 and excellent cycling stability with ∼95% capacitance remaining after 10000 cycles at a current density of 20 mA cm −2 . Moreover, a symmetric flexible all-solid supercapacitor (SSC) device was integrated using EGFs without any current collectors and additives. The flexible EGF-based device showed a high capacitance capacity of 30.5 mF cm −2 , excellent rate performance and good cycle stability which make it holds promise for applications in flexible, portable and wearable electronic devices.

  12. Highly compressible three-dimensional graphene hydrogel for foldable all-solid-state supercapacitor

    Science.gov (United States)

    Liu, Xianbin; Zou, Shuai; Liu, Kaixi; Lv, Chao; Wu, Ziping; Yin, Yanhong; Liang, Tongxiang; Xie, Zailai

    2018-04-01

    The fabrication of three-dimensional (3D) graphene-based macroscopic materials with superior mechanical and electrical properties for flexible energy storage devices is still extremely challenging. Here, we report a novel 3D graphene hydrogel decorated by the biomass phytic acid (PAGH) with developed porosity and strengthen mechanical property via hydrothermal and freeze-drying methods. The phytic acid molecules are intercalated into the graphene sheets, enabling robust network structure. This induces the formation of materials with larger specific surface area, lower density and enhanced compressive strength compared with pure GH. When directly employed as an electrode, the PAGH exhibits a high specific capacitance of 248.8 F g-1 at 1 A g-1 and excellent rate performance of 67.9% as current density increasing to 20 A g-1. Furthermore, the all-solid-state supercapacitor based PAGH can deliver outstanding cycle life (86.2% after cycling 10,000 times), glorious energy density (26.5 Wh kg-1) and power density (5135.1 W kg-1). The prepared device shows stable electrochemical behaviors at random bending angles. Therefore, the present work will open a new avenue to design and fabricate new flexible and portable graphene-based electrodes for future applications in energy storage devices.

  13. hctsa: A Computational Framework for Automated Time-Series Phenotyping Using Massive Feature Extraction.

    Science.gov (United States)

    Fulcher, Ben D; Jones, Nick S

    2017-11-22

    Phenotype measurements frequently take the form of time series, but we currently lack a systematic method for relating these complex data streams to scientifically meaningful outcomes, such as relating the movement dynamics of organisms to their genotype or measurements of brain dynamics of a patient to their disease diagnosis. Previous work addressed this problem by comparing implementations of thousands of diverse scientific time-series analysis methods in an approach termed highly comparative time-series analysis. Here, we introduce hctsa, a software tool for applying this methodological approach to data. hctsa includes an architecture for computing over 7,700 time-series features and a suite of analysis and visualization algorithms to automatically select useful and interpretable time-series features for a given application. Using exemplar applications to high-throughput phenotyping experiments, we show how hctsa allows researchers to leverage decades of time-series research to quantify and understand informative structure in time-series data. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Sub-micrometer-thick all-solid-state supercapacitors with high power and energy densities

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Fanhui [Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, and School of Chemistry and Chemical Engineering, Shandong University, Jinan 250061 (China); Ding, Yi [Key Laboratory for Liquid-Solid Structural Evolution and Processing of Materials, Ministry of Education, and School of Chemistry and Chemical Engineering, Shandong University, Jinan 250061 (China); Shandong Applied Research Center for Gold Technology (Au-SDARC), Yantai 264005 (China)

    2011-09-15

    A sub-micrometer-thick, flexible, all-solid-state supercapacitor is fabricated. Through simultaneous realization of high dispersity of pseudocapacitance materials and quick electrode response, the hybrid nanostructures show enhanced volumetric capacitance and excellent stability, as well as very high power and energy densities. This suggests their potential as next-generation, high-performance energy conversion and storage devices for wearable electronics. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Decentralized adaptive neural control for high-order interconnected stochastic nonlinear time-delay systems with unknown system dynamics.

    Science.gov (United States)

    Si, Wenjie; Dong, Xunde; Yang, Feifei

    2018-03-01

    This paper is concerned with the problem of decentralized adaptive backstepping state-feedback control for uncertain high-order large-scale stochastic nonlinear time-delay systems. For the control design of high-order large-scale nonlinear systems, only one adaptive parameter is constructed to overcome the over-parameterization, and neural networks are employed to cope with the difficulties raised by completely unknown system dynamics and stochastic disturbances. And then, the appropriate Lyapunov-Krasovskii functional and the property of hyperbolic tangent functions are used to deal with the unknown unmatched time-delay interactions of high-order large-scale systems for the first time. At last, on the basis of Lyapunov stability theory, the decentralized adaptive neural controller was developed, and it decreases the number of learning parameters. The actual controller can be designed so as to ensure that all the signals in the closed-loop system are semi-globally uniformly ultimately bounded (SGUUB) and the tracking error converges in the small neighborhood of zero. The simulation example is used to further show the validity of the design method. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Design of high-order all-optical temporal differentiators based on multiple-phase-shifted fiber Bragg gratings.

    Science.gov (United States)

    Kulishov, Mykola; Azaña, José

    2007-05-14

    A simple and general approach for designing practical all-optical (all-fiber) arbitrary-order time differentiators is introduced here for the first time. Specifically, we demonstrate that the Nth time derivative of an input optical waveform can be obtained by reflection of this waveform in a single uniform fiber Bragg grating (FBG) incorporating N &pi-phase shifts properly located along its grating profile. The general design procedure of an arbitrary-order optical time differentiator based on a multiple-phase-shifted FBG is described and numerically demonstrated for up to fourth-order time differentiation. Our simulations show that the proposed approach can provide optical operation bandwidths in the tens-of-GHz regime using readily feasible FBG structures.

  17. Nuclear Physics in High School: what are the previous knowledge?

    Science.gov (United States)

    Pombo, F. de O.

    2017-11-01

    Nuclear physics is a branch of physics that about a century occupies an important space in the theoretical, experimental and scientific fields. Currently, its relevance in application is concentrated in several areas such as energy production, diagnostic processes and medical treatment and nuclear bombs, high destructive power. Whereas, according to legal regulations, the teaching of physics must make the student competent in the understanding of the world and assuming the perspective of Paulo Freire (2011) that education is not done on the subject, but together with him, in dialogue with his point of departure, his prior knowledge, we established the general objective of raising students prior knowledge of the third year of high School at Nair Ferreira Neves school, in São Sebastião-SP, about nuclear physics. We concluded that the school has not fulfilled its role in relation to nuclear physics, because students have information from other means of information and these knowledge are stereotyped and mistaken, damaging the world's reading and exercising full citizenship.

  18. Recovery from the most profound mass extinction of all time.

    Science.gov (United States)

    Sahney, Sarda; Benton, Michael J

    2008-04-07

    The end-Permian mass extinction, 251 million years (Myr) ago, was the most devastating ecological event of all time, and it was exacerbated by two earlier events at the beginning and end of the Guadalupian, 270 and 260 Myr ago. Ecosystems were destroyed worldwide, communities were restructured and organisms were left struggling to recover. Disaster taxa, such as Lystrosaurus, insinuated themselves into almost every corner of the sparsely populated landscape in the earliest Triassic, and a quick taxonomic recovery apparently occurred on a global scale. However, close study of ecosystem evolution shows that true ecological recovery was slower. After the end-Guadalupian event, faunas began rebuilding complex trophic structures and refilling guilds, but were hit again by the end-Permian event. Taxonomic diversity at the alpha (community) level did not recover to pre-extinction levels; it reached only a low plateau after each pulse and continued low into the Late Triassic. Our data showed that though there was an initial rise in cosmopolitanism after the extinction pulses, large drops subsequently occurred and, counter-intuitively, a surprisingly low level of cosmopolitanism was sustained through the Early and Middle Triassic.

  19. The 1985 central chile earthquake: a repeat of previous great earthquakes in the region?

    Science.gov (United States)

    Comte, D; Eisenberg, A; Lorca, E; Pardo, M; Ponce, L; Saragoni, R; Singh, S K; Suárez, G

    1986-07-25

    A great earthquake (surface-wave magnitude, 7.8) occurred along the coast of central Chile on 3 March 1985, causing heavy damage to coastal towns. Intense foreshock activity near the epicenter of the main shock occurred for 11 days before the earthquake. The aftershocks of the 1985 earthquake define a rupture area of 170 by 110 square kilometers. The earthquake was forecast on the basis of the nearly constant repeat time (83 +/- 9 years) of great earthquakes in this region. An analysis of previous earthquakes suggests that the rupture lengths of great shocks in the region vary by a factor of about 3. The nearly constant repeat time and variable rupture lengths cannot be reconciled with time- or slip-predictable models of earthquake recurrence. The great earthquakes in the region seem to involve a variable rupture mode and yet, for unknown reasons, remain periodic. Historical data suggest that the region south of the 1985 rupture zone should now be considered a gap of high seismic potential that may rupture in a great earthquake in the next few tens of years.

  20. High-Temperature-Short-Time Annealing Process for High-Performance Large-Area Perovskite Solar Cells.

    Science.gov (United States)

    Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk

    2017-06-27

    Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.

  1. High-resolution seismic wave propagation using local time stepping

    KAUST Repository

    Peter, Daniel; Rietmann, Max; Galvez, Percy; Ampuero, Jean Paul

    2017-01-01

    High-resolution seismic wave simulations often require local refinements in numerical meshes to accurately capture e.g. steep topography or complex fault geometry. Together with explicit time schemes, this dramatically reduces the global time step

  2. A high-energy, high-flux source of gamma-rays from all-optical non-linear Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Corvan, D.J., E-mail: dcorvan01@qub.ac.uk; Zepf, M.; Sarri, G.

    2016-09-01

    γ-Ray sources are among the most fundamental experimental tools currently available to modern physics. As well as the obvious benefits to fundamental research, an ultra-bright source of γ-rays could form the foundation of scanning of shipping containers for special nuclear materials and provide the bases for new types of cancer therapy. However, for these applications to prove viable, γ-ray sources must become compact and relatively cheap to manufacture. In recent years, advances in laser technology have formed the cornerstone of optical sources of high energy electrons which already have been used to generate synchrotron radiation on a compact scale. Exploiting the scattering induced by a second laser, one can further enhance the energy and number of photons produced provided the problems of synchronisation and compact γ-ray detection are solved. Here, we report on the work that has been done in developing an all-optical and hence, compact non-linear Thomson scattering source, including the new methods of synchronisation and compact γ-ray detection. We present evidence of the generation of multi-MeV (maximum 16–18 MeV) and ultra-high brilliance (exceeding 10{sup 20} photons s{sup −1}mm{sup −2}mrad{sup −2} 0.1% BW at 15 MeV) γ-ray beams. These characteristics are appealing for the paramount practical applications mentioned above. - Highlights: • How synchrotron radiation can be produced in an all optical setting using laser-plasmas. • Generating high-energy, high-flux gamma ray beams. • Presenting results from a recent NLTS experimental campaign. • Reveal insight into the experimental techniques employed.

  3. Efficient high-power narrow-linewidth all-fibred linearly polarized ytterbium laser source

    Science.gov (United States)

    Bertrand, Anthony; Liégeois, Flavien; Hernandez, Yves; Giannone, Domenico

    2012-06-01

    We report on experimental results on a high power, all-fibred, linearly polarized, mode-locked laser at 1.03 μm. The laser generates pulses of 40 ps wide at a repetition rate of 52 MHz, exhibiting 12 kW peak power. Dispersion in optical fibres is controlled to obtain both high power and narrow spectral linewidth. The average output power reached is 25 W with a spectral linewidth of 380 pm and a near diffraction limit beam (M2 < 1.2). This laser is an ideal candidate for applications like IR spectroscopy, where high peak power and narrow linewidth are required for subsequent wavelength conversion.

  4. High mortality in diabetic recipients of high KDPI deceased donor kidneys.

    Science.gov (United States)

    Pelletier, Ronald P; Pesavento, Todd E; Rajab, Amer; Henry, Mitchell L

    2016-08-01

    Deceased donor (DD) kidney quality is determined by calculating the Kidney Donor Profile Index (KDPI). Optimizing high KDPI (≥85%) DD transplant outcome is challenging. This retrospective study was performed to review our high KDPI DD transplant results to identify clinical practices that can improve future outcomes. We retrospectively calculated the KDPI for 895 DD kidney recipients transplanted between 1/2002 and 11/2013. Age, race, body mass index (BMI), retransplantation, gender, diabetes (DM), dialysis time, and preexisting coronary artery disease (CAD) (previous myocardial infarction (MI), coronary artery bypass (CABG), or stenting) were determined for all recipients. About 29.7% (266/895) of transplants were from donors with a KDPI ≥85%. By Cox regression older age, diabetes, female gender, and dialysis time >4 years correlated with shorter patient survival time. Diabetics with CAD who received a high KDPI donor kidney had a significantly increased risk of death (HR 4.33 (CI 1.82-10.30), P=.001) compared to low KDPI kidney recipients. The Kaplan-Meier survival curve for diabetic recipients of high KDPI kidneys was significantly worse if they had preexisting CAD (P<.001 by log-rank test). Patient survival using high KDPI donor kidneys may be improved by avoiding diabetic candidates with preexisting CAD. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Urinary tract infections in hospital pediatrics: many previous antibiotherapy and antibiotics resistance, including fluoroquinolones.

    Science.gov (United States)

    Garraffo, A; Marguet, C; Checoury, A; Boyer, S; Gardrat, A; Houivet, E; Caron, F

    2014-02-01

    We studied antibiotic resistance in pediatric UTIs and we evaluated the impact of antibiotic exposure in the previous 12 months, very little French data being available for this population. We conducted a multicenter prospective study including children consulting for, or admitted in 2 hospitals. Prior antibiotic exposure was documented from their health record. One hundred and ten patients (73 girls), 11 days to 12 years of age, were included in 10 months. Ninety-six percent presented with pyelonephritis, associated to uropathy for 25%. Escherichia coli was predominant (78%), followed by Proteus spp. and Enterococcus spp. The antibiotic resistance rate of E. coli was high and close to that reported for adults with complicated UTIs: amoxicillin 60%, amoxicillin-clavulanate 35%, cefotaxim 5%, trimethoprim-sulfametoxazole 26%, nalidixic acid 9%, ciprofloxacin 7%, gentamycin 1%, nitrofurantoin and fosfomycin 0%. The antibiotic exposure in the previous 12 months involved 62 children (56%) most frequently with β-lactams (89%) for a respiratory tract infection (56%). A clear relationship between exposure and resistance was observed for amoxicillin (71% vs. 46%), first generation (65% vs. 46%) and third generation (9% vs. 3%) cephalosporins, or trimethoprim-sulfamethoxazole (36% vs. 15%). However, antibiotic exposure could not account alone for the results, as suggested by the 7% of ciprofloxacin resistance, observed without any identified previous treatment. Bacterial species and antibiotic resistance level in children are similar to those reported for adults. Antibiotic exposure in the previous 12 months increases the risk of resistance but other factors are involved (previous antibiotic therapies and fecal-oral or mother-to-child transmission). Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. High-resolution seismic wave propagation using local time stepping

    KAUST Repository

    Peter, Daniel

    2017-03-13

    High-resolution seismic wave simulations often require local refinements in numerical meshes to accurately capture e.g. steep topography or complex fault geometry. Together with explicit time schemes, this dramatically reduces the global time step size for ground-motion simulations due to numerical stability conditions. To alleviate this problem, local time stepping (LTS) algorithms allow an explicit time stepping scheme to adapt the time step to the element size, allowing nearoptimal time steps everywhere in the mesh. This can potentially lead to significantly faster simulation runtimes.

  7. HIGH ALTITUDES EFFECTS ON HEMATOLOGIC BLOOD PARAMETERS

    Directory of Open Access Journals (Sweden)

    Hasim Rushiti

    2015-05-01

    Full Text Available The approach and the objective of this experiment are consistent with the determination of changes of blood parameters after the stay of the students at an altitude of 1800-2300 meters, for a ten-day long ski course. In this paper are included a total of 64 students of the Faculty of Sport Sciences in Prishtina, of the age group of 19-25 (the average age is 21. All students previously have undergone a medical check for TA, arterial pulse and respiratory rate. In particular, the health situation is of subjects was examined, then, all students, at the same time, gave blood for analysis. In this experiment, three main hematologic parameters were taken in consideration: such as hemoglobin, hematocrit and red blood cells. The same analyses were carried out after the 10-day stay at a high altitude. The results of the experiment have shown significant changes after the ten-day stay at high altitude, despite the previous results that show changes only after the twenty-day stay in such elevations.

  8. High-Speed Rail Train Timetabling Problem: A Time-Space Network Based Method with an Improved Branch-and-Price Algorithm

    Directory of Open Access Journals (Sweden)

    Bisheng He

    2014-01-01

    Full Text Available A time-space network based optimization method is designed for high-speed rail train timetabling problem to improve the service level of the high-speed rail. The general time-space path cost is presented which considers both the train travel time and the high-speed rail operation requirements: (1 service frequency requirement; (2 stopping plan adjustment; and (3 priority of train types. Train timetabling problem based on time-space path aims to minimize the total general time-space path cost of all trains. An improved branch-and-price algorithm is applied to solve the large scale integer programming problem. When dealing with the algorithm, a rapid branching and node selection for branch-and-price tree and a heuristic train time-space path generation for column generation are adopted to speed up the algorithm computation time. The computational results of a set of experiments on China’s high-speed rail system are presented with the discussions about the model validation, the effectiveness of the general time-space path cost, and the improved branch-and-price algorithm.

  9. Experimental Study on Hydrate Induction Time of Gas-Saturated Water-in-Oil Emulsion using a High-Pressure Flow Loop

    Directory of Open Access Journals (Sweden)

    Lv X.F.

    2015-11-01

    Full Text Available Hydrate is one of the critical precipitates which have to be controlled for subsea flow assurance. The induction time of hydrate is therefore a significant parameter. However, there have been few studies on the induction time of the natural gas hydrate formation in a flow loop system. Consequently, a series of experiments were firstly performed, including water, natural gas and Diesel oil, on the hydrate induction time under various conditions such as the supercooling and supersaturation degree, water cut, anti-agglomerant dosage, etc. The experiments were conducted in a high-pressure hydrate flow loop newly constructed in the China University of Petroleum (Beijing, and dedicated to flow assurance studies. Then, based on previous research, this study puts forward a method for induction time, which is characterized by clear definition, convenient measurement and good generality. Furthermore, we investigated the influences of the experimental parameters and analyzed the experimental phenomena for the hydrate induction time in a flowing system.

  10. Time to viral load suppression in antiretroviral-naive and -experienced HIV-infected pregnant women on highly active antiretroviral therapy: implications for pregnant women presenting late in gestation.

    Science.gov (United States)

    Aziz, N; Sokoloff, A; Kornak, J; Leva, N V; Mendiola, M L; Levison, J; Feakins, C; Shannon, M; Cohan, D

    2013-11-01

    To compare time to achieve viral load HIV-infected antiretroviral (ARV) -naive versus ARV-experienced pregnant women on highly active antiretroviral therapy (HAART). Retrospective cohort study. Three university medical centers, USA. HIV-infected pregnant women initiated or restarted on HAART during pregnancy. We calculated time to viral load HIV-infected pregnant women on HAART who reported at least 50% adherence, stratifying based on previous ARV exposure history. Time to HIV viral load HIV-infected pregnant women, comprising 76 ARV-naive and 62 ARV-experienced. Ninety-three percent of ARV-naive women achieved a viral load HIV log10 viral load was associated with a later time of achieving viral load HIV log10 viral load was associated with a longer time of achieving viral load Pregnant women with ≥50% adherence, whether ARV-naive or ARV-experienced, on average achieve a viral load HIV log10 viral load were all statistically significant predictors of earlier time to achieve viral load <400 copies/ml and <1000 copies/ml. Increased CD4 count was statistically significant as a predictor of earlier time to achieve viral load <1000 copies/ml. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.

  11. Synthesis of all-silica zeolites from highly concentrated gels containing hexamethonium cations

    KAUST Repository

    Liu, Xiaolong; Ravon, Ugo; Tuel, Alain

    2012-01-01

    A pure and highly crystalline all-silica EU-1 zeolite has been obtained from the crystallization of gels containing very low water contents in the presence of hexamethonium cations. Decreasing the water content in the gel down to H 2O/Si < 1

  12. Application of the electromagnetic borehole flowmeter and evaluation of previous pumping tests at Paducah Gaseous Diffusion Plant. Final report, June 15, 1992--August 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Young, S.C.; Julian, S.C.; Neton, M.J.

    1993-01-01

    Multi-well pumping tests have been concluded at wells MW79, MW108, and PW1 at the Paducah Gaseous Diffusion Plant (PGDP) to determine the hydraulic properties of the Regional Gravel Aquifer (RGA). Soil cores suggest that the RGA consists of a thin sandy facies (2 to 6 feet) at the top of a thicker (> 10 feet) gravelly facies. Previous analyses have not considered any permeability contrast between the two facies. To assess the accuracy of this assumption, TVA personnel conducted borehole flowmeter tests at wells MW108 and PW1. Well MW79 could not be tested. The high K sand unit is probably 10 times more permeable than comparable zone in the gravelly portion of the RGA. Previous analyses of the three multi-well aquifer tests do not use the same conceptual aquifer model. Data analysis for one pumping test assumed that leakance was significant. Data analysis for another pumping test assumed that a geologic boundary was significant. By collectively analyzing all three tests with the borehole flowmeter results, the inconsistency among the three pumping tests can be explained. Disparity exists because each pumping test had a different placement of observation wells relative to the high K zone delineating by flowmeter testing.

  13. 1846 and All That

    DEFF Research Database (Denmark)

    Sharp, Paul Richard

    By documenting the legislative history of the Corn Laws from 1670 and using previously unused data to calculate annual Ad Valorem Equivalents for most years from 1814, it is possible to establish several important facts about British wheat protection. Statutory protection was only significant...... for a few years after 1815, the decline starting in the 1820s and continuing beyond the famous “repeal” in 1846. The level of protection prior to 1846 was, for many years, much lower than previous accounts have suggested. The annual time series of Ad Valorem Equivalents will allow for UK trade policy...

  14. Circadian Clocks for All Meal-Times: Anticipation of 2 Daily Meals in Rats

    Science.gov (United States)

    Mistlberger, Ralph E.; Kent, Brianne A.; Chan, Sofina; Patton, Danica F.; Weinberg, Alexander; Parfyonov, Maksim

    2012-01-01

    Anticipation of a daily meal in rats has been conceptualized as a rest-activity rhythm driven by a food-entrained circadian oscillator separate from the pacemaker generating light-dark (LD) entrained rhythms. Rats can also anticipate two daily mealtimes, but whether this involves independently entrained oscillators, one ‘continuously consulted’ clock, cue-dependent non-circadian interval timing or a combination of processes, is unclear. Rats received two daily meals, beginning 3-h (meal 1) and 13-h (meal 2) after lights-on (LD 14∶10). Anticipatory wheel running began 68±8 min prior to meal 1 and 101±9 min prior to meal 2 but neither the duration nor the variability of anticipation bout lengths exhibited the scalar property, a hallmark of interval timing. Meal omission tests in LD and constant dark (DD) did not alter the timing of either bout of anticipation, and anticipation of meal 2 was not altered by a 3-h advance of meal 1. Food anticipatory running in this 2-meal protocol thus does not exhibit properties of interval timing despite the availability of external time cues in LD. Across all days, the two bouts of anticipation were uncorrelated, a result more consistent with two independently entrained oscillators than a single consulted clock. Similar results were obtained for meals scheduled 3-h and 10-h after lights-on, and for a food-bin measure of anticipation. Most rats that showed weak or no anticipation to one or both meals exhibited elevated activity at mealtime during 1 or 2 day food deprivation tests in DD, suggesting covert operation of circadian timing in the absence of anticipatory behavior. A control experiment confirmed that daytime feeding did not shift LD-entrained rhythms, ruling out displaced nocturnal activity as an explanation for daytime activity. The results favor a multiple oscillator basis for 2-meal anticipatory rhythms and provide no evidence for involvement of cue-dependent interval timing. PMID:22355393

  15. Real-time defect detection on highly reflective curved surfaces

    Science.gov (United States)

    Rosati, G.; Boschetti, G.; Biondi, A.; Rossi, A.

    2009-03-01

    This paper presents an automated defect detection system for coated plastic components for the automotive industry. This research activity came up as an evolution of a previous study which employed a non-flat mirror to illuminate and inspect high reflective curved surfaces. According to this method, the rays emitted from a light source are conveyed on the surface under investigation by means of a suitably curved mirror. After the reflection on the surface, the light rays are collected by a CCD camera, in which the coating defects appear as shadows of various shapes and dimensions. In this paper we present an evolution of the above-mentioned method, introducing a simplified mirror set-up in order to reduce the costs and the complexity of the defect detection system. In fact, a set of plane mirrors is employed instead of the curved one. Moreover, the inspection of multiple bend radius parts is investigated. A prototype of the machine vision system has been developed in order to test this simplified method. This device is made up of a light projector, a set of plane mirrors for light rays reflection, a conveyor belt for handling components, a CCD camera and a desktop PC which performs image acquisition and processing. Like in the previous system, the defects are identified as shadows inside a high brightness image. At the end of the paper, first experimental results are presented.

  16. Generation of high brightness ion beam from insulated anode PED

    International Nuclear Information System (INIS)

    Matsukawa, Yoshinobu

    1988-01-01

    Generation and focusing of a high density ion beam with high brightness from a organic center part of anode of a PED was reported previously. Mass, charge and energy distribution of this beam were analyzed. Three kind of anode were tried. Many highly ionized medium mass ions (up to C 4+ , O 6+ ) accelarated to several times of voltage difference between anode and cathode were observed. In the case of all insulator anode the current carried by the medium mass ions is about half of that carried by protons. (author)

  17. OptoDyCE: Automated system for high-throughput all-optical dynamic cardiac electrophysiology

    Science.gov (United States)

    Klimas, Aleksandra; Yu, Jinzhu; Ambrosi, Christina M.; Williams, John C.; Bien, Harold; Entcheva, Emilia

    2016-02-01

    In the last two decades, market were due to cardiac toxicity, where unintended interactions with ion channels disrupt the heart's normal electrical function. Consequently, all new drugs must undergo preclinical testing for cardiac liability, adding to an already expensive and lengthy process. Recognition that proarrhythmic effects often result from drug action on multiple ion channels demonstrates a need for integrative and comprehensive measurements. Additionally, patient-specific therapies relying on emerging technologies employing stem-cell derived cardiomyocytes (e.g. induced pluripotent stem-cell-derived cardiomyocytes, iPSC-CMs) require better screening methods to become practical. However, a high-throughput, cost-effective approach for cellular cardiac electrophysiology has not been feasible. Optical techniques for manipulation and recording provide a contactless means of dynamic, high-throughput testing of cells and tissues. Here, we consider the requirements for all-optical electrophysiology for drug testing, and we implement and validate OptoDyCE, a fully automated system for all-optical cardiac electrophysiology. We demonstrate the high-throughput capabilities using multicellular samples in 96-well format by combining optogenetic actuation with simultaneous fast high-resolution optical sensing of voltage or intracellular calcium. The system can also be implemented using iPSC-CMs and other cell-types by delivery of optogenetic drivers, or through the modular use of dedicated light-sensitive somatic cells in conjunction with non-modified cells. OptoDyCE provides a truly modular and dynamic screening system, capable of fully-automated acquisition of high-content information integral for improved discovery and development of new drugs and biologics, as well as providing a means of better understanding of electrical disturbances in the heart.

  18. Do family physicians retrieve synopses of clinical research previously read as email alerts?

    Science.gov (United States)

    Grad, Roland; Pluye, Pierre; Johnson-Lafleur, Janique; Granikov, Vera; Shulha, Michael; Bartlett, Gillian; Marlow, Bernard

    2011-11-30

    A synopsis of new clinical research highlights important aspects of one study in a brief structured format. When delivered as email alerts, synopses enable clinicians to become aware of new developments relevant for practice. Once read, a synopsis can become a known item of clinical information. In time-pressured situations, remembering a known item may facilitate information retrieval by the clinician. However, exactly how synopses first delivered as email alerts influence retrieval at some later time is not known. We examined searches for clinical information in which a synopsis previously read as an email alert was retrieved (defined as a dyad). Our study objectives were to (1) examine whether family physicians retrieved synopses they previously read as email alerts and then to (2) explore whether family physicians purposefully retrieved these synopses. We conducted a mixed-methods study in which a qualitative multiple case study explored the retrieval of email alerts within a prospective longitudinal cohort of practicing family physicians. Reading of research-based synopses was tracked in two contexts: (1) push, meaning to read on email and (2) pull, meaning to read after retrieval from one electronic knowledge resource. Dyads, defined as synopses first read as email alerts and subsequently retrieved in a search of a knowledge resource, were prospectively identified. Participants were interviewed about all of their dyads. Outcomes were the total number of dyads and their type. Over a period of 341 days, 194 unique synopses delivered to 41 participants resulted in 4937 synopsis readings. In all, 1205 synopses were retrieved over an average of 320 days. Of the 1205 retrieved synopses, 21 (1.7%) were dyads made by 17 family physicians. Of the 1205 retrieved synopses, 6 (0.5%) were known item type dyads. However, dyads also occurred serendipitously. In the single knowledge resource we studied, email alerts containing research-based synopses were rarely retrieved

  19. Timing of planned repeat cesarean delivery after two or more previous cesarean sections--risk for unplanned cesarean delivery and pregnancy outcome.

    Science.gov (United States)

    Melamed, Nir; Hadar, Eran; Keidar, Liron; Peled, Yoav; Wiznitzer, Arnon; Yogev, Yariv

    2014-03-01

    objective: To assess the effect of the scheduled gestational age for a repeat planned cesarean section (CS) on the risk for adverse pregnancy outcome in women with two or more previous CS. A retrospective cohort study of all women after ≥2 previous CS who were scheduled for a repeat planned CS. Women were divided into two groups at which the planned CS was scheduled: 38-week group or 39-week group. Overall, 377 were enrolled, 264 (70.0%) and 113 (30.0%) in the 38-week and the 39-week groups, respectively. The rate of an unplanned CS was significantly higher in the 39-week versus the 38-week group (23.0% versus 13.3%, p = 0.02). A repeat planned CS scheduled to week 39 was associated with an increased risk of maternal adverse outcome (31.9% versus 21.6%, p = 0.03). There was no significant difference in the rate of adverse neonatal outcome between the two groups (20.8% versus 23.0%, p = 0.5). The lowest rate of any adverse outcome (maternal and/or neonatal) was observed when CS was scheduled to 38 + 1 weeks of gestation. In women after two cesarean sections, scheduling a planned CS at around 39 weeks compared with at around 38 weeks is associated with an increased risk for maternal adverse outcome with no apparent advantage in terms of neonatal outcome.

  20. High-Cadence Transit Timing Variation Monitoring of Extrasolar Planets

    Directory of Open Access Journals (Sweden)

    Naef D.

    2011-02-01

    Full Text Available We report ground-based high-cadence transit timing observations of the extrasolar planet WASP-2b. We achieve a typical timing error of 15-30 sec. The data show no significant deviations from the predicted ephemeris.

  1. Origin of choriocarcinoma in previous molar pregnancy proved by DNA analysis

    International Nuclear Information System (INIS)

    Vojtassak, J.; Repiska, V.; Konecna, B.; Zajac, V.; Korbel, M.; Danihel, L.

    1996-01-01

    A 17-year old woman had in a short time period (seven months) a very exciting reproduction history. Molar pregnancy in December 1993, choriocarcinoma in January 1994 and induced abortion in June 1994. DNA analysis proved the origin of the choriocarcinoma in the previous molar pregnancy. (author)

  2. National Diet and Nutrition Survey: fat and fatty acid intakes from the first year of the rolling programme and comparison with previous surveys

    Science.gov (United States)

    Pot, Gerda K.; Prynne, Celia J.; Roberts, Caireen; Olson, Ashley; Nicholson, Sonja K.; Whitton, Clare; Teucher, Birgit; Bates, Beverley; Henderson, Helen; Pigott, Sarah; Swan, Gillian; Stephen, Alison M.

    2012-01-01

    High saturated fat intake is an established risk factor for several chronic diseases. The objective of the present study is to report dietary intakes and main food sources of fat and fatty acids (FA) from the first year of the National Diet and Nutrition Survey (NDNS) rolling programme in the UK. Dietary data were collected using 4d estimated food diaries (n896) and compared with dietary reference values (DRV) and previous NDNS results. Total fat provided 34–36% food energy (FE) across all age groups, which was similar to previous surveys for adults. Men (19–64 years) and older girls (11–18 years) had mean intakes just above the DRV, while all other groups had mean total fat intakes of <35% FE. SFA intakes were lower compared with previous surveys, ranging from 13 to 15% FE, but still above the DRV. Mean MUFA intakes were 12.5% FE for adults and children aged 4–18 years and all were below the DRV. Mean n–3 PUFA intake represented 0.7–1.1% FE. Compared with previous survey data, the direction of change for n–3 PUFA was upwards for all age groups, although the differences in absolute terms were very small. Trans-FA intakes were lower than in previous NDNS and were less than 2g/d for all age groups, representing 0.8% FE and lower than the DRV in all age groups. In conclusion, dietary intake of fat and FA is moving towards recommended levels for the UK population. However, there remains room for considerable further improvement. PMID:21767448

  3. High day- and night-time temperatures affect grain growth dynamics in contrasting rice genotypes.

    Science.gov (United States)

    Shi, Wanju; Yin, Xinyou; Struik, Paul C; Solis, Celymar; Xie, Fangming; Schmidt, Ralf C; Huang, Min; Zou, Yingbin; Ye, Changrong; Jagadish, S V Krishna

    2017-11-02

    Rice grain yield and quality are predicted to be highly vulnerable to global warming. Five genotypes including heat-tolerant and susceptible checks, a heat-tolerant near-isogenic line and two hybrids were exposed to control (31 °C/23 °C, day/night), high night-time temperature (HNT; 31 °C/30 °C), high day-time temperature (HDT; 38 °C/23 °C) and high day- and night-time temperature (HNDT; 38 °C/30 °C) treatments for 20 consecutive days during the grain-filling stage. Grain-filling dynamics, starch metabolism enzymes, temporal starch accumulation patterns and the process of chalk formation were quantified. Compensation between the rate and duration of grain filling minimized the impact of HNT, but irreversible impacts on seed-set, grain filling and ultimately grain weight were recorded with HDT and HNDT. Scanning electron microscopy demonstrated irregular and smaller starch granule formation affecting amyloplast build-up with HDT and HNDT, while a quicker but normal amylopast build-up was recorded with HNT. Our findings revealed temporal variation in the starch metabolism enzymes in all three stress treatments. Changes in the enzymatic activity did not derail starch accumulation under HNT when assimilates were sufficiently available, while both sucrose supply and the conversion of sucrose into starch were affected by HDT and HNDT. The findings indicate differential mechanisms leading to high day and high night temperature stress-induced loss in yield and quality. Additional genetic improvement is needed to sustain rice productivity and quality under future climates. © Society for Experimental Biology 2017.

  4. A high-throughput, multi-channel photon-counting detector with picosecond timing

    CERN Document Server

    Lapington, J S; Miller, G M; Ashton, T J R; Jarron, P; Despeisse, M; Powolny, F; Howorth, J; Milnes, J

    2009-01-01

    High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchanne...

  5. High-reflective colorful films fabricated by all-solid multi-layer cholesteric structures

    Science.gov (United States)

    Li, Y.; Luo, D.

    2018-02-01

    We demonstrate all-solid-state film with high-reflectivity based on cholesteric template. The adhesive (NOA81) is both filler and an adhesive, which can be avoids interfacial losses. The reflected right- and left-circularly polarized light has been developed by roll-to-roll method, and the reflectance of the films is more than 78%. Here, the all-solid film was used in distribute feedback laser with dye-doped. In addition, this films also used in include flexible reflective display, color pixels in digital photographs, printing and colored cladding of variety of objects.

  6. Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy

    Science.gov (United States)

    Kobayashi, Kiyonori; Mukae, Miyuki; Ogawa, Taishi; Yokoyama, Kaoru; Sada, Miwa; Koizumi, Wasaburo

    2013-01-01

    AIM: To evaluate the clinical usefulness of single-balloon endoscopy (SBE) in patients in whom a colonoscope was technically difficult to insert previously. METHODS: The study group comprised 15 patients (8 men and 7 women) who underwent SBE for colonoscopy (30 sessions). The number of SBE sessions was 1 in 7 patients, 2 in 5 patients, 3 in 1 patient, 4 in 1 patient, and 6 in 1 patient. In all patients, total colonoscopy was previously unsuccessful. The reasons for difficulty in scope passage were an elongated colon in 6 patients, severe intestinal adhesions after open surgery in 4, an elongated colon and severe intestinal adhesions in 2, a left inguinal hernia in 2, and multiple diverticulosis of the sigmoid colon in 1. Three endoscopists were responsible for SBE. The technique for inserting SBE in the colon was basically similar to that in the small intestine. The effectiveness of SBE was assessed on the basis of the success rate of total colonoscopy and the presence or absence of complications. We also evaluated the diagnostic and treatment outcomes of colonoscopic examinations with SBE. RESULTS: Total colonoscopy was successfully accomplished in all sessions. The mean insertion time to the cecum was 22.9 ± 8.9 min (range 9 to 40). Abnormalities were found during 21 sessions of SBE. The most common abnormality was colorectal polyps (20 sessions), followed by radiation colitis (3 sessions) and diverticular disease of the colon (3 sessions). Colorectal polyps were resected endoscopically in 15 sessions. A total of 42 polyps were resected endoscopically, using snare polypectomy in 32 lesions, hot biopsy in 7 lesions, and endoscopic mucosal resection in 3 lesions. Fifty-six colorectal polyps were newly diagnosed on colonoscopic examination with SBE. Histopathologically, these lesions included 2 intramucosal cancers, 42 tubular adenomas, and 2 tubulovillous adenomas. The mean examination time was 48.2 ± 20.0 min (range 25 to 90). Colonoscopic examination or

  7. Time correlation between mononucleosis and initial symptoms of MS

    Science.gov (United States)

    Endriz, John; Ho, Peggy P.

    2017-01-01

    Objective: To determine the average age of MS onset vs the age at which Epstein-Barr infection has previously occurred and stratify this analysis by sex and the blood level of Epstein-Barr nuclear antigen 1 (EBNA1) antibody. Methods: Using infectious mononucleosis (IM) as a temporal marker in data from the Swedish epidemiologic investigation of MS, 259 adult IM/MS cases were identified and then augmented to account for “missing” childhood data so that the average age of MS onset could be determined for cases binned by age of IM (as stratified by sex and EBNA1 titer level). Results: Mean age of IM vs mean age of MS reveals a positive time correlation for all IM ages (from ∼5 to ∼30 years), with IM-to-MS delay decreasing with increased age. When bifurcated by sex or EBNA1 blood titer levels, males and high-titer subpopulations show even stronger positive time correlation, while females and low-titer populations show negative time correlation in early childhood (long IM/MS delay). The correlation becomes positive in females beyond puberty. Conclusions: IM/MS time correlation implies causality if IM is time random. Alternative confounding models seem implausible, in light of constraints imposed by time-invariant delay observed here. Childhood infection with Epstein-Barr virus (EBV) in females and/or those genetically prone to low EBNA1 blood titers will develop MS slowly. Males and/or high EBNA1-prone develop MS more rapidly following IM infection at all ages. For all, postpubescent EBV infection is critical for the initiation and rapid development of MS. PMID:28271078

  8. One-against-all weighted dynamic time warping for language-independent and speaker-dependent speech recognition in adverse conditions.

    Directory of Open Access Journals (Sweden)

    Xianglilan Zhang

    Full Text Available Considering personal privacy and difficulty of obtaining training material for many seldom used English words and (often non-English names, language-independent (LI with lightweight speaker-dependent (SD automatic speech recognition (ASR is a promising option to solve the problem. The dynamic time warping (DTW algorithm is the state-of-the-art algorithm for small foot-print SD ASR applications with limited storage space and small vocabulary, such as voice dialing on mobile devices, menu-driven recognition, and voice control on vehicles and robotics. Even though we have successfully developed two fast and accurate DTW variations for clean speech data, speech recognition for adverse conditions is still a big challenge. In order to improve recognition accuracy in noisy environment and bad recording conditions such as too high or low volume, we introduce a novel one-against-all weighted DTW (OAWDTW. This method defines a one-against-all index (OAI for each time frame of training data and applies the OAIs to the core DTW process. Given two speech signals, OAWDTW tunes their final alignment score by using OAI in the DTW process. Our method achieves better accuracies than DTW and merge-weighted DTW (MWDTW, as 6.97% relative reduction of error rate (RRER compared with DTW and 15.91% RRER compared with MWDTW are observed in our extensive experiments on one representative SD dataset of four speakers' recordings. To the best of our knowledge, OAWDTW approach is the first weighted DTW specially designed for speech data in adverse conditions.

  9. High-k shallow traps observed by charge pumping with varying discharging times

    International Nuclear Information System (INIS)

    Ho, Szu-Han; Chen, Ching-En; Tseng, Tseung-Yuen; Chang, Ting-Chang; Lu, Ying-Hsin; Lo, Wen-Hung; Tsai, Jyun-Yu; Liu, Kuan-Ju; Wang, Bin-Wei; Cao, Xi-Xin; Chen, Hua-Mao; Cheng, Osbert; Huang, Cheng-Tung; Chen, Tsai-Fu

    2013-01-01

    In this paper, we investigate the influence of falling time and base level time on high-k bulk shallow traps measured by charge pumping technique in n-channel metal-oxide-semiconductor field-effect transistors with HfO 2 /metal gate stacks. N T -V high level characteristic curves with different duty ratios indicate that the electron detrapping time dominates the value of N T for extra contribution of I cp traps. N T is the number of traps, and I cp is charge pumping current. By fitting discharge formula at different temperatures, the results show that extra contribution of I cp traps at high voltage are in fact high-k bulk shallow traps. This is also verified through a comparison of different interlayer thicknesses and different Ti x N 1−x metal gate concentrations. Next, N T -V high level characteristic curves with different falling times (t falling time ) and base level times (t base level ) show that extra contribution of I cp traps decrease with an increase in t falling time . By fitting discharge formula for different t falling time , the results show that electrons trapped in high-k bulk shallow traps first discharge to the channel and then to source and drain during t falling time . This current cannot be measured by the charge pumping technique. Subsequent measurements of N T by charge pumping technique at t base level reveal a remainder of electrons trapped in high-k bulk shallow traps

  10. Spinal Arachnoiditis as a Complication of Cryptococcal Meningoencephalitis in Non-HIV Previously Healthy Adults

    Science.gov (United States)

    Komori, Mika; Kosa, Peter; Khan, Omar; Hammoud, Dima A.; Rosen, Lindsey B.; Browne, Sarah K.; Lin, Yen-Chih; Romm, Elena; Ramaprasad, Charu; Fries, Bettina C.; Bennett, John E.; Bielekova, Bibiana; Williamson, Peter R.

    2017-01-01

    Background. Cryptococcus can cause meningoencephalitis (CM) among previously healthy non-HIV adults. Spinal arachnoiditis is under-recognized, since diagnosis is difficult with concomitant central nervous system (CNS) pathology. Methods. We describe 6 cases of spinal arachnoiditis among 26 consecutively recruited CM patients with normal CD4 counts who achieved microbiologic control. We performed detailed neurological exams, cerebrospinal fluid (CSF) immunophenotyping and biomarker analysis before and after adjunctive immunomodulatory intervention with high dose pulse corticosteroids, affording causal inference into pathophysiology. Results. All 6 exhibited severe lower motor neuron involvement in addition to cognitive changes and gait disturbances from meningoencephalitis. Spinal involvement was associated with asymmetric weakness and urinary retention. Diagnostic specificity was improved by MRI imaging which demonstrated lumbar spinal nerve root enhancement and clumping or lesions. Despite negative fungal cultures, CSF inflammatory biomarkers, sCD27 and sCD21, as well as the neuronal damage biomarker, neurofilament light chain (NFL), were elevated compared to healthy donor (HD) controls. Elevations in these biomarkers were associated with clinical symptoms and showed improvement with adjunctive high dose pulse corticosteroids. Conclusions. These data suggest that a post-infectious spinal arachnoiditis is an important complication of CM in previously healthy individuals, requiring heightened clinician awareness. Despite microbiological control, this syndrome causes significant pathology likely due to increased inflammation and may be amenable to suppressive therapeutics. PMID:28011613

  11. Enhanced intensity dependence and aggression history indicate previous regular ecstasy use in abstinent polydrug users.

    Science.gov (United States)

    Wan, Li; Baldridge, Robyn M; Colby, Amanda M; Stanford, Matthew S

    2009-11-13

    Intensity dependence is an electrophysiological measure of intra-individual stability of the augmenting/reducing characteristic of N1/ P2 event-related potential amplitudes in response to stimuli of varying intensities. Abstinent ecstasy users typically show enhanced intensity dependence and higher levels of impulsivity and aggression. Enhanced intensity dependence and high impulsivity and aggression levels may be due to damage in the brain's serotonergic neurons as a result of ecstasy use. The present study investigated whether intensity dependence, impulsivity and aggression history can be used as indicators of previous chronic ecstasy usage. Forty-four abstinent polydrug users (8 women; age 19 to 61 years old) were recruited. All participants were currently residents at a local substance abuse facility receiving treatment and had been free of all drugs for a minimum of 21 days. The study found significantly enhanced intensity dependence of tangential dipole source activity and a history of more aggressive behavior in those who had previously been involved in chronic ecstasy use. Intensity dependence of the tangential dipole source and aggressive behavior history correctly identified 73.3% of those who had been regular ecstasy users and 78.3% of those who had not. Overall, 76.3% of the participants were correctly classified.

  12. Real-time, high frequency QRS electrocardiograph with reduced amplitude zone detection

    Science.gov (United States)

    Schlegel, Todd T. (Inventor); DePalma, Jude L. (Inventor); Moradi, Saeed (Inventor)

    2009-01-01

    Real time cardiac electrical data are received from a patient, manipulated to determine various useful aspects of the ECG signal, and displayed in real time in a useful form on a computer screen or monitor. The monitor displays the high frequency data from the QRS complex in units of microvolts, juxtaposed with a display of conventional ECG data in units of millivolts or microvolts. The high frequency data are analyzed for their root mean square (RMS) voltage values and the discrete RMS values and related parameters are displayed in real time. The high frequency data from the QRS complex are analyzed with imbedded algorithms to determine the presence or absence of reduced amplitude zones, referred to herein as ''RAZs''. RAZs are displayed as ''go, no-go'' signals on the computer monitor. The RMS and related values of the high frequency components are displayed as time varying signals, and the presence or absence of RAZs may be similarly displayed over time.

  13. Short-time, high-dosage penicillin infusion therapy of syphilis

    DEFF Research Database (Denmark)

    Lomholt, Hans; Poulsen, Asmus; Brandrup, Flemming

    2003-01-01

    The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G intraven......The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G...

  14. Magneto-optical system for high speed real time imaging

    Science.gov (United States)

    Baziljevich, M.; Barness, D.; Sinvani, M.; Perel, E.; Shaulov, A.; Yeshurun, Y.

    2012-08-01

    A new magneto-optical system has been developed to expand the range of high speed real time magneto-optical imaging. A special source for the external magnetic field has also been designed, using a pump solenoid to rapidly excite the field coil. Together with careful modifications of the cryostat, to reduce eddy currents, ramping rates reaching 3000 T/s have been achieved. Using a powerful laser as the light source, a custom designed optical assembly, and a high speed digital camera, real time imaging rates up to 30 000 frames per seconds have been demonstrated.

  15. High precision pulsar timing and spin frequency second derivatives

    Science.gov (United States)

    Liu, X. J.; Bassa, C. G.; Stappers, B. W.

    2018-05-01

    We investigate the impact of intrinsic, kinematic and gravitational effects on high precision pulsar timing. We present an analytical derivation and a numerical computation of the impact of these effects on the first and second derivative of the pulsar spin frequency. In addition, in the presence of white noise, we derive an expression to determine the expected measurement uncertainty of a second derivative of the spin frequency for a given timing precision, observing cadence and timing baseline and find that it strongly depends on the latter (∝t-7/2). We show that for pulsars with significant proper motion, the spin frequency second derivative is dominated by a term dependent on the radial velocity of the pulsar. Considering the data sets from three Pulsar Timing Arrays, we find that for PSR J0437-4715 a detectable spin frequency second derivative will be present if the absolute value of the radial velocity exceeds 33 km s-1. Similarly, at the current timing precision and cadence, continued timing observations of PSR J1909-3744 for about another eleven years, will allow the measurement of its frequency second derivative and determine the radial velocity with an accuracy better than 14 km s-1. With the ever increasing timing precision and observing baselines, the impact of the, largely unknown, radial velocities of pulsars on high precision pulsar timing can not be neglected.

  16. High energy resolution and first time-dependent positron annihilation induced Auger electron spectroscopty

    International Nuclear Information System (INIS)

    Mayer, Jakob

    2010-01-01

    It was the aim of this thesis to improve the existing positron annihilation induced Auger spectrometer at the highly intense positron source NEPOMUC (NEutron induced POsitron source MUniCh) in several ways: Firstly, the measurement time for a single spectrum should be reduced from typically 12 h to roughly 1 h or even less. Secondly, the energy resolution, which amounted to ΔE/E∼10%, should be increased by at least one order of magnitude in order to make high resolution positron annihilation induced Auger spectroscopy (PAES)-measurements of Auger transitions possible and thus deliver more information about the nature of the Auger process. In order to achieve these objectives, the PAES spectrometer was equipped with a new electron energy analyzer. For its ideal operation all other components of the Auger analysis chamber had to be adapted. Particularly the sample manipulation and the positron beam guidance had to be renewed. Simulations with SIMION registered ensured the optimal positron lens parameters. After the adjustment of the new analyzer and its components, first measurements illustrated the improved performance of the PAES setup: Firstly, the measurement time for short overview measurements was reduced from 3 h to 420 s. The measurement time for more detailed Auger spectra was shortened from 12 h to 80 min. Secondly, even with the reduced measurement time, the signal to noise ratio was also enhanced by one order of magnitude. Finally, the energy resolution was improved to ΔE/E 2,3 VV-transition with PAES. Thus, within this thesis two objectives were achieved: Firstly, the PAES spectrometer was renewed and improved by at least one order of magnitude with respect to the signal to noise ratio, the measurement time and the energy resolution. Secondly, several measurements have been carried out, demonstrating the high performance of the spectrometer. Amongst them are first dynamic PAES measurements and a high resolution measurement of the CuM 2,3 VV

  17. Charged-particle thermonuclear reaction rates: IV. Comparison to previous work

    International Nuclear Information System (INIS)

    Iliadis, C.; Longland, R.; Champagne, A.E.; Coc, A.

    2010-01-01

    We compare our Monte Carlo reaction rates (see Paper II of this issue) to previous results that were obtained by using the classical method of computing thermonuclear reaction rates. For each reaction, the comparison is presented using two types of graphs: the first shows the change in reaction rate uncertainties, while the second displays our new results normalized to the previously recommended reaction rate. We find that the rates have changed significantly for almost all reactions considered here. The changes are caused by (i) our new Monte Carlo method of computing reaction rates (see Paper I of this issue), and (ii) newly available nuclear physics information (see Paper III of this issue).

  18. Open heart surgery with deep hypothermic cardiopulmonary bypass and more than 90 minutes of aortic cross clamp time in 10 small dogs

    Directory of Open Access Journals (Sweden)

    Kippei Mihara

    2017-04-01

    Full Text Available No previous reports have described cardiopulmonary bypass (CPB techniques involving long aortic cross clamp (ACC times in small-breed dogs. We previously described open heart surgery under deep hypothermic CPB in small and toy dogs with an approximate ACC time limit of 1 hour, given the low success rate beyond 90 minutes of ACC time. Herein, we describe improvements in cardiac anesthesia, CPB, and cardioplegia that led to a high success rate of open heart surgery with a long ACC time in small dogs. Ten small-breed dogs with severe mitral regurgitation were subjected to mitral valve plasty that necessitated cardiopulmonary bypass (CPB beyond 90 minutes of ACC time. In the present study, all dogs survived surgery; 7 survived to discharge. In other words, we achieved a high success rate of 70% with mitral valve plasty beyond 90 minutes of ACC time (mean, 105.1 minutes: range, 90-117 minutes. For small dogs, successful open heart surgery with a long ACC time may require cardiac balanced anesthesia, CPB with increased drainage and, importantly, thorough cardioplegia without hemodilution.

  19. Effects of organic carbon supply rates on uranium mobility in a previously bioreduced contaminated sediment.

    Science.gov (United States)

    Wan, Jiamin; Tokunaga, Tetsu K; Kim, Yongman; Brodie, Eoin; Daly, Rebecca; Hazen, Terry C; Firestone, Mary K

    2008-10-15

    Bioreduction-based strategies for remediating uranium (U)-contaminated sediments face the challenge of maintaining the reduced status of U for long times. Because groundwater influxes continuously bring in oxidizing terminal electron acceptors (O2, NO3(-)), it is necessary to continue supplying organic carbon (OC) to maintain the reducing environment after U bioreduction is achieved. We tested the influence of OC supply rates on mobility of previously microbial reduced uranium U(IV) in contaminated sediments. We found that high degrees of U mobilization occurred when OC supply rates were high, and when the sediment still contained abundant Fe(III). Although 900 days with low levels of OC supply minimized U mobilization, the sediment redox potential increased with time as did extractable U(VI) fractions. Molecular analyses of total microbial activity demonstrated a positive correlation with OC supply and analyses of Geobacteraceae activity (RT-qPCR of 16S rRNA) indicated continued activity even when the effluent Fe(II) became undetectable. These data support our hypothesis on the mechanisms responsible for remobilization of U under reducing conditions; that microbial respiration caused increased (bi)carbonate concentration and formation of stable uranyl carbonate complexes, thereby shifted U(IV)/U(VI) equilibrium to more reducing potentials. The data also suggested that low OC concentrations could not sustain the reducing condition of the sediment for much longer time. Bioreduced U(IV) is not sustainable in an oxidizing environment for a very long time.

  20. Modelling the cosmic spectral energy distribution and extragalactic background light over all time

    Science.gov (United States)

    Andrews, S. K.; Driver, S. P.; Davies, L. J. M.; Lagos, C. d. P.; Robotham, A. S. G.

    2018-02-01

    We present a phenomological model of the cosmic spectral energy distribution (CSED) and the integrated galactic light (IGL) over all cosmic time. This model, based on an earlier model by Driver et al., attributes the cosmic star formation history (CSFH) to two processes - first, chaotic clump accretion and major mergers, resulting in the early-time formation of bulges and secondly, cold gas accretion, resulting in late-time disc formation. Under the assumption of a Universal Chabrier initial mass function, we combine the Bruzual & Charlot stellar libraries, the Charlot & Fall dust attenuation prescription and template spectra for emission by dust and active galactic nuclei to predict the CSED - pre- and post-dust attenuation - and the IGL throughout cosmic time. The phenomological model, as constructed, adopts a number of basic axioms and empirical results and has minimal free parameters. We compare the model output, as well as predictions from the semi-analytic model GALFORM to recent estimates of the CSED out to z = 1. By construction, our empirical model reproduces the full energy output of the Universe from the ultraviolet to the far-infrared extremely well. We use the model to derive predictions of the stellar and dust mass densities, again finding good agreement. We find that GALFORM predicts the CSED for z < 0.3 in good agreement with the observations. This agreement becomes increasingly poor towards z = 1, when the model CSED is ˜50 per cent fainter. The latter is consistent with the model underpredicting the CSFH. As a consequence, GALFORM predicts a ˜30 per cent fainter IGL.

  1. Highly Integrated Mixed-Mode Electronics for the readout of Time Projection Chambers

    CERN Document Server

    França Santos, Hugo Miguel; Musa, Luciano

    Time Projection Chambers (TPCs) are one of the most prevalent particle trackers for high-energy physics experiments. Future planed TPCs for the International Linear Collider (ILC) and the Compact Linear Collider (CLIC) entail very high spatial resolution in large gas volumes, but impose low material budget for the end caps of the TPC cylinder. This constraint is not accomplished with the state-of-the-art front-end electronics because of its unsuited relatively large mass and of its associated water cooling system. To reach the required material budget, highly compact and power efficient dedicated TPC front-end electronics should be developed. This project aims at re-designing the different electronic elements with significant improvements in terms of performance, power efficiency and versatility, and developing an integrated circuit that merges all components of the front-end electronics. This chip ambitions a large volume production at low unitary cost and its employment in multiple detectors. The design of ...

  2. It's all in the timing: calibrating temporal penalties for biomedical data sharing.

    Science.gov (United States)

    Xia, Weiyi; Wan, Zhiyu; Yin, Zhijun; Gaupp, James; Liu, Yongtai; Clayton, Ellen Wright; Kantarcioglu, Murat; Vorobeychik, Yevgeniy; Malin, Bradley A

    2018-01-01

    Biomedical science is driven by datasets that are being accumulated at an unprecedented rate, with ever-growing volume and richness. There are various initiatives to make these datasets more widely available to recipients who sign Data Use Certificate agreements, whereby penalties are levied for violations. A particularly popular penalty is the temporary revocation, often for several months, of the recipient's data usage rights. This policy is based on the assumption that the value of biomedical research data depreciates significantly over time; however, no studies have been performed to substantiate this belief. This study investigates whether this assumption holds true and the data science policy implications. This study tests the hypothesis that the value of data for scientific investigators, in terms of the impact of the publications based on the data, decreases over time. The hypothesis is tested formally through a mixed linear effects model using approximately 1200 publications between 2007 and 2013 that used datasets from the Database of Genotypes and Phenotypes, a data-sharing initiative of the National Institutes of Health. The analysis shows that the impact factors for publications based on Database of Genotypes and Phenotypes datasets depreciate in a statistically significant manner. However, we further discover that the depreciation rate is slow, only ∼10% per year, on average. The enduring value of data for subsequent studies implies that revoking usage for short periods of time may not sufficiently deter those who would violate Data Use Certificate agreements and that alternative penalty mechanisms may need to be invoked. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  3. X-ray time lags in PG 1211+143

    Science.gov (United States)

    Lobban, A. P.; Vaughan, S.; Pounds, K.; Reeves, J. N.

    2018-05-01

    We investigate the X-ray time lags of a recent ˜630 ks XMM-Newton observation of PG 1211+143. We find well-correlated variations across the XMM-Newton EPIC bandpass, with the first detection of a hard lag in this source with a mean time delay of up to ˜3 ks at the lowest frequencies. We find that the energy-dependence of the low-frequency hard lag scales approximately linearly with log(E) when averaged over all orbits, consistent with the propagating fluctuations model. However, we find that the low-frequency lag behaviour becomes more complex on time-scales longer than a single orbit, suggestive of additional modes of variability. We also detect a high-frequency soft lag at ˜10-4 Hz with the magnitude of the delay peaking at ≲ 0.8 ks, consistent with previous observations, which we discuss in terms of small-scale reverberation.

  4. Optical Time-Division Multiplexing of 10 Gbit/s Ethernet Signals Synchronized by All-Optical Signal Processing Based on a Time-Lens

    DEFF Research Database (Denmark)

    Areal, Janaina Laguardia

    This Thesis presents 3 years work of an optical circuit that performs both pulse compression and frame synchronization and retiming. Our design aims at directly multiplexing several 10G Ethernet data packets (frames) to a high-speed OTDM link. This scheme is optically transparent and does not req...... coupler, completing the OTDM signal generation. We demonstrate the effectiveness of the design by laboratory experiments and simulations with VPI and MatLab....... not require clock recovery, resulting in a potentially very efficient solution. The scheme uses a time-lens, implemented through a sinusoidally driven optical phase modulation, combined with a linear dispersion element. As time-lenses are also used for pulse compression, we design the circuit also to perform...

  5. Managing high-bandwidth real-time data storage

    Energy Technology Data Exchange (ETDEWEB)

    Bigelow, David D. [Los Alamos National Laboratory; Brandt, Scott A [Los Alamos National Laboratory; Bent, John M [Los Alamos National Laboratory; Chen, Hsing-Bung [Los Alamos National Laboratory

    2009-09-23

    There exist certain systems which generate real-time data at high bandwidth, but do not necessarily require the long-term retention of that data in normal conditions. In some cases, the data may not actually be useful, and in others, there may be too much data to permanently retain in long-term storage whether it is useful or not. However, certain portions of the data may be identified as being vitally important from time to time, and must therefore be retained for further analysis or permanent storage without interrupting the ongoing collection of new data. We have developed a system, Mahanaxar, intended to address this problem. It provides quality of service guarantees for incoming real-time data streams and simultaneous access to already-recorded data on a best-effort basis utilizing any spare bandwidth. It has built in mechanisms for reliability and indexing, can scale upwards to meet increasing bandwidth requirements, and handles both small and large data elements equally well. We will show that a prototype version of this system provides better performance than a flat file (traditional filesystem) based version, particularly with regard to quality of service guarantees and hard real-time requirements.

  6. Ultra-high throughput real-time instruments for capturing fast signals and rare events

    Science.gov (United States)

    Buckley, Brandon Walter

    processing. The act of time-stretching effectively boosts the performance of the back-end electronics and digital signal processors. The slowed down signals reach the back-end electronics with reduced bandwidth, and are therefore less affected by high-frequency roll-off and distortion. Time-stretching also increases the effective sampling rate of analog-to-digital converters and reduces aperture jitter, thereby improving resolution. Finally, the instantaneous throughputs of digital signal processors are enhanced by the stretch factor to otherwise unattainable speeds. Leveraging these unique capabilities, TiSER becomes the ideal tool for capturing high-speed signals and characterizing rare phenomena. For this thesis, I have developed techniques to improve the spectral efficiency, bandwidth, and resolution of TiSER using polarization multiplexing, all-optical modulation, and coherent dispersive Fourier transformation. To reduce the latency and improve the data handling capacity, I have also designed and implemented a real-time digital signal processing electronic backend, achieving 1.5 tera-bit per second instantaneous processing throughput. Finally, I will present results from experiments highlighting TiSER's impact in real-world applications. Confocal fluorescence microscopy is the most widely used method for unveiling the molecular composition of biological specimens. However, the weak optical emission of fluorescent probes and the tradeoff between imaging speed and sensitivity is problematic for acquiring blur-free images of fast phenomena and cells flowing at high speed. Here I introduce a new fluorescence imaging modality, which leverages techniques from wireless communication to reach record pixel and frame rates. Termed Fluorescence Imaging using Radio-frequency tagged Emission (FIRE), this new imaging modality is capable of resolving never before seen dynamics in living cells - such as action potentials in neurons and metabolic waves in astrocytes - as well as

  7. The environmental Kuznets curve. Does one size fit all?

    International Nuclear Information System (INIS)

    List, J.A.; Gallet, C.A.

    1999-01-01

    This paper uses a new panel data set on state-level sulfur dioxide and nitrogen oxide emissions from 1929-1994 to test the appropriateness of the 'one size fits all' reduced-form regression approach commonly used in the environmental Kuznets curve literature. Empirical results provide initial evidence that an inverted-U shape characterizes the relationship between per capita emissions and per capita incomes at the state level. Parameter estimates suggest, however, that previous studies, which restrict cross-sections to undergo identical experiences over time, may be presenting statistically biased results. 25 refs

  8. Ferroelectric BiFeO3 as an Oxide Dye in Highly Tunable Mesoporous All-Oxide Photovoltaic Heterojunctions.

    Science.gov (United States)

    Wang, Lingfei; Ma, He; Chang, Lei; Ma, Chun; Yuan, Guoliang; Wang, Junling; Wu, Tom

    2017-01-01

    As potential photovoltaic materials, transition-metal oxides such as BiFeO 3 (BFO) are capable of absorbing a substantial portion of solar light and incorporating ferroic orders into solar cells with enhanced performance. But the photovoltaic application of BFO has been hindered by low energy-conversion efficiency due to poor carrier transport and collection. In this work, a new approach of utilizing BFO as a light-absorbing sensitizer is developed to interface with charge-transporting TiO 2 nanoparticles. This mesoporous all-oxide architecture, similar to that of dye-sensitized solar cells, can effectively facilitate the extraction of photocarriers. Under the standard AM1.5 (100 mW cm -2 ) irradiation, the optimized cell shows an open-circuit voltage of 0.67 V, which can be enhanced to 1.0 V by tailoring the bias history. A fill factor of 55% is achieved, which is much higher than those in previous reports on BFO-based photovoltaic devices. The results provide here a new viable approach toward developing highly tunable and stable photovoltaic devices based on ferroelectric transition-metal oxides. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. HIGH-TIME-RESOLUTION MEASUREMENTS OF THE POLARIZATION OF THE CRAB PULSAR AT 1.38 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Słowikowska, Agnieszka [Kepler Institute of Astronomy, University of Zielona Góra, Lubuska 2, 65-265 Zielona Góra (Poland); Stappers, Benjamin W. [Jodrell Bank Centre for Astrophysics, University of Manchester, Manchester M13 9PL (United Kingdom); Harding, Alice K. [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); O' Dell, Stephen L.; Elsner, Ronald F.; Weisskopf, Martin C. [Astrophysics Office, NASA Marshall Space Flight Center, ZP12, Huntsville, AL 35812 (United States); Van der Horst, Alexander J. [Astronomical Institute, University of Amsterdam, Science Park 904, 1098 XH Amsterdam (Netherlands)

    2015-01-20

    Using the Westerbork Synthesis Radio Telescope, we obtained high-time-resolution measurements of the full polarization of the Crab pulsar. At a resolution of 1/8192 of the 34 ms pulse period (i.e., 4.1 μs), the 1.38 GHz linear-polarization measurements are in general agreement with previous lower-time-resolution 1.4 GHz measurements of linear polarization in the main pulse (MP), in the interpulse (IP), and in the low-frequency component (LFC). We find the MP and IP to be linearly polarized at about 24% and 21% with no discernible difference in polarization position angle. However, contrary to theoretical expectations and measurements in the visible, we find no evidence for significant variation (sweep) in the polarization position angle over the MP, the IP, or the LFC. We discuss the implications, which appear to be in contradiction to theoretical expectations. We also detect weak circular polarization in the MP and IP, and strong (≈20%) circular polarization in the LFC, which also exhibits very strong (≈98%) linear polarization at a position angle of 40° from that of the MP or IP. The properties are consistent with the LFC, which is a low-altitude component, and the MP and IP, which are high-altitude caustic components. Current models for the MP and IP emission do not readily account for the absence of pronounced polarization changes across the pulse. We measure IP and LFC pulse phases relative to the MP consistent with recent measurements, which have shown that the phases of these pulse components are evolving with time.

  10. Development of a highly sensitive one-tube nested real-time PCR for detecting Mycobacterium tuberculosis.

    Science.gov (United States)

    Choi, Yeonim; Jeon, Bo-Young; Shim, Tae Sun; Jin, Hyunwoo; Cho, Sang-Nae; Lee, Hyeyoung

    2014-12-01

    Rapid, accurate detection of Mycobacterium tuberculosis is crucial in the diagnosis of tuberculosis (TB), but conventional diagnostic methods have limited sensitivity and specificity or are time consuming. A new highly sensitive nucleic acid amplification test, combined nested and real-time polymerase chain reaction (PCR) in a single tube (one-tube nested real-time PCR), was developed for detecting M. tuberculosis, which takes advantage of two PCR techniques, i.e., nested PCR and real-time PCR. One-tube nested real-time PCR was designed to have two sequential reactions with two sets of primers and dual probes for the insertion sequence (IS) 6110 sequence of M. tuberculosis in a single closed tube. The minimum limits of detection of IS6110 real-time PCR and IS6110 one-tube nested real-time PCR were 100 fg/μL and 1 fg/μL of M. tuberculosis DNA, respectively. AdvanSure TB/non-tuberculous mycobacteria (NTM) real-time PCR, IS6110 real-time PCR, and two-tube nested real-time PCR showed 100% sensitivity and 100% specificity for clinical M. tuberculosis isolates and NTM isolates. In comparison, the sensitivities of AdvanSure TB/NTM real-time PCR, single IS6110 real-time PCR, and one-tube nested real-time PCR were 91% (152/167), 94.6% (158/167), and 100% (167/167) for sputum specimens, respectively. In conclusion, IS6110 one-tube nested real-time PCR is useful for detecting M. tuberculosis due to its high sensitivity and simple manipulation. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. A Facile All-Solution-Processed Surface with High Water Contact Angle and High Water Adhesive Force.

    Science.gov (United States)

    Chen, Mei; Hu, Wei; Liang, Xiao; Zou, Cheng; Li, Fasheng; Zhang, Lanying; Chen, Feiwu; Yang, Huai

    2017-07-12

    A series of sticky superhydrophobicity surfaces with high water contact angle and high water adhesive force is facilely prepared via an all-solution-processed method based on polymerization-induced phase separation between liquid crystals (LCs) and epoxy resin, which produces layers of epoxy microspheres (EMSs) with nanofolds on the surface of a substrate. The morphologies and size distributions of EMSs are confirmed by scanning electron microscopy. Results reveal that the obtained EMS coated-surface exhibits high apparent contact angle of 152.0° and high water adhesive force up to 117.6 μN. By varying the composition of the sample or preparing conditions, the sizes of the produced EMSs can be artificially regulated and, thus, control the wetting properties and water adhesive behaviors. Also, the sticky superhydrophobic surface exhibits excellent chemical stability, as well as long-term durability. Water droplet transportation experiments further prove that the as-made surface can be effectively used as a mechanical hand for water transportation applications. Based on this, it is believed that the simple method proposed in this paper will pave a new way for producing a sticky superhydrophobic surface and obtain a wide range of use.

  12. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

    Science.gov (United States)

    Thornton, F J; Du, J; Suleiman, S A; Dieter, R; Tefera, G; Pillai, K R; Korosec, F R; Mistretta, C A; Grist, T M

    2006-08-01

    To evaluate a novel time-resolved contrast-enhanced (CE) projection reconstruction (PR) magnetic resonance angiography (MRA) method for identifying potential bypass graft target vessels in patients with Class II-IV peripheral vascular disease. Twenty patients (M:F = 15:5, mean age = 58 years, range = 48-83 years), were recruited from routine MRA referrals. All imaging was performed on a 1.5 T MRI system with fast gradients (Signa LX; GE Healthcare, Waukesha, WI). Images were acquired with a novel technique that combined undersampled PR with a time-resolved acquisition to yield an MRA method with high temporal and spatial resolution. The method is called PR hyper time-resolved imaging of contrast kinetics (PR-hyperTRICKS). Quantitative and qualitative analyses were used to compare two-dimensional (2D) time-of-flight (TOF) and PR-hyperTRICKS in 13 arterial segments per lower extremity. Statistical analysis was performed with the Wilcoxon signed-rank test. Fifteen percent (77/517) of the vessels were scored as missing or nondiagnostic with 2D TOF, but were scored as diagnostic with PR-hyperTRICKS. Image quality was superior with PR-hyperTRICKS vs. 2D TOF (on a four-point scale, mean rank = 3.3 +/- 1.2 vs. 2.9 +/- 1.2, P < 0.0001). PR-hyperTRICKS produced images with high contrast-to-noise ratios (CNR) and high spatial and temporal resolution. 2D TOF images were of inferior quality due to moderate spatial resolution, inferior CNR, greater flow-related artifacts, and absence of temporal resolution. PR-hyperTRICKS provides superior preoperative assessment of lower limb ischemia compared to 2D TOF.

  13. Analysis of a lin-42/period Null Allele Implicates All Three Isoforms in Regulation of Caenorhabditis elegans Molting and Developmental Timing

    Directory of Open Access Journals (Sweden)

    Theresa L. B. Edelman

    2016-12-01

    Full Text Available The Caenorhabditis elegans heterochronic gene pathway regulates the relative timing of events during postembryonic development. lin-42, the worm homolog of the circadian clock gene, period, is a critical element of this pathway. lin-42 function has been defined by a set of hypomorphic alleles that cause precocious phenotypes, in which later developmental events, such as the terminal differentiation of hypodermal cells, occur too early. A subset of alleles also reveals a significant role for lin-42 in molting; larval stages are lengthened and ecdysis often fails in these mutant animals. lin-42 is a complex locus, encoding overlapping and nonoverlapping isoforms. Although existing alleles that affect subsets of isoforms have illuminated important and distinct roles for this gene in developmental timing, molting, and the decision to enter the alternative dauer state, it is essential to have a null allele to understand all of the roles of lin-42 and its individual isoforms. To remedy this problem and discover the null phenotype, we engineered an allele that deletes the entire lin-42 protein-coding region. lin-42 null mutants are homozygously viable, but have more severe phenotypes than observed in previously characterized hypomorphic alleles. We also provide additional evidence for this conclusion by using the null allele as a base for reintroducing different isoforms, showing that each isoform can provide heterochronic and molting pathway activities. Transcript levels of the nonoverlapping isoforms appear to be under coordinate temporal regulation, despite being driven by independent promoters. The lin-42 null allele will continue to be an important tool for dissecting the functions of lin-42 in molting and developmental timing.

  14. Real-time high dynamic range laser scanning microscopy

    Science.gov (United States)

    Vinegoni, C.; Leon Swisher, C.; Fumene Feruglio, P.; Giedt, R. J.; Rousso, D. L.; Stapleton, S.; Weissleder, R.

    2016-04-01

    In conventional confocal/multiphoton fluorescence microscopy, images are typically acquired under ideal settings and after extensive optimization of parameters for a given structure or feature, often resulting in information loss from other image attributes. To overcome the problem of selective data display, we developed a new method that extends the imaging dynamic range in optical microscopy and improves the signal-to-noise ratio. Here we demonstrate how real-time and sequential high dynamic range microscopy facilitates automated three-dimensional neural segmentation. We address reconstruction and segmentation performance on samples with different size, anatomy and complexity. Finally, in vivo real-time high dynamic range imaging is also demonstrated, making the technique particularly relevant for longitudinal imaging in the presence of physiological motion and/or for quantification of in vivo fast tracer kinetics during functional imaging.

  15. Instructional leaders for all? High school science department heads and instructional leadership across all science disciplines

    Science.gov (United States)

    Sanborn, Stephen

    Many high school science departments are responding to changes in state standards with respect to both curricular content and instructional practices. In the typical American high school organization, the academic department head is ideally positioned to influence change in the instructional practices of teachers within the department. Even though science department heads are well situated to provide leadership during this period of transition, the literature has not addressed the question of how well science department heads believe they can provide instructional leadership for all of the teachers in their department, whether they are teaching within and outside of the head's own sub-discipline. Nor is it known how science department heads view the role of pedagogical content knowledge in teaching different science disciplines. Using an online survey comprised of 26 objective questions and one open response question, a 54-respondent sample of science department heads provided no strong consensus regarding their beliefs about the role of pedagogical content knowledge in science instruction. However, science department heads expressed a significant difference in their views about their capacity to provide instructional leadership for teachers sharing their science content area compared to teachers instructing other science content areas. Given wide-spread science education reform efforts introduced in response to the Next Generation Science Standards, these findings may serve to provide some direction for determining how to best support the work of science department heads as they strive to provide instructional leadership for the teachers in their departments.

  16. Completion pancreatectomy and islet cell autotransplantation as salvage therapy for patients failing previous operative interventions for chronic pancreatitis.

    Science.gov (United States)

    Wilson, Gregory C; Sutton, Jeffrey M; Smith, Milton T; Schmulewitz, Nathan; Salehi, Marzieh; Choe, Kyuran A; Levinsky, Nick C; Brunner, John E; Abbott, Daniel E; Sussman, Jeffrey J; Edwards, Michael J; Ahmad, Syed A

    2015-10-01

    Traditional decompressive and/or pancreatic resection procedures have been the cornerstone of operative therapy for refractory abdominal pain secondary to chronic pancreatitis. Management of patients that fail these traditional interventions represents a clinical dilemma. Salvage therapy with completion pancreatectomy and islet cell autotransplantation (CPIAT) is an emerging treatment option for this patient population; however, outcomes after this procedure have not been well-studied. All patients undergoing CPIAT after previous decompressive and/or pancreatic resection for the treatment of chronic pancreatitis at our institution were identified for inclusion in this single-center observational study. Study end points included islet yield, narcotic requirements, glycemic control, and quality of life (QOL). QOL was assessed using the Short Form (SF)-36 health questionnaire. Sixty-four patients underwent CPIAT as salvage therapy. The median age at time of CPIAT was 38 years (interquartile range [IQR], 14.7-65.4). The most common etiology of chronic pancreatitis was idiopathic pancreatitis (66%; n = 42) followed by genetically linked pancreatitis (9%; n = 6) and alcoholic pancreatitis (8%; n = 5). All of these patients had previously undergone prior limited pancreatic resection or decompressive procedure. The majority of patients (50%; n = 32) underwent prior pancreaticoduodenectomy, whereas the remainder had undergone distal pancreatectomy (17%; n = 11), Frey (13%; n = 8), Puestow (13%; n = 8), or Berne (8%; n = 5) procedures. Median time from initial surgical intervention to CPIAT was 28.1 months (IQR, 13.6-43.0). All of these patients underwent a successful CPIAT. Mean operative time was 502.2 minutes with average hospital duration of stay of 13 days. Islet cell isolation was feasible despite previous procedures with a mean islet yield of 331,304 islet cell equivalents, which totaled an islet cell autotransplantation of 4,737 ± 492 IEQ/kg body weight. Median

  17. All solution-processed high-resolution bottom-contact transparent metal-oxide thin film transistors

    International Nuclear Information System (INIS)

    Park, Sung Kyu; Kim, Yong-Hoon; Han, Jeong-In

    2009-01-01

    We report all solution-processed high-resolution bottom-contact indium-gallium-zinc-oxide (IGZO) thin film transistors (TFTs) using a simple surface patterning and dip-casting process. High-resolution nanoparticulate Ag source/drain electrodes and a sol-gel processed IGZO semiconductor were deposited by a simple dip-casting along with a photoresist-free, non-relief-pattern lithographic process. The deposited Ag and IGZO solution can be steered into the desired hydrophilic areas by a low surface energy self-assembled monolayer, resulting in source/drain electrodes and semiconducting layer, respectively. The all solution-processed bottom-contact IGZO TFTs including a channel length of 10 μm typically showed a mobility range 0.05-0.2 cm 2 V -1 s -1 with an on/off ratio of more than 10 6 .

  18. Ensuring High-Quality Learning for All

    Science.gov (United States)

    Núñez, Elsa M.

    2018-01-01

    The Association of American Colleges and Universities (AAC&U) has embarked on a sustained program to enhance the quality of student learning on campuses, while also supporting AAC&U members' efforts to bring liberal education to all sectors of society. This commitment to quality and equity in service to democracy forms the basis for…

  19. Calculation of nonzero-temperature Casimir forces in the time domain

    International Nuclear Information System (INIS)

    Pan, Kai; Reid, M. T. Homer; McCauley, Alexander P.; Rodriguez, Alejandro W.; White, Jacob K.; Johnson, Steven G.

    2011-01-01

    We show how to compute Casimir forces at nonzero temperatures with time-domain electromagnetic simulations, for example, using a finite-difference time-domain (FDTD) method. Compared to our previous zero-temperature time-domain method, only a small modification is required, but we explain that some care is required to properly capture the zero-frequency contribution. We validate the method against analytical and numerical frequency-domain calculations, and show a surprising high-temperature disappearance of a nonmonotonic behavior previously demonstrated in a pistonlike geometry.

  20. 33 CFR 150.531 - How many fire pumps must be kept ready for use at all times?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false How many fire pumps must be kept ready for use at all times? 150.531 Section 150.531 Navigation and Navigable Waters COAST GUARD... Specialty Equipment Miscellaneous Operations § 150.531 How many fire pumps must be kept ready for use at all...

  1. Adolescents' physical activity is associated with previous and current physical activity practice by their parents.

    Science.gov (United States)

    Christofaro, Diego Giulliano Destro; Andersen, Lars Bo; Andrade, Selma Maffei de; Barros, Mauro Virgílio Gomes de; Saraiva, Bruna Thamyres Ciccotti; Fernandes, Rômulo Araújo; Ritti-Dias, Raphael Mendes

    The purpose of this study was to determine whether parents' current and previous physical activity practice is associated with adolescents' physical activity. The sample was composed of 1231 adolescents (14-17 years), and 1202 mothers and 871 fathers were interviewed. Weight and height of the adolescents were measured. Self-reported parents' weight and height were obtained. The current and previous physical activity levels (Baecke's questionnaire) of parents (during childhood and adolescence) and adolescents' physical activity levels were obtained using a questionnaire. The magnitude of the associations between parent and adolescent physical activity levels was determined by binary logistic regression (adjusted by sex, age, and socioeconomic level of adolescents and education level of parents). The current physical activity practice by parents was associated with adolescents' physical activity (p<0.001). The physical activities reported by parents in their childhood and adolescence were also associated with higher physical activity levels among adolescents. Adolescents whose parents were both physically active in the past and present were six times (OR=6.67 [CI=1.94-22.79]) more likely to be physically active compared to adolescents with no parents who were physically active in the past. The current and previous physical activities of parents were associated with higher levels of physical activity in adolescents, even after controlling for confounding factors. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. Time-course of attention for threatening pictures in high and low trait anxiety.

    Science.gov (United States)

    Koster, Ernst H W; Verschuere, Bruno; Crombez, Geert; Van Damme, Stefaan

    2005-08-01

    Cognitive studies about anxiety suggest that the interplay between automatic and strategic biases in attention to threat is related to the persistence of fear. In the present study, the time-course of attention to pictures with varying threat levels was investigated in high trait anxious (HTA, n=21) and low trait anxious (LTA, n=22) students. In a visual probe detection task, high and mild threat pictures were presented at three durations: 100, 500, and 1250 ms. Results indicated that all individuals attended to the high threat pictures for the 100 ms condition. Differential responding between HTA and LTA individuals was found for the 500 ms condition: only HTA individuals showed an attentional bias for mild threatening stimuli. For the 1250 ms condition, the HTA individuals attended away from high and mild threat pictures. The observed pattern of differential attention to threatening pictures may explain the persistence of fear in HTA individuals.

  3. Cubic scattering amplitudes for all massless representations of the Poincare group in any space-time dimension

    International Nuclear Information System (INIS)

    Fradkin, E.S.; Metsaev, R.R.

    1996-02-01

    Using the language of highest weight representations and the light cone formalism we construct a full list of cubic amplitudes of scattering for all bosonic massless representations of the Poincare group in any even space-time dimension. (author). 29 refs

  4. A space-time rainfall generator for highly convective Mediterranean rainstorms

    Directory of Open Access Journals (Sweden)

    S. Salsón

    2003-01-01

    Full Text Available Distributed hydrological models require fine resolution rainfall inputs, enhancing the practical interest of space-time rainfall models, capable of generating through numerical simulation realistic space-time rainfall intensity fields. Among different mathematical approaches, those based on point processes and built upon a convenient analytical description of the raincell as the fundamental unit, have shown to be particularly suitable and well adapted when extreme rainfall events of convective nature are considered. Starting from previous formulations, some analytical refinements have been considered, allowing practical generation of space-time rainfall intensity fields for that type of rainstorm events. Special attention is placed on the analytical description of the spatial and temporal evolution of the rainfall intensities produced by the raincells. After deriving the necessary analytical results, the seven parameters of the model have been estimated by the method of moments, for each of the 30 selected rainfall events in the Jucar River Basin (ValenciaSpain – period 1991 to 2000, using 5-min aggregated rainfall data series from an automatic raingauge network.

  5. Stress in highly demanding IT jobs: transformational leadership moderates the impact of time pressure on exhaustion and work-life balance.

    Science.gov (United States)

    Syrek, Christine J; Apostel, Ella; Antoni, Conny H

    2013-07-01

    The objective of this article is to investigate transformational leadership as a potential moderator of the negative relationship of time pressure to work-life balance and of the positive relationship between time pressure and exhaustion. Recent research regards time pressure as a challenge stressor; while being positively related to motivation and performance, time pressure also increases employee strain and decreases well-being. Building on the Job Demand-Resources model, we hypothesize that transformational leadership moderates the relationships between time pressure and both employees' exhaustion and work-life balance such that both relationships will be weaker when transformational leadership is higher. Of seven information technology organizations in Germany, 262 employees participated in the study. Established scales for time pressure, transformational leadership, work-life balance, and exhaustion were used, all showing good internal consistencies. The results support our assumptions. Specifically, we find that under high transformational leadership the impact of time pressure on exhaustion and work-life balance was less strong. The results of this study suggest that, particularly under high time pressure, transformational leadership is an important factor for both employees' work-life balance and exhaustion. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  6. High-k shallow traps observed by charge pumping with varying discharging times

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Szu-Han; Chen, Ching-En; Tseng, Tseung-Yuen [Department of Electronics Engineering, National Chiao Tung University, Hsinchu 300, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Advanced Optoelectronics Technology Center, National Cheng Kung University, Tainan, Taiwan (China); Lu, Ying-Hsin; Lo, Wen-Hung; Tsai, Jyun-Yu; Liu, Kuan-Ju [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Wang, Bin-Wei; Cao, Xi-Xin [Department of Embedded System Engineering, Peking University, Beijing, P.R.China (China); Chen, Hua-Mao [Department of Photonics and Institute of Electro-Optical Engineering, National Chiao Tung University, Hsinchu, Taiwan (China); Cheng, Osbert; Huang, Cheng-Tung; Chen, Tsai-Fu [Device Department, United Microelectronics Corporation, Tainan Science Park, Taiwan (China)

    2013-11-07

    In this paper, we investigate the influence of falling time and base level time on high-k bulk shallow traps measured by charge pumping technique in n-channel metal-oxide-semiconductor field-effect transistors with HfO{sub 2}/metal gate stacks. N{sub T}-V{sub high} {sub level} characteristic curves with different duty ratios indicate that the electron detrapping time dominates the value of N{sub T} for extra contribution of I{sub cp} traps. N{sub T} is the number of traps, and I{sub cp} is charge pumping current. By fitting discharge formula at different temperatures, the results show that extra contribution of I{sub cp} traps at high voltage are in fact high-k bulk shallow traps. This is also verified through a comparison of different interlayer thicknesses and different Ti{sub x}N{sub 1−x} metal gate concentrations. Next, N{sub T}-V{sub high} {sub level} characteristic curves with different falling times (t{sub falling} {sub time}) and base level times (t{sub base} {sub level}) show that extra contribution of I{sub cp} traps decrease with an increase in t{sub falling} {sub time}. By fitting discharge formula for different t{sub falling} {sub time}, the results show that electrons trapped in high-k bulk shallow traps first discharge to the channel and then to source and drain during t{sub falling} {sub time}. This current cannot be measured by the charge pumping technique. Subsequent measurements of N{sub T} by charge pumping technique at t{sub base} {sub level} reveal a remainder of electrons trapped in high-k bulk shallow traps.

  7. All in its proper time: monitoring the emergence of a memory bias for novel, arousing-negative words in individuals with high and low trait anxiety.

    Science.gov (United States)

    Eden, Annuschka Salima; Zwitserlood, Pienie; Keuper, Katharina; Junghöfer, Markus; Laeger, Inga; Zwanzger, Peter; Dobel, Christian

    2014-01-01

    The well-established memory bias for arousing-negative stimuli seems to be enhanced in high trait-anxious persons and persons suffering from anxiety disorders. We monitored the emergence and development of such a bias during and after learning, in high and low trait anxious participants. A word-learning paradigm was applied, consisting of spoken pseudowords paired either with arousing-negative or neutral pictures. Learning performance during training evidenced a short-lived advantage for arousing-negative associated words, which was not present at the end of training. Cued recall and valence ratings revealed a memory bias for pseudowords that had been paired with arousing-negative pictures, immediately after learning and two weeks later. This held even for items that were not explicitly remembered. High anxious individuals evidenced a stronger memory bias in the cued-recall test, and their ratings were also more negative overall compared to low anxious persons. Both effects were evident, even when explicit recall was controlled for. Regarding the memory bias in anxiety prone persons, explicit memory seems to play a more crucial role than implicit memory. The study stresses the need for several time points of bias measurement during the course of learning and retrieval, as well as the employment of different measures for learning success.

  8. All in its proper time: monitoring the emergence of a memory bias for novel, arousing-negative words in individuals with high and low trait anxiety.

    Directory of Open Access Journals (Sweden)

    Annuschka Salima Eden

    Full Text Available The well-established memory bias for arousing-negative stimuli seems to be enhanced in high trait-anxious persons and persons suffering from anxiety disorders. We monitored the emergence and development of such a bias during and after learning, in high and low trait anxious participants. A word-learning paradigm was applied, consisting of spoken pseudowords paired either with arousing-negative or neutral pictures. Learning performance during training evidenced a short-lived advantage for arousing-negative associated words, which was not present at the end of training. Cued recall and valence ratings revealed a memory bias for pseudowords that had been paired with arousing-negative pictures, immediately after learning and two weeks later. This held even for items that were not explicitly remembered. High anxious individuals evidenced a stronger memory bias in the cued-recall test, and their ratings were also more negative overall compared to low anxious persons. Both effects were evident, even when explicit recall was controlled for. Regarding the memory bias in anxiety prone persons, explicit memory seems to play a more crucial role than implicit memory. The study stresses the need for several time points of bias measurement during the course of learning and retrieval, as well as the employment of different measures for learning success.

  9. All-Optical Signal Processing for 640 Gbit/s Applications

    DEFF Research Database (Denmark)

    Mulvad, Hans Christian Hansen

    2008-01-01

    This thesis concerns all-optical signal processing technologies for ultra-high serial data rates up to 640 Gbit/s. Firstly, time-division add-drop multiplexing at 640 Gbit/s is demonstrated for the first time using two different fibre-based switching techniques. Secondly, a novel principle for po...

  10. Visualization investigation of acoustic and flow-induced vibration in main stream lines using a high-time-resolved PIV technique

    International Nuclear Information System (INIS)

    Li, Yanrong; Someya, Satoshi; Okamoto, Koji

    2009-01-01

    Systems with closed side-branches are liable to an excitation of sound, as called cavity tone. It may occur in pipe branches leading to safety valves or to boiler relief valves. The outbreak mechanism of the cavity tone has been known by phase-averaged measurement in previous researches, while the relation between sound propagation and flow field is still unclear due to the difficulty of detecting instantaneous velocity field. High-time-resolved PIV has a possibility to analyze the velocity field and the relation mentioned above. In this study, flow-induced acoustic resonance of piping system containing closed side-branches was investigated experimentally. A high-time-resolved PIV technique was applied to measure a gas-flow in a cavity. Air flow containing oil mist as tracer particles was measured using a high frequency pulse laser and a high speed camera. The present investigation on the coaxial closed side-branches is the first rudimentary study to visualize the fluid flow two-dimensionally in the cross-section by using PIV and to measure the pressure at the downstream side opening of the cavity by microphone. The fluid flows at different points in the cavity interact with some phase differences and the relation was clarified. (author)

  11. Results of kidney transplantation from high-terminal creatinine donors and the role of time-zero biopsy.

    Science.gov (United States)

    Lin, N C; Yang, A H; King, K L; Wu, T H; Yang, W C; Loong, C C

    2010-11-01

    Deceased-donor kidney transplantation (DDKT) from high-terminal creatinine donors is associated with lower graft survival. These kidneys may be considered for discarding, worsening the organ shortage crisis. Using time-zero biopsy for histologic evaluation of these kidneys, we identified those organs eligible for transplantation, seeking to achieve better graft utility with comparable outcomes. From April 2004 to April 2008, 55 patients underwent DDKT. A time-zero biopsy was used to examine glomerulosclerosis, interstitial fibrosis, tubular atrophy, and arteriolar narrowing. A scoring system was used to determine a discard. Twenty-five patients received DDKT from donors whose terminal creatinine levels were >2.0 mg/dL (high terminal creatinine, HTC group) and 30 from donors whose terminal creatinine levels were creatinine, LTC group). Patients who accepted kidneys from HTC donors had shorter waiting times (P = .011) but a higher incidence of delayed graft function after transplantation (P high-terminal creatinine donors can be transplanted to overcome the organ shortage while achieving reasonable graft survival. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Terahertz polarization converter based on all-dielectric high birefringence metamaterial with elliptical air holes

    KAUST Repository

    Zi, Jianchen

    2018-02-15

    Metamaterials have been widely applied in the polarization conversion of terahertz (THz) waves. However, common plasmonic metamaterials usually work as reflective devices and have low transmissions. All-dielectric metamaterials can overcome these shortcomings. An all-dielectric metamaterial based on silicon with elliptical air holes is reported to achieve high artificial birefringence at THz frequencies. Simulations show that with appropriate structural parameters the birefringence of the dielectric metamaterial can remain flat and is above 0.7 within a broad band. Moreover, the metamaterial can be designed as a broadband quarter wave plate. A sample metamaterial was fabricated and tested to prove the validity of the simulations, and the sample could work as a quarter wave plate at 1.76 THz. The all-dielectric metamaterial that we proposed is of great significance for high performance THz polarization converters.

  13. Dose-response association of moderate-to-vigorous physical activity with cardiovascular biomarkers and all-cause mortality: Considerations by individual sports, exercise and recreational physical activities.

    Science.gov (United States)

    Loprinzi, Paul D

    2015-12-01

    Previous research demonstrates that moderate-to-vigorous physical activity (MVPA) is associated with reduced all-cause mortality risk. Our understanding of whether individual physical activities are associated with all-cause mortality is less understood. Data from the 1999-2006 NHANES were employed, with follow-up through 2011. 48 different individual physical activities (e.g., swimming, running, bicycling) were assessed, and total MVPA MET-min-month was calculated based on their responses to these 48 individual physical activities. Greater engagement in MVPA was associated with more favorable cardiovascular biomarkers, particularly for men. Even after adjustment for total MVPA, different individual physical activities were associated with cardiovascular biomarkers across gender. When compared to those not meeting guidelines (0-1999 MVPA MET-min-month), a dose-response association between MVPA and mortality was observed, with those engaging in 5 times the guideline level having the lowest risk of all-cause mortality (45% reduced risk). There was no evidence of a harmful effect of very high MVPA (e.g., 20,000+ MVPA MET-min-month). Engaging in MVPA even below the minimum recommendation was associated with survival benefits, and the greatest survival effects occurred at a dose of approximately 5 times the minimum recommendation. Although very high levels (e.g., 10 times the minimum recommendation) of self-reported MVPA did not demonstrate the greatest survival effects, high levels of physical activity did not appear to have harmful effects. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pglaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  15. Estimating High-Dimensional Time Series Models

    DEFF Research Database (Denmark)

    Medeiros, Marcelo C.; Mendes, Eduardo F.

    We study the asymptotic properties of the Adaptive LASSO (adaLASSO) in sparse, high-dimensional, linear time-series models. We assume both the number of covariates in the model and candidate variables can increase with the number of observations and the number of candidate variables is, possibly......, larger than the number of observations. We show the adaLASSO consistently chooses the relevant variables as the number of observations increases (model selection consistency), and has the oracle property, even when the errors are non-Gaussian and conditionally heteroskedastic. A simulation study shows...

  16. ATLAS: A High-cadence All-sky Survey System

    Science.gov (United States)

    Tonry, J. L.; Denneau, L.; Heinze, A. N.; Stalder, B.; Smith, K. W.; Smartt, S. J.; Stubbs, C. W.; Weiland, H. J.; Rest, A.

    2018-06-01

    Technology has advanced to the point that it is possible to image the entire sky every night and process the data in real time. The sky is hardly static: many interesting phenomena occur, including variable stationary objects such as stars or QSOs, transient stationary objects such as supernovae or M dwarf flares, and moving objects such as asteroids and the stars themselves. Funded by NASA, we have designed and built a sky survey system for the purpose of finding dangerous near-Earth asteroids (NEAs). This system, the “Asteroid Terrestrial-impact Last Alert System” (ATLAS), has been optimized to produce the best survey capability per unit cost, and therefore is an efficient and competitive system for finding potentially hazardous asteroids (PHAs) but also for tracking variables and finding transients. While carrying out its NASA mission, ATLAS now discovers more bright (m day cadence. ATLAS discovered the afterglow of a gamma-ray burst independent of the high energy trigger and has released a variable star catalog of 5 × 106 sources. This is the first of a series of articles describing ATLAS, devoted to the design and performance of the ATLAS system. Subsequent articles will describe in more detail the software, the survey strategy, ATLAS-derived NEA population statistics, transient detections, and the first data release of variable stars and transient light curves.

  17. Improved Resolution Optical Time Stretch Imaging Based on High Efficiency In-Fiber Diffraction.

    Science.gov (United States)

    Wang, Guoqing; Yan, Zhijun; Yang, Lei; Zhang, Lin; Wang, Chao

    2018-01-12

    Most overlooked challenges in ultrafast optical time stretch imaging (OTSI) are sacrificed spatial resolution and higher optical loss. These challenges are originated from optical diffraction devices used in OTSI, which encode image into spectra of ultrashort optical pulses. Conventional free-space diffraction gratings, as widely used in existing OTSI systems, suffer from several inherent drawbacks: limited diffraction efficiency in a non-Littrow configuration due to inherent zeroth-order reflection, high coupling loss between free-space gratings and optical fibers, bulky footprint, and more importantly, sacrificed imaging resolution due to non-full-aperture illumination for individual wavelengths. Here we report resolution-improved and diffraction-efficient OTSI using in-fiber diffraction for the first time to our knowledge. The key to overcome the existing challenges is a 45° tilted fiber grating (TFG), which serves as a compact in-fiber diffraction device offering improved diffraction efficiency (up to 97%), inherent compatibility with optical fibers, and improved imaging resolution owning to almost full-aperture illumination for all illumination wavelengths. 50 million frames per second imaging of fast moving object at 46 m/s with improved imaging resolution has been demonstrated. This conceptually new in-fiber diffraction design opens the way towards cost-effective, compact and high-resolution OTSI systems for image-based high-throughput detection and measurement.

  18. Constant time distance queries in planar unweighted graphs with subquadratic preprocessing time

    DEFF Research Database (Denmark)

    Wulff-Nilsen, C.

    2013-01-01

    Let G be an n-vertex planar, undirected, and unweighted graph. It was stated as open problems whether the Wiener index, defined as the sum of all-pairs shortest path distances, and the diameter of G can be computed in o(n(2)) time. We show that both problems can be solved in O(n(2) log log n/log n......) time with O(n) space. The techniques that we apply allow us to build, within the same time bound, an oracle for exact distance queries in G. More generally, for any parameter S is an element of [(log n/log log n)(2), n(2/5)], distance queries can be answered in O (root S log S/log n) time per query...... with O(n(2)/root S) preprocessing time and space requirement. With respect to running time, this is better than previous algorithms when log S = o(log n). All algorithms have linear space requirement. Our results generalize to a larger class of graphs including those with a fixed excluded minor. (C) 2012...

  19. CMOS continuous-time adaptive equalizers for high-speed serial links

    CERN Document Server

    Gimeno Gasca, Cecilia; Aldea Chagoyen, Concepción

    2015-01-01

    This book introduces readers to the design of adaptive equalization solutions integrated in standard CMOS technology for high-speed serial links. Since continuous-time equalizers offer various advantages as an alternative to discrete-time equalizers at multi-gigabit rates, this book provides a detailed description of continuous-time adaptive equalizers design - both at transistor and system levels-, their main characteristics and performances. The authors begin with a complete review and analysis of the state of the art of equalizers for wireline applications, describing why they are necessary, their types, and their main applications. Next, theoretical fundamentals of continuous-time adaptive equalizers are explored. Then, new structures are proposed to implement the different building blocks of the adaptive equalizer: line equalizer, loop-filters, power comparator, etc.  The authors demonstrate the design of a complete low-power, low-voltage, high-speed, continuous-time adaptive equalizer. Finally, a cost-...

  20. A Pilot Study of Hypofractionated Stereotactic Radiation Therapy and Sunitinib in Previously Irradiated Patients With Recurrent High-Grade Glioma

    International Nuclear Information System (INIS)

    Wuthrick, Evan J.; Curran, Walter J.; Camphausen, Kevin; Lin, Alexander; Glass, Jon; Evans, James; Andrews, David W.; Axelrod, Rita; Shi, Wenyin; Werner-Wasik, Maria; Haacke, E. Mark; Hillman, Gilda G.; Dicker, Adam P.

    2014-01-01

    Purpose/Objective(s): Angiogenic blockade with irradiation may enhance the therapeutic ratio of radiation therapy (RT) through vascular normalization. We sought to determine the safety and toxicity profile of continuous daily-dosed sunitinib when combined with hypofractionated stereotactic RT (fSRT) for recurrent high-grade gliomas (rHGG). Methods and Materials: Eligible patients had malignant high-grade glioma that recurred or progressed after primary surgery and RT. All patients received a minimum of a 10-day course of fSRT, had World Health Organization performance status of 0 to 1, and a life expectancy of >3 months. During fSRT, sunitinib was administered at 37.5 mg daily. The primary endpoint was acute toxicity, and response was assessed via serial magnetic resonance imaging. Results: Eleven patients with rHGG were enrolled. The fSRT doses delivered ranged from 30 to 42 Gy in 2.5- to 3.75-Gy fractions. The median follow-up time was 40 months. Common acute toxicities included hematologic disorders, fatigue, hypertension, and elevated liver transaminases. Sunitinib and fSRT were well tolerated. One grade 4 mucositis toxicity occurred, and no grade 4 or 5 hypertensive events or intracerebral hemorrhages occurred. One patient had a nearly complete response, and 4 patients had stable disease for >9 months. Two patients (18%) remain alive and progression-free >3 years from enrollment. The 6-month progression-free survival was 45%. Conclusions: Sunitinib at a daily dose of 37.5 mg given concurrently with hypofractionated stereotactic reirradiation for rHGG yields acceptable toxicities and an encouraging 6-month progression-free survival

  1. A Pilot Study of Hypofractionated Stereotactic Radiation Therapy and Sunitinib in Previously Irradiated Patients With Recurrent High-Grade Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Wuthrick, Evan J., E-mail: evan.wuthrick@osumc.edu [Department of Radiation Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Curran, Walter J. [Department of Radiation Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Camphausen, Kevin [Department of Radiation Oncology Branch, National Cancer Institute, Bethesda, Maryland (United States); Lin, Alexander [Department of Radiation Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Glass, Jon; Evans, James; Andrews, David W. [Department of Neurological Surgery, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Axelrod, Rita [Department of Medical Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Shi, Wenyin; Werner-Wasik, Maria [Department of Radiation Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States); Haacke, E. Mark [Department of Radiology, Barbara Ann Karmanos Cancer Institute, Wayne State University School of Medicine, Detroit, Michigan (United States); Department of Biomedical Engineering, Barbara Ann Karmanos Cancer Institute, Wayne State University School of Medicine, Detroit, Michigan (United States); Hillman, Gilda G. [Department of Radiation Oncology, Barbara Ann Karmanos Cancer Institute, Wayne State University School of Medicine, Detroit, Michigan (United States); Dicker, Adam P. [Department of Radiation Oncology, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania (United States)

    2014-10-01

    Purpose/Objective(s): Angiogenic blockade with irradiation may enhance the therapeutic ratio of radiation therapy (RT) through vascular normalization. We sought to determine the safety and toxicity profile of continuous daily-dosed sunitinib when combined with hypofractionated stereotactic RT (fSRT) for recurrent high-grade gliomas (rHGG). Methods and Materials: Eligible patients had malignant high-grade glioma that recurred or progressed after primary surgery and RT. All patients received a minimum of a 10-day course of fSRT, had World Health Organization performance status of 0 to 1, and a life expectancy of >3 months. During fSRT, sunitinib was administered at 37.5 mg daily. The primary endpoint was acute toxicity, and response was assessed via serial magnetic resonance imaging. Results: Eleven patients with rHGG were enrolled. The fSRT doses delivered ranged from 30 to 42 Gy in 2.5- to 3.75-Gy fractions. The median follow-up time was 40 months. Common acute toxicities included hematologic disorders, fatigue, hypertension, and elevated liver transaminases. Sunitinib and fSRT were well tolerated. One grade 4 mucositis toxicity occurred, and no grade 4 or 5 hypertensive events or intracerebral hemorrhages occurred. One patient had a nearly complete response, and 4 patients had stable disease for >9 months. Two patients (18%) remain alive and progression-free >3 years from enrollment. The 6-month progression-free survival was 45%. Conclusions: Sunitinib at a daily dose of 37.5 mg given concurrently with hypofractionated stereotactic reirradiation for rHGG yields acceptable toxicities and an encouraging 6-month progression-free survival.

  2. High Energy, Single-Mode, All-Solid-State and Tunable UV Laser Transmitter

    Science.gov (United States)

    Prasad, Narasimha S.; Singh, Upendra N.; Hovis, FLoyd

    2007-01-01

    A high energy, single mode, all solid-state Nd:YAG laser primarily for pumping an UV converter is developed. Greater than 1 J/pulse at 50 HZ PRF and pulse widths around 22 ns have been demonstrated. Higher energy, greater efficiency may be possible. Refinements are known and practical to implement. Technology Demonstration of a highly efficient, high-pulse-energy, single mode UV wavelength generation using flash lamp pumped laser has been achieved. Greater than 90% pump depletion is observed. 190 mJ extra-cavity SFG; IR to UV efficiency > 21% (> 27% for 1 mJ seed). 160 mJ intra-cavity SFG; IR to UV efficiency up to 24% Fluence laser is being refined to match or exceed the above UV converter results. Currently the Nd:YAG pump laser development is a technology demonstration. System can be engineered for compact packaging.

  3. Six weeks of aerobic dance exercise improves blood oxidative stress status and increases interleukin-2 in previously sedentary women.

    Science.gov (United States)

    Leelarungrayub, Donrawee; Saidee, Kunteera; Pothongsunun, Prapas; Pratanaphon, Sainetee; YanKai, Araya; Bloomer, Richard J

    2011-07-01

    This study evaluated the change in blood oxidative stress, blood interleukin-2, and physical performance following 6 weeks of moderate intensity and duration aerobic dance exercise in 24 sedentary women. Blood samples were collected at rest twice before (baseline) and after the 6-week intervention for analysis of protein hydroperoxide (PrOOH), malondialdehyde (MDA), total anti-oxidant capacity (TAC), and interleukin-2 (IL-2) levels. Maximal treadmill run time (Time(max)) and maximal oxygen consumption (VO(2max)) were also measured. All variables were statistically analyzed with a repeated measurement ANOVA and Tukey post hoc. No differences were noted in any variable during the baseline period (p > 0.05). After aerobic dance exercise, VO(2max), Time(max), TAC and IL-2 were significantly increased, whereas MDA levels were decreased significantly (p exercise. It can be concluded that aerobic dance exercise at a moderate intensity and duration can improve physical fitness, decrease MDA, and increase TAC and IL-2 in previously sedentary women. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Previous induced abortion among young women seeking abortion-related care in Kenya: a cross-sectional analysis.

    Science.gov (United States)

    Kabiru, Caroline W; Ushie, Boniface A; Mutua, Michael M; Izugbara, Chimaraoke O

    2016-05-14

    Unsafe abortion is a leading cause of death among young women aged 10-24 years in sub-Saharan Africa. Although having multiple induced abortions may exacerbate the risk for poor health outcomes, there has been minimal research on young women in this region who have multiple induced abortions. The objective of this study was therefore to assess the prevalence and correlates of reporting a previous induced abortion among young females aged 12-24 years seeking abortion-related care in Kenya. We used data on 1,378 young women aged 12-24 years who presented for abortion-related care in 246 health facilities in a nationwide survey conducted in 2012. Socio-demographic characteristics, reproductive and clinical histories, and physical examination assessment data were collected from women during a one-month data collection period using an abortion case capture form. Nine percent (n = 98) of young women reported a previous induced abortion prior to the index pregnancy for which they were receiving care. Statistically significant differences by previous history of induced abortion were observed for area of residence, religion and occupation at bivariate level. Urban dwellers and unemployed/other young women were more likely to report a previous induced abortion. A greater proportion of young women reporting a previous induced abortion stated that they were using a contraceptive method at the time of the index pregnancy (47 %) compared with those reporting no previous induced abortion (23 %). Not surprisingly, a greater proportion of young women reporting a previous induced abortion (82 %) reported their index pregnancy as unintended (not wanted at all or mistimed) compared with women reporting no previous induced abortion (64 %). Our study results show that about one in every ten young women seeking abortion-related care in Kenya reports a previous induced abortion. Comprehensive post-abortion care services targeting young women are needed. In particular, post

  5. High energy resolution and first time-dependent positron annihilation induced Auger electron spectroscopty

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Jakob

    2010-04-03

    It was the aim of this thesis to improve the existing positron annihilation induced Auger spectrometer at the highly intense positron source NEPOMUC (NEutron induced POsitron source MUniCh) in several ways: Firstly, the measurement time for a single spectrum should be reduced from typically 12 h to roughly 1 h or even less. Secondly, the energy resolution, which amounted to {delta}E/E{approx}10%, should be increased by at least one order of magnitude in order to make high resolution positron annihilation induced Auger spectroscopy (PAES)-measurements of Auger transitions possible and thus deliver more information about the nature of the Auger process. In order to achieve these objectives, the PAES spectrometer was equipped with a new electron energy analyzer. For its ideal operation all other components of the Auger analysis chamber had to be adapted. Particularly the sample manipulation and the positron beam guidance had to be renewed. Simulations with SIMION {sup registered} ensured the optimal positron lens parameters. After the adjustment of the new analyzer and its components, first measurements illustrated the improved performance of the PAES setup: Firstly, the measurement time for short overview measurements was reduced from 3 h to 420 s. The measurement time for more detailed Auger spectra was shortened from 12 h to 80 min. Secondly, even with the reduced measurement time, the signal to noise ratio was also enhanced by one order of magnitude. Finally, the energy resolution was improved to {delta}E/E < 1. The exceptional surface sensitivity and elemental selectivity of PAES was demonstrated in measurements of Pd and Fe, both coated with Cu layers of varying thickness. PAES showed that with 0.96 monolayer of Cu on Fe, more than 55% of the detected Auger electrons stem from Cu. In the case of the Cu coated Pd sample 0.96 monolayer of Cu resulted in a Cu Auger fraction of more than 30% with PAES and less than 5% with electron induced Auger spectroscopy

  6. High Titers of Chlamydia trachomatis Antibodies in Brazilian Women with Tubal Occlusion or Previous Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    A. C. S. Machado

    2007-01-01

    Full Text Available Objective. To evaluate serum chlamydia antibody titers (CATs in tubal occlusion or previous ectopic pregnancy and the associated risk factors. Methods. The study population consisted of 55 women wih tubal damage and 55 parous women. CAT was measured using the whole-cell inclusion immunofluorescence test and cervical chlamydial DNA detected by PCR. Odds ratios were calculated to assess variables associated with C. trachomatis infection. Results. The prevalence of chlamydial antibodies and antibody titers in women with tubal occlusion or previous ectopic pregnancy was significantly higher (P<.01 than in parous women. Stepwise logistic regression analysis showed that chlamydia IgG antibodies were associated with tubal damage and with a larger number of lifetime sexual partners. Conclusions. Chlamydia antibody titers were associated with tubal occlusion, prior ectopic pregnancy, and with sexual behavior, suggesting that a chlamydia infection was the major contributor to the tubal damage in these women.

  7. Is high-intensity interval training a time-efficient exercise strategy to improve health and fitness?

    Science.gov (United States)

    Gillen, Jenna B; Gibala, Martin J

    2014-03-01

    Growing research suggests that high-intensity interval training (HIIT) is a time-efficient exercise strategy to improve cardiorespiratory and metabolic health. "All out" HIIT models such as Wingate-type exercise are particularly effective, but this type of training may not be safe, tolerable or practical for many individuals. Recent studies, however, have revealed the potential for other models of HIIT, which may be more feasible but are still time-efficient, to stimulate adaptations similar to more demanding low-volume HIIT models and high-volume endurance-type training. As little as 3 HIIT sessions per week, involving ≤10 min of intense exercise within a time commitment of ≤30 min per session, including warm-up, recovery between intervals and cool down, has been shown to improve aerobic capacity, skeletal muscle oxidative capacity, exercise tolerance and markers of disease risk after only a few weeks in both healthy individuals and people with cardiometabolic disorders. Additional research is warranted, as studies conducted have been relatively short-term, with a limited number of measurements performed on small groups of subjects. However, given that "lack of time" remains one of the most commonly cited barriers to regular exercise participation, low-volume HIIT is a time-efficient exercise strategy that warrants consideration by health practitioners and fitness professionals.

  8. High-resolution time-resolved Experiments on mixing and entrainment of buoyant jets in stratified environments

    Energy Technology Data Exchange (ETDEWEB)

    Manera, Annalisa; Bardet, Philippe; Petrov, Victor

    2018-03-29

    , complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

  9. Investigation of previously derived Hyades, Coma, and M67 reddenings

    International Nuclear Information System (INIS)

    Taylor, B.J.

    1980-01-01

    New Hyades polarimetry and field star photometry have been obtained to check the Hyades reddening, which was found to be nonzero in a previous paper. The new Hyades polarimetry implies essentially zero reddening; this is also true of polarimetry published by Behr (which was incorrectly interpreted in the previous paper). Four photometric techniques which are presumed to be insensitive to blanketing are used to compare the Hyades to nearby field stars; these four techniques also yield essentially zero reddening. When all of these results are combined with others which the author has previously published and a simultaneous solution for the Hyades, Coma, and M67 reddenings is made, the results are E (B-V) =3 +- 2 (sigma) mmag, -1 +- 3 (sigma) mmag, and 46 +- 6 (sigma) mmag, respectively. No support for a nonzero Hyades reddening is offered by the new results. When the newly obtained reddenings for the Hyades, Coma, and M67 are compared with results from techniques given by Crawford and by users of the David Dunlap Observatory photometric system, no differences between the new and other reddenings are found which are larger than about 2 sigma. The author had previously found that the M67 main-sequence stars have about the same blanketing as that of Coma and less blanketing than the Hyades; this conclusion is essentially unchanged by the revised reddenings

  10. Is Previous Respiratory Disease a Risk Factor for Lung Cancer?

    Science.gov (United States)

    Denholm, Rachel; Schüz, Joachim; Straif, Kurt; Stücker, Isabelle; Jöckel, Karl-Heinz; Brenner, Darren R.; De Matteis, Sara; Boffetta, Paolo; Guida, Florence; Brüske, Irene; Wichmann, Heinz-Erich; Landi, Maria Teresa; Caporaso, Neil; Siemiatycki, Jack; Ahrens, Wolfgang; Pohlabeln, Hermann; Zaridze, David; Field, John K.; McLaughlin, John; Demers, Paul; Szeszenia-Dabrowska, Neonila; Lissowska, Jolanta; Rudnai, Peter; Fabianova, Eleonora; Dumitru, Rodica Stanescu; Bencko, Vladimir; Foretova, Lenka; Janout, Vladimir; Kendzia, Benjamin; Peters, Susan; Behrens, Thomas; Vermeulen, Roel; Brüning, Thomas; Kromhout, Hans

    2014-01-01

    Rationale: Previous respiratory diseases have been associated with increased risk of lung cancer. Respiratory conditions often co-occur and few studies have investigated multiple conditions simultaneously. Objectives: Investigate lung cancer risk associated with chronic bronchitis, emphysema, tuberculosis, pneumonia, and asthma. Methods: The SYNERGY project pooled information on previous respiratory diseases from 12,739 case subjects and 14,945 control subjects from 7 case–control studies conducted in Europe and Canada. Multivariate logistic regression models were used to investigate the relationship between individual diseases adjusting for co-occurring conditions, and patterns of respiratory disease diagnoses and lung cancer. Analyses were stratified by sex, and adjusted for age, center, ever-employed in a high-risk occupation, education, smoking status, cigarette pack-years, and time since quitting smoking. Measurements and Main Results: Chronic bronchitis and emphysema were positively associated with lung cancer, after accounting for other respiratory diseases and smoking (e.g., in men: odds ratio [OR], 1.33; 95% confidence interval [CI], 1.20–1.48 and OR, 1.50; 95% CI, 1.21–1.87, respectively). A positive relationship was observed between lung cancer and pneumonia diagnosed 2 years or less before lung cancer (OR, 3.31; 95% CI, 2.33–4.70 for men), but not longer. Co-occurrence of chronic bronchitis and emphysema and/or pneumonia had a stronger positive association with lung cancer than chronic bronchitis “only.” Asthma had an inverse association with lung cancer, the association being stronger with an asthma diagnosis 5 years or more before lung cancer compared with shorter. Conclusions: Findings from this large international case–control consortium indicate that after accounting for co-occurring respiratory diseases, chronic bronchitis and emphysema continue to have a positive association with lung cancer. PMID:25054566

  11. Investigation of the delay time distribution of high power microwave surface flashover

    Science.gov (United States)

    Foster, J.; Krompholz, H.; Neuber, A.

    2011-01-01

    Characterizing and modeling the statistics associated with the initiation of gas breakdown has proven to be difficult due to a variety of rather unexplored phenomena involved. Experimental conditions for high power microwave window breakdown for pressures on the order of 100 to several 100 torr are complex: there are little to no naturally occurring free electrons in the breakdown region. The initial electron generation rate, from an external source, for example, is time dependent and so is the charge carrier amplification in the increasing radio frequency (RF) field amplitude with a rise time of 50 ns, which can be on the same order as the breakdown delay time. The probability of reaching a critical electron density within a given time period is composed of the statistical waiting time for the appearance of initiating electrons in the high-field region and the build-up of an avalanche with an inherent statistical distribution of the electron number. High power microwave breakdown and its delay time is of critical importance, since it limits the transmission through necessary windows, especially for high power, high altitude, low pressure applications. The delay time distribution of pulsed high power microwave surface flashover has been examined for nitrogen and argon as test gases for pressures ranging from 60 to 400 torr, with and without external UV illumination. A model has been developed for predicting the discharge delay time for these conditions. The results provide indications that field induced electron generation, other than standard field emission, plays a dominant role, which might be valid for other gas discharge types as well.

  12. ESHOL study reanalysis: All-cause mortality considered by competing risks and time-dependent covariates for renal transplantation

    Directory of Open Access Journals (Sweden)

    Francisco Maduell

    2016-03-01

    Conclusion: The results of this analysis of the ESHOL trial confirm that post-dilution OL-HDF reduces all-cause mortality versus hemodialysis in prevalent patients. The original results of the ESHOL study, which censored patients discontinuing the study for any reason, were confirmed in the present ITT population without censures and when all-cause mortality was considered by time-dependent and competing risks for transplantation.

  13. It's all in the timing: modeling isovolumic contraction through development and disease with a dynamic dual electromechanical bioreactor system.

    Science.gov (United States)

    Morgan, Kathy Ye; Black, Lauren Deems

    2014-01-01

    This commentary discusses the rationale behind our recently reported work entitled "Mimicking isovolumic contraction with combined electromechanical stimulation improves the development of engineered cardiac constructs," introduces new data supporting our hypothesis, and discusses future applications of our bioreactor system. The ability to stimulate engineered cardiac tissue in a bioreactor system that combines both electrical and mechanical stimulation offers a unique opportunity to simulate the appropriate dynamics between stretch and contraction and model isovolumic contraction in vitro. Our previous study demonstrated that combined electromechanical stimulation that simulated the timing of isovolumic contraction in healthy tissue improved force generation via increased contractile and calcium handling protein expression and improved hypertrophic pathway activation. In new data presented here, we further demonstrate that modification of the timing between electrical and mechanical stimulation to mimic a non-physiological process negatively impacts the functionality of the engineered constructs. We close by exploring the various disease states that have altered timing between the electrical and mechanical stimulation signals as potential future directions for the use of this system.

  14. The STiC ASIC. High precision timing with silicon photomultipliers

    International Nuclear Information System (INIS)

    Harion, Tobias

    2015-01-01

    In recent years, Silicon Photomultipliers are being increasingly used for Time of Flight measurements in particle detectors. To utilize the high intrinsic time resolution of these sensors in detector systems, the development of specialized, highly integrated readout electronics is required. In this thesis, a mixed-signal application specific integrated circuit, named STiC, has been developed, characterized and integrated in a detector system. STiC has been specifically designed for high precision timing measurements with SiPMs, and is in particular dedicated to the EndoTOFPET-US project, which aims to achieve a coincidence time resolution of 200 ps FWHM and an energy resolution of less than 20% in an endoscopic positron emission tomography system. The chip integrates 64 high precision readout channels for SiPMs together with a digital core logic to process, store and transfer the recorded events to a data acquisition system. The performance of the chip has been validated in coincidence measurements using detector modules consisting of 3.1 x 3.1 x 15 mm 3 LYSO crystals coupled to Silicon Photomultipliers from Hamamatsu. The measurements show an energy resolution of 15% FWHM for the detection of 511 keV photons. A coincidence time resolution of 213 ps FWHM has been measured, which is among the best resolution values achieved to date with this detector topology. STiC has been integrated in the EndoTOFPET-US detector system and has been chosen as the baseline design for the readout of SiPM sensors in the Mu3e experiment.

  15. Does previous use affect litter box appeal in multi-cat households?

    Science.gov (United States)

    Ellis, J J; McGowan, R T S; Martin, F

    2017-08-01

    It is commonly assumed that cats actively avoid eliminated materials (especially in multi-cat homes), suggesting regular litter box cleaning as the best defense against out-of-box elimination. The relationship between previous use and litter box appeal to familiar subsequent users is currently unknown. The purpose of this study was to investigate the relationship between previous litter box use and the identity of the previous user, type of elimination, odor, and presence of physical/visual obstructions in a multi-cat household scenario. Cats preferred a clean litter box to a dirty one, but the identity of the previous user had no impact on preferences. While the presence of odor from urine and/or feces did not impact litter box preferences, the presence of odorless faux-urine and/or feces did - with the presence of faux-feces being preferred over faux-urine. Results suggest neither malodor nor chemical communication play a role in litter box preferences, and instead emphasize the importance of regular removal of physical/visual obstructions as the key factor in promoting proper litter box use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. High-level synthesis for reduction of WCET in real-time systems

    DEFF Research Database (Denmark)

    Kristensen, Andreas Toftegaard; Pezzarossa, Luca; Sparsø, Jens

    2017-01-01

    . Compared to executing the high-level language code on a processor, HLS can be used to create hardware that accelerates critical parts of the code. When discussing performance in the context or real-time systems, it is the worst-case execution time (WCET) of a task that matters. WCET obviously benefits from...... hardware acceleration, but it may also benefit from a tighter bound on the WCET. This paper explores the use of and integration of accelerators generated using HLS into a time-predictable processor intended for real-time systems. The high-level design tool, Vivado HLS, is used to generate hardware...

  17. Outcome of the use of tension-free vaginal tape in women with mixed urinary incontinence, previous failed surgery, or low valsalva pressure.

    Science.gov (United States)

    Abdel-Hady, El-Said; Constantine, Glyn

    2005-02-01

    To assess the safety and efficacy of the use of tension-free vaginal tape (TVT) for the treatment of stress urinary incontinence (SUI) in women with mixed incontinence, previous failed incontinence surgery or low valsalva leak point pressure (VLPP). Six hundred and fifty-eight women with SUI underwent the TVT procedure. These included women with mixed stress and urge incontinence (n=128), previous surgery for SUI (n=118), low VLPP (n=80), and those over 70 years old (n=68). The procedure was carried out under spinal anesthetic and operative and immediate postoperative data was collected for all women. Six-month follow-up data was available on 454 women, with the first 300 women completing a quality of life (QOL) questionnaire before and after surgery. The overall subjective cure rate at 6 months was 91%, with 8% of women reporting significant (>50%) improvement in their symptoms. Subgroups with a body mass index > 30, age > 70 years, coexisting instability, previous failed surgery, and low VLPP showed cure rates of 81-89%. QOL improvements for all groups were highly significant. Significant complications included voiding difficulties in 29 women (4.4%), retropubic hematomas in four (0.6%), and thromboembolic episodes in three (0.5%). The simplicity and high efficacy of the TVT makes it the first choice for the treatment of women with SUI, including those with more complex problems or coexisting risk factors.

  18. Deep Reactive Ion Etching (DRIE) of High Aspect Ratio SiC Microstructures using a Time-Multiplexed Etch-Passivate Process

    Science.gov (United States)

    Evans, Laura J.; Beheim, Glenn M.

    2006-01-01

    High aspect ratio silicon carbide (SiC) microstructures are needed for microengines and other harsh environment micro-electro-mechanical systems (MEMS). Previously, deep reactive ion etching (DRIE) of low aspect ratio (AR less than or = 1) deep (greater than 100 micron) trenches in SiC has been reported. However, existing DRIE processes for SiC are not well-suited for definition of high aspect ratio features because such simple etch-only processes provide insufficient control over sidewall roughness and slope. Therefore, we have investigated the use of a time-multiplexed etch-passivate (TMEP) process, which alternates etching with polymer passivation of the etch sidewalls. An optimized TMEP process was used to etch high aspect ratio (AR greater than 5) deep (less than 100 micron) trenches in 6H-SiC. Power MEMS structures (micro turbine blades) in 6H-SiC were also fabricated.

  19. Time-resolved energy spectrum of a pseudospark-produced high-brightness electron beam

    International Nuclear Information System (INIS)

    Myers, T.J.; Ding, B.N.; Rhee, M.J.

    1992-01-01

    The pseudospark, a fast low-pressure gas discharge between a hollow cathode and a planar anode, is found to be an interesting high-brightness electron beam source. Typically, all electron beam produced in the pseudospark has the peak current of ∼1 kA, pulse duration of ∼50 ns, and effective emittance of ∼100 mm-mrad. The energy information of this electron beam, however, is least understood due to the difficulty of measuring a high-current-density beam that is partially space-charge neutralized by the background ions produced in the gas. In this paper, an experimental study of the time-resolved energy spectrum is presented. The pseudospark produced electron beam is injected into a vacuum through a small pinhole so that the electrons without background ions follow single particle motion; the beam is sent through a negative biased electrode and the only portion of beam whose energy is greater than the bias voltage can pass through the electrode and the current is measured by a Faraday cup. The Faraday cup signals with various bias voltage are recorded in a digital oscilloscope. The recorded waveforms are then numerically analyzed to construct a time-resolved energy spectrum. Preliminary results are presented

  20. Effects of full-time and part-time high-ability programs on developments in students’ achievement emotions

    NARCIS (Netherlands)

    Hornstra, L.; van der Veen, I.; Peetsma, T.

    2017-01-01

    This study focused on effects of high-ability programs on students’ achievement emotions, i.e. emotions that students experience that are associated with achievement activities. Participants were students in grade 4–6 of primary education: 218 students attended full-time high-ability programs, 245

  1. High-resolution near real-time drought monitoring in South Asia

    OpenAIRE

    Aadhar, Saran; Mishra, Vimal

    2017-01-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning, and management of water resources at sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. We develop a high-resolution (0.05°) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to m...

  2. Hidden discriminative features extraction for supervised high-order time series modeling.

    Science.gov (United States)

    Nguyen, Ngoc Anh Thi; Yang, Hyung-Jeong; Kim, Sunhee

    2016-11-01

    In this paper, an orthogonal Tucker-decomposition-based extraction of high-order discriminative subspaces from a tensor-based time series data structure is presented, named as Tensor Discriminative Feature Extraction (TDFE). TDFE relies on the employment of category information for the maximization of the between-class scatter and the minimization of the within-class scatter to extract optimal hidden discriminative feature subspaces that are simultaneously spanned by every modality for supervised tensor modeling. In this context, the proposed tensor-decomposition method provides the following benefits: i) reduces dimensionality while robustly mining the underlying discriminative features, ii) results in effective interpretable features that lead to an improved classification and visualization, and iii) reduces the processing time during the training stage and the filtering of the projection by solving the generalized eigenvalue issue at each alternation step. Two real third-order tensor-structures of time series datasets (an epilepsy electroencephalogram (EEG) that is modeled as channel×frequency bin×time frame and a microarray data that is modeled as gene×sample×time) were used for the evaluation of the TDFE. The experiment results corroborate the advantages of the proposed method with averages of 98.26% and 89.63% for the classification accuracies of the epilepsy dataset and the microarray dataset, respectively. These performance averages represent an improvement on those of the matrix-based algorithms and recent tensor-based, discriminant-decomposition approaches; this is especially the case considering the small number of samples that are used in practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Self-reported previous knee injury and low knee function increase knee injury risk in adolescent female football

    DEFF Research Database (Denmark)

    Clausen, Mikkel Bek; Tang, L; Zebis, M K

    2016-01-01

    with low KOOS subscale scores (Sport/Recreational (RR: 2.2) and Quality of Life (RR: 3.0) (P time-loss knee...... questionnaires were collected at baseline. Time-loss knee injuries and football exposures were reported weekly by answers to standardized text-message questions, followed by injury telephone interviews. A priori, self-reported previous knee injury and low KOOS subscale scores (... as independent variables in the risk factor analyses. The study showed that self-reported previous knee injury significantly increased the risk of time-loss knee injury [relative risk (RR): 3.65, 95% confidence (CI) 1.73-7.68; P time-loss knee injury was also significantly increased in players...

  4. Working hours and all-cause mortality in relation to the EU Working Time Directive: a Danish cohort study.

    Science.gov (United States)

    Hannerz, Harald; Soll-Johanning, Helle

    2018-03-12

    In keeping with the need to protect the safety and health of workers, the EU Working Time Directive stipulates that a worker's average working time for each 7-day period, including overtime, does not exceed 48 h. It has, however, not been settled whether or not the threshold at 48 working hours a week is low enough to protect against excess mortality from long work weeks. The aim of the present study was to examine all-cause mortality in relation to weekly working hours among employees in the general population of Denmark. A special attention was given to mortality rates among employees with moderately long work weeks, 41-48 h. Interview data from cohorts of 20-64 year-old employees were drawn from the Danish Labour Force Survey. The participants (N = 159 933) were followed through national registers from the end of the calendar year of the interview (1999-2013) until the end of 2014. Rate ratios (RRs) for all-cause mortality were estimated as a function of weekly working hours while controlling for age, sex, social class, night-time work and calendar year. We found 3374 deaths during an average follow-up time of 7.7 years. With 32-40 working hours a week as reference, the RRs for all-cause mortality were 0.75 (95% CI: 0.66-0.85) for 41-48 and 0.92 (0.80-1.05) for >48 h. Mortality rates in Denmark are significantly lower among employees with moderately long work weeks than they are among full-time employees without overtime work.

  5. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    Science.gov (United States)

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  6. An all-optical fiber optic photoacoustic transducer

    Science.gov (United States)

    Thathachary, Supriya V.; Motameni, Cameron; Ashkenazi, Shai

    2018-02-01

    A highly sensitive fiber-optic Fabry-Perot photoacoustic transducer is proposed in this work. The transducer will consist of separate transmit and receive fibers. The receiver will be composed of a Fabry-Perot Ultrasound sensor with a selfwritten waveguide with all-optical ultrasound detection with high sensitivity. In previous work, we have shown an increase in resonator Q-factor from 1900 to 3200 for a simulated Fabry-Perot ultrasound detector of 45 μm thickness upon including a waveguide to limit lateral power losses. Subsequently, we demonstrated a prototype device with 30nm gold mirrors and a cavity composed of the photosensitive polymer Benzocyclobutene. This 80 µm thick device showed an improvement in its Q-factor from 2500 to 5200 after a selfaligned waveguide was written into the cavity using UV exposure. Current work uses a significantly faster fabrication technique using a combination of UV-cured epoxies for the cavity medium, and the waveguide within it. This reduces the fabrication time from several hours to a few minutes, and significantly lowers the cost of fabrication. We use a dip-coating technique to deposit the polymer layer. Future work will include the use of Dielectric Bragg mirrors in place of gold to achieve better reflectivity, thereby further improving the Q-factor of the device. The complete transducer presents an ideal solution for intravascular imaging in cases where tissue differentiation is desirable, an important feature in interventional procedures where arterial perforation is a risk. The final design proposed comprises the transducer within a guidewire to guide interventions for Chronic Total Occlusions, a disease state for which there are currently no invasive imaging options.

  7. Resolution, Scales and Predictability: Is High Resolution Detrimental To Predictability At Extended Forecast Times?

    Science.gov (United States)

    Mesinger, F.

    The traditional views hold that high-resolution limited area models (LAMs) down- scale large-scale lateral boundary information, and that predictability of small scales is short. Inspection of various rms fits/errors has contributed to these views. It would follow that the skill of LAMs should visibly deteriorate compared to that of their driver models at more extended forecast times. The limited area Eta Model at NCEP has an additional handicap of being driven by LBCs of the previous Avn global model run, at 0000 and 1200 UTC estimated to amount to about an 8 h loss in accuracy. This should make its relative skill compared to that of the Avn deteriorate even faster. These views are challenged by various Eta results including rms fits to raobs out to 84 h. It is argued that it is the largest scales that contribute the most to the skill of the Eta relative to that of the Avn.

  8. The prevalence of previous self-harm amongst self-poisoning patients in Sri Lanka

    DEFF Research Database (Denmark)

    Mohamed, Fahim; Perera, Aravinda; Wijayaweera, Kusal

    2011-01-01

    BACKGROUND: One of the most important components of suicide prevention strategies is to target people who repeat self-harm as they are a high risk group. However, there is some evidence that the incidence of repeat self-harm is lower in Asia than in the West. The objective of this study...... was to investigate the prevalence of previous self-harm among a consecutive series of self-harm patients presenting to hospitals in rural Sri Lanka. METHOD: Six hundred and ninety-eight self-poisoning patients presenting to medical wards at two hospitals in Sri Lanka were interviewed about their previous episodes...... of self-harm. RESULTS: Sixty-one (8.7%, 95% CI 6.7-11%) patients reported at least one previous episode of self-harm [37 (10.7%) male, 24 (6.8%) female]; only 19 (2.7%, 95% CI 1.6-4.2%) patients had made more than one previous attempt. CONCLUSION: The low prevalence of previous self-harm is consistent...

  9. High prevalence of genetic variants previously associated with LQT syndrome in new exome data

    DEFF Research Database (Denmark)

    Refsgaard, Lena; Holst, Anders G; Sadjadieh, Golnaz

    2012-01-01

    To date, hundreds of variants in 13 genes have been associated with long QT syndrome (LQTS). The prevalence of LQTS is estimated to be between 1:2000 and 1:5000. The knowledge of genetic variation in the general population has until recently been limited, but newly published data from NHLBI GO...... variants KCNH2 P347S; SCN5A: S216L, V1951L; and CAV3 T78M in the control population (n=704) revealed prevalences comparable to those of ESP. Thus, we identified a much higher prevalence of previously LQTS-associated variants than expected in exome data from population studies. Great caution regarding...

  10. About the coordinate time for photons in Lifshitz space-times

    International Nuclear Information System (INIS)

    Villanueva, J.R.; Vasquez, Yerko

    2013-01-01

    In this paper we studied the behavior of radial photons from the point of view of the coordinate time in (asymptotically) Lifshitz space-times, and we found a generalization to the result reported in previous works by Cruz et al. (Eur. Phys. J. C 73:7, 2013), Olivares et al. (Astrophys. Space Sci. 347:83-89, 2013), and Olivares et al. arXiv:1306.5285. We demonstrate that all asymptotically Lifshitz space-times characterized by a lapse function f(r) which tends to one when r→∞, present the same behavior, in the sense that an external observer will see that photons arrive at spatial infinity in a finite coordinate time. Also, we show that radial photons in the proper system cannot determine the presence of the black hole in the region r + < r<∞, because the proper time as a result is independent of the lapse function f(r). (orig.)

  11. Multiple-relaxation-time lattice Boltzmann model for incompressible miscible flow with large viscosity ratio and high Péclet number

    Science.gov (United States)

    Meng, Xuhui; Guo, Zhaoli

    2015-10-01

    A lattice Boltzmann model with a multiple-relaxation-time (MRT) collision operator is proposed for incompressible miscible flow with a large viscosity ratio as well as a high Péclet number in this paper. The equilibria in the present model are motivated by the lattice kinetic scheme previously developed by Inamuro et al. [Philos. Trans. R. Soc. London, Ser. A 360, 477 (2002), 10.1098/rsta.2001.0942]. The fluid viscosity and diffusion coefficient depend on both the corresponding relaxation times and additional adjustable parameters in this model. As a result, the corresponding relaxation times can be adjusted in proper ranges to enhance the performance of the model. Numerical validations of the Poiseuille flow and a diffusion-reaction problem demonstrate that the proposed model has second-order accuracy in space. Thereafter, the model is used to simulate flow through a porous medium, and the results show that the proposed model has the advantage to obtain a viscosity-independent permeability, which makes it a robust method for simulating flow in porous media. Finally, a set of simulations are conducted on the viscous miscible displacement between two parallel plates. The results reveal that the present model can be used to simulate, to a high level of accuracy, flows with large viscosity ratios and/or high Péclet numbers. Moreover, the present model is shown to provide superior stability in the limit of high kinematic viscosity. In summary, the numerical results indicate that the present lattice Boltzmann model is an ideal numerical tool for simulating flow with a large viscosity ratio and/or a high Péclet number.

  12. High Sr/Y rocks are not all adakites!

    Science.gov (United States)

    Moyen, Jean-François

    2010-05-01

    The name of "adakite" is used to describe a far too large group of rocks, whose sole common feature is high Sr/Y and La/Yb ratios. Defining adakites only by this criterion is misleading, as the definition of this group of rocks does include many other criteria, including major elements. In itself, high (or commonly moderate!) Sr/Y ratios can be achieved via different processes: melting of a high Sr/Y (and La/Yb) source; deep melting, with abundant residual garnet; fractional crystallization or AFC; or interactions of felsic melts with the mantle, causing selective enrichment in LREE and Sr over HREE. A database of the compositions of "adakitic" rocks - including "high silica" and "low silica" adakites, "continental" adakites and Archaean adakites—was assembled. Geochemical modeling of the potential processes is used to interpret it, and reveals that (1) the genesis of high-silica adakites requires high pressure evolution (be it by melting or fractionation), in equilibrium with large amounts of garnet; (2) low-silica adakites are explained by garnet-present melting of an adakite-metasomatized mantle, i.e at depths greater than 2.5 GPa; (3) "Continental" adakites is a term encompassing a huge range of rocks, with a corresponding diversity of petrogenetic processes, and most of them are different from both low- and high- silica adakites; in fact in many cases it is a complete misnomer and the rocks studied are high-K calc-alkaline granitoids or even S-type granites; (4) Archaean adakites show a bimodal composition range, with some very high Sr/Y examples (similar to part of the TTG suite) reflecting deep melting (> 2.0 GPa) of a basaltic source with a relatively high Sr/Y, while lower Sr/Y rocks formed by shallower (1.0 GPa) melting of similar sources. Comparison with the Archaean TTG suite highlights the heterogeneity of the TTGs, whose composition spreads the whole combined range of HSA and Archaean adakites, pointing to a diversity of sources and processes

  13. Memory and food intake in sheep: Effects of previous exposure to ...

    African Journals Online (AJOL)

    Animal behaviour pattern was monitored once every 5 min, over an 8-h period, immediately after first confinement. Frequency of eating, idling, ruminating, or drinking were all found to be significantly greater (P<0.001) for previously exposed lambs. Intakes of OM, N, DOM, and leaf fraction in straw were also significantly ...

  14. A comparison of morbidity associated with placenta previa with and without previous caesarean sections

    International Nuclear Information System (INIS)

    Baqai, S.; Siraj, A.; Noor, N.

    2018-01-01

    To compare the morbidity associated with placenta previa with and without previous caesarean sections. Study Design: Retrospective comparative study. Place and Duration of Study: From March 2014 till March 2016 in the department of Obstetrics and Gynaecology at PNS Shifa hospital Karachi. Material and Methods: After the approval from hospital ethical committee, antenatal patients with singleton pregnancy of gestational age >32 weeks, in the age group of 20-40 years diagnosed to have placenta previa included in the study. All patients with twin pregnancy less than 20 years and more than 40 years of age were excluded. The records of all patients fulfilling the inclusion criteria were reviewed. Data had been collected for demographic and maternal variables, placenta previa, history of previous lower segment caesarean section (LSCS), complications associated with placenta previa and techniques used to control blood loss were recorded. Results: During the study period, 6879 patients were delivered in PNS Shifa, out of these, 2060 (29.9%) had caesarean section out of these, 47.3% patients had previous history of LSCS. Thirty three (1.6%) patients were diagnosed to have placenta previa and frequency of placenta previa was significantly higher in patients with previous history of LSCS than previous normal delivery of LSCS i.e. 22 vs. 11 (p=0.023). It was observed that the frequency of morbidly adherent placenta (MAP) and Intensive care unit (ICU) stay were significantly higher in patients with previous history of LSCS than previous history of normal delivery. Conclusion: Frequency of placenta previa was significantly higher in patients with history of LSCS. Also placenta previa remains a major risk factor for various maternal complications. (author)

  15. Highly comparative time-series analysis: the empirical structure of time series and their methods.

    Science.gov (United States)

    Fulcher, Ben D; Little, Max A; Jones, Nick S

    2013-06-06

    The process of collecting and organizing sets of observations represents a common theme throughout the history of science. However, despite the ubiquity of scientists measuring, recording and analysing the dynamics of different processes, an extensive organization of scientific time-series data and analysis methods has never been performed. Addressing this, annotated collections of over 35 000 real-world and model-generated time series, and over 9000 time-series analysis algorithms are analysed in this work. We introduce reduced representations of both time series, in terms of their properties measured by diverse scientific methods, and of time-series analysis methods, in terms of their behaviour on empirical time series, and use them to organize these interdisciplinary resources. This new approach to comparing across diverse scientific data and methods allows us to organize time-series datasets automatically according to their properties, retrieve alternatives to particular analysis methods developed in other scientific disciplines and automate the selection of useful methods for time-series classification and regression tasks. The broad scientific utility of these tools is demonstrated on datasets of electroencephalograms, self-affine time series, heartbeat intervals, speech signals and others, in each case contributing novel analysis techniques to the existing literature. Highly comparative techniques that compare across an interdisciplinary literature can thus be used to guide more focused research in time-series analysis for applications across the scientific disciplines.

  16. Keeping the security and the relief in the environment where radioactive materials exist all the times

    International Nuclear Information System (INIS)

    Murata, Takashi

    2014-01-01

    Three-Eleven was a turning point after which we have recognized that are surrounded by the radioactive materials all the times. On the other hand, “getting a claim to edit by any individual” became possible owing to the spread of advanced ICT equipment, and now he can get necessary information for him to decide and act as he want. It is important for keeping security and rejecting anxiety against radiation to record and evaluate personal irradiation information utilizing the results of ICT. The results should be timely returned to the concerned person. At the same time, it necessary to establish the system by which the data are compiled as a big data and are opened for public use. For establishing such system, the promotion of interdisciplinary collaboration is expected. (J.P.N.)

  17. Adolescents' sleep in low-stress and high-stress (exam) times: a prospective quasi-experiment.

    Science.gov (United States)

    Dewald, Julia F; Meijer, Anne Marie; Oort, Frans J; Kerkhof, Gerard A; Bögels, Susan M

    2014-01-01

    This prospective quasi-experiment (N = 175; mean age = 15.14 years) investigates changes in adolescents' sleep from low-stress (regular school week) to high-stress times (exam week), and examines the (moderating) role of chronic sleep reduction, baseline stress, and gender. Sleep was monitored over three consecutive weeks using actigraphy. Adolescents' sleep was more fragmented during the high-stress time than during the low-stress time, meaning that individuals slept more restless during stressful times. However, sleep efficiency, total sleep time, and sleep onset latency remained stable throughout the three consecutive weeks. High chronic sleep reduction was related to later bedtimes, later sleep start times, later sleep end times, later getting up times, and more time spent in bed. Furthermore, low chronic sleep reduction and high baseline stress levels were related to more fragmented sleep during stressful times. This study shows that stressful times can have negative effects on adolescents' sleep fragmentation, especially for adolescents with low chronic sleep reduction or high baseline stress levels.

  18. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  19. A Shell Multi-dimensional Hierarchical Cubing Approach for High-Dimensional Cube

    Science.gov (United States)

    Zou, Shuzhi; Zhao, Li; Hu, Kongfa

    The pre-computation of data cubes is critical for improving the response time of OLAP systems and accelerating data mining tasks in large data warehouses. However, as the sizes of data warehouses grow, the time it takes to perform this pre-computation becomes a significant performance bottleneck. In a high dimensional data warehouse, it might not be practical to build all these cuboids and their indices. In this paper, we propose a shell multi-dimensional hierarchical cubing algorithm, based on an extension of the previous minimal cubing approach. This method partitions the high dimensional data cube into low multi-dimensional hierarchical cube. Experimental results show that the proposed method is significantly more efficient than other existing cubing methods.

  20. Dissociation in decision bias mechanism between probabilistic information and previous decision

    Directory of Open Access Journals (Sweden)

    Yoshiyuki eKaneko

    2015-05-01

    Full Text Available Target detection performance is known to be influenced by events in the previous trials. It has not been clear, however, whether this bias effect is due to the previous sensory stimulus, motor response, or decision. Also it remains open whether or not the previous trial effect emerges via the same mechanism as the effect of knowledge about the target probability. In the present study, we asked normal human subjects to make a decision about the presence or absence of a visual target. We presented a pre-cue indicating the target probability before the stimulus, and also a decision-response mapping cue after the stimulus so as to tease apart the effect of decision from that of motor response. We found that the target detection performance was significantly affected by the probability cue in the current trial and also by the decision in the previous trial. While the information about the target probability modulated the decision criteria, the previous decision modulated the sensitivity to target-relevant sensory signals (d-prime. Using functional magnetic resonance imaging, we also found that activation in the left intraparietal sulcus was decreased when the probability cue indicated a high probability of the target. By contrast, activation in the right inferior frontal gyrus was increased when the subjects made a target-present decision in the previous trial, but this change was observed specifically when the target was present in the current trial. Activation in these regions was associated with individual-difference in the decision computation parameters. We argue that the previous decision biases the target detection performance by modulating the processing of target-selective information, and this mechanism is distinct from modulation of decision criteria due to expectation of a target.

  1. Dissociation in decision bias mechanism between probabilistic information and previous decision

    Science.gov (United States)

    Kaneko, Yoshiyuki; Sakai, Katsuyuki

    2015-01-01

    Target detection performance is known to be influenced by events in the previous trials. It has not been clear, however, whether this bias effect is due to the previous sensory stimulus, motor response, or decision. Also it remains open whether or not the previous trial effect emerges via the same mechanism as the effect of knowledge about the target probability. In the present study, we asked normal human subjects to make a decision about the presence or absence of a visual target. We presented a pre-cue indicating the target probability before the stimulus, and also a decision-response mapping cue after the stimulus so as to tease apart the effect of decision from that of motor response. We found that the target detection performance was significantly affected by the probability cue in the current trial and also by the decision in the previous trial. While the information about the target probability modulated the decision criteria, the previous decision modulated the sensitivity to target-relevant sensory signals (d-prime). Using functional magnetic resonance imaging (fMRI), we also found that activation in the left intraparietal sulcus (IPS) was decreased when the probability cue indicated a high probability of the target. By contrast, activation in the right inferior frontal gyrus (IFG) was increased when the subjects made a target-present decision in the previous trial, but this change was observed specifically when the target was present in the current trial. Activation in these regions was associated with individual-difference in the decision computation parameters. We argue that the previous decision biases the target detection performance by modulating the processing of target-selective information, and this mechanism is distinct from modulation of decision criteria due to expectation of a target. PMID:25999844

  2. Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions.

    Science.gov (United States)

    Lu, W; Li, J Y; Kang, L; Liu, H P; Li, H; Li, J D; Sun, L T; Ma, X W

    2014-02-01

    The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36,000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H(+), (40)Ar(8+), (129)Xe(30+), (209)Bi(33+), etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform.

  3. Physics For All -- yes, it's real physics

    Science.gov (United States)

    Eisenkraft, Arthur

    2012-02-01

    Can ``all'' students learn ``real'' physics? We want to provide instruction to a wider segment of the population including those students who will not go into STEM (Science, Technology, Engineering, Math) careers. We also want to maintain the integrity of physics, challenge all students, and not compromise the rigor of our courses. Accomplishing this requires a research guided approach to instruction, curriculum and assessment. Physics First and Physics for All have become a success story for thousands of students in urban, suburban, and rural districts. At the same time, the International Physics Olympiad and other competitions have raised the expectation of what the most motivated students can achieve. Many physics educators are exploring ways to set higher goals for our most gifted students while also providing physics instruction to students previously excluded from our physics classes. Many of the same issues that K-12 educators are struggling with are equally important to the college community as colleges try to educate both future physicists and an educated citizenry. Great novels and symphonies are accessible to people of different backgrounds and levels of expertise. We should develop strategies that enable us to share an understanding of physics with all students because everyone deserves an opportunity to reflect on the wondrous workings of our universe.

  4. IoT for Real-Time Measurement of High-Throughput Liquid Dispensing in Laboratory Environments.

    Science.gov (United States)

    Shumate, Justin; Baillargeon, Pierre; Spicer, Timothy P; Scampavia, Louis

    2018-04-01

    Critical to maintaining quality control in high-throughput screening is the need for constant monitoring of liquid-dispensing fidelity. Traditional methods involve operator intervention with gravimetric analysis to monitor the gross accuracy of full plate dispenses, visual verification of contents, or dedicated weigh stations on screening platforms that introduce potential bottlenecks and increase the plate-processing cycle time. We present a unique solution using open-source hardware, software, and 3D printing to automate dispenser accuracy determination by providing real-time dispense weight measurements via a network-connected precision balance. This system uses an Arduino microcontroller to connect a precision balance to a local network. By integrating the precision balance as an Internet of Things (IoT) device, it gains the ability to provide real-time gravimetric summaries of dispensing, generate timely alerts when problems are detected, and capture historical dispensing data for future analysis. All collected data can then be accessed via a web interface for reviewing alerts and dispensing information in real time or remotely for timely intervention of dispense errors. The development of this system also leveraged 3D printing to rapidly prototype sensor brackets, mounting solutions, and component enclosures.

  5. A Low-Cost Time-Hopping Impulse Radio System for High Data Rate Transmission

    Directory of Open Access Journals (Sweden)

    Jinyun Zhang

    2005-03-01

    Full Text Available We present an efficient, low-cost implementation of time-hopping impulse radio that fulfills the spectral mask mandated by the FCC and is suitable for high-data-rate, short-range communications. Key features are (i all-baseband implementation that obviates the need for passband components, (ii symbol-rate (not chip rate sampling, A/D conversion, and digital signal processing, (iii fast acquisition due to novel search algorithms, and (iv spectral shaping that can be adapted to accommodate different spectrum regulations and interference environments. Computer simulations show that this system can provide 110 Mbps at 7–10 m distance, as well as higher data rates at shorter distances under FCC emissions limits. Due to the spreading concept of time-hopping impulse radio, the system can sustain multiple simultaneous users, and can suppress narrowband interference effectively.

  6. A nanosecond high voltage pulse device for accelerator time analytical system

    International Nuclear Information System (INIS)

    Lou Binqiao; Ding Furong; Xue Zhihua; Wang Xuemei; Shen Dingyu

    2002-01-01

    A nanosecond high voltage pulse device has been designed. The pulse rise time is 10 ns. The pulse voltage reached 16000 V. This device has been used to accelerator time analytical system, its resolution time is less than 0.8%

  7. Ultra-high-performance liquid chromatography-Time-of-flight high resolution mass spectrometry to quantify acidic drugs in wastewater.

    Science.gov (United States)

    Becerra-Herrera, Mercedes; Honda, Luis; Richter, Pablo

    2015-12-04

    A novel analytical approach involving an improved rotating-disk sorptive extraction (RDSE) procedure and ultra-high-performance liquid chromatography (UHPLC) coupled to an ultraspray electrospray ionization source (UESI) and time-of-flight mass spectrometry (TOF/MS), in trap mode, was developed to identify and quantify four non-steroidal anti-inflammatory drugs (NSAIDs) (naproxen, ibuprofen, ketoprofen and diclofenac) and two anti-cholesterol drugs (ACDs) (clofibric acid and gemfibrozil) that are widely used and typically found in water samples. The method reduced the amount of both sample and reagents used and also the time required for the whole analysis, resulting in a reliable and green analytical strategy. The analytical eco-scale was calculated, showing that this methodology is an excellent green analysis, increasing its ecological worth. The detection limits (LOD) and precision (%RSD) were lower than 90ng/L and 10%, respectively. Matrix effects and recoveries were studied using samples from the influent of a wastewater treatment plant (WWTP). All the compounds exhibited suppression of their signals due to matrix effects, and the recoveries were approximately 100%. The applicability and reliability of this methodology were confirmed through the analysis of influent and effluent samples from a WWTP in Santiago, Chile, obtaining concentrations ranging from 1.1 to 20.5μg/L and from 0.5 to 8.6μg/L, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. STUDY OF EFFECTIVE TIME OF UNDILUTED FIXINGSOLUTIONS INLIGHTENING OF THE HIGH DENSITY PERIAPICAL RADIOGRAPHS

    Directory of Open Access Journals (Sweden)

    A ZAMANI NASER

    2003-12-01

    Full Text Available Introduction: Dental radiographs are occationally too dark because of different reasons such as over exposure, high concen-tration of developing solution and over development. Different chemicals are used to lighten these radiographs. In this research the undiluted fixed solution for the first time are tested and efficiency time of this solution in reducing the density of dark radiographs were evaluated. Method: Use of a dry mandible containing some teeth and 98 E speed periapical radiographs were prepared as foolow: A film wasexposed with 0.4 S... as positive control (ideal. 97 films were exposed with 1.8 S (dark and unreadable. Out of 97, one radiograph kept as positive control and remaining films prepared for study. All of radiographs developed and fixed with automatic processor in the same conditio. Out of 96 dark radiograph, 3 was used for pilot study and inserted in the undiluted fixing solution in different time. (2.5, 3 and 3.5 hrs. The result of pilot study showed that aii3 radiographs showed reductionin density and radiographs with her reduction time was closest to positive control for density and diognostic quality and radiograph with 2.5 hrs reduction time and 3.5 hre became darker and lighter as compared to positive control. The remaining 93 high density radiographs were divided into 3 groups, 31 in each group (group 1,2 and 3 first group 2.5 hrs, second 3 hrs and the third group 3.5 hrs were kept in undiluted fixed solution. for this, disposable glasses were used and in each glass a radiograph were inserted. The research time was spring and the temperature was about 2609 (without coolant. Evaluation of radiographs: For evaluation of radiographs 2 methods were used: First method used was: Densitometry: By this method the density of total lightened radiographs, positive control and negative control were determined. Another method was determined diagnostic quality of radiographs visually by radiologists, throng this way: Special

  9. Rossi X-Ray Timing Explorer All-Sky Monitor Localization of SGR 1627-41

    Science.gov (United States)

    Smith, Donald A.; Bradt, Hale V.; Levine, Alan M.

    1999-07-01

    The fourth unambiguously identified soft gamma repeater (SGR), SGR 1627-41, was discovered with the BATSE instrument on 1998 June 15. Interplanetary Network (IPN) measurements and BATSE data constrained the location of this new SGR to a 6° segment of a narrow (19") annulus. We present two bursts from this source observed by the All-Sky Monitor (ASM) on the Rossi X-Ray Timing Explorer. We use the ASM data to further constrain the source location to a 5' long segment of the BATSE/IPN error box. The ASM/IPN error box lies within 0.3 arcmin of the supernova remnant G337.0-0.1. The probability that a supernova remnant would fall so close to the error box purely by chance is ~5%.

  10. Comparison of the clinical performances of the AdvanSure HPV Screening Real-Time PCR, the Abbott Real-Time High-Risk HPV Test, and the Hybrid Capture High-Risk HPV DNA Test for Cervical Cancer Screening.

    Science.gov (United States)

    Chung, Hae-Sun; Hahm, Chorong; Lee, Miae

    2014-09-01

    The clinical performance of three human papillomavirus (HPV) DNA commercial assays for cervical cancer screening was evaluated; the AdvanSure HPV Screening Real-Time PCR (AdvanSure PCR; LG Life Sciences) that was developed recently for the detection of both high-risk and low-risk genotypes, the Abbott RealTime High-Risk HPV Test (Abbott PCR; Abbott Molecular) and the Hybrid Capture High-Risk HPV DNA test (HC2; Qiagen). The three different HPV DNA tests were compared using cytology samples obtained from 619 women who underwent routine cervical cancer screening. The gold-standard assay was histopathological confirmation of cervical intraepithelial neoplasia of grade 2 or worse. The clinical sensitivities of the AdvanSure PCR, the Abbott PCR and the HC2 for the detection of cervical intraepithelial neoplasia of grade 2 or worse were 95.5%, 95.5% and 100%, respectively, while the clinical specificities were 61.6%, 86.4% and 83.3%, respectively. There were no significant differences in the clinical sensitivities of the Abbott PCR and the AdvanSure PCR compared to the HC2. The clinical specificities of the Abbott PCR and the AdvanSure PCR for the detection of HPV types 16/18 were 97.8% and 98.5%, respectively. For cervical cancer screening, all three tests showed relatively good clinical sensitivities, but the AdvanSure PCR had lower clinical specificity than the Abbott PCR and the HC2. The AdvanSure PCR and the Abbott PCR assays have the advantage of being automated and the ability to distinguish between HPV types 16/18 and other HPV types. The two real-time PCR assays could be useful tools in HPV testing for cervical cancer screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. A PRACTICAL MODEL OF LOW-VOLUME HIGH-INTENSITY INTERVAL TRAINING INDUCES PERFORMANCE AND METABOLIC ADAPTATIONS THAT RESEMBLE 'ALL-OUT' SPRINT INTERVAL TRAINING

    Directory of Open Access Journals (Sweden)

    Mahdi Bayati

    2011-09-01

    Full Text Available Recently, a novel type of high-intensity interval training known as sprint interval training has demonstrated increases in aerobic and anaerobic performance with very low time commitment. However, this type of training program is unpractical for general populations. The present study compared the impact of a low-volume high-intensity interval training to a "all-out" sprint interval training. Twenty-four active young males were recruited and randomized into three groups: (G1: 3-5 cycling bouts × 30-s all-out with 4 min recovery; G2: 6- 10 cycling bouts × 125% Pmax with 2 min recovery and a non-trained control group. They all performed a VO2max test, a time to exhaustion at Pmax (Tmax and a Wingate test before and after the intervention. Capillary blood lactate was taken at rest, 3, and 20 min after the Wingate trial. Training was performed 3 sessions per week for 4 weeks. In G1, significant improvements (p < 0.05 following training were found in VO2max (9.6%, power at VO2max (12.8%, Tmax (48.4%, peak power output (10.3% and mean power output (17.1%. In G2, significant improvements following training were found in VO2max (9.7%, power at VO2max (16.1%, Tmax (54.2%, peak power output (7.4%; p < 0.05, but mean power output did not change significantly. Blood lactate recovery (20th min significantly decreased in G1 and G2 when compared with pre-testing and the CON group (p < 0.05. In conclusion, the results of the current study agree with earlier work demonstrating the effectiveness of 30-s all-out training program to aerobic and anaerobic adaptations. Of substantial interest is that the low volume high intensity training provides similar results but involves only half the intensity with double the repetitions

  12. High resolution fast neutron spectrometry without time-of-flight

    International Nuclear Information System (INIS)

    Evans, A.E.; Brandenberger, J.D.

    1978-01-01

    Performance tests of a spectrometer tube of the type developed by Cuttler and Shalev show that the measurement of fast neutron spectra with this device can be made with an energy resolution previously obtainable only in large time-of-flight facilities. In preliminary tests, resolutions of 16.4 keV for thermal neutrons and 30.9 keV for 1-MeV neutrons were obtained. A broad-window pulse-shape discrimination (PSD) system is used to remove from pulse-height distributions most of the continua due to 3 He-recoil events, noise, and wall effect. Use of PSD improved the energy resolution to 12.9 keV for thermal neutrons and 29.2 keV for 1-MeV neutrons. The detector is a viable tool for neutron research at nominally equipped accelerator laboratories

  13. Testing and Validation of Timing Properties for High Speed Digital Cameras - A Best Practices Guide

    Science.gov (United States)

    2016-07-27

    range, and frame rate get all the press when it comes to high-speed video viewed in Range Control; however, most optical data is practically...introduction of hydraulic and electrically-driven mount servo systems  The replacement of fixed optics sites with remotely-controlled mobile systems  The...support (e.g., VendorX Timing Tests with staggered 10-μs pulse sequence). (5) Select Press to Locate Board ID. The Define Board ID file should

  14. High-Order Calderón Preconditioned Time Domain Integral Equation Solvers

    KAUST Repository

    Valdes, Felipe; Ghaffari-Miab, Mohsen; Andriulli, Francesco P.; Cools, Kristof; Michielssen,

    2013-01-01

    Two high-order accurate Calderón preconditioned time domain electric field integral equation (TDEFIE) solvers are presented. In contrast to existing Calderón preconditioned time domain solvers, the proposed preconditioner allows for high-order surface representations and current expansions by using a novel set of fully-localized high-order div-and quasi curl-conforming (DQCC) basis functions. Numerical results demonstrate that the linear systems of equations obtained using the proposed basis functions converge rapidly, regardless of the mesh density and of the order of the current expansion. © 1963-2012 IEEE.

  15. High-Order Calderón Preconditioned Time Domain Integral Equation Solvers

    KAUST Repository

    Valdes, Felipe

    2013-05-01

    Two high-order accurate Calderón preconditioned time domain electric field integral equation (TDEFIE) solvers are presented. In contrast to existing Calderón preconditioned time domain solvers, the proposed preconditioner allows for high-order surface representations and current expansions by using a novel set of fully-localized high-order div-and quasi curl-conforming (DQCC) basis functions. Numerical results demonstrate that the linear systems of equations obtained using the proposed basis functions converge rapidly, regardless of the mesh density and of the order of the current expansion. © 1963-2012 IEEE.

  16. High resolution separations of charge variants and disulfide isomers of monoclonal antibodies and antibody drug conjugates using ultra-high voltage capillary electrophoresis with high electric field strength.

    Science.gov (United States)

    Henley, W Hampton; He, Yan; Mellors, J Scott; Batz, Nicholas G; Ramsey, J Michael; Jorgenson, James W

    2017-11-10

    Ultra-high voltage capillary electrophoresis with high electric field strength has been applied to the separation of the charge variants, drug conjugates, and disulfide isomers of monoclonal antibodies. Samples composed of many closely related species are difficult to resolve and quantify using traditional analytical instrumentation. High performance instrumentation can often save considerable time and effort otherwise spent on extensive method development. Ideally, the resolution obtained for a given CE buffer system scales with the square root of the applied voltage. Currently available commercial CE instrumentation is limited to an applied voltage of approximately 30kV and a maximum electric field strength of 1kV/cm due to design limitations. The instrumentation described here is capable of safely applying potentials of at least 120kV with electric field strengths over 2000V/cm, potentially doubling the resolution of the best conventional CE buffer/capillary systems while decreasing analysis time in some applications. Separations of these complex mixtures using this new instrumentation demonstrate the potential of ultra-high voltage CE to identify the presence of previously unresolved components and to reduce analysis time for complex mixtures of antibody variants and drug conjugates. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Is Uric Acid a Missing Link between Previous Gestational Diabetes Mellitus and the Development of Type 2 Diabetes at a Later Time of Life?

    Directory of Open Access Journals (Sweden)

    Piotr Molęda

    Full Text Available A high level of uric acid (UA is a strong, independent risk factor for type 2 diabetes mellitus. The relationship between UA levels and the development of type 2 diabetes in women with previous gestational diabetes mellitus (pGDM remains unclear. The aim of study was to evaluate the UA levels in pGDM women in relation to their current nutritional status and carbohydrate metabolism.199 women with pGDM diagnoses based on oral glucose tolerance tests (OGTTs 5-12 years previously and a control group of 50 women without pGDM. The assessment included anthropometric parameters, body composition (Tanita SC-330S, current OGTT, insulin resistance index (HOMA-IR, β-cell function (HOMA-%B, HbA1c, lipids, and uric acid.No differences between groups were found in terms of age, time from the index pregnancy, anthropometric parameters, lipids or creatinine levels. The incidences of overweight and obesity were similar. Carbohydrate abnormalities were more frequent in the pGDM group than the control group (43.2% vs 12.0% p<0.001. The women with pGDM had significantly higher fasting glucose, HbA1c, glucose and insulin levels in the OGTTs, but similar HOMA-IR values. Their UA levels were significantly higher (258±58 vs 230±50 μmol/L, p<0.005 and correlated with BMI and the severity of carbohydrate disorders. The normal weight and normoglycemic pGDM women also demonstrated higher UA levels than a similar control subgroup (232±48 vs 208±48 μmol/L, p<0.05. Multivariate analysis revealed significant correlations of UA level with BMI (β = 0.38, 95% CI 0.25-0.51, p<0.0001, creatinine level (β = 0.23, 95% CI 0.11-0.35, p<0.0005, triglycerides (β = 0.20, 95% CI 0.07-0.33, p<0.005 and family history of diabetes (β = 0.13, 95% CI 0.01-0.25, p<0.05. In logistic regression analysis, the association between higher UA level (defined as value ≥297 μmol/L and presence of any carbohydrate metabolism disorder (IFG, IGT or diabetes was statistically significant (odds

  18. Increased risk of default among previously treated tuberculosis cases in the Western Cape Province, South Africa.

    Science.gov (United States)

    Marx, F M; Dunbar, R; Hesseling, A C; Enarson, D A; Fielding, K; Beyers, N

    2012-08-01

    To investigate, in two urban communities with high tuberculosis (TB) incidence and high rates of TB recurrence, whether a history of previous TB treatment is associated with treatment default. Retrospective cohort study of TB cases with an episode of treatment recorded in the clinic-based treatment registers between 2002 and 2007. Probabilistic record linkage was used to ascertain treatment history of TB cases back to 1996. Based on the outcome of their most recent previous treatment episode, previously treated cases were compared to new cases regarding their risk of treatment default. Previous treatment success (adjusted odds ratio [aOR] 1.79; 95%CI 1.17-2.73), previous default (aOR 6.18, 95%CI 3.68-10.36) and previous failure (aOR 9.72, 95%CI 3.07-30.78) were each independently associated with treatment default (P default were male sex (P = 0.003) and age 19-39 years (P risk of treatment default, even after previous successful treatment. This finding is of particular importance in a setting where recurrent TB is very common. Adherence to treatment should be ensured in new and retreatment cases to increase cure rates and reduce transmission of TB in the community.

  19. Optoelectronic properties of XIn2S4 (X = Cd, Mg) thiospinels through highly accurate all-electron FP-LAPW method coupled with modified approximations

    International Nuclear Information System (INIS)

    Yousaf, Masood; Dalhatu, S.A.; Murtaza, G.; Khenata, R.; Sajjad, M.; Musa, A.; Rahnamaye Aliabad, H.A.; Saeed, M.A.

    2015-01-01

    Highlights: • Highly accurate all-electron FP-LAPW+lo method is used. • New physical parameters are reported, important for the fabrication of optoelectronic devices. • A comparative study that involves FP-LAPW+lo method and modified approximations. • Computed band gap values have good agreement with the experimental values. • Optoelectronic results of fundamental importance can be utilized for the fabrication of devices. - Abstract: We report the structural, electronic and optical properties of the thiospinels XIn 2 S 4 (X = Cd, Mg), using highly accurate all-electron full potential linearized augmented plane wave plus local orbital method. In order to calculate the exchange and correlation energies, the method is coupled with modified techniques such as GGA+U and mBJ-GGA, which yield improved results as compared to the previous studies. GGA+SOC approximation is also used for the first time on these compounds to examine the spin orbit coupling effect on the band structure. From the analysis of the structural parameters, robust character is predicted for both materials. Energy band structures profiles are fairly the same for GGA, GGA+SOC, GGA+U and mBJ-GGA, confirming the indirect and direct band gap nature of CdIn 2 S 4 and MgIn 2 S 4 materials, respectively. We report the trend of band gap results as: (mBJ-GGA) > (GGA+U) > (GGA) > (GGA+SOC). Localized regions appearing in the valence bands for CdIn 2 S 4 tend to split up nearly by ≈1 eV in the case of GGA+SOC. Many new physical parameters are reported that can be important for the fabrication of optoelectronic devices. Optical spectra namely, dielectric function (DF), refractive index n(ω), extinction coefficient k(ω), reflectivity R(ω), optical conductivity σ(ω), absorption coefficient α(ω) and electron loss function are discussed. Optical’s absorption edge is noted to be 1.401 and 1.782 for CdIn 2 S 4 and MgIn 2 S 4 , respectively. The prominent peaks in the electron energy spectrum

  20. Design of the all solid high-voltage power supply for a gyrotron body

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Yihua [School of Mathematics and Physics, University of South China, Hengyang, 421001 (China); Chen, Wenguang, E-mail: 430000485393@usc.edu.cn [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Hu, Bo [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Rao, Jun; Huang, Mei; Kang, Zihua; Feng, Kun [Southwestern Institute of Physics, Chengdu, 610041 (China); Huang, Jiaqi [School of Electrical Engineering, University of South China, Hengyang, 421001 (China)

    2017-04-15

    Highlights: • Completed design of all solid-state high-voltage power supply for gyrotron body on HL-2M ECRH. • Consist of 58 PSM modules and one BUCK module, controlled by DSP system. • Fabricated full voltage 35 kV, 200 mA BPS and tested in dummy load. • The BPS can operate in three modes: single pulse mode, multi-pulse modulation mode and the six-level preset mode. - Abstract: Gyrotron plays an important role in the research of electron cyclotron resonance heating (ECRH) on Tokomak. The high-frequency switched power supply technology and pulse step modulation (PSM) technology are used in the development of the all solid high-voltage body power supply (BPS) for 1 MW/105 GHz Gyrotron on ECRH system. Firstly, the basic structure of the BPS and its control system are introduced. Secondly, the software control algorithm of voltage stabilization and modulate method are developed. Finally, the design is verified by the experiments. The experimental results of the single pulse mode, the multi-pulse modulation mode and the six-level preset mode, are shown. The output voltage of the power supply can reach 35 kV and the current at about 200 mA, which are adjustable in the full range. The maximum modulation frequency can reach 1 kHz and the front edge of the pulse can be adjust from 0 to 3 ms and the accuracy of the output voltage is less than 100 V. The results show that the control method is feasible and can be applied to other high power microwave sources.

  1. Printed all-solid flexible microsupercapacitors: towards the general route for high energy storage devices

    International Nuclear Information System (INIS)

    Wang, Ye; Shi, Yumeng; Zhao, Cheng Xi; Wong, Jen It; Yang, Hui Ying; Sun, Xiao Wei

    2014-01-01

    A novel method for fabricating all-solid flexible microsupercapacitors (MSCs) was proposed and developed by utilizing screen printing technology. A typical printed MSC is composed of a printed Ag electrode, MnO 2 /onion-like carbon (MnO 2 /OLC) as active material and a polyvinyl alcohol:H 3 PO 4 (PVA:H 3 PO 4 ) as solid electrolyte. A capacity of 7.04 mF cm −2 was achieved for the screen printed MnO 2 /OLC MSCs at a current density of 20 μA cm −2 . It also showed an excellent cycling stability, with 80% retention of the specific capacity after 1000 cycles. The printed all-solid flexible MSCs exhibited remarkably high mechanical flexibility when the devices were bent to a radius of 3.5 mm. In addition, all-solid MSCs were successfully demonstrated by screen printing technique on various substrates, such as silicon, glass and conventional printing paper. Moreover, the screen printing technique can be extended to other active materials, such as OLC and carbon nanotubes. This method provides a general route for printable all-solid flexible MSCs, which is compatible with the roll-to-roll process for various high performance active materials. (paper)

  2. Low-Power Amplifier-Discriminators for High Time Resolution Detection

    CERN Document Server

    Despeisse, M; Anghinolfi, F; Tiuraniemi, S; Osmic, F; Riedler, P; Kluge, A; Ceccucci, A

    2009-01-01

    Low-power amplifier-discriminators based on a so-called NINO architecture have been developed with high time resolution for the readout of radiation detectors. Two different circuits were integrated in the NINO13 chip, processed in IBM 130 nm CMOS technology. The LCO version (Low Capacitance and consumption Optimization) was designed for potential use as front-end electronics in the Gigatracker of the NA62 experiment at CERN. It was developed as pixel readout for solid-state pixel detectors to permit minimum ionizing particle detection with less than 180 ps rms resolution per pixel on the output pulse, for power consumption below 300 mu W per pixel. The HCO version (High Capacitance Optimization) was designed with 4 mW power consumption per channel to provide timing resolution below 20 ps rms on the output pulse, for charges above 10 fC. Results presented show the potential of the LCO and HCO circuits for the precise timing readout of solid-state detectors, vacuum tubes or gas detectors, for applications in h...

  3. High sensitivity and high Q-factor nanoslotted parallel quadrabeam photonic crystal cavity for real-time and label-free sensing

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Daquan [Rowland Institute at Harvard University, Cambridge, Massachusetts 02142 (United States); State Key Laboratory of Information Photonics and Optical Communications, School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876 (China); School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138 (United States); Kita, Shota; Wang, Cheng; Lončar, Marko [School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138 (United States); Liang, Feng; Quan, Qimin [Rowland Institute at Harvard University, Cambridge, Massachusetts 02142 (United States); Tian, Huiping; Ji, Yuefeng [State Key Laboratory of Information Photonics and Optical Communications, School of Information and Communication Engineering, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2014-08-11

    We experimentally demonstrate a label-free sensor based on nanoslotted parallel quadrabeam photonic crystal cavity (NPQC). The NPQC possesses both high sensitivity and high Q-factor. We achieved sensitivity (S) of 451 nm/refractive index unit and Q-factor >7000 in water at telecom wavelength range, featuring a sensor figure of merit >2000, an order of magnitude improvement over the previous photonic crystal sensors. In addition, we measured the streptavidin-biotin binding affinity and detected 10 ag/mL concentrated streptavidin in the phosphate buffered saline solution.

  4. Intake of wine, beer and spirits and waiting time to pregnancy

    DEFF Research Database (Denmark)

    Juhl, Mette; Olsen, Jørn; Andersen, Anne-Marie Nybo

    2003-01-01

    BACKGROUND: A high intake of alcohol may prolong waiting time to pregnancy, whereas a moderate intake may have no or perhaps even a positive effect on fecundity. In previous studies on fecundity, different types of beverages have not been taken into consideration, although moderate wine drinkers...... appear to have fewer strokes, lung and digestive tract cancers, and overall mortality than both abstainers and moderate drinkers of beer or spirits. We examined the association between different types of alcoholic beverages and waiting time to pregnancy. METHODS: Self-reported data were used for 29......,844 pregnant women, recruited to the Danish National Birth Cohort in 1997-2000. Main outcome measures were odds ratios for a prolonged waiting time to pregnancy according to consumption of wine, beer and spirits. RESULTS: All levels of wine intake compared with non-wine drinking or with consumption of beer...

  5. In vitro effect of hemodilution on activated clotting time and high-dose thrombin time during cardiopulmonary bypass

    NARCIS (Netherlands)

    Huyzen, RJ; vanOeveren, W; Wei, FY; Stellingwerf, P; Boonstra, PW; Gu, YJ

    Background. Extreme dilution of clotting factors, as may occur during pediatric or neonatal cardiopulmonary bypass, often leads to inadequate monitoring of anticoagulation with activated dotting time (ACT). In this study we postulate that the high-dose thrombin time (HiTT) is less influenced by

  6. Complete all-atom hydrodynamics of protein unfolding in uniform flow

    International Nuclear Information System (INIS)

    Wang, Guan M; Sandberg, William C

    2010-01-01

    The unfolding dynamics of a protein, ubiquitin, pinned in several uniform flows, was studied at low and high flow rates in an all-atom style through a non-equilibrium molecular dynamics approach with explicit water molecules included. Atomic hydrodynamic force components on individual amino acids, as a function of time, due to the collisional interactions with the flowing water molecules were calculated explicitly. The protein conformational change in response to those time-varying forces was computed completely at the high flow rate up to nanosecond until the fully stretched state was reached. The end-to-end length of the single ubiquitin protein molecule at high flow rate is smoothly increasing. The step-like jumps between metastable states that describe the μm ms -1 scale force pulling experiments conducted on polyubiquitins at low flow rates, are not seen at the high flow speeds necessary to computationally probe the ns nm -1 scale regime. No unfolding was observed in the low flow rate atomic computations at nanosecond scale while partial and complete unfolding was observed in the coarse-grained low flow rate computations at microsecond scale. Examination of the all-atom computation of the time variation of the hydrodynamic forces on, and the velocity components of, the protein molecule unveiled to some extent the details of the complexity of the hydrodynamic friction variation in the nm ns -1 regime of high rate flow-driven protein unfolding. This demonstrates quantitatively that all-atom computations are more suitable than the Langevin equation or Brownian dynamics methods for probing the interaction dynamics and resulting conformational dynamics of protein unfolding in strong flows on nm ns -1 time/length scales while the reverse is true for investigation of slow, diffusively driven systems.

  7. About the coordinate time for photons in Lifshitz space-times

    Energy Technology Data Exchange (ETDEWEB)

    Villanueva, J.R. [Universidad de Valparaiso, Departamento de Fisica y Astronomia, Facultad de Ciencias, Valparaiso (Chile); Centro de Astrofisica de Valparaiso, Valparaiso (Chile); Vasquez, Yerko [Universidad de La Frontera, Departamento de Ciencias Fisicas, Facultad de Ingenieria, Ciencias y Administracion, Temuco (Chile); Universidad de La Serena, Departamento de Fisicas, Facultad de Ciencias, La Serena (Chile)

    2013-10-15

    In this paper we studied the behavior of radial photons from the point of view of the coordinate time in (asymptotically) Lifshitz space-times, and we found a generalization to the result reported in previous works by Cruz et al. (Eur. Phys. J. C 73:7, 2013), Olivares et al. (Astrophys. Space Sci. 347:83-89, 2013), and Olivares et al. arXiv:1306.5285. We demonstrate that all asymptotically Lifshitz space-times characterized by a lapse function f(r) which tends to one when r{yields}{infinity}, present the same behavior, in the sense that an external observer will see that photons arrive at spatial infinity in a finite coordinate time. Also, we show that radial photons in the proper system cannot determine the presence of the black hole in the region r{sub +}time as a result is independent of the lapse function f(r). (orig.)

  8. High efficiency single frequency 355 nm all-solid-state UV laser

    International Nuclear Information System (INIS)

    Xie, Xiaobing; Wei, Daikang; Ma, Xiuhua; Li, Shiguang; Liu, Jiqiao; Zhu, Xiaolei; Chen, Weibiao

    2016-01-01

    A novel conductively cooled high energy single-frequency 355 nm all-solid-state UV laser is presented based on sum-frequency mixing technique. In this system, a pulsed seeder laser at 1064 nm wavelength, modulated by an AOM, is directly amplified by the cascaded multi-stage hybrid laser amplifiers, and two LBO crystals are used for the SHG and SFG, finally a maximum UV pulse energy of 226 mJ at 355 nm wavelength is achieved with frequency-tripled conversion efficiency as high as 55%, the pulse width is around 12.2 ns at the repetition frequency of 30 Hz. The beam quality factor M 2 of the output UV laser is measured to be 2.54 and 2.98 respectively in two orthogonal directions. (paper)

  9. In-situ nanoelectrospray for high-throughput screening of enzymes and real-time monitoring of reactions.

    Science.gov (United States)

    Yang, Yuhan; Han, Feifei; Ouyang, Jin; Zhao, Yunling; Han, Juan; Na, Na

    2016-01-01

    The in-situ and high-throughput evaluation of enzymes and real-time monitoring of enzyme catalyzed reactions in liquid phase is quite significant in the catalysis industry. In-situ nanoelectrospray, the direct sampling and ionization method for mass spectrometry, has been applied for high-throughput evaluation of enzymes, as well as the on-line monitoring of reactions. Simply inserting a capillary into a liquid system with high-voltage applied, analytes in liquid reaction system can be directly ionized at the capillary tip with small volume consumption. With no sample pre-treatment or injection procedure, different analytes such as saccharides, amino acids, alkaloids, peptides and proteins can be rapidly and directly extracted from liquid phase and ionized at the capillary tip. Taking irreversible transesterification reaction of vinyl acetate and ethanol as an example, this technique has been used for the high-throughput evaluation of enzymes, fast optimizations, as well as real-time monitoring of reaction catalyzed by different enzymes. In addition, it is even softer than traditional electrospray ionization. The present method can also be used for the monitoring of other homogenous and heterogeneous reactions in liquid phases, which will show potentials in the catalysis industry. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. CMS High Level Trigger Timing Measurements

    International Nuclear Information System (INIS)

    Richardson, Clint

    2015-01-01

    The two-level trigger system employed by CMS consists of the Level 1 (L1) Trigger, which is implemented using custom-built electronics, and the High Level Trigger (HLT), a farm of commercial CPUs running a streamlined version of the offline CMS reconstruction software. The operational L1 output rate of 100 kHz, together with the number of CPUs in the HLT farm, imposes a fundamental constraint on the amount of time available for the HLT to process events. Exceeding this limit impacts the experiment's ability to collect data efficiently. Hence, there is a critical need to characterize the performance of the HLT farm as well as the algorithms run prior to start up in order to ensure optimal data taking. Additional complications arise from the fact that the HLT farm consists of multiple generations of hardware and there can be subtleties in machine performance. We present our methods of measuring the timing performance of the CMS HLT, including the challenges of making such measurements. Results for the performance of various Intel Xeon architectures from 2009-2014 and different data taking scenarios are also presented. (paper)

  11. FPGA cluster for high-performance AO real-time control system

    Science.gov (United States)

    Geng, Deli; Goodsell, Stephen J.; Basden, Alastair G.; Dipper, Nigel A.; Myers, Richard M.; Saunter, Chris D.

    2006-06-01

    Whilst the high throughput and low latency requirements for the next generation AO real-time control systems have posed a significant challenge to von Neumann architecture processor systems, the Field Programmable Gate Array (FPGA) has emerged as a long term solution with high performance on throughput and excellent predictability on latency. Moreover, FPGA devices have highly capable programmable interfacing, which lead to more highly integrated system. Nevertheless, a single FPGA is still not enough: multiple FPGA devices need to be clustered to perform the required subaperture processing and the reconstruction computation. In an AO real-time control system, the memory bandwidth is often the bottleneck of the system, simply because a vast amount of supporting data, e.g. pixel calibration maps and the reconstruction matrix, need to be accessed within a short period. The cluster, as a general computing architecture, has excellent scalability in processing throughput, memory bandwidth, memory capacity, and communication bandwidth. Problems, such as task distribution, node communication, system verification, are discussed.

  12. Oregon's On-Time High School Graduation Rate Shows Strong Growth in 2014-15. Research Brief

    Science.gov (United States)

    Oregon Department of Education, 2016

    2016-01-01

    Oregon continues to make gains in its on-time high school graduation rate. The rate increased to 74% for the 2014-15 school year--up from 72% the year before. The graduation rate for almost all student groups rose, led by Hispanic students (2.4 percentage points) and Black students (2.4 percentage points). The rate for economically disadvantaged…

  13. Education for All: High Expectations or False Hopes?

    Science.gov (United States)

    Hallak, Jacques

    Although the World Conference on Education for All, held in March 1990 in Jomtien, Thailand, fostered international consensus on educational goals and raised expectations, obstacles to successful achievement of education for all (EFA) must be identified. This paper describes the five most important obstacles--political factors, economic/financial…

  14. Highly flexible, all solid-state micro-supercapacitors from vertically aligned carbon nanotubes.

    Science.gov (United States)

    Hsia, Ben; Marschewski, Julian; Wang, Shuang; In, Jung Bin; Carraro, Carlo; Poulikakos, Dimos; Grigoropoulos, Costas P; Maboudian, Roya

    2014-02-07

    We report a highly flexible planar micro-supercapacitor with interdigitated finger electrodes of vertically aligned carbon nanotubes (VACNTs). The planar electrode structures are patterned on a thin polycarbonate substrate with a facile, maskless laser-assisted dry transfer method. Sputtered Ni is used to reduce the in-plane resistance of the VACNT electrodes. An ionogel, an ionic liquid in a semi-solid matrix, is used as an electrolyte to form a fully solid-state device. We measure a specific capacitance of 430 μF cm(-2) for a scan rate of 0.1 V s(-1) and achieve rectangular cyclic voltammograms at high scan rates of up to 100 V s(-1). Minimal change in capacitance is observed under bending. Mechanical fatigue tests with more than 1000 cycles confirm the high flexibility and durability of the novel material combination chosen for this device. Our results indicate that this scalable and facile fabrication technique shows promise for application in integrated energy storage for all solid-state flexible microdevices.

  15. High accurate time system of the Low Latitude Meridian Circle.

    Science.gov (United States)

    Yang, Jing; Wang, Feng; Li, Zhiming

    In order to obtain the high accurate time signal for the Low Latitude Meridian Circle (LLMC), a new GPS accurate time system is developed which include GPS, 1 MC frequency source and self-made clock system. The second signal of GPS is synchronously used in the clock system and information can be collected by a computer automatically. The difficulty of the cancellation of the time keeper can be overcomed by using this system.

  16. Adolescent Views of Time Management: Rethinking the School Day in Junior High School

    Science.gov (United States)

    Strom, Paris S.; Strom, Robert D.; Sindel-Arrington, Tricia

    2016-01-01

    Junior high school presents a significant increase in time demands both for study and for social relationships. The students (N = 240) in grades 7 and 8 at a junior high school anonymously completed online the Time Management Poll concerning their own use of time and the way their school managed time. The 20 items in the poll allowed them to…

  17. National Rates of Uterine Rupture are not Associated with Rates of Previous Caesarean Delivery

    DEFF Research Database (Denmark)

    Colmorn, Lotte B.; Langhoff-Roos, Jens; Jakobsson, Maija

    2017-01-01

    % of all Nordic deliveries. Information on the comparison population was retrieved from the national medical birth registers. Incidence rate ratios by previous caesarean delivery and intended mode of delivery after caesarean were modelled using Poisson regression. RESULTS: The incidence of uterine rupture......BACKGROUND: Previous caesarean delivery and intended mode of delivery after caesarean are well-known individual risk factors for uterine rupture. We examined if different national rates of uterine rupture are associated with differences in national rates of previous caesarean delivery and intended...... was 7.8/10 000 in Finland and 4.6/10 000 in Denmark. Rates of caesarean (21.3%) and previous caesarean deliveries (11.5%) were highest in Denmark, while the rate of intended vaginal delivery after caesarean was highest in Finland (72%). National rates of uterine rupture were not associated...

  18. Human Papilloma Virus Identification in Breast Cancer Patients with Previous Cervical Neoplasia.

    Science.gov (United States)

    Lawson, James S; Glenn, Wendy K; Salyakina, Daria; Clay, Rosemary; Delprado, Warick; Cheerala, Bharathi; Tran, Dinh D; Ngan, Christopher C; Miyauchi, Shingo; Karim, Martha; Antonsson, Annika; Whitaker, Noel J

    2015-01-01

    Women with human papilloma virus (HPV)-associated cervical neoplasia have a higher risk of developing breast cancer than the general female population. The purpose of this study was to (i) identify high-risk HPVs in cervical neoplasia and subsequent HPV positive breast cancers which developed in the same patients and (ii) determine if these HPVs were biologically active. A range of polymerase chain reaction and immunohistochemical techniques were used to conduct a retrospective cohort study of cervical precancers and subsequent breast cancers in the same patients. The same high-risk HPV types were identified in both the cervical and breast specimens in 13 (46%) of 28 patients. HPV type 18 was the most prevalent. HPVs appeared to be biologically active as demonstrated by the expression of HPV E7 proteins and the presence of HPV-associated koilocytes. The average age of these patients diagnosed with breast cancer following prior cervical precancer was 51 years, as compared to 60 years for all women with breast cancer (p for difference = 0.001). These findings indicate that high-risk HPVs can be associated with cervical neoplasia and subsequent young age breast cancer. However, these associations are unusual and are a very small proportion of breast cancers. These outcomes confirm and extend the observations of two similar previous studies and offer one explanation for the increased prevalence of serious invasive breast cancer among young women.

  19. Human papilloma virus identification in breast cancer patients with previous cervical neoplasia

    Directory of Open Access Journals (Sweden)

    James Sutherland Lawson

    2016-01-01

    Full Text Available Purpose: Women with human papilloma virus (HPV associated cervical neoplasia have a higher risk of developing breast cancer than the general female population. The purpose of this study was to (i identify high risk for cancer HPVs in cervical neoplasia and subsequent HPV positive breast cancers which developed in the same patients and (ii determine if these HPVs were biologically active.Methods: A range of polymerase chain reaction (PCR and immunohistochemical techniques were used to conduct a retrospective cohort study of cervical precancers and subsequent breast cancers in the same patients. Results: The same high risk HPV types were identified in both the cervical and breast specimens in 13 (46% of 28 patients. HPV type 18 was the most prevalent. HPVs appeared to be biologically active as demonstrated by the expression of HPV E7 proteins and the presence of HPV associated koilocytes. The average age of these patients diagnosed with breast cancer following prior cervical precancer was 51 years, as compared to 60 years for all women with breast cancer (p for difference = 0.001. Conclusions: These findings indicate that high risk HPVs can be associated with cervical neoplasia and subsequent young age breast cancer. However these associations are unusual and are a very small proportion of breast cancers. These outcomes confirm and extend the observations of 2 similar previous studies and offer one explanation for the increased prevalence of serious invasive breast cancer among young women.

  20. Influence of previous experience on resistance training on reliability of one-repetition maximum test.

    Science.gov (United States)

    Ritti-Dias, Raphael Mendes; Avelar, Ademar; Salvador, Emanuel Péricles; Cyrino, Edilson Serpeloni

    2011-05-01

    The 1-repetition maximum test (1RM) has been widely used to assess maximal strength. However, to improve accuracy in assessing maximal strength, several sessions of the 1RM test are recommended. The aim of this study was to analyze the influence of previous resistance training experience on the reliability of 1RM test. Thirty men were assigned to the following 2 groups according to their previous resistance training experience: no previous resistance training experience (NOEXP) and more than 24 months of resistance training experience (EXP). All subjects performed the 1RM tests in bench press and squat in 4 sessions on distinct days. There was a significant session × group effect in bench press (F = 3.09; p reliability of the 1RM test is influenced by the subject's previous experience in resistance training. Subjects without experience in resistance training require more practice and familiarization and show greater increases in maximal strength between sessions than subjects with previous experience in resistance training.

  1. Substance use among medical students in Barcelona (Spain). A comparison with previous surveys.

    Science.gov (United States)

    Rodriguez, M E; Cami, J

    1986-11-01

    During the academic year 1983-1984, a survey on drug consumption was conducted among medical students in Barcelona. There was a high proportion of smokers in both sexes. Alcohol consumption was four times higher among men than women; high proof beverages were becoming the most common drinks. Coffee was the caffeine drink consumed by almost the whole population studied. Although cannabis derivatives had been tried at least once by almost all the students, regular consumers were almost non-existent. Amphetamine consumption was restricted to examination periods. The use of opiates, cocaine, hallucinogens, and solvents was rare for the sample. Results from this study are compared with those from similar surveys conducted 5 and 10 years ago.

  2. Parent-adolescent joint projects involving leisure time and activities during the transition to high school.

    Science.gov (United States)

    Marshall, Sheila K; Young, Richard A; Wozniak, Agnieszka; Lollis, Susan; Tilton-Weaver, Lauree; Nelson, Margo; Goessling, Kristen

    2014-10-01

    Leisure research to date has generally overlooked planning and organizing of leisure time and activities between parents and adolescents. This investigation examined how a sample of Canadian adolescents and their parents jointly constructed and acted on goals related to adolescents' leisure time during the move from elementary to high school. Using the Qualitative Action-Project Method, data were collected over an 8-10 month period from 26 parent-adolescent dyads located in two urban sites, through video-taped conversations about leisure time, video recall interviews, and telephone monitoring interviews. Analysis of the data revealed that the joint projects of the 26 dyads could be grouped into three clusters: a) governance transfer or attempts to shift, from parent to adolescent, responsibility over academic demands, organizing leisure time, and safety with peers, b) balancing extra-curricular activities with family life, academics, and social activities, and c) relationship adjustment or maintenance. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  3. Time evolution of the vacuum - pair production in high intensity laser fields

    Energy Technology Data Exchange (ETDEWEB)

    Woellert, Anton; Bauke, Heiko; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2013-07-01

    Interaction between the vacuum and high intensity lasers will lead to new possibilities in high-field physics. We present numerical ab initio studies for time evolution of the vacuum state into multiple pair states. The high intensity laser field of two counter-propagating beams is treated classically and in the non-perturbative regime (E{sub 0}/ω ∝ 1). In this regime, the time needed by an electron to become relativistic in presence of a static field E{sub 0} is of same order as the period of the laser field. Pair state probabilities as well as correlations are investigated in real-time depending on polarization and field strength.

  4. Pile-up Rejection in the High Granularity Time Detector for the High Luminosity LHC

    CERN Document Server

    McNulty, Paul

    2016-01-01

    The High Granularity Timing Detector, a proposed upgrade to the Liquid Argon Calorimeter during the transition to the High Luminosity LHC, will provide increased resolution in the time domain and offer an avenue for efficiently mitigating the expected increase in pile-up jets. This study analyzes how effectively current algorithms are using a signal jet peak calculation to disentangle desired information from other events. Two samples, one with only hard-scattering events and another that also included pile-up events, were used. A transverse momentum range of 30GeV to 70GeV and pseudo-rapidity range of 2.4 to 4.8 divided the sample to see how the HGTD performed when calculating the signal peak for each jet and how many cells had detections in and out of that peak for each sample.

  5. High-Resolution Near Real-Time Drought Monitoring in South Asia

    Science.gov (United States)

    Aadhar, S.; Mishra, V.

    2017-12-01

    Drought in South Asia affect food and water security and pose challenges for millions of people. For policy-making, planning and management of water resources at the sub-basin or administrative levels, high-resolution datasets of precipitation and air temperature are required in near-real time. Here we develop a high resolution (0.05 degree) bias-corrected precipitation and temperature data that can be used to monitor near real-time drought conditions over South Asia. Moreover, the dataset can be used to monitor climatic extremes (heat waves, cold waves, dry and wet anomalies) in South Asia. A distribution mapping method was applied to correct bias in precipitation and air temperature (maximum and minimum), which performed well compared to the other bias correction method based on linear scaling. Bias-corrected precipitation and temperature data were used to estimate Standardized precipitation index (SPI) and Standardized Precipitation Evapotranspiration Index (SPEI) to assess the historical and current drought conditions in South Asia. We evaluated drought severity and extent against the satellite-based Normalized Difference Vegetation Index (NDVI) anomalies and satellite-driven Drought Severity Index (DSI) at 0.05˚. We find that the bias-corrected high-resolution data can effectively capture observed drought conditions as shown by the satellite-based drought estimates. High resolution near real-time dataset can provide valuable information for decision-making at district and sub- basin levels.

  6. Highly compressible and all-solid-state supercapacitors based on nanostructured composite sponge.

    Science.gov (United States)

    Niu, Zhiqiang; Zhou, Weiya; Chen, Xiaodong; Chen, Jun; Xie, Sishen

    2015-10-21

    Based on polyaniline-single-walled carbon nanotubes -sponge electrodes, highly compressible all-solid-state supercapacitors are prepared with an integrated configuration using a poly(vinyl alcohol) (PVA)/H2 SO4 gel as the electrolyte. The unique configuration enables the resultant supercapacitors to be compressed as an integrated unit arbitrarily during 60% compressible strain. Furthermore, the performance of the resultant supercapacitors is nearly unchanged even under 60% compressible strain. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Leisure-time and commuting physical activity and high blood pressure: the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Treff, C; Benseñor, I M; Lotufo, P A

    2017-04-01

    This study investigates the association between leisure-time physical activity and commuting-related physical activity and high blood pressure among participants in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil). Physical activity was assessed through application of the International Physical Activity Questionnaire, particularly the domains addressing leisure and transportation. We used the World Health Organization's definition (⩾150 min per week of moderate activities or 75 min per week of vigorous activities) to establish three categories: active, insufficiently active and inactive. Hypertension was defined as systolic/diastolic blood pressure of >140/90 mm Hg or use of antihypertensive medications. From a universe of 15 105 participants, we analysed 13 857 subjects without previous cardiovascular diseases. The association between physical activity and hypertension was obtained using Poisson regression with adjustment for age, race, education, income, body mass index, diabetes and sodium and alcohol intake. Men who were active during leisure time had a multivariate prevalence ratio (95% confidence interval) of 0.84 (0.77-0.92) for hypertension compared with inactive men. For women, the prevalence ratio of active vs inactive during leisure time was 0.86 (0.79-0.95). However, this protective effect of leisure-time physical activity was not observed among men and women with diabetes or obese women. The association found between commuting-related physical activity and hypertension was not detected among men, and the prevalence ratio for women who were active during commuting time compared with inactive women was 1.11 (1.01-1.21). In conclusion, leisure-time physical activity was protective against hypertension, and commuting-related physical activity was associated with high blood pressure among women.

  8. Outcomes after radical prostatectomy in men receiving previous pelvic radiation for non-prostate malignancies.

    Science.gov (United States)

    Masterson, Timothy A; Wedmid, Alexei; Sandhu, Jaspreet S; Eastham, James A

    2009-08-01

    To report the perioperative and functional outcomes of nine patients treated at our institution who had radical prostatectomy (RP) after previous pelvic radiotherapy (RT) for non-prostate malignancies. From 1993 to 2007, nine patients had RP after external beam RT for testicular seminoma (six), anorectal cancer (two) and colon cancer (one). Clinical information was obtained from a prospective prostate cancer database. RP was completed with no identifiable injury to adjacent structures in all nine patients. Four patients had significant pelvic fibrosis, and three required bilateral neurovascular bundle (NVB) resection. The NVB was preserved in the remaining six patients, four with good preoperative erectile function. However, no patient recovered erectile function after RP at a median (range) follow-up of 75 (12-172) months. Of seven men continent before RP, four required one or fewer pads daily and three were completely dry, achieving complete urinary control at a median (range) time of 7.5 (2-20) months. Two patients developed an anastomotic stricture, one being associated with concomitant ureteric stricture. RP after pelvic RT for non-prostate malignancies was not associated with increased intraoperative morbidity. However, rates of anastomotic stricture, erectile dysfunction and urinary incontinence appeared to be higher than those reported after RP in men with no previous RT, and comparable with those seen in the salvage RP setting.

  9. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  10. High Performance Embedded System for Real-Time Pattern Matching

    CERN Document Server

    Sotiropoulou, Calliope Louisa; The ATLAS collaboration; Gkaitatzis, Stamatios; Citraro, Saverio; Giannetti, Paola; Dell'Orso, Mauro

    2016-01-01

    We present an innovative and high performance embedded system for real-time pattern matching. This system is based on the evolution of hardware and algorithms developed for the field of High Energy Physics (HEP) and more specifically for the execution of extremely fast pattern matching for tracking of particles produced by proton-proton collisions in hadron collider experiments. A miniaturized version of this complex system is being developed for pattern matching in generic image processing applications. The design uses the flexibility of Field Programmable Gate Arrays (FPGAs) and the powerful Associative Memory Chip (ASIC) to achieve real-time performance. The system works as a contour identifier able to extract the salient features of an image. It is based on the principles of cognitive image processing, which means that it executes fast pattern matching and data reduction mimicking the operation of the human brain.

  11. Value of time: Speeding behavior and gasoline prices

    OpenAIRE

    Wolff, Hendrik

    2012-01-01

    Do drivers reduce speeds when gasoline prices are high? Previous research investigating this energy conservation hypothesis produced mixed results. We take a fresh look at the data and estimate a significant negative relationship between speeding and gasoline prices. This presents a new methodology of deriving the 'Value of Time' (VOT) based on the intensive margin (previous VOT studies compare across the extensive margin) which has important advantages to circumvent potential omitted variabl...

  12. Obesity in pediatric ALL survivors: a meta-analysis.

    Science.gov (United States)

    Zhang, Fang Fang; Kelly, Michael J; Saltzman, Edward; Must, Aviva; Roberts, Susan B; Parsons, Susan K

    2014-03-01

    Previous studies of survivors of pediatric acute lymphoblastic leukemia (ALL) have drawn heterogeneous conclusions regarding the prevalence of obesity and risk factors for developing obesity in pediatric ALL survivors. We sought to determine the prevalence of obesity in pediatric ALL survivors and examine risk factors for obesity through a systematic review and meta-analysis. A MEDLINE search was performed from its inception through 2013. Studies met the inclusion criteria if they (1) included at least 10 survivors of pediatric ALL; (2) assessed the prevalence or indicators of obesity; and (3) compared obesity among ALL survivors to a reference population or external control group. Extracted data included patient and treatment characteristics, study design, population used for comparison, and prevalence of obesity. Forty-seven studies met the inclusion criteria. Despite significant heterogeneity among the studies (I(2) = 96%), the mean BMI z score in 1742 pediatric ALL survivors was 0.83 (95% confidence interval: 0.60-1.06), which corresponds to the 80th BMI percentile, indicating a significantly higher BMI in pediatric ALL survivors than the reference population. Subgroup analyses found a high prevalence of obesity in ALL survivors regardless of survivors' receipt of cranial irradiation, gender, or age at diagnosis. Obesity is prevalent in pediatric ALL survivors and is independent of patient- and treatment-related characteristics. Clinicians need to screen for obesity and its associated health conditions early in survivorship.

  13. Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii

    Directory of Open Access Journals (Sweden)

    Linke Sonja

    2006-01-01

    Full Text Available Abstract Background Coxiella burnetii, the bacterium causing Q fever, is an obligate intracellular biosafety level 3 agent. Detection and quantification of these bacteria with conventional methods is time consuming and dangerous. During the last years, several PCR based diagnostic assays were developed to detect C. burnetii DNA in cell cultures and clinical samples. We developed and evaluated TaqMan-based real-time PCR assays that targeted the singular icd (isocitrate dehydrogenase gene and the transposase of the IS1111a element present in multiple copies in the C. burnetii genome. Results To evaluate the precision of the icd and IS1111 real-time PCR assays, we performed different PCR runs with independent DNA dilutions of the C. burnetii Nine Mile RSA493 strain. The results showed very low variability, indicating efficient reproducibility of both assays. Using probit analysis, we determined that the minimal number of genome equivalents per reaction that could be detected with a 95% probability was 10 for the icd marker and 6.5 for the IS marker. Plasmid standards with cloned icd and IS1111 fragments were used to establish standard curves which were linear over a range from 10 to 107 starting plasmid copy numbers. We were able to quantify cell numbers of a diluted, heat-inactivated Coxiella isolate with a detection limit of 17 C. burnetii particles per reaction. Real-time PCR targeting both markers was performed with DNA of 75 different C. burnetii isolates originating from all over the world. Using this approach, the number of IS1111 elements in the genome of the Nine Mile strain was determined to be 23, close to 20, the number revealed by genome sequencing. In other isolates, the number of IS1111 elements varied widely (between seven and 110 and seemed to be very high in some isolates. Conclusion We validated TaqMan-based real-time PCR assays targeting the icd and IS1111 markers of C. burnetii. The assays were shown to be specific, highly

  14. Effects of Part-Time Work on School Achievement During High School

    Science.gov (United States)

    Singh, Kusum; Chang, Mido; Dika, Sandra

    2007-01-01

    The authors explored the effects of part-time work on school achievement during high school. To estimate the true effects of part-time work on school grades, the authors included family background, students' educational aspirations, and school engagement as controls. Although a substantial literature exists on the relationship of part-time work…

  15. COMPREHENSIVE PHOTOMETRIC HISTORIES OF ALL KNOWN GALACTIC RECURRENT NOVAE

    International Nuclear Information System (INIS)

    Schaefer, Bradley E.

    2010-01-01

    I collect virtually all photometry of the 10 known galactic recurrent novae (RNe) and their 37 known eruptions. This consists of my modern measures of nearly all archival plates (providing the only data for half of 37 known eruptions), my own 10,000 CCD magnitudes from 1987 to present (providing virtually all of the magnitudes in quiescence for seven RNe), over 140,000 visual magnitude estimates recorded by amateur astronomers (who discovered half the known eruptions), and the small scattering of magnitudes from all the literature. From this, I produce various uniform products: (1) BVRIJHK comparison star magnitudes and BV comparison star sequences to cover the entire range of eruption; (2) complete light curves for all eruptions; (3) best-fit B and V light curve templates; (4) orbital periods for all but one RN; (5) exhaustive searches for all missed eruptions; (6) measured discovery efficiencies since 1890; (7) true recurrence time scales; (8) predicted next eruption dates; (9) variations on time scales of minutes, hours, days, months, years, decades, and century; (10) uniform distances and extinctions to all RNe; (11) BV colors at peak and UBVRIJHK colors at minimum, all with extinction corrections; and (12) the spectral energy distributions over UBVRIJHK. Highlights of this work include the discoveries of one new RN, six previously unknown eruptions, and the orbital periods for half the RNe. The goal of this work is to provide uniform demographics for answering questions like the 'What is the death rate of RNe in our Galaxy?' and 'Are the white dwarfs gaining or losing mass over each eruption cycle?.' An important use of this work is for the question of whether RNe can be the progenitors of Type Ia supernovae.

  16. Real time thermal hydraulic model for high temperature gas-cooled reactor core

    International Nuclear Information System (INIS)

    Sui Zhe; Sun Jun; Ma Yuanle; Zhang Ruipeng

    2013-01-01

    A real-time thermal hydraulic model of the reactor core was described and integrated into the simulation system for the high temperature gas-cooled pebble bed reactor nuclear power plant, which was developed in the vPower platform, a new simulation environment for nuclear and fossil power plants. In the thermal hydraulic model, the helium flow paths were established by the flow network tools in order to obtain the flow rates and pressure distributions. Meanwhile, the heat structures, representing all the solid heat transfer elements in the pebble bed, graphite reflectors and carbon bricks, were connected by the heat transfer network in order to solve the temperature distributions in the reactor core. The flow network and heat transfer network were coupled and calculated in real time. Two steady states (100% and 50% full power) and two transients (inlet temperature step and flow step) were tested that the quantitative comparisons of the steady results with design data and qualitative analysis of the transients showed the good applicability of the present thermal hydraulic model. (authors)

  17. High rate, fast timing Glass RPC for the high ${\\eta}$ CMS muon detectors

    CERN Document Server

    Lagarde, F.; Laktineh, I.; Buridon, V.; Chen, X.; Combaret, C.; Eynard, A.; Germani, L.; Grenier, G.; Mathez, H.; Mirabito, L.; Petrukhin, A.; Steen, A.; Tromeur, W.; Wang, Y.; Gong, A.; Moreau, N.; de la Taille, C.; Dulucq, F.; Cimmino, A.; Crucy, S.; Fagot, A.; Gul, M.; Rios, A.A.O.; Tytgat, M.; Zaganidis, N.; Aly, S.; Assran, Y.; Radi, A.; Sayed, A.; Singh, G.; Abbrescia, M.; Iaselli, G.; Maggi, M.; Pugliese, G.; Verwilligen, P.; Van Doninck, W.F.; Colafranceschi, S.; Sharmag, A.; Benussi, L.; Bianco, S.; Piccolo, D.; Primavera, F.; Bhatnagar, V.; Kumari, R.; Mehta, A.; Singh, J.; Ahmad, A.; Ahmed, W.; Asghar, M.I.; Awan, I.M.; Hoorani, R.; Muhammad, S.; Shahzad, H.; Shah, M.A.; Cho, S.W.; Choi, S.Y.; Hong, B.; Kang, M.H.; Lee, K.S.; Lim, J.H.; Park, S.K.; Kim, M.S.; Carpinteyro Bernardino, S.; Pedraza, I.; Uribe Estradam, C.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pant, L.M.; Buontempo, S.; Cavallo, N.; Esposito, M.; Fabozzi, F.; Lanza, G.; Orso, I.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Thyssen, F.; Braghieri, A.; Magnani, A.; Montagna, P.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Ban, Y.; Qian, S.J.; Choi, M.; Choi, Y.; Goh, J.; Kim, D.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Bagaturia, I.; Lomidze, D.; Avila, C.; Cabrera, A.; Sanabria, J.C.; Crotty, I.; Vaitkus, J.

    2016-09-09

    The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|{\\eta}| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high ${\\eta}$ muon stations of CMS. First the design of small size prototypes and studies of their perfor...

  18. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure.

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56-30.80) mm, corneal diameter was 14.71±1.07 (13.0-16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9-1.0), and IOP was 39.5±5.7 (30-55) mmHg. The mean follow-up time was 18.29±10.96 (5-44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pvalve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications.

  19. Real-time haptic cutting of high-resolution soft tissues.

    Science.gov (United States)

    Wu, Jun; Westermann, Rüdiger; Dick, Christian

    2014-01-01

    We present our systematic efforts in advancing the computational performance of physically accurate soft tissue cutting simulation, which is at the core of surgery simulators in general. We demonstrate a real-time performance of 15 simulation frames per second for haptic soft tissue cutting of a deformable body at an effective resolution of 170,000 finite elements. This is achieved by the following innovative components: (1) a linked octree discretization of the deformable body, which allows for fast and robust topological modifications of the simulation domain, (2) a composite finite element formulation, which thoroughly reduces the number of simulation degrees of freedom and thus enables to carefully balance simulation performance and accuracy, (3) a highly efficient geometric multigrid solver for solving the linear systems of equations arising from implicit time integration, (4) an efficient collision detection algorithm that effectively exploits the composition structure, and (5) a stable haptic rendering algorithm for computing the feedback forces. Considering that our method increases the finite element resolution for physically accurate real-time soft tissue cutting simulation by an order of magnitude, our technique has a high potential to significantly advance the realism of surgery simulators.

  20. 49 CFR 173.23 - Previously authorized packaging.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Previously authorized packaging. 173.23 Section... REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Preparation of Hazardous Materials for Transportation § 173.23 Previously authorized packaging. (a) When the regulations specify a packaging with a specification marking...

  1. Determinants of Part-Time Work of High School Seniors.

    Science.gov (United States)

    Hotchkiss, Lawrence

    1986-01-01

    Assesses effects on student part-time employment outcomes of personal characteristics (i.e., gender, race) and institutional characteristics (i.e., vocational high school, participation in cooperative education). Reports that supply theory explains student employment outcomes better than demand theory. (CH)

  2. High School Students' Time Management Skills in Relation to Research Anxiety

    Science.gov (United States)

    Akcoltekin, Alpturk

    2015-01-01

    This study aimed to determine the opinions of high school students relating to time management and present a correlation of their time management skills with demographic variables, as well as examining the relation between their level of research anxiety and time management skills. The study group composed 270 12th-grade students (127 males and…

  3. High-performance flat-panel solar thermoelectric generators with high thermal concentration.

    Science.gov (United States)

    Kraemer, Daniel; Poudel, Bed; Feng, Hsien-Ping; Caylor, J Christopher; Yu, Bo; Yan, Xiao; Ma, Yi; Wang, Xiaowei; Wang, Dezhi; Muto, Andrew; McEnaney, Kenneth; Chiesa, Matteo; Ren, Zhifeng; Chen, Gang

    2011-05-01

    The conversion of sunlight into electricity has been dominated by photovoltaic and solar thermal power generation. Photovoltaic cells are deployed widely, mostly as flat panels, whereas solar thermal electricity generation relying on optical concentrators and mechanical heat engines is only seen in large-scale power plants. Here we demonstrate a promising flat-panel solar thermal to electric power conversion technology based on the Seebeck effect and high thermal concentration, thus enabling wider applications. The developed solar thermoelectric generators (STEGs) achieved a peak efficiency of 4.6% under AM1.5G (1 kW m(-2)) conditions. The efficiency is 7-8 times higher than the previously reported best value for a flat-panel STEG, and is enabled by the use of high-performance nanostructured thermoelectric materials and spectrally-selective solar absorbers in an innovative design that exploits high thermal concentration in an evacuated environment. Our work opens up a promising new approach which has the potential to achieve cost-effective conversion of solar energy into electricity. © 2011 Macmillan Publishers Limited. All rights reserved

  4. 22 CFR 40.91 - Certain aliens previously removed.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Certain aliens previously removed. 40.91... IMMIGRANTS UNDER THE IMMIGRATION AND NATIONALITY ACT, AS AMENDED Aliens Previously Removed § 40.91 Certain aliens previously removed. (a) 5-year bar. An alien who has been found inadmissible, whether as a result...

  5. Homicide and domestic violence. Are there different psychological profiles mediated by previous exerted on the victim?

    OpenAIRE

    Montserrat Yepes; Maria R. Vinas; Inmaculada Armadans; Miguel A. Soria

    2009-01-01

    A sample of 46 men was evaluated with the DAPP (Questionnaire of Domestic Aggressor Psychological Profile). All were inmates convicted for various degrees of violence against their wives in different prisons. The sample was divided into three groups: homicides without previous violence against their wives (H) (n=11), homicides with previous violence (VH) (n=9) and domestic batterers without previous homicide attempts against their partners (B) (n=26). The aim of the study was to analyze the p...

  6. Impulsivity moderates the relationship between previous quit failure and cue-induced craving.

    Science.gov (United States)

    Erblich, Joel; Michalowski, Alexandra

    2015-12-01

    Poor inhibitory control has been shown to be an important predictor of relapse to a number of drugs, including nicotine. Indeed, smokers who exhibit higher levels of impulsivity are thought to have impaired regulation of urges to smoke, and previous research has suggested that impulsivity may moderate cue-induced cigarette cravings. To that end, we conducted a study to evaluate the interplay between failed smoking cessation, cue-induced craving, and impulsivity. Current smokers (n=151) rated their cigarette cravings before and after laboratory to exposure to smoking cues, and completed questionnaires assessing impulsivity and previous failed quit attempts. Findings indicated that shorter duration of previous failed quit attempts was related to higher cue-induced cigarette craving, especially among smokers with higher levels of impulsivity. Results underscore the importance of considering trait impulsivity as a factor in better understanding the management of cue-induced cravings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Time-adjusted variable resistor

    Science.gov (United States)

    Heyser, R. C.

    1972-01-01

    Timing mechanism was developed effecting extremely precisioned highly resistant fixed resistor. Switches shunt all or portion of resistor; effective resistance is varied over time interval by adjusting switch closure rate.

  8. Spatio-spectral analysis of ionization times in high-harmonic generation

    Energy Technology Data Exchange (ETDEWEB)

    Soifer, Hadas, E-mail: hadas.soifer@weizmann.ac.il [Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 76100 (Israel); Dagan, Michal; Shafir, Dror; Bruner, Barry D. [Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 76100 (Israel); Ivanov, Misha Yu. [Department of Physics, Imperial College London, South Kensington Campus, SW7 2AZ London (United Kingdom); Max-Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, Max-Born-Strasse 2A, D-12489 Berlin (Germany); Serbinenko, Valeria; Barth, Ingo; Smirnova, Olga [Max-Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, Max-Born-Strasse 2A, D-12489 Berlin (Germany); Dudovich, Nirit [Department of Physics of Complex Systems, Weizmann Institute of Science, Rehovot 76100 (Israel)

    2013-03-12

    Graphical abstract: A spatio-spectral analysis of the two-color oscillation phase allows us to accurately separate short and long trajectories and reconstruct their ionization times. Highlights: ► We perform a complete spatio-spectral analysis of the high harmonic generation process. ► We analyze the ionization times across the entire spatio-spectral plane of the harmonics. ► We apply this analysis to reconstruct the ionization times of both short and long trajectories. - Abstract: Recollision experiments have been very successful in resolving attosecond scale dynamics. However, such schemes rely on the single atom response, neglecting the macroscopic properties of the interaction and the effects of using multi-cycle laser fields. In this paper we perform a complete spatio-spectral analysis of the high harmonic generation process and resolve the distribution of the subcycle dynamics of the recolliding electron. Specifically, we focus on the measurement of ionization times. Recently, we have demonstrated that the addition of a weak, crossed polarized second harmonic field allows us to resolve the moment of ionization (Shafir, 2012) [1]. In this paper we extend this measurement and perform a complete spatio-spectral analysis. We apply this analysis to reconstruct the ionization times of both short and long trajectories showing good agreement with the quantum path analysis.

  9. Influence of previous breast surgery in sentinel lymph node biopsy in patients with breast cancer.

    Science.gov (United States)

    López-Prior, V; Díaz-Expósito, R; Casáns Tormo, I

    The aim of this study was to review the feasibility of selective sentinel lymph node biopsy in patients with previous surgery for breast cancer, as well as to examine the factors that may interfere with sentinel node detection. A retrospective review was performed on 91 patients with breast cancer and previous breast surgery, and who underwent sentinel lymph node biopsy. Patients were divided into two groups according to their previous treatment: aesthetic breast surgery in 30 patients (group I) and breast-conserving surgery in 61 (group II). Lymphoscintigraphy was performed after an intra-tumour injection in 21 cases and a peri-areolar injection in 70 cases. An analysis was made of lymphatic drainage patterns and overall sentinel node detection according to clinical, pathological and surgical variables. The overall detection of the sentinel lymph node in the lymphoscintigraphy was 92.3%, with 7.7% of extra-axillary drainages. The identification rate was similar after aesthetic breast surgery (93.3%) and breast-conserving surgery (91.8%). Sentinel lymph nodes were found in the contralateral axilla in two patients (2.2%), and they were included in the histopathology study. The non-identification rate in the lymphoscintigraphy was 7.7%. There was a significantly higher non-detection rate in the highest histological grade tumours (28.6% grade III, 4.5% grade I and 3.6% grade II). Sentinel lymph node biopsy in patients with previous breast surgery is feasible and deserves further studies to assess the influence of different aspects in sentinel node detection in this clinical scenario. A high histological grade was significantly associated with a lower detection. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  10. Mutations in Genes Encoding Cardiac Ion Channels Previously Associated With Sudden Infant Death Syndrome (SIDS) Are Present With High Frequency in New Exome Data

    DEFF Research Database (Denmark)

    Andreasen, Charlotte Hartig; Refsgaard, Lena; Nielsen, Jonas B

    2013-01-01

    National Heart, Lung, and Blood Institute Grand Opportunity (NHLBI GO) Exome Sequencing Project (ESP) provided important knowledge on genetic variation in the background population. Our aim was to identify all variants previously associated with SIDS in ESP to improve the discrimination between plausible......Sudden infant death syndrome (SIDS) is the leading cause of death in the first 6 months after birth in the industrialized world. The genetic contribution to SIDS has been investigated intensively and to date, 14 cardiac channelopathy genes have been associated with SIDS. Newly published data from...

  11. All-phase MR angiography using independent component analysis of dynamic contrast enhanced MRI time series. φ-MRA

    International Nuclear Information System (INIS)

    Suzuki, Kiyotaka; Matsuzawa, Hitoshi; Watanabe, Masaki; Nakada, Tsutomu; Nakayama, Naoki; Kwee, I.L.

    2003-01-01

    Dynamic contrast enhanced magnetic resonance imaging (dynamic MRI) represents a MRI version of non-diffusible tracer methods, the main clinical use of which is the physiological construction of what is conventionally referred to as perfusion images. The raw data utilized for constructing MRI perfusion images are time series of pixel signal alterations associated with the passage of a gadolinium containing contrast agent. Such time series are highly compatible with independent component analysis (ICA), a novel statistical signal processing technique capable of effectively separating a single mixture of multiple signals into their original independent source signals (blind separation). Accordingly, we applied ICA to dynamic MRI time series. The technique was found to be powerful, allowing for hitherto unobtainable assessment of regional cerebral hemodynamics in vivo. (author)

  12. High Channel Count Time-to-Digital Converter and Lasercom Processor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — High-channel-count, high-precision, and high-throughput time-to-digital converters (TDC) are needed to support detector arrays used in deep-space optical...

  13. TV viewing time is associated with increased all-cause mortality in Brazilian adults independent of physical activity.

    Science.gov (United States)

    Turi, B C; Monteiro, H L; Lemes, Í R; Codogno, J S; Lynch, K R; Asahi Mesquita, C A; Fernandes, R A

    2018-02-01

    The purpose of this study was to investigate the association between television (TV) viewing and all-cause mortality among Brazilian adults after 6 years of follow-up. This longitudinal study started in 2010 in the city of Bauru, SP, Brazil, and involved 970 adults aged ≥50 years. Mortality was reported by relatives and confirmed in medical records of the Brazilian National Health System. Physical activity (PA) and TV viewing were assessed by the Baecke questionnaire. Health status, sociodemographic and behavioral covariates were considered as potential confounders. After 6 years of follow-up, 89 deaths were registered (9.2% [95% CI=7.4%-11%]). Type 2 diabetes mellitus was associated with higher risk of mortality (P-value=.012). Deaths correlated significantly with age (ρ=.188; P-value=.001), overall PA score (ρ=-.128; P-value=.001) and TV viewing (ρ=.086; P-value=.007). Lower percentage of participants reported TV viewing time as often (16%) and very often (5.7%), but there was an association between higher TV viewing time ("often" and "very often" grouped together) and increased mortality after 6 years of follow-up (P-value=.006). The higher TV viewing time was associated with a 44.7% increase in all-cause mortality (HR=1.447 [1.019-2.055]), independently of other potential confounders. In conclusion, the findings from this cohort study identified increased risk of mortality among adults with higher TV viewing time, independently of PA and other variables. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. High short-circuit current density CdTe solar cells using all-electrodeposited semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Echendu, O.K., E-mail: oechendu@yahoo.com; Fauzi, F.; Weerasinghe, A.R.; Dharmadasa, I.M.

    2014-04-01

    CdS/CdTe and ZnS/CdTe n–n heterojunction solar cells have been fabricated using all-electrodeposited semiconductors. The best devices show remarkable high short-circuit current densities of 38.5 mAcm{sup −2} and 47.8 mAcm{sup −2}, open-circuit voltages of 630 mV and 646 mV and conversion efficiencies of 8.0% and 12.0% respectively. The major strength of these device structures lies in the combination of n–n heterojunction with a large Schottky barrier at the n-CdTe/metal back contact which provides the required band bending for the separation of photo-generated charge carriers. This is in addition to the use of a high quality n-type CdTe absorber layer with high electron mobility. The potential barrier heights estimated for these devices from the current–voltage characteristics exceed 1.09 eV and 1.13 eV for CdS/CdTe and ZnS/CdTe cells respectively. The diode rectification factors of both devices are in excess of four orders of magnitude with reverse saturation current densities of 1.0 × 10{sup −7} Acm{sup −2} and 4.0 × 10{sup −7} Acm{sup −2} respectively. These all-electrodeposited solar cell device structures are currently being studied and developed as an alternative to the well-known p–n junction structures which utilise chemical bath-deposited CdS. The preliminary material growth, device fabrication and assessment results are presented in this paper. - Highlights: • Two-electrode deposition. • High J{sub sc} Schottky barrier solar cells. • CdCl{sub 2} + CdF{sub 2} treatment.

  15. Regarding the rejection performance of a polymeric reverse osmosis membrane for the final purification of two-phase olive mill effluents previously treated by an advanced oxidation process

    International Nuclear Information System (INIS)

    Ochando-Pulido, J.M.; Martínez-Férez, A.

    2017-01-01

    In previous works on olive mill wastewater (OMW), secondary advanced oxidation treatment solved the problem related to the presence of phenolic compounds and considerable chemical oxygen demand. However, the effluent presented a significant salinity after this treatment. In this work, an adequate operation of a reverse osmosis (RO) membrane is addressed to ensure constant performance over a long period of time. In this paper, the effect of the operating parameters on the dynamic membrane rejection performance towards the target species was examined and discussed. Rejection efficiencies of all species were observed to follow a similar pattern, which consisted of slight initial improvement that further decreased over time. Rejection of both divalent ions remained constant at over 99% regardless of the operating conditions. Rejections were noticed to follow the order SO42−> Cl−> NO3− and Ca2+> Mg2+> K+> Na+, as a rule. Divalent species were moderately more highly rejected than monovalent ones, in accordance with their higher charge and molecular size, and sulfate anions were consistently rejected by over 99%. Finally, the RO membrane exiting treated effluent was depleted of the high electro conductivity initially present (above 97% rejection), permitting its re-use as good quality irrigation water (below 1 mS/cm). [es

  16. A high time resolution x-ray diagnostic on the Madison Symmetric Torus

    Science.gov (United States)

    DuBois, Ami M.; Lee, John David; Almagri, Abdulgadar F.

    2015-07-01

    A new high time resolution x-ray detector has been installed on the Madison Symmetric Torus (MST) to make measurements around sawtooth events. The detector system is comprised of a silicon avalanche photodiode, a 20 ns Gaussian shaping amplifier, and a 500 MHz digitizer with 14-bit sampling resolution. The fast shaping time diminishes the need to restrict the amount of x-ray flux reaching the detector, limiting the system dead-time. With a much higher time resolution than systems currently in use in high temperature plasma physics experiments, this new detector has the versatility to be used in a variety of discharges with varying flux and the ability to study dynamics on both slow and fast time scales. This paper discusses the new fast x-ray detector recently installed on MST and the improved time resolution capabilities compared to the existing soft and hard x-ray diagnostics. In addition to the detector hardware, improvements to the detector calibration and x-ray pulse identification software, such as additional fitting parameters and a more sophisticated fitting routine are discussed. Finally, initial data taken in both high confinement and standard reversed-field pinch plasma discharges are compared.

  17. Time dependence of magnetization of high temperature superconductors

    International Nuclear Information System (INIS)

    Larkin, A.I.; Geshkenbein, V.B.

    1988-10-01

    Magnetization of high T c superconductors logarithmically decreases with time. There is a maximum in the temperature dependence of the coefficient at this logarithm. If one assumes that there do exist two kinds of pinning centers, then this dependence can be described in the Anderson theory of thermal creeps of Abrikosov's vortices. The temperature dependence of the critical current is also discussed. (author). 23 refs

  18. High Time-Resolution 640-Gb/s Clock Recovery Using Time-Domain Optical Fourier Transformation and Narrowband Optical Filter

    DEFF Research Database (Denmark)

    Guan, P.; Mulvad, Hans Christian Hansen; Kasai, K.

    2010-01-01

    We present a novel scheme for subharmonic clock recovery from an optical time-division-multiplexing signal using time-domain optical Fourier transformation and a narrowband optical filter. High-resolution 640-Gb/s clock recovery is successfully demonstrated with no pattern dependence. The clock...

  19. The necessity of Darwin: this journal's tribute to the most influential scientist of all time.

    Science.gov (United States)

    Sessions, Stanley K; Macgregor, Herbert C

    2009-01-01

    Charles Darwin is considered by many to be one of the most influential scientists of all time. His theory of evolution via natural selection was astonishingly prescient in terms of what modern biology has revealed in the 150 years since the publication of The Origin of Species, especially since Darwin was unaware of even the most fundamental aspects of transmission genetics, not to mention molecular biology. Here we speculate what impact it would have had on Darwin's thinking if he had known what we now know about molecular biology and cytogenetics.

  20. Unidirectional Wave Vector Manipulation in Two-Dimensional Space with an All Passive Acoustic Parity-Time-Symmetric Metamaterials Crystal

    Science.gov (United States)

    Liu, Tuo; Zhu, Xuefeng; Chen, Fei; Liang, Shanjun; Zhu, Jie

    2018-03-01

    Exploring the concept of non-Hermitian Hamiltonians respecting parity-time symmetry with classical wave systems is of great interest as it enables the experimental investigation of parity-time-symmetric systems through the quantum-classical analogue. Here, we demonstrate unidirectional wave vector manipulation in two-dimensional space, with an all passive acoustic parity-time-symmetric metamaterials crystal. The metamaterials crystal is constructed through interleaving groove- and holey-structured acoustic metamaterials to provide an intrinsic parity-time-symmetric potential that is two-dimensionally extended and curved, which allows the flexible manipulation of unpaired wave vectors. At the transition point from the unbroken to broken parity-time symmetry phase, the unidirectional sound focusing effect (along with reflectionless acoustic transparency in the opposite direction) is experimentally realized over the spectrum. This demonstration confirms the capability of passive acoustic systems to carry the experimental studies on general parity-time symmetry physics and further reveals the unique functionalities enabled by the judiciously tailored unidirectional wave vectors in space.