WorldWideScience

Sample records for preventing total beam

  1. Total skin electron beam therapy for cutaneous lymphomas and leukemias

    International Nuclear Information System (INIS)

    Nisce, L.Z.; Chu, F.C.H.; Lee, H.S.; Filippa, D.; Kempin, S.; Coleman, M.

    1982-01-01

    Total skin electron beam therapy (TSEB) was used in the treatment of 33 patients with lymphoma and 13 patients with leukemia involving extensive segments of the skin surface. Twenty-two of 23 had lesions as a primary manifestation of lymphoma (primary cutaneous lymphoma-PCL) and 11 developed cutaneous lesions following disseminated nodal lymphoma (secondary cutaneous lymphoma-SCL). A once weekly fractionation scheme was employed to irradiate the entire skin surface with 3.5 to 4 MeV electron beam from a 6 MeV linear accelerator. During each weekly session, 400 rad were delivered to the entire skin and a complete course consisted of 4-6 consecutive weekly sessions. The majority of patients have been previously treated elsewhere for various periods and all patients have been at risk for a median of 12 months, range from 12-117 months following TSEB. Striking predominance of the diffuse pattern (76%) was demonstrated in both the PCL and SCL. There was extracutaneous involvement in 63% (13/22) of the PCL, nodal or visceral at onset of TSEB; median follow-up was 24 months, range 6-117 months; 20/22 (90%) of all patients obtained prompt relief of symptoms and complete regression of cutaneous lesions. Duration of cutaneous remission ranged from 6-96 months, median 18 months; in general, duration was adversly influenced by the presence of visceral involvement at onset of TSEB. Although cutaneous response among the patients with SCL and leukemia was equally good, many of these patients were treated for palliation because of rapid progression of their disease. Once weekly treatments were highly effective, well-tolerated and no untoward immediate or late effects have been noted in the bone marrow or normal skin irradiated

  2. Total skin electron beam therapy in mycosis fungoides

    International Nuclear Information System (INIS)

    Terashima, Hiromi; Yamashita, Shigeru; Ishino, Yohichi; Suenaga, Yoshinori

    1988-01-01

    The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author)

  3. Prevention of heterotopic ossification after total hip replacement with NSAIDs

    NARCIS (Netherlands)

    Fijn, R; Koorevaar, RT; Brouwers, JRBJ

    Introduction: non steroidal anti-inflammatory drugs ( NSAIDs) and prophylactic radiotherapy can prevent ectopic bone formation around the hip after total hip arthroplasty. Methods: We retrieved from Medline, Embase and the Cochrane Register ( clinical) trials and other relevant literature on the

  4. Measurements of effective total macroscopic cross sections and effective energy of continuum beam

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisao [Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy

    1998-03-01

    Two practically useful quantities are introduced in this study to characterize a continuum neutron beam and to describe transmission phenomena of the beam in field of quantitative neutron radiography: an effective energy instead of a peak energy or a mean energy of the spectrum and an effective total macroscopic (ETM) cross section instead of a total macroscopic (TM) cross section defined at the monochromatic energy. The effective energy was evaluated by means of energy dependence of ETM cross section. To realize the method a beam quality indicator (BQI) has been proposed recently. Several effective energies were measured for non-filtered, filtered neutron beams, and outputs of neutron guide tubes in world by the BQI. A thermal neutron beam and three beams modulated by Pb filters with different thicknesses are studied to measure ETM cross sections for various materials and summarized in a table. Validity of the effective energy determined by the BQI is discussed relating with ETM cross sections of materials. (author)

  5. Extending DIII-D Neutral Beam Modulated Operations with a Camac Based Total on Time Interlock

    International Nuclear Information System (INIS)

    Baggest, D.S.; Broesch, J.D.; Phillips, J.C.

    1999-01-01

    A new total-on-time interlock has increased the operational time limits of the Neutral Beam systems at DIII-D. The interlock, called the Neutral Beam On-Time-Limiter (NBOTL), is a custom built CAMAC module utilizing a Xilinx 9572 Complex Programmable Logic Device (CPLD) as its primary circuit. The Neutral Beam Injection Systems are the primary source of auxiliary heating for DIII-D plasma discharges and contain eight sources capable of delivering 20MW of power. The delivered power is typically limited to 3.5 s per source to protect beam-line components, while a DIII-D plasma discharge usually exceeds 5 s. Implemented as a hardware interlock within the neutral beam power supplies, the NBOTL limits the beam injection time. With a continuing emphasis on modulated beam injections, the NBOTL guards against command faults and allows the beam injection to be safely spread over a longer plasma discharge time. The NBOTL design is an example of incorporating modern circuit design techniques (CPLD) within an established format (CAMAC). The CPLD is the heart of the NBOTL and contains 90% of the circuitry, including a loadable, 1 MHz, 28 bit, BCD count down timer, buffers, and CAMAC communication circuitry. This paper discusses the circuit design and implementation. Of particular interest is the melding of flexible modern programmable logic devices with the CAMAC format

  6. The perceptibility of variations in total x-ray beam filtration as evidenced on radiographs

    International Nuclear Information System (INIS)

    Williamson, B.D.P.

    1983-01-01

    The use of filtration in the primary x-ray beam has long been a standard procedure in controlling radiation doses to patients in diagnostic radiology, particularly surface doses. For lightly filtered beams, the addition of further filtration effectively removes softer beam components which otherwise would be absorbed within the patient. The amount and quality of radiation reaching the film is changed only slightly. Thus the first increments of filtration added to diagnostic x-ray beams require little or no change in exposure factors. With further filtration, however, the penetration of the beam increases and a greater proportion is transmitted through the patient to the film. The image contrast is reduced. Simultaneously the useful beam intensity is reduced to the extent that compensating mAs increases begin to be required to maintain constant optical density in the radiograph. When these compensatory adjustments are made it is possible to examine the relationship between total filtration and its effects on radiographic appearance, which should be seen as variations in contrast or penetration. This report is of an exploratory study of the perceptibility to radiographers of these changes in radiographic appearance caused by variations in x-ray beam filtration. (auth)

  7. Influence of total beam current on HRTEM image resolution in differentially pumped ETEM with nitrogen gas.

    Science.gov (United States)

    Bright, A N; Yoshida, K; Tanaka, N

    2013-01-01

    Environmental transmission electron microscopy (ETEM) enables the study of catalytic and other reaction processes as they occur with Angstrom-level resolution. The microscope used is a dedicated ETEM (Titan ETEM, FEI Company) with a differential pumping vacuum system and apertures, allowing aberration corrected high-resolution transmission electron microscopy (HRTEM) imaging to be performed with gas pressures up to 20 mbar in the sample area and with significant advantages over membrane-type E-cell holders. The effect on image resolution of varying the nitrogen gas pressure, electron beam current density and total beam current were measured using information limit (Young's fringes) on a standard cross grating sample and from silicon crystal lattice imaging. As expected, increasing gas pressure causes a decrease in HRTEM image resolution. However, the total electron beam current also causes big changes in the image resolution (lower beam current giving better resolution), whereas varying the beam current density has almost no effect on resolution, a result that has not been reported previously. This behavior is seen even with zero-loss filtered imaging, which we believe shows that the drop in resolution is caused by elastic scattering at gas ions created by the incident electron beam. Suitable conditions for acquiring high resolution images in a gas environment are discussed. Lattice images at nitrogen pressures up to 16 mbar are shown, with 0.12 nm information transfer at 4 mbar. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A Total Pleural Covering for Lymphangioleiomyomatosis Prevents Pneumothorax Recurrence.

    Directory of Open Access Journals (Sweden)

    Masatoshi Kurihara

    Full Text Available Spontaneous pneumothorax is a major and frequently recurrent complication of lymphangioleiomyomatosis (LAM. Despite the customary use of pleurodesis to manage pnenumothorax, the recurrence rate remains high, and accompanying pleural adhesions cause serious bleeding during subsequent lung transplantation. Therefore, we have developed a technique of total pleural covering (TPC for LAM to wrap the entire visceral pleura with sheets of oxidized regenerated cellulose (ORC mesh, thereby reinforcing the affected visceral pleura and preventing recurrence.Since January 2003, TPC has been applied during video-assisted thoracoscopic surgery for the treatment of LAM. The medical records of LAM patients who had TPC since that time and until August 2014 are reviewed.TPC was performed in 43 LAM patients (54 hemithoraces, 11 of whom required TPC bilaterally. Pneumothorax recurred in 14 hemithoraces (25.9% from 11 patients (25.6% after TPC. Kaplan-Meier estimates of recurrence-free hemithorax were 80.8% at 2.5 years, 71.7% at 5 years, 71.7% at 7.5 years, and 61.4% at 9 years. The recurrence-free probability was significantly better when 10 or more sheets of ORC mesh were utilized for TPC (P = 0.0018. TPC significantly reduced the frequency of pneumothorax: 0.544 ± 0.606 episode/month (mean ± SD before TPC vs. 0.008 ± 0.019 after TPC (P<0.0001. Grade IIIa postoperative complications were found in 13 TPC surgeries (24.1%.TPC successfully prevented the recurrence of pneumothorax in LAM, was minimally invasive and rarely caused restrictive ventilatory impairment.

  9. Proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.H.; Kycia, T.F.

    1978-03-01

    A PWC system was developed and extensively used in precision measurements of total cross sections at low momenta (0.4 to 1.1 GeV/c) and at high momenta (23 to 370 GeV/c). This ''electronic collimator'' operated simultaneously in a fast (250 nsec) decision making mode, and a slower (0.5 msec) readout mode. The decision making mode utilized adjustable hard-wired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events were read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure

  10. Effect of total cementitious content on shear strength of high-volume fly ash concrete beams

    International Nuclear Information System (INIS)

    Arezoumandi, Mahdi; Volz, Jeffery S.; Ortega, Carlos A.; Myers, John J.

    2013-01-01

    Highlights: ► Existing design standards conservatively predicted the capacity of the HVFAC beams. ► In general, the HVFAC beams exceeded the code predicted shear strengths. ► The cementitious content did not have effect on the shear behavior of the HVFAC beams. - Abstract: The production of portland cement – the key ingredient in concrete – generates a significant amount of carbon dioxide. However, due to its incredible versatility, availability, and relatively low cost, concrete is the most consumed manmade material on the planet. One method of reducing concrete’s contribution to greenhouse gas emissions is the use of fly ash to replace a significant amount of the cement. This paper compares two experimental studies that were conducted to investigate the shear strength of full-scale beams constructed with high-volume fly ash concrete (HVFAC) – concrete with at least 50% of the cement replaced with fly ash. The primary difference between the two studies involved the amount of cementitious material, with one mix having a relatively high total cementitious content (502 kg/m 3 ) and the other mix having a relatively low total cementitious content (337 kg/m 3 ). Both mixes utilized a 70% replacement of portland cement with a Class C fly ash. Each of these experimental programs consisted of eight beams (six without shear reinforcing and two with shear reinforcing in the form of stirrups) with three different longitudinal reinforcement ratios. The beams were tested under a simply supported four-point loading condition. The experimental shear strengths of the beams were compared with both the shear provisions of selected standards (US, Australia, Canada, Europe, and Japan) and a shear database of conventional concrete (CC) specimens. Furthermore, statistical data analyses (both parametric and nonparametric) were performed to evaluate whether or not there is any statistically significant difference between the shear strength of both mixes. Results of these

  11. RAPD analysis of Arabidopsis thaliana transferred with total DNA of cabbage by ion beam

    International Nuclear Information System (INIS)

    Bian Po; Yu Zengliang; Qin Guangyong; Huo Yuping; Wang Yan

    2003-01-01

    Two mutants were found among the Arabidopsis thaliana transferred with total DNA of cabbage. Variation of genome of T6 and its offspring were analyzed by RAPD-PCR with 40 random primers. The result from S168 primer was different from the CK, indicating that variation of genome can be made by total DNA transferring by use of ion beam, and this variation is hereditary. It is found that S 168-1850 is included within the gene of ABC transporter by aligning with genome of Arabidopsis thaliana in TAIT

  12. Dose characteristics of total-skin electron-beam irradiation with six-dual electron fields

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1998-01-01

    To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated. The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of Target-Skin Distance (TSD) and full collimator size (35x35 cm 2 on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cmx105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. The Full Width at Half Maximum(FWHM) of dose profile was 130 cm in large field of 105x105 cm 2 . The width of 100±10% of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose uniformity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80% depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within±10% difference excepts the protruding area of skin which needs a

  13. Utilization of thermoluminescent dosimetry in total skin electron beam radiotherapy of mycosis fungoides

    International Nuclear Information System (INIS)

    Antolak, John A.; Cundiff, Jackson H.; Ha, Chul S.

    1998-01-01

    Purpose: The purpose of this report is to discuss the utilization of thermoluminescent dosimetry (TLD) in total skin electron beam (TSEB) radiotherapy to: (a) compare patient dose distributions for similar techniques on different machines, (b) confirm beam calibration and monitor unit calculations, (c) provide data for making clinical decisions, and (d) study reasons for variations in individual dose readings. Methods and Materials: We report dosimetric results for 72 cases of mycosis fungoides, using similar irradiation techniques on two different linear accelerators. All patients were treated using a modified Stanford 6-field technique. In vivo TLD was done on all patients, and the data for all patients treated on both machines was collected into a database for analysis. Means and standard deviations (SDs) were computed for all locations. Scatter plots of doses vs. height, weight, and obesity index were generated, and correlation coefficients with these variables were computed. Results: The TLD results show that our current TSEB implementation is dosimetrically equivalent to the previous implementation, and that our beam calibration technique and monitor unit calculation is accurate. Correlations with obesity index were significant at several sites. Individual TLD results allow us to customize the boost treatment for each patient, in addition to revealing patient positioning problems and/or systematic variations in dose caused by patient variability. The data agree well with previously published TLD results for similar TSEB techniques. Conclusion: TLD is an important part of the treatment planning and quality assurance programs for TSEB, and routine use of TLD measurements for TSEB is recommended

  14. Total cross section measurement of radioactive isotopes with a thin beam neutron spectrometer

    International Nuclear Information System (INIS)

    Razbudej, V.F.; Vertebnyj, V.P.; Padun, G.S.; Muravitskij, A.V.

    1975-01-01

    The method for measuring the neutron total cross sections of radioactive isotopes by a time-of-flight spectrometer with a narrow (0.17 mm in diameter) beam of thermal neutrons is described. The distinguishing feature of this method is the use of capillary samples with a small amount of substance (0.05-1.0 mg). The energy range is 0.01-0.3 eV. The total cross sections of irradiated samples of sub(153)Eu and sub(151)Eu are measured. From them are obtained the cross sections of sub(152)Eu (Tsub(1/2)=12.4 g) and of sub(154)E (Tsub(1/2)=8.6 yr); they equal 11400+-1400 and 1530+-190 barn at E=0.0253 eV. The cross section of the sub(152)Eu absorption for the thermal spectrum (T=333 K) is determined by the activation method; it is 8900+-1200 barn

  15. Effect of dietary poly unsaturated fatty acids on total brain lipid concentration and anxiety levels of electron beam irradiated mice

    International Nuclear Information System (INIS)

    Suchetha Kumari; Bekal, Mahesh

    2013-01-01

    The whole brain irradiation causes injury to the nervous system at various levels. Omega-3 poly unsaturated fatty acids are very much essential for the growth and development of nervous system. Dietary supplementation of these nutrients will promote the development of injured neuronal cells. Therefore this study was undertaken to establish the role of Omega-3 poly unsaturated fatty acids on total brain lipid concentration, lipid peroxidation and anxiety levels in the irradiated mice. The effect of Electron Beam Radiation (EBR) on total brain lipid concentration, lipid peroxidation and anxiety level were investigated in male Swiss albino mice. The study groups were subjected to a sub-lethal dose of EBR and also the flax seed extract and fish oil were given orally to the irradiated mice. Irradiated groups show significant elevation in anxiety levels when compared to control group, indicating the acute radiation effects on the central nervous system. But the oral supplementation of dietary PUFA source decrees the anxiety level in the irradiated group. The analysis of lipid peroxidation showed a significant level of changes when compared between control and radiation groups. Dietary PUFA supplementation showed a significant level of decrease in the lipid peroxidation in the irradiated groups. The observation of total lipids in brain shows decrease in concentration in the irradiated groups, the differences in the variables follow the similar patterns as of that the MDA levels. This study suggests that the dietary intake of PUFAs may help in prevention and recovery of the oxidative stress caused by radiation. (author)

  16. Determination of the total neutron cross section using average energy shift method for filtered neutron beam

    Directory of Open Access Journals (Sweden)

    О. О. Gritzay

    2016-12-01

    Full Text Available Development of the technique for determination of the total neutron cross sections from the measurements of sample transmission by filtered neutrons, scattered on hydrogen is described. One of the methods of the transmission determination TH52Cr from the measurements of 52Cr sample, using average energy shift method for filtered neutron beam is presented. Using two methods of the experimental data processing, one of which is presented in this paper (another in [1], there is presented a set of transmissions, obtained for different samples and for different measurement angles. Two methods are fundamentally different; therefore, we can consider the obtained processing results, using these methods as independent. In future, obtained set of transmissions is planned to be used for determination of the parameters E0, Гn and R/ of the resonance 52Cr at the energy of 50 keV.

  17. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. METHODS AND MATERIALS: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over ... or a very good partial response rate (skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  18. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  19. Treatment of mycosis fungoides with total skin electron beam: response and relapse by ethnicity and sex.

    Science.gov (United States)

    Hinds, Ginette A; Alhariri, Jihad; Klein, Rhonda Q; Wilson, Lynn D

    2013-10-01

    To determine whether clinical response to total skin electron beam (TSEB) and relapse after TSEB differs by ethnicity and sex. Retrospective chart review of 77 patients with mycosis fungoides (MF), treated with TSEB in 2002 to 2008 at Yale University School of Medicine, Departments of Dermatology and Therapeutic Radiology. Women had better odds of response to TSEB than men (OR=6.4; 95% CI, 1.45-28.5; P=0.01). No significant difference was observed in response to TSEB between white and black patients (OR=0.69; 95% CI, 0.16-2.91; P=0.62). When stratified by race and sex, in comparison with black females, all other groups had lower odds of complete response (CR) to TSEB: black males (OR=0.39; 95% CI, 0.002-0.70; P=0.03), white females (OR=0.24; 95% CI, 0.02-2.53; P=0.24), and white males (OR=0.06; 95% CI, 0.006-0.60; P=0.02). Clinical CR was significantly predicted by the duration of symptoms (OR=0.98; 95% CI, 0.97-0.99; P=0.01); and nearly significant by clinical stage; stage III to stage I (OR=0.17; 95% CI, 0.02-1.02; P=0.07). Adjuvant treatment, previous treatment, and time from diagnosis to treatment have no significant effect on CR to TSEB. There was no statistically significant association between relapse after treatment and race, sex, clinical stage, or symptom duration. The odds of achieving a CR to TSEB decrease when diagnosis of MF is delayed and when patients present with advanced-stage disease. Women with MF were more likely to have a CR to treatment, and this response was even more significant in black women.

  20. Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization

    International Nuclear Information System (INIS)

    Stsepankou, D; Arns, A; Hesser, J; Ng, S K; Zygmanski, P

    2012-01-01

    The objective of this paper is to evaluate an iterative maximum likelihood (ML) cone–beam computed tomography (CBCT) reconstruction with total variation (TV) regularization with respect to the robustness of the algorithm due to data inconsistencies. Three different and (for clinical application) typical classes of errors are considered for simulated phantom and measured projection data: quantum noise, defect detector pixels and projection matrix errors. To quantify those errors we apply error measures like mean square error, signal-to-noise ratio, contrast-to-noise ratio and streak indicator. These measures are derived from linear signal theory and generalized and applied for nonlinear signal reconstruction. For quality check, we focus on resolution and CT-number linearity based on a Catphan phantom. All comparisons are made versus the clinical standard, the filtered backprojection algorithm (FBP). In our results, we confirm and substantially extend previous results on iterative reconstruction such as massive undersampling of the number of projections. Errors of projection matrix parameters of up to 1° projection angle deviations are still in the tolerance level. Single defect pixels exhibit ring artifacts for each method. However using defect pixel compensation, allows up to 40% of defect pixels for passing the standard clinical quality check. Further, the iterative algorithm is extraordinarily robust in the low photon regime (down to 0.05 mAs) when compared to FPB, allowing for extremely low-dose image acquisitions, a substantial issue when considering daily CBCT imaging for position correction in radiotherapy. We conclude that the ML method studied herein is robust under clinical quality assurance conditions. Consequently, low-dose regime imaging, especially for daily patient localization in radiation therapy is possible without change of the current hardware of the imaging system. (paper)

  1. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  2. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos; Scobioala, Sergiu; Reinartz, Gabriele; Haverkamp, Uwe; Willich, Normann [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany); Weishaupt, Carsten [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Stadler, Rudolf [Department of Dermatology, Johannes-Wesling-Klinikum Minden, Minden (Germany); Sunderkötter, Cord [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany)

    2015-12-01

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit

  3. Multiple courses of high-dose total skin electron beam therapy in the management of mycosis fungoides

    International Nuclear Information System (INIS)

    Becker, Mark; Hoppe, Richard T.; Knox, Susan J.

    1995-01-01

    Purpose: A retrospective analysis was undertaken to determine the indications for, the efficacy of, and the long-term complications of two courses of total skin electron beam therapy for mycosis fungoides. Methods and Materials: A retrospective analysis of 15 patients with the pathologic diagnosis of mycosis fungoides treated in the Department of Radiation Oncology at Stanford University Medical Center between 1968 and 1990 was performed. All patients received two courses of high-dose electron beam therapy to the skin. The mean dose for the total skin treatment for the first course was 32.6 Gy and 23.4 Gy for the second course of treatment. Results: Following the first course of total skin electron beam therapy, 11 of 15 had a complete response, with a mean duration of 11.6 months. All patients received adjuvant therapies between the first and second courses of high-dose total skin electron beam therapy. The mean interval between the first and the second courses of therapy was 41.3 months. Patients were restaged prior to commencement of their second course of high-dose total skin electron beam therapy, resulting in upstaging in six. The second course of therapy resulted in six complete responses and nine partial responses. Twelve of these patients have since died, 1 is lost to follow-up, and 2 are living with disease. The long-term side effects in the two living patients include pigmentation changes, alopecia, and diffuse xerosis. Conclusion: Delivery of two courses of total skin electron beam therapy is technically feasible, tolerable, and efficacious. The dose to the total skin was reduced for the second course of therapy in all cases. The criteria used to screen patients included initial good response to total skin electron treatment, long disease-free interval, exhaustion of other therapeutic modalities, and generalized skin involvement at relapse. Long-term toxicities were mild in severity and generally consisted of generalized xerosis, scattered

  4. Preoperative radiotherapy (RT) for prevention of heterotopic ossification (HO) after total hip replacement

    International Nuclear Information System (INIS)

    Heyd, R.; Schopohl, B.; Boettcher, H.D.; Kirchner, J.

    1997-01-01

    Preliminary results of a prospective study which investigates the efficacy of preoperative radiotherapy (RT) for prevention of heterotopic ossification (HO) after total hip arthroplasty are summarized. A total number of 20 hip joints (18 patients) were irradiated with a single dose of 6.0 Gy Brooker grade II). The functional outcome quantified with the Harris score was improved by an average of 37.9 points. The authors conclude that preoperative RT is an effective alternative for postoperative irradiation. (orig.) [de

  5. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  6. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  7. Toward sensitive graphene nanoribbon-nanopore devices by preventing electron beam-induced damage.

    Science.gov (United States)

    Puster, Matthew; Rodríguez-Manzo, Julio A; Balan, Adrian; Drndić, Marija

    2013-12-23

    Graphene-based nanopore devices are promising candidates for next-generation DNA sequencing. Here we fabricated graphene nanoribbon-nanopore (GNR-NP) sensors for DNA detection. Nanopores with diameters in the range 2-10 nm were formed at the edge or in the center of graphene nanoribbons (GNRs), with widths between 20 and 250 nm and lengths of 600 nm, on 40 nm thick silicon nitride (SiN(x)) membranes. GNR conductance was monitored in situ during electron irradiation-induced nanopore formation inside a transmission electron microscope (TEM) operating at 200 kV. We show that GNR resistance increases linearly with electron dose and that GNR conductance and mobility decrease by a factor of 10 or more when GNRs are imaged at relatively high magnification with a broad beam prior to making a nanopore. By operating the TEM in scanning TEM (STEM) mode, in which the position of the converged electron beam can be controlled with high spatial precision via automated feedback, we were able to prevent electron beam-induced damage and make nanopores in highly conducting GNR sensors. This method minimizes the exposure of the GNRs to the beam before and during nanopore formation. The resulting GNRs with unchanged resistances after nanopore formation can sustain microampere currents at low voltages (∼50 mV) in buffered electrolyte solution and exhibit high sensitivity, with a large relative change of resistance upon changes of gate voltage, similar to pristine GNRs without nanopores.

  8. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields

    International Nuclear Information System (INIS)

    Pavon, Ester Carrasco; Sanchez-Doblado, Francisco; Leal, Antonio; Capote, Roberto; Lagares, Juan Ignacio; Perucha, Maria; Arrans, Rafael

    2003-01-01

    Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an essential first step towards TSET Monte Carlo (MC) verification. The non-standard 6 MeV 40 x 40 cm 2 electron beam at a source to surface distance (SSD) of 100 cm as well as its horizontal projection behind a polymethylmethacrylate (PMMA) screen to SSD = 380 cm were evaluated. The EGS4 OMEGA-BEAM code package running on a Linux home made 47 PCs cluster was used for the MC simulations. Percentage depth-dose curves and profiles were calculated and measured experimentally for the 40 x 40 cm 2 field at both SSD = 100 cm and patient surface SSD = 380 cm. The output factor (OF) between the reference 40 x 40 cm 2 open field and its horizontal projection as TSET beam at SSD = 380 cm was also measured for comparison with MC results. The accuracy of the simulated beam was validated by the good agreement to within 2% between measured relative dose distributions, including the beam characteristic parameters (R 50 , R 80 , R 100 , R p , E 0 ) and the MC calculated results. The energy spectrum, fluence and angular distribution at different stages of the beam (at SSD = 100 cm, at SSD = 364.2 cm, behind the PMMA beam spoiler screen and at treatment surface SSD = 380 cm) were derived from MC simulations. Results showed a final decrease in mean energy of almost 56% from the exit window to the treatment surface. A broader angular distribution (FWHM of the angular distribution increased from 13deg at SSD 100 cm to more than 30deg at the treatment surface) was fully attributable to the PMMA beam spoiler screen. OF calculations and measurements agreed to less than 1%. The effect of changing the electron energy cut-off from 0.7 MeV to 0.521 MeV and air density fluctuations in the bunker which could affect the MC results were shown to have a negligible impact on the beam fluence distributions. Results proved the applicability of using MC

  9. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  10. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A. (Lahey Clinic Medical Center, Burlington, MA (USA))

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.

  11. Dose measurements in the treatment of mycosis fungoides with total skin irradiation using a 4 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Poli, M.E.R. [Hospital Real e Benemerita Sociedade Portuguesa de Beneficencia (Brazil); Todo, A.S.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, CNEN/SP Travessa R, Sao Paulo (Brazil)

    2000-05-01

    The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the mycosis fungoides. The cure may be obtained in 10% to 40% of cases. The original Stanford University technique, created in 1960, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the apparatus. In this work we describe a 4 MeV electrons beam treatment method. We intend to improve the uniformity of the dose in the patient, as well, to reduce the problems with the overlapping treatment fields, that occurs in conventional treatment that uses 1 meter of focus-skin distance, and the treatment time to the patient. Only one modification was done in the apparatus: the dose rate for this treatment was doubled. The patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the gantry, with 60 degrees of interval between the rotations. In each position, the patient receives a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it). The dosimetric data obtained were compared to the international protocols (AAPM). The delivered doses in the patient were measured with thermoluminescent dosimeters placed on skin surface and with Kodak XV-2 films placed between different slabs of an anthropomorphic phantom. The dose distribution in the phantom shows a good uniformity, in all thickness of interest, so it is possible to use this technique in the treatment of the mycosis fungoides as well Kaposi's sarcoma. (author)

  12. A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chieh-Hsiu Jason; Aleman, Dionne M [Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, ON M5S 3G8 (Canada); Sharpe, Michael B, E-mail: chjlee@mie.utoronto.ca, E-mail: aleman@mie.utoronto.ca, E-mail: michael.sharpe@rmp.uhn.on.ca [Princess Margaret Hospital, Department of Radiation Oncology, University of Toronto, 610 University Avenue, Toronto, ON M5G 2M9 (Canada)

    2011-09-07

    The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beams must be used to cover a vastly larger treatment area than typical site-specific treatments (e.g., head-and-neck, prostate, etc). These complications result in excessively long computation times to develop IMRT treatment plans for TMI, so we attempt to develop methods that drastically reduce treatment planning time. We transform the BOO problem into the classical set cover problem (SCP) and use existing methods to solve SCP to obtain beam solutions. Although SCP is NP-Hard, our methods obtain beam solutions that result in quality treatments in minutes. We compare our approach to an integer programming solver for the SCP to illustrate the speed advantage of our approach.

  13. Total lymphoid irradiation prevents diabetes mellitus in the Bio-Breeding/Worcester (BB/W) rat

    International Nuclear Information System (INIS)

    Rossini, A.A.; Slavin, S.; Woda, B.A.; Geisberg, M.; Like, A.A.; Mordes, J.P.

    1984-01-01

    Total lymphoid irradiation (TLI) at doses of 2200 rads or greater prevented diabetes in susceptible BB/W rats. Two of 29 (7%) treated rats became diabetic compared with 23 of 39 (59%) controls. TLI did not, however, prevent insulitis or thyroiditis in nondiabetic rats, nor did it restore the depressed concanavalin-A responsiveness of BB rat lymphocytes. T-lymphocyte subset proportions were the same in both groups. TLI was associated with significant radiation-related mortality, and nondiabetic TLI-treated rats weighed significantly less than controls. It was concluded that TLI is effective in the prevention of BB rat diabetes. However, TLI fails to correct the subclinical immunologic abnormalities of the model and is associated with significant morbidity

  14. Hitachi advanced operating nuclear power plant total preventive maintenance management and service system

    International Nuclear Information System (INIS)

    Araki, Masamitsu; Jibu, Noboru; Abe, Kazuhiro

    1990-01-01

    The recent rate of operation of Japanese nuclear power stations attained the result exceeding 70 %, but in order to improve it further and maintain the high reliability, the preventive maintenance program of more elaborate and systematic must be planned and executed. However, in order to establish the plan for maintaining efficiently and with high accuracy the enormous machinery and equipment exceeding 60000 in a nuclear power station, the high advance by mechanization is indispensable. Therefore, Hitachi Ltd. has developed the total preventive maintenance system, and it has partially begun operation. This system has the function of the life diagnosis of machinery and equipment, in addition, it constructs the data base with the specifications of machinery and equipment, the history of checkup, the information on reliability in Japan and foreign countries and so on, and based on these information, the recommendation of checkup, the proposal of improving facilities and other items are to be summarized and offered to electric power companies. The preventive maintenance activities in Hitachi Ltd., the concept and the outline of the total preventive maintenance system are reported. (K.I.)

  15. Total glucosides of paeony prevents juxta-articular bone loss in experimental arthritis

    OpenAIRE

    Wei, Chen Chao; You, Fan Tian; Mei, Li Yu; Jian, Sun; Qiang, Chen Yong

    2013-01-01

    Background Total glucosides of paeony (TGP) is a biologically active compound extracted from Paeony root. TGP has been used in rheumatoid arthritis therapy for many years. However, the mechanism by which TGP prevents bone loss has been less explored. Methods TGP was orally administered for 3?months to New Zealand rabbits with antigen-induced arthritis (AIA). Digital x-ray knee images and bone mineral density (BMD) measurements of the subchondral knee bone were performed before sacrifice. Chon...

  16. Flowtron foot-pumps for prevention of venous thromboembolism in total hip and knee replacement.

    Science.gov (United States)

    Pitto, Rocco P; Koh, Chuan K

    2015-03-01

    Mechanical prophylaxis with foot-pumps provides an interesting alternative to chemical agents in the prevention of venous thomboembolism following major orthopaedic surgery procedures. The aim of this prospective study was to assess efficacy and safety of the Flowtron(®) foot-pumps system following total hip and knee replacement. The foot pumps were used as main tool for prevention of thromboembolic events, in most cases in association with a variety of chemicals. The primary endpoint of the study was to assess the incidence of deep vein thrombosis and pulmonary embolism after total hip and knee replacement. The secondary endpoints included postoperative bleeding, swelling, bruising and wound ooze. 424 consecutive patients were included in the study. Symptomatic deep vein thrombosis was detected in 7 patients (1.6%). All symptomatic deep vein thromboses were detected after discharge before the six week follow-up clinic. Five non-fatal pulmonary embolisms occurred (1.2%). Only one patient presented a major wound bleeding (0.2%). The mean difference of swelling of thigh pre-versus postoperatively was only 22.8 mm. In conclusion, thromboembolism prophylaxis after total hip and knee replacement using Flowtron(®) foot-pumps as main prevention tool of an individualised protocol appears effective and safe. This is the first clinical report related to this popular brand of foot pumps.

  17. Preventive and corrective maintenance for MINT EPS 3000 electron beam machine

    International Nuclear Information System (INIS)

    Siti Aiasah Hashim; Shaari Jahar

    2005-01-01

    Preventive and corrective maintenance of a high energy electron is to ensure that the machine would not fail during operation. MINT's EPS 3000 electron beam machine has been in operation for almost 12 years. Throughout those years, events relating to scheduled overhauls and unscheduled corrective maintenance had provided invaluable experience in the form of informal maintenance training to the operators. With the implementation of ISO 9001:2000 Quality Management System at the facility, the preventive and corrective maintenance program is becoming more structured and orderly. Collected maintenance data shall be used to initiate continual improvement activities in the facility.This paper describes MINT-ALURTRON's 12 years experience in providing maintenance work for the EPS 3000. (Author)

  18. Single-dose electron beam irradiation in treatment and prevention of keloids and hypertrophic scars

    International Nuclear Information System (INIS)

    Lo, T.C.M.; Salzman, F.A.; Seckel, B.R.; Wright, K.A.

    1990-01-01

    Low megavolt electron beam irradiation was used on 354 sites in 199 patients at Lahey Clinic either for palliation of symptomatic hypertrophic scars or as post operative irradiation in an attempt to prevent formation or recurrence of hypertrophic scars. Electron energies used ranged from 1.5 to 3.5 MeV. The median age of the 59 male patients was 22 years and of the 140 female patients 35 years. All patients had at least one follow-up visit, and the median follow-up was 35 months. Of the 294 sites treated for the first time, 272 (93 per cent) were irradiated with a single fraction with a skin dose ranging from 2 to 20 Gy. Of the 85 sites in 63 patients without excision of symptomatic hypertrophic scars, single-dose electron beam irradiation was of clinically significant value in only 41 sites (48 per cent). No patients have been treated without surgical excision since 1973. Because of a history of formation of hypertrophic scars elsewhere in the body, 13 patients with 19 incisions were treated prophylactically after operation for other diseases. All sites were irradiated with single doses ranging from 8 to 20 Gy, and hypertrophic scars did not subsequently develop in any patient. Altogether, 119 patients with 174 sites were irradiated after surgical excision of hypertrophic scars to prevent recurrence; 168 sites (97 per cent) received singe-fraction irradiation, and 161 received a dose of 8 Gy greater, up to 15 Gy. No statistically significant differences were observed in complete success rates, ranging from 82 to 90 per cent with doses of 9 Gy or greater. An interval of up to 72h between excision and single-fraction irradiation satisfactorily prevented recurrence, and clinically significant chronic telangiectasia was recorded in only one patient. Postoperative low megavolt electron beam irradiation with a single dose of 9 Gy or greater is highly effective in the prevention of formation recurrence of hypertrophic scars or keloids. (author). 31 refs.; 2 figs.; 4 tabs

  19. Total leukocyte and neutrophil count as preventive tools in reducing negative appendectomies.

    Science.gov (United States)

    Rafiq, Muhammad Salman; Khan, Mah Muneer; Khan, Ataullah; Ahmad, Bilal

    2015-03-01

    Negative appendectomies result in unnecessary admissions, health care burden, and cost. This study was conducted to assess total leukocyte and neutrophil counts as preventive tools in reducing negative appendectomies. Data of admitted patients who underwent appendectomies was analyzed. Receiver operator characteristic (ROC) curve analysis of total leukocyte and neutrophil counts was calculated for various cut-off points. Optimum sensitivity, specificity, overall accuracy, and area under the curve was determined. Of the four hundred and eightpatients, true and negative appendicitis by operative assessment was 294 (72.1%) and 114 (27.9%) compared to 311 (76.2%) and 97 (23.8%) by histopathology, respectively. Optimal cut-off for total leukocyte count was >11.9x10(9)/Liter with 87.14% sensitivity and 91.75% specificity. Optimal cut-off point for neutrophil count was >7.735x10(9)/Liter with 98.71% sensitivity and 91.75% specificity. Area under the curve for total leukocyte and neutrophil counts was 0.9603 and 0.9872, respectively with overall accuracy of 91.2% and 97.1%, respectively. Normal total leukocyte and neutrophil counts are strongly associated with negative appendectomies. Non-operative measures and careful observation of total leukocyte and neutrophil counts are of paramount importance.

  20. Total skin electron beam therapy for cutaneous T-cell lymphoma: a nationwide cohort study from Denmark

    DEFF Research Database (Denmark)

    Lindahl, Lise M; Kamstrup, Maria Rørbæk; Petersen, Peter M

    2011-01-01

    Background. Total skin electron beam therapy (TSEBT) is an effective palliative treatment for cutaneous T-cell lymphoma (CTCL). In the present study we reviewed the clinical response to TSEBT in Danish patients with CTCL. Material and methods. This retrospective study included 35 patients with CTCL......, the present study confirms that high-dose TSEBT is an effective, but generally not a curative therapy in the management of CTCL. High-dose treatment yielded significantly better results than low-dose treatment with 4 Gy. TSEBT offers significant palliation in most patients when other skin-directed or systemic...

  1. Indications for total cutaneous electron beam radiation therapy of mycosis fungoides

    International Nuclear Information System (INIS)

    Le Bourgeois, J.P.; Haddad, E.; Marinello, G.; Marin, L.; Mazeron, J.J.; Ganem, G.

    1987-01-01

    From 1977 to 1984, we treated 34 patients with mycosis fungoides and 9 patients with B cutaneous lymphomas. Eighteen patients with mycosis fungoides were treated with total skin electron irradiation (TSEI) and had a minimum follow-up of 15 months (range 15 months to 7 years). The lowest electron energy of the linear accelerator was 8 MeV therefore we placed a plexiglas screen between the patient and the machine; the resulting electron energy was 4 MeV. The total dose was 30 Gy delivered in 12 fractions over 40 days. There were 8 males and 10 females. The median age was 48 years (ranging from 13 to 78 years). All patients were staged as follows: Stage A = superficial lesions covering less than 50% of the body surface; Stage B = superficial lesions covering more than 50% of the body surface; Stage C = tumors involving the skin, lymph nodes and/or visceral organs. Five patients with Stage A (5/5) and 5 patients with Stage B (5/5) had a complete remission, 1 stage A patient relapsed 6 months after completion of treatment. All the Stage B patients recurred between 3 and 15 months. The recurrences were localized to the skin and were well controlled with topical nitrogen mustard or puvatherapy. Among the Stage C patients, 3 did not respond to treatment and died of their disease; the remaining 5 patients achieved complete remission but they all relapsed from 2 to 9 months following completion of treatment. The median follow-up was 32 months and the average time for relapse was 6.5 months. All relapses except one (15 months) occurred within the first year. We feel that total skin electron irradiation is indicated in Stage A and B patients. However, we feel Stage C patients should receive TSEI for palliative purposes only

  2. Total skin electron beam therapy as palliative treatment for cutaneous manifestations of advanced, therapy-refractory cutaneous lymphoma and leukemia

    International Nuclear Information System (INIS)

    Hauswald, Henrik; Zwicker, Felix; Rochet, Nathalie; Uhl, Matthias; Hensley, Frank; Debus, Jürgen; Herfarth, Klaus; Bischof, Marc

    2012-01-01

    To retrospectively access the outcome and toxicity of a total skin electron beam therapy (TSEBT) in patients with cutaneous lymphoma (CL) or leukemia. Treatment results of 25 patients (median age 63 years; 5 female, 20 male) with cutaneous manifestations of advanced and therapy-refractory CL (n = 21; T-cell lymphomas n = 18, B-cell lymphomas n = 3) stage IIB-IV or leukemia (n = 4; AML n = 2, CLL n = 1, PDC n = 1) treated between 1993 and 2010 were reviewed. All patients were symptomatic. The median total dose was 29Gy, applied in 29 fractions of median 1 Gy each. The median follow-up was 10 months. Palliation was achieved in 23 patients (92%). A clinical complete response was documented in 13 (52%) and a partial response in 10 patients (40%). The median time to skin progression was 5 months (range 1–18 months) and the actuarial one-year progression-free survival 35%. The median overall survival (OS) after the initiation of TSEBT was 10 months (range 1–46 months) and the actuarial one-year OS 45%. TSEBT related acute adverse events (grade 1 or 2) were observed in all patients during the treatment period. An acute grade 3 epitheliolysis developed in eight patients (32%). Long-term adverse events as a hyperpigmentation of the skin (grade 1 or 2) were documented in 19 patients (76%), and a hypohidrosis in seven patients (28%). For palliation of symptomatic cutaneous manifestations of advanced cutaneous lymphoma or leukemia, total skin electron beam therapy is an efficient and well tolerated considerable treatment option

  3. Cost of Radiotherapy Versus NSAID Administration for Prevention of Heterotopic Ossification After Total Hip Arthroplasty

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Chen, Sea S.; Shah, Anand P.; Coon, Alan B.; Dickler, Adam

    2008-01-01

    Purpose: Heterotopic ossification (HO), or abnormal bone formation, is a common sequela of total hip arthroplasty. This abnormal bone can impair joint function and must be surgically removed to restore mobility. HO can be prevented by postoperative nonsteroidal anti-inflammatory drug (NSAID) use or radiotherapy (RT). NSAIDs are associated with multiple toxicities, including gastrointestinal bleeding. Although RT has been shown to be more efficacious than NSAIDs at preventing HO, its cost-effectiveness has been questioned. Methods and Materials: We performed an analysis of the cost of postoperative RT to the hip compared with NSAID administration, taking into account the costs of surgery for HO formation, treatment-induced morbidity, and productivity loss from missed work. The costs of RT, surgical revision, and treatment of gastrointestinal bleeding were estimated using the 2007 Medicare Fee Schedule and inpatient diagnosis-related group codes. The cost of lost wages was estimated using the 2006 median salary data from the U.S. Census Bureau. Results: The cost of administering RT was estimated at $899 vs. $20 for NSAID use. After accounting for the additional costs associated with revision total hip arthroplasty and gastrointestinal bleeding, the corresponding estimated costs were $1,208 vs. $930. Conclusion: If the costs associated with treatment failure and treatment-induced morbidity are considered, the cost of NSAIDs approaches that of RT. Other NSAID morbidities and quality-of-life differences that are difficult to quantify add to the cost of NSAIDs. These considerations have led us to recommend RT as the preferred modality for use in prophylaxis against HO after total hip arthroplasty, even when the cost is considered

  4. Protective effect of Asparagus racemosus root extract against lethal total - body electron beam radiation induced damage in Swiss albino mice

    International Nuclear Information System (INIS)

    Sharmila, K.P.; Bhandary, B. Satheesh Kumar; Suchetha Kumari, N.; Bhat, Vadish S.; Shetty, Jayaram; Peter, Alex John; Jose, Jerish M.; Fernandes, Ronald

    2016-01-01

    To investigate the protective effect of Asparagus Racemosus Root ethanolic extract (ARE) in Swiss albino mice against acute lethal total - body Electron beam irradiation. Swiss Albino mice were used for the assessment of radiation induced sickness and 30 day survival analysis. Survival studies were determined using the Kaplan-Meier survival curves. The maximum survival was observed in the experimental mice pretreated with 200 mg/kg.b.wt. of ARE which also reduced the radiation sickness characteristics. This dose was considered as an optimal dose for radioprotection. Treatment of mice with ARE before irradiation delayed the onset of mortality as compared with the untreated irradiated controls. Present findings demonstrate the potential of ARE in mitigating radiation-induced mortality, which may be attributed to its free radical scavenging and increased antioxidant potential

  5. Parameter selection in limited data cone-beam CT reconstruction using edge-preserving total variation algorithms

    Science.gov (United States)

    Lohvithee, Manasavee; Biguri, Ander; Soleimani, Manuchehr

    2017-12-01

    There are a number of powerful total variation (TV) regularization methods that have great promise in limited data cone-beam CT reconstruction with an enhancement of image quality. These promising TV methods require careful selection of the image reconstruction parameters, for which there are no well-established criteria. This paper presents a comprehensive evaluation of parameter selection in a number of major TV-based reconstruction algorithms. An appropriate way of selecting the values for each individual parameter has been suggested. Finally, a new adaptive-weighted projection-controlled steepest descent (AwPCSD) algorithm is presented, which implements the edge-preserving function for CBCT reconstruction with limited data. The proposed algorithm shows significant robustness compared to three other existing algorithms: ASD-POCS, AwASD-POCS and PCSD. The proposed AwPCSD algorithm is able to preserve the edges of the reconstructed images better with fewer sensitive parameters to tune.

  6. Methods of the physical medicine therapy in prevention of heterotopic ossification after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Kojović Zoran

    2006-01-01

    Full Text Available Background/aim: In the prevention of periarticular heterotopic ossification (HO, a common complication after total hip arthroplasty (THA, nonsteroidal antiinflammatory drugs (NSAID and irradiation are used. Some theories presume that local hypoxia of the soft tissue causes HO. The aim of this study was to investigate if the early use of pulsed electromagnetic fields (PEMF could prevent this ossification since it accelerates the circulation and oxigenation of soft tissue. Methods. The study included three groups of the patients with primary THA. The group C consisted of 66 patients/79 hips who had only kinesitherapy in postoperative rehabilitation. The group B consisted of 117 patients/ 131 hips who had PEMF and interferential current (IC which, on average, started on the 14th day after the surgery combined with the standard kinesitherapy. The group A consisted of 117 patients/131 hips who had PEMF from the third postoperative day and IC from, on average, the 14th postoperative day with the standard kinesitherapy. The classification of HO was done on a standard AP roentgenograms of the hips, taken at least one year after the surgery. Results. The overall HO was seen in 50.63% of the group C patients, in 43.51% of the B group and in 16.67% of the group A. Severe HO (III and IV class according to Brooker was seen in 26.58% of the group C patients and in 6.10% of the group B, but none in the group A. Conclusion. According to the obtained results an early treatment with PEMF could prevent severe HO and reduce the overall HO.

  7. Failure of fragmented parathyroid gland autotransplantation to prevent permanent hypoparathyroidism after total thyroidectomy.

    Science.gov (United States)

    Lorente-Poch, Leyre; Sancho, Juan; Muñoz, Jose Luis; Gallego-Otaegui, Lander; Martínez-Ruiz, Carlos; Sitges-Serra, Antonio

    2017-03-01

    Parathyroid autotransplantation during total thyroidectomy leads to higher rates of postoperative hypocalcaemia. It has been argued, however, that it prevents permanent hypoparathyroidism. The impact of autografted normal parathyroid gland fragments on long-term parathyroid status has not been assessed properly. To clarify this, the short- and long-term parathyroid function was assessed in patients with three glands remaining in situ after total thyroidectomy, in whom the fourth gland was either autotransplanted (Tx) or accidentally resected (AR). Consecutive patients (n = 669) undergoing first-time total thyroidectomy were prospectively studied recording the number of parathyroid glands remaining in situ: PGRIS =4-(glands autografted + glands in the specimen). The study was focused on the subgroup of 186 patients with three parathyroid glands remaining in situ as a result of either accidental resection (AR, n = 76) or autotransplantation into the sternocleidomastoid muscle (Tx, n = 110). Prevalence of postoperative hypocalcaemia, protracted, and permanent hypoparathyroidism were compared between the two groups. Demographic, disease-related, laboratory, and surgical variables were recorded. All patients were followed for at least 1 year. Both groups were comparable in terms of disease and extent of surgery. Mean postoperative serum calcium was the same (AR: 1.97 ± 0.2 vs Tx: 1.97 ± 0.22 mmol/L). Rates of protracted (AR: 24% vs Tx: 25.5%) and permanent hypoparathyroidism (AR: 5.3% vs Tx: 7.3%) were similar in both groups. The prevalence of parathyroid failure syndromes after total thyroidectomy was similar whether a parathyroid gland was inadvertently excised or autotransplanted. Autotransplantation did not influence the permanent hypoparathyroidism rate.

  8. [Progress on prevention for anterior knee pain after primary total knee arthroplasty].

    Science.gov (United States)

    Gao, Yao-Zu; Chen, Chong-Wei; Wei, Xiao-Chun

    2014-04-01

    Total knee arthroplasty (TKA) identified as an effective treatment for ultimate knee joint disease can effectively relieve pain, correct deformity, improve knee function and enhance the quality of life of patients. Patient satisfaction has been increasingly considered as an important factor in evaluating the success of primary TKA. Anterior knee pain that usually appears in the region of the anterior knee is a recognized complaint for primary TKA and has a strong impact on the improvement of knee function and patient satisfaction of primary TKA. Accordingly, the relief of anterior knee pain has become one of the primary goals of primary TKA. At present, soft tissue lesions around the patellar caused by patellar maltracking and the elevation of internal pressure in subchondral bone because of the high contact stress of patellofemoral joint are both considered as the mechanism of anterior knee pain. For the past few years,on increasing number of studies have focused on the prevention of anterior knee pain following primary TKA. However, none of the past treatment such as patellar resurfacing, patellar denervation without patellar resurfacing or a mobile-bearing prosthesis has a good and affirmative effect on it. The prevention and treatment of anterior knee pain following primary TKA still is a difficult solved problem. To address this problem, we need further researches about the cause of anterior knee pain, knee joint prosthesis and biomechanics of patellofemoral joint, as well as lots of randomized controlled trials.

  9. Successful treatment of skin infiltration in childhood hematological malignancies with total skin electron beam therapy. A report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Ohkawa, Masahito; Shikano, Takaaki; Ueno, Norihiro; Tsujii, Hirohiko; Tono-oka, Tatsuhito; Matsumoto, Takahide.

    1988-07-01

    Two children with cutaneous lymphoma and leukemia who were treated with total skin electron beam therapy (TSEB) are described here. Patient 1. A 7-year-old boy was admitted because of a mass over the bilateral parotis and anemia. The white blood cell count on admission was 5,000/ul. Bone marrow examination revealed 70 per cent monoblasts (M5a type by FAB classification). Complete remission was obtained following the regimen of daunomycin, cytosine arabinoside, 6-mercaptopurine and prednisolone. He was again admitted because of a skin nodule on the left thigh 19 months after initial diagnosis. A biopsy of the skin nodule demonstrated monoblastic infiltration. He received 20 Grays (Gy) to the left thigh and this led to resolution of the skin nodule. At that time, other skin nodules appeared on the right upper and lower extremities. He was treated with TSEB. Daily doses of 1 Gy were given twice a week with a 4 MeV electron beam and a total dose of 10 Gy was administered over a period of 4 weeks. Although he again had a isolated skin relapse on the right shoulder, he remained in remission for 6 years after completing TSEB. Patient 2. A 6-year-old boy was admitted because of multiple skin lesions. Physical examination revealed 22 discrete, indurated skin nodules. a biopsy of a skin nodule demonstrated lymphoblast infiltration, confirming the diagnosis of B cell cutaneous lymphoma (stage IV). He was treated with CHOP (consisting of cyclophosphamide, adriamycin, vincristine and prednisolone). After two courses of CHOP therapy, he was treated with TSEB using the same technique described above. To date, the patient remains in remission 5 years after initial diagnosis.

  10. Effect of Diffuse Luminance Flicker Light Stimulation on Total Retinal Blood Flow Assessed With Dual-Beam Bidirectional Doppler OCT.

    Science.gov (United States)

    Aschinger, Gerold C; Schmetterer, Leopold; Fondi, Klemens; Aranha Dos Santos, Valentin; Seidel, Gerald; Garhöfer, Gerhard; Werkmeister, René M

    2017-02-01

    We assess the increase in total retinal blood flow (TRBF) induced by flicker stimulation of the human retina in vivo and investigate the flicker induced hyperemia by means of a vascular flow model of the retinal circulation to study neurovascular coupling (NC). In six healthy subjects, TRBF was measured before and during stimulation with diffuse luminance flicker. Blood flow velocities in retinal vessels were measured via dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT), retinal vessel diameters were assessed based on FD-OCT phase data. This allowed for the calculation of TRBF before and during visual stimulation. Additionally, a mathematical flow model for the retinal vasculature was adapted to study the implications of diameter variations on retinal perfusion. Measured and simulated perfusion was compared to draw conclusions on the diameter variations in different layers of the vascular tree. The measured mean baseline flow was 36.4 ± 6.5 μl/min while the mean flow during flicker stimulation was 53.4% ± 8.3 μl/min. The individual increase in TRBF during flicker stimulation ranged between 34% and 66%. The average increase in TRBF over all measured subjects was 47.6% ± 12.6%. Dual-beam bidirectional Doppler FD-OCT allowed quantifying NC in the human retina in vivo and may be a promising method for monitoring alterations in NC caused by various pathologies. The comparison of the measured data with the results obtained in the simulated vasculature indicates that the vasodilation induced by NC is more pronounced in smaller vessels.

  11. Total glucosides of paeony prevents juxta-articular bone loss in experimental arthritis.

    Science.gov (United States)

    Wei, Chen Chao; You, Fan Tian; Mei, Li Yu; Jian, Sun; Qiang, Chen Yong

    2013-07-21

    Total glucosides of paeony (TGP) is a biologically active compound extracted from Paeony root. TGP has been used in rheumatoid arthritis therapy for many years. However, the mechanism by which TGP prevents bone loss has been less explored. TGP was orally administered for 3 months to New Zealand rabbits with antigen-induced arthritis (AIA). Digital x-ray knee images and bone mineral density (BMD) measurements of the subchondral knee bone were performed before sacrifice. Chondrocytes were observed using transmission electron microscopy (TEM). Histological analysis and mRNA expression of receptor activator of nuclear factor-B ligand (RANKL) and osteoprotegerin (OPG) were evaluated in joint tissues. The BMD value in TGP rabbits was significantly higher compared with that seen in the AIA model rabbits. In addition, the subchondral bone plate was almost completely preserved by TGP treatment, while there was a decrease in bone plate integrity in AIA rabbits. There was less damage to the chondrocytes of the TGP treated group. Immunohistochemical examination of the TGP group showed that a higher percentage of TGP treated chondrocytes expressed OPG as compared to the chondrocytes isolated from AIA treated animals. In contrast, RANKL expression was significantly decreased in the TGP treated group compared to the AIA group. In support of the immunohistochemistry data, the expression of RANKL mRNA was decreased and OPG mRNA expression was enhanced in the TGP group when compared to that of the AIA model group. These results reveal that TGP suppresses juxta-articular osteoporosis and prevents subchondral bone loss. The decreased RANKL and increased OPG expression seen in TGP treated animals could explain how administration of TGP maintains higher BMD.

  12. Surgical site infection after total en bloc spondylectomy: risk factors and the preventive new technology.

    Science.gov (United States)

    Hayashi, Hiroyuki; Murakami, Hideki; Demura, Satoru; Kato, Satoshi; Yoshioka, Katsuhito; Shinmura, Kazuya; Yokogawa, Noriaki; Ishii, Takayoshi; Fang, Xiang; Shirai, Toshiharu; Tsuchiya, Hiroyuki

    2015-01-01

    Surgical site infection (SSI) associated with instruments remains a serious and common complication in patients who undergo total en bloc spondylectomy (TES). It is very important that the risk factors for SSI are known to prevent it. The purpose of the study was to identify independent risk factors for SSI after TES and evaluate the positive effect of iodine-supported spinal instruments in the prevention of SSI after TES. This is a retrospective clinical study. One hundred twenty-five patients who underwent TES for vertebral tumor were evaluated. Incidence rate of SSI, risk factors for SSI after TES, and safety of iodine-supported spinal instruments were the outcome measures. Risk factors for SSI were analyzed using logistic regression. In recent 69 patients with iodine-supported spinal instruments, the thyroid hormone levels in the blood were examined to confirm if iodine from the implant influenced thyroid function. Postoperative radiological evaluations were performed regularly. The rate of SSI was 6.4% (8/125 patients). By multivariate logistic regression, combined anterior and posterior approach and nonuse of iodine-supported spinal instruments were associated with an increased risk of SSI. The rate of SSI without iodine-supported spinal instruments was 12.5%, whereas the rate with iodine-supported spinal instruments was 1.4%. This difference was statistically significant. There were no detected abnormalities of thyroid gland function with the use of iodine-supported instruments. Among the 69 patients with iodine-supported spinal instruments, 2 patients required additional surgery because of instrument failure. However, there were no obvious involvements with the use of iodine-supported spinal instruments. This study identified combined anterior and posterior approach and nonuse of iodine-supported spinal instruments to be independent risk factors for SSI after TES. Iodine-supported spinal instrument was extremely effective for prevention of SSI in patients

  13. Preventing vacuum leaks in the Continuous Electron Beam Accelerator Facility cavity pair bellows

    International Nuclear Information System (INIS)

    Henkel, D.P.; Doolittle, L.R.

    1994-01-01

    Occasional vacuum leaks have occurred in bellows assemblies of helium pressure vessels at the Continuous Electron Beam Accelerator Facility. The flanged stainless steel bellows assemblies are used to connect the niobium rf cavity pairs to the surrounding liquid helium pressure vessels. An investigation of the source of these leaks has revealed a through-thickness network of microcracks in the cuff weld zones. The cuff material contained a mixture of soft and very hard elongated intermetallic inclusions that were oriented parallel with the weld fusion line; these inclusions served as crack initiation sites. Surface-exposed inclusions, in contact with a chlorine residue from a postweld machining process, induced crevice corrosion during a year of storage. Residual stresses in the weld led to a combination of lamellar tearing and stress corrosion cracking. Propagation of the cracks from one inclusion to another resulted in continuous vacuum leakage paths from the primary (2 K) helium circuit to the vacuum insulation space. Additional vacuum leaks were prevented by reconfiguring the weld geometry and avoiding any processing with chlorinated substances

  14. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4 + T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. [Prevention of prothesis dislocation after the revision of total hip arthroplasty].

    Science.gov (United States)

    Li, Yong-jiang; Zhang, Li-cheng; Yang, Guo-jing; Zhang, Chun-cai; Wang, Wei-liang; Lin, Rui-xin; Cai, Chun-yuan

    2008-03-01

    To explore the role of reconstruction of the posterior capsule and external rotators in prevention of postoperative dislocation in total hip arthroplasty revision following the posterolateral approach. Forty-five patients (47 hips) with the mean age of 65 years (55 to 78 years)of failed total hip arthroplasty were revised following the posterolateral approach. Posterior capsule was sutured to the anterosuperior portion of the capsule from where it had been detached, and the external rotators were then reattached to the soft tissue at the tip of the greater trochanter using 1.0 silk suture in surgery. The dislocation rate and risk factors were reviewed retrospectively to determine if closing the posterior capsule resulted in fewer dislocations. The femoral prosthesis and acetabular prosthesis were revised in 29 patients (31 hips), the liner was exchanged in 5 patients (5 hips), and the acetabular prosthesis or femoral components were revised in 10 patients (10 hips) and one patient (one hip) respectively. The procedure was the patient's first revision in 29 patients (30 hips), the second revision in 15 patients (16 hips), and the third revision in one patient(one hip). Radiographic evaluation included lower limb discrepancy, acetabular phase, femoral offset, anteversion angle, prosthetic loosening before and after revision. Function evaluation based on Harris score system. All patients were followed up with an average of 2.7 years. None of the patients sustained dislocation or infection, except one patient felt the anterior instability but without dislocation, X-ray revealed the acetabular component was in excessively anteversion. Lower leg discrepancy, acetabular abduction, anteversion femoral offest and collodiaphyseal angle were restored to normal level after operation on the basis of X-ray. One of the acetabular components and one of the femoral components were loose without dislocation. The Harris hip score improved from (49.13 +/- 15.53) points preoperatively

  16. Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation

    Science.gov (United States)

    Han, Hao; Gao, Hao; Xing, Lei

    2017-08-01

    Excessive radiation exposure is still a major concern in 4D cone-beam computed tomography (4D-CBCT) due to its prolonged scanning duration. Radiation dose can be effectively reduced by either under-sampling the x-ray projections or reducing the x-ray flux. However, 4D-CBCT reconstruction under such low-dose protocols is prone to image artifacts and noise. In this work, we propose a novel joint regularization-based iterative reconstruction method for low-dose 4D-CBCT. To tackle the under-sampling problem, we employ spatiotemporal tensor framelet (STF) regularization to take advantage of the spatiotemporal coherence of the patient anatomy in 4D images. To simultaneously suppress the image noise caused by photon starvation, we also incorporate spatiotemporal nonlocal total variation (SNTV) regularization to make use of the nonlocal self-recursiveness of anatomical structures in the spatial and temporal domains. Under the joint STF-SNTV regularization, the proposed iterative reconstruction approach is evaluated first using two digital phantoms and then using physical experiment data in the low-dose context of both under-sampled and noisy projections. Compared with existing approaches via either STF or SNTV regularization alone, the presented hybrid approach achieves improved image quality, and is particularly effective for the reconstruction of low-dose 4D-CBCT data that are not only sparse but noisy.

  17. Use of an Electron Beam Melting Manufactured Titanium Collared Cementless Femoral Stem to Resist Subsidence After Canine Total Hip Replacement.

    Science.gov (United States)

    Liska, William D; Doyle, Nancy D

    2015-10-01

    To evaluate the effect of a collared electron beam melting (EBM)-manufactured titanium cementless femoral stem on implant subsidence after total hip replacement (THR). Prospective study Dogs (n = 26); 33 THR. Records were maintained on the first 110 consecutive THR using an EBM collared femoral stem. Radiographs on the first 33 THR that had 6-months follow-up were evaluated for implant subsidence. These results were compared to 27 dogs with subsidence after THR with a Co Cr collarless stem. Dogs that had EBM collared stem THR had a mean body weight of 35.4 kg, body condition score (BCS) of 6.21, and mean canal flare index (CFI) of 1.56. EBM stem sizes used (number implanted) were #7 (13), #8 (10), #9 (8), and #10 (2). Subsidence of collared stems did not occur if the collar was in contact with cortical bone during surgery. Subsidence of 1-3 mm occurred closing a gap between the collar and bone if contact was not made during surgery, but subsidence stopped once contact was made. No major complications directly related to the EBM collared stem were encountered. A collar on a cementless femoral stem in contact with cortical bone resists subsidence. © Copyright 2015 by The American College of Veterinary Surgeons.

  18. Fine Particulate Matter and Total Mortality in Cancer Prevention Study Cohort Reanalysis

    Directory of Open Access Journals (Sweden)

    James E. Enstrom

    2017-03-01

    Full Text Available Background: In 1997 the US Environmental Protection Agency (EPA established the National Ambient Air Quality Standard (NAAQS for fine particulate matter (PM2.5, largely because of its positive relationship to total mortality in the 1982 American Cancer Society Cancer Prevention Study (CPS II cohort. Subsequently, EPA has used this relationship as the primary justification for many costly regulations, most recently the Clean Power Plan. An independent analysis of the CPS II data was conducted in order to test the validity of this relationship. Methods: The original CPS II questionnaire data, including 1982 to 1988 mortality follow-up, were analyzed using Cox proportional hazards regression. Results were obtained for 292 277 participants in 85 counties with 1979-1983 EPA Inhalable Particulate Network PM2.5 measurements, as well as for 212 370 participants in the 50 counties used in the original 1995 analysis. Results: The 1982 to 1988 relative risk (RR of death from all causes and 95% confidence interval adjusted for age, sex, race, education, and smoking status was 1.023 (0.997-1.049 for a 10 µg/m3 increase in PM2.5 in 85 counties and 1.025 (0.990-1.061 in the 50 original counties. The fully adjusted RR was null in the western and eastern portions of the United States, including in areas with somewhat higher PM2.5 levels, particularly 5 Ohio Valley states and California. Conclusion: No significant relationship between PM2.5 and total mortality in the CPS II cohort was found when the best available PM2.5 data were used. The original 1995 analysis found a positive relationship by selective use of CPS II and PM2.5 data. This independent analysis of underlying data raises serious doubts about the CPS II epidemiologic evidence supporting the PM2.5 NAAQS. These findings provide strong justification for further independent analysis of the CPS II data.

  19. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  20. GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation

    International Nuclear Information System (INIS)

    Jia Xun; Lou Yifei; Li Ruijiang; Song, William Y.; Jiang, Steve B.

    2010-01-01

    Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who are essentially excluded from receiving IGRT for this reason. The goal of this work is to develop a fast GPU-based algorithm to reconstruct CBCT from undersampled and noisy projection data so as to lower the imaging dose. Methods: The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. The authors developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multigrid technique is also employed. Results: It is found that 20-40 x-ray projections are sufficient to reconstruct images with satisfactory quality for IGRT. The reconstruction time ranges from 77 to 130 s on an NVIDIA Tesla C1060 (NVIDIA, Santa Clara, CA) GPU card, depending on the number of projections used, which is estimated about 100 times faster than similar iterative reconstruction approaches. Moreover, phantom studies indicate that the algorithm enables the CBCT to be reconstructed under a scanning protocol with as low as 0.1 mA s/projection. Comparing with currently widely used full-fan head and neck scanning protocol of ∼360 projections with 0.4 mA s/projection, it is estimated that an overall 36-72 times dose reduction has been achieved in our fast CBCT reconstruction algorithm. Conclusions: This work indicates that the developed GPU-based CBCT reconstruction algorithm is capable of lowering imaging dose considerably. The high computation efficiency in this algorithm makes the iterative CBCT reconstruction approach applicable in real clinical environments.

  1. Prevention of strong stench for stocked radioisotope sewerage using total water treatment agent for small-sized cooling towers

    International Nuclear Information System (INIS)

    Aoki, Katsumi; Nishimaki, Toshiyuki; Furuse, Yuko; Shinozuka, Akiko

    1996-01-01

    In general, the sewerage at radioisotope laboratories has very strong stench. We treated the sewerage with a total water treatment agent (Tachileslegi, Nippon Nouyaku Co., Ltd. ) that is widely used for prevention of slime, scale, corrosion in cooling towers. As the result, the stench was decreased to about two thirds to that of control estimated by odor-test. (author)

  2. MO-AB-BRA-08: Rapid Treatment Field Uniformity Optimization for Total Skin Electron Beam Therapy Using Cherenkov Imaging

    International Nuclear Information System (INIS)

    Andreozzi, J; Zhang, R; Glaser, A; Pogue, B; Jarvis, L; Williams, B; Gladstone, D

    2015-01-01

    Purpose: To evaluate treatment field heterogeneity resulting from gantry angle choice in total skin electron beam therapy (TSEBT) following a modified Stanford dual-field technique, and determine a relationship between source to surface distance (SSD) and optimized gantry angle spread. Methods: Cherenkov imaging was used to image 62 treatment fields on a sheet of 1.2m x 2.2m x 1.2cm polyethylene following standard TSEBT setup at our institution (6 MeV, 888 MU/min, no spoiler, SSD=441cm), where gantry angles spanned from 239.5° to 300.5° at 1° increments. Average Cherenkov intensity and coefficient of variation in the region of interest were compared for the set of composite Cherenkov images created by summing all unique combinations of angle pairs to simulate dual-field treatment. The angle pair which produced the lowest coefficient of variation was further studied using an ionization chamber. The experiment was repeated at SSD=300cm, and SSD=370.5cm. Cherenkov imaging was also implemented during TSEBT of three patients. Results: The most uniform treatment region from a symmetric angle spread was achieved using gantry angles +/−17.5° about the horizontal axis at SSD=441cm, +/−18.5° at SSD=370.5cm, and +/−19.5° at SSD=300cm. Ionization chamber measurements comparing the original treatment spread (+/−14.5°) and the optimized angle pair (+/−17.5°) at SSD=441cm showed no significant deviation (r=0.999) in percent depth dose curves, and chamber measurements from nine locations within the field showed an improvement in dose uniformity from 24.41% to 9.75%. Ionization chamber measurements correlated strongly (r=0.981) with Cherenkov intensity measured concurrently on the flat Plastic Water phantom. Patient images and TLD results also showed modest uniformity improvements. Conclusion: A decreasing linear relationship between optimal angle spread and SSD was observed. Cherenkov imaging offers a new method of rapidly analyzing and optimizing TSEBT setup

  3. Fluence measurements applied to 5-20 MeV/amu ion beam dosimetry by simultaneous use of a total-absorption calorimeter and a Faraday cup

    CERN Document Server

    Kojima, T; Takizawa, H; Tachibana, H; Tanaka, R

    1998-01-01

    A Faraday cup was fabricated for measuring the beam current of a few tens MeV/amu ion beams of the TIARA AVF cyclotron. It has been applied as a beam monitor for studying the characteristics of film dosimeters that are well-established for high doses of sup 6 sup 0 Co gamma-rays and 1 to 10 MeV electrons. A total absorption calorimeter designed to measure energy fluence has also been tested for estimating the uncertainty in fluence measurement of 5-20 MeV/amu ion beams, by simultaneous use of the calorimeter and the Faraday cup in a broad uniform fluence field. The estimated fluence was evaluated on the basis of nominal particle energy values derived from the cyclotron acceleration parameters. The average ratio of the measured fluence values to the estimated values is 1.024, and the average precision is within +-2% at a 68% confidence level, for most of the ion beams with a range of kinetic energy per nucleon, 5-20 MeV/amu, at an integrated charge above 5 nC/cm sup 2.

  4. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  5. Prevention of venous thromboembolic disease after total hip and knee arthroplasty.

    Science.gov (United States)

    Lieberman, Jay R; Hsu, Wellington K

    2005-09-01

    Patients undergoing total hip and knee arthroplasty are at increased risk for the development of venous thromboembolic disease, and there is general agreement that these patients require prophylaxis. The selection of a prophylactic agent involves a balance between efficacy and safety and often needs to be individualized for specific patients and institutions. Despite extensive research, the ideal agent for prophylaxis against deep venous thrombosis has not been identified. The results of randomized trials indicate that low-molecular-weight heparin, warfarin, and fondaparinux are the most effective prophylactic agents after total hip arthroplasty and that low-molecular-weight heparin, warfarin, fondaparinux, and pneumatic compression boots are the most effective agents after total knee arthroplasty. The duration of prophylaxis against deep venous thrombosis after total hip and knee arthroplasty remains controversial. Prophylaxis should be continued beyond hospital discharge. In the future, the determination of the duration of prophylaxis will be based on the risk stratification of individual patients. The practice of discharging patients from the hospital without prophylaxis, even when the decision is based on negative results of procedures that screen for the presence of deep venous thrombosis, is not cost-effective.

  6. Evaluation of apoptosis and micronucleation induced by reactor neutron beams with two different cadmium ratios in total and quiescent cell populations within solid tumors

    International Nuclear Information System (INIS)

    Masunaga, Shin-ichiro; Ono, Koji; Sakurai, Yoshinori; Takagaki, Masao; Kobayashi, Tooru; Kinashi, Yuko; Suzuki, Minoru

    2001-01-01

    Purpose: Response of quiescent (Q) and total tumor cells in solid tumors to reactor neutron beam irradiation with two different cadmium (Cd) ratios was examined in terms of micronucleus (MN) frequency and apoptosis frequency, using four different tumor cell lines. Methods and Materials: C57BL mice bearing EL4 tumors, C3H/He mice bearing SCC VII or FM3A tumors, and Balb/c mice bearing EMT6/KU tumors received 5-bromo-2'-deoxyuridine (BrdU) continuously for 5 days via implanted mini-osmotic pumps to label all proliferating (P) cells. Thirty min after i.p. injection of sodium borocaptate- 10 B (BSH), or 3 h after oral administration of p-boronophenylalanine- 10 B (BPA), the tumors were irradiated with neutron beams. The tumors without 10 B-compound administration were irradiated with neutron beams or γ-rays. This neutron beam irradiation was performed using neutrons with two different Cd ratios. The tumors were then excised, minced, and trypsinized. The tumor cell suspensions thus obtained were incubated with cytochalasin-B (a cytokinesis blocker), and the MN frequency in cells without BrdU labeling (=Q cells) was determined using immunofluorescence staining for BrdU. Meanwhile, for apoptosis assay, 6 h after irradiation, tumor cell suspensions obtained in the same manner were fixed, and the apoptosis frequency in Q cells was also determined with immunofluorescence staining for BrdU. The MN and apoptosis frequencies in total (P+Q) tumor cells were determined from the tumors that were not pretreated with BrdU. Results: Without 10 B-compounds, the sensitivity difference between total and Q cells was reduced by neutron beam irradiation. Under our particular neutron beam irradiation condition, relative biological effectiveness (RBE) of neutrons was larger in Q cells than in total cells, and the RBE values were larger for low Cd-ratio than high Cd-ratio neutrons. With 10 B-compounds, both frequencies were increased for each cell population, especially for total cells. BPA

  7. Glutamate prevents intestinal atrophy via luminal nutrient sensing in a mouse model of total parenteral nutrition

    DEFF Research Database (Denmark)

    Xiao, Weidong; Feng, Yongjia; Holst, Jens Juul

    2014-01-01

    Small intestine luminal nutrient sensing may be crucial for modulating physiological functions. However, its mechanism of action is incompletely understood. We used a model of enteral nutrient deprivation, or total parenteral nutrition (TPN), resulting in intestinal mucosal atrophy and decreased...... was regulated by T1R3 and mGluR5, suggesting a novel negative regulator pathway for IEC proliferation not previously described. Loss of luminal nutrients with TPN administration may widely affect intestinal taste sensing. GLM has previously unrecognized actions on IEC growth and EBF. Restoring luminal sensing...

  8. The suggestion of droplets generation prevention method of CNx coating by ion beam assisted deposition

    International Nuclear Information System (INIS)

    Yagi, Yuji; Tokoroyama, Takayuki; Kousaka, Hiroyuki; Umehara, Noritsugu; Fuwa, Yoshio; Manabe, Kazuyoshi

    2013-01-01

    It has been reported that the carbon nitride (CNx) coating was the super-low friction in which friction coefficient was less than 0.01, and it attracts attention as a high wear resistance and low friction material. When synthesizing a CNx coating with Ion Beam Assisted Deposition (IBAD) method, it was clear that the small asperities called droplets was generated onto the CNx coating surface with increasing thickness, and these droplets generated high friction. Therefore, it is necessary to clarify droplets generation mechanism to reduce droplets. To establish optimal coating conditions for controlling droplets were clarified by paying attention to the energy of an electron beam and the shape of a carbon target. First of all, 300 nm thickness CNx coatings were synthesized with five different filament current densities to clarify the relationship between the filament current density and droplet heights. Secondly, the effect of carbon target shape on droplets generation was confirmed with normal and processed carbon target. Finally, friction coefficient of these surfaces was measured by friction tests under PAO lubrication. (author)

  9. [Study on total glucosides of peony preventing non-obese diabetic mice from sialoadenitis].

    Science.gov (United States)

    Li, Chun-Lei; He, Jing; Hua, Hong

    2011-04-01

    To investigate the immunosuppressive effect of total glucosides of peony (TGP) on sialoadenitis in non-obese diabetic mice (NOD mice) and explore its possible mechanism. 27 female five-week-old NOD mice were randomly divided into three groups: TGP, hydroxychloroquine (HCQ) and normal saline (NS) group. One week later, they were administered intragastrically in TGP, HCQ and NS respectively. Three mice from each group were sacrificed at the age of 10, 15 and 20 weeks. The saliva flow, serum and submandibular glands were collected at these time points. Histological changes of submandibular glands were examined by HE staining. The expression of autoantibodies (SSA, SSB and anti-alpha-fodrin) and associated cytokines in serum were detected by enzyme-linked immunosorbent assay (ELISA). Compared with the NS group, salivary flow was significantly increased, the extent of the histological changes were ameliorated, the autoantibodies in serum were significantly decreased and the imbalance of Th1/Th2 cytokines was remedied in the mice treated with TGP and HCQ. There were no significant differences between the two groups treated with TGP and HCQ (P > 0.05). TGP can effectively ameliorate sialoadenitis on NOD mice. The mechanism was thought to be associated with the protection of submandibular gland from intense inflammation and the correction of Th1/Th2 cytokines imbalance.

  10. Prevention of deep vein thrombosis after total knee arthroplasty. Coumadin versus pneumatic calf compression.

    Science.gov (United States)

    Hodge, W A

    1991-10-01

    The rate of deep vein thrombosis (DVT) after total knee arthroplasty (TKA) without prophylaxis has been reported as high as 84%. Coumadin anticoagulation and pneumatic calf compression (PCC) boots are two current therapies that have been thought to be effective in reducing this high rate of DVT. To investigate these two methods, a nonrandomized prospective study was designed. The first group involved treating 48 consecutive knee arthroplasties with a regimen of coumadin anticoagulation. The second group involved 81 consecutive knee arthroplasties treated with sequential PCC boots. Bilateral lower extremity venography was performed between the eighth and tenth hospital postoperative days. The overall incidence of DVT in the coumadin group was 33%, with 29% having calf thrombi and 6% having thigh thrombi. The overall incidence of DVT in the boot group was 31%, with 27% having calf thrombi and 6% having thigh thrombi. In both groups, there were no treatment-related complications. Cost analysis of the administration of each type of therapy showed coumadin to be approximately 50% more expensive than PCC boots. Although coumadin and PCC boot therapy are safe and effective in reducing the incidence of DVT after TKA, there are economic factors that make the latter a more favorable option.

  11. Total skin electron beam and non-myeloablative allogeneic hematopoietic stem-cell transplantation in advanced mycosis fungoides and Sezary syndrome.

    Science.gov (United States)

    Duvic, Madeleine; Donato, Michele; Dabaja, Bouthaina; Richmond, Heather; Singh, Lotika; Wei, Wei; Acholonu, Sandra; Khouri, Issa; Champlin, Richard; Hosing, Chitra

    2010-05-10

    Transformed mycosis fungoides (MF) and Sézary syndrome (SS) are currently incurable. We studied the safety and efficacy of total skin electron beam with allogeneic hematopoietic stem-cell transplantation (HSCT) in patients with cutaneous T-cell lymphoma (CTCL). Nineteen patients with advanced CTCL (median age, 50 years; four prior therapies) underwent total skin electron beam radiation followed by allogeneic HSCT between July 2001 and July 2008. Sixteen patients were conditioned with fludarabine (125 mg/m(2)) and melphalan (140 mg/m(2)) plus thymoglobulin (for mismatched donors). Graft-versus-host disease (GVHD) prophylaxis was with tacrolimus/mini methotrexate. Eighteen patients experienced engraftment, and one died as a result of sepsis on day 16. Median time to recovery of absolute neutrophil count (ANC) was 12 days. Fifteen achieved full donor chimerism, 12 had acute GVHD, and 12 were treated for chronic GVHD. The overall intent-to-treat response was 68%, and the complete response rate was 58%. Four of six patients died in complete remission as a result of bacterial sepsis (n = 2), chronic GVHD and fungal infection (n = 1), or lung cancer (n = 1); only two died as a result of progressive disease. Eight experienced relapse in skin; five regained complete response with reduced immunosuppression or donor lymphocyte infusions. Eleven of 13 are currently in complete remissions, with median follow-up of 19 months (range, 1.3 to 8.3 years). Median overall survival has not been reached. Total skin electron beam followed by allogeneic stem-cell transplantation merits additional evaluation for a selected group of patients with refractory, advanced, cutaneous T-cell lymphoma with evidence for graft-versus-tumor effect.

  12. Total and partial cross sections of the $^{112}$Sn($\\alpha,\\gamma$)$^{116}$Te reaction measured via in-beam $\\gamma$-ray spectroscopy

    OpenAIRE

    Netterdon, L.; Mayer, J.; Scholz, P.; Zilges, A.

    2015-01-01

    An extended database of experimental data is needed to address uncertainties of the nuclear-physics input parameters for Hauser-Feshbach calculations. Especially $\\alpha$+nucleus optical model potentials at low energies are not well known. The in-beam technique with an array of high-purity germanium (HPGe) detectors was successfully applied to the measurement of absolute cross sections of an ($\\alpha$,$\\gamma$) reaction on a heavy nucleus at sub-Coulomb energies. The total and partial cross-s...

  13. Electron beam treatment technology for exhaust gas for preventing acid rain

    International Nuclear Information System (INIS)

    Aoki, Shinji

    1990-01-01

    Recently, accompanying the increase of the use of fossil fuel, the damage due to acid rain such as withering of trees and extinction of fishes and shells has occurred worldwide, and it has become a serious problem. The sulfur oxides and nitrogen oxides contained in exhaust gas are oxidized by the action of sunbeam to become sulfuric acid and nitric acid mists, which fall in the form of rain. Acid rain is closely related to the use of the coal containing high sulfur, and it hinders the use of coal which is rich energy source. In order to simplify the processing system for boiler exhaust gas and to reduce waste water and wastes, Ebara Corp. developed the dry simultaneous desulfurizing and denitrating technology utilizing electron beam in cooperation with Japan Atomic Energy Research Institute. The flow chart of the system applied to the exhaust gas treatment in a coal-fired thermal power station is shown. The mechanism of desulfurization and denitration, and the features of this system are described. The demonstration plant was constructed in a coal-fired thermal power station in Indianapolis, Indiana, USA, and the trial operation was completed in July, 1987. The test results are reported. (K.I.)

  14. Preoperative irradiation for prevention of heterotopic ossification following prosthetic total hip replacement. Results of a prospective study in 462 hips

    International Nuclear Information System (INIS)

    Koelbl, O.; Seufert, J.; Pohl, F.; Flentje, M.; Tauscher, A.; Springorum, H.W.; Lehmann, H.

    2003-01-01

    Background: The effectiveness of pre- or postoperative radiotherapy for prevention of heterotopic ossification (HO) following total hip replacement (THR) has already been demonstrated in the past. Thereby, in most studies using preoperative radiotherapy patients were irradiated 300 mg) within the first 7 postoperative days and previous ipsi- or contralateral HO influenced the incidence of HO in multivariate analysis. Conclusion: Preoperative radiotherapy on the evening before surgery is an effective treatment modality to reduce overall (Brooker 1-4) and clinically relevant, severe HOs (Brooker 3-4), and includes several advantages compared to postoperative irradiation. Previous ipsi- and contralateral HOs were identified as high risk factors for HO in this study. In patients with these risk factors, the incidence of HO increased. (orig.)

  15. Merged-beams energy-loss technique for electron-ion excitation: Absolute total cross sections for O5+(2s→2p)

    International Nuclear Information System (INIS)

    Bell, E.W.; Guo, X.Q.; Forand, J.L.; Rinn, K.; Swenson, D.R.; Thompson, J.S.; Dunn, G.H.; Bannister, M.E.; Gregory, D.C.; Phaneuf, R.A.; Smith, A.C.H.; Mueller, A.; Timmer, C.A.; Wahlin, E.K.; DePaola, B.D.; Belic, D.S.

    1994-01-01

    A merged-beams electron-energy-loss technique is described, by which absolute cross sections can be measured for near-threshold electron-impact excitation of multipy charged ions. Results are reported here for absolute total electron-impact excitation cross sections for the O 5+ (2s→2p) transition from below threshold to 1.6 eV above threshold. The experimental data are in good agremeent with a seven-state close-coupling calculation throughout the energy range of the experiment. Results agree with calculations showing that more than 90% of the electrons causing excitation are ejected in the backward direction in the center-of-mass frame. This backscattering is shown in both quantum-mechanical and semiclassical calculations. Evidence is observed for high-lying metastable autoionizing states with a lifetime of approximately 0.9 μs which are made to ionize by electron impact

  16. Effect of bisphosphonates in preventing femoral periprosthetic bone resorption after primary cementless total hip arthroplasty: a meta-analysis.

    Science.gov (United States)

    Zhao, Xinyu; Hu, Dongcai; Qin, Jun; Mohanan, Rahul; Chen, Liaobin

    2015-05-13

    Bone loss leading to aseptic loosening of the prosthesis and periprosthetic fracture is a mode of failure in cementless total hip arthroplasty (THA). The aim of this meta-analysis was to evaluate the effect of bisphosphonates in preventing femoral periprosthetic bone resorption following primary cementless THA zone by zone. Clinical randomized controlled trials concerning bisphosphonates application after primary cementless THA published up to October 2014 were retrieved from PubMed, Cochrane library, and Embase databases. The methodological quality of the included studies was assessed by the Physiotherapy Evidence Database (PEDro) scale. Data analysis was performed using StataSE12.0. Ten randomized controlled trials involving a total of 502 patients were assessed; the bisphosphonates group included 256 patients and the control group included 246 patients. The meta-analysis showed that the bone mineral density (BMD) of most femoral periprosthetic zones in bisphosphonates group was significantly higher than that in the control group at 3 months postoperatively except zone 5 with no significant difference. At 6 and 12 months, the BMD of bisphosphonates group was much higher than that in control group except zone 5, which showed no statistical difference. The BMD of bisphosphonates group was persistently higher than control group in zone 6 and 7 at 5 years postoperatively, while the other zones had no significant difference. Both serum bone alkaline phosphatase and urinary type I collagen N-telopeptide were significantly suppressed by bisphosphonates at 3, 6, and 12 months. Bisphosphonates seem to decrease early femoral periprosthetic bone resorption after primary cementless THA. Drug efficacy was found to be long-standing in the main load-bearing zones.

  17. Low-Dose Total Skin Electron Beam Therapy as a Debulking Agent for Cutaneous T-Cell Lymphoma: An open-label prospective phase II study

    DEFF Research Database (Denmark)

    Kamstrup, M R; Lindahl, Lise Maria; Gniadecki, R

    2012-01-01

    Background: Total skin electron beam therapy (TSEBT) is a powerful treatment for cutaneous T-cell lymphomas (CTCL). Based on the occurrence of relapses with low radiation doses, doses of 30-36 Gy are commonly used but most patients still eventually relapse and repeat treatment courses are limited...... due to the cumulative toxicity. Complete response rates are about 60-90% for T2-4 stages with a 5-year relapse-free survival of 10-25% for stages IB-III. Objectives: To evaluate prospectively the efficacy of low-dose TSEBT (10 Gy) in terms of complete cutaneous response rate, overall response rate...... and response duration in CTCL. Methods: Ten patients with stage IB-IV mycosis fungoides (MF) were treated in an open-label manner with 4 fractions of 1 Gy/week TSEB to a total skin dose of 10 Gy. Treatment responses were assessed at 1 and 3 months after treatment and subsequently at least every 6 months...

  18. Prevention

    Science.gov (United States)

    ... Error processing SSI file About Heart Disease & Stroke Prevention Heart disease and stroke are an epidemic in ... secondhand smoke. Barriers to Effective Heart Disease & Stroke Prevention Many people with key risk factors for heart ...

  19. Total Retinal Blood Flow in a Nonhuman Primate Optic Nerve Transection Model Using Dual-Beam Bidirectional Doppler FD-OCT and Microsphere Method.

    Science.gov (United States)

    Told, Reinhard; Wang, Lin; Cull, Grant; Thompson, Simon J; Burgoyne, Claude F; Aschinger, Gerold C; Schmetterer, Leopold; Werkmeister, René M

    2016-03-01

    We validated noninvasive Doppler-optical coherence tomography (OCT) blood flow measurements against the terminal microsphere method in a surgical induced optic nerve transection nonhuman primate model. In 6 nonhuman primates, total retinal blood flow (TRBF) was measured with a custom-built dual-beam bidirectional Doppler Fourier Domain (FD)-OCT. Peripapillary retinal nerve fiber layer thickness (RNFLT) was measured by Spectralis spectral-domain (SD)-OCT. Measurements were performed every 10 to 15 days before and after unilateral optic nerve transection (ONT) until RNFLT was reduced by more than 40% from baseline. Before the animals were killed, TRBF was measured using the microsphere technique. A significant correlation between all arterial and venous Doppler OCT TRBF measurements was found in ONT and contralateral control eyes (both P FD-OCT and the microsphere method. It also was possible to monitor changes over time in TRBF after ONT with Doppler OCT. These findings highlight the accuracy and potential of noninvasive Doppler OCT to provide valuable information for detecting early changes in ocular disease in future.

  20. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma: an open clinical study and pooled data analysis.

    Science.gov (United States)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena

    2015-05-01

    Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Gniadecki, Robert [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Iversen, Lars [Department of Dermatology, Aarhus University Hospital, Aarhus (Denmark); Skov, Lone [Department of Dermatology, Gentofte Hospital, University of Copenhagen, Copenhagen (Denmark); Petersen, Peter Meidahl [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Loft, Annika [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.

  2. Assessment of total vascular resistance and total body water in normotensive women during the first trimester of pregnancy. A key for the prevention of preeclampsia.

    Science.gov (United States)

    Tiralongo, G M; Lo Presti, D; Pisani, I; Gagliardi, G; Scala, R L; Novelli, G P; Vasapollo, B; Andreoli, A; Valensise, H

    2015-04-01

    Maternal cardiovascular system adapts to pregnancy, thanks to complex physiological mechanisms that involve cardiac output, total vascular resistance and water body distribution. Abnormalities of these adaptive mechanisms are connected with hypertensive disorders. To identify patients at a high risk of developing hypertensive complications of pregnancy during the first trimester of pregnancy, through the use of non-invasive methods such as USCOM (Ultrasonic Cardiac Output Monitor) and Bioimpedance. We enrolled 120 healthy normotensive women during the first trimester of pregnancy obtaining all measurements with the USCOM system and Bioimpedance. 20 patients were excluded for a bad USCOM signal. The remaining patients (n = 100) were retrospectively divided into two groups: Group A (n = 75) TVR1200 dynes s cm(-5). No statistically significant difference was identified in terms of water distribution, Fat Free Mass, Systolic/Diastolic Blood Pressure, Heart Rate, Hematocrit, Flow Time Corrected and Water Balance Index between the two groups. In contrast, higher values of the Cardiac Output, Stroke Volume, Fat Mass and Inotropy Index have been highlighted in the Group A. Moreover, in the Group A we found a better maternal-neonatal outcome and a lower incidence of hypertensive complications. High TVR during the first weeks of gestation may be an early marker of cardiovascular maladaptation more than the evaluation of water distribution and, in particular, with respect to the single blood pressure assessment. Moreover lower values of Inotropy Index could be an indicative of the worst cardiac performance. Copyright © 2015 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  3. Preoperative irradiation for prevention of heterotopic ossification following prosthetic total hip replacement. Results of a prospective study in 462 hips

    Energy Technology Data Exchange (ETDEWEB)

    Koelbl, O.; Seufert, J.; Pohl, F.; Flentje, M. [Univ. Wuerzburg (Germany). Klinik and Poliklinik for Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Hospital, Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Hospital, Bad Mergentheim (Germany). Inst. of Radiology

    2003-11-01

    Background: The effectiveness of pre- or postoperative radiotherapy for prevention of heterotopic ossification (HO) following total hip replacement (THR) has already been demonstrated in the past. Thereby, in most studies using preoperative radiotherapy patients were irradiated < 6 h before surgery. The purpose of this prospective study was to analyze the effectiveness of preoperative irradiation on the evening before surgery and to identify risk factors for HO in a homogeneous collective of patients. Patients and Methods: From July 1997 to July 2001, 416 patients (462 hips; 235 males, 227 females) received preoperative radiotherapy of the hip on the evening before surgery with a 7-Gy single fraction. The patients' median age was 67.1 years. The most frequent indication for radiotherapy was hypertrophic osteoarthritis (383 hips, 82.9%). Treatment results were assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). The analysis of radiographs was performed according to the Brooker score. Results: The overall incidence of HO was 18.1% (n = 84), Brooker score 1 12.3% (n = 57), score 2 3.9% (n = 18), score 3 1.5% (n = 7), and score 4 0.4% (n = 2). Sex, body height, hypertrophic osteoarthritis of higher degree, size of the femoral component of the prosthesis, previous ipsi- or contralateral HO, and short course of nonsteroidal anti-inflammatory drug (diclofenac) therapy significantly influenced the HO rate in univariate analysis. In multivariate analysis, an interdependence of prosthesis size, sex and patient's height was found. From these three variables, only prosthesis size was statistically significant in multivariate analysis. The cumulative dose of diclofenac ({<=} 300 mg or > 300 mg) within the first 7 postoperative days and previous ipsi- or contralateral HO influenced the incidence of HO in multivariate analysis. Conclusion: Preoperative radiotherapy on the evening before surgery is an effective treatment

  4. WE-EF-207-08: Improve Cone Beam CT Using a Synchronized Moving Grid, An Inter-Projection Sensor Fusion and a Probability Total Variation Reconstruction

    International Nuclear Information System (INIS)

    Zhang, H; Kong, V; Jin, J; Ren, L; Zhang, Y; Giles, W

    2015-01-01

    Purpose: To present a cone beam computed tomography (CBCT) system, which uses a synchronized moving grid (SMOG) to reduce and correct scatter, an inter-projection sensor fusion (IPSF) algorithm to estimate the missing information blocked by the grid, and a probability total variation (pTV) algorithm to reconstruct the CBCT image. Methods: A prototype SMOG-equipped CBCT system was developed, and was used to acquire gridded projections with complimentary grid patterns in two neighboring projections. Scatter was reduced by the grid, and the remaining scatter was corrected by measuring it under the grid. An IPSF algorithm was used to estimate the missing information in a projection from data in its 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct the initial CBCT image using projections after IPSF processing for pTV. A probability map was generated depending on the confidence of estimation in IPSF for the regions of missing data and penumbra. pTV was finally used to reconstruct the CBCT image for a Catphan, and was compared to conventional CBCT image without using SMOG, images without using IPSF (SMOG + FDK and SMOG + mask-TV), and image without using pTV (SMOG + IPSF + FDK). Results: The conventional CBCT without using SMOG shows apparent scatter-induced cup artifacts. The approaches with SMOG but without IPSF show severe (SMOG + FDK) or additional (SMOG + TV) artifacts, possibly due to using projections of missing data. The 2 approaches with SMOG + IPSF removes the cup artifacts, and the pTV approach is superior than the FDK by substantially reducing the noise. Using the SMOG also reduces half of the imaging dose. Conclusion: The proposed technique is promising in improving CBCT image quality while reducing imaging dose

  5. WE-EF-207-08: Improve Cone Beam CT Using a Synchronized Moving Grid, An Inter-Projection Sensor Fusion and a Probability Total Variation Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Kong, V; Jin, J [Georgia Regents University Cancer Center, Augusta, GA (Georgia); Ren, L; Zhang, Y; Giles, W [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To present a cone beam computed tomography (CBCT) system, which uses a synchronized moving grid (SMOG) to reduce and correct scatter, an inter-projection sensor fusion (IPSF) algorithm to estimate the missing information blocked by the grid, and a probability total variation (pTV) algorithm to reconstruct the CBCT image. Methods: A prototype SMOG-equipped CBCT system was developed, and was used to acquire gridded projections with complimentary grid patterns in two neighboring projections. Scatter was reduced by the grid, and the remaining scatter was corrected by measuring it under the grid. An IPSF algorithm was used to estimate the missing information in a projection from data in its 2 neighboring projections. Feldkamp-Davis-Kress (FDK) algorithm was used to reconstruct the initial CBCT image using projections after IPSF processing for pTV. A probability map was generated depending on the confidence of estimation in IPSF for the regions of missing data and penumbra. pTV was finally used to reconstruct the CBCT image for a Catphan, and was compared to conventional CBCT image without using SMOG, images without using IPSF (SMOG + FDK and SMOG + mask-TV), and image without using pTV (SMOG + IPSF + FDK). Results: The conventional CBCT without using SMOG shows apparent scatter-induced cup artifacts. The approaches with SMOG but without IPSF show severe (SMOG + FDK) or additional (SMOG + TV) artifacts, possibly due to using projections of missing data. The 2 approaches with SMOG + IPSF removes the cup artifacts, and the pTV approach is superior than the FDK by substantially reducing the noise. Using the SMOG also reduces half of the imaging dose. Conclusion: The proposed technique is promising in improving CBCT image quality while reducing imaging dose.

  6. Prevention

    Science.gov (United States)

    ... Contact Aging & Health A to Z Find a Geriatrics Healthcare Professional Medications & Older Adults Making Your Wishes ... Prevention Hearing Loss Heart Attack High Blood Pressure Nutrition Osteoporosis Shingles Skin Cancer Related News Quitting Smoking, ...

  7. Muscle-invasive bladder cancer treated with external beam radiation: influence of total dose, overall treatment time, and treatment interruption on local control

    International Nuclear Information System (INIS)

    Moonen, L.; Voet, H. van der; Nijs, R. de; Horenblas, S.; Hart, A.A.M.; Bartelink, H.

    1998-01-01

    Purpose: To evaluate and eventually quantify a possible influence of tumor proliferation during the external radiation course on local control in muscle invasive bladder cancer. Methods and Materials: The influence of total dose, overall treatment time, and treatment interruption has retrospectively been analyzed in a series of 379 patients with nonmetastasized, muscle-invasive transitional cell carcinoma of the urinary bladder. All patients received external beam radiotherapy at the Netherlands Cancer Institute between 1977 and 1990. Total dose varied between 50 and 75 Gy with a mean of 60.5 Gy and a median of 60.4 Gy. Overall treatment time varied between 20 and 270 days with a mean of 49 days and a median of 41 days. Number of fractions varied between 17 and 36 with a mean of 27 and a median of 26. Two hundred and forty-four patients had a continuous radiation course, whereas 135 had an intended split course or an unintended treatment interruption. Median follow-up was 22 months for all patients and 82 months for the 30 patients still alive at last follow-up. A stepwise procedure using proportional hazard regression has been used to identify prognostic treatment factors with respect to local recurrence as sole first recurrence. Results: One hundred and thirty-six patients experienced a local recurrence and 120 of these occurred before regional or distant metastases. The actuarial local control rate was 40.3% at 5 years and 32.3% at 10 years. In a multivariate analysis total dose showed a significant association with local control (p 0.0039), however in a markedly nonlinear way. In fact only those patients treated with a dose below 57.5 Gy had a significant higher bladder relapse rate, whereas no difference in relapse rate was found among patients treated with doses above 57.5 Gy. This remained the case even after adjustment for overall treatment time and all significant tumor and patient characteristics. The Normalized Tumor Dose (NTD) (α/β = 10) and NTD (

  8. Prevention

    DEFF Research Database (Denmark)

    Halken, S; Høst, A

    2001-01-01

    , breastfeeding should be encouraged for 4-6 months. In high-risk infants a documented extensively hydrolysed formula is recommended if exclusive breastfeeding is not possible for the first 4 months of life. There is no evidence for preventive dietary intervention neither during pregnancy nor lactation...... populations. These theories remain to be documented in proper, controlled and prospective studies. Breastfeeding and the late introduction of solid foods (>4 months) is associated with a reduced risk of food allergy, atopic dermatitis, and recurrent wheezing and asthma in early childhood. In all infants....... Preventive dietary restrictions after the age of 4-6 months are not scientifically documented....

  9. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M. [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1998-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  10. Use of the Braden Scale for pressure ulcer risk assessment in a community hospital setting: the role of total score and individual subscale scores in triggering preventive interventions.

    Science.gov (United States)

    Gadd, Molly M; Morris, Sarah M

    2014-01-01

    To determine whether pressure ulcer preventive interventions are implemented when a total Braden Scale score reflects that the patient is at risk. A retrospective chart review was completed for 20 patients with confirmed hospital-acquired pressure ulcers (HAPUs). A convenience sample of 20 patients with HAPUs confirmed by a certified wound nurse was systematically selected from 63 charts. The study setting was a 200-bed acute care facility in the Midwestern United States. A retrospective review of 20 patient charts was conducted. Data collected included daily Braden Scale scores and subscale scores, along with pressure ulcer preventive intervention implementation for at-risk (cumulative Braden Scale scores ≤ 18) and not-at-risk (cumulative Braden Scale scores > 18) days. Data were collected both before and after pressure ulcer occurrence. The occurrence of preventive interventions was compared between at-risk and not-at-risk patient days. Nineteen percent of not-at-risk patient days were found to have lower subscale scores, indicating a need for focused preventive interventions. The day before an HAPU occurred, the mean Braden Scale score was 13.7 ± 2.8 (mean ± SD) for those who were provided an intervention and 18.5 ± 2.3 for those not provided an intervention (t = 3.89, P = .001). Sixty-three percent of at-risk patients received some intervention the day before an HAPU occurred, while 20% of not-at-risk patients received some intervention. Routine use of a pressure ulcer risk assessment tool is considered necessary for a comprehensive pressure ulcer prevention program. Planning preventive care according to the subscale scores of the Braden Scale may be more effective for prevention of HAPUs in some cases.

  11. Total knee replacement induces peripheral blood lymphocytes apoptosis and it is not prevented by regional anesthesia - a randomized study.

    Science.gov (United States)

    Kosel, Juliusz; Rusak, Małgorzata; Gołembiewski, Łukasz; Dąbrowska, Milena; Siemiątkowski, Andrzej

    2016-01-01

    Among the many changes caused by a surgical insult one of the least studied is postoperative immunosuppression. This phenomenon is an important cause of infectious complications of surgery such as surgical site infection or hospital acquired pneumonia. One of the mechanisms leading to postoperative immunosuppression is the apoptosis of immunological cells. Anesthesia during surgery is intended to minimize harmful changes and maintain perioperative homeostasis. The aim of the study was evaluation of the effect of the anesthetic technique used for total knee replacement on postoperative peripheral blood lymphocyte apoptosis. 34 patients undergoing primary total knee replacement were randomly assigned to two regional anesthetic protocols: spinal anesthesia and combined spinal-epidural anesthesia. 11 patients undergoing total knee replacement under general anesthesia served as control group. Before surgery, immediately after surgery, during first postoperative day and seven days after the surgery venous blood samples were taken and the immunological status of the patient was assessed with the use of flow cytometry, along with lymphocyte apoptosis using fluorescent microscopy. Peripheral blood lymphocyte apoptosis was seen immediately in the postoperative period and was accompanied by a decrease of the number of T cells and B cells. There were no significant differences in the number of apoptotic lymphocytes according to the anesthetic protocol. Changes in the number of T CD3/8 cells and the number of apoptotic lymphocytes were seen on the seventh day after surgery. Peripheral blood lymphocyte apoptosis is an early event in the postoperative period that lasts up to seven days and is not affected by the choice of the anesthetic technique. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  12. [Total knee replacement induces peripheral blood lymphocytes apoptosis and it is not prevented by regional anesthesia - a randomized study].

    Science.gov (United States)

    Kosel, Juliusz; Rusak, Małgorzata; Gołembiewski, Łukasz; Dąbrowska, Milena; Siemiątkowski, Andrzej

    2016-01-01

    Among the many changes caused by a surgical insult one of the least studied is postoperative immunosuppression. This phenomenon is an important cause of infectious complications of surgery such as surgical site infection or hospital acquired pneumonia. One of the mechanisms leading to postoperative immunosuppression is the apoptosis of immunological cells. Anesthesia during surgery is intended to minimize harmful changes and maintain perioperative homeostasis. The aim of the study was evaluation the effect of the anesthetic technique used for total knee replacement on postoperative peripheral blood lymphocyte apoptosis. 34 patients undergoing primary total knee replacement were randomly assigned to two regional anesthetic protocols: spinal anesthesia and combined spinal-epidural anesthesia. 11 patients undergoing total knee replacement under general anesthesia served as control group. Before surgery, immediately after surgery, during first postoperative day and seven days after the surgery venous blood samples were taken and the immunological status of the patient was assessed with the use of flow cysts 87 m, along with lymphocyte apoptosis using fluorescent microscopy. Peripheral blood lymphocyte apoptosis was seen immediately in the postoperative period and was accompanied by a decrease of the number of T cells and B cells. There were no significant differences in the number of apoptotic lymphocytes according to the anesthetic protocol. Changes in the number of T CD3/8 cells and the number of apoptotic lymphocytes were seen on the seventh day after surgery. Peripheral blood lymphocyte apoptosis is an early event in the postoperative period lasts up to seven days and is not affected by the choice of the anesthetic technique. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  13. Use of Tranexamic acid is a cost effective method in preventing blood loss during and after total knee replacement

    Directory of Open Access Journals (Sweden)

    Umer Chaudhry Muhammad

    2011-05-01

    Full Text Available Abstract Background & Purpose Allogenic blood transfusion in elective orthopaedic surgery is best avoided owing to its associated risks. Total knee replacement often requires blood transfusion, more so when bilateral surgery is performed. Many strategies are currently being employed to reduce the amount of peri-operative allogenic transfusions. Anti-fibrinolytic compounds such as aminocaproic acid and tranexamic acid have been used systemically in perioperative settings with promising results. This study aimed to evaluate the effectiveness of tranexamic acid in reducing allogenic blood transfusion in total knee replacement surgery. Methodology This was a retrospective cohort study conducted on patients undergoing total knee replacement during the time period November 2005 to November 2008. Study population was 99 patients, of which 70 underwent unilateral and 29 bilateral knee replacement. Forty-seven patients with 62 (49.5% knees (group-I had received tranexamic acid (by surgeon preference while the remaining fifty-two patients with 66 (51.5% knees (group-II had did not received any tranexamic acid either pre- or post-operatively. Results The mean drop in the post-operative haemoglobin concentration in Group-II for unilateral and bilateral cases was 1.79 gm/dl and 2.21 gm/dl, with a mean post-operative drainage of 1828 ml (unilateral and 2695 ml (bilateral. In comparison, the mean drop in the post-op haemoglobin in Group-I was 1.49 gm/dl (unilateral and 1.94 gm/dl (bilateral, with a mean drainage of 826 ml (unilateral and 1288 ml (bilateral (p-value Interpretation Tranexamic acid is effective in reducing post-operative drainage and requirement of blood transfusion after knee replacement.

  14. Mechanical evaluation of adjunctive fixation for prevention of periprosthetic femur fracture with the Zurich cementless total hip prosthesis.

    Science.gov (United States)

    Pozzi, Antonio; Peck, Jeffrey N; Chao, Peini; Choate, Christina J; Barousse, Dan; Conrad, Bryan

    2013-06-01

    To evaluate whether cerclage wire or a lateral plate increases the peak-torque load to failure, compared to femora without adjunctive fixation, in femora implanted with Zurich Cementless stems. In vitro biomechanical study. Paired femora from adult dogs (n = 24) weighing 28-35 kg. Pairs of femora were implanted with a stem and randomly assigned to 2 treatment groups: cerclage or plate. Within each pair, either 3 loop cerclage wires or a laterally applied 12-hole Advanced Locking Plate System 10-mm plate (ALPS 10) were implanted in a femur, whereas the contralateral femur acted as control with no adjunctive fixation. After application of a static axial load each specimen was loaded to failure in torsion. Peak torque load at failure was compared between femora with each adjunctive fixation and the control using a paired t-test; P plated group (P plates and with cerclage were 13.9% and 7.2% stronger in torsion than the femora without fixation, respectively. Adjunctive fixation with a laterally applied ALPS 10 may aid in the prevention of peri-prosthetic fractures associated with Zurich Cementless medium stems. © Copyright 2013 by The American College of Veterinary Surgeons.

  15. Postoperative radiotherapy for prevention of heterotopic ossification following total hip arthroplasty; Postoperative Strahlentherapie zur Praevention heterotoper Ossifikationen nach endoprothetischem Hueftgelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Heyd, R. [Abt. fuer Strahlentherapie und Onkologie, Zentrum Radiologie, Klinikum J.-W.-Goethe-Universitaet, Frankfurt am Main (Germany); Strassmann, G. [Abt. fuer Strahlentherapie und Onkologie, Zentrum Radiologie, Klinikum J.-W.-Goethe-Universitaet, Frankfurt am Main (Germany); Kirchner, J. [Abt. fuer Roentgendiagnostik, Zentrum Radiologie, Klinikum J.-W.-Goethe-Universitaet, Frankfurt am Main (Germany); Schopohl, B. [Abt. fuer Strahlentherapie und Onkologie, Zentrum Radiologie, Klinikum J.-W.-Goethe-Universitaet, Frankfurt am Main (Germany); Boettcher, H.D. [Abt. fuer Strahlentherapie und Onkologie, Zentrum Radiologie, Klinikum J.-W.-Goethe-Universitaet, Frankfurt am Main (Germany)

    1996-10-01

    Following total hip arthroplasty high-grade heterotopic ossification occurs with a range of 0.5 to 27%. Local postoperative hip irradiation using different dosage and fractionation schedules reduces the incidence in high-risk cases on an average of 8%. The present retrospective study compares results after conventionally fractionated and high-dose radiotherapy. A total of 50 hips (46 patients) from 2 different risk groups had complete follow-up. In group I (40 hips [80.0%]) radiotherapy was indicated after surgical excision of pre-existing high-grade heterotopic ossification, in group II (10 hips [20.0%]) for several risk factors (contralateral heterotopic ossification [n=7], hypertrophic osteoarthritis [n=2], spondylosis hyperostotica [n=1]). In 28/50 cases (56.0%) conventionally fractionated irradiation with total doses ranging from 12.0 to 20.0 Gy was given, in 22/50 hips (44.0%) a high-dose irradiation consisting of 10.0 Gy given in 2 fractions on each of the first 2 postoperative days was applied. After a minimal observation period of 6 months (median: 22 months, range: 6 to 56 months) roentgenograms were analysed using a modified Brooker-score. At follow-up, 2 hips in group I had recurrence of high-grade heterotopic ossification with the stages IIIA and IVB. In 1 case radiotherapy was interrupted after 3x2.0 Gy due to sepsis (IIIA), in the other case ectopic bone recurred from bony islands which layed outside the radiation portal (IVB). In group II, 9 patients had stage 0 and 1 patient stage IA. Statistical analysis using the Wilcoxon-test showed a highly significant reduction of the amount of pre-existing heterotopic ossification (p<0.0001) for both fractionation schedules. The comparison of both fractionation groups with the Whitney-Mann-U-test (p=0.92) showed no statistical significant difference. (orig.) [Deutsch] Nach endoprothetischem Hueftgelenkersatz treten mit einer Spannbreite von 0,5 bis 27% hoehergradige heterotope Ossifikationen auf. Deren

  16. Melatonin prevents inflammation and oxidative stress caused by abdominopelvic and total body irradiation of rat small intestine.

    Science.gov (United States)

    Guney, Y; Hicsonmez, A; Uluoglu, C; Guney, H Z; Ozel Turkcu, U; Take, G; Yucel, B; Caglar, G; Bilgihan, A; Erdogan, D; Nalca Andrieu, M; Kurtman, C; Zengil, H

    2007-10-01

    We investigated the day-night differences in intestinal oxidative-injury and the inflammatory response following total body (TB) or abdominopelvic (AP) irradiation, and the influence of melatonin administration on tissue injury induced by radiation. Rats (male Wistar, weighing 220-280 g) in the irradiated groups were exposed to a dose of 8 Gy to the TB or AP region in the morning (resting period - 1 h after light onset) or evening (activity span - 13 h after light onset). Vehicle or melatonin was administered immediately before, immediately after and 24 h after irradiation (10, 2.0 and 10 mg/kg, ip, respectively) to the irradiated rats. AP (P < 0.05) and TB (P < 0.05) irradiation applied in the morning caused a significant increase in thiobarbituric acid reactive substance (TBARS) levels. Melatonin treatment in the morning (P < 0.05) or evening (P < 0.05) decreased TBARS levels after TB irradiation. After AP irradiation, melatonin treatment only in the morning caused a significant decrease in TBARS levels (P < 0.05). Although we have confirmed the development of inflammation after radiotherapy by histological findings, neither AP nor TB irradiation caused any marked changes in myeloperoxidase activity in the morning or evening. Our results indicate that oxidative damage is more prominent in rats receiving TB and AP irradiation in the morning and melatonin appears to have beneficial effects on oxidative damage irrespective of the time of administration. Increased neutrophil accumulation indicates that melatonin administration exerts a protective effect on AP irradiation-induced tissue oxidative injury, especially in the morning.

  17. Melatonin prevents inflammation and oxidative stress caused by abdominopelvic and total body irradiation of rat small intestine

    Directory of Open Access Journals (Sweden)

    Y. Guney

    2007-10-01

    Full Text Available We investigated the day-night differences in intestinal oxidative-injury and the inflammatory response following total body (TB or abdominopelvic (AP irradiation, and the influence of melatonin administration on tissue injury induced by radiation. Rats (male Wistar, weighing 220-280 g in the irradiated groups were exposed to a dose of 8 Gy to the TB or AP region in the morning (resting period - 1 h after light onset or evening (activity span - 13 h after light onset. Vehicle or melatonin was administered immediately before, immediately after and 24 h after irradiation (10, 2.0 and 10 mg/kg, ip, respectively to the irradiated rats. AP (P < 0.05 and TB (P < 0.05 irradiation applied in the morning caused a significant increase in thiobarbituric acid reactive substance (TBARS levels. Melatonin treatment in the morning (P < 0.05 or evening (P < 0.05 decreased TBARS levels after TB irradiation. After AP irradiation, melatonin treatment only in the morning caused a significant decrease in TBARS levels (P < 0.05. Although we have confirmed the development of inflammation after radiotherapy by histological findings, neither AP nor TB irradiation caused any marked changes in myeloperoxidase activity in the morning or evening. Our results indicate that oxidative damage is more prominent in rats receiving TB and AP irradiation in the morning and melatonin appears to have beneficial effects on oxidative damage irrespective of the time of administration. Increased neutrophil accumulation indicates that melatonin administration exerts a protective effect on AP irradiation-induced tissue oxidative injury, especially in the morning.

  18. Total period of weed interference prevention in lettuce cv. SolarisPeríodo total de prevenção a interferência das plantas daninhas na cultura da alface cultivar Solaris

    Directory of Open Access Journals (Sweden)

    Micheli Satomi Yamauti

    2010-02-01

    Full Text Available This research work aimed to determine the total period of interference of weeds prevention of lettuce cultivar Solaris. The experiment was conducted in Universidade Estadual de Londrina, in the period of autumn/ winter of 2008. The lettuce crop remained free from weed interference from emergence up to 0, 10, 20, 30, 40, 50 e 60 days. The experiment was arranged in a randomized block design with four replications. The weed community was composed by Bidens pilosa, Amaranthus hybridus, Oxalis corniculata, Euphorbia heterophylla, Spinacia oleracea, Commelina benghalensis e Lepidium virginicum. It was determined dry and fresh matter of weeds, and number of lettuce leaves. Assuming a tolerance of 5% for crop production decrease, it was verified that the total period of interference prevention (TPIP occurred up to 21 days after transplanting. Weed interference throughout the crop cycle reduced 25% of its yield.Este trabalho foi realizado com o objetivo de determinar o período total de prevenção à interferência (PTPI das plantas daninhas na cultura da alface do tipo crespa, cultivar Solaris. O experimento foi instalado na Universidade Estadual de Londrina, no período de outono/ inverno de 2008. A cultura permaneceu livre da interferência das plantas daninhas desde o transplante até: 0, 10, 20, 30, 40, 50 e 60 dias. O delineamento utilizado foi o de blocos casualizados com quatro repetições. A comunidade infestante da área foi composta principalmente de Bidens pilosa, Amaranthus hybridus, Oxalis corniculata, Euphorbia heterophylla, Spinacia oleracea, Commelina benghalensis e Lepidium virginicum. As massas seca e fresca das plantas daninhas e o número de folhas da cultura foram determinados. Admitindo-se 5% de tolerância na redução da produtividade da cultura, o período total de prevenção à interferência (PTPI ocorreu 21 dias após o transplante. A interferência das plantas daninhas durante todo o ciclo de vida da alface reduziu a

  19. Luminosity, beam monitoring and triggering for the CMS experiment and measurement of the total inelastic cross-section at √s = 7 TeV

    CERN Document Server

    Bell, Alan James

    The Compact Muon Solenoid (CMS) detector, situated on the Large Hadron Collider (LHC) ring is a multi-purpose detector designed to search for new physics phenomena, make precise measurements of known processes at previously untapped energies and look for hints of physics beyond the Standard Model. During the initial low luminosity stages, the Beam Scintillation Counter (BSC) sub-detector was vital in providing accurate and efficient ( 98%) triggering of beam halo and minimum bias events and helped in the commissioning of the CMS detector. This thesis is given in three parts. The first section describes the design and implementation of the BSC and the commissioning of the system before and during the early operation of the LHC. Analysis of the technical triggers it provided, using early low pile-up data in shown to demonstrate that the goal of providing an efficient trigger for low luminosities was achieved. Demonstrations of its use beyond its intended design are also shown, which helped drive the need for an...

  20. Direct, indirect, total, and overall effectiveness of the rotavirus vaccines for the prevention of gastroenteritis hospitalizations in privately insured US children, 2007-2010.

    Science.gov (United States)

    Panozzo, Catherine A; Becker-Dreps, Sylvia; Pate, Virginia; Weber, David J; Jonsson Funk, Michele; Stürmer, Til; Brookhart, M Alan

    2014-04-01

    We demonstrate how direct, indirect, total, and overall effectiveness estimates and absolute benefits of rotavirus vaccines vary through the years following vaccine introduction. Privately insured US children in a large claims database were followed from age 8 months until they 1) experienced a hospitalization for rotavirus or acute gastroenteritis; 2) lost continuous health plan enrollment; 3) turned 20 months of age; or 4) reached the end of the study period. Vaccine effectiveness estimates in preventing rotavirus and acute gastroenteritis hospitalizations were estimated using Cox proportional hazards regression, stratified by calendar year and adjusted for birth month. Incidence rate differences were estimated to determine the absolute number of gastroenteritis hospitalizations prevented in the cohort. Among 905,718 children, 51%, 66%, 80%, and 86% received 1 or more doses of rotavirus vaccine in each year from 2007 to 2010. The direct vaccine effectiveness of 1 or more doses of rotavirus vaccine in preventing rotavirus gastroenteritis hospitalizations ranged from 87% to 92% each year. Accounting for indirect protection increased estimates of vaccine effectiveness by an additional 3%-8% among those vaccinated. Failing to account for population-level vaccine benefits in 2010, when circulation of rotavirus was low, could underestimate the sustained impact of the vaccine program.

  1. Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging.

    Science.gov (United States)

    Zeng, Gengsheng L

    2013-10-01

    This aim of this paper is to revisit the parallel-beam/cone-beam or fan-beam/cone-beam imaging configuration, and to investigate whether this configuration has any advantages. Twenty years ago, it was suggested to simultaneously use a parallel-beam (or a fan-beam) collimator and a cone-beam collimator to acquire single photon emission computed tomography data. The motivation was that the parallel-beam (or the fan-beam) collimator can provide sufficient sampling, while the cone-beam collimator is able to provide higher photon counts. Even with higher total counts, this hybrid system does not give significant improvement (if any) in terms of image noise and artifacts reduction. If a conventional iterative maximum-likelihood expectation-maximization algorithm is used to reconstruct the image, the resultant reconstruction may be worse than the parallel-beam-only (or fan-beam-only) system. This paper uses the singular value decomposition (SVD) analysis to explain this phenomenon. The SVD results indicate that the parallel-beam-only and the fan-beam-only system outperform the combined systems. The optimal imaging system does not necessary to be the one that generates the projections with highest signal-to-noise ratio and best resolution.

  2. Ionizing radiation and autoimmunity: Induction of autoimmune disease in mice by high dose fractionated total lymphoid irradiation and its prevention by inoculating normal T cells

    International Nuclear Information System (INIS)

    Sakaguchi, N.; Sakaguchi, S.; Miyai, K.

    1992-01-01

    Ionizing radiation can functionally alter the immune system and break self-tolerance. High dose (42.5 Gy), fractionated (2.5 Gy 17 times) total lymphoid irradiation (TLI) on mice caused various organ-specific autoimmune diseases, such as gastritis, thyroiditis, and orchitis, depending on the radiation dosages, the extent of lymphoid irradiation, and the genetic background of the mouse strains. Radiation-induced tissue damage is not the primary cause of the autoimmune disease because irradiation of the target organs alone failed to elicit the autoimmunity and shielding of the organs from irradiation was unable to prevent it. In contrast, irradiation of both the thymus and the peripheral lymphoid organs/tissues was required for efficient induction of autoimmune disease by TLI. TLI eliminated the majority of mature thymocytes and the peripheral T cells for 1 mo, and inoculation of spleen cell, thymocyte, or bone marrow cell suspensions (prepared from syngeneic nonirradiated mice) within 2 wk after TLI effectively prevented the autoimmune development. Depletion of T cells from the inocula abrogated the preventive activity. CD4 + T cells mediated the autoimmune prevention but CD8 + T cells did not. CD4 + T cells also appeared to mediate the TLI-induced autoimmune disease because CD4 + T cells from disease-bearing TLI mice adoptively transferred the autoimmune disease to syngeneic naive mice. Taken together, these results indicate that high dose, fractionated ionizing radiation on the lymphoid organs/tissues can cause autoimmune disease by affecting the T cell immune system, rather than the target self-Ags, presumably by altering T cell-dependent control of self-reactive T cells. 62 refs., 9 figs., 2 tabs

  3. Whether preventive low dose magnesium sulphate infusion has an influence on postoperative pain perception and the level of serum beta-endorphin throughout the total abdominal hysterectomy.

    Science.gov (United States)

    Haryalchi, K; Abedinzade, M; Khanaki, K; Mansour Ghanaie, M; Mohammad Zadeh, F

    Due to the known role of preventive low dose magnesium sulphate on postoperative pain management, in this randomized, double-blinded, placebo-controlled study, we tried to investigate the possible relationship between low dose intra-operative magnesium sulphate infusion, postoperative analgesia and the level of serum beta-endorphin during total abdominal hysterectomy under general anesthesia. Forty women undergoing total abdominal hysterectomy were randomly allocated into 2 groups (20 in each arm). Fifteen minutes before induction of anaesthesia, the case group received a continuous intravenous infusion of magnesium sulphate (15mg/kg/h) and placebo control group received the same volume of isotonic saline. Pain scores were assessed at 0, 6, 12, and 24h after operations using Verbal Numeric Rating Scale. Pethidine consumption was recorded precisely. Serum level of beta-endorphin just 15min before the induction and at the end of the operations was determined by ELISA technique. At 6 and 12h after the operations, Verbal Numeric Rating Scale in the case group was significantly lower than that of placebo control group (P=.0001). Over 24h after the operations, pethidine consumption was significantly lower in the case group compared with control group (P=.0001). In the case group, serum level of beta-endorphin was significantly decreased at the end of the operations compared with before the induction (P=.04). We illustrated that preventive low dose intra-operative magnesium sulphate infusion reduces postoperative pain, has opioid sparing effect and declines serum beta-endorphin concentration during total abdominal hysterectomy. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Preliminary results of a randomized trial comparing 400 cGy vs 700 cGy as an adjuvant to prevent heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Nguyen, Cam; Gupta-Burt, Shalina; Silverton, Craig; Cummings, Marilyn; Galante, Jorge O.

    1997-01-01

    Purpose/Objective: We report our preliminary results of a randomized trial comparing one single dose of 400 cGy versus 700 cGy given postoperatively in an attempt to prevent heterotopic ossification after total hip arthroplasty. Materials and Methods: From 09/1993 and 05/1996, over 800 total hip replacements were performed at our hospital. From this group of patients, 120 hips in 114 high-risk patients (14%) were enrolled in a randomized trial to determine if 400 cGy (Group A) is as efficacious as 700 cGy (Group B) in preventing heterotopic ossification. In Group A, there were 42 males (46 hips) and 12 females (12 hips) with a mean age of 60 (range 41-79); with 18 primary cementless femoral components (33%), 30 primary cemented stems (55%) and 10 revisions. In Group B, there were 30 males (32 hips) and 30 females (31 hips) with a median age of 59 (range 41-85); with 12 primary cementless femoral components (20%), 44 primary cemented stems (73%) and 6 revisions. All acetabular components were of the cementless type. Patients were randomized to receive either 400 cGy or 700 cGy in one fraction. Radiotherapy is given within 48 hours post-operatively using paired anterior and posterior fields, with blocking of the cementless acetabular component and the femoral component. Results: All 114 patients were available for a minimum follow-up of 6 months (range 6-30 months). None of the arthroplasties has failed at the latest follow-up. There were no radiation therapy complications noted. Statistical analysis revealed no difference in the distribution of patients in either group according to age, sex, primary or revision arthroplasty, cemented or cementless femoral component fixation, preoperative heterotopic ossification risk, or surgical approach. Of the 58 hips in Group A, heterotopic ossification was graded as Grade 0 in 24 hips, Grade I in 10 hips, Grade II in 18 hips, Grade III in 6 hips, with no cases of Grade IV. Of the 63 hips in Group B, heterotopic ossification was

  5. Determination of the total neutron cross section for natural hafnium on the filtered neutron beam with 2 keV energy

    Directory of Open Access Journals (Sweden)

    О. О. Gritzay

    2017-12-01

    Full Text Available Unshielded value of the total neutron cross section of the natHf at the neutron 2 keV energy was obtained. The MCNP 4С code and measurement results obtained with using six samples for thicknesses from 0.00236 to 0.01257 nucl/b were used for determination of the unshielded value of the natHf cross section. Obtained value of the total neutron cross section of the natHf was compared with the data of other authors and with data from the evaluated nuclear data libraries.

  6. LHC Report: Towards stable beams and collisions

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    Over the past two weeks, the LHC re-commissioning with beam has continued at a brisk pace. The first collisions of 2011 were produced on 2 March, with stable beams and collisions for physics planned for the coming days. Low intensity beams with just a few bunches of particles were used to test the energy ramp to 3.5 TeV and the squeeze. The results were successful and, as a by-product, the first collisions of 2011 were recorded 2 March. One of the main activities carried out by the operation teams has been the careful set-up of the collimation system, and the injection and beam dump protection devices. The collimation system provides essential beam cleaning, preventing stray particles from impacting other elements of the machine, particularly the superconducting magnets. In addition to the collimation system, also the injection and beam dump protection devices perform a vital machine protection role, as they detect any beam that might be mis-directed during rare, but not totally unavoidable, hardware hiccups...

  7. Clinical Performance of the 1st American Academy of Orthopaedic Surgeons Clinical Guideline on Prevention of Symptomatic Pulmonary Embolism after Total Knee Arthroplasty in Korean Patients.

    Science.gov (United States)

    Na, Young Gon; Fang, Rui; Kim, Yeon Ho; Cho, Kwan Jae; Kim, Tae Kyun

    2015-12-01

    We sought to document the clinical performance of the 1st American Academy of Orthopaedic Surgeons (AAOS) guideline on the prevention of symptomatic pulmonary embolism (PE) after total knee arthroplasty (TKA) in Korean patients, in terms of the proportions of the each risk-stratified group, efficacy and safety. Consecutive 328 patients underwent TKA were preoperatively assessed for the risks of PE and bleeding and categorized into 4 groups: 1) standard risk, 2) high risk for PE, 3) high risk for bleeding, and 4) high risks both for PE and bleeding. One of three options was administered according to the groups (aspirin in group 1 or 4; enoxaparin and following aspirin in group 2; antithrombotic stocking in group 3). Incidences of symptomatic deep vein thrombosis (DVT) and PE, and major or minor bleeding complications were evaluated. Majority of the patients (86%) were assessed to be with standard risks both for PE and bleeding. No patient experienced symptomatic DVT or PE and major bleeding. Eleven percent of the patients discontinued chemoprophylaxis because of bleeding-related wound complication. In conclusion, the 1st AAOS guideline functions successfully in Korean patients undergoing TKA in terms of prevention of symptomatic DVT and PE while avoiding major bleeding complications.

  8. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de

    2017-01-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  9. Depressed collector for electron beams

    Science.gov (United States)

    Ives, R. Lawrence (Inventor)

    2005-01-01

    A depressed collector for recovery of spent beam energy from electromagnetic sources emitting sheet or large aspect ration annular electron beams operating aver a broad range of beam voltages and currents. The collector incorporates a trap for capturing and preventing the return of reflected and secondary electrons.

  10. Who needs hyperon beams

    International Nuclear Information System (INIS)

    Lipkin, H.J.

    1976-01-01

    Hyperon beams can provide new interesting information about hadron structure and their strong, electromagnetic and weak interactions. The dependence of hadron interactions on strangeness and baryon number is not understood, and data from hyperon beams can provide new clues to paradoxes which arise in the interpretation of data from conventional beams. Examples of interesting data are total and differential cross sections, magnetic moments and values of Gsub(A)/Gsub(V) for weak semileptonic decays. (author)

  11. Turmeric (Curcuma longa L.) extract may prevent the deterioration of spatial memory and the deficit of estimated total number of hippocampal pyramidal cells of trimethyltin-exposed rats.

    Science.gov (United States)

    Yuliani, Sapto; Mustofa; Partadiredja, Ginus

    2018-01-01

    Protection of neurons from degeneration is an important preventive strategy for dementia. Much of the dementia pathology implicates oxidative stress pathways. Turmeric (Curcuma longa L.) contains curcuminoids which has anti-oxidative and neuro-protective effects. These effects are considered to be similar to those of citicoline which has been regularly used as one of standard medications for dementia. This study aimed at investigating the effects of turmeric rhizome extract on the hippocampus of trimethyltin (TMT)-treated Sprague-Dawley rats. The rats were divided randomly into six groups, i.e., a normal control group (N); Sn group, which was given TMT chloride; Sn-Cit group, which was treated with citicoline and TMT chloride; and three Sn-TE groups, which were treated with three different dosages of turmeric rhizome extract and TMT chloride. Morris water maze test was carried out to examine the spatial memory. The estimated total number of CA1 and CA2-CA3 pyramidal cells was calculated using a stereological method. The administration of turmeric extract at a dose of 200 mg/kg bw has been shown to prevent the deficits in the spatial memory performance and partially inhibit the reduction of the number of CA2-CA3 regions pyramidal neurons. TMT-induced neurotoxic damage seemed to be mediated by the generation of reactive oxygen species and reactive nitrogen species. Turmeric extract might act as anti inflammatory as well as anti-oxidant agent. The effects of turmeric extract at a dose of 200 mg/kg bw seem to be comparable to those of citicoline.

  12. [Double-blind randomized comparative study of enoxaparin and standard heparin in the prevention of thromboembolic disease during insertion of total hip replacement].

    Science.gov (United States)

    Planes, A; Vochelle, N; Mazas, F; Mansat, C; Zucman, G; Landais, A; Weill, D; Pascariello, J C; Butel, J

    1988-01-01

    237 patients with a non-traumatic disease of the hip requiring total hip replacement entered a multicentre trial. Treatments were allocated at random in a double-blind manner: 113 patients received 5000 IU of standard heparin t.d.s.; 124 patients received enoxaparin 40 mg once a day. Treatment lasted from 10 to 15 days until bilateral ascending phlebography of the lower limbs (BAPLL) was performed. Its effectiveness was assessed by the results of BAPLL, by evaluation of the risk of bleeding on examination of the surgical wound, by the units of blood required for perfusion and by daily blood count and differential. BAPLL was performed in 228 patients: 15 phlebographies (12.5 p. 100) were positive in the 120 assessed patients of the enoxaparin group, while 27 (25 p. 100) were positive in the 108 assessed patients of the standard heparin group (p = 0.014). Proximal deep vein thrombosis was significantly (p = 0.03) less frequent in the enoxaparin group (7.5 p. 100) than in the standard heparin group (18.5 p. 100). Pulmonary embolism was observed in a patient on standard heparin. The units of blood required for perfusion were significantly (p = 0.03) smaller in the enoxaparin group (3.37 +/- 1.81 U) than in the standard heparin group (3.84 +/- 1.70 U). Thus, one single subcutaneous injection of enoxaparin 40 mg daily was significantly more effective and safer than standard heparin 5000 IU t.d.s. in the prevention of deep vein thrombosis after total hip replacement.

  13. Efficacy of Myofascial Trigger Point Dry Needling in the Prevention of Pain after Total Knee Arthroplasty: A Randomized, Double-Blinded, Placebo-Controlled Trial

    Science.gov (United States)

    Mayoral, Orlando; Salvat, Isabel; Martín, María Teresa; Martín, Stella; Santiago, Jesús; Cotarelo, José; Rodríguez, Constantino

    2013-01-01

    The aim of this study was to determine whether the dry needling of myofascial trigger points (MTrPs) is superior to placebo in the prevention of pain after total knee arthroplasty. Forty subjects were randomised to a true dry needling group (T) or to a sham group (S). All were examined for MTrPs by an experienced physical therapist 4–5 hours before surgery. Immediately following anesthesiology and before surgery started, subjects in the T group were dry needled in all previously diagnosed MTrPs, while the S group received no treatment in their MTrPs. Subjects were blinded to group allocation as well as the examiner in presurgical and follow-up examinations performed 1, 3, and 6 months after arthroplasty. Subjects in the T group had less pain after intervention, with statistically significant differences in the variation rate of the visual analogue scale (VAS) measurements 1 month after intervention and in the need for immediate postsurgery analgesics. Differences were not significant at 3- and 6-month follow-up examinations. In conclusion, a single dry needling treatment of MTrP under anaesthesia reduced pain in the first month after knee arthroplasty, when pain was the most severe. Results show a superiority of dry needling versus placebo. An interesting novel placebo methodology for dry needling, with a real blinding procedure, is presented. PMID:23606888

  14. Prevention of postoperative venous thrombosis: a randomized trial comparing unfractionated heparin with low molecular weight heparin in patients undergoing total hip replacement.

    Science.gov (United States)

    Planes, A; Vochelle, N; Mazas, F; Mansat, C; Zucman, J; Landais, A; Pascariello, J C; Weill, D; Butel, J

    1988-12-22

    A double blind randomized trial comparing subcutaneous enoxaparin (40 mg once daily) with standard unfractionated calcium heparin administered at a dose of 5,000 units every 8 hours in patients undergoing elective hip replacement has been performed. Treatment regimens began 12 hours preoperatively with enoxaparin, 2 hours preoperatively with standard unfractionated calcium heparin, and were continued for 15 days or until discharge. Venography was performed in all patients. Two hundred thirty-seven patients were included in the study: 113 received unfractionated heparin and 124 received enoxaparin. The incidence of proximal deep vein thrombosis was reduced from 18.5% in the unfractionated heparin group to 7.5% in the enoxaparin group (p = 0.014), and the incidence of total deep vein thrombosis was similarly reduced from 25% to 12.5% (p = 0.03). There were two major bleeding episodes and one minor bleed in the enoxaparin group compared to two minor bleeds in the unfractionated heparin group. Patients who received enoxaparin required fewer red blood cell transfusions and had a significantly higher hemoglobin on postoperative days 3 and 4. Thus prophylaxis with enoxaparin, 40 mg once daily, is simple, safe and more effective than standard low dose unfractionated heparin in preventing deep vein thrombosis in patients undergoing elective hip replacement.

  15. Coherent beam-beam effects

    International Nuclear Information System (INIS)

    Chao, A.W.

    1992-01-01

    There are two physical pictures that describe the beam-beam interaction in a storage ring collider: The weak-strong and the strong-strong pictures. Both pictures play a role in determining the beam-beam behavior. This review addresses only the strong-strong picture. The corresponding beam dynamical effects are referred to as the coherent beam-beam effects. Some basic knowledge of the weak-strong picture is assumed. To be specific, two beams of opposite charges are considered. (orig.)

  16. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2011-11-01

    Full Text Available zones capable of introducing a phase shift of zero or p on the alternately out of phase rings of the TEMp0 beams into a unified phase and then focusing the rectified beam to generate a high resolution beam which has a Gaussian beam intensity distribution...

  17. Beam-beam and impedance

    CERN Document Server

    White, S.

    2014-07-17

    As two counter-rotating beams interact they can give rise to coherent dipole modes. Under the influence of impedance these coherent beam-beam modes can couple to higher order head-tail modes and lead to strong instabilities. A fully self-consistent approach including beam-beam and impedance was used to characterize this new coupled mode instability and study possible cures such as a transverse damper and high chromaticity.

  18. Prevention of venous thromboembolism with an oral factor Xa inhibitor, YM150, after total hip arthroplasty. A dose finding study (ONYX-2)

    NARCIS (Netherlands)

    Eriksson, B. I.; Turpie, A. G. G.; Lassen, M. R.; Prins, M. H.; Agnelli, G.; Kälebo, P.; Wetherill, G.; Wilpshaar, J. W.; Meems, L.; Paireddy, A.; Wall, M.; Hermus, G.; Willems, M.; Zachrisson, B.; Wallin, J.; Eriksson, H.; Sandgren, G.; Angerås, U.; Falk, A.; Bergqvist, D.; Gallus, A.; Tijssen, J. G. P.; Pessayre, D.; Grohs, J. G.; Nogler, M.; Wurnig, C.; Gavrankapetanovic, I.; Maric, V.; Pavic, V.; Deniger, J.; Kofránek, I.; Pink, M.; Pink, T.; Hölmich, P.; Mejdahl, S.; Mikkelsen, S.; Leppilahti, J.; Pesola, M.; Fink, B.; Göbel, F.; Graichen, H.; Halder, A. M.; Kienapfel, H.; Kurth, A.; Ferrousis, I.; Macheras, G.; D'Angelo, A.; Baudo, F.; Borghi, B.; Della Rocca, G.; Fanelli, G.; Grappiolo, G.; Grossi, P.; Piovella, F.; Silingardi, M.; Spotorno, L.; Baurovskis, A.; Keselis, J.; Peredistijs, A.; Kocius, M.; Smailys, A.; Buciuto, R.; Hedlund, T.; Talsnes, O.; Bednarek, A.; Blacha, J.; Kwiatkowski, K.; Niedzwiedzki, T.; Skowronski, J. C.; Wojciechowski, P.; Dryagin, V.; Ivanov, P.; Kopenkin, S.; Kuropatkin, G.; Lapshinov, E.; Levin, G.; Linnik, S.; Medvedev, A.; Nikolaev, V.; Safronov, A.; Sergeev, S.; Harhaji, V.; Kecojevic, V.; Mitkovic, M.; Nedeljkovic, R.; Ristic, B.; Stosic, P.; Todorovic, P.; Hlavác, M.; Oslanec, D.; Alonso Aguirre, M. A.; Casa Pantoja, V.; Cruz Pardos, A.; Díaz Almodovar, J. L.; Gomar Sancho, F.; Otero Fernández, R.; Valle Ortiz, M. J.; Vilanova Vázquez, J. L.; Ahnfelt, L.; Andersson, C.; Petersson, L.-G.; Ponzer, S.

    2010-01-01

    BACKGROUND: Anticoagulant prophylaxis substantially reduces the risk of venous thromboembolism (VTE) after major orthopedic surgery. The direct factor Xa inhibitor YM150 is currently under investigation for the prevention of VTE, stroke and ischemic vascular events in patients after orthopedic

  19. Total skin electron beam therapy followed by adjuvant psoralen/ultraviolet-a light in the management of patients with T1 and T2 cutaneous T-cell lymphoma (mycosis fungoides)

    International Nuclear Information System (INIS)

    Quiros, Peter A.; Jones, Glenn W.; Kacinski, Barry M.; Braverman, Irwin M.; Heald, Peter W.; Edelson, Richard L.; Wilson, Lynn D.

    1997-01-01

    Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m 2 , 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per month. There were 39 T1 and 75 T2 patients. Six T1 (15%) and eight T2 (11%) patients were treated with adjuvant PUVA. A further 49% of the 114 patients received adjuvant systemic therapy, 3% received spot external beam, 4% received adjuvant ECP, 2% received topical nitrogen mustard, 22% received a combination of therapies exclusive of PUVA, and 9% received no adjuvant therapy. Patients were balanced in all subgroups based on pre-TSEBT therapy. The median age of the cohort was 58 (range 20-88), with a median follow-up time of 62 months (range 3-179). Results: Within 1 month after completing of TSEBT, 97% of T1, and 87% of T2 patients had achieved a complete remission. Stratified by adjuvant therapy, none of six T1 and one of eight T2 patients who received adjuvant PUVA failed within the first 3 years after completion of TSEBT. A total of 43% of the T1 and T2 patients receiving other or no adjuvant treatment failed within the same time course. The 5-year OS for the entire cohort was 85%. Those who received PUVA had a 5-year OS of 100% versus a 5-year OS for the non

  20. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-02

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  1. Beam cooling

    OpenAIRE

    Danared, H

    2006-01-01

    Beam cooling is the technique of reducing the momentum spread and increasing the phase-space density of stored particle beams. This paper gives an introduction to beam cooling and Liouville’s theorem, and then it describes the three methods of active beam cooling that have been proven to work so far, namely electron cooling, stochastic cooling, and laser cooling. Ionization cooling is also mentioned briefly.

  2. Molecular beams

    International Nuclear Information System (INIS)

    Pendelbury, J.M.; Smith, K.F.

    1987-01-01

    Studies with directed collision-free beams of particles continue to play an important role in the development of modern physics and chemistry. The deflections suffered by such beams as they pass through electric and magnetic fields or laser radiation provide some of the most direct information about the individual constituents of the beam; the scattering observed when two beams intersect yields important data about the intermolecular forces responsible for the scattering. (author)

  3. AVE5026, a new hemisynthetic ultra-low-molecular-weight heparin for the prevention of venous thromboembolism in patients after total knee replacement surgery

    DEFF Research Database (Denmark)

    Lassen, Michael Rud; Dahl, O E; Mismetti, P

    2009-01-01

    BACKGROUND: AVE5026 is a new hemisynthetic ultra-low-molecular-weight heparin, with a novel anti-thrombotic profile resulting from high anti-factor (F)Xa activity and residual anti-FIIa activity. AVE5026 is in clinical development for venous thromboembolism (VTE) prevention, a frequent complication...

  4. Beam diagnostics

    International Nuclear Information System (INIS)

    Bogaty, J.; Clifft, B.E.; Zinkann, G.P.; Pardo, R.C.

    1995-01-01

    The ECR-PII injector beam line is operated at a fixed ion velocity. The platform high voltage is chosen so that all ions have a velocity of 0.0085c at the PII entrance. If a previous tune configuration for the linac is to be used, the beam arrival time must be matched to the previous tune as well. A nondestructive beam-phase pickup detector was developed and installed at the entrance to the PII linac. This device provides continuous phase and beam current information and allows quick optimization of the beam injected into PII. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum interface where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam-induced radiofrequency signals are summed against an offset frequency generated by our master oscillator. The resulting kilohertz difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop which stabilizes phase readings if beam is unstable. The other channel uses a linear full wave active rectifier circuit which converts kilohertz sine wave signal amplitude to a D.C. voltage representing beam current. A prototype set of electronics is now in use with the detector and we began to use the system in operation to set the arrival beam phase. A permanent version of the electronics system for the phase detector is now under construction. Additional nondestructive beam intensity and phase monitors at the open-quotes Boosterclose quotes and open-quotes ATLASclose quotes linac sections are planned as well as on some of the high-energy beam lines. Such a monitor will be particularly useful for FMA experiments where the primary beam hits one of the electric deflector plates

  5. Limitations due to strong head-on beam-beam interactions (MD 1434)

    CERN Document Server

    Buffat, Xavier; Iadarola, Giovanni; Papadopoulou, Parthena Stefania; Papaphilippou, Yannis; Pellegrini, Dario; Pojer, Mirko; Crockford, Guy; Salvachua Ferrando, Belen Maria; Trad, Georges; Barranco Garcia, Javier; Pieloni, Tatiana; Tambasco, Claudia; CERN. Geneva. ATS Department

    2017-01-01

    The results of an experiment aiming at probing the limitations due to strong head on beam-beam interactions are reported. It is shown that the loss rates significantly increase when moving the working point up and down the diagonal, possibly due to effects of the 10th and/or 14th order resonances. Those limitations are tighter for bunches with larger beam-beam parameters, a maximum total beam-beam tune shift just below 0.02 could be reached.

  6. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  7. Finite element modelling of composite castellated beam

    Directory of Open Access Journals (Sweden)

    Frans Richard

    2017-01-01

    Full Text Available Nowadays, castellated beam becomes popular in building structural as beam members. This is due to several advantages of castellated beam such as increased depth without any additional mass, passing the underfloor service ducts without changing of story elevation. However, the presence of holes can develop various local effects such as local buckling, lateral torsional buckling caused by compression force at the flange section of the steel beam. Many studies have investigated the failure mechanism of castellated beam and one technique which can prevent the beam fall into local failure is the use of reinforced concrete slab as lateral support on castellated beam, so called composite castellated beam. Besides of preventing the local failure of castellated beam, the concrete slab can increase the plasticity moment of the composite castellated beam section which can deliver into increasing the ultimate load of the beam. The aim of this numerical studies of composite castellated beam on certain loading condition (monotonic quasi-static loading. ABAQUS was used for finite element modelling purpose and compared with the experimental test for checking the reliability of the model. The result shows that the ultimate load of the composite castellated beam reached 6.24 times than the ultimate load of the solid I beam and 1.2 times compared the composite beam.

  8. Design for low beam loss in accelerators for intense neutron source applications

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1993-01-01

    Control of beam loss in intense ion linacs involves keeping beam spill below parts in 10 -5 --10 -8 /m by preventing total beam size from extending to the limiting apertures. Starting from good rms design practices, new analysis of the machine architecture is described in terms of the effects of the machine tune with space-charge, free-energy constraint, and halo-producing mechanisms. It is shown that halos are produced by the time- (or position-) varying nature of common linac aspects (such as misalignment, mismatching, acceleration, and construction techniques) through collective core/single-particle interaction dynamics plus resonances

  9. LHC Beam Instrumentation: Beam Profile Measurements (2/3)

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  10. Elliptical beams.

    Science.gov (United States)

    Bandres, Miguel A; Gutiérrez-Vega, Julio C

    2008-12-08

    A very general beam solution of the paraxial wave equation in elliptic cylindrical coordinates is presented. We call such a field an elliptic beam (EB). The complex amplitude of the EB is described by either the generalized Ince functions or the Whittaker-Hill functions and is characterized by four parameters that are complex in the most general situation. The propagation through complex ABCD optical systems and the conditions for square integrability are studied in detail. Special cases of the EB are the standard, elegant, and generalized Ince-Gauss beams, Mathieu-Gauss beams, among others.

  11. Direct, Indirect, Total, and Overall Effectiveness of the Rotavirus Vaccines for the Prevention of Gastroenteritis Hospitalizations in Privately Insured US Children, 2007–2010

    OpenAIRE

    Panozzo, Catherine A.; Becker-Dreps, Sylvia; Pate, Virginia; Weber, David J.; Jonsson Funk, Michele; Stürmer, Til; Brookhart, M. Alan

    2014-01-01

    We demonstrate how direct, indirect, total, and overall effectiveness estimates and absolute benefits of rotavirus vaccines vary through the years following vaccine introduction. Privately insured US children in a large claims database were followed from age 8 months until they 1) experienced a hospitalization for rotavirus or acute gastroenteritis; 2) lost continuous health plan enrollment; 3) turned 20 months of age; or 4) reached the end of the study period. Vaccine effectiveness estimates...

  12. Stroboscopic image capture: Reducing the dose per frame by a factor of 30 does not prevent beam-induced specimen movement in paraffin

    Energy Technology Data Exchange (ETDEWEB)

    Typke, Dieter [Life Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Gilpin, Christopher J. [Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, TX 75390 (United States); Downing, Kenneth H. [Life Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glaeser, Robert M. [Life Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States) and Department of Molecular and Cell Biology, University of California, Berkeley, CA 94720 (United States)]. E-mail: rmglaeser@lbl.gov

    2007-02-15

    Beam-induced specimen movement may be the major factor that limits the quality of high-resolution images of organic specimens. One of the possible measures to improve the situation that was proposed by Henderson and Glaeser [Ultramicroscopy 16 (1985) 139-150], which we refer to here as 'stroboscopic image capture', is to divide the normal exposure into many successive frames, thus reducing the amount of electron exposure-and possibly the amount of beam-induced movement-per frame. The frames would then be aligned and summed. We have performed preliminary experiments on stroboscopic imaging using a 200-kV electron microscope that was equipped with a high dynamic range Charge-coupled device (CCD) camera for image recording and a liquid N{sub 2}-cooled cryoholder. Single-layer paraffin crystals on carbon film were used as a test specimen. The ratio F(g)/F(0) of paraffin reflections, calculated from the images, serves as our criterion for the image quality. In the series that were evaluated, no significant improvement of the F {sub image}(g)/F {sub image}(0) ratio was found, even though the electron exposure per frame was reduced by a factor of 30. A frame-to-frame analysis of image distortions showed that considerable beam-induced movement had still occurred during each frame. In addition, the paraffin crystal lattice was observed to move relative to the supporting carbon film, a fact that cannot be explained as being an electron-optical effect caused by specimen charging. We conclude that a significant further reduction of the dose per frame (than was possible with this CCD detector) will be needed in order to test whether the frame-to-frame changes ultimately become small enough for stroboscopic image capture to show its potential.

  13. Stroboscopic image capture: Reducing the dose per frame by a factor of 30 does not prevent beam-induced specimen movement in paraffin

    International Nuclear Information System (INIS)

    Typke, Dieter; Gilpin, Christopher J.; Downing, Kenneth H.; Glaeser, Robert M.

    2007-01-01

    Beam-induced specimen movement may be the major factor that limits the quality of high-resolution images of organic specimens. One of the possible measures to improve the situation that was proposed by Henderson and Glaeser [Ultramicroscopy 16 (1985) 139-150], which we refer to here as 'stroboscopic image capture', is to divide the normal exposure into many successive frames, thus reducing the amount of electron exposure-and possibly the amount of beam-induced movement-per frame. The frames would then be aligned and summed. We have performed preliminary experiments on stroboscopic imaging using a 200-kV electron microscope that was equipped with a high dynamic range Charge-coupled device (CCD) camera for image recording and a liquid N 2 -cooled cryoholder. Single-layer paraffin crystals on carbon film were used as a test specimen. The ratio F(g)/F(0) of paraffin reflections, calculated from the images, serves as our criterion for the image quality. In the series that were evaluated, no significant improvement of the F image (g)/F image (0) ratio was found, even though the electron exposure per frame was reduced by a factor of 30. A frame-to-frame analysis of image distortions showed that considerable beam-induced movement had still occurred during each frame. In addition, the paraffin crystal lattice was observed to move relative to the supporting carbon film, a fact that cannot be explained as being an electron-optical effect caused by specimen charging. We conclude that a significant further reduction of the dose per frame (than was possible with this CCD detector) will be needed in order to test whether the frame-to-frame changes ultimately become small enough for stroboscopic image capture to show its potential

  14. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2012-07-01

    Full Text Available positions of p zeros of intensity distributions on the Gaussian beam, resulting to a generation of TEMp0 beams where there are minimum losses. The LGBs are well-known family of exact orthogonal solutions of free-space paraxial wave equation in cylindrical...

  15. Beam diagnostics

    CERN Document Server

    Raich, U

    2008-01-01

    Most beam measurements are based on the electro-magnetic interaction of fields induced by the beam with their environment. Beam current transformers as well as beam position monitors are based on this principle. The signals induced in the sensors must be amplified and shaped before they are converted into numerical values. These values are further treated numerically in order to extract meaningful machine parameter measurements. The lecture introduces the architecture of an instrument and shows where in the treatment chain digital signal analysis can be introduced. Then the use of digital signal processing is presented using tune measurements, orbit and trajectory measurements as well as beam loss detection and longitudinal phase space tomography as examples. The hardware as well as the treatment algorithms and their implementation on Digital Signal Processors (DSPs) or in Field Programmable Gate Arrays (FPGAs) are presented.

  16. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  17. Who Must We Target Now to Minimize Future Cardiovascular Events and Total Mortality?: Lessons From the Surveillance, Prevention and Management of Diabetes Mellitus (SUPREME-DM) Cohort Study.

    Science.gov (United States)

    Desai, Jay R; Vazquez-Benitez, Gabriela; Xu, Zhiyuan; Schroeder, Emily B; Karter, Andrew J; Steiner, John F; Nichols, Gregory A; Reynolds, Kristi; Xu, Stanley; Newton, Katherine; Pathak, Ram D; Waitzfelder, Beth; Lafata, Jennifer Elston; Butler, Melissa G; Kirchner, H Lester; Thomas, Abraham; O'Connor, Patrick J

    2015-09-01

    Examining trends in cardiovascular events and mortality in US health systems can guide the design of targeted clinical and public health strategies to reduce cardiovascular events and mortality rates. We conducted an observational cohort study from 2005 to 2011 among 1.25 million diabetic subjects and 1.25 million nondiabetic subjects from 11 health systems that participate in the Surveillance, Prevention and Management of Diabetes Mellitus (SUPREME-DM) DataLink. Annual rates (per 1000 person-years) of myocardial infarction/acute coronary syndrome (International Classification of Diseases-Ninth Revision, 410.0–410.91, 411.1–411.8), stroke (International Classification of Diseases-Ninth Revision, 430–432.9, 433–434.9), heart failure (International Classification of Diseases-Ninth Revision, 428–428.9), and all-cause mortality were monitored by diabetes mellitus (DM) status, age, sex, race/ethnicity, and a prior cardiovascular history. We observed significant declines in cardiovascular events and mortality rates in subjects with and without DM. However, there was substantial variation by age, sex, race/ethnicity, and prior cardiovascular history. Mortality declined from 44.7 to 27.1 (P<0.0001) for those with DM and cardiovascular disease (CVD), from 11.2 to 10.9 (P=0.03) for those with DM only, and from 18.9 to 13.0 (P<0.0001) for those with CVD only. Yet, in the [almost equal to]85% of subjects with neither DM nor CVD, overall mortality (7.0 to 6.8; P=0.10) and stroke rates (1.6–1.6; P=0.77) did not decline and heart failure rates increased (0.9–1.15; P=0.0005). To sustain improvements in myocardial infarction, stroke, heart failure, and mortality, health systems that have successfully focused on care improvement in high-risk adults with DM or CVD must broaden their improvement strategies to target lower risk adults who have not yet developed DM or CVD.

  18. Efficacy in Deep Vein Thrombosis Prevention With Extended Mechanical Compression Device Therapy and Prophylactic Aspirin Following Total Knee Arthroplasty: A Randomized Control Trial.

    Science.gov (United States)

    Snyder, Mark A; Sympson, Alexandra N; Scheuerman, Christina M; Gregg, Justin L; Hussain, Lala R

    2017-05-01

    Aspirin at 325 mg twice daily is now included as a nationally approved venous thromboembolism (VTE) prophylaxis protocol for low-risk total knee arthroplasty (TKA) patients. The purpose of this study is to examine whether there is a difference in deep vein thrombosis (DVT) occurrence after a limited tourniquet TKA using aspirin-based prophylaxis with or without extended use of mechanical compression device (MCD) therapy. One hundred limited tourniquet TKA patients, whose DVT risk was managed with aspirin 325 mg twice daily for 3 weeks, were randomized to either using an MCD during hospitalization only or extended use at home up to 6 weeks postoperatively. Lower extremity duplex venous ultrasonography (LEDVU) was completed on the second postoperative day, 14 days postoperatively, and at 3 months postoperatively to confirm the absence of DVT after treatment. The DVT rate for the postdischarge MCD therapy group was 0% and 23.1% for the inpatient MCD group (P aspirin for 3 weeks postoperatively, and on MCD therapy for up to 6 weeks postoperatively experienced superior DVT prophylaxis than patients receiving MCD therapy only as an inpatient (P aspirin and extended-use MCD further validates this type of prophylaxis in low DVT risk TKA patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  20. Molecular beams

    International Nuclear Information System (INIS)

    Ramsey, N.F.

    1985-01-01

    This book is a timeless and rather complete theoretical and experimental treatment of electric and magnetic resonance molecular-beam experiments for studying the radio frequency spectra of atoms and molecules. The theory of interactions of the nucleus with atomic and molecular fields is extensively presented. Measurements of atomic and nuclear magnetic moments, electric multipole moments, and atomic fine and hyperfine structure are detailed. Useful but somewhat outdated chapters on gas kinetics, molecular beam design, and experimental techniques are also included

  1. Beam transport

    International Nuclear Information System (INIS)

    1988-01-01

    Considerable experience has now been gained with the various beam transport lines, and a number of minor changes have been made to improve the ease of operation. These include: replacement of certain little-used slits by profile monitors (harps or scanners); relocation of steering magnets, closer to diagnostic harps or profile scanners; installation of a scanner inside the isocentric neutron therapy system; and conversion of a 2-doublet quadrupole telescope (on the neutron therapy beamline) to a 2-triplet telescope. The beam-swinger project has been delayed by very late delivery of the magnet iron to the manufacturer, but is now progressing smoothly. The K=600 spectrometer magnets have now been delivered and are being assembled for field mapping. The x,y-table with its associated mapping equipment is complete, together with the driver software. One of the experimental areas has been dedicated to the production of collimated neutron beams and has been equipped with a bending magnet and beam dump, together with steel collimators fixed at 4 degrees intervals from 0 degrees to 16 degrees. Changes to the target cooling and shielding system for isotope production have led to a request for much smaller beam spot sizes on target, and preparations have been made for rearrangement of the isotope beamline to permit installation of quadrupole triplets on the three beamlines after the switching magnet. A practical system of quadrupoles for matching beam properties to the spectrometer has been designed. 6 figs

  2. Faraday Cup - it is used to measure beam intensities at low energy beams.

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    A Faraday Cup is used to measure beam intensities at low energy beams. An electrically isolated metallic electrode intercepts the beam and captures all its charges. These charges are integrated using an current sensitive amplifier. When the beam impinges onto the electrode surface low energy electrons are liberated. In order to prevent these electrons from escaping the cup and thus falsifying the measurement, a repeller electrode with negative potential pushes the electrons back onto the electrode.

  3. FMECA Application to Intraoperative Electron Beam Radiotherapy Procedure As a Quality Method to Prevent and Reduce Patient’s Risk in Conservative Surgery for Breast Cancer

    Directory of Open Access Journals (Sweden)

    Cristiana Vidali

    2017-08-01

    Full Text Available IntroductionFailure Mode Effects and Criticalities Analysis (FMECA represents a prospective method for risk assessment in complex medical practices. Our objective was to describe the application of FMECA approach to intraoperative electron beam radiotherapy (IOERT, delivered using a mobile linear accelerator, for the treatment of early breast cancer as an anticipated boost.Materials and methodsA multidisciplinary Working Group, including several different professional profiles, was created before the beginning of clinical practice in 2012, with the purpose of writing the Flow Chart and applying the FMECA methodology to IOERT procedure. Several criticalities were identified a priori in the different steps of the procedure and a list of all potential failure modes (FMs was drafted and ranked using the risk priority number (RPN scoring system, based on the product of three parameters: severity, occurrence, and detectability (score between 1 and 5. The actions aimed at reducing the risk were then defined by the Working Group and the risk analysis was repeated in 2014 and in 2016, in order to assess the improvement achieved.ResultsFifty-one FMs were identified, which represented the issues prospectively investigated according to the FMECA methodology. Considering a set threshold of 30, the evaluated RPNs show that 33 out of 51 FMs are critical; 6 are included in the moderate risk class (RPN: 31–40; 16 in the intermediate risk class (RPN: 41–50, and 11 in the high risk class (RPN: >50.DiscussionThe most critical steps concerned the surgical procedure and IOERT set-up. The introduction of the corrective actions into the clinical practice achieved the reduction of the RPNs in the re-analysis of the FMECA worksheet after 2 and 4 years, respectively.ConclusionFMECA proved to be a useful tool for prospective evaluation of potential failures in IOERT and contributed to optimize patient safety and to improve risk management culture among all the

  4. Quantum beams

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru

    2003-01-01

    Present state and future prospect are described on quantum beams for medical use. Efforts for compactness of linac for advanced cancer therapy have brought about the production of machines like Accuray's CyberKnife and TOMOTHERAPY (Tomo Therapy Inc.) where the acceleration frequency of X-band (9-11 GHz) is used. For cervical vein angiography by the X-band linac, a compact hard X-ray source is developed which is based on the (reverse) Compton scattering through laser-electron collision. More intense beam and laser are necessary at present. A compact machine generating the particle beam of 10 MeV-1 GeV (laser-plasma accelerator) for cancer therapy is also developed using the recent compression technique (chirped-pulse amplification) to generate laser of >10 TW. Tokyo University is studying for the electron beam with energy of GeV order, for the laser-based synchrotron X-ray, and for imaging by the short pulse ion beam. Development of advanced compact accelerators is globally attempted. In Japan, a virtual laboratory by National Institute of Radiological Sciences (NIRS), a working group of universities and research facilities through the Ministry of Education, Culture, Sports, Science and Technology, started in 2001 for practical manufacturing of the above-mentioned machines for cancer therapy and for angiography. Virtual Factory (Inc.), a business venture, is to be stood in future. (N.I.)

  5. Hybrid beams in the LHC

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    The first proton-ion beams were successfully circulated in the LHC a couple of weeks ago. Everything went so smoothly that the LHC teams had planned the first p-Pb collisions for Wednesday, 16 November. Unfortunately, a last-minute problem with a component of the PS required for proton acceleration prevented the LHC teams from making these new collisions. However, the way is open for a possible physics run with proton-lead collisions in 2012.   Members of the LHC team photographed when the first hybrid beams got to full energy. The proton and lead beams are visible on the leftmost screen up on the wall (click to enlarge the photo). The technical challenge of making different beams circulate in the LHC is by no means trivial. Even if the machine is the same, there are a number of differences when it is operated with beams of protons, beams of lead or beams of proton and lead. Provided that the beams are equal, irrespective of whether they consist of protons or lead nuclei, they revolve at the...

  6. BEAM-BEAM SIMULATIONS FOR DOUBLE-GAUSSIAN BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    MONTAG, C.; MALITSKY, N.; BEN-ZVI, I.; LITVINENKO, V.

    2005-05-16

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-gaussian beams. Here we report the effect of low-frequency random tune modulations on diffusion in double-gaussian beams and compare the effects to those in beam-beam interactions with regular gaussian beams and identical tune shift parameters.

  7. BEAM-BEAM SIMULATIONS FOR DOUBLE-GAUSSIAN BEAMS

    International Nuclear Information System (INIS)

    MONTAG, C.; MALITSKY, N.; BEN-ZVI, I.; LITVINENKO, V.

    2005-01-01

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-gaussian beams. Here we report the effect of loW--frequency random tune modulations on diffusion in double-gaussian beams and compare the effects to those in beam-beam interactions with regular gaussian beams and identical tune shift parameters

  8. Beam-Beam Simulations for Double-Gaussian Beams

    CERN Document Server

    Montag, Christoph; Litvinenko, Vladimir N; Malitsky, Nikolay

    2005-01-01

    Electron cooling together with intra-beam scattering results in a transverse distribution that can best be described by a sum of two Gaussians, one for the high-density core and one for the tails of the distribution. Simulation studies are being performed to understand the beam-beam interaction of these double-Gaussian beams. Here we report the effect of low-frequency random tune modulations on diffusion in double-Gaussian beams and compare the effects to those in beam-beam interactions with regular Gaussian beams and identical tuneshift parameters.

  9. Beam current sensor

    Science.gov (United States)

    Kuchnir, Moyses; Mills, Frederick E.

    1987-01-01

    A current sensor for measuring the DC component of a beam of charged particles employs a superconducting pick-up loop probe, with twisted superconducting leads in combination with a Superconducting Quantum Interference Device (SQUID) detector. The pick-up probe is in the form of a single-turn loop, or a cylindrical toroid, through which the beam is directed and within which a first magnetic flux is excluded by the Meisner effect. The SQUID detector acts as a flux-to-voltage converter in providing a current to the pick-up loop so as to establish a second magnetic flux within the electrode which nulls out the first magnetic flux. A feedback voltage within the SQUID detector represents the beam current of the particles which transit the pick-up loop. Meisner effect currents prevent changes in the magnetic field within the toroidal pick-up loop and produce a current signal independent of the beam's cross-section and its position within the toroid, while the combination of superconducting elements provides current measurement sensitivites in the nano-ampere range.

  10. Design of HELIOS beam diagnostics

    International Nuclear Information System (INIS)

    Seagrave, J.D.; Bigio, I.J.; Jackson, S.V.; Laird, A.M.

    1979-01-01

    Verification of satisfactory operation of the HELIOS eight-beam laser system requires measurement of many parameters of each beam on each shot. Fifty-joule samples of each of the eight 1250-J, subnanosecond 34-cm-diameter beams of the HELIOS system are diverted to a gallery of eight folded telescopes and beamsplit to provide diagnostic measurements. Total pulse energy, and prepulse and postlase energy of each beam are measured; pulse shape details and a wavelength spectrum of a selected beam from each shot are measured; and provision is made for retropulse measurement and optical quality monitoring. All data are recorded digitally in a local screen room, with control and communication through a fiberoptic link to the main HELIOS computer

  11. Proton beam therapy facility

    International Nuclear Information System (INIS)

    1984-01-01

    It is proposed to build a regional outpatient medical clinic at the Fermi National Accelerator Laboratory (Fermilab), Batavia, Illinois, to exploit the unique therapeutic characteristics of high energy proton beams. The Fermilab location for a proton therapy facility (PTF) is being chosen for reasons ranging from lower total construction and operating costs and the availability of sophisticated technical support to a location with good access to patients from the Chicago area and from the entire nation. 9 refs., 4 figs., 26 tabs

  12. A pencil beam algorithm for helium ion beam therapy.

    Science.gov (United States)

    Fuchs, Hermann; Strobele, Julia; Schreiner, Thomas; Hirtl, Albert; Georg, Dietmar

    2012-11-01

    To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10(7) ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy fall off of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a γ-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the γ-index criterion was exceeded in some areas giving a maximum γ-index of 1.75 and 4.9% of the voxels showed γ-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient

  13. Beam dynamics for induction accelerators

    International Nuclear Information System (INIS)

    Lee, Edward P.

    2014-01-01

    An induction linac uses pulsed power that is applied directly, without any intervening resonant cavities, to accelerate a charged particle pulse. This approach can accommodate a large multiple-beam focusing lattice capable of transporting a large total beam current with a long pulse duration, which may be compressed while accelerating as well as afterward. The mean accelerating gradient is relatively low (less than about 1.5 MV/m), but the potential efficiency of energy transfer can be large up to about 50%. A multiple-beam induction linac is therefore a natural candidate accelerator for a heavy ion fusion (HIF) driver. However, the accelerated beams must meet stringent requirements on occupied phase space volume in order to be focused accurately and with small radius onto the fusion target. Dynamical considerations in the beam injector and linac, as well as in the final compression, final focus, and the fusion chamber, determine the quality of the driver beams as they approach the target. Requirements and tolerances derived from beam dynamics strongly influence the linac configuration and component design. After a summary of dynamical considerations, two major topics are addressed here: transportable current limits, which determine the choice of focal system for the linac, and longitudinal control of the beams, which are potentially destabilized by their interaction with the pulsed power system

  14. Noninterceptive transverse-beam measurements

    International Nuclear Information System (INIS)

    Chamberlin, D.D.; Minerbo, G.N.; Mottershead, C.T.

    1981-01-01

    Totally noninterceptive techniques for accurate measurement of transverse beam distributions are required for high-current continuous wave (cw) linacs, such as the Fusion Materials Irradiation Test (FMIT) accelerator. Sensors responding to visible radiation from beam interactions with residual gas and computer algorithms reconstructing spatial and phase space distributions have been implemented. This paper reports on early measurements of the beam from the injector of the prototype FMIT facility at Los Alamos. The first section indicates hardware setup and performance whereas the second section describes the data-processing software. The third section outlines the resultant measurements and further developments are discussed in the fourth section

  15. Beam transport

    International Nuclear Information System (INIS)

    1988-01-01

    The beam diagnostic components for both the transfer and the high-energy beamlines perform well except for some of the scanners whose noise pick-up has become a problem, especially at low beam intensities. This noise pick-up is primarily due to deterioration of the bearings in the scanner. At some locations in the high-energy beamlines, scanners were replaced by harps as the scanners proved to be practically useless for the low-intensity beams required in the experimental areas. The slits in the low-energy beamline, which are not water-cooled, have to be repaired at regular intervals because of vacuum leaks. Overheating causes the ceramic feedthroughs to deteriorate resulting in the vacuum leaks. Water-cooled slits have been ordered to replace the existing slits which will later be used in the beamlines associated with the second injector cyclotron SPC2. The current-measurement system will be slightly modified and should then be much more reliable. 3 figs

  16. Multi-layered controllable stiffness beams for morphing: energy, actuation force, and material strain considerations

    International Nuclear Information System (INIS)

    Murray, Gabriel; Gandhi, Farhan

    2010-01-01

    Morphing aerospace structures could benefit from the ability of structural elements to transition from a stiff load-bearing state to a relatively compliant state that can undergo large deformation at low actuation cost. The present paper focuses on multi-layered beams with controllable flexural stiffness—comprising polymer layers affixed to the surfaces of a base beam and cover layers, in turn, affixed to the surfaces of the polymer layers. Heating the polymer through the glass transition reduces its shear modulus, decouples the cover layers from the base beam and reduces the overall flexural stiffness. Although the stiffness and actuation force required to bend the beam reduce, the energy required to heat the polymer layer must also be considered. Results show that for beams with low slenderness ratios, relatively thick polymer layers, and cover layers whose extensional stiffness is high, the decoupling of the cover layers through softening of the polymer layers can result in flexural stiffness reductions of over 95%. The energy savings are also highest for these configurations, and will increase as the deformation of the beam increases. The decoupling of the cover layers from the base beam through the softening of the polymer reduces the axial strains in the cover layers significantly; otherwise material failure would prevent large deformation. Results show that when the polymer layer is stiff, the cover layers are the dominant contributors to the total energy in the beam, and the energy in the polymer layers is predominantly axial strain energy. When the polymer layers are softened the energy in the cover layers is a small contributor to the total energy which is dominated by energy in the base beam and shear strain energy in the polymer layer

  17. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  18. Accelerator Based Neutron Beams for Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yanch, Jacquelyn C.

    2003-04-11

    compared the RBE characteristics of the MIT Reactor M67 clinical beam, The Brookhaven Medical Research Reactor clinical beam (both of which were used in Phase I/II clinical trials of BNCT) and the MIT LABA BNCS beam. Additional research initiated under this program involved an investigation of the potential of BNCT for the prevention of restenosis and the development of accelerator-based fast neutron brachytherapy. A total of 10 student research theses (2 Undergraduate, 4 Masters, and 4 Doctoral) were completed as part of this research program.

  19. Cervical Total Disc Arthroplasty

    OpenAIRE

    Basho, Rahul; Hood, Kenneth A.

    2012-01-01

    Symptomatic adjacent segment degeneration of the cervical spine remains problematic for patients and surgeons alike. Despite advances in surgical techniques and instrumentation, the solution remains elusive. Spurred by the success of total joint arthroplasty in hips and knees, surgeons and industry have turned to motion preservation devices in the cervical spine. By preserving motion at the diseased level, the hope is that adjacent segment degeneration can be prevented. Multiple cervical disc...

  20. Beam divergence scaling in neutral beam injectors

    International Nuclear Information System (INIS)

    Holmes, A.J.T.

    1976-01-01

    One of the main considerations in the design of neutral beam injectors is to monimize the divergence of the primary ion beam and hence maximize the beam transport and minimize the input of thermal gas. Experimental measurements of the divergence of a cylindrical ion beam are presented and these measurements are used to analyze the major components of ion beam divergence, namely: space charge expansion, gas-ion scattering, emittance and optical aberrations. The implication of these divergence components in the design of a neutral beam injector system is discussed and a method of maximizing the beam current is described for a given area of source plasma

  1. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  2. THE RHIC BEAM ABORT KICKER SYSTEM

    International Nuclear Information System (INIS)

    Hahn, H.

    1999-01-01

    THE ENERGY STORED IN THE RHIC BEAM IS ABOUT 200 KJ PER RING AT DESIGN ENERGY AND INTENSITY. TO PREVENT QUENCHING OF THE SUPERCONDUCTING MAGNETS OR MATERIAL DAMAGE, THE BEAM WILL BE SAFELY DISPOSED OF BY AN INTERNAL BEAM ABORT SYSTEM, WHICH INCLUDES THE KICKER MAGNETS, THE PULSED POWER SUPPLIES, AND THE DUMP ABSORBER. DISPOSAL OF HEAVY IONS, SUCH AS GOLD, IMPOSES DESIGN CONSTRAINTS MORE SEVERE THAN THOSE FOR PROTON BEAMS OF EQUAL INTENSITY. IN ORDER TO MINIMIZE THE THERMAL SHOCK IN THE CARBON-FIBER DUMP BLOCK, THE BUNCHES MUST BE LATERALLY DISPERSED

  3. Experimental observations and theoretical models for beam-beam phenomena

    International Nuclear Information System (INIS)

    Kheifets, S.

    1981-03-01

    The beam-beam interaction in storage rings exhibits all the characteristics of nonintegrable dynamical systems. Here one finds all kinds of resonances, closed orbits, stable and unstable fixed points, stochastic layers, chaotic behavior, diffusion, etc. The storage ring itself being an expensive device nevertheless while constructed and put into operation presents a good opportunity of experimentally studying the long-time behavior of both conservative (proton machines) and nonconservative (electron machines) dynamical systems - the number of bunch-bunch interactions routinely reaches values of 10 10 -10 11 and could be increased by decreasing the beam current. At the same time the beam-beam interaction puts practical limits for the yield of the storage ring. This phenomenon not only determines the design value of main storage ring parameters (luminosity, space charge parameters, beam current), but also in fact prevents many of the existing storage rings from achieving design parameters. Hence, the problem has great practical importance along with its enormous theoretical interest. A brief overview of the problem is presented

  4. Electron beam fusion targets

    International Nuclear Information System (INIS)

    Clauser, M.J.; Sweeney, M.A.

    1975-01-01

    R The behavior of the DT filled gold shells when irradiated by a variety of pulse shapes was studied. In these pulses the power (and beam current) was varied, but the voltage was kept constant at 1 MeV. In general the performance of the target, for a given peak power, was not significantly affected by the pulse shape. Pulses with rise times of up to half the implosion time do not significantly degrade the target performance. The use of the ''optimal pulse'' of laser fusion with a fixed peak power does not appear to improve the performance of these targets. The main function of the ''optimal pulse'' is to produce a large rho r of the target during the thermonuclear burn. In e-beam targets a total rho r of 5--10 g/cm 2 can be obtained without pulse shaping; the problem here is one of achieving high enough temperatures to ignite the DT. (U.S.)

  5. Beam screens for the LHC beam pipes

    CERN Multimedia

    Patrice Loïez

    1997-01-01

    Cross-section of LHC prototype beam pipes showing the beam screens. Slits in the screens allow residual gas molecules to be pumped out and become frozen to the walls of the ultra-cold beam pipe. Beam screens like these have been designed to line the beam pipes, absorbing radiation before it can hit the magnets and warm them up, an effect that would greatly reduce the magnetic field and cause serious damage.

  6. Beam geometry selection using sequential beam addition.

    Science.gov (United States)

    Popple, Richard A; Brezovich, Ivan A; Fiveash, John B

    2014-05-01

    The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. For situations in which beam geometry has a significant effect on the objective function, SBA can identify arrangements equivalent to equiangular

  7. Beam geometry selection using sequential beam addition

    Energy Technology Data Exchange (ETDEWEB)

    Popple, Richard A., E-mail: rpopple@uabmc.edu; Brezovich, Ivan A.; Fiveash, John B. [Department of Radiation Oncology, The University of Alabama at Birmingham, 1720 2nd Avenue South, Birmingham, Alabama 35294 (United States)

    2014-05-15

    Purpose: The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. Methods: The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. Results: In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. Conclusions: For situations in which beam geometry has a significant effect on the objective function, SBA can identify

  8. Beam experiment at TARN

    International Nuclear Information System (INIS)

    Noda, A.; Chida, K.; Hattori, T.

    1984-01-01

    TARN is a storage ring of low energy ions (T sub(N) -- 10 MeV/u) constructed in 1979 to verify the feasibility of intensity multiplication proposed at NUMATRON project. The mean radius and maximum magnetic rigidity of the ring are 5.06 m and 11.8 kG.m, respectively. Magnet system based on a strong focusing FODO lattice is composed of 8 dipole and 16 quadrupole magnets. Additional 12 sextupole magnets are also installed for chromaticity control. Intensity increase by the multi-turn injection is 20 times with the dilution factor of 2.0 in horizontal transverse phase space. Injected beams are RF captured with the frequency around 8 MHz and moved inner side of the ring by RF deceleration as large as -- 5 % in Δp/p. Beam intensity increases linearly up to around 20 stackings with the capture efficiency of 80 % and 30 Hz repetition rate. Dilution factor of the longitudinal phase space is measured at 1.8. Thus about 300 times total intensity increase has been attained. The e-folding beam life time of 7 MeV proton is measured at 400 s for the vacuum pressure of 1 x 10 -10 Torr. Stochastic momentum cooling experiment of 7 MeV proton has been performed. A feed-back system based on the 'Notch-Filter' method has been adopted for its simplicity and characteristics suitable for lower beam intensity. Cooling time for the 7 MeV proton beam with the intensity of 10 8 is estimated at 19 s for optimum cooling rate with the system gain of 105 dB, while the system gain as large as 111 dB has been achieved without self-oscillation of the electronics system. From the beam experiment, the cooling time of 10 8 proton beam with fractional momentum spread of 1.4 x 10 -2 is measured at --20 sec with the system gain of 97 db. (author)

  9. Prevention of heterotopic bone formation with early post operative irradiation in high risk patients undergoing total hip arthroplasty: comparison of 10.00 Gy vs 20.00 Gy schedules

    International Nuclear Information System (INIS)

    Anthony, P.; Keys, H.; Evarts, C.M.; Rubin, P.; Lush, C.

    1987-01-01

    Prior studies have demonstrated the effectiveness of postoperative radiation therapy (RT) to the hip area following total hip replacement (THR) surgery in preventing the development of heterotopic bone formation in patients considered to be at high risk for development of this complication. Previously, patients received 20.00 Gy in 10 fractions (fx) over 2 weeks, beginning as soon postop as medically feasible (usually post-op day 2). In an effort to reduce hospital stay and risk of secondary malignancy, a prospective treatment program was initiated April 1982 using a reduced dose of 10.00 Gy in 5 fx over 5-7 days. As of February 1984, 46 consecutive hips determined to be at high risk were treated with this reduced dose. Prior studies have demonstrated that heterotopic bone is always radiographically evident by 8 weeks. Of the 46 hips, 41 had been evaluated with the minimum required 8 week follow-up X ray. Twenty-five of these hips, 61%, had a mean long term follow-up of 12 months. It historical control group, consisting of 54 consecutive high risk post-THR's, was shown to have a 68.5% incidence of heterotopic bone. The 20.00 Gy group, when RT was started by post-op day 5, demonstrated a 3.2% incidence, compared to 4.9% in the 10.00 Gy group. Complication rates were also comparable in the two RT groups, 19.4% and 7.3% respectively; 10.00 Gy is apparently as effective as 20.00 Gy in preventing heterotopic bone formation in high risk post-THR patients

  10. Effect of an integrated intervention package of preventive chemotherapy, community-led total sanitation and health education on the prevalence of helminth and intestinal protozoa infections in Côte d'Ivoire.

    Science.gov (United States)

    Hürlimann, Eveline; Silué, Kigbafori D; Zouzou, Fabien; Ouattara, Mamadou; Schmidlin, Thomas; Yapi, Richard B; Houngbedji, Clarisse A; Dongo, Kouassi; Kouadio, Bernadette A; Koné, Siaka; Bonfoh, Bassirou; N'Goran, Eliézer K; Utzinger, Jürg; Acka-Douabélé, Cinthia A; Raso, Giovanna

    2018-02-27

    Preventive chemotherapy with donated anthelminthic drugs is the cornerstone for the control of helminthiases. However, reinfection can occur rapidly in the absence of clean water and sanitation coupled with unhygienic behaviour. The purpose of this study was to assess the effect of an integrated package of interventions, consisting of preventive chemotherapy, community-led total sanitation (CLTS) and health education, on the prevalence of helminth and intestinal protozoa infections and on participants' knowledge, attitude, practice and beliefs (KAPB) towards these diseases including water, sanitation and hygiene (WASH). A cross-sectional survey was carried out in nine communities of south-central Côte d'Ivoire to assess people's infection with helminths and intestinal protozoa and KAPB. Subsequently, interventions were targeted to five communities, while the remaining communities served as control. The intervention encouraged latrine construction and an evaluation was done 6-7 months later to determine open defecation status of the respective communities. Anthelminthic treatment was provided to all community members. A follow-up cross-sectional survey was conducted approximately one year later, using the same procedures. Overall, 810 people had complete baseline and follow-up data and were given anthelminthic treatment. The baseline prevalence of hookworm, Schistosoma haematobium, Trichuris trichiura, Schistosoma mansoni and Ascaris lumbricoides was 31.1%, 7.0%, 2.0%, 1.0% and 0.3%, respectively. Four of the five intervention communities were classified open-defecation free. For hookworm infection, we observed higher negative changes in terms of proportion of decrease (-0.10; 95% confidence interval (CI): - 0.16, -0.04) and higher egg reduction rate (64.9 vs 15.2%) when comparing intervention with control communities. For intestinal protozoa, prevalence reduction was higher in intervention compared to control communities (8.2 vs 2.6%) and WASH indicators and

  11. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  12. First years experience of LHC Beam Instrumentation

    CERN Document Server

    Jones, O R

    2011-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. This paper will comment on all of these systems and on their contributions to the various stages of beam commissioning. It will include details on: the beam position system and its use for realtime global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; synchrotron light diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  13. Studies on the beam system for the calibration of the OPAL jet chamber with laser beams

    International Nuclear Information System (INIS)

    Maringer, G.

    1988-07-01

    UV laser beams are an important tool for the calibration of the OPAL jet chamber. A beam transport system containing about 350 mirrors in total guides the beams from the laser outside the detector into the chamber. Four of the mirrors are moveable under remote control allowing to guide the beams into each of the 24 sectors and to correct the beam path in case of deviations. A program to control these moveable mirrors has been developed. Drift velocity measurements will be performed by means of double beams which are generated by appropriate beamsplitters. Accurate knowledge of the double beam distances is essential to obtain the desired accuracy of better than 0.1% or 10 μm. Using a CCD device with a pixel size of 23x23 μm 2 the beam distance could be measured with errors below the required limit. (orig.)

  14. Nuclear physics with radioactive beams

    International Nuclear Information System (INIS)

    Bimbot, R.

    1994-01-01

    Radioactive beams can be produced through two different and complementary ways:i. the production at rest of radioactive nuclei, followed by their acceleration using conventional techniques.This method is the best for producing low energy radioactive beams. ii. the fragmentation of high energy heavy ion beams ( over 30 MeV/u), followed by the selection and purification of a given secondary beam using magnetic spectrometers. This technique leads to high energy radioactive beams. Both methods have now been used in several laboratories in the world. Examples of the corresponding experimental equipment will be presented, and especially Lise 3, Sissi, and the spiral project at GANIL. Radioactive beams have used for several purposes in nuclear physics: i. they constitute the fastest technique ever used for transferring exotic nuclei from the production point to a well shielded place where detectors can be operated for studying their properties in good conditions. At the same time, they can be identified using solid state detectors and the time-of-flight/energy-loss technique. Illustrations of the results obtained in this domain (mass and half-life measurements, recent identification of the isotope sup 1 sup 0 sup 0 Sn) is given. ii. they are used to induce nuclear reactions which may bring new information on nuclear structure. For example, the measurement of total reaction cross-sections for many radioactive projectiles revealed the existence of halo nuclei such as sup 1 sup 1 Li and sup 1 sup 1 Be. Beams of these isotopes have been extensively used to precise their structure.iii. in the domain of nuclear astrophysics, radioactive beams are used to measure, through direct or indirect methods, the cross sections for reactions of crucial interest in nucleosynthesis. Finally, radioactive beams of light positron emitters, such as sup 1 sup 9 Ne have considerable interest for medical purposes and especially in the growing field of heavy-ion radiotherapy. 8 figs., 24 refs

  15. Beam-beam effects in the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Alexahin, Y.; Lebedev, V.; Lebrun, P.; Moore, R.S.; Sen, T.; Tollestrup, A.; Valishev, A.; Zhang, X.L.; /Fermilab

    2005-01-01

    The Tevatron in Collider Run II (2001-present) is operating with 6 times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Electromagnetic long-range and head-on interactions of high intensity proton and antiproton beams have been significant sources of beam loss and lifetime limitations. We present observations of the beam-beam phenomena in the Tevatron and results of relevant beam studies. We analyze the data and various methods employed in operations, predict the performance for planned luminosity upgrades, and discuss ways to improve it.

  16. Crystalline beams

    International Nuclear Information System (INIS)

    Schiffer, J.P.

    1989-01-01

    Ions in a storage ring are confined to a mean orbit by focusing elements. To a first approximation these may be described by a constant harmonic restoring force: F = -Kr. If the particles in the frame moving along with the beam have small random thermal energies, then they will occupy a cylindrical volume around the mean orbit and the focusing force will be balanced by that from the mutual repulsion of the particles. Inside the cylinder only residual two-particle interactions will play a significant role and some form of ordering might be expected to take place. The results of some of the first MD calculations showed a surprising result: not only were the particles arranged in the form of a tube, but they formed well-defined layers: concentric shells, with the particles in each shell arranged in a hexagonal lattice that is characteristic of two-dimensional Coulomb systems. This paper discusses the condense layer structure

  17. Intense relativistic electron beam: generation and propagation

    International Nuclear Information System (INIS)

    Mittal, K.C.; Mondal, J.

    2010-01-01

    A general review of relativistic electron beam extracted from explosive field emission diode has been presented here. The beam current in the diode gap taking into account cathode and anode plasma expansion velocity and excluding the self magnetic field effect is directly proportional to gap voltage V 3/2 and inversely proportional to the square of the effective diode gap (d-vt). In the limit of high current, self magnetic field focusing effect comes into play and results in a critical current at which pinching will take place. When the diode current exceeds the critical current, the electron flow is in the para-potential regime. Different diode geometries such as planner, coaxial, rod-pinched, reflex triode are discussed qualitatively. When the beam is injected into a vacuum drift tube the propagation of the beam is only possible in presence of a strong axial magnetic field which prevents the beam expansion in the radial direction. If the beam is injected in the drift tube filled with dense plasma, then the redistribution of the plasma electrons effectively neutralizes the beam space charge, resulting subsequent propagation of the beam along the drift tube. The beam propagation through neutral gas is similar to the plasma filled drift tube. In this case both the neutral gas pressure and the beam current regulate the transmission of the REB. (author)

  18. Beam halo in high-intensity beams

    International Nuclear Information System (INIS)

    Wangler, T.P.

    1993-01-01

    In space-charge dominated beams the nonlinear space-charge forces produce a filamentation pattern, which in projection to the 2-D phase spaces results in a 2-component beam consisting of an inner core and a diffuse outer halo. The beam-halo is of concern for a next generation of cw, high-power proton linacs that could be applied to intense neutron generators for nuclear materials processing. The author describes what has been learned about beam halo and the evolution of space-charge dominated beams using numerical simulations of initial laminar beams in uniform linear focusing channels. Initial results are presented from a study of beam entropy for an intense space-charge dominated beam

  19. Relativistic electron beams above thunderclouds

    DEFF Research Database (Denmark)

    Füellekrug, M.; Roussel-Dupre, R.; Symbalisty, E. M. D.

    2011-01-01

    of electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of similar to 7MeV to transport a total charge of similar to-10mC upwards. The impulsive current similar to 3 x 10(-3) Am-2 associated with relativistic electron beams above thunderclouds...

  20. Prevention of cardiovascular disease guided by total risk estimations - challenges and opportunities for practical implementation: highlights of a CardioVascular Clinical Trialists (CVCT) Workshop of the ESC Working Group on CardioVascular Pharmacology and Drug Therapy.

    LENUS (Irish Health Repository)

    Zannad, Faiez

    2011-11-03

    This paper presents a summary of the potential practical and economic barriers to implementation of primary prevention of cardiovascular disease guided by total cardiovascular risk estimations in the general population. It also reviews various possible solutions to overcome these barriers. The report is based on discussion among experts in the area at a special CardioVascular Clinical Trialists workshop organized by the European Society of Cardiology Working Group on Cardiovascular Pharmacology and Drug Therapy that took place in September 2009. It includes a review of the evidence in favour of the \\'treat-to-target\\' paradigm, as well as potential difficulties with this approach, including the multiple pathological processes present in high-risk patients that may not be adequately addressed by this strategy. The risk-guided therapy approach requires careful definitions of cardiovascular risk and consideration of clinical endpoints as well as the differences between trial and \\'real-world\\' populations. Cost-effectiveness presents another issue in scenarios of finite healthcare resources, as does the difficulty of documenting guideline uptake and effectiveness in the primary care setting, where early modification of risk factors may be more beneficial than later attempts to manage established disease. The key to guideline implementation is to improve the quality of risk assessment and demonstrate the association between risk factors, intervention, and reduced event rates. In the future, this may be made possible by means of automated data entry and various other measures. In conclusion, opportunities exist to increase guideline implementation in the primary care setting, with potential benefits for both the general population and healthcare resources.

  1. Self-tracking optical beam monitor

    International Nuclear Information System (INIS)

    Miyahara, T.; Mitsuhashi, T.

    1992-01-01

    A new optical beam monitor with a self-tracking system was constructed and tested at an undulator beam line of the Photon Factory. The monitor has a feedback system to receive a constant part of the radiation and gives a large range of linearity. The beam position is read out through a linear encoder to detect the self-tracking movement of a pair of photocathodes. The monitor except the feedback system is totally bakeable and UHV compatible and can be installed at a VUV or a soft x-ray beam line

  2. A synchronous beam sweeper for heavy ions

    International Nuclear Information System (INIS)

    Bogaty, J.M.

    1989-01-01

    The Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory provides a wide range of accelerated heavy ions from the periodic table. Frequently, the beam delivery rate of 12 MHz is too fast for the type of experiment on line. Reaction by-products from a target bombardment may have a decay interval much longer than the dead time between beam bunches. To prevent data from being corrupted by incoming ions a beam sweeper was developed which synchronously eliminates selected beam bunches to suit experimental needs. As the SWEEPER is broad band (DC to 6 MHz) beam delivery rates can be instantaneously changed. Ion beam bunches are selectively kicked out by an electrostatic dipole electrode pulsed to 2 kVDC. The system has been used for almost three years with several hundred hours of operating time logged to date. Beam bunch delivery rates of 6 MHz down to 25 kHz have been provided. Since this is a non-resonant system any beam delivery rate from 6 MHz down to zero can be set. In addition, burst modes have been used where beam is supplied in 12 MHz bursts and then shut down for a period of time set by the user. 3 figs

  3. Electron beam control for barely separated beams

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  4. Literature in Focus Beta Beams: Neutrino Beams

    CERN Multimedia

    2009-01-01

    By Mats Lindroos (CERN) and Mauro Mezzetto (INFN Padova, Italy) Imperial Press, 2009 The beta-beam concept for the generation of electron neutrino beams was first proposed by Piero Zucchelli in 2002. The idea created quite a stir, challenging the idea that intense neutrino beams only could be produced from the decay of pions or muons in classical neutrino beams facilities or in future neutrino factories. The concept initially struggled to make an impact but the hard work by many machine physicists, phenomenologists and theoreticians over the last five years has won the beta-beam a well-earned position as one of the frontrunners for a possible future world laboratory for high intensity neutrino oscillation physics. This is the first complete monograph on the beta-beam concept. The book describes both technical aspects and experimental aspects of the beta-beam, providing students and scientists with an insight into the possibilities o...

  5. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  6. Beam Instrumentation Global Network [BIGNET]: a common web portal for Beam instrumentalists

    CERN Document Server

    Gras, J-J

    2012-01-01

    This document will present an initiative launched during the International Particle Accelerator Conference (IPAC11) to define and produce a common web portal for Beam Instrumentation, with the aim of allowing any beam instrumentalist to easily and efficiently: - find the laboratories with machines using beams of similar characteristics (particle type, total beam intensity, bunch intensity, frequency, energy) - find the person who is working there on the beam observable concerned (i.e. beam position, loss, intensity, transverse or longitudinal profile, tune) and how to contact him/her - create discussion forums with the right audience on hot beam instrumentation topics or issues - advertise topical events and workshop - provide links towards documents describing system designs and performance assessments... This document will cover the status and prospects of the project with the aim to invite and welcome new laboratories to join the adventure.

  7. LHC Beam Instrumentation: Beam Position and Intensity Measurements (1/3)

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  8. LHC Beam Instrumentation: Beam Loss and Tune Measurements (3/3)

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  9. ISR beam scrapers

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Beam scrapers seen in the direction of the beam. The two horizontal scraper foils are near the centre of the beam pipe andthe two scrapers for protection of the vacuum chamber are further outside. In the lower part of the beam pipe is the vertical halo scraping blade.

  10. Telecommunication using muon beams

    International Nuclear Information System (INIS)

    Arnold, R.C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location

  11. Analysis of orthotropic beams

    Science.gov (United States)

    Jen Y. Liu; S. Cheng

    1979-01-01

    A plane-stress analysis of orthotropic or isotropic beams is presented. The loading conditions considered are: (1) a concentrated normal load arbitrarily located on the beam, and (2) a distributed normal load covering an arbitrary length of the beam. exhibit close agreement with existing experimental data from Sitka spruce beams. Other loading conditions can similarly...

  12. Telecommunication using muon beams

    Science.gov (United States)

    Arnold, Richard C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location.

  13. ALCBEAM - Neutral beam formation and propagation code for beam-based plasma diagnostics

    Science.gov (United States)

    Bespamyatnov, I. O.; Rowan, W. L.; Liao, K. T.

    2012-03-01

    the ion source by high voltage applied to the extraction and accelerating grids. The current distribution of a single beamlet emitted from a single pore of IOS depends on the shape of the plasma boundary in the emission region. Total beam extracted by IOS is calculated at every point of 3D mesh as sum of all contributions from each grid pore. The code effectively unifies the ion beam formation, extraction and neutralization processes with neutral beam attenuation and excitation in plasma and neutral gas and beam stopping by the beam apertures. Running time: 10 min for a standard run.

  14. Reduction of discards by technical modifications of beam trawls

    NARCIS (Netherlands)

    Marlen, van B.; Helmond, van A.T.M.; Buyvoets, E.

    2009-01-01

    Experiments were carried out in 2007 and 2008 on discard reducing techniques in flatfish beam trawling onboard FRV “Tridens” in close cooperation with the fishing industry. A total of 38 gear tests were conducted in which modified beam trawls were compared in pair with a conventional 12 m beam

  15. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  16. The CMS Beam Conditions and Radiation Monitoring System

    Science.gov (United States)

    Castro, E.; Bacchetta, N.; Bell, A. J.; Dabrowski, A.; Guthoff, M.; Hall-Wilton, R.; Hempel, M.; Henschel, H.; Lange, W.; Lohmann, W.; Müller, S.; Novgorodova, O.; Pfeiffer, D.; Ryjov, V.; Stickland, D.; Schimdt, R.; Walsh, R.

    The Compact Muon Solenoid (CMS) is one of the two large, general purpose experiments situated at the LHC at CERN. As with all high energy physics experiments, knowledge of the beam conditions and luminosity is of vital importance. The Beam Conditions and Radiation Monitoring System (BRM) is installed in CMS to protect the detector and to provide feedback to LHC on beam conditions. It is composed of several sub-systems that measure the radiation level close to or inside all sub-detectors, monitor the beam halo conditions with different time resolution, support beam tuning and protect CMS in case of adverse beam conditions by firing a beam abort signal. This paper presents three of the BRM subsystems: the Fast Beam Conditions Monitor (BCM1F), which is designed for fast flux monitoring, measuring with nanosecond time resolution, both the beam halo and collision products; the Beam Scintillator Counters (BSC), that provide hit rates and time information of beam halo and collision products; and the Beam Conditions Monitors (BCM) used as a protection system that can trigger a beam dump when beam losses occur in order to prevent damage to the pixel and tracker detectors. A description of the systems and a characterization on the basis of data collected during LHC operation is presented.

  17. LANSCE beam current limiter

    International Nuclear Information System (INIS)

    Gallegos, F.R.

    1996-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the Beam Current Limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beam line below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described

  18. A test beam upgrade based on the BEPC-LINAC

    International Nuclear Information System (INIS)

    Li Jiacai; Wu Yuanming; Cui Xiangzong; Zhang Liangsheng; Zhou Baoqing; Liu Zhengquan; Zhang Shaoping; Sun Changchun; Zhang Zhuxiang; Zhang Caidi; Zheng Linsheng; Liu Shixing; Shen Ji; Yin Zejie; Zhang Yongming; Chen Ziyu

    2004-01-01

    A total of three beam lines, E1, E2 and E3 have based on the LINAC of BEPC. The E1 beam is to be used for intense slow-positron facility. The E2 is a primary positron or electron beam with an energy of 1.3-1.5 GeV. The E3 is a secondary electron or pion test beam with a momentum can be adjustable continuously. The position accuracy of a detected particle is 0.2-0.4 mm with an event rate of 3 - 4 Hz. This beam has been successfully used for some detectors beam test. (author)

  19. STRENGTHENING OF REINFORCED CONCRETE DEEP BEAM USING FRP WRAPPING

    OpenAIRE

    Poonam.c.chavan *1, Dr C.P.Pise 2 , Prof. Y.P.Pawar2 , Prof. S.S. Kadam3

    2017-01-01

    This paper presents the results of an experimental investigation on shear strength enhancement of reinforced concrete deep beams externally reinforced with fiber reinforced polymer (FRP) composites. A total of sixteen deep beam specimens of size 150x350mm and 700mm long were cast. Eight beams of Set-I for Glass fiber reinforced polymer (GFRP) out of eight one as control beam and seven as retrofitted using Glass fiber reinforced concrete and Eight beams of Set-II one as control beam and seven ...

  20. A total market approach for condoms in Myanmar: the need for the private, public and socially marketed sectors to work together for a sustainable condom market for HIV prevention

    Science.gov (United States)

    Longfield, Kim; Mundy, Gary; Win, Zaw; Montagu, Dominic

    2015-01-01

    Background Concerns about appropriate pricing strategies and the high market share of subsidized condoms prompted Population Services International (PSI)/Myanmar to adopt a total market approach (TMA). This article presents data on the size and composition of the Myanmar condom market, identifies inefficiencies and recommends methods for better targeting public subsidy. Methodology Data on condom need and condom use came from PSI/Myanmar’s (PSI/M’s) behavioural surveys; data for key populations’ socioeconomic status profiles came from the same surveys and the National Tuberculosis Prevalence Survey. Data on market share, volumes, value and number of condoms were from PSI/M’s quarterly retail audits and Joint United Nations Programme on HIV/AIDS (UNAIDS). Results Between 2008 and 2010, the universal need for condoms decreased from 112.9 to 98.2 million while condom use increased from 32 to 46%. Free and socially marketed condoms dominated the market (94%) in 2009–11 with an increase in the proportion of free condoms over time. The retail price of socially marketed condoms was artificially low at 44 kyats ($0.05 USD) in 2011 while the price for commercial condoms was 119–399 kyats ($0.15–$0.49 USD). Equity analyses demonstrated an equal distribution of female sex workers across national wealth quintiles, but 54% of men who have sex with men and 55% of male clients were in the highest two quintiles. Donor subsidies for condoms increased over time; from $434 000 USD in 2009 to $577 000 USD in 2011. Conclusion The market for male condoms was stagnant in Myanmar due to: limited demand for condoms among key populations, the dominance of free and socially marketed condoms on the market and a neglected commercial sector. Subsidies for socially marketed and free condoms have prevented the growth of the private sector, an unintended consequence. A TMA is needed to grow and sustain the condom market in Myanmar, which requires close co-ordination between the

  1. A total market approach for condoms in Myanmar: the need for the private, public and socially marketed sectors to work together for a sustainable condom market for HIV prevention.

    Science.gov (United States)

    Htat, Han Win; Longfield, Kim; Mundy, Gary; Win, Zaw; Montagu, Dominic

    2015-03-01

    Concerns about appropriate pricing strategies and the high market share of subsidized condoms prompted Population Services International (PSI)/Myanmar to adopt a total market approach (TMA). This article presents data on the size and composition of the Myanmar condom market, identifies inefficiencies and recommends methods for better targeting public subsidy. Data on condom need and condom use came from PSI/Myanmar's (PSI/M's) behavioural surveys; data for key populations' socioeconomic status profiles came from the same surveys and the National Tuberculosis Prevalence Survey. Data on market share, volumes, value and number of condoms were from PSI/M's quarterly retail audits and Joint United Nations Programme on HIV/AIDS (UNAIDS). Between 2008 and 2010, the universal need for condoms decreased from 112.9 to 98.2 million while condom use increased from 32 to 46%. Free and socially marketed condoms dominated the market (94%) in 2009-11 with an increase in the proportion of free condoms over time. The retail price of socially marketed condoms was artificially low at 44 kyats ($0.05 USD) in 2011 while the price for commercial condoms was 119-399 kyats ($0.15-$0.49 USD). Equity analyses demonstrated an equal distribution of female sex workers across national wealth quintiles, but 54% of men who have sex with men and 55% of male clients were in the highest two quintiles. Donor subsidies for condoms increased over time; from $434,000 USD in 2009 to $577,000 USD in 2011. The market for male condoms was stagnant in Myanmar due to: limited demand for condoms among key populations, the dominance of free and socially marketed condoms on the market and a neglected commercial sector. Subsidies for socially marketed and free condoms have prevented the growth of the private sector, an unintended consequence. A TMA is needed to grow and sustain the condom market in Myanmar, which requires close co-ordination between the public, socially marketed and commercial sectors. Published

  2. The beam dump tunnels

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    In these images workers are digging the tunnels that will be used to dump the counter-circulating beams. Travelling just a fraction under the speed of light, the beams at the LHC will each carry the energy of an aircraft carrier travelling at 12 knots. In order to dispose of these beams safely, a beam dump is used to extract the beam and diffuse it before it collides with a radiation shielded graphite target.

  3. Ion beam diagnosis

    International Nuclear Information System (INIS)

    Strehl, P.

    1994-04-01

    This report is an introduction to ion beam diagnosis. After a short description of the most important ion beam parameters measurements of the beam current by means of Faraday cups, calorimetry, and beam current transformers and measurements of the beam profile by means of viewing screens, profile grids and scanning devices, and residual gas ionization monitors are described. Finally measurements in the transverse and longitudinal phase space are considered. (HSI)

  4. Nonlinear interaction of colliding beams in particle storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, J C; Month, M

    1979-01-01

    When two beams of high energy particles moving in opposite directions are brought into collision, a large amount of energy is available for the production of new particles. However to obtain a sufficiently high event rate for rare processes, such as the production of the intermediate vector boson (Z/sub 0/ and W/sup + -/), large beam currents are also required. Under this circumstance, the high charge density of one beam results in a classical electromagnetic interaction on the particles in the other beam. This very nonlinear space charge force, caled the beam-beam force, limits the total circulating charge and, thereby, the ultimate performance of the colliding ring system. The basic nature of the beam-beam force is discussed, indicating how it is quite different in the case of continuous beams, which cross each other at an angle as compared to the case of bunched beams which collide head-on. Some experimental observations on the beam-beam interaction in proton-proton and electron-positron beams are then reviewed and interpreted. An important aspect of the beam-beam problem in storage rings is to determine at what point in the analysis of the particle dynamics is it relevant to bring in the concepts of stochasticity, slow diffusion, and resonance overlap. These ideas are briefly discussed.

  5. Specialized beam diagnostic measurements for an ADTT accelerator funnel

    International Nuclear Information System (INIS)

    Gilpatrick, John Douglas

    1995-01-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for accelerator-driven transmutation technologies (ADTT) with beam-current densities greater than 5 mA/mm 2 . The primary beam-diagnostics-instrumentation requirement for these facilities is to provide sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam diagnostics instrumentation must measure beam parameters such as the projected centroids and profiles, total integrated current, and particle loss. Because of the high specific energy loss in materials at beam energies less than 20 MeV, interceptive measurements such as wire scanners or fluors cannot be used to determine beam profiles or centroids. Therefore, noninterceptive techniques must be used for on-line diagnosis of high-intensity CW beam at low energies. The beam funnel area of these proposed accelerator facilities provide a particular interesting beam measurement challenge. In this area of the accelerator, beam measurements must also sense how well the two funnel input-beams are matched to each other in phase space. This paper will discuss some of the measurement requirements for these proposed accelerator facilities and the various noninterceptive techniques to measure dual-beam funnel operation

  6. Specialized beam diagnostic measurements for an ADTT accelerator funnel

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1995-01-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for accelerator-driven transmutation technologies (ADTT) with beam-current densities greater than 5 mA/mm 2 . The primary beam-diagnostics-instrumentation requirement for these facilities is to provide sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam diagnostics instrumentation must measure beam parameters such as the projected centroids and profiles, total integrated current, and particle loss. Because of the high specific energy loss in materials at beam energies less than 20 MeV, interceptive measurements such as wire scanners or fluors cannot be used to determine beam profiles or centroids. Therefore, noninterceptive techniques must be used for on-line diagnosis of high-intensity CW beam at low energies. The beam funnel area of these proposed accelerator facilities provide a particular interesting beam measurement challenge. In this area of the accelerator, beam measurements must also sense how well the two funnel-input-beams are matched to each other in phase space. This paper will discuss some of the measurement requirements for these proposed accelerator facilities and the various noninterceptive techniques to measure dual-beam funnel operation

  7. Specialized beam diagnostic measurements for an ADTT accelerator funnel

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.

    1995-10-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for accelerator-driven transmutation technologies (ADTT) with beam-current densities greater than 5 mA/mm{sup 2}. The primary beam-diagnostics-instrumentation requirement for these facilities is to provide sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam diagnostics instrumentation must measure beam parameters such as the projected centroids and profiles, total integrated current, and particle loss. Because of the high specific energy loss in materials at beam energies less than 20 MeV, interceptive measurements such as wire scanners or fluors cannot be used to determine beam profiles or centroids. Therefore, noninterceptive techniques must be used for on-line diagnosis of high-intensity CW beam at low energies. The beam funnel area of these proposed accelerator facilities provide a particular interesting beam measurement challenge. In this area of the accelerator, beam measurements must also sense how well the two funnel-input-beams are matched to each other in phase space. This paper will discuss some of the measurement requirements for these proposed accelerator facilities and the various noninterceptive techniques to measure dual-beam funnel operation.

  8. Qualità totale e mobilità totale Total Quality and Total Mobility

    Directory of Open Access Journals (Sweden)

    Giuseppe Trieste

    2010-05-01

    Full Text Available FIABA ONLUS (Italian Fund for Elimination of Architectural Barriers was founded in 2000 with the aim of promoting a culture of equal opportunities and, above all, it has as its main goal to involve public and private institutions to create a really accessible and usable environment for everyone. Total accessibility, Total usability and Total mobility are key indicators to define quality of life within cities. A supportive environment that is free of architectural, cultural and psychological barriers allows everyone to live with ease and universality. In fact, people who access to goods and services in the urban context can use to their advantage time and space, so they can do their activities and can maintain relationships that are deemed significant for their social life. The main aim of urban accessibility is to raise the comfort of space for citizens, eliminating all barriers that discriminate people, and prevent from an equality of opportunity. “FIABA FUND - City of ... for the removal of architectural barriers” is an idea of FIABA that has already affected many regions of Italy as Lazio, Lombardy, Campania, Abruzzi and Calabria. It is a National project which provides for opening a bank account in the cities of referring, in which for the first time, all together, individuals and private and public institutions can make a donation to fund initiatives for the removal of architectural barriers within its own territory for a real and effective total accessibility. Last February the fund was launched in Rome with the aim of achieving a Capital without barriers and a Town European model of accessibility and usability. Urban mobility is a prerequisite to access to goods and services, and to organize activities related to daily life. FIABA promotes the concept of sustainable mobility for all, supported by the European Commission’s White Paper. We need a cultural change in management and organization of public means, which might focus on

  9. Beam diagnostics for low energy beams

    Directory of Open Access Journals (Sweden)

    J. Harasimowicz

    2012-12-01

    Full Text Available Low-energetic ion and antimatter beams are very attractive for a number of fundamental studies. The diagnostics of such beams, however, is a challenge due to low currents down to only a few thousands of particles per second and significant fraction of energy loss in matter at keV beam energies. A modular set of particle detectors has been developed to suit the particular beam diagnostic needs of the ultralow-energy storage ring (USR at the future facility for low-energy antiproton and ion research, accommodating very low beam intensities at energies down to 20 keV. The detectors include beam-profile monitors based on scintillating screens and secondary electron emission, sensitive Faraday cups for absolute intensity measurements, and capacitive pickups for beam position monitoring. In this paper, the design of all detectors is presented in detail and results from beam measurements are shown. The resolution limits of all detectors are described and options for further improvement summarized. Whilst initially developed for the USR, the instrumentation described in this paper is also well suited for use in other low-intensity, low-energy accelerators, storage rings, and beam lines.

  10. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  11. Beam generations of three kinds of charged particles

    International Nuclear Information System (INIS)

    Niu, K.; Mulser, P.; Drska, L.

    1991-01-01

    Analyses are given for beam generations of three kinds of charged particles: electrons, light ions, and heavy ions. The electron beam oscillates in a dense plasma irradiated by a strong laser light. When the frequency of laser light is high and its intensity ia large, the acceleration of oscillating electrons becomes large and the electrons radiate electromagnetic waves. As the reaction, the electrons feel a damping force, whose effect on oscillating electron motion is investigated first. Second, the electron beam induces the strong electromagnetic field by its self-induced electric current density when the electron number density is high. The induced electric field reduces the oscillation motion and deforms the beam. In the case of a light ion beam, the electrostatic field, induced by the beam charge, as well as the electromagnetic field, induced by the beam current, affects the beam motion. The total energy of the magnetic field surrounding the beam is rather small in comparison with its kinetic energy. In the case of heavy ion beams the beam charge at the leading edge is much smaller in comparison with the case of light ion beams when the heavy ion beam propagates in the background plasma. Thus, the induced electrostatic and electromagnetic fields do not much affect the beam propagation. (author)

  12. Beam Dynamics and Beam Losses - Circular Machines

    CERN Document Server

    Kain, V

    2016-01-01

    A basic introduction to transverse and longitudinal beam dynamics as well as the most relevant beam loss mechanisms in circular machines will be presented in this lecture. This lecture is intended for physicists and engineers with little or no knowledge of this subject.

  13. T10 Beam Studies & Beam Simulation

    CERN Document Server

    Bergmann, Michael Georges; Van Dijk, Maarten; CERN. Geneva. EN Department

    2017-01-01

    In order to test detector components before their installation in actual experiments, one uses test beams in which one can control particle typ, momentum and size to high degree. For this project the focus of a secondary beam at T10 in the East Area at CERN was analysed using an AZALEA telescope from DESY.

  14. BEAMS3D Neutral Beam Injection Model

    Energy Technology Data Exchange (ETDEWEB)

    Lazerson, Samuel

    2014-04-14

    With the advent of applied 3D fi elds in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous velocity reduction, and pitch angle scattering are modeled with the ADAS atomic physics database [1]. Benchmark calculations are presented to validate the collisionless particle orbits, neutral beam injection model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields.

  15. Successful Beam-Beam Tuneshift Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Bishofberger, Kip Aaron [Univ. of California, Los Angeles, CA (United States)

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (TEL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operations with inclusion of the TEL are presented and analyzed. It is shown that the TEL provides a way to shatter the previously inescapable beam-beam limit.

  16. Nonlinear evolution of the auroral electron beam

    Science.gov (United States)

    Maggs, James E.

    1989-01-01

    The nonlinear spatial evolution, from the source to the atmosphere, of the auroral electron beam and the beam-generated electrostatic whistler noise was studied, calculating changes in beam parameters from equations for the conservation of total particle and wave energy and momentum flux density. Wave power fluxes were calculated by numerically integrating the wave kinetic equations, and the levels of beam-generated noise were determined by using thermal levels of Cerenkov radiation as a source. It was found that beam parameters evolve on ionospheric scale lengths, and their positive slope feature in velocity space is maintained over altitudes measured in thousands of kilometers of altitude, even though they can generate wave energy density fluxes sufficient to modify the ionospheric density profile.

  17. Beam Loss in Linacs

    CERN Document Server

    Plum, M.A.

    2016-01-01

    Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful, beam loss becomes even more critical. Linacs for H- ion beams, such as the one at the Oak Ridge Spallation Neutron Source, have many more loss mechanisms compared to H+ (proton) linacs, such as the one being designed for the European Spallation Neutron Source. Interesting H- beam loss mechanisms include residual gas stripping, H+ capture and acceleration, field stripping, black-body radiation and the recently discovered intra-beam stripping mechanism. Beam halo formation, and ion source or RF turn on/off transients, are examples of beam loss mechanisms that are common for both H+ and H- accelerators. Machine protection systems play an important role in limiting the beam loss.

  18. Beam scanning system

    International Nuclear Information System (INIS)

    Enge, H.A.

    1977-01-01

    A system for deflecting a beam of particles having different momenta, preferably through a 90 0 angle, so as to cause the beam to impinge upon a moving target and to scan across the target is described. The system includes a means responsive to a beam from a suitable source for causing the beam to periodically scan in a scanning plane and further means for deflecting the periodically scanned beam through the desired angle in a deflection plane so that the deflected beam impinges on the target. Means are included in the system for reducing the momentum dispersion at the target in both the deflection and the scanning planes and for spatially focussing the beam so as to produce a desired beam diameter at the target

  19. Crossed beam experiments

    International Nuclear Information System (INIS)

    Dolder, K.T.

    1976-01-01

    Many natural phenomena can only be properly understood if one has a detailed knowledge of interactions involving atoms, molecules, ions, electrons or photons. In the laboratory these processes are often studied by preparing beams of two types of particle and observing the reactions which occur when the beams intersect. Some of the more interesting of these crossed beam experiments and their results are discussed. Proposals to extend colliding beam techniques to high energy particle physics are also outlined. (author)

  20. Clinical experience with routine diode dosimetry for electron beam radiotherapy

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Fontenla, Doracy P.; Vikram, Bhadrasain

    2000-01-01

    Purpose: Electron beam radiotherapy is frequently administered based on clinical setups without formal treatment planning. We felt, therefore, that it was important to monitor electron beam treatments by in vivo dosimetry to prevent errors in treatment delivery. In this study, we present our clinical experience with patient dose verification using electron diodes and quantitatively assess the dose perturbations caused by the diodes during electron beam radiotherapy. Methods and Materials: A commercial diode dosimeter was used for the in vivo dose measurements. During patient dosimetry, the patients were set up as usual by the therapists. Before treatment, a diode was placed on the patient's skin surface and secured with hypoallergenic tape. The patient was then treated and the diode response registered and stored in the patient radiotherapy system database via our in-house software. A customized patient in vivo dosimetry report showing patient details, expected and measured dose, and percent difference was then generated and printed for analysis and record keeping. We studied the perturbation of electron beams by diodes using film dosimetry. Beam profiles at the 90% prescription isodose depths were obtained with and without the diode on the beam central axis, for 6-20 MeV electron beams and applicator/insert sizes ranging from a 3-cm diameter circular field to a 25 x 25 cm open field. Results: In vivo dose measurements on 360 patients resulted in the following ranges of deviations from the expected dose at the various anatomic sites: Breast (222 patients) -20.3 to +23.5% (median deviation 0%); Head and Neck (63 patients) -21.5 to +14.8% (median -0.7%); Other sites (75 patients) -17.6 to +18.8% (median +0.5%). Routine diode dosimetry during the first treatment on 360 patients (460 treatment sites) resulted in 11.5% of the measurements outside our acceptable ±6% dose deviation window. Only 3.7% of the total measurements were outside ±10% dose deviation. Detailed

  1. Choking Prevention

    Science.gov (United States)

    ... Healthy Living Healthy Living Healthy Living Nutrition Fitness Sports Oral Health Emotional Wellness Growing Healthy Sleep Safety & Prevention Safety & Prevention Safety and Prevention Immunizations At Home ...

  2. Dose-homogeneity Driven Beam Delivery System Performance Requirements for MedAustron

    CERN Document Server

    Palm, M; Moser, F; Benedikt, M

    2011-01-01

    MedAustron [1], the Austrian hadron therapy center is currently under construction. Irradiation will be performed using active scanning with proton and carbon ion pencil beams. Major beam delivery system contributors to dose heterogeneities are evaluated: beam position, beam size and spot weight errors. Their individual and combined effect on the dose distribution is quantified, using semianalytical models of lateral beam spread in the nozzle and target and depth-dose curves for protons and carbon ions. Deduced requirements on critical parts of the beam delivery system are presented. Preventive and active methods to suppress the impact of beam delivery inaccuracies are proposed.

  3. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  4. Beams 92: Proceedings

    International Nuclear Information System (INIS)

    Mosher, D.; Cooperstein, G.

    1993-01-01

    This report contains papers on the following topics: Ion beam papers; electron beam, bremsstrahlung, and diagnostics papers; radiating Z- pinch papers; microwave papers; electron laser papers; advanced accelerator papers; beam and pulsed power applications papers; pulsed power papers; and these papers have been indexed separately elsewhere

  5. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI; Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Shirlane Barbosa de

    2017-07-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  6. Ion beam dump for JT-60 NBI

    International Nuclear Information System (INIS)

    Kuriyama, Masaaki; Horiike, Hiroshi; Matsuda, Shinzaburo; Morita, Hiroaki; Shibanuma, Kiyoshi

    1981-10-01

    The design of the active cooling type ion beam dump for JT-60 NBI which receives the total beam power of 5.6 MW for 10 sec continuously is described. It is composed of array of many finned tubes which is made of oxygen free copper with 0.2% silver content. The safety margin against thermal and mechanical troubles is estimated by the heat transfer and the thermal stress calculation. (author)

  7. Moving core beam energy absorber and converter

    Science.gov (United States)

    Degtiarenko, Pavel V.

    2012-12-18

    A method and apparatus for the prevention of overheating of laser or particle beam impact zones through the use of a moving-in-the-coolant-flow arrangement for the energy absorbing core of the device. Moving of the core spreads the energy deposition in it in 1, 2, or 3 dimensions, thus increasing the effective cooling area of the device.

  8. Online diagnoses of high current-density beams

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1994-01-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for production of tritium or transmutation of nuclear waste with beam-current densities greater than 5 mA/mm 2 . The primary beam-diagnostics-instrumentation requirement for these facilities is provision of sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam-diagnostics instrumentation must measure beam parameters such as the centroids and profiles, total integrated current, and particle loss. Noninterceptive techniques must be used for diagnosis of high-intensity CW beam at low energies due to the large quantity of power deposited in an interceptive diagnostic device by the beam. Transverse and longitudinal centroid measurements have been developed for bunched beams by measuring and processing image currents on the accelerator walls. Transverse beam-profile measurement-techniques have also been developed using the interaction of the particle beam with the background gases near the beam region. This paper will discuss these noninterceptive diagnostic Techniques

  9. Angular-momentum-dominated electron beams and flat-beam generation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yin-e [Univ. of Chicago, IL (United States)

    2005-06-01

    In the absence of external forces, if the dynamics within an electron beam is dominated by its angular momentum rather than other effects such as random thermal motion or self Coulomb-repulsive force (i.e., space-charge force), the beam is said to be angular-momentum-dominated. Such a beam can be directly applied to the field of electron-cooling of heavy ions; or it can be manipulated into an electron beam with large transverse emittance ratio, i.e., a flat beam. A flat beam is of interest for high-energy electron-positron colliders or accelerator-based light sources. An angular-momentum-dominated beam is generated at the Fermilab/NICADD photoinjector Laboratory (FNPL) and is accelerated to an energy of 16 MeV. The properties of such a beam is investigated systematically in experiment. The experimental results are in very good agreement with analytical expectations and simulation results. This lays a good foundation for the transformation of an angular-momentum-dominated beam into a flat beam. The round-to-flat beam transformer is composed of three skew quadrupoles. Based on a good knowledge of the angular-momentum-dominated beam, the quadrupoles are set to the proper strengths in order to apply a total torque which removes the angular momentum, resulting in a flat beam. For bunch charge around 0.5 nC, an emittance ratio of 100 ± 5 was measured, with the smaller normalized root-mean-square emittance around 0.4 mm-mrad. Effects limiting the flat-beam emittance ratio are investigated, such as the chromatic effects in the round-to-flat beam transformer, asymmetry in the initial angular-momentum-dominated beam, and space-charge effects. The most important limiting factor turns out to be the uncorrelated emittance growth caused by space charge when the beam energy is low, for example, in the rf gun area. As a result of such emittance growth prior to the round-to-flat beam transformer, the emittance ratio achievable in simulation decreases from orders of thousands to

  10. Strong-strong beam-beam simulation on parallel computer

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Ji

    2004-08-02

    The beam-beam interaction puts a strong limit on the luminosity of the high energy storage ring colliders. At the interaction points, the electromagnetic fields generated by one beam focus or defocus the opposite beam. This can cause beam blowup and a reduction of luminosity. An accurate simulation of the beam-beam interaction is needed to help optimize the luminosity in high energy colliders.

  11. Strong-strong beam-beam simulation on parallel computer

    International Nuclear Information System (INIS)

    Qiang, Ji

    2004-01-01

    The beam-beam interaction puts a strong limit on the luminosity of the high energy storage ring colliders. At the interaction points, the electromagnetic fields generated by one beam focus or defocus the opposite beam. This can cause beam blowup and a reduction of luminosity. An accurate simulation of the beam-beam interaction is needed to help optimize the luminosity in high energy colliders

  12. Evaluation of beam divergence of a negative hydrogen ion beam using Doppler shift spectroscopy diagnostics

    Science.gov (United States)

    Deka, A. J.; Bharathi, P.; Pandya, K.; Bandyopadhyay, M.; Bhuyan, M.; Yadav, R. K.; Tyagi, H.; Gahlaut, A.; Chakraborty, A.

    2018-01-01

    The Doppler Shift Spectroscopy (DSS) diagnostic is in the conceptual stage to estimate beam divergence, stripping losses, and beam uniformity of the 100 keV hydrogen Diagnostics Neutral Beam of International Thermonuclear Experimental Reactor. This DSS diagnostic is used to measure the above-mentioned parameters with an error of less than 10%. To aid the design calculations and to establish a methodology for estimation of the beam divergence, DSS measurements were carried out on the existing prototype ion source RF Operated Beam Source in India for Negative ion Research. Emissions of the fast-excited neutrals that are generated from the extracted negative ions were collected in the target tank, and the line broadening of these emissions were used for estimating beam divergence. The observed broadening is a convolution of broadenings due to beam divergence, collection optics, voltage ripple, beam focusing, and instrumental broadening. Hence, for estimating the beam divergence from the observed line broadening, a systematic line profile analysis was performed. To minimize the error in the divergence measurements, a study on error propagation in the beam divergence measurements was carried out and the error was estimated. The measurements of beam divergence were done at a constant RF power of 50 kW and a source pressure of 0.6 Pa by varying the extraction voltage from 4 kV to10 kV and the acceleration voltage from 10 kV to 15 kV. These measurements were then compared with the calorimetric divergence, and the results seemed to agree within 10%. A minimum beam divergence of ˜3° was obtained when the source was operated at an extraction voltage of ˜5 kV and at a ˜10 kV acceleration voltage, i.e., at a total applied voltage of 15 kV. This is in agreement with the values reported in experiments carried out on similar sources elsewhere.

  13. CYPRINIDS TOTAL BLOOD PROTEINS DETERMINATION

    Directory of Open Access Journals (Sweden)

    TANŢI PATRICHE

    2009-10-01

    Full Text Available In aquaculture to get a high production is conditioned by awareness and keeping of an unaltered health condition of the biological material. To be aware of the health condition of the biological material in a fish farm allows us to establish the preventive measures required to prevent spreading of a disease and the treatment to be applied in case that a mass disease occurs. The level of the total protein in serum is, first of all, a synthetically indicator of the nutritional condition of the organism, presenting, at the same time, ample qualitative and quantitative variations depending on species, age, sex, stage of sexual maturity, water temperature and especially in correlation with the health condition of fish. Modification in value of the total protein point out some metabolic perturbations in fish body.

  14. Accelerating polarized beams in Tevatron

    International Nuclear Information System (INIS)

    Teng, L.C.

    1989-02-01

    In this paper, we will examine the totality of equipment, manpower and cost necessary to obtain a polarized proton beam in the Tevatron. We will not, however, be concerned with the acquisition and acceleration of polarized /bar p/ beams. Furthermore we will consider only a planar main ring without overpass, although it is expected that Siberian snake schemes could be made to apply equally well to non-planar machines. In addition to not wanting to tackle here the task of reformulating the theory for a non-planar closed orbit, we also anticipate that as part of the Tevatron upgrade the main ring will in the not too distant future, be replaced by a planar main injector situated in a separate tunnel. 4 refs., 11 figs., 1 tab

  15. Laser beam shaping techniques

    Energy Technology Data Exchange (ETDEWEB)

    DICKEY,FRED M.; WEICHMAN,LOUIS S.; SHAGAM,RICHARD N.

    2000-03-16

    Industrial, military, medical, and research and development applications of lasers frequently require a beam with a specified irradiance distribution in some plane. A common requirement is a laser profile that is uniform over some cross-section. Such applications include laser/material processing, laser material interaction studies, fiber injection systems, optical data image processing, lithography, medical applications, and military applications. Laser beam shaping techniques can be divided into three areas: apertured beams, field mappers, and multi-aperture beam integrators. An uncertainty relation exists for laser beam shaping that puts constraints on system design. In this paper the authors review the basics of laser beam shaping and present applications and limitations of various techniques.

  16. Beam induced RF heating

    CERN Document Server

    Salvant, B; Arduini, G; Assmann, R; Baglin, V; Barnes, M J; Bartmann, W; Baudrenghien, P; Berrig, O; Bracco, C; Bravin, E; Bregliozzi, G; Bruce, R; Bertarelli, A; Carra, F; Cattenoz, G; Caspers, F; Claudet, S; Day, H; Garlasche, M; Gentini, L; Goddard, B; Grudiev, A; Henrist, B; Jones, R; Kononenko, O; Lanza, G; Lari, L; Mastoridis, T; Mertens, V; Métral, E; Mounet, N; Muller, J E; Nosych, A A; Nougaret, J L; Persichelli, S; Piguiet, A M; Redaelli, S; Roncarolo, F; Rumolo, G; Salvachua, B; Sapinski, M; Schmidt, R; Shaposhnikova, E; Tavian, L; Timmins, M; Uythoven, J; Vidal, A; Wenninger, J; Wollmann, D; Zerlauth, M

    2012-01-01

    After the 2011 run, actions were put in place during the 2011/2012 winter stop to limit beam induced radio frequency (RF) heating of LHC components. However, some components could not be changed during this short stop and continued to represent a limitation throughout 2012. In addition, the stored beam intensity increased in 2012 and the temperature of certain components became critical. In this contribution, the beam induced heating limitations for 2012 and the expected beam induced heating limitations for the restart after the Long Shutdown 1 (LS1) will be compiled. The expected consequences of running with 25 ns or 50 ns bunch spacing will be detailed, as well as the consequences of running with shorter bunch length. Finally, actions on hardware or beam parameters to monitor and mitigate the impact of beam induced heating to LHC operation after LS1 will be discussed.

  17. Craft Stick Beams

    Science.gov (United States)

    Karplus, Alan K.

    1996-01-01

    The objective of this exercise is to provide a phenomenological 'hands-on' experience that shows how geometry can affect the load carrying capacity of a material used in construction, how different materials have different failure characteristics, and how construction affects the performance of a composite material. This will be accomplished by building beams of a single material and composite beams of a mixture of materials (popsicle sticks, fiberboard sheets, and tongue depressors); testing these layered beams to determine how and where they fail; and based on the failure analysis, designing a layered beam that will fail in a predicted manner. The students will learn the effects of lamination, adhesion, and geometry in layered beam construction on beam strength and failure location.

  18. Cone-Beam Computed Tomography Evaluation of Mental Foramen Variations: A Preliminary Study

    International Nuclear Information System (INIS)

    Sheikhi, Mahnaz; Karbasi Kheir, Mitra; Hekmatian, Ehsan

    2015-01-01

    Background. Mental foramen is important in surgical operations of premolars because it transfers the mental nerves and vessels. This study evaluated the variations of mental foramen by cone-beam computed tomography among a selected Iranian population. Materials and Methods. A total number of 180 cone-beam computed tomography projections were analyzed in terms of shape, size, direction, and horizontal and vertical positions of mental foramen in the right and left sides. Results. The most common shape was oval, opening direction was posterior-superior, horizontal position was in line with second premolar, and vertical position was apical to the adjacent dental root. The mean of foremen diameter was 3.59 mm. Conclusion. In addition to the most common types of mental foramen, other variations exist, too. Hence, it reflects the significance of preoperative radiographic examinations, especially 3-dimensional images to prevent nerve damage

  19. Cone-Beam Computed Tomography Evaluation of Mental Foramen Variations: A Preliminary Study.

    Science.gov (United States)

    Sheikhi, Mahnaz; Karbasi Kheir, Mitra; Hekmatian, Ehsan

    2015-01-01

    Background. Mental foramen is important in surgical operations of premolars because it transfers the mental nerves and vessels. This study evaluated the variations of mental foramen by cone-beam computed tomography among a selected Iranian population. Materials and Methods. A total number of 180 cone-beam computed tomography projections were analyzed in terms of shape, size, direction, and horizontal and vertical positions of mental foramen in the right and left sides. Results. The most common shape was oval, opening direction was posterior-superior, horizontal position was in line with second premolar, and vertical position was apical to the adjacent dental root. The mean of foremen diameter was 3.59 mm. Conclusion. In addition to the most common types of mental foramen, other variations exist, too. Hence, it reflects the significance of preoperative radiographic examinations, especially 3-dimensional images to prevent nerve damage.

  20. Beam Extraction and Transport

    CERN Document Server

    Kalvas, T.

    2013-12-16

    This chapter gives an introduction to low-energy beam transport systems, and discusses the typically used magnetostatic elements (solenoid, dipoles and quadrupoles) and electrostatic elements (einzel lens, dipoles and quadrupoles). The ion beam emittance, beam space-charge effects and the physics of ion source extraction are introduced. Typical computer codes for analysing and designing ion optical systems are mentioned, and the trajectory tracking method most often used for extraction simulations is described in more detail.

  1. Mechanical beam isolator

    International Nuclear Information System (INIS)

    Post, R.F.; Vann, C.S.

    1996-10-01

    Back-reflections from a target, lenses, etc. can gain energy passing backwards through a laser just like the main beam gains energy passing forwards. Unless something blocks these back-reflections early in their path, they can seriously damage the laser. A Mechanical Beam Isolator is a device that blocks back-reflections early, relatively inexpensively, and without introducing aberrations to the laser beam

  2. Cyclotron radiation beam control

    International Nuclear Information System (INIS)

    Dominke, P.

    1983-01-01

    This patent application describes an apparatus for attenuating a beam of particulate radiation comprising a series of modules, each module being constituted by a sphere having a passage, a cupola covering said sphere and a base supporting said sphere, and means for causing movement of the spheres for aligning said passages with an axis of a beam line and arranging said passages out of alignment so as to attenuate the beam. (author)

  3. Chilled beam application guidebook

    CERN Document Server

    Butler, David; Gräslund, Jonas; Hogeling, Jaap; Lund Kristiansen, Erik; Reinikanen, Mika; Svensson, Gunnar

    2007-01-01

    Chilled beam systems are primarily used for cooling and ventilation in spaces, which appreciate good indoor environmental quality and individual space control. Active chilled beams are connected to the ventilation ductwork, high temperature cold water, and when desired, low temperature hot water system. Primary air supply induces room air to be recirculated through the heat exchanger of the chilled beam. In order to cool or heat the room either cold or warm water is cycled through the heat exchanger.

  4. Instability of compensated beam-beam collisions

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Autin, B.; Chen, Pisin.

    1989-01-01

    The beam-beam disruption phenomena in linear colliders are increasingly seen as a source of serious problems for these machines. A plasma compensation scheme, in which the motion of the plasma electrons in the presence of the colliding beams provides neutralizing charge and current densities, has been proposed and studied. But natural alternative to this scheme is to consider the overlapping of nearly identical high energy e + and e/sup /minus// bunches, and the collision of two such pairs - in other words, collision of two opposing relativistic positronium plasmas. It should be noticed that while the luminosity for all collisions is increased by a factor of four in this scheme, the event rate for e + e/sup /minus// collisions is only increased by a factor of two. The other factor of two corresponds to the addition of e + e + and e/sup /minus//e/sup /minus// collisions to the interaction point. This beam compensation scheme, which has been examined through computer simulation by Balakin and Solyak in the Soviet Union, promises full neutralization of beam charges and currents. These numerical investigations have shown that plasma instabilities exist in this nominally neutral system. Although the implementation of this idea seems technically daunting, the potential benefits (beamstrahlung and disruption suppression, relaxation of final focus system constraints) are such that we should consider the physics of these collisions further. In the remainder of this paper, we theoretically analyze the issues of stability and bunch parameter tolerances in this scheme. 11 refs

  5. Overview of the Beam diagnostics in the Medaustron Accelerator:Design choices and test Beam commissioning

    CERN Document Server

    Osmic, F; Gyorgy, A; Kerschbaum, A; Repovz, M; Schwarz, S; Neustadt, W; Burtin, G

    2012-01-01

    The MedAustron centre is a synchrotron based accelerator complex for cancer treatment and clinical and non-clinical research with protons and light ions, currently under construction in Wiener Neustadt, Austria. The accelerator complex is based on the CERN-PIMMS study [1] and its technical implementation by the Italian CNAO foundation in Pavia [2]. The MedAustron beam diagnostics system is based on sixteen different monitor types (153 devices in total) and will allow measuring all relevant beam parameters from the source to the irradiation rooms. The monitors will have to cope with large intensities and energy ranges. Currently, one ion source, the low energy beam transfer line and the RFQ are being commissioned in the Injector Test Stand (ITS) at CERN. This paper gives an overview of all beam monitors foreseen for the MedAustron accelerator, elaborates some of the design choices and reports the first beam commissioning results from the ITS.

  6. Dual-beam CRT

    International Nuclear Information System (INIS)

    1975-01-01

    A dual-beam cathode-ray tube having a pair of electron guns and associated deflection means disposed side-by-side on each side of a central axis is described. The electron guns are parallel and the deflection means includes beam centering plates and angled horizontal deflection plates to direct the electron beams toward the central axis, precluding the need for a large-diameter tube neck in which the entire gun structures are angled. Bowing control plates are disposed adjacent to the beam centering plates to minimize trace bowing, and an intergun shield is disposed between the horizontal deflection plates to control and correct display pattern geometry distortion

  7. GANIL beam profile detectors

    International Nuclear Information System (INIS)

    Tribouillard, C.

    1997-01-01

    In the design phase of GANIL which started in 1977, one of the priorities of the project management was equipping the beamlines with a fast and efficient system for visualizing the beam position, thus making possible adjustment of the beam transport lines optics and facilitating beam control. The implantation of some thirty detectors was foreseen in the initial design. The assembly of installed detectors (around 190) proves the advantages of these detectors for displaying all the beams extracted from GANIL: transfer and transport lines, beam extracted from SISSI, very high intensity beam, secondary ion beams from the production target of the LISE and SPEG spectrometers, different SPIRAL project lines. All of these detectors are based on standard characteristics: - standard flange diameter (DN 160) with a standard booster for all the sensors; - identical analog electronics for all the detectors, with networking; - unique display system. The new micro-channel plate non-interceptive detectors (beam profile and ion packet lengths) make possible in-line control of the beam quality and accelerator stability. (author)

  8. ALFA beam halo

    CERN Document Server

    Komarek, Tomas

    2014-01-01

    This note serves as a final report about CERN Summer Student Programme 2014 project. The beam halo is an undesired phenomenon for physics analyses on particle accelerators. It surrounds the beam core and constitutes an important part of background for signal measurements on some detectors, eg. in the forward region. In this study, the data from the ALFA detector were used, specifically from the run 191373 ($\\beta^*=90\\unit{m}$) and the run 213268 ($\\beta^*=1\\unit{km}$). Using the ROOT framework, a software for beam halo events selection was created and beam halo properties were examined. In the run 213268, excessive beam halo is suspected to be the reason for multiple beam scrapings that occurred. A kinematic reconstruction of beam halo particles is attempted in order to understand beam halo properties in the interaction point. Some further simulations are employed to find constraints for beam halo particles in order to survive in the accelerator for a longer time/many revolutions. This work represents a st...

  9. Simulation of Beam-Beam Background at CLIC

    CERN Document Server

    Sailer, Andre

    2010-01-01

    The dense beams used at CLIC to achieve a high luminosity will cause a large amount of background particles through beam-beam interactions. Generator level studies with GuineaPig and full detector simulation studies with an ILD based CLIC detector have been performed to evaluate the amount of beam-beam background hitting the vertex detector.

  10. Simulation of Beam-Beam Background at CLIC

    CERN Document Server

    Sailer, A

    2010-01-01

    The dense beams used at CLIC to achieve a high luminosity will cause a large amount of background particles through beam-beam interactions. Generator level studies with GUINEAPIG and full detector simulation studies with an ILD based CLIC detector have been performed to evaluate the amount of beam-beam back- ground hitting the vertex detector.

  11. Beam screen cryogenic control improvements for the LHC run 2

    CERN Document Server

    AUTHOR|(CDS)2068353; Rogez, Edouard; Blanco Vinuela, Enrique; Ferlin, Gerard; Tovar-Gonzalez, Antonio

    2016-01-01

    This paper presents the improvements made on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K which simultaneously ensures a good LHC beam vacuum and limits cryogenic heat loads. In total, through the 27 km of the LHC machine, there are 485 regulation loops affected by beam disturbances. Due to the increase of the LHC performance during Run 2, standard PID controllers cannot keeps the temperature transients of the beam screens within desired limits. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  12. Beam screen cryogenic control improvements for the LHC run 2

    Science.gov (United States)

    Bradu, B.; Rogez, E.; Blanco-Viñuela, E.; Ferlin, G.; Tovar-Gonzalez, A.

    2017-02-01

    This paper presents the improvements made on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K which simultaneously ensures a good LHC beam vacuum and limits cryogenic heat loads. In total, through the 27 km of the LHC machine, there are 485 regulation loops affected by beam disturbances. Due to the increase of the LHC performance during Run 2, standard PID controllers cannot keeps the temperature transients of the beam screens within desired limits. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  13. The IFUSP microtron accelerator beam transport line

    International Nuclear Information System (INIS)

    Rios, Paulo Beolchi

    2002-01-01

    In this work, the electron optical project of the IFUSP microtron beam transport line is presented, including the operational values for the parameters of the dipolar and quadrupolar electromagnets, as well as their location along the beam line. Analytical calculations and computer simulations were performed to obtain these results, and a programming tool was developed in order to analyze the beam parameters and to help studying racetrack microtrons. The electron optical simulations were split into two different study cases: the microtron booster, and the transfer line. In the first case, it was determined the main operational parameters of a microtron working far from its usual stability conditions. In the latter, it was done the basic design of the linking line between the booster and main (not yet built) microtrons, and between them and the experimental hall, with a total path length of approximately 32 m including large horizontal and vertical deflections with variable beam energy. (author)

  14. Ion beam processing of surgical materials

    Science.gov (United States)

    Williams, James M.; Buchanan, Raymond A.; Lee, In-Seop

    1989-02-01

    Ion beam processing has now achieved a secure place in surface treatment of biomaterials. This development is largely a result of the success of the process for wear prevention of orthopedic Ti-alloy in rubbing contact with ultrahigh molecular-weight polyethylene. Basic contributions of the authors in this area, together with other pertinent literature will be reviewed. Research in ion beam processing of biomaterials is turning to other areas. Among these, bioelectronics is considered to be a promising area for further effort. Pertinent experiments on effects of implantation of iridium into titanium and Ti-6Al-4V alloy on corrosion and charge injection properties are presented.

  15. Rape prevention

    Science.gov (United States)

    Date rape - prevention; Sexual assault - prevention ... Centers for Disease Control and Prevention website. Sexual assault and abuse and STDs. In: 2015 sexually transmitted diseases treatment guidelines 2015. www.cdc.gov/std/tg2015/sexual- ...

  16. Dengue Prevention

    Science.gov (United States)

    ... Address What's this? Submit What's this? Submit Button Prevention Recommend on Facebook Tweet Share Compartir This photograph ... medications to treat a dengue infection. This makes prevention the most important step, and prevention means avoiding ...

  17. Plague Prevention

    Science.gov (United States)

    ... Healthcare Professionals Clinicians Public Health Officials Veterinarians Prevention History of Plague Resources FAQ Prevention Recommend on Facebook Tweet Share Compartir Reduce rodent habitat around your ...

  18. Accelerator beam application in science and industry

    International Nuclear Information System (INIS)

    Hagiwara, M.

    1996-01-01

    Various accelerator beams are being used widely in science and industry. The area of their applications is so wide and rapidly expanding. This paper focuses on recent efforts made in the field of radiation chemistry, especially in materials development using electron and ion beams. Concerning the applications of electron beams, synthesis of SiC fibers, improvement of radiation resistance of polytetrafluoroethylene (PTFE) and preparation of an adsorbent for uranium recovery from sea water were described. In the synthesis of SiC, the electron beams were used effectively to cross-link precursor fibers to prevent their deformation upon heating for their pyrolysis to SiC fibers. The improvement of radiation resistance of PTFE was resulted successfully by its crosslinking. As to the preparation of the adsorbent for uranium recovery, chelating resins containing amidoxime groups were shown to work as a good adsorbent of uranium from sea water. The Takasaki Radiation Chemistry Research Establishment of JAERI completed the accelerator facility named TIARA for R and D of ion beam applications three years ago. Some results were presented on the studies about radiation effects on solar cells and LSIs for space use and synthesis of functional materials. Radiation resistance of solar cells was tested with both electron and proton beams using a beam scanning technique for the irradiation to a wide area, and ultra-fast transient current induced by heavy ion microbeam was measured for studies on mechanisms of single event upset (SEU) in LSIs. In the synthesis of organic functional materials, a temperature responsive particle track membrane was developed. Techniques for RBS and NRA using heavy ion beams were established for analyzing structures of multi-layered materials. Single crystalline thin film of diamond was successfully formed on Si substrate under the deposition of mass separated C-12 ions of 100 eV. (author)

  19. Clinical impact of implantable cardioverter-defibrillator in primary prevention of total mortality in non-ischaemic cardiomyopathy: results from a meta-analysis of prospective randomized clinical trials.

    Science.gov (United States)

    Romero, Jorge; Díaz, Juan Carlos; Grushko, Michael; Quispe, Renato; Briceno, David; Avendano, Ricardo; Golive, Anjani; Pina, Ileana; Natale, Andrea; Garcia, Mario J; Jorde, Ulrich P; Di Biase, Luigi

    2017-11-17

    Primary prophylactic implantable cardioverter defibrillators (ICDs) have demonstrated a clear all-cause mortality benefit in patients with ischaemic cardiomyopathy, with less compelling evidence supporting its use in patients with non-ischaemic cardiomyopathy (NICM). We performed a meta-analysis of randomized controlled trials (RCTs) evaluating the role of ICD for reduction in total mortality in NICM patients. An electronic search on PubMed, the Cochrane Library, and EMBASE databases was performed to identify the RCTs evaluating the role of prophylactic ICD placement in NICM patients. Mantel-Haenszel risk ratio (RR) fixed-effects model was used to summarize data across treatment arms. Random-effects model was used if heterogeneity (I2) ≥ 25. Patients with cardiac resynchronization therapy pacemaker (CRT-P) were included in the control group. Six RCTs, with a total of 3128 patients and a mean follow-up period of 48 ± 22 months comparing ICD with medical therapy in NICM were included in this analysis. There was a significant reduction in all-cause mortality in the ICD group compared with the medical therapy group [RR 0.79, 95% confidence interval (95% CI) 0.68-0.92; P = 0.002]. No publication bias was noted. Currently available evidence demonstrates that the use of ICD provides a clear and significant reduction in all-cause mortality among patients with NICM. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  20. Single administration of p2TA (AB103, a CD28 antagonist peptide, prevents inflammatory and thrombotic reactions and protects against gastrointestinal injury in total-body irradiated mice.

    Directory of Open Access Journals (Sweden)

    Salida Mirzoeva

    Full Text Available The goal of this study was to elucidate the action of the CD28 mimetic peptide p2TA (AB103 that attenuates an excessive inflammatory response in mitigating radiation-induced inflammatory injuries. BALB/c and A/J mice were divided into four groups: Control (C, Peptide (P; 5 mg/kg of p2TA peptide, Radiation (R; total body irradiation with 8 Gy γ-rays, and Radiation + Peptide (RP; irradiation followed by p2TA peptide 24 h later. Gastrointestinal tissue damage was evaluated by analysis of jejunum histopathology and immunohistochemistry for cell proliferation (Cyclin D1 and inflammation (COX-2 markers, as well as the presence of macrophages (F4/80. Pro-inflammatory cytokines IL-6 and KC as well as fibrinogen were quantified in plasma samples obtained from the same mice. Our results demonstrated that administration of p2TA peptide significantly reduced the irradiation-induced increase of IL-6 and fibrinogen in plasma 7 days after exposure. Seven days after total body irradiation with 8 Gy of gamma rays numbers of intestinal crypt cells were reduced and villi were shorter in irradiated animals compared to the controls. The p2TA peptide delivery 24 h after irradiation led to improved morphology of villi and crypts, increased Cyclin D1 expression, decreased COX-2 staining and decreased numbers of macrophages in small intestine of irradiated mice. Our study suggests that attenuation of CD28 signaling is a promising therapeutic approach for mitigation of radiation-induced tissue injury.

  1. CSI cardiac prevent 2015

    Directory of Open Access Journals (Sweden)

    S Ramakrishnan

    2015-01-01

    Full Text Available The CSI Cardiac Prevent 2015 was held at Hotel Taj Palace, New Delhi, on September 25-27, 2015. The major challenge was to create interest among cardiologists and physicians on preventive cardiology, a neglected area. The theme of the conference was "Innovations in Heart Disease Prevention.′′ This conference included "CSI at WHF Roadmap Workshop, Inauguration Ceremony, scientific program, plenary sessions, Nursing/Dietician track, Industry Exhibition, Social Events," Great India blood pressure Survey, and CSI Smart Heart App. A total of 848 delegates/faculties attended this conference against a total of 1140 people registered for the meeting.

  2. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  3. Atomic Ferris wheel beams

    OpenAIRE

    Lembessis, Vasileios E.

    2017-01-01

    We study the generation of atom vortex beams in the case where an atomic wave-packet, moving in free space, is diffracted from a properly tailored light mask with a spiral transverse profile. We show how such a diffraction scheme could lead to the production of an atomic Ferris wheel beam.

  4. Atomic Ferris wheel beams

    Science.gov (United States)

    Lembessis, Vasileios E.

    2017-07-01

    We study the generation of atom vortex beams in the case where a Bose-Einstein condensate, released from a trap and moving in free space, is diffracted from a properly tailored light mask with a spiral transverse profile. We show how such a diffraction scheme could lead to the production of an atomic Ferris wheel beam.

  5. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  6. Experimental study of the molecular beam destruction by beam-beam and beam-background scattering

    International Nuclear Information System (INIS)

    Bossel, U.; Dettleff, G.

    1974-01-01

    The extraction of flow properties related to the molecular motion normal to stream lines of an expanding gas jet from observed intensity profiles of supersonic beams is critically assessed. The perturbation of the profile curves by various effects is studied for a helium beam. Exponential laws appear to describe scattering effects to a satisfactory degree

  7. Electron beam transport

    International Nuclear Information System (INIS)

    Rudjak, Yu.V.; Vladyko, V.B.

    1993-01-01

    The electron beam transport in ion channel has been investigated. The influence of the external longitudinal magnetic field and self beam magnetic field on the charge neutralization process was defined. Beam head erosion under channel is curved or the availability of transverse external magnetic field was numerically simulated. The numerical investigation of the ion-hose instability was performed. The conditions, when as a result of ion-hose instability development may be coming out of the channel by beam tail, were founded. It was shown, that supplementary creation of plasma by electron beam and ions did not lead to the reduction of ion-hose instability. Sufficient slowing down of ion-hose instability development could be achieved if betatron length increased to impulse tail. In the case of a weak initial nonsymmetrical perturbation, sausage instability was investigated. Numerical simulation showed that this instability could lead to beam radius increasing in order. The electron beam guiding by low conductive plasma channel was considered. The attractive force of beam to this channel under nonsymmetrical injection was defined analytically

  8. Durnin-Whitney beams

    Science.gov (United States)

    de Jesús Cabrera-Rosas, Omar; Espíndola-Ramos, Ernesto; Alejandro Juárez-Reyes, Salvador; Julián-Macías, Israel; Ortega-Vidals, Paula; Rickenstorff-Parrao, Carolina; Silva-Ortigoza, Gilberto; Silva-Ortigoza, Ramón; Sosa-Sánchez, Citlalli Teresa

    2017-05-01

    The aim of the present work is to define a Durnin-Whitney beam as a nondiffracting beam such that its associated caustic locally only has singularities of the fold and cusp types. Since the caustic is structurally stable then the intensity pattern of this beam is also stable and this property is what makes its definition and its theoretical and experimental study worthwhile. These properties are important in applications such as uniform optical drilling in waveguides and communications through weak turbulent atmosphere. We find that in accordance with Whitney's theorem on the stability of maps from a two-dimensional manifold to a two-dimensional manifold the phase g({{Φ }}), of the complex function A({{Φ }}) characterizing the beam, locally is given by g({{Φ }})=a{{Φ }} for a fold and g({{Φ }})=b{{{Φ }}}2 for a cusp. This result implies that the Bessel beam of order zero is not stable and that any other Bessel beam is stable because locally it has a caustic of fold type. Finally, we present an example of a Durnin-Whitney beam given by g({{Φ }})=m{{Φ }}+b{{{Φ }}}2, which is a natural generalization of the Bessel beam of order m with a singularity of cusp ridge type.

  9. Dosimetry of pion beams

    International Nuclear Information System (INIS)

    Dicello, J.F.

    1975-01-01

    Negative pion beams are probably the most esoteric and most complicated type of radiation which has been suggested for use in clinical radiotherapy. Because of the limited availability of pion beams in the past, even to nuclear physicists, there exist relatively fewer basic data for this modality. Pion dosimetry is discussed

  10. Beaming teaching application

    DEFF Research Database (Denmark)

    Markovic, Milos; Madsen, Esben; Olesen, Søren Krarup

    2012-01-01

    BEAMING is a telepresence research project aiming at providing a multimodal interaction between two or more participants located at distant locations. One of the BEAMING applications allows a distant teacher to give a xylophone playing lecture to the students. Therefore, rendering of the xylophon...

  11. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Science.gov (United States)

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  12. Beam director design report

    International Nuclear Information System (INIS)

    Younger, F.C.

    1986-08-01

    A design and fabrication effort for a beam director is documented. The conceptual design provides for the beam to pass first through a bending and focusing system (or ''achromat''), through a second achromat, through an air-to-vacuum interface (the ''beam window''), and finally through the vernier steering system. Following an initial concept study for a beam director, a prototype permanent magnet 30 0 beam-bending achromat and prototype vernier steering magnet were designed and built. In volume II, copies are included of the funding instruments, requests for quotations, purchase orders, a complete set of as-built drawings, magnetic measurement reports, the concept design report, and the final report on the design and fabrication project

  13. Vortices in Gaussian beams

    CSIR Research Space (South Africa)

    Roux, FS

    2009-01-01

    Full Text Available , t0)} = P(du, dv) {FR{g(u, v, t0)}} Replacement: u→ du = t− t0 i2 ∂ ∂u′ v → dv = t− t0 i2 ∂ ∂v′ CSIR National Laser Centre – p.13/30 Differentiation i.s.o integration Evaluate the integral over the Gaussian beam (once and for all). Then, instead... . Gaussian beams with vortex dipoles CSIR National Laser Centre – p.2/30 Gaussian beam notation Gaussian beam in normalised coordinates: g(u, v, t) = exp ( −u 2 + v2 1− it ) u = xω0 v = yω0 t = zρ ρ = piω20 λ ω0 — 1/e2 beam waist radius; ρ— Rayleigh range ω ω...

  14. Bunched beam diagnostics

    International Nuclear Information System (INIS)

    Siemann, R.H.

    1989-01-01

    There is a remarkable diversity in the field of accelerator physics. Look at the proceedings of any conference. Papers range from Hamiltonian dynamics to the latest improvements of performance in accelerator X to the engineering of specialized equipment. Beam diagnostics is somewhere in the middle of this. Diagnostic instruments make the connection between theories and observations, and the capabilities of these instruments influence strongly our ability to improve performance. The gave a series of lectures in 1987 on the general topic of Principles of Beam Observation. The emphasis was on frequency domain analysis of beam generated signals in storage rings, and that is the subject of this paper. The goal is to connect spectrum analyzer observations to what the beam is doing. In addition, understanding beam spectra is essential for understanding coherent effects and instabilities in storage rings, and this is discussed extensively. 23 figures, 4 tables

  15. Atom beam source

    International Nuclear Information System (INIS)

    Franks, J.

    1984-01-01

    Ion beam V etching may give rise to undesirable effects such as uneven erosion and ion migration in dielectrics, even when the surface is neutralized by electron flooding. The effects appear due to a remaining charge imbalance on a microscopic scale, which is absent when bombarding with an uncharged beam. Saddle field sources provide a convenient means of producing energetic neutral beams of inert and reactive gases (which may be dissociated into radicals). The construction and characteristics of the sources are described and a mechanism of internal neutralization proposed. Evidence is given that uncharged beams introduce less damage than equivalent ion beams. Disruptive effects may be initiated by charge accumulation or possibly by neutralization processes which occur when ions closely approach the target surface. (author)

  16. Ion beam monitoring

    International Nuclear Information System (INIS)

    McKinney, C.R.

    1980-01-01

    An ion beam analyzer is specified, having an ion source for generating ions of a sample to be analyzed, means for extracting the sample ions, means for focusing the sample ions into a beam, separation means positioned along the ion beam for selectively deflecting species of ions, and means for detecting the selected species of ions. According to the specification, the analyzer further comprises (a) means for disabling at least a portion of the separation means, such that the ion beam from the source remains undeflected; (b) means located along the path of the undeflected ion beam for sensing the sample ions; and (c) enabling means responsive to the sensing means for automatically re-enabling the separation means when the sample ions reach a predetermined intensity level. (author)

  17. Beam director design report

    Energy Technology Data Exchange (ETDEWEB)

    Younger, F.C.

    1986-08-01

    A design and fabrication effort for a beam director is documented. The conceptual design provides for the beam to pass first through a bending and focusing system (or ''achromat''), through a second achromat, through an air-to-vacuum interface (the ''beam window''), and finally through the vernier steering system. Following an initial concept study for a beam director, a prototype permanent magnet 30/sup 0/ beam-bending achromat and prototype vernier steering magnet were designed and built. In volume II, copies are included of the funding instruments, requests for quotations, purchase orders, a complete set of as-built drawings, magnetic measurement reports, the concept design report, and the final report on the design and fabrication project. (LEW)

  18. Survey of beam-beam limitations

    International Nuclear Information System (INIS)

    Courant, E.; Cornacchia, M.; Donald, M.M.R.; Evans, L.R.; Tazzari, S.; Wilson, E.J.N.

    1979-01-01

    The effect of beam-beam interaction is known to limit the luminosity of electron-positron storage rings and will, no doubt, limit the proton-antiproton collision scheme for the SPS. While theorists are struggling to explain this phenomenon it is more instructive to list their failures than their rather limited successes, in the hope that experiments may emerge which will direct their endeavors. The search for a description of a nonlinear system as it approaches the limit in which ordered motion breaks down, is the nub of the problem. It has engaged many fine mathematical intellects for decades and will no doubt continue to do so long after ISABELLE, the p antip and LEP are past achievements. Empirical scaling laws are emerging which relate electron machines to each other but their extrapolation to proton machines remain a very speculative exercise. Experimental data on proton limits is confined to one machine, the ISR, which does not normally suffer the beam-beam effect and where it must be artificially induced or simulated. This machine is also very different in important ways from the p antip collider. The gloomy picture which has emerged recently is that the fixed limits which were conventionally assumed for proton and electron machines can only be said to be valid for the machines which engendered them - the best guess that could be made at the time. They are very difficult to extrapolate to other sets of parameters

  19. Systems analysis for modular versus multi-beam HIF drivers

    International Nuclear Information System (INIS)

    Meier, W.R.; Logan, B.G.

    2004-01-01

    Previous modeling for HIF drivers concentrated on designs in which 100 or more beams are grouped in an array and accelerated through a common set of induction cores. The total beam energy required by the target is achieved by the combination of final ion energy, current per beam and number of beams. Economic scaling favors a large number of small (∼1 cm dia.) beams. An alternative architecture has now been investigated, which we refer to as a modular driver. In this case, the driver is subdivided into many (>10) independent accelerators with one or many beams each. A key objective of the modular driver approach is to be able to demonstrate all aspects of the driver (source-to-target) by building a single, lower cost module compared to a full-scale, multi-beam driver. We consider and compare several design options for the modular driver including single-beam designs with solenoid instead of quadrupole magnets in order to transport the required current per module in a single beam, solenoid/quad combinations, and multi-beam, all-quad designs. The drivers are designed to meet the requirements of the hybrid target, which can accommodate a larger spot size than the distributed radiator target that was used for the Robust Point Design. We compare the multi-beam and modular driver configuration for a variety and assumptions and identify key technology advances needed for the modular design

  20. Beam-width spreading of vortex beams in free space

    Science.gov (United States)

    Wang, Weiwei; Li, Jinhong; Duan, Meiling

    2018-01-01

    Based on the extended Huygens-Fresnel principle and the definition of second-order moments of the Wigner distribution function, the analytical expression for the beam-width spreading of Gaussian Schell-model (GSM) vortex beams in free space are derived, and used to study the influence of beam parameters on the beam-width spreading of GSM vortex beams. With the increment of the propagation distance, the beam-width spreading of GSM vortex beams will increase; the bigger the topological charge, spatial correlation length, wavelength and waist width are, the smaller the beam-width spreading is.

  1. Artificial Neural Network Model for Low Strength RC Beam Shear ...

    African Journals Online (AJOL)

    This research was to investigate how the shear strength prediction of low strength reinforced concrete beams will improve under an ANN model. An existing database of 310 reinforced concrete beams without web reinforcement was divided into three sets of training, validation and testing. A total of 224 different architectural ...

  2. Electron Beam Lithography

    Science.gov (United States)

    Harriott, Lloyd R.

    1997-04-01

    Electron beams have played a significant role in semiconductor technology for more than twenty years. Early electron beam machines used a raster scanned beam spot to write patterns in electron-sensitive polymer resist materials. The main application of electron beam lithography has been in mask making. Despite the inherently high spatial resolution and wide process margins of electron beam lithography, the writing rate for semiconductor wafers has been too slow to be economically viable on a large scale. In the late 1970's, variable shape electron beam writing was developed, projecting a rectangular beam whose size can be varied for each "shot" exposure of a particular pattern, allowing some integrated circuits to be made economically where a variety of "customized" patterns are desired. In the cell or block projection electron beam exposure technique, a unit cell of a repetitive pattern is projected repeatedly to increase the level of parallelism. This can work well for highly repetitive patterns such as memory chips but is not well suited to complex varying patterns such as microprocessors. The rapid progress in the performance of integrated circuits has been largely driven by progress in optical lithography, through improvements in lens design and fabrication as well as the use of shorter wavelengths for the exposure radiation. Due to limitations from the opacity of lens and mask materials, it is unlikely that conventional optical printing methods can be used at wavelengths below 193 nm or feature sizes much below 180 nm. One candidate technology for a post-optical era is the Scattering with Angular Limitation Projection Electron-beam Lithography (SCALPEL) approach, which combines the high resolution and wide process latitude inherent in electron beam lithography with the throughput of a parallel projection system. A mask consisting of a low atomic number membrane and a high atomic number pattern layer is uniformly illuminated with high energy (100 ke

  3. High bandwidth beam current monitor

    International Nuclear Information System (INIS)

    Baltrusaitis, R.M.; Ekdahl, C.A.; Cooper, R.G.; Peterson, E.; Warn, C.E.

    1993-01-01

    A stripline directional coupler beam current monitor capable of measuring the time structure of a 30-ps electron beam bunch has been developed. The time response performance of the monitor compares very well with Cherenkov light produced in quartz by the electron beam. The four-pickup monitor is now used on a routine basis for measuring the beam duration, tuning for optimized beam bunching, and centering the bunch in the beam pipe

  4. Total cardiovascular disease risk assessment: a review.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2011-09-01

    The high risk strategy for the prevention of cardiovascular disease (CVD) requires an assessment of an individual\\'s total CVD risk so that the most intensive risk factor management can be directed towards those at highest risk. Here we review developments in the assessment and estimation of total CVD risk.

  5. Beam-beam limit in e+e- circular colliders

    International Nuclear Information System (INIS)

    Ohmi, K.; Tawada, M.; Kamada, S.; Oide, K.; Cai, Y.; Qiang, J.

    2004-01-01

    Beam-beam effects limit the luminosity of circular colliders. Once the bunch population exceeds a threshold, the luminosity increases at a slower rate. This phenomenon is called the beam-beam limit. Onset of the beam-beam limit has been analyzed with various simulation methods based on the weak-strong and strong-strong models. We have observed that an incoherent phenomenon is mainly concerned in the beam-beam limit. The simulation have shown that equilibrium distributions of the two colliding beams are distorted from Gaussians when the luminosity is limited. The beam-beam limit is estimated to be ξ∼0.1 for a B factory with damping time of several thousand turns

  6. 3D Terahertz Beam Profiling

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Strikwerda, Andrew; Jepsen, Peter Uhd

    2013-01-01

    We present a characterization of THz beams generated in both a two-color air plasma and in a LiNbO3 crystal. Using a commercial THz camera, we record intensity images as a function of distance through the beam waist, from which we extract 2D beam profiles and visualize our measurements into 3D beam...... profiles. For the two-color air-plasma, we measure a conical beam profile that is focused to a bell-shape at the beam waist, whereas we observe a Gaussian beam profile for the THz beam generated from the LiNbO3 crystal....

  7. Impact loads on beams on elastic foundations

    International Nuclear Information System (INIS)

    Kameswara Rao, N.S.V.; Prasad, B.B.

    1975-01-01

    Quite often, complex structural components are idealised as beams in engineering analysis and design. Also, equations governing the responses of shallow shells are mathematically equivalent to the equations governing the responses of beams on elastic foundations. Hence with possible applications in several technical disciplines, the behaviour of beams on elastic foundations subjected to impact loads is studied in detail in the present investigation both analytically and experimentally. The analytical methods include analysis and energy method. The effect of foundation parameters (stiffness, and damping constants) on the dynamic responses of the beam-foundation system has been analysed. In modal analysis, the free-vibration equation has been solved by replacing the applied impulse by suitable initial conditions and the solution has been obtained as the linear combination of an infinite sequence of discrete eigen-vectors. In the energy method, the beam-foundation system is treated to be under forced vibrations and the forcing function has been obtained using the Hertz's law of impact. In the case of free-free end conditions of the beam, the rigid body modes and the elastic modes have been superposed to obtain the total response. The responses predicted using modal analysis are higher than those obtained using energy method. From the present study it is observed that model analysis is preferable to energy method. (Auth.)

  8. First LHC beam induced tracks reconstructed in the LHCb VELO

    CERN Document Server

    Parkes, C; Bates, A; Eklund, L; Gersabeck, M; Marinho, F; Rakotomiaramanana, B; Rodrigues, E; Szumlak, T; Affolder, A; Bowcock, T; Casse, G; Donleavy, S; Hennessy, K; Huse, T; Hutchcroft, D; Mylroie-Smith, J; Noor, A; Patel, G; Rinnert, K; Smith, N A; Shears, T; Tobin, M; John, M; Bay, A; Frei, R; Haefeli, G; Keune, A; Anderson, J; McNulty, R; Traynor, S; Basiladze, S; Leflat, A; Artuso, M; Borgia, A; Lefeuvre, G; Mountain, R; Wang, J; Akiba, K; van Beuzekom, M; Jans, E; Ketel, T; Mous, I; Papadelis, A; Van Lysebetten, A; Verlaat, B; de Vries, H; Behrendt, O; Buytaert, J; de Capua, S; Collins, P; Ferro-Luzzi, M

    2009-01-01

    The Vertex Locator of the LHCb experiment has been used to fully reconstruct beam induced tracks at the LHC. A beam of protons was collided with a beam absorber during the LHC synchronisation test of the anti-clockwise beam on the weekend 22nd–24th August 2008. The resulting particles have been observed by the Vertex Locator. The LHCb Vertex Locator is a silicon micro-strip detector containing 21 planes of modules. Tracks were observed passing through up to 19 modules (38 silicon sensors). A total of over 700 tracks were reconstructed, and are being used to study the calibration and alignment of the detector.

  9. Personal extrapolation of CDF test beam use to the SSC

    International Nuclear Information System (INIS)

    Nodulman, L.

    1986-01-01

    The author's personal experience in test beam usage at CDF is used to predict SSC needs at the point of turn-on. It is concluded that the test beam demand will reflect the scale of effort involved in SSC detectors rather than the total number of them. Provision for later expansion is recommended. It is also recommended that the test beam facilities, as well as detector electronics, should reflect the available dynamic range; particularly, a single high energy beam derived from the SSC could be shared by several groups

  10. Luminescent beam stop

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Diane; Morton, Simon A.

    2017-10-25

    This disclosure provides systems, methods, and apparatus related to beam stops. In one aspect, a device comprises a luminescent material, a beam stop plate, and an optical fiber. The luminescent material is a parallelepiped having a first side and a second side that are squares and having a third side that is a rectangle or a square. The first side and the second side are perpendicular to the third side. The beam stop plate is attached to the first side of the luminescent material. The optical fiber has a first end and a second end, with the first end of the optical fiber attached to the third side of the luminescent material.

  11. WORKSHOP: Crystalline beams

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Following pioneer work by specialists at the Soviet Novosibirsk Laboratory some ten years ago, interest developed in the possibility of 'freezing' ion beams in storage rings by pushing cooling (to smooth out beam behaviour) to its limits, the final goal being to lock the ions into a neat crystal pattern. After advances by groups working on laser cooled ions in traps, and with several cooling rings now in operation, a workshop on crystalline ion beams was organized recently by the GSI (Darmstadt) Laboratory and held at Wertheim in Germany

  12. Mass spectrometer beam monitor

    International Nuclear Information System (INIS)

    McKinney, C.R.

    1980-01-01

    Improved apparatus and system were developed for determining the field desorption characteristics of a sample prior to field desorption mass spectrometry. A portion of the ion beam from the ion source is disabled so that it is undeflected in the beam analyzer. When sample ions are detected by a sensor in this portion of the beam it is then allowed to be deflected and the mass analysis occurs. Thus the source position, temperature and electric field strength can be varied until ions are produced from the sample and the field desorption characteristics can be determined. The source characteristics can be varied either automatically or manually. (DN)

  13. Is every quasar beamed?

    Science.gov (United States)

    Barthel, Peter D.

    1989-01-01

    A companion paper (Barthel et al.) reports the discovery of superluminal motion in the core of 4C 34.47, the largest known quasi-stellar radio source. Superluminal motion, the apparent continuity of small- and large-scale one-sided radio jets, and the recently established depolarization asymmetry in luminous quasars find a natural explanation in the effects of relativistic beaming. In the frameworkof of this relativistic beaming model, the available data imply that all radio-loud quasars are beamed toward the earth. Powerful radio galaxies may well form the unbeamed parent population. Radio-quiet QSOs and powerful infrared galaxies can be unified using similar orientation effects.

  14. Secondary beams at GANIL

    International Nuclear Information System (INIS)

    Doubre, H.

    1992-01-01

    GANIL, a user's facility since 1983, can deliver a broad spectrum of heavy-ion beams, from He to U, to well-equipped experimental areas. Their very large intensities are to be exploited to produce secondary beams, either using the fragmentation method (beams at energy per nucleon larger than 30 MeV/u), or the ISOL method. With the latter one, these ions have to be re-accelerated. The project of a cyclotron as a post-accelerator is described. (author) 11 refs.; 7 figs.; 3 tabs

  15. ICFA Beam Dynamics Newsletter

    Energy Technology Data Exchange (ETDEWEB)

    Pikin, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-11-21

    Electron beam ion sources technology made significant progress since 1968 when this method of producing highly charged ions in a potential trap within electron beam was proposed by E. Donets. Better understanding of physical processes in EBIS, technological advances and better simulation tools determined significant progress in key EBIS parameters: electron beam current and current density, ion trap capacity, attainable charge states. Greatly increased the scope of EBIS and EBIT applications. An attempt is made to compile some of EBIS engineering problems and solutions and to demonstrate a present stage of understanding the processes and approaches to build a better EBIS.

  16. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  17. Technique of total thyroidectomy

    International Nuclear Information System (INIS)

    Rao, R.S.

    1999-01-01

    It is essential to define the various surgical procedures that are carried out for carcinoma of the thyroid gland. They are thyroid gland, subtotal lobectomy, total thyroidectomy and near total thyroidectomy

  18. Total parenteral nutrition

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000177.htm Total parenteral nutrition To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  19. Total parenteral nutrition - infants

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007239.htm Total parenteral nutrition - infants To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  20. Neutral particle beam intensity controller

    Science.gov (United States)

    Dagenhart, W.K.

    1984-05-29

    The neutral beam intensity controller is based on selected magnetic defocusing of the ion beam prior to neutralization. The defocused portion of the beam is dumped onto a beam dump disposed perpendicular to the beam axis. Selective defocusing is accomplished by means of a magnetic field generator disposed about the neutralizer so that the field is transverse to the beam axis. The magnetic field intensity is varied to provide the selected partial beam defocusing of the ions prior to neutralization. The desired focused neutral beam portion passes along the beam path through a defining aperture in the beam dump, thereby controlling the desired fraction of neutral particles transmitted to a utilization device without altering the kinetic energy level of the desired neutral particle fraction. By proper selection of the magnetic field intensity, virtually zero through 100% intensity control of the neutral beam is achieved.

  1. Total well dominated trees

    DEFF Research Database (Denmark)

    Finbow, Arthur; Frendrup, Allan; Vestergaard, Preben D.

    cardinality then G is a total well dominated graph. In this paper we study composition and decomposition of total well dominated trees. By a reversible process we prove that any total well dominated tree can both be reduced to and constructed from a family of three small trees....

  2. Reemplazo total de cadera

    OpenAIRE

    Sánchez Vergel, Alfredo; Fundación Valle de Lili

    2002-01-01

    Definición/Tipos de prótesis/ ¿Qué pacientes se podrían beneficiar de un reemplazo total de cadera?/Artrosis de cadera/Tipos de artrosis de cadera/Alternativas al reemplazo total de cadera/Preguntas frecuentes sobre el reemplazo total de cadera.

  3. Characterizing the combinatorial beam angle selection problem

    International Nuclear Information System (INIS)

    Bangert, Mark; Ziegenhein, Peter; Oelfke, Uwe

    2012-01-01

    The beam angle selection (BAS) problem in intensity-modulated radiation therapy is often interpreted as a combinatorial optimization problem, i.e. finding the best combination of η beams in a discrete set of candidate beams. It is well established that the combinatorial BAS problem may be solved efficiently with metaheuristics such as simulated annealing or genetic algorithms. However, the underlying parameters of the optimization process, such as the inclusion of non-coplanar candidate beams, the angular resolution in the space of candidate beams, and the number of evaluated beam ensembles as well as the relative performance of different metaheuristics have not yet been systematically investigated. We study these open questions in a meta-analysis of four strategies for combinatorial optimization in order to provide a reference for future research related to the BAS problem in intensity-modulated radiation therapy treatment planning. We introduce a high-performance inverse planning engine for BAS. It performs a full fluence optimization for ≈3600 treatment plans per hour while handling up to 50 GB of dose influence data (≈1400 candidate beams). For three head and neck patients, we compare the relative performance of a genetic, a cross-entropy, a simulated annealing and a naive iterative algorithm. The selection of ensembles with 5, 7, 9 and 11 beams considering either only coplanar or all feasible candidate beams is studied for an angular resolution of 5°, 10°, 15° and 20° in the space of candidate beams. The impact of different convergence criteria is investigated in comparison to a fixed termination after the evaluation of 10 000 beam ensembles. In total, our simulations comprise a full fluence optimization for about 3000 000 treatment plans. All four combinatorial BAS strategies yield significant improvements of the objective function value and of the corresponding dose distributions compared to standard beam configurations with equi

  4. Characterizing the combinatorial beam angle selection problem

    Science.gov (United States)

    Bangert, Mark; Ziegenhein, Peter; Oelfke, Uwe

    2012-10-01

    The beam angle selection (BAS) problem in intensity-modulated radiation therapy is often interpreted as a combinatorial optimization problem, i.e. finding the best combination of η beams in a discrete set of candidate beams. It is well established that the combinatorial BAS problem may be solved efficiently with metaheuristics such as simulated annealing or genetic algorithms. However, the underlying parameters of the optimization process, such as the inclusion of non-coplanar candidate beams, the angular resolution in the space of candidate beams, and the number of evaluated beam ensembles as well as the relative performance of different metaheuristics have not yet been systematically investigated. We study these open questions in a meta-analysis of four strategies for combinatorial optimization in order to provide a reference for future research related to the BAS problem in intensity-modulated radiation therapy treatment planning. We introduce a high-performance inverse planning engine for BAS. It performs a full fluence optimization for ≈3600 treatment plans per hour while handling up to 50 GB of dose influence data (≈1400 candidate beams). For three head and neck patients, we compare the relative performance of a genetic, a cross-entropy, a simulated annealing and a naive iterative algorithm. The selection of ensembles with 5, 7, 9 and 11 beams considering either only coplanar or all feasible candidate beams is studied for an angular resolution of 5°, 10°, 15° and 20° in the space of candidate beams. The impact of different convergence criteria is investigated in comparison to a fixed termination after the evaluation of 10 000 beam ensembles. In total, our simulations comprise a full fluence optimization for about 3000 000 treatment plans. All four combinatorial BAS strategies yield significant improvements of the objective function value and of the corresponding dose distributions compared to standard beam configurations with equi

  5. Electron beam curing paint

    International Nuclear Information System (INIS)

    Maruyama, Tsutomu

    1991-04-01

    Electron beam curing (EBC) type paint is paint that is specially prepared so that it can be cured and dried by electron beam irradiation. Electron beam irradiation achieves hardly any curing and drying of ordinary normal-temperature drying type paint or heat-drying type paint. The main type of paint in which an electron beam produces a curing reaction is one in which a radical polymerization reaction takes place under irradiation. The use of this EBC painting - drying system has been considered for a variety of fields since it has a number of special features such as the fact that the paint dries instantaneously, no heat is applied and no solvent is used. (Author)

  6. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  7. Final focus test beam

    International Nuclear Information System (INIS)

    1991-03-01

    This report discusses the following: the Final Focus Test Beam Project; optical design; magnets; instrumentation; magnetic measurement and BPM calibration; mechanical alignment and stabilization; vacuum system; power supplies; control system; radiation shielding and personnel protection; infrastructure; and administration

  8. HIRENASD Beam FEM

    Data.gov (United States)

    National Aeronautics and Space Administration — This contains attempts to create BEAM FEM model. I have started a Blog to discuss this... please put your comments there and I will attempt to keep everything...

  9. Single Beam Holography.

    Science.gov (United States)

    Chen, Hsuan; Ruterbusch, Paul H.

    1979-01-01

    Discusses how holography can be used as part of undergraduate physics laboratories. The authors propose a single beam technique of holography, which will reduce the recording scheme as well as relax the isolation requirements. (HM)

  10. Iconic representation of particle beams using personal computers

    International Nuclear Information System (INIS)

    Dasgupta, S.; Sarkar, D.; Mallik, C.

    1992-01-01

    The idea of representing the character of a charged particle beam by means of its emittance ellipses, is essentially a mathematical one. For quick understanding of the beam character in a more user-friendly way, unit beam cells with particles having a uniform nature, have been pictured by suitably shaped 3-D solids. The X and Y direction momenta at particular cell areas of the particle beam combine together to give a proportionate orientation to the solid in the pseudo 3-D world of the graphic screen, creating a physical picture of the particle beam. This is expected to facilitate the comprehension of total characteristics of a beam in cases of online control of transport lines and their designs, when interfaced with various ray-tracing programs. The implementation is done in an IBM-PC environment. (author)

  11. Faraday cup dosimetry in a proton therapy beam without collimation

    International Nuclear Information System (INIS)

    Grusell, Erik; Isacsson, Ulf; Montelius, Anders; Medin, Joakim

    1995-01-01

    A Faraday cup in a proton beam can give an accurate measurement of the number of protons collected by the cup. It is shown that the collection efficiency with a proper design can be close to unity. To be able to calibrate an ionization chamber from such a measurement, as is recommended in some dosimetry protocols, the energy spectrum of the proton beam must be accurately known. This is normally not the case when the lateral beam extension is defined by collimators. Therefore a method for relating an ionization chamber measurement in an uncollimated beam to the total number of protons in the beam has been developed and is described together with experimental results from calibrating an ionization chamber using this method in the therapeutic beam in Uppsala. This method is applicable to ionization chambers of any shape and the accuracy is estimated to be 1.6% (1 SD). (Author)

  12. Electron Beam Energy Compensation by Controlling RF Pulse Shape

    CERN Document Server

    Kii, T; Kusukame, K; Masuda, K; Nakai, Y; Ohgaki, H; Yamazaki, T; Yoshikawa, K; Zen, H

    2005-01-01

    We have studied on improvement of electron beam macropulse properties from a thermionic RF gun. Though a thermionic RF gun has many salient features, there is a serious problem that back-bombardment effect worsens quality of the beam. To reduce beam energy degradation by this effect, we tried to feed non-flat RF power into the gun. As a result, we successfully obtained about 1.5 times longer macropulse and two times larger total charge per macropulse. On the other hand, we calculated transient evolution of RF power considering non-constant beam loading. The beam loading is evaluated from time evolution of cathode temperature, by use of one dimensional heat conduction model and electron trajectories' calculations by a particle simulation code. Then we found good agreement between the experimental and calculation results. Furthermore, with the same way, we studied the electron beam output dependence on the cathode radius.

  13. Strengthening Reinforced Concrete Beams with CFRP and GFRP

    Directory of Open Access Journals (Sweden)

    Mehmet Mustafa Önal

    2014-01-01

    Full Text Available Concrete beams were strengthened by wrapping the shear edges of the beams twice at 45° in opposite directions by either carbon fiber reinforced polymer (CFRP or glass fiber reinforced polymer (GFRP. The study included 3 CFRP wrapped beams, 3 GFRP wrapped beams, and 3 control beams, all of which were 150 × 250 × 2200 mm and manufactured with C20 concrete and S420a structural steel at the Gazi University Technical Education Faculty labs, Turkey. Samples in molds were cured by watering in the open air for 21 days. Four-point bending tests were made on the beam test specimens and the data were collected. Data were evaluated in terms of load displacement, bearing strength, ductility, and energy consumption. In the CFRP and GFRP reinforced beams, compared to controls, 38% and 42%, respectively, strength increase was observed. In all beams, failure-flexural stress occurred in the center as expected. Most cracking was observed in the flexural region 4. A comparison of CFRP and GFRP materials reveals that GFRP enforced parts absorb more energy. Both materials yielded successful results. Thicker epoxy application in both CFRP and GFRP beams was considered to be effective in preventing break-ups.

  14. Beam-beam diagnostics from closed-orbit distortion

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M.; Chin, Y.H.; Eden, J. [Lawrence Berkeley Lab., CA (United States); Kozanecki, W. [DAPNIA/SPP, CEN Saclay Gif-sur-Yvette, (FR)]|[Stanford Linear Accelerator Center, Menlo Park, CA (United States); Tennyson, J.; Ziemann, V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1992-07-01

    We study the applicability of beam-beam deflection techniques as a tuning tool for asymmetric B factories, focusing on PEP-II as an example. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measurements, performed at points conveniently distant from the interaction point (IP), provide distinct signatures that can be used to maintain the beams in collision and perform detailed optical diagnostics at the IP. A proposal to test this method experimentally at the TRISTAN ring is briefly discussed.

  15. SPIDER beam dump as diagnostic of the particle beam

    Energy Technology Data Exchange (ETDEWEB)

    Zaupa, M., E-mail: matteo.zaupa@igi.cnr.it; Sartori, E. [Università degli Studi di Padova, Via 8 Febbraio 2, Padova 35122 (Italy); Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy); Dalla Palma, M.; Brombin, M.; Pasqualotto, R. [Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy)

    2016-11-15

    The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.

  16. Beam-beam simulation of Möbius-modified CESR

    Science.gov (United States)

    Talman, R.; Malitsky, N.; Koyama, T.

    1997-05-01

    Colliding beam experiments at CESR with beams made round by running on the coupling resonance have been performed,(E. Young et al.), abstract, this conference and runs are planned with the beams made round by Möbius modification.(R. Talman, Phys. Rev. Lett. 74), 1590, (1995) Performance in these configurations has been simulated using TEAPOT++ tracking, map generation, stochastic, and beam-beam modules within the Unified Accelerator Libraries(N. Malitsky et al.), abstract, this conference The true CESR lattice including sextupoles and element apertures is used. Outputs from the calculation include beam profile modification, tune optimization, maximum luminosity, and (with extrapolation) beam lifetimes.

  17. Beam-beam simulations: dynamical effects and beam-beam limit for LEP3

    CERN Document Server

    Ohmi, K

    2012-01-01

    Beam-beam simulations are reported for LEP3 and TLEP-H, including a rough tune scan. The results suggest that to achieve the design luminosity in LEP3, 10% higher bunch population may be necessary, while TLEP-H can achieve the design performance without any changes. The simulations indicate that the large synchrotron tune, in conjunction with a large hourglass effect, degrades the luminosity performance. This talk was given at CERN on 4 December 2012.

  18. Betatrons with kiloampere beams

    International Nuclear Information System (INIS)

    Peterson, J.M.

    1982-11-01

    Although the magnetic-induction method of acceleration used in the betatron is inherently capable of accelerating intense particle beams to high energy, many beam-instability questions arise when beams in the kilo-ampere range are considered. The intense electromagnetic fields produced by the beam, and by the image currents and charges induced in the surrounding walls, can produce very disruptive effects. Several unstable modes of collective oscillation are possible; the suppression of any one of them usually involves energy spread for Landau damping and careful design of the electrical character of the vacuum chamber. The various design criteria are often mutually incompatible. Space-charge detuning can be severe unless large beam apertures and high-energy injection are used. In order to have an acceptably low degree of space-charge detuning in the acceleration of a 10-kilo-ampere electron beam, for example, an injection energy on the order of 50 MeV seems necessary, in which case the forces due to nearby wall images can have a larger effect than the internal forces of the beam. A method of image compensation was invented for reducing the net image forces; it serves also to decrease the longitudinal beam impedance and thus helps alleviate the longitudinal instability as well. In order to avoid the ion-electron collective instability a vacuum in the range of 10 - 8 torr is required for an acceleration time of 1 millisecond. A multi-ring betatron system using the 50-MeV Advanced Test Accelerator at LLNL as an injector was conceptually designed

  19. LHCb: Beam Pipe portrait

    CERN Multimedia

    LHCb, Collaboration

    2005-01-01

    The proton beams circulate in the accelerator in Ultra High Vacuum to make them interact only with each other when colliding at the interaction point. A special beam pipe "holds" the vacuum where they pass through the LHCb detector: it has to be mechanically very strong to stand the difference in pressure between the vacuum inside it and the air in the cavern but also be as transparent as possible for the particles originating in the proton−proton collisions.

  20. LHCb: Beam Pipe

    CERN Multimedia

    LHCb, Collaboration

    2005-01-01

    The proton beams circulate in the accelerator in Ultra High Vacuum to make them interact only with each other when colliding at the interaction point. A special beam pipe "holds" the vacuum where they pass through the LHCb detector:it has to be mechanically very strong to stand the difference in pressure between the vacuum inside it and the air in the cavern but also be as transparent as possible for the particles originating in the proton−proton collisions.

  1. PARTICLE BEAMS: Frontier course

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Driven by the quest for higher energies and optimal physics conditions, the behaviour of particle beams in accelerators and storage rings is the subject of increasing attention. Thus the second course organized jointly by the US and CERN Accelerator Schools looked towards the frontiers of particle beam knowledge. The programme held at South Padre Island, Texas, from 23-29 October attracted 125 participants including some 35 from Europe

  2. LHC First Beam 2008

    CERN Multimedia

    Tuura, L

    2008-01-01

    The CMS Centre played a major part in the LHC First Beam Event on September 10th 2008: it was a central point for CMS, hosting journalists from all over the world and providing live link-ups to collaborating institutes as well as, of course, monitoring events as they happened at Point 5. It was also a venue for celebration as the beam completed circuits of the LHC in both directions, passing successfully through the detector (Courtesy of Lassi Tuura)

  3. Terascale Beam-Beam Simulations for Tevatron, RHIC and LHC

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, J.

    2005-05-16

    In this paper, we report on recent advances in terascale simulations of the beam-beam interaction in Tevatron, RHIC and LHC.Computational methods for self consistent calculation of beam-beam forces are reviewed. New method for solving the two-dimensional Poisson equation with open boundary conditions is proposed and tested. This new spectral-finite difference method is a factor of four faster than the widely used FFT based Green function method for beam-beam interaction on axis. We also present applications to the study of antiproton losses during the injection stage at Tevatron, to the study of multiple bunch coherent beam-beam modes at RHIC, and to the study of beam-beam driven emittance growth at LHC.

  4. Terascale Beam-Beam Simulations for Tevatron, RHIC and LHC

    International Nuclear Information System (INIS)

    Qiang, J.

    2005-01-01

    In this paper, we report on recent advances in terascale simulations of the beam-beam interaction in Tevatron, RHIC and LHC.Computational methods for self consistent calculation of beam-beam forces are reviewed. New method for solving the two-dimensional Poisson equation with open boundary conditions is proposed and tested. This new spectral-finite difference method is a factor of four faster than the widely used FFT based Green function method for beam-beam interaction on axis. We also present applications to the study of antiproton losses during the injection stage at Tevatron, to the study of multiple bunch coherent beam-beam modes at RHIC, and to the study of beam-beam driven emittance growth at LHC

  5. Transverse equilibria in linear collider beam-beam collisions

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Chen, Pisin

    1991-01-01

    It has been observed in simulations of the beam-beam interaction in linear colliders that a near equilibrium pinched state of the colliding beams develops when the disruption parameter is large (D much-gt 1). In this state the beam transverse density distributions are peaked at center, with long tails. The authors present here an analytical model of the equilibrium approached by the beams, that of a generalized Bennett pinch which develops through collisionless damping due to the strong nonlinearity of the beam-beam interaction. In order to calculate the equilibrium pinched beam size, an estimation of the rms emittance growth is made which takes into account the partial adiabaticity of the collision. This pinched beam size is used to derive the luminosity enhancement factors whose scaling is in agreement with the simulation results for both D and thermal factor A = σ z /β * large, and explains the previously noted cubic relationship between round and flat beam enhancement factors

  6. Beam structure studies of low-energy ion beams

    Science.gov (United States)

    Saadatmand, K.; Schneider, J. D.; Geisik, C.; Stevens, R. R.

    1991-05-01

    The ion beam structure at various axial positions along the beam-transport line has been monitored and studied utilizing a fluor screen and a video camera. The fluor material is aluminum oxide that is plasma-jet sprayed onto the surface of an aluminum or a water-cooled copper substrate. The visual representation of the beam structure is digitized and enhanced through use of false-color coding and displayed on a TV monitor for the on-line viewing by the experimentalist. Digitized video signals are stored for further off-line processing and extracting more information about the beam, such as beam profiles. This inexpensive and effective diagnostic enables the experimentalist to observe the real-time beam response (such as evolution of the beam structure, shifts in the beam intensity at various spatial locations within the beam perimeter, and shifts in the beam center and position) to parameter changes.

  7. Torsional Strengthening of RC Beams Using GFRP Composites

    Science.gov (United States)

    Patel, Paresh V.; Jariwala, Vishnu H.; Purohit, Sharadkumar P.

    2016-09-01

    Fiber reinforced polymer as an external reinforcement is used extensively for axial, flexural and shear strengthening in structural systems. The strengthening of members subjected to torsion is recently being explored. The loading mechanism of beams located at the perimeter of buildings which carry loads from slabs, joists and beams from one side of the member generates torsion that are transferred from the beams to the columns. In this work an experimental investigation on the improvement of the torsional resistance of reinforced concrete beams using Glass Fiber Reinforced Polymer (GFRP) is presented. Total 24 RC beams have been cast in this work. Ten beams of dimension 150 mm × 150 mm × 1300 mm are subjected to pure torsion while fourteen beams of 150 mm × 150 mm × 1700 mm are subjected to combined torsion and bending. Two beams in each category are designated as control specimen and remaining beams are strengthened by GFRP wrapping of different configurations. Pure torsion on specimens is applied using specially fabricated support mechanism and universal testing machine. For applying combined torsion and bending a loading frame and test set up are fabricated. Measurements of angle of twist at regular interval of torque, torsion at first crack, and ultimate torque, are obtained for all specimens. Results of different wrapping configurations are compared for control and strengthened beams to suggest effective GFRP wrapping configuration.

  8. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  9. Polarized proton beams

    International Nuclear Information System (INIS)

    Roser, T.

    1995-01-01

    The acceleration of polarized proton beams in circular accelerators is complicated by the presence of numerous depolarizing spin resonances. Careful and tedious minimization of polarization loss at each of these resonances allowed acceleration of polarized proton beams up to 22 GeV. It has been the hope that Siberian Snakes, which are local spin rotators inserted into ring accelerators, would eliminate these resonances and allow acceleration of polarized beams with the same ease and efficiency that is now routine for unpolarized beams. First tests at IUCF with a full Siberian Snake showed that the spin dynamics with a Snake can be understood in detail. The author now has results of the first tests of a partial Siberian Snake at the AGS, accelerating polarized protons to an energy of about 25 GeV. These successful tests of storage and acceleration of polarized proton beams open up new possibilities such as stored polarized beams for internal target experiments and high energy polarized proton colliders

  10. PDX neutral-beam reionization losses

    International Nuclear Information System (INIS)

    Kugel, H.W.; Dylla, H.F.; Eubank, H.P.; Kozub, T.A.; Moore, R.; Schilling, G.; Stewart, L.D.; von Halle, A.; Williams, M.D.

    1982-02-01

    Reionization losses for 1.5 MW H 0 and 2 MW D 0 neutral beams injected into the PDX tokamak were studied using pressure gauges, photo-transistors, thermocouples, surface shielding, and surface sample analysis. Considerable outgassing of conventionally prepared 304SS ducts occurred during initial injections and gradually decreased with the cumulative absorption of beam power. Reionization power losses are presently about 5% in the ducts and about 12% total for a beamline including the duct. Present duct pressures are attributed primarily to gas from the ion source and neutralizer with much smaller contributions from residual wall desorption. Physical mechanisms for the observed duct outgassing are discussed

  11. Ion Accelerator Merges Several Beams

    Science.gov (United States)

    Aston, G.

    1984-01-01

    Intense ion beam formed by merging multiple ion beamlets into one concentrated beam. Beamlet holes in graphite screen and focusing grids arranged in hexagonal pattern. Merged beam passes through single hole in each of aluminum accelerator and decelerator grids. Ion extraction efficiency, beam intensity, and focusing improved.

  12. Preventing Addiction.

    Science.gov (United States)

    Moore, Susan Fordney

    The purpose of this paper is to provide the beginning counselor with an overview of prevention concepts. Prevention is a relatively new emphasis in community efforts to stem the rising costs of substance abuse and other high-risk behaviors. The paper discusses agent, host, and environmental prevention models and how they relate to causal theories…

  13. Beam abort detection of SSRF

    International Nuclear Information System (INIS)

    Feng Chenxia; Zhou Weimin; Leng Yongbin

    2010-01-01

    Beam abort signal is a timing signal of the SSRF (Shanghai Synchrotron Radiation Facility) storage ring. It is used to synchronize BPM processor Libera logging beam position data to identify beam abort source and improve the stability of accelerator. The concept design and engineering design of beam abort trigger module are introduced in this paper, and lab test results of this module using RF signal source also presented. Online beam test results show that this module has achieved design goal, could be used to log beam position data before beam abort. (authors)

  14. Totalization Data Exchange (TDEX)

    Data.gov (United States)

    Social Security Administration — The Totalization Data Exchange (TDEX) process is an exchange between SSA and its foreign country partners to identify deaths of beneficiaries residing abroad. The...

  15. The SPS Beam quality monitor, from design to operation

    CERN Document Server

    Papotti, G; Follin, F; Shaposhnikova, E

    2011-01-01

    The SPS Beam Quality Monitor is a system that monitors longitudinal beam parameters on a cycle-by-cycle basis and prevents extraction to the LHC in case the specifications are not met. This avoids losses, unnecessary stress of machine protection components and luminosity degradation, additionally helping efficiency during the filling process. The system has been operational since the 2009 LHC run, checking the beam pattern, its correct position with respect to the LHC references, individual bunch lengths and stability. In this paper the algorithms used, the hardware implementation and the operational aspects are presented.

  16. Beam-beam observations in the Relativistic Heavy Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Y. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Laboratory (BNL), Upton, NY (United States); White, S. [Brookhaven National Laboratory (BNL), Upton, NY (United States)

    2015-06-24

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory has been operating since 2000. Over the past decade, thanks to the continuously increased bunch intensity and reduced β*s at the interaction points, the maximum peak luminosity in the polarized proton operation has been increased by more than two orders of magnitude. In this article, we first present the beam-beam observations in the previous RHIC polarized proton runs. Then we analyze the mechanisms for the beam loss and emittance growth in the presence of beam-beam interaction. The operational challenges and limitations imposed by beam-beam interaction and their remedies are also presented. In the end, we briefly introduce head-on beam-beam compensation with electron lenses in RHIC.

  17. Total Synthesis of Avrainvilleol.

    Science.gov (United States)

    Wegener, Aaron; Miller, Kenneth A

    2017-11-03

    The first total synthesis of the marine natural product avrainvilleol is reported. The total synthesis features the first application of the transition-metal-free coupling of a tosyl hydrazone and a boronic acid to the preparation of a complex natural product, and the first example of this coupling with a hindered diortho substituted hydrazone substrate.

  18. Impact loads on beams on elastic foundations

    International Nuclear Information System (INIS)

    Kameswara Rao, N.S.V.; Prasad, B.B.

    1975-01-01

    The behavior of beams on elastic foundations subjected to impact loads is studied in detail. The effect of foundation parameters (stiffness, and damping constants) on the dynamic response of the beam-foundation system has been analyzed. In modal analysis, the free-vibration equation has been solved by replacing the applied impulse by suitable initial conditions and the solution has been obtained as the linear combination of an infinite sequence of discrete eigen-vectors. In the energy method, the beam-foundation system is treated to be under forced vibrations and the forcing function has been obtained using the Hertz's law of impact. In the case of free-free end conditions of the beam, the rigid body modes and the elastic modes have been superposed to obtain the total response. A model of an Euler-Bernoulli beam resting on Winkler foundation has been subjected to impact loads using an impact testing machine and the responses such as deflection, strain velocity and acceleration have been measured with electronic instrumentation suited for shock and vibration. The analytical and experimental results are found to be in good agreement, thus showing the applicability of modal analysis and energy method to impact problems. The effect of foundation modulus is to increase the natural frequencies of the system. However, this effect diminishes as the mode number increases. The responses such as deflection, strain and stresses in the beam increase with increasing velocities of impact. If the system is overdamped the motion is aperiodic, and if the system is underdamped the motion is oscillatory. The beam response is greatly reduced by the damping in the foundation medium. From the present study it is observed that modal analysis is preferable to energy method

  19. Beam Profile Measurement in MTA Beam Line for High Pressure RF Cavity Beam Test

    International Nuclear Information System (INIS)

    Jana, M.R.; Bross, A.; Chung, M.; Greer, S.; Johnstone, C.; Kobilarcik, T.; Koizumi, G.; Leonova, M.; Moretti, A.; Popovic, M.; Schwartz, T.

    2012-01-01

    Recent High Pressure RF (HPRF) cavity experiment at MuCool Test Area (MTA) has used 400 MeV Linac proton beam to study the beam loading effect. When the energetic proton beam passes through the cavity, it ionizes the inside gas and produces the electrons. These electrons consume RF power inside the cavity. Number of electrons produced per cm inside the cavity (at 950 psi Hydrogen gas) per incident proton is ∼ 1200. The measurement of beam position and profile are necessary. MTA is flammable gas (Hydrogen) hazard zone so we have developed a passive beam diagnostic instrument using Chromox-6 scintillation screen and CCD camera. This paper presents quantitative information about beam position and beam profile. Neutral density filter was used to avoid saturation of CCD camera. Image data is filtered and fitted with Gaussian function to compute the beam size. The beam profile obtained from scintillation screen shall be compared with multi-wire beam profile.

  20. ICFA Beam Dynamics Newsletter

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi I.; Kuczewski A.; Altinbas, Z.; Beavis, D.; Belomestnykh,; Dai, J. et al

    2012-07-01

    The Collider-Accelerator Department at Brookhaven National Laboratory is building a high-brightness 500 mA capable Energy Recovery Linac (ERL) as one of its main R&D thrusts towards eRHIC, the polarized electron - hadron collider as an upgrade of the operating RHIC facility. The ERL is in final assembly stages, with injection commisioning starting in October 2012. The objective of this ERL is to serve as a platform for R&D into high current ERL, in particular issues of halo generation and control, Higher-Order Mode (HOM) issues, coherent emissions for the beam and high-brightness, high-power beam generation and preservation. The R&D ERL features a superconducting laser-photocathode RF gun with a high quantum efficiency photoccathode served with a load-lock cathode delivery system, a highly damped 5-cell accelerating cavity, a highly flexible single-pass loop and a comprehensive system of beam instrumentation. In this ICFA Beam Dynamics Newsletter article we will describe the ERL in a degree of detail that is not usually found in regular publications. We will discuss the various systems of the ERL, following the electrons from the photocathode to the beam dump, cover the control system, machine protection etc and summarize with the status of the ERL systems.

  1. Beam Time Accounting

    CERN Document Server

    Seitova, Diana

    2016-01-01

    ISOLDE is one of the leading research facilities in the field of nuclear physics. A proton beam with an energy 1.4 GeV coming from the Proton Synchrotron Booster (PSB) hits one of the targets at ISOLDE and produces Radioactive Ion Beams (RIBs). Then, the RIBs of interest is selected and delivered to the different experimental stations. In order to deliver the beam to the certain experimental station, the positions of the devices along the beamline should satisfy certain conditions. The purpose of this project is to define the conditions for the beam to pass through the different beamlines and to store the data about device’s status for later analysis and statistics, so it would be possible to know when the beam was used for different experiments. The data with the settings of the different devices is saved in the Timber database and the first steps for making virtual devices to compile the status of the beamlines were completed.

  2. Bringing up beams

    CERN Document Server

    Katarina Anthony

    2013-01-01

    Last month, commissioning began on CERN’s newest linear accelerator: Linac4. As the replacement machine for Linac2, Linac4 will take a negative hydrogen ion beam to a staggering 160 MeV. We check in to see how the Linac4 team is preparing its machine for its new role as the first link in the accelerator chain.   The Linac4 3 MeV beam line, with the ion source in the back, the RFQ in the middle and the chopping line in the front. On 14 November, members of the Linac4 collaboration and the CERN Operations Group were brought together for their first “real day” in the Linac4 Control Room. Together, they successfully accelerated their first hydrogen ion beam to 3 MeV. It was an exciting moment for everyone involved and marked the start of one of the most critical commissioning phases for the new accelerator. At the start of the Linac4 beam line sits the CERN-made Radio Frequency Quadrupole (RFQ). This vital piece of machinery takes the beam from 45 keV to 3 MeV in ju...

  3. A better beam quality

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Progress has been made on two fronts, providing physics data and preparing for higher intensities. Over the Whitsun weekend of May 22 to 24, 5 fills for physics provided almost 30 hours of stable colliding beams, all with bunch intensities around 2x1010 protons and at a β* of 2m. The first three of these fills were with 6 bunches per beam, giving 3 pairs of collisions in all experiments. For the other two fills, the number of bunches per beam was increased to 13, giving 8 pairs of colliding bunches, and for the first time luminosities were pushed above 1029 cm-2s-1, 2 orders of magnitude higher than first collisions in March. In between and after these physics fills, nominal bunches of 1011 protons were successfully ramped and brought into collision in ATLAS and CMS for the first time (not in stable beam conditions and without squeeze). Event rates seen by the experiments were in the expected range for these conditions. In the middle of this work, a short fill with beams of 7 nominal bunches was ...

  4. Paul Collier : Balancing beams

    CERN Multimedia

    2009-01-01

    As former head of AB Operations, Paul Collier and his group were in the ‘cockpit’ for the LHC’s maiden voyage - piloting the first beam around the ring. But now, as Head of the Beams Department, he will need his feet firmly on the ground in order to balance all the beam activities at CERN. "As Department Head, I’ll have less direct contact with the machines," Collier says with a hint of regret. "I’ll still obviously be very involved, but they won’t actually let me loose in front of the keyboard anymore!" As the new Head of the BE Department, Collier will be in charge of nearly 400 people, and will oversee all the beam activities, including the preparations for the longest period of beam operation in the history of CERN. In the new organization, the BE, TE and EN Departments have been grouped together in the Accelerator and Technology Sector. "‘Partnership’ is a key word for the three departments," says Collier. "The n...

  5. Lightweight HPC beam OMEGA

    Science.gov (United States)

    Sýkora, Michal; Jedlinský, Petr; Komanec, Jan

    2017-09-01

    In the design and construction of precast bridge structures, a general goal is to achieve the maximum possible span length. Often, the weight of individual beams makes them difficult to handle, which may be a limiting factor in achieving the desired span. The design of the OMEGA beam aims to solve a part of these problems. It is a thin-walled shell made of prestressed high-performance concrete (HPC) in the shape of inverted Ω character. The concrete shell with prestressed strands is fitted with a non-stressed tendon already in the casting yard and is more easily transported and installed on the site. The shells are subsequently completed with mild steel reinforcement and cores are cast in situ together with the deck. The OMEGA beams can also be used as an alternative to steel - concrete composite bridges. Due to the higher production complexity, OMEGA beam can hardly substitute conventional prestressed beams like T or PETRA completely, but it can be a useful alternative for specific construction needs.

  6. Beam dump experiments at the AGS

    International Nuclear Information System (INIS)

    Soukas, A.; Bregman, M.; Galik, R.

    1978-01-01

    Searches for the prompt production of weak or semi-strongly interacting particles in a neutrino beam dump and their subsequent interaction or decay were performed at the AGS. The experiment is detailed using the totally active liquid scintillator detector, and mention the results of the spark chamber detector. An exposure of a copper beam dump to two orders of magnitude more protons than in previous searches at 28 GeV has yielded 104 neutrino-like events in the detector. The events from the beam dump are compared directly with those from π and K decay neutrinos produced concurrently in the normal long neutrino decay path following a 15 cm brass target. The characteristics of the events are similar. However, when compared to the rate of events predicted by scaling the 15 cm target yields, the beam dump data show an excess of 45 +- 16 events. The excess events from the beam dump appear to deposit energies greater than or equal to 1 GeV. Their source remains puzzling. Future experiments at the AGS could verify the existence of the effect, decrease the uncertainty in the predicted number of events from 30 to 10% by directly measuring the pion absorption length with a variable density target, search for threshold effects, and measure the sign of the charge of the existing muons. 22 references

  7. Beam Dynamics Challenges for FCC-ee

    CERN Document Server

    AUTHOR|(SzGeCERN)442987; Benedikt, Michael; Oide, Katsunobu; Bogomyagkov, Anton; Levichev, Evgeny; Migliorati, Mauro; Wienands, Uli

    2015-01-01

    The goals of FCC-ee include reaching luminosities of up to a few 1036 cm-2s-1 per interaction point at the Z pole or some 1034 cm-2s-1 at the ZH production peak, and pushing the beam energy up to ≥175 GeV, in a ring of 100 km circumference, with a total synchrotron-radiation power not exceeding 100 MW. A parameter baseline as well as high-luminosity crab-waist options were described in [1] and [2], respectively. The extremely high luminosity and resulting short beam lifetime (due to radiative Bhabha scattering) are sustained by top-up injection. The FCC-ee design status and typical beam parameters for different modes of operation are reported in [3]. One distinct feature of the FCC-ee design is its conception as a double ring, with separate beam pipes for the two counter-rotating (electron and positron) beams, resembling, in this aspect, the high-luminosity B factories PEP-II, KEKB and SuperKEKB as well as the LHC. The two separate rings do not only permit operation with a large number of bunches, up to a f...

  8. The diagnostic neutral beam system for text

    International Nuclear Information System (INIS)

    Hammond, D.P.; Burgin, D.; Coupland, J.R.; DeVere, A.P.C.; Green, T.S.; Klein, H.H.

    1986-01-01

    The detection of highly stripped impurity ions in a Tokamak plasma by means of charge exchange with a probing neutral beam is an interesting and developing technique. Such a beam system is being designed and manufactured by the Culham Laboratory under contract to the University of Texas at Austin. The specification is for a high brightness beam of hydrogen atoms of 30-50 keV energy with a current density of 30 mA/cm/sup 2/ in the target plane. The pulse length is 100 mS, and the beam has to be capable of being modulated at high frequency (≥ 1 KHz) to improve the overall detection capability of the diagnostic system. The total extracted current at 50 KV is 7.2A. The design has been based on a ''bucket'' type plasma source with a four-electrode extraction array of circular apertures. Low perveance extraction is used to obtain both high brightness and freedom from high voltage breakdown, in view of the high degree of reliability needed. Details of performance of the beam line measured during commissioning tests at Culham are given

  9. A beam position monitor for low current dc beams

    International Nuclear Information System (INIS)

    Adderley, P.; Barry, W.; Heefner, J.; Kloeppel, P.; Rossmanith, R.; Wise, M.; Jachim, S.

    1989-01-01

    The 4 GeV recirculating linac, CEBAF, if presently under construction and will produce a CW beam with average current between.1 and 200 μA. In order to measure beam position, the beam current will be amplitude modulated at a frequency of 10 MHz. The modulation is detected by an inductive loop type monitor with electronics sensitive only to the modulation frequency. The first test with beam from the CEBAF injector indicate that beam position can be measured with an accuracy of .1 mm at a modulated beam current of 1 μA. 1 ref., 6 figs., 1 tab

  10. Beam-beam studies for FCC-hh

    CERN Document Server

    AUTHOR|(CDS)2068329; Pieloni, Tatiana; Buffat, Xavier; Furuseth, Sondre Vik

    2017-01-01

    The Future Circular Collider hadron-hadron (FCC-hh) design study is currently exploring different IR design possibilities including round and flat optics or different crossing schemes. The present study intends to evaluate each scenario from the beam-beam effects point of view. In particular the single particle long term stability to maximize beam lifetimes and luminosity reach is used to quantify the differences. The impact of strong head on interactions on the beam quality and lifetime is addressed by means of GPU accelerated simulations code featuring a weak-strong 6-dimensional beam-beam interaction.

  11. High intensity beam dump for the Tevatron beam abort system

    International Nuclear Information System (INIS)

    Kidd, J.; Mokhov, N.; Murphy, T.; Palmer, M.; Toohig, T.; Turkot, F.; VanGinneken, A.

    1981-01-01

    The beam abort system proposed for the Fermilab Tevatron Accelerator will extract the proton beam from the ring in a single turn (approximately 20/mu/s) and direct it to an external beam dump. It is the function of the beam dump to absorb the unwanted beam and limit the escaping radiation to levels that are acceptable to the surrounding populace and apparatus. A beam dump that is expected to meet these requirements has been designed and constructed. Detailed design of the dump, including considerations leading to the choice of materials, are given. 6 refs

  12. Comparison between beam-stop and beam-hole array scatter correction techniques for industrial X-ray cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Schoerner, K., E-mail: karsten.schoerner.ext@siemens.co [Corporate Technology, Siemens AG, 81739 Muenchen (Germany); Physik-Department, Technische Universitaet Muenchen, 85748 Garching (Germany); Goldammer, M.; Stephan, J. [Corporate Technology, Siemens AG, 81739 Muenchen (Germany)

    2011-02-01

    Research highlights: {yields} We propose a scatter correction method employing a beam-hole array. {yields} Beam-hole and beam-stop array techniques are compared in respect of geometric and scattering properties. {yields} The beam-hole array method reduces overall scattering compared to a beam-stop array. {yields} Application of the beam-hole array method is successfully demonstrated for a CT of ceramic specimen. -- Abstract: In industrial X-ray cone-beam computed tomography, the inspection of large-scale samples is important because of increasing demands on their quality and long-term mechanical resilience. Large-scale samples, for example made of aluminum or iron, are strongly scattering X-rays. Scattered radiation leads to artifacts such as cupping, streaks, and a reduction in contrast in the reconstructed CT-volume. We propose a scatter correction method based on sampling primary signals by employing a beam-hole array (BHA). In this indirect method, a scatter estimate is calculated by subtraction of the sampled primary signal from the total signal, the latter taken from an image where the BHA is absent. This technique is considered complementary to the better known beam-stop array (BSA) method. The two scatter estimation methods are compared here with respect to geometric effects, scatter-to-total ratio and practicability. Scatter estimation with the BHA method yields more accurate scatter estimates in off-centered regions, and a lower scatter-to-total ratio in critical image regions where the primary signal is very low. Scatter correction with the proposed BHA method is then applied to a ceramic specimen from power generation technologies. In the reconstructed CT volume, cupping almost completely vanishes and contrast is enhanced significantly.

  13. Laparoscopic total pancreatectomy

    Science.gov (United States)

    Wang, Xin; Li, Yongbin; Cai, Yunqiang; Liu, Xubao; Peng, Bing

    2017-01-01

    Abstract Rationale: Laparoscopic total pancreatectomy is a complicated surgical procedure and rarely been reported. This study was conducted to investigate the safety and feasibility of laparoscopic total pancreatectomy. Patients and Methods: Three patients underwent laparoscopic total pancreatectomy between May 2014 and August 2015. We reviewed their general demographic data, perioperative details, and short-term outcomes. General morbidity was assessed using Clavien–Dindo classification and delayed gastric emptying (DGE) was evaluated by International Study Group of Pancreatic Surgery (ISGPS) definition. Diagnosis and Outcomes: The indications for laparoscopic total pancreatectomy were intraductal papillary mucinous neoplasm (IPMN) (n = 2) and pancreatic neuroendocrine tumor (PNET) (n = 1). All patients underwent laparoscopic pylorus and spleen-preserving total pancreatectomy, the mean operative time was 490 minutes (range 450–540 minutes), the mean estimated blood loss was 266 mL (range 100–400 minutes); 2 patients suffered from postoperative complication. All the patients recovered uneventfully with conservative treatment and discharged with a mean hospital stay 18 days (range 8–24 days). The short-term (from 108 to 600 days) follow up demonstrated 3 patients had normal and consistent glycated hemoglobin (HbA1c) level with acceptable quality of life. Lessons: Laparoscopic total pancreatectomy is feasible and safe in selected patients and pylorus and spleen preserving technique should be considered. Further prospective randomized studies are needed to obtain a comprehensive understanding the role of laparoscopic technique in total pancreatectomy. PMID:28099344

  14. Review of linear collider beam-beam interaction

    Energy Technology Data Exchange (ETDEWEB)

    Chen, P.

    1989-01-01

    Three major effects from the interaction of e/sup +/e/sup /minus// beams---disruption, beamstrahlung, and electron-positron pair creation---are reviewed. For the disruption effects we discuss the luminosity enhancement factor, the maximum and rms disruption angles, and the ''kink instability''. All the results are obtained from computer simulations. Scaling laws for the numerical results and theoretical explanations of the computer acquired phenomena are offered wherever possible. For the beamstrahlung effects we concentrate only on the final electron energy spectrum resulting from multiple photon radiation process, and the deflection angle associated with low energy particles. For the effects from electron-positron pair creation, both coherent and incoherent processes of beamstrahlung pair creation are discussed. In addition to the estimation on total number of such pairs, we also look into the energy spectrum and the deflection angle. 17 refs., 23 figs., 1 tab.

  15. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  16. Light Beam Generation

    DEFF Research Database (Denmark)

    2007-01-01

    The invention relates to a method and a system for synthesizing a set of controllable light beams by provision of a system for synthesizing a set of light beams, comprising a spatially modulated light source for generation of electromagnetic radiation with a set of replicas of a predetermined......(x-xs, y-ys), a Fourier transforming lens for Fourier transforming the electromagnetic radiation, a first spatial light modulator for phase shifting the Fourier transformed electromagnetic radiation with the phase -F(u, v) of S*, S* is the complex conjugate of the Fourier transformed symbol s, a Fourier...... transforming lens for Inverse Fourier transforming the spatially modulated radiation, whereby a set of light beams are formed propagating through the inverse Fourier plane (x', y') at desired positions (x's, y's), and a controller for controlling the position of a replica of the symbol, s, for movement...

  17. Is every quasar beamed?

    International Nuclear Information System (INIS)

    Barthel, P.D.

    1989-01-01

    A companion paper (Barthel et al.) reports the discovery of superluminal motion in the core of 4C 34.47, the largest known quasi-stellar radio source. Superluminal motion, the apparent continuity of small- and large-scale one-sided radio jets, and the recently established depolarization asymmetry in luminous quasars find a natural explanation in the effects of relativistic beaming. In the frameworkof of this relativistic beaming model, the available data imply that all radio-loud quasars are beamed toward the earth. Powerful radio galaxies may well form the unbeamed parent population. Radio-quiet QSOs and powerful infrared galaxies can be unified using similar orientation effects. 76 references

  18. Laser Beam Focus Analyser

    DEFF Research Database (Denmark)

    Nielsen, Peter Carøe; Hansen, Hans Nørgaard; Olsen, Flemming Ove

    2007-01-01

    the obtainable features in direct laser machining as well as heat affected zones in welding processes. This paper describes the development of a measuring unit capable of analysing beam shape and diameter of lasers to be used in manufacturing processes. The analyser is based on the principle of a rotating...... mechanical wire being swept through the laser beam at varying Z-heights. The reflected signal is analysed and the resulting beam profile determined. The development comprised the design of a flexible fixture capable of providing both rotation and Z-axis movement, control software including data capture...... and finally data analysis based on the ISO approach. The device was calibrated and tested on commercially available laser systems. It showed good reproducibility. It was the target to be able to measure CW lasers with a power up to 200 W, focused down to spot diameters in the range of 10µm. In order...

  19. Physics with radioactive nuclear beams

    International Nuclear Information System (INIS)

    Boyd, R.N.

    1995-01-01

    Recently developed facilities allow a wide range of new investigations of the reactions and properties of short-lived nuclei. These studies may help to solve puzzles of nuclear structure and the Big Bang. The purpose of nuclear physics is to measure properties of specific nuclides and infer from them global properties common to all nuclides, for example, is to understand nuclear sizes and matter distributions in terms of basic nuclear forces. Another is to understand the variation throughout the periodic table of the dominant quantum states, which are known as the open-quotes nuclear shell model close quotes states and are characterized, much as are atomic states, by a principal quantum number and by orbital and total angular momentum quantum numbers. In turn other nuclear phenomena, such as the collective excitations known as giant resonances, can be understood in terms of the shell-model configurations and basic nuclear parameters. Radioactive nuclear beam studies of reactions of short-lived nuclides have already yielded results with important ramifications in both nuclear physics and astrophysics. Nuclear physicists expect unstable nuclides to exhibit unusual structures or features that may test their understanding of known nuclear phenomena at extreme conditions, and perhaps even to reveal previously unknown nuclear phenomena, Astrophysicists, for their part, have known for several decades that processes in both Big Bang nucleosynthesis and stellar nucleosynthesis involve short-lived nuclides. Indeed, the original motivation for developing radioactive nuclear beams was astrophysical. (author). 25 refs., 7 figs

  20. Physics with radioactive nuclear beams

    International Nuclear Information System (INIS)

    Boyd, R.N.; Tanihata, I.

    1992-01-01

    Recently developed facilities allow a wide range of new investigations of the reactions and properties of short-lived nuclei. These studies may help to solve puzzles of nuclear structure and the Big Bang. The purpose of nuclear physics is to measure properties of specific nuclides and infer from them global properties common to all nuclides. One goal, for example, is to understand nuclear sizes and matter distributions in terms of basic nuclear forces. Another is to understand the variation throughout the periodic table of the dominant quantum states, which are known as the open-quotes nuclear shell modelclose quotes states and are characterized, much as are atomic states, by a principal quantum number and by orbital and total angular momentum quantum numbers. In turn other nuclear phenomena, such as the collective excitations known as giant resonances, can be understood in terms of the shell-model configurations and basic nuclear parameters. Radioactive nuclear beam studies of reactions of short-lived nuclides have already yielded results with important ramifications in both nuclear physics and astrophysics. Nuclear physicists expect unstable nuclides to exhibit unusual structures or features that may test their understanding of known nuclear phenomena at extreme conditions, and perhaps even to reveal previously unknown nuclear phenomena, Astrophysicists, for their part, have known for several decades that processes in both Big Bang nucleosynthesis and stellar nucleosynthesis involve short-lived nuclides. Indeed, the original motivation for developing radioactive nuclear beams was astrophysical. 25 refs., 7 figs

  1. Beam transport magnets for CEBAF

    International Nuclear Information System (INIS)

    Harwood, L.H.; Biallas, G.; Boyce, J.R.; Heilbrunn, W.; Johnson, K.; York, R.C.

    1989-01-01

    With respect to the optical system, the challenging parameters of the Continuous Electron Beam Accelerator Facility (CEBAF), a five pass recirculating electron linac, are the design goals for the emittance and energy spread of its beam. The design goals are an emittance of 2 /times/ 10/sup /minus/9/ m-rad at E 0 ≤ 0.8 kG), 390 major dipoles (/ell/ = 1, 2, and 3 m; 2 ≤ B 0 ≤ 6 kG); 707 quadrupoles (0.15, 0.30, 0.6 m; B 0 ≤ 4 kG), 96 sextupoles (/ell/ = 0.3 m, B 0 ≤ 0.2 kG), 26 septa (/ell/ = 1, 2 m; 0.3 ≤ B 0 ≤ 6 kG), and one lambertson septum (/ell/ = 1 m; B 0 ≅ 4 kG), for a total of 2267 individual magnets. Furthermore, the fact that the quadrupoles, sextupoles, and correctors are to be individually powered to provide flexibility in tuning the optics lattice leads to restrictions on their design parameters. To ensure that the required magnetic parameters are achieved, all magnets will be magnetically mapped before installation. Therefore, systems to accurately and rapidly measure the multipoles and major dipoles are required. In this paper, present planning and the results of tests performed on the system to date are outlined. 5 refs., 4 figs

  2. Design study of the SPS beam dumping system

    CERN Document Server

    Faugeras, Paul E; Schröder, G H

    1973-01-01

    An internal beam dumping system is needed for the SPS, in order to prevent uncontrolled loss of the beam in the accelerator. Several possible dumping schemes have been studied and compared in Ref. (1), and the method using fast kicker magnets has been chosen. The beam dumping system will use a pair of kicker magnets, which deflect the beam verti-cally onto the absorber blocks, and the beam will be dumped in one SPS revolution. It has been shown$^{(1)}$ that dumping a ow emittance beam of 10$^{13}$ ppp at 400 GeV/c leads to severe thermal problems in the absorber blocks. In particular, dumping the beam with fast kickers induces in the absorber blocks instantaneous temperature rises. These depend on the proton density distributions in the beam and the material used for the block and can be at least as high as l000$^{°}$C in case of aluminium. Although the values of these temperature spikes cannot be calculated with good accuracy, they are certainly higher than permitted for a reliable absorber block design. It...

  3. An Electron Beam Profile Instrument Based on FBGs

    Directory of Open Access Journals (Sweden)

    Dan Sporea

    2014-08-01

    Full Text Available Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.

  4. Optical synchrotron radiation beam imaging with a digital mask

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [Univ. of Maryland, College Park, MD (United States); Fiorito, Ralph [Univ. of Maryland, College Park, MD (United States); Corbett, Jeff [SLAC National Accelerator Lab., Menlo Park, CA (United States); Shkvarunets, Anatoly [Univ. of Maryland, College Park, MD (United States); Tian, Kai [SLAC National Accelerator Lab., Menlo Park, CA (United States); Fisher, Alan [SLAC National Accelerator Lab., Menlo Park, CA (United States); Douglas, D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wilson, F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Zhang, S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Mok, W. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Mitsuhashi, T. [KEK, Tsukuba (Japan)

    2016-01-01

    The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500mA circulating in the storage ring (equivalently 392nC). Each injection pulse contains only 40-80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during User operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by re-imaging visible synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera makes it is possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

  5. Evaluation of CP shape correction for e-beam writing

    Science.gov (United States)

    Takizawa, Masahiro; Bunya, Keita; Isobe, Hideaki; Komami, Hideaki; Abe, Kenji; Kurokawa, Masaki; Yamada, Akio; Sakamoto, Kiichi; Nakamura, Takayuki; Kuwano, Kazusumi; Tateishi, Masahiro; Chau, Larry

    2012-11-01

    Character projection (CP) exposure has some advantages compared with variable shaped beam (VSB) system; (1) shot count reduction by printing complex patterns in one e-beam shot, (2) high pattern fidelity by using CP stencil. In this paper we address another advantage of CP exposure, namely the shape correction of CP stencil for cancelling the pattern deformation on the substrate. The deformation of CP printings is decomposed into some elements. They are CP stencil manufacturing error, proximity effect, beam blur of the e-beam writer and resist blur. The element caused by beam blur of e-beam writer can be predicted by measuring the total beam blur obtained from CD-dose curves. The pattern deformation was corrected by applying the shape correction software system of D2S. The corrected CP stencil of 22nm-node standard cell was manufactured and standard cell patterns were exposed. We confirmed that our shape correction method is the appropriate solution for correcting deformation issue of CP openings. The beam blur required for the 1X nm dimensions was predicted from the exposure results of standard cell patterns with applying shape correction and CD-dose curves. We simulated the optical system to realize the required beam blur. As a result, the next electron optics has the resolving capability of 1X nm dimension.

  6. Consistency checks in beam emission modeling for neutral beam injectors

    International Nuclear Information System (INIS)

    Punyapu, Bharathi; Vattipalle, Prahlad; Sharma, Sanjeev Kumar; Baruah, Ujjwal Kumar; Crowley, Brendan

    2015-01-01

    In positive neutral beam systems, the beam parameters such as ion species fractions, power fractions and beam divergence are routinely measured using Doppler shifted beam emission spectrum. The accuracy with which these parameters are estimated depend on the accuracy of the atomic modeling involved in these estimations. In this work, an effective procedure to check the consistency of the beam emission modeling in neutral beam injectors is proposed. As a first consistency check, at a constant beam voltage and current, the intensity of the beam emission spectrum is measured by varying the pressure in the neutralizer. Then, the scaling of measured intensity of un-shifted (target) and Doppler shifted intensities (projectile) of the beam emission spectrum at these pressure values are studied. If the un-shifted component scales with pressure, then the intensity of this component will be used as a second consistency check on the beam emission modeling. As a further check, the modeled beam fractions and emission cross sections of projectile and target are used to predict the intensity of the un-shifted component and then compared with the value of measured target intensity. An agreement between the predicted and measured target intensities provide the degree of discrepancy in the beam emission modeling. In order to test this methodology, a systematic analysis of Doppler shift spectroscopy data obtained on the JET neutral beam test stand data was carried out

  7. Beam dancer fusion device

    International Nuclear Information System (INIS)

    Maier, H.B.

    1984-01-01

    To accomplish fusion of two or more fusion fuel elements numerous minute spots of energy or laser light are directed to a micro target area, there to be moved or danced about by a precision mechanical controlling apparatus at the source of the laser light or electromagnetic energy beams, so that merging and coinciding patterns of light or energy beams can occur around the area of the fuel atoms or ions. The projecting of these merging patterns may be considered as target searching techniques to locate responsive clusters of fuel elements and to compress such elements into a condition in which fusion may occur. Computerized programming may be used

  8. Diamonds for beam instrumentation

    International Nuclear Information System (INIS)

    Griesmayer, Erich

    2013-01-01

    Diamond is perhaps the most versatile, efficient and radiation tolerant material available for use in beam detectors with a correspondingly wide range of applications in beam instrumentation. Numerous practical applications have demonstrated and exploited the sensitivity of diamond to charged particles, photons and neutrons. In this paper, a brief description of a generic diamond detector is given and the interaction of the CVD diamond detector material with protons, electrons, photons and neutrons is presented. Latest results of the interaction of sCVD diamond with 14 MeV mono-energetic neutrons are shown.

  9. Euroschool on Exotic Beams

    CERN Document Server

    Pfützner, Marek; The Euroschool on Exotic Beams, vol. IV

    2014-01-01

    This is the forth volume in a series of Lecture Notes based on the highly successful Euro Summer School on Exotic Beams. The aim of these notes is to provide a thorough introduction to radioactive ion-beam physics at the level of graduate students and young postdocs starting out in the field. Each volume covers a range of topics from nuclear theory to experiment and applications. Vol I has been published as LNP 651, Vol II has been published as LNP 700, and Vol. III has been published as LNP 764.

  10. The Colliding Beams Sequencer

    International Nuclear Information System (INIS)

    Johnson, D.E.; Johnson, R.P.

    1989-01-01

    The Colliding Beam Sequencer (CBS) is a computer program used to operate the pbar-p Collider by synchronizing the applications programs and simulating the activities of the accelerator operators during filling and storage. The Sequencer acts as a meta-program, running otherwise stand alone applications programs, to do the set-up, beam transfers, acceleration, low beta turn on, and diagnostics for the transfers and storage. The Sequencer and its operational performance will be described along with its special features which include a periodic scheduler and command logger. 14 refs., 3 figs

  11. GTK beam test 2017

    CERN Document Server

    Vostinic, Snezana

    2017-01-01

    The GTK is in operation at NA62 since 2014 and is among the few silicon pixel detectors performing 4D tracking. This summer, a beam test was conducted to study the phenomena determining the detector time resolution. The project described here contributed to the beam test preparation, data taking and data analyses. One of the main goals of the test was to understand the weight field contribution to the detector time resolution. This field is distorting the signal pulse shape at the edge of the pixel. Hence, to study this effect, the position of the hits inside the pixel has to be determined. An external telescope was therefore used for this purpose.

  12. Molecular beam epitaxy

    CERN Document Server

    Pamplin, Brian R

    1980-01-01

    Molecular Beam Epitaxy introduces the reader to the use of molecular beam epitaxy (MBE) in the generation of III-V and IV-VI compounds and alloys and describes the semiconductor and integrated optics reasons for using the technique. Topics covered include semiconductor superlattices by MBE; design considerations for MBE systems; periodic doping structure in gallium arsenide (GaAs); nonstoichiometry and carrier concentration control in MBE of compound semiconductors; and MBE techniques for IV-VI optoelectronic devices. The use of MBE to fabricate integrated optical devices and to study semicond

  13. Laser and Electron Beam Processing of Semiconductors: CW Beam Processing of Ion Implanted Silicon

    Science.gov (United States)

    1980-12-31

    distribution (8) expected for the indicated As+ dose and impantation energy. The total number of electrons/cm2 calculated from this figure is 9.6 x 1014...impurity trapping centers. For typical electron-beam dwell diated surface, over the investigated range, with the mini - times of the order of I msec, we solve

  14. Total synthesis of ciguatoxin.

    Science.gov (United States)

    Hamajima, Akinari; Isobe, Minoru

    2009-01-01

    Something fishy: Ciguatoxin (see structure) is one of the principal toxins involved in ciguatera poisoning and the target of a total synthesis involving the coupling of three segments. The key transformations in this synthesis feature acetylene-dicobalthexacarbonyl complexation.

  15. Total 2004 results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  16. Total 2004 results

    International Nuclear Information System (INIS)

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  17. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty rehabilitat......The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...... rehabilitation. Since hospital stay duration has decreased considerably, the need for post-discharge physiotherapy may also have changed. Thus, the indication for and types of rehabilitation programmes need to be studied within the context of fast-track knee arthroplasty....

  18. Genoptraening efter total knaealloplastik

    DEFF Research Database (Denmark)

    Holm, Bente; Kehlet, Henrik

    2009-01-01

    The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty rehabilitat......The short- and long-term benefits of post-discharge physiotherapy regimens after total knee arthroplasty are debatable. A national survey including hospitals in Denmark that perform total knee arthroplasty showed a large variability in indication and regimen for post-knee arthroplasty...... rehabilitation. Since hospital stay duration has decreased considerably, the need for post-discharge physiotherapy may also have changed. Thus, the indication for and types of rehabilitation programmes need to be studied within the context of fast-track knee arthroplasty. Udgivelsesdato: 2009-Feb-23...

  19. Prevention: Exercise

    Medline Plus

    Full Text Available ... Steroid Injections Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen ...

  20. Prevention: Exercise

    Medline Plus

    Full Text Available ... Injections PREVENTION Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility Aerobic Exercise ...

  1. Prevention: Exercise

    Medline Plus

    Full Text Available ... Watchful Waiting and Education Injection Treatments for Spinal Pain Epidural Steroid Injections Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle Choices 10 ...

  2. Performance predictions of a focused ion beam from a laser cooled and compressed atomic beam

    Energy Technology Data Exchange (ETDEWEB)

    Haaf, G. ten; Wouters, S. H. W.; Vredenbregt, E. J. D.; Mutsaers, P. H. A. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Geer, S. B. van der [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Pulsar Physics, Burghstraat 47, 5614 BC Eindhoven (Netherlands)

    2014-12-28

    Focused ion beams are indispensable tools in the semiconductor industry because of their ability to image and modify structures at the nanometer length scale. Here, we report on performance predictions of a new type of focused ion beam based on photo-ionization of a laser cooled and compressed atomic beam. Particle tracing simulations are performed to investigate the effects of disorder-induced heating after ionization in a large electric field. They lead to a constraint on this electric field strength which is used as input for an analytical model which predicts the minimum attainable spot size as a function of, amongst others, the flux density of the atomic beam, the temperature of this beam, and the total current. At low currents (I < 10 pA), the spot size will be limited by a combination of spherical aberration and brightness, while at higher currents, this is a combination of chromatic aberration and brightness. It is expected that a nanometer size spot is possible at a current of 1 pA. The analytical model was verified with particle tracing simulations of a complete focused ion beam setup. A genetic algorithm was used to find the optimum acceleration electric field as a function of the current. At low currents, the result agrees well with the analytical model, while at higher currents, the spot sizes found are even lower due to effects that are not taken into account in the analytical model.

  3. RHIC beam loss monitor system design

    International Nuclear Information System (INIS)

    Witkover, R.; Zitvogel, E.; Michnoff, R.

    1997-01-01

    The Beam Loss Monitor (BLM) System is designed to prevent the quenching of RHIC magnets due to beam loss, provide quantitative loss data, and the loss history in the event of a beam abort. The system uses 400 ion chambers of a modified Tevatron design. To satisfy fast (single turn) and slow (100 msec) loss beam criteria and provide sensitivity for studies measurements, a range of over 8 decades is needed. An RC pre-integrator reduces the dynamic range for a low current amplifier. This is digitized for data logging. The output is also applied to an analog multiplier which compensates the energy dependence, extending the range of the abort comparators. High and low pass filters separate the signal to dual comparators with independent programmable trip levels. Up to 64 channels, on 8 VME boards, are controlled by a micro-controller based VME module, decoupling it from the front-end computer (FEC) for real-time operation. Results with the detectors in the RHIC Sextant Test and the electronics in the AGS-to-RHIC (AtR) transfer line will be presented

  4. Total lymphoid irradiation

    International Nuclear Information System (INIS)

    Sutherland, D.E.; Ferguson, R.M.; Simmons, R.L.; Kim, T.H.; Slavin, S.; Najarian, J.S.

    1983-01-01

    Total lymphoid irradiation by itself can produce sufficient immunosuppression to prolong the survival of a variety of organ allografts in experimental animals. The degree of prolongation is dose-dependent and is limited by the toxicity that occurs with higher doses. Total lymphoid irradiation is more effective before transplantation than after, but when used after transplantation can be combined with pharmacologic immunosuppression to achieve a positive effect. In some animal models, total lymphoid irradiation induces an environment in which fully allogeneic bone marrow will engraft and induce permanent chimerism in the recipients who are then tolerant to organ allografts from the donor strain. If total lymphoid irradiation is ever to have clinical applicability on a large scale, it would seem that it would have to be under circumstances in which tolerance can be induced. However, in some animal models graft-versus-host disease occurs following bone marrow transplantation, and methods to obviate its occurrence probably will be needed if this approach is to be applied clinically. In recent years, patient and graft survival rates in renal allograft recipients treated with conventional immunosuppression have improved considerably, and thus the impetus to utilize total lymphoid irradiation for its immunosuppressive effect alone is less compelling. The future of total lymphoid irradiation probably lies in devising protocols in which maintenance immunosuppression can be eliminated, or nearly eliminated, altogether. Such protocols are effective in rodents. Whether they can be applied to clinical transplantation remains to be seen

  5. Totally optimal decision rules

    KAUST Repository

    Amin, Talha

    2017-11-22

    Optimality of decision rules (patterns) can be measured in many ways. One of these is referred to as length. Length signifies the number of terms in a decision rule and is optimally minimized. Another, coverage represents the width of a rule’s applicability and generality. As such, it is desirable to maximize coverage. A totally optimal decision rule is a decision rule that has the minimum possible length and the maximum possible coverage. This paper presents a method for determining the presence of totally optimal decision rules for “complete” decision tables (representations of total functions in which different variables can have domains of differing values). Depending on the cardinalities of the domains, we can either guarantee for each tuple of values of the function that totally optimal rules exist for each row of the table (as in the case of total Boolean functions where the cardinalities are equal to 2) or, for each row, we can find a tuple of values of the function for which totally optimal rules do not exist for this row.

  6. The cooling of particle beams

    International Nuclear Information System (INIS)

    Sessler, A.M.

    1994-10-01

    A review is given of the various methods which can be employed for cooling particle beams. These methods include radiation damping, stimulated radiation damping, ionization cooling, stochastic cooling, electron cooling, laser cooling, and laser cooling with beam coupling. Laser Cooling has provided beams of the lowest temperatures, namely 1 mK, but only for ions and only for the longitudinal temperature. Recent theoretical work has suggested how laser cooling, with the coupling of beam motion, can be used to reduce the ion beam temperature in all three directions. The majority of this paper is devoted to describing laser cooling and laser cooling with beam coupling

  7. Development of total-skin electron therapy at two energies

    International Nuclear Information System (INIS)

    Cox, R.S.; Heck, R.J.; Fessenden, P.; Karzmark, C.J.; Rust, D.C.

    1990-01-01

    Total-Skin Electron Therapy (TSET) modalities have been developed at two energies on a Varian Clinac 1800. The physical criteria for the beams were determined mainly from the requirement of continuing the Stanford treatment technique, which was 12 Total-Skin Electron Therapy portals combined in six pairs. The penetration of the lower energy mode matches that previously obtained at Stanford on the Varian Clinac 10, (about 4 mm for the 80% isodose contour in the 12-field treatment). The penetration of the higher energy mode is about 8 mm at the 80% contour. The Total-Skin Electron Therapy modes necessarily use electrons produced by the two standard electron-beam modes of lowest energy, nominally 6 and 9 MeV. Measurements to verify the beam specifications were carried out with diodes, a variety of ionization chambers, and a specially constructed circular phantom for film dosimetry. Initially, the penetration of the Total-Skin Electron Therapy beams was too large to match our criteria, so two methods of reducing it were explored: (a) the energies of the electron beams produced by the machine were reduced (which also reduced the energies of the corresponding standard electron modes) and (b) a large polymethylmethacrylate degrader (2.4 m X 1.2 m) 1 cm thick was placed just in front of the patient plane. Acceptable Total-Skin Electron Therapy beams could be produced by either method and the latter was finally used. The use of the standard dose monitoring system for the Total-Skin Electron Therapy modes considerably simplifies the daily treatment delivery as well as the implementation. However, the need for reasonable dose rates at the treatment plane (3.5 meters beyond the isocenter) requires dose rates of 24 Gy/min at the isocenter. Nevertheless, it is possible to use the internal dose monitor provided the problems associated with high dose rates are addressed

  8. Investigation of the flat-beam model of the beam-beam interaction

    Directory of Open Access Journals (Sweden)

    Bjoern S. Schmekel

    2003-10-01

    Full Text Available At the interaction point of a storage ring collider each beam is subject to perturbations due to the electromagnetic field of the counterrotating beam. For flat beams, a well-known approximation models the beam by a current sheet which is uniform in the horizontal plane, restricting the particle motion to the vertical direction. In this classical model a water-bag beam distribution has been used to find working points and beam-beam tune shift parameters which lead to a stable beam distribution. We investigate the stability of a more realistic Gaussian equilibrium distribution. A linearized Vlasov equation written in action-angle variables is used to compute the radial and angular modes of a perturbation in two-dimensional phase space to first order in the displacement from the design trajectory. We find that the radial modes, which are often neglected, can have a stabilizing effect on the beam motion.

  9. Ion power balance in neutral beam heated discharges on the National Spherical Torus Experiment (NSTX)

    Science.gov (United States)

    Ross, Patrick William

    In this dissertation, ion power balance is studied in the National Spherical Torus Experiment (NSTX). In order to fully understand all the terms in the power balance equation, an experiment was conducted in which the input power of the NSTX discharges was modulated using the neutral beam input power. Individual neutral beam sources were turned on or off to increase or decrease the input power. The modulations were designed to create a localized perturbation in the fast ion phase space distribution. Measurements were taken with diagnostics on NSTX including the neutral particle analyzer (NPA), the NSTX Thomson scattering diagnostic (MPTS) and the charge exchange diagnostic (CHERS), which measure the ion and electron density and temperature. Reconstructions of the plasma equilibrium were made using the LRDFIT code and power balance was calculated using the TRANSP transport code. The TRANSP code inputs the electron and ion temperatures and densities, and calculates the various power balance terms. Excess ion heating is shown to exist for some neutral beam heated discharges on NSTX. When all three neutral beam sources are on, the total power outflow through the various loss terms exceeds the input power calculated through classical heating of the ions by the slowing down of the neutral beams. The excess heating is approximately 0.5 MW of power, which represents 8% of the total power put into the plasma from the neutral beams. This excess heating occurs at the same time as an increase in the amplitude of high frequency compressional Alfven eigenmodes (CAEs) with frequencies of 0.5--1.4 MHz. The CAE amplitudes coincide both temporally and spatially with the onset of the excess heating. The high-k microwave scattering diagnostic and magnetic pickup coils were used to estimate the amplitudes of these modes. Full orbit calculations were then performed using these modes, which demonstrate that thermal ions can be heated by the CAEs. The Edge Neutral Density Diagnostic (ENDD

  10. Ion beam profiling from the interaction with a freestanding 2D layer

    Directory of Open Access Journals (Sweden)

    Ivan Shorubalko

    2017-03-01

    Full Text Available Recent years have seen a great potential of the focused ion beam (FIB technology for the nanometer-scale patterning of a freestanding two-dimensional (2D layer. Experimentally determined sputtering yields of the perforation process can be quantitatively explained using the binary collision theory. The main peculiarity of the interaction between the ion beams and the suspended 2D material lies in the absence of collision cascades, featured by no interaction volume. Thus, the patterning resolution is directly set by the beam diameters. Here, we demonstrate pattern resolution beyond the beam size and precise profiling of the focused ion beams. We find out that FIB exposure time of individual pixels can influence the resultant pore diameter. In return, the pore dimension as a function of the exposure dose brings out the ion beam profiles. Using this method of determining an ion-beam point spread function, we verify a Gaussian profile of focused gallium ion beams. Graphene sputtering yield is extracted from the normalization of the measured Gaussian profiles, given a total beam current. Interestingly, profiling of unbeknown helium ion beams in this way results in asymmetry of the profile. Even triangular beam shapes are observed at certain helium FIB conditions, possibly attributable to the trimer nature of the beam source. Our method of profiling ion beams with 2D-layer perforation provides more information on ion beam profiles than the conventional sharp-edge scan method does.

  11. Noncoaxial Bessel-Gauss beams.

    Science.gov (United States)

    Huang, Chaohong; Zheng, Yishu; Li, Hanqing

    2016-04-01

    We proposed a new family of noncoaxial Gauss-truncated Bessel beams through multiplying conventional symmetrical Bessel beams by a noncoaxial Gauss function. These beams can also be regarded as the exponential-truncated version of Bessel-Gauss beams since they can be transformed into the product of Bessel-Gauss beams and an exponential window function along a certain Cartesian axis. The closed-form solutions of the angular spectra and paraxial propagation of these beams were derived. These beams have asymmetrical intensity distributions and carry the same orbit angular momentum per photon as the corresponding Bessel-Gauss beams. While propagating along the z axis, the mth (m≠0) noncoaxial Bessel-Gauss beams rotate their intensity distributions and the mth-order vortex at the beam center has a transverse shift along the direction perpendicular to the offset axis. Depending on the product of the transverse scalar factor of the Bessel beams and the offset between the Gaussian window function and the center of the Bessel beams, the noncoaxial Bessel-Gauss beams can produce unit vortices with opposite signs in pairs during propagation.

  12. WORKSHOP: Beam cooling

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Cooling - the control of unruly particles to provide well-behaved beams - has become a major new tool in accelerator physics. The main approaches of electron cooling pioneered by Gersh Budker at Novosibirsk and stochastic cooling by Simon van der Meer at CERN, are now complemented by additional ideas, such as laser cooling of ions and ionization cooling of muons

  13. Neutrino beam plasma instability

    Indian Academy of Sciences (India)

    Abstract. We derive relativistic fluid set of equations for neutrinos and electrons from relativistic. Vlasov equations with Fermi weak interaction force. Using these fluid equations, we obtain a dis- persion relation describing neutrino beam plasma instability, which is little different from normal dispersion relation of streaming ...

  14. Neutrino beam plasma instability

    Indian Academy of Sciences (India)

    We derive relativistic fluid set of equations for neutrinos and electrons from relativistic Vlasov equations with Fermi weak interaction force. Using these fluid equations, we obtain a dispersion relation describing neutrino beam plasma instability, which is little different from normal dispersion relation of streaming instability.

  15. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  16. Beam profile monitor

    International Nuclear Information System (INIS)

    Krausse, G.J.; Gram, P.A.M.

    1978-05-01

    A system used to monitor secondary beam profiles at the LAMPF Linac for channel tune-up and diagnostics is described. The multiwire proportional chamber design is discussed, and descriptions and drawings of the gate card, the amplifier/multiplexer card, the output amplifier card, and the overall system are given

  17. Beam dynamics group summary

    Science.gov (United States)

    Peggs, S.

    This paper summarizes the activities of the beam dynamics working group of the LHC Collective Effects Workshop that was held in Montreux in 1994. It reviews the presentations that were made to the group, the discussions that ensued, and the consensuses that evolved.

  18. Dual beam vidicon digitizer

    International Nuclear Information System (INIS)

    Evans, T.L.

    1976-01-01

    A vidicon waveform digitizer which can simultaneously digitize two independent signals has been developed. Either transient or repetitive waveforms can be digitized with this system. A dual beam oscilloscope is used as the signal input device. The light from the oscilloscope traces is optically coupled to a television camera, where the signals are temporarily stored prior to digitizing

  19. Electron beam processing system

    International Nuclear Information System (INIS)

    Kashiwagi, Masayuki

    2004-01-01

    Electron beam Processing Systems (EPS) are used as useful and powerful tools in many industrial application fields such as the production of cross-linked wire, rubber tire, heat shrinkable film and tubing, curing, degradation of polymers, sterilization and environmental application. In this paper, the feature and application fields, the selection of machine ratings and safety measures of EPS will be described. (author)

  20. Ion beam studies

    International Nuclear Information System (INIS)

    Freeman, J.H.; Chivers, D.J.; Gard, G.A.; Temple, W.

    1977-04-01

    A description of techniques for the production of intense beams of heavy ions is given. A table of recommended operational procedures for most elements is included. The ionisation of boron is considered in some detail because of its particular importance as a dopant for ion implantation. (author)

  1. Beam in on curing

    International Nuclear Information System (INIS)

    Holl, Dr.

    1981-01-01

    Electron beam curing of paints and allied materials is discussed. Examples of applications are: silicone papers; painting of metal; bonding of flake adhesives; bonding of grinding media (binders); paints for external uses; painting shaped parts; bi-reactive painting systems. An example is given of the calculation of the cost of irradiation. (U.K.)

  2. Stochastic nonlinear beam equations

    Czech Academy of Sciences Publication Activity Database

    Brzezniak, Z.; Maslowski, Bohdan; Seidler, Jan

    2005-01-01

    Roč. 132, č. 1 (2005), s. 119-149 ISSN 0178-8051 R&D Projects: GA ČR(CZ) GA201/01/1197 Institutional research plan: CEZ:AV0Z10190503 Keywords : stochastic beam equation * stability Subject RIV: BA - General Mathematics Impact factor: 0.896, year: 2005

  3. LHC Report: Beam on

    CERN Multimedia

    Rossano Giachino for the LHC Team

    2012-01-01

    The powering tests described in the last edition of the Bulletin were successfully finished at the end of the first week of March opening the way for 4 TeV operations this year. The beam was back in the machine on Wednesday 14 March. The first collisions at 4 TeV are scheduled for the first week of April.   The first beam of 2012 is dumped after making a few rounds in the LHC. The magnet powering tests were followed by the machine checkout phase. Here the operations team in collaboration with the equipment groups performs a sequence of tests to ensure the readiness of the LHC for beam. The tests include driving all the LHC systems – beam dump, injection, collimation, RF, power converters, magnet circuits, vacuum, interlocks, controls, timing and synchronization – through the operational cycle. The “checkout phase” is really a massive de-bugging exercise, which is performed with the objective of ensuring the proper functioning of the whole machine and t...

  4. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...

  5. Recycled Paper Beam Sculpture

    Science.gov (United States)

    Keller, Kristin; Tabacchi, Jo

    2011-01-01

    As art department budgets across the country continue to shrink, art teachers are increasingly on the lookout for inexpensive materials that can be used to teach a range of concepts. In this article, the authors describe a newspaper beam tower project inspired by the book, "The Wonderful Towers of Watts" by Patricia Zelver. There are many more…

  6. Charged particle beams

    CERN Document Server

    Humphries, Stanley

    2013-01-01

    Detailed enough for a text and sufficiently comprehensive for a reference, this volume addresses topics vital to understanding high-power accelerators and high-brightness-charged particle beams. Subjects include stochastic cooling, high-brightness injectors, and the free electron laser. Humphries provides students with the critical skills necessary for the problem-solving insights unique to collective physics problems. 1990 edition.

  7. Nonlinear beam mechanics

    NARCIS (Netherlands)

    Westra, H.J.R.

    2012-01-01

    In this Thesis, nonlinear dynamics and nonlinear interactions are studied from a micromechanical point of view. Single and doubly clamped beams are used as model systems where nonlinearity plays an important role. The nonlinearity also gives rise to rich dynamic behavior with phenomena like

  8. Noninterceptive transverse beam diagnostics

    International Nuclear Information System (INIS)

    Chamberlin, D.D.; Minerbo, G.N.; Teel, L.E. Jr.; Gilpatrick, J.D.

    1981-01-01

    The transverse emittance properties of a high-current linear accelerator may be measured by using TV cameras sensitive to the visible radiation emitted following beam interactions with residual gas. This paper describes the TV system being used to measure emittances for the Fusion Materials Irradiation Test (FMIT) project

  9. Convergent beam neutron crystallography

    Science.gov (United States)

    Gibson, Walter M.; Schultz, Arthur J.; Richardson, James W.; Carpenter, John M.; Mildner, David F. R.; Chen-Mayer, Heather H.; Miller, M. E.; Maxey, E.; Prask, Henry J.; Gnaeupel-Herold, Thomas H.; Youngman, Russell

    2004-01-01

    Applications of neutron diffraction for small samples (small fiducial areas are limited by the available neutron flux density. Recent demonstrations of convergent beam electron and x-ray diffraction and focusing of cold (λ>1 Å) neutrons suggest the possibility to use convergent beam neutron diffraction for small sample crystallography. We have carried out a systematic study of diffraction of both monoenergetic and broad bandwidth neutrons at the NIST Research Reactor and at the Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory. Combining convergent beams with time-of-flight Laue diffraction is particularly attractive for high efficiency small sample diffraction studies. We have studied single crystal and powder diffraction of neutrons with convergence angles as large as 15° and have observed diffracted peak intensity gains greater than 20. The convergent beam method (CBM) shows promise for crystallography on small samples of small to medium size molecules (potentially even for proteins), ultra-high pressure samples, and for mapping of strain and texture distributions in larger samples.

  10. Beam Position Monitor Engineering

    International Nuclear Information System (INIS)

    Smith, Stephen R.

    1996-07-01

    The design of beam position monitors often involves challenging system design choices. Position transducers must be robust, accurate, and generate adequate position signal without unduly disturbing the beam. Electronics must be reliable and affordable, usually while meeting tough requirements on precision. accuracy, and dynamic range. These requirements may be difficult to achieve simultaneously, leading the designer into interesting opportunities for optimization or compromise. Some useful techniques and tools are shown. Both finite element analysis and analytic techniques will be used to investigate quasi-static aspects of electromagnetic fields such as the impedance of and the coupling of beam to striplines or buttons. Finite-element tools will be used to understand dynamic aspects of the electromagnetic fields of beams, such as wake-fields and transmission-line and cavity effects in vacuum-to-air feed through. Mathematical modeling of electrical signals through a processing chain will be demonstrated, in particular to illuminate areas where neither a pure time-domain nor a pure frequency-domain analysis is obviously advantageous. Emphasis will be on calculational techniques, in particular on using both time-domain and frequency domain approaches to the applicable parts of interesting problems

  11. Beam transport elements

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    Two of the beam transport elements for the slow ejection system. On the left, a quadrupole 1.2 m long with a 5 cm aperture, capable of producing a gradient of 5000 gauss. On the right, a 1 m bending magnet with a 4 cm gap; its field is 20 000 gauss.

  12. BATMAN beam properties characterization by the beam emission spectroscopy diagnostic

    Science.gov (United States)

    Bonomo, F.; Ruf, B.; Barbisan, M.; Cristofaro, S.; Schiesko, L.; Fantz, U.; Franzen, P.; Pasqualotto, R.; Riedl, R.; Serianni, G.; Wünderlich, D.

    2015-04-01

    The ITER neutral beam heating systems are based on the production and acceleration of negative ions (H/D) up to 1 MV. The requirements for the beam properties are strict: a low core beam divergence (BATMAN (BAvarian Test MAchine for Negative ions) allows for deepening the knowledge of the determination of the beam properties. One of the diagnostics routinely used to this purpose is the Beam Emission Spectroscopy (BES): the Hα light emitted in the beam is detected and the corresponding spectra are evaluated to estimate the beam divergence and the stripping losses. The BES number of lines of sight in BATMAN has been recently increased: five horizontal lines of sight providing a vertical profile of the beam permit to characterize the negative ion beam properties in relation to the source parameters. Different methods of Hα spectra analysis are here taken into account and compared for the estimation of the beam divergence and the amount of stripping. In particular, to thoroughly study the effect of the space charge compensation on the beam divergence, an additional hydrogen injection line has been added in the tank, which allows for setting different background pressure values (one order of magnitude, from about 0.04 Pa up to the source pressure) in the beam drift region.

  13. Poison Prevention

    Science.gov (United States)

    ... Prevention Listen Español Text Size Email Print Share Poison Prevention Page Content Article Body Post the Poison Help number 1-800-222-1222 on the ... or empty container of a toxic substance, call Poison Help immediately. More than a million American children ...

  14. Preventable amputations in Ethiopia

    African Journals Online (AJOL)

    Sew. Mi. 6. Discussion. Gas gangre. Total. This study thus confirms that at the present time about a half of the limbs being amputated at our. Hospital (and probably throughout Ethiopia) could have been saved, or prevented by relatively simple means. These include reducing the number of road traffic accident casualties by ...

  15. External beam radiation for retinoblastoma: Results, patterns of failure, and a proposal for treatment guidelines

    International Nuclear Information System (INIS)

    Hernandez, J. Carlos; Brady, Luther W.; Shields, Jerry A.; Shields, Carol L.; Potter, Patrick de; Karlsson, Ulf L.; Markoe, Arnold M.; Amendola, Beatriz E.; Singh, Arun

    1996-01-01

    Purpose: To analyze treatment results and patterns of failure following external beam radiation for retinoblastoma and propose treatment guidelines according to specific clinical variables. Methods and Materials: We analyzed 27 patients (34 eyes) with retinoblastoma who received external beam radiation as initial treatment at Hahnemann University Hospital from October 1980 to December 1991 and have been followed for at least 1 year. Of the 34 eyes, 14 were Groups I-II (Reese-Ellsworth classification), 7 were Group III, and 13 were Groups IV-V. Doses ranged from 34.5-49.5 Gy (mean 44.3 Gy, median 45 Gy) in 1.5-2.0 Gy fractions generally delivered through anterior and lateral wedged pair fields. Results: At a mean follow up of 35.2 months (range 12-93 months), local tumor control was obtained in 44% (15 out of 34) of eyes with external beam radiation alone. Salvage therapy (plaque brachytherapy, cryotherapy, and/or photocoagulation) controlled an additional 10 eyes (29.5%), so that overall ocular survival has been 73.5%. Local tumor control with external beam radiotherapy alone was obtained in 78.5% (11 out of 14) of eyes in Groups I-II, but in only 20% (4 out of 20) of eyes in Groups III-V. A total of 67 existing tumors were identified prior to treatment in the 34 treated eyes and local control with external beam radiation alone was obtained in 87% (46 out of 53) of tumors measuring 15 mm or less and in 50% (7 out of 14) of tumors measuring more than 15 mm. When analyzing patterns of failure in the 19 eyes that relapsed, a total of 28 failure sites were identified and consisted of progression of vitreous seeds in seven instances (25% of failure sites) recurrences from previously existing tumors in 10 instances (36% of failure sites) and development of new tumors in previously uninvolved retina in 11 instances (39% of failure sites). Conclusions: 1) We find that external beam radiation to a dose of 45 Gy in fractions of 1.5 to 2.0 Gy provides adequate tumor control

  16. The effect of concrete strength and reinforcement on toughness of reinforced concrete beams

    OpenAIRE

    Carneiro, Joaquim A. O.; Jalali, Said; Teixeira, Vasco M. P.; Tomás, M.

    2005-01-01

    The objective pursued with this work includes the evaluating of the strength and the total energy absorption capacity (toughness) of reinforced concrete beams using different amounts of steel-bar reinforcement. The experimental campaign deals with the evaluation of the threshold load prior collapse, ultimate load and deformation, as well as the beam total energy absorption capacity, using a three point bending test. The beam half span displacement was measured using a displacement transducer,...

  17. Ion beam characteristics of a gas filled accelerator tube

    International Nuclear Information System (INIS)

    Berg, R.S.; Bickes, R.W. Jr.; Boers, J.E.; Shope, L.A.

    1980-01-01

    A gas filled tube used to produce a pulsed neutron flux with the D(T, 4 He)n reaction is described. Deuterium and tritium ions generated in a reflex discharge are extracted and accelerated to 100 keV by means of an accelerator electrode onto a deutero-tritide target electrode. The electrodes are designed to focus the ion beam onto the target. Total tube currents consisting of extracted ions, unsuppressed secondary electrons, and ions generated by interactions with the background gas are typically 100mA. Characteristics of the extracted ion beam are discussed. Accelerating voltages greater than 50kV are required to focus the beam through the accelerator aperture for configurations that give beams with the proper energy density at the target. The perveance of the beam is defined. Maximum perveance values are 2 to 10 nanopervs. Tube focussing and neutron production characteristics are described

  18. An Electronically Controlled 8-Element Switched Beam Planar Array

    KAUST Repository

    Sharawi, Mohammad S.

    2015-02-24

    An 8-element planar antenna array with electronically controlled switchable-beam pattern is proposed. The planar antenna array consists of patch elements and operates in the 2.45 GHz ISM band. The array is integrated with a digitally controlled feed network that provides the required phases to generate 8 fixed beams covering most of the upper hemisphere of the array. Unlike typical switchable beam antenna arrays, which operate only in one plane, the proposed design is the first to provide full 3D switchable beams with simple control. Only a 3-bit digital word is required for the generation of the 8 different beams. The integrated array is designed on a 3-layer PCB on a Taconic substrate (RF60A). The total dimensions of the fabricated array are 187.1 × 261.3 × 1.3mm3.

  19. Final design of kaon beam K2 at KEK

    International Nuclear Information System (INIS)

    Kurokawa, Shin-ichi; Yamamoto, Akira.

    1977-09-01

    Final design of the 2.3 GeV/c kaon beam K2 is given. The K2 beam starts from the production target in slow extracted beam. Momentum range is 1 GeV/c through 2.3 GeV/c. Nominal total beam length is 27.9 m and solid-angle momentum acceptance is 6.25 msr%ΔP/P. Using a platinum target of diameter 3 mm and length 6 cm, 2.0 GeV/c beam fluxes of 1.0 x 10 6 K + and 5.2 x 10 5 K - per 10 12 13 GeV/c incident protons are expected at the final focus. (auth.)

  20. Large area electron beam diode development

    International Nuclear Information System (INIS)

    Helava, H.; Gilman, C.M.; Stringfield, R.M.; Young, T.

    1983-01-01

    A large area annular electron beam diode has been tested at Physics International Co. on the multi-terawatt PITHON generator. A twelve element post hole convolute converted the coaxial MITL into a triaxial arrangement of anode current return structures both inside and outside the cathode structure. The presence of both inner and outer current return paths provide magnetic pressure balance for the beam, as determined by diode current measurements. X-ray pinhole photographs indicated uniform emission with intensity maxima between the post positions. Current losses in the post hole region were negligible, as evidenced by the absence of damage to the aluminum hardware. Radial electron flow near the cathode ring however did damage the inner anode cylinder between the post positions. Cutting away these regions prevented further damage of the transmission lines

  1. Beam limiter for thermonuclear fusion devices

    International Nuclear Information System (INIS)

    Kaminsky, M.S.

    1976-01-01

    A beam limiter circumscribes the interior surface of a vacuum vessel to inhibit collisions of contained plasma and the vessel walls. The cross section of the material making up the limiter has a flatsided or slightly concave portion of increased width towards the plasma and portions of decreased width towards the interior surface of the vessel. This configuration is designed to prevent a major fraction of the material sputtered, vaporized and blistered from the limiter from reaching the plasma. It also allows adequate heat transfer from the wider to the narrower portions. The preferred materials for the beam limiter are solids of sintered, particulate materials of low atomic number with low vapor pressure and low sputtering and blistering yields. 7 claims, 3 figures

  2. Totally Nonnegative Matrices

    CERN Document Server

    Fallat, Shaun M

    2011-01-01

    Totally nonnegative matrices arise in a remarkable variety of mathematical applications. This book is a comprehensive and self-contained study of the essential theory of totally nonnegative matrices, defined by the nonnegativity of all subdeterminants. It explores methodological background, historical highlights of key ideas, and specialized topics.The book uses classical and ad hoc tools, but a unifying theme is the elementary bidiagonal factorization, which has emerged as the single most important tool for this particular class of matrices. Recent work has shown that bidiagonal factorization

  3. Coherent Forward Stimulated-Brillouin Scattering of a Spatially Incoherent Laser Beam in a Plasma and Its Effect on Beam Spray

    International Nuclear Information System (INIS)

    Grech, M.; Riazuelo, G.; Pesme, D.; Weber, S.; Tikhonchuk, V. T.

    2009-01-01

    A statistical model for forward stimulated-Brillouin scattering is developed for a spatially incoherent, monochromatic, laser beam propagating in a plasma. The threshold above which the laser beam spatial incoherence cannot prevent the coherent growth of forward stimulated-Brillouin scattering is computed. It is found to be well below the threshold for self-focusing. Three-dimensional simulations confirm its existence and reveal the onset of beam spray above it. From these results, we propose a new figure of merit for the control of propagation through a plasma of a spatially incoherent laser beam

  4. The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study

    CERN Document Server

    Parodi, K; Kraemer, M; Sommerer, F; Naumann, J; Mairani, A; Brons, S

    2010-01-01

    Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been an...

  5. Improvements in or relating to the control of beams of electromagnetic radiation

    International Nuclear Information System (INIS)

    Cecil, M.M.; Michaelis, S.; Rumsby, P.T.

    1981-01-01

    A method of controlling the passage of a beam of laser radiation comprises generating in the beam path a transitory plasma of a density such as to prevent passage of the beam through the plasma. The apparatus comprises an evacuated chamber, with transparent walls and having means for generating at least 3 plasma plumes which coalesce in a localised region of the chamber. (U.K.)

  6. A beam source model for scanned proton beams.

    Science.gov (United States)

    Kimstrand, Peter; Traneus, Erik; Ahnesjö, Anders; Grusell, Erik; Glimelius, Bengt; Tilly, Nina

    2007-06-07

    A beam source model, i.e. a model for the initial phase space of the beam, for scanned proton beams has been developed. The beam source model is based on parameterized particle sources with characteristics found by fitting towards measured data per individual beam line. A specific aim for this beam source model is to make it applicable to the majority of the various proton beam systems currently available or under development, with the overall purpose to drive dose calculations in proton beam treatment planning. The proton beam phase space is characterized by an energy spectrum, radial and angular distributions and deflections for the non-modulated elementary pencil beam. The beam propagation through the scanning magnets is modelled by applying experimentally determined focal points for each scanning dimension. The radial and angular distribution parameters are deduced from measured two-dimensional fluence distributions of the elementary beam in air. The energy spectrum is extracted from a depth dose distribution for a fixed broad beam scan pattern measured in water. The impact of a multi-slab range shifter for energy modulation is calculated with an own Monte Carlo code taking multiple scattering, energy loss and straggling, non-elastic and elastic nuclear interactions in the slab assembly into account. Measurements for characterization and verification have been performed with the scanning proton beam system at The Svedberg Laboratory in Uppsala. Both in-air fluence patterns and dose points located in a water phantom were used. For verification, dose-in-water was calculated with the Monte Carlo code GEANT 3.21 instead of using a clinical dose engine with approximations of its own. For a set of four individual pencil beams, both with the full energy and range shifted, 96.5% (99.8%) of the tested dose points satisfied the 1%/1 mm (2%/2 mm) gamma criterion.

  7. Computer simulation of electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Sabchevski, S.P.; Mladenov, G.M. (Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. po Elektronika)

    1994-04-14

    Self-fields and forces as well as the local degree of space-charge neutralization in overcompensated electron beams are considered. The radial variation of the local degree of space-charge neutralization is analysed. A novel model which describes the equilibrium potential distribution in overcompensated beams is proposed and a method for computer simulation of the beam propagation is described. Results from numerical experiments which illustrate the propagation of finite emittance overneutralized beams are presented. (Author).

  8. Polarized atomic beams for targets

    International Nuclear Information System (INIS)

    Grueebler, W.

    1984-01-01

    The basic principle of the production of polarized atomic hydrogen and deuterium beams are reviewed. The status of the present available polarization, density and intensity are presented. The improvement of atomic beam density by cooling the hydrogen atoms to low velocity is discussed. The possible use of polarized atomic beams as targets in storage rings is shown. It is proposed that polarized atomic beams can be used to produce polarized gas targets with high polarization and greatly improved density

  9. Total Water Management - Report

    Science.gov (United States)

    There is a growing need for urban water managers to take a more holistic view of their water resource systems as population growth, urbanization, and current operations put different stresses on the environment and urban infrastructure. Total Water Management (TWM) is an approac...

  10. Total knee arthroplasty

    DEFF Research Database (Denmark)

    Schrøder, Henrik M.; Petersen, Michael M.

    2016-01-01

    Total knee arthroplasty (TKA) is a successful treatment of the osteoarthritic knee, which has increased dramatically over the last 30 years. The indication is a painful osteoarthritic knee with relevant radiographic findings and failure of conservative measures like painkillers and exercise...

  11. Total versus subtotal hysterectomy

    DEFF Research Database (Denmark)

    Gimbel, Helga; Zobbe, Vibeke; Andersen, Anna Birthe

    2005-01-01

    The aim of this study was to compare total and subtotal abdominal hysterectomy for benign indications, with regard to urinary incontinence, postoperative complications, quality of life (SF-36), constipation, prolapse, satisfaction with sexual life, and pelvic pain at 1-year postoperative. Eighty...

  12. Total Quality Management Seminar.

    Science.gov (United States)

    Massachusetts Career Development Inst., Springfield.

    This booklet is one of six texts from a workplace literacy curriculum designed to assist learners in facing the increased demands of the workplace. The booklet contains seven sections that cover the following topics: (1) meaning of total quality management (TQM); (2) the customer; (3) the organization's culture; (4) comparison of management…

  13. Total Quality Management Simplified.

    Science.gov (United States)

    Arias, Pam

    1995-01-01

    Maintains that Total Quality Management (TQM) is one method that helps to monitor and improve the quality of child care. Lists four steps for a child-care center to design and implement its own TQM program. Suggests that quality assurance in child-care settings is an ongoing process, and that TQM programs help in providing consistent, high-quality…

  14. Total synthesis of aquatolide

    NARCIS (Netherlands)

    Saya, J.M.; Vos, K.; Klein Nijenhuis, R.A.; van Maarseveen, J.H.; Ingemann, S.; Hiemstra, H.

    2015-01-01

    A total synthesis of the sesquiterpene lactone aquatolide has been accomplished. The central step is an intramolecular [2 + 2]-photocycloaddition of an allene onto an alpha,beta-unsaturated delta-lactone. Other key steps are an intramolecular Horner-Wadsworth-Emmons reaction to close the lactone and

  15. CSF total protein

    Science.gov (United States)

    CSF total protein is a test to determine the amount of protein in your spinal fluid, also called cerebrospinal fluid (CSF). ... The normal protein range varies from lab to lab, but is typically about 15 to 60 milligrams per deciliter (mg/dL) ...

  16. Total 2004 annual report

    International Nuclear Information System (INIS)

    2004-01-01

    This annual report of the Group Total brings information and economic data on the following topics, for the year 2004: the corporate governance, the corporate social responsibility, the shareholder notebook, the management report, the activities, the upstream (exploration and production) and downstream (refining and marketing) operating, chemicals and other matters. (A.L.B.)

  17. Total Cost of Ownership

    DEFF Research Database (Denmark)

    Zachariassen, Frederik

    2007-01-01

    Total Cost of Ownership (TCO), som giver et bud på, hvordan virksomheder kan opnå en bedre indsigt i, hvilke leverandører der forårsager hvilke omkostninger og dermed danne et forbedret beslutningsgrundlag for besparelser i leverandørleddet. I artiklen argumenteres først og fremmest for, hvorfor TCO er...

  18. Study of beam-beam long range compensation with octupoles

    CERN Document Server

    AUTHOR|(CDS)2068329; Pieloni, Tatiana; Buffat, Xavier; Tambasco, Claudia

    2017-01-01

    Long range beam-beam effects are responsible for particle losses and define fundamental operational parameters of colliders (i.e. crossing angles, intensities, emittances, ${\\beta}$${^∗}$). In this study we propose octuple magnets as a possible scheme to efficiently compensate long-range beam-beam interactions with a global correction scheme. The impact and improvements on the dynamic aperture of colliding beams together with estimates of the luminosity potentials are dis- cussed for the HL-LHC upgrade and extrapolations made for the FCC project.

  19. Beam Dynamics Simulation for the CTF3 Drive Beam Accelerator

    CERN Document Server

    Schulte, Daniel

    2000-01-01

    A new CLIC Test Facility (CTF3) at CERN will serve to study the drive beam generation for the Compact Linear Collider (CLIC). CTF3 has to accelerate a 3.5 A electron beam in almost fully-loaded structures. The pulse contains more than 2000 bunches, one in every second RF bucket, and has a length of more than one microsecond. Different options for the lattice of the drive-beam accelerator are presented, based on FODO-cells and triplets as well as solenoids. The transverse stability is simulated, including the effects of beam jitter, alignment and beam-based correction.

  20. Single Gradientless Light Beam Drags Particles as Tractor Beams

    DEFF Research Database (Denmark)

    Novitsky, Andrey; Qiu, Cheng-Wei; Wang, Haifeng

    2011-01-01

    is the strong nonparaxiality of the light beam, which contributes to the pulling force owing to momentum conservation. The nonparaxiality of the Bessel beam can be manipulated to possess a dragging force along both the radial longitudinal directions, i.e., a "tractor beam" with stable trajectories is achieved......Usually a light beam pushes a particle when the photons act upon it. We investigate the optical forces by nonparaxial gradientless beams and find that the forces can drag suitable particles all the way towards the light source. The major criterion of realizing the backward dragging force...

  1. Spatial superpositions of Gaussian beams

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2014-02-01

    Full Text Available ., “Bottle beam from a bare laser for single-beam trapping,” Appl. Opt. 43, 6001–6006 (2004). [11] Ahluwalia B. P. S., Yuan X. C. and Tao S. H., “Generation of self-imaged optical bottle beams,” Opt. Commun. 238, 177–184 (2004). [12] Isenhower L...

  2. Nuclear physics with radioactive beams

    International Nuclear Information System (INIS)

    Bimbot, R.

    1994-01-01

    Radioactive beam production through two different mechanisms: acceleration of radioactive nuclei, and production of secondary beams from projectile fragmentation is overviewed. Some topics of the applications of radioactive beams in nuclear physics, such as identification and study of exotic nuclei, neutron halos, nuclear astrophysics and medical applications are discussed. (K.A.). 24 refs., 8 figs

  3. Flat profile laser beam shaper

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Todd R.

    2017-09-12

    A system for shaping a beam comprises an emitter for emitting coherent electromagnetic radiation. Birefringent displacers are configured between the emitter and a target wherein the at least two birefringent displacers split the coherent electromagnetic radiation into a plurality of coherent parallel beams of electromagnetic radiation thereby producing a shaped wave front of the coherent parallel beams of electromagnetic radiation.

  4. Planck 2015 results: IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Ashdown, M.

    2016-01-01

    are used for the computation of the effective beam window functions. The error budget for the window functions is estimated from both main beam and sidelobe contributions, and accounts for the radiometer band shapes. The total uncertainties in the effective beam window functions are 0.7% and 1% at 30......This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013 Planck release; the main differences concern the beam...... normalization and the delivery of the window functions to be used for polarization analysis. The in-flight assessment of the LFI main beams relies on measurements performed during observations of Jupiter. By stacking data from seven Jupiter transits, the main beam profiles are measured down to -25 dB at 30...

  5. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2014-01-01

    functions was estimated considering both main beam and sidelobe contributions, as well as taking into account the radiometer bandshapes. The total uncertainties in the effective beam window functions are: (at ell = 600) 2% and 1.2% at 30 and 44 GHz, respectively; and at ell = 1000, 0.7% at 70 GHz.......This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky...... anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relied...

  6. Planck 2013 results. IV. Low Frequency Instrument beams and window functions

    DEFF Research Database (Denmark)

    Planck Collaboration,; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    functions was estimated considering both main beam and sidelobe contributions, as well as taking into account the radiometer bandshapes. The total uncertainties in the effective beam window functions are: (at ell = 600) 2% and 1.2% at 30 and 44 GHz, respectively; and at ell = 1000, 0.7% at 70 GHz.......This paper presents the characterization of the in-flight beams, the beam window functions and the associated errors for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is the key to determining their imprint on the transfer function from the observed to the actual sky...... anisotropy power spectrum. The main beam distortions affect the beam window function, complicating the reconstruction of the anisotropy power spectrum at high multipoles, whereas the sidelobes affect the low and intermediate multipoles. The in-flight assessment of the LFI main beams relied...

  7. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  8. Preventive analgesia

    DEFF Research Database (Denmark)

    Dahl, Jørgen B; Kehlet, Henrik

    2011-01-01

    This paper will discuss the concepts of pre-emptive and preventive analgesia in acute and persistent postsurgical pain, based on the most recent experimental and clinical literature, with a special focus on injury-induced central sensitization and the development from acute to chronic pain. Recent...... of preventive analgesia for persistent postoperative pain are promising. However, clinicians must be aware of the demands for improved design of their clinical studies in order to get more conclusive answers regarding the different avenues for intervention. Summary: The concept of preventive analgesia is still...

  9. Closed orbit distortion and the beam-beam interaction

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M.; Chin, Y.H.; Eden, J. [Lawrence Berkeley Lab., CA (United States); Kozanecki, W. [CEA Centre d`Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)]|[Stanford Linear Accelerator Center, Menlo Park, CA (United States); Tennyson, J.; Ziemann, V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1992-06-01

    We study the applicability of beam-beam deflection techniques as a tuning tool for the SLAC/LBL/LLNL B factory, PEP-II. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measurements, performed at points conveniently distant from the IP, provide distinct coordinate- or frequency-space signatures that can be used to maintain the beams in collision and perform detailed optical diagnostics at the IP. A proposal to test this method experimentally at the TRISTAN ring is briefly discussed.

  10. Coherent Beam-Beam Effects in the LHC

    CERN Document Server

    Alexahin, Yu I; Herr, Werner; Zorzano-Mier, M P

    2001-01-01

    In the Large Hadron Collider (LHC) two proton beams of similar intensities collide in several interaction points. It is well known that the head-on collision of two beams of equal strength can excite coherent modes whose frequencies are separated from the incoherent spectrum of oscillations of individual particles. This can lead to the loss of Landau damping and possibly to unstable motion. The beam-beam effect in the LHC is further complicated by a large number of bunches (2808 per beam), a finite crossing angle and gaps in the bunch train. The coherent beam-beam effects under various conditions and operational scenarios are studied analytically and with multiparticle simulations. We give an overview of the main results and present proposals to overcome these difficulties together with possible side effects.

  11. Total Value of Phosphorus Recovery.

    Science.gov (United States)

    Mayer, Brooke K; Baker, Lawrence A; Boyer, Treavor H; Drechsel, Pay; Gifford, Mac; Hanjra, Munir A; Parameswaran, Prathap; Stoltzfus, Jared; Westerhoff, Paul; Rittmann, Bruce E

    2016-07-05

    Phosphorus (P) is a critical, geographically concentrated, nonrenewable resource necessary to support global food production. In excess (e.g., due to runoff or wastewater discharges), P is also a primary cause of eutrophication. To reconcile the simultaneous shortage and overabundance of P, lost P flows must be recovered and reused, alongside improvements in P-use efficiency. While this motivation is increasingly being recognized, little P recovery is practiced today, as recovered P generally cannot compete with the relatively low cost of mined P. Therefore, P is often captured to prevent its release into the environment without beneficial recovery and reuse. However, additional incentives for P recovery emerge when accounting for the total value of P recovery. This article provides a comprehensive overview of the range of benefits of recovering P from waste streams, i.e., the total value of recovering P. This approach accounts for P products, as well as other assets that are associated with P and can be recovered in parallel, such as energy, nitrogen, metals and minerals, and water. Additionally, P recovery provides valuable services to society and the environment by protecting and improving environmental quality, enhancing efficiency of waste treatment facilities, and improving food security and social equity. The needs to make P recovery a reality are also discussed, including business models, bottlenecks, and policy and education strategies.

  12. Design of fast kickers for the ISABELLE beam abort system

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Montemurro, P.A.; Baron, J.

    1981-01-01

    The ISA beam abort (extraction) system must be highly efficient, in the sense of producing minimum beam loss, and reliable to prevent serious damage to accelerator components by the circulating high-energy beams. Since the stored beams will be debunched, the low-loss requirement can be met only with ultra-thin extraction septa and/or fast-acting kickers. This paper examines the design of the ISA extraction kickers subject to a set of extraction channel constraints and a given maximum working voltage. Expressions are derived for determining system parameters for both a lumped parameter magnet and a delay-line magnet. Using these relationships, design parameters are worked out for several possible system configurations. The paper also describes the construction of a full-scale prototype module of the kicker and summarizes the preliminary test results obtained with the module

  13. Flexural Behavior of Corroded Reinforced Recycled Aggregate Concrete Beams

    Directory of Open Access Journals (Sweden)

    Taoping Ye

    2018-01-01

    Full Text Available Recycling concrete not only reduces the use of virgin aggregate but also decreases the pressure on landfills. As a result, recycled coarse aggregate (RCA is extensively recommended for new construction projects. However, the flexural behavior of corroded reinforced recycled aggregate concrete (RAC beams is uncertain. The experimental research presented in this paper was performed to investigate the flexural behavior of corroded reinforced RAC beams compared to that of corroded reinforced natural aggregate concrete (NAC beams and consequently explore the possibility of using RAC beams in corrosive environments. Four different percentages of RCA in total mass of coarse aggregate in concrete mixtures (0%, 33%, 66%, and 100% and two different concrete strengths (C30, C60 were the governing parameters. The electrochemical method was adopted to accelerate steel corrosion. Full-scale tests were performed on eight simply supported beams until the failure load was reached. Comparison of load-deflection behavior, crack patterns, failure modes, ductility, and ultimate flexural capacity of corroded reinforced NAC and RAC beams was made based on the experimental results obtained. The comparison results show that the flexural behavior of corroded reinforced RAC beams with an appropriate percentage of RCA is satisfactory compared to the behavior of NAC beams.

  14. Repair of reinforced concrete beams using carbon fiber reinforced polymer

    Directory of Open Access Journals (Sweden)

    Karzad Abdul Saboor

    2017-01-01

    Full Text Available This research paper is part of an ongoing research on the behaviour of Reinforced Concrete (RC beams retrofitted with Externally Bonded Carbon Fiber Reinforced Polymer (EB-CFRP. A total of 5 large-scale rectangular beams, previously damaged due to shear loading, were repaired and strengthened with EB-CFRP and tested in this study. The major cracks of the damaged beams were injected with epoxy and the beams were wrapped with 2 layers of EB-CFRP discrete strips with 100mm width and 150mm center to center spacing. The beams were instrumented and tested to failure under three points loading in simply supported configuration. The measured test parameters were the beams deflection, maximum load, and the strain in the FRP strips. The failure mode was also observed. The results showed that applying EB-FRP strips increased the shear strength significantly relative to the original shear capacity of the beam. The results demonstrate that the application of EB-FRP strips used in this study is an effective repair method that can be used to repair and strengthen damaged beams.

  15. Emittance growth and halo formation in charge-dominated beams

    Energy Technology Data Exchange (ETDEWEB)

    Bondarev, B.I.; Durkin, A.P.; Murin, B.P. [Moscow Radiotechnical Institute (Russian Federation)] [and others

    1995-10-01

    The optimization of high-current high-energy linacs against the low beam loss requirement is not straightforward or well-codified. Outlying particle losses at the 10{sup {minus}5} up to 10{sup {minus}8} level might have only a small effect on the rms properties of the beam, and thus the total beam size must be constantly kept under observation. RMS-physics has gained wide-spread acceptance as a necessary design tool, but its sufficiency is an issue for ATW/ABC accelerators.

  16. Prevention: Exercise

    Medline Plus

    Full Text Available ... Exercise Strength Training for the Elderly Other Back Pack Safety Pregnancy and Back Pain Preventing Osteoporosis Back ... in very slightly. Hold a ball directly in front of you. Keep your abdominal muscles tight and ...

  17. Prevention: Exercise

    Medline Plus

    Full Text Available ... Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! Stretching/Flexibility Aerobic ... Strength Training for the Elderly Other Back Pack Safety Pregnancy and Back Pain Preventing Osteoporosis Back Pain ...

  18. Prevent Shingles

    Science.gov (United States)

    ... Submit What's this? Submit Button Past Emails Prevent Shingles Language: English (US) Español (Spanish) Recommend on Facebook ... that can result in vision loss. Older Adults & Shingles As you get older, you are more likely ...

  19. Prevention: Exercise

    Medline Plus

    Full Text Available ... Epidural Steroid Injections Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient Safety Exercise Strengthening Strengthen Your Core! ...

  20. Prevention: Exercise

    Medline Plus

    Full Text Available ... and Education Injection Treatments for Spinal Pain Epidural Steroid Injections Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle ... Z Spine Specialists Videos 9 for Spine Epidural Steroid Injections Exercise: The Backbone of Spine Treatment Spondylolisthesis ...

  1. Prevention: Exercise

    Medline Plus

    Full Text Available ... A SPECIALIST Prevention Strengthening Exercise Committee Exercise Committee Core Strengthening Many popular forms of exercise focus on ... acute pain, you should stop doing it. Transverse Core Strengthening This strengthens the muscles that cross from ...

  2. Prevention: Exercise

    Medline Plus

    Full Text Available ... Lumbar Zygapophysical (Facet) Joint Injections PREVENTION Lifestyle Choices 10 Tips for a Healthy Back Smoking Weight Patient ... the floor; rotate from side to side. Repeat 10 times. Check with your physician; if you are ...

  3. Prevention: Exercise

    Medline Plus

    Full Text Available ... Pregnancy and Back Pain Preventing Osteoporosis Back Pain Basics Book RESOURCES Patient ... popular forms of exercise focus on core strengthening, or building the muscles that provide support for your body. Pilates, yoga and martial arts ...

  4. Heavy ion beam probing

    Energy Technology Data Exchange (ETDEWEB)

    Hickok, R L

    1980-07-01

    This report consists of the notes distributed to the participants at the IEEE Mini-Course on Modern Plasma Diagnostics that was held in Madison, Wisconsin in May 1980. It presents an overview of Heavy Ion Beam Probing that briefly describes the principles and discuss the types of measurements that can be made. The problems associated with implementing beam probes are noted, possible variations are described, estimated costs of present day systems, and the scaling requirements for large plasma devices are presented. The final chapter illustrates typical results that have been obtained on a variety of plasma devices. No detailed calculations are included in the report, but a list of references that will provide more detailed information is included.

  5. Heavy ion beam probing

    International Nuclear Information System (INIS)

    Hickok, R.L.

    1980-07-01

    This report consists of the notes distributed to the participants at the IEEE Mini-Course on Modern Plasma Diagnostics that was held in Madison, Wisconsin in May 1980. It presents an overview of Heavy Ion Beam Probing that briefly describes the principles and discuss the types of measurements that can be made. The problems associated with implementing beam probes are noted, possible variations are described, estimated costs of present day systems, and the scaling requirements for large plasma devices are presented. The final chapter illustrates typical results that have been obtained on a variety of plasma devices. No detailed calculations are included in the report, but a list of references that will provide more detailed information is included

  6. A simple beam analyser

    International Nuclear Information System (INIS)

    Lemarchand, G.

    1977-01-01

    (ee'p) experiments allow to measure the missing energy distribution as well as the momentum distribution of the extracted proton in the nucleus versus the missing energy. Such experiments are presently conducted on SACLAY's A.L.S. 300 Linac. Electrons and protons are respectively analysed by two spectrometers and detected in their focal planes. Counting rates are usually low and include time coincidences and accidentals. Signal-to-noise ratio is dependent on the physics of the experiment and the resolution of the coincidence, therefore it is mandatory to get a beam current distribution as flat as possible. Using new technologies has allowed to monitor in real time the behavior of the beam pulse and determine when the duty cycle can be considered as being good with respect to a numerical basis

  7. Focused ion beam technology

    International Nuclear Information System (INIS)

    Gamo, K.

    1993-01-01

    Focussed ion beam (FIB) technology has the advantage of being a maskless process compatible with UHV processing. This makes it attractive for use in in situ processing and has been applied to the fabrication of various mesoscopic structures. The present paper reviews these results whilst putting emphasis on in situ processing by a combined FIB and molecular beam epitaxy system. The typical performance of present FIB systems is also presented. In order to utilize the potential advantages of FIB processing, reduction of damage and improvement of throughput are important, and much effort has been devoted to developing processing techniques which require a reduced dose. The importance of low-energy FIB is discussed. (author)

  8. Total design of participation

    DEFF Research Database (Denmark)

    Munch, Anders V.

    2016-01-01

    The idea of design as an art made not only for the people, but also by the people is an old dream going back at least to William Morris. It is, however, reappearing vigoriously in many kinds of design activism and grows out of the visions of a Total Design of society. The ideas of participation b...... for? To which degree should everyone be educated in ’design literacy’ to participate? Total design of participation is an artistic intervention in society and must be discussed in this utopian tradition....... by Tim Brown can be compared to considerations by László Moholy-Nagy and Walter Gropuis on the training and education of active and capable citizens. This opens, though, some dilemmas to discuss: To what extend is the capability of creativity then a (pre)condition to be a citizen of the society wished...

  9. TOTAL PERFORMANCE SCORECARD

    Directory of Open Access Journals (Sweden)

    Anca ȘERBAN

    2013-06-01

    Full Text Available The purpose of this paper is to present the evolution of the Balanced Scorecard from a measurement instrument to a strategic performance management tool and to highlight the advantages of implementing the Total Performance Scorecard, especially for Human Resource Management. The study has been accomplished using the methodology of bibliographic study and various secondary sources. Implementing the classical Balanced Scorecard indicated over the years, repeatedly failure. It can be indicated that the crucial level is determined by the learning and growth perspective. It has been developed from a human perspective, which focused on staff satisfaction, innovation perspective with focus on future developments. Integrating the Total Performance Scorecard in an overall framework assures the company’s success, by keeping track of the individual goals, the company’s objectives and strategic directions. Like this, individual identity can be linked to corporate brand, individual aspirations to business goals and individual learning objectives to needed organizational capabilities.

  10. Total 2003 Results

    International Nuclear Information System (INIS)

    2003-01-01

    This document presents the 2003 results of Total Group: consolidated account, special items, number of shares, market environment, 4. quarter 2003 results, full year 2003 results, upstream (key figures, proved reserves), downstream key figures, chemicals key figures, parent company accounts and proposed dividends, 2004 sensitivities, summary and outlook, operating information by segment for the 4. quarter and full year 2003: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refinery throughput by region, refined product sales by region, chemicals), impact of allocating contribution of Cepsa to net operating income by business segment: equity in income (loss) and affiliates and other items, Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  11. Outpatient Total Joint Arthroplasty.

    Science.gov (United States)

    Bert, Jack M; Hooper, Jessica; Moen, Sam

    2017-12-01

    Outpatient total joint arthroplasty (OTJA) allows for a safe, cost effective pathway for appropriately selected patients. With current pressures on arthroplasty surgeons and their associated institutions to reduce costs per episode of care, it is important to define the steps and challenges associated with establishing an outpatient arthroplasty program. Several studies have outlined techniques of selecting patients suitable for this type of postoperative pathway. With emerging concerns about patients who undergo outpatient arthroplasty being at increased risk of medical complications, which may lessen projected cost savings, it is important to identify value-based strategies to optimize patient recovery after OTJA. This article reviews digital techniques for patient selection and data collection, operating room efficiency systems, and provides a summary of methods to build and maintain value in outpatient total joint replacement within the framework of bundled payment reimbursement.

  12. Totally parallel multilevel algorithms

    Science.gov (United States)

    Frederickson, Paul O.

    1988-01-01

    Four totally parallel algorithms for the solution of a sparse linear system have common characteristics which become quite apparent when they are implemented on a highly parallel hypercube such as the CM2. These four algorithms are Parallel Superconvergent Multigrid (PSMG) of Frederickson and McBryan, Robust Multigrid (RMG) of Hackbusch, the FFT based Spectral Algorithm, and Parallel Cyclic Reduction. In fact, all four can be formulated as particular cases of the same totally parallel multilevel algorithm, which are referred to as TPMA. In certain cases the spectral radius of TPMA is zero, and it is recognized to be a direct algorithm. In many other cases the spectral radius, although not zero, is small enough that a single iteration per timestep keeps the local error within the required tolerance.

  13. Electron beams in radiation therapy

    International Nuclear Information System (INIS)

    Bruinvis, I.A.D.

    1987-01-01

    Clinical electron beams in interaction with beam flattening and collimating devices are studied, in order to obtain the means for adequate electron therapy. A treatment planning method for arbitrary field shapes is developed that takes the properties of the collimated electron beams into account. An electron multiple-scattering model is extended to incorporate a model for the loss of electrons with depth, in order to improve electron beam dose planning. A study of ionisation measurements in two different phantom materials yields correction factors for electron beam dosimetry. (Auth.)

  14. Total quality accounting

    OpenAIRE

    Andrijašević Maja

    2008-01-01

    The focus of competitive "battle" shifted from the price towards non-price instruments, above all, towards quality that became the key variable for profitability increase and achievement of better comparative position of a company. Under such conditions, management of a company, which, according to the established and certified system of total quality, strives towards achieving of a better market position, faces the problem of quality cost measurement and determination. Management, above all,...

  15. Total - annual report 2005

    International Nuclear Information System (INIS)

    2006-01-01

    This annual report presents the activities and results of TOTAL S.A., french society on oil and gas. It deals with statistics, the managers, key information on financial data and risk factors, information on the Company, unresolved Staff Comments, employees, major Shareholders, consolidated statements, markets, security, financial risks, defaults dividend arrearages and delinquencies, controls and procedures, code of ethics and financial statements. (A.L.B.)

  16. Total aerosol effect

    OpenAIRE

    Lohmann, Ulrike; Rotstayn, Leon; Storelvmo, Trude; Jones, Andrew; Menon, Surabi; Quaas, Johannes; Ekman, Annica M. L.; Koch, Dorothy; Ruedy, Reto A.

    2015-01-01

    Uncertainties in aerosol radiative forcings, especially those associated with clouds, contribute to a large extent to uncertainties in the total anthropogenic forcing. The interaction of aerosols with clouds and radiation introduces feedbacks which can affect the rate of precipitation formation. In former assessments of aerosol radiative forcings, these effects have not been quantified. Also, with global aerosol-climate models simulating interactively aerosols and cloud microphysical prope...

  17. Total space in resolution

    Czech Academy of Sciences Publication Activity Database

    Bonacina, I.; Galesi, N.; Thapen, Neil

    2016-01-01

    Roč. 45, č. 5 (2016), s. 1894-1909 ISSN 0097-5397 R&D Projects: GA ČR GBP202/12/G061 EU Projects: European Commission(XE) 339691 - FEALORA Institutional support: RVO:67985840 Keywords : total space * resolution random CNFs * proof complexity Subject RIV: BA - General Mathematics Impact factor: 1.433, year: 2016 http://epubs.siam.org/doi/10.1137/15M1023269

  18. Total Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Rubio, B.; Gelletly, W.

    2007-01-01

    The problem of determining the distribution of beta decay strength (B(GT)) as a function of excitation energy in the daughter nucleus is discussed. Total Absorption Spectroscopy is shown to provide a way of determining the B(GT) precisely. A brief history of such measurements and a discussion of the advantages and disadvantages of this technique, is followed by examples of two recent studies using the technique. (authors)

  19. Comparative Study on Flexural Strengthening of RC Beams using CFRP Laminate by Different Techniques

    Science.gov (United States)

    Jeevan, N.; Jagannatha Reddy, H. N.

    2017-08-01

    This paper presents a detailed study on flexural behaviour of RC beams strengthened using Carbon Fiber Reinforced Polymer (CFRP) laminate. A detailed study was made on strengthened beam using Externally Bonded Laminate (EBL) and Internally Bonded Laminate (IBL) techniques. In IBL technique the laminate is sandwiched between the layers of epoxy mounted on the cover portion by the groove. The beams were designed as under-reinforced section. Totally six beams were casted, out of this two beams were control beams. Strengthened beams were divided into two sets (IBL and EBL) of two beams each. The main aim of this work is to delay the debonding failure in order to enhance the ultimate load carrying capacity for strengthened beams. Four-point bending flexural tests were conducted on specimens up to failure. The experimental results illustrate that, the strengthened beams significantly increases the cracking, working and ultimate load when compared with control beams. IBL technique shows the significant increase in the debonding strain by delaying the beam from debonding failure which in turn enhances the ultimate load by almost 73% compared with control beam and 39% with EBL technique. All the deflection values from the experiments are within the limit of codal provisions. The IBL technique was emerged as the better strengthening technique, which increases almost 41% of working load (Pw) compared with strengthening codes.

  20. HIV Prevention

    Centers for Disease Control (CDC) Podcasts

    2012-02-01

    Dr. Kevin Fenton, Director of CDC’s National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention, talks about steps people can take to protect their health from HIV.  Created: 2/1/2012 by National Center for HIV/AIDS, Viral Hepatitis, STD, and TB Prevention (NCHHSTP).   Date Released: 2/1/2012.

  1. Sobredentadura total superior implantosoportada

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.

  2. Beam-Material Interaction

    CERN Document Server

    Mokhov, N.V.

    2016-01-01

    Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high- intensity energetic particle beam interactions with accelerator, generic target , and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and envir onment in challenging current and future application

  3. Relativistic electron beam device

    Science.gov (United States)

    Freeman, J.R.; Poukey, J.W.; Shope, S.L.; Yonas, G.

    1975-07-01

    A design is given for an electron beam device for irradiating spherical hydrogen isotope bearing targets. The accelerator, which includes hollow cathodes facing each other, injects an anode plasma between the cathodes and produces an approximately 10 nanosecond, megajoule pulse between the anode plasma and the cathodes. Targets may be repetitively positioned within the plasma between the cathodes, and accelerator diode arrangement permits materials to survive operation in a fusion power source. (auth)

  4. Beam-Material Interaction

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N. V. [Fermilab; Cerutti, F. [CERN

    2016-01-01

    Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high-intensity energetic particle beam interactions with accelerator, generic target, and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and environment in challenging current and future applications.

  5. Stationary nonlinear Airy beams

    International Nuclear Information System (INIS)

    Lotti, A.; Faccio, D.; Couairon, A.; Papazoglou, D. G.; Panagiotopoulos, P.; Tzortzakis, S.; Abdollahpour, D.

    2011-01-01

    We demonstrate the existence of an additional class of stationary accelerating Airy wave forms that exist in the presence of third-order (Kerr) nonlinearity and nonlinear losses. Numerical simulations and experiments, in agreement with the analytical model, highlight how these stationary solutions sustain the nonlinear evolution of Airy beams. The generic nature of the Airy solution allows extension of these results to other settings, and a variety of applications are suggested.

  6. Lessons in beam diagnostics

    International Nuclear Information System (INIS)

    Jones, O.R.

    2012-01-01

    This paper will concentrate on the studies carried out on LHC beam instrumentation systems during the 2011 run, the improvements made and the outlook for 2012. It will include an update on the issues resolved since 2010, such as the performance of the BCT systems, and discuss advances in the bunch by bunch measurement capability of many systems. The paper will also highlight what can be hoped for in terms of performance for 2012 and the issues which remain to be solved. (author)

  7. Beam in on curing

    International Nuclear Information System (INIS)

    Holl, Dr.

    1981-01-01

    This third part of an article on the electron beam curing of paints covers the following aspects: inertising equipment; working without inert gas; increase in temperature when irradiating; irradiating plants; laboratory plants; plant operating from coil to coil; plant for shaped parts; possible applications; decorative films, paper, PVC; packaging material; metallisation of paper films; film bonding; strengthening of flock; coating; pressure sensitive adhesives. (U.K.)

  8. Design of the ITER Neutral Beam injectors

    International Nuclear Information System (INIS)

    Hemsworth, R.S.; Feist, J.; Hanada, M.; Heinemann, B.; Inoue, T.; Kuessel, E.; Kulygin, V.; Krylov, A.; Lotte, P.; Miyamoto, K.; Miyamoto, N.; Murdoch, D.; Nagase, A.; Ohara, Y.; Okumura, Y.; Pamela, J.; Panasenkov, A.; Shibata, K.; Tanii, M.

    1996-01-01

    This paper describes the Neutral Beam Injection system which is presently being designed in Europe, Japan and Russia, with co-ordination by the Joint Central Team of ITER at Naka, Japan. The proposed system consists of three negative ion based neutral injectors, delivering a total of 50 MW of 1 MeV D 0 to the ITER plasma for pulse length of ≥1000 s. The injectors each use a single caesiated volume arc discharge negative ion source, and a multi-grid, multi-aperture accelerator, to produce about 40 A of 1 MeV D - . This will be neutralized in a sub-divided gas neutralizer, which has a conversion efficiency of about 60%. The charged fraction of the beam emerging from the neutralizer is dumped in an electrostatic residual ion dump. A water cooled calorimeter can be moved into the beam path to intercept the neutral beam, allowing commissioning of the injector independent of ITER. copyright 1996 American Institute of Physics

  9. Beam screen issues

    CERN Document Server

    Métral, E

    2011-01-01

    In the High Energy LHC (HE-LHC), a beam energy of about 16.5 TeV is currently contemplated. The beam screen issues linked to the use of 20 T dipole magnets instead of 8.33 T are discussed, with a particular emphasis on two mechanisms, the magneto-resistance and the anomalous skin effect, assuming the nominal machine and beam parameters. The magneto-resistance effect always leads to an increase of the material resistivity (as the mean free path in the presence of a transverse magnetic field becomes smaller). As concerns the anomalous skin effect, the anomalous increase of surface resistance of metals at low temperatures and high frequencies is attributed to the long mean free path of the conduction electrons: when the skin depth becomes much smaller than the mean free path, only a fraction of the conduction electrons moving almost parallel to the metal surface is effective in carrying the current and the classical theory breaks down.

  10. The beam transport system

    International Nuclear Information System (INIS)

    1986-01-01

    The first proton beams have been transported along the transfer beamline and the diagnostic components have thus been used and tested under real operating conditions. The various electronic systems have been linked to the control system and the equipment can now be operated from the control console. The performance of the diagnostic system for the transfer beamline is satisfactory. The beam diagnostic components for the high-energy beamlines up to the isotope production and neutron therapy vaults and the first experimental target rooms have been installed. The high-energy slits have been delivered. The scanner and harp electronics have been installed and linked to their respective components in the beamlines. The pneumatic acuator control electronics has been manufactured, installed and is operational; provision has been made for special control features of the equipment in the therapy beamline. The high-voltage bias supply for the Faraday cups has been implemented. The installation of the beam current measurement system is nearing completion although part of it is already operational. A coaxial relay multiplexer for the capacitive phase probe signals has been manufactured and installed. The diagnostic equipment for the beamlines to isotope production and neutron therapy is thus ready for operation. 4 figs

  11. Hyperon Beam Experiment

    CERN Multimedia

    2002-01-01

    The experiment WA89 uses the upgraded Omega facility together with a hyperon beam installed at the end of the H1 beamline. The beam can deliver 2~10$ ^{5} \\% Sigma ^- $ per machine burst at 330 GeV/c with a background of 5 10$ ^{5} \\% \\pi ^- $. \\\\ \\\\ The goals of the experiment are: observation of charmed particles, mainly the charmed-strange baryons and measurements of their production in the kinematical range x$ _{F} $~$>$~0.2, and their decay properties, a search for exotic states such as U(3100) observed in the previous CERN hyperon beam experiment WA62, measurements of hyperon polarization and production properties. \\\\ \\\\ A vertex detector consisting of 24 silicon microstrip planes with 25~$\\mu$m pitch and 6~planes with 50~$\\mu$m pitch provides track measurements of sufficient accuracy to identify the decays of short living charmed particles and measure their lifetimes. A RICH detector provides good $\\pi$/K separation for momenta up to 100~GeV/c and $\\pi$/p separation up to 150~GeV/c. Photons are detecte...

  12. Fixed target beams

    CERN Document Server

    Kain, V; Cettour-Cave, S; Cornelis, K; Fraser, M A; Gatignon, L; Goddard, B; Velotti, F

    2017-01-01

    The CERN SPS (Super Proton Synchrotron) serves asLHC injector and provides beam for the North Area fixedtarget experiments. At low energy, the vertical acceptancebecomes critical with high intensity large emittance fixed tar-get beams. Optimizing the vertical available aperture is a keyingredient to optimize transmission and reduce activationaround the ring. During the 2016 run a tool was developed toprovide an automated local aperture scan around the entirering.The flux of particles slow extracted with the1/3inte-ger resonance from the Super Proton Synchrotron at CERNshould ideally be constant over the length of the extractionplateau, for optimum use of the beam by the fixed target ex-periments in the North Area. The extracted intensity is con-trolled in feed-forward correction of the horizontal tune viathe main SPS quadrupoles. The Mains power supply noiseat 50 Hz and harmonics is also corrected in feed-forwardby small amplitude tune modulation at the respective fre-quencies with a dedicated additional quad...

  13. Particle beams and plasmas

    International Nuclear Information System (INIS)

    Hofmann, A.; Messerschmid, E.; Lawson, J.D.

    1976-01-01

    These lectures present a survey of some of the concepts of plasma physics and look at some situations familiar to particle-accelerator physicists from the point of view of a plasma physicist, with the intention of helping to link together the two fields. At the outset, basic plasma concepts are presented, including definitions of a plasma, characteristic parameters, magnetic pressure and confinement. This is followed by a brief discussion on plasma kinetic theory, non-equilibrium plasma, and the temperature of moving plasmas. Examples deal with beams in the CERN Intersecting Storage Rings as well as with non-steady beams in cyclic accelerators and microwave tubes. In the final chapters, time-varying systems are considered: waves in free space and the effect of cylinder bounds, wave motion in cold stationary plasmas, and waves in plasmas with well-defined streams. The treatment throughout is informal, with emphasis on the essential physical properties of continuous beams in accelerators and storage rings in relation to the corresponding problems in plasma physics and microwave tubes. (Author)

  14. Linac design for intense hadron beams

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chuan

    2009-12-14

    Based on the RFQ and H-type DTL structures, this dissertation is dedicated to study the beam dynamics in the presence of significantly strong space-charge effects while accelerating intense hadron beams in the low- and medium-{beta} region. Besides the 5 mA/30 mA, 17 MeV proton injector (RFQ+DTL) and the 125 mA, 40 MeV deuteron DTL of the EUROTRANS and IFMIF facilities, a 200 mA, 700 keV proton RFQ has been also intensively studied for a small-scale but ultra-intense neutron source FRANZ planned at Frankfurt University. The most remarkable properties of the FRANZ RFQ and the IFMIF DTL are the design beam intensities, 200 mA and 125 mA. A new design approach, which can provide a balanced and accelerated beam bunching at low energy, has been developed for intense beams. To design the IFMIF DTL and the injector DTL part of the EUROTRANS driver linac, which have been foreseen as the first real applications of the novel superconducting CH-DTL structure, intensive attempts have been made to fulfill the design goals under the new conditions. For the IFMIF DTL, the preliminary IAP design has been considerably improved with respect to the linac layout as well as the beam dynamics. By reserving sufficient drift spaces for the cryosystem, diagnostic devices, tuner and steerer, introducing SC solenoid lenses and adjusting the accelerating gradients and accordingly other configurations of the cavities, a more realistic, reliable and efficient linac system has been designed. On the other hand, the specifications and positions of the transverse focusing elements as well as the phase- and energy-differences between the bunch-center particle and the synchronous particle at the beginning of the {phi}{sub s}=0 sections have been totally redesigned. For the EUROTRANS injector DTL, in addition to the above-mentioned procedures, extra optimization concepts to coordinate the beam dynamics between two intensities have been applied. In the beam transport simulations for both DTL designs

  15. Experimental Study on RC Beams Strengthened with Carbon and Glass Fiber Sheets

    Directory of Open Access Journals (Sweden)

    Thaksin Thepchatri

    2009-05-01

    Full Text Available This study investigates the effects of the two types of fiber sheets, namely, carbon and glass fiber sheets, on the flexural behaviors of reinforced concrete (RC beams when they are bonded to the tension zones of the beams. A total of eight full-scale beams were tested in the experiments. The flexural strength and stiffness of RC beams were found to increase significantly after the installation of fiber sheets. An analytical model based on the principle of virtual work was developed to predict the load-deflection relationship of the hybrid beams. The paper also highlights the characteristics of debonding problem which limits the effective use of fiber materials.

  16. Angular scattering in electron capture and loss D- beam formation processes

    International Nuclear Information System (INIS)

    Coggiola, M.J.; Hodges, R.V.; Huestis, D.L.; Peterson, J.R.

    1980-01-01

    The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken

  17. Premature beam dumps in 2011

    CERN Document Server

    Albert, Markus

    2012-01-01

    The statistical analysis of all non-programmed beam dumps during the 2011 proton run is presented. The selection criteria of fills that got considered were that the beam intensity of each of the two beams exceeded at least 1e12 particles per beam in order to exclude all probe beam dumps and most of the MPS test dumps. A distribution of beam dump causes by system is shown, as well as the time it took to re-establish injection after a non-programmed dump for fills which made it into STABLE BEAMS. This was done in an attempt to evaluate the cost of those non-programmed dumps in terms of time.

  18. CLIC Drive Beam Phase Stabilisation

    CERN Document Server

    Gerbershagen, Alexander; Schulte, Daniel

    The thesis presents phase stability studies for the Compact Linear Collider (CLIC) and focuses in particular on CLIC Drive Beam longitudinal phase stabilisation. This topic constitutes one of the main feasibility challenges for CLIC construction and is an essential component of the current CLIC stabilisation campaign. The studies are divided into two large interrelated sections: the simulation studies for the CLIC Drive Beam stability, and measurements, data analysis and simulations of the CLIC Test Facility (CTF3) Drive Beam phase errors. A dedicated software tool has been developed for a step-by-step analysis of the error propagation through the CLIC Drive Beam. It uses realistic RF potential and beam loading amplitude functions for the Drive and Main Beam accelerating structures, complete models of the recombination scheme and compressor chicane as well as of further CLIC Drive Beam modules. The tool has been tested extensively and its functionality has been verified. The phase error propagation at CLIC h...

  19. Ion beam generation and focusing

    International Nuclear Information System (INIS)

    Miller, P.A.; Mendel, C.W.; Swain, D.W.; Goldstein, S.A.

    1975-01-01

    Calculations have shown that efficiently generated and focused ion beams could have significant advantages over electron beams in achieving ignition of inertially-confined thermonuclear fuel. Efficient ion beam generation implies use of a good ion source and suppression of net electron current. Net electron flow can be reduced by allowing electrons to reflex through a highly transparent anode or by use of transverse magnetic fields (either beam self-fields or externally applied fields). Geometric focusing can be achieved if the beam is generated by appropriately shaped electrodes. Experimental results are presented which demonstrate ion beam generation in both reflexing and pinched-flow diodes. Spherically shaped electrodes are used to concentrate a proton beam, and target response to proton deposition is studied

  20. Operational beams for the LHC

    CERN Document Server

    Papaphilippou, Y.; Rumolo, G.; Manglunki, D.

    2014-01-01

    The variety of beams, needed to set-up in the injectors as requested in the LHC, are reviewed, in terms of priority but also performance expectations and reach during 2015. This includes the single bunch beams for machine commissioning and measurements (probe, Indiv) but also the standard physics beams with 50 ns and 25 ns bunch spacing and their high brightness variants using the Bunch Compression Merging and Splitting (BCMS) scheme. The required parameters and target performance of special beams like the doublet for electron cloud enhancement and the more exotic 8b$\\oplus$4e beam, compatible with some post-scrubbing scenarios are also described. The progress and plans for the LHC ion production beams during 2014-2015 are detailed. Highlights on the current progress of the setting up of the various beams are finally presented with special emphasis on potential performance issues across the proton and ion injector chain.