WorldWideScience

Sample records for prevent gas leakage

  1. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  2. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  3. Design and Development of Gas Leakage Monitoring System Using Arduino and ZigBee

    OpenAIRE

    Yan, Huan Hui; Rahayu, Yusnita

    2014-01-01

    Gas leakage in industrial area causes many health issues. Thus, to prevent such disasters happen, the atmosphere of a workplace should be regularly monitored and controlled, in order to maintain the clean air environment. However, efforts in industrial air quality control have been impeded by the lack of science-based approaches to identify and assess atmosphere air quality and level of dangerous gas. Therefore, a monitoring system for gas leakage detection needs to be developed. For the deve...

  4. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  5. Early detection of LPG gas leakage based Wireless Sensor Networking

    Directory of Open Access Journals (Sweden)

    Kusriyanto Medilla

    2018-01-01

    Full Text Available LPG gas is the main fuel used in households. These days LPG gas leak triggered an accident that resulted in huge losses, especially if the accident occurred within the dense housing. LPG gas leakage monitoring and early detection of a gas leak and a leak warning is needed to prevent more fatal accident. Wireless sensor networking is a technology that can be used to build a centralized monitoring system by using a microcontroller as the interface and control system. This research developed system device monitoring and early detection of gas leaks by utilizing gas sensors MQ-4 and AVR microcontroller family as control devices. The system is also equipped with XBee PRO S2B nirkable devices as the interface to the wireless networking system that is used to transmit sensor data from the detection point to the monitoring center equipped with a PC and software integrated Visual Basic. Gas leak alert is sent with the message formats through social networking Gtalk.

  6. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  7. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  8. Small gas leakage rate measuring and monitoring system for spent fuel transport/storage cask

    Energy Technology Data Exchange (ETDEWEB)

    Asano, Ryoji [Hitachi Zosen Corp., Tokyo (Japan); Aritomi, Masanori; Matsuzaki, Mitsuo; Kawa, Tsunemichi

    1997-12-01

    A containment function of transport and/or storage casks of radioactive materials is essential to prevent the materials from being released excessively into the environment. It is not practical for containment tests to measure directly the radioactivity release so that gas volumetric leakage rates are usually assessed and gas pressure decrease or increase method is usually applied. As gas flow model for evaluation, the ISO standards has deleted the concept of choked flow which is adopted by ANSI N14.5. Provided that the choked flow is not adopted to the leakage rate evaluation, the criteria of the test should be severe, and a new leakage rate measuring system with high accuracy and reasonable measuring time is required. Transport casks are often inspected in a temporary cask-storage facility where simultaneous measurement of many casks is required. In a storage cask system, multiple casks are monitored on their containment function during a storage period, and the method for simultaneous monitoring at many points for long term is required. In this study, two kinds of small gas leakage rate measuring systems are developed. One is to measure gas leakage rates directly and is called `flow measuring system`, which can measure gas leakage rate of 10{sup -4} to 10{sup -2} cm{sup 3}/s with high accuracy and short measuring time. The other is to measure the pressure decreasing rate and is called `pressure decreasing rate measuring system`, which can monitor the pressure change at many points simultaneously. (author)

  9. Thermogenic Wet Gas in Immature Caprock Sections: Leakage or Generation.

    Science.gov (United States)

    Abrakasa, Selegha; Beka, Francis; Ndukauba, Egesi

    2017-04-01

    Gas geochemistry, an aspect of Petroleum Geoscience is a growing science, various concepts has been used to evaluation potential source rock for shale gas while in conventional petroleum exploration similar concepts have been used to determine potential productive formation for liquid hydrocarbons. Prior to the present times, headspace gas data had been used to recognize by pass pays, serve as indicators of petroleum accumulations, evaluate maturity and productive capacity of corresponding formations, evaluate the maturity and source of gas accumulations. Integrating studies in bid to achieve high degree of accuracy, data on direct hydrocarbon indicators (DHIs) such as oil stains, oil shows and seeps have been employed. Currently popular among professionals is the use of gas clouds on seismic cross sections. In contemporary times, advancement in gas geochemistry has witnessed the application of concepts on headspace gas to expound the efficiency of petroleum caprocks whose major role is to foster accumulation and preservation. This enables extricating potential leakage mechanism via caprock reservoir interface and unravel its corresponding migrational pathways. In this study thermogenic wet gas has been used as a dependable tool for delineating caprock leakage by discriminating migrant from indigenous hydrocarbons in caprock rock sections overlying the reservoirs. The thermogenic gas profile in corroboration with the thermogenic signature and maturity data were used. Summary statistics indicates that 60% of the 50 wells studied has wet gas up to 500m above the reservoir-caprock interface and 10% of the leaking wells are fracture prone leakage.The amount of wet gas ranges of up to 200,000 ppm in the caprock sections, this indicates pervasive leakage. Log view plots were modelled using Schlumbergers' Techlog, while descriptive lithologies were modeled using Zetawares' genesis.

  10. Greater focus needed on methane leakage from natural gas infrastructure.

    Science.gov (United States)

    Alvarez, Ramón A; Pacala, Stephen W; Winebrake, James J; Chameides, William L; Hamburg, Steven P

    2012-04-24

    Natural gas is seen by many as the future of American energy: a fuel that can provide energy independence and reduce greenhouse gas emissions in the process. However, there has also been confusion about the climate implications of increased use of natural gas for electric power and transportation. We propose and illustrate the use of technology warming potentials as a robust and transparent way to compare the cumulative radiative forcing created by alternative technologies fueled by natural gas and oil or coal by using the best available estimates of greenhouse gas emissions from each fuel cycle (i.e., production, transportation and use). We find that a shift to compressed natural gas vehicles from gasoline or diesel vehicles leads to greater radiative forcing of the climate for 80 or 280 yr, respectively, before beginning to produce benefits. Compressed natural gas vehicles could produce climate benefits on all time frames if the well-to-wheels CH(4) leakage were capped at a level 45-70% below current estimates. By contrast, using natural gas instead of coal for electric power plants can reduce radiative forcing immediately, and reducing CH(4) losses from the production and transportation of natural gas would produce even greater benefits. There is a need for the natural gas industry and science community to help obtain better emissions data and for increased efforts to reduce methane leakage in order to minimize the climate footprint of natural gas.

  11. Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

    Science.gov (United States)

    Teverovsky, Alexander

    2015-01-01

    Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

  12. [A mobile sensor for remote detection of natural gas leakage].

    Science.gov (United States)

    Zhang, Shuai; Liu, Wen-qing; Zhang, Yu-jun; Kan, Rui-feng; Ruan, Jun; Wang, Li-ming; Yu, Dian-qiang; Dong, Jin-ting; Han, Xiao-lei; Cui, Yi-ben; Liu, Jian-guo

    2012-02-01

    The detection of natural gas pipeline leak becomes a significant issue for body security, environmental protection and security of state property. However, the leak detection is difficult, because of the pipeline's covering many areas, operating conditions and complicated environment. A mobile sensor for remote detection of natural gas leakage based on scanning wavelength differential absorption spectroscopy (SWDAS) is introduced. The improved soft threshold wavelet denoising was proposed by analyzing the characteristics of reflection spectrum. And the results showed that the signal to noise ratio (SNR) was increased three times. When light intensity is 530 nA, the minimum remote sensitivity will be 80 ppm x m. A widely used SWDAS can make quantitative remote sensing of natural gas leak and locate the leak source precisely in a faster, safer and more intelligent way.

  13. Evaluation method of gas leakage rate from transportation casks of radioactive materials (gas leakage rates from scratches on O-ring surface)

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Li Ninghua; Asano, Ryoji; Kawa, Tsunemichi

    2004-01-01

    A sealing function is essential for transportation and/or storage casks of radioactive materials under both normal and accidental operating conditions in order to prevent radioactive materials from being released into the environment. In the safety analysis report, the release rate of radioactive materials into the environment is evaluated using the correlations specified in the ANSI N14.5, 1987. The purposes of the work are to reveal the underlying problems on the correlations specified in the ANSI N14.5 related to gas leakage rates from a scratch on O-ring surface and from multi-leak paths, to offer a data base to study the evaluation method of the leakage rate and to propose the evaluation method. In this paper, the following insights were obtained and clarified: 1. If a characteristic value of a leak path is defined as D 4 /a ('D' is the diameter and 'a' is the length), a scratch on the O-ring surface can be evaluated as a circular tube. 2. It is proper to use the width of O-ring groove on the flange as the leak path length for elastomer O-rings. 3. Gas leakage rates from multi leak paths of the transportation cask can be evaluated in the same manner as a single leak path if an effective D4/a is introduced. (author)

  14. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  15. Model-based Estimation of Gas Leakage for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Pedersen, Henrik Clemmensen; N. Soltani, Mohsen

    2017-01-01

    for accumulators, namely gas leakage. The method utilizes an Extended Kalman Filter for joint state and parameter estimation with special attention to limiting the use of sensors to those commonly used in wind turbines. The precision of the method is investigated on an experimental setup which allows for operation...... of the accumulator similar to the conditions in a turbine. The results show that gas leakage is indeed detectable during start-up of the turbine and robust behavior is achieved in a multi-fault environment where both gas and external fluid leakage occur simultaneously. The estimation precision is shown...... to be sensitive to initial conditions for the gas temperature and volume....

  16. Long-term monitoring of marine gas leakage

    Science.gov (United States)

    Spickenbom, Kai; Faber, Eckhard; Poggenburg, Jürgen; Seeger, Christian; Furche, Markus

    2010-05-01

    The sequestration of CO2 in sub-seabed geological formations is one of the Carbon Capture and Storage (CCS) strategies currently under study. Although offshore operations are significantly more expensive than comparable onshore operations, the growing public resistance against onshore CCS projects makes sub-seabed storage a promising option. Even after a thorough review of the geological setting, there is always the possibility of leakage from the reservoir. As part of the EU-financed project CO2ReMoVe (Research, Monitoring, Verification), which aims to develop innovative research and technologies for monitoring and verification of carbon dioxide geological storage, we are working on the development of submarine long-term gas flow monitoring systems. The basic design of the monitoring system builds on our experience in volcano monitoring. Early prototypes were composed of a raft floating on the surface of a mud volcano, carrying sensors for CO2 flux and concentration, data storage and transmission, and power supply by battery-buffered solar panels. The system was modified for installation in open sea by using a buoy instead of a raft and a funnel on the seafloor to collect the gas, connected by a flexible tube. This setup provides a cost-effective solution for shallow waters. However, a buoy interferes with ship traffic, and it is also difficult to adapt this design to greater water depths. These requirements can best be complied by a completely submersed system. A system for unattended long-term monitoring in a marine environment has to be extremely durable. Therefore, we focussed on developing a mechanically and electrically as simple setup as possible, which has the additional advantage of low cost. The system consists of a funnel-shaped gas collector, a sensor head and pressure housings for electronics and power supply. Since this setup is inexpensive, it can be deployed in numbers to cover larger areas. By addition of multi-channel data loggers, data

  17. Financial Risk Factor Analysis for Facility Gas Leakages of H2 and NG

    Directory of Open Access Journals (Sweden)

    In-Bok Lee

    2016-09-01

    Full Text Available Fuel cells may be the key to a more environmentally-friendly future because they emit low carbon dioxide per unit of energy supplied. However, little work has investigated the potential financial risks pertaining to fuel cell systems. Often used in the analysis of the safety of systems involving flammable or hazardous materials, risk factor analysis has recently been used to analyze the potential financial losses that may occur from industrial hazards. Therefore, this work undertakes a financial risk factor analysis to determine the costs of leakages of hydrogen and natural gas, which are used in fuel cell systems. Total leakage was calculated from an analysis of several leakage rates and modes. The impact of applying appropriate detection and prevention systems was also investigated. The findings were then used to analyze the consequences for various sections of the system and to calculate the overall cost based on facility outage or damage, and the cost of taking safety precautions. This provides a basis for comparison among proposed potential reactionary measures.

  18. Signal-based Gas Leakage Detection for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Sepehri, Nariman; N. Soltani, Mohsen

    2017-01-01

    This paper describes the development and application of a signal-based fault detection method for identifying gas leakage in hydraulic accumulators used in wind turbines. The method uses Multiresolution Signal Decomposition (MSD) based on wavelets for feature extraction from a~single fluid pressure...... measurement located close to the accumulator. Gas leakage is shown to create increased variations in this pressure signal. The Root Mean Square (RMS) of the detail coefficient Level 9 from the MSD is found as the most sensitive and robust fault indicator of gas leakage. The method is verified...

  19. Comparing Natural Gas Leakage Detection Technologies Using an Open-Source "Virtual Gas Field" Simulator.

    Science.gov (United States)

    Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R

    2016-04-19

    We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.

  20. Quantum error prevention and leakage elimination for quantum dots

    Science.gov (United States)

    Pegahan, Saeed; Byrd, Mark S.; Reddy Chinni, Karthik

    2015-03-01

    Decoherence-free, or noiseless subsystems, are used to encode spin qubits in quantum dots in order to achieve universal quantum computing using only the exchange interaction. We investigate the use of dynamical decoupling controls for the purposes of eliminating leakage for a logical qubit encoded using three physical qubits. These leakage elimination operators (LEOs) can be used to eliminate all leakage errors using exchange interactions between the physical spin qubits. Depending on the encoding and the decoupling control, different types of errors can be eliminated. We show several different possible controls and the consequential noise reduction for different encodings as well as our general method for determining the effectiveness of these pulses.

  1. Numerical Modeling of Methane Leakage from a Faulty Natural Gas Well into Fractured Tight Formations.

    Science.gov (United States)

    Moortgat, Joachim; Schwartz, Franklin W; Darrah, Thomas H

    2018-03-01

    Horizontal drilling and hydraulic fracturing have enabled hydrocarbon recovery from unconventional reservoirs, but led to natural gas contamination of shallow groundwaters. We describe and apply numerical models of gas-phase migration associated with leaking natural gas wells. Three leakage scenarios are simulated: (1) high-pressure natural gas pulse released into a fractured aquifer; (2) continuous slow leakage into a tilted fractured formation; and (3) continuous slow leakage into an unfractured aquifer with fluvial channels, to facilitate a generalized evaluation of natural gas transport from faulty natural gas wells. High-pressure pulses of gas leakage into sparsely fractured media are needed to produce the extensive and rapid lateral spreading of free gas previously observed in field studies. Transport in fractures explains how methane can travel vastly different distances and directions laterally away from a leaking well, which leads to variable levels of methane contamination in nearby groundwater wells. Lower rates of methane leakage (≤1 Mcf/day) produce shorter length scales of gas transport than determined by the high-pressure scenario or field studies, unless aquifers have low vertical permeabilities (≤1 millidarcy) and fractures and bedding planes have sufficient tilt (∼10°) to allow a lateral buoyancy component. Similarly, in fractured rock aquifers or where permeability is controlled by channelized fluvial deposits, lateral flow is not sufficiently developed to explain fast-developing gas contamination (0-3 months) or large length scales (∼1 km) documented in field studies. Thus, current efforts to evaluate the frequency, mechanism, and impacts of natural gas leakage from faulty natural gas wells likely underestimate contributions from small-volume, low-pressure leakage events. © 2018, National Ground Water Association.

  2. Risk Analysis on Leakage Failure of Natural Gas Pipelines by Fuzzy Bayesian Network with a Bow-Tie Model

    Directory of Open Access Journals (Sweden)

    Xian Shan

    2017-01-01

    Full Text Available Pipeline is the major mode of natural gas transportation. Leakage of natural gas pipelines may cause explosions and fires, resulting in casualties, environmental damage, and material loss. Efficient risk analysis is of great significance for preventing and mitigating such potential accidents. The objective of this study is to present a practical risk assessment method based on Bow-tie model and Bayesian network for risk analysis of natural gas pipeline leakage. Firstly, identify the potential risk factors and consequences of the failure. Then construct the Bow-tie model, use the quantitative analysis of Bayesian network to find the weak links in the system, and make a prediction of the control measures to reduce the rate of the accident. In order to deal with the uncertainty existing in the determination of the probability of basic events, fuzzy logic method is used. Results of a case study show that the most likely causes of natural gas pipeline leakage occurrence are parties ignore signage, implicit signage, overload, and design defect of auxiliaries. Once the leakage occurs, it is most likely to result in fire and explosion. Corresponding measures taken on time will reduce the disaster degree of accidents to the least extent.

  3. Magnetic shaft seals prevent hazardous leakage from wastewater agitators

    International Nuclear Information System (INIS)

    Traino, F.A.

    1985-01-01

    The US Department of Energy's laboratory in Miamisburg, OH, operated by Monsanto Research Corporation, processes approximately 45,000 gallons per week of low-level radioactive wastewater to meet Federal Environmental Protection Agency quality standards. Preventing the spread of radioactive contamination throughout the operating area demands effective sealing of all process piping, valves, pumps, and agitators. Rotating shafts of pumps and agitators installed a the start of operations in 1947 were sealed by stuffing glands with graphite impregnated asbestos packing. These pumps proved to be unsatisfactory. In the mid-1970's, new process pumps with mechanical seals and some with magnetic drives were installed. Later, in January 1979, new agitator shaft drives with double tandem, spring-loaded mechanical seals were installed, maintenance of these pumps was costly. The agitator drive shafts were redesigned to accommodate magnetic seals of the type successfully used in blowers and vacuum/pressure pumps in other plant locations. One inherent advantage of the magnetic seal is that it operates with a face loading as much as 50% less than a conventional spring-loaded mechanical seal. The lower loading by a predetermined uniform magnetic force contributes to long face life. Other advantages include compactness, ease of assembly with only a few parts, and insensitivity to vibration. The magnetic shaft seals installed on the agitator shafts in February 1983 are still in service without any leakage or need for maintenance. Based on current operating data and a projected five-year meantime between failures, the estimated cost benefit of the magnetic seals over spring-loaded mechanical seals over spring-loaded mechanical seals will be $640 vs $2400 respectively per seal, with 60% less downtime for maintenance

  4. Urban Leakage of Liquefied Petroleum Gas and Its Impact on Mexico City Air Quality

    Science.gov (United States)

    Blake, Donald R.; Sherwood Rowland, F.

    1995-08-01

    Alkane hydrocarbons (propane, isobutane, and n-butane) from liquefied petroleum gas (LPG) are present in major quantities throughout Mexico City air because of leakage of the unburned gas from numerous urban sources. These hydrocarbons, together with olefinic minor LPG components, furnish substantial amounts of hydroxyl radical reactivity, a major precursor to formation of the ozone component of urban smog. The combined processes of unburned leakage and incomplete combustion of LPG play a significant role in causing the excessive ozone characteristic of Mexico City. Reductions in ozone levels should be possible through changes in LPG composition and lowered rates of leakage.

  5. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  6. Prevention of leakage of low-melting-point metals from styrofoam molds.

    Science.gov (United States)

    Herman, M W; Robinson, A; Small, R C

    1975-10-01

    Leakage of low-melting-point metals from the underside of polystyrene molds can be prevented by applying a silicone caulking material to the bottom of the mold and pressing the mold on a metal plate before pouring.

  7. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario

    Directory of Open Access Journals (Sweden)

    Jing Ma

    2017-11-01

    Full Text Available The technology of carbon dioxide (CO2 capture and storage (CCS has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO2 geological storage was designed to investigate the short-term effects of different CO2 leakage concentration (from 400 g m−2 day−1 to 2,000 g m−2 day−1 on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO2 concentrations. Increasing CO2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 (p < 0.05. Nitrate nitrogen content varied from 1.01 to 4.03 mg/Kg, while Olsen-phosphorus and total phosphorus demonstrated less regular downtrends. The fluorescein diacetate (FDA hydrolytic enzyme activity was inhibited by the increasing CO2 flux, with the average content varying from 22.69 to 11.25 mg/(Kg h (p < 0.05. However, the increasing activity amplitude of the polyphenol oxidase enzyme approached 230%, while the urease activity presented a similar rising trend. Alpha diversity results showed that the Shannon index decreased from 7.66 ± 0.13 to 5.23 ± 0.35 as the soil CO2 concentration increased. The dominant phylum in the soil samples was Proteobacteria, whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% (p < 0.01. Moreover, the abundances of genera Methylophilus, Methylobacillus, and Methylovorus increased, while GP4, GP6 and GP7 decreased. Canonical correlation analysis

  8. Assessment of leakage at the implant-abutment connection using a new gas flow method.

    Science.gov (United States)

    Fauroux, Marie-Alix; Levallois, Bernard; Yachouh, Jacques; Torres, Jacques-Henri

    2012-01-01

    The aim of this study was to evaluate, with a new gas flow technique, leakage at the implant/abutment junction in systems with four different connections. Five Branemark System, five One Morse, five Intra-lock System, and five Ankylos Plus implants and abutments were used. A hole was drilled in the apex of each implant to allow gas to flow through the connection from negative to atmospheric pressure. The gas flow was calculated (slope of pressure decrease, in hPa.s-1). Each connection was tested after both manual and key tightening. Statistical analysis was performed on a generalized linear model with repeated measurements. The significance level was set at α=.05. A global significant difference was observed between the various systems (P=.0001). After manual tightening, gas leakage was (Ln[hPa.s-1], means±standard deviations): One Morse: 0.20 (±1.70); Branemark System: -4.56 (±2.61); Intra-lock: -4.31 (±4.17); Ankylos Plus; -7.59 (±0.76). After key tightening, mean values were: One Morse: -2.51 (±2.72); Branemark System: -7.23 (±1.01); Intra-lock: -7.76 (±0.50); Ankylos Plus; -7.73 (±0.62). This study confirms that gas flow is an appropriate method to assess connection leakage. Ankylos Plus connection leakage was very low when the assembly was tightened manually. Among conical connection systems, low (Ankylos Plus) and high (One Morse) leakage was observed. This gas flow study suggests, therefore, that connection design is not the most important parameter for implant/abutment connection leakage.

  9. Data Leakage Prevention: E-Mail Protection via Gateway

    Science.gov (United States)

    Kaur, Kamaljeet; Gupta, Ishu; Singh, Ashutosh Kumar

    2018-01-01

    Protection of digital assets and intellectual property is becoming a challenge for most of the companies. Due to increasing availability of database services on internet, data may be insecure after passing through precarious networks. To protect intellectual property (IP) is a major concern for today's organizations, because a leakage that compromises IP means, sensitive information of a company is in the hands of biggest competitors. Electronic information processing and communication is replacing paper in many applications increasingly. Instead of paper, an email is being used for communication at workplace and from social media logins to bank accounts. Nowadays an email is becoming a mainstream business tool. An email can be misused to leave company’s sensitive data open to compromise. So, it may be of little surprise that attacks on emails are common. So, here we need an email protection system (EPS) that will protect information to leave organization via mail. In this paper, we developed an algorithm that will offer email protection via gateway during data transfer. This algorithm matches the patterns with the keywords stored in the database and then takes the actions accordingly to protect the data. This paper describes why email protection is important? How companies can protect their confidential information from being leaked by insiders.

  10. Fuzzy Bayesian Network-Bow-Tie Analysis of Gas Leakage during Biomass Gasification.

    Directory of Open Access Journals (Sweden)

    Fang Yan

    Full Text Available Biomass gasification technology has been rapidly developed recently. But fire and poisoning accidents caused by gas leakage restrict the development and promotion of biomass gasification. Therefore, probabilistic safety assessment (PSA is necessary for biomass gasification system. Subsequently, Bayesian network-bow-tie (BN-bow-tie analysis was proposed by mapping bow-tie analysis into Bayesian network (BN. Causes of gas leakage and the accidents triggered by gas leakage can be obtained by bow-tie analysis, and BN was used to confirm the critical nodes of accidents by introducing corresponding three importance measures. Meanwhile, certain occurrence probability of failure was needed in PSA. In view of the insufficient failure data of biomass gasification, the occurrence probability of failure which cannot be obtained from standard reliability data sources was confirmed by fuzzy methods based on expert judgment. An improved approach considered expert weighting to aggregate fuzzy numbers included triangular and trapezoidal numbers was proposed, and the occurrence probability of failure was obtained. Finally, safety measures were indicated based on the obtained critical nodes. The theoretical occurrence probabilities in one year of gas leakage and the accidents caused by it were reduced to 1/10.3 of the original values by these safety measures.

  11. Fuzzy Bayesian Network-Bow-Tie Analysis of Gas Leakage during Biomass Gasification.

    Science.gov (United States)

    Yan, Fang; Xu, Kaili; Yao, Xiwen; Li, Yang

    2016-01-01

    Biomass gasification technology has been rapidly developed recently. But fire and poisoning accidents caused by gas leakage restrict the development and promotion of biomass gasification. Therefore, probabilistic safety assessment (PSA) is necessary for biomass gasification system. Subsequently, Bayesian network-bow-tie (BN-bow-tie) analysis was proposed by mapping bow-tie analysis into Bayesian network (BN). Causes of gas leakage and the accidents triggered by gas leakage can be obtained by bow-tie analysis, and BN was used to confirm the critical nodes of accidents by introducing corresponding three importance measures. Meanwhile, certain occurrence probability of failure was needed in PSA. In view of the insufficient failure data of biomass gasification, the occurrence probability of failure which cannot be obtained from standard reliability data sources was confirmed by fuzzy methods based on expert judgment. An improved approach considered expert weighting to aggregate fuzzy numbers included triangular and trapezoidal numbers was proposed, and the occurrence probability of failure was obtained. Finally, safety measures were indicated based on the obtained critical nodes. The theoretical occurrence probabilities in one year of gas leakage and the accidents caused by it were reduced to 1/10.3 of the original values by these safety measures.

  12. Simple methods for predicting gas leakage flows through cracks

    International Nuclear Information System (INIS)

    Ewing, D.J.F.

    1989-01-01

    This report presents closed-form approximate analytical formulae with which the flow rate out of a through-wall crack can be estimated. The crack is idealised as a rough, tapering, wedgeshaped channel and the fluid is idealised as an isothermal or polytropically-expanding perfect gas. In practice, uncertainties about the wall friction factor dominate over uncertainties caused by the fluid-dynamics simplifications. The formulae take account of crack taper and for outwardly-diverging cracks they predict flows within 12% of mathematically more accurate one-dimensional numerical models. Upper and lower estimates of wall friction are discussed. (author)

  13. Recommended method to prevent leakage of titanium tube in condenser

    International Nuclear Information System (INIS)

    Wang Jun

    2010-01-01

    Qinshan Phase III is located at the estuary area of Qiantang River, where contains much slit and sand in the seawater. Since the units were put into operation, tube bundles in the condenser have been scratched, damaged or blocked by hard foreign materials, and outside wall thickness reduced and broken due to various reasons. Many tube bundles are discarded. In order to effectively prevent the re-occurrence of such problem and eliminate the existing defects, equipment management personnels of Qinshan Phase III work together with experts both from home and abroad, and perfom root-analysis for various cause of defects. After the problem root is identified, a serious of specific and effective measures are taken to prevent and eliminate the problem and reached a good effect. This paper herein is written for comments and reference. (authors)

  14. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.

    Science.gov (United States)

    Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J

    2014-01-01

    The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in

  15. Acute respiratory symptoms and evacuation-related behavior after exposure to chlorine gas leakage.

    Science.gov (United States)

    Han, Sung-Woo; Choi, Won-Jun; Yi, Min-Kee; Song, Seng-Ho; Lee, Dong-Hoon; Han, Sang-Hwan

    2016-01-01

    A study was performed on the accidental chlorine gas leakage that occurred in a factory of printed circuit boards manufactured without chlorine. Health examination was performed for all 52 workers suspected of exposure to chlorine gas, and their evacuation-related behaviors were observed in addition to analyzing the factors that affected the duration of their acute respiratory symptoms. Behavioral characteristics during the incidence of the accidental chlorine gas leakage, the estimated time of exposure, and the duration of subjective acute respiratory symptoms were investigated. In addition, clinical examination, chest radiography, and dental erosion test were performed. As variables that affected the duration of respiratory symptoms, dose group, body weight, age, sex, smoking, work period, and wearing a protective gear were included and analyzed by using the Cox proportional hazard model. Of 47 workers exposed to chlorine gas, 36 (77 %) developed more than one subjective symptom. The duration of the subjective symptoms according to exposure level significantly differed, with a median of 1 day (range, 0-5 days) in the low-exposure group and 2 days (range, 0-25 days) in the high-exposure group. Among the variables that affected the duration of the acute respiratory symptoms, which were analyzed by using the Cox proportional hazard model, only exposure level was significant (hazard ratio 2.087, 95 % CI = 1.119, 3.890). Regarding the evacuation-related behaviors, 22 workers (47 %) voluntarily evacuated to a safety zone immediately after recognizing the accidental exposure, but 25 workers (43 %) delayed evacuation until the start of mandatory evacuation (min 5, max 25 min). The duration of the subjective acute respiratory symptoms significantly differed between the low- and high-exposure groups. Among the 27 workers in the high-exposure group, 17 misjudged the toxicity after being aware of the gas leakage, which is a relatively high number.

  16. [Use of fibrin glue in the prevention of leakage in pancreatico-jejunal anastomoses].

    Science.gov (United States)

    Stojanović, M; Jeremic, M; Stojanović, P; Stojiljković, M; Gmijović, D; Stanojković, Z; Savić, V; Djordjević, V; Cvetković, Z; Kostov, M; Colović, R

    2002-01-01

    The aim of this study was to test the protective effects of fibrin sealing on the pancreatico-jejunostomy (PJA), the high-risk anastomosis following pancreas head resection. Experimental study was performed on the mongrel dogs, divided in two groups (20 animals each): Experimental group-with end to end "dunking" PJA, protected by temporary occlusion of the pancreatic duct with fibrin sealant/Tissucol/Immuno Ag/, while control group was without any protective procedure. The animals were followed 5 months in order to study: protective effects of such procedure on the PJA quantified with the percent of anastomotic leakage, effects of the exocrine secretion and effects the endocrine function Results: PJA leakage occurred in 13.33% in control group. No leakage was registered in experimental group. Biochemical, histological and electron microscopic study showed slight transitory elevation of amylase levels. Fibrin glue plug was dissolved and pancreatic juice output was reestablished 12th days postoperatively. Long term follow-up showed no damages of the endocrine and exocrine pancreas. Pancreatic duct occlusion with fibrin glue appeared to be an useful method in the prevention of pancreatico-jejunostomy leakage, without negative effects on the exocrine and endocrine pancreas.

  17. Experimental study on the leakage of gas through cracked concrete walls

    International Nuclear Information System (INIS)

    Suzuki, T.; Takiguchi, K.; Hotta, H.; Kojima, N.; Fukuhara, M.; Kimura, K.

    1989-01-01

    The air-tightness of concrete walls is important for nuclear-related facilities. A concrete wall has very high probabilities of developing cracks due to shrinkage, seismic forces or other factors. It is therefore essential to be able to predict the amount of gas which will leak through a cracked concrete wall. In the previous paper published in SmiRT-9, the experimental equation on the gas leakage through a single crack occurred in concrete was presented based on two-dimensional Poiseuille's flow. In this paper, the experimental results were examined again considering the compressibility of gas, and new equation is presented. The experiments which were similar to ones in the previous paper were carried out on several kinds of concrete using several kinds of gases, and the effects of the kinds of gaseous body, particle size of aggregates and shape of aggregates were examined

  18. Heterogeneity-enhanced gas phase formation in shallow aquifers during leakage of CO2-saturated water from geologic sequestration sites

    DEFF Research Database (Denmark)

    Plampin, Michael R.; Lassen, Rune Nørbæk; Sakaki, Toshihiro

    2014-01-01

    A primary concern for geologic carbon storage is the potential for leakage of stored carbon dioxide (CO2) into the shallow subsurface where it could degrade the quality of groundwater and surface water. In order to predict and mitigate the potentially negative impacts of CO2 leakage, it is import......A primary concern for geologic carbon storage is the potential for leakage of stored carbon dioxide (CO2) into the shallow subsurface where it could degrade the quality of groundwater and surface water. In order to predict and mitigate the potentially negative impacts of CO2 leakage...... concentration in the flowing water, the distance between the heterogeneity and the leakage location, and some fundamental properties of the porous media. Results also show that interfaces where a less permeable material overlies a more permeable material affect gas phase evolution more significantly than...

  19. Sourcing methane and carbon dioxide emissions from a small city: Influence of natural gas leakage and combustion.

    Science.gov (United States)

    Chamberlain, Samuel D; Ingraffea, Anthony R; Sparks, Jed P

    2016-11-01

    Natural gas leakage and combustion are major sources of methane (CH 4 ) and carbon dioxide (CO 2 ), respectively; however, our understanding of emissions from cities is limited. We mapped distribution pipeline leakage using a mobile CH 4 detection system, and continuously monitored atmospheric CO 2 and CH 4 concentrations and carbon isotopes (δ 13 C-CO 2 and δ 13 C-CH 4 ) for one-year above Ithaca, New York. Pipeline leakage rates were low (emission source in that wind sector. Our results demonstrate pipeline leakage rates are low in cities with a low extent of leak prone pipe, and natural gas power facilities may be an important source of urban and suburban emissions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Blockade of Vascular Endothelial Growth Factor Receptor 1 Prevents Inflammation and Vascular Leakage in Diabetic Retinopathy

    Directory of Open Access Journals (Sweden)

    Jianbo He

    2015-01-01

    Full Text Available Diabetic retinopathy (DR is a leading cause of blindness in working age adults. The objective of this study is to investigate the effects of vascular endothelial growth factor receptor 1 (VEGFR1 blockade on the complications of DR. Experimental models of diabetes were induced with streptozotocin (STZ treatment or Insulin2 gene mutation (Akita in mice. Protein expression and localization were examined by western blots (WB and immunofluorescence (IF. mRNA expression was quantified by PCR array and real-time PCR. The activity of VEGFR1 signaling was blocked by a neutralizing antibody called MF1. Vascular leakage was evaluated by measuring the leakage of [3H]-mannitol tracer into the retina and the IF staining of albumin. VEGFR1 blockade significantly inhibited diabetes-related vascular leakage, leukocytes-endothelial cell (EC adhesion (or retinal leukostasis, expression of intercellular adhesion molecule- (ICAM- 1 protein, abnormal localization and degeneration of the tight junction protein zonula occludens- (ZO- 1, and the cell adhesion protein vascular endothelial (VE cadherin. In addition, VEGFR1 blockade interfered with the gene expression of 10 new cytokines and chemokines: cxcl10, il10, ccl8, il1f6, cxcl15, ccl4, il13, ccl6, casp1, and ccr5. These results suggest that VEGFR1 mediates complications of DR and targeting this signaling pathway represents a potential therapeutic strategy for the prevention and treatment of DR.

  1. A new concept in preventing water leakage through single-wythe concrete masonry walls

    Energy Technology Data Exchange (ETDEWEB)

    Sauve, D.; Sroka, K.; Nmai, C.

    1999-07-01

    In this paper, the details of a unique patented, water-repellent concrete block design that prevents moisture that enters the core are from reaching interior surfaces are presented. The subject water leakage-controlling concrete masonry unit (WLC CMU) employs a three stage water leakage prevention process, as follows: (1) the use of water-repellent admixtures and performance-optimized mix designs to resist the passage of wind-driven rain through the block and mortar itself; (2) a horizontal beveled edge, and chamfered vertical sides of the block's face shell that provide improved access for proper joint tooling and facilities water drainage away from bed joint areas; and (3) a series of grooves and channels that prevent moisture migration across the block web surfaces, and directs it to the flawed courses where it can be effectively drained from the building envelope. Wind-driven rain tests performed by the National Concrete Masonry Association (NCMA) clearly showed the benefits of WLC CMU technology. Using identical materials, mix design, and block manufacturing equipment, a 99% reduction of moisture penetration to the core area was witnessed twice after 72 hours of ASTM E 514 testing.

  2. Modeling CO2 Gas Migration of Shallow Subsurface CO2 Leakage Experiments

    Science.gov (United States)

    Porter, M. L.; Plampin, M. R.; Pawar, R.; Illangasekare, T. H.

    2013-12-01

    Leakage of injected CO2 into shallow subsurface aquifers or back into the atmosphere at geologic carbon sequestration sites is a risk that must be minimized. One potential CO2 leakage pathway involves the transport of dissolved CO2 into a shallow aquifer where the CO2 exsolves, forming a free CO2 gas phase that subsequently migrates through the aquifer. In order to reduce the negative effects of CO2 exsolution, it is important to fully understand each of the processes controlling the movement CO2, as well as the effects of aquifer heterogeneity on the overall fate and transport of CO2. In this work, we present multiphase flow simulations of intermediate scale CO2 exsolution experiments. The multiphase flow simulations were carried out using the Finite Element Heat and Mass Transfer code (FEHM) developed at Los Alamos National Laboratory. Simulations were first designed to model experiments conducted in two different homogeneous packed sands. PEST (Parameter Estimation and Uncertainty Analysis) was used to optimize multiphase flow parameters (i.e., porosity, permeability, relative permeability, and capillary pressure) within FEHM. The optimized parameters were subsequently used to model heterogeneous experiments consisting of various packing configurations using the same sands. Comparisons of CO2 saturation between experiments and simulations will be presented and analyzed.

  3. Fluid Leakage Pathways and Shallow Gas Accumulation in Peon field, northern North Sea

    Science.gov (United States)

    Vadakkepuliyambatta, S.; Planke, S.; Bunz, S.

    2012-12-01

    Shallow gas accumulations are well known as a hazard for drilling activities as well as future prospective reservoirs. The Peon field is a huge shallow gas accumulation located in the northern North Sea discovered by Statoil in 2005. The Peon sandstone reservoir is formed as a sub-aquatic, ice-contact glaciomarine fan in Pleistocene (0.01-1.8 Ma) and is located 574m below sea level. The reservoir covers a large area of 250 km2 and contains approximately 35GSm3 gas in place. We use high-resolution P-Cable 3D seismic data to characterize the shallow gas reservoir, fluid leakage pathways and geological features in the Pleistocene sediments. The survey was acquired in 2009 and covers an area of 210 km2. The seismic data has a vertical resolution of 4.5m and provide significantly improved details of the internal structure of shallow gas reservoir and associated fluid flow. The P-Cable data provide high-resolution seismic images up to one second two-way travel time. Conventional 3D seismic data is used to analyze deeper features. In addition, well logs from exploration wells in the area are integrated with the seismic interpretation. The top of Peon sandstone reservoir is marked by a strong, polarity-reversed reflection at ~165m below seafloor. The neutron porosity log and density log distinguish gas-water contact at ~184m below seafloor. The upper regional unconformity (URU) marks the base of the sandstone body at ~198m below seafloor and separates it from westward dipping Late Pliocene sequences. Unconsolidated Pleistocene sediment sequences overlying the reservoir exhibits glacial plough marks indicating periodic glacial activity. High-amplitude reflections in the glacially deposited, unconsolidated formations above the reservoir and pull-down in reflections indicate presence of gas. Chaotic, low-amplitude reflections below the high-amplitude reflections could be due to upward migrating gas. Pockmark-like depressions, varying in width from ~200m to ~400m occur at

  4. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  5. Numerical analysis of gas leakage in the piston-cylinder clearance of reciprocating compressors considering compressibility effects

    Science.gov (United States)

    Braga, V. M.; Deschamps, C. J.

    2017-08-01

    Leakage is a major source of inefficiency in low-capacity reciprocating compressors. Not only does it lower the mass flow rate provided by the compressor, reducing its volumetric efficiency, but also gives rise to outflux of energy that decreases the isentropic efficiency. Leakage in the piston-cylinder clearance of reciprocating compressors is driven by the piston motion and pressure difference between the compression chamber and the shell internal environment. In compressors adopted for domestic refrigeration, such a clearance is usually filled by a mixture of refrigerant and lubricating oil. Besides its lubricating function, the oil also acts as sealing element for the piston-cylinder clearance, and hence leakage is expected to be more detrimental to oil-free compressors. This paper presents a model based on the Reynolds equation for compressible fluid flow to predict leakage in oil-free reciprocating compressors. The model is solved throughout the compression cycle so as to assess the effect of the clearance geometry and piston velocity on leakage and compressor efficiency. The results show that compressible fluid flow formulation must be considered for predictions of gas leakage in the cylinder-piston clearance.

  6. Lyman-continuum leakage as dominant source of diffuse ionized gas in the Antennae galaxy

    Science.gov (United States)

    Weilbacher, Peter M.; Monreal-Ibero, Ana; Verhamme, Anne; Sandin, Christer; Steinmetz, Matthias; Kollatschny, Wolfram; Krajnović, Davor; Kamann, Sebastian; Roth, Martin M.; Erroz-Ferrer, Santiago; Marino, Raffaella Anna; Maseda, Michael V.; Wendt, Martin; Bacon, Roland; Dreizler, Stefan; Richard, Johan; Wisotzki, Lutz

    2018-04-01

    The Antennae galaxy (NGC 4038/39) is the closest major interacting galaxy system and is therefore often studied as a merger prototype. We present the first comprehensive integral field spectroscopic dataset of this system, observed with the MUSE instrument at the ESO VLT. We cover the two regions in this system which exhibit recent star formation: the central galaxy interaction and a region near the tip of the southern tidal tail. In these fields, we detect HII regions and diffuse ionized gas to unprecedented depth. About 15% of the ionized gas was undetected by previous observing campaigns. This newly detected faint ionized gas is visible everywhere around the central merger, and shows filamentary structure. We estimate diffuse gas fractions of about 60% in the central field and 10% in the southern region. We are able to show that the southern region contains a significantly different population of HII regions, showing fainter luminosities. By comparing HII region luminosities with the HST catalog of young star clusters in the central field, we estimate that there is enough Lyman-continuum leakage in the merger to explain the amount of diffuse ionized gas that we detect. We compare the Lyman-continuum escape fraction of each HII region against emission line ratios that are sensitive to the ionization parameter. While we find no systematic trend between these properties, the most extreme line ratios seem to be strong indicators of density bounded ionization. Extrapolating the Lyman-continuum escape fractions to the southern region, we conclude that simply from the comparison of the young stellar populations to the ionized gas there is no need to invoke other ionization mechanisms than Lyman-continuum leaking HII regions for the diffuse ionized gas in the Antennae. FITS images and Table of HII regions are available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/611/A95 and at http://muse-vlt.eu/science/antennae/

  7. 49 CFR 176.605 - Care following leakage or sifting of Division 2.3 (poisonous gas) and Division 6.1 (poisonous...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Care following leakage or sifting of Division 2.3... (Poisonous Gas) and Division 6.1 (Poisonous) Materials § 176.605 Care following leakage or sifting of... package of a Division 2.3 (poisonous gas) or Division 6.1 (poisonous) material which has leaked or sifted...

  8. Integrated experimental and modeling assessment of potential effects of gas leakages on groundwater composition

    Science.gov (United States)

    Berta, Marton; Dethlefsen, Frank; Ebert, Markus; Schäfer, Dirk

    2017-04-01

    Storing renewably produced energy is one of the major challenges for the energy systems of the upcoming decades. Power-to-gas technologies coupled to geological storage of compressed air, methane, and hydrogen offer a comparatively safe and cost-efficient way for large-scale energy storage. However, the stored gases can potentially escape from their geological reservoir and may thus affect protected natural goods such as groundwater. The geochemical reactions responsible for these composition changes are usually investigated separately in experiments and numerical models. Here we present the outcomes of an integrated experimental and modeling approach through the example of a compressed air leakage scenario. A main consequence of the presence of oxygen to be assessed in an aquifer is pyrite oxidation, well known from acid mine drainage sites. However, in contrast to acid mine drainage sites exhibiting unsaturated sediments and fed by meteoric low-carbonate water, aquifers such as in Northern Germany contain a considerable amount of solid and dissolved inorganic carbon species potentially buffering pH changes. High pressure flow-through column experiments representing an intrusion of compressed air into an aquifer were carried out to quantify pyrite oxidation kinetics and to incorporate the observations into a descriptive reaction model. Surface passivation was found to decrease the reactivity of pyrite by more than 90% after a few months of experimental run time. We propose that the carbonate buffer system enables the precipitation of a passivating mineral layer on the pyrite surface reducing the overall reaction rate significantly. Consequently, an established rate law from the literature was extended by a reactive surface passivation term[1]. This improved reaction rate equation was incorporated into a 3D numerical model using OpenGeoSys with parameters representing similarly typical aquifer conditions the experiments had characterized. These boundaries include

  9. The Use of Low-frequency Active Channel Signals in an Information Leakage Detection and Prevention Systems

    Directory of Open Access Journals (Sweden)

    A. V. Mamaev

    2011-06-01

    Full Text Available This article describes a solution for the protection of the temporary lifting of control over the target machine, while using information leakage detection and prevention systems. It is proposed to use a specially designed channel for alert’s signals through the computer’s power supply.

  10. Environmental legacy of an underground gas well blowout: long-term effects of gas and brine leakage on groundwater quality

    Science.gov (United States)

    Schout, Gilian; Hartog, Niels; Majid Hassanizadeh, S.; Griffioen, Jasper

    2017-04-01

    research sheds new light on the long-term effects of natural gas and brine leakage on groundwater quality, which is considered one of the main environmental hazards related to hydraulic fracturing and unconventional gas production in general. Notably, it shows that the anaerobic oxidation of methane may play a major role in containing the effects of uncontrolled gas migration from reservoirs to shallow aquifers.

  11. A Numerical Study of Gas Injection and Caprock Leakage from Yort-e-Shah Aquifer in Iran

    Directory of Open Access Journals (Sweden)

    H. S. Rad

    2017-08-01

    Full Text Available In order to mitigate the adverse effects of global warming due to anthropogenic CO2 emission into the atmosphere, geological sequestration of CO2 into subsurface formations has been investigated by many studies over the last decade. However, selection of formations and sites for any field application is still open to debate. The most important properties of a formation suitable for carbon sequestration are those which impact the fluid flow processes. The injection or extraction of gas can change the pore pressure within the reservoir, which in turn results in redistribution of the stress field. These events may cause considerably leakage of the fluid into the surrounding geological formations or ground surface. The main objective of this paper is to evaluate the potential of Yort-e-Shah aquifer for CO2 storage, through a series of analyses with a simplified numerical model. The numerical results suggest that the optimum injection pressure in Yort-e-Shah aquifer is about 15.51 MPa with a safety factor of about 1.7. The results of the fluid pressure and gas plume expansion are presented. Also, an analysis was carried out for a case with leak through cap rock. When there is no leak, the pressure within the aquifer is stable, while on the other hand, the pressure in case of leakage is slightly smaller. In case of leakage, the pressure is lowest in the middle of the reservoir, mainly because the nodes at the middle of the aquifer are influenced by all the leakage points, while around the wellbore or near the end of gas plume, are affected less due to their longer distance to leakage points.

  12. Prevention through policy : Urban macroplastic leakages to the marine environment during extreme rainfall events

    NARCIS (Netherlands)

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic

  13. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events.

    Science.gov (United States)

    Axelsson, Charles; van Sebille, Erik

    2017-11-15

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while cities actively create policies that reduce plastic leakages, more needs to be done. Nonetheless, these policies are economically, socially and environmentally cobeneficial to the city environment. While the lack of political engagement and economic concerns limit these policies, lacking social motivation and engagement is the largest limitation towards implementing policy. We recommend cities to incentivize citizen and municipal engagement with responsible usage of plastics, cleaning the environment and preparing for future extreme rainfall events. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  14. F-actin-rich contractile endothelial pores prevent vascular leakage during leukocyte diapedesis through local RhoA signalling

    Science.gov (United States)

    Heemskerk, Niels; Schimmel, Lilian; Oort, Chantal; van Rijssel, Jos; Yin, Taofei; Ma, Bin; van Unen, Jakobus; Pitter, Bettina; Huveneers, Stephan; Goedhart, Joachim; Wu, Yi; Montanez, Eloi; Woodfin, Abigail; van Buul, Jaap D.

    2016-01-01

    During immune surveillance and inflammation, leukocytes exit the vasculature through transient openings in the endothelium without causing plasma leakage. However, the exact mechanisms behind this intriguing phenomenon are still unknown. Here we report that maintenance of endothelial barrier integrity during leukocyte diapedesis requires local endothelial RhoA cycling. Endothelial RhoA depletion in vitro or Rho inhibition in vivo provokes neutrophil-induced vascular leakage that manifests during the physical movement of neutrophils through the endothelial layer. Local RhoA activation initiates the formation of contractile F-actin structures that surround emigrating neutrophils. These structures that surround neutrophil-induced endothelial pores prevent plasma leakage through actomyosin-based pore confinement. Mechanistically, we found that the initiation of RhoA activity involves ICAM-1 and the Rho GEFs Ect2 and LARG. In addition, regulation of actomyosin-based endothelial pore confinement involves ROCK2b, but not ROCK1. Thus, endothelial cells assemble RhoA-controlled contractile F-actin structures around endothelial pores that prevent vascular leakage during leukocyte extravasation. PMID:26814335

  15. The prevention of colorectal anastomotic leakage with tissue adhesives in a contaminated environment is associated with the presence of anti-inflammatory macrophages

    NARCIS (Netherlands)

    Z. Wu (Zhouqiao); K.A. Vakalopoulos (Konstantinos); G.S.A. ter Hoeve-Boersema (Simone); L.F. Kroese (Leonard); K.H. Lam (King); P.H. van der Horst (Paul); I.M. Mulder (Irene); Y.M. Bastiaansen-Jenniskens (Yvonne); G.J. Kleinrensink (Gert Jan); J. Jeekel (Johannes); J.F. Lange (Johan)

    2014-01-01

    textabstractBackground: Colorectal anastomoses created in a contaminated environment result in a high leakage rate. This study investigated whether using anastomotic sealants (TissuCol®, Histoacryl® Flex, and Duraseal®) prevents leakage in a rat peritonitis model. Study design: Sixty-seven Wistar

  16. Effect of Human Amniotic Membrane on Prevention of Colorectal Anastomosis Leakage in Cases with Neoadjuvant Radiotherapy: An Experimental Animal Study

    Directory of Open Access Journals (Sweden)

    Sam Moslemi

    2016-11-01

    Full Text Available Background: Radiotherapy is one of the most important factors which results in negative effects on wound healing and increases anastomosis leakage. Diverting loop ileostomy has been usually performed after colorectal anastomosis in cases of colorectal cancer with a history of neoadjuvant radiotherapy to decrease the chance of leakage. Considering the side effects of diverting loop ileostomy, the objective of the present study is to investigate the effect of human amniotic membrane (HAM on colorectal anastomosis leakage after neo-adjuvant radiotherapy. Methods: In this experimental animal study, 20 crossbreed rabbits were randomly divided into two groups (case group: 13 rabbits, control group: 7 rabbits after receiving an equal dose of external beam radiation. Four weeks after irradiation, resection of 4 cm of colorectal segment and end-to-end single layer anastomosis were conducted. In the case group, a 2×2 cm wrap of HAM applied around the site of anastomosis. Eight weeks later, all the survived rabbits were sacrificed. A segment of anastomotic sites was resected in all expired and survived rabbits and sent for pathological evaluation. Mann-Whitney U Test (SPSS for Windows, Ver. 16, Chicago, IL was applied to analyze healing scores between the two groups. Results: Due to anastomosis dehiscence, 5 rabbits expired in the control group, but all the 13 rabbits (case group survived after 8 weeks and showed no leakage. In addition, pathological evaluation revealed significant epithelialization and neovascularization in the case group. Statistically, healing score was higher in the case group rather than the control group (P<0.001. Conclusion: To prevent post irradiation colorectal anastomosis leakage, the use of HAM might play a significant role and a feasible technical approach.

  17. Gas theft: Prevention and detection

    International Nuclear Information System (INIS)

    Johnson, G.

    1992-01-01

    The problem of gas theft is discussed. Roughly 2% of gas and power customers in the United States either steal or attempt to steal service. Most diversion programs focus on theft from a revenue protection viewpoint, however there is often insufficient money recovered to justify an anti-theft program. Successful action often involves focusing on large volume users. Safety should be a prime consideration in searching out gas theft, as many people have been killed or injured as a result of careless theft. A brief review is presented of anti-theft devices such as locks and seals; automated meter reading can also help reduce theft. The best defence against theft is a highly trained and motivated field staff, especially meter readers, and a computer billing program that monitors changes in gas usage. Fixed bypasses may be unlocked and used at will; fraud is also common. Investigation and prosecution should be carried out by trained personnel following a carefully developed procedure. Safety issues should be stressed, and every effort should be made to avoid the appearance that the justice system is being used as a bill collector. 3 refs

  18. An Ice Block: A Novel Technique of Successful Prevention of Cement Leakage Using an Ice Ball

    Energy Technology Data Exchange (ETDEWEB)

    Uri, Ishaq Fahmi, E-mail: uri.isaac@gmail.com [The Royal National Orthopaedic Hospital (United Kingdom); Garnon, Julien, E-mail: juliengarnon@gmail.com; Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpital Universitaire de Strasbourg, Service d’Imagerie Interventionnelle (France)

    2015-04-15

    We report three cases of painful bone metastases with extraosseous invasion treated with cementoplasty and cryoablation. Due to significant cortical loss in all cases, the ice ball was used simultaneously during cementoplasty to deter potential cement leakage. This was achieved by direct application of the ice ball against the cortical surface, resulting in adequate consolidation and successful containment of the cement within the treated bones. To the authors’ knowledge, this is the first report to describe such a combined technique.

  19. A radiotracer technique for testing a high pressure gas compressor for oil leakage

    International Nuclear Information System (INIS)

    Eapen, A.C.; Kirti; Jain, S.K.; Gupta, P.P.

    1979-01-01

    The radiotracer investigations carried out at NOCIL, Bombay, to measure the amount of lubrication oil present in the gas being compressed in a 1000 H.P. centrifugal compressor are described. By injecting a few mCi 131 I labelled glyceryl trioleate tracer and monitoring the radioactivity of the outlet gas for about 20 hours, the extent of the oil present in the gas could be determined. (auth.)

  20. Continuous CO2 gas monitoring to clarify natural pattern and artificial leakage signals

    Science.gov (United States)

    Joun, W.; Ha, S. W.; Joo, Y. J.; Lee, S. S.; Lee, K. K.

    2017-12-01

    Continuous CO2 gas monitoring at shallow aquifer is significant for early detection and immediate handling of an aquifer impacted by leaking CO2 gas from the sequestration reservoir. However, it is difficult to decide the origin of CO2 gas because detected CO2 includes not only leaked CO2 but also naturally emitted CO2. We performed CO2 injection and monitoring tests in a shallow aquifer. Before the injection of CO2 infused water, we have conducted continuous monitoring of multi-level soil CO2 gas concentration and physical parameters such as temperature, humidity, pressure, wind speed and direction, and precipitation. The monitoring data represented that CO2 gas concentrations in unsaturated soil zone borehole showed differences at depths and daily variation (360 to 6980 ppm volume). Based on the observed data at 5 m and 8 m depths, vertical flux of gas was calculated as 0.471 L/min (LPM) for inflow from 5 m to 8 m and 9.42E-2 LPM for outflow from 8 m to 5 m. The numerical and analytical models were used to calculate the vertical flux of gas and to compare with observations. The results showed that pressure-based modeling could not explain the rapid change of CO2 gas concentration in borehole. Acknowledgement Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2 Storage" from the KEITI (Project Number: 2014001810003)

  1. A practical approach to estimate diffusional leakages of leaf chamber of open gas exchange systems using intact leaves.

    Science.gov (United States)

    Kitao, Mitsutoshi; Harayama, Hisanori; Uemura, Akira

    2017-11-01

    We propose a novel approach to determine the coefficient of CO 2 diffusional leakage (k _CO2 ) in the chamber of a portable open gas exchange system (Li-6400, Li-Cor Inc., NE, USA) using intact leaves. Assuming that dark respiration rate (R n ) is constant at various CO 2 concentrations, at least in a short term, k _CO2 should be the value that makes the leak-corrected R n constant. We used 2 representative tree species native to northern Japan, Japanese white birch (Betula platyphylla var. japonica) and Japanese oak (Quercus mongolica var. crispula), to determine k _CO2 , by measuring R n at various CO 2 concentrations. Irrespective of the species, k _CO2 estimated by the present approach was well correlated with the diffusional leak coefficient (k _flow ) estimated by the generally used approach that utilizes CO 2 concentrations inside and outside the chamber based on thermally killed leaves at various flow rates. Furthermore, the present approach does not require the ambient CO 2 concentration outside the chamber (C a ) if C a in the laboratory is stable, which provides a feasible way to correct the photosynthetic rate, taking diffusional leakage into account. © 2017 John Wiley & Sons Ltd.

  2. a Real-Time GIS Platform for High Sour Gas Leakage Simulation, Evaluation and Visualization

    Science.gov (United States)

    Li, M.; Liu, H.; Yang, C.

    2015-07-01

    The development of high-sulfur gas fields, also known as sour gas field, is faced with a series of safety control and emergency management problems. The GIS-based emergency response system is placed high expectations under the consideration of high pressure, high content, complex terrain and highly density population in Sichuan Basin, southwest China. The most researches on high hydrogen sulphide gas dispersion simulation and evaluation are used for environmental impact assessment (EIA) or emergency preparedness planning. This paper introduces a real-time GIS platform for high-sulfur gas emergency response. Combining with real-time data from the leak detection systems and the meteorological monitoring stations, GIS platform provides the functions of simulating, evaluating and displaying of the different spatial-temporal toxic gas distribution patterns and evaluation results. This paper firstly proposes the architecture of Emergency Response/Management System, secondly explains EPA's Gaussian dispersion model CALPUFF simulation workflow under high complex terrain and real-time data, thirdly explains the emergency workflow and spatial analysis functions of computing the accident influencing areas, population and the optimal evacuation routes. Finally, a well blow scenarios is used for verify the system. The study shows that GIS platform which integrates the real-time data and CALPUFF models will be one of the essential operational platforms for high-sulfur gas fields emergency management.

  3. Long-term fecal diverting device for the prevention of sepsis in case of colorectal anastomotic leakage: an animal experiment.

    Science.gov (United States)

    Kim, Jae Hwang; Jung, Sang Hun; Kim, Yong-Jin; Park, Se-Ll; Kim, Dae-Hwan

    2013-04-01

    A new fecal diverting device (FDD) was fabricated for fecal diversion from the proximal colon above the anastomosis to outside the anus for protecting the rectal anastomosis. The aim of the study is to evaluate the safety and effectiveness of the FDD. After a pilot study, a prospective observational trial was performed in 34 mongrel dogs. The experiment comprised of segmental resection and anastomosis of the colon, fixation of the FDD, and observation for 3 weeks (n = 15) and more than 3 weeks (n = 19) without initiation of parenteral nutrition. Four cases of perioperative death unrelated to the FDD were excluded. Twenty-six (87 %) of the 30 dogs survived. Sixteen (53 %) dogs were able to retain the FDD for more than 3 weeks until 82 days. The autopsy findings revealed that four (15 %) dogs showed colonic wall erosions and mucosal scarring respectively at the band fixation area without evidence of serious septic complications. The surviving dogs retained the FDD for more than 6 days. Mortality occurred in four of the five dogs that expelled the FDD within three postoperative days. A closed abscess cavity as the evidence of anastomotic leakage was noted in seven (23 %) of the surviving dogs. The newly designed fecal diverting device can be retained for more than 3 weeks until 82 days without any serious complications. The FDD may prevent sepsis in case of anastomotic leakage if it is retained for more than 6 days.

  4. Microseismicity Linked to Gas Migration and Leakage on the Western Svalbard Shelf

    Science.gov (United States)

    Franek, Peter; Plaza-Faverola, Andreia; Mienert, Jürgen; Buenz, Stefan; Ferré, Bénédicte; Hubbard, Alun

    2017-12-01

    The continental margin off Prins Karls Forland, western Svalbard, is characterized by widespread natural gas seepage into the water column at and upslope of the gas hydrate stability zone. We deployed an ocean bottom seismometer integrated into the MASOX (Monitoring Arctic Seafloor-Ocean Exchange) automated seabed observatory at the pinch-out of this zone at 389 m water depth to investigate passive seismicity over a continuous 297 day period from 13 October 2010. An automated triggering algorithm was applied to detect over 220,000 short duration events (SDEs) defined as having a duration of less than 1 s. The analysis reveals two different types of SDEs, each with a distinctive characteristic seismic signature. We infer that the first type consists of vocal signals generated by moving mammals, likely finback whales. The second type corresponds to signals with a source within a few hundred meters of the seismometer, either due east or west, that vary on short (˜tens of days) and seasonal time scales. Based on evidence of prevalent seafloor seepage and subseafloor gas accumulations, we hypothesize that the second type of SDEs is related to subseafloor fluid migration and gas seepage. Furthermore, we postulate that the observed temporal variations in microseismicity are driven by transient fluid release and due to the dynamics of thermally forced, seasonal gas hydrate decomposition. Our analysis presents a novel technique for monitoring the duration, intensity, and periodicity of fluid migration and seepage at the seabed and can help elucidate the environmental controls on gas hydrate decomposition and release.

  5. Technical Note: Detection of gas bubble leakage via correlation of water column multibeam images

    Directory of Open Access Journals (Sweden)

    J. Schneider von Deimling

    2012-03-01

    Full Text Available Hydroacoustic detection of natural gas release from the seafloor has been conducted in the past by using singlebeam echosounders. In contrast, modern multibeam swath mapping systems allow much wider coverage, higher resolution, and offer 3-D spatial correlation. Up to the present, the extremely high data rate hampers water column backscatter investigations and more sophisticated visualization and processing techniques are needed. Here, we present water column backscatter data acquired with a 50 kHz prototype multibeam system over a period of 75 seconds. Display types are of swath-images as well as of a "re-sorted" singlebeam presentation. Thus, individual and/or groups of gas bubbles rising from the 24 m deep seafloor clearly emerge in the acoustic images, making it possible to estimate rise velocities. A sophisticated processing scheme is introduced to identify those rising gas bubbles in the hydroacoustic data. We apply a cross-correlation technique adapted from particle imaging velocimetry (PIV to the acoustic backscatter images. Temporal and spatial drift patterns of the bubbles are assessed and are shown to match very well to measured and theoretical rise patterns. The application of this processing to our field data gives clear results with respect to unambiguous bubble detection and remote bubble rise velocimetry. The method can identify and exclude the main source of misinterpretations, i.e. fish-mediated echoes. Although image-based cross-correlation techniques are well known in the field of fluid mechanics for high resolution and non-inversive current flow field analysis, we present the first application of this technique as an acoustic bubble detector.

  6. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  7. Preventive testing and leakage detection in pipe-lines of steam condensers and generators of a PWR type reactor

    International Nuclear Information System (INIS)

    Canalini, A.; Carvalho, N.C. de

    1985-01-01

    The non-destructive methods: Spum, Helium and Hydrostatic used in leakage detection in condenser pipelines for PWR type reactors are presented. The time, costs, sensitivity, resources necessary and personnel development factors are considered to choose adequated method, in function of nuclear power plant conditions. The leakage tests are applied in pressurized systems or vacuum. Eddy Current testing is used in condensers and steam generators aiming to avoid leakage in these equipments. The spume testing for leakage detection in condenser pipelines - which operation - and hydrostatic testing for leakage detection through reaming with shutdown - were most efficients. The Helium testing applied in pressurized systems or submitted to vacuum systems presented satisfactory results. The Eddy Current testing in condenser and steam generator pipelines reached desired objective, reducing leakage in the first and preserving the integrity in the second. (M.C.K.) [pt

  8. Rejection of seamless pipe noise in magnetic flux leakage data obtained from gas pipeline inspection

    Science.gov (United States)

    Afzal, Muhammad; Udpa, Satish; Udpa, Lalita; Lord, William

    2000-05-01

    Natural gas is traditionally transmitted from production facilities to customer locations through a vast pipeline network. A major segment of this network employs seamless pipes. This is especially true for smaller diameter transmission and distribution lines. Manufacturing process associated with the production of seamless pipes contribute to a helical variation in the pipe along the axis. The deformation introduces an artifact in the data obtained from MFL inspection of these pipelines. This seamless pipe noise is usually correlated with signals generated by defects and other elements (joints, tees, etc.) in pipelines, and can therefore, mask their indications in MFL data. This warrants the need for methods to improve signal-to-noise ratio (SNR) in MFL data from seamless pipes. This paper presents a technique for detecting signals in MFL data from seamless pipes. The approach processes the data in various steps. First, a wavelet based denoising technique is applied to reduce the noise due to instrumentation and other sources. An adaptive filtering approach is then applied to reject seamless noise in the data. Since the inspection of pipelines typically generates vast amounts of data, it is imperative that the algorithm be computationally efficient. The processing method has to be robust in that it should be data independent. The approach described in this paper meet these criteria. Results from application of the approach to data from field tests are presented.

  9. A Location Method Using Sensor Arrays for Continuous Gas Leakage in Integrally Stiffened Plates Based on the Acoustic Characteristics of the Stiffener

    Directory of Open Access Journals (Sweden)

    Xu Bian

    2015-09-01

    Full Text Available This paper proposes a continuous leakage location method based on the ultrasonic array sensor, which is specific to continuous gas leakage in a pressure container with an integral stiffener. This method collects the ultrasonic signals generated from the leakage hole through the piezoelectric ultrasonic sensor array, and analyzes the space-time correlation of every collected signal in the array. Meanwhile, it combines with the method of frequency compensation and superposition in time domain (SITD, based on the acoustic characteristics of the stiffener, to obtain a high-accuracy location result on the stiffener wall. According to the experimental results, the method successfully solves the orientation problem concerning continuous ultrasonic signals generated from leakage sources, and acquires high accuracy location information on the leakage source using a combination of multiple sets of orienting results. The mean value of location absolute error is 13.51 mm on the one-square-meter plate with an integral stiffener (4 mm width; 20 mm height; 197 mm spacing, and the maximum location absolute error is generally within a ±25 mm interval.

  10. Impact of high cholesterol in a Parkinson's disease model: Prevention of lysosomal leakage versus stimulation of α-synuclein aggregation.

    Science.gov (United States)

    Eriksson, Ida; Nath, Sangeeta; Bornefall, Per; Giraldo, Ana Maria Villamil; Öllinger, Karin

    2017-03-01

    Parkinson's disease is characterized by accumulation of intraneuronal cytoplasmic inclusions, Lewy bodies, which mainly consist of aggregated α-synuclein. Controversies exist as to whether high blood cholesterol is a risk factor for the development of the disease and whether statin treatment could have a protective effect. Using a model system of BE(2)-M17 neuroblastoma cells treated with the neurotoxin 1-methyl-4-phenylpyridinium (MPP + ), we found that MPP + -induced cell death was accompanied by cholesterol accumulation in a lysosomal-like pattern in pre-apoptotic cells. To study the effects of lysosomal cholesterol accumulation, we increased lysosomal cholesterol through pre-treatment with U18666A and found delayed leakage of lysosomal contents into the cytosol, which reduced cell death. This suggests that increased lysosomal cholesterol is a stress response mechanism to protect lysosomal membrane integrity in response to early apoptotic stress. However, high cholesterol also stimulated the accumulation of α-synuclein. Treatment with the cholesterol-lowering drug lovastatin reduced MPP + -induced cell death by inhibiting the production of reactive oxygen species, but did not prevent lysosomal cholesterol increase nor affect α-synuclein accumulation. Our study indicates a dual role of high cholesterol in Parkinson's disease, in which it acts both as a protector against lysosomal membrane permeabilization and as a stimulator of α-synuclein accumulation. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    Science.gov (United States)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier

  12. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.

    Science.gov (United States)

    Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro

    2015-12-01

    The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial

  13. Why heavy oilfields exist? The dynamic interplay of oil charge, basin dynamics, caprock leakage and gas generating biodegradation that produces heavy oilfields

    Science.gov (United States)

    Adams, J. J.; Larter, S. R.; Huang, H.; Bennett, B.

    2008-12-01

    Heavy oil and bitumen resources develop by extensive in-reservoir oil biodegradation resulting in a wide range of oil compositional gradients that reflect the complex interplay of oil charge rate and composition, biodegradation in oil-water transition zones at the base of oil columns and geologically controlled in-reservoir diffusive mixing over geological time. Worldwide, observed compositional gradients are maintained by unaltered oil charge near the top of reservoirs and concomitant degradation at the base of the reservoirs at rates comparable to the charge rates of oil fields. Across the Alberta oil sands, elevated CO2, high CH4 and low C2+ gas contents, steep oil compositional gradients, high aqueous bicarbonate concentrations and isotopic values in equilibrium with enriched d13CCO2 gas signatures are indicative of active persistence of active biodegradation to the present. Numerical models of carbon isotope systematics identify the dominant reaction pathway of subsurface hydrocarbon biodegradation as methanogenic alkane degradation by CO2 reduction, which produces large volumes of isotopically light methane and heavy CO2 in solution gas. Simple charge-degrade numerical models predict generation of 3 to 6 times reservoir volumes of biogenic gas in the genesis of heavy oil over geological time, which would have displaced oils from the traps. Gas caps in shallow reservoirs are small at best, suggesting seal leakage is pervasive and this is confirmed by degraded oil in many heavy oil caprocks. Also much less CO2 is measured in biodegraded oil field gases than is predicted based on reaction stoichiometry. The paucity of large gas caps, evidence of methane-rich and sometimes oil charged cap rocks, anomalously high formation water alkalinity and enriched aqueous d13Ccarbonate values in shallow Alberta biodegraded oil reservoirs point to leaky reservoir top seals and dissolution of biogenic gas into the water and oil phases. Indeed we consider top seal leakage of

  14. Novel dural incision and closure procedure for preventing postoperative cerebrospinal fluid leakage during the surgical removal of dumbbell-shaped spinal tumors: technical note.

    Science.gov (United States)

    Ito, Kiyoshi; Aoyama, Tatsuro; Nakamura, Takuya; Hanaoka, Yoshiki; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro

    2016-11-01

    The authors report on a new method for removing dumbbell-shaped spinal tumors that avoids the risk of postoperative cerebrospinal fluid (CSF) leakage. Adequate visualization of the intra- and extradural components of the tumor is achieved with the use of separate dural incisions. First, the dura mater is opened along the dural theca to provide adequate visualization of the intradural portion of the mass; then, a second incision is made along the nerve root to remove the extradural component. Meticulous suturing is essential in intradural lesion cases; however, the dura mater is usually thin and fragile in such cases. During suturing with a needle and thread, the dura mater can become lacerated proximal to the needle holes and result in CSF leakage. In the authors' technique, instead of using a needle and thread, nonpenetrating vascular clips were used to close the dural incisions. When operating on dumbbell-shaped spinal tumors, the authors found that the "separate-dural-incision method" was preferable to the conventional T-shaped dural incision method because no dural defects occurred after the intradural procedure and meticulous dural closure with vascular clips was achieved. The authors conclude that the novel separate-dural-incision method for removing dumbbell-shaped tumors and the use of nonpenetrating vascular clips permits reliable dural closure, prevents postoperative CSF leakage, and promises good postoperative clinical results.

  15. The applicability of C-14 measurements in the soil gas for the assessment of leakage out of underground carbon dioxide reservoirs

    Directory of Open Access Journals (Sweden)

    Chałupnik Stanisław

    2014-03-01

    Full Text Available Poland, due to the ratification of the Kioto Protocol, is obliged to diminish the emission of greenhouse gases. One of the possible solutions of this problem is CO2 sequestration (CCS - carbon capture and storage. Such an option is a priority in the European Union. On the other hand, CO2 sequestration may be potentially risky in the case of gas leakage from underground reservoirs. The most dangerous event may be a sudden release of the gas onto the surface. Therefore, it is very important to know if there is any escape of CO2 from underground gas reservoirs, created as a result of sequestration. Such information is crucial to ensure safety of the population in areas located above geological reservoirs. It is possible to assess the origin of carbon dioxide, if the measurement of radiocarbon 14C concentration in this gas is done. If CO2 contains no 14C, it means, that the origin of the gas is either geological or the gas has been produced as a result of combustion of fossil fuels, like coal. A lot of efforts are focused on the development of monitoring methods to ensure safety of CO2 sequestration in geological formations. A radiometric method has been tested for such a purpose. The main goal of the investigations was to check the application possibility of such a method. The technique is based on the liquid scintillation counting of samples. The gas sample is at first bubbled through the carbon dioxide adsorbent, afterwards the adsorbent is mixed with a dedicated cocktail and measured in a low-background liquid scintillation spectrometer Quantulus. The described method enables measurements of 14C in mine and soil gas samples.

  16. A comparison of experimental and theoretical results for leakage, pressure distribution, and rotordynamic coefficients for annular gas seals

    Science.gov (United States)

    Nicks, C. O.; Childs, D. W.

    1984-01-01

    The importance of seal behavior in rotordynamics is discussed and current annular seal theory is reviewed. A Nelson's analytical-computational method for determining rotordynamic coefficients for this type of compressible-flow seal is outlined. Various means for the experimental identification of the dynamic coefficients are given, and the method employed at the Texas A and M University (TAMU) test facility is explained. The TAMU test apparatus is described, and the test procedures are discussed. Experimental results, including leakage, entrance-loss coefficients, pressure distributions, and rotordynamic coefficients for a smooth and a honeycomb constant-clearance seal are presented and compared to theoretical results from Nelson's analysis. The results for both seals show little sensitivity to the running speed over the test range. Agreement between test results and theory for leakage through the seal is satisfactory. Test results for direct stiffness show a greater sensitivity to fluid pre-rotation than predicted. Results also indicate that the deliberately roughened surface of the honeycomb seal provides improved stability versus the smooth seal.

  17. Methane Leakage from Oil & Gas Operations. What have we learned from recent studies in the U.S.?

    Science.gov (United States)

    Zavala-Araiza, Daniel; Hamburg, Steven

    2016-04-01

    Methane, the principal component of natural gas, is a powerful greenhouse gas. Methane losses from the natural gas supply chain erode the climate benefits of fuel switching to natural gas from other fossil fuels, reducing or eliminating them for several decades or longer. Global data on methane emissions from the oil and gas sector is uncertain and as a consequence, measuring and characterizing methane emissions is critical to the design of effective mitigation strategies. In this work, we synthesize lessons learned from dozens of U.S. studies that characterized methane emissions along each stage of the natural gas supply chain. These results are relevant to the design of methane measurement campaigns outside the U.S. A recurring theme in the research conducted in the U.S. is that public emissions inventories (e.g., The U.S. Environmental Protection Agency's National Greenhouse gas Inventory) tend to underestimate emissions for two key reasons: (1) use of non-representative emission factors and (2) inaccurate activity data (incomplete counts of facilities and equipment). Similarly, the accuracy of emission factors and the effectiveness of mitigation strategies are heavily affected by the existence of low-probability, unpredictable high emitters-which have been observed all along the supply chain- and are spatiotemporally variable. We conducted a coordinated campaign to measure methane emissions in a major gas producing region of the U.S. (Barnett Shale region of Texas) using a diversity of approaches. As part of this study we identified methods for effective quantification of regional fossil methane emissions using atmospheric data (through replicate mass balance flights and source apportionment using methane to ethane ratios) as well as how to build an accurate inventory that includes a statistical estimator that more rigorously captures the magnitude and frequency of high emitters. We found agreement between large-scale atmospheric sampling estimates and source

  18. Fundamental Study on the Dynamics of Heterogeneity-Enhanced CO2 Gas Evolution in the Shallow Subsurface During Possible Leakage from Deep Geologic Storage Sites

    Science.gov (United States)

    Plampin, M. R.; Lassen, R. N.; Sakaki, T.; Pawar, R.; Jensen, K.; Illangasekare, T. H.

    2013-12-01

    A concern for geologic carbon sequestration is the potential for CO2 stored in deep geologic formations to leak upward into shallow freshwater aquifers where it can have potentially detrimental impacts to the environment and human health. Understanding the mechanisms of CO2 exsolution, migration and accumulation (collectively referred to as 'gas evolution') in the shallow subsurface is critical to predict and mitigate the environmental impacts. During leakage, CO2 can move either as free-phase or as a dissolved component of formation brine. CO2 dissolved in brine may travel upward into shallow freshwater systems, and the gas may be released from solution. In the shallow aquifer, the exsolved gas may accumulate near interfaces between soil types, and/or create flow paths that allow the gas to escape through the vadose zone to the atmosphere. The process of gas evolution in the shallow subsurface is controlled by various factors, including temperature, dissolved CO2 concentration, water pressure, background water flow rate, and geologic heterogeneity. However, the conditions under which heterogeneity controls gas phase evolution have not yet been precisely defined and can therefore not yet be incorporated into models used for environmental risk assessment. The primary goal of this study is to conduct controlled laboratory experiments to help fill this knowledge gap. With this as a goal, a series of intermediate-scale laboratory experiments were conducted to observe CO2 gas evolution in porous media at multiple scales. Deionized water was saturated with dissolved CO2 gas under a specified pressure (the saturation pressure) before being injected at a constant volumetric flow rate into the bottom of a 1.7 meter-tall by 5.7 centimeter-diameter column or a 2.4 meter-tall by 40 centimeter-wide column that were both filled with sand in various heterogeneous packing configurations. Both test systems were initially saturated with fresh water and instrumented with soil

  19. Design and demonstration of an analysis Information system for magnetic flux leakage inspection of natural gas pipeline. Final letter report

    Energy Technology Data Exchange (ETDEWEB)

    Schuster, G.J.; Saffell, B.A.

    1996-10-01

    A staff exchange was conducted for the mutual benefit of the Department of Energy, the Gas Research Institute (GRI), Vetco Pipeline Services Inc. (VPSI), and the Pacific Northwest National Laboratory. This staff exchange provided direct exposure by a Laboratory staff member knowledgeable in inspection, integrity assessment, and robotic capabilities of the Laboratory to the needs of the natural gas pipeline industry. The project included an assignment to the GRI Pipeline Simulation Facility (PSF) during the period preceding the commissioning of the flow loop. GRI is interested in exploiting advanced technology at the National Laboratories. To provide a sense of the market impact, it is estimated that $3 billion was spent in 1993 for the repair, renovation, and replacement of distribution piping. GRI has goals of saving the distribution industry $500 million in Operations and Maintenance costs and having an additional $250M savings impact on transmission pipelines. The objectives of the project included: (1) For PNNL staff to present technology to GRI and PSF staff on non- destructive evaluation, robotics, ground penetrating radar, and risk based inspection guidelines for application to the operation and maintenance of natural gas pipelines. (2) For GRI and PSF staff to discuss with PNNL staff opportunities for improving the industrial competitiveness of operation and maintenance services. (3) To explore the basis for partnership with GRI and PSF staff on technology transfer topics. In this project, staff exchanges were conducted to GRI`s Pipeline Simulation Facility and to VPSI. PNNL . staff had access to the $10M GRI Pipeline Simulation Facility (PSF) at West Jefferson, Ohio. The facility has a 4,700-ft. long pipe loop, an NDE laboratory, and a data analysis laboratory. PNNL staff had access to the VPSI`s facility in Houston, TX. VPSI has developed some of the most sophisticated inspection tools currently used in the pipeline inspection industry.

  20. Preventing Clinical Leakage of Colonic Anastomoses with A Fibrin-Coated Collagen Patch Sealing - An Experimental Study

    Directory of Open Access Journals (Sweden)

    Tyge Nordentoft

    2014-08-01

    Conclusion: A collagen patch coated with fibrin glue components efficiently seals leaking gastrointestinal anastomoses in pigs. Whether these results may be applied to humans in order to prevent clinical anastomotic dehiscence must be investigated in future randomized clinical studies. [Arch Clin Exp Surg 2014; 3(4.000: 201-206

  1. [Clinical effects of pedicled omentum covering and wrapping the ureteral anastomosis to prevent ureteral anastomotic leakage after surgery of abdominal and pelvic tumors].

    Science.gov (United States)

    Wang, Gangcheng; Han, Guangsen; Ren, Yingkun; Cheng, Yong; Xu, Yongchao; Zhao, Yuzhou; Zhang, Jian; Lu, Chaomin

    2014-03-01

    To explore the clinical effects of pedicled omentum covering and wrapping the ureteral anastomosis to prevent ureteral anastomotic leakage after surgery of abdominal and pelvic tumors. Clinical data of 64 patients with ureteral anastomosis after surgery of abdominal and pelvic tumors treated in our department from May 2005 to May 2012 were retrospectively analyzed. They were assigned into 2 groups. There were 23 patients of ureteral anastomosis combined with pedicled omentum surrounding and wrapping the anastomotic site (optimization group), and 41 cases of ureteral anastomosis alone (control group). The clinical data of all the 64 patients were reviewed and the therapeutic effects of the two treatment approaches were compared. At one week after the operation, there were 8 cases (34.8%, 8/23) with ureteral anastomotic fistula in the optimization group and 31 cases (75.6%, 31/41) in the control group (P = 0.010). In the postoperative days 1-3, the average drainage everyday from abdominal tube around the anastomotic site was 260.4 ml and 320.8 ml, respectively (P = 0.446). The average drainage volume everyday was 80.5 ml and 160.5 ml from the postoperative day 4 to day 7 (P = 0.015). The average time of removal of the peritoneal cavity drainage tube was 18.5 d in the optimization group and 32.6 d postoperatively in the control group (P = 0.015). Covering and wrapping the ureteral anastomosis with pedicled omentum can promote the rapid adhesion of surrounding tissues to reduce urine leakage and postoperative complications, and shorten the surgical treatment cycle.

  2. Oil and Gas Production Wastewater: Soil Contamination and Pollution Prevention

    Directory of Open Access Journals (Sweden)

    John Pichtel

    2016-01-01

    Full Text Available During oil and natural gas production, so-called “produced water” comprises the largest byproduct stream. In addition, many oil and gas operations are augmented via injection of hydraulic fracturing (HF fluids into the formation. Both produced water and HF fluids may contain hundreds of individual chemicals, some known to be detrimental to public health and the environment. Oil and gas production wastewater may serve a range of beneficial purposes, particularly in arid regions, if managed correctly. Numerous treatment technologies have been developed that allow for injection, discharge to the land surface, or beneficial reuse. Although many papers have addressed the effects of oil and gas production wastewater (OGPW on groundwater and surface water quality, significantly less information is available on the effects of these fluids on the soil resource. This review paper compiles fundamental information on numerous chemicals used and produced during oil and gas development and their effects on the soil environment. Additionally, pollution prevention technologies relating to OGPW are presented. An understanding of the effects of OGPW on soil chemical, physical, and biological properties can provide a foundation for effective remediation of OGPW-affected soils; additionally, sustainable reuse of oil and gas water for irrigation and industrial purposes may be enhanced.

  3. Conceptual Design of Portable Filtered Air Suction Systems For Prevention of Released Radioactive Gas under Severe Accidents of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Yim, Man S.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    It becomes evident that severe accidents may occur by unexpected disasters such as tsunami, heavy flood, or terror. Once radioactive material is released from NPP through severe accidents, there are no ways to prevent the released radioactive gas spreading in the air. As a remedy for this problem, the idea on the portable filtered air suction system (PoFASS) for the prevention of released radioactive gas under severe accidents was proposed. In this paper, the conceptual design of a PoFASS focusing on the number of robot fingers and robot arm rods are proposed. In order to design a flexible robot suction nozzle, mathematical models for the gaps which represent the lifted heights of extensible covers for given convex shapes of pipes and for the covered areas are developed. In addition, the system requirements for the design of the robot arms of PoFASS are proposed, which determine the accessible range of leakage points of released radioactive gas. In this paper, the conceptual designs of the flexible robot suction nozzle and robot arm have been conducted. As a result, the minimum number of robot fingers and robot arm rods are defined to be four and three, respectively. For further works, extensible cover designs on the flexible robot suction nozzle and the application of the PoFASS to the inside of NPP should be studied because the radioactive gas may be released from connection pipes between the containment building and auxiliary buildings.

  4. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  5. Nitrite therapy prevents chlorine gas toxicity in rabbits.

    Science.gov (United States)

    Honavar, Jaideep; Doran, Stephen; Ricart, Karina; Matalon, Sadis; Patel, Rakesh P

    2017-04-05

    Chlorine (Cl 2 ) gas exposure and toxicity remains a concern in military and industrial sectors. While post-Cl 2 exposure damage to the lungs and other tissues has been documented and major underlying mechanisms elucidated, no targeted therapeutics that are effective when administered post-exposure, and which are amenable to mass-casualty scenarios have been developed. Our recent studies show nitrite administered by intramuscular (IM) injection post-Cl 2 exposure is effective in preventing acute lung injury and improving survival in rodent models. Our goal in this study was to develop a rabbit model of Cl 2 toxicity and test whether nitrite affords protection in a non-rodent model. Exposure of New Zealand White rabbits to Cl 2 gas (600ppm, 45min) caused significant increases in protein and neutrophil accumulation in the airways and ∼35% mortality over 18h. Nitrite administered 30min post Cl 2 exposure by a single IM injection, at 1mg/kg or 10mg/kg, prevented indices of acute lung injury at 6h by up to 50%. Moreover, all rabbits that received nitrite survived over the study period. These data provide further rationale for developing nitrite as post-exposure therapeutic to mitigate against Cl 2 gas exposure injury. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. STUDY 1......, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim...... of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme...

  7. Preventing Instability Phenomenon in Gas-lift Optimization

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Mahdiani

    2015-01-01

    Full Text Available One of the problems that sometimes occur in gas allocation optimization is instability phenomenon. This phenomenon reduces the oil production and damages downhole and surface facilities. Different works have studied the stability and suggested some solutions to override it, but most of them (such as making the well intelligent are very expensive and thus they are not applicable to many cases. In this paper, as a new approach, the stability has been studied in gas allocation optimization problems. To prevent the instability, instability has been assumed as a constraint for the optimizer and then the optimizer has been run. For the optimization, first a genetic algorithm and then a hybrid of genetic algorithm and Newton-Quasi have been used, and their results are compared to ensure the good performance of the optimizer; afterwards, the effect of adding the instability constraint to the problem on production reduction have been discussed. The results show that the production loss with adding this constraint to the system is very small and this method does not need any additional and expensive facilities for preventing the instability. Therefore, the new method is applicable to different problems.

  8. Acoustic detection of seabed gas leaks, with application to Carbon Capture and Storage (CCS), and leak prevention for the oil and gas industry

    OpenAIRE

    Berges, B.J.P.

    2015-01-01

    The acoustic remote sensing of subsea gas leakage, applied to the monitoring of underwater gas discharges from anthropogenic and natural sources, is becoming increasingly important. First, as the oil and gas industry is facing increasing regulation, there is a need to put more control in the industrial process and to assess the impact on the marine environment. The applications are diverse, including: early warnings of "blow-out" from offshore installations, detection of leaks from underwater...

  9. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  10. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  11. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  12. Intraspinal Leakage of Cement During Vertebroplasty for an Elderly Woman with Osteoporotic Burst Fracture: A Case Report and Short Review of Prevention and Management

    Directory of Open Access Journals (Sweden)

    Yuk-Chuen Siu

    2015-12-01

    Full Text Available Osteoporotic spine fracture is very common nowadays due to the aging population. It may result in prolonged immobilization due to significant back pain. Cement vertebroplasty helps to relieve pain, provides immediate stability and allows early mobilization. Intraspinal leakage of cement is a rare complication but it may lead to catastrophic neurological injuries. Evidence-based management guidelines for this complication are lacking. This is a case report about intraspinal leakage of cement during vertebroplasty for an 85-year-old woman with osteoporotic burst fractures over the lumbar spine. Urgent exploration and decompression was performed. No neurological injury was found after the operation and the patient recovered from osteoporotic back pain uneventfully.

  13. Application of resin lining system for countermeasures for preventing leakage from openings in low temperature materials storage; Teion busshitsu chozoji no ekimore oyobi reiki more taisaku toshite no kobunshikei zairyo no tekiyosei

    Energy Technology Data Exchange (ETDEWEB)

    Inada, Y. [Ehime Univ., Ehime (Japan). Faculty of Engineering; Seki, S.

    1996-12-21

    Recently, many of the low temperature materials such as LNG and LPG used as an energy substitution for petroleum were stored in the reclaimed land of the sea side district, however, it is necessary for those storage methods to enlarge sites. Therefore, it was considered to directly store the low temperature materials in openings excavated in the rock mountains. However, countermeasures for leakage of liquid and cold gas from cracks in openings would be an important subject. In this study, as a countermeasure for leakage of liquid and cold gas in the case in which low temperature materials were stored in openings in the rock mountains, the lining of resin materials on the surface of openings was proposed. Characteristics of strength and deformation and values of the thermal physical properties for the resin materials at the low temperature were obtained by experiments. This material was compared with granite supposed as a parent rock, and the thermal property of the resin materials was understood. Next, an analysis was conducted in the case of using the resin materials as a lining, the behavior of the surrounding rocks of the openings and the stability of the lining were investigated. 17 refs., 25 figs., 2 tabs.

  14. Accidental Bowel Leakage

    Science.gov (United States)

    ... nerve stimulation, injections, and surgery. What types of lifestyle changes can help treat accidental bowel leakage? Having ... Journal Clinical Updates Practice Management Coding Health Info Technology Professional Liability Managing Your Practice Patient Safety & Quality ...

  15. Pressure Gauges Monitor Leakage Past Seals

    Science.gov (United States)

    Smith, Steven A.

    1990-01-01

    Method devised to measure leakage of gas past each of two sets of primary and secondary seals into common volume from which aggregate flow measured. Although method applicable only to specific combination of flow configuration and thermal conditions, it serves as example of more general approach involving use of statistical analysis to extract additional information from measurements.

  16. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  17. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  18. How to prevent greenhouse gas emissions in electrical installations: lighting energy savings and solar energy approaches

    International Nuclear Information System (INIS)

    Yavuz, C.; Aksoy, C.

    2012-01-01

    Day by day greenhouse gas emissions increase dramatically. A passive adaptive method of lighting energy savings, daylight responsive systems are considered one of the best solutions for energy efficiency, saving and prevent CO 2 emissions. Results of an annual experiment which was held in Sakarya University proves the necessity of daylight responsive systems with a 41% energy saving and 942.5 kg of prevented CO 2 emissions Thinking this prevention is realized just only in a 36 m 2 room with the use of 8 luminaries spreading such systems to nationwide, a major amount of greenhouse gas emissions would be prohibited. On the other hand energy saving is not the only way to reduce CO 2 emissions. Again in Sakarya University a project has started to investigate the possibility of illumination of a complete building by using solar energy. This paper evaluates these mentioned systems both in energy efficiency, greenhouse gas emissions prevention and economic point of views. (author)

  19. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  20. Study on Acoustic Catheter of Boiler Tube Leakage Monitoring Systems

    Science.gov (United States)

    Lv, Yongxing; Feng, Qiang

    Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system.

  1. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  2. Improvement of a yeast self-excising integrative vector by prevention of expression leakage of the intronated Cre recombinase gene during plasmid maintenance in Escherichia coli.

    Science.gov (United States)

    Agaphonov, Michael O

    2017-12-01

    The use of plasmids possessing a regulatable gene coding for a site-specific recombinase together with its recognition sequences significantly facilitates genome manipulations since it allows self-excision of the portion of the genetic construct integrated into the host genome. Stable maintenance of such plasmids in Escherichia coli, which is used for plasmid preparation, requires prevention of recombinase synthesis in this host, which can be achieved by interrupting the recombinase gene with an intron. Based on this approach, Saccharomyces cerevisiae and Hansenula polymorpha self-excising vectors possessing intronated gene for Cre recombinase and its recognition sites (LoxP) were previously constructed. However, this work shows instability of the H. polymorpha vectors during plasmid maintenance in E. coli cells. This could be due to recombination between the loxP sites caused by residual expression of the cre gene. Prevention of translation reinitiation on an internal methionine codon completely solved this problem. A similar modification was made in a self-excising vector designed for S. cerevisiae. Apart from substantial improvement of yeast self-excising vectors, the obtained results also narrow down the essential part of Cre sequence. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Risk of Leakage versus Depth of Injection in Geological Storage

    OpenAIRE

    Celia, Michael A.; Nordbotten, Jan Martin; Bachu, Stefan; Dobossy, Mark E.; Court, Benjamin

    2009-01-01

    One of the outstanding challenges for large-scale CCS operations is to develop reliable quantitative risk assessments with a focus on leakage of both injected CO2 and displaced brine. A critical leakage pathway is associated with the century-long legacy of oil and gas exploration and production, which has led to many millions of wells being drilled. Many of those wells are in locations that would otherwise be excellent candidates for CCS operations, especially across many parts of North Ameri...

  4. Gas migration from closed coal mines to the surface. Risk assessment methodology and prevention means

    International Nuclear Information System (INIS)

    Pokryszka, Z.; Tauziede, Ch.; Lagny, C.; Guise, Y.; Gobillot, R.; Planchenault, J.M.; Lagarde, R.

    2005-01-01

    French law as regards renunciation to mining concessions calls for the mining operator to first undertake analyses of the risks represented by their underground mining works. The problem of gas migration to the surface is especially significant in the context of coal mines. This is because mine gas can migrate to the earth's surface, then present significant risks: explosion, suffocation or gas poisoning risks. As part of the scheduled closure of all coal mining operations in France, INERIS has drawn up, at the request of national mining operator Charbonnages de France, a general methodology for assessing the risk linked to gas in the context of closed coal mines. This article presents the principles of this methodology. An application example based on a true case study is then described. This is completed by a presentation of the preventive and monitoring resources recommended and usually applied in order to manage the risk linked to gaseous emissions. (authors)

  5. Multifamily Envelope Leakage Model

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, Omari [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Griffiths, Dianne [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-05-08

    “The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deter program participants, and dissuade them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.” This statement found in a 2012 report by Heschong Mahone Group for several California interests emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing—the more appropriate test for assessing energy savings opportunities—could easily be six times that, and that’s only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. This research seeks to provide an algorithm for predicting the guarded blower door test result based upon a single, total blower door test.

  6. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  7. Duct Leakage Repeatability Testing

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  8. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  9. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  10. Modelling of Consequences of Biogas Leakage from Gasholder

    Directory of Open Access Journals (Sweden)

    Petr Trávníček

    2017-03-01

    Full Text Available This paper describes modelling of consequences of biogas leakage from a gasholder on agricultural biogas station. Four scenarios were selected for the purpose of this work. A rupture of gasholders membrane and instantaneous explosion of gas cloud, blast of gas with delay, emptying of whole volume of gas (without initiation and initiation of gas with Jet-Fire. Leakage of gas is modelled by special software and consequences are determined on the basis of results. The first scenario was modelled with help of equations because used software does not include an appropriate model. A farm with high building density was chosen as a model case. Biogas is replaced by methane because used software does not support modelling of dispersion of mixtures. From this viewpoint, a conservative approach is applied because biogas contains “only” approximately 60% of methane (in dependence on technology and processed material.

  11. Temperature and voltage responses of a molten carbonate fuel cell in the presence of a hydrogen fuel leakage

    International Nuclear Information System (INIS)

    Law, M C; Wee, S K; Liang, G V Y; Lee, V C C

    2015-01-01

    A two dimensional (2-D), dynamic model of a molten carbonate fuel cell (MCFC) was developed using COMSOL Multi-physics. The model was used to investigate the dynamic behaviour of the MCFC in the presence of hydrogen fuel leakage. A leakage was modelled as a known outflow velocity at the anode gas channel. The effects of leakage velocity and the leakage location were investigated. The simulations show that anode electrode temperature increases as the leakage velocity increases. The voltage generated is shown to decrease at the start of the leakage occurrence due to loss of hydrogen gas. Later the voltage increases as the anode temperature increases. The results also show that the changes of temperature and voltage are more significant if a leakage occurs nearer to the inlet compared to that at the outlet of anode gas channel. (paper)

  12. Notification determining technical standards concerning prevention of radiation injuries by electron capture detectors for gas chromatography

    International Nuclear Information System (INIS)

    1981-01-01

    This rule is established under the provisions of the law on the prevention of radiation injuries by radioisotopes, the ordinance and the regulation for the execution of the law. This rule is applied to electron capture detectors for gas chromatography under the law. Basic terms are defined, such as detector radiation source, detector container and carrier gas. The detectors shall consist of detector radiation sources and containers, and the containers must be such that the radiation sources can not be easily taken away and never cause the danger to fall off. The induction and discharge mouths of the detector containers shall be shut tightly with caps, etc. The main structures and radiation sources of detectors shall be made of materials, which are difficult to corrode, and do not melt and easily cause chemical change below 800 deg. C. Detector radiation sources shall be made of metals plated with nickel 63 less than 20 milli-curie. The radiation dose rate on the surface of a detector shall be shielded to less than 0.06 milli-rem an hour. The temperature of detectors and carrier gas shall not exceed 350 deg. C. Corrosive gas shall not be used as carrier gas. The period of effective indication is 5 years. The method of washing, and the conditions of leak, heat-resistance and shock-resistance examinations are defined, respectively. (Okada, K.)

  13. Leakage limits for inflatable seals of sodium cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Sinha, N.K.; Raj, Baldev

    2014-01-01

    Highlights: • All possible types/modes of gas escape covered. • Limits include simultaneous contributions from bypass and permeation leakage modes. • Leakage of radioactive cover gas with fission products assumed. • Possibility of sodium frost deposition in sealed gap considered. • Cover gas activity decay during fuel handling and relative importance of types/modes of leakage considered for realistic results and simpler seal design. -- Abstract: Estimation and stipulation of allowable leakage for inflatable seals of 500 MWe Prototype Fast Breeder Reactor is depicted. Leakage limits are specified using a conservative approach, which assumes escape of radioactive cover gas with fission products across the seals in bypass and permeation modes and possibility of sodium frost deposition in sealed gaps because of permeation leakage of inflation gas. Procedures to arrive at the allowable leakages of argon cover gas (normal-operation/fuel-handling: 10 −3 /10 −2 scc/s/m length of seal) and argon inflation gas (10 −3 scc/s/m length of seal) is described

  14. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology

    OpenAIRE

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective...

  15. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  16. Applications to marine disaster prevention spilled oil and gas tracking buoy system

    CERN Document Server

    2017-01-01

    This book focuses on the recent results of the research project funded by a Grant-in-Aid for Scientific Research (S) of the Japan Society for the Promotion of Science (No. 23226017) from FY 2011 to FY 2015 on an autonomous spilled oil and gas tracking buoy system and its applications to marine disaster prevention systems from a scientific point of view. This book spotlights research on marine disaster prevention systems related to incidents involving oil tankers and offshore platforms, approaching these problems from new scientific and technological perspectives. The most essential aspect of this book is the development of a deep-sea underwater robot for real-time monitoring of blowout behavior of oil and gas from the seabed and of a new type of autonomous surface vehicle for real-time tracking and monitoring of oil spill spread and drift on the sea surface using an oil sensor. The mission of these robots is to provide the simulation models for gas and oil blowouts or spilled oil drifting on the sea surface w...

  17. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... following minimum requirements: (1) A leakage survey with leak detector equipment must be conducted in business districts, including tests of the atmosphere in gas, electric, telephone, sewer, and water system... survey with leak detector equipment must be conducted outside business districts as frequently as...

  18. Safety barriers on oil and gas platforms. Means to prevent hydrocarbon releases

    Energy Technology Data Exchange (ETDEWEB)

    Sklet, Snorre

    2005-12-15

    The main objective of the PhD project has been to develop concepts and methods that can be used to define, illustrate, analyse, and improve safety barriers in the operational phase of offshore oil and gas production platforms. The main contributions of this thesis are; Clarification of the term safety barrier with respect to definitions, classification, and relevant attributes for analysis of barrier performance Development and discussion of a representative set of hydrocarbon release scenarios Development and testing of a new method, BORA-Release, for qualitative and quantitative risk analysis of hydrocarbon releases Safety barriers are defined as physical and/or non-physical means planned to prevent, control, or mitigate undesired events or accidents. The means may range from a single technical unit or human actions, to a complex socio-technical system. It is useful to distinguish between barrier functions and barrier systems. Barrier functions describe the purpose of safety barriers or what the safety barriers shall do in order to prevent, control, or mitigate undesired events or accidents. Barrier systems describe how a barrier function is realized or executed. If the barrier system is functioning, the barrier function is performed. If a barrier function is performed successfully, it should have a direct and significant effect on the occurrence and/or consequences of an undesired event or accident. It is recommended to address the following attributes to characterize the performance of safety barriers; a) functionality/effectiveness, b) reliability/ availability, c) response time, d) robustness, and e) triggering event or condition. For some types of barriers, not all the attributes are relevant or necessary in order to describe the barrier performance. The presented hydrocarbon release scenarios include initiating events, barrier functions introduced to prevent hydrocarbon releases, and barrier systems realizing the barrier functions. Both technical and human

  19. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    Science.gov (United States)

    White, Curt [Pittsburgh, PA; Wells, Arthur [Bridgeville, PA; Diehl, J Rodney [Pittsburgh, PA; Strazisar, Brian [Venetia, PA

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  20. [Leakage from the connecting portion between the anesthesia machine and vaporizer].

    Science.gov (United States)

    Murata, Yuya; Takahashi, Hiroshi; Tokuwaka, Junko; Tanaka, Makoto

    2013-12-01

    We recently encountered three cases of the leakage from the connecting portion of sevoflurane vaporizer in Fabius Tiro produced by Drager company, and in one case of those, oxygen saturation decreased. The connecting portion had leakage merely in the contact with the fixture of the monitor, because of the structure easily displaced by an external force. Further, it was difficult to detect the leakage due to the ability to correct the insufficient supply of fresh gas by taking in air. We hope a reform of the connecting portion and an alarm to inform it if the anesthesia machine detects the leakage.

  1. A study of leakage rates through mine seals in underground coal mines.

    Science.gov (United States)

    Schatzel, Steven J; Krog, Robert B; Mazzella, Andrew; Hollerich, Cynthia; Rubinstein, Elaine

    2015-04-07

    The National Institute for Occupational Safety and Health conducted a study on leakage rates through underground coal mine seals. Leakage rates of coal bed gas into active workings have not been well established. New seal construction standards have exacerbated the knowledge gap in our understanding of how well these seals isolate active workings near a seal line. At a western US underground coal mine, we determined seal leakage rates ranged from about 0 to 0.036 m 3 /s for seven 340 kPa seals. The seal leakage rate varied in essentially a linear manner with variations in head pressure at the mine seals.

  2. Low leakage mechanical joint development

    International Nuclear Information System (INIS)

    Crago, W.A.

    1976-01-01

    As a consequence of the development programs described, certain recommendatons for design of mechanial joints have been proposed. These include: 1. Spiral wound gaskets filled with chrysotile asbestos are adequate for primary heat transport system fluid conditions. 2. Spiral wound gaskets should be seated under a stress of 110 to 125 MPa for low leakage performance. 3. Load maintenance, while perhaps reducing leakage, introduces more complex hardware, and is of unproven benefit. 4. Uniform circumferential load application requires the use of hydraulic stud tensioners to ensure satisfactory performance from large size mechanical joints. (author)

  3. Airbag for the closing of pipelines on explosions and leakages

    DEFF Research Database (Denmark)

    Eisenreich, N.; Neutz, J.; Seiler, F.

    2007-01-01

    This paper is a result of international effort aimed at the construction of a device for quick closing of pipelines in the case of explosion propagation and/or chemical leakage. Such a problem exists in industries where flammable substances are transported by pipelines. The basic solution principle...... was the idea to use airbags similar to those utilized in cars. Two pipeline applications were taken into consideration: a low-pressure module able to suppress explosion propagation and a high-pressure module to stop leakages from, e.g. natural gas pipeline capable to be used for duct diameters up to 0.6 m...

  4. Determining optimal preventive maintenance interval for component of Well Barrier Element in an Oil & Gas Company

    Science.gov (United States)

    Siswanto, A.; Kurniati, N.

    2018-04-01

    An oil and gas company has 2,268 oil and gas wells. Well Barrier Element (WBE) is installed in a well to protect human, prevent asset damage and minimize harm to the environment. The primary WBE component is Surface Controlled Subsurface Safety Valve (SCSSV). The secondary WBE component is Christmas Tree Valves that consist of four valves i.e. Lower Master Valve (LMV), Upper Master Valve (UMV), Swab Valve (SV) and Wing Valve (WV). Current practice on WBE Preventive Maintenance (PM) program is conducted by considering the suggested schedule as stated on manual. Corrective Maintenance (CM) program is conducted when the component fails unexpectedly. Both PM and CM need cost and may cause production loss. This paper attempts to analyze the failure data and reliability based on historical data. Optimal PM interval is determined in order to minimize the total cost of maintenance per unit time. The optimal PM interval for SCSSV is 730 days, LMV is 985 days, UMV is 910 days, SV is 900 days and WV is 780 days. In average of all components, the cost reduction by implementing the suggested interval is 52%, while the reliability is improved by 4% and the availability is increased by 5%.

  5. Prevented Mortality and Greenhouse Gas Emissions From Historical and Projected Nuclear Power

    Science.gov (United States)

    Kharecha, Pushker A.; Hansen, James E.

    2013-01-01

    In the aftermath of the March 2011 accident at Japan's Fukushima Daiichi nuclear power plant, the future contribution of nuclear power to the global energy supply has become somewhat uncertain. Because nuclear power is an abundant, low-carbon source of base-load power, it could make a large contribution to mitigation of global climate change and air pollution. Using historical production data, we calculate that global nuclear power has prevented an average of 1.84 million air pollution-related deaths and 64 gigatonnes of CO2-equivalent (GtCO2-eq) greenhouse gas (GHG) emissions that would have resulted from fossil fuel burning. On the basis of global projection data that take into account the effects of the Fukushima accident, we find that nuclear power could additionally prevent an average of 420 000-7.04 million deaths and 80-240 GtCO2-eq emissions due to fossil fuels by midcentury, depending on which fuel it replaces. By contrast, we assess that large-scale expansion of unconstrained natural gas use would not mitigate the climate problem and would cause far more deaths than expansion of nuclear power.

  6. Suggestions to leak prevention in Fortaleza's natural gas piping system; Sugestoes para a prevencao de vazamentos de gas natural canalizado na regiao metropolitana de Fortaleza

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Marcus de Barros [Agencia Reguladora de Servicos Publicos Delegados do Estado do Ceara (ARCE), Fortaleza, CE (Brazil)

    2004-07-01

    Leaks are the bigger problem in health, safety and environmental when the subject is gas distribution piping systems. Specially in high density human regions, like in the majority districts of Fortaleza, safety have to be the higher priority to the gas company responsible for the gas distribution piping systems. Leaks are able to cause accidents or incidents, depending on the circumstances which they happen. In order to be control the situation and overcome the luck factor, leaks must be previously avoided by the application of some security requirements. This paper present some suggestions to natural gas leak prevention in the Fortaleza's metropolitan region pipeline systems. First, the piping systems are analysed, observing the risk regions. Then, safety actions and basic requirements to avoid pipe corrosion are presented in order to improve safety in the gas distribution piping systems of Fortaleza's metropolitan region. (author)

  7. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ..., Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying High Efficiency Respirators and Combination Gas Masks § 84.1150 Exhalation valve leakage test; minimum requirements. (a) Dry exhalation valves...

  8. Anastomotic leakage after anterior resection for rectal cancer: risk factors

    DEFF Research Database (Denmark)

    Bertelsen, C A; Andreasen, A H; Jørgensen, Torben

    2010-01-01

    OBJECTIVE: The study aimed to identify risk factors for clinical anastomotic leakage (AL) after anterior resection for rectal cancer in a consecutive national cohort. METHOD: All patients with an initial first diagnosis of colorectal adenocarcinoma were prospectively registered in a national......, smoking and perioperative bleeding. Faecal diversion is advisable after total mesorectal excision of low rectal tumours in order to prevent AL....

  9. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  10. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  11. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  12. Electrolyte leakage as an indicator

    Directory of Open Access Journals (Sweden)

    ahmad nezami

    2009-06-01

    Full Text Available In order to evaluate the electrolyte leakage as an indicator of freezing injury in colza (Brassica napus L. genotypes under controlled conditions, a trial carried out at the green house of College of Agriculture, Ferdowsi University of Mashhad. In this study 10 rapeseed genotypes, with 5 temperatures (0, -4, -8, -12 and -16 °C on subplot and acclimation and non acclimation on main plot were evaluated on RCD factorial split plot with two replications. Plants were kept until 3-5 leaf stage in green house condition with 23/16 2 °C (day/night and natural photoperiod. Pots were subjected to acclimation (for three weeks or non acclimation that plants immediately frozen.For acclimation treatment after three weeks freezing was done in thermogradient freezer. The cell membrane integrity was measured through electrolyte leakage and the lethal temperature 50 (LT50 of samples also were determined. There were significant differences (p

  13. Future Issues and Approaches to Health Monitoring and Failure Prevention for Oil-Free Gas Turbines

    Science.gov (United States)

    DellaCorte, Christopher

    2004-01-01

    Recent technology advances in foil air bearings, high temperature solid lubricants and computer based modeling has enabled the development of small Oil-Free gas turbines. These turbomachines are currently commercialized as small (<100 kW) microturbine generators and larger machines are being developed. Based upon these successes and the high potential payoffs offered by Oil-Free systems, NASA, industry, and other government entities are anticipating Oil-Free gas turbine propulsion systems to proliferate future markets. Since an Oil-Free engine has no oil system, traditional approaches to health monitoring and diagnostics, such as chip detection, oil analysis, and possibly vibration signature analyses (e.g., ball pass frequency) will be unavailable. As such, new approaches will need to be considered. These could include shaft orbit analyses, foil bearing temperature measurements, embedded wear sensors and start-up/coast down speed analysis. In addition, novel, as yet undeveloped techniques may emerge based upon concurrent developments in MEMS technology. This paper introduces Oil-Free technology, reviews the current state of the art and potential for future turbomachinery applications and discusses possible approaches to health monitoring, diagnostics and failure prevention.

  14. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology.

    Science.gov (United States)

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.

  15. Can we use near-miss reports for accident prevention? A study in the oil and gas industry in Denmark

    NARCIS (Netherlands)

    Rasmussen, H.B.; Drupsteen, L.; Dyreborg, J.

    2013-01-01

    Background: The oil and gas industry in the Danish sector of the North Sea has always focused on reducing work-related accidents. Over the years, accident rates have been reduced, and near-miss reporting has gained in importance, because it allows the industry to learn from experience and prevent

  16. Topological qubit design and leakage

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, R; Slingerland, J K, E-mail: robert.ainsworth@nuim.ie, E-mail: joost@thphys.nuim.ie [Department of Mathematical Physics, National University of Ireland Maynooth, Co. Kildare (Ireland)

    2011-06-15

    We examine how best to design qubits for use in topological quantum computation. These qubits are topological Hilbert spaces associated with small groups of anyons. Operations are performed on these by exchanging the anyons. One might argue that in order to have as many simple single-qubit operations as possible, the number of anyons per group should be maximized. However, we show that there is a maximal number of particles per qubit, namely 4, and more generally a maximal number of particles for qudits of dimension d. We also look at the possibility of having topological qubits for which one can perform two-qubit gates without leakage into non-computational states. It turns out that the requirement that all two-qubit gates are leakage free is very restrictive and this property can only be realized for two-qubit systems related to Ising-like anyon models, which do not allow for universal quantum computation by braiding. Our results follow directly from the representation theory of braid groups, which implies that they are valid for all anyon models. We also make some remarks about generalizations to other exchange groups.

  17. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  18. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... {\\em Leakage resilient oblivious transfer.} We present the first construction for 1-out-of-2 oblivious transfer with security against leakage of a constant fraction of the honest party's memory. Our protocol is based on the OT construction presented by Peikert et al.~\\cite{PeikertVW08}. \\item {\\em...... Leakage resilient Yao's Garbled Circuit~\\cite{Yao82}.} We provide the first general construction for secure two-party computation and show how to adapt the proof from~\\cite{LP09} of Yao's protocol into the leakage resilient setting. Our result holds for a restricted set of functions due to technicalities...

  19. FORUM: Indirect leakage leads to a failure of avoided loss biodiversity offsetting.

    Science.gov (United States)

    Moilanen, Atte; Laitila, Jussi

    2016-02-01

    Biodiversity offsetting has quickly gained political support all around the world. Avoided loss (averted risk) offsetting means compensation for ecological damage via averted loss of anticipated impacts through the removal of threatening processes in compensation areas.Leakage means the phenomenon of environmentally damaging activity relocating elsewhere after being stopped locally by avoided loss offsetting. Indirect leakage means that locally avoided losses displace to other administrative areas or spread around diffusely via market effects. Synthesis and applications . Indirect leakage can lead to high net biodiversity loss. It is difficult to measure or prevent, raising doubts about the value of avoided loss offsetting. Market demand for commodities is on the rise, following increasing human population size and per capita consumption, implying that indirect leakage will be a rule rather than an exception. Leakage should be accounted for when determining offset multipliers (ratios) even if multipliers become extremely high.

  20. Clinical practice guidelines for prevention, diagnosis and management of early and delayed-onset ocular injuries due to mustard gas exposure

    Directory of Open Access Journals (Sweden)

    Zhale Rajavi

    2017-01-01

    Conclusion: Considering the lack of CPGs for the prevention, diagnosis, and management of mustard gas-induced keratitis, these recommendations would be useful to prevent the serious ocular complications of mustard gas and standardize eye care services to the affected individuals.

  1. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    construction may already suffice to protect against realistic side-channel attacks. In this paper, we show that indeed for simpler constructions leakage-resilience can be obtained when we aim for relaxed security notions where the leakage-functions and/or the inputs to the primitive are chosen non......-adaptively. For example, we show that a three round Feistel network instantiated with a leakage resilient PRF yields a leakage resilient PRP if the inputs are chosen non-adaptively (This complements the result of Dodis and Pietrzak [CRYPTO’10] who show that if a adaptive queries are allowed, a superlogarithmic number...

  2. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  3. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  4. Generation and Measurement of Chlorine Dioxide Gas at Extremely Low Concentrations in a Living Room: Implications for Preventing Airborne Microbial Infectious Diseases.

    Science.gov (United States)

    Ogata, Norio; Sogawa, Koushirou; Takigawa, Yasuhiro; Shibata, Takashi

    2017-01-01

    Preventing respiratory diseases caused by airborne microbes in enclosed spaces is still not satisfactorily controlled. At extremely low concentrations (about 30 parts per billion), chlorine dioxide (ClO2) gas can inactivate airborne microbes and prevent respiratory disease. It has no toxic effect on animals at this level. However, controversies still remain regarding how to measure concentrations of ClO2 gas at such low levels. It is therefore necessary to prove that measured gas concentrations are accurate and reproducible. ClO2 gas was released from a gas generator and its concentration was measured by a novel highly sensitive gas analyzer. We compared its data with those from ion chromatography. We demonstrate that the gas concentrations measured in a room using the gas analyzer are accurate and reproducible after comparing the results with those from ion chromatography. However, the temperature dependence of the gas analyzer was found. Therefore, data correction is required for each temperature at which gas concentration is measured. A theoretical analysis of the gas concentrations predicted by the rate of ClO2 gas released from the ClO2 generator was also performed. Our results advance progress toward using low concentration ClO2 gas to prevent airborne infectious diseases such as influenza. © 2016 S. Karger AG, Basel.

  5. Gas

    International Nuclear Information System (INIS)

    1996-01-01

    The French government has decided to modify the conditions of extension of local natural gas authorities to neighbouring districts. The European Union is studying the conditions of internal gas market with the objective of more open markets although considering public service requirements

  6. Static Gas-Charging Plug

    Science.gov (United States)

    Indoe, William

    2012-01-01

    A gas-charging plug can be easily analyzed for random vibration. The design features two steeped O-rings in a radial configuration at two different diameters, with a 0.050-in. (.1.3-mm) diameter through-hole between the two O-rings. In the charging state, the top O-ring is engaged and sealing. The bottom O-ring outer diameter is not squeezed, and allows air to flow by it into the tank. The inner diameter is stretched to plug the gland diameter, and is restrained by the O-ring groove. The charging port bushing provides mechanical stop to restrain the plug during gas charge removal. It also prevents the plug from becoming a projectile when removing gas charge from the accumulator. The plug can easily be verified after installation to ensure leakage requirements are met.

  7. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  8. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice of inform...... and non-timed attacks on the Onion Routing protocol....

  9. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O.; Arena, L.; Griffiths, D.

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  10. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  11. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied......: (i) in each observation the leakage is bounded, (ii) different parts of the computation leak independently, and (iii) the randomness that is used for certain operations comes from a simple (non-uniform) distribution. In contrast to earlier work on leakage resilient circuit compilers, which relied...

  12. Choosing the best animal species to mimic clinical colon anastomotic leakage in humans: a qualitative systematic review

    DEFF Research Database (Denmark)

    Pommergaard, H C; Rosenberg, J; Schumacher-Petersen, Camilla

    2011-01-01

    Animal models are valuable for studying pathogenic factors and preventive measures for colon anastomotic leakage. The suitability of the species as models varies greatly; however, no consensus exists on which species to use. The aim of this review was to evaluate different experimental animals...... for the study of clinical colon anastomotic leakage....

  13. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  14. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  15. Prevention

    Science.gov (United States)

    ... Error processing SSI file About Heart Disease & Stroke Prevention Heart disease and stroke are an epidemic in ... secondhand smoke. Barriers to Effective Heart Disease & Stroke Prevention Many people with key risk factors for heart ...

  16. Leakage detection algorithm integrating water distribution networks hydraulic model

    CSIR Research Space (South Africa)

    Adedeji, K

    2017-06-01

    Full Text Available and estimation is vital for effective water service. For effective detection of background leakages, a hydraulic analysis of flow characteristics in water piping networks is indispensable for appraising such type of leakage. A leakage detection algorithm...

  17. New Belgian position on containment leakage testing

    International Nuclear Information System (INIS)

    De Boeck, B.

    1986-01-01

    The containment leakage testing requirements (up to now 10 CFR 50 App. J) have recently been reevaluated in Belgium. The criterion for type A tests at half the accident pressure has been strengthened, but the periodicity has been relaxed. New overall leakage test at very low overpressure have been required after each extended cold shutdown period. A few items of the procedure for type A tests have been modified. It is felt that the new requirements improve the safety but also lower the burden of the containment leakage tests. Experimental results from tests performed in 1985 at Tihange reactor and Doel unit 3 are presented

  18. Hyperbaric oxygen therapy for the prevention of arterial gas embolism in food grade hydrogen peroxide ingestion.

    Science.gov (United States)

    Hendriksen, Stephen M; Menth, Nicholas L; Westgard, Bjorn C; Cole, Jon B; Walter, Joseph W; Masters, Thomas C; Logue, Christopher J

    2017-05-01

    Food grade hydrogen peroxide ingestion is a relatively rare presentation to the emergency department. There are no defined guidelines at this time regarding the treatment of such exposures, and providers may not be familiar with the potential complications associated with high concentration hydrogen peroxide ingestions. In this case series, we describe four patients who consumed 35% hydrogen peroxide, presented to the emergency department, and were treated with hyperbaric oxygen therapy. Two of the four patients were critically ill requiring intubation. All four patients had evidence on CT or ultrasound of venous gas emboli and intubated patients were treated as if they had an arterial gas embolism since an exam could not be followed. After hyperbaric oxygen therapy each patient was discharged from the hospital neurologically intact with no other associated organ injuries related to vascular gas emboli. Hyperbaric oxygen therapy is an effective treatment for patients with vascular gas emboli after high concentration hydrogen peroxide ingestion. It is the treatment of choice for any impending, suspected, or diagnosed arterial gas embolism. Further research is needed to determine which patients with portal venous gas emboli should be treated with hyperbaric oxygen therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Numerical studies of CO2 and brine leakage into a shallow aquifer through an open wellbore

    Science.gov (United States)

    Wang, Jingrui; Hu, Litang; Pan, Lehua; Zhang, Keni

    2018-03-01

    Industrial-scale geological storage of CO2 in saline aquifers may cause CO2 and brine leakage from abandoned wells into shallow fresh aquifers. This leakage problem involves the flow dynamics in both the wellbore and the storage reservoir. T2Well/ECO2N, a coupled wellbore-reservoir flow simulator, was used to analyze CO2 and brine leakage under different conditions with a hypothetical simulation model in water-CO2-brine systems. Parametric studies on CO2 and brine leakage, including the salinity, excess pore pressure (EPP) and initially dissolved CO2 mass fraction, are conducted to understand the mechanism of CO2 migration. The results show that brine leakage rates increase proportionally with EPP and inversely with the salinity when EPP varies from 0.5 to 1.5 MPa; however, there is no CO2 leakage into the shallow freshwater aquifer if EPP is less than 0.5 MPa. The dissolved CO2 mass fraction shows an important influence on the CO2 plume, as part of the dissolved CO2 becomes a free phase. Scenario simulation shows that the gas lifting effect will significantly increase the brine leakage rate into the shallow freshwater aquifer under the scenario of 3.89% dissolved CO2 mass fraction. The equivalent porous media (EPM) approach used to model the wellbore flow has been evaluated and results show that the EPM approach could either under- or over-estimate brine leakage rates under most scenarios. The discrepancies become more significant if a free CO2 phase evolves. Therefore, a model that can correctly describe the complex flow dynamics in the wellbore is necessary for investigating the leakage problems.

  20. Experimental investigation on air leakage characteristics of containments

    International Nuclear Information System (INIS)

    Hyungtae Kim; Namso Cho; Youngsun Choun; Namsik Kim

    2005-01-01

    Facilities such as nuclear power plants have containments as atomic reactor which are subjected to high internal pressure. The internal pressure induces tensile stress in the containments. The tensile stress can cause generation and propagation of cracks through which the gas contaminated radioactively may leak. Supposing that a potential leakage accident happened, an experimental study on air leakage characteristics of containments was carried out. Two reinforced concrete specimens which reflect a wall of the containment were manufactured. Then the specimens were subjected to tensile load to generate cracks and air penetration tests were performed. During the air leakage test, the air pressure of inlet and outlet, the flow rate of outlet and the sum of crack widths were measured. The individual factors of the specific crack shape, the wall roughness and the flow coefficient, could be estimated from these experimental data. The factors are expressed as functions in terms of the sum of crack widths by regression analysis. The measured flow rates were compared with the predictive values obtained using the regression curves. Then flow rates according to pressure gradient and crack width were estimated. It was verified that the predicted flow rates agree with the measured flow rates statistically, that is, the estimated functions predicting the wall roughness and the flow coefficient are suitable. Once the sum of crack widths and inlet pressure of concrete wall are known, thus, the air flow rate can be predicted. The relationship among crack width, pressure and flow rate will serve as a criterion for air leakage characteristics of containments. (authors)

  1. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  2. Fiscal 1999 basic survey report for promotion of joint implementation. Feasibility study for rehabilitation and optimization of pipelines for reduction of greenhouse gas emission; 1999 nendo onshitsu koka gas haishutsu sakugen no tame no pipeline no rihabiri, saitekika no tame no F/S chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    A survey is conducted of the actual state of leaks from natural gas pipelines and of the energy-saving and greenhouse gas-reducing effects of pipeline rehabilitation, with the clean development mechanism (CDM) borne in mind. Comilla and Chittagong are the areas that are covered by the survey. Natural gas leaks from the main pipelines BC and BD are calculated to be 5,300 and 5,600 tons/year, respectively. Total leakage across the country is estimated at 85,000 tons/year. Approximately 41% of the imbalance is explained by leakage while the rest is attributable to errors in gas flow measurement etc. The total leakage from branch pipelines is approximately three times larger than that from main pipelines, and some measures need to be taken to remedy the situation. For the densely populated city of Dhaka which finds itself in a network of branch pipelines, in particular, rehabilitation and optimization of its accessory power stations etc. are quite important. Measures for leakage if properly implemented will not only reduce the amount of leakage but also prevent ignition or explosion for the minimization of economic loss and for the assurance of safety. Error-free gas flow measurement if realized will strengthen the foundation on which sales are performed. (NEDO)

  3. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    Science.gov (United States)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  4. Ray-leakage-free discal solar concentrators of a novel design

    Science.gov (United States)

    Yin, Peng; Xu, Xiping; Jiang, Zhaoguo; Hai, Yina

    2017-12-01

    For high concentration ratio of the planar concentrator which is mainly used for photovoltaic or solar-thermal applications, the ray-leakage must be prevented during rays propagated in the lightguide. In this paper, the design of a ray-leakage-free discal solar concentrator is proposed which provides a high concentration ratio while acquiring a high optical efficiency. The design structure of the coupling structure is a straightforward hemisphere instead of complicated structure in other concentrators because the emergent rays from the hybrid collectors have any tilt angle, which prompts the ray-leakage-free propagating length can be raised greatly. A mathematical model between geometrical concentration ratio, reflection times and the corresponding parameters is established, where the corresponding parameters include the parabola coefficient, outermost collector width, collector height, the expanding angle and the collector quantity. Numerical simulation results show that more than 1200x geometrical concentration ratio of the proposed concentrator is achieved without any leakage from the lightguide.

  5. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    Science.gov (United States)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  6. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran (Univ. of Gaevle, Gaevle (Sweden)); Meijer, Jan-Erik; Rosqvist, Haakan (NSR AB, Helsingborg (Sweden))

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  7. Turbo-gas emissions and integrated pollution prevention and control (IPPC)

    International Nuclear Information System (INIS)

    Mariani, M.; Sera, B.

    2005-01-01

    The present paper considers the gas-turbine pollution and joints out that the NO, is the most important pollutant among others pollutants as well as the carbon oxide and the volatile organic compounds because the NO x , has a high mass production rate (in the combustion chamber), elevated toxicity to the ecosystem and because of being in the atmosphere a precursor of secondary ultrafine particles PM 2,5 . In with reference to the integrated pollution and control (IPPC) the job shows schemes of chain chemical reactions which are on the base of the formation of different types of NO x , thermal and organic, and it illustrates the influence of some operative parameters on the combustion's efficiency and then on the NO x , production rate. Also, the study gives the best absolvable techniques (BAT) to reduce the NO x , production rate and to demolish it before its introduction, as well as gas exhaust, in the atmosphere. At the end, the work shows that the gas-turbine are to consider thermal engines with a little environment impact index specially when they make use of the natural gas, as well as fuel [it

  8. Lightweight space radiator with leakage control by internal electrostatic fields

    International Nuclear Information System (INIS)

    Kim, H.; Bankoff, S.G.; Miksis, M.J.

    1991-01-01

    An electrostatic liquid film space radiator is proposed. This will employ an internal electrostatic field to prevent leakage of the liquid-metal coolant out of a puncture. This overcomes the major disadvantage of membrane radiators, which is their vulnerability to micrometeorite impacts. Calculations show that leaks of liquid lithium at 700 degree K can easily be stopped from punctures which are several mm in diameter, with very large safety factors. The basic idea lends itself to a variety of radiator concepts, both rotating and non-rotating. Some typical film thickness and pressure calculations in the presence of an electric field are shown

  9. Regulatory concerns for leakage testing of packagings with three O-ring closure seals

    International Nuclear Information System (INIS)

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-01-01

    The American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) provides guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements and also provides guidance in determining appropriate acceptance criteria. Recent radioactive packagings designs have incorporated three O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results of leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can be caused in two ways, a large leakage in the containment seal or leakage in the inner seal. This paper will describe the problem together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packagings before a particular packaging design can be certified for transport

  10. Research and development of a high-temperature helium-leak detection system (joint research). Part 1 survey on leakage events and current leak detection technology

    Energy Technology Data Exchange (ETDEWEB)

    Sakaba, Nariaki; Nakazawa, Toshio; Kawasaki, Kozo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Urakami, Masao; Saisyu, Sadanori [Japan Atomic Power Co., Tokyo (Japan)

    2003-03-01

    In High Temperature Gas-cooled Reactors (HTGR), the detection of leakage of helium at an early stage is very important for the safety and stability of operations. Since helium is a colourless gas, it is generally difficult to identify the location and the amount of leakage when very little leakage has occurred. The purpose of this R and D is to develop a helium leak detection system for the high temperature environment appropriate to the HTGR. As the first step in the development, this paper describes the result of surveying leakage events at nuclear facilities inside and outside Japan and current gas leakage detection technology to adapt optical-fibre detection technology to HTGRs. (author)

  11. Corrosion Prevention And Control In High Pressure Oil And Gas Transmission Pipelines

    International Nuclear Information System (INIS)

    Hafez, M.T.; Radwan, M.H.; Jones, D.G.

    2004-01-01

    At the start of the 1990s there were concerns over the increasing threat of corrosion to the integrity of high-pressure oil and gas transmission pipelines. For example: corrosion was the major cause of reportable incidents in North America (1]. Corrosion was the major cause of pipeline failure in the Gulf of Mexico [2]. Corrosion in a North American onshore oil pipeline had required over $1 billion in repairs(3]. Internal corrosion along the complete length of pipelines had resulted in replacement[4] . However, the worldwide published failure statistics indicate that the incidents of corrosion are not increasing year on year(5-9]. Indeed, CONCA WE[8,9] statistics (for pipelines In Western Europe) show that the failure rate from corrosion (the most likely failure mode with increasing age) has not increased with pipeline age (Figure 1). In fact the statistics for gas pipelines in Europe

  12. Electron beam treatment technology for exhaust gas for preventing acid rain

    International Nuclear Information System (INIS)

    Aoki, Shinji

    1990-01-01

    Recently, accompanying the increase of the use of fossil fuel, the damage due to acid rain such as withering of trees and extinction of fishes and shells has occurred worldwide, and it has become a serious problem. The sulfur oxides and nitrogen oxides contained in exhaust gas are oxidized by the action of sunbeam to become sulfuric acid and nitric acid mists, which fall in the form of rain. Acid rain is closely related to the use of the coal containing high sulfur, and it hinders the use of coal which is rich energy source. In order to simplify the processing system for boiler exhaust gas and to reduce waste water and wastes, Ebara Corp. developed the dry simultaneous desulfurizing and denitrating technology utilizing electron beam in cooperation with Japan Atomic Energy Research Institute. The flow chart of the system applied to the exhaust gas treatment in a coal-fired thermal power station is shown. The mechanism of desulfurization and denitration, and the features of this system are described. The demonstration plant was constructed in a coal-fired thermal power station in Indianapolis, Indiana, USA, and the trial operation was completed in July, 1987. The test results are reported. (K.I.)

  13. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  14. Prevention

    Science.gov (United States)

    ... Contact Aging & Health A to Z Find a Geriatrics Healthcare Professional Medications & Older Adults Making Your Wishes ... Prevention Hearing Loss Heart Attack High Blood Pressure Nutrition Osteoporosis Shingles Skin Cancer Related News Quitting Smoking, ...

  15. Post Chlorine gas exposure administration of nitrite prevents lung injury: effect of administration modality

    Science.gov (United States)

    Samal, Andrey A.; Honavar, Jaideep; Brandon, Angela; Bradley, Kelley M.; Doran, Stephen; Liu, Yanping; Dunaway, Chad; Steele, Chad; Postlethwait, Edward M.; Squadrito, Giuseppe L.; Fanucchi, Michelle V.; Matalon, Sadis; Patel, Rakesh P.

    2012-01-01

    Cl2 gas toxicity is complex and occurs during, and post exposure leading to acute lung injury (ALI) and reactive airway syndrome (RAS). Moreover, Cl2 exposure can occur in diverse situations encompassing mass casualty scenarios underscoring the need for post-exposure therapies that are efficacious and amenable to rapid and easy administration. In this study, we compared the efficacy of a single dose, post (30min) Cl2 exposure administration of nitrite (1mg/kg) via intraperitoneal (IP) or intramuscular (IM) injection in rats, to decrease ALI. Exposure of rats to Cl2 gas (400ppm, 30min) significantly increased ALI and caused RAS 6–24h post exposure as indexed by BAL sampling of lung surface protein, PMN and increased airway resistance and elastance prior to and post methacholine challenge. IP nitrite decreased Cl2 - dependent increases in BAL protein but not PMN. In contrast IM nitrite decreased BAL PMN levels without decreasing BAL protein in a xanthine oxidoreductase independent manner. Histological evaluation of airways 6h post exposure showed significant bronchial epithelium exfoliation and inflammatory injury in Cl2 exposed rats. Both IP and IM nitrite improved airway histology compared to Cl2 gas alone, but more coverage of the airway by cuboidal or columnar epithelium was observed with IM compared to IP nitrite. Airways were rendered more sensitive to methacholine induced resistance and elastance after Cl2 gas exposure. Interestingly, IM nitrite, but not IP nitrite, significantly decreased airway sensitivity to methacholine challenge. Further evaluation and comparison of IM and IP therapy showed a two-fold increase in circulating nitrite levels with the former, which was associated with reversal of post-Cl2 exposure dependent increases in circulating leukocytes. Halving the IM nitrite dose resulted in no effect in PMN accumulation but significant reduction of of BAL protein levels indicating distinct nitrite dose dependence for inhibition of Cl2 dependent

  16. Administration of nitrite after chlorine gas exposure prevents lung injury: effect of administration modality.

    Science.gov (United States)

    Samal, Andrey A; Honavar, Jaideep; Brandon, Angela; Bradley, Kelley M; Doran, Stephen; Liu, Yanping; Dunaway, Chad; Steele, Chad; Postlethwait, Edward M; Squadrito, Giuseppe L; Fanucchi, Michelle V; Matalon, Sadis; Patel, Rakesh P

    2012-10-01

    Cl(2) gas toxicity is complex and occurs during and after exposure, leading to acute lung injury (ALI) and reactive airway syndrome (RAS). Moreover, Cl(2) exposure can occur in diverse situations encompassing mass casualty scenarios, highlighting the need for postexposure therapies that are efficacious and amenable to rapid and easy administration. In this study, we assessed the efficacy of a single dose of nitrite (1 mg/kg) to decrease ALI when administered to rats via intraperitoneal (ip) or intramuscular (im) injection 30 min after Cl(2) exposure. Exposure of rats to Cl(2) gas (400 ppm, 30 min) significantly increased ALI and caused RAS 6-24h postexposure as indexed by BAL sampling of lung surface protein and polymorphonucleocytes (PMNs) and increased airway resistance and elastance before and after methacholine challenge. Intraperitoneal nitrite decreased Cl(2)-dependent increases in BAL protein but not PMNs. In contrast im nitrite decreased BAL PMN levels without decreasing BAL protein in a xanthine oxidoreductase-dependent manner. Histological evaluation of airways 6h postexposure showed significant bronchial epithelium exfoliation and inflammatory injury in Cl(2)-exposed rats. Both ip and im nitrite improved airway histology compared to Cl(2) gas alone, but more coverage of the airway by cuboidal or columnar epithelium was observed with im compared to ip nitrite. Airways were rendered more sensitive to methacholine-induced resistance and elastance after Cl(2) gas exposure. Interestingly, im nitrite, but not ip nitrite, significantly decreased airway sensitivity to methacholine challenge. Further evaluation and comparison of im and ip therapy showed a twofold increase in circulating nitrite levels with the former, which was associated with reversal of post-Cl(2) exposure-dependent increases in circulating leukocytes. Halving the im nitrite dose resulted in no effect in PMN accumulation but significant reduction of BAL protein levels, indicating a distinct

  17. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  18. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  19. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  20. Study of quantification and distribution of explosive mixture in a confined space as a result of natural gas leak

    Directory of Open Access Journals (Sweden)

    Tulach Aleš

    2014-03-01

    Full Text Available The contribution deals with quantification of natural gas leak from a domestic low pressure pipe to a confined space in relation to formation of explosive concentration. Within the experiments, amount of leak gas was determined considering the character of pipe damage. Leakage coefficients, natural gas expansion and time before reaching the lower explosive limit of a gas-air mixture were taken. Conducted experiments were then modelled using CFD software and the results were verified. In numerical model, several models of flow were used and afterwards following issues were analysed: leakage velocity, spatial distribution of the mixture in a confined space, formation of concentration at the lower explosive limit etc. This work should contribute to better understanding of propagation and distribution of gaseous fuel mixtures in confined spaces and thereby significantly reduce the risk of fires or explosions or prevent them.

  1. Evaluation of marginal leakage of different temporary restorative materials in Endodontics

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Duarte França de Castro

    2013-01-01

    Full Text Available Aim: The aim of this study is to assess the coronal marginal leakage of three temporary restorative materials used for root canal sealing after endodontic treatment. Materials and Methods: A total of 88 single-rooted teeth were submitted to biomechanical preparation and filled by lateral condensation technique. After obturation process, the teeth were randomly separated into four groups, being two teeth of each group used as positive and negative control. Temporary sealing was performed as follows: GI - Clip F (VOCO; GII - Bioplic (Biodinβmica; GIII - Vitremer (3M ESPE and GIV - Ketak N100 (3M ESPE. Next, the specimens were immersed into Indian ink for 30 and 60- days, being 10 specimens for each time interval and then submitted to diaphanization to verify the amount of coronal leakage using a measuring microscope. Results : Leakage mean values within the 30-day period were as follows: Vitremer (0.3 mm, Ketak N100 and Clip F (0.6 mm and Bioplic (1.7 mm. Within the 60-day period, leakage means were 1.1 mm, 1.5 mm, 2.2 mm and 2.6 mm, respectively. Conclusions: None of the materials was capable of preventing marginal leakage within the 30- and 60-day period. In both time intervals, Bioplic presented the highest mean of leakage and Vitremer the lowest.

  2. Ray-leakage-free planar solar concentrator featuring achromatic hybrid collectors and innovative secondary optical elements

    Science.gov (United States)

    Yin, Peng; Xu, Xiping; Jiang, Zhaoguo

    2017-11-01

    For high concentration ratio of the planar concentrator which is mainly used for photovoltaic or solar-thermal applications, the ray-leakage must be prevented during rays propagated in the lightguide. In this paper, the design of a ray-leakage-free planar solar concentrator is introduced with achromatic hybrid collectors and innovative secondary optical elements. The distance between two columns of dimple structures is larger because the collector width is irrelevant to the collector length, which prompts the ray-leakage-free propagating length can be raised greatly. Put differently, the proposed concentrator can obtain a high geometrical concentration ratio while achieving a high optical efficiency. To increase the ray-leakage-free propagating distance, a mathematical model between ray-leakage-free propagating length and the corresponding parameters is established, where the corresponding parameters include the parabola coefficient, the width of collector, the concentrator height and the small expanding angle of the dimple structure. Numerical results display that more than 5000x geometrical concentration ratio of the proposed concentrator is achieved without any leakage from the lightguide.

  3. On leakage and seepage from geological carbon sequestration sites

    Energy Technology Data Exchange (ETDEWEB)

    Oldenburg, C.M.; Unger, A.J.A.; Hepple, R.P.; Jordan, P.D.

    2002-07-18

    Geologic carbon sequestration is one strategy for reducing the rate of increase of global atmospheric carbon dioxide (CO{sub 2} ) concentrations (IEA, 1997; Reichle, 2000). As used here, the term geologic carbon sequestration refers to the direct injection of supercritical CO{sub 2} deep into subsurface target formations. These target formations will typically be either depleted oil and gas reservoirs, or brine-filled permeable formations referred to here as brine formations. Injected CO{sub 2} will tend to be trapped by one or more of the following mechanisms: (1) permeability trapping, for example when buoyant supercritical CO{sub 2} rises until trapped by a confining caprock; (2) solubility trapping, for example when CO{sub 2} dissolves into the aqueous phase in water-saturated formations, or (3) mineralogic trapping, such as occurs when CO{sub 2} reacts to produce stable carbonate minerals. When CO{sub 2} is trapped in the subsurface by any of these mechanisms, it is effectively sequestered away from the atmosphere where it would otherwise act as a greenhouse gas. The purpose of this report is to summarize our work aimed at quantifying potential CO{sub 2} seepage due to leakage from geologic carbon sequestration sites. The approach we take is to present first the relevant properties of CO{sub 2} over the range of conditions from the deep subsurface to the vadose zone (Section 2), and then discuss conceptual models for how leakage might occur (Section 3). The discussion includes consideration of gas reservoir and natural gas storage analogs, along with some simple estimates of seepage based on assumed leakage rates. The conceptual model discussion provides the background for the modeling approach wherein we focus on simulating transport in the vadose zone, the last potential barrier to CO{sub 2} seepage (Section 4). Because of the potentially wide range of possible properties of actual future geologic sequestration sites, we carry out sensitivity analyses by

  4. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    : This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy...... interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6...... instead of clinical leakage. However, anastomotic breaking strength was reduced in the ischemic anastomoses. STUDY 4: In this systematic review MEDLINE, Embase and Cinahl were searched up to September 2011 to identify studies evaluating external coating of colonic anastomoses. Most studies were...

  5. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...... to be used in commercial PV inverters for the measurement of leakage and fault ground currents. The German VDE0126–1–1 standard gives the limit for fault and leakage ground currents and all grid connected PV inverters have to comply with these limits and disconnect from the grid in case of a fault....

  6. Off-gas recirculation system for nuclear reactors

    International Nuclear Information System (INIS)

    Eppler, M.; Lade, H.J.

    1975-01-01

    According to the invention, it is suggested to provide a buffer vessel in the ring main of the off-gas recirculation system for off-gases of a nuclear reactor to which all chambers or vessels which may contain radioactively contaminated gases are connected, within the connection line to outside air. This is to prevent the immediate release of an appreciable amount of gas to the outside air due to pressure variations conditioned by the sequence of operations - e.g. on the filling of the coolant storage. After the improvement, the released gas may be reduced to the amount of gas corresponding to the leakage gas flow entering the ring mains system. (TK) [de

  7. Prevention

    DEFF Research Database (Denmark)

    Halken, S; Høst, A

    2001-01-01

    , breastfeeding should be encouraged for 4-6 months. In high-risk infants a documented extensively hydrolysed formula is recommended if exclusive breastfeeding is not possible for the first 4 months of life. There is no evidence for preventive dietary intervention neither during pregnancy nor lactation...... populations. These theories remain to be documented in proper, controlled and prospective studies. Breastfeeding and the late introduction of solid foods (>4 months) is associated with a reduced risk of food allergy, atopic dermatitis, and recurrent wheezing and asthma in early childhood. In all infants....... Preventive dietary restrictions after the age of 4-6 months are not scientifically documented....

  8. Studies of water leakage in dams. Course

    International Nuclear Information System (INIS)

    Cordero-Calderon, C.F.

    1995-01-01

    With this training about the study of Water Leakage in Dams and Damming, the institutional worker will have the necessary criteria in this topic, and also an opportunity to analyze the impact of this engineering work at national level. This course permits to transmit part of the knowlege acquired by the Arcal XVIII RLA/8/018, Application of Tracer Techniques for Leakage in Dams and Damming Project, where ICE participates in agreement with Atomic Energy Commission of Costa Rica, sponsored by the International Organization of Atomic Energy. (author). 14 charts, 36 figs, 2 maps, 6 tabs

  9. Inward Leakage in Tight-Fitting PAPRs

    Directory of Open Access Journals (Sweden)

    Frank C. Koh

    2011-01-01

    Full Text Available A combination of local flow measurement techniques and fog flow visualization was used to determine the inward leakage for two tight-fitting powered air-purifying respirators (PAPRs, the 3M Breathe-Easy PAPR and the SE 400 breathing demand PAPR. The PAPRs were mounted on a breathing machine head form, and flows were measured from the blower and into the breathing machine. Both respirators leaked a little at the beginning of inhalation, probably through their exhalation valves. In both cases, the leakage was not enough for fog to appear at the mouth of the head form.

  10. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  11. EMISSIONS FROM INDIRECT LAND USE CHANGE: DO THEY MATTER WITH FUEL MARKET LEAKAGES?

    Directory of Open Access Journals (Sweden)

    Dušan Drabik

    2013-09-01

    Full Text Available Indirect land use change, an agricultural market leakage, has been a major controversy over the Environmental Protection Agency’s (EPA requirement for corn-ethanol to reduce greenhouse gas (GHG emissions by 20 percent relative to gasoline it is assumed to replace. This paper shows that corn-ethanol policies generate far greater carbon leakage in the fuel market itself. Hence, corn-ethanol does not meet EPA’s threshold, regardless of ethanol policy and whether one includes emissions from land use change.

  12. Crystallisation of Gypsum and Prevention of Foaming in Wet Flue Gas Desulphurisation (FGD) Plants

    DEFF Research Database (Denmark)

    Hansen, Brian Brun

    faces. Excessive foaming within wet FGD-plants has been associated with a range of operational problems as well as an increased degree of SO2 absorption. Foaming agents include surfactants, macromolecules (such as polymers or proteins), and finely dispersed solids. The foaming ability of particles......, electrolytes and buffers, present in a wet FGD-plant, has been investigated by laboratory scale Bikerman experiments. Adipic acid, as well as a combination of small particles and an electrolyte, have been demonstrated to generate weak transient foams. Pilot plant experiments showed an increased absorption......The aim of this project is to investigate two operational problems, which have been experienced during wet flue gas desulphurisation (FGD) operation, i.e. poor gypsum dewatering properties and foaming. The results of this work can be used for the optimization of wet FGD-plants in terms...

  13. A multicenter study of preventable contact burns from glass fronted gas fireplaces.

    Science.gov (United States)

    Wibbenmeyer, Lucy; Gittelman, Michael A; Kluesner, Karen; Liao, Junlin; Xing, Yunfan; Faraklas, Iris; Anyan, Walter; Gamero, Chelsea; Moulton, Steven; Nederveld, Cindy; Banks, Ashley; Ryan, Colleen M; Conway, Jennifer A; Reilly, Debra A; Fish, Joel; Kelly, Charis; Peltier, George; Schwantke, Emily; Conrad, Peggie F; Caruso, Daniel M; Richey, Karen J; McCrory, Kristine; Elfar, Mohamed S A; Pittinger, Timothy; Sadie, Christine; Greenhalgh, David; Palmieri, Tina; Grossman, Peter H; Richards, Kurt M; Joyce, Teresa; Pozez, Andrea L; Savetamal, Alisa; Harrington, David T; Duncan, Kimberley; Pomerantz, Wendy J; Dillard, B Daniel

    2015-01-01

    Glass fronted gas fireplaces (GFGFs) have exterior surfaces that can reach extremely high temperatures. Burn injuries from contact with the glass front can be severe with long-term sequelae. The Consumer Product Safety Commission reported that these injuries are uncommon, whereas single-center studies indicate a much higher frequency. The purpose of this multi-institutional study was to determine the magnitude and severity of GFGF injuries in North America. Seventeen burn centers elected to participate in this retrospective chart review. Chart review identified 402 children ≤10 years of age who sustained contact burns from contact with GFGF, who were seen or admitted to the study hospitals from January 2006 to December 2010. Demographic, burn, treatment, and financial data were collected. The mean age of the study group was 16.8 ± 13.3 months. The majority suffered burns to their hands (396, 98.5%), with burns to the face being the second, much less common site (14, 3.5%). Two hundred and sixty-nine required rehabilitation therapy (66.9%). The number of GFGF injuries reported was 20 times greater than the approximately 30 injuries estimated by the Consumer Product Safety Commission's 10-year review. For the affected children, these injuries are painful, often costly and occasionally can lead to long-term sequelae. Given that less than a quarter of burn centers contributed data, the injury numbers reported herein support a need for broader safety guidelines for gas fireplaces in order to have a significant impact on future injuries.

  14. [Nursing Experience With a Patient With Gastrostomy Leakage Resulting in Moisture-Associated Skin Damage].

    Science.gov (United States)

    Hsu, Mei-Yu; Hsu, Hsiao-Hui; Lyu, Ji-Yan

    2016-10-01

    Leakage is a common complication of gastrostomy. Exposure of the skin surrounding the gastrostomy tube to moisture or chemical irritants may cause moisture-associated skin damage (MASD) and seriously affect the patient's quality of life. This case study describes a nursing experience with gastrostomy leakage that resulted in MASD. An assessment conducted from July 29, 2015 to August 20, 2015 revealed that heavy gastronomy leakage had caused extensive skin erosion, ulceration, hyperplasia, and superficial infection. Simultaneously, the patient was required to conduct complex stoma care, which resulted in physical and psychological exhaustion. Changes in traditional tube and wound care were discussed on multiple occasions with an interdisciplinary healthcare team. Based on the evidence-based literature, we provide gastrostomy and MASD management strategies. Through team collaboration, we prevented gastric contents from contacting the patient's skin directly, improved patient comfort, controlled effluent and skin infections, maintained fluid and electrolyte balances, and acce-lerated the healing of the damaged skin. We recommend that healthcare professionals caring for patients with gastrostomy leakage be provided with early skin protection programs to learn the standard methods for identifying and correcting leakage factors, containing effluent, and adequately stabilizing the gastrostomy tube in order to reduce the impact on the patient's quality of life. In addition, patient education on tube and skin care should be provided to prevent the reoccurrence of complications.

  15. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attacker...... on the Onion Routing protocol....

  16. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  17. Continuous leakage location in noisy environment using modal and wavelet analysis with one AE sensor.

    Science.gov (United States)

    Mostafapour, Amir; Davoodi, Saman

    2015-09-01

    A noble method for continuous leakage source location with one sensor in gas-filled pipe and noisy environment is proposed based on wavelet analysis and modal location theory. The leakage signals were analyzed into high and low frequencies by wavelet decomposition and noises and reflected waves were omitted. Then the processed signals were reconstructed. A frequency range of 0-250kHz was selected using wavelet packet decomposition to analyze the flexural and extensional modes of leakage signals. In this frequency range, the peak magnitudes of wavelet transform could determine the arrival times of different modes. The frequencies which the peak magnitudes of wavelet transform occurred per them were chosen to calculate the group velocities. Experiments were carried out and the locating results show the high precision of this algorithm. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  19. The impact of transmission constraints on the emissions leakage under cap-and-trade program

    International Nuclear Information System (INIS)

    Sauma, Enzo

    2012-01-01

    Several regional cap-and-trade (C and T) programs are considered or implemented in the United States to control greenhouse gas emissions from the power sector. One concern is the possibility of emissions leakage due to a lack of coherence in the geographic scope of the regional electricity market and the C and T program. Leakage in the context of regulating CO 2 emissions is defined as the short-run displacement of CO 2 emissions from the capped region to other uncapped regions due to the imposition of a regional C and T scheme. However, the presence of transmission congestion could interact with regulations in an unanticipated way to determining whether leakage would occur and its magnitude if happens. In this paper, we use a two-node network to study the conditions under which the CO 2 leakage would happen in a radial network under a C and T program. These conditions are related to transmission capacity, merit order change, and relative production cost between capped and uncapped regions. Since CO 2 leakage would likely occur in a radial network during the time when there is surplus transmission capacity, if regional CO 2 policies could influence power grid management and operations decisions, then there might be space for a better multi-objective coordination. - Highlights: ► We study conditions under which the CO 2 leakage would happen under a C and T program. ► Conditions relate to transmission capacity, merit order change and production cost. ► Transmission congestion interacts with environmental regulations. ► CO 2 leakage would likely occur when there is surplus transmission capacity. ► Power grid management and operations decisions should be carefully scrutinized.

  20. Improving Reliability of Information Leakage Detection and Prevention Systems

    Directory of Open Access Journals (Sweden)

    A. V. Mamaev

    2011-03-01

    Full Text Available The problem of protection from deliberate leaks of information is one of the most difficult. Integrated systems of information protection against insider have a serious drawback. Using this disadvantage the offender receives the possibility of unauthorized theft of information from working machine.

  1. Colorectal Anastomoses : Surgical outcome and prevention of anastomotic leakage

    NARCIS (Netherlands)

    Bakker, Ilsalien

    2016-01-01

    Colorectal surgery is a frequently performed procedure with more than 10.000 annual resections in the Netherlands. The majority of resections are performed for colorectal cancer. The first part of this thesis focused on outcome of colorectal cancer surgery in the Netherlands based on the nationwide

  2. Response to Comment by Rabilloud on 'prevented Mortality and Greenhouse Gas Emissions from Historical and Projected Nuclear Power'

    Science.gov (United States)

    Kharecha, Pushker A.; Hansen, James

    2013-01-01

    The critique by Rabilloud-whose only listed professional affiliation is an antinuclear activist group?is grossly biased and contains numerous misleading, hyperbolic, and erroneous claims about our paper2 and about nuclear energy in general. The nature of his comments bears a striking resemblance to the fallacious reasoning commonly employed by climate change deniers to try to undermine public concern about the climate crisis. Specifically, he resorts to cherry-picking of information and diversionary (red herring) arguments, demands unrealistic exactness, and cites untrustworthy sources. None of his claims undermine any of the key results of our paper, most notably our conclusion that nuclear energy has prevented, and can continue to prevent, a very high number of fatalities and very large greenhouse gas emissions due to fossil fuel burning. It follows that, as uncomfortable as it is for many well-intentioned environmentalists to admit, efforts to undermine nuclear energy also undermine mitigation of climate change and air pollution, with a heavy cost in human lives and potentially disastrous future climate change.

  3. Leakage monitoring. Acoustic leakage monitoring by means of neural networks in complex pressurized plants

    International Nuclear Information System (INIS)

    Hessel, G.; Schmitt, W.; Vorst, K. van der; Weiss, F.P.

    1996-01-01

    A leakage detection and leakage rate assessment method developed for pressurized plants characterized by a complex three-dimensional topology is introduced. It is based on the features of leak-induced structure-borne or air-borne noise and uses neural networks for pattern recognition. The sound patterns required for neural network instruction can be generated by simulating leaks in the original structure. The method described can also be applied when leakage detection based on skews or damping differences fails. A prototype was developed and tested for a WWER-type reactor. Coherence values of highfrequency microphone signals or the effective values of sound emission sensor signals were used as features for characterization of the leak. The leakage rate assessment features were derived from these effective values. Neural networks allow one to easily adapt the method to pressurized plants of different topologies. (orig.) [de

  4. Influence of the internal anatomy on the leakage of root canals filled with thermoplastic technique.

    Science.gov (United States)

    Al-Jadaa, Anas; Attin, T; Peltomäki, T; Heumann, C; Schmidlin, P R; Paquè, F

    2017-10-11

    The aim of this paper is to evaluate the influence of the internal anatomy on the leakage of root canals filled with the thermoplastic technique. The upper central incisors (UCI) and mesial roots of the lower molars (MRLM) (n = 12 each) were tested regarding leakage using the gas-enhanced permeation test (GEPT) after root filling. The quality of the root fillings was assessed using micro-computed tomography (μCT) by superimposing scans before and after treatment to calculate unfilled volume. The calculated void volume was compared between the groups and correlated to the measured leakage values. Data were analyzed using t test and Pearson's correlation tests (p UCI and MRLM (13.7 ± 6.2% vs. 14.2 ± 6.8%, respectively). However, significantly more leakage was evident in the MRLM (p UCI (R 2  = 0.467, p = 0.126). MRLM showed higher leakage values, which correlated to the void volume in the root canal fillings. Care should always be taken while doing root canal treatments, but attention to teeth with known/expected complex root canal anatomy should be considered.

  5. Current situation and control measures of groundwater pollution in gas station

    Science.gov (United States)

    Wu, Qiong; Zhang, Xiaofeng; Zhang, Qianjin

    2017-11-01

    In recent years, pollution accidents caused by gas station leakage has occurred worldwide which can be persistent in groundwater. Numerous studies have demonstrated that the contaminated groundwater is threatening the ecological environment and human health. In this article, current status and sources of groundwater pollution by gas station are analyzed, and experience of how to prevent groundwater pollution from gas stations are summarized. It is demonstrated that installation of secondary containment measures for the oil storage of the oil tank system, such as installation of double-layer oil tanks or construction of impermeable ponds, is a preferable method to prevent gas stations from groundwater pollution. Regarding to the problems of groundwater pollution caused by gas station, it is proposed that it is urgent to investigate the leakage status of gas station. Relevant precise implementation regulations shall be issued and carried out, and supervision management of gas stations would need to be strengthened. Then single-layer steel oil tanks shall be replaced by double-layer tanks, and the impermeable ponds should be constructed according to the risk ranking. From the control methodology, the groundwater environment monitoring systems, supervision level, laws and regulations as well as pollution remediation should also be carried out and strengthened.

  6. Consequence modeling of fire on Methane storage tanks in a gas refinery

    Directory of Open Access Journals (Sweden)

    Sara Shahedi ali abadi

    2016-06-01

    Full Text Available Introduction: using fossil fuels, some hazards such as explosion and fire are probable. This study was aimed to consequence modeling of fire on Methane storage tanks in a gas refinery using analyzing the risk, and modeling and evaluating the related consequences. Method: Hazard analysis by PHA was used to choosing the worst-case scenario. Then, causes of the scenario were determined by FTA. After that, consequence modeling by the PHAST software was applied for the consequence analysis. Results: Based on some criteria, the fire of methane gas tank (V-100 was selected as the worst-case scenario at the refinery. The qualitative fault tree showed three factors including mechanical, process, and human failures contribute in gas leakage. The leakage size and weather conditions were effective on the distance of radiation. Using consequence modeling, thermal radiation was considered as the major outcome of the incident. Finally, for outcome evaluating, probit equations were used to quantify losses and the percentage of fatalities due to the methane gas leakage and fire occurrence. The maximum number of fatalities caused by fire was obtained 23 persons. Conclusions: In conclusion, the methane gas vessel in the refinery can be considered as the main center of hazard, therefore the implementation of the safety rules, eliminating mechanical failures, personal protection and education, and Effective measures to prevent and fighting of fire are proposed for decreasing the probable losses and fatalities.

  7. An Experimental Study of Emission and Combustion Characteristics of Marine Diesel Engine in Case of Cylinder Valves Leakage

    Directory of Open Access Journals (Sweden)

    Kowalski Jerzy

    2015-09-01

    Full Text Available Presented paper shows the results of the laboratory tests on the relationship between throttling of both air intake duct and exhaust gas duct and a gaseous emission from the marine engine. The object of research is a laboratory, four-stroke, DI diesel engine, operated at loads from 50 kW to 250 kW at a constant speed equal to 750 rpm. During the laboratory tests over 50 parameters of the engine were measured with its technical condition recognized as a „working properly” and with simulated leakage of both air intake valve and exhaust gas valve on the second cylinder. The results of this laboratory research confirm that the leakage of cylinder valves causes no significant changes of the thermodynamic parameters of the engine. Simulated leakages through the inlet and exhaust valve caused a significant increase in fuel consumption of the engine. Valve leakages cause an increase of the exhaust gas temperature behind the cylinder with leakage and behind other cylinders. The exhaust gas temperature increase is relatively small and clearly visible only at low loads of the engine. The increase of the temperature and pressure of the charging air behind the intercooler were observed too. Charging air temperature is significantly higher during the engine operation with inlet valve leakage. The study results show significant increases of the CO, NOx and CO2 emission for all the mentioned malfunctions. The conclusion is that the results of measurements of the composition of the exhaust gas may contain valuable diagnostic information about the technical condition of the air intake duct and the exhaust gas duct of the marine engine.

  8. Occupational exposure prevention program to oil and gas industry; Antecipacao, reconhecimento, avaliacao e controle dos riscos ambientais em uma planta de petroleo e gas

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Paulo Sergio de [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil); Palierini, Renato Martins [TWA Brasil, Sao Caetano do Sul, SP (Brazil)

    2005-07-01

    PETROBRAS/TRANSPETRO Pipelines and Terminals have 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work under 125 contracts involving a wide range of activities such as maintenance, pipeline operation, pipeline launching, engineering, administrative and auxiliary services. Among these workers, 1.200 peoples are subjected to occupational exposure, which may be present in the industrial process or in the products transported in our pipelines, e.g. industrial noise, sulfidric gas, toluene, xylene and benzene (recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour). Our PPRA (acronym in Portuguese for Occupational Exposure Prevention Program) involves the workforce and fosters health by anticipation, recognition, evaluation and control of the situations that may result in injuries. Further actions include the procurement of equipment for detection of these agents not only in the air but also diluted in liquids and the introduction of state-of the- art technologies for a better process control. The priority is the acquisition of equipment for collective protection not forgetting the individual protection equipment (IPE) and the required training. Implementation of this program counted on the effective involvement of the managers, contract supervisors and HSE professionals whose main task was to advise all involved parts on the use the Risk Analysis Methods tailored for Occupational Hygiene. Furthermore, these information will be used in a info system called SD-2000 that will gather and compare Health, Hygiene e Human Resources data in order to support the professional in the management and decision making process. (author)

  9. Carbon Leakage, Free Allocation and Linking Emissions Trading Schemes

    NARCIS (Netherlands)

    Tiche, Fitsum G.; Weishaar, Stefan E.; Couwenberg, Oscar

    2014-01-01

    A sub-global emissions trading scheme (ETS) risks harming competitiveness and causing carbon leakage. These concerns cast doubt on the efficiency and environmental effectiveness of unilateral climate policies. ETSs implemented thus far include measures to address competitiveness and leakage

  10. Accurate characterization of organic thin film transistors in the presence of gate leakage current

    Directory of Open Access Journals (Sweden)

    Vinay K. Singh

    2011-12-01

    Full Text Available The presence of gate leakage through polymer dielectric in organic thin film transistors (OTFT prevents accurate estimation of transistor characteristics especially in subthreshold regime. To mitigate the impact of gate leakage on transfer characteristics and allow accurate estimation of mobility, subthreshold slope and on/off current ratio, a measurement technique involving simultaneous sweep of both gate and drain voltages is proposed. Two dimensional numerical device simulation is used to illustrate the validity of the proposed technique. Experimental results obtained with Pentacene/PMMA OTFT with significant gate leakage show a low on/off current ratio of ∼ 102 and subthreshold is 10 V/decade obtained using conventional measurement technique. The proposed technique reveals that channel on/off current ratio is more than two orders of magnitude higher at ∼104 and subthreshold slope is 4.5 V/decade.

  11. Leakage and Seepage of CO2 from Geologic Carbon Sequestration Sites: CO2 Migration into Surface Water

    International Nuclear Information System (INIS)

    Oldenburg, Curt M.; Lewicki, Jennifer L.

    2005-01-01

    ebullition and bubble flow will be the dominant form of gas transport in surface water for all but the smallest seepage fluxes or shallowest water bodies. The solubility of the gas species in water plays a fundamental role in whether ebullition occurs. We used a solubility model to examine CO 2 solubility in waters with varying salinity as a function of depth below a 200 m-deep surface water body. In this system, liquid CO 2 is stable between the deep regions where supercritical CO 2 is stable and the shallow regions where gaseous CO 2 is stable. The transition from liquid to gaseous CO 2 is associated with a large change in density, with corresponding large change in bubble buoyancy. The solubility of CO 2 is lower in high-salinity waters such as might be encountered in the deep subsurface. Therefore, as CO 2 migrates upward through the deep subsurface, it will likely encounter less saline water with increasing capacity to dissolve CO 2 potentially preventing ebullition, depending on the CO 2 leakage flux. However, as CO 2 continues to move upward through shallower depths, CO 2 solubility in water decreases strongly leading to greater likelihood of ebullition and bubble flow in surface water. In the case of deep density-stratified lakes in which ebullition is suppressed, enhanced mixing and man-made degassing schemes can alleviate the buildup of CO 2 and related risk of dangerous rapid discharges. Future research efforts are needed to increase understanding of CO 2 leakage and seepage in surface water and saturated porous media. For example, we recommend experiments and field tests of CO 2 migration in saturated systems to formulate bubble-driven water-displacement models and relative permeability functions that can be used in simulation models

  12. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  13. Clinical Practice Guidelines for Prevention, Diagnosis and Management of Early and Delayed-onset Ocular Injuries Due to Mustard Gas Exposure.

    Science.gov (United States)

    Rajavi, Zhale; Safi, Sare; Javadi, Mohammad Ali; Jafarinasab, Mohammad Reza; Feizi, Sepehr; Moghadam, Mohammadreza Sedighi; Jadidi, Khosrow; Babaei, Mahmoud; Shirvani, Armin; Baradaran-Rafii, Alireza; Mohammad-Rabei, Hossein; Ziaei, Hossein; Ghassemi-Broumand, Mohammad; Baher, Siamak Delfaza; Naderi, Mostafa; Panahi-Bazaz, Mahmoodreza; Zarei-Ghanavati, Siamak; Hanjani, Shahriar; Ghasemi, Hassan; Salouti, Ramin; Pakbin, Mojgan; Kheiri, Bahareh

    2017-01-01

    To develop clinical practice guidelines (CPGs) for prevention, diagnosis, treatment and follow-up of ocular injuries caused by exposure to mustard gas. The clinical questions were designed by the guideline team. Websites and databases including National Guidelines Clearinghouse, National Institute for Clinical Excellence, Cochrane, and PubMed were searched to find related CPGs and explore possible answers to the clinical questions. Since there were no relevant CPGs in the literature, related articles in Persian and English languages were extracted. Each article along with its level of evidence was summarized. Additionally, hand search was performed by looking the reference list of each article. Consequently, recommendations were developed considering the clinical benefits and side effects of each therapeutic modality. The recommendations were re-evaluated in terms of customization criteria. All recommendations along with the related evidence were scored from 1 to 9 by experts from all medical universities of Iran. The level of agreement among the experts was evaluated by analyzing the given scores. The agreement was achieved for all recommendations. The experts suggested a number of minor modifications which were applied to the recommendations. Finally, CPGs were developed with 98 recommendations under three major domains including prevention of injury, diagnosis and management of the acute and delayed-onset mustard gas ocular injuries. Considering the lack of CPGs for the prevention, diagnosis, and management of mustard gas-induced keratitis, these recommendations would be useful to prevent the serious ocular complications of mustard gas and standardize eye care services to the affected individuals.

  14. Improvement in oil seal performance of gas compressor in HTTR

    International Nuclear Information System (INIS)

    Oyama, Sunao; Hamamoto, Shimpei; Nemoto, Takahiro; Sekita, Kenji; Isozaki, Minoru; Emori, Kouichi; Ohta, Yukimaru; Mizushima, Toshihiko; Kaneshiro, Noriyuki; Ito, Yoshiteru; Yamamoto, Hideo

    2007-08-01

    High-Temperature engineering Test Reactor (HTTR) built by Japan Atomic Energy Agency (JAEA) has reciprocating compressor commonly used to extract and discharge helium gas into primary/secondary coolant helium loop from helium purification system. Piston rod seal of the compressor consist of several components to prevent coolant leak. However, rod seal system has weak reliability during long term operation due to repeated leakage of seal oil in operation. As a result of investigations, leakage's root is found in that seal were used in a range beyond limit sliding properties of seal material. For this reason, a lip of the seal was worn and transformed itself and was not able to sustain a seal function. Therefore, through tests using facility actual equipment for endurance of candidate materials, one seal material were chosen for long term operation. (author)

  15. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  16. Alopecia associated with unexpected leakage from electron cone

    International Nuclear Information System (INIS)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-01-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region

  17. Use of oxygen dosing to prevent flow accelerated corrosion in British Energy's Advanced Gas-Cooled Reactors

    International Nuclear Information System (INIS)

    Quirk, G.P.; Woolsey, I.S.; Rudge, A.

    2010-01-01

    Flow accelerated corrosion (FAC) was recognized as major threat to the carbon steel feed and economizer tubing of the once-through boilers of the UK's Advanced Gas-cooled Reactors (AGRs) following the observation of FAC damage of the boiler inlet orifice assemblies at two plants in 1977, and subsequent review of the likelihood of further damage elsewhere within the boilers of all AGRs. In most cases, replacement of susceptible tubing was not feasible; due to the inaccessibility of the boiler components within the reactor concrete pressure vessel. Preventing further FAC damage within the boilers therefore had to rely largely on changes to the boiler feedwater chemistry. Following extensive research programs carried out in the late 1970s and early 1980s two main feedwater chemistry regimes were adopted to suppress FAC in different AGRs. The four units found to be at greatest risk of FAC damage adopted an oxygen dosed All Volatile Treatment (AVT) regime during commissioning, while four other units retained the original deoxygenated ammonia dosed AVT regime, but with an increased feedwater pH. The deoxygenated ammonia dosed chemistry regime was also adopted in four AGR units subsequently built, which used 1%Cr0.5%Mo feed and economizer tubing in their once-through boilers. The oxygen dosed AVT chemistry regime adopted in four units having helical once-through boilers has proved highly effective in preventing FAC, with no evidence of damage after around 150,000 hours of operation. However, FAC damage was eventually found in some of the other units operating with a deoxygenated feedwater chemistry regime, in spite of having adopted an elevated feedwater pH. These units have now successfully converted to an oxygen dosed AVT feedwater chemistry regime to prevent further FAC damage, with the result that all 14 AGR reactors now operate with variants of the original oxygen dosed feedwater chemistry regime developed during the 1980s. The paper outlines the development of

  18. Control room habitability assessment and in-leakage test for Korean NPP - 15510

    International Nuclear Information System (INIS)

    Song, D.S.; Lee, J.B.; Ha, S.J.; Seong, J.J.

    2015-01-01

    The assessment of control room habitability for Wolsung unit 1 was performed based on GL 2003-01 and Reg. Guide 1.197. The control room habitability program including Control Room Envelope (CRE) in-leakage test procedures, self assessment guidance, CRE boundary control program, CRE maintenance/sealing program was developed for Wolsung unit 1. The integrated CRE test was performed utilizing ASTM E741. There are two operating modes of pressurization and isolation for CRE ventilation test, and four tests were performed using each of the control room HVAC sub-trains. The control room HVAC system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The in-leakage testing was performed in accordance with CRE in-leakage test procedures. In the pressurization mode, measured unfiltered in-leakage rates for train A and train B were 0 CFM and 405 CFM respectively. In the isolation mode, measured unfiltered in-leakage rates for train A and train B were 1,739 CFM and 1,502 CFM, respectively. Maximum concentration of ammonia at the control room HVAC intake is calculated to be 0.027 g/m 3 (39 ppm), and satisfied the toxicity limit of 300 ppm. The test result shows that the measured unfiltered in-leakage is bounded by the regulatory criteria assumed in the design basis radiological analyses. (authors)

  19. Bacterial leakage through temporary fillings in core buildup composite material - an in vitro study.

    Science.gov (United States)

    Rechenberg, Dan-Krister; Schriber, Martina; Attin, Thomas

    2012-08-01

    To evaluate the ability of the provisional filling material Cavit-W alone or in combination with different restorative materials to prevent bacterial leakage through simulated access cavities in a resin buildup material. LuxaCore resin cylinders were subdivided into 4 experimental groups (n = 30), plus a positive (n = 5) and a negative (n = 30) control group. One bore hole was drilled through each cylinder, except those in the negative control group (G1). The holes were filled with Cavit-W (G2), Cavit-W and Ketac-Molar (glassionomer cement, G3), Cavit-W and LuxaCore bonded with LuxaBond (G4), Cavit-W and LuxaCore (G5), or left empty (G6). Specimens were mounted in a two-chamber leakage setup. The upper chamber was inoculated with E. faecalis. An enterococci-selective broth was used in the lower chamber. Leakage was assessed for 60 days and compared using Fisher's exact test (α Cavit-W alone or combined with a glass-ionomer cement did not prevent bacterial leakage through a resin buildup material for two months. In contrast, covering Cavit-W with a bonded resin material resulted in a bacteria-tight seal for two months.

  20. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  1. Analytical methods of leakage rate estimation from a containment under a LOCA

    International Nuclear Information System (INIS)

    Chun, M.H.

    1981-01-01

    Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from then mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than the mass leakage rate formula of CONTEMPT-LT. (author)

  2. Indian Ocean sources of Agulhas leakage

    Science.gov (United States)

    Durgadoo, Jonathan V.; Rühs, Siren; Biastoch, Arne; Böning, Claus W. B.

    2017-04-01

    We examine the mean pathways, transit timescales, and transformation of waters flowing from the Pacific and the marginal seas through the Indian Ocean (IO) on their way toward the South Atlantic within a high-resolution ocean/sea-ice model. The model fields are analyzed from a Lagrangian perspective where water volumes are tracked as they enter the IO. The IO contributes 12.6 Sv to Agulhas leakage, which within the model is 14.1 ± 2.2 Sv, the rest originates from the South Atlantic. The Indonesian Through-flow constitutes about half of the IO contribution, is surface bound, cools and salinificates as it leaves the basin within 10-30 years. Waters entering the IO south of Australia are at intermediate depths and maintain their temperature-salinity properties as they exit the basin within 15-35 years. Of these waters, the contribution from Tasman leakage is 1.4 Sv. The rest stem from recirculation from the frontal regions of the Southern Ocean. The marginal seas export 1.0 Sv into the Atlantic within 15-40 years, and the waters cool and freshen on-route. However, the model's simulation of waters from the Gulfs of Aden and Oman are too light and hence overly influenced by upper ocean circulations. In the Cape Basin, Agulhas leakage is well mixed. On-route, temperature-salinity transformations occur predominantly in the Arabian Sea and within the greater Agulhas Current region. Overall, the IO exports at least 7.9 Sv from the Pacific to the Atlantic, thereby quantifying the strength of the upper cell of the global conveyor belt.

  3. Improvement of leakage current characteristics of Ba0.5Sr0.5TiO3 films by N2O plasma surface treatment

    Science.gov (United States)

    Cho, Hag-Ju; Oh, Sejun; Kang, Chang Seok; Hwang, Cheol Seong; Lee, Byoung Taek; Lee, Ki Hoon; Horii, Hideki; Lee, Sang In; Lee, Moon Yong

    1997-12-01

    The effects of plasma surface treatment, using N2O gas, of Ba0.5Sr0.5TiO3 (BST) film on the leakage current characteristic of a Pt/BST/Pt capacitor were investigated. As a result of exposure of BST film to the plasma, the leakage current density of the BST capacitor decreased by two orders of magnitude in the high voltage region, and higher onset voltage of an abrupt increase in leakage current was observed. The improvement of leakage properties of BST films can be attributed to the elimination of the bulged curve in the leakage current characteristics. Thermal desorption spectroscopy showed that the elimination was closely related to the reduction of carbon content in the BST film.

  4. Primary containment intergrated leakage rate testing

    International Nuclear Information System (INIS)

    1977-04-01

    Primary containment integrated leakage rate tests (ILRTs) have previously been conducted with a minimum duration of 24 hr. However, analysis of data from recent ILRTs has shown that a test duration considerably less than 24 hr would have been sufficient. This report summarizes these recent ILRTs and analyzes and discusses the test results. Test and analytical methods, including the LEAKFIT computer program, are also discussed. The conclusion is reached that an ILRT with a duration of 6 hr and at least 20 data points is sufficient

  5. Lyman Continuum Leakage in the Local Universe

    Science.gov (United States)

    Leitherer, Claus; Hernandez, Svea; Lee, Janice; Oey, Sally

    2015-08-01

    Star-forming galaxies are viable candidates for providing the ionizing photon supply accounting for the reionization of the early universe. However, direct determination of the fraction of ionizing photons that can escape the optically thick galaxy ISM is challenging. I will discuss Lyman continuum observations of a sample of massive young star clusters in local galaxies which take advantage of a new capability of HST's Cosmic Origins Spectrograph. The derived photon leakages are compared to values found at high redshift and discussed in the context of cosmological models.

  6. EVA Suit Microbial Leakage Investigation Project

    Science.gov (United States)

    Falker, Jay; Baker, Christopher; Clayton, Ronald; Rucker, Michelle

    2016-01-01

    The objective of this project is to collect microbial samples from various EVA suits to determine how much microbial contamination is typically released during simulated planetary exploration activities. Data will be released to the planetary protection and science communities, and advanced EVA system designers. In the best case scenario, we will discover that very little microbial contamination leaks from our current or prototype suit designs, in the worst case scenario, we will identify leak paths, learn more about what affects leakage--and we'll have a new, flight-certified swab tool for our EVA toolbox.

  7. Control of Leakage in the Triaxial Test

    Science.gov (United States)

    1964-03-01

    greased and tightly compressed by the bonnet nut (see Fig. H-10). The rates of leakage of all valves that are sealed by O-Rings are compared in Table 8-5...34 H-10 6 3 Klinger(packing boiled in distilled water and greased and bonnet nut screwed down as far as It would go) 0.20 45 123 2.0 0.05 11...measured a total flow of only 20 mm3 in 10 days through either a silicone-oil-soaked or an unsoaked mem- brane of the type he used. This is about the

  8. Novel sensing approach for LPG leakage detection: Part I: Operating Mechanism and Preliminary Results

    KAUST Repository

    Mukhopadhyay, Subhas

    2015-10-30

    Gas sensing technology has been among the topical research work for quite some time. This paper showcases the research done on the detection mechanism of leakage of domestic cooking gas at ambient conditions. MEMS-based interdigital sensors were fabricated on oxidized single crystal silicon surfaces by maskless photolithography technique. The electrochemical impedance analysis of these sensors was done to detect liquefied petroleum gas (LPG) with and without coated particles of tin oxide (SnO2) in form of thin layer.A thin-film of SnO2 was spin-coated on the sensing surface of the interdigital sensor to induce selectivity to LPG that consists of a 60/40 mixture of propane and butane respectively. The paper reports a novel strategy for gas detection under ambient temperature and humidity conditions. The response time of the coated sensor was encouraging and own a promising potential to the development of a complete efficient gas sensing system.

  9. A Framework to Estimate CO2 Leakage associated with Geological Storage in Mature Sedimentary Basins

    Science.gov (United States)

    Celia, M. A.; Bachu, S.; Gasda, S.

    2002-12-01

    Geological storage of carbon dioxide requires careful risk analysis to avoid unintended consequences associated with the subsurface injection. Most negative consequences of subsurface injection are associated with leakage of the injected CO2 out of the geological formation into which it is injected. Such leakage may occur through natural geological features, including fractures and faults, or it may occur through human-created pathways such as existing wells. Possible leakage of CO2 through existing wells appears to be especially important in mature sedimentary basins that have been explored intensively and exploited for hydrocarbon production. In the Alberta Basin of western Canada, more than 300,000 oil and gas wells have been drilled, while in the state of Texas in the United States, more than 1,500,000 wells have been drilled. Many of these wells have been abandoned, and the information available to describe their current state is highly variable and sometimes nonexistent. Because these wells represent possible direct conduits from the injection zone to the land surface, a comprehensive assessment of leakage potential associated with these wells needs to be pursued. Analysis of leakage potential associated with existing wells must combine a data mining component with a multi-level modeling effort to assess leakage potential in a probabilistic framework. Information available for existing wells must be categorized and analyzed, and general leakage characteristics associated with wells of varying properties must be quantified. One example of a realistic target formation is the Viking Formation in Alberta, which is overlain by a thick shale layer and contains hydrocarbon in some locations. The existence of hydrocarbon in the formation indicates that the overlying shale layer is an effective barrier to flow, and therefore this is a good candidate formation for CO2 storage. However, the formation and its cap rock are punctured by approximately 180,000 wells, with

  10. Knowledge, attitudes, and practices toward malaria risk and prevention among frequent business travelers of a major oil and gas company.

    Science.gov (United States)

    Berg, Johannes; Breederveld, Daan; Roukens, Anna H; Hennink, Yvonne; Schouten, Marjolijn; Wendt, Judy K; Visser, Leo G

    2011-01-01

    Despite significant morbidity and mortality among business travelers due to malaria, very little has been published on knowledge, attitudes, and practices (KAP) toward malaria risk. The aim of this study was to assess KAP among frequent international business travelers (FBT) and to identify recommendations for improving malaria prevention that could be applied to the wider FBT community in occupational health. A retrospective web-based survey was conducted in 2005 among self-registered FBT of an oil and gas company based in the Netherlands. The survey was completed by 328 of the 608 self-registered FBT (54%). Fifty-four percent of respondents had visited a high-risk area for malaria. Most respondents (96%) were experienced travelers; the majority (71%) sought health advice before their trip and made use of a company health resource. Fever was recognized as a malaria symptom by all FBT; travel to high-risk malaria areas was correctly identified by 96%, and 99% of these travelers adhered to use of adequate personal protective measures. The proportion of travelers carrying appropriate anti-malaria drug regimen was positively associated with receiving company advice among FBT traveling to high-risk destinations (RR = 2.10, 95% CI: 1.21-3.67), but not for those traveling to low- or no-risk destinations. Only 8% (14) of those going to a high-risk area were not carrying malaria prophylaxis. One in five of FBT traveling to no-risk areas were unnecessarily carrying malaria prophylaxis. The majority of KAP results were excellent. We postulate that a company culture with a strong focus on health, safety, security, and environment can positively contribute to high KAP scores. Notwithstanding the excellent findings, this study also provides a cautionary tale for company health functions against overprescribing of malaria prophylaxis. It demonstrates the need for constant review and audit of adherence to quality criteria. © 2011 International Society of Travel Medicine.

  11. Will implementation of green gas into the gas supply be feasible in the future?

    International Nuclear Information System (INIS)

    Bekkering, J.; Hengeveld, E.J.; Gemert, W.J.T. van; Broekhuis, A.A.

    2015-01-01

    Highlights: • The relation between energy efficiency, greenhouse gas reduction and cost price of a green gas supply chain was analyzed. • Opportunities for improving a green gas supply chain were evaluated. • Fossil and renewable energy resources are made explicit in energy efficiency definition. • Switching to green electricity is the major contributor to improving the energy efficiency and greenhouse gas reduction. - Abstract: The energy efficiency, greenhouse gas reduction and cost price of a green gas supply chain were evaluated. The considered supply chain is based on co-digestion of dairy cattle manure and maize, biogas upgrading and injection into a distribution gas grid. A reference scenario was defined which reflects the current state of practice, assuming that input energy is from fossil origin. Possible improvements of this reference scenario were investigated. For this analysis two new definitions for energy input–output ratio were introduced; one based on input of primary energy from all origin, and one related to energy from fossil origin only. The influence of the improvements on greenhouse gas reduction and cost price was assessed too. Results show that electricity (from fossil origin) is the major contributor to energy input in the reference scenario. Switching to green electricity significantly improves the energy efficiency (both definitions) and greenhouse gas reduction. Preventing methane leakage during digestion and upgrading, and re-using heat within the supply chain also show improvements on these parameters as well as on cost price, although their influence is smaller. Decreasing the share of energy crops in the substrate mix shows a negative effect. It is shown that greenhouse gas reduction of more than 80% is possible with current technology. To meet this high sustainability level, multiple improvement options will have to be implemented in the green gas supply chain. Doing so will result in a modest decrease of the green gas

  12. Review on water leakage control in distribution networks and the associated environmental benefits.

    Science.gov (United States)

    Xu, Qiang; Liu, Ruiping; Chen, Qiuwen; Li, Ruonan

    2014-05-01

    Water supply is the primary element of an urban system. Due to rapid urbanization and water scarcity, maintaining a stable and safe water supply has become a challenge to many cities, whereas a large amount of water is lost from the pipes of distribution systems. Water leakage is not only a waste of water resources, but also incurs great socio-economic costs. This article presents a comprehensive review on the potential water leakage control approaches and specifically discusses the benefits of each to environmental conservation. It is concluded that water leakage could be further reduced by improving leakage detection capability through a combination of predictive modeling and monitoring instruments, optimizing pipe maintenance strategy, and developing an instant pressure regulation system. The environment could benefit from these actions because of water savings and the reduction of energy consumption as well as greenhouse gas emissions. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  13. Modeling of leakage currents in high-k dielectrics

    International Nuclear Information System (INIS)

    Jegert, Gunther Christian

    2012-01-01

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO 2 material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO 2 /TiN capacitor structures were suggested and problem areas that may

  14. Modeling of leakage currents in high-k dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Jegert, Gunther Christian

    2012-03-15

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO{sub 2} material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO{sub 2}/TiN capacitor structures were suggested and problem areas

  15. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; The oretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  16. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  17. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  18. Effect of Preventive Maintenance on Performance of Air Heater in a Power Plant

    International Nuclear Information System (INIS)

    Jang, Jin Hyung; Hong, Eun Kee; Hwang, Kwang Won; Yun, Rin

    2010-01-01

    Air heater used in power plant helps increase the thermal efficiency of the boiler by recovering the heat from the boiler flue gas and thus preventing the loss of useful heat. This study investigates the effect of preventive maintenance on the performance of the air heater in a power plant. Performance indexes for the air heater are calculated to observe the changes in the performance and operation status of the air heater before and after preventive maintenance. The major performance indexes considered are temperature efficiency of the flue gas side, air leakage rate, heat recovery rate, heat transmission rate, and heat capacity ratio. The performance of the air heater is evaluated before and after preventive maintenance; our results show that all the above mentioned performance indexes are improved after the maintenance

  19. Impaired collagen synthesis in the rectum may be a molecular target in anastomotic leakage prophylaxis

    DEFF Research Database (Denmark)

    Buch, Anastasia S; Schjerling, Peter; Kjaer, Marie

    2017-01-01

    The underlying molecular mechanisms for anastomotic leakage (AL) after colorectal surgery are unknown and there are no therapeutics for AL prevention. Our aim was to correlate endogenous matrix metalloproteinase (MMP) activity, collagen concentration, and collagen/MMP/cytokine mRNA levels with an...... anatomic locations. By elucidating the factors responsible for the decreased collagen production we may identify specific molecular targets in AL prophylaxis....

  20. Analysis of the Relationship between Hamming Distance and the Electromagnetic Information Leakage

    OpenAIRE

    Sun Haimeng; Liu Jinming; Zhang Jiemin; Mao Jian

    2013-01-01

    Electromagnetic information leak as a potential data security risk is more and more serious. Discussing the relationship between compromising emanations and Hamming distance is directed to preventing or reducing the electromagnetic information leakage. The paper presents the model of electromagnetic information leak, then the hierarchical protection strategy based on the model is proposed, that is anti-radiation, anti-intercept and anti-reconstruction. Analyzing the causes of electromagnetic ...

  1. A Model for Determining Leakage in Water Distribution Systems

    OpenAIRE

    Stathis, Jonathan Alexander

    1998-01-01

    Leaks in pipe networks cause significant problems for utilities and water users in terms of lost revenue and interrupted service. In many cities the leakage is as high as forty percent. A water audit is carried out to assess system-wide leakage. However, to detect leakage at the level of a pipeline, a physical measurement technique is generally employed. For large cities the distribution piping length amounts to a few thousand miles. Therefore, the physical measurements can become tediou...

  2. Pressure control for minimizing leakage in water distribution systems

    Directory of Open Access Journals (Sweden)

    Nourhan Samir

    2017-12-01

    Full Text Available In the last decades water resources availability has been a major issue on the international agenda. In a situation of worsening scarcity of water resources and the rapidly increasing of water demands, the state of water losses management is part of man’s survival on earth. Leakage in water supply networks makes up a significant amount, sometimes more than 70% of the total water losses. The best practices suggest that pressure management is one of the most effective way to reduce the amount of leakage in a water distribution system. The approach presented in this study is aimed at modeling leakage as a function of pressure and pipe length, calibrating leakage coefficient, using fixed pressure reducing valves (PRVs to develop pressure fluctuation and developing WaterCAD scenarios to minimize leakage through the most effective settings of PRVs. This approach was applied on a district metered area (DMA in Alexandria, Egypt. The application of this approach produced some encouraging results, where the leakage through DMA was dropped by 37% for the best scenario. Thus, this approach is recommended as a decision support tool for determining a desirable solution for leakage reduction. Keywords: District measure area, Infrastructure leakage index, Leakage, Pressure management, Water supply networks

  3. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  4. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV...

  5. Vertebroplasty: Magnetic Resonance Findings Related to Cement Leakage Risk

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Y.H.; Han, D.; Cha, J.H.; Seong, C.K.; Kim, J.; Choi, Y.H. [Dept. of Radiology, Seoul Municipal Boramae Hospital, Seoul (Korea, republic of)

    2007-04-15

    Purpose: To find magnetic resonance (MR) findings predicting cement leakage in patients receiving percutaneous vertebroplasty (PVP) due to osteoporotic compression fractures. Material and Methods: MR was done in 43 patients (age 52-89 years) before PVP (56 vertebrae), which was done via a bipedicular approach with fluoroscopic monitoring. Shortly after the procedure, a non-contrast-enhanced computed tomography (CT) scan was done at the vertebroplasty sites for evaluation of bone cement leakage. The following MR findings of fractured vertebral bodies were retrospectively reviewed for correlation with leakage risk: severity of bone-marrow edema, presence of a T2-weighted low-signal-intensity line, percentage residual vertebral body height, presence of either a vacuum or cystic change within the vertebral body, and presence of a cortical disruption. Results: After PVP, cement leakage was detected in 35 vertebrae (62.5%). Leakage was most frequently observed in the anterior external vertebral venous plexus (46%). Cement leakage rate increased when there was a cortical disruption (P = 0.037), especially at the endplates, while it decreased when there was a vacuum or a cystic change within the fractured vertebra (P 0.019). Other MR findings were not related to the risk of cement leakage. Conclusion: The risk of cement leakage in PVP increases when MR shows cortical disruption in a fractured vertebral body, especially at the endplates. It decreases when MR shows a vacuum or cystic change within the body. Keywords Cement leakage, MR imaging, spine, vertebroplasty.

  6. Evaluation of the leakage behavior of inflatable seals subject to severe accident conditions

    International Nuclear Information System (INIS)

    Parks, M.B.

    1989-11-01

    Sandia National Laboratories, under the sponsorship of the United States Nuclear Regulatory Commission, is currently developing test validated methods to predict the pressure capacity of light water reactor containment buildings when subjected to postulated severe accident conditions. These conditions are well beyond the design basis. Scale model tests of steel and reinforced concrete containments have been conducted as well as tests of typical containment penetrations. As a part of this effort, a series of tests was recently conducted to determine the leakage behavior of inflatable seals. These seals are used to prevent leakage around personnel and escape lock doors of some containments. The results of the inflatable seals tests are the subject of this report. Inflatable seals were tested at both room temperature and at elevated temperatures representative of postulated severe accident conditions. Both aged (radiation and thermal) and unaged seals were included in the test program. The internal seal pressure at the beginning of each test was varied to cover the range of seal pressures actually used in containments. For each seal pressure level, the external (containment) pressure was increased until significant leakage past the seals was observed. Parameters that were monitored and recorded during the tests were the internal seal pressure, chamber pressure, leakage past the seals, and temperature of the test chamber and fixture to which the seals were attached. 8 refs., 34 figs., 7 tabs

  7. Analysis of Chlorine Gas Incident Simulation and Dispersion Within a Complex and Populated Urban Area Via Computation Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    Eslam Kashi

    2015-04-01

    Full Text Available In some instances, it is inevitable that large amounts of potentially hazardous chemicals like chlorine gas are stored and used in facilities in densely populated areas. In such cases, all safety issues must be carefully considered. To reach this goal, it is important to have accurate information concerning chlorine gas behaviors and how it is dispersed in dense urban areas. Furthermore, maintaining adequate air movement and the ability to purge ambient from potential toxic and dangerous chemicals like chlorine gas could be helpful. These are among the most important actions to be taken toward the improvement of safety in a big metropolis like Tehran. This paper investigates and analyzes chlorine gas leakage scenarios, including its dispersion and natural air ventilation  effects on how it might be geographically spread in a city, using computational  fluid dynamic (CFD. Simulations of possible hazardous events and solutions for preventing or reducing their probability are presented to gain a better insight into the incidents. These investigations are done by considering hypothetical scenarios which consist of chlorine gas leakages from pipelines or storage tanks under different conditions. These CFD simulation results are used to investigate and analyze chlorine gas behaviors, dispersion, distribution, accumulation, and other possible hazards by means of a simplified CAD model of an urban area near a water-treatment facility. Possible hazards as well as some prevention and post incident solutions are also suggested.

  8. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...... in the size of the secret and observables, are cumbersome to compute and store, encode both the behavior of the system and assumptions about the attacker, and assume an input-output behavior of the system. For these reasons we propose to model the systemattacker scenario with Markovian models. We show...

  9. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  10. Understanding Magnetic Flux Leakage signals from gouges

    Energy Technology Data Exchange (ETDEWEB)

    Clapham, Lynann; Babbar, Vijay; Dien Chen, Jian [Applied Magnetics Group, Department of Physics, Queen' s University, Kingston, Ontario (Canada)], email: lynann@physics.queensu.ca; Alexander, Chris [Stress Engineering Services Inc., Houston, Texas (United States)

    2010-07-01

    Mechanical damage in pipelines is an important issue as it can lead to immediate or delayed failures. The magnetic flux leakage (MFL) method can be used to locate and characterize mechanical damage in pipelines. The purpose of this study is to get a better understanding of how MFL signals arise from pipeline gouges. Experimental MFL measurements were carried out on X60 grade pipe sections where a defect set of 10 gouges had been introduced; measurements were conducted on both internal and external pipe wall surface. Results showed that deformation and residual stress due to a gouge are mostly situated at the outer wall surface and that MFL measurements detected it from the inside and a model was developed to account for MFL axial dipole signal. This study brought new information on MFL signals and further work will be undertaken to completely understand how MFL signals arise from pipe gouge.

  11. Development of leakage monitoring system using radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. C.; Lee, D. S. [Seoil College, Seoul (Korea); Cho, Y. S. [Konyang University, Nonsan (Korea); Shin, S. K. [Sungkyunkwan Univ., Seoul (Korea)

    2000-04-01

    This study is to development the potable neutron back-scattering gauge for leakage and detecting liquid interface of an oil and liquid tank, using a radioisotopes. For this purpose, small sized, light weight potable gauge is to be designed as to develope neutron shielding mechanism, low power supply circuit, high voltage circuit, measurement circuit, and operating handle etc. The user will be able to set the duration of the time interval, the scale, the high voltage, the threshold, the channel window, the selection whether the data storage or not, the selection whether the scale, high voltage, threshold and window fix or not at any time. The counted pulse will be displayed with the numerical value and the line bar. The gauge will be able to connect to an IBM compatible PC via a serial port, power will be supplied by internal battery. 9 refs., 28 figs., 10 tabs. (Author)

  12. Leakage current in high-purity germanium detectors with amorphous semiconductor contacts

    Science.gov (United States)

    Looker, Q.; Amman, M.; Vetter, K.

    2015-03-01

    Amorphous semiconductor electrical contacts on high-purity Ge radiation detectors have become a valuable technology because they are simple to fabricate, result in thin dead layers, block both electron and hole injection, and can readily be finely segmented as needed for applications requiring imaging or particle tracking. Though significant numbers of detectors have been successfully produced for a variety of applications using the amorphous semiconductor contact technology, there remains a need to better understand the dependence of performance characteristics, particularly leakage current, on the fabrication process parameters so that the performance can be better optimized. To this end, we have performed a systematic study of leakage current on RF-sputter-deposited amorphous-Ge (a-Ge) and amorphous-Si (a-Si) contacts as a function of process and operational parameters including sputter gas pressure and composition, number of detector temperature cycles, and time spent at room temperature. The study focused primarily on the current resulting from electron injection at the contact. Significant findings from the study include that a-Si produces lower electron injection than a-Ge, the time the detector spends at room temperature rather than the number of temperature cycles experienced by the detector is the primary factor associated with leakage current change when the detector is warmed, and the time stability of the a-Ge contact depends on the sputter gas pressure with a higher pressure producing more stable characteristics.

  13. Nitrogen gas extinguisher system as a countermeasure against a sodium fire at Monju

    International Nuclear Information System (INIS)

    Hasegawa, M.; Ikeda, M.; Kikuchi, H.

    2001-01-01

    Monju is a prototype sodium cooled FBR in Japan and occurred a sodium leakage incident in the secondary heat transport system on Dec. 8, 1995. The cause of the sodium leakage was a thermocouple well tube failure resulting from high cycle fatigue due to flow-induced vibration. The investigative research revealed that this type of flow-induced vibration was not a well-known Von Karman vortex shedding, but a symmetric vortex shedding. In the light of lessons from the sodium leakage incident, Monju will take several improvements in order to enhance the safety and reliability of the plant. A nitrogen gas extinguisher system will be installed at Monju as one of countermeasures against sodium fires. The basic design specifications of the system were determined by some experiments. Three kinds of experiment were conducted with the object of confirming; (1) an oxygen concentration to suppress the sodium fire, (2) a nitrogen gas mixing efficiency to decrease the oxygen concentration, and (3) a nitrogen gas feed rate to prevent air in-leak from the outside to keep the low oxygen atmosphere. This paper reports these tests which were performed to determine the design specification of the system. (authors)

  14. Ageing studies for the ATLAS MDT muonchambers and development of a gas filter to prevent drift tube ageing

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, S.

    2008-01-15

    The muon spectrometer of the ATLAS detector, which is currently assembled at the LHC accelerator at CERN, uses drift tubes as basic detection elements over most of the solid angle. The performance of these monitored drift tubes (MDTs), in particular their spatial resolution of 80 {mu}m, determines the precision of the spectrometer. If ageing effects occur, the precision of the drift tubes will be degraded. Hence ageing effects have to be minimized or avoided altogether if possible. Even with a gas mixture of Ar:CO{sub 2}=93:7, which was selected for its good ageing properties, ageing effects were observed in test systems. They were caused by small amounts of impurities, in particular volatile silicon compounds. Systematic studies revealed the required impurity levels deteriorating the drift tubes to be well below 1 ppm. Many components of the ATLAS MDT gas system are supplied by industry. In a newly designed ageing experiment in Freiburg these components were validated for their use in ATLAS. With a fully assembled ATLAS gas distribution rack as test component ageing effects were observed. It was therefore decided to install gas filters in the gas distribution lines to remove volatile silicon compounds efficiently from the gas mixture. Finally a filter was designed that can adsorb up to 5.5 g of volatile silicon compounds, hereby reducing the impurities in the outlet gas mixture to less than 30 ppb. (orig.)

  15. Simulation of high consequence areas for gas pipelines

    Directory of Open Access Journals (Sweden)

    Orlando Díaz-Parra

    2018-01-01

    Full Text Available The gas pipeline is used for the transport of natural gas at a great distance. Risks derived from the handling of a combustible material transported under high pressure, by pipelines that pass close to where people live, makes it necessary to adopt prevention, mitigation and control measures to reduce the effect in case of ignition of a gas leak. This work shows the development of a new mathematical model to determine areas of high consequence and their application, using widely available and easy to use software, such as Google Earth and Excel, to determine and visualize the area up to which the level of radiation can affect the integrity of people and buildings. The model takes into account the pressure drop into the gas pipeline from the compression station, the gas leakage rate and possible forms of gas ignition. This development is an alternative to the use of specialized software and highly trained personnel. The simulation is applied to a traced of the Miraflores-Tunja gas pipeline, using a macro developed in Excel to determine the impact area and compare it with the coordinates of the vulnerable areas. The zones where these areas intersect are constituted in high consequence areas and are identified along with the sections of the pipeline that affect them, to provide the operator with a risk analysis tool for the determination and visualization of the gas pipeline and its environment.

  16. The root caused analysis of leakaged heat exchanger tube; Ursachenanalyse einer Leckage an einem Waermeuebertraegerrohr

    Energy Technology Data Exchange (ETDEWEB)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif [Universiti Malaysia Perlis (UniMAP) (Malaysia). Center of Excellence Geopolymer and Green Technology (CEGeoGTech); Harun, Mohd; Zayid, Hafizal [Malaysian Nuclear Agency, Selangor (Malaysia). Industry Technology Div.; Noor, Mazlee Mohd [Universiti Malaysia Perlis (UniMAP) (Malaysia). School of Materials Engineering

    2015-05-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  17. Forecast and Prevention of Coal and Gas Outbursts in the Case of Application of a New Mining Method - Drilling of a Coal Pillar

    Directory of Open Access Journals (Sweden)

    Vlastimil Hudeček

    2010-10-01

    Full Text Available Coal and gas outbursts are one of risk factors accompanying the mining of coal in low seams in the Ostrava-Karviná Coalfield.At the use of the method of longwall mining, all coal reserves have not been mined out owing to tectonic faults. For mining outthe residual reserves, the application of a new mining method - drilling of a coal pillar was proposed.The method of mining of a coal seam utilizing long large diameter boreholes is verified in the Paskov Mine (company OKD, JSC –Czech Republic under conditions of rock mass with hazard of rock and gas outbursts in localities of residual pillars left in seams afterfinishing the mining operations performed with using the classical method of longwall working along the strike. [5]Forecast and preventive measures applied to the verification of the new method were based on previous experience withthe mining of seams with hazard of coal and gas outbursts. They accepted fully valid legislation, i.e. Ordinance of Ostrava RegionalMining Authority No. 3895/2002 and supplementary materials (Instructions and Guidelines. The proposed measures respectedthe character of the method being verified. [4]For all areas being mined, projects containing also chapters specifying the problems of ensuring the safety of mining worksand operation under conditions of hazard of coal and gas outbursts were prepared.In the contributions, basic proposals for the principles of coal and gas outburst forecast and prevention when applying the newmining method – drilling of a coal pillar are presented

  18. Rubber contact mechanics: adhesion, friction and leakage of seals.

    Science.gov (United States)

    Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J

    2017-12-13

    We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.

  19. Potential acidification impacts on zooplankton in CCS leakage scenarios

    International Nuclear Information System (INIS)

    Halsband, Claudia; Kurihara, Haruko

    2013-01-01

    Highlights: • Effects of CCS techniques and ocean acidification on zooplankton are under-studied. • Vulnerable zooplankton are meso-, bathypelagic and vertically migrating species. • Impacts include impaired calcification, reproduction, development and survival. • Need for modelling studies combining physico-chemical with ecological impacts. -- Abstract: Carbon capture and storage (CCS) technologies involve localized acidification of significant volumes of seawater, inhabited mainly by planktonic species. Knowledge on potential impacts of these techniques on the survival and physiology of zooplankton, and subsequent consequences for ecosystem health in targeted areas, is scarce. The recent literature has a focus on anthropogenic greenhouse gas emissions into the atmosphere, leading to enhanced absorption of CO 2 by the oceans and a lowered seawater pH, termed ocean acidification. These studies explore the effects of changes in seawater chemistry, as predicted by climate models for the end of this century, on marine biota. Early studies have used unrealistically severe CO 2 /pH values in this context, but are relevant for CCS leakage scenarios. Little studied meso- and bathypelagic species of the deep sea may be especially vulnerable, as well as vertically migrating zooplankton, which require significant residence times at great depths as part of their life cycle

  20. 78 FR 54432 - Development of Inward Leakage Standards for Half-Mask Air-Purifying Particulate Respirators

    Science.gov (United States)

    2013-09-04

    ...)? 3. Does your company use a panel or portion of a panel to develop respirators for a defined user... implementation of fit testing standards for defined user groups? 4. Does your company use a panel or a portion of... Control and Prevention (CDC) announces a public meeting concerning inward leakage performance requirements...

  1. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  2. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  3. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  4. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  5. Failure analysis of leakage current in plastic encapsulated packages

    Science.gov (United States)

    Hu, S. J.; Cheang, F. T.

    1990-11-01

    Plastic encapsulated packages exhibit high leakage currents after a few hundred hours in the steam pressure pot test (SPP). The present study investigates two possible causes of leakage current. These are: (a) mold compound, (b) the polyimide tape used for co-planarity of lead frame fingers. The results of this study indicate that the leakage cur-rent is independent of the frame and is not caused by the mold compound. The data indicates that it is the ionic content and acrylic-based adhesive layer of the polyimide tape which cause the leakage current. To eliminate the leakage current, polyimide tape with low ionic content and non acrylic-based adhesive should be used.

  6. Hydrate prevention during formation test of gas in deep water; Prevencao de formacao de hidratos durante teste de formacao de poco de gas em lamina d'agua profunda

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Renato Cunha [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2008-07-01

    This work shows a scenery of formation test in deep water, for a well of gas, for which, there were made simulations with objective of identifying possible pairs of points (Pressure x Temperature), favorable to the hydrates formation. Besides, they were made comparisons of the values obtained in the simulation with the values registered during the formation test for the well Alfa of the field Beta. Of ownership of those information, we made an evaluation of the real needs of injection of inhibitors with intention of preventing the hydrates formation in each phase of the test. In an including way, the work has as objective recommends the volumes of hydrates inhibitors to be injected in each phase of a test of formation of well of gas in deep water, in way to assure that the operations are made without there is risk of hydrates formation. (author)

  7. Hydrates prevention during deep-water formation gas well test; Prevencao de formacao de hidratos durante teste de formacao de poco de gas em lamina d'agua profunda

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Renato Cunha [Unidade de Operacoes de Exploracao e Producao do Espirito Santo. Engenharia de Producao. Gerencia de Engenharia de Poco, ES (Brazil)], e-mail: renatocr@petrobras.com.br; Freitas, Alexandre Mussumeci Valim de [Centro de Pesquisas da Petrobras (CENPES). Gerencia de Tecnologia de Elevacao e Escoamento da Producao (Brazil)], e-mail: amfreitas@petrobras.com.br; Nishimura, Nelson Satiro [E and P Engenharia de Producao. Reservas e Reservatorios. Gerencia de Avaliacao de Reservatorios (Brazil)], e-mail: nishimura@petrobras.com.br

    2010-06-15

    This study examines the situation of a deep water formation test for a gas well in which simulations were made to identify possible pairs of points (Pressure versus Temperature), favorable to hydrate formation. Furthermore, the values obtained in the simulation were compared with the values registered during the formation test for the Alfa well in the Beta Field. With this information, an evaluation was made of the necessity to inject inhibitors intended to prevent hydrate formation in each test phase. In a wider sense, the study's objective was to recommend the volumes of hydrate inhibitors to be injected in each phase of a deep water formation test of a gas well to assure the operation be done without the risk of hydrate formation. (author)

  8. Reduced-Order Model for Leakage Through an Open Wellbore from the Reservoir due to Carbon Dioxide Injection

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Lehua [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Oldenburg, Curtis M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-07-26

    Potential CO2 leakage through existing open wellbores is one of the most significant hazards that need to be addressed in geologic carbon sequestration (GCS) projects. In the framework of the National Risk Assessment Partnership (NRAP) which requires fast computations for uncertainty analysis, rigorous simulation of the coupled wellbore-reservoir system is not practical. We have developed a 7,200-point look-up table reduced-order model (ROM) for estimating the potential leakage rate up open wellbores in response to CO2 injection nearby. The ROM is based on coupled simulations using T2Well/ECO2H which was run repeatedly for representative conditions relevant to NRAP to create a look-up table response-surface ROM. The ROM applies to a wellbore that fully penetrates a 20-m thick reservoir that is used for CO2 storage. The radially symmetric reservoir is assumed to have initially uniform pressure, temperature, gas saturation, and brine salinity, and it is assumed these conditions are held constant at the far-field boundary (100 m away from the wellbore). In such a system, the leakage can quickly reach quasi-steady state. The ROM table can be used to estimate both the free-phase CO2 and brine leakage rates through an open well as a function of wellbore and reservoir conditions. Results show that injection-induced pressure and reservoir gas saturation play important roles in controlling leakage. Caution must be used in the application of this ROM because well leakage is formally transient and the ROM lookup table was populated using quasi-steady simulation output after 1000 time steps which may correspond to different physical times for the various parameter combinations of the coupled wellbore-reservoir system.

  9. Preventive, reducing and compensation actions for environmental impacts of Coari-Manaus gas pipeline; Medidas preventivas, mitigadoras e compensatorias de impactos socioambientais do Projeto Gasoduto Coari-Manaus

    Energy Technology Data Exchange (ETDEWEB)

    Mannarino, Ronaldo P. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Rangel, Antonio Carlos F. [PETROBRAS, Rio de Janeiro, RJ (Brazil). Coordenacao de Projetos Especiais da Area de Gas e Energia

    2004-07-01

    The estimated reserve of natural gas of 124,5 billions m3 existent in the Solimoes basin it's the big thermometrical market existent on the Manaus city, actually supplied with liquid fuels, they had become economically viable the construction of a gas pipeline establishing connection it offers of the demand. However, given the complexity of the Amazonian landscape, the ambient aspects need to be studied with use of tools and methodologies integrators, also contemplating the social aspects. A multi discipline group of researches, led for Centro de Ciencias Ambientais from Universidade Federal do Amazonas - CCA/UFAM they had carried through diagnosis of the influences area of Coari-Manaus gas pipeline had as base research developed for PIATAM (Potenciais Impactos e Riscos Ambientais do Transporte de Petroleo e Gas no Amazonas) project during 24 months in the region enclosed for the tracing considered. During the study of UFAM and in the Official Audiences of the licence process had done consultation for the involved communities, and the results served of base for proposal to the prevention of negative impacts, reduce and compensation of inevitable impacts. The legal and institutional requisites are argued and are considered a way to consolidate the existing regulation on the subject having as basic premise the compatibility of the local and regional interests with the necessity of economic development of the country. (author)

  10. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K.; Otruba, J. [Nuclear Research Inst., Rez (Switzerland)

    1997-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  11. Leakage rate from LOCA-aged inflatable airlock seals Pickering NGS 'B' personnel doors

    International Nuclear Information System (INIS)

    Fayle, G.W.; Cordingley, D.C.

    1985-01-01

    In order to demonstrate to the Atomic Energy Control Board that an air-lock inflatable seal will function after a LOCA exposure, an inflatable seal intended for personnel doors at the Pickering NGS 'B' was exposed to the thermal/moisture conditions of the LOCA requirement. While attending to determine the post-LOCA leakage rate it was found that additional leaks developed during each post-LOCA inflation/deflation cycle. The seal had been significantly and irreparably deteriorated by the LOCA exposure. The test has demonstrated that this type of LOCA exposed seal should not be expected to withstand either additional pressure above 207 kPa or additional inflation/deflation cycling. A higher inflation pressure and/or cycling will reduce the likelihood of a post-LOCA seal retaining an inflation pressure sufficient to prevent leakage across the seal

  12. Agulhas leakage as a key process in the modes of Quaternary climate changes.

    Science.gov (United States)

    Caley, Thibaut; Giraudeau, Jacques; Malaizé, Bruno; Rossignol, Linda; Pierre, Catherine

    2012-05-01

    Heat and salt transfer from the Indian Ocean to the Atlantic Ocean (Agulhas leakage) has an important effect on the global thermohaline circulation and climate. The lack of long transfer record prevents elucidation of its role on climate changes throughout the Quaternary. Here, we present a 1,350-ka accumulation rate record of the planktic foraminiferal species Globorotalia menardii. We demonstrate that, according to previous assumptions, the presence and reseeding of this fauna in the subtropical southeast Atlantic was driven by interocean exchange south of Africa. The Agulhas transfer strengthened at glacial ice-volume maxima for every glacial-interglacial transition, with maximum reinforcements organized according to a 400-ka periodicity. The long-term dynamics of Agulhas leakage may have played a crucial role in regulating meridional overturning circulation and global climate changes during the Mid-Brunhes event and the Mid-Pleistocene transition, and could also play an important role in the near future.

  13. WWER steam generator tube structural and leakage integrity

    International Nuclear Information System (INIS)

    Splichal, K.; Krhounek, Vl.; Otruba, J.; Ruscak, M.

    1998-01-01

    The integrity of heat exchange tubes may influence the lifetime of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirements are to assure very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evaluation and heat exchange tubes plugging. The stress corrosion cracking and pitting are the main corrosion damages of WWER heat exchange tubes and are initiated from the outer surface. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through wall cracks, oriented preferentially in the axial direction. The paper presents the leakage and plugging limits for WWER steam generators, which have been determined from leak tests and burst tests. The tubes with axial part-through and through-wall defects have been used. The permissible value of primary to secondary leak rate was evaluated with respect to permissible axial through-wall defect size of WWER 440 and 1000 steam generator tubes. Blocking of the tube cracks by corrosion product particles and other compounds reduces the primary to secondary leak rate. The plugging limits involve the following factors: permissible tube wall thickness which determine further operation of the tubes with defects and assures their integrity under operating conditions and permissible size of a through-wall crack which is sufficiently stable under normal and accident conditions in relation to the critical crack length. For the evaluation of burst test of heat exchange tubes with longitudinal through-wall defects the instability criterion has been used and the dependence of the normalised burst pressure on the normalised length of an axial through-wall defect has been determined. The validity of the criterion of instability for WWER tubes with through

  14. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  15. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  16. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration

  17. Geochemical Implications of CO2 Leakage Associated with Geologic Storage: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Omar R.; Qafoku, Nikolla; Cantrell, Kirk J.; Brown, Christopher F.

    2012-07-09

    Leakage from deep storage reservoirs is a major risk factor associated with geologic sequestration of carbon dioxide (CO2). Different scientific theories exist concerning the potential implications of such leakage for near-surface environments. The authors of this report reviewed the current literature on how CO2 leakage (from storage reservoirs) would likely impact the geochemistry of near surface environments such as potable water aquifers and the vadose zone. Experimental and modeling studies highlighted the potential for both beneficial (e.g., CO2 re sequestration or contaminant immobilization) and deleterious (e.g., contaminant mobilization) consequences of CO2 intrusion in these systems. Current knowledge gaps, including the role of CO2-induced changes in redox conditions, the influence of CO2 influx rate, gas composition, organic matter content and microorganisms are discussed in terms of their potential influence on pertinent geochemical processes and the potential for beneficial or deleterious outcomes. Geochemical modeling was used to systematically highlight why closing these knowledge gaps are pivotal. A framework for studying and assessing consequences associated with each factor is also presented in Section 5.6.

  18. Leakage risk assessment of the In Salah CO2 storage project: Applying the Certification Framework in a dynamic context.

    Energy Technology Data Exchange (ETDEWEB)

    Oldenburg, C.M.; Jordan, P.D.; Nicot, J.-P.; Mazzoldi, A.; Gupta, A.K.; Bryant, S.L.

    2010-08-01

    The Certification Framework (CF) is a simple risk assessment approach for evaluating CO{sub 2} and brine leakage risk at geologic carbon sequestration (GCS) sites. In the In Salah CO{sub 2} storage project assessed here, five wells at Krechba produce natural gas from the Carboniferous C10.2 reservoir with 1.7-2% CO{sub 2} that is delivered to the Krechba gas processing plant, which also receives high-CO{sub 2} natural gas ({approx}10% by mole fraction) from additional deeper gas reservoirs and fields to the south. The gas processing plant strips CO{sub 2} from the natural gas that is then injected through three long horizontal wells into the water leg of the Carboniferous gas reservoir at a depth of approximately 1,800 m. This injection process has been going on successfully since 2004. The stored CO{sub 2} has been monitored over the last five years by a Joint Industry Project (JIP) - a collaboration of BP, Sonatrach, and Statoil with co-funding from US DOE and EU DG Research. Over the years the JIP has carried out extensive analyses of the Krechba system including two risk assessment efforts, one before injection started, and one carried out by URS Corporation in September 2008. The long history of injection at Krechba, and the accompanying characterization, modeling, and performance data provide a unique opportunity to test and evaluate risk assessment approaches. We apply the CF to the In Salah CO{sub 2} storage project at two different stages in the state of knowledge of the project: (1) at the pre-injection stage, using data available just prior to injection around mid-2004; and (2) after four years of injection (September 2008) to be comparable to the other risk assessments. The main risk drivers for the project are CO{sub 2} leakage into potable groundwater and into the natural gas cap. Both well leakage and fault/fracture leakage are likely under some conditions, but overall the risk is low due to ongoing mitigation and monitoring activities. Results of

  19. CFD simulation of a screw compressor including leakage flows and rotor heating

    Science.gov (United States)

    Spille-Kohoff, Andreas, Dr.; Hesse, Jan; El Shorbagy, Ahmed

    2015-08-01

    Computational Fluid Dynamics (CFD) simulations have promising potential to become an important part in the development process of positive displacement (PD) machines. CFD delivers deep insights into the flow and thermodynamic behaviour of PD machines. However, the numerical simulation of such machines is more complex compared to dynamic pumps like turbines or fans. The fluid transport in size-changing chambers with very small clearances between the rotors, and between rotors and casing, demands complex meshes that change with each time step. Additionally, the losses due to leakage flows and the heat transfer to the rotors need high-quality meshes so that automatic remeshing is almost impossible. In this paper, setup steps and results for the simulation of a dry screw compressor are shown. The rotating parts are meshed with TwinMesh, a special hexahedral meshing program for gear pumps, gerotors, lobe pumps and screw compressors. In particular, these meshes include axial and radial clearances between housing and rotors, and beside the fluid volume the rotor solids are also meshed. The CFD simulation accounts for gas flow with compressibility and turbulence effects, heat transfer between gas and rotors, and leakage flows through the clearances. We show time- resolved results for torques, forces, interlobe pressure, mass flow, and heat flow between gas and rotors, as well as time- and space-resolved results for pressure, velocity, temperature etc. for different discharge ports and working points of the screw compressor. These results are also used as thermal loads for deformation simulations of the rotors.

  20. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  1. Monitoring techniques of a natural analogue for sub-seabed CO2 leakages

    OpenAIRE

    Caramanna, Giorgio; Fietzek, Peer; Maroto-Valer, Mercedes

    2011-01-01

    Carbon dioxide sequestration in sub-seafloor aims to store CO2 inside geological trapping structures below the seafloor. However there are concerns related to the possibility of leakage from the storage sites and potential consequences on the marine environment. In order to develop safe and reliable methods for CO2 monitoring, field studies were conducted in a natural analogue–an area where there is a natural release of CO2 from the seafloor. Due to the very high volume of gas emitted, ...

  2. Advanced CO2 Leakage Mitigation using Engineered Biomineralization Sealing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Spangler, Lee [Montana State Univ., Bozeman, MT (United States); Cunningham, Alfred [Montana State Univ., Bozeman, MT (United States); Phillips, Adrienne [Montana State Univ., Bozeman, MT (United States)

    2015-03-31

    This research project addresses one of the goals of the DOE Carbon Sequestration Program (CSP). The CSP core R&D effort is driven by technology and is accomplished through laboratory and pilot scale research aimed at new technologies for greenhouse gas mitigation. Accordingly, this project was directed at developing novel technologies for mitigating unwanted upward leakage of carbon dioxide (CO2) injected into the subsurface as part of carbon capture and storage (CCS) activities. The technology developed by way of this research project is referred to as microbially induced calcite precipitation (MICP).

  3. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  4. Deep Sludge Gas Release Event Analytical Evaluation

    International Nuclear Information System (INIS)

    Sams, Terry L.

    2013-01-01

    Long Abstract. Full Text. The purpose of the Deep Sludge Gas Release Event Analytical Evaluation (DSGRE-AE) is to evaluate the postulated hypothesis that a hydrogen GRE may occur in Hanford tanks containing waste sludges at levels greater than previously experienced. There is a need to understand gas retention and release hazards in sludge beds which are 200 -300 inches deep. These sludge beds are deeper than historical Hanford sludge waste beds, and are created when waste is retrieved from older single-shell tanks (SST) and transferred to newer double-shell tanks (DST).Retrieval of waste from SSTs reduces the risk to the environment from leakage or potential leakage of waste into the ground from these tanks. However, the possibility of an energetic event (flammable gas accident) in the retrieval receiver DST is worse than slow leakage. Lines of inquiry, therefore, are (1) can sludge waste be stored safely in deep beds; (2) can gas release events (GRE) be prevented by periodically degassing the sludge (e.g., mixer pump); or (3) does the retrieval strategy need to be altered to limit sludge bed height by retrieving into additional DSTs? The scope of this effort is to provide expert advice on whether or not to move forward with the generation of deep beds of sludge through retrieval of C-Farm tanks. Evaluation of possible mitigation methods (e.g., using mixer pumps to release gas, retrieving into an additional DST) are being evaluated by a second team and are not discussed in this report. While available data and engineering judgment indicate that increased gas retention (retained gas fraction) in DST sludge at depths resulting from the completion of SST 241-C Tank Farm retrievals is not expected and, even if gas releases were to occur, they would be small and local, a positive USQ was declared (Occurrence Report EM-RP--WRPS-TANKFARM-2012-0014, 'Potential Exists for a Large Spontaneous Gas Release Event in Deep Settled Waste Sludge'). The purpose of this technical

  5. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    , we use a randomized encoding and develop a method to securely refresh these encodings even in the presence of leakage. We then show that our encoding scheme exhibits an efficient additive homomorphism which can be used to protect important cryptographic tasks such as identification, signing......We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third......, the randomness that is used for certain operations comes from a simple (non-uniform) distribution. As a fundamental building block, we construct a scheme to store a cryptographic secret such that it remains information theoretically hidden, even given arbitrary continuous leakage from the storage. To this end...

  6. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  7. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  8. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  9. Microbial stimulation and succession following a test well injection simulating CO2 leakage into a shallow Newark basin aquifer.

    Science.gov (United States)

    O'Mullan, Gregory; Dueker, M Elias; Clauson, Kale; Yang, Qiang; Umemoto, Kelsey; Zakharova, Natalia; Matter, Juerg; Stute, Martin; Takahashi, Taro; Goldberg, David

    2015-01-01

    In addition to efforts aimed at reducing anthropogenic production of greenhouse gases, geological storage of CO2 is being explored as a strategy to reduce atmospheric greenhouse gas emission and mitigate climate change. Previous studies of the deep subsurface in North America have not fully considered the potential negative effects of CO2 leakage into shallow drinking water aquifers, especially from a microbiological perspective. A test well in the Newark Rift Basin was utilized in two field experiments to investigate patterns of microbial succession following injection of CO2-saturated water into an isolated aquifer interval, simulating a CO2 leakage scenario. A decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), and increased bacterial cell concentrations in the recovered water. 16S ribosomal RNA gene sequence libraries from samples collected before and after the test well injection were compared to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injections, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia and microbial taxa often noted to be associated with iron and sulfate reduction. The concurrence of increased microbial cell concentrations and rapid microbial community succession indicate significant changes in aquifer microbial communities immediately following the experimental CO2 leakage event. Samples collected one year post-injection were similar in cell number to the original background condition and community composition, although not identical, began to revert toward the pre-injection condition, indicating microbial resilience following a leakage disturbance. This study provides a first glimpse into the in situ successional response of microbial communities to CO2 leakage after subsurface

  10. An improved intrafemoral injection with minimized leakage as an orthotopic mouse model of osteosarcoma.

    Science.gov (United States)

    Sasaki, Hiromi; Iyer, Swathi V; Sasaki, Ken; Tawfik, Ossama W; Iwakuma, Tomoo

    2015-10-01

    Osteosarcoma, the most common type of primary bone cancer, is the second highest cause of cancer-related death in pediatric patients. To understand the mechanisms behind osteosarcoma progression and to discover novel therapeutic strategies for this disease, a reliable and appropriate mouse model is essential. For this purpose, osteosarcoma cells need to be injected into the bone marrow. Previously, the intratibial and intrafemoral injection methods were reported; however, the major drawback of these methods is the potential leakage of tumor cells from the injection site during or after these procedures. To overcome this, we have established an improved method to minimize leakage in an orthotopic mouse model of osteosarcoma. By taking advantage of the anatomical benefits of the femur with less bowing and larger medullary cavity than those of the tibia, osteosarcoma cells are injected directly into the femoral cavity following reaming of its intramedullary space. To prevent potential leakage of tumor cells during and after the surgery, the injection site is sealed with bone wax. This method requires a minor surgery of approximately 15min under anesthesia. Our established orthotopic osteosarcoma model could serve as a valuable and reliable tool for examining progression of various types of bone tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  12. Weak magnetic flux leakage : a possible method for studying pipeline defects located either inside or outside the structures

    OpenAIRE

    Liu, Bin; Cao, Y.; Zhang, Hai; Lin, Y. R.; Sun, W. R.; Xu, B.

    2015-01-01

    Magnetic leakage distribution results from linear defects of oil–gas pipelines in a weak magnetic field, which is modeled by the magnetic dipole theory. The analysis is useful for the identification of defects located either inside or outside the pipelines. The results indicate that the radial signals of inside–outside defects can be clearly distinguished, and the axial signals are basically the same in a weak magnetic field. The theoretical and the experimental results are very consistent.

  13. Detail Design of the hydrogen system and the gas blanketing system for the HANARO-CNS

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung Woon; Kim, Hark Rho; Kim, Young Ki; Wu, Sang Ik; Kim, Bong Su; Lee, Yong Seop

    2007-04-15

    The cold neutron source (CNS), which will be installed in the vertical CN hole of the reflector tank at HANARO, makes thermal neutrons to moderate into the cold neutrons with the ranges of 0.1 {approx} 10 meV passing through a moderator at about 22K. A moderator to produce cold neutrons is liquid hydrogen, which liquefies by the heat transfer with cryogenic helium flowing from the helium refrigeration system (HRS). Because of its installed location, the hydrogen system is designed to be surrounded by the gas blanketing system to notify the leakage on the system and to prevent hydrogen leakage out of the CNS. The hydrogen system, consisted of hydrogen charging unit, hydrogen storage unit, hydrogen buffer tank, and hydrogen piping, is designed to smoothly and safely supply hydrogen to and to draw back hydrogen from the IPA of the CNS under the HRS operation mode. Described is that calculation for total required hydrogen amount in the CNS as well as operation schemes of the hydrogen system. The gas blanketing system (GBS) is designed for the supply of the compressed nitrogen gas into the air pressurized valves for the CNS, to isolate the hydrogen system from the air and the water, and to prevent air or water intrusion into the vacuum system as well as the hydrogen system. All detail descriptions are shown inhere as well as the operation scheme for the GBS.

  14. Sulforaphane induces phase II detoxication enzymes in mouse skin and prevents mutagenesis induced by a mustard gas analog.

    Science.gov (United States)

    Abel, E L; Boulware, S; Fields, T; McIvor, E; Powell, K L; DiGiovanni, J; Vasquez, K M; MacLeod, M C

    2013-02-01

    Mustard gas, used in chemical warfare since 1917, is a mutagenic and carcinogenic agent that produces severe dermal lesions for which there are no effective therapeutics; it is currently seen as a potential terrorist threat to civilian populations. Sulforaphane, found in cruciferous vegetables, is known to induce enzymes that detoxify compounds such as the sulfur mustards that react through electrophilic intermediates. Here, we observe that a single topical treatment with sulforaphane induces mouse epidermal levels of the regulatory subunit of glutamate-cysteine ligase, the rate-limiting enzyme in glutathione biosynthesis, and also increases epidermal levels of reduced glutathione. Furthermore, a glutathione S-transferase, GSTA4, is also induced in mouse skin by sulforaphane. In an in vivo model in which mice are given a single mutagenic application of the sulfur mustard analog 2-(chloroethyl) ethyl sulfide (CEES), we now show that therapeutic treatment with sulforaphane abolishes the CEES-induced increase in mutation frequency in the skin, measured four days after exposure. Sulforaphane, a natural product currently in clinical trials, shows promise as an effective therapeutic against mustard gas. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Tuning a High Transmission Ion Guide to Prevent Gas-Phase Proton Exchange During H/D Exchange MS Analysis

    Science.gov (United States)

    Guttman, Miklos; Wales, Thomas E.; Whittington, Dale; Engen, John R.; Brown, Jeffery M.; Lee, Kelly K.

    2016-04-01

    Hydrogen/deuterium exchange (HDX) mass spectrometry (MS) for protein structural analysis has been adopted for many purposes, including biopharmaceutical development. One of the benefits of examining amide proton exchange by mass spectrometry is that it can readily resolve different exchange regimes, as evidenced by either binomial or bimodal isotope patterns. By careful analysis of the isotope pattern during exchange, more insight can be obtained on protein behavior in solution. However, one must be sure that any observed bimodal isotope patterns are not artifacts of analysis and are reflective of the true behavior in solution. Sample carryover and certain stationary phases are known as potential sources of bimodal artifacts. Here, we describe an additional undocumented source of deuterium loss resulting in artificial bimodal patterns for certain highly charged peptides. We demonstrate that this phenomenon is predominantly due to gas-phase proton exchange between peptides and bulk solvent within the initial stages of high-transmission conjoined ion guides. Minor adjustments of the ion guide settings, as reported here, eliminate the phenomenon without sacrificing signal intensity. Such gas-phase deuterium loss should be appreciated for all HDX-MS studies using such ion optics, even for routine studies not focused on interpreting bimodal spectra.

  16. Sulforaphane induces phase II detoxication enzymes in mouse skin and prevents mutagenesis induced by a mustard gas analog

    Energy Technology Data Exchange (ETDEWEB)

    Abel, E.L. [Department of Molecular Carcinogenesis, The University of Texas MD Anderson Cancer Center, Science Park, Smithville, TX 78957 (United States); Boulware, S. [Division of Pharmacy and Toxicology, College of Pharmacy, The University of Texas at Austin, Dell Pediatric Research Institute, 1400 Barbara Jordan Blvd., Austin, TX 78723 (United States); Fields, T.; McIvor, E.; Powell, K.L. [Department of Molecular Carcinogenesis, The University of Texas MD Anderson Cancer Center, Science Park, Smithville, TX 78957 (United States); DiGiovanni, J.; Vasquez, K.M. [Division of Pharmacy and Toxicology, College of Pharmacy, The University of Texas at Austin, Dell Pediatric Research Institute, 1400 Barbara Jordan Blvd., Austin, TX 78723 (United States); MacLeod, M.C., E-mail: mcmacleod@mdanderson.org [Department of Molecular Carcinogenesis, The University of Texas MD Anderson Cancer Center, Science Park, Smithville, TX 78957 (United States)

    2013-02-01

    Mustard gas, used in chemical warfare since 1917, is a mutagenic and carcinogenic agent that produces severe dermal lesions for which there are no effective therapeutics; it is currently seen as a potential terrorist threat to civilian populations. Sulforaphane, found in cruciferous vegetables, is known to induce enzymes that detoxify compounds such as the sulfur mustards that react through electrophilic intermediates. Here, we observe that a single topical treatment with sulforaphane induces mouse epidermal levels of the regulatory subunit of glutamate-cysteine ligase, the rate-limiting enzyme in glutathione biosynthesis, and also increases epidermal levels of reduced glutathione. Furthermore, a glutathione S-transferase, GSTA4, is also induced in mouse skin by sulforaphane. In an in vivo model in which mice are given a single mutagenic application of the sulfur mustard analog 2-(chloroethyl) ethyl sulfide (CEES), we now show that therapeutic treatment with sulforaphane abolishes the CEES-induced increase in mutation frequency in the skin, measured four days after exposure. Sulforaphane, a natural product currently in clinical trials, shows promise as an effective therapeutic against mustard gas. -- Highlights: ► Sulforaphane induces increased levels of glutathione in mouse skin. ► Sulforaphane induces increased levels of GSTA4 in mouse skin. ► Sulforaphane, applied after CEES-treatment, completely abolishes CEES-mutagenesis. ► The therapeutic effect may suggest a long biological half-life for CEES in vivo.

  17. Sulforaphane induces phase II detoxication enzymes in mouse skin and prevents mutagenesis induced by a mustard gas analog

    International Nuclear Information System (INIS)

    Abel, E.L.; Boulware, S.; Fields, T.; McIvor, E.; Powell, K.L.; DiGiovanni, J.; Vasquez, K.M.; MacLeod, M.C.

    2013-01-01

    Mustard gas, used in chemical warfare since 1917, is a mutagenic and carcinogenic agent that produces severe dermal lesions for which there are no effective therapeutics; it is currently seen as a potential terrorist threat to civilian populations. Sulforaphane, found in cruciferous vegetables, is known to induce enzymes that detoxify compounds such as the sulfur mustards that react through electrophilic intermediates. Here, we observe that a single topical treatment with sulforaphane induces mouse epidermal levels of the regulatory subunit of glutamate-cysteine ligase, the rate-limiting enzyme in glutathione biosynthesis, and also increases epidermal levels of reduced glutathione. Furthermore, a glutathione S-transferase, GSTA4, is also induced in mouse skin by sulforaphane. In an in vivo model in which mice are given a single mutagenic application of the sulfur mustard analog 2-(chloroethyl) ethyl sulfide (CEES), we now show that therapeutic treatment with sulforaphane abolishes the CEES-induced increase in mutation frequency in the skin, measured four days after exposure. Sulforaphane, a natural product currently in clinical trials, shows promise as an effective therapeutic against mustard gas. -- Highlights: ► Sulforaphane induces increased levels of glutathione in mouse skin. ► Sulforaphane induces increased levels of GSTA4 in mouse skin. ► Sulforaphane, applied after CEES-treatment, completely abolishes CEES-mutagenesis. ► The therapeutic effect may suggest a long biological half-life for CEES in vivo.

  18. The use of tracers to assess leakage from the sequestration of CO2 in a depleted oil reservoir, New Mexico, USA

    Energy Technology Data Exchange (ETDEWEB)

    Wells, A.W.; Diehl, J.R.; Bromhal, G.S.; Strazisar, B.R.; Wilson, T.H. (West Virginia University, Morgantown, WV); White, C.M. (Parsons Corp., South Park, PA)

    2007-05-01

    Geological sequestration of CO2 in depleted oil reservoirs is a potentially useful strategy for greenhouse gas management and can be combined with enhanced oil recovery. Development of methods to estimate CO2 leakage rates is essential to assure that storage objectives are being met at sequestration facilities. Perfluorocarbon tracers (PFTs) were added as three 12 h slugs at about one week intervals during the injection of 2090 tons of CO2 into the West Pearl Queen (WPQ) depleted oil formation, sequestration pilot study site located in SE New Mexico. The CO2 was injected into the Permian Queen Formation. Leakage was monitored in soil–gas using a matrix of 40 capillary adsorbent tubes (CATs) left in the soil for periods ranging from days to months. The tracers, perfluoro-1,2-dimethylcyclohexane (PDCH), perfluorotrimethylcyclohexane (PTCH) and perfluorodimethylcyclobutane (PDCB), were analyzed using thermal desorption, and gas chromatography with electron capture detection. Monitoring was designed to look for immediate leakage, such as at the injection well bore and at nearby wells, and to develop the technology to estimate overall CO2 leak rates based on the use of PFTs. Tracers were detected in soil–gas at the monitoring sites 50 m from the injection well within days of injection. Tracers continued to escape over the following years. Leakage appears to have emanated from the vicinity of the injection well in a radial pattern to about 100 m and in directional patterns to 300 m. Leakage rates were estimated for the 3 tracers from each of the 4 sets of CATs in place following the start of CO2 injection. Leakage was fairly uniform during this period. As a first approximation, the CO2 leak rate was estimated at about 0.0085% of the total CO2 sequestered per annum.

  19. The use of tracers to assess leakage from the sequestration of CO{sub 2} in a depleted oil reservoir, New Mexico, USA

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Arthur W. [National Energy Technology Laboratory, US Department of Energy, P.O. Box 10940, Pittsburgh, PA 15236 (United States); Diehl, J. Rodney [National Energy Technology Laboratory, US Department of Energy, P.O. Box 10940, Pittsburgh, PA 15236 (United States); Bromhal, Grant [National Energy Technology Laboratory, US Department of Energy, P.O. Box 880, Morgantown, WV 26505 (United States); Strazisar, Brian R. [National Energy Technology Laboratory, US Department of Energy, P.O. Box 10940, Pittsburgh, PA 15236 (United States); Wilson, Thomas H. [West Virginia University, Department of Geology and Geography, Morgantown, WV 26506 (United States); White, Curt M. [Parsons Corporation, P.O. Box 618, South Park, PA 15129 (United States)]. E-mail: cwhite@netl.doe.gov

    2007-05-15

    Geological sequestration of CO{sub 2} in depleted oil reservoirs is a potentially useful strategy for greenhouse gas management and can be combined with enhanced oil recovery. Development of methods to estimate CO{sub 2} leakage rates is essential to assure that storage objectives are being met at sequestration facilities. Perfluorocarbon tracers (PFTs) were added as three 12 h slugs at about one week intervals during the injection of 2090 tons of CO{sub 2} into the West Pearl Queen (WPQ) depleted oil formation, sequestration pilot study site located in SE New Mexico. The CO{sub 2} was injected into the Permian Queen Formation. Leakage was monitored in soil-gas using a matrix of 40 capillary adsorbent tubes (CATs) left in the soil for periods ranging from days to months. The tracers, perfluoro-1,2-dimethylcyclohexane (PDCH), perfluorotrimethylcyclohexane (PTCH) and perfluorodimethylcyclobutane (PDCB), were analyzed using thermal desorption, and gas chromatography with electron capture detection. Monitoring was designed to look for immediate leakage, such as at the injection well bore and at nearby wells, and to develop the technology to estimate overall CO{sub 2} leak rates based on the use of PFTs. Tracers were detected in soil-gas at the monitoring sites 50 m from the injection well within days of injection. Tracers continued to escape over the following years. Leakage appears to have emanated from the vicinity of the injection well in a radial pattern to about 100 m and in directional patterns to 300 m. Leakage rates were estimated for the 3 tracers from each of the 4 sets of CATs in place following the start of CO{sub 2} injection. Leakage was fairly uniform during this period. As a first approximation, the CO{sub 2} leak rate was estimated at about 0.0085% of the total CO{sub 2} sequestered per annum.

  20. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Science.gov (United States)

    Zohar, S.; Kissick, D. J.; Venugopalan, N.; Ogata, C. M.; Makarov, O.; Stepanov, S.; Fischetti, R. F.

    2016-09-01

    Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam's susceptibility to higher frequency position oscillations. In this article, we show that a 1 μ m amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  1. Leak testing of bubble-tight dampers using tracer gas techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); DuBois, L.J. [Commonwealth Edison, Zion, IL (United States); Fleming, K.M. [NCS Corporation, Columbus, OH (United States)] [and others

    1995-02-01

    Recently tracer gas techniques have been applied to the problem of measuring the leakage across an installed bubble-tight damper. A significant advantage of using a tracer gas technique is that quantitative leakage data are obtained under actual operating differential pressure conditions. Another advantage is that leakage data can be obtained using relatively simple test setups that utilize inexpensive materials without the need to tear ducts apart, fabricate expensive blank-off plates, and install test connections. Also, a tracer gas technique can be used to provide an accurate field evaluation of the performance of installed bubble-tight dampers on a periodic basis. Actual leakage flowrates were obtained at Zion Generating Station on four installed bubble-tight dampers using a tracer gas technique. Measured leakage rates ranged from 0.01 CFM to 21 CFM. After adjustment and subsequent retesting, the 21 CFM damper leakage was reduced to a leakage of 3.8 CFM. In light of the current regulatory climate and the interest in Control Room Habitability issues, imprecise estimates of critical air boundary leakage rates--such as through bubble-tight dampers--are not acceptable. These imprecise estimates can skew radioactive dose assessments as well as chemical contaminant exposure calculations. Using a tracer gas technique, the actual leakage rate can be determined. This knowledge eliminates a significant source of uncertainty in both radioactive dose and/or chemical exposure assessments.

  2. Magnetic Flux Leakage and Principal Component Analysis for metal loss approximation in a pipeline

    International Nuclear Information System (INIS)

    Ruiz, M; Mujica, L E; Quintero, M; Florez, J; Quintero, S

    2015-01-01

    Safety and reliability of hydrocarbon transportation pipelines represent a critical aspect for the Oil an Gas industry. Pipeline failures caused by corrosion, external agents, among others, can develop leaks or even rupture, which can negatively impact on population, natural environment, infrastructure and economy. It is imperative to have accurate inspection tools traveling through the pipeline to diagnose the integrity. In this way, over the last few years, different techniques under the concept of structural health monitoring (SHM) have continuously been in development.This work is based on a hybrid methodology that combines the Magnetic Flux Leakage (MFL) and Principal Components Analysis (PCA) approaches. The MFL technique induces a magnetic field in the pipeline's walls. The data are recorded by sensors measuring leakage magnetic field in segments with loss of metal, such as cracking, corrosion, among others. The data provide information of a pipeline with 15 years of operation approximately, which transports gas, has a diameter of 20 inches and a total length of 110 km (with several changes in the topography). On the other hand, PCA is a well-known technique that compresses the information and extracts the most relevant information facilitating the detection of damage in several structures. At this point, the goal of this work is to detect and localize critical loss of metal of a pipeline that are currently working. (paper)

  3. Role of natural gas in meeting an electric sector emissions ...

    Science.gov (United States)

    With advances in natural gas extraction technologies, there is an increase in availability of domestic natural gas, and natural gas is gaining a larger share of use as a fuel in electricity production. At the power plant, natural gas is a cleaner burning fuel than coal, but uncertainties exist in the amount of methane leakage occurring upstream in the extraction and production of natural gas. At high leakage levels, these methane emissions could outweigh the benefits of switching from coal to natural gas. This analysis uses the MARKAL linear optimization model to compare the carbon emissions profiles and system-wide global warming potential of the U.S. energy system over a series of model runs in which the power sector is asked to meet a specific CO2 reduction target and the availability of natural gas changes. Scenarios are run with a range of upstream methane emission leakage rates from natural gas production. While the total CO2 emissions are reduced in most scenarios, total greenhouse gas emissions show an increase or no change when both natural gas availability and methane emissions from natural gas production are high. Article presents summary of results from an analyses of natural gas resource availability and power sector emissions reduction strategies under different estimates of methane leakage rates during natural gas extraction and production. This was study was undertaken as part of the Energy Modeling Forum Study #31:

  4. Leakage and Sepage of CO2 from Geologic Carbon SequestrationSites: CO2 Migration into Surface Water

    Energy Technology Data Exchange (ETDEWEB)

    Oldenburg, Curt M.; Lewicki, Jennifer L.

    2005-06-17

    {sub 2} and CH{sub 4} at three different seepage rates reveals that ebullition and bubble flow will be the dominant form of gas transport in surface water for all but the smallest seepage fluxes or shallowest water bodies. The solubility of the gas species in water plays a fundamental role in whether ebullition occurs. We used a solubility model to examine CO{sub 2} solubility in waters with varying salinity as a function of depth below a 200 m-deep surface water body. In this system, liquid CO{sub 2} is stable between the deep regions where supercritical CO{sub 2} is stable and the shallow regions where gaseous CO{sub 2} is stable. The transition from liquid to gaseous CO{sub 2} is associated with a large change in density, with corresponding large change in bubble buoyancy. The solubility of CO{sub 2} is lower in high-salinity waters such as might be encountered in the deep subsurface. Therefore, as CO{sub 2} migrates upward through the deep subsurface, it will likely encounter less saline water with increasing capacity to dissolve CO{sub 2} potentially preventing ebullition, depending on the CO{sub 2} leakage flux. However, as CO{sub 2} continues to move upward through shallower depths, CO{sub 2} solubility in water decreases strongly leading to greater likelihood of ebullition and bubble flow in surface water. In the case of deep density-stratified lakes in which ebullition is suppressed, enhanced mixing and man-made degassing schemes can alleviate the buildup of CO{sub 2} and related risk of dangerous rapid discharges. Future research efforts are needed to increase understanding of CO{sub 2} leakage and seepage in surface water and saturated porous media. For example, we recommend experiments and field tests of CO{sub 2} migration in saturated systems to formulate bubble-driven water-displacement models and relative permeability functions that can be used in simulation models.

  5. Border adjustment for European emissions trading: Competitiveness and carbon leakage

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, Onno, E-mail: onno.kuik@ivm.vu.n [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands); Hofkes, Marjan [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands)

    2010-04-15

    Unilateral or sub-global policies to combat climate change are potentially sensitive to free-riding and carbon leakage. One way of dealing with carbon leakage and competitiveness is the imposition of border adjustment measures for competing imports, for example in the form of the obligation to importers of goods to purchase and surrender emissions allowances to the authorities when importing. In this paper, we explore some implications of border adjustment measures in the EU ETS, for sectors that might be subject to carbon leakage. We examine the implications of two variants of these measures on the competitiveness of these sectors and on the global environment with the help of a multi-sector, multi-region computable general equilibrium (CGE) model of the global economy. Our calculations suggest that border adjustment might reduce the sectoral rate of leakage of the iron and steel industry rather forcefully, but that the reduction would be less for the mineral products sector, including cement. The reduction of the overall or macro rate of leakage would be modest. So, from an environmental point of view border tax adjustments would not be a very effective policy measure, but might mainly be justified by considerations of sectoral competitiveness.

  6. Border adjustment for European emissions trading. Competitiveness and carbon leakage

    Energy Technology Data Exchange (ETDEWEB)

    Kuik, Onno; Hofkes, Marjan [Institute for Environmental Studies, VU University Amsterdam, De Boelelaan 1085, 1081 HV Amsterdam (Netherlands)

    2010-04-15

    Unilateral or sub-global policies to combat climate change are potentially sensitive to free-riding and carbon leakage. One way of dealing with carbon leakage and competitiveness is the imposition of border adjustment measures for competing imports, for example in the form of the obligation to importers of goods to purchase and surrender emissions allowances to the authorities when importing. In this paper, we explore some implications of border adjustment measures in the EU ETS, for sectors that might be subject to carbon leakage. We examine the implications of two variants of these measures on the competitiveness of these sectors and on the global environment with the help of a multi-sector, multi-region computable general equilibrium (CGE) model of the global economy. Our calculations suggest that border adjustment might reduce the sectoral rate of leakage of the iron and steel industry rather forcefully, but that the reduction would be less for the mineral products sector, including cement. The reduction of the overall or macro rate of leakage would be modest. So, from an environmental point of view border tax adjustments would not be a very effective policy measure, but might mainly be justified by considerations of sectoral competitiveness. (author)

  7. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  8. Leakage magnetic field of BLDCM based on Comsol multiphysics

    Science.gov (United States)

    Zhang, Xiaojun; Wen, Jiabao; Wang, Wen; Sun, Jinghua

    2017-04-01

    The measurement of geomagnetic field conducted by underwater robot is widely used during cruise, however, it is often influenced by the strong electromagnetic interference of the other large-scale electronic equipment on the robot itself. The leakage magnetic field of high-power brushless DC motor (BLDCM) has been identified as one of the main interference source. To obtain accurate geomagnetic data, it is necessary to analyze the magnetic field characteristics of the leakage field of BLDCM. In this paper, we build a two-dimensional BLDCM model. In addition, we present the rotor's leakage magnetic field when the BLDCM is static, dynamic leakage magnetic field of the stator and rotor when BLDCM is working and the near-field characteristic of BLDCM's leakage magnetic field. Finally, this paper studies the relationship between the frequency of the magnetic field change and the speed of the BLDCM, which can be used to eliminate the AC interference magnetic field. Therefore the measuring accuracy of the geomagnetic field can be improved.

  9. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  10. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  11. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  12. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  13. Low dark leakage current in organic planar heterojunction photodiodes

    Science.gov (United States)

    Shekhar, Himanshu; Solomeshch, Olga; Liraz, Dan; Tessler, Nir

    2017-11-01

    It is often suggested that the dark leakage current of organic photodiodes is due to extrinsic leakage paths that do not involve the electronic junction. By studying a series of devices, where the acceptor is kept constant (C70) and the donor material is varied, we find a direct correlation between the strength of the sub-gap signature of the charge-transfer states and the leakage current. Attributing the differences in the sub-gap absorption to the donor's sub-gap states suggests that the donor's side of the junction should be made longer, to push the Fermi level at V = 0 towards the acceptor's LUMO, and thus, an optimized value of 800 Pacm-2 at V = -1 V is reported.

  14. Instrumentation with real-world considerations for integrated leakage testing

    International Nuclear Information System (INIS)

    Gibson, L.D.; Carp, J.

    1982-01-01

    In measuring leakage of containment structures, the precise determination of pressure, temperature, dewpoint and flow rate parameters is of critical importance. The change in these values over a specified test period provides the basis for computation of the leakage for a given pressurized volume. The performance of an Integrated Leak Rate Test (ILRT) on the containment is generally a critical path event that must be planned far in advance. The very nature of the test requires rapid, efficient acquisition and processing of data for determination, and sometimes correction, of leakages. Equipment selection is an important consideration which can directly affect the outcome of the test. The intent of this paper is to shed some light on the concerns of choosing an instrumentation package for the ILRT

  15. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  16. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  17. Identification of sources and causes of leakage on a zoned earth dam in northern Taiwan: Hydrological and isotopic evidence

    International Nuclear Information System (INIS)

    Peng, T.-R.; Wang, C.-H.

    2008-01-01

    Seepage through an earth dam body must be regulated as a well-planned process, if it is not properly managed, the abnormal seepage may cause dam failure. This study employed stable isotopic and statistical methods to identify the source and cause of an abnormal leakage on the zoned earth dam of the Xin-Shan reservoir located in northern Taiwan. Water samples from the dam area over a 2-a period were collected and analyzed for their stable O and H isotope compositions. In addition, a 4-a period of hydrological data, including rainfall, reservoir level, well level, seepage of filter drainage and leakage, were statistically analyzed with a stepwise multiple regression approach. Both the stable isotopic and hydrological results indicate that the abnormal leakage on the dam shell comes from the filter drainage in the dam. The reason for abnormal leakage is due to unexpected and significant precipitation-sourced water flowing into the dam's body. The dam filter fails to drain out the incoming water sufficiently, thus generating the abnormal seepage. In addition, the defect in the dam filter may also cause the drainage filter to drain off reservoir seepage inadequately. Therefore, it is suggested that checking the filter function and preventing excessive precipitation-sourced water from flowing into the dam are the two top priorities for the follow-up remedial strategy of the dam

  18. Tracheal fluid leakage in benchtop trials: comparison of static versus dynamic ventilation model with and without lubrication.

    Science.gov (United States)

    Dave, Mital H; Koepfer, Nelly; Madjdpour, Caveh; Frotzler, Angela; Weiss, Markus

    2010-04-01

    Longitudinal folds in tracheal tube (TT) cuffs cause leakage of pooled secretions past the tube cuff, and the most common in vitro method to test the efficacy of a new tube is a benchtop model using an artificial rigid trachea. This study compared the potential of a static and dynamic ventilation benchtop model and cuff lubrication in testing the tracheal sealing properties of a given TT cuff. Static trial Six brands of 7.5 mm internal diameter (ID) cuffed TT (n = 8) with high volume-low pressure cuffs were inflated in an artificial trachea (18 mm ID) without and with lubrication. Dynamic trial The same tube cuffs, without lubrication, were subjected to positive pressure ventilation (PPV) + positive end-expiratory pressure (PEEP) of 5cmH(2)O or to PPV alone (without PEEP) or to PEEP alone (without PPV). Clear water (5 ml) was placed above the tube cuff, and fluid leakage (ml) was measured up to 60 min. Gel lubrication, PEEP alone and PPV + PEEP completely prevented fluid leakage across the tube cuffs in all six TT brands tested within 60 min when compared to the static unlubricated model (0% leak versus 100% leak; P lubrication, PEEP alone, and PPV + PEEP in the benchtop model had a much stronger protective effect than PPV alone on fluid leakage. Studies testing the fluid sealing efficiency of tube cuffs might be more conclusive in a static benchtop model without lubrication than in a dynamic model.

  19. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...... with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  20. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...... with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  1. Investigation of Flyback Transformer Flux Leakage Reduction Ways

    Directory of Open Access Journals (Sweden)

    Edvardas Bielskis

    2017-07-01

    Full Text Available Results of experimental investigation and design optimization of flyback transformer are presented. Aim of the work is to investigate experimentally the impact of the flyback transformer design on the flux leakage and maximal output power. It is difficult to evaluate the effect of the leakage flux mathematically because it depends on various factors: the position of the windings relative to each other; the position of the windings in the transformer; the distance between the winding. A multi-winding flyback transformer was used for experiments. Using the results of the experiments optimal design of the investigated flyback transformer was defined.

  2. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  3. Investigation of the radiation leakage from X ray flaw detectors and the improvement measures for the unqualified products

    International Nuclear Information System (INIS)

    Li Yiachun; Wu Yi; Pang Hu; Bai Bin

    1997-01-01

    The authors introduce investigation methods and results for radiation leakage from X ray flaw detectors, which are used in Beijing area. Total 21 sets of flaw detectors made in 8 factories in Beijing, Shanghai etc. have been tested, of which 16 sets made in Beijing, Dandong and Japan are gas cooling flaw detectors, and rest 5 sets made in Shanghai and Germany are water or oil cooling detectors. The air Kerma rate of leakage radiation at 1 m from the X ray tube target were measured by Type FJ-347A X, γ dosimeter. It can be seen from the results that, compared with the trade standard ZBY315-83, 5 sets of water or oil cooling flaw detectors are all qualified. However, only two sets of gas cooling detectors are qualified, and the radiation leakage of another 14 sets are over the values specified in the standard. The reason is analyzed, and some advices about the measures of improving radiation protection structure design and production technology for the unqualified products have been proposed

  4. Medical evacuations in the oil and gas industry: a retrospective review with implications for future evacuation and preventative strategies.

    Science.gov (United States)

    Toner, Sharyn; Andrée Wiltens, Derkje H; Berg, Johannes; Williams, Hector; Klein, Susan; Marshall, Simon; Nerwich, Neil; Copeland, Ryan

    2017-05-01

    Businesses increasingly conduct operations in remote areas where medical evacuation [Medevac(s)] carries more risk. Royal Dutch Shell developed a remote healthcare strategy whereby enhanced remote healthcare is made available to the patient through use of telemedicine and telemetry. To evaluate that strategy, a review of Medevacs of Shell International employees [i.e. expatriate employees (EEs) and frequent business travellers (FBTs)] was undertaken. A retrospective review of Medevac data (period 2008-12) that were similar in operational constraints and population profile was conducted. Employee records and Human Resource data were used as a denominator for the population. Analogous Medevac data from specific locations were used to compare patterns of diagnoses. A total of 130 Medevacs were conducted during the study period, resulting in a Medevac rate of 4 per 1000 of population with 16 per 1000 for females and 3 per 1000 for males, respectively. The youngest and oldest age-groups required Medevacs in larger proportions. The evacuation rates were highest for countries classified as 'high' or 'extreme risk'. The most frequent diagnostic categories for Medevac were: trauma, digestive, musculoskeletal, cardiac and neurological. In 9% of the total, a strong to moderate link could be made between the pre-existing medical condition and diagnosis leading to Medevac. This study uniquely provides a benchmark Medevac rate (4 per 1000) for EEs and FBTs and demonstrates that Medevac rates are highest from countries identified as 'high risk'; there is an age and gender bias, and pre-existing medical conditions are of notable relevance. It confirms a change in the trend from injury to illness as a reason for Medevac in the oil and gas industry and demonstrates that diagnoses of a digestive and traumatic nature are the most frequent. A holistic approach to health (as opposed to a predominant focus on fitness to work), more attention to female travellers, and the application of

  5. Intermediate-Scale Experimental and Numerical Study of Multiphase CO2 Attenuation in Layered Shallow Aquifers During Leakage from Geologic Sequestration Site

    Science.gov (United States)

    Plampin, M. R.; Pawar, R.; Porter, M. L.; Illangasekare, T. H.

    2015-12-01

    In order to effectively predict and mitigate the potential risks from leakage of stored CO2, we must first understand the physicochemical processes that CO2 undergoes during migration through shallow aquifers, including dissolved phase advection and dispersion as well as gas phase exsolution, multiphase flow, and dissolution. Since field sites are inherently large-scale, heterogeneous, 3-D systems, large-scale experimental data is important to validate numerical models and to make confident predictions regarding CO2 migration. A large, highly instrumented, two-dimensional tank was built and packed with porous media to represent a portion of a layered shallow aquifer. Flow of water across the tank was established by applying a small difference in head between the two ends. A separate stream of water was then saturated with dissolved CO2 and injected into the bottom of the tank near the upstream end. Various saturation sensors measured the spatiotemporal pattern of gas phase evolution in the tank, while an external sensor and an Ion Chromatograph were used to monitor the dissolved CO2 concentrations at various locations in the system. The top of the tank was baffled into four sealed compartments, each of which was connected to a gas flow meter to monitor the spatiotemporal pattern of gas phase CO2 release to the atmosphere. Numerical simulations were also performed to better understand the fundamental physics that drove the observed CO2 evolution processes, and to help validate a widely used code using the experimental data. The simulations were performed with the Finite Element Heat and Mass Transfer (FEHM) software that was developed at Los Alamos National Laboratory. The model domain, porous media properties, and initial conditions were set up to match those of the experiment, and the boundary conditions were adjusted to investigate the mass transfer between the dissolved and gaseous phases of CO2 that developed within the system. Results from both the experiments

  6. University student's education after Fukushima nuclear leakage crisis

    International Nuclear Information System (INIS)

    Dou Daying; Gu Jianzhong; Zheng Jianying

    2012-01-01

    Fukushima nuclear leakage crisis after 3.11 earthquake and tsunami, the horrible INES-7 accident warns the colleagues all over the world. Own much to the experts' reports on public media, INES classification, basic knowledge of nuclear reactor, nuclear safety and protection had been discussed and brain-stormed in detail. (authors)

  7. Signature Schemes Secure against Hard-to-Invert Leakage

    DEFF Research Database (Denmark)

    Faust, Sebastian; Hazay, Carmit; Nielsen, Jesper Buus

    2012-01-01

    In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information-theoretically re......In the auxiliary input model an adversary is allowed to see a computationally hard-to-invert function of the secret key. The auxiliary input model weakens the bounded leakage assumption commonly made in leakage resilient cryptography as the hard-to-invert function may information......-theoretically reveal the entire secret key. In this work, we propose the first constructions of digital signature schemes that are secure in the auxiliary input model. Our main contribution is a digital signature scheme that is secure against chosen message attacks when given an exponentially hard-to-invert function...... of the secret key. As a second contribution, we construct a signature scheme that achieves security for random messages assuming that the adversary is given a polynomial-time hard to invert function. Here, polynomial-hardness is required even when given the entire public-key – so called weak auxiliary input...

  8. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  9. Detection of tissue expander leakage by methylene blue instillation ...

    African Journals Online (AJOL)

    Background: Tissue expansion is an important and widely used technique of soft tissue reconstruction. Leakage of the expanders is one of the complications and it might at times be difficult to detect. Method and Conclusion: We used methylene blue stained saline for inflation of tissue expanders in 42 cases and found it to ...

  10. Incidence and management of biliary leakage after hepaticojejunostomy

    NARCIS (Netherlands)

    de Castro, Steve M. M.; Kuhlmann, Koert F. D.; Busch, Olivier R. C.; van Delden, Otto M.; Laméris, Johan S.; van Gulik, Thomas M.; Obertop, Hugo; Gouma, Dirk J.

    2005-01-01

    This study analyzes the change in the management of biliary leakage after hepaticojejunostomy. Between 1993 and 2003 all patients (n = 1033) were studied with a hepaticojejunostomv as part of a pancreatoduodenectomy (n = 486), proximal bile duct resection (without liver resection) (n = 35), and

  11. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    model, most of them are unfortunately rather inefficient and come without practical security evaluations nor implementation attempts. In this work, we take a further step towards closing the gap between theoretical leakage resilient cryptography and more practice-oriented research. In particular, we...

  12. Impact of the Indonesian throughflow on Agulhas leakage

    NARCIS (Netherlands)

    le Bars, D.L.B.|info:eu-repo/dai/nl/326165150; Dijkstra, H.A.|info:eu-repo/dai/nl/073504467; de Ruijter, W.P.M.|info:eu-repo/dai/nl/068476760

    2013-01-01

    Using ocean models of different complexity we show that opening the Indonesian Passage between the Pacific and the Indian Ocean increases the input of Indian Ocean water into the South Atlantic via the Agulhas leakage. In a strongly eddying global 5 ocean model this response results from an

  13. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  14. Interslice leakage artifact reduction technique for simultaneous multislice acquisitions.

    Science.gov (United States)

    Cauley, Stephen F; Polimeni, Jonathan R; Bhat, Himanshu; Wald, Lawrence L; Setsompop, Kawin

    2014-07-01

    Controlled aliasing techniques for simultaneously acquired echo-planar imaging slices have been shown to significantly increase the temporal efficiency for both diffusion-weighted imaging and functional magnetic resonance imaging studies. The "slice-GRAPPA" (SG) method has been widely used to reconstruct such data. We investigate robust optimization techniques for SG to ensure image reconstruction accuracy through a reduction of leakage artifacts. Split SG is proposed as an alternative kernel optimization method. The performance of Split SG is compared to standard SG using data collected on a spherical phantom and in vivo on two subjects at 3 T. Slice-accelerated and nonaccelerated data were collected for a spin-echo diffusion-weighted acquisition. Signal leakage metrics and time-series SNR were used to quantify the performance of the kernel fitting approaches. The Split SG optimization strategy significantly reduces leakage artifacts for both phantom and in vivo acquisitions. In addition, a significant boost in time-series SNR for in vivo diffusion-weighted acquisitions with in-plane 2× and slice 3× accelerations was observed with the Split SG approach. By minimizing the influence of leakage artifacts during the training of SG kernels, we have significantly improved reconstruction accuracy. Our robust kernel fitting strategy should enable better reconstruction accuracy and higher slice-acceleration across many applications. Copyright © 2013 Wiley Periodicals, Inc.

  15. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.|info:eu-repo/dai/nl/357401387; van Noort, Reinier|info:eu-repo/dai/nl/304833460; Spiers, Christopher J.|info:eu-repo/dai/nl/304829323

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  16. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    driniev

    5 (Special edition). 25. Available on website http://www.wrc.org.za. Benchmarking leakage from water reticulation systems in. South Africa. Caryn Seago1*, Jay Bhagwan2 and Ronnie McKenzie1. 1WRP Consulting ... limited and that careful management should be applied when ..... purchase price (or product price) of water.

  17. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  18. Characterization of CO2 leakage into the freshwater body

    DEFF Research Database (Denmark)

    Singh, Ashok; Delfs, Jens Olaf; Shao, H.

    2013-01-01

    , the leakage into a multi-layered fractured saline aquifer is modelled with a numerical model regarding its pressure build-up process. The investigation is performed with the non-isothermal compositional fluid flow module implemented by authors in the OpenGeoSys (OGS) software for geotechnical applications....

  19. Incidence and management of bile leakage after partial liver resection

    NARCIS (Netherlands)

    Erdogan, D.; Busch, O. R. C.; van Delden, O. M.; Rauws, E. A. J.; Gouma, D. J.; van Gulik, T. M.

    2008-01-01

    Background/Aims: Bile leakage after partial liver resection still is a common complication and is associated with substantial morbidity and even mortality. Methods: A total of 234 consecutive liver resections without biliary reconstruction, performed between January 1992 and December 2004, were

  20. Carbon Leakage Revisited : Unilateral Climate Policy with Directed Technical Change

    NARCIS (Netherlands)

    Di Maria, C.; van der Werf, E.H.

    2005-01-01

    The increase in carbondioxide emissions by some countries in reaction to an emission reduction by countries with climate policy (carbon leakage) is seen as a serious threat to unilateral climate policy.Using a two-country model where only one of the countries enforces an exogenous cap on emissions,

  1. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    A project to assess the levels of leakage in 30 water utilities throughout South Africa was initiated by the Water Research Commission. The BENCHLEAK software was used to evaluate the water utilities and performance indicators calculated by the model were used to compare levels of non-revenue water. Results showed ...

  2. Effect of Surface Treatments on Leakage of Zirconium Oxide Ceramics

    Directory of Open Access Journals (Sweden)

    Göknil Alkan Demetoğlu

    2016-08-01

    Full Text Available Objective: The aim of this pilot study was to compare the effects of pretreatments on leakage of zirconia ceramics. Materials and Methods: The speciments divided into 6 groups that were subsequently treated as follows: group 1, no treatment (control; group 2, the ceramic surfaces were airborne-particle abraded with 110 μm aluminum-oxide (Al2O3 particles; group 3, after abrasion of the surfaces with 110 μm Al2O3 particles, silica coating using 30 μm (Al2O3 particles modified by silica (rocatec system and application of the silane coupling agent (espe-sil; group 4, ceramic surfaces irritated with neodymium-doped yttrium aluminium garnet (Nd:YAG laser [fidelis plus 3 foton (Ljubljana, Slovenia] at 20 hz, 100 mj, 2 w, 100 μs; group 5, ceramic surfaces irritated with Nd:YAG laser at fidelis plus 3 fotona (Ljubljana, Slovenia at 20 hz, 100 mj, 2 w, 100 μs; group 6; application of a zirconia primer (z-prime plus bisco, IL, USA agent. And all ceramics tested for leakage. Results: For marginal leakage, score 0 was found in all groups. Conclusion: No significant differences were found in marginal leakage under all conditions.

  3. Isoflurane leakage from non-rebreathing rodent anaesthesia circuits: comparison of emissions from conventional and modified ports.

    Science.gov (United States)

    Smith, J C; Bolon, B

    2006-04-01

    Chronic exposure to low levels of fluorocarbon-based waste anaesthetic gas (WAG) has been linked to a multitude of human health problems. We have shown that isoflurane exhaust from passive gas-scavenging canisters is often quite high when using conventional rodent anaesthesia protocols and equipment. Another likely source of WAG build-up in rodent procedure rooms is leakage at the interface between the breathing circuit and the animal's face. We evaluated this possibility using three non-rebreathing circuits: traditional Bain, modified Bain, and Mapleson (type E). For the Mapleson E circuit, a conical rodent facemask was attached and used in one of two configurations: normal aperture, or aperture modified with a latex diaphragm (cut from an unpowdered surgical glove) to reduce the orifice diameter and tighten the seal. Adult female Sprague-Dawley rats were anaesthetized with isoflurane (5% for induction, 2% or 3.5% for maintenance) in oxygen (2 L/min for induction, 1 L/min for maintenance). Isoflurane leakage was assessed by real-time spectrophotometry. In 94% of the trials, three configurations - traditional Bain, modified Bain, and Mapleson E with unmodified mask - permitted isoflurane leakage approaching or exceeding 100 ppm at the face/port interface. In contrast, the Mapleson circuit with diaphragm-modified mask emitted significantly (Pleakage from standard rodent non-rebreathing circuits is substantial, and that (2) a simple, rapid, and economical modification to a conventional rodent facemask can significantly reduce WAG exposure to workers performing many rodent anaesthesia procedures in one session.

  4. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  5. New Leakage Current Particulate Matter Sensor for On-Board Diagnostics

    Directory of Open Access Journals (Sweden)

    Jiawei Wang

    2016-01-01

    Full Text Available Structure and principle of the new leakage current particulate matter (PM sensor are introduced and further study is performed on the PM sensor with the combination of numerical simulation and bench test. High voltage electrode, conductive shell, and heaters are all built-in. Based on the principle of Venturi tube and maze structure design, this sensor can detect transient PM concentrations. Internal flow field of the sensor and distribution condition of PM inside the sensor are analyzed through gas-solid two-phase flow numerical simulation. The experiment was also carried out on the whole sensor system (including mechanical and electronic circuit part and the output signals were analyzed. The results of simulation and experiment reveal the possibility of PM concentration (mass detection by the sensor.

  6. Postoperative non-steroidal anti-inflammatory drugs and colorectal anastomotic leakage. NSAIDs and anastomotic leakage.

    Science.gov (United States)

    Klein, Mads

    2012-03-01

    Anastomotic leakage (AL) is the most important and one of the most serious complications after colorectal resections with primary anastomosis. Any factors that contribute to increase the risk of AL should be identified and--if possible--eliminated. Non-steroidal anti-inflammatory drugs (NSAIDs) are often used for treating pain after surgical procedures, among these also colorectal resections. The objective of this Ph.d. thesis was to investigate whether the use of NSAIDs in the postoperative period increases the risk of AL, and investigate the effect on pathophysiological mechanisms. In order to achieve this, the following studies were performed. Study I was a retrospective, case-control study in 75 patients undergoing laparoscopic colorectal resection for colorectal cancer. 33 of these patients received the NSAID diclofenac in the postoperative period; the remaining 42 did not receive any NSAID. There were significantly more ALs among the patients receiving diclofenac (7/33 vs. 1/42, p=0.018). In uni- and multivariate logistic regression analyses, diclofenac was the only factor associated with increased AL rate. This study functioned as a hypothesis generating study and laid the ground for the subsequent studies. Study II was an experimental, randomized, case-control study in 32 Wistar rats. The rats had a colonic anastomosis performed and were randomized to diclofenac or placebo treatment. After three days, the rats were sacrificed and the anastomoses were harvested. First, the anastomotic strengths were tested by longitudinal; subsequently, the levels of the enzyme cyclooxygenase-2 (COX-2) in the anastomotic tissues were measured. There was no difference among the groups with regard to anastomotic strength, but the animals treated with diclofenac had significantly lower COX-2 levels (median (range) 1.30 (0.42-3.31) ng/mg vs. 2.44 (0.88 - 18.94) ng/mg, pNSAID treatment. Study III was also an experimental, randomized, case-control study. This time round, 60 Wistar

  7. Risk analysis of urban gas pipeline network based on improved bow-tie model

    Science.gov (United States)

    Hao, M. J.; You, Q. J.; Yue, Z.

    2017-11-01

    Gas pipeline network is a major hazard source in urban areas. In the event of an accident, there could be grave consequences. In order to understand more clearly the causes and consequences of gas pipeline network accidents, and to develop prevention and mitigation measures, the author puts forward the application of improved bow-tie model to analyze risks of urban gas pipeline network. The improved bow-tie model analyzes accident causes from four aspects: human, materials, environment and management; it also analyzes the consequences from four aspects: casualty, property loss, environment and society. Then it quantifies the causes and consequences. Risk identification, risk analysis, risk assessment, risk control, and risk management will be clearly shown in the model figures. Then it can suggest prevention and mitigation measures accordingly to help reduce accident rate of gas pipeline network. The results show that the whole process of an accident can be visually investigated using the bow-tie model. It can also provide reasons for and predict consequences of an unfortunate event. It is of great significance in order to analyze leakage failure of gas pipeline network.

  8. Bacterial leakage in roots filled with different medicaments and sealed with Cavit.

    Science.gov (United States)

    Barthel, Claudia R; Zaritzki, Felix F; Raab, Wolfgang H-M; Zimmer, Stefan

    2006-02-01

    The aim of this study was to evaluate the time required by four different root canal medications coupled with the temporary filling material Cavit (ESPE, Seefeld, Germany) to prevent penetration of bacteria into the root canal. There were 145 roots prepared in a standardized manner. Four groups with 15 samples each were dressed with calcium hydroxide (Ca(OH)(2)), a 5% chlorhexidine gel (CHX), a chloromono-campherphenolic compound (ChKM), and Ledermix (LM), respectively, and sealed with Cavit. Four control groups contained identical medications but the roots were left unsealed. The 25 remaining roots served as additional controls. A standard setup for bacterial leakage studies was chosen with Staphylococcus epidermidis as test strain. Cavit application resulted in a significantly better seal compared with the unsealed groups. In the Cavit-sealed groups, all groups differed significantly from one another except for the CHX and the ChKM groups. The Ca(OH)(2) medicated roots provided the longest protection (median of 36 days), followed by the Ledermix-group (27 days) and the CHX (18 days) or ChKM groups (19 days). It may be concluded that Cavit-sealed and medicated root canals do not provide adequate protection against bacterial leakage for more than 1 month.

  9. Characterisation, quantification and modelling of CO2 transport and interactions in a carbonate vadose zone: application to a CO2 diffusive leakage in a geological sequestration context

    International Nuclear Information System (INIS)

    Cohen, Gregory

    2013-01-01

    Global warming is related to atmospheric greenhouse gas concentration increase and especially anthropogenic CO 2 emissions. Geologic sequestration has the potential capacity and the longevity to significantly diminish anthropogenic CO 2 emissions. This sequestration in deep geological formation induces leakage risks from the geological reservoir. Several leakage scenarios have been imagined. Since it could continue for a long period, inducing environmental issues and risks for human, the scenario of a diffusive leakage is the most worrying. Thus, monitoring tools and protocols are needed to set up a near-surface monitoring plan. The present thesis deals with this problematic. The aims are the characterisation, the quantification and the modelling of transport and interactions of CO 2 in a carbonate unsaturated zone. This was achieved following an experimental approach on a natural pilot site in Saint-Emilion (Gironde, France), where diffusive gas leakage experiments were set up in a carbonate unsaturated zone. Different aspects were investigated during the study: natural pilot site description and instrumentation; the physical and chemical characterisation of carbonate reservoir heterogeneity; the natural functioning of the carbonate unsaturated zone and especially the set-up of a CO 2 concentrations baseline; the characterisation of gas plume extension following induced diffusive leakage in the carbonate unsaturated zone and the study of gas-water-rock interactions during a CO 2 diffusive leakage in a carbonate unsaturated zone through numerical simulations. The results show the importance of the carbonate reservoir heterogeneity characterisation as well as the sampling and analysing methods for the different phases. The baseline set-up is of main interest since it allows discrimination between the induced and the natural CO 2 concentrations variations. The transfer of CO 2 in a carbonate unsaturated zone is varying in function of physical and chemical properties

  10. Perioperative Statin Therapy Is Not Associated With Reduced Risk of Anastomotic Leakage After Colorectal Resection

    DEFF Research Database (Denmark)

    Bisgård, Anne Sofie; Noack, Morten Westergaard; Klein, Mads

    2013-01-01

    Anastomotic leakage is a serious complication of colorectal surgery. Several studies have demonstrated the beneficial pleiotropic effects of statins, and preliminary studies have suggested that perioperative statin treatment may be associated with reduced risk of anastomotic leakage....

  11. Intraoperative and postoperative risk factors for anastomotic leakage and pneumonia after esophagectomy for cancer

    NARCIS (Netherlands)

    Goense, L.; van Rossum, P. S N; Tromp, M.; Joore, JCA; van Dijk, D.; Kroese, A. C.; Ruurda, J. P.; van Hillegersberg, R.

    Morbidity and mortality after esophagectomy are often related to anastomotic leakage or pneumonia. This study aimed to assess the relationship of intraoperative and postoperative vital parameters with anastomotic leakage and pneumonia after esophagectomy. Consecutive patients who underwent

  12. Hydrochemical Impacts of CO2 Leakage on Fresh Groundwater: a Field Scale Experiment

    Science.gov (United States)

    Lions, J.; Gal, F.; Gombert, P.; Lafortune, S.; Darmoul, Y.; Prevot, F.; Grellier, S.; Squarcioni, P.

    2013-12-01

    samples provide chemical elements (major, minor and trace metals), dissolved gases, microbiological diversity and isotopes (13C). The evolution of the composition of the groundwater in terms of major elements, trace elements and isotope signatures is interpreted in terms of geochemical mechanisms, and the water-rock-CO2 interactions are characterized. Modification of the chemical composition of water in the aquifer due to CO2 injection is assessed in term of groundwater quality i.e. metal element release and the possibility of exceeding references and quality of water for human consumption. One outcome of the CIPRES project will be to highlight mechanisms that can impact groundwater quality when a CO2 leakage occurs and to propose recommendations to prevent or/and eliminate negative effects and any risks to the environment and human health. This project is partially funded by the French Research Agency (ANR).

  13. Gas and Gas Pains

    Science.gov (United States)

    ... to produce gas. Often, relatively simple changes in eating habits can lessen bothersome gas. Certain digestive system disorders, ... such as soda and beer, increase stomach gas. Eating habits, such as eating too quickly, drinking through a ...

  14. Loading and leakage of krypton immobilized in zeolites and glass

    International Nuclear Information System (INIS)

    Christensen, A.B.; Del Debbio, J.A.; Knecht, D.A.; Tanner, J.E.

    1980-01-01

    Krypton-85 is formed in nuclear power reactors and remains trapped until the fuel is reprocessed. Federal regulations limit the release of 85 Kr to the environment, requiring recovery and storage of 85% of the 85 Kr produced in commercial light-water reactors after January 1, 1983. One of the long-term storage options involves encapsulating 85 Kr in zeolites or glasses at high pressure and temperature. This paper presents experimental results for krypton encapsulation and leakage in sodalite, zeolite 5A, and Vycor Thristy glass. The results show that all three materials are feasible for 85 Kr immobilization and long-term storage, although zeolite 5A and Thirsty Vycor are preferable due to lower leakage rates

  15. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... the value of the respective function on the internal state of the respective device (namely, on its secret share, internal randomness, and results of intermediate computations). We present distributed public key encryption (DPKE) and distributed identity based encryption (DIBE) schemes that are secure......-secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol...

  16. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  17. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  18. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P.; Vranka, L. [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1997-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  19. Microbial succession and stimulation following a test well injection simulating CO2 leakage into shallow Newark Basin aquifers

    Science.gov (United States)

    Dueker, M.; Clauson, K.; Yang, Q.; Umemoto, K.; Seltzer, A. M.; Zakharova, N. V.; Matter, J. M.; Stute, M.; Takahashi, T.; Goldberg, D.; O'Mullan, G. D.

    2012-12-01

    Despite growing appreciation for the importance of microbes in altering geochemical reactions in the subsurface, the microbial response to geological carbon sequestration injections and the role of microbes in altering metal mobilization following leakage scenarios in shallow aquifers remain poorly constrained. A Newark Basin test well was utilized in field experiments to investigate patterns of microbial succession following injection of CO2 saturated water into isolated aquifer intervals. Additionally, laboratory mesocosm experiments, including microbially-active and inactive (autoclave sterilized) treatments, were used to constrain the microbial role in mineral dissolution, trace metal release, and gas production (e.g. hydrogen and methane). Hydrogen production was detected in both sterilized and unsterilized laboratory mesocosm treatments, indicating abiotic hydrogen production may occur following CO2 leakage, and methane production was detected in unsterilized, microbially active mesocosms. In field experiments, a decrease in pH following injection of CO2 saturated aquifer water was accompanied by mobilization of trace elements (e.g. Fe and Mn), the production of hydrogen gas, and increased bacterial cell concentrations. 16S ribosomal RNA clone libraries, from samples collected before and after the test well injection, were compared in an attempt to link variability in geochemistry to changes in aquifer microbiology. Significant changes in microbial composition, compared to background conditions, were found following the test well injection, including a decrease in Proteobacteria, and an increased presence of Firmicutes, Verrucomicrobia, Acidobacteria and other microbes associated with iron reducing and syntrophic metabolism. The concurrence of increased microbial cell concentration, and rapid microbial community succession, with increased concentrations of hydrogen gas suggests that abiotically produced hydrogen may serve as an ecologically-relevant energy

  20. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  1. Investigation of carrier mobility degradation effects on MOSFET leakage simulations

    CSIR Research Space (South Africa)

    Twala, B

    2016-01-01

    Full Text Available of electric field, carrier temperature and impact ionization. 4. Several vertical grid spacing inside the gate oxide when simulating gate field effects such as gate induced drain leakage (GIDL) or using any hot electron or tunneling gate current models... on its gain and is proportional to the hole or electron mobility (depending on device type); at least for low drain voltages. The transverse field dependent mobility models are of particular importance for simulating MOS devices. Because the reduction...

  2. Deforestation, Leakage and Avoided Deforestation Policies: A Spatial Analysis

    OpenAIRE

    Philippe Delacote; Elizabeth J. Z. Robinson; Sébastien Roussel

    2015-01-01

    This paper analyses the impact of several avoided deforestation policies within a patchy forested landscape. Central is the idea that one neighbour's deforestation actions may impact the returns to deforestation in nearby patches. We determine the impact of each policy in terms of avoided deforestation and leakage levels at the landscape scale through modelling and simulations. Avoided deforestation policies at a landscape level are respectively: two Payment for Environmental Services (PES) p...

  3. Breakdown of equipartition in diffuse fields caused by energy leakage

    Science.gov (United States)

    Margerin, L.

    2017-05-01

    Equipartition is a central concept in the analysis of random wavefields which stipulates that in an infinite scattering medium all modes and propagation directions become equally probable at long lapse time in the coda. The objective of this work is to examine quantitatively how this conclusion is affected in an open waveguide geometry, with a particular emphasis on seismological applications. To carry our this task, the problem is recast as a spectral analysis of the radiative transfer equation. Using a discrete ordinate approach, the smallest eigenvalue and associated eigenfunction of the transfer equation, which control the asymptotic intensity distribution in the waveguide, are determined numerically with the aid of a shooting algorithm. The inverse of this eigenvalue may be interpreted as the leakage time of the diffuse waves out of the waveguide. The associated eigenfunction provides the depth and angular distribution of the specific intensity. The effect of boundary conditions and scattering anisotropy is investigated in a series of numerical experiments. Two propagation regimes are identified, depending on the ratio H∗ between the thickness of the waveguide and the transport mean path in the layer. The thick layer regime H∗ > 1 has been thoroughly studied in the literature in the framework of diffusion theory and is briefly considered. In the thin layer regime H∗ parallel to the surface and equipartition breaks down. Qualitatively, the anisotropy of the intensity field is found to increase with the inverse non-dimensional leakage time, with the scattering mean free time as time scale. Because it enhances leakage, a rough free surface may result in stronger anisotropy of the intensity field than a flat surface, for the same bulk scattering properties. Our work identifies leakage as a potential explanation for the large deviation from isotropy observed in the coda of body waves.

  4. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  5. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  6. Pore formation by T3SS translocators: liposome leakage assay.

    Science.gov (United States)

    Faudry, Eric; Perdu, Caroline; Attrée, Ina

    2013-01-01

    Gram-negative bacteria utilize a dedicated membrane-embedded apparatus, the type III secretion system (T3SS), to inject proteins into host cells. The passage of the proteins across the target membrane is accomplished by a proteinaceous pore-the translocon-formed within the host-cell cytoplasmic membrane. Translocators bound to their chaperones can be expressed in Escherichia coli and subsequently dissociated from the chaperone by guanidine treatment. The pore formation properties of the translocators can then be studied by an in-vitro liposome leakage assay. Sulforhodamine-B is encapsulated within lipid vesicles during liposome preparation. At high concentration, this fluorochrome exhibits self-quenching limiting fluorescence emission. Upon pore formation, liposome leakage leads to the dilution of Sulforhodamine-B in the medium and fluorescence emission increases. Alternatively, fluorochromes coupled to large dextran molecules can be encapsulated in order to estimate pore dimensions. Here we describe protein expression and purification, dye-liposome preparation, and leakage assay conditions.

  7. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  8. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  9. Mechanistic approach to the sodium leakage and fire analysis

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Muramatsu, Toshiharu; Ohira, Hiroaki; Ida, Masao

    1997-04-01

    In December 1995, a thermocouple well was broken and liquid sodium leaked out of the intermediate heat transport system of the prototype fast breeder reactor Monju. In the initiating process of the incident, liquid sodium flowed out through the hollow thermocouple well, nipple and connector. As a result, liquid sodium, following ignition and combustion, was dropping from the connector to colide with the duct and grating placed below. The collision may cause fragmentation and scattering of the sodium droplet that finally was piled up on the floor. This report deals with the development of computer programs for the phenomena based on mechanistics approach. Numerical analyses are also made for fundamental sodium leakage and combustion phenomenon, sodium combustion experiment, and Monju incident condition. The contents of this report is listed below: (1) Analysis of chemical reaction process based on molecular orbital method, (2) Thermalhy draulic analysis of the sodium combustion experiment II performed in 1996 at O-arai Engineering Center, PNC, (3) Thermalhy draulic analysis of room A-446 of Monju reactor when the sodium leakage took place, (4) Direct numerical simulation of sodium droplet, (5) Sodium leakage and scattering analysis using three dimensional particle method, (6) Multi-dimensional combustion analysis and multi-point approximation combustion analysis code. Subsequent to the development work of the programs, they are to be applied to the safety analysis of the Fast Breeder Reactor. (author)

  10. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, S.; Kissick, D. J.; Venugopalan, N.; Ogata, C. M.; Makarov, O.; Stepanov, S.; Fischetti, R. F.

    2016-09-01

    Small X-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation X-ray beamlines is the slow detuning of X-ray optics to marginal alignment where the onset of clipping increases the beam’s susceptibility to higher frequency position oscillations. In this article, we show that a 1 µm amplitude horizontal X-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  11. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, S.; Kissick, D. J.; Venugopalan, N.; Ogata, C. M.; Makarov, O.; Stepanov, S.; Fischetti, R. F.

    2016-09-01

    Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam's susceptibility to higher frequency position oscillations. In this article, we show that a 1 mu m amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  12. Extremum seeking x-ray position feedback using power line harmonic leakage as the perturbation

    Directory of Open Access Journals (Sweden)

    S. Zohar

    2016-09-01

    Full Text Available Small x-ray beam sizes necessary for probing nanoscale phenomena require exquisite stability to prevent data corruption by noise. One source of instability at synchrotron radiation x-ray beamlines is the slow detuning of x-ray optics to marginal alignment where the onset of clipping increases the beam’s susceptibility to higher frequency position oscillations. In this article, we show that a 1  μm amplitude horizontal x-ray beam oscillation driven by power line harmonic leakage into the electron storage ring can be used as perturbation for horizontal position extremum seeking feedback. Feedback performance is characterized by convergence to 1.5% away from maximum intensity at optimal alignment.

  13. Evaluation of Winter Hardiness in Peppermint (Mentha piperita L. by Electrolyte Leakage Indicator

    Directory of Open Access Journals (Sweden)

    A. Nezami

    2016-10-01

    laboratory. The initial temperature of programmable freezer was 5°C; but gradually decreased in a rate of 2°C.h-1 until reached to desired temperatures. When the temperature reached to -2°C, the plants were sprayed with the Ice Nucleation Active Bacteria (INAB to help the formation of ice nuclei in them. As well the spraying had been conducted to prevent from super-cooling of samples and to ensure that the mechanism of freeze resistance is tolerance not avoidance. After a desired freezing temperature was reached, the samples were removed from the freezer and then were thawed slowly during 24 h in a refrigerator at 5±1°C. In order to assess plasma membrane stability, four freeze stressed samples from stolon and rhizome were incubated in vials which containing 50 ml of double distilled water and the initial electrolyte leakage (E1 was measured by an electrical conductivity meter next day. Afterward for determining of final electrolyte leakage due to the death of whole sample, accessions were boiled in autoclave with pressure near to 1.2 bar and temperature around 110°C for 20 minutes. E2 was measured next day similar to E1. Electrolyte leakage percentage was expressed as E1 to E2 ratio. Afterward lethal temperature for 50% of samples according to the EL% (LT50el was calculated to estimate the freeze tolerance of peppermint organs during different sampling times. Results and discussion : Results showed that by decreasing of temperatures, EL% increased in both organs and at -20°C, EL% was 50 percent more than control (0°C treatment. Moreover at -12°C, EL% from stolons was eight % less than rhizomes. Studies showed that cold sensitive plants or organs showed further amount of ions leakage from their cells. So further leaked material from rhizomes should be interpreted as more sensitivity of this organ to freezing temperatures in comparison to stolon. The least and the most EL% was observed in January and April, respectively. And the least and the most value of LT50el was

  14. Gas distribution equipment in hydrogen service - Phase II

    Science.gov (United States)

    Jasionowski, W. J.; Huang, H. D.

    1980-01-01

    The hydrogen permeability of three different types of commercially available natural gas polyethylene pipes was determined. Ring tensile tests were conducted on permeability-exposed and as-received samples. Hydrogen-methane leakage experiments were also performed. The results show no selective leakage of hydrogen via Poiseuille, turbulent, or orifice flow (through leaks) on the distribution of blends of hydrogen and methane. The data collected show that the polyethylene pipe is 4 to 6 times more permeable to hydrogen than to methane.

  15. Comparison of preparation design and material thickness on microbial leakage through Cavit using a tooth model system.

    Science.gov (United States)

    Weston, Charles H; Barfield, Robert D; Ruby, John D; Litaker, Mark S; McNeal, Sandre F; Eleazer, Paul D

    2008-04-01

    Few studies have compared Cavit thickness and access design as factors in microbial leakage. The present study used an acrylic tooth model to measure leakage of Streptococcus mutans. Pilot studies confirming the sterility of Cavit showed it will inhibit microbial growth for 2 days. The experiments compared class I preparations where Cavit thickness was 4 mm with class II preparations where thickness was 2-3 mm. Accesses sealed with cotton pellets were compared with those without cotton. Results of the study showed no bacterial contamination in any of the class I samples (up to 14 days). Some class II samples showed contamination at day 1 (3 out of 14), with all contaminated at day 7 (14 of 14), yet only 1 contaminated at day 14 (1 out of 14). The results suggest that a 4-mm thickness of Cavit should prevent bacterial ingress for at least 2 weeks, but microbial leakage may occur if temporary thickness is less than 3 mm or in a complex access preparation.

  16. A novel SnO(2)-based gas sensor.

    Science.gov (United States)

    Siroký, K; Jiresová, J

    1994-10-01

    A novel 'two-terminal' semiconductor gas sensor was developed based on a heavily Sb-doped SnO(2) film prepared by cathodic sputtering. The sensor is heated at its operational temperature by the gas sensitive film itself. A device for detecting the leakage of flammable gases, some noxious or hazardous gases can be made in this way.

  17. IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE

    International Nuclear Information System (INIS)

    Andrews, J.W.

    2002-01-01

    The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases

  18. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    Science.gov (United States)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  19. Carbon Leakage in the Primary Aluminium Sector: What evidence after 6 1/2 years of the EU ETS? - Working Paper No. 2012-12

    International Nuclear Information System (INIS)

    Sartor, Oliver

    2012-02-01

    This paper provides an econometric analysis of the evidence of carbon leakage from the European primary aluminium industry during the first 6 1/2 years of the EU ETS. The findings suggest that while rising electricity prices have played a critical role in reducing the competitiveness of EU primary aluminium smelting in recent years, no evidence of carbon leakage can be detected so far. Other factors, including rising primary energy prices and changes in EU competition law regarding long term contracts, appear to be more important factors explaining the rise in net imports of primary aluminium and the gradual closure of a number of European primary smelters during the past 6 1/2 years. Our results suggest that the carbon leakage debate in this sector may therefore be better seen in terms of not accelerating the decline of the industry in Europe, rather than preventing it, and that any state-aid to the industry to prevent carbon leakage should therefore be applied accordingly. (author)

  20. Assuring asset integrity through improving the accuracy of leakage source identification of a permanently installed subsea leak detection system using artificial neural networks

    OpenAIRE

    Poungkrajorn, Tawan

    2015-01-01

    Master's thesis in Offshore technology : industrial asset management Environmental concerns and regulatory controls for oil and gas exploration and production activities have been increasing with the prospecting of deep-water fields and sensitive areas, such as the artic seas. To stop any incidents developing into critical events, subsea leak detection systems are required for a fast, cost-effective, and reasonable accurate method to not only detect the leakage substance (in this case meth...

  1. Random survey of HFC and R22 emission, refrigerants and leakage percentage in the dairy, meat and other food industries; Steekproefonderzoek HFK en R22-emissies, koudemiddelvulling en lekpercentage in de Zuivel, Vlees en Overige voedingsmiddelensectoren

    Energy Technology Data Exchange (ETDEWEB)

    Pennartz, A.M.G.; Van den Bovenkamp, M.V. [KWA Bedrijfsadviseurs, Amersfoort (Netherlands)

    2012-08-15

    The EU member states are obliged to bring the EU F-gas and Ozone policy into operation, by minimalizing the R22 and F-gas emissions in cooperation with market parties. Factors that may guide the refrigerant emission policy are: leakage percentages per year (company level, sector, national level); emission quantities (company level, sector, national level); indirect indicators: knowledge, experience with refrigerating contractors, feed back to end users, proactive prevention by end users. At this moment there is no clear view of the emission percentages in practice with the end users. For this reason the Dutch Ministry of Infrastructure and the Environment, by NL Agency, has initiated a random test survey in the Dairy, Meat and Other Food sectors. The main goal is to obtain data on the size and trends of R22 and HFK emissions in the period 2007-2010 [Dutch] De EU-lidstaten dienen uitvoering te geven aan het EU F-gas en Ozon-beleid, door met de markt te streven naar minimale R22 en F-gas emissies bij de eindgebruikers. Indicatoren (trends) om het koudemiddel emissiebeleid op te kunnen sturen zijn: jaarlijks optredende lekpercentages (per bedrijf, sector, totaal NL); emissiehoeveelheden (per bedrijf, sector, totaal NL); indirecte factoren: kennis/ervaring in lekkagepreventie bij koelinstallateurs, terugkoppeling naar de opdrachtgevers, preventiebeleid/prioriteit vanuit de opdrachtgevers. Tot nu toe ontbreekt een scherp beeld van de optredende lekpercentages (grootte, trends) bij de eindverbruikers. Daarom is door het Ministerie van IenM, via Agentschap NL een steekproefonderzoek uitgezet in de sectoren Zuivel, Vlees en Overige voedingsmiddelen. Doel is een beeld te krijgen van de omvang en trend van de R22 en HFK-emissies over 2007-2010.

  2. Simulations of hydraulic fracturing and leakage in sedimentary basins

    Energy Technology Data Exchange (ETDEWEB)

    Lothe, Ane Elisabeth

    2004-01-01

    Hydraulic fracturing and leakage of water through the caprock is described from sedimentary basin over geological time scale. Abnormal pressure accumulations reduce the effective stresses in the underground and trigger the initiation of hydraulic fractures. The major faults in the basin define these pressure compartments. In this Thesis, basin simulations of hydraulic fracturing and leakage have been carried out. A simulator (Pressim) is used to calculate pressure generation and dissipitation between the compartments. The flux between the compartments and not the flow within the compartments is modelled. The Griffith-Coulomb failure criterion determines initial failure at the top structures of overpressured compartments, whereas the frictional sliding criterion is used for reactivation along the same fractures. The minimum horizontal stress is determined from different formulas, and an empirical one seems to give good results compared to measured pressures and minimum horizontal stresses. Simulations have been carried out on two datasets; one covering the Halten Terrace area and one the Tune Field area in the northern North Sea. The timing of hydraulic fracturing and amount of leakage has been quantified in the studies from the Halten Terrace area. This is mainly controlled by the lateral fluid flow and the permeability of the major faults in the basin. Low fault permeability gives early failure, while high fault permeabilities results in no or late hydraulic fracturing and leakage from overpressured parts of the basin. In addition to varying the transmissibility of all faults in a basin, the transmissibility across individual faults can be varied. Increasing the transmissibility across faults is of major importance in overpressured to intermediately pressured areas. However, to obtain change in the flow, a certain pressure difference has to be the situation between the different compartments. The coefficient of internal friction and the coefficient of frictional

  3. Temperature and leakage aware techniques to improve cache reliability

    Science.gov (United States)

    Akaaboune, Adil

    Decreasing power consumption in small devices such as handhelds, cell phones and high-performance processors is now one of the most critical design concerns. On-chip cache memories dominate the chip area in microprocessors and thus arises the need for power efficient cache memories. Cache is the simplest cost effective method to attain high speed memory hierarchy and, its performance is extremely critical for high speed computers. Cache is used by the microprocessor for channeling the performance gap between processor and main memory (RAM) hence the memory bandwidth is frequently a bottleneck which can affect the peak throughput significantly. In the design of any cache system, the tradeoffs of area/cost, performance, power consumption, and thermal management must be taken into consideration. Previous work has mainly concentrated on performance and area/cost constraints. More recent works have focused on low power design especially for portable devices and media-processing systems, however fewer research has been done on the relationship between heat management, Leakage power and cost per die. Lately, the focus of power dissipation in the new generations of microprocessors has shifted from dynamic power to idle power, a previously underestimated form of power loss that causes battery charge to drain and shutdown too early due the waste of energy. The problem has been aggravated by the aggressive scaling of process; device level method used originally by designers to enhance performance, conserve dissipation and reduces the sizes of digital circuits that are increasingly condensed. This dissertation studies the impact of hotspots, in the cache memory, on leakage consumption and microprocessor reliability and durability. The work will first prove that by eliminating hotspots in the cache memory, leakage power will be reduced and therefore, the reliability will be improved. The second technique studied is data quality management that improves the quality of the data

  4. Numerical Modeling of CO2 and Brine Leakage through Open Fracture in a Fault Zone: Open Channel Flow or Darcy Flow

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2017-01-01

    Full Text Available Understanding fluids migration and leakage risk along the fault zone is necessary to guarantee the safety of CO2 geological storage. The validity of Darcy’s law gets challenged in dealing with the flow in open fractures since the occurring of turbulence flow. In this study, we develop a 2D model with usage of T2Well, an integrated wellbore-reservoir simulator, to investigate the leakage problem along open fractures which are embedded in a fault zone from the deep injection reservoir to shallow aquifers. The results record a positive feedback of gas expansion and pressure response in fracture, which causes a quick downward propagation of highly gas saturated zone from the top of fracture and an easy gas breakthrough in the shallower aquifers. The decreasing of aperture size of fracture significantly enhances the leakage rates in fracture, but with less influences as aperture increases. In comparison, the Equivalent Porous Media models show a good approximation with the momentum model of large apertures but poor for the small one. Nevertheless, the differences are small in terms of final CO2 distribution among various aquifers, suggesting that Darcy’s law may be still “effective” in solving flow problem along fractures in a constant injection system at a large time scale.

  5. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  6. Assessment of different dyes used in leakage studies.

    Science.gov (United States)

    Mente, Johannes; Ferk, Stephan; Dreyhaupt, Jens; Deckert, Andreas; Legner, Milos; Staehle, Hans Joerg

    2010-06-01

    The goal of this in vitro study was to identify the most suitable dye for endodontic dye leakage studies, which could be a further step towards standardisation. The root canals of 70 extracted, single-rooted human adult teeth were enlarged to apical size 50 using hand instruments. The teeth were divided into seven groups (n = 10 each), and all root canals were completely filled by injection with one of the following dyes: methylene blue 0.5% and 5%, blue ink, black ink, eosin 5%, basic fuchsin 0.5% and drawing ink. Transverse root sections from the coronal, middle and apical part of the roots were examined, and the percentage of the dentine penetrated by dye was evaluated by software-supported light microscopy. In addition, the range of particle size of drawing ink particles was evaluated. There were conspicuous differences in the relative dye penetration into the root dentine and the penetration behaviour in the different root sections (two-way ANOVA, both p < 0.0001). One dye (drawing ink) penetrated less into the root dentine compared with all the others (p <0.0001). The particle size of this agent (0.1-2 microm) corresponds best with the size range of a representative selection of 21 species of pathogenic endodontic bacteria. Compared to the other dyes tested, drawing ink appears to be superior for use in endodontic dye leakage studies. The penetration behaviour into the root dentine of all the other dyes tested might be one factor that limits the applicability of these dyes in dye leakage studies.

  7. Contrast media for radiological examination in gastrointestinal tract leakage

    International Nuclear Information System (INIS)

    Ginai-Karamat, A.Z.

    1987-01-01

    The aim of this investigation has been to find a safe and suitable contrast medium (CM) for radiological evaluation of the gastrointestinal tract (GIT) in cases where leakage outside the GIT can be suspected. An experimental study was carried out to evaluate the reactions of various available CM in the bronchi and lungs, mediastinum, pleura and peritoneum of rats. The CM evaluated in the experimental study were, pure barium sulphate (without any additives), commercial barium sulphate (Micropaque, with additives), Dionosil, Hytrast, Gastrografin, Amipaque (in pleura Omnipaque) and Hexabrix. (Auth.)

  8. Large Epiphrenic Diverticulum with Perforation and Leakage below the Diaphragm

    DEFF Research Database (Denmark)

    Brønserud, Majken Munk; Brenøe, Anne-Sofie; Eckardt, Jens

    2015-01-01

    We present a rare case of an epiphrenic esophageal diverticulum, complicated by perforation and leakage below the diaphragm in a 57-year-old male patient. The patient was referred to the emergency department with suspected aspiration pneumonia. A thoracoabdominal computed tomography with oral...... to esophagus, ending blindly in a perforation below the diaphragm. The clinical presentation and the patient’s age make it most likely, that it was a long epiphrenic diverticulum of pulsion type. The patient was treated conservatively, discharged after 10 days and has been followed in our outpatient clinic...

  9. A nationwide study on anastomotic leakage after colonic cancer surgery

    DEFF Research Database (Denmark)

    Krarup, Peter-Martin; Jorgensen, L N; Andreasen, A H

    2012-01-01

    Aim: Anastomotic leakage (AL) is a major challenge in colorectal cancer surgery due to increased morbidity and mortality. Possible risk factors should be investigated differentially, distinguishing between rectal and colonic surgery in large-scale studies to avoid selection bias and confounding....... Method: The incidence and risk factors associated with AL were analysed in an unselected nation-wide prospective cohort of patient subjected to curative colonic cancer surgery with primary anastomosis and entered into The Danish Colorectal Cancer Group database between May 2001 and December 2008. Results...

  10. Design of Earth Leakage Circuit Breaker on Sensitivity 20 MA

    Directory of Open Access Journals (Sweden)

    Pandung Sarungallo

    2008-08-01

    Full Text Available Electrics current can flow out to the ground by using a human body. This electric current will be dangerous to the human when it exceed 20mA. A very sensitive earth leakage circuit breaker (ELCB is needed to anticipate the leaky current but most of ELCB can only be found in the market with sensitivitas 30mA or bigger. This research is succees to design an ELCB with sensitivity 20mA. Characteristic of an ELCB is very influenced by the current transformer characteristic and the relay which are used.

  11. Leakage radiation spectroscopy of organic/dielectric/metal systems

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Kawalec, Tomasz; Kostiučenko, Oksana

    2014-01-01

    side of a hemisphere fused silica prism with an index matching liquid was illuminated under normal incidence by a He-Cd 325 nm laser. Two orthogonal linear polarizations were used both parallel and perpendicular to the detection plane. Spectrally resolved leakage radiation was observed on the opposite...... excitons and surface plasmon polaritons (SPPs) of the metal/dielectric boundary. The presence of the SiO2 layer considerably changes the dispersion curve in comparison to the one of the Ag/p-6P/air system. However, the Ag/SiO2/p-6P/air stack forms a stable structure allowing construction of organic...

  12. Threats of Password Pattern Leakage Using Smartwatch Motion Recognition Sensors

    Directory of Open Access Journals (Sweden)

    Jihun Kim

    2017-06-01

    Full Text Available Thanks to the development of Internet of Things (IoT technologies, wearable markets have been growing rapidly. Smartwatches can be said to be the most representative product in wearable markets, and involve various hardware technologies in order to overcome the limitations of small hardware. Motion recognition sensors are a representative example of those hardware technologies. However, smartwatches and motion recognition sensors that can be worn by users may pose security threats of password pattern leakage. In the present paper, passwords are inferred through experiments to obtain password patterns inputted by users using motion recognition sensors, and verification of the results and the accuracy of the results is shown.

  13. Decreased Leakage Rate of Colonic Anastomoses by Tachosil Coating

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian; Achiam, Michael Patrick; Burcharth, Jakob

    2014-01-01

    Colorectal anastomotic coating has been proposed as a means to lower the leakage rate. Prior to clinical testing, coating materials need thorough experimental evaluation to ensure safety and efficacy. The aim of this study was to evaluate Tachosil as an anastomotic coating agent. Technically...... coating (10/40 versus 20/40 in controls; P=0.037). However, more cases of large bowel obstruction were found in the Tachosil group (12/40 versus 0/40 in controls; P... studies are needed to clarify the efficacy of Tachosil anastomotic coating....

  14. Risk factors for clinical anastomotic leakage after right hemicolectomy

    DEFF Research Database (Denmark)

    Jessen, Mikkel; Nerstrøm, Malene; Wilbek, Therese Emilie

    2016-01-01

    PURPOSE: Anastomotic leakage (AL) after right hemicolectomy is a devastating complication, and risk factors for AL in this setting are rarely investigated exclusively. Recent reports suggest that anastomotic type may influence the rate of AL in ileocolic anastomoses. We investigated risk factors...... and short-term outcomes in patients subjected to right hemicolectomy. METHODS: Data from all patients undergoing right hemicolectomy at our institution between 2009 and 2013 were collected in a database. Risk factors for clinical AL, 30-day mortality, hospital and intensive care unit stay were investigated...... after right hemicolectomy were diabetes, tobacco use and stapled compared with handsewn anastomoses....

  15. Early localization of containment leakage during an accident

    International Nuclear Information System (INIS)

    Pepin, P.; Chauliac, C.; Libmann, M.; Martinez, J.M.

    1990-01-01

    In case of an accident in a nuclear plant, checking the containment leaktightness would be a fundamental step for the diagnosis and prognosis of the radiological consequences. Significant help in this task can be provided by softwares. For that purpose, the French Atomic Energy Commission (CEA) is developing an expert system which can provide early in the accident a classification of the possible leakage paths and help understanding the necessary corrections which have to be undertaken by the utility. This software will be used at the Emergency Technical Center of the CEA. Its basic principles are described in this paper

  16. High ratio recirculating gas compressor

    Science.gov (United States)

    Weinbrecht, J.F.

    1989-08-22

    A high ratio positive displacement recirculating rotary compressor is disclosed. The compressor includes an integral heat exchanger and recirculation conduits for returning cooled, high pressure discharge gas to the compressor housing to reducing heating of the compressor and enable higher pressure ratios to be sustained. The compressor features a recirculation system which results in continuous and uninterrupted flow of recirculation gas to the compressor with no direct leakage to either the discharge port or the intake port of the compressor, resulting in a capability of higher sustained pressure ratios without overheating of the compressor. 10 figs.

  17. Continuum removed band depth analysis for detecting the effects of natural gas, methane and ethane on maize reflectance

    NARCIS (Netherlands)

    Noomen, M.F.; Skidmore, A.K.; Meer, van der F.D.; Prins, H.H.T.

    2006-01-01

    It is known that natural gas in the soil affects vegetation health, which may be detected through analysis of reflectance spectra. Since natural gas is invisible, changes in the vegetation could potentially indicate gas leakage. Although it is known that gas in soil affects plant reflectance, the

  18. Natural gas; Gas Natural

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Carlos A.; Moraes, Claudia C.D. [Eletricidade de Sao Paulo S.A. (ELETROPAULO), Sao Paulo, SP (Brazil); Fonseca, Carlos H.F. [Centrais Eletricas de Santa Catarina S.A., Florianopolis, SC (Brazil); Silva, Clecio Fabricio da; Alves, Ricardo P. [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil); Sposito, Edivaldo Soares; Hulle, Lutero [Espirito Santo Centrais Eletricas S.A. (ESCELSA), Vitoria, ES (Brazil); S. Martins, Icaro da [Centrais Eletricas do Norte do Brasil S.A. (ELETRONORTE), Belem, PA (Brazil); Vilhena, Joao Luiz S. de [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Fagundes, Zaluar Aquino [Companhia Estadual de Energia Eletrica do Estado do Rio Grande do Sul, Porto Alegre, RS (Brazil)

    1996-12-31

    An increase in the consumption of natural gas in Brazil is an expected fact in what concerns energetic planning. This work presents the existing situation in what concerns natural gas utilization in the main world economies, as well as an analysis of the participation of this fuel among the energy final consumption per sources. The Brazilian consumption of natural gas is also analysed as well as the international agreement between Brazil and Bolivia for natural gas commercialization. Some legal, institutional and political aspects related to natural gas commercialization are also discussed. Finally, several benefits to be brought by the utilization of natural gas are presented 10 refs., 3 tabs.

  19. On the calculation of leakage rates from vessels filled with high density gaseous CO2 using pressure drop data

    International Nuclear Information System (INIS)

    George, A.F.

    1987-09-01

    This paper considers calculation methods to estimate leakage rates from pressure drop data from vessels filled with high pressure (40 bar) low temperature (25 0 C) CO 2 . It is essential to consider the non-ideality of CO 2 under these conditions if accurate results are to be obtained. There are two main areas where this is relevant: the first is the use of temperature measurements to adjust the measured pressure readings so that the effect of temperature fluctuations is eliminated. The second is in the conversion of the pressure drop data to volumetric leak rate. An example test is described in which it is shown that the CO 2 based temperature correction method improves the accuracy of the pressure drop estimate by about a factor of ten over using a perfect gas assumption and a factor of about 25 over not attempting to adjust the pressure at all. Also the flow rate obtained from assuming the gas was perfect was almost a factor of two too low. A method for scaling leakage rates to other temperature pressures and gases is also given brief consideration in this report. It is observed that the results of scaling are strongly dependent on the flow regime assumed and it is not possible to determine the flow regime from the pressure drop data. Consequently only upper and lower bounds to the scaled estimate can be quoted. (U.K.)

  20. Environmental Impact of Natural Gas Hydrate Production

    Science.gov (United States)

    Max, M. D.; Johnson, A. H.

    2017-12-01

    Unmet conventional energy demand is encouraging a number of deep energy importing nations closer to production of their potentially very large Natural Gas Hydrate (NGH) resources. As methane and other natural gases are potent greenhouse gases, concerns exist about the possible environmental risks associated NGH development. Accidental of natural gas would have environmental consequences. However, the special characteristics of NGH and production models indicate a very low environmental risk from the reservoir to the deepwater wellhead that is much lower than for conventional deepwater gas. NGH is naturally stable in its solid form in the reservoir and shutting in the gas can be achieved by stopping NGH conversion and gas production in the reservoir. Rapid shut down results in re-crystallization of gas and stabilization of the reservoir through NGH reformation. In addition, new options for innovative technologies have the potential to allow safe development of NGH at a fraction of the current estimated cost. Gas produced from NGH is about the same as processed conventional gas, although almost certainly more pure. Leakage of gas during transport is not a production issue. Gas transport leakage is a matter for best practices regulation that is rigorously enforced.

  1. Application Of The Climafor Baseline To Determine Leakage: TheCase Of Scolel Te.

    Energy Technology Data Exchange (ETDEWEB)

    De Jong, B.H.J.; Bazan, E. Esquivel; Quechulpa Montalvo, S.

    2007-06-01

    The acceptance of forestry-based project activities tomitigate greenhouse gases emissions has been subjected to a number ofmethodological questions to be answered, of which the most challengingare baseline establishment and identification of and measuring leakage.Here we pose hypotheses for and quantify leakage of the Scolel Te projectin Chiapas, Mexico. In this project small-scale farmers are implementingforestry, agroforestry, and forest conservation activities, with carbonsequestration as one of the goals. The main leakage monitoring domain isdefined as the area owned by the participating farmers or communitiesoutside the area where the specific project activities take place. Thenull-hypothesis (no leakage) is that non-project land owned by the farmeror community will experience the same carbon stock changes as predictedby the regional baseline, specifically developed for the project. Firstwe assessed the most likely causes and sources of leakage that may occurin the project. From this analysis, one type of leakage seems to beimportant, i.e., activity shifting. Second we estimated the leakage of asample of participating farmers and communities. Actual land use was thencompared with expected land use derived from the baseline. The Plan Vivoof each participant, complemented with readily available tools toidentify the main sources and drivers of leakage are used to developsimple leakage assessment procedures, as demonstrated in this paper.Negative leakage was estimated to be negligible in this study.Incorporating these procedures already in the project planning stage willreduce the uncertainties related to the actual carbon mitigationpotential of any forestry project.

  2. Information leakage analysis of software: How to make it useful to IT industries?

    Directory of Open Access Journals (Sweden)

    Kushal Anjaria

    2017-06-01

    Full Text Available Nowadays the software is becoming complex as clients expect a number of functionalities in software. In such scenario, information leakage can't be avoided. As a result, a lot of research is going on to develop tools, methods and policies to find and minimize the leakage. The paper proposes a method to provide a measure, especially to the IT organizations to find how the information leakage at one portion of the software can propagate leakage risk to the other portions of the software or entire software. The paper uses the quantitative analysis of information leakage and cost function based statistical method to find the leakage risk propagation in the software. The method proposed in the paper facilitates the organizations by allowing them to set the organization specific parameters. The proposed method has been applied to the function of Linux to demonstrate the information leakage risk propagation. When organizations find information leakage in the software, their sustaining engineering or quality management teams simply rectify the software portion. But it becomes difficult for the organizations to document the overall mitigation of the risk of leakage. Thus, using the proposed method, organizations will be able to quantify the information leakage risk mitigation.

  3. Gas and Gas Pains

    Science.gov (United States)

    ... Gas and gas pains Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  4. Coupling of Multiphase Flow and Geomechanics in Fractured Porous Media: Application to CO2 Leakages from Natural and Stimulated Fractures

    Science.gov (United States)

    Ezzedine, S. M.

    2015-12-01

    Leakage to the atmosphere of a significant fraction of injected CO2 would constitute a failure of a geological CO2 storage project from a greenhouse gas mitigation perspective. We present a numerical model that simulates flow and transport of CO2 into heterogeneous subsurface systems. The model, StoTran, is a flexible numerical environment that uses state-of-the-art finite element and finite volume methods and unstructured adaptive mesh refinement scheme implemented using MPI and OpenMP protocols. Multiphase flow equations and the geomechanical equations are implicitly solved and either fully or sequentially coupled. StoTran can address inverse and forward problems under deterministic or stochastic conditions. For the current study, StoTran has been used to simulate several scenarios spanning from a homogeneous single layered reservoir to heterogeneous multi-layered systems, which including cap-rock with embedded fractures, have been simulated under different operations of CO2 injection and CO2 leakages conditions. Results show the impact of the injection and leakage rates on the time evolution of the spread of the CO2 plume, its interception of the fractured cap-rock and the risk associated with the contamination of the overlaying aquifer. Spatial and temporal moments have been calculated for different, deterministic of stochastic, subsurface physical and chemical properties. Spatial moments enable assessing the extent of the region of investigation under conditions of uncertainty. Furthermore, several leakage scenarios show the intermittence behavior and development of the CO2 plume in the subsurface; its first interception with the fractures located further far from the injection well then, at a second stage, its interception with the fracture within the immediate vicinity of the injection well. We will present a remedy to CO2 leakages from the reservoir in order to enhance a long term containment of the injected CO2. This work performed under the auspices of

  5. Angiopoietin-2 is critical for cytokine-induced vascular leakage.

    Directory of Open Access Journals (Sweden)

    Andrew V Benest

    Full Text Available Genetic experiments (loss-of-function and gain-of-function have established the role of Angiopoietin/Tie ligand/receptor tyrosine kinase system as a regulator of vessel maturation and quiescence. Angiopoietin-2 (Ang-2 acts on Tie2-expressing resting endothelial cells as an antagonistic ligand to negatively interfere with the vessel stabilizing effects of constitutive Ang-1/Tie-2 signaling. Ang-2 thereby controls the vascular response to inflammation-inducing as well as angiogenesis-inducing cytokines. This study was aimed at assessing the role of Ang-2 as an autocrine (i.e. endothelial-derived regulator of rapid vascular responses (within minutes caused by permeability-inducing agents. Employing two independent in vivo assays to quantitatively assess vascular leakage (tracheal microsphere assay, 1-5 min and Miles assay, 20 min, the immediate vascular response to histamine, bradykinin and VEGF was analyzed in Ang-2-deficient (Ang-2(-/- mice. In comparison to the wild type control mice, the Ang2(-/- mice demonstrated a significantly attenuated response. The Ang-2(-/- phenotype was rescued by systemic administration (paracrine of an adenovirus encoding Ang-2. Furthermore, cytokine-induced intracellular calcium influx was impaired in Ang-2(-/- endothelioma cells, consistent with reduced phospholipase activation in vivo. Additionally, recombinant human Ang-2 (rhAng-2 alone was unable to induce vascular leakage. In summary, we report here in a definite genetic setting that Ang-2 is critical for multiple vascular permeability-inducing cytokines.

  6. Secure Mobile Agent from Leakage-Resilient Proxy Signatures

    Directory of Open Access Journals (Sweden)

    Fei Tang

    2015-01-01

    Full Text Available A mobile agent can sign a message in a remote server on behalf of a customer without exposing its secret key; it can be used not only to search for special products or services, but also to make a contract with a remote server. Hence a mobile agent system can be used for electronic commerce as an important key technology. In order to realize such a system, Lee et al. showed that a secure mobile agent can be constructed using proxy signatures. Intuitively, a proxy signature permits an entity (delegator to delegate its signing right to another entity (proxy to sign some specified messages on behalf of the delegator. However, the proxy signatures are often used in scenarios where the signing is done in an insecure environment, for example, the remote server of a mobile agent system. In such setting, an adversary could launch side-channel attacks to exploit some leakage information about the proxy key or even other secret states. The proxy signatures which are secure in the traditional security models obviously cannot provide such security. Based on this consideration, in this paper, we design a leakage-resilient proxy signature scheme for the secure mobile agent systems.

  7. Low standby leakage 12T SRAM cell characterisation

    Science.gov (United States)

    Yadav, Arjun; Nakhate, Sangeeta

    2016-09-01

    In this work, a low power and variability-aware static random access memory (SRAM) architecture based on a twelve-transistor (12T) cell is proposed. This cell obtains low static power dissipation due to a parallel global latch (G-latch) and storage latch (S-latch), along with a global wordline (GWL), which offer a high cell ratio and pull-up ratio for reliable read and write operations and a low cell ratio and pull-up ratio during idle mode to reduce the standby power dissipation. In the idle state, only the S-latch stores bits, while the G-latch is isolated from the S-latch and the GWL is deactivated. The leakage power consumption of the proposed SRAM cell is thereby reduced by 38.7% compared to that of the conventional six-transistor (6T) SRAM cell. This paper evaluates the impact of the chip supply voltage and surrounding temperature variations on the standby leakage power and observes considerable improvement in the power dissipation. The read/write access delay, read static noise margin (SNM) and write SNM were evaluated, and the results were compared with those of the standard 6T SRAM cell. The proposed cell, when compared with the existing cell using the Monte Carlo method, shows an appreciable improvement in the standby power dissipation and layout area.

  8. Intestinal protein leakage in the acquired immunodeficiency syndrome.

    Science.gov (United States)

    Becker, K; Lindner, C; Frieling, T; Niederau, C; Reinauer, H; Häussinger, D

    1997-09-01

    Body wasting, protein catabolism, and hypoalbuminemia are complicating features of the acquired immunodeficiency syndrome (AIDS). Given their multifactorial causes, the contributing role of intestinal protein loss has not yet been fully elucidated. To quantify enteric protein leakage, determination of fecal alpha 1-antitrypsin (AAT) excretion has been established as an accurate and reliable endogenous marker. We estimated AAT concentration by standard immune nephelometry in duplicate random stool samples of 49 patients with AIDS, and we compared it to that of 43 patients with chronic inflammatory bowel disease and to 34 healthy controls. When compared with healthy persons, patients with AIDS had increased fecal AAT excretion regardless of current opportunistic intestinal infections and fecal AAT excretion similar to that of patients with quiescent chronic inflammatory bowel disease. The ratio of fecal and serum AAT concentration was not different between AIDS patients and healthy controls, although it was consistently increased in those with chronic inflammatory bowel disease. Significant intestinal protein leakage occurs in patients with AIDS, probably due to primary impairment of gut permeability. Enteric protein loss may be an important feature of human immunodeficiency virus-associated enteropathy with altered mucosal barrier function.

  9. Sensors for online determination of CNG gas quality; Sensorer foer onlinebestaemnning av fordonsgaskvalitet

    Energy Technology Data Exchange (ETDEWEB)

    Stenlaaaas, Ola; Roedjegaard, Henrik

    2012-07-01

    Swedish automotive gas has until now been a very uniform, high quality automotive fuel. Elsewhere in Europe the quality of automotive gas varies significantly. Gas from different sources with different flammability require engine settings adjusted to the chosen gas' unique composition. The prospects for a vehicle-mounted sensor based on infrared technology for gas quality measurement has been studied and solutions are presented with questions that must be answered in a possible future work. The proposed vehicle mounted sensor is based on two channels, one of which measures the partial pressure of methane and the other measures the partial pressure of heavier hydrocarbons in 'equivalents of butane'. Ethane produces a signal of about 0.6 equivalents of butane and propane about 0.8 equivalents. The sensor can be accommodated in a cube with 5 cm side and should be equipped with nipple connections to the existing system. The sensor is expected to work throughout their entire lifetime without manual calibration, through continuous automatic calibration, so-called ABC (Automatic Baseline Compensation). The sensor will have to meet tough quality and environmental standards in which primarily contact ring, vibration and prevention of leakage are identified as extra difficult. Working temperatures and the electrical conditions of power supply and communication interface is considered less challenging. In one million volumes, the cost per sensor could be 200 to 300 SEK.

  10. Uncertainty Analysis of In leakage Test for Pressurized Control Room Envelop

    International Nuclear Information System (INIS)

    Lee, J. B.

    2013-01-01

    In leakage tests for control room envelops(CRE) of newly constructed nuclear power plants are required to prove the control room habitability. Results of the in leakage tests should be analyzed using an uncertainty analysis. Test uncertainty can be an issue if the test results for pressurized CREs show low in leakage. To have a better knowledge of the test uncertainty, a statistical model for the uncertainty analysis is described here and a representative uncertainty analysis of a sample in leakage test is presented. A statistical method for analyzing the uncertainty of the in leakage test is presented here and a representative uncertainty analysis of a sample in leakage test was performed. By using the statistical method we can evaluate the test result with certain level of significance. This method can be more helpful when the difference of the two mean values of the test result is small

  11. A study on two phase flows of linear compressors for the prediction of refrigerant leakage

    International Nuclear Information System (INIS)

    Hwang, Il Sun; Lee, Young Lim; Oh, Won Sik; Park, Kyeong Bae

    2015-01-01

    Usage of linear compressors is on the rise due to their high efficiency. In this paper, leakage of a linear compressor has been studied through numerical analysis and experiments. First, nitrogen leakage for a stagnant piston with fixed cylinder pressure as well as for a moving piston with fixed cylinder pressure was analyzed to verify the validity of the two-phase flow analysis model. Next, refrigerant leakage of a linear compressor in operation was finally predicted through 3-dimensional unsteady, two phase flow CFD (Computational fluid dynamics). According to the research results, the numerical analyses for the fixed cylinder pressure models were in good agreement with the experimental results. The refrigerant leakage of the linear compressor in operation mainly occurred through the oil exit and the leakage became negligible after about 0.4s following operation where the leakage became lower than 2.0x10 -4 kg/s.

  12. Investigation of pool thermal hydraulics and temperature distribution in inner vessel under mechanical seal leakage

    International Nuclear Information System (INIS)

    Abraham, Juby; Velusamy, K.; Selvaraj, P.

    2015-01-01

    The primary heat sink of prototype fast breeder reactor is a sodium pool which is partitioned into cold pool and hot pool. The inner vessel which separates the cold and hot pools is having penetrations for intermediate heat exchangers. The hot sodium from hot pool leaks into the cold pool through these penetrations and to reduce the leakage, mechanical seals are provided. Leakage of hot sodium into cold pool can lead to thermal stratification in the cold pool and also will affect the temperature distribution in inner vessel. 3-D CFD studies were performed focusing these features as a function of sodium leakage. The analyses indicate that the maximum temperature difference across the IV thickness is 65°C without any leakage of sodium. The temperature difference is found to decrease with increase in leakage through the seals. It is seen that a leakage of 2.5% is acceptable. (author)

  13. Infrared Gas Sensor

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    In recent years, the rapid development of monitoring and detecting technology of indoor air quality have been observed. We have seen the two major streams of detection technology introduced so far: Acoustic wave sensor and Infrared gas sensor. The use of a gas monitoring system in the case of that dangerous levels of gases are detected, can help to prevent an explosion or can help to prevent worker injury or exposure to toxic gases.

  14. Analysis of Gas Leakage and Current Loss of Solid Oxide Fuel Cells by Screen Printing

    DEFF Research Database (Denmark)

    Jia, Chuan; Han, Minfang; Chen, Ming

    2017-01-01

    operating life and lead to performance degradation. The planar anode-supported Ni-YSZ|YSZ|LSCF SOFC was chosen as the research object, with the cell size of 12cm×12cm and the effective area of 100cm2, and the holder is made of 99% purity of Al2O3 ceramic material, in order to eliminate the influence of Cr...... in stainless steel. The one-cell stack operated at 750℃, and the maximum power density was 0.35W/cm2 when the fuel is 0.5slm/min pure hydrogen. The stability experiment was conducted first under pure H2 for 100h, then fuel was switched into pure methane, and another 100h of voltage stability was tested....... In this work, the temperature distribution of the stack was monitored, whose relationship with the weight gain and the micro-structure of the nickel foam was established, and a possible explanation of the carbon deposition distribution and process on the nickel foam was put forward....

  15. Failure analysis of leakage caused by perforation in an L415 steel gas pipeline

    Directory of Open Access Journals (Sweden)

    Zhiyong Liu

    2017-10-01

    Full Text Available The reasons for the failure of a buried pipeline perforated during construction were investigated by a chemical composition analysis; a metallographic test; macromorphology observation; characterization of the corrosion products by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction; field medium characterization; and an analysis of the working conditions. The results revealed that the material composition and organization of the steel pipe conformed to API Specification 5CT. However, the reason for the perforation of the L415 steel pipe was an ultrahigh growth rate of pitting corrosion, as high as 14 mm per year. We confirmed that the synergistic effect of a high partial pressure of oxygen introduced by an improper packing process and concentrated Cl− in the corrosion product layer, which originated from groundwater with a high salt concentration that was used for the water pressure test, were responsible for the failure process.

  16. Estimation of leakage power and delay in CMOS circuits using parametric variation

    Directory of Open Access Journals (Sweden)

    Preeti Verma

    2016-09-01

    Full Text Available With the advent of deep-submicron technologies, leakage power dissipation is a major concern for scaling down portable devices that have burst-mode type integrated circuits. In this paper leakage reduction technique HTLCT (High Threshold Leakage Control Transistor is discussed. Using high threshold transistors at the place of low threshold leakage control transistors, result in more leakage power reduction as compared to LCT (leakage control transistor technique but at the scarifies of area and delay. Further, analysis of effect of parametric variation on leakage current and propagation delay in CMOS circuits is performed. It is found that the leakage power dissipation increases with increasing temperature, supply voltage and aspect ratio. However, opposite pattern is noticed for the propagation delay. Leakage power dissipation for LCT NAND gate increases up to 14.32%, 6.43% and 36.21% and delay decreases by 22.5%, 42% and 9% for variation of temperature, supply voltage and aspect ratio. Maximum peak of equivalent output noise is obtained as 127.531 nV/Sqrt(Hz at 400 mHz.

  17. The Analysis and Comparison of Leakage Inductance in Different Winding Arrangements for Planar Transformer

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Thomsen, Ole Cornelius; Andersen, Michael Andreas E.

    2009-01-01

    to reduce leakage inductance further. Some important issues are presented to acquire desired leakage inductance. The design and modeling of 1 kW planar transformer is presented. In order to verify the analytical method for leakage inductance in this paper, finite element analysis (FEA) and measurement...... (MMF) and energy distribution in planar transformer and correct the formula of leakage inductance proposed by previous publications. The investigation of different winding arrangements shows significant advantages of interleaving structure. In this work, a novel half turn structure is proposed...

  18. Investigations of leakage mechanisms and its influences on a micro swing engine considering rarefaction effects

    International Nuclear Information System (INIS)

    Zhou, Xiong; Zhang, Zhenyu; Kong, Wenjun; Du, Ning

    2016-01-01

    Highlights: • Mechanisms of the leakage flow in different flow regimes have been studied. • The leakage flow regime and patterns in the micro swing engine are presented. • Slip on the walls has a larger effect on leakage flow with decreasing the gap. • Rarefaction effects on the engine performance have been investigated. - Abstract: Considering rarefaction effects, this paper investigated mechanisms of the clearance leakage and its influences on a micro swing engine for the micro power generation by employing three different flow models named as discrete velocity direction (DVD) model, Navier-Stokes equations with slip boundary conditions (NS-slip) and no-slip boundary conditions (NS-no slip). Using the DVD model, this paper firstly studied leakage mechanisms of a micro Couette-Poisueille flow. Factors which control the leakage in different regimes were obtained. Furthermore, the system-level predictions of the clearance leakage in the micro swing engine have been conducted by solving the Navier-Stokes equations. The leakage flow regime, patterns and characteristics were presented. Results by NS-slip and NS-no slip were compared to study the rarefaction effects. Finally, investigations of the engine size and the gap height on the engine performance have been conducted. The significance of the leakage in different engine size regimes was presented, and the results show that rarefaction effects affect the indicated thermal efficiency greatly with the decrease of the engine size scale.

  19. Behavior of AC High Voltage Polyamide Insulators: Evolution of Leakage Current in Different Surface Conditions

    Directory of Open Access Journals (Sweden)

    Mohammed El Amine Slama

    2015-01-01

    Full Text Available This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a nonlinear regime up to total flashover of the insulators sting. Traces of erosion and tracking of insulators resulting of partial discharges are observed.

  20. Detection of gaseous heavy water leakage points in CANDU 6 pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Park, T-K.; Jung, S-H.

    1996-01-01

    During reactor operation, the heavy water filled primary coolant system in a CANDU 6 Pressurized Heavy Water (PHWR) may leak through routine operations of the plant via components, mechanical joints, and during inadvertent operations etc. Early detection of leak points is therefore important to maintain plant safety and economy. There are many independent systems to monitor and recover heavy water leakage in a CANDU 6 PHWR. Methodology for early detection based on operating experience from these systems, is investigated in this paper. In addition, the four symptoms of D 2 O leakage, the associated process for clarifying and verifying the leakage, and the probable points of leakage are discussed. (author)

  1. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  2. Application of a leakage model to assess exfiltration from sewers.

    Science.gov (United States)

    Karpf, C; Krebs, P

    2005-01-01

    The exfiltration of wastewater from sewer systems in urban areas causes a deterioration of soil and possibly groundwater quality. Beside the simulation of transport and degradation processes in the unsaturated zone and in the aquifer the analysis of the potential impact requires the estimation of quantity and temporal variation of wastewater exfiltration. Exfiltration can be assessed by the application of a leakage model. The hydrological approach was originally developed to simulate the interactions between the groundwater and surface water, it was adapted to allow for modelling of interactions between groundwater and sewer system. In order to approximate the exfiltration specific model parameters infiltration specific parameters were used as a basis. Scenario analysis of the exfiltration in the City of Dresden from 1997 to 1999 and during the flood event in August 2002 shows the variation and the extent of exfiltration rates.

  3. A Study of Neutron Leakage in Finite Objects

    Science.gov (United States)

    Wilson, John W.; Slaba, Tony C.; Badavi, Francis F.; Reddell, Brandon D.; Bahadori, Amir A.

    2015-01-01

    A computationally efficient 3DHZETRN code capable of simulating High charge (Z) and Energy (HZE) and light ions (including neutrons) under space-like boundary conditions with enhanced neutron and light ion propagation was recently developed for simple shielded objects. Monte Carlo (MC) benchmarks were used to verify the 3DHZETRN methodology in slab and spherical geometry, and it was shown that 3DHZETRN agrees with MC codes to the degree that various MC codes agree among themselves. One limitation in the verification process is that all of the codes (3DHZETRN and three MC codes) utilize different nuclear models/databases. In the present report, the new algorithm, with well-defined convergence criteria, is used to quantify the neutron leakage from simple geometries to provide means of verifying 3D effects and to provide guidance for further code development.

  4. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States); Shaffer, M. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  5. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  6. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  7. Leakage detection system for radioactive waste storage tanks

    International Nuclear Information System (INIS)

    Woods, W.W.; Eul, W.A.

    1979-01-01

    The patent describes a combination of elements for detecting leakage of electrically conductive fluids from tanks, including a reference electrode, an AC generator connected between the tank and the reference electrode, and one or more sensing electrodes positioned between the tank and the reference electrode. The storage tank and reference electrode are in contact with the ground. When the AC generator is energized, current flows in the circuit, and creates an electric field in the ground between the tank and the reference electrode. The sensing electrodes are positioned so that they are within the electric field when the AC generator is energized. An electric potential measuring device, such as a voltmeter, is used to measure the electric potential at the sensing electrodes relative to the tank. A significant change in the electric potential at any one or more of the sensing electrodes is an indication that a leak has occurred in the tank

  8. Probabilistic modeling of caprock leakage from seismic reflection data

    DEFF Research Database (Denmark)

    Zunino, Andrea; Hansen, Thomas Mejer; Bergjofd-Kitterød, Ingjerd

    We illustrate a methodology which helps to perform a leakage risk analysis for a CO2 reservoir based on a consistent, probabilistic approach to geophysical and geostatistical inversion. Generally, risk assessments of storage complexes are based on geological models and simulations of CO2 movement...... within the storage complexes. The geological models are built on top of geophysical data such as seismic surveys, geological information and well logs from the reservoir or nearby regions. The risk assessment of CO2 storage requires a careful analysis which accounts for all sources of uncertainty....... However, at present, no well-defined and consistent method for mapping the true uncertainty related to the geophysical data and how that uncertainty affects the overall risk assessment for the potential storage site is available. To properly quantify the uncertainties and to avoid unrealistic...

  9. Quench tank in-leakage diagnosis at St. Lucie

    International Nuclear Information System (INIS)

    Price, J.E.; Au-Yang, M.K.; Beckner, D.A.; Vickery, A.N.

    1996-01-01

    In February 1995, leakage into the quench tank of the St. Lucie Nuclear Station Unit 1 was becoming an operational concern. This internal leak resulted in measurable increases in both the temperature and level of the quench tank water, and was so severe that, if the trend continued, plant shut down would be necessary. Preliminary diagnosis based on in-plant instrumentation indicated that any one of 11 valves might be leaking into the quench tank. This paper describes the joint effort by two teams of engineers--one from Florida Power ampersand Light, the other from Framatome Technologies--to identify the sources of the leak, using the latest technology developed for valve diagnosis

  10. Quench tank in-leakage diagnosis at St. Lucie

    Energy Technology Data Exchange (ETDEWEB)

    Price, J.E.; Au-Yang, M.K.; Beckner, D.A.; Vickery, A.N.

    1996-12-01

    In February 1995, leakage into the quench tank of the St. Lucie Nuclear Station Unit 1 was becoming an operational concern. This internal leak resulted in measurable increases in both the temperature and level of the quench tank water, and was so severe that, if the trend continued, plant shut down would be necessary. Preliminary diagnosis based on in-plant instrumentation indicated that any one of 11 valves might be leaking into the quench tank. This paper describes the joint effort by two teams of engineers--one from Florida Power & Light, the other from Framatome Technologies--to identify the sources of the leak, using the latest technology developed for valve diagnosis.

  11. Remote sensing of CO2 leakage from geologic sequestration projects

    Science.gov (United States)

    Verkerke, Joshua L.; Williams, David J.; Thoma, Eben

    2014-09-01

    Monitoring for leak hazards is an important consideration in the deployment of carbon dioxide geologic sequestration. Failure to detect and correct leaks may invalidate any potential emissions benefits intended by such projects. Presented is a review of remote sensing methods primed to serve a central role in any monitoring program due to their minimally invasive nature and potential for large area coverage in a limited timeframe or in real-time as a continuous monitoring program. Methods investigated were divided into those capable of indirect detection of carbon dioxide leakage, such as monitoring for vegetative stress and ground surface deformation, and those that directly detect gaseous and atmospheric compounds, by means of such tools as Open-Path Fourier Transform Infrared or Tunable Diode Lasers. Both direct and indirect methods present viable means of detecting a leak event, though ultimately, a robust approach will incorporate multiple monitoring tools that may include both direct and indirect remote sensing methods.

  12. Centrifugal gas separator

    International Nuclear Information System (INIS)

    Sakurai, Mitsuo.

    1970-01-01

    A centrifugal gas separator of a highly endurable construction and with improved gas sealing qualities utilizes a cylincrical elastic bellows or similar system in cooperation with a system of dynamic pressure operable gas seals as means for removing separated gases from the interior of the rotor drum, collecting the separated gases in their respective separated gas chambers defined by the corresponding bellows and their supporting stationary wall members, gas seals and rotor end caps, and means for discharging to the exterior of the surrounding cylindrical wall member the gaseous components from their respective separated gas chambers. In the vicinity of the rotary drum motor is a mixed gas chamber and means for providing the gas mixture along a co-axial passage into the rotary drum chamber. Orifices are bored into the end caps of the rotary drum to direct the separated gases into the aforementioned separated gas chambers which, through the action of the gas seals, freely slide upon the rotating drum to collect and thereafter discharge the thus separated gases. Therefore, according to the present invention, helium gas used to prevent separated gas remixture is unnecessary and, furthermore, the gas seals and elastic bellows means provide an air-tight seal superior to that of the contact sealing system of the former art. (K.J. Owens)

  13. Angiopoietin-2 Is Critical for Cytokine-Induced Vascular Leakage

    Science.gov (United States)

    Thomas, Markus; Laib, Anna M.; Loos, Elias K.; Fiedler, Ulrike; Augustin, Hellmut G.

    2013-01-01

    Genetic experiments (loss-of-function and gain-of-function) have established the role of Angiopoietin/Tie ligand/receptor tyrosine kinase system as a regulator of vessel maturation and quiescence. Angiopoietin-2 (Ang-2) acts on Tie2-expressing resting endothelial cells as an antagonistic ligand to negatively interfere with the vessel stabilizing effects of constitutive Ang-1/Tie-2 signaling. Ang-2 thereby controls the vascular response to inflammation-inducing as well as angiogenesis-inducing cytokines. This study was aimed at assessing the role of Ang-2 as an autocrine (i.e. endothelial-derived) regulator of rapid vascular responses (within minutes) caused by permeability-inducing agents. Employing two independent in vivo assays to quantitatively assess vascular leakage (tracheal microsphere assay, 1–5 min and Miles assay, 20 min), the immediate vascular response to histamine, bradykinin and VEGF was analyzed in Ang-2-deficient (Ang-2−/−) mice. In comparison to the wild type control mice, the Ang2−/− mice demonstrated a significantly attenuated response. The Ang-2−/− phenotype was rescued by systemic administration (paracrine) of an adenovirus encoding Ang-2. Furthermore, cytokine-induced intracellular calcium influx was impaired in Ang-2−/− endothelioma cells, consistent with reduced phospholipase activation in vivo. Additionally, recombinant human Ang-2 (rhAng-2) alone was unable to induce vascular leakage. In summary, we report here in a definite genetic setting that Ang-2 is critical for multiple vascular permeability-inducing cytokines. PMID:23940579

  14. SETI via Leakage from Light Sails in Exoplanetary Systems

    Science.gov (United States)

    Guillochon, James; Loeb, Abraham

    2015-10-01

    The primary challenge of rocket propulsion is the burden of needing to accelerate the spacecraft’s own fuel, resulting in only a logarithmic gain in maximum speed as propellant is added to the spacecraft. Light sails offer an attractive alternative in which fuel is not carried by the spacecraft, with acceleration being provided by an external source of light. By artificially illuminating the spacecraft with beamed radiation, speeds are only limited by the area of the sail, heat resistance of its material, and power use of the accelerating apparatus. In this paper, we show that leakage from a light sail propulsion apparatus in operation around a solar system analogue would be detectable. To demonstrate this, we model the launch and arrival of a microwave beam-driven light sail constructed for transit between planets in orbit around a single star, and find an optimal beam frequency on the order of tens of GHz. Leakage from these beams yields transients with flux densities of Jy and durations of tens of seconds at 100 pc. Because most travel within a planetary system would be conducted between the habitable worlds within that system, multiply transiting exoplanetary systems offer the greatest chance of detection, especially when the planets are in projected conjunction as viewed from Earth. If interplanetary travel via beam-driven light sails is commonly employed in our galaxy, this activity could be revealed by radio follow-up of nearby transiting exoplanetary systems. The expected signal properties define a new strategy in the search for extraterrestrial intelligence (SETI).

  15. SETI VIA LEAKAGE FROM LIGHT SAILS IN EXOPLANETARY SYSTEMS

    International Nuclear Information System (INIS)

    Guillochon, James; Loeb, Abraham

    2015-01-01

    The primary challenge of rocket propulsion is the burden of needing to accelerate the spacecraft’s own fuel, resulting in only a logarithmic gain in maximum speed as propellant is added to the spacecraft. Light sails offer an attractive alternative in which fuel is not carried by the spacecraft, with acceleration being provided by an external source of light. By artificially illuminating the spacecraft with beamed radiation, speeds are only limited by the area of the sail, heat resistance of its material, and power use of the accelerating apparatus. In this paper, we show that leakage from a light sail propulsion apparatus in operation around a solar system analogue would be detectable. To demonstrate this, we model the launch and arrival of a microwave beam-driven light sail constructed for transit between planets in orbit around a single star, and find an optimal beam frequency on the order of tens of GHz. Leakage from these beams yields transients with flux densities of Jy and durations of tens of seconds at 100 pc. Because most travel within a planetary system would be conducted between the habitable worlds within that system, multiply transiting exoplanetary systems offer the greatest chance of detection, especially when the planets are in projected conjunction as viewed from Earth. If interplanetary travel via beam-driven light sails is commonly employed in our galaxy, this activity could be revealed by radio follow-up of nearby transiting exoplanetary systems. The expected signal properties define a new strategy in the search for extraterrestrial intelligence (SETI)

  16. Update on DOE Advanced IGCC/H2 Gas Turbine

    Science.gov (United States)

    Chupp, Ray

    2009-01-01

    Cooling Flow Reduction: a) Focus on improving turbine hot gas path part cooling efficiency. b) Applicable to current metallic turbine components and synergistic with advanced materials. c) Address challenges of IGCC/hydrogen fuel environment (for example, possible cooling hole plugging). Leakage Flow Reduction: a) Focus on decreasing turbine parasitic leakages, i.e. between static-to-static, static-to-rotating turbine parts. b) Develop improved seal designs in a variety of important areas. Purge Flow Reduction: a) Focus on decreasing required flows to keep rotor disk cavities within temperature limits. b) Develop improved sealing at the cavity rims and modified flow geometries to minimize hot gas ingestion and aerodynamic impact.

  17. Controlled CO2 injection into a shallow aquifer and leakage detection monitoring practices at the K-COSEM site, Korea

    Science.gov (United States)

    Lee, S. S.; Joun, W.; Ju, Y. J.; Ha, S. W.; Jun, S. C.; Lee, K. K.

    2017-12-01

    Artificial carbon dioxide injection into a shallow aquifer system was performed with two injection types imitating short- and long-term CO2 leakage events into a shallow aquifer. One is pulse type leakage of CO2 (6 hours) under a natural hydraulic gradient (0.02) and the other is long-term continuous injection (30 days) under a forced hydraulic gradient (0.2). Injection and monitoring tests were performed at the K-COSEM site in Eumseong, Korea where a specially designed well field had been installed for artificial CO2 release tests. CO2-infused and tracer gases dissolved groundwater was injected through a well below groundwater table and monitoring were conducted in both saturated and unsaturated zones. Real-time monitoring data on CO2 concentration and hydrochemical parameters, and periodical measurements of several gas tracers (He, Ar, Kr, SF6) were obtained. The pulse type short-term injection test was carried out prior to the long-term injection test. Results of the short-term injection test, under natural hydraulic gradient, showed that CO2 plume migrated along the preferential pathway identified through hydraulic interference tests. On the other hand, results of the long-term injection test indicated the CO2 plume migration path was aligned to the forced hydraulic gradient. Compared to the short-term test, the long-term injection formed detectable CO2 concentration change in unsaturated wellbores. Recovery data of tracer gases made breakthrough curves compatible to numerical simulation results. The monitoring results indicated that detection of CO2 leakage into groundwater was more effectively performed by using a pumping and monitoring method in order to capture by-passing plume. With this concept, an effective real-time monitoring method was proposed. Acknowledgement: Financial support was provided by the "R&D Project on Environmental Management of Geologic CO2storage" from the KEITI (Project number : 2014001810003)

  18. Heat Pipe Heat Exchangers with Double Isolation Layers for Prevention of Interpath Leakage Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Current manned spacecraft heat rejection systems use two heat exchangers and an intermediate fluid loop to provide isolation between the crew compartment air and the...

  19. Heat Pipe Heat Exchangers with Double Isolation Layers for Prevention of Interpath Leakage, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Advanced Cooling Technologies, Inc. (ACT), supported by Hamilton Sundstrand, proposes to develop a heat pipe heat exchanger that is low mass and provides two levels...

  20. Suture Technique to Prevent Air Leakage during Negative-Pressure Wound Therapy in Fournier Gangrene

    Directory of Open Access Journals (Sweden)

    Feng-Shu Chang, MD

    2018-01-01

    Conclusions:. The present results suggest that partial wound-edge closure and in situ GranuFoam fixation improve the NPWT leaks in Fournier gangrene wounds. Furthermore, this method is simple to learn and can be useful in applying NPWT to anatomically difficult areas.

  1. Suture Technique to Prevent Air Leakage during Negative-Pressure Wound Therapy in Fournier Gangrene.

    Science.gov (United States)

    Chang, Feng-Shu; Chou, Chieh; Hu, Chuan-Yu; Huang, Shu-Hung

    2018-01-01

    The use of negative-pressure wound therapy (NPWT) for Fournier gangrene management is well documented; however, it is difficult to fixate GranuFoam dressings and maintain an airtight seal over the perineum area. We developed a simple method to facilitate GranuFoam fixation and improve airtight sealing. The Fournier's gangrene severity index (FGSI) score less than 9 was collected in from January 2015 to October 2016. All 13 patients underwent fasciotomy, and NPWT was applied directly on fasciotomy wounds after the debridement of infected tissue. Partial wound closure was performed, and a portion of GranuFoam was inserted to facilitate fixation. The seal check was converted to a 0-10 scale score that was recorded every 4 hours during NPWT. Patient profiles including medical history, FGSI, method of wound closure, and length of stay were collected in this study. The median age of the patients was 62 (38-76) years. The mean FGSI score was 4.3 ± 3.1. The average duration of NPWT was 17.5 ± 11.5 days, and the average seal check score was 0.8 ± 0.5. No seal check alarms were noted during the study. Successful wound closure was achieved in all patients without using additional reconstruction methods such as skin grafting or muscle flap coverage. The present results suggest that partial wound-edge closure and in situ GranuFoam fixation improve the NPWT leaks in Fournier gangrene wounds. Furthermore, this method is simple to learn and can be useful in applying NPWT to anatomically difficult areas.

  2. Two investigations concerning the release of tritium. I. Tritium leakage from 3H(Sc) EC-detectors

    International Nuclear Information System (INIS)

    Bergman, C.; Wesslen, E.

    1977-01-01

    Recently the manufacturers of EC-detectors for gas chromatographs introduced a new type of 3 H EC-detector where the tritium is bound to scandium instead of to titanium and has an activity up to 1 Ci. It is expected that the scandium-based detector will take a great part of the Swedish EC-detector market. The Swedish National Institute of Radiation Protection is anxious to make sure that the introduction of the new detector, which will be used at higher temperature, will not give rise to any increased risk of tritium intake to the personnel handling the chromatographs. The leakage of tritium from commercially available 3 H(Sc) EC-detectors containing 1 Ci of tritium was measured as a function of the detector temperature. Tritium appears both in the form of tritium gas dissolved in the scandium and in the form of tritide. The gas evaporates rather easily with increasing temperature while the dissociation of the tritide is a slower process. The evaporation of tritium due to the dissociation of the tritide was found to be negligible, less than 0.2 μCi/h at temperatures less than 100 0 C, but rises rapidly with temperature. The study also showed that even when the detector is stored at room temperature, a re-distribution of the tritium occures, from the tritide to the dissolved tritium gas, which then easily evaporates even at moderately elevated temperatures

  3. A Proposed Scalable Design and Simulation of Wireless Sensor Network-Based Long-Distance Water Pipeline Leakage Monitoring System

    Directory of Open Access Journals (Sweden)

    Abdulaziz S. Almazyad

    2014-02-01

    Full Text Available Anomalies such as leakage and bursts in water pipelines have severe consequences for the environment and the economy. To ensure the reliability of water pipelines, they must be monitored effectively. Wireless Sensor Networks (WSNs have emerged as an effective technology for monitoring critical infrastructure such as water, oil and gas pipelines. In this paper, we present a scalable design and simulation of a water pipeline leakage monitoring system using Radio Frequency IDentification (RFID and WSN technology. The proposed design targets long-distance aboveground water pipelines that have special considerations for maintenance, energy consumption and cost. The design is based on deploying a group of mobile wireless sensor nodes inside the pipeline and allowing them to work cooperatively according to a prescheduled order. Under this mechanism, only one node is active at a time, while the other nodes are sleeping. The node whose turn is next wakes up according to one of three wakeup techniques: location-based, time-based and interrupt-driven. In this paper, mathematical models are derived for each technique to estimate the corresponding energy consumption and memory size requirements. The proposed equations are analyzed and the results are validated using simulation.

  4. A conservation planning approach to mitigate the impacts of leakage from protected area networks.

    Science.gov (United States)

    Bode, Michael; Tulloch, Ayesha I T; Mills, Morena; Venter, Oscar; Ando, Amy W

    2015-06-01

    Protected area networks are designed to restrict anthropogenic pressures in areas of high biodiversity. Resource users respond by seeking to replace some or all of the lost resources from locations elsewhere in the landscape. Protected area networks thereby perturb the pattern of human pressures by displacing extractive effort from within protected areas into the broader landscape, a process known as leakage. The negative effects of leakage on conservation outcomes have been empirically documented and modeled using homogeneous descriptions of conservation landscapes. Human resource use and biodiversity vary greatly in space, however, and a theory of leakage must describe how this heterogeneity affects the magnitude, pattern, and biodiversity impacts of leakage. We combined models of household utility, adaptive human foraging, and biodiversity conservation to provide a bioeconomic model of leakage that accounts for spatial heterogeneity. Leakage had strong and divergent impacts on the performance of protected area networks, undermining biodiversity benefits but mitigating the negative impacts on local resource users. When leakage was present, our model showed that poorly designed protected area networks resulted in a substantial net loss of biodiversity. However, the effects of leakage can be mitigated if they are incorporated ex-ante into the conservation planning process. If protected areas are coupled with nonreserve policy instruments such as market subsidies, our model shows that the trade-offs between biodiversity and human well-being can be further and more directly reduced. © 2014 Society for Conservation Biology.

  5. Risk factors for leakage following intestinal anastomosis in dogs and cats: 115 cases (1991-2000).

    Science.gov (United States)

    Ralphs, S Christopher; Jessen, Carl R; Lipowitz, Alan J

    2003-07-01

    To identify factors associated with leakage following intestinal anastomosis in dogs and cats. Retrospective study. 90 dogs and 25 cats. Medical records of all dogs and cats that underwent intestinal resection and anastomosis between 1991 and 2000 were reviewed, and information on 27 factors was recorded. Anastomotic leakage was identified in 13 of the 90 dogs but in none of the 25 cats. Preoperative factors significantly associated with development of anastomotic leakage in dogs included preoperative peritonitis, serum albumin concentration, a left shift, and indication for surgery (dogs with intestinal foreign bodies were more likely to have leakage than dogs that underwent surgery for any other cause). Postoperative and case management factors significantly associated with development of leakage included duration of hospitalization, supplemental alimentation, whether the dog ate the day after surgery, blood product administration, and outcome (died vs survived). Discriminant analysis was performed, and dogs with 2 or more of the following factors were predicted to develop anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration dogs. Results suggest that a variety of factors may be associated with development of intestinal anastomotic leakage in dogs. In particular, dogs with 2 or more of the following risk factors are predicted to be at high risk for developing anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration < or = 2.5 g/dL.

  6. Quantification of leakage from large unilamellar lipid vesicles by fluorescence correlation spectroscopy

    DEFF Research Database (Denmark)

    Kristensen, Kasper; Henriksen, Jonas Rosager; Andresen, Thomas Lars

    2014-01-01

    that mastoparan X forms transient transmembrane pores in POPC/POPG (3:1) vesicles, resulting in size-dependent leakage of molecules from the vesicles. We conclude the paper by discussing some of the advantages and limitations of FCS as compared to other existing methods to measure leakage from large unilamellar...

  7. Neutron leakage from Pb and Bc spherical shells with 14 MeV central neutron source

    International Nuclear Information System (INIS)

    Antonov, S.; Daskalov, G.; Ilieva, K.; Jordanova, J.; Prodanova, R.; Zagryadskij, V.A.; Novikov, V.M.; Chuvilin, D.Yu.

    1988-01-01

    Results of measuring neutron leakage from spherical shells of different thickness, made of Pb and Be with a point neutron source in the sphere centrum are presented. The experiment results are compared to calculations according to different programs using data of various nuclear data libraies. The comparison has shown that all the calculations understate the neutron leakage from Pb assmebly. 9 refs.; 2 tabs

  8. The Dutch multicenter experience of the Endo-Sponge treatment for anastomotic leakage after colorectal surgery

    NARCIS (Netherlands)

    van Koperen, P. J.; van Berge Henegouwen, M. I.; Rosman, C.; Bakker, C. M.; Heres, P.; Slors, J. F. M.; Bemelman, W. A.

    2009-01-01

    Anastomotic leakage is a feared complication following colorectal surgery and is associated with early and long-term morbidity and mortality. The presacral cavity as the result of leakage can be treated with an endo-sponge (B-Braun Medical). The aim of this study was to assess the effectiveness of

  9. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  10. Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; He, Ran; Jian, Jiamin

    2016-01-01

    Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism...

  11. Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vlastos, A.E. [Chalmers Univ. of Technology, Gothenburg (Sweden); Orbeck, T. [Sediver Inc., York, SC (United States)

    1996-04-01

    The behavior of the polymeric insulators under salt-storm conditions is crucial for their design. In this paper the leakage currents monitored on silicone composite insulators during two severe salt-storms on the Swedish West Coast are analyzed. The results show that reduction of the leakage distance on silicone rubber units causes considerable dry-band arc activity.

  12. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  13. Horizontal H 2-air turbulent buoyant jet resulting from hydrogen leakage

    KAUST Repository

    El-Amin, Mohamed

    2012-02-01

    The current article is devoted to introducing mathematical and physical analyses with numerical investigation of a buoyant jet resulting from hydrogen leakage in air from a horizontal round source. H 2-air jet is an example of the non-Boussinesq buoyant jet in which a low-density gas jet is injected/leak into a high-density ambient. The density of the mixture is a function of the concentration only, the binary gas mixture is assumed to be of a linear mixing type and the rate of entrainment is assumed to be a function of the plume centerline velocity and the ratio of the mean plume and ambient densities. On the other hand, the local rate of entrainment consists of two components; one is the component of entrainment due to jet momentum while the other is the component of entrainment due to buoyancy. The top-hat profile assumption is used to obtain the mean centerline velocity, width, density and concentration of the H 2-air horizontal jet in addition to kinematic relations which govern the jet trajectories. A set of ordinary differential equations is obtained and solved numerically using Runge-Kutta method. In the second step, the mean axial velocity, mean concentration and mean density of the jet are obtained based on Gaussian model. Finally, several quantities of interest, including the cross-stream velocity, Reynolds stress, velocity-concentration correlation (radial flux), turbulent eddy viscosity and turbulent eddy diffusivity, are obtained by solving the governing partial differential equations. Additionally, the turbulent Schmidt number is estimated and the normalized jet-feed material density and the normalized momentum flux density are correlated. © 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

  14. Assessment of Coronal Leakage of Temporary Restorations in Root Canal-treated Teeth: An in vitro Study.

    Science.gov (United States)

    Srivastava, Pankaj K; Nagpal, Ajay; Setya, Gaurav; Kumar, Sunil; Chaudhary, Alankrita; Dhanker, Kuldeep

    2017-02-01

    Coronal leakage is one of the constant concerns in routine dental practice. It is one of the factors responsible for the failure of root canal therapy. Permanent restorations should be given as soon as possible after the completion of root canal therapy. If unavoidable, provisional restoration should be given in such a way that it maximally reduced the leakage of microorganisms and fluids from the external environment into the canal space. Hence, we evaluated the effect of saliva on the coronal leakage of temporary restorations. Biomechanical preparation of the root canals of 204 fresh mandibular first premolar teeth was done using endodontic files with intermittent irrigation of sodium hypochlorite solution and ethylenediaminetetraacetic acid. Alternate irrigation with normal saline was done periodically. After preparation, drying of the canals was done using paper points followed by sealing of the apical foramen. For the assessment of the microleakage, Siqueira et al apparatus and method was used. All the specimens were divided into four groups based on the provisional restorative material used. All the groups were further divided into three subgroups based on the presence and absence of intracanal medicaments. Verissimo et al's criteria were used to check the turbidity at 1-, 2-, 3-, and 4-week interval respectively. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Chi-square test was used to measure the level of significance, and p provisional restoration showed nonsignificant alterations. Statistically significant alterations were seen at 1, 2, and 3 weeks' interval in all the subgroups except for one with intracanal medicaments. All the temporary restorative materials were not able to prevent microleakage after 1 week's time, with worst bacterial resistance shown by Ketac Molar and ionomer restorative material. Future studies are advocated for better prognosis of root canal therapy.

  15. Gas venting system

    Science.gov (United States)

    Khan, Amjad; Dreier, Ken Wayne; Moulthrop, Lawrence Clinton; White, Erik James

    2010-06-29

    A system to vent a moist gas stream is disclosed. The system includes an enclosure and an electrochemical cell disposed within the enclosure, the electrochemical cell productive of the moist gas stream. A first vent is in fluid communication with the electrochemical cell for venting the moist gas stream to an exterior of the enclosure, and a second vent is in fluid communication with an interior of the enclosure and in thermal communication with the first vent for discharging heated air to the exterior of the enclosure. At least a portion of the discharging heated air is for preventing freezing of the moist gas stream within the first vent.

  16. Feasibility study on rehabilitation and optimization of gas pipeline network/system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of reducing greenhouse effect gas emissions, a survey was conducted on repairs and optimization of gas pipeline net/system in Bangladesh. In the survey, the measurement of methane gas concentration, wind direction/velocity and temperature was made for 16 stations of BC pipeline and BD pipeline including Ring Line. As a result of the measurement, the amount of methane leakage totaled 5,300 tons/year including 1,300 tons in BD pipeline, 2,500 tons in BC pipeline and 1,500 tons in Ring Line. For repairs/optimization of the pipeline net/system, the necessity of the following was pointed out: exchanges of gaskets, piping and valves; repairs of portions of the pipeline exposure; exchanges of pressure control valves and flowmeters; repair of the corrosion prevention system. In this improvement project, the reduction amount of greenhouse effect gas emissions will be 5,300 tons/year and approximately 106,000 tons in 20 years. The conservation will amount to 0.66 MMUS$/year. (NEDO)

  17. Study on detecting leachate leakage of municipal solid waste landfill site.

    Science.gov (United States)

    Liu, Jiangang; Cao, Xianxian; Ai, Yingbo; Zhou, Dongdong; Han, Qiting

    2015-06-01

    The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7. © The Author(s) 2015.

  18. An efficient design to reduce the flux leakage of a spindle motor

    Science.gov (United States)

    Ying, T. F.; Chen, C. M.; Liao, C. P.; Wu, M. D.; Huang, D. R.

    1996-04-01

    A small dc brushless spindle motor with small magnetic flux leakage must be used for a CD-ROM drive application because the magnetic flux leakage may affect the magnetic and electric control circuit of the pickup head. This paper presents a motor design that efficiently reduces magnetic flux leakage by using a pair of yokes on the rotor magnet. Using these yokes at a distance of 2.0 mm reduced the magnetic flux leakage from 344 to 29 G along the radial direction and from 117 to 10 G along the axial direction. After shielding for the magnetic flux leakage, the dynamic performance of the motor cannot be affected. The torque of the CD-ROM spindle motor can be controlled at the same range for shielded and unshielded spindle motors.

  19. Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

  20. Modeling the leakage of LCD displays with local backlight for quality assessment

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.

    2014-01-01

    The recent technique of local backlight dimming has a significant impact on the quality of images displayed with a LCD screen with LED local dimming. Therefore it represents a necessary step in the quality assessment chain, independently from the other processes applied to images. This paper...... investigates the modeling of one of the major spatial artifacts produced by local dimming: leakage. Leakage appears in dark areas when the backlight level is too high for LC cells to block sufficiently and the final displayed brightness is higher than it should. A subjective quality experiment was run...... on videos displayed on LCD TV with local backlight dimming viewed from a 0° and 15° angles. The subjective results are then compared objective data using different leakage models: constant over the whole display or horizontally varying and three leakage factor (no leakage, measured at 0° and 15...

  1. Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Joh, Jeffrey [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-08-01

    LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximately 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.

  2. Anastomotic leakage after esophageal resection: new treatment options by endoluminal vacuum therapy.

    Science.gov (United States)

    Weidenhagen, Rolf; Hartl, Wolfgang H; Gruetzner, Klaus U; Eichhorn, Martin E; Spelsberg, Fritz; Jauch, Karl W

    2010-11-01

    Anastomotic leakage after esophagectomy is an important determinant of early and late morbidity and mortality. Control of the septic focus is essential when treating patients with anastomotic leakages. Surgical and endoscopic treatment options are limited. Between 2005 and 2009, we treated 6 patients who experienced an intrathoracic anastomotic leakage after esophageal resection. After all established therapeutic measures had failed, we explored the feasibility of an endoscopically assisted mediastinal vacuum therapy. We were able to heal intrathoracic esophageal leakages in all 6 patients without any local complications and without the need for reoperation. One patient died because of a progressive pneumonia. Endoscopic vacuum-assisted closure of anastomotic leakages may help to overcome the limitations that are associated with intermittent endoscopic treatment and conventional drainage therapy. Our preliminary results suggest that this new concept may be suitable for those patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Leakage current analysis of single-phase transformer-less grid-connected PV inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Kerekes, Tamas; Teodorescu, Remus

    2015-01-01

    Transformer-less string PV inverter is getting more and more widely utilized due to its higher efficiency, smaller volume and weight. However, without the galvanic isolation, the leakage current limitation and operation safety became the key issues of transformer-less inverters. This paper...... simplifies the leakage current generation circuit model and presents a leakage current estimation method both in real time and frequency domain. It shows that the leakage current is related to the circuit stray parameters, output filter and common mode voltage. Furthermore, with the proposed analysis method......, the leakage current generation of H-bridge with different modulation methods and HERIC inverter are discussed individually. At last, the presented method has been verified via simulation....

  4. Pad use and patient reported bother from urinary leakage after radical prostatectomy.

    Science.gov (United States)

    Wallerstedt, Anna; Carlsson, Stefan; Nilsson, Andreas E; Johansson, Eva; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2012-01-01

    To better understand clinically significant definitions of urinary incontinence we investigated the relationship between urinary leakage and patient reported bother from urinary leakage. A consecutive series of 1,411 men who underwent radical prostatectomy at Karolinska University Hospital, Stockholm, Sweden, from 2002 to 2006 were invited to complete a study specific questionnaire with questions on pad status, urinary leakage and bother from urinary leakage. Questionnaires were received from 1,179 men with a followup of greater than 1 year (median 2.2). Results showed that even a small amount of urinary leakage resulted in a high risk of urinary bother. Of 775 survivors 46 (6%) reporting 0 pads indicated moderate or much bother compared to 38 of 123 (31%) who reported using a security pad. When comparing the 2 groups, the risk of bother from urinary leakage was more than 5 times higher in the safety pad vs the 0 pad group (RR 5.2, 95% CI 3.5-7.7). As the number of pads increased, we noted a higher bother risk. Cross-tabulation of pad use and urinary leakage revealed wide variation in pad requirements despite the same answer to urinary leakage questions. If the definition of continence is based on pad use, for example safety pads, a certain number of men who report moderate or much bother from urinary leakage will be defined as continent. Our results also show that for each stated rate of urinary leakage men prove to have a major variation in the pad requirement. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Correlating antimicrobial activity and model membrane leakage induced by nylon-3 polymers and detergents.

    Science.gov (United States)

    Hovakeemian, Sara G; Liu, Runhui; Gellman, Samuel H; Heerklotz, Heiko

    2015-09-14

    Most antimicrobial peptides act upon target microorganisms by permeabilizing their membranes. The mode of action is often assessed by vesicle leakage experiments that use model membranes, with the assumption that biological activity correlates with the permeabilization of the lipid bilayer. The current work aims to extend the interpretation of vesicle leakage results and examine the correlation between vesicle leakage and antimicrobial activity. To this end, we used a lifetime-based leakage assay with calcein-loaded vesicles to study the membrane permeabilizing properties of a novel antifungal polymer poly-NM, two of its analogs, and a series of detergents. In conjunction, the biological activities of these compounds against Candida albicans were assessed and correlated with data from vesicle leakage. Poly-NM induces all-or-none leakage in polar yeast lipid vesicles at the polymer's MIC, 3 μg mL(-1). At this and higher concentrations, complete leakage after an initial lag time was observed. Concerted activity tests imply that this polymer acts independently of the detergent octyl glucoside (OG) for both vesicle leakage and activity against C. albicans spheroplasts. In addition, poly-NM was found to have negligible activity against zwitterionic vesicles and red blood cells. Our results provide a consistent, detailed picture of the mode of action of poly-NM: this polymer induces membrane leakage by electrostatic lipid clustering. In contrast, poly-MM:CO, a nylon-3 polymer comprised of both cationic and hydrophobic segments, seems to act by a different mechanism that involves membrane asymmetry stress. Vesicle leakage for this polymer is transient (limited to nylon-3 polymers we examined act via similar mechanisms; it is surprising that their mechanisms are so distinct. Some, but not all mechanisms of vesicle permeabilization allow for antimicrobial activity.

  6. A study on effective system depressurization during a PWR vessel bottom break LOCA with HPI failure and gas inflow prevention. ROSA-V/LSTF test SB-PV-05

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Takeda, Takeshi; Asaka, Hideaki; Nakamura, Hideo

    2006-11-01

    A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility (LSTF) of ROSA-V program to study effects of accident management (AM) measures on core cooling, which are important in case of total failure of high pressure injection (HPI) system during an SBLOCA at a pressurized water reactor (PWR). The LSTF is a full-height and 1/48 volume-scaled facility simulating a 4-loop Westinghouse-type PWR (3423 MWt). The experiment, SB-PV-05, simulated a PWR vessel bottom SBLOCA with a rupture of nine instrument tubes, which is equivalent to 0.18% cold leg break. It is clarified that AM actions with steam generator (SG) depressurization to achieve a primary loop cooling rate at -55 K/h and auxiliary feedwater supply for 30 minutes are effective to avoid core uncovery by actuating the low pressure injection (LPI) system. It is also shown through the comparison with the previous experiment of SB-PV-03 that prevention of non-condensable gas inflow from the accumulator injection system (AIS) is very important to actuate the LPI to achieve adequate core cooling. This report presents experiment results of SB-PV-05 in detail and shows the effects of gas inflow prevention on core cooling through the estimation of primary coolant mass and energy balance in the primary system. (author)

  7. Fabrication of gas impervious edge seal for a bipolar gas distribution assembly for use in a fuel cell

    Science.gov (United States)

    Kaufman, Arthur; Werth, John

    1986-01-01

    A bipolar gas reactant distribution assembly for use in a fuel cell is disclosed, the assembly having a solid edge seal to prevent leakage of gaseous reactants wherein a pair of porous plates are provided with peripheral slits generally parallel to, and spaced apart from two edges of the plate, the slit being filled with a solid, fusible, gas impervious edge sealing compound. The plates are assembled with opposite faces adjacent one another with a layer of a fusible sealant material therebetween the slits in the individual plates being approximately perpendicular to one another. The plates are bonded to each other by the simultaneous application of heat and pressure to cause a redistribution of the sealant into the pores of the adjacent plate surfaces and to cause the edge sealing compound to flow and impregnate the region of the plates adjacent the slits and comingle with the sealant layer material to form a continuous layer of sealant along the edges of the assembled plates.

  8. Releasable activity and maximum permissible leakage rate within a transport cask of Tehran Research Reactor fuel samples

    Directory of Open Access Journals (Sweden)

    Rezaeian Mahdi

    2015-01-01

    Full Text Available Containment of a transport cask during both normal and accident conditions is important to the health and safety of the public and of the operators. Based on IAEA regulations, releasable activity and maximum permissible volumetric leakage rate within the cask containing fuel samples of Tehran Research Reactor enclosed in an irradiated capsule are calculated. The contributions to the total activity from the four sources of gas, volatile, fines, and corrosion products are treated separately. These calculations are necessary to identify an appropriate leak test that must be performed on the cask and the results can be utilized as the source term for dose evaluation in the safety assessment of the cask.

  9. Method of detecting leakage from sealing attached to pressure tube

    International Nuclear Information System (INIS)

    Tomomatsu, Ken-ichi; Hayashi, Ken-ichi.

    1990-01-01

    The present invention provides a detection method for measuring the amount of water leaked from sealings attached to the lower end of a pressure tube. That is, the lower end of the pressure tube is sealed only by a metal sealing. A capturing vessel is placed under the pressure tube for capturing the leaked water dropping from the lower end of the pressure tube and the weight of the leaked water is measured on every capturing vessels to determine the amount of the leaked water. The leakage detection method based on the weight measurement has higher accuracy compared with a conventional volume measuring method using a water level gauge as described below. For example, if the volume of the captured water is 10cc, an error of about 0.1cc is caused by the volume measuring method using the water level gauge, whereas if 10g (10cc) weight of water is measured by using an accurate balance, error is only about 10 -4 g (10 -4 cc). Accordingly, the method of the present invention can measure at an accuracy about 1000 times as high as the conventional method. (I.S.)

  10. Investigation of Underground Hydrocarbon Leakage using Ground Penetrating Radar

    Science.gov (United States)

    Srigutomo, Wahyu; Trimadona; Agustine, Eleonora

    2016-08-01

    Ground Penetrating Radar (GPR) survey was carried out in several petroleum plants to investigate hydrocarbon contamination beneath the surface. The hydrocarbon spills are generally recognized as Light Non-Aqueous Phase Liquids (LNAPL) if the plume of leakage is distributed in the capillary fringe above the water table and as Dense Non-Aqueous Phase Liquids (DNAPL) if it is below the water table. GPR antennas of 200 MHz and 400 MHz were deployed to obtain clear radargrams until 4 m deep. In general, the interpreted radargram sections indicate the presence of surface concrete layer, the compacted silty soill followed by sand layer and the original clayey soil as well as the water table. The presence of hydrocarbon plumes are identified as shadow zones (radar velocity and intensity contrasts) in the radargram that blur the layering pattern with different intensity of reflected signal. Based on our results, the characteristic of the shadow zones in the radargram is controlled by several factors: types of hydrocarbon (fresh or bio-degraded), water moisture in the soil, and clay content which contribute variation in electrical conductivity and dielectric constants of the soil.

  11. Investigation of Underground Hydrocarbon Leakage using Ground Penetrating Radar

    International Nuclear Information System (INIS)

    Srigutomo, Wahyu; Trimadona; Agustine, Eleonora

    2016-01-01

    Ground Penetrating Radar (GPR) survey was carried out in several petroleum plants to investigate hydrocarbon contamination beneath the surface. The hydrocarbon spills are generally recognized as Light Non-Aqueous Phase Liquids (LNAPL) if the plume of leakage is distributed in the capillary fringe above the water table and as Dense Non-Aqueous Phase Liquids (DNAPL) if it is below the water table. GPR antennas of 200 MHz and 400 MHz were deployed to obtain clear radargrams until 4 m deep. In general, the interpreted radargram sections indicate the presence of surface concrete layer, the compacted silty soill followed by sand layer and the original clayey soil as well as the water table. The presence of hydrocarbon plumes are identified as shadow zones (radar velocity and intensity contrasts) in the radargram that blur the layering pattern with different intensity of reflected signal. Based on our results, the characteristic of the shadow zones in the radargram is controlled by several factors: types of hydrocarbon (fresh or bio-degraded), water moisture in the soil, and clay content which contribute variation in electrical conductivity and dielectric constants of the soil. (paper)

  12. The Dangers of Rooting: Data Leakage Detection in Android Applications

    Directory of Open Access Journals (Sweden)

    Luca Casati

    2018-01-01

    Full Text Available Mobile devices are widely spread all over the world, and Android is the most popular operative system in use. According to Kaspersky Lab’s threat statistic (June 2017, many users are tempted to root their mobile devices to get an unrestricted access to the file system, to install different versions of the operating system, to improve performance, and so on. The result is that unintended data leakage flaws may exist. In this paper, we (i analyze the security issues of several applications considered relevant in terms of handling user sensitive information, for example, financial, social, and communication applications, showing that 51.6% of the tested applications suffer at least of an issue and (ii show how an attacker might retrieve a user access token stored inside the device thus exposing users to a possible identity violation. Notice that such a token, and a number of other sensitive information, can be stolen by malicious users through a man-in-the-middle (MITM attack.

  13. Feasibility study of tank leakage mitigation using subsurface barriers

    Energy Technology Data Exchange (ETDEWEB)

    Treat, R.L.; Peters, B.B.; Cameron, R.J.; McCormak, W.D.; Trenkler, T.; Walters, M.F. [Ensearch Environmental, Inc. (United States); Rouse, J.K.; McLaughlin, T.J. [Bovay Northwest, Inc., Richland, WA (United States); Cruse, J.M. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-09-21

    The US Department of Energy (DOE) has established the Tank Waste Remediation System (TWRS) to satisfy manage and dispose of the waste currently stored in the underground storage tanks. The retrieval element of TWRS includes a work scope to develop subsurface impermeable barriers beneath SSTs. The barriers could serve as a means to contain leakage that may result from waste retrieval operations and could also support site closure activities by facilitating cleanup. Three types of subsurface barrier systems have emerged for further consideration: (1) chemical grout, (2) freeze walls, and (3) desiccant, represented in this feasibility study as a circulating air barrier. This report contains analyses of the costs and relative risks associated with combinations retrieval technologies and barrier technologies that from 14 alternatives. Eight of the alternatives include the use of subsurface barriers; the remaining six nonbarrier alternative are included in order to compare the costs, relative risks and other values of retrieval with subsurface barriers. Each alternative includes various combinations of technologies that can impact the risks associated with future contamination of the groundwater beneath the Hanford Site to varying degrees. Other potential risks associated with these alternatives, such as those related to accidents and airborne contamination resulting from retrieval and barrier emplacement operations, are not quantitatively evaluated in this report.

  14. Feasibility study of tank leakage mitigation using subsurface barriers

    International Nuclear Information System (INIS)

    Treat, R.L.; Peters, B.B.; Cameron, R.J.; McCormak, W.D.; Trenkler, T.; Walters, M.F.; Rouse, J.K.; McLaughlin, T.J.; Cruse, J.M.

    1994-01-01

    The US Department of Energy (DOE) has established the Tank Waste Remediation System (TWRS) to satisfy manage and dispose of the waste currently stored in the underground storage tanks. The retrieval element of TWRS includes a work scope to develop subsurface impermeable barriers beneath SSTs. The barriers could serve as a means to contain leakage that may result from waste retrieval operations and could also support site closure activities by facilitating cleanup. Three types of subsurface barrier systems have emerged for further consideration: (1) chemical grout, (2) freeze walls, and (3) desiccant, represented in this feasibility study as a circulating air barrier. This report contains analyses of the costs and relative risks associated with combinations retrieval technologies and barrier technologies that from 14 alternatives. Eight of the alternatives include the use of subsurface barriers; the remaining six nonbarrier alternative are included in order to compare the costs, relative risks and other values of retrieval with subsurface barriers. Each alternative includes various combinations of technologies that can impact the risks associated with future contamination of the groundwater beneath the Hanford Site to varying degrees. Other potential risks associated with these alternatives, such as those related to accidents and airborne contamination resulting from retrieval and barrier emplacement operations, are not quantitatively evaluated in this report

  15. Anastomotic leakage after colorectal surgery: diagnostic accuracy of CT

    Energy Technology Data Exchange (ETDEWEB)

    Kauv, Paul; Benadjaoud, Samir; Boulay-Coletta, Isabelle; Zins, Marc [Fondation Hopital Saint-Joseph, Department of Radiology, Paris (France); Curis, Emmanuel [Universite Paris Descartes, Laboratoire de biomathematiques, Faculte de pharmacie, Paris (France); Loriau, Jerome [Fondation Hopital Saint-Joseph, Department of Digestive Surgery, Paris (France)

    2015-12-15

    To evaluate the diagnostic accuracy of CT in postoperative colorectal anastomotic leakage (AL). Two independent blinded radiologists reviewed 153 CTs performed for suspected AL within 60 days after surgery in 131 consecutive patients, with (n = 58) or without (n = 95) retrograde contrast enema (RCE). Results were compared to original interpretations. The reference standard was reoperation or consensus (a radiologist and a surgeon) regarding clinical, laboratory, radiological, and follow-up data after medical treatment. AL was confirmed in 34/131 patients. For the two reviewers and original interpretation, sensitivity of CT was 82 %, 87 %, and 71 %, respectively; specificity was 84 %, 84 %, and 92 %. RCE significantly increased the positive predictive value (from 40 % to 88 %, P = 0.0009; 41 % to 92 %, P = 0.0016; and 40 % to 100 %, P = 0.0006). Contrast extravasation was the most sensitive (reviewers, 83 % and 83 %) and specific (97 % and 97 %) sign and was significantly associated with AL by univariate analysis (P < 0.0001 and P < 0.0001). By multivariate analysis with recursive partitioning, CT with RCE was accurate to confirm or rule out AL with contrast extravasation. CT with RCE is accurate for diagnosing postoperative colorectal AL. Contrast extravasation is the most reliable sign. RCE should be performed during CT for suspected AL. (orig.)

  16. Characteristics of tip-leakage flow in an axial fan

    Science.gov (United States)

    Park, Keuntae; Choi, Haecheon; Choi, Seokho; Sa, Yongcheol

    2014-11-01

    An axial fan with a shroud generates complicated vortical structures by the interaction of the axial flow with the fan blades and shroud near the blade tips. Large eddy simulation (LES) is performed for flow through a forward-swept axial fan, operating at the design condition of Re = 547,000 based on the radius of blade tip and the tip velocity. A dynamic global model (Lee et al. 2010) is used for a subgrid-scale model, and an immersed boundary method in a non-inertial reference frame (Kim & Choi 2006) is adopted for the present simulation. It is found that two vortical structures are formed near the blade tip: the main tip leakage vortex (TLV) and the auxiliary TLV. The main TLV is initiated near the leading edge, develops downstream, and impinges on the pressure surface of the next blade, where the pressure fluctuations and turbulence intensity become high. On the other hand, the auxiliary TLV is initiated at the aft part of the blade but is relatively weak such that it merges with the main TLV. Supported by the KISTI Supercomputing Center (KSC-2014-C2-014).

  17. Geomechanical Simulation of CO2 Leakage and Cap Rock Remediation

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, Runar [Univ. of Missouri, Rolla, MO (United States); Bai, Baojun [Univ. of Missouri, Rolla, MO (United States); Eckert, Andreas [Univ. of Missouri, Rolla, MO (United States)

    2012-09-30

    CO2 sequestration into porous and permeable brine filled aquifers is seen as one of the most likely near-term solutions for reducing greenhouse gases. Safely storing injected CO2, which is less dense than water, requires trapping the CO2 under an impermeable rock which would act as a seal. One of the concerns with CO2 sequestration is the generation of new fractures or reactivation of existing fractures and faults caused by CO2 injection into the sealing formation. Mitigation strategies must be developed to remediate potentially leaking faults or fractures. This project evaluated potential storage scenarios in the state of Missouri and developed coupled reservoir and geomechanic simulations to identify storage potential and leakage risks. Further, several injectable materials used to seal discontinuities were evaluated under subsurface conditions. The four sealant materials investigated were paraffin wax, silica based gel, polymer based gel, and micro-cement, which all significantly reduced the fracture permeability. However, the micro-cement was the most effective sealing agent and the only sealant able to withstand the large differential pressure caused by CO2 or brine injection and create a strong seal to prevent further fracturing.

  18. Detector module for gas monitor

    International Nuclear Information System (INIS)

    1980-01-01

    The invention relates to radioactive source detector module for use in a gas monitor. It is adapted to contain the source and other detector components to allow sealed coupling of those components with other portions of the gas monitor. It is particularly concerned with the use of radioactive materials used as electron sources in gas monitors. The module is used to detect changes in electron flow caused by partial absorption of the electron capture gas flowing between two electrodes. The assembly includes a gas flow source, a gas receiver and an electronic assembly for receiving a signal from the detector. The radioactive source and electrodes are housed so that they are connected to the gas flow source so as to prevent accidental or undesired disconnection. It is designed so that the detector module may be removed or replaced into the gas monitor assemblies by untrained personnel so as to prevent exposure to the radioactive material. Full details are given. (U.K.)

  19. Effects on the mobility of metals from acidification caused by possible CO₂ leakage from sub-seabed geological formations.

    Science.gov (United States)

    de Orte, Manoela Romanó; Sarmiento, Aguasanta M; Basallote, Maria Dolores; Rodríguez-Romero, Araceli; Riba, Inmaculada; Delvalls, Angel

    2014-02-01

    Carbon dioxide capture and storage (CCS) in submarine geological formations has been proposed as a mitigation measure for the prevention of global warming. However, leakage of CO2 to overlying sediments may occur over time, leading to various effects on ecosystems. Laboratory-scale experiments were performed, involving direct release of carbon dioxide into sediment, inside non-pressurized chambers, in order to provide data on the possible effects of CO2 leakage from geological storage sites on the fate of several metals. Marine sediments from three sites with different levels of contamination were sampled and submitted to acidification by means of CO2 injection. The experiment lasted 10 days and sediment samples were collected at the beginning and end of the experiment and pore water was extracted for metal analysis. The results revealed that mobility of metals from sediment to pore water depends on the site, metal and length of time exposed. Mobilization of the metals Al, Fe, Zn, Co, Pb and Cu increases with acidification, and this response generally increases with time of exposure to CO2 injection. The geochemical model applied suggests that acidification also influences the speciation of metals, transforming metals and metalloids, like As, into species much more toxic to biota. The data obtained from this study will be useful for calculating the potential risk of CCS activities to the marine environment. © 2013.

  20. Convective Leakage Makes Heparin Locking of Central Venous Catheters Ineffective Within Seconds: Experimental Measurements in a Model Superior Vena Cava.

    Science.gov (United States)

    Barbour, Michael C; McGah, Patrick M; Ng, Chin H; Clark, Alicia M; Gow, Kenneth W; Aliseda, Alberto

    2015-01-01

    Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter. This novel mechanism is supported by experimental planar laser-induced fluorescence (PLIF) and particle image velocimetry (PIV) measurements of flow velocity and heparin transport from a CVC placed inside a model SVC inside a pulsatile flow loop. The results predict an initial, fast (<10 s), convection-dominated phase that rapidly depletes the concentration of heparin in the near-tip region, the region of the catheter with side holes. This is followed by a slow, diffusion-limited phase inside the catheter lumen, where the concentration is still high, that is insufficient at replenishing the lost heparin concentration in the near-tip region. The results presented here, which are consistent with previous in vivo estimates of 24 hour leakage rates, predict that the concentration of heparin in the near-tip region is essentially zero for the majority of the interdialytic phase, rendering the heparin locking procedure ineffective.

  1. Microbial leakage of Cavit, IRM, and Temp Bond in post-prepared root canals using two methods of gutta-percha removal: an in vitro study.

    Science.gov (United States)

    Balto, Hanan; Al-Nazhan, Saad; Al-Mansour, Khulood; Al-Otaibi, Moneera; Siddiqu, Yunus

    2005-08-15

    The aim of this study was to evaluate the integrity of the coronal seal of Temp-Bond and compare it to Cavit and IRM after post space preparation using S. faecalis as a microbial tracer. In addition, the affect of two methods of gutta percha removal on the apical seal of root canal fillings was also evaluated. Forty extracted human single rooted teeth were prepared chemomechanically and obturated with gutta percha and AH26 sealer cement using the lateral cold condensation technique to a standardized working length of 15 mm. About 10 mm of the coronal gutta-percha was removed with either Peeso-reamer or a hot plugger. The roots were divided into three experimental groups of 10 roots and a control group. Each experimental group was subdivided equally into two groups of 15 each according to the method of post space preparation. Cavit, IRM, and Temp-Bond were used to seal the access opening. Each root was fixed in a cuvette containing Tryptic Soya Broth which, covered 2 mm of the root apex. Bacterial suspension was introduced through pipette. Fresh bacterial suspension was added every week, and the system was monitored daily for the growth of microorganisms for a period of one month. The results showed there was no significant difference in terms of coronal leakage between the three coronal materials used (P=0.478), but the methods of gutta-percha removal did have an impact on the apical leakage (P=0.047). The mean value showed the Peeso-reamer provided less leakage compared to using a hot plugger during the 30-day experimental time period. It was concluded the temporary type of coronal seal of endodontically treated teeth will not prevent coronal leakage if left for a long period of time. In addition, permanent cementation of the post with the coronal restoration should be carried out as soon as possible to prevent recontamination of the root canal.

  2. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  3. Impact of leakage delay on bifurcation in high-order fractional BAM neural networks.

    Science.gov (United States)

    Huang, Chengdai; Cao, Jinde

    2018-02-01

    The effects of leakage delay on the dynamics of neural networks with integer-order have lately been received considerable attention. It has been confirmed that fractional neural networks more appropriately uncover the dynamical properties of neural networks, but the results of fractional neural networks with leakage delay are relatively few. This paper primarily concentrates on the issue of bifurcation for high-order fractional bidirectional associative memory(BAM) neural networks involving leakage delay. The first attempt is made to tackle the stability and bifurcation of high-order fractional BAM neural networks with time delay in leakage terms in this paper. The conditions for the appearance of bifurcation for the proposed systems with leakage delay are firstly established by adopting time delay as a bifurcation parameter. Then, the bifurcation criteria of such system without leakage delay are successfully acquired. Comparative analysis wondrously detects that the stability performance of the proposed high-order fractional neural networks is critically weakened by leakage delay, they cannot be overlooked. Numerical examples are ultimately exhibited to attest the efficiency of the theoretical results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Leakage and sweet spots in triple-quantum-dot spin qubits: A molecular-orbital study

    Science.gov (United States)

    Zhang, Chengxian; Yang, Xu-Chen; Wang, Xin

    2018-04-01

    A triple-quantum-dot system can be operated as either an exchange-only qubit or a resonant-exchange qubit. While it is generally believed that the decisive advantage of the resonant-exchange qubit is the suppression of charge noise because it is operated at a sweet spot, we show that the leakage is also an important factor. Through molecular-orbital-theoretic calculations, we show that when the system is operated in the exchange-only scheme, the leakage to states with double electron occupancy in quantum dots is severe when rotations around the axis 120∘ from z ̂ is performed. While this leakage can be reduced by either shrinking the dots or separating them further, the exchange interactions are also suppressed at the same time, making the gate operations unfavorably slow. When the system is operated as a resonant-exchange qubit, the leakage is three to five orders of magnitude smaller. We have also calculated the optimal detuning point which minimizes the leakage for the resonant-exchange qubit, and have found that although it does not coincide with the double sweet spot for the charge noise, they are rather close. Our results suggest that the resonant-exchange qubit has another advantage, that leakage can be greatly suppressed compared to the exchange-only qubit, and operating at the double sweet spot point should be optimal both for reducing charge noise and suppressing leakage.

  5. Evaluation of the effects of enameloplasty and air abrasion on sealant micro-leakage.

    Directory of Open Access Journals (Sweden)

    Aliasghar Soleymani

    2014-12-01

    Full Text Available Micro-leakage, one of the major reasons for recurrent decays, may lead to uncontrollable flow of liquids, pulp inflammation and peri-apical pathology. The purpose of this in vitro study was to evaluate micro-leakage of pit and fissure sealants after using three different pit and fissure preparation techniques: 1 acid etching, 2 fissure enameloplasty and acid etching, and 3 air abrasion and acid etching.Sixty-nine extracted sound molars and premolars were randomly divided into three groups (23 samples in each group. Teeth were prepared using one of three occlusal surface treatments. Then the sealant was applied on the occlusal fissures of all teeth. The teeth were thermocycled and stored in normal saline. All teeth were sealed apically and coated with nail varnish and then were immersed in a 2% solution of methylen blue. Two buccolingual sections were made. The surfaces were scored 0 to 3 for the extent of micro-leakage using a stereomicroscope. Data were analyzed by Kruskal- wallis and Dunn procedure.Enameloplasty and acid etching were significantly different regarding micro-leakage (P= 0.016, but no significant difference in micro-leakage was observed between air abrasion and the other methods.Enameloplasty followed by acid etching produced significantly less micro-leakage than the acid etching technique. Air abrasion acid etching was better than the acid etching technique in reducing micro-leakage too.

  6. Gate Leakage Reduction by Clocked Power Supply of Adiabatic Logic Circuits

    Directory of Open Access Journals (Sweden)

    Ph. Teichmann

    2005-01-01

    Full Text Available Losses due to gate-leakage-currents become more dominant in new technologies as gate leakage currents increase exponentially with decreasing gate oxide thickness. The most promising Adiabatic Logic (AL families use a clocked power supply with four states. Hence, the full VDD voltage drops over an AL gate only for a quarter of the clock cycle, causing a full gate leakage only for a quarter of the clock period. The rising and falling ramps of the clocked power supply lead to an additional energy consumption by gate leakage. This energy is smaller than the fraction caused by the constant VDD drop, because the gate leakage exponentially depends on the voltage across the oxide. To obtain smaller energy consumption, Improved Adiabatic Logic (IAL has been introduced. IAL swaps all n- and p-channel transistors. The logic blocks are built of p-channel devices which show gate tunneling currents significantly smaller than in n-channel devices. Using IAL instead of conventional AL allows an additional reduction of the energy consumption caused by gate leakage. Simulations based on a 90nm CMOS process show a lowering in gate leakage energy consumption for AL by a factor of 1.5 compared to static CMOS. For IAL the factor is up to 4. The achievable reduction varies depending on the considered AL family and the complexity of the gate.

  7. Study tube housing leakage of 111 conventional diagnostic X-ray machines using ion chamber survey meter

    International Nuclear Information System (INIS)

    Lalrinmawia, Jonathan; Tiwari, Ramesh Chandra; Pau, Kham Suan

    2018-01-01

    This study aims at measuring the leakage radiation from X-ray tube and compare to national and international safety standard. The leakage radiation is formed at the anode inside the X-ray tube and transmitted through the tube housing. The tube housing is proposed to protect both patients and workers from leakage radiation. To the best of the authors' knowledge, no tube housing leakage measurements have been done so far in the present study area

  8. A compact 133Xe gas dispenser

    International Nuclear Information System (INIS)

    Hawkins, T.; Harris, R.

    1977-01-01

    A dispenser for 133 Xe gas is described which is compact and simple to use, allowing the xenon to be dispensed from it shipping ampoule to suitable multi-dose injection vials in a controlled manner and with a high degree of operator safety. The apparatus has no joints and only a single rubber teat, minimizing the risks of adsorption and leakage. A scaled drawing of the dispenser is shown. (U.K.)

  9. Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary - results from VERTOS II

    Energy Technology Data Exchange (ETDEWEB)

    Venmans, Alexander; Klazen, Caroline A.; Rooij, Willem Jan van; Lohle, Paul N. [St. Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Vries, Jolanda de [St. Elisabeth Ziekenhuis Tilburg, Department of Medical Psychology, Tilburg (Netherlands); Mali, Willem P. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2011-01-15

    During percutaneous vertebroplasty (PV), perivertebral cement leakage frequently occurs. There is some concern that cement deposits may migrate towards the lungs via the veins during follow-up. We used baseline and follow-up computed tomography (CT) to assess the incidence and extend of late cement migration in a large consecutive patient cohort. VERTOS II is a prospective multicenter randomized controlled trial comparing PV with conservative therapy for osteoporotic vertebral compression fractures (OVCFs). Patients assigned to PV had baseline postprocedural CT scans of the treated vertebral bodies. After a mean follow-up of 22 months, 54 of 78 patients (69%) had follow-up CT. CT scans were analyzed and compared for perivertebral venous, discal, and soft tissue leakage. Perivertebral cement leakage occurred in 64 of 80 treated vertebrae (80%; 95% CI, 70% to 87%). All patients remained asymptomatic. Perivertebral venous leakage was present in 56 vertebrae (88%), mostly in the anterior external venous plexus (46 of 56, 82%). Discal leakage occurred in 22 of 64 vertebrae (34%) and soft tissue leakage in two of 64 (4%). Mean injected cement volume in vertebrae with leakage was higher (4.5 versus 3.7 cm{sup 3}, p = 0.04). Follow-up CT scan showed unchanged perivertebral cement leakages without late cement migration. Perivertebral cement leaks during PV for OVCFs occurred frequently in the VERTOS II trial. Cement leakage occurred more frequently with higher injected volumes. However, all patients remained asymptomatic, and late cement migration during follow-up did not occur. Standard postprocedural CT of the treated vertebral body in PV is not necessary. (orig.)

  10. Evaluation and prevention of the negative matrix effect of terpenoids on pesticides in apples quantification by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Giacinti, Géraldine; Raynaud, Christine; Capblancq, Sophie; Simon, Valérie

    2017-02-03

    The sample matrix can enhance the gas chromatography signal of pesticide residues relative to that obtained with the same concentration of pesticide in solvent. This paper is related to negative matrix effects observed in coupled gas chromatography-mass spectrometry ion trap (GC/MS 2 ) quantification of pesticides in concentrated extracts of apple peel prepared by the Quick Easy Cheap Effective Rugged and Safe (QuEChERS) method. It is focused on the pesticides most frequently used on the apple varieties studied, throughout the crop cycle, right up to harvest, to combat pests and diseases and to improve fruit storage properties. Extracts from the fleshy receptacle (flesh), the epiderm (peel) and fruit of three apple varieties were studied by high-performance thin-layer chromatography hyphenated with UV-vis light detection (HPTLC/UV visible). The peel extracts had high concentrations of triterpenic acids (oleanolic and ursolic acids), reaching 25mgkg -1 , whereas these compounds were not detected in the flesh extracts (negative matrix effects in GC/MS 2 . The differences in the behavior of pesticides with respect to matrix effects can be accounted for by the physicochemical characteristics of the molecules (lone pairs, labile hydrogen, conjugation). The HPTLC/UV visible method developed here for the characterization of QuEChERS extracts acts as a complementary clean-up method, aimed to decrease the negative matrix effects of such extracts. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2016-01-01

    Conclusions: The amount of leakage was more for 18 MV compare to 6 MV The percentage of the leakage for both energies is less than the 5% value which is recommended by protocols. The fluctuation of the MLC leakage reduced by increasing the field size and depth.

  12. Methane leakage during the evolution of petroleum systems in the Western Canada Sedimentary Basin and the Central Graben area of the North Sea

    Science.gov (United States)

    Berbesi, L. A.; di Primio, R.; Anka, Z.; Horsfield, B.

    2012-04-01

    Around 500 to 600 Tg (1 Tg = 1012 g) of methane enter the atmosphere every year, mainly as product of microbial processes and combustion of fossil fuels and burning biomass. The importance of another source, the geologic emissions of methane, is up to now only loosely constrained. In this study, we addressed the potential methane emissions during the geological evolution of the Western Canada sedimentary basin (WCSB), which holds the largest oil sand accumulations in the world, and the Central Graben area of the North Sea. In the case of the WCSB, thermogenic gas generation and leakage at the sediment surface were addressed through 3D petroleum systems modeling. In this basin, the accumulated oil experienced intense biodegradation that resulted in large masses of biogenic methane. We quantified this latter mass though a two-step mass balance approach. Firstly, we estimated the rate of petroleum degradation and the magnitude of petroleum loss. After this, we calculated the mass of biogenic methane generated using a model that assumes hexadecane (C16H34) as representative of the saturated compounds (Zengler et al., 1999). Our 3D model suggests that 90000-150000 Tg of dry gas (mostly methane) could have leaked during the interval from 80 Ma to 60 Ma. Therefore, uniform leakage rates would have been in the order of 10-3-10-2 Tg yr-1. Biogenic methane generation could have taken place at rates of 10-4 to 10-2 Tg yr-1. However, the effective mass of thermogenic and biogenic methane reaching the atmosphere might have been up to 90% lower than calculated here due to methanotrophic consumption in soils (Etiope and Klusman, 2002). We addressed the thermogenic gas generation and leakage in the Central Graben through two different methods. The first is based on a previous 3D petroleum system modeling of the region (Neumann, 2006). The second consisted of calculating the mass of generated petroleum based on source rock extension and properties (Schmoker, 1994), and then

  13. Cumulative Impacts of Energy and Climate Change Policies on Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Varma, A.; Milnes, R.; Miller, K.; Williams, E. [AEA Technology plc, London (United Kingdom); De Bruyn, S.; Brinke, L. [CE Delft, Delft (Netherlands)

    2012-02-15

    Carbon leakage occurs when climate change policy aimed at reducing carbon dioxide emissions in one country leads to an increase in carbon dioxide emissions in a country that is not bound by these policies. Given that climate change is a global issue, carbon leakage impacts upon the effectiveness of climate change policies. This independent study examines the cumulative impact of climate change policies on carbon leakage. The report brings together findings and analysis from a wide range of primary literature in this area and where possible, conclusions relevant to the UK are drawn.

  14. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  15. The Diagnosis of Internal Leakage of Control Valve Based on the Grey Correlation Analysis Method

    Directory of Open Access Journals (Sweden)

    Zheng DING

    2014-07-01

    Full Text Available The valve plays an important part in the industrial automation system. Whether it operates normally or not relates with the quality of the products directly while its faults are relatively common because of bad working conditions. And the internal leakage is one of the common faults. Consequently, this paper sets up the experimental platform to make the valve in different working condition and collect relevant data online. Then, diagnose the internal leakage of the valve by using the grey correlation analysis method. The results show that this method can not only diagnose the internal leakage of valve accurately, but also distinguish fault degree quantitatively.

  16. Radiation Fields Near Buildings in Case of Radionuclide Leakage

    International Nuclear Information System (INIS)

    Deme, S.; Lang, E.; Pazmandi, T.; Sagi, L.; Goricsan, I.; Szepesi, Zs.

    2001-01-01

    Full text: In case of an accident of nuclear facilities radionuclide emission due to leakage the source term is not measurable by usual stack monitors. For determination of the source term ring type detector systems located around nuclear facilities are often used. Such a system requests 15-25 detectors at a distance of 1-3 km. Based on meteorological data the source term can be estimated. In some cases (e.g. in case of complex terrain) such a method does not provide sufficient accuracy or is too expensive. For such cases the detectors of the monitoring system can be located near building emitting radionuclides. For calculation of the response of the detectors the usual Gaussian-plume approximation method is not valid and no any other relatively simple calculations are not known as in the building wake the turbulent dispersion is very complex. The paper deals with experimental determination of contaminant dispersion in the building wake zone. The 1:250 scale model of the Budapest Research Reactor was used at the wind tunnel of the Budapest Technical University. The radionuclide emission through the wall was simulated by oil fog. This fog was illuminated by a plane laser beam and the two dimensional distribution was determined by a digital measuring camera. Taking a set of such pictures the full three-dimensional concentration grid was received. Using these data the ratio of emission and detector response was calculated for gamma-emitters. The same data can be used for determination of dose distribution and for initial dispersion parameters as well. (author)

  17. Natural and industrial analogues for leakage of CO2 from storagereservoirs: identification of features, events, and processes and lessonslearned

    Energy Technology Data Exchange (ETDEWEB)

    Lewicki, Jennifer L.; Birkholzer, Jens; Tsang, Chin-Fu

    2006-02-28

    The injection and storage of anthropogenic CO2 in deepgeologic formations is a potentially feasible strategy to reduce CO2emissions and atmospheric concentrations. While the purpose of geologiccarbon storage is to trap CO2 underground, CO2 could migrate away fromthe storage site into the shallow subsurface and atmosphere if permeablepathways such as well bores or faults are present. Large-magnitudereleases of CO2 have occurred naturally from geologic reservoirs innumerous volcanic, geothermal, and sedimentary basin settings. Carbondioxide and natural gas have also been released from geologic CO2reservoirs and natural gas storage facilities, respectively, due toinfluences such as well defects and injection/withdrawal processes. Thesesystems serve as natural and industrial analogues for the potentialrelease of CO2 from geologic storage reservoirs and provide importantinformation about the key features, events, and processes (FEPs) that areassociated with releases, as well as the health, safety, andenvironmental consequences of releases and mitigation efforts that can beapplied. We describe a range of natural releases of CO2 and industrialreleases of CO2 and natural gas in the context of these characteristics.Based on this analysis, several key conclusions can be drawn, and lessonscan be learned for geologic carbon storage. First, CO2 can bothaccumulate beneath, and be released from, primary and secondaryreservoirs with capping units located at a wide range of depths. Bothprimary and secondary reservoir entrapments for CO2 should therefore bewell characterized at storage sites. Second, many natural releases of CO2have been correlated with a specific event that triggered the release,such as magmatic fluid intrusion or seismic activity. The potential forprocesses that could cause geomechanical damage to sealing cap rocks andtrigger the release of CO2 from a storage reservoir should be evaluated.Third, unsealed fault and fracture zones may act as fast and directconduits

  18. Potential Flue Gas Impurities in Carbon Dioxide Streams Separated from Coal-fired Power Plants

    Science.gov (United States)

    For geological sequestration of CO2 separated from pulverized coal combustion flue gas, it is necessary to adequately evaluate the potential impacts of flue gas impurities on groundwater aquifers in the case of the CO2 leakage from its storage sites. This s...

  19. The Distribution of Natural Fractures Above a Gas Shale: Questions About Whether Deep Fracture Fluid Leaks into Groundwater Outside the Realm of Faulty Borehole Construction

    Science.gov (United States)

    The question is whether this gas leakage is a case of faulty borehole construction or whether this is a case of methane traveling toward the water table along natural pathways, most likely consisting of unhealed faults or fractures

  20. A review of accidents, prevention and mitigation options related to hazardous gases

    International Nuclear Information System (INIS)

    Fthenakis, V.M.

    1993-05-01

    Statistics on industrial accidents are incomplete due to lack of specific criteria on what constitutes a release or accident. In this country, most major industrial accidents were related to explosions and fires of flammable materials, not to releases of chemicals into the environment. The EPA in a study of 6,928 accidental releases of toxic chemicals revealed that accidents at stationary facilities accounted for 75% of the total number of releases, and transportation accidents for the other 25%. About 7% of all reported accidents (468 cases) resulted in 138 deaths and 4,717 injuries ranging from temporary respiratory problems to critical injuries. In-plant accidents accounted for 65% of the casualties. The most efficient strategy to reduce hazards is to choose technologies which do not require the use of large quantities of hazardous gases. For new technologies this approach can be implemented early in development, before large financial resources and efforts are committed to specific options. Once specific materials and options have been selected, strategies to prevent accident initiating events need to be evaluated and implemented. The next step is to implement safety options which suppress a hazard when an accident initiating event occurs. Releases can be prevented or reduced with fail-safe equipment and valves, adequate warning systems and controls to reduce and interrupt gas leakage. If an accident occurs and safety systems fail to contain a hazardous gas release, then engineering control systems will be relied on to reduce/minimize environmental releases. As a final defensive barrier, the prevention of human exposure is needed if a hazardous gas is released, in spite of previous strategies. Prevention of consequences forms the final defensive barrier. Medical facilities close by that can accommodate victims of the worst accident can reduce the consequences of personnel exposure to hazardous gases