WorldWideScience

Sample records for pressure loss coefficient

  1. Preliminary Experimental Study on Pressure Loss Coefficients of Exhaust Manifold Junction

    Directory of Open Access Journals (Sweden)

    Xiao-lu Lu

    2014-01-01

    Full Text Available The flow characteristic of exhaust system has an important impact on inlet boundary of the turbine. In this paper, high speed flow in a diesel exhaust manifold junction was tested and simulated. The pressure loss coefficient of the junction flow was analyzed. The steady experimental results indicated that both of static pressure loss coefficients L13 and L23 first increased and then decreased with the increase of mass flow ratio of lateral branch and public manifold. The total pressure loss coefficient K13 always increased with the increase of mass flow ratio of junctions 1 and 3. The total pressure loss coefficient K23 first increased and then decreased with the increase of mass flow ratio of junctions 2 and 3. These pressure loss coefficients of the exhaust pipe junctions can be used in exhaust flow and turbine inlet boundary conditions analysis. In addition, simulating calculation was conducted to analyze the effect of branch angle on total pressure loss coefficient. According to the calculation results, total pressure loss coefficient was almost the same at low mass flow rate of branch manifold 1 but increased with lateral branch angle at high mass flow rate of branch manifold 1.

  2. Large scale steam flow test: Pressure drop data and calculated pressure loss coefficients

    International Nuclear Information System (INIS)

    Meadows, J.B.; Spears, J.R.; Feder, A.R.; Moore, B.P.; Young, C.E.

    1993-12-01

    This report presents the result of large scale steam flow testing, 3 million to 7 million lbs/hr., conducted at approximate steam qualities of 25, 45, 70 and 100 percent (dry, saturated). It is concluded from the test data that reasonable estimates of piping component pressure loss coefficients for single phase flow in complex piping geometries can be calculated using available engineering literature. This includes the effects of nearby upstream and downstream components, compressibility, and internal obstructions, such as splitters, and ladder rungs on individual piping components. Despite expected uncertainties in the data resulting from the complexity of the piping geometry and two-phase flow, the test data support the conclusion that the predicted dry steam K-factors are accurate and provide useful insight into the effect of entrained liquid on the flow resistance. The K-factors calculated from the wet steam test data were compared to two-phase K-factors based on the Martinelli-Nelson pressure drop correlations. This comparison supports the concept of a two-phase multiplier for estimating the resistance of piping with liquid entrained into the flow. The test data in general appears to be reasonably consistent with the shape of a curve based on the Martinelli-Nelson correlation over the tested range of steam quality

  3. A study on improvement of analytical prediction model for spacer grid pressure loss coefficients

    International Nuclear Information System (INIS)

    Lim, Jonh Seon

    2002-02-01

    Nuclear fuel assemblies used in the nuclear power plants consist of the nuclear fuel rods, the control rod guide tubes, an instrument guide tube, spacer grids,a bottom nozzle, a top nozzle. The spacer grid is the most important component of the fuel assembly components for thermal hydraulic and mechanical design and analyses. The spacer grids fixed with the guide tubes support the fuel rods and have the very important role to activate thermal energy transfer by the coolant mixing caused to the turbulent flow and crossflow in the subchannels. In this paper, the analytical spacer grid pressure loss prediction model has been studied and improved by considering the test section wall to spacer grid gap pressure loss independently and applying the appropriate friction drag coefficient to predict pressure loss more accurately at the low Reynolds number region. The improved analytical model has been verified based on the hydraulic pressure drop test results for the spacer grids of three types with 5x5, 16x16, 17x17 arrays, respectively. The pressure loss coefficients predicted by the improved analytical model are coincident with those test results within ±12%. This result shows that the improved analytical model can be used for research and design change of the nuclear fuel assembly

  4. Basic data generation and pressure loss coefficient evaluation for HANARO core thermal-hydraulic analyses

    International Nuclear Information System (INIS)

    Chae, Hee Taek; Lee, Kye Hong

    1999-06-01

    MATRA-h, a HANARO subchannel analysis computer code, is used to evaluate thermal margin of the HANARO fuel. It's capability includes the assessments of CHF, ONB margin, and fuel temperature. In this report, basic input data and core design parameters required to perform the subchannel analysis with MATRA-h code are collected. These data include the subchannel geometric data, thermal-hydraulic correlations, empirical constants and material properties. The friction and form loss coefficients of the fuel assemblies were determined based on the results of the pressure drop test. At the same time, different form loss coefficients at the end plates and spacers are evaluated for various subchannels. The adequate correlations are applied to the evaluation of the form loss coefficients for various subchannels, which are corrected by measured values in order to have a same pressure drop at each flow channel. These basic input data and design parameters described in this report will be applied usefully to evaluate the thermal margin of the HANARO fuel. (author). 11 refs., 13 tabs., 11 figs

  5. Irrecoverable pressure loss coefficients for two out-of-plane piping elbows at high Reynolds number

    Energy Technology Data Exchange (ETDEWEB)

    Coffield, R.D.; Hammond, R.B.; McKeown, P.T.

    1999-02-08

    Pressure drops of multiple piping elbows were experimentally determined for high Reynolds number flows. The testing described has been performed in order to reduce uncertainties in the currently used methods for predicting irrecoverable pressure losses and also to provide a qualification database for computational fluid dynamics (CFD) computer codes. The earlier high Reynolds number correlations had been based on extrapolations over several orders of magnitude in Reynolds number from where the original database existed. Recent single elbow test data shows about a factor of two lower elbow pressure loss coefficient (at 40x 106 Reynolds number) than those from current correlations. This single piping elbow data has been extended in this study to a multiple elbow configuration of two elbows that are 90o out-of-plane relative to each other. The effects of separation distance and Reynolds number have been correlated and presented in a form that can be used for design application. Contrary to earlier extrapolations from low Reynolds numbers (Re c 1.0x 106), a strong Reynolds number dependence was found to exist. The combination of the high Reynolds number single elbow data with the multiple elbow interaction effects measured in this study shows that earlier design correlations are conservative by significant margins at high Reynolds numbers. Qualification of CFD predictions with this new high Reynolds number database will help guide the need for additional high Reynolds number testing of other piping configurations. The study also included velocity measurements at several positions downstream of the first and second test elbows using an ultrasonic flowmeter. Reasonable agreement after the first test elbow was found relative to flow fields that are known to exist from low Reynolds number visual tests and also from CFD predictions. This data should help to qualify CFD predictions of the three-dimensional flow stream downstream of the second test elbow.

  6. Pressure loss coefficient evaluation based on CFD analysis for simple geometries and PWR reactor vessel without geometry simplification

    International Nuclear Information System (INIS)

    Ko II, B.; Park, J. P.; Jeong, J. H.

    2008-01-01

    Nuclear vendors and utilities perform lots of simulations and analyses in order to ensure the safe operation of nuclear power plants (NPPs). In general, the simulations are carried out using vendor-specific design codes and best-estimate system analysis codes and most of them were developed based on 1-dimensional lumped parameter models. These thermal-hydraulic system analysis codes require user input for pressure loss coefficient, k-factor; since they numerically solve Euler-equation. In spite of its high impact on the safety analysis results, there has not been good validation method for the selection of loss coefficient. During the past decade, however; computers, parallel computation methods, and 3-dimensional computational fluid dynamics (CFD) codes have been dramatically enhanced. It is believed to be beneficial to take advantage of advanced commercial CFD codes in safety analysis and design of NPP5. The present work aims to validate pressure loss coefficient evaluation for simple geometries and k-factor calculation for PWR based on CFD. The performances of standard k-ε model, RNG k-ε model, Reynolds stress model (RSM) on the simulation of pressure drop for simple geometry such as, or sudden-expansion, and sudden-contraction are evaluated. The calculated value was compared with pressure loss coefficient in handbook of hydraulic resistance. Then the present work carried out analysis for flow distribution in downcomer and lower plenum of Korean standard nuclear power plants (KSNPs) using STAR-CD. The lower plenum geometry of a PWR is very complicated since there are so many reactor internals, which hinders in CFD analysis for real reactor geometry up to now. The present work takes advantage of 3D CAD model so that real geometry of lower plenum is used. The results give a clear figure about flow fields in the reactor vessel, which is one of major safety concerns. The calculated pressure drop across downcomer and lower plenum appears to be in good agreement

  7. Effect of the Contact Pressure on the Friction Loss Coefficient in a Micro Gap

    International Nuclear Information System (INIS)

    Nam, Ho Yun; Kim, Jong Man; Kim, Jong Bum; Lee, Yong Bum

    2010-01-01

    As one way to improve the reliability of a steam generator for a sodium-cooled fast reactor, a double-wall tube steam generator is being developed. The current development of the DWTSG focuses on the improvement of heat transfer capability for a double-wall tube and the development of a proper leak detection method for the double-wall tube during the operation of a reactor. In the conventional double wall tubes(DWT), the inner tube and the outer tube are made of the same material. When the temperature difference between the inner tube and the outer tube increases, the heat transfer efficiency decreases. To improve the heat transfer capability of a double wall tube, the inner tube is made of a material with a thermal expansion coefficient which is about 10 to 15% greater than that of the outer tube . For the on-line and real-time detection of whether the heat transfer tube is damaged or not, a detection method was developed by combining the heat transfer tube gaps and the detection holes meeting with a one-to-one correspondence in the lower tubesheet. In the pre-stressed DWT, there is a very small space due to the surface roughness of the inner wall and outer wall. Thus, if the outer wall is broken, the helium gas (2MPa) in the very narrow space is ejected into the sodium (0.1MPa), and if the inner wall is broken, the superheated gas (16.5MPa) is ejected into the space filled with helium gas. If the four grooves with 0.2-04mm depths are dug in the inner surface of the outer wall in order for the helium gas to flow easily, we can detect the leakage by checking the change of gas volume in the online groove

  8. Experiments and correlations of pressure loss coefficients for hexagonal arranged rod bundles (P/D > 1.02) with helical wire spacers in laminar and turbulent flows

    International Nuclear Information System (INIS)

    Marten, K.; Yonekawa, S.; Hoffmann, H.

    1987-05-01

    Advanced pressurized water reactors as well as sodium cooled fast reactors, in their breeding and absorber elements, use tightly packed rod bundles with hexagonally arranged rods. Helical wires or helical fins serve as spacers. The pressure loss coefficients of twelve bundles with helical wires were determined systematically in water experiments. High measuring accuracy was achieved by very precise fabrication of the bundles and the shroud as well as by investigations of the proper measuring techniques. The results show a dependency of the loss coefficients on the Reynolds number and on the P/D and H/D ratios of the bundles. These results together with available systematic experimental results of investigations at P/D > 1.1 were used to develop a correlation to determine the pressure loss coefficients of tightly and widely packed hexagonally arranged rod bundles with helical wire spacers. These correlations were used to recalculate and compare results of pressure loss investigations found in the literature; good agreement was demonstrated. Hence, calculation methods exist for a broad range of applications to determine the pressure loss coefficients of hexagonally arranged rod bundles with helical wires for spacers. (orig./HP) [de

  9. Pressure loss coefficient and flow rate of side hole in a lower end plug for dual-cooled annular nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chang-Hwan, E-mail: shinch@kaeri.re.kr; Park, Ju-Yong, E-mail: juyong@kaeri.re.kr; In, Wang-Kee, E-mail: wkin@kaeri.re.kr

    2013-12-15

    Highlights: • A lower end plug with side flow holes is suggested to provide alternative flow paths of the inner channel. • The inlet loss coefficient of the lower end plug is estimated from the experiment. • The flow rate through the side holes is estimated in a complete entrance blockage of inner channel. • The consequence in the reactor core condition is evaluated with a subchannel analysis code. - Abstract: Dual-cooled annular nuclear fuel for a pressurized water reactor (PWR) has been introduced for a significant increase in reactor power. KAERI has been developing a dual-cooled annular fuel for a power uprate of 20% in an optimized PWR in Korea, the OPR1000. This annular fuel can help decrease the fuel temperature substantially relative to conventional cylindrical fuel at a power uprate. Annular fuel has dual flow channels around itself; however, the inner flow channel has a weakness in that it is isolated unlike the outer flow channel, which is open to other neighbouring outer channels for a coolant exchange in the reactor core. If the entrance of the inner channel is, as a hypothetical event, completely blocked by debris, the inner channel will then experience a rapid increase in coolant temperature such that a departure from nucleate boiling (DNB) may occur. Therefore, a remedy to avoid such a postulated accident is indispensable for the safety of annular fuel. A lower end plug with side flow holes was suggested to provide alternative flow paths in addition to the central entrance of the inner channel. In this paper, the inlet loss coefficient of the lower end plug and the flow rate through the side holes were estimated from the experimental results even in a complete entrance blockage of the inner channel. An optimization for the side hole was also performed, and the results are applied to a subchannel analysis to evaluate the consequence in the reactor core condition.

  10. Analytical prediction of fuel assembly spacer grid loss coefficient

    International Nuclear Information System (INIS)

    Lim, J. S.; Nam, K. I.; Park, S. K.; Kwon, J. T.; Park, W. J.

    2002-01-01

    The analytical prediction model of the fuel assembly spacer grid pressure loss coefficient has been studied. The pressure loss of gap between the test section wall and spacer grid was separated from the current model and the different friction drag coefficient on spacer straps from high Reynolds number region were used to low Reynolds number region. The analytical model has been verified based on the hydraulic pressure drop test results for the spacer grids of three types for 5x5, 16x16(or 17x17) arrays. The analytical model predicts the pressure loss coefficients obtained from test results within the maximum errors of 12% and 7% for 5x5 test bundle and full size bundle, respectively, at Reynolds number 500,000 of the core operating condition. This result shows that the analytical model can be used for research and design change of the nuclear fuel assembly

  11. Probability based calibration of pressure coefficients

    DEFF Research Database (Denmark)

    Hansen, Svend Ole; Pedersen, Marie Louise; Sørensen, John Dalsgaard

    2015-01-01

    Normally, a consistent basis for calculating partial factors focuses on a homogeneous reliability index neither depending on which material the structure is constructed of nor the ratio between the permanent and variable actions acting on the structure. Furthermore, the reliability index should n...... the characteristic shape coefficients are based on mean values as specified in background documents to the Eurocodes. Importance of hidden safeties judging the reliability is discussed for wind actions on low-rise structures....... not depend on the type of variable action. A probability based calibration of pressure coefficients have been carried out using pressure measurements on the standard CAARC building modelled on scale of 1:383. The extreme pressures measured on the CAARC building model in the wind tunnel have been fitted.......3, the Eurocode partial factor of 1.5 for variable actions agrees well with the inherent uncertainties of wind actions when the pressure coefficients are determined using wind tunnel test results. The increased bias and uncertainty when pressure coefficients mainly are based on structural codes lead to a larger...

  12. Pressure drop coefficient of laminar Newtonian flow in axisymmetric diffusers

    International Nuclear Information System (INIS)

    Rosa, S.; Pinho, F.T.

    2006-01-01

    The laminar flow of Newtonian fluids in axisymmetric diffusers has been numerically investigated to evaluate the pressure-loss coefficient as a function of Reynolds number, diffusion angle and expansion ratio. The numerical simulations were carried out with a finite-volume based code using non-orthogonal collocated grids and second order accurate differencing schemes to discretize all terms of the transport equations. The calculations were carried out for Reynolds numbers between 2 and 200, diffusion angles from 0 deg. to 90 deg. and expansion ratios of 1.5 and 2 and the data are presented in tabular form and as correlations. A simplified 1D theoretical analysis helped explain the various contributions to the loss coefficient and its difference relative to the reversible pressure variation due to differences between the actual and fully developed friction losses, distortions of the velocity profiles and pressure non-uniformity upstream and downstream of the expansion section

  13. Pressure drop coefficient of laminar Newtonian flow in axisymmetric diffusers

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, S. [Escola Superior de Tecnologia e Gestao, Instituto Politecnico, Campus de Santa Apolonia, 5301-857 Braganca (Portugal)]. E-mail: srosa@ipb.pt; Pinho, F.T. [Centro de Estudos de Fenomenos de Transporte, DEM, Universidade do Minho, Campus de Azurem, 4800-058 Guimaraes (Portugal)]. E-mail: fpinho@fe.up.pt

    2006-04-15

    The laminar flow of Newtonian fluids in axisymmetric diffusers has been numerically investigated to evaluate the pressure-loss coefficient as a function of Reynolds number, diffusion angle and expansion ratio. The numerical simulations were carried out with a finite-volume based code using non-orthogonal collocated grids and second order accurate differencing schemes to discretize all terms of the transport equations. The calculations were carried out for Reynolds numbers between 2 and 200, diffusion angles from 0 deg. to 90 deg. and expansion ratios of 1.5 and 2 and the data are presented in tabular form and as correlations. A simplified 1D theoretical analysis helped explain the various contributions to the loss coefficient and its difference relative to the reversible pressure variation due to differences between the actual and fully developed friction losses, distortions of the velocity profiles and pressure non-uniformity upstream and downstream of the expansion section.

  14. Measurement and CFD calculation of spacer loss coefficient for a tight-lattice fuel bundle

    International Nuclear Information System (INIS)

    In, Wang Kee; Shin, Chang Hwan; Kwack, Young Kyun; Lee, Chi Young

    2015-01-01

    Highlights: • Experiment and CFD analysis evaluated the pressure drop in a spacer grid. • The measurement and CFD errors for the spacer loss coefficient were estimated. • The spacer loss coefficient for the dual-cooled annular fuel bundle was determined. • The CFD prediction agrees with the measured spacer loss coefficient within 8%. - Abstract: An experiment and computational fluid dynamics (CFD) analysis were performed to evaluate the pressure drop in a spacer grid for a dual-cooled annular fuel (DCAF) bundle. The DCAF bundle for the Korean optimum power reactor (OPR1000) is a 12 × 12 tight-lattice rod array with a pitch-to-diameter ratio of 1.08 owing to a larger outer diameter of the annular fuel rod. An experiment was conducted to measure the pressure drop in spacer grid for the DCAF bundle. The test bundle is a full-size 12 × 12 rod bundle with 11 spacer grid. The test condition covers a Reynolds number range of 2 × 10 4 –2 × 10 5 by changing the temperature and flow rate of water. A CFD analysis was also performed to predict the pressure drop through a spacer grid using the full-size and partial bundle models. The pressure drop and loss coefficient of a spacer grid were predicted and compared with the experimental results. The CFD predictions of spacer pressure drop and loss coefficient agree with the measured values within 8%. The spacer loss coefficient for the DCAF bundle is estimated to be approximately 1.50 at a nominal operating condition of OPR1000, i.e., Re = 4 × 10 5

  15. Minimum wall pressure coefficient of orifice plate energy dissipater

    Directory of Open Access Journals (Sweden)

    Wan-zheng Ai

    2015-01-01

    Full Text Available Orifice plate energy dissipaters have been successfully used in large-scale hydropower projects due to their simple structure, convenient construction procedure, and high energy dissipation ratio. The minimum wall pressure coefficient of an orifice plate can indirectly reflect its cavitation characteristics: the lower the minimum wall pressure coefficient is, the better the ability of the orifice plate to resist cavitation damage is. Thus, it is important to study the minimum wall pressure coefficient of the orifice plate. In this study, this coefficient and related parameters, such as the contraction ratio, defined as the ratio of the orifice plate diameter to the flood-discharging tunnel diameter; the relative thickness, defined as the ratio of the orifice plate thickness to the tunnel diameter; and the Reynolds number of the flow through the orifice plate, were theoretically analyzed, and their relationships were obtained through physical model experiments. It can be concluded that the minimum wall pressure coefficient is mainly dominated by the contraction ratio and relative thickness. The lower the contraction ratio and relative thickness are, the larger the minimum wall pressure coefficient is. The effects of the Reynolds number on the minimum wall pressure coefficient can be neglected when it is larger than 105. An empirical expression was presented to calculate the minimum wall pressure coefficient in this study.

  16. Modified loss coefficients in the determination of optimum generation scheduling

    Energy Technology Data Exchange (ETDEWEB)

    Hazarika, D.; Bordoloi, P.K. (Assam Engineering Coll. (IN))

    1991-03-01

    A modified method has been evolved to form the loss coefficients of an electrical power system network by decoupling load and generation and thereby creating additional fictitious load buses. The system losses are then calculated and co-ordinated to arrive at an optimum scheduling of generation using the standard co-ordination equation. The method presented is superior to the ones currently available, in that it is applicable to a multimachine system with random variation of load and it accounts for limits in plant generations and line losses. The precise nature of results and the economy in the cost of energy production obtained by this method is quantified and presented. (author).

  17. Integral linear momentum balance in combining flows for calculating the pressure drop coefficients

    International Nuclear Information System (INIS)

    Bollmann, A.

    1983-01-01

    Equations for calculating the loss coefficient in combining flows in tee functions are obtained by an integral linear momentum balance. It is a practice, when solving this type of problem, to neglect the pressure difference in the upstream location as well as the wall-fluid interaction in the lateral branch of the junction. In this work it is demonstrated the influence of the above parameters on the loss coefficient based on experimental values and by apropriate algebraic manipulation of the loss coefficient values published by previous investigators. (Author) [pt

  18. Transmission Loss Calculation using A and B Loss Coefficients in Dynamic Economic Dispatch Problem

    Science.gov (United States)

    Jethmalani, C. H. Ram; Dumpa, Poornima; Simon, Sishaj P.; Sundareswaran, K.

    2016-04-01

    This paper analyzes the performance of A-loss coefficients while evaluating transmission losses in a Dynamic Economic Dispatch (DED) Problem. The performance analysis is carried out by comparing the losses computed using nominal A loss coefficients and nominal B loss coefficients in reference with load flow solution obtained by standard Newton-Raphson (NR) method. Density based clustering method based on connected regions with sufficiently high density (DBSCAN) is employed in identifying the best regions of A and B loss coefficients. Based on the results obtained through cluster analysis, a novel approach in improving the accuracy of network loss calculation is proposed. Here, based on the change in per unit load values between the load intervals, loss coefficients are updated for calculating the transmission losses. The proposed algorithm is tested and validated on IEEE 6 bus system, IEEE 14 bus, system IEEE 30 bus system and IEEE 118 bus system. All simulations are carried out using SCILAB 5.4 (www.scilab.org) which is an open source software.

  19. Interpretation of Nonlinear Well Loss Coefficients for Rorabaugh (1953) Method.

    Science.gov (United States)

    Kurtulus, B.; Yaylım, T. N.; Avşar

    2016-12-01

    Step drawdown test (SDT) are essential for hydrogeologist to determine aquifer loss and well loss parameters. In a SDT, different series of constant-discharges with incremental rates are conducted to obtain incremental drawdown into the pumping well. Pumping well efficiency (if the well is properly developed and designed), aquifer characteristics (transmissivity, storativity) and discharge-drawdown relationship can be derived from SDT. The well loss parameter directly associate with the well efficiency. The main problem is to determine the correct well loss parameter in order to estimate aquifer characteristics. Walton (1962) stated that the interpretation of the well efficiency is possible to determine the nonlinear head loss coefficient (C) with p equals to 2 and Walton (1962) presented a criteria that suggested the following terms: If C is less than 1800 m2/s5, the is properly developed and designed, If C is ranged from 1800 m2/s5 to 3600 m2/s5, the well has a mild deterioration, If C is greater than 3600 m2/s5, the well has a severe clogging. Until now, several well-known computer techniques such as Aqutesolv, AquiferWin32 , AquifertestPro can be found in the literature to evaluate well efficiency when exponential parameter (p) equals to 2. However, there exist a lack of information to evaluate well efficiency for different number of exponential parameter (p). Strategic Water Storage & Recovery (SWSR) Project in Liwa, Abu Dhabi is the leading and unique hydrogeology project in the world because of its both financial and scientific dimension. A total of 315 recovery wells have been drilled in pursuance of the scope of the SWSR project. A Universal Well Efficiency Criteria (UWEC) is developed using 315 Step Drawdown Test (SDT). UWEC is defined for different number of head loss equation coefficients. The results reveal that there is a strong correlation between non-linear well loss coefficient (C) and exponential parameter (p) up to a coefficient of determination

  20. Effect of rolling motion on the expansion and contraction loss coefficients

    International Nuclear Information System (INIS)

    Yan, B.H.; Gu, H.Y.

    2013-01-01

    Highlights: ► The expansion and contraction loss coefficients in rolling motion are analyzed. ► Effects of rolling motion on the expansion and contraction loss coefficients are different. ► The spanwise and transverse additional forces contribute slightly to the local loss. ► The oscillations of loss coefficients increase as the strengthening of rolling motion. - Abstract: The sudden expansion and sudden contraction loss coefficients in rolling motion are investigated with CFD code FLUENT. The calculation results are validated with experimental and theoretical results in steady state. The effects of rolling motion on the expansion and contraction loss coefficients are different. The effects of spanwise and transverse additional forces on the expansion and contraction loss coefficients are weak. The effect of velocity oscillation on the contraction loss coefficient is more significant than that on the expansion loss coefficient. The oscillation of local loss coefficient also becomes more and more irregular as the strengthening of rolling motion

  1. Static pressure and temperature coefficients of laboratory standard microphones

    DEFF Research Database (Denmark)

    Rasmussen, Knud

    1996-01-01

    of the microphone. The static pressure and temperature coefficients were determined experimentally for about twenty samples of type BK 4160 and BK 4180 microphones. The results agree almost perfectly with the predictions for BK 4160, while some modifications of the lumped parameter values are called for to make......-order approximation of resonances in the back cavity. It was found that each of the coefficients, for a given type of microphone, can be expressed by a single function when the coefficients are normalized by their low-frequency value and the frequency axis normalized by the individual resonance frequency...

  2. The Yaws handbook of vapor pressure Antoine coefficients

    CERN Document Server

    Yaws, Carl L

    2015-01-01

    Increased to include over 25,000 organic and inorganic compounds, The Yaws Handbook of Vapor Pressure: Antoine Coefficients, 2nd Edition delivers the most comprehensive and practical database source for today's petrochemical. Understanding antoine coefficients for vapor pressure leads to numerous critical engineering applications such as pure components in storage vessels, pressure relief valve design, flammability limits at the refinery, as well as environmental emissions from exposed liquids, making data to efficiently calculate these daily challenges a fundamental need. Written by the world's leading authority on chemical and petrochemical data, The Yaws Handbook of Vapor Pressure simplifies the guesswork for the engineer and reinforces the credibility of the engineer's calculations with a single trust-worthy source. This data book is a must-have for the engineer's library bookshelf. Increase compound coverage from 8,200 to over 25,000 organic and inorganic compounds, including sulfur and hydrocarbons Sol...

  3. Improving MODPRESS heat loss calculations for PWR pressurizers

    International Nuclear Information System (INIS)

    Ramos, Natalia V.; Lira, Carlos A. Brayner O.; Castrillho, Lazara S.

    2009-01-01

    The improvement of heat loss calculations in MODPRESS transient code for PWR pressurizer analysis is the main focus of this investigation. Initially, a heat loss model was built based on heat transfer coefficient (HTC) correlations obtained in handbooks of thermal engineering. A hand calculation for Neptunus experimental test number U47 yielded a thermal power loss of 11.2 kW against 17.3 kW given by MODPRESS at the same conditions, while the experimental estimate is given as 17 kW. This comparison is valid only for steady state or before starting the transient experiment, because MODPRESS does not update HTC's when the transient phase begins. Furthermore, it must be noted that MODPRESS heat transfer coefficients are adjusted to reproduce the experimental value of the specific type of pressurizer. After inserting the new routine for HTC's into MODPRESS, the heat loss was calculated as 11.4 kW, a value very close to the first estimate but far below 17 kW found in the U47 experiment. In this paper, the heat loss model and results will be described. Further research is being developed to find a more general HTC that allows the analysis of the effects of heat losses on transient behavior of Neptunus and IRIS pressurizers. (author)

  4. The coefficient of restitution of pressurized balls: a mechanistic model

    Science.gov (United States)

    Georgallas, Alex; Landry, Gaëtan

    2016-01-01

    Pressurized, inflated balls used in professional sports are regulated so that their behaviour upon impact can be anticipated and allow the game to have its distinctive character. However, the dynamics governing the impacts of such balls, even on stationary hard surfaces, can be extremely complex. The energy transformations, which arise from the compression of the gas within the ball and from the shear forces associated with the deformation of the wall, are examined in this paper. We develop a simple mechanistic model of the dependence of the coefficient of restitution, e, upon both the gauge pressure, P_G, of the gas and the shear modulus, G, of the wall. The model is validated using the results from a simple series of experiments using three different sports balls. The fits to the data are extremely good for P_G > 25 kPa and consistent values are obtained for the value of G for the wall material. As far as the authors can tell, this simple, mechanistic model of the pressure dependence of the coefficient of restitution is the first in the literature. *%K Coefficient of Restitution, Dynamics, Inflated Balls, Pressure, Impact Model

  5. Pressure coefficient evolutions on the blades of a Savonius rotor

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, A.; Guignard, S. [UMRR 7343, Marseilles (France). Lab. IUSTI; Kamoun, B. [Faculte des Sciences de Sfax (Tunisia). Lab. de Physique

    2012-07-01

    Measurements of the pressure field distribution on the blades of a vertical axis Savonius wind machine are presented. The rotor used in the wind tunnel is a two blades cylindrical shape with a central gap. Pressure gauges are placed on each side of a blade, so the pressure jumps between intrados and extrados of a blade during a whole rotation are drawn. In the static configuration, the machine is disposed at various incidences. The determination of pressure jumps allows to calculate the static torque of the machine versus the incidence angle. In the dynamic situation the machine is rotating at various frequencies and gauges signals are varying dynamically of course with the incidence. The dynamic torque coefficient is calculated. Evolutions of the starting torque and starting conditions are then described and dynamic effects on torque evolution are presented. (orig.)

  6. Prediction of local loss coefficient for turbulent flow in axisymmetric sudden expansions with a chamfer: Effect of Reynolds number

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In

    2014-01-01

    Highlights: • Turbulent flow in axisymmetric sudden expansion with a chamfer is studied numerically. • Reynolds number dependency of the local loss coefficient is investigated. • Extended correlation is proposed for estimation of the local loss coefficient. - Abstract: This paper reports the pressure losses in turbulent flows through axisymmetric sudden expansions having a slight chamfer on the edge. A parametric study is performed for dimensionless chamfer lengths of 0–0.5, expansion ratios of 2–6, and chamfer angles of 0–45° in a Reynolds number range of 1 × 10 5 –8 × 10 5 . The chamfer effect on the expansion losses and its dependence on the Reynolds number are analyzed in detail along with a discussion of the relevant flow features. On the basis of numerical results, an existing correlation of the local loss coefficient is also extended to take into account the effect of the Reynolds number additionally

  7. Automatic estimation of pressure-dependent rate coefficients.

    Science.gov (United States)

    Allen, Joshua W; Goldsmith, C Franklin; Green, William H

    2012-01-21

    A general framework is presented for accurately and efficiently estimating the phenomenological pressure-dependent rate coefficients for reaction networks of arbitrary size and complexity using only high-pressure-limit information. Two aspects of this framework are discussed in detail. First, two methods of estimating the density of states of the species in the network are presented, including a new method based on characteristic functional group frequencies. Second, three methods of simplifying the full master equation model of the network to a single set of phenomenological rates are discussed, including a new method based on the reservoir state and pseudo-steady state approximations. Both sets of methods are evaluated in the context of the chemically-activated reaction of acetyl with oxygen. All three simplifications of the master equation are usually accurate, but each fails in certain situations, which are discussed. The new methods usually provide good accuracy at a computational cost appropriate for automated reaction mechanism generation.

  8. Pressure loss characteristics of LSTF steam generator heat-transfer tubes. Pressure loss increase due to tube internal instruments

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro

    1994-11-01

    The steam generator of the Large-Scale Test Facility (LSTF) includes 141 heat-transfer U-tubes with different lengths. Six U-tubes among them are furnished with 15 or 17 probe-type instruments (conduction probe with a thermocouple; CPT) protuberant into the primary side of the U-tubes. Other 135 U-tubes are not instrumented. This results in different hydraulic conditions between the instrumented and non-instrumented U-tubes with the same length. A series of pressure loss characteristics tests was conducted at a test apparatus simulating both types of U-tube. The following pressure loss coefficient (K CPT ) was reduced as a function of Reynolds number (Re) from these tests under single-phase water flow conditions. K CPT =0.16 5600≤Re≤52820, K CPT =60.66xRe -0.688 2420≤Re≤5600, K CPT =2.664x10 6 Re -2.06 1371≤Re≤2420. The maximum uncertainty is 22%. By using these results, the total pressure loss coefficients of full length U-tubes were estimated. It is clarified that the total pressure loss of the shortest instrumented U-tube is equivalent to that of the middle-length non-instrumented U-tube and also that a middle-length instrumented U-tube is equivalent to the longest non-instrumented U-tube. Concludingly. it is important to take account of the CPT pressure loss mentioned above in estimation of fluid behavior at the non-instrumented U-tubes either by using the LSTF experiment data from the CPT-installed U-tubes or by using any analytical codes. (author)

  9. Study of pressure losses in the EL 4 cluster

    International Nuclear Information System (INIS)

    Berriaud, Ch.

    1964-01-01

    The evolution of research on the EL-4 cluster is examined here from the pressure losses point of view. These may be split up into separate pressure losses along the rode and in pressure losses corresponding to various particularities of the cluster. Tests have been carried out on series of three or four clusters placed in a channel. Water was first used, and then carbon dioxide at 60 bars. In all cases the following two parameters were varied: the Reynolds' number, and the rotation of a cluster around its axis with respect to the surrounding clusters. The influence of the gap between to successive clusters has also been studied. The first tests were carried out on clusters without jackets, the subsequent ones on clusters fitted with jackets. It was thus possible to study various types of element assemblies. The results are given in the form of curves representing: the evolution of the independent pressure loss coefficients as a function of the Reynolds number. (author) [fr

  10. Automatic estimation of pressure-dependent rate coefficients

    KAUST Repository

    Allen, Joshua W.; Goldsmith, C. Franklin; Green, William H.

    2012-01-01

    A general framework is presented for accurately and efficiently estimating the phenomenological pressure-dependent rate coefficients for reaction networks of arbitrary size and complexity using only high-pressure-limit information. Two aspects of this framework are discussed in detail. First, two methods of estimating the density of states of the species in the network are presented, including a new method based on characteristic functional group frequencies. Second, three methods of simplifying the full master equation model of the network to a single set of phenomenological rates are discussed, including a new method based on the reservoir state and pseudo-steady state approximations. Both sets of methods are evaluated in the context of the chemically-activated reaction of acetyl with oxygen. All three simplifications of the master equation are usually accurate, but each fails in certain situations, which are discussed. The new methods usually provide good accuracy at a computational cost appropriate for automated reaction mechanism generation. This journal is © the Owner Societies.

  11. Sound absorption coefficient in situ: an alternative for estimating soil loss factors.

    Science.gov (United States)

    Freire, Rosane; Meletti de Abreu, Marco Henrique; Okada, Rafael Yuri; Soares, Paulo Fernando; GranhenTavares, Célia Regina

    2015-01-01

    The relationship between the sound absorption coefficient and factors of the Universal Soil Loss Equation (USLE) was determined in a section of the Maringá Stream basin, Paraná State, by using erosion plots. In the field, four erosion plots were built on a reduced scale, with dimensions of 2.0×12.5m. With respect to plot coverage, one was kept with bare soil and the others contained forage grass (Brachiaria), corn and wheat crops, respectively. Planting was performed without any type of conservation practice in an area with a 9% slope. A sedimentation tank was placed at the end of each plot to collect the material transported. For the acoustic system, pink noise was used in the measurement of the proposed monitoring, for collecting information on incident and reflected sound pressure levels. In general, obtained values of soil loss confirmed that 94.3% of material exported to the basin water came from the bare soil plot, 2.8% from the corn plot, 1.8% from the wheat plot, and 1.1% from the forage grass plot. With respect to the acoustic monitoring, results indicated that at 16kHz erosion plot coverage type had a significant influence on the sound absorption coefficient. High correlation coefficients were found in estimations of the A and C factors of the USLE, confirming that the acoustic technique is feasible for the determination of soil loss directly in the field. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Pressure loss tests for DR-BEP of fullsize 17 x 17 PWR fuel assembly

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Chun, Se Young; Chang, Seok Kyu; Won, Soon Youn; Cho, Young Rho; Kim, Bok Deuk; Min, Kyoung Ho

    1993-01-01

    This report describes the conditions, procedure and results in the pressure loss tests carried out for a double grid type debris resistance bottom end piece (DR-BEP) designed by KAERI. In this test, the pressure loss coefficients of the full size 17 x 17 PWR simulated fuel assembly with DR-BET and with standard-BEP were measured respectively, and the pressure loss coefficients of DR-BEP were compared with the coefficients of STD-BET. The test conditions fall within the ranges of loop pressure from 5.2 to 45 bar, loop temperature from 27 to 221 deg C and Reynolds number in fuel bundle from 2.17 x 10 4 to 3.85 x 10 5 . (Author) 5 refs., 18 figs., 5 tabs

  13. Static pressure and temperature coefficients of working standard microphones

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Cutanda Henriquez, Vicente; Torras Rosell, Antoni

    2016-01-01

    be a significant contribution to the uncertainty of the measurement. Determining the environmental coefficients of individual specimens of measurement microphones can be a straightforward though time-consuming procedure provided the appropriate facilities are available. An alternative is to determine them using...... coefficients. For this purpose, the environmental coefficients of some commercially available microphones have been determined experimentally, and whenever possible, compared with the coefficients determined numerically using the Boundary Element Method....... for these coefficients which are used for calibration purposes. Working standard microphones are not exempt of these influences. However, manufacturers usually provide a low frequency value of the environmental coefficient. While in some applications the influence of this coefficient may be negligible, in others it may...

  14. An experimental study of rotational pressure loss in rotor-stator gap

    Directory of Open Access Journals (Sweden)

    Yew Chuan Chong

    2017-06-01

    Full Text Available The annular gap between rotor and stator is an inevitable flow path of a throughflow ventilated electrical machine, but the flow entering the rotor-stator gap is subjected to the effects of rotation. The pressure loss and volumetric flow rate across the rotor-stator gap were measured and compared between rotating and stationary conditions. The experimental measurements found that the flow entering the rotor-stator gap is affected by an additional pressure loss. In the present study, the rotational pressure loss at the entrance of rotor-stator gap is characterised. Based upon dimensional analysis, the coefficient of entrance loss can be correlated with a dimensionless parameter, i.e. rotation ratio. The investigation leads to an original correlation for the entrance loss coefficient of rotor-stator gap arisen from the Coriolis and centrifugal effects in rotating reference frame.

  15. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  16. The static pressure and temperature coefficients of laboratory standard microphones

    DEFF Research Database (Denmark)

    Rasmussen, Knud

    1999-01-01

    , for a given type of microphone, can be described by a single function when the coefficients are normalized by their low-frequency value and the frequency is normalized with respect to the individual resonance frequency of the microphone. The theoretical results are supported by experimentally determined...... on an extended lumped parameter representation of the mechanical and acoustic elements of the microphone. The extension involves the frequency dependency of the dynamic diaphragm mass and stiffness as well as a first-order approximation of resonances in the back cavity. It was found that each coefficient...... coefficients for about twenty samples of microphone types B&K 4160 and B&K 4180....

  17. The effect of hydrostatic pressure on the anomalous sign reversal of the Hall coefficient in tellurium

    International Nuclear Information System (INIS)

    Balynas, V.; Dobrovolskis, Z.; Krotkus, A.; Hoerstel, W.

    1981-01-01

    In order to obtain information about the pressure behaviour of the higher lying second conduction band the dependences of the Hall coefficient of single crystalline tellurium on temperature (300 to 500 K) have been measured at atmospheric pressure and hydrostatic pressures of 500 and 800 MPa. The separation between the two conduction bands in Te decreases with increasing pressure. The anomalous sign reversal of the Hall coefficient can be well explained by a double-conduction band model

  18. Measurement of subcooled boiling pressure drop and local heat transfer coefficient in horizontal tube under LPLF conditions

    International Nuclear Information System (INIS)

    Baburajan, P.K.; Bisht, G.S.; Gupta, S.K.; Prabhu, S.V.

    2013-01-01

    Highlights: ► Measured subcooled boiling pressure drop and local heat transfer coefficient in horizontal tubes. ► Infra-red thermal imaging is used for wall temperature measurement. ► Developed correlations for pressure drop and local heat transfer coefficient. -- Abstract: Horizontal flow is commonly encountered in boiler tubes, refrigerating equipments and nuclear reactor fuel channels of pressurized heavy water reactors (PHWR). Study of horizontal flow under low pressure and low flow (LPLF) conditions is important in understanding the nuclear core behavior during situations like LOCA (loss of coolant accidents). In the present work, local heat transfer coefficient and pressure drop are measured in a horizontal tube under LPLF conditions of subcooled boiling. Geometrical parameters covered in this study are diameter (5.5 mm, 7.5 mm and 9.5 mm) and length (550 mm, 750 mm and 1000 mm). The operating parameters varied are mass flux (450–935 kg/m 2 s) and inlet subcooling (29 °C, 50 °C and 70 °C). Infra-red thermography is used for the measurement of local wall temperature to estimate the heat transfer coefficient in single phase and two phase flows with water as the working medium at atmospheric pressure. Correlation for single phase diabatic pressure drop ratio (diabatic to adiabatic) as a function of viscosity ratio (wall temperature to fluid temperature) is presented. Correlation for pressure drop under subcooled boiling conditions as a function of Boiling number (Bo) and Jakob number (Ja) is obtained. Correlation for single phase heat transfer coefficient in the thermal developing region is presented as a function of Reynolds number (Re), Prandtl number (Pr) and z/d (ratio of axial length of the test section to diameter). Correlation for two phase heat transfer coefficient under subcooled boiling condition is developed as a function of boiling number (Bo), Jakob number (Ja) and Prandtl number (Pr)

  19. Application of noise analysis technique for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors

    International Nuclear Information System (INIS)

    Shieh, D.J.; Upadhyaya, B.R.; Sweeney, F.J.

    1987-01-01

    A new technique, based on the noise analysis of neutron detector and core-exit coolant temperature signals, is developed for monitoring the moderator temperature coefficient of reactivity in pressurized water reactors (PWRs). A detailed multinodal model is developed and evaluated for the reactor core subsystem of the loss-of-fluid test (LOFT) reactor. This model is used to study the effect of changing the sign of the moderator temperature coefficient of reactivity on the low-frequency phase angle relationship between the neutron detector and the core-exit temperature noise signals. Results show that the phase angle near zero frequency approaches - 180 deg for negative coefficients and 0 deg for positive coefficients when the perturbation source for the noise signals is core coolant flow, inlet coolant temperature, or random heat transfer

  20. Assessment of the crossflow loss coefficient in Very High Temperature Reactor core - 15338

    International Nuclear Information System (INIS)

    Lee, S.N.; Tak, N.I.; Kim, M.H.; Noh, J.M.

    2015-01-01

    The Very High Temperature Reactor (VHTR) is a helium gas cooled and graphite moderated reactor. It was chosen as one of the Gen-4 reactors owing to its inherent safety. Various researches for prismatic gas-cooled reactors have been conducted for efficient and safe use. The prismatic VHTR consists of vertically stacked fuel blocks. Between the vertical fuel blocks, there is cross gap because of manufacturing tolerance or graphite change during the operation. This cross gap changes the coolant flow path, called a crossflow, which may affect the fuel temperature. Various tests and numerical studies have been conducted to predict the crossflow and loss coefficient. In the present study, the CFD calculation is conducted to draw the loss coefficient, and compared with Groehn, Kaburaki and General Atomics (GA) correlations. The results of the Groehn and Kaburaki correlations tend to decrease as the gap size increases, whereas the data of GA show the opposite. The loss coefficient given by the CFD calculation tends to maintain the regular value without regard to the gap size for the standard fuel block, like the Groehn correlation. However, the loss coefficient of the control fuel block increases as the gap size widens, like the GA results

  1. Intrathoracic Pressure Regulator for Blood Loss

    Science.gov (United States)

    2016-05-24

    hepatitis A antibody, and human immunodeficiency virus antibody), urine tests (drug screen I-abuse, marijuana, and a pregnancy test), and a 12-lead... sodium chloride; 250 mL over 2.5 minutes) were administered if systolic BP < 85 mmHg. Blood pressure, other hemodynamics, UO, and total amount of

  2. Anomalous composition dependence of the band gap pressure coefficients in In-containing nitride semiconductors

    DEFF Research Database (Denmark)

    Gorczyca, I.; Kamińska, A.; Staszczak, G.

    2010-01-01

    The pressure-induced changes in the electronic band structures of In-containing nitride alloys, InxGa1-xN and InxAl1-xN are examined experimentally as well as by ab initio calculations. It is found that the band gap pressure coefficients, dEg/dp, exhibit very large bowing with x, and calculations...

  3. Fuel assembly for pressure loss variable PWR type reactor

    International Nuclear Information System (INIS)

    Yoshikuni, Masaaki.

    1993-01-01

    In a PWR type reactor, a pressure loss control plate is attached detachably to a securing screw holes on the lower surface of a lower nozzle to reduce a water channel cross section and increase a pressure loss. If a fuel assembly attached with the pressure loss control plate is disposed at a periphery of the reactor core where the power is low and heat removal causes no significant problem, a flowrate at the periphery of the reactor core is reduced. Since this flowrate is utilized for removal of heat from fuel assemblies of high powder at the center of the reactor core where a pressure loss control plate is not attached, a thermal limit margin of the whole reactor core is increased. Thus, a limit of power peaking can be moderated, to obtain a fuel loading pattern improved with neutron economy. (N.H.)

  4. Numerical Investigation of Pressure Losses in Axisymmetric Sudden Expansion with a Chamfer

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Youngmin; Kim, Youngin; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, the pressure losses through axisymmetric sudden expansions with a chamfer are analyzed by means of numerical simulation, with an emphasis on the effect of the Reynolds number. In this study, we investigate numerically the turbulent flow in axisymmetric sudden expansions having a slight chamfer on the edge. With the aim of investigating the impact of Reynolds number on the expansion losses in a time-averaged sense, an extensive set of simulations is carried out. On the basis of numerical results, we also propose a general correlation to estimate the local loss coefficient in sudden expansions with a chamfer.

  5. Numerical Investigation of Pressure Losses in Axisymmetric Sudden Expansion with a Chamfer

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Youngin; Kim, Keung Koo

    2014-01-01

    In this paper, the pressure losses through axisymmetric sudden expansions with a chamfer are analyzed by means of numerical simulation, with an emphasis on the effect of the Reynolds number. In this study, we investigate numerically the turbulent flow in axisymmetric sudden expansions having a slight chamfer on the edge. With the aim of investigating the impact of Reynolds number on the expansion losses in a time-averaged sense, an extensive set of simulations is carried out. On the basis of numerical results, we also propose a general correlation to estimate the local loss coefficient in sudden expansions with a chamfer

  6. Modified pressure loss model for T-junctions of engine exhaust manifold

    Science.gov (United States)

    Wang, Wenhui; Lu, Xiaolu; Cui, Yi; Deng, Kangyao

    2014-11-01

    The T-junction model of engine exhaust manifolds significantly influences the simulation precision of the pressure wave and mass flow rate in the intake and exhaust manifolds of diesel engines. Current studies have focused on constant pressure models, constant static pressure models and pressure loss models. However, low model precision is a common disadvantage when simulating engine exhaust manifolds, particularly for turbocharged systems. To study the performance of junction flow, a cold wind tunnel experiment with high velocities at the junction of a diesel exhaust manifold is performed, and the variation in the pressure loss in the T-junction under different flow conditions is obtained. Despite the trend of the calculated total pressure loss coefficient, which is obtained by using the original pressure loss model and is the same as that obtained from the experimental results, large differences exist between the calculated and experimental values. Furthermore, the deviation becomes larger as the flow velocity increases. By improving the Vazsonyi formula considering the flow velocity and introducing the distribution function, a modified pressure loss model is established, which is suitable for a higher velocity range. Then, the new model is adopted to solve one-dimensional, unsteady flow in a D6114 turbocharged diesel engine. The calculated values are compared with the measured data, and the result shows that the simulation accuracy of the pressure wave before the turbine is improved by 4.3% with the modified pressure loss model because gas compressibility is considered when the flow velocities are high. The research results provide valuable information for further junction flow research, particularly the correction of the boundary condition in one-dimensional simulation models.

  7. Experimental study on the minimum drag coefficient of supercritical pressure water in horizontal tubes

    International Nuclear Information System (INIS)

    Lei, Xianliang; Li, Huixiong; Guo, YuMeng; Zhang, Qing; Zhang, Weiqiang; Zhang, Qian

    2016-01-01

    Highlights: • The minimum drag coefficient phenomenon (MDC) has been observed and further investigated. • Effects of heat flux, mass flux and pressure to MDC have been discussed. • A series of comparisons between existing correlations and data have been conducted. • Two correlations of drag coefficient are proposed for isothermal and nonisothermal flow. - Abstract: Hydraulic resistance and its components are of great importance for understanding the turbulence nature of supercritical fluid and establishing prediction methods. Under supercritical pressures, the hydraulic resistance of the fluid exhibits a “pit” in the regions near its pseudo-critical point, which is hereafter called the minimum drag coefficient phenomenon. However, this special phenomenon was paid a little attention before. Hence systematical experiments have been carried out to investigate the hydraulic resistance of supercritical pressure water in both adiabatic and heated horizontal tubes. Parametric effects of heat flux, pressure and mass fluxes to drag coefficient are further compared. It is found that almost all of the existing correlations don’t agree well with the experimental data due to the insufficient consideration of thermal-properties near the pseudocritical point. Two correlations of the drag coefficients are finally proposed by introducing the new variable of the derivative of density with respect to temperature or Prandtl number, which can better predict the drag coefficient of isothermal and nonisothermal flow respectively.

  8. Effect of interfacial turbulence and accommodation coefficient on CFD predictions of pressurization and pressure control in cryogenic storage tank

    Science.gov (United States)

    Kassemi, Mohammad; Kartuzova, Olga

    2016-03-01

    Pressurization and pressure control in cryogenic storage tanks are to a large extent affected by heat and mass transport across the liquid-vapor interface. These mechanisms are, in turn, controlled by the kinetics of the phase change process and the dynamics of the turbulent recirculating flows in the liquid and vapor phases. In this paper, the effects of accommodation coefficient and interfacial turbulence on tank pressurization and pressure control simulations are examined. Comparison between numerical predictions and ground-based measurements in two large liquid hydrogen tank experiments, performed in the K-site facility at NASA Glenn Research Center (GRC) and the Multi-purpose Hydrogen Test Bed (MHTB) facility at NASA Marshall Space Flight Center (MSFC), are used to show the impact of accommodation coefficient and interfacial and vapor phase turbulence on evolution of pressure and temperatures in the cryogenic storage tanks. In particular, the self-pressurization comparisons indicate that: (1) numerical predictions are essentially independent of the magnitude of the accommodation coefficient; and (2) surprisingly, laminar models sometimes provide results that are in better agreement with experimental self-pressurization rates, even in parametric ranges where the bulk flow is deemed fully turbulent. In this light, shortcomings of the present CFD models, especially, numerical treatments of interfacial mass transfer and turbulence, as coupled to the Volume-of-Fluid (VOF) interface capturing scheme, are underscored and discussed.

  9. Effective stresses and shear failure pressure from in situ Biot's coefficient, Hejre Field, North Sea

    DEFF Research Database (Denmark)

    Regel, Jeppe Bendix; Orozova-Bekkevold, Ivanka; Andreassen, Katrine Alling

    2017-01-01

    , is significantly different from 1. The log-derived Biot's coefficient is above 0.8 in the Shetland Chalk Group and in the Tyne Group, and 0.6-0.8 in the Heno Sandstone Formation. We show that the effective vertical and horizontal stresses obtained using the log-derived Biot's coefficient result in a drilling......We propose a combination of Biot's equations for effective stress and the expression for shear failure in a rock to obtain an expression for minimum pore pressure in a stable vertical well bore. We show that a Biot's coefficient calculated from logging data in the Hejre Field, North Sea...

  10. Measurement procedure for the determination of thermal exchange coefficient for subsea pipelines at elevated pressure levels

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Luis Fernando A.; Farias, Paula S.C.; Martins, Fabio J.W.A.; Rabello, Pedro C.; Barros Junior, Julio M. [Pontificia Universidade Catolica (PUC-Rio), RJ (Brazil). Dept. de Engenharia Mecanica; Lopes Junior, Fernando M.; Silva Junior, Jose Fernando; Castro, Adriana M.; Santos, Augusto A.; Pessanha, Maikon C.R. [Technip, Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The present paper describes a methodology successfully employed to determine the Thermal Exchange Coefficient - TEC - for insulated sub sea flexible lines up to a pressure level of 200 bar. In this methodology, controlled internal electrical heating was employed, together with temperature sensors installed at the inner and outer surfaces of the line. The instrumented line sample was placed in a hyperbaric chamber filled with water. Two methods were employed in parallel to determine the line TEC value. In the first method, the TEC value was determined by direct measurement of the radial heat flux by the use of heat flux sensors. The readings of these sensors, together with the inner-to-outer surface temperature difference and geometric parameters, yielded the desired TEC value. In the second method, the radial heat flux was obtained as the difference between the total energy generated by the electrical heater installed in the interior of the sample and the heat losses through the end connectors, evaluated by the readings of temperature sensors installed in covers that surrounded the end connectors. The knowledge of the cover geometry, thermal properties and the temperature readings allowed for an accurate estimate of the heat lost through the covers. Both measuring methods were backed by a detailed uncertainty analysis. A calibration procedure of the second method was performed from zero to 100 bar, the pressure range where the calibration of the heat flux sensor is valid. Beyond 100 bar and up to 200 bar, the TEC values were obtained by the second method, corrected by the calibration procedure extrapolated from the 0-100 bar range. The TEC values obtained were valid under an uncertainty level of {+-} 5%. (author)

  11. Analytical Modeling Of The Steinmetz Coefficient For Single-Phase Transformer Eddy Current Loss Prediction

    Directory of Open Access Journals (Sweden)

    T. Aly Saandy

    2015-08-01

    Full Text Available Abstract This article presents to an analytical calculation methodology of the Steinmetz coefficient applied to the prediction of Eddy current loss in a single-phase transformer. Based on the electrical circuit theory the active power consumed by the core is expressed analytically in function of the electrical parameters as resistivity and the geometrical dimensions of the core. The proposed modeling approach is established with the duality parallel series. The required coefficient is identified from the empirical Steinmetz data based on the experimented active power expression. To verify the relevance of the model validations both by simulations with two in two different frequencies and measurements were carried out. The obtained results are in good agreement with the theoretical approach and the practical results.

  12. Noise analysis method for monitoring the moderator temperature coefficient of pressurized water reactors: Neural network calibration

    International Nuclear Information System (INIS)

    Thomas, J.R. Jr.; Adams, J.T.

    1994-01-01

    A neural network was trained with data for the frequency response function between in-core neutron noise and core-exit thermocouple noise in a pressurized water reactor, with the moderator temperature coefficient (MTC) as target. The trained network was subsequently used to predict the MTC at other points in the same fuel cycle. Results support use of the method for operating pressurized water reactors provided noise data can be accumulated for several fuel cycles to provide a training base

  13. The determination of the pressure-viscosity coefficient of two traction oils using film thickness measurements

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2010-01-01

    The pressure-viscosity coefficients of two commercial traction fluids are determined by fitting calculation results on accurate film thickness measurements, obtained at a wide range of speeds, and different temperatures. Film thickness values are calculated using a numerical method and approximation

  14. A Simple Student Laboratory on Osmotic Flow, Osmotic Pressure, and the Reflection Coefficient.

    Science.gov (United States)

    Feher, Joseph J.; Ford, George D.

    1995-01-01

    Describes a laboratory exercise containing a practical series of experiments that novice students can perform within two hours. The exercise provides a confirmation of van't Hoff's law while placing more emphasis on osmotic flow than pressure. Students can determine parameters such as the reflection coefficient which stress the interaction of both…

  15. Evaluation of heat transfer coefficient of tungsten filaments at low pressures and high temperatures

    International Nuclear Information System (INIS)

    Chondrakis, N.G.; Topalis, F.V.

    2011-01-01

    The paper presents an experimental method for the evaluation of the heat transfer coefficient of tungsten filaments at low pressures and high temperatures. For this purpose an electrode of a T5 fluorescent lamp was tested under low pressures with simultaneous heating in order to simulate the starting conditions in the lamp. It was placed in a sealed vessel in which the pressure was varied from 1 kM (kilo micron) to 760 kM. The voltage applied to the electrode was in the order of the filament's voltage of the lamp at the normal operation with the ballast during the preheating process. The operating frequency ranged from DC to 50 kHz. The experiment targeted on estimating the temperature of the electrode at the end of the first and the ninth second after initiating the heating process. Next, the heat transfer coefficient was calculated at the specific experimental conditions. A mathematical model based on the results was developed that estimates the heat transfer coefficient. The experiments under different pressures confirm that the filament's temperature strongly depends on the pressure.

  16. The impact of fuel temperature reactivity coefficient on loss of reactivity control accident

    International Nuclear Information System (INIS)

    Park, J. H.; Ryu, E. H.; Song, Y. M.; Jung, J. Y.

    2012-01-01

    Nuclear reactors experience small power fluctuations or anticipated operational transients during even normal power operation. During normal operation, the reactivity is mainly controlled by liquid zone controllers, adjuster rods, mechanical control absorbers, and moderator poison. Even when the reactor power is increased abruptly and largely from an accident and when reactor control systems cannot be actuated quickly due to a fast transient, the reactor should be controlled and stabilized by its inherent safety parameter, such as a negative PCR (Power Coefficient of Reactivity) feedback. A PWR (Pressurized Water Reactor), it is well designed for the reactor to have a negative PCR so that the reactor can be safely shut down or stabilized whenever an abrupt reactivity insertion into the reactor core occurs or the reactor power is abruptly increased. However, it is known that a CANDU reactor has a small amount of PCR, as either negative or positive, because of the different design basis and safety concepts from a PWR. CNSC's regulatory and safety regime has stated that; The PCR of CANDU reactors does not pose a significant risk. Consistent with Canadian nuclear safety requirements, nuclear power plants must have an appropriate combination of inherent and engineered safety features incorporated into the design of the reactor safety and control systems. A reactor design that has a PCR is quite acceptable provided that the reactor is stable against power fluctuations, and that the probability and consequences of any potential accidents that would be aggravated by a positive reactivity feedback are maintained within CNSCprescribed limits. Recently, it was issued licensing the refurbished Wolsong unit 1 in Korea to be operated continuously after its design lifetime in which the calculated PCR was shown to have a small positive value by applying the recent physics code systems, which are composed of WIMS IST, DRAGON IST, and RFSP IST. These code systems were transferred

  17. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Science.gov (United States)

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  18. Vapour pressures and osmotic coefficients of binary mixtures containing alcohol and pyrrolidinium-based ionic liquids

    International Nuclear Information System (INIS)

    Calvar, N.; Domínguez, Á.; Macedo, E.A.

    2013-01-01

    Highlights: • Osmotic coefficients of alcohols with pyrrolidinium ILs are determined. • Experimental data were correlated with extended Pitzer model of Archer and MNRTL. • Mean molal activity coefficients and excess Gibbs free energies were calculated. • The results have been interpreted in terms of interactions. -- Abstract: The osmotic and activity coefficients and vapour pressures of mixtures containing primary (1-propanol, 1-butanol and 1-pentanol) and secondary (2-propanol and 2-butanol) alcohols with pyrrolidinium-based ionic liquids (1-butyl-1-methyl pyrrolidinium bis(trifluoromethylsulfonyl)imide, C 4 MpyrNTf 2 , and 1-butyl-1-methyl pyrrolidinium trifluoromethanesulfonate, C 4 MpyrTFO) have been experimentally determined at T = 323.15 K. For the experimental measurements, the vapour pressure osmometry technique has been used. The results on the influence of the structure of the alcohol and of the anion of the ionic liquid on the determined properties have been discussed and compared with literature data. For the correlation of the osmotic coefficients obtained, the Extended Pitzer model of Archer and the Modified Non-Random Two Liquids model were applied. The mean molal activity coefficients and the excess Gibbs energy for the studied mixtures were calculated from the parameters obtained in the correlation

  19. Development of the loss coefficient correlation for cross flow between graphite fuel blocks in the core of prismatic very high temperature reactor-PMR200

    International Nuclear Information System (INIS)

    Lee, Jeong-Hun; Cho, Hyoung-Kyu; Park, Goon-Cherl

    2016-01-01

    Highlights: • Cross flow experimental data are produced with wedge-shaped and parallel gaps. • The results of a CFD analysis and experimental data are in good agreement. • Pressure loss coefficient for the cross gap between fuel blocks in PMR200 is found. • A new correlation of the cross flow loss coefficient for PMR200 is proposed. - Abstract: The core of the very high temperature reactor (VHTR) PMR200 (a prismatic modular reactor rated at 200 MW of thermal power) consists of hexagonal prismatic fuel blocks and reflector blocks made of graphite. If the core bypass flow ratio increases, the coolant channel flow is decreased and can then lower the heat removal efficiency, resulting in a locally increased fuel block temperature. The coolant channels in the fuel blocks are connected to bypass gaps by the cross gap, complicating flow distribution in the VHTR core. Therefore, reliable estimation of the bypass flow is highly important for the design and safety analysis of the VHTR core. Because of the complexity of the core geometry and gap configuration, it is challenging to predict the flow distribution in the VHTR core. To analyze this flow distribution accurately, it is necessary to determine the cross flow phenomena, and the loss coefficient across the cross gap has to be evaluated to determine the flow distribution in the VHTR core when a lumped parameter code or a flow network analysis code that uses the correlation of the loss coefficient is employed. The purpose of this paper is to develop a loss coefficient correlation applicable to the cross gap in the PMR200 core. The cross flow was evaluated experimentally using the difference between the measured inlet and outlet mass flow rates. Next, the applicability of a commercial computational fluid dynamics (CFD) code, CFX 15, was confirmed by comparing the experimental data and CFD analysis results. To understand the cross flow phenomena, the loss coefficient was evaluated; in the high Reynolds number region

  20. Development of the loss coefficient correlation for cross flow between graphite fuel blocks in the core of prismatic very high temperature reactor-PMR200

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong-Hun, E-mail: huny12@snu.ac.kr; Cho, Hyoung-Kyu, E-mail: chohk@snu.ac.kr; Park, Goon-Cherl, E-mail: parkgc@snu.ac.kr

    2016-10-15

    Highlights: • Cross flow experimental data are produced with wedge-shaped and parallel gaps. • The results of a CFD analysis and experimental data are in good agreement. • Pressure loss coefficient for the cross gap between fuel blocks in PMR200 is found. • A new correlation of the cross flow loss coefficient for PMR200 is proposed. - Abstract: The core of the very high temperature reactor (VHTR) PMR200 (a prismatic modular reactor rated at 200 MW of thermal power) consists of hexagonal prismatic fuel blocks and reflector blocks made of graphite. If the core bypass flow ratio increases, the coolant channel flow is decreased and can then lower the heat removal efficiency, resulting in a locally increased fuel block temperature. The coolant channels in the fuel blocks are connected to bypass gaps by the cross gap, complicating flow distribution in the VHTR core. Therefore, reliable estimation of the bypass flow is highly important for the design and safety analysis of the VHTR core. Because of the complexity of the core geometry and gap configuration, it is challenging to predict the flow distribution in the VHTR core. To analyze this flow distribution accurately, it is necessary to determine the cross flow phenomena, and the loss coefficient across the cross gap has to be evaluated to determine the flow distribution in the VHTR core when a lumped parameter code or a flow network analysis code that uses the correlation of the loss coefficient is employed. The purpose of this paper is to develop a loss coefficient correlation applicable to the cross gap in the PMR200 core. The cross flow was evaluated experimentally using the difference between the measured inlet and outlet mass flow rates. Next, the applicability of a commercial computational fluid dynamics (CFD) code, CFX 15, was confirmed by comparing the experimental data and CFD analysis results. To understand the cross flow phenomena, the loss coefficient was evaluated; in the high Reynolds number region

  1. Experimental and numerical characterization of wind-induced pressure coefficients on nuclear buildings and chimney exhausts

    Energy Technology Data Exchange (ETDEWEB)

    Ricciardi, Laurent, E-mail: laurent.ricciardi@irsn.fr; Gélain, Thomas; Soares, Sandrine

    2015-10-15

    Highlights: • Experiments on scale models of nuclear buildings and chimney exhausts were performed. • Pressure coefficient fields on buildings are shown for various wind directions. • Evolution of pressure coefficient vs U/W ratio is given for various chimney exhausts. • RANS simulations using SST k–ω turbulence model were performed on most studied cases. • A good agreement is overall observed, with Root Mean Square Deviation lower than 0.15. - Abstract: Wind creates pressure effects on different surfaces of buildings according to their exposure to the wind, in particular at external communications. In nuclear facilities, these effects can change contamination transfers inside the building and can even lead to contamination release into the environment, especially in damaged (ventilation stopped) or accidental situations. The diversity of geometries of facilities requires the use of a validated code for predicting pressure coefficients, which characterize the wind effect on the building walls and the interaction between the wind and chimney exhaust. The first aim of a research program launched by the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), was therefore to acquire experimental data of the mean pressure coefficients for different geometries of buildings and chimneys through wind tunnel tests and then to validate a CFD code (ANSYS CFX) from these experimental results. The simulations were performed using a steady RANS approach and a two-equation SST k–ω turbulence model. After a mesh sensitivity study for one configuration of building and chimney, a comparison was carried out between the numerical and experimental values for other studied configurations. This comparison was generally satisfactory, averaged over all measurement points, with values of Root Mean Square Deviations lower than 0.15 for most cases.

  2. Numerical determination of lateral loss coefficients for subchannel analysis in nuclear fuel bundles

    Energy Technology Data Exchange (ETDEWEB)

    Sin Kim; Goon-Cherl Park [Seoul National Univ., Seoul (Korea, Republic of)

    1995-09-01

    An accurate prediction of cross-flow based on detailed knowledge of the velocity field in subchannels of a nuclear fuel assembly is of importance in nuclear fuel performance analysis. In this study, the low-Reynolds number {kappa}-{epsilon} turbulence model has been adopted in two adjacent subchannels with cross-flow. The secondary flow is estimated accurately by the anisotropic algebraic Reynolds stress model. This model was numerically calculated by the finite element method and has been verified successfully through comparison with existing experimental data. Finally, with the numerical analysis of the velocity field in such subchannel domain, an analytical correlation of the lateral loss coefficient is obtained to predict the cross-flow rate in subchannel analysis codes. The correlation is expressed as a function of the ratio of the lateral flow velocity to the donor subchannel axial velocity, recipient channel Reynolds number and pitch-to-diameter.

  3. Determination of air and hydrofoil pressure coefficient by laser doppler anemometry

    Directory of Open Access Journals (Sweden)

    Ristić Slavica S.

    2010-01-01

    Full Text Available Some results of experiments performed in water cavitation tunnel are presented. Pressure coefficient (Cp was experimentally determined by Laser Doppler Anemometry (LDA measurements. Two models were tested: model of airplane G4 (Super Galeb and hydrofoil of high speed axial pump. These models are not prepared for conventional pressure measurements, so that LDA is applied for Cp determination. Numerical results were obtained using a code for average Navier-Stokes equations solutions. Comparisons between computational and experimental results prove the effectiveness of the LDA. The advantages and disadvantages of LDA application are discussed. Flow visualization was made by air bubbles.

  4. Performance potential of mechanical ventilation systems with minimized pressure loss

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2013-01-01

    simulations that quantify fan power consumption, heating demand and indoor environmental conditions. The system was designed with minimal pressure loss in the duct system and heat exchanger. Also, it uses state-of-the-art components such as electrostatic precipitators, diffuse ceiling inlets and demand......In many locations mechanical ventilation has been the most widely used principle of ventilation over the last 50 years but the conventional system design must be revised to comply with future energy requirements. This paper examines the options and describes a concept for the design of mechanical...... ventilation systems with minimal pressure loss and minimal energy use. This can provide comfort ventilation and avoid overheating through increased ventilation and night cooling. Based on this concept, a test system was designed for a fictive office building and its performance was documented using building...

  5. Comparison of boiling heat transfer coefficient and pressure drop correlations for evaporators

    International Nuclear Information System (INIS)

    Eskin, N.; Arslan, G.

    2009-01-01

    Evaporator design is an important aspect for the HVAC industry. As the demand for more efficient and compact heat exchangers increase, researches on estimation of two-phase flow heat transfer and pressure drop gain importance. Due to complexity of the hydrodynamic and heat transfer of the two-phase flow, there are many experimental studies available for refrigerants int he literature. In this study, a model for boiling heat transfer in a horizontal tube has been developed and the simulation results are compared with experimental ones published in the literature. In these comparisons, heat transfer coefficient is calculated by using Kattan-Thome-Favrat (1998), Shah (1982), Kandilikar (1990), Chaddock and Brunemann (1967) correlations under different operational conditions such as saturation pressure, mass flux, the type of refrigerant and two phase flow pattern. Besides that flow pattern has also been considered in the simulation by using Thome and El Hajal (2002) model. For pressure drop Lockhart-Martinelli (1949), Mueller-Steinhagen-Hack (1986) and Groennerund (1979) correlations are used in simulations. Local vapor quality change at each experimental condition through the model is determined. Roughness is an important parameter for frictional pressure drop. Friction coefficient is determined by using Churchill (1977) model. (author)

  6. Giant Pressure-Induced Enhancement of Seebeck Coefficient and Thermoelectric Efficiency in SnTe

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Jason; Kumar, Ravhi; Park, Changyong; Kenney-Benson, Curtis; Cornelius, Andrew; Velisavljevic, Nenad (CIW); (LANL); (UNLV)

    2017-10-30

    The thermoelectric properties of polycrystalline SnTe have been measured up to 4.5 GPa at 330 K. SnTe shows an enormous enhancement in Seebeck coefficient, greater than 200 % after 3 GPa, which correlates to a known pressure-induced structural phase transition that is observed through simultaneous in situ X-ray diffraction measurement. Electrical resistance and relative changes to the thermal conductivity were also measured, enabling the determination of relative changes in the dimensionless figure of merit (ZT), which increases dramatically after 3 GPa, reaching 350 % of the lowest pressure ZT value. The results demonstrate a fundamental relationship between structure and thermoelectric behaviours and suggest that pressure is an effective tool to control them.

  7. Calculation of the net emission coefficient of an air thermal plasma at very high pressure

    International Nuclear Information System (INIS)

    Billoux, T; Cressault, Y; Teulet, Ph; Gleizes, A

    2012-01-01

    The aim of this paper is to present an accurate evaluation of the phenomena appearing for high pressure air plasmas supposed to be in local thermodynamic equilibrium (LTE). In the past, we already calculated the net emission coefficient for air mixtures at atmospheric pressure and for temperatures up to 30kK (molecular contribution being restricted to 10kK). Unfortunately, the existence of high pressures does not allow us to use this database due to the non-ideality of the plasma (Viriel and Debye corrections, energy cut-off ...), and due to the significant shifts of molecular reactions towards upper temperatures. Consequently, this paper proposes an improvement of our previous works with a consideration of high pressure corrections in the composition algorithm in order to take into account the pressure effects, and with a new calculation of all the contributions of the plasma radiation (atomic lines and continuum, molecular continuum, and molecular bands) using an updated database. A particular attention is paid to calculate the contribution of all the major molecular band systems to the radiation: O 2 (Schumann–Runge), N 2 (VUV, 1st and 2nd positive), NO (IR, β, γ, δ, element of ) and N 2 + (1st negative and Meinel). The discrete atomic lines and molecular bands radiation including the overlapping are calculated by a line-by-line method up to 30kK and 100 bar. This updated database is validated in the case of optically thin plasmas and pressure of 1bar by the comparison of our integrated emission strength with the published results. Finally, this work shows the necessity to extend the molecular radiation database up to 15kK at high pressure (bands and continuum) since their corresponding contributions could not be neglected at high temperature.

  8. Nonstationary pressure build up in full-pressure containments after a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Mansfeld, G.

    1977-01-01

    The time histories of pressure, temperature and pressure difference during the pressure build up phase of a loss-of-coolant accident (LOCA) in the primary system in full-pressure containments of water cooled nuclear power reactors are treated. These are important for the design of such containments. The experiments within the German research program RS 50 ''Druckverteilung im Containment'' offered, for the first time, the opportunity to observe experimentally fluid-dynamic processes in a multiple divided full-pressure containment, and to test at the same time, computer codes which serve to describe the physical processes during the LOCA. The comparison of the results calculated by the computer codes ZOCO VI and DDIFF with the experimental results showed apparent deviations by special arrangements of the compartments and the vent flow paths of a model containment for the calculation of time dependent pressure-, temperature- and pressure difference-histories. The deviations lead to the development of the analytical model and computer code COFLOW. This new model was primarily designed to deal with the fluid-dynamic processes in the beginning phase of the blowdown as maximal pressure differences appear. Furthermore, it can be used to determine the maximum containment pressure, as well as for long term calculations. The analytical model and computer code COFLOW shows a better correlation between theory and experiment than previous codes

  9. Pressure-induced positive electrical resistivity coefficient in Ni-Nb-Zr-H glassy alloy

    Science.gov (United States)

    Fukuhara, M.; Gangli, C.; Matsubayashi, K.; Uwatoko, Y.

    2012-06-01

    Measurements under hydrostatic pressure of the electrical resistivity of (Ni0.36Nb0.24Zr0.40)100-xHx (x = 9.8, 11.5, and 14) glassy alloys have been made in the range of 0-8 GPa and 0.5-300 K. The resistivity of the (Ni0.36Nb0.24Zr0.40)86H14 alloy changed its sign from negative to positive under application of 2-8 GPa in the temperature range of 300-22 K, coming from electron-phonon interaction in the cluster structure under pressure, accompanied by deformation of the clusters. In temperature region below 22 K, the resistivity showed negative thermal coefficient resistance by Debye-Waller factor contribution, and superconductivity was observed at 1.5 K.

  10. Effect of pressure on heat transfer coefficient at the metal/mold interface of A356 aluminum alloy

    DEFF Research Database (Denmark)

    Fardi Ilkhchy, A.; Jabbari, Masoud; Davami, P.

    2012-01-01

    The aim of this paper is to correlate interfacial heat transfer coefficient (IHTC) to applied external pressure, in which IHTC at the interface between A356 aluminum alloy and metallic mold during the solidification of casting under different pressures were obtained using the inverse heat...... conduction problem (IHCP) method. The method covers the expedient of comparing theoretical and experimental thermal histories. Temperature profiles obtained from thermocouples were used in a finite difference heat flow program to estimate the transient heat transfer coefficients. The new simple formula...... was presented for correlation between external pressure and heat transfer coefficient. Acceptable agreement with data in literature shows the accuracy of the proposed formula....

  11. Analysis of loss-of-coolant accidents in pressurized water reactors

    International Nuclear Information System (INIS)

    Moldaschl, H.

    1982-01-01

    Analysis of loss-of-coolant accidents in pressurized water reactors -Quantification of the influence of leak size, control assembly worth, boron concentration and initial power by a dynamic operations criterion. Neutronic and thermohydraulic behaviour of a pressurized water reactor during a loss-of-coolant accident (LOCA) is mainly influenced by -change of fuel temperature, -void in the primary coolant. They cause a local stabilization of power density, that means that also in the case of small leaks local void is the main stabilization effect. As a consequence the increase of fuel temperature remains very small even under extremely hypothetical assumptions: small leak, positive reactivity feedback (positive coolant temperature coefficient, negative density coefficient) at the beginning of the accident and all control assemblies getting stuck. Restrictions which have been valid up to now for permitted start-up conditions to fulfill inherent safety requirements can be lossened substantially by a dynamic operations criterion. Burnable poisons for compensation of reactivity theorefore can be omitted. (orig.)

  12. Rate Coefficient Determinations for H + NO2 → OH + NO from High Pressure Flow Reactor Measurements.

    Science.gov (United States)

    Haas, Francis M; Dryer, Frederick L

    2015-07-16

    Rate coefficients for the reaction H + NO2 → OH + NO (R1) have been determined over the nominal temperature and pressure ranges of 737-882 K and 10-20 atm, respectively, from measurements in two different flow reactor facilities: one laminar and one turbulent. Considering the existing database of experimental k1 measurements, the present conditions add measurements of k1 at previously unconsidered temperatures between ∼820-880 K, as well as at pressures that exceed existing measurements by over an order of magnitude. Experimental measurements of NOx-perturbed H2 oxidation have been interpreted by a quasi-steady state NOx plateau (QSSP) method. At the QSSP conditions considered here, overall reactivity is sensitive only to the rates of R1 and H + O2 + M → HO2 + M (R2.M). Consequently, the ratio of k1 to k2.M may be extracted as a simple algebraic function of measured NO2, O2, and total gas concentrations with only minimal complication (within measurement uncertainty) due to treatment of overall gas composition M that differs slightly from pure bath gas B. Absolute values of k1 have been determined with reference to the relatively well-known, pressure-dependent rate coefficients of R2.B for B = Ar and N2. Rate coefficients for the title reaction determined from present experimental interpretation of both laminar and turbulent flow reactor results appear to be in very good agreement around a representative value of 1.05 × 10(14) cm(3) mol(-1) s(-1) (1.74 × 10(-10) cm(3) molecule(-1) s(-1)). Further, the results of this study agree both with existing low pressure flash photolysis k1 determinations of Ko and Fontijn (J. Phys. Chem. 95 3984) near 760 K as well as a present fit to the theoretical expression of Su et al. (J. Phys. Chem. A 106 8261). These results indicate that, over the temperature range considered in this study and up to at least 20 atm, net chemistry due to stabilization of the H-NO2 reaction intermediate to form isomers of HNO2 may proceed at

  13. Influence of a variable Rayleigh scattering-loss coefficient on the light backscattering in multimode optical fibers.

    Science.gov (United States)

    Bisyarin, M A; Kotov, O I; Hartog, A H; Liokumovich, L B; Ushakov, N A

    2017-06-01

    The recently developed diffraction technique of analytical investigation of the Rayleigh backscattering produced by an incident fundamental mode in a multimode optical fiber with an arbitrary refractive index profile is supplemented by taking into account the Rayleigh scattering-loss coefficient, which could be variable within the fiber cross section. The relative changes in various radial and azimuthal modes' excitation levels, due to some typical radial dependences of this coefficient, are computed for the quadratic- and step-index fibers. It is stated that the excitation efficiency could either rise or decay for different modes. The effect of the variable Rayleigh scattering-loss coefficient is shown to be more noticeable in the fibers with a quadratic refractive index profile, whereas it is negligible in actual multimode step-index fibers.

  14. Thermodiffusion Coefficient Analysis of n-Dodecane /n-Hexane Mixture at Different Mass Fractions and Pressure Conditions

    Science.gov (United States)

    Lizarraga, Ion; Bou-Ali, M. Mounir; Santamaría, C.

    2018-03-01

    In this study, the thermodiffusion coefficient of n-dodecane/n-hexane binary mixture at 25 ∘C mean temperature was determined for several pressure conditions and mass fractions. The experimental technique used to determine the thermodiffusion coefficient was the thermograviational column of cylindrical configuration. In turn, thermophysical properties, such as density, thermal expansion, mass expansion and dynamic viscosity up to 10 MPa were also determined. The results obtained in this work showed a linear relation between the thermophysical properties and the pressure. Thermodiffusion coefficient values confirm a linear effect when the pressure increases. Additionally, a new correlation based on the thermodiffusion coefficient for n C12/n C6 binary mixture at 25 ∘C temperature for any mass fraction and pressures, which reproduces the data within the experimental error, was proposed.

  15. Blood flow vs. venous pressure effects on filtration coefficient in oleic acid-injured lung.

    Science.gov (United States)

    Anglade, D; Corboz, M; Menaouar, A; Parker, J C; Sanou, S; Bayat, S; Benchetrit, G; Grimbert, F A

    1998-03-01

    On the basis of changes in capillary filtration coefficient (Kfc) in 24 rabbit lungs, we determined whether elevations in pulmonary venous pressure (Ppv) or blood flow (BF) produced differences in filtration surface area in oleic acid-injured (OA) or control (Con) lungs. Lungs were cyclically ventilated and perfused under zone 3 conditions by using blood and 5% albumin with no pharmacological modulation of vascular tone. Pulmonary arterial, venous, and capillary pressures were measured by using arterial, venous, and double occlusion. Before and during each Kfc-measurement maneuver, microvascular/total vascular compliance was measured by using venous occlusion. Kfc was measured before and 30 min after injury, by using a Ppv elevation of 7 cmH2O or a BF elevation from 1 to 2 l . min-1 . 100 g-1 to obtain a similar double occlusion pressure. Pulmonary arterial pressure increased more with BF than with Ppv in both Con and OA lungs [29 +/- 2 vs. 19 +/- 0.7 (means +/- SE) cmH2O; P Kfc (200 +/- 40 vs. 83 +/- 14%, respectively; P < 0.01) and microvascular/total vascular compliance ratio (86 +/- 4 vs. 68 +/- 5%, respectively; P < 0.01) increased more with BF than with Ppv. In conclusion, for a given OA-induced increase in hydraulic conductivity, BF elevation increased filtration surface area more than did Ppv elevation. The steep pulmonary pressure profile induced by increased BF could result in the recruitment of injured capillaries and could also shift downstream the compression point of blind (zone 1) and open injured vessels (zone 2).

  16. Estimation on the Flow Phenomena and the Pressure Loss for the Inlet Part of a Research Reactor Vessel

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Oh, Jae Min; Seo, Jae Kwang; Yoon, Ju Hyeon; Lee, Doo Jeong

    2009-01-01

    For a research reactor, a conceptual primary cooling system (PCS) was designed for an adequate cooling to the reactor core. The developed primary cooling circuit consisted of decay tanks, pumps, heat exchangers, vacuum breakers, some isolation and check valves, connection piping, and instruments. The main function of the primary cooling pumps (PCPs) of the PCS was to circulate the reactor coolant through the fuel core and the heat exchangers during a normal operation. The head according to the design flow rate which was determined by the thermal hydraulic design analysis for the core should be estimated to design the PCPs in the fluid system. The pressure loss in the PCS can be calculated by the dimensional analysis of the pipe flow and the head loss coefficient of the components. However, it is insufficient to estimate the pressure loss for 3-dimensional flow phenomena such as the flow path in the reactor with the theoretical dimensional analysis based on experimental data. The purpose of this research is to evaluate the pressure loss of the part of a research reactor vessel. For evaluating the pressure loss, the commercially available CFD computer model, FLUENT, was employed. First, for validating the application of FLUENT to the pressure loss, a simple case was calculated and compared with the Idelchik empirical correlation. Secondly, several cases for the inlet part of a research reactor vessel were estimated by a FLUENT 3- dimensional calculation

  17. Osmotic pressure and virial coefficients of star and comb polymer solutions: dissipative particle dynamics.

    Science.gov (United States)

    Wang, Tzu-Yu; Fang, Che-Ming; Sheng, Yu-Jane; Tsao, Heng-Kwong

    2009-03-28

    The effects of macromolecular architecture on the osmotic pressure pi and virial coefficients (B(2) and B(3)) of star and comb polymers in good solvents are studied by dissipative particle dynamics simulations for both dilute and semiconcentrated regimes. The dependence of the osmotic pressure on polymer concentration is directly calculated by considering two reservoirs separated by a semipermeable, fictitious membrane. Our simulation results show that the ratios A(n+1) identical with B(n+1)/R(g)(3n) are essentially constant and A(2) and A(3) are arm number (f) dependent, where R(g) is zero-density radius of gyration. The value of dimensionless virial ratio g = A(3)/A(2)(2) increases with arm number of stars whereas it is essentially arm number independent for comb polymers. In semiconcentrated regime the scaling relation between osmotic pressure and volume fraction, pi proportional to phi(lambda), still holds for both star and comb polymers. For comb polymers, the exponent lambda is close to lambda(*) (approximately = 2.73 for linear chains) and is independent of the arm number. However, for star polymers, the exponent lambda deviates from lambda(*) and actually grows with increasing the arm number. This may be attributed to the significant ternary interactions near the star core in the many-arm systems.

  18. Assessment of Loss-of-Coolant Effect on Pressurized Heavy Water Reactors

    International Nuclear Information System (INIS)

    Kim, Won Young; Park, Joo Hwan; Kim, Bong Ghi

    2009-01-01

    A CANDU reactor is a heavy-water-moderated, natural uranium fuelled reactor with a pressure tube. The reactor contains a horizontal cylindrical vessel (calandria) and each pressure tube is isolated from the heavy-water moderator in a calandria. This allows the moderator system to be operated of a high-pressure and of a high-temperature coolant in pressure tube. This causes the pressurized liquid coolant in the channel to void and therefore give rise to a reactivity transient in the event of a break or fault in the coolant circuit. In particular, all CANDU reactors are well known to have a positive void reactivity coefficient and thus this phenomenon may lead to a positive feedback, which can cause a large power pulse. We assess the loss-of-coolant effect by coolant void reactivity versus fuel burnup, four factor parameters for fresh fuel and equilibrium fuel, reactivity change due to the change of coolant density and reactivity change in the case of half- and full-core coolant

  19. A study on the stem friction coefficient with differential pressure conditions for the motor operated flexible wedge gate valve

    International Nuclear Information System (INIS)

    Kim, Dae Woong; Park, Sung Keun; Kim, Yang Seok; Lee, Do Hwan

    2008-01-01

    Stem friction coefficient is very important parameter for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient is analyzed, and the bounding value is determined. The hydraulic testing is performed for flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient is not effected in low differential pressure condition, but it is showed different distribution in medium and high differential pressure condition. And the bounding value of closing stroke is higher than that of opening stroke

  20. Analysis of pressure losses in the diffuser of a control valve

    Science.gov (United States)

    Turecký, Petr; Mrózek, Lukáš; Tajč, Ladislav; Kolovratník, Michal

    The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.

  1. Analysis of pressure losses in the diffuser of a control valve

    Directory of Open Access Journals (Sweden)

    Turecký Petr

    2017-01-01

    Full Text Available The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.

  2. Pressure-induced absorption coefficients for radiative transfer calculations in Titan's atmosphere

    Science.gov (United States)

    Courtin, Regis

    1988-01-01

    The semiempirical theory of Birnbaum and Cohen (1976) is used to calculate the FIR pressure-induced absorption (PIA) spectra of N2, CH4, N2 + Ar, N2 + CH4, and N2 + H2 under conditions like those in the Titan troposphere. The results are presented graphically and compared with published data from laboratory measurements of PIA in the same gases and mixtures (Dagg et al., 1986; Dore et al., 1986). Good agreement is obtained, with only a slight underestimation of PIA at 300-400/cm in the case of CH4. The absorption coefficients are presented in tables, and it is suggested that the present findings are of value for evaluating the effects of tropospheric clouds on the Titan FIR spectrum and studying the greenhouse effect near the Titan surface.

  3. Thermodynamics of aqueous electrolytes at various temperatures, pressures, and compositions. [Virial coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Pitzer, K.S.

    1979-09-01

    It is shown that the properties of fully ionized aqueous electrolyte systems can be represented by relatively simple equations over wide ranges of composition. There are only a few systems for which data are available over the full range to fused salt. A simple equation commonly used for nonelectrolytes fits the measured vapor pressure of water reasonably well and further refinements are clearly possible. Over the somewhat more limited composition range up to saturation of typical salts such as NaCl, the equations representing thermodynamic properties with a Debye-Hueckel term plus second and third virial coefficients are very successful and these coefficients are known for nearly 300 electrolytes at room temperature. These same equations effectively predict the properties of mixed electrolytes. A stringent test is offered by the calculation of all of the solubility relationships of the system Na-K-Mg-Ca-Cl-So{sub 4}-H{sub 2}0 and the calculated results of Harvie and Weare show excellent agreement with

  4. Effects of entrance configuration on pressure loss and heat transfer of transitional gas flow in a circular tube

    International Nuclear Information System (INIS)

    Ogawa, Masuro; Kawamura, Hiroshi

    1986-01-01

    Pressure loss and heat transfer of a transitional gas flow are affected significantly by the entrance configuration. The friction factor and the heat transfer coefficient were measured using a circular tube with four different kinds of entrance configurations. The Reynolds number at the transition from laminar to intermittent flow was varied from about 1,940 to 9,120. The intermittency factor was measured for heated and unheated flows ; and the relation between the intermittency and the friction factor or heat transfer coefficient was examined. Several existing correlations were tested and found to correlate with the experimental results fairly well. (author)

  5. The effect of surface roughness on the heat exchange and pressure-drop coefficients

    International Nuclear Information System (INIS)

    Malherbe, J.M.

    1963-02-01

    The effect of various types of roughness on the wall of an axial tube in an annular space of 15-25 mm cooled by an air-flow has been studied in the case of steady turbulence. Roughness of the type 'disrupter of the boundary layer' was set up using triangular threads of 0.2 to 0.4 mm thickness machined in the tube itself, or brass or glass wire wound on a smooth tube. Tests were also carried out using the roughness provided by regularly spaced pyramids 0.4 mm high. The results obtained showed that the heat exchange increased because of the presence of this roughness. A maximum in the heat exchange and pressure-drop coefficients was observed when the pitch equals about eight times the height of the thread. An analytical method has been developed and experiments have been carried out in which the two walls of the annular space were heated in such a way as to transmit unequal heat flows. The region considered is limited to Reynolds's numbers of between 5 X 10 3 and 5 x 10 4 and wall temperatures of under 250 deg C. (author) [fr

  6. Measurements of heat transfer coefficients at low contact pressures for actively cooled bolted armour concepts in Tore Supra

    International Nuclear Information System (INIS)

    Lipa, M.; Chappuis, Ph.; Dufayet, A.

    2000-01-01

    For the future upgrade of inner vessel components (CIEL project) a guard limiter for plasma ramp-up and disruption protection will be installed on the high field side of the vacuum vessel. Among transient heat loads, this structure has to sustain a moderate heat flux in the range of ≤0.5 MW/m 2 during quasi steady state operation (1000 s). A bolted carbon-carbon (C-C) tile is preferred compared with a brazed tile solution due to the expected moderate heat fluxes, costs and the possibility of rapid replacement of individual tiles. Large flat tile assemblies require a sufficient soft and conductive compliant layer enclosed between tile and heat sink in order to avoid thermal contact loss of the assembly during heat loads and therefore minimising the tile surface temperature. The global heat transfer coefficient (H gl ) under vacuum at low contact pressures (0.5-1.5 MPa) between C-C and CuCrZr heat sink substrata has been measured in the experimental device, installation of contact heat transfer measurements (ITTAC), using different compliant materials. It appears that the best compliant layer is a graphite sheet (PAPYEX), compared with copper-felt/foam material. As an example, a H gl number of ∼10 4 W/m 2 K at an average contact pressure of 0.5 MPa has been measured near room temperature between C-C (SEP N11) and CuCrZr substrata using a 0.5-mm thick PAPYEX layer. Thermohydraulic calculations (2D) of the guard limiter design show an expected tile surface temperature of about 550 deg. C in steady state regime for an incident heat flux of 0.5 MW/m 2

  7. Impact of External Pressure on the Heat Transfer Coefficient during Solidification of Al-A356 Alloy

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Ilkhchy, A.Fardi; Moumani, E.

    In this paper the interfacial heat transfer coefficient (IHTC) is correlated to applied external pressure, in which IHTC at the interface between A356 aluminum alloy and metallic mold during the solidification of the casting under different pressures were obtained using the Inverse Heat Conduction...... Problem (IHCP) method. The method covers the expedient of comparing theoretical and experimental thermal histories. Temperature profiles obtained from thermocouples were used in a finite difference heat flow program to estimate the transient heat transfer coefficients. The new simple formula was presented...

  8. Water absorption lines, 931-961 nm - Selected intensities, N2-collision-broadening coefficients, self-broadening coefficients, and pressure shifts in air

    Science.gov (United States)

    Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.

    1982-01-01

    Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.

  9. Comparison of the Friction-Loss Coefficient for the Gap of Two Contact Surfaces and a Crack

    International Nuclear Information System (INIS)

    Nam, Ho Yun; Choi, Byoung Hae; Kim, Jong Bum; Lee, Young Bum

    2011-01-01

    A leak-detection method has been developed by measuring the pressure variation between the inner and outer heat transfer tubes of a double-wall tube steam generator. An experiment was carried out to measure the leak rate in the gap between two surfaces pressed with a hydraulic press in order to simulate the phenomena, and a correlation was determined for the leak rate in a micro gap. However, in the correlation, the gap width and friction coefficient were coupled with the surface roughness, which affects the two parameters. The two parameters were separated using a surface-contact model to develop a correlation for the friction coefficient. The correlation was compared with the existing correlations used for crack analysis. Although the applied ranges of Reynolds numbers were different, the developed correlation for Reynolds numbers of 0.1.0.35 showed similar tendencies to existing correlations used for higher Reynolds numbers

  10. Impedance spectroscopy of PZT ceramics--measuring diffusion coefficients, mixed conduction, and Pb loss.

    Science.gov (United States)

    Donnelly, Niall J; Randall, Clive A

    2012-09-01

    Sintering of lead zirconate titanate (PZT) at high temperatures results in loss of Pb unless an ambient Pb activity is maintained. The tell-tale sign of Pb loss is an increased conductivity, usually manifested in unacceptably high values of tanδ. The conductivity is caused by oxygen vacancies and/or electron holes which are a byproduct of Pb evaporation. In the first part of this paper, it is shown how impedance spectroscopy can be used to separate ionic and electronic conductivity in a properly designed sample by selection of appropriate boundary conditions. Subsequently, impedance is used to probe defect concentrations in PZT during prolonged annealing at 700°C. It is found that oxygen vacancies are generated during annealing in air but the rate of generation actually decreases upon lowering the ambient pO(2). These results are explained by a model of Pb evaporation which, in this case, leads predominantly to oxygen vacancy generation. In principle, this effect could be used to generate a specific vacancy concentration in similar Pb-based oxides.

  11. Heat Transmission Coefficient Measurements in Buildings Utilizing a Heat Loss Measuring Device

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    2013-01-01

    Global energy efficiency can be obtained in two ordinary ways. One way is to improve the energy production and supply side, and the other way is, in general, to reduce the consumption of energy in society. This paper has focus on the latter and especially the consumption of energy for heating...... and cooling our houses. There is a huge energy-saving potential in this area for reducing both the global climate problems as well as economy challenges. Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from...... building envelopes are of great importance in order to reach the Bologna CO2 emission reduction targets. Upgrading of the energy performance of buildings is a topic of huge global interest these years. Not only heating in the temperate and arctic regions are important, but also air conditioning...

  12. Pressure breathing in fighter aircraft for G accelerations and loss of cabin pressurization at altitude--a brief review.

    Science.gov (United States)

    Lauritzsen, Lars P; Pfitzner, John

    2003-04-01

    The purpose of this brief review is to outline the past and present use of pressure breathing, not by patients but by fighter pilots. Of the historical and recent references quoted, most are from aviation-medicine journals that are not often readily available to anesthesiologists. Pressure breathing at moderate levels of airway pressure gave World War II fighter pilots a tactical altitude advantage. With today's fast and highly maneuverable jet fighters, very much higher airway pressures of the order of 8.0 kPa (identical with 60 mmHg) are used. They are used in conjunction with a counterpressure thoracic vest and an anti-G suit for the abdomen and lower body. Pressurization is activated automatically in response to +Gz accelerations, and to a potentially catastrophic loss of cabin pressurization at altitude. During +Gz accelerations, pressure breathing has been shown to maintain cerebral perfusion by raising the systemic arterial pressure, so increasing the level of G-tolerance that is afforded by the use of anti-G suits and seat tilt-back angles alone. This leaves the pilot less reliant on rigorous, and potentially distracting, straining maneuvers. With loss of cabin pressurization at altitude, pressure breathing of 100% oxygen at high airway pressures enables the pilot's alveolar PO(2) to be maintained at a safe level during emergency descent. Introduced in military aviation, pressure breathing for G-tolerance and pressure breathing for altitude presented as concepts that may be of general physiological interest to many anesthesiologists.

  13. Calculation of radiation losses in cylinder symmetric high pressure discharges by means of a digital computer

    International Nuclear Information System (INIS)

    Andriessen, F.J.; Boerman, W.; Holtz, I.F.E.M.

    1973-08-01

    Computer calculations have been made of radiative energy losses in a cylindrically symmetric high pressure discharge. The calculations show that the radiation losses which occur in discharges at pressures of a few atmospheres and central temperatures of about 20000degK when compared with the electrical energy supplied, are only of importance in the neighbourhood of the centre of discharge

  14. Gain and loss mechanisms for neutral species in low pressure fluorocarbon plasmas by infrared spectroscopy

    International Nuclear Information System (INIS)

    Nelson, Caleb T.; Overzet, Lawrence J.; Goeckner, Matthew J.

    2012-01-01

    This article examines the chemical reaction pathways of stable neutral species in fluorocarbon plasmas. Octafluorocyclobutane (c-C 4 F 8 ) inductively coupled plasma discharges were found to primarily produce stable and metastable products downstream from the discharge, including c-C 4 F 8 , C 2 F 4 , C 2 F 6 , CF 4 , C 3 F 8 , C 4 F 10 , C 3 F 6 , and CF 2 . A novel analysis technique allows the estimation of gain and loss rates for neutral species in the steady state as functions of residence time, pressure, and discharge power. The gain and loss rates show that CF 4 , C 2 F 6 , C 3 F 8 , and C 4 F 10 share related gain mechanisms, speculated to occur at the surface. Further analysis confirms that CF 2 is predominantly produced at the chamber walls through electron impact dissociation of C 2 F 4 and lost through gas-phase addition reactions to form C 2 F 4 . Additionally, time-resolved FTIR spectra provide a second-order rate coefficient of 1.8 × 10 −14 cm 3 /s for the gas-phase addition of CF 2 to form C 2 F 4 . Finally, C 2 F 4, which is much more abundant than CF 2 in the discharge, is shown to be dominantly produced through electron impact dissociation of c-C 4 F 8 and lost through either surface or gas-phase addition reactions.

  15. Spatial dispersion effects in spectral line broadening by pressure. I. The Bouguer Law and absorption coefficient

    International Nuclear Information System (INIS)

    Cherkasov, M.R.

    1995-01-01

    Based on the general principles of semiclassical electrodynamics, the Bouguer law is derived, and the expression for the absorption coefficient is obtained, formally including all effects related to the phenomenon of spatial dispersion

  16. The determination of the pressure viscosity coefficient of a lubricant through an accurate film thickness formula and accurate film thickness measurements

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2009-01-01

    The pressure viscosity coefficient is an indispensable property in the EHD lubrication of hard contacts, but often not known. A guess will easily lead to enormous errors in the film thickness. This paper describes a method to deduct this coefficient by adapting the value of the pressure viscosity

  17. Cuttings-liquid frictional pressure loss model for horizontal narrow annular flow with rotating drillpipe

    International Nuclear Information System (INIS)

    Ofei, T N; Irawan, S; Pao, W

    2015-01-01

    During oil and gas drilling operations, frictional pressure loss is experienced as the drilling fluid transports the drilled cuttings from the bottom-hole, through the annulus, to the surface. Estimation of these pressure losses is critical when designing the drilling hydraulic program. Two-phase frictional pressure loss in the annulus is very difficult to predict, and even more complex when there is drillpipe rotation. Accurate prediction will ensure that the correct equivalent circulating density (ECD) is applied in the wellbore to prevent formation fracture, especially in formations with narrow window between the pore pressure and fracture gradient. Few researchers have attempted to propose cuttings-liquid frictional pressure loss models, nevertheless, these models fail when they are applied to narrow wellbores such as in casing- while-drilling and slimhole applications. This study proposes improved cuttings-liquid frictional pressure loss models for narrow horizontal annuli with drillpipe rotation using Dimensional Analysis. Both Newtonian and non-Newtonian fluids were considered. The proposed model constants were fitted by generated data from a full-scale simulation study using ANSYS-CFX. The models showed improvement over existing cuttings-liquid pressure loss correlations in literature. (paper)

  18. Regenerator heat exchanger – calculation of heat recovery efficiency and pressure loss

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per Kvols

    Performance of heat exchangers is determined based on two main parameters: efficiency to exchange / recover heat and pressure loss due to friction between fluid and exchanger surfaces. These two parameters are contradicting each other which mean that the higher is efficiency the higher becomes...... pressure loss. The aim of the optimized design of heat exchanger is to reach the highest or the required heat efficiency and at the same time to keep pressure losses as low as possible keeping total exchanger size within acceptable size. In this report is presented analytical calculation method...... to calculate efficiency and pressure loss in the regenerator heat exchanger with a fixed matrix that will be used in the decentralized ventilation unit combined in the roof window. Moreover, this study presents sensitivity study of regenerator heat exchanger performance, taking into account, such parameters as...

  19. Primary break with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Cordelle, F.; Champ, M.; Pochard, R.

    1988-10-01

    The probabilitic safety assessment of a 900 MW plant has displayed the potential importance, with regard to the risk, of intermediate primary breaks with failure of the high pressure safety injection system. The probability of such sequence is about 10 -6 /plant X year. Therefore, it is necessary to establish: - if this sequence can lead to core melt down, - if clad ruptures can occur. This event must be taken into account to determine the repair time of contaminated systems. For these studies, a three inch equivalent diameter break is considerd, as this is the most sensitive in its category with regard to these phenomena. In addition to the above objectives, the purpose of these studies is to evaluate the sensitivity of the results to the following parameters: - the time limit at which the operator starts cooling down the plant via the steam generators. Two calculations have been made with the RELAP code (1 and 2) and two with the CATHARE code (3 and 4) - the pump trip time. Four calculations have been made with the CATHARE code (5, 6, 7 and 8). In the case of failure of only one high pressure safety injection file, 6 calculations have been made with the CATHARE code, concerning the influence of pump trip time (9, 10, 11, 12, 13 and 14)

  20. Determination of oral mucosal Poisson's ratio and coefficient of friction from in-vivo contact pressure measurements.

    Science.gov (United States)

    Chen, Junning; Suenaga, Hanako; Hogg, Michael; Li, Wei; Swain, Michael; Li, Qing

    2016-01-01

    Despite their considerable importance to biomechanics, there are no existing methods available to directly measure apparent Poisson's ratio and friction coefficient of oral mucosa. This study aimed to develop an inverse procedure to determine these two biomechanical parameters by utilizing in vivo experiment of contact pressure between partial denture and beneath mucosa through nonlinear finite element (FE) analysis and surrogate response surface (RS) modelling technique. First, the in vivo denture-mucosa contact pressure was measured by a tactile electronic sensing sheet. Second, a 3D FE model was constructed based on the patient CT images. Third, a range of apparent Poisson's ratios and the coefficients of friction from literature was considered as the design variables in a series of FE runs for constructing a RS surrogate model. Finally, the discrepancy between computed in silico and measured in vivo results was minimized to identify the best matching Poisson's ratio and coefficient of friction. The established non-invasive methodology was demonstrated effective to identify such biomechanical parameters of oral mucosa and can be potentially used for determining the biomaterial properties of other soft biological tissues.

  1. Loss of cabin pressurization in U.S. Naval aircraft: 1969-90.

    Science.gov (United States)

    Bason, R; Yacavone, D W

    1992-05-01

    During the 22-year period from 1 January 1969 to 31 December 1990, there were 205 reported cases of loss of cabin pressure in US Naval aircraft; 21 were crew-initiated and 184 were deemed accidental. The ambient altitudes varied from 10,000 ft (3048 m) to 40,000 ft. (12192 m). The most common reason for crew-initiated decompression was to clear smoke and fumes from the cockpit/cabin (95%). The most common cause for accidental loss of cabin pressure was mechanical (73.37%), with aircraft structural damage accounting for the remaining 26.63%. Serious physiological problems included 1 pneumothorax, 11 cases of Type I decompression sickness, 23 cases of mild to moderate hypoxia with no loss of consciousness, 18 cases of hypoxia with loss of consciousness, and 3 lost aircraft with 4 fatalities due to incapacitation by hypoxia. In addition, 12 ejections were attributed to loss of cockpit pressure. Nine of the ejections were deliberate and three were accidental, caused by wind blast activation of the face curtain. Three aviators lost their lives following ejection and seven aircraft were lost. While the incidence of loss of cabin pressure in Naval aircraft appears low, it none-the-less presents a definite risk to the aircrew. Lectures on the loss of cabin/cockpit pressurization should continue during indoctrination and refresher physiology training.

  2. On Rotor-Blade Deterioration and Pressure Losses in a Gas-Turbine ...

    African Journals Online (AJOL)

    blade deterioration and pressure losses in a gas-turbine plant. This was achieved ... Rotor-blade deterioration result in 1.2 percent drop in pressure ratio across the compressor, with a corresponding drop in isentropic efficiency from 0.83 to 0.72.

  3. Pressure loss of the annular air-liquid flow in vertical tufes

    Energy Technology Data Exchange (ETDEWEB)

    Schmal, M [Rio de Janeiro Univ. (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia; Cantalino, A [Rio de Janeiro Univ. (Brazil). Dept. de Engenharia Quimica

    1976-01-01

    In this work the pressure loss of the annular air-liquid flow in vertical tubes has been determined. Correlations are presented for the frictional pressure drop. The dimensional analysis and the following fluid systems were used for this determination: air-water, air-alcohol solutions and air-water and surfactants.

  4. Coefficient of Friction Measurements for Thermoplastics and Fibre Composites Under Low Sliding Velocity and High Pressure

    DEFF Research Database (Denmark)

    Poulios, Konstantinos; Svendsen, Gustav Winther; Hiller, Jochen

    2013-01-01

    that friction materials which are untypical for brake applications, like thermoplastics and fibre composites, can offer superior performance in terms of braking torque, wear resistance and cost than typical brake linings. In this paper coefficient of friction measurements for various thermoplastic and fibre......Friction materials for typical brake applications are normally designed considering thermal stability as the major performance criterion. There are, however, brake applications with very limited sliding velocities, where the generated heat is insignificant. In such cases it is possible...... in order to interpret the changes of friction observed during the running-in phase....

  5. A unified view of energetic efficiency in active drag reduction, thrust generation and self-propulsion through a loss coefficient with some applications

    Science.gov (United States)

    Arakeri, Jaywant H.; Shukla, Ratnesh K.

    2013-08-01

    An analysis of the energy budget for the general case of a body translating in a stationary fluid under the action of an external force is used to define a power loss coefficient. This universal definition of power loss coefficient gives a measure of the energy lost in the wake of the translating body and, in general, is applicable to a variety of flow configurations including active drag reduction, self-propulsion and thrust generation. The utility of the power loss coefficient is demonstrated on a model bluff body flow problem concerning a two-dimensional elliptical cylinder in a uniform cross-flow. The upper and lower boundaries of the elliptic cylinder undergo continuous motion due to a prescribed reflectionally symmetric constant tangential surface velocity. It is shown that a decrease in drag resulting from an increase in the strength of tangential surface velocity leads to an initial reduction and eventual rise in the power loss coefficient. A maximum in energetic efficiency is attained for a drag reducing tangential surface velocity which minimizes the power loss coefficient. The effect of the tangential surface velocity on drag reduction and self-propulsion of both bluff and streamlined bodies is explored through a variation in the thickness ratio (ratio of the minor and major axes) of the elliptical cylinders.

  6. Pressure sensor for use in the Loss-of-Fluid-Test (LOFT) reactor

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-07-01

    Tests at temperatures up to 800 0 F and pressures up to 2500 psig were conducted at Hanford Engineering Development Laboratory (HEDL) to qualify an instrument for measurement of fuel-rod pressure in the Loss-of-Fluid-Test (LOFT) reactor. Operational characteristics of the selected pressure transducers are summarized for a series of static, quasi-static, and transient tests conducted for a period of about 700 hours

  7. Evaluation to Mitigate Secondary System Peak Pressure for Loss of Condenser Vacuum Event

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bong Oh; Park, Jong Cheol; Park, Min Soo; Lee, Gyu Cheon; Kim, Shin Whan [KEPCO E and C, Inc., Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, countermeasures to compensate the increased secondary pressure are introduced and evaluated. From the standpoint of the secondary system pressurization, consideration of the PPCS may result in a conservative secondary system peak pressure. The control systems are generally credited for the safety analysis if the analysis produces conservative results. However, in most of all non-loss of coolant accident (non-LOCA) events, the control system helps to mitigate a transient state. Accordingly, the safety analysis of non-LOCA assumes the control systems are in the manual mode of operation. The loss of condenser vacuum event (LOCV) is a typical anticipated operational occurrence (AOO) which results in an increase in primary and secondary system pressure. The pressurizer (PZR) pressure control system (PPCS) will function to reduce the primary system pressure increase during the transient. Therefore, it is assumed to be in manual mode and credit is not taken for its functioning. However, crediting the function of PPCS has been found to be more conservative with regard to the secondary system pressure. This is due to the delay of the reactor trip on high pressurizer pressure (HPP) and results in an increase in secondary pressure.

  8. Vent clearing during a simulated loss-of-coolant accident in a Mark I boiling-water reactor pressure-suppression system

    International Nuclear Information System (INIS)

    Pitts, J.H.; McCauley, E.W.

    1978-01-01

    In this test series, drywell pressurization rate, drywell overpressure, downcomer submergence, and overall vent system loss coefficient were varied to quantify the primary load sensitivities in the pressure suppression system. Extensive tests were conducted on a unique three-dimensional 1/5 scale model of the pressure suppression system a MARK-I BWR. They were focused on the initial or air cleaning phase of a hypothetical loss of coolant accident. As a result of the complete measurement system employed including multiple high speed cameras, the logical interrelationship between measured forces, measured pressures, and the hydrodynamic phenomena observed in high speed photographic pictures were established. The quantitative values from the 1/5 scale experiments can be applied to full scale plants using established scaling laws. (author)

  9. Experimental study of heat exchange coefficients, critical heat flux and charge losses, using water-steam mixtures in turbulent flow in a vertical tube

    International Nuclear Information System (INIS)

    Perroud, P.; De La Harpe, A.; Rebiere, J.

    1960-12-01

    Two stainless steel tubes were used (with diameters of 5 and 10 mm, lengths 400 and 600 mm respectively), heated electrically (50 Hz). The mixture flows from top to bottom. The work was carried out mainly on mixtures of high concentration (x > 0.1), at pressures between 50 and 60 kg/cm 2 , flowing as a liquid film on the walls of the tube with droplets suspended in the central current of steam. By analysis of the heat transfer laws the exchange mechanisms were established, and the conditions under which the critical heat flux may be exceeded without danger of actual burnout were determined. In this way high output concentrations (x s > 0.9) may be obtained. An attempt has been made to find out to what extent existing correlation formulae can be used to account for the phenomena observed. It is shown that those dealing with exchange coefficients can only be applied in a first approximation in cases where exchange by convection is preponderant, and only below the critical flux. The formulae proposed by WAPD and CISE do not give a satisfactory estimation of the critical heat flux, and the essential reasons for this inadequacy are explained. Lastly, the Martinelli and Nelson method may be used to an approximation of 30 per cent for the calculation of charge losses. (author) [fr

  10. High-pressure effects on cooking loss and histological structure of beef muscle

    Science.gov (United States)

    Liu, Anjun; Zhan, Hu; Zheng, Jie; Liu, Dongyue; Jia, Peiqi

    2010-12-01

    In this study, we investigate the effects of high pressures (up to 600 MPa) applied at room temperature for 10 min on beef cooking loss and structure. The data on cooking loss, pH and protein solubility, as well as the electron microscopy, illustrate the changes in cooking loss and structure with high pressure processing (HPP). There is a significant reduction in cooking loss of beef with HPP. When the beef sample is imposed upon by 300 or 400 MPa, the cooking loss reduction is about 12%. Further, the pH of beef is dramatically increased as the pressure increases, and the pH increases by about 5% when imposed upon by 500 MPa. When a high pressure was applied at room temperature, the structure of the beef tissue apparently changed. Muscle fiber fragments gradually became slender and sarcomeres became lengthened. Our data indicated that high-pressure treatment on beef leads to stretching of the muscle fiber and an increase in the water-holding capacity.

  11. Development of a model for Retran-3D for pressure losses at T-junctions

    International Nuclear Information System (INIS)

    Barten, W.; Coddington, P.; Sullivan, J.

    2001-01-01

    For Nuclear Power Plants, both for PWRs and BWRs, there are many instances in normal operation, accidents and transients when it is important to know the pressure drop and quality of the flow, at a flow junction. In this paper two-phase pressure drops in a horizontal T-junction with equal areas are assessed in the case of separating flow using the RETRAN-3D code. Therefore applying the RETRAN-3D code first recoverable pressure drops are calculated for different flow rate ratios, inlet qualities and system pressures for steam-water mixtures. These pressure drops are then compared to analytical expressions by Soliman and Ebadian (1994) developed from the analysis of a wide range of two-phase experimental pressure drop data for equal-sided junctions with horizontal inlet and side branches both for steam-water and air-water flow. With these comparisons the experimental pressure loss is separated into a recoverable part (i.e. that calculated by RETRAN-3D) and an irrecoverable. A model for the irrecoverable pressure losses is derived for the RETRAN-3D code by comparing the RETRAN-3D total momentum equation with the expressions generally used for pressure changes at T-junctions. The results of this model are compared to the experimental data through the expressions of Soliman and Ebadian and are shown to produce very good comparisons particularly for the range of conditions consistent with the experimental data. (author)

  12. Development of a model for Retran-3D for pressure losses at T-junctions

    Energy Technology Data Exchange (ETDEWEB)

    Barten, W.; Coddington, P. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Sullivan, J. [Penn State University, Nuclear Engineering Program (United States)

    2001-07-01

    For Nuclear Power Plants, both for PWRs and BWRs, there are many instances in normal operation, accidents and transients when it is important to know the pressure drop and quality of the flow, at a flow junction. In this paper two-phase pressure drops in a horizontal T-junction with equal areas are assessed in the case of separating flow using the RETRAN-3D code. Therefore applying the RETRAN-3D code first recoverable pressure drops are calculated for different flow rate ratios, inlet qualities and system pressures for steam-water mixtures. These pressure drops are then compared to analytical expressions by Soliman and Ebadian (1994) developed from the analysis of a wide range of two-phase experimental pressure drop data for equal-sided junctions with horizontal inlet and side branches both for steam-water and air-water flow. With these comparisons the experimental pressure loss is separated into a recoverable part (i.e. that calculated by RETRAN-3D) and an irrecoverable. A model for the irrecoverable pressure losses is derived for the RETRAN-3D code by comparing the RETRAN-3D total momentum equation with the expressions generally used for pressure changes at T-junctions. The results of this model are compared to the experimental data through the expressions of Soliman and Ebadian and are shown to produce very good comparisons particularly for the range of conditions consistent with the experimental data. (author)

  13. On designing low pressure loss working spaces for a planar Stirling micromachine

    Science.gov (United States)

    Hachey, M.-A.; Léveillé, É.; Fréchette, L. G.; Formosa, F.

    2015-12-01

    In this paper, research was undertaken with the objective to design low pressure loss working spaces for a Stirling cycle micro heat engine operating from low temperature waste heat. This planar free-piston heat engine is anticipated to operate at the kHz level with mm3 displacement. Given the resonant nature of the free-piston configuration, the complexity of its working gas’ flow geometry and its projected high operating frequency, flow analysis is relatively complex. Design considerations were thus based on fast prototyping and experimentation. Results show that geometrical features, such as a sharp 90° corner between the regenerator and working spaces, are strong contributors to pressure losses. This research culminated into a promising revised working space configuration for engine start-up, as it considerably reduced total pressure losses, more than 80% at Re = 700, from the original design.

  14. Experimental study and modelling of pressure losses during reflooding of a debris beds

    International Nuclear Information System (INIS)

    Clavier, Remi

    2015-01-01

    This work deals with single and two-phase flow pressure losses in porous media. The aim is to improve understanding and modeling of momentum transfer inside particle beds, in relation with nuclear safety issues concerning the reflooding of debris beds during severe nuclear accidents. Indeed, the degradation of the core during such accidents can lead to the collapse of the fuel assemblies, and to the formation of a debris bed, which can be described as a hot porous medium. This thesis is included in a nuclear safety research project on coolability of debris beds during reflooding sequences. An experimental study of single and two-phase cold-flow pressure losses in particle beds is proposed. The geometrical characteristics of the debris and the hydrodynamic conditions are representative of the real case, in terms of granulometry, particle shapes, and flow velocities. The new data constitute an important contribution. In particular, they contain pressure losses and void fraction measurements in two-phase air-water flows with non-zero liquid Reynolds numbers, which did not exist before. Predictive models for pressure losses in single and two-phase flow through particle beds have been established from experimental data. Their structures are based on macroscopic equations obtained from the volume averaging of local conservation equations. Single-phase flow pressure losses can be described by a Darcy-Forchheimer law with a quadratic correction, in terms of filtration velocity, with a better-than-10 % precision. Numerical study of single-phase flows through porous media shows that this correlation is valid for disordered smooth particle beds. Two-phase flow pressure losses are described using a generalized Darcy-Forchheimer structure, involving inertial and cross flow terms. A new model is proposed and compared to the experimental data and to the usual models used in severe accident simulation codes. (author)

  15. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915measuredsamples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rateand heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08. PMID:26624613

  16. Artificial Neural Networks-Based Software for Measuring Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters.

    Science.gov (United States)

    Liu, Zhijian; Liu, Kejun; Li, Hao; Zhang, Xinyu; Jin, Guangya; Cheng, Kewei

    2015-01-01

    Measurements of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, conventional measurement requires expensive detection devices and undergoes a series of complicated procedures. To simplify the measurement and reduce the cost, software based on artificial neural networks for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters was developed. Using multilayer feed-forward neural networks with back-propagation algorithm, we developed and tested our program on the basis of 915 measured samples of water-in-glass evacuated tube solar water heaters. This artificial neural networks-based software program automatically obtained accurate heat collection rate and heat loss coefficient using simply "portable test instruments" acquired parameters, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, angle between tubes and ground and final temperature. Our results show that this software (on both personal computer and Android platforms) is efficient and convenient to predict the heat collection rate and heat loss coefficient due to it slow root mean square errors in prediction. The software now can be downloaded from http://t.cn/RLPKF08.

  17. Extreme learning machine: a new alternative for measuring heat collection rate and heat loss coefficient of water-in-glass evacuated tube solar water heaters.

    Science.gov (United States)

    Liu, Zhijian; Li, Hao; Tang, Xindong; Zhang, Xinyu; Lin, Fan; Cheng, Kewei

    2016-01-01

    Heat collection rate and heat loss coefficient are crucial indicators for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, wasting too much time and manpower. To address this problem, we previously used artificial neural networks and support vector machine to develop precise knowledge-based models for predicting the heat collection rates and heat loss coefficients of water-in-glass evacuated tube solar water heaters, setting the properties measured by "portable test instruments" as the independent variables. A robust software for determination was also developed. However, in previous results, the prediction accuracy of heat loss coefficients can still be improved compared to those of heat collection rates. Also, in practical applications, even a small reduction in root mean square errors (RMSEs) can sometimes significantly improve the evaluation and business processes. As a further study, in this short report, we show that using a novel and fast machine learning algorithm-extreme learning machine can generate better predicted results for heat loss coefficient, which reduces the average RMSEs to 0.67 in testing.

  18. Reducing water losses via intelligent pressure management; Reduzierung von Wasserverlusten durch intelligentes Druckmanagement

    Energy Technology Data Exchange (ETDEWEB)

    Oppinger, Peter [VAG-Armaturen GmbH, Mannheim (Germany). Marketing

    2008-03-15

    Leaks in water pipes and leaking municipal water-transmission and piping systems, particularly in developing and threshold countries account for water-losses of up to 50% of the water supplied by the waterworks. This article examines three different solutions for effective pressure management on the basis of an intelligent control system, by means of which water-losses can be reduced to a stable and economically rational level. (orig.)

  19. Experimental investigation on single-phase pressure losses in nuclear debris beds: Identification of flow regimes and effective diameter

    Energy Technology Data Exchange (ETDEWEB)

    Clavier, R., E-mail: remi.clavier@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN) – PSN-RES/SEREX/LE2M, Cadarache bât. 327, 13115 St Paul-lez-Durance (France); Chikhi, N., E-mail: nourdine.chikhi@irsn.fr [Institut de Radioprotection et de Sûreté Nucléaire (IRSN) – PSN-RES/SEREX/LE2M, Cadarache bât. 327, 13115 St Paul-lez-Durance (France); Fichot, F. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN) – PSN-RES/SAG/LEPC, Cadarache bât. 700, 13115 St Paul-lez-Durance (France); Quintard, M. [Université de Toulouse – INPT – UPS – Institut de Mécanique des Fluides de Toulouse (IMFT), Allée Camille Soula, F-31400 Toulouse (France); CNRS – IMFT, F-31400 Toulouse (France)

    2015-10-15

    Highlights: • Single-phase pressure drops versus flow rates in particle beds are measured. • Conditions are representative of the reflooding of a nuclear fuel debris bed. • Darcy, weak inertial, strong inertial and weak turbulent regimes are observed. • A Darcy–Forchheimer law is found to be a good approximation in this domain. • A predictive correlation is derived from new experimental data. - Abstract: During a severe nuclear power plant accident, the degradation of the reactor core can lead to the formation of debris beds. The main accident management procedure consists in injecting water inside the reactor vessel. Nevertheless, large uncertainties remain regarding the coolability of such debris beds. Motivated by the reduction of these uncertainties, experiments have been conducted on the CALIDE facility in order to investigate single-phase pressure losses in representative debris beds. In this paper, these results are presented and analyzed in order to identify a simple single-phase flow pressure loss correlation for debris-bed-like particle beds in reflooding conditions, which cover Darcean to Weakly Turbulent flow regimes. The first part of this work is dedicated to study macro-scale pressure losses generated by debris-bed-like particle beds, i.e., high sphericity (>80%) particle beds with relatively small size dispersion (from 1 mm to 10 mm). A Darcy–Forchheimer law, involving the sum of a linear term and a quadratic deviation, with respect to filtration velocity, has been found to be relevant to describe this behavior in Darcy, Strong Inertial and Weak Turbulent regimes. It has also been observed that, in a restricted domain (Re = 15 to Re = 30) between Darcy and Weak Inertial regimes, deviation is better described by a cubic term, which corresponds to the so-called Weak Inertial regime. The second part of this work aims at identifying expressions for coefficients of linear and quadratic terms in Darcy–Forchheimer law, in order to obtain a

  20. Estimation on the Pressure Loss of the Conceptual Primary Cooling System and Design of the Primary Cooling Pump for a Research Reactor

    International Nuclear Information System (INIS)

    Seo, Kyoung Woo; Oh, Jae Min; Park, Jong Hark; Chae, Hee Taek; Seo, Jae Kwang; Park, Cheon Tae; Yoon, Ju Hyeon; Lee, Doo Jeong

    2009-01-01

    A new conceptual primary cooling system (PCS) for a research reactor has been designed for an adequate cooling to the reactor core which has various powers ranging from 30MW through 80MW. The developed primary cooling system consisted of decay tanks, pumps, heat exchangers, vacuum breakers, some isolation and check valves, connection piping, and instruments. Because the system flow rate should be determined by the thermal hydraulic design analysis for the core, the heads to design the primary cooling pumps (PCPs) in a PCS will be estimated by the variable system flow rates. The heads of the part of a research reactor vessel was evaluated by the previous study. The various pressure losses of the PCS can be calculated by the dimensional analysis of the pipe flow and the head loss coefficient of the components. The purpose of this research is to estimate the various pressure losses and to design the PCPs

  1. Effects of a hypothetical loss-of-coolant accident on a Mark I Boiling Water Reactor pressure-suppression system

    International Nuclear Information System (INIS)

    Pitts, J.H.; McCauley, E.W.

    1977-01-01

    A loss-of-coolant accident (LOCA) in a boiling-water-reactor (BWR) power plant has never occurred. However, because this type of accident could be particularly severe, it is used as a principal theoretical basis for design. A series of consistent, versatile, and accurate air-water tests that simulate LOCA conditions has been completed on a 1 / 5 -scale Mark I BWR pressure-suppression system. Results from these tests are used to quantify the vertical-loading function and to study the associated fluid dynamics phenomena. Detailed histories of vertical loads on the wetwell are shown. In particular, variation of hydrodynamic-generated vertical loads with changes in drywell-pressurization rate, downcomer submergence, and the vent-line loss coefficient are established. Initial drywell overpressure, which partially preclears the downcomers of water, substantially reduces the peak vertical loads. Scaling relationships, developed from dimensional analysis and verified by bench-top experiments, allow the 1 / 5 -scale results to be applied to a full-scale BWR power plant. This analysis leads to dimensionless groupings that are invariant. These groupings show that, if water is used as the working fluid, the magnitude of the forces in a scaled facility is reduced by the cube of the scale factor and occurs in a time reduced by the square root of the scale factor

  2. Experimental and numerical investigations of microwave return loss of aircraft inlets with low-pressure plasma

    Science.gov (United States)

    Zhang, Yachun; He, Xiang; Chen, Jianping; Chen, Hongqing; Chen, Li; Zhang, Hongchao; Ni, Xiaowu; Lu, Jian; Shen, Zhonghua

    2018-03-01

    The relationships between return losses of the cylindrical inlet and plasma discharge parameters are investigated experimentally and numerically. The return losses are measured using a high dynamic range measurement system and simulated by COMSOL Multiphysics when the frequency band of the microwaves is in the range 1-4 GHz. The profiles of the plasma density are estimated using Epstein and Bessel functions. Results show that the incident microwaves can be absorbed by plasma efficaciously. The maximal return loss can reach -13.84 dB when the microwave frequency is 2.3 GHz. The increase of applied power implies augmentation of the return loss, which behaves conversely for gas pressure. The experimental and numerical results display reasonable agreement on return loss, suggesting that the use of plasma is effective in the radar cross section reduction of aircraft inlets.

  3. Analysis of containment pressure and temperature changes following loss of coolant accident (LOCA)

    International Nuclear Information System (INIS)

    Nguyen Van Thai; Kieu Ngoc Dung

    2015-01-01

    This paper present a preliminary thermal-hydraulics analysis of AP1000 containment following loss of coolant accident events such as double-end cold line break (DECLB) or main steam line break (MSLB) using MELCOR code. A break of this type will produce a rapid depressurization of the reactor pressure vessel (primary system) and release initially high pressure water into the containment followed by a much smaller release of highly superheated steam. The high pressure liquid water will flash and rapidly pressurize the containment building. The performance of passive containment cooling system for steam removal by condensation on large steel containment structure is a major contributing process, controlling the pressure and temperature maximum reached during the accident event. The results are analyzed, discussed and compared with the similar work done by Sandia National Laboratories. (author)

  4. RCS pressure under reduced inventory conditions following a loss of residual heat removal

    International Nuclear Information System (INIS)

    Palmrose, D.E.; Hughes, E.D.; Johnsen, G.W.

    1992-01-01

    The thermal-hydraulic response of a closed-reactor coolant system to loss of residual heat removal (RHR) cooling is investigated. The processes examined include: core coolant boiling and steam generator reflux condensation, pressure increase on the primary side, heat transfer mechanisms on the steam generator primary and secondary sides, and effects of noncondensible gas on heat transfer processes

  5. Biofilter media gas pressure loss as related to media particle size and particle shape

    DEFF Research Database (Denmark)

    Pugliese, Lorenzo; Poulsen, Tjalfe G.; Røjgaard Andreasen, Rune

    2013-01-01

    Pressure loss (ΔP) is a key parameter for estimating biofilter energy consumption. Accurate predictions of ΔP as a function of air velocity (V) are therefore essential, to assess energy consumption and minimize operation costs. This paper investigates the combined impact of medium particle size...

  6. Sensor for measurement of fuel rod gas pressure during loss-of-fluid-tests

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1979-05-01

    Qualification tests have been conducted of a measurement system for determining the pressure of certain fuel rods in the loss-of-fluid-test (LOFT) reactor. Because of physical size (0.35-in. OD by 5.5-in length) and operational characteristics, an eddy current device was selected as the most promising measurement transducer for the application. The sensor must operate at pressure up to 17.2 MPa (2500 psig) and at temperatures up to 800 0 F. During the reactor transient caused by loss of coolant flow, sensor temperature and applied pressure will vary rapidly and significantly. Consequently, qualification tests included subjection of the sensor to rapid depressurization, temperature transients, and blowdowns in an autoclave, as well as to calibrations and various slow temperature cycles

  7. Determination of diffusion coefficients of carbon dioxide in water between 268 and 473 K in a high-pressure capillary optical cell with in situ Raman spectroscopic measurements

    Science.gov (United States)

    Lu, Wanjun; Guo, Huirong; Chou, I.-Ming; Burruss, R.C.; Li, Lanlan

    2013-01-01

    Accurate values of diffusion coefficients for carbon dioxide in water and brine at reservoir conditions are essential to our understanding of transport behavior of carbon dioxide in subsurface pore space. However, the experimental data are limited to conditions at low temperatures and pressures. In this study, diffusive transfer of carbon dioxide in water at pressures up to 45 MPa and temperatures from 268 to 473 K was observed within an optical capillary cell via time-dependent Raman spectroscopy. Diffusion coefficients were estimated by the least-squares method for the measured variations in carbon dioxide concentration in the cell at various sample positions and time. At the constant pressure of 20 MPa, the measured diffusion coefficients of carbon dioxide in water increase with increasing temperature from 268 to 473 K. The relationship between diffusion coefficient of carbon dioxide in water [D(CO2) in m2/s] and temperature (T in K) was derived with Speedy–Angell power-law approach as: D(CO2)=D0[T/Ts-1]m where D0 = 13.942 × 10−9 m2/s, Ts = 227.0 K, and m = 1.7094. At constant temperature, diffusion coefficients of carbon dioxide in water decrease with pressure increase. However, this pressure effect is rather small (within a few percent).

  8. Occupational Noise Exposure, Bilateral High-Frequency Hearing Loss, and Blood Pressure.

    Science.gov (United States)

    Gan, Wen Qi; Mannino, David M

    2017-11-13

    The aim of this study was to investigate the relationships between occupational noise exposure and blood pressure using self-reported occupational exposure and bilateral high-frequency hearing loss. This study included 4548 participants aged 20 to 69 years from the National Health and Nutrition Examination Survey 1999 to 2004. On the basis of self-reported exposure status, participants were divided into the current, former, or never exposed groups. Bilateral high-frequency hearing loss was defined as the average high-frequency hearing threshold at least 25 dB in both ears. The currently exposed participants had slightly increased diastolic blood pressure compared with those never exposed. Among previously exposed participants, those with bilateral high-frequency hearing loss had increased systolic blood pressure, heart rate, and the prevalence of hypertension compared with those with normal high-frequency hearing. Although there were some significant results, the evidence was not consistent to support the associations between occupational noise exposure and blood pressure.

  9. Qualification of a Method to Calculate the Irrecoverable Pressure Loss in High Reynolds Number Piping Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sigg, K. C.; Coffield, R. D.

    2002-09-01

    High Reynolds number test data has recently been reported for both single and multiple piping elbow design configurations at earlier ASME Fluid Engineering Division conferences. The data of these studies ranged up to a Reynolds number of 42 x 10[sup]6 which is significantly greater than that used to establish design correlations before the data was available. Many of the accepted design correlations, based on the lower Reynolds number data, date back as much as fifty years. The new data shows that these earlier correlations are extremely conservative for high Reynolds number applications. Based on the recent high Reynolds number information a new recommended method has been developed for calculating irrecoverable pressure loses in piping systems for design considerations such as establishing pump sizing requirements. This paper describes the recommended design approach and additional testing that has been performed as part of the qualification of the method. This qualification testing determined the irrecoverable pressure loss of a piping configuration that would typify a limiting piping section in a complicated piping network, i.e., multiple, tightly coupled, out-of-plane elbows in series under high Reynolds number flow conditions. The overall pressure loss measurements were then compared to predictions, which used the new methodology to assure that conservative estimates for the pressure loss (of the type used for pump sizing) were obtained. The recommended design methodology, the qualification testing and the comparison between the predictions and the test data are presented. A major conclusion of this study is that the recommended method for calculating irrecoverable pressure loss in piping systems is conservative yet significantly lower than predicted by early design correlations that were based on the extrapolation of low Reynolds number test data.

  10. Vapour pressures, osmotic and activity coefficients for binary mixtures containing (1-ethylpyridinium ethylsulfate + several alcohols) at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gomez, Elena; Dominguez, Angeles; Macedo, Eugenia A.

    2010-01-01

    Osmotic coefficients of binary mixtures containing several primary and secondary alcohols (1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol) and the pyridinium-based ionic liquid 1-ethylpyridinium ethylsulfate were determined at T = 323.15 K using the vapour pressure osmometry technique. From the experimental results, vapour pressure and activity coefficients can be determined. For the correlation of osmotic coefficients, the extended Pitzer model modified by Archer, and the modified NRTL (MNRTL) model were used, obtaining deviations lower than 0.017 and 0.047, respectively. The mean molal activity coefficients and the excess Gibbs free energy for the binary mixtures studied were determined from the parameters obtained with the extended Pitzer model modified by Archer.

  11. Analysis of a small break loss-of-coolant accident of pressurized water reactor by APROS

    Energy Technology Data Exchange (ETDEWEB)

    Al-Falahi, A. [Helsinki Univ. of Technology, Espoo (Finland); Haennine, M. [VTT Energy, Espoo (Finland); Porkholm, K. [IVO International, Ltd., Vantaa (Finland)

    1995-09-01

    The purpose of this paper is to study the capability of APROS (Advanced PROcess Simulator) code to simulate the real plant thermal-hydraulic transient of a Small Break Loss-Of-Coolant Accident (SBLOCA) of Loss-Of-Fluid Test (LOFT) facility. The LOFT is a scaled model of a Pressurized Water Reactor (PWR). This work is a part of a larger validation of the APROS thermal-hydraulic models. The results of SBLOCA transient calculated by APROS showed a reasonable agreement with the measured data.

  12. A new consideration for the heat transfer coefficient and an analysis of the thermal stress of the high-interim pressure turbine casing model

    International Nuclear Information System (INIS)

    Um, Dall Sun

    2004-01-01

    In real design of the high and interim pressure turbine casing, it is one of the important things to figure out its thermal strain exactly. In this paper, with the establishment of the new concept for the heat transfer coefficient of steam that is one of the factors in analysis of the thermal stress for turbine casing, an analysis was done for one of the high and interim pressure turbine casings in operating domestically. The sensitivity analysis of the heat transfer coefficient of steam to the thermal strain of the turbine casing was done with a 2-D simple model. The analysis was also done with switching of the material properties of the turbine casing and resulted in that the thermal strain of the turbine casing was not so sensitive to the heat transfer coefficient of steam. On the basis of this, 3-D analysis of the thermal strain for the high and interim pressure turbine casing was done

  13. Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

    Science.gov (United States)

    Dyverfeldt, Petter; Hope, Michael D; Tseng, Elaine E; Saloner, David

    2013-01-01

    The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equation used to estimate pressure gradients often misclassifies the ventricular overload caused by aortic stenosis. The current gold standard for estimation of irreversible pressure loss is catheterization, but this method is rarely used due to its invasiveness. Post-stenotic pressure loss is largely caused by dissipation of turbulent kinetic energy into heat. Recent developments in magnetic resonance flow imaging permit noninvasive estimation of TKE. The study was approved by the local ethics review board and all subjects gave written informed consent. Three-dimensional cine magnetic resonance flow imaging was used to measure TKE in 18 subjects (4 normal volunteers, 14 patients with aortic stenosis with and without dilation). For each subject, the peak total TKE in the ascending aorta was compared with a pressure loss index. The pressure loss index was based on a previously validated theory relating pressure loss to measures obtainable by echocardiography. The total TKE did not appear to be related to global flow patterns visualized based on magnetic resonance-measured velocity fields. The TKE was significantly higher in patients with aortic stenosis than in normal volunteers (p < 0.001). The peak total TKE in the ascending aorta was strongly correlated to index pressure loss (R(2) = 0.91). Peak total TKE in the ascending aorta correlated strongly with irreversible pressure loss estimated by a well-established method. Direct measurement of TKE by magnetic resonance flow imaging may, with further validation, be used to estimate irreversible pressure loss in aortic stenosis. Copyright © 2013 American

  14. Based on the rainfall system platform raindrops research and analysis of pressure loss

    Science.gov (United States)

    Cao, Gang; Sun, Jian

    2018-01-01

    With the rapid development of China’s military career, land, sea and air force all services and equipment of modern equipment need to be in the rain test, and verify its might suffer during transportation, storage or use a different environment temperature lower water or use underwater, the water is derived from the heavy rain, the wind and rain, sprinkler system, splash water, water wheel, a violent shock waves or use underwater, etcTest the product performance and quality, under the condition of rainfall system platform in the process of development, how to control the raindrops pressure loss becomes the key to whether the system can simulate the real rainfall [1], this paper is according to the rainfall intensity, nozzle flow resistance, meet water flow of rain pressure loss calculation and analysis, and system arrangement of the optimal solution of rainfall is obtained [2].

  15. Computational estimation of logarithm of octanol/air partition coefficients and subcooled vapour pressures for each of 75 chloronaphtalene congeners

    Energy Technology Data Exchange (ETDEWEB)

    Puzyn, T.; Falandysz, J.; Rostkowski, P.; Piliszek, S.; Wilczyniska, A. [Univ. of Gdansk (Poland)

    2004-09-15

    Polychlorinated naphthalenes (PCNs, CNs) are known persistent organic pollutants, contaminating natural ecosystems in effect of technical human activity. Toxic effects induced by individual congers of PCNs are reported elsewhere. Great risk of these chemical compounds is additionally connected with theirs excellent ability to be transported via atmosphere from a source to the remote regions on the Glob. Chloronaphthalene congeners had been found in Arctic regions at significant level in spite of the fact, that they had never been synthesized there, and also thermal processes like municipal waste incineration or domestic heating (other possible sources of PCNs in the environment) were not so intensive there. In 1996 F. Wania and D. Mackay have formulated some empirical rules, which have been very useful in estimation and modeling of environmental transport processes of persistent organic pollutants like PCNs. Two very important physico-chemical parameters in the theory of global distillation and cold condensation are: logarithm of n-octanol/air partition coefficient (log K{sub OA}) and logarithm of subcooled vapour pressure (log P{sub L}). Values of log K{sub OA} and log P{sub L} in standard procedures are determined by means of chromatographic methods. In order to reduce costs and number of experiments, we have proposed simple computational method of estimation log K{sub OA} and log P{sub L}.

  16. Vapour pressures and osmotic coefficients of binary mixtures of 1-ethyl-3-methylimidazolium ethylsulfate and 1-ethyl-3-methylpyridinium ethylsulfate with alcohols at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gonzalez, Begona; Dominguez, Angeles; Macedo, Eugenia A.

    2009-01-01

    Osmotic coefficients of binary mixtures containing alcohols (ethanol, 1-propanol, and 2-propanol) and the ionic liquids 1-ethyl-3-methylimidazolium ethylsulfate and 1-ethyl-3-methylpyridinium ethylsulfate were determined at T = 323.15 K. Vapour pressure and activity coefficients of the studied systems were calculated from experimental data. The extended Pitzer model modified by Archer, and the modified NRTL model (MNRTL) were used to correlate the experimental data, obtaining standard deviations lower than 0.012 and 0.031, respectively. The mean molal activity coefficients and the excess Gibbs free energy of the studied binary mixtures were calculated from the parameters obtained with the extended Pitzer model of Archer.

  17. Loss-of-Fluid Test findings in pressurized water reactor core's thermal-hydraulic behavior

    International Nuclear Information System (INIS)

    Russell, M.

    1983-01-01

    This paper summarizes the pressurized water reactor (PWR) core's thermal-hydraulic behavior findings from experiments performed at the Loss-of-Fluid Test (LOFT) Facility at the Idaho National Engineering Laboratory. The potential impact of these findings on the safety and economics of PWR's generation of electricity is also discussed. Reviews of eight important findings in the core's physical behavior and in experimental methods are presented with supporting evidence

  18. Pressure behavior in nuclear reactor containment following a loss of coolant accident

    Energy Technology Data Exchange (ETDEWEB)

    Khattab, M; Ibrahim, N A; Bedrose, C D [Reactors department, nuclear research center, atomic energy authority, Cairo, (Egypt)

    1995-10-01

    The scenarios of pressure variation following a loss of coolant accident (LOCA) inside the containment of pressurized water reactor (PWR) have been investigated. Critical mass flow rushing out from high pressure leg through pipe break is used to calculate the rate of coolant. The energy added to the containment atmosphere is determined to specify the rate of growth of pressure and temperature. The seniors of small, medium and large LOCA at 2%, 15%, and 25% flow released are investigated. Safety water spray system is initiated as the pressure reaches the containment design safety limit at about 3 bar to depressurise and to cooldown the system and thereby to reduce the concentration of radioactivity release in the containment atmosphere. The pressure response before and after operation of safety spray system is predicted in each size of LOCA using a typical design of westinghouse PWR system. The heat removal from the containment environment is rejected into the sump by drop-wise condensation mechanism. The effect of initial droplets diameters injected from the nozzles of the spray system is investigated. The results show that the droplet diameter of 3 mm gives best performance. 6 figs.

  19. Pressure behavior in nuclear reactor containment following a loss of coolant accident

    International Nuclear Information System (INIS)

    Khattab, M.; Ibrahim, N.A.; Bedrose, C.D.

    1995-01-01

    The scenarios of pressure variation following a loss of coolant accident (LOCA) inside the containment of pressurized water reactor (PWR) have been investigated. Critical mass flow rushing out from high pressure leg through pipe break is used to calculate the rate of coolant. The energy added to the containment atmosphere is determined to specify the rate of growth of pressure and temperature. The seniors of small, medium and large LOCA at 2%, 15%, and 25% flow released are investigated. Safety water spray system is initiated as the pressure reaches the containment design safety limit at about 3 bar to depressurise and to cooldown the system and thereby to reduce the concentration of radioactivity release in the containment atmosphere. The pressure response before and after operation of safety spray system is predicted in each size of LOCA using a typical design of westinghouse PWR system. The heat removal from the containment environment is rejected into the sump by drop-wise condensation mechanism. The effect of initial droplets diameters injected from the nozzles of the spray system is investigated. The results show that the droplet diameter of 3 mm gives best performance. 6 figs

  20. Pressure behaviour in a nuclear reactor containment following a loss of coolant accident

    International Nuclear Information System (INIS)

    KHattab, M.S.; Ibrahim, N.A.; Bedrose, S.D.

    1994-01-01

    The scenarios of pressure variation following a loss of coolant accident (LOCA) inside the containment of pressurized water reactor (PWR) have been investigated. Critical mass flow rushing out from high pressure leg through pipe break, is used to calculate the rate of coolant. The energy added to the containment atmosphere is determined to specify the rate of growth of pressure and temperature. The scenarios of small, medium and large LOCA at 2%, 15% and 25% flow released are investigated. Safety water spray system is initiated as the pressure reaches the containment design safety limit at about 3 bar to depressurise and to cooldown the system and thereby to reduce the concentration of radioactivity release in the containment atmosphere. The pressure response before and after operation of safety spray system is predicted in each size of LOCA using a typical design of westinghouse PWR system. The results of large LOCA showed good agreement with westinghouse calculations of the same design. The heat removal from the containment environment is rejected into the sump by drop-wise condensation mechanism. The effect of initial droplets diameters injected from the nozzles of the spray system is investigated. The results show that the droplet diameter of 3 mm gives best performance. 6 figs., 1 tab

  1. Simultaneous effects of hydrostatic pressure and spin–orbit coupling on linear and nonlinear intraband optical absorption coefficients in a GaAs quantum ring

    International Nuclear Information System (INIS)

    Mughnetsyan, V.N.; Manaselyan, A.Kh.; Barseghyan, M.G.; Kirakosyan, A.A.

    2013-01-01

    In this paper the simultaneous effect of hydrostatic pressure and Rashba spin–orbit interaction on intraband linear and nonlinear light absorption has been investigated in cylindrical quantum ring. The one electron energy spectrum has been found using the effective mass approximation and diagonalization procedure. We have found that the Rashba interaction can lead both to the blue- or to the red-shift of the absorption spectrum depending on the transitions character, while the only red-shift is observed due to the hydrostatic pressure. - Highlights: ► The effects of hydrostatic pressure and spin–orbit coupling are investigated for quantum ring. ► The non-linear absorption coefficient is calculated. ► The hydrostatic pressure leads to the decrease in the absorption coefficient. ► Spin–orbit coupling weakens some transitions and strengthens others.

  2. Non-adiabatic pressure loss boundary condition for modelling turbocharger turbine pulsating flow

    International Nuclear Information System (INIS)

    Chiong, M.S.; Rajoo, S.; Romagnoli, A.; Costall, A.W.; Martinez-Botas, R.F.

    2015-01-01

    Highlights: • Bespoke non-adiabatic pressure loss boundary for pulse flow turbine modelling. • Predictions show convincing results against experimental and literature data. • Predicted pulse pressure propagation is in good agreement with literature data. • New methodology is time efficient and requires minimal geometrical inputs. - Abstract: This paper presents a simplified methodology of pulse flow turbine modelling, as an alternative over the meanline integrated methodology outlined in previous work, in order to make its application to engine cycle simulation codes much more straight forward. This is enabled through the development of a bespoke non-adiabatic pressure loss boundary to represent the turbine rotor. In this paper, turbocharger turbine pulse flow performance predictions are presented along with a comparison of computation duration against the previously established integrated meanline method. Plots of prediction deviation indicate that the mass flow rate and actual power predictions from both methods are highly comparable and are reasonably close to experimental data. However, the new boundary condition required significantly lower computational time and rotor geometrical inputs. In addition, the pressure wave propagation in this simplified unsteady turbine model at different pulse frequencies has also been found to be in agreement with data from the literature, thereby supporting the confidence in its ability to simulate the wave action encountered in turbine pulse flow operation

  3. Numerical prediction of pressure loss of fluid in a T-junction

    Energy Technology Data Exchange (ETDEWEB)

    Abdulwahhab, Mohammed; Kumar Injeti, Niranjan [Department of Marin Engineering, Andhra University, AP (India); Fahad Dakhil, Sadoun [Department of Fuel and Energy, Basrah Technical College (Iraq)

    2013-07-01

    This work presents a prediction of pressure loss of fluid with turbulent incompressible flow through a 90° tee junction was carried out and compared with analytical and experimental results. One turbulence model was used in the numerical simulations: {kappa}-{epsilon} model for two different values of area ratio between the main pipe and the branch pipe were 1.0 and 4.0, and flow rate ratios. The continuity, momentum and energy equations were discredited by means of a finite volume technique and the SIMPLE algorithm scheme was applied to link the pressure and velocity fields inside the domain. A three dimensional steady state flow was solving by using CFX 5 code ANSYS FLUENT13. The effect of the flow rate ratio q (ratio between the flow rate in the branch and outlet pipes) on pressure drop and velocity profile was predicted at different Reynolds numbers. The results show that increasing the flow rate ratio the pressure and total energy losses increase because the presence of recirculation and the strong streamline curvature.

  4. Interfacing systems loss of coolant accident (ISLOCA) pressure capacity methodology and Davis-Besse results

    International Nuclear Information System (INIS)

    Wesley, D.A.

    1991-01-01

    A loss of coolant accident resulting from the overpressurization by reactor coolant fluid of a system designed for low-pressure, low-temperature service has been identified as a potential contributor to nuclear power plant risk. In this paper, the methodology developed to assess the probability of failure as a function of internal pressure is presented, and sample results developed for the controlling failure modes and locations of four fluid systems at the Davis-Besse Plant are shown. Included in this evaluation are the tanks, heat exchangers, filters, pumps, valves, and flanged connections for each system. The variability in the probability of failure is included, and the estimated leak rates or leak areas are given for the controlling modes of failure. For this evaluation, all failures are based on quasistatic pressures since the probability of dynamic effects resulting from such causes as water hammer have been initially judged to be negligible for the Davis-Besse plant ISLOCA

  5. Consideration of the loss of activity in the soil for large transfer coefficients in the food chain

    International Nuclear Information System (INIS)

    Brenk, H.D.; Vogt, K.J.

    1978-01-01

    The studies have shown that in the case of large transfer coefficients there will result a considerable overestimation of the ingestion dose if nonradioactive depletion effects are neglected. This overestimation may, depending on nuclide, vegetation and transfer coefficient, amount to two orders of magnitude. There will result e.g. for the bone exposure of a grown-up person, caused by 90 Sr taken up by the consumption of root vegetables, a dose overestimation up to a factor of 50. For the dose to the kidneys of adults by 137 Cs through consumption of beef there will result an overestimation by a factor of up to 60. And for 129 I there will be obtained an infant thyroid dose from the pasture-cow-milk pathway being too large by a factor of up to 100. In order to be able to cover these cases by a sufficiently generalized formalism, too, it appears necessary therefore to modify or extend the 'Allgemeine Berechnungsgrundlagen' (German reg. guide for evaluating the exposure from environmental contamination) in the manner proposed in the paper. (orig./HP) 891 HP/orig.- 892 MB [de

  6. The determination of the pressure-viscosity coefficient of a lubricant through an accurate film thickness formula and accurate film thickness measurements : part 2 : high L values

    NARCIS (Netherlands)

    Leeuwen, van H.J.

    2011-01-01

    The pressure-viscosity coefficient of a traction fluid is determined by fitting calculation results on accurate film thickness measurements, obtained at different speeds, loads, and temperatures. Through experiments, covering a range of 5.6

  7. Experimental investigation of MHD pressure losses in a mock-up of a liquid metal blanket

    Science.gov (United States)

    Mistrangelo, C.; Bühler, L.; Brinkmann, H.-J.

    2018-03-01

    Experiments have been performed to investigate the influence of a magnetic field on liquid metal flows in a scaled mock-up of a helium cooled lead lithium (HCLL) blanket. During the experiments pressure differences between points on the mock-up have been recorded for various values of flow rate and magnitude of the imposed magnetic field. The main contributions to the total pressure drop in the test-section have been identified as a function of characteristic flow parameters. For sufficiently strong magnetic fields the non-dimensional pressure losses are practically independent on the flow rate, namely inertia forces become negligible. Previous experiments on MHD flows in a simplified test-section for a HCLL blanket showed that the main contributions to the total pressure drop in a blanket module originate from the flow in the distributing and collecting manifolds. The new experiments confirm that the largest pressure drops occur along manifolds and near the first wall of the blanket module, where the liquid metal passes through small openings in the stiffening plates separating two breeder units. Moreover, the experimental data shows that with the present manifold design the flow does not distribute homogeneously among the 8 stacked boxes that form the breeding zone.

  8. Vapor pressures, osmotic and activity coefficients for (LiBr + acetonitrile) between the temperatures (298.15 and 343.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Nasirzadeh, Karamat E-mail: karamat.nasirzadeh@chemie.uni-regensburg.de; Neueder, Roland; Kunz, Werner

    2004-06-01

    Precise vapor pressure data for pure acetonitrile and (LiBr + acetonitrile) are given for temperatures ranging from T=(298.15 to 343.15) K. The molality range is from m=(0.0579 to 0.8298) mol {center_dot} kg{sup -1}. The osmotic coefficients are calculated by taking into account the second virial coefficient of acetonitrile. The parameters of the extended Pitzer ion interaction model of Archer and the mole fraction-based thermodynamic model of Clegg-Pitzer are evaluated. These models accurately reproduce the available osmotic coefficients. The parameters of the extended Pitzer ion interaction model of Archer are used to calculate the mean molal activity coefficients.

  9. On the transient pressure build-up in the full pressure safety shell of watercooled nuclear reactors after a loss of coolant accident

    International Nuclear Information System (INIS)

    Mansfeld, G.

    1979-08-01

    The thermo-and fluid-dynamic processes in a multichamber full pressure safety containment during a loss of coolant accident have been investigated. Comparison of the calculations carried out with the computer programs, in which ZOCO VI was used as being representative of similar programs, with the experimental results pointed out discrepancies in the determination of time dependent pressure, pressure difference and temperature curves. This led to the development of a new theoretical model and a program COFLOW which pays particular attention to the fluid dynamic processes in the initial phase of a loss of coolant accident. It can also be used to determine the maximum containment pressure towards the end of a loss of coolant accident. Comparison of the COFLOW results with experiments has shown that COFLOW provides a model and a procedure by which the physical processes in a multichamber full pressure safety containment can be simulated satisfactorily

  10. Electromagnetic force effect on pressure drop and coupling loss of cable in conduit conductor

    International Nuclear Information System (INIS)

    Hamada, Kazuya; Takahashi, Yoshikazu; Matsui, Kunihiro; Kato, Takashi; Okuno, Kiyoshi

    2002-01-01

    In the Engineering Design Activities of the International Thermonuclear Experimental Reactor (ITER), a Central Solenoid Model Coil (CSMC) and a CS Insert Coil (CSIC) have been tested successfully. The CSIC conductor consists of 1,152 superconducting strands bundled on a central cooling channel. As interesting phenomena in the CSIC experiment, it was observed that a pressure drop of the CSIC decreased by about 12% during a current-carrying operation at 40 kA, and coupling losses indicated an operating current dependence. It is considered as a hypothesis that an electromagnetic force causes a compressive deformation of superconducting cable in a jacket and that new flow path was then generated between cable and jacket. Therefore it is also considered that the decreasing of contact resistance between strands as a result of the electromagnetic force derives an increase of coupling losses in the conductor. A pressure drop calculation model with a gap generated by electromagnetic force is constructed. The gap is estimated to be about 1.4 mm at nominal operating conditions (13 T, 44.3 kA). From this calculation, a void fraction as a function of electromagnetic force is evaluated during the current-carrying operation of CSIC. The coupling time constant (nτ c ) as a function of void fraction is then calculated from the coupling loss measurement result during the pulsed operation of CSMC and CSIC. The evaluated nτ c is about 24 ms and is close to nτ c of 20-30 ms of a heat treated short sample having a history of exposure to the electromagnetic force. We used the evaluated nτ c as a function of electromagnetic force to calculate the coupling losses, which varied from 24 ms to about 50 ms during pulsed current operation. These results show a good agreement with measured coupling losses, depending on coil current. To reduce the possibility of strand damage as a result of cable movement, we also here proposed that the void fraction of real ITER conductor should be smaller

  11. High-pressure (vapour + liquid) equilibria for ternary systems composed by {(E)-2-hexenal or hexanal + carbon dioxide + water}: Partition coefficient measurement

    International Nuclear Information System (INIS)

    Bejarano, Arturo; López, Pablo I.; Valle, José M. del; Fuente, Juan C. de la

    2015-01-01

    Highlights: • A new apparatus based on a static–analytic method was assembled in this work. • This work reports high-pressure VLE data of (E)-2-hexenal or hexanal + CO 2 + water. • Data includes (CO 2 + water) partition coefficients of (E)-2-hexenal and hexanal. • High separation factors from water (∼10 4 ) were found especially for (E)-2-hexenal. • The data were obtained at T = (313, 323, and 333) K and pressures from (8 to 19) MPa. - Abstract: A new apparatus based on a static–analytic method assembled in this work was utilised to perform high-pressure (vapour + liquid) equilibria measurements of aqueous ternary systems. This work includes values of isothermal partition coefficients between CO 2 and water of two apple aroma constituents, (E)-2-hexenal and hexanal. Additionally, this work reports new experimental (vapour + liquid) equilibria measurements for the ternary systems (CO 2 + (E)-2-hexenal + water) and (CO 2 + hexanal + water), at fixed liquid phase composition (600 mg · kg −1 ), at temperatures of (313, 323 and 333) K and at pressures from (8 to 19) MPa. Vapour liquid interphase was checked and monitored visually for all the systems studied in this work. No liquid immiscibility was observed at the composition, temperatures and pressures studied. In order to suggest reasonable operation conditions for fractionation of aromas with dense carbon dioxide, partition coefficients of the aroma compounds between CO 2 and water along with their separation factors from water were calculated. Partition coefficients of (E)-2-hexenal between CO 2 and water were in the range of (6 to 91) and where found to be near six times higher than those of hexanal (9 to 17). Very high separation factors from water were observed (∼10 4 ) especially for (E)-2-hexenal. The highest separation factor, for both compounds, was found at a temperature of 313 K and pressures from (12 to 14) MPa

  12. Effect of a Modest Weight Loss in Normalizing Blood Pressure in Obese Subjects on Antihypertensive Drugs

    Directory of Open Access Journals (Sweden)

    Luisa Gilardini

    2016-07-01

    Full Text Available Objective: To assess the effect of a lifestyle intervention in lowering/normalizing blood pressure (BP levels in hypertensive (controlled or not obese patients. Methods: In this prospective observational study, 490 obese hypertensive patients, 389 controlled (BP Results: 18.9% of CH and 20.0% of UH were on ≥ 3 antihypertensive drugs. Weight change (average -4.9 ± 2.7% was independent of the antihypertensive drugs employed. Systolic BP (SBP decreased by 23 mm Hg and diastolic BP (DBP by 9 mm Hg, in patients with UH most of whom (89% normalized BP levels (in 49% after a weight loss Conclusion: Lifestyle interventions are useful for all obese hypertensive patients in most of whom a modest weight loss is sufficient to normalize BP levels avoiding the aggressive use of multiple antihypertensive drugs.

  13. Study on severe accident induced by large break loss of coolant accident for pressureized water reactor

    International Nuclear Information System (INIS)

    Zhang Longfei; Zhang Dafa; Wang Shaoming

    2007-01-01

    Using the best estimate computer code SCDAP/RELAP5/MOD3.2 and taking US Westinghouse corporation Surry nuclear power plant as the reference object, a typical three-loop pressurized water reactor severe accident calculation model was established and 25 cm large break loss of coolant accident (LBLOCA) in cold and hot leg of primary loop induced core melt accident was analyzed. The calculated results show that core melt progression is fast and most of the core material melt and relocated to the lower plenum. The lower head of reactor pressure vessel failed at an early time and the cold leg break is more severe than the hot leg break in primary loop during LBLOCA. (authors)

  14. Single phase and two-phase flow pressure losses through restrictions, expansions and inserts

    International Nuclear Information System (INIS)

    Glenat, P.; Solignac, P.

    1984-11-01

    We give a selection of methods to predict pressure losses through retrictions, expansions and inserts. In single phase flow, we give the classical method based on the one-dimensional momentum and mass balances. In two-phase flow, we propose the method given by Harshe et al. and an empirical approach suggested by Chisholm. We notice the distinction between long and short inserts depends upon wether or not the vena contracta lies within insert. Finally, we propose three correlations to calculate void fraction through the singularities which have been considered [fr

  15. Numerical prediction of pressure loss of fluid in a T-junction

    OpenAIRE

    Mohammed Abdulwahhab, Niranjan Kumar Injeti, Sadoun Fahad Dakhi

    2013-01-01

    This work presents a prediction of pressure loss of fluid with turbulent incompressible flow through a 90° tee junction was carried out and compared with analytical and experimental results. One turbulence model was used in the numerical simulations: k-ε model for two different values of area ratio between the main pipe and the branch pipe were 1.0 and 4.0, and flow rate ratios. The continuity, momentum and energy equations were discredited by means of a finite volume technique and the SIMPLE...

  16. Drag with external and pressure drop with internal flows: a new and unifying look at losses in the flow field based on the second law of thermodynamics

    International Nuclear Information System (INIS)

    Herwig, Heinz; Schmandt, Bastian

    2013-01-01

    Internal and external flows are characterized by friction factors and drag coefficients, respectively. Their definitions are based on pressure drop and drag force and thus are very different in character. From a thermodynamics point of view in both cases dissipation occurs which can uniformly be related to the entropy generation in the flow field. Therefore we suggest to account for losses in the flow field by friction factors and drag coefficients that are based on the overall entropy generation due to the dissipation in the internal and external flow fields. This second law analysis (SLA) has been applied to internal flows in many studies already. Examples of this flow category are given together with new cases of external flows, also treated by the general SLA-approach. (paper)

  17. Impact of pressure losses in small-sized parabolic-trough collectors for direct steam generation

    International Nuclear Information System (INIS)

    Lobón, David H.; Valenzuela, Loreto

    2013-01-01

    Using PTC (parabolic-trough solar collectors) for industrial thermal processes in the temperature range up to 300 °C is not new, but in recent years there is a boosted interest in this type of concentrating solar technology. One of the problems that arise when designing PTC solar fields is how to deal with the pressure losses which are critical when producing saturated steam directly in the collectors. Depending on the characteristics of the collector, mainly on the receiver diameter, and on the nominal process conditions defined, a solar field configuration can be feasible or not. This paper presents a sensitivity analysis done using a software tool developed to study the thermo-hydraulic behaviour of PTC systems using water-steam as heat transfer fluid. In the case study presented, a small-sized PTC designed for industrial process heat applications is considered, which has a focal length of 0.2 m, an aperture area of 2 m 2 , and its receiver pipe has an inner diameter of 15 mm. Varied process conditions are inlet water pressure, temperature, and mass flow rate, solar irradiance and incidence angle of solar radiation. Results show that working pressure definition is particularly critical to make feasible or not the direct steam generation in solar collectors. - Highlights: • DSG (Direct steam generation) in small-sized parabolic-trough collectors. • Thermo-hydraulic sensitivity analysis. • Influence of working pressure and receiver geometry in DSG process

  18. Computational evaluation of the constraint loss on the fracture toughness of reactor pressure vessel steels

    International Nuclear Information System (INIS)

    Serrano Garcia, M.

    2007-01-01

    The Master Curve approach is included on the ASME Code through some Code Cases to assess the reactor pressure vessel integrity. However, the margin definition to be added is not defined as is the margin to be added when the Master Curve reference temperature T 0 is obtained by testing pre-cracked Charpy specimens. The reason is that the T 0 value obtained with this specimen geometry is less conservative than the value obtained by testing compact tension specimens possible due to a loss of constraint. The two parameter fracture mechanics, considered as an extension of the classical fracture mechanics, coupled to a micromechanical fracture models is a valuable tool to assess the effect of constraint loss on fracture toughness. The definition of a parameter able to connect the fracture toughens value to the constraint level on the crack tip will allow to quantify margin to be added to the T 0 value when this value is obtained testing the pre-cracked Charpy specimens included in the surveillance capsule of the reactor pressure vessel. The Nuclear Regulatory Commission (NRC) define on the To value obtained by testing compact tension specimens and ben specimens (as pre-cracked Charpy are) bias. the NRC do not approved any of the direct applications of the Master Curve the reactor pressure vessel integrity assessment until this bias will be quantified in a reliable way. the inclusion of the bias on the integrity assessment is done through a margin to be added. In this thesis the bias is demonstrated an quantified empirical and numerically and a generic value is suggested for reactor pressure vessel materials, so that it can be used as a margin to be added to the T 0 value obtained by testing the Charpy specimens included in the surveillance capsules. (Author) 111 ref

  19. Loss of Akap1 Exacerbates Pressure Overload-Induced Cardiac Hypertrophy and Heart Failure

    Directory of Open Access Journals (Sweden)

    Gabriele G. Schiattarella

    2018-05-01

    Full Text Available Left ventricular hypertrophy (LVH is a major contributor to the development of heart failure (HF. Alterations in cyclic adenosine monophosphate (cAMP-dependent signaling pathways participate in cardiomyocyte hypertrophy and mitochondrial dysfunction occurring in LVH and HF. cAMP signals are received and integrated by a family of cAMP-dependent protein kinase A (PKA anchor proteins (AKAPs, tethering PKA to discrete cellular locations. AKAPs encoded by the Akap1 gene (mitoAKAPs promote PKA mitochondrial targeting, regulating mitochondrial structure and function, reactive oxygen species production, and cell survival. To determine the role of mitoAKAPs in LVH development, in the present investigation, mice with global genetic deletion of Akap1 (Akap1-/-, Akap1 heterozygous (Akap1+/-, and their wild-type (wt littermates underwent transverse aortic constriction (TAC or SHAM procedure for 1 week. In wt mice, pressure overload induced the downregulation of AKAP121, the major cardiac mitoAKAP. Compared to wt, Akap1-/- mice did not display basal alterations in cardiac structure or function and cardiomyocyte size or fibrosis. However, loss of Akap1 exacerbated LVH and cardiomyocyte hypertrophy induced by pressure overload and accelerated the progression toward HF in TAC mice, and these changes were not observed upon prevention of AKAP121 degradation in seven in absentia homolog 2 (Siah2 knockout mice (Siah2-/-. Loss of Akap1 was also associated to a significant increase in cardiac apoptosis as well as lack of activation of Akt signaling after pressure overload. Taken together, these results demonstrate that in vivo genetic deletion of Akap1 enhances LVH development and accelerates pressure overload-induced cardiac dysfunction, pointing at Akap1 as a novel repressor of pathological LVH. These results confirm and extend the important role of mitoAKAPs in cardiac response to stress.

  20. Loss of Akap1 Exacerbates Pressure Overload-Induced Cardiac Hypertrophy and Heart Failure.

    Science.gov (United States)

    Schiattarella, Gabriele G; Boccella, Nicola; Paolillo, Roberta; Cattaneo, Fabio; Trimarco, Valentina; Franzone, Anna; D'Apice, Stefania; Giugliano, Giuseppe; Rinaldi, Laura; Borzacchiello, Domenica; Gentile, Alessandra; Lombardi, Assunta; Feliciello, Antonio; Esposito, Giovanni; Perrino, Cinzia

    2018-01-01

    Left ventricular hypertrophy (LVH) is a major contributor to the development of heart failure (HF). Alterations in cyclic adenosine monophosphate (cAMP)-dependent signaling pathways participate in cardiomyocyte hypertrophy and mitochondrial dysfunction occurring in LVH and HF. cAMP signals are received and integrated by a family of cAMP-dependent protein kinase A (PKA) anchor proteins (AKAPs), tethering PKA to discrete cellular locations. AKAPs encoded by the Akap1 gene (mitoAKAPs) promote PKA mitochondrial targeting, regulating mitochondrial structure and function, reactive oxygen species production, and cell survival. To determine the role of mitoAKAPs in LVH development, in the present investigation, mice with global genetic deletion of Akap1 ( Akap1 -/- ), Akap1 heterozygous ( Akap1 +/- ), and their wild-type ( wt ) littermates underwent transverse aortic constriction (TAC) or SHAM procedure for 1 week. In wt mice, pressure overload induced the downregulation of AKAP121, the major cardiac mitoAKAP. Compared to wt, Akap1 -/- mice did not display basal alterations in cardiac structure or function and cardiomyocyte size or fibrosis. However, loss of Akap1 exacerbated LVH and cardiomyocyte hypertrophy induced by pressure overload and accelerated the progression toward HF in TAC mice, and these changes were not observed upon prevention of AKAP121 degradation in seven in absentia homolog 2 ( Siah2 ) knockout mice ( Siah2 -/- ). Loss of Akap1 was also associated to a significant increase in cardiac apoptosis as well as lack of activation of Akt signaling after pressure overload. Taken together, these results demonstrate that in vivo genetic deletion of Akap1 enhances LVH development and accelerates pressure overload-induced cardiac dysfunction, pointing at Akap1 as a novel repressor of pathological LVH. These results confirm and extend the important role of mitoAKAPs in cardiac response to stress.

  1. CFD Modeling of the Multipurpose Hydrogen Test Bed (MHTB) Self-Pressurization and Spray Bar Mixing Experiments in Normal Gravity: Effect of the Accommodation Coefficient on the Tank Pressure

    Science.gov (United States)

    Kartuzova, Olga; Kassemi, Mohammad

    2015-01-01

    A CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank is utilized in this paper to model the MHTB self-pressurization experiment. The kinetics-based Schrage equation is used to account for the evaporative and condensi ng interfacial mass flows in this model. The effect of the accommodation coefficient for calculating the interfacial mass transfer rate on the tank pressure during tank selfpressurization is studied. The values of the accommodation coefficient which were considered in this study vary from 1.0e-3 to 1.0e-1 for the explicit VOF model and from 1.0e-4 to 1.0e-3 for the implicit VOF model. The ullage pressure evolutions are compared against experimental data. A CFD model for controlling pressure in cryogenic storage tanks by spraying cold liquid into the ullage is also presented. The Euler-Lagrange approach is utilized for tracking the spray droplets and for modeling the interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet-ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux, as well as droplets trajectories, size distribution and temperatures predicted by the model are presented. The ul lage pressure and vapor temperature evolutions are compared with experimental data obtained from the MHTB spray bar mixing experiment. The effect of the accommodation coefficient for calculating the interfacial and droplet mass transfer rates on the tank pressure during mixing of the vapor using spray is studied. The values used for the accommodation coefficient at the interface vary from 1.0e-5 to 1.0e-2. The droplet accommodation coefficient values vary from 2.0e-6 to 1.0e-4.

  2. Application of modified export coefficient method on the load estimation of non-point source nitrogen and phosphorus pollution of soil and water loss in semiarid regions.

    Science.gov (United States)

    Wu, Lei; Gao, Jian-en; Ma, Xiao-yi; Li, Dan

    2015-07-01

    Chinese Loess Plateau is considered as one of the most serious soil loss regions in the world, its annual sediment output accounts for 90 % of the total sediment loads of the Yellow River, and most of the Loess Plateau has a very typical characteristic of "soil and water flow together", and water flow in this area performs with a high sand content. Serious soil loss results in nitrogen and phosphorus loss of soil. Special processes of water and soil in the Loess Plateau lead to the loss mechanisms of water, sediment, nitrogen, and phosphorus are different from each other, which are greatly different from other areas of China. In this study, the modified export coefficient method considering the rainfall erosivity factor was proposed to simulate and evaluate non-point source (NPS) nitrogen and phosphorus loss load caused by soil and water loss in the Yanhe River basin of the hilly and gully area, Loess Plateau. The results indicate that (1) compared with the traditional export coefficient method, annual differences of NPS total nitrogen (TN) and total phosphorus (TP) load after considering the rainfall erosivity factor are obvious; it is more in line with the general law of NPS pollution formation in a watershed, and it can reflect the annual variability of NPS pollution more accurately. (2) Under the traditional and modified conditions, annual changes of NPS TN and TP load in four counties (districts) took on the similar trends from 1999 to 2008; the load emission intensity not only is closely related to rainfall intensity but also to the regional distribution of land use and other pollution sources. (3) The output structure, source composition, and contribution rate of NPS pollution load under the modified method are basically the same with the traditional method. The average output structure of TN from land use and rural life is about 66.5 and 17.1 %, the TP is about 53.8 and 32.7 %; the maximum source composition of TN (59 %) is farmland; the maximum source

  3. GAS LOSS BY RAM PRESSURE STRIPPING AND INTERNAL FEEDBACK FROM LOW-MASS MILKY WAY SATELLITES

    Energy Technology Data Exchange (ETDEWEB)

    Emerick, Andrew; Low, Mordecai-Mark Mac [Department of Astronomy, Columbia University, New York, NY (United States); Grcevich, Jana [Department of Astrophysics, American Museum of Natural History, New York, NY (United States); Gatto, Andrea [Max-Planck-Institute für Astrophysik, Garching, bei München (Germany)

    2016-08-01

    The evolution of dwarf satellites in the Milky Way (MW) is affected by a combination of ram pressure stripping (RPS), tidal stripping, and internal feedback from massive stars. We investigate gas loss processes in the smallest satellites of the MW using three-dimensional, high-resolution, idealized wind tunnel simulations, accounting for gas loss through both ram pressure stripping and expulsion by supernova feedback. Using initial conditions appropriate for a dwarf galaxy like Leo T, we investigate whether or not environmental gas stripping and internal feedback can quench these low-mass galaxies on the expected timescales, shorter than 2 Gyr. We find that supernova feedback contributes negligibly to the stripping rate for these low star formation rate galaxies. However, we also find that RPS is less efficient than expected in the stripping scenarios we consider. Our work suggests that although RPS can eventually completely strip these galaxies, other physics is likely at play to reconcile our computed stripping times with the rapid quenching timescales deduced from observations of low-mass MW dwarf galaxies. We discuss the roles additional physics may play in this scenario, including host-satellite tidal interactions, cored versus cuspy dark matter profiles, reionization, and satellite preprocessing. We conclude that a proper accounting of these physics together is necessary to understand the quenching of low-mass MW satellites.

  4. THE ROLE OF DIFFERENT RHEOLOGICAL MODELS IN ACCURACY OF PRESSURE LOSS PREDICTION

    Directory of Open Access Journals (Sweden)

    Katarina Simon

    2004-12-01

    Full Text Available Hydraulics play an important function in many oil field operations including drilling, completion, fracturing, acidizing, workover and production. The standard API methods for drilling fluid hydraulics assume either power law or Bingham plastic rheological model. These models and corresponding hydraulic calculations do provide a simple way for fair estimates of hydraulics for conventional vertical wells using simple drilling fluids, such as bentonite fluids. However, nowdays with many wells drilled deep, slim or horizontal using complex muds with unusual behaviour (such as tested MMH mud, it is necessary to use appropriate rheological model for mathematical modelling of fluid behaviour. Oil and gas reservoirs in Croatia have been under production for quite a while and the probability to discover new deposits of hydrocarbons is rather small. Therefore attempts have been made to maintain the gas and oil exploitation at the present level. One of possible ways to meet this target is re-entry wells drilling. The diameter of such wells in reservoir is smaller than 0,1524 m (6 in. Accurate modelling of annular pressure losses becomes therefore an important issue, particularly in cases where a small safety margin exists between optimal drilling parameters and wellbore stability, what is the case in re-entry wells. The objective of the paper is to show the influence of well geometry and accuracy of fluid rheological properties modelling to the distribution of pressure losses in a slimhole well.

  5. Simulation of small break loss of coolant accident in pressurized water reactor (PWR)

    International Nuclear Information System (INIS)

    Abass, N. M. N.

    2012-02-01

    A major safety concern in pressurized-water-reactor (PWR) design is the loss-of-coolant accident (LOCA),in which a break in the primary coolant circuit leads to depressurization, boiling of the coolant, consequent reduced cooling of the reactor core, and , unless remedial measures are taken, overheating of the fuel rods. This concern has led to the development of several simulators for safety analysis. This study demonstrates how the passive and active safety systems in conventional and advanced PWR behave during the small break loss of Coolant Accident (SBLOCA). The consequences of SBOLOCA have been simulated using IAEA Generic pressurized Water Reactor Simulator (GPWRS) and personal Computer Transient analyzer (PCTRAN) . The results were presented and discussed. The study has confirmed the major safety advantage of passive plants versus conventional PWRs is that the passive safety systems provide long-term core cooling and decay heat removal without the need for operator actions and without reliance on active safety-related system. (Author)

  6. Patients with vestibular loss, tullio phenomenon, and pressure-induced nystagmus: vestibular atelectasis?

    Science.gov (United States)

    Wenzel, Angela; Ward, Bryan K; Schubert, Michael C; Kheradmand, Amir; Zee, David S; Mantokoudis, Georgios; Carey, John Patrick

    2014-06-01

    To propose an etiology for a syndrome of bilateral vestibular hypofunction and sound and/or pressure-evoked eye movements with normal hearing thresholds. Retrospective case series. Tertiary care referral center. Four patients with bilateral vestibular hypofunction, sound and/or pressure-evoked nystagmus and normal hearing thresholds were identified over a 3-year period. No evidence of other known vestibular disorders was identified. None of these patients presented with a history of exposure to toxins, radiation, aminoglycosides or chemotherapy; head trauma; or a family history of inherited vestibular loss. All patients underwent high-resolution CT scan of the temporal bones to evaluate for labyrinthine dehiscence. Additionally, all individuals underwent audiometric testing to ANSI standards, vestibular-evoked myogenic potentials (VEMP) testing using either click stimulus cervical VEMPs (cVEMPs), or tone burst ocular VEMPs (oVEMPs). Bithermal caloric stimulation was used to measure horizontal semicircular canal function, with either videonystagmography (VNG) or electronystagmography (ENG) to record eye movements. Individual responses of each of the 6 semicircular canals (SCC) to rapid head rotations were tested with the bedside head impulse test. We identified 4 patients with a combination of bilateral vestibular hypofunction and sound and/or pressure-induced eye movements, normal-hearing thresholds and no evidence for any other vestibular disorder. We suggest that this unique combination of symptoms should be considered as the clinical presentation of vestibular atelectasis, which has been previously described histologically as collapse of the endolymph-containing portions of the labyrinth.

  7. Non-Newtonian fluids: Frictional pressure loss prediction for fully-developed flow in straight pipes

    Science.gov (United States)

    1991-10-01

    ESDU 91025 discusses models used to describe the rheology of time independent pseudohomogeneous non-Newtonian fluids (power-law, Bingham, Herschel-Bulkley and a generalized model due to Metzner and Reed); they are used to calculate the laminar flow pressure drop (which is independent of pipe roughness in this regime). Values of a generalized Reynolds number are suggested to define transitional and turbulent flow. For turbulent flow in smooth pipes, pressure loss is estimated on the basis of an experimentally determined rheogram using either the Dodge-Metzner or Bowen approach depending on the available measurements. Bowen requires results for at least two pipe diameters. The choice of Dodge-Metzner when data are limited is discussed; seven possible methods are assessed against five sets of experimental results drawn from the literature. No method is given for transitional flow, which it is suggested should be avoided, but the turbulent correlation is recommended because it will yield an overestimate. Suggestions are made for the treatment of roughness effects. Several worked examples illustrate the use of the methods and a flowchart guides the user through the process from experimentally characterizing the behavior of the fluid to determining the pressure drop. A computer program, ESDUpac A9125, is also provided.

  8. Evaluation of evaporation coefficient for micro-droplets exposed to low pressure: A semi-analytical approach

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Prodyut R., E-mail: pchakraborty@iitj.ac.in [Department of Mechanical Engineering, Indian Institute of Technology Jodhpur, 342011 (India); Hiremath, Kirankumar R., E-mail: k.r.hiremath@iitj.ac.in [Department of Mathematics, Indian Institute of Technology Jodhpur, 342011 (India); Sharma, Manvendra, E-mail: PG201283003@iitj.ac.in [Defence Laboratory Jodhpur, Defence Research & Development Organisation, 342011 (India)

    2017-02-05

    Evaporation rate of water is strongly influenced by energy barrier due to molecular collision and heat transfer limitations. The evaporation coefficient, defined as the ratio of experimentally measured evaporation rate to that maximum possible theoretical limit, varies over a conflicting three orders of magnitude. In the present work, a semi-analytical transient heat diffusion model of droplet evaporation is developed considering the effect of change in droplet size due to evaporation from its surface, when the droplet is injected into vacuum. Negligible effect of droplet size reduction due to evaporation on cooling rate is found to be true. However, the evaporation coefficient is found to approach theoretical limit of unity, when the droplet radius is less than that of mean free path of vapor molecules on droplet surface contrary to the reported theoretical predictions. Evaporation coefficient was found to reduce rapidly when the droplet under consideration has a radius larger than the mean free path of evaporating molecules, confirming the molecular collision barrier to evaporation rate. The trend of change in evaporation coefficient with increasing droplet size predicted by the proposed model will facilitate obtaining functional relation of evaporation coefficient with droplet size, and can be used for benchmarking the interaction between multiple droplets during evaporation in vacuum.

  9. Evaluation of evaporation coefficient for micro-droplets exposed to low pressure: A semi-analytical approach

    International Nuclear Information System (INIS)

    Chakraborty, Prodyut R.; Hiremath, Kirankumar R.; Sharma, Manvendra

    2017-01-01

    Evaporation rate of water is strongly influenced by energy barrier due to molecular collision and heat transfer limitations. The evaporation coefficient, defined as the ratio of experimentally measured evaporation rate to that maximum possible theoretical limit, varies over a conflicting three orders of magnitude. In the present work, a semi-analytical transient heat diffusion model of droplet evaporation is developed considering the effect of change in droplet size due to evaporation from its surface, when the droplet is injected into vacuum. Negligible effect of droplet size reduction due to evaporation on cooling rate is found to be true. However, the evaporation coefficient is found to approach theoretical limit of unity, when the droplet radius is less than that of mean free path of vapor molecules on droplet surface contrary to the reported theoretical predictions. Evaporation coefficient was found to reduce rapidly when the droplet under consideration has a radius larger than the mean free path of evaporating molecules, confirming the molecular collision barrier to evaporation rate. The trend of change in evaporation coefficient with increasing droplet size predicted by the proposed model will facilitate obtaining functional relation of evaporation coefficient with droplet size, and can be used for benchmarking the interaction between multiple droplets during evaporation in vacuum.

  10. Study on interfacial heat transfer coefficient at metal/die interface during high pressure die casting process of AZ91D alloy

    Directory of Open Access Journals (Sweden)

    GUO Zhi-peng

    2007-02-01

    Full Text Available The high pressure die casting (HPDC process is one of the fastest growing and most efficient methods for the production of complex shape castings of magnesium and aluminum alloys in today’s manufacturing industry.In this study, a high pressure die casting experiment using AZ91D magnesium alloy was conducted, and the temperature profiles inside the die were Measured. By using a computer program based on solving the inverse heat problem, the metal/die interfacial heat transfer coefficient (IHTC was calculated and studied. The results show that the IHTC between the metal and die increases right after the liquid metal is brought into the cavity by the plunger,and decreases as the solidification process of the liquid metal proceeds until the liquid metal is completely solidified,when the IHTC tends to be stable. The interfacial heat transfer coefficient shows different characteristics under different casting wall thicknesses and varies with the change of solidification behavior.

  11. A new method to calculate pressure drop and shell-side heat transfer coefficient in a shell-and-tube heat exchanger

    International Nuclear Information System (INIS)

    Baptista Filho, B.D.; Konuk, A.A.

    1981-01-01

    A new method to calculate pressure drop (Δp) and shell-side heat transfer coefficient (h sub(c)) in a shell-and-tube heat exchanger with segmental baffles is presented. The method is based on the solution of the equations of conservation of mass and momentum between two baffles. The calculated distributions of pressure and velocities given respectively, Δp and h sub(c). The values of Δp and h sub(c) are correlated for a given geometry whit the shell side fluid properties and flow rate. The calculated and experimental results agree very well for a U-Tube heat exchanger. (Author) [pt

  12. Linear and nonlinear optical absorption coefficients in GaAs/Ga1−xAlxAs concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    International Nuclear Information System (INIS)

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A.; Restrepo, R.L.; Duque, C.A.

    2013-01-01

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga 1−x Al x As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: ► Linear and nonlinear intra-band absorption in quantum rings. ► Threshold energy strongly depends on the hydrostatic pressure. ► Threshold energy strongly depends on the stoichiometry and sizes of structure. ► Optical absorption is affected by the incident optical intensity.

  13. Selective loss of orientation column maps in visual cortex during brief elevation of intraocular pressure.

    Science.gov (United States)

    Chen, Xin; Sun, Chao; Huang, Luoxiu; Shou, Tiande

    2003-01-01

    To compare the orientation column maps elicited by different spatial frequency gratings in cortical area 17 of cats before and during brief elevation of intraocular pressure (IOP). IOP was elevated by injecting saline into the anterior chamber of a cat's eye through a syringe needle. The IOP was elevated enough to cause a retinal perfusion pressure (arterial pressure minus IOP) of approximately 30 mm Hg during a brief elevation of IOP. The visual stimulus gratings were varied in spatial frequency, whereas other parameters were kept constant. The orientation column maps of the cortical area 17 were monocularly elicited by drifting gratings of different spatial frequencies and revealed by a brain intrinsic signal optical imaging system. These maps were compared before and during short-term elevation of IOP. The response amplitude of the orientation maps in area 17 decreased during a brief elevation of IOP. This decrease was dependent on the retinal perfusion pressure but not on the absolute IOP. The location of the most visible maps was spatial-frequency dependent. The blurring or loss of the pattern of the orientation maps was most severe when high-spatial-frequency gratings were used and appeared most significantly on the posterior part of the exposed cortex while IOP was elevated. However, the basic patterns of the maps remained unchanged. Changes in cortical signal were not due to changes in the optics of the eye with elevation of IOP. A stable normal IOP is essential for maintaining normal visual cortical functions. During a brief and high elevation of IOP, the cortical processing of high-spatial-frequency visual information was diminished because of a selectively functional decline of the retinogeniculocortical X pathway by a mechanism of retinal circulation origin.

  14. Analysis of water hammer in a penstock in the case of valve closure. Part 2: Pressure losses concentrated downstream

    Directory of Open Access Journals (Sweden)

    Hocine HAMMOUM

    2017-06-01

    Full Text Available In our previous study (Part 1; by using the graphic of Bergeron, we have drawn the relationships which allow calculating flows and pressures at the valve and the reservoir, considering that pressure losses are negligible. Now, we assume in this second contribution that these pressure losses are concentrated downstream of the pipe, just at the entry of the valve. The study will focus on water hammer-induced by a slow closing of the valve. A practical example will be presented at the end of this work in order to illustrate the exposed method.

  15. Pressure ulcer incidence and progression in critically ill subjects: influence of low air loss mattress versus a powered air pressure redistribution mattress.

    Science.gov (United States)

    Black, Joyce; Berke, Christine; Urzendowski, Gail

    2012-01-01

    The primary objective of this study was to compare facility-acquired pressure ulcer incidence and progression of pressure ulcers present on admission in critically ill patients, using 2 different support surfaces. We completed a comparison cohort study in a surgical intensive care unit (ICU). The study setting was a 12-bed cardiovascular ICU in a university-based hospital in the Midwestern United States. The sample comprised 52 critically ill patients; 31 were placed on low air loss weight-based pressure redistribution-microclimate management system beds and 21 were placed on integrated powered air pressure redistribution beds. Prior to the start of the study, 5 low airloss beds were placed in open rooms in the cardiovascular surgical ICU. Inclusion criteria were anticipated ICU stay of 3 days, and patients did not receive a speciality bed for pulmonary or wound issues. Initial assessment of the patients included risk assessment and prior events that would increase risk for pressure ulcer development such as extended time in operating room, along with skin assessment for existing pressure ulcers. Subjects in both groups had ongoing skin assessment every 3 to 4 days and a subjective evaluation of heel elevation and turning or repositioning by the researcher. Data were collected until the subjects were dismissed from the ICU. Patients admitted to the unit were assigned to open rooms following the usual protocols. The mean length of stay was 7.0 days, with an 8.1-day length of stay for subjects on "low air loss with microclimate management" beds (LAL-MCM) and 6.6 days on the integrated power pressure air redistribution (IP-AR) beds (P = NS). The incidence of pressure ulcers on the buttocks, sacrum, or coccyx was 0% (0/31) on the low air loss bed and 18% (4/21) on the IP-AR bed (P = .046). Five subjects had 6 pressure ulcers on admission. Two pressure ulcers on 2 patients worsened on the integrated power air redistribution beds, which required specialty bed rental

  16. Pressure loss in two-phase flow through a microchannel rod bundle

    International Nuclear Information System (INIS)

    Smith, A.C.; Hamm, L.L.; Qureshi, Z.; Steeper, T.J.

    1998-01-01

    The purpose of the microchannel rod bundle two-phase flow test described here was to provide data for benchmarking safety analyses for the accelerator production of tritium (APT). The objective was to obtain pressure loss data for a typical accelerator target rod bundle over a wide range of two-phase flow conditions. The test rod bundle assembly was fabricated for single-phase pressure drop tests conducted at Los Alamos National Laboratory (LANL) and subsequently used for the two-phase flow testing described here. The results for a typical case are given. These results fall generally in the slug flow regime for the horizontal flow results of Fukano and Kariyasaki for a 1.0-mm circular channel. Fukano and Kariyasaki found that surface tension effects were dominant in the 1-mm channel and report no churn regime. The results were also compared with the flow regime maps given by Triplett et al. for flow in discrete microchannels. Triplett employed both circular and trapezoidal channels, the latter to approximate the rod bundle interstitial flow channel shape. It was found that the rod bundle flow fell across the slug-to-churn flow regime transition reported by Triplett. This is consistent with the expectation that cross flow among channels would result in turbulent mixing and would suppress the formation of large discrete bubbles

  17. Effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss

    Science.gov (United States)

    Koval, L. R.

    1976-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. Flow is shown to provide a modest increase in TL that is uniform with frequency up to the critical frequency. The increase is about 2 dB at Mach number M = 0.5, and about 3.5 dB at M = 1. Above the critical frequency where TL is damping controlled, the increase can be slightly larger at certain frequencies. Curvature is found to stiffen the panel, thereby increasing the TL at low frequencies, but also to introduce a dip at the 'ring frequency' of a full cylinder having the same radius as the panel. Pressurization appears to produce a slight decrease in TL throughout the frequency range, and also slightly shifts the dips at the critical frequency and at the ring frequency.

  18. Prevalence of pressure equalization tube placement and hearing loss in children with down syndrome.

    Science.gov (United States)

    Bernardi, Gisele F; Pires, Carolina T F; Oliveira, Nanci P; Nisihara, Renato

    2017-07-01

    To determine the prevalence of pressure equalization tube (PET) placement and hearing loss in children with Down syndrome (DS). We evaluated 90 DS children births between 1 and 11 years old and compared to 90 children without DS paired in sex and age. Medical records were analyzed consecutively. Were collected data about proceedings PET placement, age of the patient at each PET, adenoidectomy, tonsillectomy and results for audiometry and tympanometry. Among the 90 patients with DS, 49 (54.4%) were male, median age of 58 months (15-143 months). In this group, 75 PET were placed in 26/90 children (28.9%) mostly between 3 and 5 years old. In 10/26 (38.5%) was necessary PET replaced. When compared to the control group- 6/90 (6.7%)- children with DS presented OR = 13.7 (95% CI 4.0-47.3) times more likely to use PET. Adenoidectomy and tonsillectomy (44.4% and 42.2% respectively) were significantly more frequent in DS group. The prevalence of hearing loss was 32.1% in the right ear and 26.9% in the left ear. Type B timpanometry was found in more than half of the patients with DS. We found a 13-fold higher risk of PET in DS children, especially between the ages of 3-5 years. The high prevalence of hearing loss and PET placement in patients with DS reinforcing the importance of early and regular follow-up for hearing screening in this population, mostly in preschool-aged children. Copyright © 2017. Published by Elsevier B.V.

  19. Investigation on heat transfer enhancement and pressure loss of double swirl chambers cooling

    Directory of Open Access Journals (Sweden)

    Gang Lin

    2013-09-01

    Full Text Available By merging two standard swirl chambers, an alternative cooling configuration named double swirl chambers (DSC has been developed. In the DSC cooling configuration, the main physical phenomena of the swirl flow in swirl chamber and the advantages of swirl flow in heat transfer augmentation are maintained. Additionally, three new physical phenomena can be found in DSC cooling configuration, which result in a further improvement of the heat transfer: (1 impingement effect has been observed, (2 internal heat exchange has been enhanced between fluids in two swirls, and (3 “∞” shape swirl has been generated because of cross effect between two chambers, which improves the mixing of the fluids. Because of all these improvements, the DSC cooling configuration leads to a higher globally-averaged thermal performance parameter (Nu¯¯/Nu∞/(f/f01/3 than standard swirl chamber. In particular, at the inlet region, the augmentation of the heat transfer is nearly 7.5 times larger than the fully developed non-swirl turbulent flow and the circumferentially averaged Nusselt number coefficient is 41% larger than the standard swirl chamber. Within the present work, a further investigation on the DSC cooling configuration has been focused on the influence of geometry parameters e.g. merging ratio of chambers and aspect ratio of inlet duct on the cooling performance. The results show a very large influence of these geometry parameters in heat transfer enhancement and pressure drop ratio. Compared with the basic configuration of DSC cooling, the improved configuration with 20% to 23% merging ratio shows the highest globally-averaged thermal performance parameter. With the same cross section area in tangential inlet ducts, the DSC cooling channel with larger aspect ratio shows larger heat transfer enhancement and at the same time reduced pressure drop ratio, which results in a better globally-averaged thermal performance parameter.

  20. Pressure-modulated differential scanning calorimetry. An approach to the continuous, simultaneous determination of heat capacities and expansion coefficients.

    Science.gov (United States)

    Boehm, K; Rösgen, J; Hinz, H-J

    2006-02-15

    A new method is described that permits the continuous and synchronous determination of heat capacity and expansibility data. We refer to it as pressure-modulated differential scanning calorimetry (PMDSC), as it involves a standard DSC temperature scan and superimposes on it a pressure modulation of preselected format. The power of the method is demonstrated using salt solutions for which the most accurate heat capacity and expansibility data exist in the literature. As the PMDSC measurements could reproduce the parameters with high accuracy and precision, we applied the method also to an aqueous suspension of multilamellar DSPC vesicles for which no expansibility data had been reported previously for the transition region. Excellent agreement was obtained between data from PMDSC and values from independent direct differential scanning densimetry measurements. The basic theoretical background of the method when using sawtooth-like pressure ramps is given under Supporting Information, and a complete statistical thermodynamic derivation of the general equations is presented in the accompanying paper.

  1. Expert judgment study on wind pressure coefficients. Part 2 : Unprocessed data: Expert rationales Wind tunnel data. Final report

    NARCIS (Netherlands)

    De Wit, S.

    1999-01-01

    In the design of low-rise buildings, wind tunnel experiments are scarcely employed to assess the wind-induced pressures, which are required e.g. for the simulation of ventilation flows or for the evaluation of the structural integrity. Instead, techniques are used, which predominandy rely on inter-

  2. Liquid phase PVTx properties of (water + tert-butanol) binary mixtures at temperatures from 278.15 to 323.15 K and pressures from 0.1 to 100 MPa. II. Molar isothermal compressions, molar isobaric expansions, molar thermal pressure coefficients, and internal pressure

    International Nuclear Information System (INIS)

    Egorov, Gennadiy I.; Makarov, Dmitriy M.; Kolker, Arkadiy M.

    2013-01-01

    Highlights: ► Molar isothermal compressions and molar isobaric expansions were evaluated. ► Coefficients of thermal pressure and internal pressure were obtained. ► Concentration dependences of coefficients under study display extremes. ► Temperature and pressure dependences of internal pressure of the mixture were linear. -- Abstract: Molar isothermal compressions, molar isobaric expansions, molar coefficients of thermal pressure, and internal pressure were calculated over the whole concentration range of {water (1) + tert-butanol (2)} mixture at pressures from 0.1 to 100 MPa and temperatures from 278.15 to 323.15 K. It was revealed that the extremes, observed on concentration dependences of molar isothermal compression K T,m and molar isobaric expansion E P,m of the mixture, became more pronounced with pressure growth and temperature lowering. Values of molar thermal pressure coefficients of the mixture sharply rose at compositions with small TBA mole fraction and then decreased practically linearly with the alcohol content increasing. Temperature and pressure dependences of the mixture internal pressure were almost linear, and at low TBA concentrations changed significantly from the dependences of water, tert-butanol and their mixtures at large alcohol content

  3. Friction pressure drop and heat transfer coefficient of two-phase flow in helically coiled tube once-through steam generator for integrated type marine water reactor

    International Nuclear Information System (INIS)

    Nariai, Hideki; Kobayashi, Michiyuki; Matsuoka, Takeshi.

    1982-01-01

    Two-phase friction pressure drop and heat transfer coefficients in a once-through steam generator with helically coiled tubes were investigated with the model test rig of an integrated type marine water reactor. As the dimensions of the heat transfer tubes and the thermal-fluid conditions are almost the same as those of real reactors, the data applicable directly to the real reactor design were obtained. As to the friction pressure drop, modified Kozeki's prediction which is based on the experimental data by Kozeki for coiled tubes, agreed the best with the experimental data. Modified Martinelli-Nelson's prediction which is based on Martinelli-Nelson's multiplier using Ito's equation for single-phase flow in coiled tube, agreed within 30%. The effect of coiled tube on the average heat transfer coefficients at boiling region were small, and the predictions for straight tube could also be applied to coiled tube. Schrock-Grossman's correlation agreed well with the experimental data at the pressures of lower than 3.5 MPa. It was suggested that dryout should be occurred at the quality of greater than 90% within the conditions of this report. (author)

  4. A Numerical Procedure for Flow Distribution and Pressure Drops for U and Z Type Configurations Plate Heat Exchangers with Variable Coefficients

    International Nuclear Information System (INIS)

    López, R; Lecuona, A; Ventas, R; Vereda, C

    2012-01-01

    In Plate Heat Exchangers it is important to determine the flow distribution and pressure drops, because they affect directly the performance of a heat exchanger. This work proposes an incompressible, one-dimensional, steady state, discrete model allowing for variable overall momentum coefficients to determine these magnitudes. The model consists on a modified version of the Bajura and Jones model for dividing and combining flow manifolds. The numerical procedure is based on the finite differences approximation approach proposed by Datta and Majumdar. A linear overall momentum coefficient distribution is used in the dividing manifold, but the model is not limited to linear distributions. Comparisons are made with experimental, numerical and analytical data, yielding good results.

  5. Pressure-temperature response of a full-pressure PWR containment to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Misak, J.

    1976-01-01

    A mathematical model and computer code TRACO III for pressure-temperature transients in the full-pressure containment of PWR during LOCA is described. Main attention is devoted to the analysis of parametric calculations with respect to the estimation of effect of various factors on the transient process and to the comparison of the theoretical and the experimental results on CVTR. (author)

  6. Effect of a Modest Weight Loss in Normalizing Blood Pressure in Obese Subjects on Antihypertensive Drugs.

    Science.gov (United States)

    Gilardini, Luisa; Redaelli, Gabriella; Croci, Marina; Conti, Antonio; Pasqualinotto, Lucia; Invitti, Cecilia

    2016-01-01

    To assess the effect of a lifestyle intervention in lowering/normalizing blood pressure (BP) levels in hypertensive (controlled or not) obese patients. In this prospective observational study, 490 obese hypertensive patients, 389 controlled (BP < 140/90 mm Hg; CH) and 101 uncontrolled (BP ≥ 140/90 mm Hg; UH) attended a 3-month lifestyle intervention. Before and after the intervention we assessed weight, waist circumference, fat mass, BP, metabolic and renal variables, and physical activity. A multivariate regression model was used to determine the predictors of BP changes. 18.9% of CH and 20.0% of UH were on ≥ 3 antihypertensive drugs. Weight change (average -4.9 ± 2.7%) was independent of the antihypertensive drugs employed. Systolic BP (SBP) decreased by 23 mm Hg and diastolic BP (DBP) by 9 mm Hg, in patients with UH most of whom (89%) normalized BP levels (in 49% after a weight loss < 5%). Age, gender, whole and central obesity, concomitance of type 2 diabetes, chronic renal disease, physical activity intensification, and pharmacological therapy did not affect BP lowering. In the regression analysis with SBP change as dependent variable, weight reduction (β = 0.523, p = 0.005) and group (UH vs. CH, β = -19.40, p = 0.0005) remained associated with SBP reduction. When DBP change was entered as dependent variable, baseline uric acid remained associated with DBP reduction (β = 0.824, p < 0.05). Lifestyle interventions are useful for all obese hypertensive patients in most of whom a modest weight loss is sufficient to normalize BP levels avoiding the aggressive use of multiple antihypertensive drugs. © 2016 The Author(s) Published by S. Karger GmbH, Freiburg.

  7. A study on emergency response guideline during the loss of steam generator secondary heat sink in pressurizer water reactor

    International Nuclear Information System (INIS)

    Yoon, D. J.; Lee, J. Y.; Song, D. S.

    1999-01-01

    A loss of secondary heat sink can occur as a result of several different initiating events, which are a loss of main feedwater during power operation, a loss of off-site power, or any other scenario for which main feedwater is isolated or lost. At this point the opening and closing of the PORV or safety valves will result in a loss of RCS inventory similar in nature to a small break loss of coolant accident. If operator action is not taken, the pressurizer PORV or safety valves will continue to cycle open and closed at the valve setpoint pressure removing RCS inventory and a limited amount of core decay heat until eventually enough inventory will be lost to result in core uncovery. We conclude that a requirement to successfully initiate bleed and feed on steam generator dryout, without any significant core uncovery expected to occur, is that the PORV flow to power ratio must exceed 140 (lbm/hr)/Mwt. For all plants whose PORV capacity is less than 140 (lbm/hr)/Mwt, since symptoms of SG dryout cannot be used to initiate bleed and feed, increasing RCS pressure and temperature or pressure greater than 2335 psig cannot be used. The only alternative symptom available is SG narrow range level. Since Kori 1,2,3 and 4' PORV capacity is more than the criteria, the bleed and feed operation can be initiated at steam generator dryout

  8. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    Energy Technology Data Exchange (ETDEWEB)

    Kryk, Holger, E-mail: h.kryk@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Hoffmann, Wolfgang [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan [Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany)

    2014-12-15

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products.

  9. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    International Nuclear Information System (INIS)

    Kryk, Holger; Hoffmann, Wolfgang; Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan

    2014-01-01

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products

  10. Optimizing the District Heating Primary Network from the Perspective of Economic-Specific Pressure Loss

    Directory of Open Access Journals (Sweden)

    Haichao Wang

    2017-07-01

    Full Text Available A district heating (DH system is one of the most important components of infrastructures in cold areas. Proper DH network design should balance the initial investment and the heat distribution cost of the DH network. Currently, this design is often based on a recommended value for specific pressure loss (R = ∆P/L in the main lines. This will result in a feasible network design, but probably not be optimal in most cases. The paper develops a novel optimization model to facilitate the design by considering the initial investment in the pipes and the heat distribution costs. The model will generate all possible network scenarios consisting of different series of diameters for each pipe in the flow direction of the network. Then, the annuity on the initial investment, the heat distribution cost, and the total annual cost will be calculated for each network scenario, taking into account the uncertainties of the material prices and the yearly operating time levels. The model is applied to a sample DH network and the results indicate that the model works quite well, clearly identifying the optimal network design and demonstrating that the heat distribution cost is more important than the initial investment in DH network design.

  11. A Strain-Based Method to Detect Tires’ Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development

    Directory of Open Access Journals (Sweden)

    Jorge Yunta

    2018-02-01

    Full Text Available Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire’s loss of grip and estimations of the lateral friction coefficient.

  12. A Strain-Based Method to Detect Tires' Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development.

    Science.gov (United States)

    Yunta, Jorge; Garcia-Pozuelo, Daniel; Diaz, Vicente; Olatunbosun, Oluremi

    2018-02-06

    Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire's loss of grip and estimations of the lateral friction coefficient.

  13. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-01-01

    To support the development of a Probabilistic Safety Assessment (PSA) model usable in Riskinformed Applications (RIA) for Korea Standard Nuclear power Plants (KSNP), we have performed a thermal hydraulic analysis of Aggressive Secondary Cooldown (ASC) in a 2-inch Small Break Loss Of Coolant Accident (SBLOCA) with a total loss of High Pressure Safety Injection (HPSI). The present study focuses on the estimation of the success criteria of ASC, and the enhanced understanding of the detailed thermal hydraulic behavior and phenomena. The results have shown that the Reactor Coolant System (RCS) pressure can be reduced to the Low Pressure Safety Injection (LPSI) operation conditions without core damage. It was also shown that more relaxed success criteria compared to those in the previous PSA models of KSNP could be used in the new PSA model. However, it was found that the results could be affected by various parameters related with ASC operation, i.e., reference temperature for the calculation of the cooldown rate and its control method

  14. Loss of interface pressure in various compression bandage systems over seven days.

    Science.gov (United States)

    Protz, Kerstin; Heyer, Kristina; Verheyen-Cronau, Ida; Augustin, Matthias

    2014-01-01

    Manufacturers' instructions of multi-component compression bandage systems inform that these products can remain up to 7 days during the therapy of venous leg ulcer. This implies that the pressure needed will be sustained during this time. The present research investigated the persistence of pressure of compression systems over 7 days. All 6 compression systems available in Germany at the time of the trial were tested on 35 volunteering persons without signs of venous leg disease. Bandaging with short-stretch bandages was included for comparison. Pressure was measured by using PicoPress®. Initially, all products showed sufficient resting pressure of 40 mm Hg checked with a pressure monitor, except for one system in which the pressure fell by at least 23.8%, the maximum being 47.5% over a period of 7 days. The currently available compression systems are not fit to keep the required pressure. Optimized products need to be developed.

  15. Vapour pressures of selected organic compounds down to 1 mPa, using mass-loss Knudsen effusion method

    International Nuclear Information System (INIS)

    Fonseca, José M.S.; Gushterov, Nikola; Dohrn, Ralf

    2014-01-01

    Graphical abstract: - Highlights: • A recently described mass-loss Knudsen apparatus was used for measurements of vapour pressures down to around 1 mPa. • Complementary calorimetric studies were performed in a Calvet-type calorimeter. • New vapour pressures are given for benzoic acid and benzanthrone, in ranges in which no consistent data existed. • Vapour pressures for solid n-octadecane are presented, correcting existing values from literature. - Abstract: A recently developed Knudsen effusion apparatus was improved and used for measurements of vapour pressures of selected organic compounds. Calorimetric studies were conducted using a Calvet-type calorimeter, complementing the information obtained for the vapour pressures and facilitating the modelling and analysis of the data. Vapour pressures of benzoic acid, a reference substance, were determined at temperatures between 269 K and 317 K, corresponding to a pressure range from 2 mPa to 1 Pa, extending the range of results available in the literature to lower pressures. Benzanthrone was studied between temperatures 360 K and 410 K (5 mPa–1 Pa) in order to test the apparatus at higher temperatures. Values presented in the literature for the vapour pressure of solid n-octadecane, one of the most promising compounds to be used as “phase change material” for textile applications, were found inconsistent with the triple point of the substance. Sublimation pressures were measured for this compound between T = 286 K and 298 K (2–20 mPa) allowing the correction of the existing values. Finally, vapour pressures of diphenyl carbonate, a compound of high industrial relevance for its use in the production of polycarbonates, were determined from T = 302 K to 332 K (0.02–1 Pa)

  16. A retrospective study to determine the incidence of pressure ulcers in burn patients using a low air loss pressure relieving mattress.

    Science.gov (United States)

    Still, Joseph M; Wilson, Joan; Rinker, Connie; Law, Edward; Craft-Coffman, Beretta

    2003-06-01

    In immobilized patients, unrelieved pressure can create decubitus ulcers over bony prominences. Those burn patients who require prolonged bed rest, are prone to the development of such problems. Various methods of reducing pressure on these areas, including frequent turning and the use of air fluidized and low air loss beds, have been adopted to attempt to prevent the development of this complication. The Pegasus Renaissance alternating pressure mattress is such a device, intended to reduce the incidence of decubitus ulcers. It was introduced at our burn unit and evaluated over a 29-month period. During the study period, 186 (13.4%) of 1390 acutely burned patients, believed to be at high risk for the development of decubiti, were placed on this mattress. Other patients were treated in the standard hospital bed. Care was otherwise the same. No decubitus ulcers developed in any of the patients treated on the Pegasus Renaissance mattress.

  17. The effect of surface roughness on the heat exchange and pressure-drop coefficients; Influence des rugosites de paroi sur les coefficients d'echange thermique et de perte de charge

    Energy Technology Data Exchange (ETDEWEB)

    Malherbe, J M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-02-15

    The effect of various types of roughness on the wall of an axial tube in an annular space of 15-25 mm cooled by an air-flow has been studied in the case of steady turbulence. Roughness of the type 'disrupter of the boundary layer' was set up using triangular threads of 0.2 to 0.4 mm thickness machined in the tube itself, or brass or glass wire wound on a smooth tube. Tests were also carried out using the roughness provided by regularly spaced pyramids 0.4 mm high. The results obtained showed that the heat exchange increased because of the presence of this roughness. A maximum in the heat exchange and pressure-drop coefficients was observed when the pitch equals about eight times the height of the thread. An analytical method has been developed and experiments have been carried out in which the two walls of the annular space were heated in such a way as to transmit unequal heat flows. The region considered is limited to Reynolds's numbers of between 5 X 10{sup 3} and 5 x 10{sup 4} and wall temperatures of under 250 deg C. (author) [French] L'effet de diverses rugosites sur la paroi du tube central d'un espace annulaire de diametre 15-25 mm refroidi par un ecoulement d'air a ete etudie en regime turbulent etabli. Des rugosites du type 'interrupteur de couche limite' etaient realisees au moyen de filets triangulaires, de 0,2 a 0,4 mm de hauteur usines dans l'epaisseur du tube ou de fils de laiton, ou de verre, enroules sur un tube lisse. Les essais ont porte egalement sur des rugosites constituees par des pyramides de 0,4 mm de hauteur et regulierement espacees. Les resultats obtenus ont mis en evidence une augmentation de transfert de chaleur due a la presence des elements rugueux. L'existence d'un maximum pour les coefficients d'echange thermique et de perte de charge a ete constate lorsque le pas atteint huit fois la hauteur des rugosites. Une methode analytique a ete etablie et des experiences ont ete realisees au cours desquelles les deux parois de l

  18. Comparison of distributed vortex receptivity coefficients at excitation of 3D TS-waves in presence and absence of surface waviness and pressure gradient

    Science.gov (United States)

    Borodulin, V. I.; Ivanov, A. V.; Kachanov, Y. S.; Mischenko, D. A.; Fedenkova, A. A.

    2016-10-01

    The paper is devoted to quantitative experimental investigation of effective mechanisms of excitation of 3D TS instability waves due to distributed boundary layer receptivity to free-stream vortices. Experiments carried out in a self-similar boundary layer with Hartree parameter βH = -0.115 and concentrated on studying two receptivity mechanisms connected with distributed scattering of 3D unsteady free-stream vortices both on the natural boundary layer nonuniformity (smooth surface) and on 2D surface nonuniformity (waviness). Obtained quantitative characteristics (distributed receptivity coefficients) are compared directly with those obtained in Blasius boundary layer. It is found that the adverse pressure gradient leads to reduction of efficiency of the vortex-roughness receptivity mechanism.

  19. Novel Method for Measuring the Heat Collection Rate and Heat Loss Coefficient of Water-in-Glass Evacuated Tube Solar Water Heaters Based on Artificial Neural Networks and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Zhijian Liu

    2015-08-01

    Full Text Available The determinations of heat collection rate and heat loss coefficient are crucial for the evaluation of in service water-in-glass evacuated tube solar water heaters. However, the direct determination requires complex detection devices and a series of standard experiments, which also wastes too much time and manpower. To address this problem, we propose machine learning models including artificial neural networks (ANNs and support vector machines (SVM to predict the heat collection rate and heat loss coefficient without a direct determination. Parameters that can be easily obtained by “portable test instruments” were set as independent variables, including tube length, number of tubes, tube center distance, heat water mass in tank, collector area, final temperature and angle between tubes and ground, while the heat collection rate and heat loss coefficient determined by the detection device were set as dependent variables respectively. Nine hundred fifteen samples from in-service water-in-glass evacuated tube solar water heaters were used for training and testing the models. Results show that the multilayer feed-forward neural network (MLFN with 3 nodes is the best model for the prediction of heat collection rate and the general regression neural network (GRNN is the best model for the prediction of heat loss coefficient due to their low root mean square (RMS errors, short training times, and high prediction accuracies (under the tolerances of 30%, 20%, and 10%, respectively.

  20. Thermal hydraulic analysis of aggressive secondary cooldown in small break loss of coolant accident with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, S. J.; Im, H. K.; Yang, J. U.

    2003-01-01

    Recently, Probabilistic Safety Assessment (PSA) has being applied to various fields as a basic technique of Risk-Informed Applications (RIA). To use RIA, the present study focuses on the detailed thermal hydraulic analyses for major accident sequences and success criteria to support a development of PSA model for Korea Standard Nuclear Power plant (KSNP). The primary purpose of the present study is to evaluate the success criteria of Aggressive Secondary Cooldown (ASC) in Small Break Loss Of Coolant Accident (SBLOCA) with total loss of High Pressure Safety Injection (HPSI) and to enhance the understanding of related thermal hydraulic behavior and phenomena. The accident scenario was 2 inch coldleg break LOCA without HPSI, with 1/2 Low Pressure Safety Injection (LPSI), and performing ASC limited by 55.6 .deg. C /hr (100 .deg. F/hr) cooldown rate at 15 minute after reactor trip, which successively reaches the LPSI condition for about 1.5hr after starting ASC operation with the Peak Cladding Temperature (PCT) of the hottest rod below the core damage criteria 1204.4 .deg. C (2200 .deg. F). In the present study, more relaxed success criteria than the previous PSA for KSNP could be generated under an assumption that operator should maintain the adequate ASC operation. However, it is necessary to evaluate uncertainties arisen from the related parameters of the ASC operation

  1. Review of technical issues related to the failure of Rosemount pressure transmitters due to fill oil loss. Final report

    International Nuclear Information System (INIS)

    James, R.W.; Gaertner, J.P.; Burns, E.T.; Horn, A.; Lee, L.K.

    1994-08-01

    Rosemount pressure transmitters are extensively used in both safety and non-safety applications in US nuclear power plants. They are used to measure pressure, flow, and water level. Rosemount pressure transmitter models 1151, 1152, 1153A, 1153, and 1154 use a fill oil to hydraulically transmit process pressure exerted on outer isolating diaphragms to internal diaphragms. The resulting deflection of the internal diaphragms changes the distance between them and a central diaphragm separating the transmitter interior into two volumes. The change in distance is measured as a change in electrical capacitance between the isolating diaphragms and the central diaphragm and can be related to differential pressure. The fill oil also functions as a dielectric. It has been well established that this fill oil can potentially leak over time, decreasing transmitter accuracy and increasing transmitter response time. Ultimately, the transmitter can fail. An extensive effort has been expended by the nuclear power industry collectively to analyze this issue and develop technically sound and reasonable requirements to mitigate the effects of oil loss in Rosemount pressure transmitters. Despite this, technical concerns have still been raised regarding the technical validity of the past analyses of this problem and its scope. In May 1993, the NRC created an internal group to comprehensively review the Rosemount issue and the NRC's action in addressing it to ensure that all available technical information has been considered. Because this issue remains of active technical interest and because the past work on this subject has been done by many different groups and organizations, EPRI has prepared this report to thoroughly document the current technical understanding of this issue, to perform additional analysis, and to identify any appropriate additional technical research activities regarding oil loss in Rosemount pressure transmitters

  2. Analysis of an accident of local zone control system of 'pressure loss in the compartment water supply reservoir'

    International Nuclear Information System (INIS)

    Catana, A.

    2001-01-01

    This work presents the aftermath of a failure in the Zonal Control System caused by an accident of 'pressure loss in the compartment water supply reservoir' leading to an operational function fault of the liquid zonal control system. Causes for pressure drop may be several, as for instance: simultaneous mechanical fault of the three pumps, class IV total loss of power, a crack of reservoir, etc. Should this accident happens the reactor is shut down automatically by the digital control computer, on the 'ZONE CONTROL SYSTEM FAILURE' setback condition. The analyses were done hypothesizing that the covering gas system is functioning at design parameters and that the only possible accident is the one of pressure loss in supply reservoir. By making use of the software system developed at INR Pitesti, we could make the analysis of the phenomena which take place and thus we could obtain the evolution of the main parameters, namely, neutron and thermohydraulic parameters, as well as the actuating mode of the control and safety systems. Thus, by assuming a pressure drop under 8. 27 bar the 'SETBACK' system is triggered with a final value of the neutron power of 2% FP which can be reached with a power variation rate of 0.00086 decade/sec (- 0.1%/sec). In conclusion, the main parameters evolve as follows: 1. the water level in compartments is 'frozen' at a level at which the pressure in the supply reservoir is 7.3 bar; 2. the mechanical rods are gradually inserted, one bank first and a second one if necessary; 3. the shim rods are fully inserted; 4. the systems of SDS1 and SDS2 scram systems remain unactuated; 5. after 10 minutes from the 'SETBACK' triggering, the neutron power is reduced under 4%; 6. the thermohydraulic parameters of the primary circuit are maintained at normal values; 7. the thermohydraulic parameters of the secondary circuit are maintained at normal values

  3. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    International Nuclear Information System (INIS)

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  4. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    Energy Technology Data Exchange (ETDEWEB)

    Ungan, F., E-mail: fungan@cumhuriyet.edu.tr [Department of Physics, Cumhuriyet University, 58140 Sivas (Turkey); Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Restrepo, R.L. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Escuela de Ingeniería de Antioquia AA 7516, Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Facultad de Ciencias, Universidad Autonoma del Estado de Morelos, Ave. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Morales, A.L.; Duque, C.A. [Grupo de Materia Condensade-UdeA, Instituto de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia)

    2014-02-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga{sub 0.7}Al{sub 0.3}As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications.

  5. Analysis of the effects of the pressure wave generated in loss of coolant accidents in reactor vessels

    International Nuclear Information System (INIS)

    Valero Martinez, M.

    1980-01-01

    The increasing demands in the field of ''Nuclear Safety'', obliges to a perfect knowledge of the causes and effects of every possible accident in a nuclear power plant. In this paper will be analysed the effects of the pressure wave appearing in a LOCA (Loss of collant accident). The pressure wave could deform the following structures: core barrel wall, cover and bottom, control rods and safety coolant system. Any change of the geometry of these structures could provoke and incorrect system reaction after the accident has happened. The basis and hypothesis for the theoretical analysis will be exposed. The structures are considered to be rigid. A typical boiling water be analysed and the developed theory will be verified in comparations with experimental results and the results obtained with some others models. Due to the easy application and short calculation time of the created programmes, they are recommended for parametrical calculations in the analysis of the pressurized water reactors and boiling water reactors. (author)

  6. Understanding and Mitigating Tip Leakage and Endwall Losses in High Pressure Ratio Cores

    Science.gov (United States)

    Christophel, Jesse

    2015-01-01

    Reducing endwall and tip secondary flow losses will be a key enabler for the next generation of commercial and military air transport and will be an improvement on the state-of-the-art in turbine loss reduction strategies. The objective of this research is three-fold: 1) To improve understanding of endwall secondary flow and tip clearance losses 2) To develop novel technologies to mitigate these losses and test them in low-speed cascade and rig environments 3) To validate predictive tools To accomplish these objectives, Pratt & Whitney (P&W) has teamed with Pennsylvania State University (PSU) to experimentally test new features designed by P&W. P&W will create new rim-cavity features to reduce secondary flow loss and improve purge flow cooling effectiveness and new blade tip features to manage leakage flows and reduce tip leakage secondary flow loss. P&W is currently developing technologies in these two areas that expect to be assimilated in the N+2/N+3 generation of commercial engines.

  7. Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding.

    Science.gov (United States)

    Haraldsson, Henrik; Kefayati, Sarah; Ahn, Sinyeob; Dyverfeldt, Petter; Lantz, Jonas; Karlsson, Matts; Laub, Gerhard; Ebbers, Tino; Saloner, David

    2018-04-01

    To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps. A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross-sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation-both including and neglecting the Reynolds stress. Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, -0.52% vs -15.34% error; P Reynolds stress (P Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962-1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Reflooding phase after loss of coolant of an advanced pressurized water reactor with high conversion ratio

    International Nuclear Information System (INIS)

    Schumann, S.

    1984-01-01

    The emergency core cooling behaviour of an advanced pressurized water reactor (APWR) during the reflooding phase of the LOCA with double-ended break is analysed and compared to a common pressurized water reactor (PWR). The code FLUT-BS, its models and correlations are explained in detail and have been verified by numerous PWR-reflood experiments with large parameter range. The influence of core-design on ECC-behaviour as well as the influences of initial and boundary values are examined. The results show the essential differences of ECC-behaviour between PWR and APWR. (orig.) [de

  9. Recurrence of Neurological Deficits in an F/A-18D Pilot Following Loss of Cabin Pressure at Altitude.

    Science.gov (United States)

    Robinson, Tom; Evangelista, Jose S; Latham, Emi; Mukherjee, Samir T; Pilmanis, Andrew

    2016-08-01

    Supersonic, high altitude aviation places its pilots and aircrew in complex environments, which may lead to injury that is not easily diagnosed or simply treated. Decompression illness (either venous or arterial) and environmental conditions (e.g., abnormal gases and pressure) are the most likely adverse effects aircrew often face. Though symptomatic aircrew personnel may occasionally require hyperbaric oxygen treatment, it is rare to require more than one treatment before returning to baseline function. This challenging aviation case details the clinical course and discusses the salient physiological factors of an F/A-18D pilot who presented with neurological symptoms following loss of cabin pressure at altitude. Most crucial to this discussion was the requirement for multiple hyperbaric oxygen treatments over several days due to recurrence of symptoms. The likelihood of recurrence during and after future flights cannot be estimated with accuracy. This case illustrates a degree of recurrences for neurological symptoms in aviation (hypobaric exposure to hyperbaric baseline environment) that has not previously been described. Robinson T, Evangelista JS III, Latham E, Mukherjee ST, Pilmanis A. Recurrence of neurological deficits in an F/A-18D pilot following loss of cabin pressure at altitude. Aerosp Med Hum Perform. 2016; 87(8):740-744.

  10. Yield loss prediction models based on early estimation of weed pressure

    DEFF Research Database (Denmark)

    Asif, Ali; Streibig, Jens Carl; Andreasen, Christian

    2013-01-01

    thresholds are more relevant for site-specific weed management, because weeds are unevenly distributed in fields. Precision of prediction of yield loss is influenced by various factors such as locations, yield potential at the site, variation in competitive ability of mix stands of weed species and emergence...

  11. Prediction of supercooled liquid vapor pressures and n-octanol/air partition coefficients for polybrominated diphenyl ethers by means of molecular descriptors from DFT method

    International Nuclear Information System (INIS)

    Wang Zunyao; Zeng Xiaolan; Zhai Zhicai

    2008-01-01

    The molecular geometries of 209 polybrominated diphenyl ethers (PBDEs) were optimized at the B3LYP/6-31G* level with Gaussian 98 program. The calculated structural parameters were taken as theoretical descriptors to establish two novel QSPR models for predicting supercooled liquid vapor pressures (P L ) and octanol/air partition coefficients (K OA ) of PBDEs based on the theoretical linear solvation energy relationship (TLSER) model, respectively. The two models achieved in this work both contain three variables: most negative atomic partial charge in molecule (q - ), dipole moment of the molecules (μ) and mean molecular polarizability (α), of which R 2 values are both as high as 0.997, their root-mean-square errors in modeling (RSMEE) are 0.069 and 0.062 respectively. In addition, the F-value of two models are both evidently larger than critical values F 0.05 and the variation inflation factors (VIF) of variables herein are all less than 5.0, suggesting obvious statistic significance of the P L and K OA predicting models. The results of Leave-One-Out (LOO) cross-validation for training set and validation with external test set both show that the two models obtained exhibited optimum stability and good predictive power. We suggest that the QSPRs derived here can be used to predict accurately P L and K OA for non-tested PBDE congeners from Mono-BDEs to Hepta-BDEs and from Mono-BDEs to Hexa-BDEs, respectively

  12. Thermal plasma properties for Ar–Al, Ar–Fe and Ar–Cu mixtures used in welding plasmas processes: I. Net emission coefficients at atmospheric pressure

    International Nuclear Information System (INIS)

    Cressault, Y; Gleizes, A

    2013-01-01

    This article is devoted to the calculation of the net emission coefficient (NEC) of Ar–Al, Ar–Fe and Ar–Cu mixtures at atmospheric pressure for arc welding processes. The results are given in data tables for temperatures between 3 kK and 30 kK, for five plasma thicknesses (0, 0.5, 1, 2, 5 mm) and ten concentrations of metallic vapours (pure gas, 0.01%, 0.1%, 1%, 5%, 10%, 25%, 50%, 75% and pure metal vapours in mass proportions). The results are in good agreement with most of the works published on the subject for such mixtures. They highlight the influence of three parameters on the radiation of the plasma: the NEC is directly related to temperature and inversely related to plasma radius and is highly sensitive to the presence of metal vapours. Finally, numerical data are supplied in tables in order to develop accurate computational modelling of welding arc and to estimate both qualitatively and quantitatively the influence of each metallic vapour on the size and on the shape of the weld pool. (paper)

  13. Effect of a high-protein diet on maintenance of blood pressure levels achieved after initial weight loss

    DEFF Research Database (Denmark)

    Engberink, M F; Geleijnse, J M; Bakker, S J L

    2015-01-01

    Randomized trials have shown significant blood pressure (BP) reductions after increased protein compared with carbohydrate intake, but the effect on BP maintenance after initial weight loss is unclear. We examined the effect of a high-protein diet on the maintenance of reduced BP after weight loss......(-2), BP was 118/73 mm Hg and 28 subjects (6.5%) used antihypertensive agents. Systolic BP during 26 weeks of weight maintenance dietary intervention increased in both treatment groups, but it was 2.2 mm Hg less (95% CI: -4.6 to 0.2 mm Hg, P=0.08) in the high-protein group than in the lower...

  14. Axial distribution of deformation in the cladding of pressurized water reactor fuel rods in a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Rose, K.M.; Mann, C.A.; Hindle, E.D.

    1979-01-01

    In the event of a loss-of-coolant accident in a pressurized water reactor, the cladding of the fuel rods would undergo a temperature excursion while being subject to tensile hoop stress. The deformation behavior of 470-mm lengths of Zircaloy-4 fuel cladding has been studied experimentally; under a range of stress levels in the high-alpha range of zirconium (600 to 850 0 C), diametral strains of up to 70% were observed over the greater part of their length. A negative-feedback mechanism is suggested, based on the reduction of secondary creep rate following cooling by enhanced heat loss at swelling areas. An approximate analysis based on this mechanism was found to be in reasonable agreement with the experimental results. A computer modeling code is being developed to predict cladding deformation under realistic conditions

  15. Axial distribution of deformation in the cladding of pressurized water reactor fuel rods in a loss-of-coolant accident

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K.M.; Mann, C.A.; Hindle, E.D.

    1979-12-01

    In the event of a loss-of-coolant accident in a pressurized water reactor, the cladding of the fuel rods would undergo a temperature excursion while being subject to tensile hoop stress. The deformation behavior of 470-mm lengths of Zircaloy-4 fuel cladding has been studied experimentally; under a range of stress levels in the high-alpha range of zirconium (600 to 850/sup 0/C), diametral strains of up to 70% were observed over the greater part of their length. A negative-feedback mechanism is suggested, based on the reduction of secondary creep rate following cooling by enhanced heat loss at swelling areas. An approximate analysis based on this mechanism was found to be in reasonable agreement with the experimental results. A computer modeling code is being developed to predict cladding deformation under realistic conditions.

  16. Dependence of the coefficient of environmental thermal losses of radiation-absorbing thermal exchange panels of flat solar collectors for heating heat-transfer fluid from their average operating and ambient temperatures

    International Nuclear Information System (INIS)

    Avezova, N.R.; Avezov, R.R.

    2015-01-01

    The approximation formula is derived for calculating the normalized coefficient of thermal losses of flat solar collectors (FSCs) for heating heat-transfer fluid (HTF). These are used in hot water supply systems in the warmer part of the year, depending on the average working surface temperature of their radiation-absorbing thermal exchange panels (RATEPs) (t"-_w_s_r) and the ambient temperature (t_a_m_b) in their realistic variation range. (author)

  17. Research on loss of coolant accident of pressurized-water reactor based on PSO algorithm

    International Nuclear Information System (INIS)

    Ma Jie; Guo Lifeng; Peng Qiao

    2012-01-01

    In order to improve the diagnosis performance of Loss of Coolant Accident (LOCA), based on Back Propagation (BP) algorithm study, a fault diagnosis network is established based on Particle Swarm Optimization (PSO) algorithm in this paper. The PSO algorithm is used to train the weights and the thresholds of neural network, which can conquer part convergence problem of BP algorithm. The test results show that the diagnosis network has higher accuracy of LOCA. (authors)

  18. Behaviour of a pressurized-water reactor nuclear power plant during loss-of-coolant accident

    International Nuclear Information System (INIS)

    Adam, E.; Carl, H.; Kubis, K.

    1979-01-01

    Starting from the foundation of the design basis accident in a PWR-type nuclear power plant - Loss of Coolant Accident -the actual status of the processes to be expected in the reactor are described. Operating behaviour of the heat removal system and efficiency of the safety systems are evaluated. Final considerations are concerned with the overall behaviour of the plant under such conditions. Probable failures, shut down times and possibilities of repair are estimated. (author)

  19. Analysis of water hammer in a penstock in the case of valve closure. Part 1: Without pressure losses

    Directory of Open Access Journals (Sweden)

    Hocine HAMMOUM

    2016-04-01

    Full Text Available We develop, in this paper, a method of calculating the water hammer inspired by the graphic construction of Bergeron, which we qualify as analytical method. In helping us of these graphs, we get the relationships that allow calculating the flow rates and pressures along a penstock. The flow of water is carried out by gravity adduction connecting at upstream a storage tank and at downstream a valve. In this first part, we neglect the pressure losses. The study will focus on water hammer-induced by a slow closing of the valve. A practical example will be presented at the end of this work in order to illustrate the exposed method.

  20. CONTEMPT: computer program for predicting containment pressure-temperature response to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Hsii, Y.H.

    1978-04-01

    The CONTEMPT code is used by Babcock and Wilcox for containment analysis following a postulated loss of coolant accident. An additional model is described which is used for the calculation of long term post reflood mass and energy releases to the containment that is used for the containment design basis LOCA calculations. These calculations maximize the rate of energy flow to the containment. The mass and energy data are given to the containment designer for use in calculating the containment building design pressure and temperature and in sizing containment heat removal equipment

  1. Nonlinear dynamic response analysis in piping system for a loss of coolant accident in primary loop of pressurized water reactor

    International Nuclear Information System (INIS)

    Zhang Xiwen; He Feng; Hao Pengfei; Wang Xuefang

    2000-01-01

    Based on the elaborate force and moment analysis with characteristics method and control-volume integrating method for the piping system of primary loop under pressurized water reactor' loss of coolant accident (LOCA) conditions, the nonlinear dynamic response of this system is calculated by the updated Lagrangian formulation (ADINA code). The piping system and virtual underpinning are specially processed, the move displacement of the broken pipe with time is accurately acquired, which is very important and useful for the design of piping system and virtual underpinning

  2. Interfacing systems LOCA (loss-of-coolant accidents): Pressurized water reactors

    International Nuclear Information System (INIS)

    Bozoki, G.; Kohut, P.; Fitzpatrick, R.

    1989-02-01

    This report summarizes a study performed by Brookhaven National Laboratory for the Office of Nuclear Regulatory Research, Reactor and Plant Safety Issues Branch, Division of Reactor and Plant Systems, US Nuclear Regulatory Commission. This study was requested by the NRC in order to provide a technical basis for the resolution of Generic Issue 105 ''Interfacing LOCA at LWRs.'' This report deals with pressurized water reactors (PWRs). A parallel report was also accomplished for boiling water reactors. This study focuses on three representative PWRs and extrapolates the plant-specific findings for their generic applicability. In addition, a generic analysis was performed to investigate the cost-benefit aspects of imposing a testing program that would require some minimum level of leak testing of the pressure isolation valves on plants that presently have no such requirements. 28 refs., 31 figs., 64 tabs

  3. Pressure management strategies for water loss reduction in large-scale water piping networks: a review

    CSIR Research Space (South Africa)

    Adedeji, K

    2017-06-01

    Full Text Available . Therefore, in a WDN with kth number of pipes, the probability of a pipe breakage in the network as a result of the system pressure variations is estimated as [17] 4.35 3.738 5 8 0.0021 21.4 Pr 1 10 k kD D k k k e D e D     (5) where Prk...

  4. Effect of a Modest Weight Loss in Normalizing Blood Pressure in Obese Subjects on Antihypertensive Drugs

    OpenAIRE

    Gilardini, Luisa; Redaelli, Gabriella; Croci, Marina; Conti, Antonio; Pasqualinotto, Lucia; Invitti, Cecilia

    2016-01-01

    Objective To assess the effect of a lifestyle intervention in lowering/normalizing blood pressure (BP) levels in hypertensive (controlled or not) obese patients. Methods In this prospective observational study, 490 obese hypertensive patients, 389 controlled (BP < 140/90 mm Hg; CH) and 101 uncontrolled (BP ≥ 140/90 mm Hg; UH) attended a 3-month lifestyle intervention. Before and after the intervention we assessed weight, waist circumference, fat mass, BP, metabolic and renal variables, and ph...

  5. Low loss hollow optical-waveguide connection from atmospheric pressure to ultra-high vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Ermolov, A.; Mak, K. F.; Tani, F.; Hölzer, P.; Travers, J. C. [Max Planck Institute for the Science of Light, Günther-Scharowsky-Str. 1, 91058 Erlangen (Germany); Russell, P. St. J. [Max Planck Institute for the Science of Light, Günther-Scharowsky-Str. 1, 91058 Erlangen (Germany); Department of Physics, University of Erlangen-Nuremberg, Günther-Scharowsky-Str. 1, 91058 Erlangen (Germany)

    2013-12-23

    A technique for optically accessing ultra-high vacuum environments, via a photonic-crystal fiber with a long small hollow core, is described. The small core and the long bore enable a pressure ratio of over 10{sup 8} to be maintained between two environments, while permitting efficient and unimpeded delivery of light, including ultrashort optical pulses. This delivery can be either passive or can encompass nonlinear optical processes such as optical pulse compression, deep UV generation, supercontinuum generation, or other useful phenomena.

  6. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-03-01

    Recently, Probabilistic Safety Assessment (PSA) has being applied to various fields as a basic technique of Risk-Informed Applications (RIA). The present study focuses on detailed thermal hydraulic analyses for major accident sequences and success criteria to support a development of PSA model using RIA for Korea Standard Nuclear Power plant (KSNP). The primary purpose of the present study in this year is to evaluate the success cri-teria of Aggressive Secondary Cooldown (ASC) in a Small Size Loss Of Coolant Accident (SBLOCA) without HPSI and to enhance the understanding of related thermal hydraulic behavior and phenomena. An effort was made to evaluate the system success criteria and a mission time for the recovery action by an operator to prevent the core damage for that accident scenario. The accident scenario for KSNP was a 2 inch coldleg break LOCA with a total loss of High Pressure Safety Injection (HPSI) and 1/2 Low Pressure Safety Injection (LPSI) available and perform-ing ASC limited by 55.6 .deg. C/hr (100 .deg. F/hr) cooldown rate at 15 minute after reactor trip. It successively reached the LPSI condition for about 1.5hr after starting the ASC operation with the Peak Cladding Temperature (PCT) of the hottest rod below the core damage criteria of 1204.4 .deg. C (2200 .deg. F). Sensitivity studies were performed for (1) cool-ant average temperature parameters, (2) ASC operation control method, (3) operation start time, (4) 1 inch break size. The present analysis identified thermal hydraulic phenomena and parameters affecting on the behavior, which consist of coolant break flow and inventory, parameters governing secondary heat removal, ASC operation control method, and its reference temperature parameters. In the present study, more relaxed success criteria than the previous PSA for KSNP could be generated under an assumption that an operator should maintain the ade-quate ASC operation. However, it is necessary to evaluate the uncertainties arisen from the

  7. Detached-Eddy Simulation of a Fluidic Device for a Prediction of Pressure Loss Characteristics in a Low Flow Mode

    International Nuclear Information System (INIS)

    Lim, Sang Gyu; Lee, Suk Ho; Kim, Han Gon

    2010-01-01

    The Advanced Power Reactor 1400(APR1400) adopts a passive flow controller in Safety Injection Tanks (SITs) as one of Advanced Design Features (ADFs). This device, called a 'Fluidic Device (FD)', controls the flow rate of safety injection water in a passive manner. A flow control mechanism varies the flow resistance in the vortex chamber corresponding to the SIT water level hence the flow rate can be adjusted by the specific flow resistance in a specific flow regime. A full-scale test was performed and the test results met the design requirement of APR1400. To enhance the performance of the FD more effectively, a series of CFD analysis were implemented and remedy of design modification was proposed on the basis of a series of CFD analysis. The results of CFD analysis showed that total discharge time of the fluidic device is to be increased by enhancing the K-factor in consequence of changing the control nozzle angle. However, a tendency of a pressure loss was under-estimated as a limitation of turbulence models such as Reynolds Averaged Navier- Stokes (RANS) models compared to the experimental data. This paper shows that pressure loss characteristics of the FD can be predicted using a Detached-Eddy Simulation (DES) turbulence model, which can provide valuable flow characteristics far exceeding RANS simulations

  8. The effect of blood volume loss on cardiovascular response to lower body negative pressure using a mathematical model

    Science.gov (United States)

    Karam, E. H.; Srinivasan, R. S.; Charles, J. B.; Fortney, S. M.

    1994-01-01

    Different mathematical models of varying complexity have been proposed in recent years to study the cardiovascular (CV) system. However, only a few of them specifically address the response to lower body negative pressure (LBNP), a stress that can be applied in weightlessness to predict changes in orthostatic tolerance. Also, the simulated results produced by these models agree only partially with experimental observations. In contrast, the model proposed by Melchior et al., and modified by Karam et al. is a simple representation of the CV system capable of accurately reproducing observed LBNP responses up to presyncopal levels. There are significant changes in LBNP response due to a loss of blood volume and other alterations that occur in weightlessness and related one-g conditions such as bedrest. A few days of bedrest can cause up to 15% blood volume loss (BVL), with consequent decreases in both stroke volume and cardiac output, and increases in heart rate, mean arterial pressure, and total peripheral resistance. These changes are more pronounced at higher levels of LBNP. This paper presents the results of a simulation study using our CV model to examine the effect of BVL on LBNP response.

  9. Frontier between medium and large break loss of coolant accidents of pressurized water reactor

    Science.gov (United States)

    Kim, Taewan

    2017-10-01

    In order to provide the probabilistic safety assessment with more realistic condition to calculate the frequency of the initiating event, a study on the frontier between medium-break and large-break loss-of-coolant-accidents has been performed by using best-estimate thermal hydraulic code, TRACE. A methodology based on the combination of the essential safety features and system parameter has been applied to the Zion nuclear power plant to evaluate the validity of the frontier utilized for the probabilistic safety assessment. The peak cladding temperature has been chosen as a relevant system parameter that represents the system behavior during the transient. The results showed that the frontier should be extended from 6 in. to 10 in. based on the required safety functions and system response.

  10. COMPARISON OF THE OCTANOL-AIR PARTITION COEFFICIENT AND LIQUID-PHASE VAPOR PRESSURE AS DESCRIPTORS FOR PARTICLE/GAS PARTITIONING USING LABORATORY AND FIELD DATA FOR PCBS AND PCNS

    Science.gov (United States)

    The conventional Junge-Pankow adsorption model uses the sub-cooled liquid vapor pressure (pLo) as a correlation parameter for gas/particle interactions. An alternative is the octanol-air partition coefficient (Koa) absorption model. Log-log plots of the particle-gas partition c...

  11. Effect of a high-protein diet on maintenance of blood pressure levels achieved after initial weight loss : the DiOGenes randomized study

    NARCIS (Netherlands)

    Engberink, M. F.; Geleijnse, J. M.; Bakker, S. J. L.; Larsen, T. M.; Handjieva-Darlesnka, T.; Kafatos, A.; Martinez, J. A.; Pfeiffer, A. F. H.; Kunesova, M.; Jebb, S. A.; Holst, C.; Astrup, A.; Saris, W. H. M.; Brink, E. J.; van Baak, M. A.

    Randomized trials have shown significant blood pressure (BP) reductions after increased protein compared with carbohydrate intake, but the effect on BP maintenance after initial weight loss is unclear. We examined the effect of a high-protein diet on the maintenance of reduced BP after weight loss

  12. Effect of a high-protein diet on maintenance of blood pressure levels achieved after initial weight loss: the DiOGenes randomized study

    NARCIS (Netherlands)

    Engberink, M.F.; Geleijnse, J.M.; Bakker, S.J.L.; Larsen, T.

    2015-01-01

    Randomized trials have shown significant blood pressure (BP) reductions after increased protein compared with carbohydrate intake, but the effect on BP maintenance after initial weight loss is unclear. We examined the effect of a high-protein diet on the maintenance of reduced BP after weight loss

  13. A summary of the assessment of fuel behaviour, fission product release and pressure tube integrity following a postulated large loss-of-coolant accident

    International Nuclear Information System (INIS)

    Langman, V.J.; Weaver, K.R.

    1984-05-01

    The Ontario Hydro analyses of fuel and pressure tube temperatures, fuel behaviour, fission product release and pressure tube integrity for large break loss-of-coolant accidents in Bruce A or Pickering A have been critically reviewed. The determinations of maximum fuel temperatures and fission product release are very uncertain, and pressure tube integrity cannot be assured where low steam flows are predicted to persist for times on the order of minutes

  14. Leak Isolation in Pressurized Pipelines using an Interpolation Function to approximate the Fitting Losses

    Science.gov (United States)

    Badillo-Olvera, A.; Begovich, O.; Peréz-González, A.

    2017-01-01

    The present paper is motivated by the purpose of detection and isolation of a single leak considering the Fault Model Approach (FMA) focused on pipelines with changes in their geometry. These changes generate a different pressure drop that those produced by the friction, this phenomenon is a common scenario in real pipeline systems. The problem arises, since the dynamical model of the fluid in a pipeline only considers straight geometries without fittings. In order to address this situation, several papers work with a virtual model of a pipeline that generates a equivalent straight length, thus, friction produced by the fittings is taking into account. However, when this method is applied, the leak is isolated in a virtual length, which for practical reasons does not represent a complete solution. This research proposes as a solution to the problem of leak isolation in a virtual length, the use of a polynomial interpolation function in order to approximate the conversion of the virtual position to a real-coordinates value. Experimental results in a real prototype are shown, concluding that the proposed methodology has a good performance.

  15. A meta-analysis of the effects of shockwave and high pressure processing on color and cook loss of fresh meat.

    Science.gov (United States)

    Ha, Minh; Dunshea, Frank R; Warner, Robyn D

    2017-10-01

    Meta-analysis is a statistical approach for investigating experimental differences across studies. Meta-analyses were performed to examine the effects of hydrodynamic processing (shockwave; n=12 papers) and high pressure processing (HPP; n=8 papers) on the color and cook loss of fresh meat. Shockwave did not affect color (L*, a*), whereas cook loss was increased by 0.6% relative to untreated meat. HPP resulted in an increase in lightness (L*) and a decrease in redness (a*), with the effect being greater at higher pressures (>300MPa vs pressure (high pressure (>300MPa) the cook loss was increased (-1.5% vs 3.0% respectively). The increased cook loss with shockwave and high pressure (>300MPa) processing needs to be balanced against benefits in texture if this technology is applied to meat. The reduced cook loss of meat treated at moderate pressures (<300MPa) is an advantage which would likely improve sensory traits. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Determination and modelling of osmotic coefficients and vapour pressures of binary systems 1- and 2-propanol with CnMimNTf2 ionic liquids (n = 2, 3, and 4) at T = 323.15 K

    International Nuclear Information System (INIS)

    Calvar, Noelia; Gomez, Elena; Dominguez, Angeles; Macedo, Eugenia A.

    2011-01-01

    Highlights: → Osmotic coefficients of 1- and 2-propanol with C n MimNTf 2 (n = 2, 3, and 4) are determined. → Experimental data were correlated with extended Pitzer model of Archer and MNRTL. → Mean molal activity coefficients and excess Gibbs free energies were calculated. → Effect of the anion is studied comparing these results with literature. - Abstract: The osmotic and activity coefficients and vapour pressures of binary mixtures containing 1-propanol, or 2-propanol and imidazolium-based ionic liquids with bis(trifluoromethylsulfonyl)imide as anion (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, C 2 MimNTf 2 , 1-methyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide, C 3 MimNTf 2 , and 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, C 4 MimNTf 2 ) were determined at T = 323.15 K using the vapour pressure osmometry technique. The experimental osmotic coefficients were correlated using the extended Pitzer model modified by Archer and the MNRTL model, obtaining standard deviations lower than 0.033 and 0.064, respectively. The mean molal activity coefficients and the excess Gibbs free energy for the mixtures studied were calculated from the parameters of the extended Pitzer model modified by Archer. Besides the effect of the alkyl-chain of the cation, the effect of the anion can be assessed comparing the experimental results with those previously obtained for imidazolium ionic liquids with sulphate anions.

  17. Experimental study of heat exchange coefficients, critical heat flux and charge losses, using water-steam mixtures in turbulent flow in a vertical tube; Etude experimentale des coefficients d'echanges thermiques, des flux de chaleur critiques et des pertes de charge avec des melanges eau-vapeur en ecoulement turbulent dans un tube vertical

    Energy Technology Data Exchange (ETDEWEB)

    Perroud, P; De La Harpe, A; Rebiere, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1960-12-15

    Two stainless steel tubes were used (with diameters of 5 and 10 mm, lengths 400 and 600 mm respectively), heated electrically (50 Hz). The mixture flows from top to bottom. The work was carried out mainly on mixtures of high concentration (x > 0.1), at pressures between 50 and 60 kg/cm{sup 2}, flowing as a liquid film on the walls of the tube with droplets suspended in the central current of steam. By analysis of the heat transfer laws the exchange mechanisms were established, and the conditions under which the critical heat flux may be exceeded without danger of actual burnout were determined. In this way high output concentrations (x{sub s} > 0.9) may be obtained. An attempt has been made to find out to what extent existing correlation formulae can be used to account for the phenomena observed. It is shown that those dealing with exchange coefficients can only be applied in a first approximation in cases where exchange by convection is preponderant, and only below the critical flux. The formulae proposed by WAPD and CISE do not give a satisfactory estimation of the critical heat flux, and the essential reasons for this inadequacy are explained. Lastly, the Martinelli and Nelson method may be used to an approximation of 30 per cent for the calculation of charge losses. (author) [French] On a utilise deux tubes en acier inox (avec des diametres de 5 et 10 mm, et des longueurs respectives 400 et 600 mm) chauffes electriquement (50 Hz). Le melange s'ecoule de haut en bas. Les etudes ont porte plus specialement sur des melanges de titres eleves (x > 0,1) a des pressions comprises entre 60 et 90 kg/cm{sup 2} dont l'ecoulement se fait avec film liquide annulaire et gouttelettes en suspension dans le coeur de vapeur. Par l'analyse des lois de transfert de chaleur, on a precise les mecanismes d'echanges et l'on a d'autre part determine dans quelles conditions le flux de chaleur critique peut etre depasse sans danger de 'burnout' proprement dit. On peut ainsi obtenir des

  18. Development of a noise-based method for the determination of the moderator temperature coefficient of reactivity (MTC) in pressurized water reactors (PWRs)

    International Nuclear Information System (INIS)

    Demaziere, C.

    2002-01-01

    The Moderator Temperature Coefficient of reactivity (MTC) is an important safety parameter of Pressurized Water Reactors (PWRs). In most countries, the so-called at-power MTC has to be measured a few months before the reactor outage, in order to determine if the MTC will not become too negative. Usually, the at-power MTC is determined by inducing a change in the moderator temperature, which has to be compensated for by other means, such as a change in the boron concentration. An MTC measurement using the boron dilution method is analysed in this thesis. It is demonstrated that the uncertainty of such a measurement technique is so large, that the measured MTC could become more negative than what the Technical Specifications allow. Furthermore, this technique incurs a disturbance of the plant operation. For this reason, another technique relying on noise analysis was proposed a few years ago. In this technique, the MTC is inferred from the neutron noise measured inside the core and the moderator temperature noise measured at the core-exit, in the same or in a neighbouring fuel assembly. This technique does not require any perturbation of the reactor operation, but was nevertheless proven to underestimate the MTC by a factor of 2 to 5. In this thesis, it is shown, both theoretically and experimentally, that the reason of the MTC underestimation by noise analysis is the radially loosely coupled character of the moderator temperature noise throughout the core. A new MTC noise estimator, accounting for this radially non-homogeneous moderator temperature noise is proposed and demonstrated to give the correct MTC value. This new MTC noise estimator relies on the neutron noise measured in a single point of the reactor and the radially averaged moderator temperature noise measured inside the core. In the case of the Ringhals-2 PWR in Sweden, Gamma-Thermometers (GTs) offer such a possibility since in dynamic mode they measure the moderator temperature noise, whereas in static

  19. The Change of the Seebeck Coefficient Due to Neutron Irradiation and Thermal Fatigue of Nuclear Reactor Pressure Vessel Steel and its Application to the Monitoring of Material Degradation

    International Nuclear Information System (INIS)

    Niffenegger, M.; Reichlin, K.; Kalkhof, D.

    2002-05-01

    The monitoring of material degradation, that might be caused by neutron irradiation and thermal fatigue, is an important topic in lifetime extension of nuclear power plants. We therefore investigated the application of the Seebeck effect for determining material degradation of common reactor pressure vessel steel. The Seebeck coefficient (SC) of several irradiated Charpy specimens made from Japanese JRQ-steel were measured. The specimens suffered a fluence from 0 up to 4.5 x 10 19 neutrons per cm 2 with energies higher than 1 MeV. The measured changes of the SC within this range were about 500 nV, increasing continuously in the range under investigation. Some indications of saturation appeared at fluencies larger than 4.55 x 10 19 neutrons per cm 2 . We obtained a linear dependency between the SC and the temperature shift ΔT 41 of the Charpy-Energy- Temperature curve which is widely used to characterize material embrittlement. Similar measurements were performed on specimens made from the widely used austenitic steel X6CrNiTi18-10 (according to DIN 1.4541) that were fatigued by applying a cyclic strain amplitude of 0.28%. For this kind of fatigue the observed change of SC was somewhat smaller than for the irradiated specimens. Further investigations were made to quantify the size of the gage volume in which the thermoelectric power is generated. It appeared that the information gathered from a Thermo Electric Power (TEP) measurement is very local. To overcome this problem we propose a novel TEP-method using a Thermoelectric Scanning Microscope (TSM). We finally conclude that the change of the SC has a potential for monitoring of material degradation due to neutron irradiation and thermal fatigue, but it has to be taken into account that several influencing parameters could contribute to the TEP in either an additional or extinguishing manner. A disadvantage of the method is the requirement of a clean surface without any oxide layer. A part of this disadvantage can

  20. Experimental investigations of pressure and temperature loads on a containment after a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Kanzleiter, T.F.

    1976-01-01

    For the design of an LWR containment one of the important conditions to be considered is the rapid rise of internal pressure and temperature caused by a loss-of-coolant accident (LOCA) of the primary cooling system. The phenomena occurring within a containment during a LOCA are currently investigated through experiments with a model containment. The experimental results are compared with the results of model calculations to improve the calculational methods. An experimental facility was built, consisting of a primary coolant circuit and a special model containment. The model containment, built in conventional reinforced concrete, has a diameter of 12 m, a height of 12.5 m, a capacity of 580 m 3 and is designed for an internal pressure of 6 bar. The interior is divided by concrete walls and removable partitions into several compartments, which are interconnected through openings with adjustable cross sections. By exchanging the removable partitions it is possible to modify the interior of the containment and to simulate different containment shapes. For the first experiments a PWR configuration with nine compartments has been installed. The model scales of the compartment volumes and the overflow areas are about 1 : 64 compared to the 1200 MW PWR plant Biblis A. (Auth.)

  1. Microfluidic enhancement of intramedullary pressure increases interstitial fluid flow and inhibits bone loss in hindlimb suspended mice.

    Science.gov (United States)

    Kwon, Ronald Y; Meays, Diana R; Tang, W Joyce; Frangos, John A

    2010-08-01

    Interstitial fluid flow (IFF) has been widely hypothesized to mediate skeletal adaptation to mechanical loading. Although a large body of in vitro evidence has demonstrated that fluid flow stimulates osteogenic and antiresorptive responses in bone cells, there is much less in vivo evidence that IFF mediates loading-induced skeletal adaptation. This is due in large part to the challenges associated with decoupling IFF from matrix strain. In this study we describe a novel microfluidic system for generating dynamic intramedullary pressure (ImP) and IFF within the femurs of alert mice. By quantifying fluorescence recovery after photobleaching (FRAP) within individual lacunae, we show that microfluidic generation of dynamic ImP significantly increases IFF within the lacunocanalicular system. In addition, we demonstrate that dynamic pressure loading of the intramedullary compartment for 3 minutes per day significantly eliminates losses in trabecular and cortical bone mineral density in hindlimb suspended mice, enhances trabecular and cortical structural integrity, and increases endosteal bone formation rate. Unlike previously developed modalities for enhancing IFF in vivo, this is the first model that allows direct and dynamic modulation of ImP and skeletal IFF within mice. Given the large number of genetic tools for manipulating the mouse genome, this model is expected to serve as a powerful investigative tool in elucidating the role of IFF in skeletal adaptation to mechanical loading and molecular mechanisms mediating this process.

  2. Contempt-LT: a computer program for predicting containment pressure-temperature response to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Wheat, L.L.; Wagner, R.J.; Niederauer, G.F.; Obenchain, C.F.

    1975-06-01

    CONTEMPT-LT is a digital computer program, written in FORTRAN IV, developed to describe the long-term behavior of water-cooled nuclear reactor containment systems subjected to postulated loss-of-coolant accident (LOCA) conditions. The program calculates the time variation of compartment pressures, temperatures, mass and energy inventories, heat structure temperature distributions, and energy exchange with adjacent compartments. The program is capable of describing the effects of leakage on containment response. Models are provided to describe fan cooler and cooling spray engineered safety systems. Up to four compartments can be modeled with CONTEMPT-LT, and any compartment except the reactor system may have both a liquid pool region and an air-vapor atmosphere region above the pool. Each region is assumed to have a uniform temperature, but the temperatures of the two regions may be different. CONTEMPT-LT can be used to model all current boiling water reactor pressure suppression systems, including containments with either vertical or horizontal vent systems. CONTEMPT-LT can also be used to model pressurized water reactor dry containments, subatmospheric containments, and dual volume containments with an annulus region, and can be used to describe containment responses in experimental containment systems. The program user defines which compartments are used, specifies input mass and energy additions, defines heat structure and leakage systems, and describes the time advancement and output control. CONTEMPT-LT source decks are available in double precision extended-binary-coded-decimal-interchange-code (EBCDIC) versions. Sample problems have been run on the IBM360/75 computer. (U.S.)

  3. Linear and nonlinear optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As concentric double quantum rings: Effects of hydrostatic pressure and aluminum concentration

    Energy Technology Data Exchange (ETDEWEB)

    Baghramyan, H.M. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Barseghyan, M.G., E-mail: mbarsegh@ysu.am [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Kirakosyan, A.A. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Restrepo, R.L. [Escuela de Ingenieria de Antioquia, AA 7516 Medellin (Colombia); Duque, C.A. [Instituto de Fisica, Universidad de Antioquia, AA 1226 Medellin (Colombia)

    2013-02-15

    The linear and nonlinear intra-band optical absorption coefficients in GaAs/Ga{sub 1-x}Al{sub x}As two-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and aluminum concentration the energies of the ground (n=1,l=0) and the first excited state (n=2,l=1) have been found using the effective mass approximation and the transfer matrix formalism. The energies of these states and the corresponding threshold energy of the intra-band optical transitions are examined as a function of hydrostatic pressure and aluminum concentration for different sizes of the structure. We also investigated the dependencies of the linear, nonlinear, and total optical absorption coefficients as functions of the incident photon energy for different values of hydrostatic pressure, aluminum concentration, sizes of the structure, and incident optical intensity. Its is found that the effects of the hydrostatic pressure and the aluminum concentration lead to a shifting of the resonant peaks of the intra-band optical spectrum. - Highlights: Black-Right-Pointing-Pointer Linear and nonlinear intra-band absorption in quantum rings. Black-Right-Pointing-Pointer Threshold energy strongly depends on the hydrostatic pressure. Black-Right-Pointing-Pointer Threshold energy strongly depends on the stoichiometry and sizes of structure. Black-Right-Pointing-Pointer Optical absorption is affected by the incident optical intensity.

  4. Comparison of MHD pressure losses of liquid-lithium flows in coaxial and parallel ducts, passing through strong transverse magnetic fields

    International Nuclear Information System (INIS)

    Trommer, G.

    1979-08-01

    This report deals with theoretical calculations of MHD pressure losses of liquid-lithium flows in tubes of circular cross-section exposed to strong magnetic fields. Some simplifying assumptions were introduced, yielding an analytical solution which allows the pressure drop and losses in double tubes of coaxial geometry to be compared with those in normal flow pipes. The investigations show that coaxial ducts require much more pumping power than normal ones under similar conditions. This great difference of the properties of the two duct types will decrease if the pipes are embedded in materials of good electrical conductivity. In this case the normal duct will afford a drastic increase in the pressure drop, while the coaxial one will be nearly unaffected. But even under these conditions the losses of the latter will dominate. (orig.)

  5. Pressure shift coefficient measurements in an RF discharge for Ar 4s[3/2]2—5p[3/2]3 transition with the help of diodelaser absorption spectroscopy

    Science.gov (United States)

    Chernyshov, A. K.; Mikheyev, P. A.; Lunev, N. N.; Azyazov, V. N.

    2018-04-01

    Optically pumped all-rare-gas laser (OPRGL) with unique properties were recently proposed with a possibility to obtain the laser power on the order of hundreds of Watts from a cubic centimeter. To provide high laser efficiency, the pumping radiation has to match the absorption spectrum of the rare gas metastables. To meet this condition a reliable diagnostics of the key parameters of the active medium is required and knowledge of the broadening and shift coefficients for corresponding transitions of rare gases is necessary. In this paper, the diode-laser absorption spectroscopy was employed to determine the pressure shift coefficient for 811.5 nm Ar line. The value of obtained coefficient in pure argon reduced to 300 K is -(2.1 ± 0.1) × 10-10 s-1cm3. In the course of the study the pressure broadening coefficient was also evaluated and found to be (2.4 ± 0.5) × 10-10 s-1cm3.

  6. Halogenated methyl-phenyl ethers (anisoles) in the environment: determination of vapor pressures, aqueous solubilities, Henry's law constants, and gas/water- (Kgw), n-octanol/water- (Kow) and gas/n-octanol (Kgo) partition coefficients.

    Science.gov (United States)

    Pfeifer, O; Lohmann, U; Ballschmiter, K

    2001-11-01

    Halogenated methyl-phenyl ethers (methoxybenzenes, anisoles) are ubiquitous organics in the environment although they are not produced in industrial quantities. Modelling the fate of organic pollutants such as halogenated anisoles requires a knowledge of the fundamental physico-chemical properties of these compounds. The isomer-specific separation and detection of 60 of the 134 possible congeners allowing an environmental fingerprinting are reported in this study. The vapor pressure p0(L) of more than 60 and further physico-chemical properties of 26 available congeners are given. Vapor pressures p0(L), water solubilities S(L)W, and n-octanol/water partition coefficients Kow were determined by capillary HR-GC (High Resolution Gas Chromatography) on a non-polar phase and by RP-HPLC (Reversed Phase High Performance Liquid Chromatography) on a C18 phase with chlorobenzenes as reference standards. From these experimental data the Henry's law constants H, and the gas/water Kgw and gas/n-octanol Kgo partition coefficients were calculated. We found that vapor pressures, water solubilities, and n-octanol/water partition coefficients of the halogenated anisoles are close to those of the chlorobenzenes. A similar environmental fate of both groups can, therefore, be predicted.

  7. Evaluation of steady flow torques and pressure losses in a rotary flow control valve by means of computational fluid dynamics

    International Nuclear Information System (INIS)

    Okhotnikov, Ivan; Noroozi, Siamak; Sewell, Philip; Godfrey, Philip

    2017-01-01

    Highlights: • A novel design of a rotary flow control valve driven by a stepper motor is proposed. • The intended use of the valve in the high flow rate independent metering hydraulic system is suggested. • Pressure drops, steady flow torques of the valve for various flow rates and orifice openings are studied by means of computational fluid dynamics. • The discharge coefficient and flow jet angles dependencies on the orifice opening are obtained. • A design method to decrease the flow forces without reducing the flow rate in single-staged valves is demonstrated. - Abstract: In this paper, a novel design of a rotary hydraulic flow control valve has been presented for high flow rate fluid power systems. High flow rates in these systems account for substantial flow forces acting on the throttling elements of the valves and cause the application of mechanically sophisticated multi-staged servo valves for flow regulation. The suggested design enables utilisation of single-stage valves in power hydraulics operating at high flow rates regimes. A spool driver and auxiliary mechanisms of the proposed valve design were discussed and selection criteria were suggested. Analytical expressions for metering characteristics as well as steady flow torques have been derived. Computational fluid dynamics (CFD) analysis of steady state flow regimes was conducted to evaluate the hydraulic behaviour of the proposed valve. This study represents a special case of an independent metering concept applied to the design of power hydraulic systems with direct proportional valve control operating at flow rates above 150 litres per minute. The result gained using parametric CFD simulations predicted the induced torque and the pressure drops due to a steady flow. Magnitudes of these values prove that by minimising the number of spool's mobile metering surfaces it is possible to reduce the flow-generated forces in the new generation of hydraulic valves proposed in this study

  8. Radiological consequence analyses of loss of coolant accidents of various break sizes of Pressurized Heavy Water Reactor

    International Nuclear Information System (INIS)

    Sanyasi Rao, V.V.S.; Hari Prasad, M.; Ghosh, A.K.

    2010-01-01

    For any advanced technology, it is essential to ensure that the consequences associated with the accident sequences arising, if any, from the operation of the plant are as low as possible and certainly below the guidelines/limits set by the regulatory bodies. Nuclear power is no exception to this. In this paper consequences of the events arising from Loss of Coolant Accident (LOCA) sequences in Pressurized Heavy Water Reactor (PHWR), are analysed. The sequences correspond to different break sizes of LOCA followed by the operation or otherwise of Emergency Core Cooling System (ECCS). Operation or otherwise of the containment safety systems has also been considered. It has been found that there are no releases to the environment when ECCS is available. The releases, when ECCS is not available, arise from the slack and the ground. The radionuclides considered include noble gases, iodine, and cesium. The hourly meteorological parameters (wind speed, wind direction, precipitation and stability category), considered for this study, correspond to those of Kakrapar site. The consequences evaluated are the thyroid dose and the bone marrow dose received by a person located at various distances from the release point. Isodose curves are generated. From these evaluations, it has been found that the doses are very low. The complementary cumulative frequency distributions (CCFD) for thyroid and bone marrow doses have also been presented for the cases analysed. (author)

  9. Vent clearing during a simulated loss-of-coolant accident in Mark I boiling-water-reactor pressure-suppression system

    International Nuclear Information System (INIS)

    Pitts, J.H.; McCauley, E.W.

    1978-01-01

    The response of the pressure-suspension containment system of Mark I boiling-water reactors to a loss-of-coolant accident (LOCA) is being studied. This response is a design basis for light-water nuclear reactors. Part of the study is being carried out on a 1 / 5 -scale experimental facility that models the pressure-suppression containment system of the Peach Bottom 2 nuclear power plant. The test series reported here focused on the initial or air-clearing phase of a hypothetical LOCA. Measured forces, measured pressures, and the hydrodynamic phenomena (observed with high-speed cameras) show a logical interrelationship

  10. Determination of diffusion coefficients of hydrogen and deuterium in Zr–2.5%Nb pressure tube material using hot vacuum extraction-quadrupole mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shrivastava, Komal Chandra, E-mail: komal@barc.gov.in [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kulkarni, A.S.; Ramanjaneyulu, P.S. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Sunil, Saurav [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Saxena, M.K. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Singh, R.N. [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Tomar, B.S.; Ramakumar, K.L. [Radioanalytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2015-06-15

    The diffusion coefficients of hydrogen and deuterium in Zr–2.5%Nb alloy were measured in the temperature range 523 to 673 K, employing hot vacuum extraction-quadrupole mass spectrometry (HVE-QMS). One end of the Zr–2.5%Nb alloy specimens was charged electrolytically with the desired hydrogen isotope. After annealing at different temperatures for a predetermined time, the specimens were cut into thin slices, which were analyzed for their H{sub 2}/D{sub 2} content using the HVE-QMS technique. The depth profile data were fitted into the equation representing the solution of Fick’s second law of diffusion. The activation energy of hydrogen/deuterium diffusion was obtained from the Arrhenius relation between the diffusion coefficient and temperature. The temperature dependent diffusion coefficient can be represented as D{sub H} = 1.41 × 10{sup −7} exp(−36,000/RT) and D{sub D} = 6.16 × 10{sup −8} exp(−35,262/RT) for hydrogen and deuterium, respectively.

  11. Membrane damage and viability loss of thermally treated and high hydrostatic pressurized E. coli 0157:H7 and Salmonella spp. in apple juice

    Science.gov (United States)

    Differences in membrane damage including leakage of intracellular UV-materials and loss of viability of Salmonella spp. and Escherichia coli O157:H7 bacteria in apple juice following thermal death time disk (TDT) and high hydrostatic pressure treatments were investigated. Salmonella and E. coli O157...

  12. Babcock and Wilcox revisions to CONTEMPT, computer program for predicting containment pressure-temperature response to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Hsii, Y.H.

    1975-01-01

    The CONTEMPT computer program predicts the pressure-temperature response of a single-volume reactor building to a loss-of-coolant accident. The analytical model used for the program is described. CONTEMPT assumes that the loss-of-coolant accident can be separated into two phases; the primary system blowdown and reactor building pressurization. The results of the blowdown analysis serve as the boundary conditions and are input to the CONTEMPT program. Thus, the containment model is only concerned with the pressure and temperature in the reactor building and the temperature distribution through the reactor building structures. The program also calculates building leakage and the effects of engineered safety features such as reactor building sprays, decay heat coolers, sump coolers, etc. 11 references. (U.S.)

  13. Environmental selection pressures related to iron utilization are involved in the loss of the flavodoxin gene from the plant genome.

    Science.gov (United States)

    Pierella Karlusich, Juan J; Ceccoli, Romina D; Graña, Martín; Romero, Héctor; Carrillo, Néstor

    2015-02-16

    Oxidative stress and iron limitation represent the grim side of life in an oxygen-rich atmosphere. The versatile electron transfer shuttle ferredoxin, an iron-sulfur protein, is particularly sensitive to these hardships, and its downregulation under adverse conditions severely compromises survival of phototrophs. Replacement of ferredoxin by a stress-resistant isofunctional carrier, flavin-containing flavodoxin, is a widespread strategy employed by photosynthetic microorganisms to overcome environmental adversities. The flavodoxin gene was lost in the course of plant evolution, but its reintroduction in transgenic plants confers increased tolerance to environmental stress and iron starvation, raising the question as to why a genetic asset with obvious adaptive value was not kept by natural selection. Phylogenetic analyses reveal that the evolutionary history of flavodoxin is intricate, with several horizontal gene transfer events between distant organisms, including Eukarya, Bacteria, and Archaea. The flavodoxin gene is unevenly distributed in most algal lineages, with flavodoxin-containing species being overrepresented in iron-limited regions and scarce or absent in iron-rich environments. Evaluation of cyanobacterial genomic and metagenomic data yielded essentially the same results, indicating that there was little selection pressure to retain flavodoxin in iron-rich coastal/freshwater phototrophs. Our results show a highly dynamic evolution pattern of flavodoxin tightly connected to the bioavailability of iron. Evidence presented here also indicates that the high concentration of iron in coastal and freshwater habitats may have facilitated the loss of flavodoxin in the freshwater ancestor of modern plants during the transition of photosynthetic organisms from the open oceans to the firm land. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  14. 'Are you still on that stupid diet?': women's experiences of societal pressure and support regarding weight loss, and attitudes towards health policy intervention.

    Science.gov (United States)

    Whale, Katie; Gillison, Fiona B; Smith, Paula C

    2014-12-01

    This study investigated how people's attitudes and motivations towards losing weight are influenced by societal pressures surrounding weight loss, their interaction with the obesogenic environment and individuals' attitudes and motivations towards weight. Semi-structured qualitative interviews were conducted with 10 women currently attending commercial weight-loss programmes. Participants experienced conflicting messages regarding weight norms, with the media portraying powerful social norms relating to thinness and beauty, and changes to the food environment and interactions with family and friends commonly undermining weight-loss activities and promoting increased consumption. Providing social and environmental support for the behaviours needed to produce weight loss may need to be a primary focus for obesity policy. © The Author(s) 2013.

  15. Maximum Expected Wall Heat Flux and Maximum Pressure After Sudden Loss of Vacuum Insulation on the Stratospheric Observatory for Infrared Astronomy (SOFIA) Liquid Helium (LHe) Dewars

    Science.gov (United States)

    Ungar, Eugene K.

    2014-01-01

    The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared observation experiments. The experiments carry sensors cooled to liquid helium (LHe) temperatures. A question arose regarding the heat input and peak pressure that would result from a sudden loss of the dewar vacuum insulation. Owing to concerns about the adequacy of dewar pressure relief in the event of a sudden loss of the dewar vacuum insulation, the SOFIA Program engaged the NASA Engineering and Safety Center (NESC). This report summarizes and assesses the experiments that have been performed to measure the heat flux into LHe dewars following a sudden vacuum insulation failure, describes the physical limits of heat input to the dewar, and provides an NESC recommendation for the wall heat flux that should be used to assess the sudden loss of vacuum insulation case. This report also assesses the methodology used by the SOFIA Program to predict the maximum pressure that would occur following a loss of vacuum event.

  16. An estimation of core damage frequency of a pressurized water reactor during midloop operation due to loss of residual heat removal

    International Nuclear Information System (INIS)

    Chao, C.C.; Chen, C.T.; Lee, M.

    1995-01-01

    The core damage frequency caused by loss of residual heat removal (RHR) events was assessed during midloop operation of a Westinghouse-designed three-loop pressurized water reactor. The assessment considers two types of outages (refueling and drained maintenance) and uses failure data collected specifically for shutdown condition. Event trees were developed for five categories of loss of RHR events. Human actions to mitigate the loss of RHR events were identified and human error probabilities were quantified using the human cognitive reliability (HCR) and the technique for human error rate prediction (THERP) models. The results showed that the core damage frequency caused by loss of RHR events during midloop operation was 3.4 x 10 -5 per year. The results also showed that the core damage frequency can be reduced significantly by removing a pressurizer safety valve before entering midloop operation. The establishment of reflux cooling, i.e., decay heat removal through the steam generator secondary side, also plays an important role in mitigating the loss of RHR events during midloop operation

  17. Head-down posture in glaucoma suspects induces changes in IOP, systemic pressure and PERG that predict future loss of optic nerve tissue

    Science.gov (United States)

    Porciatti, Vittorio; Feuer, William J.; Monsalve, Pedro; Triolo, Giacinto; Vazquez, Luis; McSoley, John; Ventura, Lori M.

    2017-01-01

    Purpose To obtain pilot data on posture-induced changes of IOP, systemic pressure and pattern electroretinogram (PERG) predictive of future optic nerve tissue loss glaucoma suspects (GS). Methods Mean peripapillary retinal fiber layer thickness (RNFLT) was measured with OCT two times/year in 28 GS aged 58 ± 8.9 years over 5.0 ± 0.73 years. All patients had a baseline PERG, IOP and brachial blood pressure measurements in the seated and – 10 degrees head-down-body-tilt position (HDT). Outcome measures were seated/HDT PERG amplitude and phase, IOP, mean arterial blood pressure (MAP), and estimated ocular perfusion pressure (OPP). An additional group of 11 similarly-aged controls (SAC) aged 56.9 ± 13 years was tested for comparison. Results While all GS had initial RNFLT in the normal range, 9/28 of them developed significant (P blood pressure, together with their changes upon HDT, may have predictive value for future loss of optic nerve tissue in GS. This study supports the rationale for a full-scale clinical trial to identify patients at high-risk of development of glaucoma. PMID:28263259

  18. Criticality coefficient calculation for a small PWR using Monte Carlo Transport Code

    Energy Technology Data Exchange (ETDEWEB)

    Trombetta, Debora M.; Su, Jian, E-mail: dtrombetta@nuclear.ufrj.br, E-mail: sujian@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Chirayath, Sunil S., E-mail: sunilsc@tamu.edu [Department of Nuclear Engineering and Nuclear Security Science and Policy Institute, Texas A and M University, TX (United States)

    2015-07-01

    Computational models of reactors are increasingly used to predict nuclear reactor physics parameters responsible for reactivity changes which could lead to accidents and losses. In this work, preliminary results for criticality coefficient calculation using the Monte Carlo transport code MCNPX were presented for a small PWR. The computational modeling developed consists of the core with fuel elements, radial reflectors, and control rods inside a pressure vessel. Three different geometries were simulated, a single fuel pin, a fuel assembly and the core, with the aim to compare the criticality coefficients among themselves.The criticality coefficients calculated were: Doppler Temperature Coefficient, Coolant Temperature Coefficient, Coolant Void Coefficient, Power Coefficient, and Control Rod Worth. The coefficient values calculated by the MCNP code were compared with literature results, showing good agreement with reference data, which validate the computational model developed and allow it to be used to perform more complex studies. Criticality Coefficient values for the three simulations done had little discrepancy for almost all coefficients investigated, the only exception was the Power Coefficient. Preliminary results presented show that simple modelling as a fuel assembly can describe changes at almost all the criticality coefficients, avoiding the need of a complex core simulation. (author)

  19. Energy coefficients for a propeller series

    DEFF Research Database (Denmark)

    Olsen, Anders Smærup

    2004-01-01

    The efficiency for a propeller is calculated by energy coefficients. These coefficients are related to four types of losses, i.e. the axial, the rotational, the frictional, and the finite blade number loss, and one gain, i.e. the axial gain. The energy coefficients are derived by use...... of the potential theory with the propeller modelled as an actuator disk. The efficiency based on the energy coefficients is calculated for a propeller series. The results show a good agreement between the efficiency based on the energy coefficients and the efficiency obtained by a vortex-lattice method....

  20. Investigation of a hydrogen mitigation system during large break loss-of-coolant accident for a two-loop pressurized water reactor

    Energy Technology Data Exchange (ETDEWEB)

    Dehjourian, Mehdi; Rahgoshay, Mohmmad; Jahanfamia, Gholamreza [Dept. of Nuclear Engineering, Science and Research Branch, Islamic Azad University of Tehran, Tehran (Iran, Islamic Republic of); Sayareh, Reza [Faculty of Electrical and Computer Engineering, Kerman Graduate University of Technology, Kerman (Iran, Islamic Republic of); Shirani, Amir Saied [Faculty of Engineering, Shahid Beheshti University, Tehran (Iran, Islamic Republic of)

    2016-10-15

    Hydrogen release during severe accidents poses a serious threat to containment integrity. Mitigating procedures are necessary to prevent global or local explosions, especially in large steel shell containments. The management of hydrogen safety and prevention of over-pressurization could be implemented through a hydrogen reduction system and spray system. During the course of the hypothetical large break loss-of-coolant accident in a nuclear power plant, hydrogen is generated by a reaction between steam and the fuel-cladding inside the reactor pressure vessel and also core concrete interaction after ejection of melt into the cavity. The MELCOR 1.8.6 was used to assess core degradation and containment behavior during the large break loss-of-coolant accident without the actuation of the safety injection system except for accumulators in Beznau nuclear power plant. Also, hydrogen distribution in containment and performance of hydrogen reduction system were investigated.

  1. Flow distribution and pressure loss in subchannels of a wire-wrapped 37-pin rod bundle for sodium-cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Seok Kyu; Euh, Dong Jin; Choi, Hae Seob; Kim, Hyung Mo; Choi, Sun Rock; Lee, Hyeong Yeon [Thermal-Hydraulic Safety Research Department, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-04-15

    A hexagonally arrayed 37-pin wire-wrapped rod bundle has been chosen to provide the experimental data of the pressure loss and flow rate in subchannels for validating subchannel analysis codes for the sodium-cooled fast reactor core thermal/hydraulic design. The iso-kinetic sampling method has been adopted to measure the flow rate at subchannels, and newly designed sampling probes which preserve the flow area of subchannels have been devised. Experimental tests have been performed at 20-115% of the nominal flow rate and 60 degrees C (equivalent to Re ∼ 37,100) at the inlet of the test rig. The pressure loss data in three measured subchannels were almost identical regardless of the subchannel locations. The flow rate at each type of subchannel was identified and the flow split factors were evaluated from the measured data. The predicted correlations and the computational fluid dynamics results agreed reasonably with the experimental data.

  2. Boost Pressure Control Strategy to Account for Transient Behavior and Pumping Losses in a Two-Stage Turbocharged Air Path Concept

    Directory of Open Access Journals (Sweden)

    Thivaharan Albin

    2016-07-01

    Full Text Available Increasingly complex air path concepts are investigated to achieve a substantial reduction in fuel consumption while improving the vehicle dynamics. One promising technology is the two-stage turbocharging for gasoline engines, where a high pressure and a low pressure turbocharger are placed in series. For exploiting the high potential, a control concept has to be developed that allows for coordinated management of the two turbocharger stages. In this paper, the control strategy is investigated. Therefore, the effect of the actuated values on transient response and pumping losses is analyzed. Based on these findings, an optimization-based control algorithm is developed that allows taking both requirements into account. The developed new controller allows achieving a fast transient response, while at the same time reducing pumping losses in stationary operation.

  3. Cooldown to residual heat removal entry conditions using atmospheric dump valves and auxiliary pressurizer spray following a loss-of-offsite power at Calvert Cliffs, Unit 1

    International Nuclear Information System (INIS)

    Jenks, R.P.

    1984-01-01

    An investigation of cooldown using atmospheric dump valves (ADVs) and auxiliary pressurizer spray (APS) following loss-of-offsite power at Calvert Cliffs-1 showed residual heat removal entry conditions could not be reached with the plant ADVs alone. Use of APS with the plant ADVs enhanced depressurization, but still provided insufficient cooldown. Effective cooldown and depressurization was shown to occur when rated steady state flow through the ADVs was increased by a factor of four. 6 refs., 30 figs., 2 tabs

  4. The effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss. [acoustic propagation through aircraft fuselage

    Science.gov (United States)

    Koval, L. R.

    1975-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. These effects are incorporated into the classical equations for the TL of single panels, and the resulting double integral for field-incidence TL is numerically evaluated for a specific set of parameters.

  5. Axial gas transport and loss of pressure after ballooning rupture of high burn-up fuel rods subjected to LOCA conditions

    International Nuclear Information System (INIS)

    Wiesenack, Wolfgang; Oberlaender, Barbara; Kekkonen, Laura

    2008-01-01

    The OECD Halden Reactor Project has implemented integral in-pile tests on issues related to fuel behaviour under LOCA conditions. In this test series, the interaction of bonded fuel and cladding, the behaviour of fragmented fuel around the ballooning area, and the axial gas communication in high burn-up rods as affected by gap closure and fuel-clad bonding are of major interest for the investigations. In the Halden reactor tests, the decay heat is simulated by a low level of nuclear heating, in contrast to the heating conditions implemented in hot laboratory set-ups, and the thermal expansion of fuel and cladding relative to each other is more similar to the real event. The paper deals with observations regarding the loss of rod pressure following the rupture of the cladding. In the majority of the tests conducted so far, the rod pressure dropped practically instantaneously as a consequence of ballooning rupture, while one test showed a remarkably slow pressure loss. The slow loss of pressure in this test was analysed, showing that the 'hydraulic diameter' of the rod over an un-distended upper part was about 30 - 35 μm which is typical of high burn-up fuel at hot-standby conditions. The 'plug' of fuel restricts the gas flow from the plenum through the fuel column and thus limits the availability of high pressure gas for driving the ballooning. This observation is relevant for the analysis of the behaviour of a full length fuel rod under LOCA conditions since restricted gas flow may influence bundle blockage and the number of failures. (authors)

  6. Isopiestic determination of the osmotic coefficient and vapour pressure of N-R-4-(N,N-dimethylamino)pyridinium tetrafluoroborate (R = C4H9, C5H11, C6H13) in the ethanol solution at T = 298.15 K

    International Nuclear Information System (INIS)

    Sardroodi, Jaber Jahanbin; Atabay, Maryam; Azamat, Jafar

    2012-01-01

    Highlights: ► The osmotic coefficients of the solutions of ionic liquid in ethanol have been measured. ► Measured osmotic coefficients were correlated using Pitzer, e-NRTL and NRF models and polynomial equation. ► Vapour pressures were evaluated from the correlated osmotic coefficients. - Abstract: Osmotic coefficients of the solutions of room temperature ionic liquid N-R-4-(N,N-dimethylamino)pyridinium tetrafluoroborate (R = C 4 H 9 , C 5 H 11 , C 6 H 13 ) in ethanol have been measured at T = 298.15 K by the isopiestic method. The experimental osmotic coefficients have been correlated using the ion interaction model of Pitzer, electrolyte non-random two liquid (e-NRTL) model of Chen, non-random factor (NRF) and a fourth-order polynomial in terms of molality. The vapour pressures of the solutions studied have been evaluated from the osmotic coefficients.

  7. Beam-Loss Induced Pressure Rise of LHC Collimator Materials Irradiated with 158 GeV/u $In^{49+}$ Ions at the CERN SPS

    CERN Document Server

    Mahner, Edgar; Hansen, Jan; Page, Eric; Vincke, Helmut H

    2004-01-01

    During heavy ion operation, large pressure rises, up to a few orders of magnitude, were observed at CERN, GSI, and BNL. The dynamic pressure rises were triggered by lost beam ions that impacted onto the vacuum chamber walls and desorbed about 1044 to 107 molecules per ion. The deterioration of the dynamic vacuum conditions can enhance charge-exchange beam losses and can lead to beam instabilities or even to beam abortion triggered by vacuum interlocks. Consequently, a dedicated measure-ment of heavy-ion induced molecular desorption in the GeV/u energy range is important for LHC ion operation. In 2003, a desorption experiment was installed at the SPS to measure the beam-loss induced pressure rise of potential LHC collimator materials. Samples of bare graphite, sputter coated (Cu, TiZrV) graphite, and 316 LN stainless steel, were irradiated under grazing angle with 158 GeV/u indium ions. After a description of the new experimental set-up, the results of the pressure rise measurements are presented, and the deri...

  8. Laser-based air data system for aircraft control using Raman and elastic backscatter for the measurement of temperature, density, pressure, moisture, and particle backscatter coefficient.

    Science.gov (United States)

    Fraczek, Michael; Behrendt, Andreas; Schmitt, Nikolaus

    2012-01-10

    Flight safety in all weather conditions demands exact and reliable determination of flight-critical air parameters. Air speed, temperature, density, and pressure are essential for aircraft control. Conventional air data systems can be impacted by probe failure caused by mechanical damage from hail, volcanic ash, and icing. While optical air speed measurement methods have been discussed elsewhere, in this paper, a new concept for optically measuring the air temperature, density, pressure, moisture, and particle backscatter is presented, being independent on assumptions on the atmospheric state and eliminating the drawbacks of conventional aircraft probes by providing a different measurement principle. The concept is based on a laser emitting laser pulses into the atmosphere through a window and detecting the signals backscattered from a fixed region just outside the disturbed area of the fuselage flows. With four receiver channels, different spectral portions of the backscattered light are extracted. The measurement principle of air temperature and density is based on extracting two signals out of the rotational Raman (RR) backscatter signal of air molecules. For measuring the water vapor mixing ratio-and thus the density of the moist air-a water vapor Raman channel is included. The fourth channel serves to detect the elastic backscatter signal, which is essential for extending the measurements into clouds. This channel contributes to the detection of aerosols, which is interesting for developing a future volcanic ash warning system for aircraft. Detailed and realistic optimization and performance calculations have been performed based on the parameters of a first prototype of such a measurement system. The impact and correction of systematic error sources, such as solar background at daytime and elastic signal cross talk appearing in optically dense clouds, have been investigated. The results of the simulations show the high potential of the proposed system for

  9. Coefficient of friction of a starved lubricated spur gear pair

    International Nuclear Information System (INIS)

    Liu, Huaiju; Zhu, Caichao; Sun, Zhangdong; Zhang, Yuanyuan; Song, Chaosheng

    2016-01-01

    The frictional power loss issue of gear pairs becomes an important concern in both industry and academia due to the requirement of the energy saving and the improvement of power density of gear drives. A thermal starved elastohydrodynamic lubrication model is developed to study the tribological performance of a spur gear pair under starved lubrication conditions. The contact pressure, the film thickness, the temperature rise, the frictional power loss, as well as the coefficient of friction are evaluated by considering the variation of the curvature radius, the sliding/rolling motion, and the load distribution of gear tooth within the meshing period. Effects of lubrication starvation condition, load and speed on the coefficient of friction are studied.

  10. Loss-of-Flow and Loss-of-Pressure Simulations of the BR2 Research Reactor with HEU and LEU Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Licht, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Bergeron, A. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States); Sikik, E. [Belgian Nuclear Research Center (SCK-CEN), Mol (Belgium); Van den Branden, G. [Belgian Nuclear Research Center (SCK-CEN), Mol (Belgium); Koonen, E. [Belgian Nuclear Research Center (SCK-CEN), Mol (Belgium)

    2016-01-01

    Belgian Reactor 2 (BR2) is a research and test reactor located in Mol, Belgium and is primarily used for radioisotope production and materials testing. The Materials Management and Minimization (M3) Reactor Conversion Program of the National Nuclear Security Administration (NNSA) is supporting the conversion of the BR2 reactor from Highly Enriched Uranium (HEU) fuel to Low Enriched Uranium (LEU) fuel. The reactor core of BR2 is located inside a pressure vessel that contains 79 channels in a hyperboloid configuration. The core configuration is highly variable as each channel can contain a fuel assembly, a control or regulating rod, an experimental device, or a beryllium or aluminum plug. Because of this variability, a representative core configuration, based on current reactor use, has been defined for the fuel conversion analyses. The code RELAP5/Mod 3.3 was used to perform the transient thermal-hydraulic safety analyses of the BR2 reactor to support reactor conversion. The input model has been modernized relative to that historically used at BR2 taking into account the best modeling practices developed by Argonne National Laboratory (ANL) and BR2 engineers.

  11. Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2

    International Nuclear Information System (INIS)

    Dionne, B.; Tzanos, C.P.

    2011-01-01

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

  12. Experimental verification of integrated pressure suppression systems in fusion reactors at in-vessel loss-of-coolant events

    International Nuclear Information System (INIS)

    Takase, K.; Akimoto, H.

    2001-01-01

    An integrated ICE (Ingress-of-Coolant Event) test facility was constructed to demonstrate that the ITER safety design approach and design parameters for the ICE events are adequate. Major objectives of the integrated ICE test facility are: to estimate the performance of an integrated pressure suppression system; to obtain the validation data for safety analysis codes; and to clarify the effects of two-phase pressure drop at a divertor and the direct-contact condensation in a suppression tank. A scaling factor between the test facility and ITER-FEAT is around 1/1600. The integrated ICE test facility simulates the ITER pressure suppression system and mainly consists of a plasma chamber, vacuum vessel, simulated divertor, relief pipe and suppression tank. From the experimental results it was found quantitatively that the ITER pressure suppression system is very effective to reduce the pressurization due to the ICE event. Furthermore, it was confirmed that the analytical results of the TRAC-PF1 code can simulate the experimental results with high accuracy. (author)

  13. Babcock and Wilcox revisions to CONTEMPT, computer program for predicting containment pressure-temperature response to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Hsii, Y.H.

    1976-06-01

    The CONTEMPT computer program predicts the pressure-temperature response of a single-volume reactor building to a loss-of-coolant accident. The report describes the analytical model used for the program. CONTEMPT assumes that the loss-of-coolant accident can be separated into two phases; the primary system blowdown and reactor building pressurization. The results of the blowdown analysis serve as the boundary conditions and are input to the CONTEMPT program. Thus, the containment model is only concerned with the pressure and temperature in the reactor building and the temperature distribution through the reactor building structures. The user is required to input the description of the discharge of coolant, the boiling of residual water by reactor decay heat, the superheating of steam passing through the core, and metal-water reactions. The reactor building is separated into liquid and vapor regions. Each region is in thermal equilibrium itself, but the two may not be in thermal equilibrium; the liquid and gaseous regions may have different temperatures. The reactor building is represented as consisting of several heat-conducting structures whose thermal behavior can be described by the one-dimensional multi-region heat conduction equation. The program also calculates building leakage and the effects of engineered safety features such as reactor building sprays, decay heat coolers, sump coolers, etc

  14. Beam-loss induced pressure rise of Large Hadron Collider collimator materials irradiated with 158 GeV/u $In^{49+}$ ions at the CERN Super Proton Synchrotron

    CERN Document Server

    Mahner, Edgar; Hansen, Jan; Page, Eric; Vincke, H

    2004-01-01

    During heavy ion operation, large pressure rises, up to a few orders of magnitude, were observed at CERN, GSI, and BNL. The dynamic pressure rises were triggered by lost beam ions that impacted onto the vacuum chamber walls and desorbed about 10/sup 4/ to 10/sup 7/ molecules per ion. The deterioration of the dynamic vacuum conditions can enhance charge-exchange beam losses and can lead to beam instabilities or even to beam abortion triggered by vacuum interlocks. Consequently, a dedicated measurement of heavy-ion induced molecular desorption in the GeV/u energy range is important for Large Hadron Collider (LHC) ion operation. In 2003, a desorption experiment was installed at the super proton synchrotron to measure the beam-loss induced pressure rise of potential LHC collimator materials. Samples of bare graphite, sputter coated (Cu, TiZrV) graphite, and 316 LN (low carbon with nitrogen) stainless steel were irradiated under grazing angle with 158 GeV/u indium ions. After a description of the new experimental ...

  15. Water-column mass losses during the emptying of a large-scale pipeline by pressurized air

    NARCIS (Netherlands)

    Laanearu, J.; Hou, Q.; Annus, I.; Tijsseling, A.S.

    2015-01-01

    In many industrial applications the liquid trapped inside long pipelines can cause a number of problems. Intrusion of the pressurized air on top of the water column inside the horizontal pipeline can result in a less or more mixed stratified flow. The dynamics of a moving air–water front during the

  16. Evaluation of final vapor pressures in the loss of flow accident in an irradiation device of a pool reactor core

    International Nuclear Information System (INIS)

    Verri, A.

    1987-01-01

    The reliability feature, are described for a device containing samples, at a temperatures of 300 grade centigrades, in a reactor core for a long time. After an examination of the maximum accident event, the maximum vapour pressure originated by the inlet of reactor cooling water into the experimental device, is evaluated

  17. Analysis of high-pressure safety valves

    NARCIS (Netherlands)

    Beune, A.

    2009-01-01

    In presently used safety valve sizing standards the gas discharge capacity is based on a nozzle flow derived from ideal gas theory. At high pressures or low temperatures real gas effects can no longer be neglected, so the discharge coefficient corrected for flow losses cannot be assumed constant

  18. Intraindividual Increase of Homeostatic Sleep Pressure Across Acute and Chronic Sleep Loss: A High-Density EEG Study.

    Science.gov (United States)

    Maric, Angelina; Lustenberger, Caroline; Werth, Esther; Baumann, Christian R; Poryazova, Rositsa; Huber, Reto

    2017-09-01

    To compare intraindividually the effects of acute sleep deprivation (ASD) and chronic sleep restriction (CSR) on the homeostatic increase in slow wave activity (SWA) and to relate it to impairments in basic cognitive functioning, that is, vigilance. The increase in SWA after ASD (40 hours of wakefulness) and after CSR (seven nights with time in bed restricted to 5 hours per night) relative to baseline sleep was assessed in nine healthy, male participants (age = 18-26 years) by high-density electroencephalography. The SWA increase during the initial part of sleep was compared between the two conditions of sleep loss. The increase in SWA was related to the increase in lapses of vigilance in the psychomotor vigilance task (PVT) during the preceding days. While ASD induced a stronger increase in initial SWA than CSR, the increase was globally correlated across the two conditions in most electrodes. The increase in initial SWA was positively associated with the increase in PVT lapses. The individual homeostatic response in SWA is globally preserved across acute and chronic sleep loss, that is, individuals showing a larger increase after ASD also do so after CSR and vice versa. Furthermore, the increase in SWA is globally correlated to vigilance impairments after sleep loss over both conditions. Thus, the increase in SWA might therefore provide a physiological marker for individual differences in performance impairments after sleep loss. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  19. CONTEMPT-LT/028: a computer program for predicting containment pressure-temperature response to a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Hargroves, D.W.; Metcalfe, L.J.; Wheat, L.L.; Niederauer, G.F.; Obenchain, C.F.

    1979-03-01

    CONTEMPT-LT is a digital computer program, written in FORTRAN IV, developed to describe the long-term behavior of water-cooled nuclear reactor containment systems subjected to postulated loss-of-coolant accident (LOCA) conditions. The program calculates the time variation of compartment pressures, temperatures, mass and energy inventories, heat structure temperature distributions, and energy exchange with adjacent compartments. The program is capable of describing the effects of leakage on containment response. Models are provided to describe fan cooler and cooling spray engineered safety systems. An annular fan model is also provided to model pressure control in the annular region of dual containment systems. Up to four compartments can be modeled with CONTEMPT-LT, and any compartment except the reactor system may have both a liquid pool region and an air--vapor atmosphere region above the pool. Each region is assumed to have a uniform temperature, but the temperatures of the two regions may be different

  20. Analysis of water hammer-structure interaction in piping system for a loss of coolant accident in primary loop of pressurized water reactor

    International Nuclear Information System (INIS)

    Zhang Xiwen; Yang Jinglong; He Feng; Wang Xuefang

    2000-01-01

    The conventional analysis of water hammer and dynamics response of structure in piping system is divided into two parts, and the interaction between them is neglected. The mechanism of fluid-structure interaction under the double-end break pipe in piping system is analyzed. Using the characteristics method, the numerical simulation of water hammer-structure interaction in piping system is completed based on 14 parameters and 14 partial differential equations of fluid-piping cell. The calculated results for a loss of coolant accident (LOCA) in primary loop of pressurized water reactor show that the waveform and values of pressure and force with time in piping system are different from that of non-interaction between water hammer and structure in piping system, and the former is less than the later

  1. CATHARE2 analysis on the loss of residual heat removal system during mid-loop operation : pressurizer and SGI outlet plenum manways open

    International Nuclear Information System (INIS)

    Chung, Young Jong; Chang, Won Pyo.

    1997-06-01

    The present study is to analyze the BETHSY test 6.9c using CATHARE2 v1.3u. BETHSY test 6.9c simulates plant conditions following loss of residual heat removal system under mid-loop operation. The configuration is that the pressurizer and steam generator outlet plenum manways are opened as vent paths in order to protect the system from overpressurization by removing the steam generated in the core. Most of the important physical phenomena are observed in the experiment have been predicted reasonably by the CATHARE2 code. Since the differential pressure between the pressurizer and the surge line is overestimated, the peak pressure in the upper plenum is predicted higher than the experimental value by 11 kPa and occurrence is delayed by 210s. Also earlier core uncovery is predicted, mainly due to overprediction of the manway flows. The analysis results are demonstrated that opening of the pressurizer and the steam generator outlet plenum manways is effective to prevent the core uncovery by only gravity feed injection. Although some disagreements found in detailed phenomena, the prediction of the overall system behavior by the code does not deviate from the experimental results unacceptably. The core bypass flowrate is found to be very sensitive to mass distribution in the core and the system behaviors are strongly affected by phase separation modeling under low pressure and particularly stratified flow condition. the main purpose of the present study is to understand physical phenomena under the accident and to assess the capability of CATHARE2 prediction for enhancement of reliability in actual plant analyses. (author). 11 refs., 3 tabs., 41 figs

  2. Windage Power Loss in Gas Foil Bearings and the Rotor-Stator Clearance of High Speed Generators Operating in High Pressure Environments

    Science.gov (United States)

    Bruckner, Robert J.

    2009-01-01

    Closed Brayton Cycle (CBC) and Closed Supercritical Cycle (CSC) engines are prime candidates to convert heat from a reactor into electric power for robotic space exploration and habitation. These engine concepts incorporate a permanent magnet starter/generator mounted on the engine shaft along with the requisite turbomachinery. Successful completion of the long-duration missions currently anticipated for these engines will require designs that adequately address all losses within the machine. The preliminary thermal management concept for these engine types is to use the cycle working fluid to provide the required cooling. In addition to providing cooling, the working fluid will also serve as the bearing lubricant. Additional requirements, due to the unique application of these microturbines, are zero contamination of the working fluid and entirely maintenance-free operation for many years. Losses in the gas foil bearings and within the rotor-stator gap of the generator become increasingly important as both rotational speed and mean operating pressure are increased. This paper presents the results of an experimental study, which obtained direct torque measurements on gas foil bearings and generator rotor-stator gaps. Test conditions for these measurements included rotational speeds up to 42,000 revolutions per minute, pressures up to 45 atmospheres, and test gases of nitrogen, helium, and carbon dioxide. These conditions provided a maximum test Taylor number of nearly one million. The results show an exponential rise in power loss as mean operating density is increased for both the gas foil bearing and generator windage. These typical "secondary" losses can become larger than the total system output power if conventional design paradigms are followed. A nondimensional analysis is presented to extend the experimental results into the CSC range for the generator windage.

  3. Determination of safety margins for creep loaded primary circuit components in case of loss of pressure accidents of a HTR plant (SR 383)

    International Nuclear Information System (INIS)

    Breitbach, G.; Ahmed, K.; Over, H.; Schubert, F.; Nickel, H.

    1991-10-01

    The wall thickness of tubes in high temperature plants must be limited in such a way that pressure differences can not produce unadmissible deformations. For HTR (PNP-Plant) the postulated loss of secondary pressure is one of the considered accidents. In that case the tubes of the heat exchangers are loaded by the outher pressure of the primary coolant. So the risk of a creep collapse is given. The report is related to experimental and theoretical work for the creep collapse phenomena. HTR relevant tube geometries of the high temperature alloys NiCr22Co12Mo (INCONEL 617) and X10NiCrAlTi 32 20 (INCOLOY 800) were tested at temperatures of 900 and 950deg C and outer pressure loads in the range 40 bars. The experimental results are compared with theoretically computed values and discussed. The problem of safety margin is treated. Further, simplified procedures are developed for the estimation of the collapse time. (orig.) [de

  4. Heat transfer coefficient for boiling carbon dioxide

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard; Jensen, Per Henrik

    1998-01-01

    Heat transfer coefficient and pressure drop for boiling carbon dioxide (R744) flowing in a horizontal pipe has been measured. The calculated heat transfer coeeficient has been compared with the Chart correlation of Shah. The Chart Correlation predits too low heat transfer coefficient but the ratio...... between the measured and the calculated heat transfer coefficient is nearly constant and equal 1.9. With this factor the correlation predicts the measured data within 14% (RMS). The pressure drop is of the same order as the measuring uncertainty and the pressure drop has not been compared with correlation's....

  5. Pressure drop in flashing flow through obstructions

    International Nuclear Information System (INIS)

    Weinle, M.E.; Johnston, B.S.

    1985-01-01

    An experiment was designed to investigate the pressure drop for flashing flow across obstructions of different geometries at various flow rates. Tests were run using two different orifices to determine if the two-phase pressure drop could be characterized by the single phase loss coefficient and the general behavior of the two-phase multiplier. For the geometries studied, it was possible to correlate the multiplier in a geometry-independent fashion

  6. Donor impurity-related linear and nonlinear optical absorption coefficients in GaAs/Ga{sub 1−x}Al{sub x}As concentric double quantum rings: Effects of geometry, hydrostatic pressure, and aluminum concentration

    Energy Technology Data Exchange (ETDEWEB)

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A. [Department of Solid State Physics, Yerevan State University, Al. Manookian 1, 0025 Yerevan (Armenia); Restrepo, R.L. [Física Teórica y Aplicada, Escuela de Ingeniería de Antioquia, AA 7516, Medellín (Colombia); Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia); Mora-Ramos, M.E. [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia); Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Grupo de Materia Condensada-UdeA, Instituto de Física, Facultadde Ciencias Exactas y Naturales, Universidad de Antioquia UdeA, Calle 70 No. 52-21,Medellín (Colombia)

    2014-01-15

    The linear and nonlinear optical absorption associated with the transition between 1s and 2s states corresponding to the electron-donor-impurity complex in GaAs/Ga{sub 1−x}Al{sub x}As three-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and the variation of the aluminum concentration, the energies of the ground and first excited s-like states of a donor impurity in such a system have been calculated using the effective mass approximation and a variational method. The energies of these states and the corresponding threshold energy of the optical transitions are examined as functions of hydrostatic pressure, aluminum concentration, radial impurity position, as well as the geometrical dimensions of the structure. The dependencies of the linear, nonlinear and total optical absorption coefficients as functions of the incident photon energy are investigated for different values of those mentioned parameters. It is found that the influences mentioned above lead to either redshifts or blueshifts of the resonant peaks of the optical absorption spectrum. It is particularly discussed the unusual property exhibited by the third-order nonlinear of becoming positive for photon energies below the resonant transition one. It is shown that this phenomenon is associated with the particular features of the system under study, which determine the values of the electric dipole moment matrix elements. -- Highlights: • Intra-band optical absorption associated to impurity states in double quantum rings. • Combined effects of hydrostatic pressure and aluminum concentration are studied. • The influences mentioned above lead to shifts of resonant peaks. • It is discussed an unusual property exhibited by the third-order nonlinear absorption.

  7. Donor impurity-related linear and nonlinear optical absorption coefficients in GaAs/Ga1−xAlxAs concentric double quantum rings: Effects of geometry, hydrostatic pressure, and aluminum concentration

    International Nuclear Information System (INIS)

    Baghramyan, H.M.; Barseghyan, M.G.; Kirakosyan, A.A.; Restrepo, R.L.; Mora-Ramos, M.E.; Duque, C.A.

    2014-01-01

    The linear and nonlinear optical absorption associated with the transition between 1s and 2s states corresponding to the electron-donor-impurity complex in GaAs/Ga 1−x Al x As three-dimensional concentric double quantum rings are investigated. Taking into account the combined effects of hydrostatic pressure and the variation of the aluminum concentration, the energies of the ground and first excited s-like states of a donor impurity in such a system have been calculated using the effective mass approximation and a variational method. The energies of these states and the corresponding threshold energy of the optical transitions are examined as functions of hydrostatic pressure, aluminum concentration, radial impurity position, as well as the geometrical dimensions of the structure. The dependencies of the linear, nonlinear and total optical absorption coefficients as functions of the incident photon energy are investigated for different values of those mentioned parameters. It is found that the influences mentioned above lead to either redshifts or blueshifts of the resonant peaks of the optical absorption spectrum. It is particularly discussed the unusual property exhibited by the third-order nonlinear of becoming positive for photon energies below the resonant transition one. It is shown that this phenomenon is associated with the particular features of the system under study, which determine the values of the electric dipole moment matrix elements. -- Highlights: • Intra-band optical absorption associated to impurity states in double quantum rings. • Combined effects of hydrostatic pressure and aluminum concentration are studied. • The influences mentioned above lead to shifts of resonant peaks. • It is discussed an unusual property exhibited by the third-order nonlinear absorption

  8. A Mobile Phone-Based Health Coaching Intervention for Weight Loss and Blood Pressure Reduction in a National Payer Population: A Retrospective Study.

    Science.gov (United States)

    Mao, Alice Yuqing; Chen, Connie; Magana, Candy; Caballero Barajas, Karla; Olayiwola, J Nwando

    2017-06-08

    The prevalence of obesity and associated metabolic conditions continue to be challenging and costly to address for health care systems; 71% of American adults were overweight, with 35% of men and 40% of women diagnosed with obesity in 2014. Digital health coaching is an innovative approach to decreasing the barriers of cost and accessibility of receiving health coaching for the prevention and management of chronic disease in overweight or obese individuals. To evaluate the early impact of a mobile phone-based health coaching service on weight loss and blood pressure management in a commercially insured population. This was a retrospective study using existing registry data from a pilot commercial collaboration between Vida Health and a large national insurance provider, which enrolled adult members who were overweight (body mass index >25 kg/m2) and able to engage in a mobile phone-based coaching intervention. Participants received 4 months of intensive health coaching via live video, phone, and text message through the Vida Health app. Participants were also provided with a wireless scale, pedometer, and blood pressure cuff. Of the 1012 enrolled, 763 (75.40%) participants had an initial weight upon enrollment and final weight between 3 and 5 months from enrollment; they served as our intervention group. There were 73 participants out of the 1012 (7.21%) who had weight data 4 months prior to and after Vida coaching, who served as the matched-pair control group. Participants in the intervention group lost an average of 3.23% total body weight (TBW) at 4 months of coaching and 28.6% (218/763) intervention participants achieved a clinically significant weight loss of 5% or more of TBW, with an average of 9.46% weight loss in this cohort. In the matched-pair control group, participants gained on average 1.81% TBW in 4 months without Vida coaching and lost, on average, 2.47% TBW after 4 months of Vida coaching, demonstrating a statistically significant difference of 4

  9. Effects of Front-Loading and Stagger Angle on Endwall Losses of High Lift Low Pressure Turbine Vanes

    Science.gov (United States)

    2012-09-01

    length scale at z/H = 0.20 ………….… 131 Fig. E.1 Traverse arrangement to enable 3D movement inside the wind tunnel …..… 132 Fig. E.2 Diagram of in...2 ] USAF = United States Air Force 2D = two-dimensional 3D = three-dimensional 1 EFFECTS OF FRONT-LOADING AND STAGGER ANGLE ON ENDWALL...within the wakes. I used Druck LPM 5481 pressure transducers, calibrated using a Ruska 7250LP laboratory standard (the reported accuracy is within

  10. Analysis of the loss of coolant accident due to the faiture in the open position of two pressurizer relief valves, for Angra-1 nuclear power plant

    International Nuclear Information System (INIS)

    Freire, C.F.

    1981-06-01

    A study of the modeling techniques adequate for simulating the loss of coolant accident caused by stuck open pressurizer relief valves, using the RELAP4-MOD5 code, is performed and the model developed is applied to the analysis of this kind of accident for the Central Nuclear Almirante Alvaro Alberto Unit (Angra 1). The thermal hydraulic behavior of the reactor cooling system, when subjected to a loss of main feedwater followed by the failure in the open position of two pressurizer relief valves, is determined. The relief valves are assumed to fail in the totally open position, delivering the maximum massflow through the discharge line. The RELAP4-MOD5 code is shown to be adequate for this kind of analysis, and the detailed prediction of the thermal hydraulic behavior of the Reactor Coolant System is thus possible. The eficiency of the emergency core cooling system of Angra 1 is demonstrated, the fuel elements remaining covered by the coolant during all the accident, and the peak clad temperatures are kept within design limites, ensuring the integrity of the core. (Author) [pt

  11. Effect of bariatric surgery-induced weight loss on renal and systemic inflammation and blood pressure: a 12-month prospective study.

    Science.gov (United States)

    Fenske, Wiebke K; Dubb, Sukhpreet; Bueter, Marco; Seyfried, Florian; Patel, Karishma; Tam, Frederick W K; Frankel, Andrew H; le Roux, Carel W

    2013-01-01

    Bariatric surgery improves arterial hypertension and renal function; however, the underlying mechanisms and effect of different surgical procedures are unknown. In the present prospective study, we compared the 12-month follow-up results after Roux-en-Y gastric bypass, laparoscopic adjustable gastric banding, and laparoscopic sleeve gastrectomy on weight loss, hypertension, renal function, and inflammatory status. A total of 34 morbidly obese patients were investigated before, one and 12 months after Roux-en-Y gastric bypass (n = 10), laparoscopic adjustable gastric banding (n = 13), and laparoscopic sleeve gastrectomy (n = 11) for hypertension, kidney function, urinary and serum cytokine levels of macrophage migration inhibitory factor, monocyte chemotactic protein-1, and chemokine ligand-18. At 12 months after surgery, the patients in all 3 treatment arms showed a significant decrease in the mean body mass index, mean arterial pressure, and urinary and serum inflammatory markers (all P .8 mg/L) had a marked improvement in renal function 12 months after surgery (P < .05). Surgically induced weight loss is associated with a marked decrease in renal and systemic inflammation and arterial hypertension and improvement in renal function in patients with pre-existing renal impairment. These effects appear to be independent of surgical procedure. The improvement in renal inflammation could be 1 of the mechanisms contributing to the beneficial effects of bariatric surgery on arterial blood pressure, proteinuria, and renal function. Copyright © 2013 American Society for Metabolic and Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  12. Numerical prediction of pressure loss in tight-lattice rod bundle by use of 3-dimensional two-fluid model simulation code ACE-3D

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki; Takase, Kazuyuki; Suzuki, Takayuki

    2009-01-01

    Two-fluid model can simulate two-phase flow by computational cost less than detailed two-phase flow simulation method such as interface tracking method or particle interaction method. Therefore, two-fluid model is useful for thermal hydraulic analysis in large-scale domain such as a rod bundle. Japan Atomic Energy Agency (JAEA) develops three dimensional two-fluid model analysis code ACE-3D that adopts boundary fitted coordinate system in order to simulate complex shape flow channel. In this paper, boiling two-phase flow analysis in a tight-lattice rod bundle was performed by the ACE-3D. In the results, the void fraction, which distributes in outermost region of rod bundle, is lower than that in center region of rod bundle. The tendency of void fraction distribution agreed with the measurement results by neutron radiography qualitatively. To evaluate effects of two-phase flow model used in the ACE-3D, numerical simulation of boiling two-phase in tight-lattice rod bundle with no lift force model was also performed. In the results, the lift force model has direct effects on void fraction concentration in gap region, and pressure distribution in horizontal plane induced by void fraction distribution cause of bubble movement from the gap region to the subchannel region. The predicted pressure loss in the section that includes no spacer accorded with experimental results with around 10% of differences. The predicted friction pressure loss was underestimated around 20% of measured values, and the effect of the turbulence model is considered as one of the causes of this underestimation. (author)

  13. Duration of works, flight hours, and blood pressure related to noise-induced hearing loss among Indonesian Air Force helicopter pilots

    Directory of Open Access Journals (Sweden)

    Kholidah Hanum

    2006-09-01

    Full Text Available Helicopter pilots exposed to high intensity noise and other risk factors had increased risk to be noise-induced hearing loss (NIHL. Therefore, it is beneficial to study several risk factors related to NIHL. This study was a nested case-control. Data was extracted from available medical records among helicopter pilots who performed routine aerophysiology training indoctrination (ILA during 1980 through March 2004 at Saryanto Institute for Aviation and Aerospace Medicine (Lakespra, Jakarta. Case was those who had audiogram with a notch of 40 dB or more and of 4000 Hertz on one site or bilateral ears. A case was matched by two controls who free from NIHL up to 2004. All risk factors for cases and controls were counted as of reference date of cases diagnosed. There were 187 medical records available for this study. A number of 32 cases and 64 controls were identified. The final model reveals that NIHL was related to total duration of works, flight hours, and blood pressure. Those who had 500 hours or more than less 500 hours had a moderate increased risk for 2.5 to be NIHL [Adjusted odds ratio (ORa= 2.50; 95% confidence intervals (CI = 0.66-9.29; p = 0.180]. Those who had total duration works 11-24 years had a moderate increased to be NIHL for 2.7 times (ORa = 2.71; 95% CI=0.90-8.10; p = 0.075. Furthermore, prehypertension and hypertension stage 1 subjects than normal blood pressure had moderate trend increased risk to be NIHL. In conclusion total flight hours for 500 hours or more, total duration works 11-24 years, or prehypertension and hypertension stage 1 increased risk NIHL. (Med J Indones 2006; 15:185-90 Keywords: noise induced hearing loss, flight hours, working duration, blood pressure

  14. Hypotensive anesthesia: Comparing the effects of different drug combinations on mean arterial pressure, estimated blood loss, and surgery time in orthognathic surgery.

    Science.gov (United States)

    Jeong, James; Portnof, Jason E; Kalayeh, Mona; Hardigan, Patrick

    2016-07-01

    Sevoflurane, an inhalational hypotensive anesthetic agent with a vasodilatory property, has been commonly used as a single agent to induce hypotension and effectively decrease blood loss in orthognathic surgery. However, it is common for patients to receive other hypotensive anesthetic agents in combination with sevoflurane. The purpose of our retrospective cohort study is to investigate whether administering an additional hypotensive agent has greater effect at reducing mean arterial pressure (MAP), estimated blood loss (EBL) and surgery time during orthognathic surgery. 57 subjects, aged 0-89 of both genders, who underwent orthognathic surgery were investigated in this study. Each patient's anesthesia records were reviewed to record the following variables of interest: EBL, duration of surgery, and MAP reduction in %. 41 subjects were placed in Group I and they received sevoflurane alone. 16 subjects were placed in Group II and they received sevoflurane plus a "supportive" agent. These "supportive" agents were esmolol, labetalol, metoprolol, nicardipine, and dexmedetomidine. The significant differences between two groups were assessed by using ANCOVA and p surgery time. Subjects in Group II experienced a greater reduction in MAP during surgery than subjects in Group I, 27.30% and 20.44%, respectively (p = 0.027). There was no significant difference for sex (p = 0.417) or age group (p = 0.113) in estimated blood loss, however. The mean surgery time in Group I was 1.93, 2.77, and 4.54 h with respect to LeFort, BSSO/IVRO, and double jaw surgery. Patients in Group II had a mean surgery time of 1.73, 2.07, and 5.64 h with respect to LeFort, BSSO/IVRO, and double jaw surgery. No statistically significant difference was demonstrated in surgery time between Group I vs. Group II (p > 0.05). Subjects in Group II experienced, on average, more blood loss than subjects in Group I, 355.50 ml and 238.90 ml, respectively. The use of multi-drug combination may offer

  15. Stresses and strains in the steel containment resulting from transient pressure and temperature loading during loss-of-coolant accident

    International Nuclear Information System (INIS)

    Gruner, P.; Kuntze, W.M.; Jansky, J.

    1985-01-01

    Posttest calculations of stresses and strains in the steel containment of the German research reactor HDR were performed for a simulated LOCA. The results of the theoretical investigations are presented and compared to experimental findings. The pressure and temperature loading of the shell was determined with the thermodynamic code COFLOW on the basis of a multi-compartment model. Using a three-dimensional finite element model the temporal behaviour of the containment was calculated employing the structural mechanics code ASKA. Global bending deformations and local negative straining of the steel shell is discussed. Theoretical and experimental results agree in most cases rather well. Reasons for deviations will be discussed. The specific behaviour of strains found in the vicinity of locally heated areas will be explained by means of analytical considerations. (orig.)

  16. Investigations of the reflood-phase after a loss-of-coolant-accident of an advanced pressurized water reactor (APWR)

    International Nuclear Information System (INIS)

    Schumann, S.; Oldekop, W.

    1983-01-01

    Differences between a high converting advanced pressurized-water reactor (APWR) and a conventional PWR, which are relevant to the reflood-phase after LOCA are presented. The used code and its verification by PWR-reflood experiments is explained. Comparative calculations for APWR and PWR with several conservative assumptions for example cold-leg-injection only, yield nearly the same maximum midplane-temperatures for the average-channel. For the APWR, however, the upper half of the rod shows higher temperatures. Quenchfront and core-water-level increase more slowly. The differences in the reflood-thermohydraulics are analysed in detail. A conservative hot-channel calculation shows maximum temperatures of about 920 0 C. Finally the influence of conservative assumptions is described and the necessity of experiments pointed out. (orig.)

  17. Development and validation of a CFD based methodology to estimate the pressure loss of flow through perforated plates

    International Nuclear Information System (INIS)

    Barros Filho, Jose A.; Navarro, Moyses A.; Santos, Andre A.C. dos; Jordao, E.

    2011-01-01

    In spite of the recent great development of Computational Fluid Dynamics (CFD), there are still some issues about how to assess its accurateness. This work presents the validation of a CFD methodology devised to estimate the pressure drop of water flow through perforated plates similar to the ones used in some reactor core components. This was accomplished by comparing the results of CFD simulations against experimental data of 5 perforated plates with different geometric characteristics. The proposed methodology correlates the experimental data within a range of ± 7.5%. The validation procedure recommended by the ASME Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer-V and V 20 is also evaluated. The conclusion is that it is not adequate to this specific use. (author)

  18. Analysis of the behaviour of pressure and temperature of the containment of a PWR reactor, submitted to a postulated loss-of-coolant accident

    International Nuclear Information System (INIS)

    Silva, D.E. da; Arrieta, L.A.J.; Costa, J.R.; Camargo, C.; Santos, C.M. dos; Rochedo, E.R.R.

    1979-12-01

    The main purpose of this work is to analyse the pressure and temperature behaviour of the metalic containment of a PWR building, submitted to a postulated loss-of-coolant accident (LOCA) caused by a double-ended rupture in the main line of the primary circuit. The scope of the study was directed to verify the Final Safety Analysis Report (FSAR) results for the integrity of the metalic containment of the Angra I power plant. The highest containment pressure peak for this unit is expected for a break in the suction line of one of the main pumps of the primary coolant. Using the same input data, our results are very similar to those presented in the FSAR which shows a reasonable equivalence between the two analytical models. Using as input data the results of a previous LOCA study at CNEN, which yields to more conservative boundary conditions than those presented by the FSAR, the pressure and temperature peak values determined by our model are quite larger than those presented by the cited Safety Report. (author) [pt

  19. Simulation of containment pressurization in a large break-loss of coolant accident using single-cell and multicell models and CONTAIN code

    International Nuclear Information System (INIS)

    Kalkahoran, Omid Noori; Ahangari, Rohollah; Shirani, Amir Saied

    2016-01-01

    Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA) by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model). In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP) containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code's results

  20. Simulation of Containment Pressurization in a Large Break-Loss of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code

    Directory of Open Access Journals (Sweden)

    Omid Noori-Kalkhoran

    2016-10-01

    Full Text Available Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model. In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code’s results.

  1. Simulation of containment pressurization in a large break-loss of coolant accident using single-cell and multicell models and CONTAIN code

    Energy Technology Data Exchange (ETDEWEB)

    Kalkahoran, Omid Noori; Ahangari, Rohollah [Reactor Research School, Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Shirani, Amir Saied [Faculty of Engineering, Shahid Beheshti University, Tehran (Iran, Islamic Republic of)

    2016-10-15

    Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA) by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model). In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP) containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code's results.

  2. Experimental investigations of pressure and temperature loads on a containment after a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Kanzleiter, T.

    1975-10-01

    The phenomena occuring within a containment during a LOCA are currently investigated through experiments with a modelcontainment at Battelle-Institut Frankfurt on behalf of the Bundesministerium fuer Forschung und Technologie, Bonn. The experimental results are to be compared with the results of model calculations in order to improve the calculational methods. An experimental facility was built, consisting of a primary coolant circuit and a special model-containment. The model-containment, built in conventional reinforced concrete, has a diameter of 12 m, a height of 12.5 m, a capacity of 580 m 3 and is designed for an internal pressure of 6 bar. The interior is divided by concrete walls and removable partitions into several compartments, which are interconnected through openings with adjustable cross section. By exchanging the removable partitions it is possible to modify the interior of the containment and to simulate different containment shapes. For the first experiment a PWR-configuration with nine compartments has been istalled. The model scale of the compartment volumes and the overflow areas are about 1:64 compared to the 1,200-MW-PWR-plant Biblis A. Later investigations will also include BWR-experiments and experiments leading to an extremely high load on special containment structures. (orig.) [de

  3. LOFT/LP-SB-3, Loss of Fluid Test, Cold Leg Break LOCA, No High Pressure injection System (HPIS)

    International Nuclear Information System (INIS)

    1989-01-01

    1 - Description of test facility: The LOFT Integral Test Facility is a scale model of a LPWR. The intent of the facility is to model the nuclear, thermal-hydraulic phenomena which would take place in a LPWR during a LOCA. The general philosophy in scaling coolant volumes and flow areas in LOFT was to use the ratio of the LOFT core [50 MW(t)] to a typical LPWR core [3000 MW(t)]. For some components, this factor is not applied; however, it is used as extensively as practical. In general, components used in LOFT are similar in design to those of a LPWR. Because of scaling and component design, the LOFT LOCA is expected to closely model a LPWR LOCA. 2 - Description of test: The sixth OECD LOFT experiment was conducted on 5 March 1984. It simulated a 1.8-in cold leg break LOCA with no HPIS available. This experiment was designed mainly for investigation of plant recovery effectiveness using secondary bleed and feed during core uncover and addressed accumulator injection at low pressure differentials. 3 - Experimental limitations or shortcomings: Short core and steam generator, excessive core bypass, other scaling compromises, and lack of adequate measurements in certain areas

  4. An Experimental Investigation of the Flow Physics Associated With End Wall Losses and Large Rotor Tip Clearances as Found in the Rear Stages of a High Pressure Compressor

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2015-01-01

    measurements have also been used to calculate streamwise vorticity. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100% corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements, as well as the time-resolved total pressures and velocities have helped to reveal a profound influence of the upstream stator vane on the size and shape of the rotor tip leakage flow. Finally, a novel particle image velocimetry (PIV) technique has been developed as a proof-of- concept. In contrast to PIV methods that have been typically been utilized for turbomachinery applications in the past, the method used for this study introduced the laser light through the same access window that was also used to image the flow. This new method addresses potential concerns related to the intrusive laser-introducing techniques that have typically been utilized by other authors in the past. Ultimately, the data collected for this project represent a unique data set which contributes to build a better understanding of the tip leakage flow field and its associated loss mechanisms. These data will facilitate future engine design goals leading to small blade heights in the rear stages of high pressure compressors and aid in the development of new blade designs which are desensitized to the performance penalties attributed to rotor tip leakage flows.

  5. Friction coefficient and effective interference at the implant-bone interface.

    Science.gov (United States)

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2015-09-18

    Although the contact pressure increases during implantation of a wedge-shaped implant, friction coefficients tend to be measured under constant contact pressure, as endorsed in standard procedures. Abrasion and plastic deformation of the bone during implantation are rarely reported, although they define the effective interference, by reducing the nominal interference between implant and bone cavity. In this study radial forces were analysed during simulated implantation and explantation of angled porous and polished implant surfaces against trabecular bone specimens, to determine the corresponding friction coefficients. Permanent deformation was also analysed to determine the effective interference after implantation. For the most porous surface tested, the friction coefficient initially increased with increasing normal contact stress during implantation and then decreased at higher contact stresses. For a less porous surface, the friction coefficient increased continually with normal contact stress during implantation but did not reach the peak magnitude measured for the rougher surface. Friction coefficients for the polished surface were independent of normal contact stress and much lower than for the porous surfaces. Friction coefficients were slightly lower for pull-out than for push-in for the porous surfaces but not for the polished surface. The effective interference was as little as 30% of the nominal interference for the porous surfaces. The determined variation in friction coefficient with radial contact force, as well as the loss of interference during implantation will enable a more accurate representation of implant press-fitting for simulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Effect of internal pressure and gas/liquid interface area on the CO mass transfer coefficient using hollow fibre membranes as a high mass transfer gas diffusing system for microbial syngas fermentation.

    Science.gov (United States)

    Yasin, Muhammad; Park, Shinyoung; Jeong, Yeseul; Lee, Eun Yeol; Lee, Jinwon; Chang, In Seop

    2014-10-01

    This study proposed a submerged hollow fibre membrane bioreactor (HFMBR) system capable of achieving high carbon monoxide (CO) mass transfer for applications in microbial synthesis gas conversion systems. Hydrophobic polyvinylidene fluoride (PVDF) membrane fibres were used to fabricate a membrane module, which was used for pressurising CO in water phase. Pressure through the hollow fibre lumen (P) and membrane surface area per unit working volume of the liquid (A(S)/V(L)) were used as controllable parameters to determine gas-liquid volumetric mass transfer coefficient (k(L)a) values. We found a k(L)a of 135.72 h(-1) when P was 93.76 kPa and AS/VL was fixed at 27.5m(-1). A higher k(L)a of 155.16 h(-1) was achieved by increasing AS/VL to 62.5m(-1) at a lower P of 37.23 kPa. Practicality of HFMBR to support microbial growth and organic product formation was assessed by CO/CO2 fermentation using Eubacterium limosum KIST612. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Long-term recovery of pressurized water reactors following a large break loss-of-coolant accident

    International Nuclear Information System (INIS)

    Fletcher, C.D.; Callow, R.A.

    1989-01-01

    The USNRC recently identified a possible safety concern for PWR's. Following the reflood phase of a large break loss-of-coolant accident, long-term cooling of the reactor core may not be ensured. Specifically, the concern is that, for a pump discharge cold leg break, the loop seals in the reactor coolant pump suction piping will refill with liquid and the post-reflood steam production may depress the liquid levels in the downflow sides of the loop seals. A loop seal depression would cause a corresponding depression of the core liquid levels and possibly a fuel rod heatup in the upper core region. This paper is intended as an introduction of the safety issue that: 1) describes the important aspects of the problem, 2) provides an initial analysis of the consequences, and 3) discusses ongoing work in this area. Because the elevation of the loop seals is near the mid-core elevation in plants of WE design, the concern is greatest for those plants. There is less concern for most plants of CE design, and likely no concern for plants of BW design. This issue was addressed by employing both steady-state and transient systems analysis approaches. Two approaches were used because of uncertainties regarding actual reactor coolant system behavior during the post-reflood period. The steady-state approach involved the development and application of a simple computer program to investigate reactor coolant system behavior assuming quiescent post-reflood conditions. The transient systems approach involved investigating this behavior using the RELAP5/MOD2 computer code and a comprehensive RELAP5 model of a WE PWR. The steady-state analysis indicated only a moderate fuel rod heatup is possible. The transient systems analysis indicated boiling and condensation-induced flow oscillations are sufficient to prevent fuel rod heatup. Analysis uncertainties are discussed. (orig./HP)

  8. Power coefficient anomaly in JOYO

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H

    1980-12-15

    Operation of the JOYO experimental fast reactor with the MK-I core has been divided into two phases: (1) 50 MWt power ascension and operation; and (2) 75 MWt power ascension and operation. The 50 MWt power-up tests were conducted in August 1978. In these tests, the measured reactivity loss due to power increases from 15 MWt to 50 MWt was 0.28% ..delta.. K/K, and agreed well with the predicted value of 0.27% ..delta.. K/K. The 75 MWt power ascension tests were conducted in July-August 1979. In the process of the first power increase above 50 MWt to 65 MWt conducted on July 11, 1979, an anomalously large negative power coefficient was observed. The value was about twice the power coefficient values measured in the tests below 50 MW. In order to reproduce the anomaly, the reactor power was decreased and again increased up to the maximum power of 65 MWt. However, the large negative power coefficient was not observed at this time. In the succeeding power increase from 65 MWt to 75 MWt, a similar anomalous power coefficient was again observed. This anomaly disappeared in the subsequent power ascensions to 75 MWt, and the magnitude of the power coefficient gradually decreased with power cycles above the 50 MWt level.

  9. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Thermo- and fluid-dynamic effects

    Energy Technology Data Exchange (ETDEWEB)

    Seeliger, André, E-mail: a.seeliger@hszg.de [Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany); Alt, Sören; Kästner, Wolfgang; Renger, Stefan [Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany); Kryk, Holger; Harm, Ulrich [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany)

    2016-08-15

    Highlights: • Borated coolant supports corrosion at zinc-coated installations in PWR after LOCA. • Dissolved zinc is injected into core by ECCS during sump recirculation phase. • Corrosion products can reach and settle at further downstream components. • Corrosion products can cause head losses at spacers and influence decay heat removal. • Preventive procedures were tested at semi-technical scale facilities. - Abstract: Within the framework of the German reactor safety research, generic experimental investigations were carried out aiming at thermal-hydraulic consequences of physicochemical mechanisms, caused by dissolution of zinc in boric acid during corrosion processes at hot-dip galvanized surfaces of containment internals at lower coolant temperatures and the subsequent precipitation of solid zinc borates in PWR core regions of higher temperature. This constellation can occur during sump recirculation operation of ECCS after LOCA. Hot-dip galvanized compounds, which are installed inside a PWR containment, may act as zinc sources. Getting in contact with boric acid coolant, zinc at their surfaces is released into coolant in form of ions due to corrosion processes. As a long-term behavior resp. over a time period of several days, metal layers of zinc and zinc alloys can dissolve extensively. First fundamental studies at laboratory scale were done at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR). Their experimental results were picked up for the definition of boundary conditions for experiments at semi-technical scale at the Hochschule Zittau/Görlitz (HSZG). Electrical heating rods with zircaloy cladding tubes have been used as fuel rod simulators. As near-plant core components, a 3 × 3 configuration of heating rods (HRC) and a shortened, partially heatable PWR fuel assembly dummy were applied into cooling circuits. The HRC module includes segments of spacers for a suitable representation of a heating channel geometry. Formations of different solid

  10. Perdas endógenas e coeficientes de absorção aparente e real do magnésio em caprinos Endogenous losses and coefficients of apparent and true absorption of magnesium in goats

    Directory of Open Access Journals (Sweden)

    Claudete Regina Alcalde

    1999-01-01

    Full Text Available Os objetivos deste trabalho foram determinar a absorção aparente, estimar as perdas endógenas fecais e a absorção real do Mg e determinar a ingestão ad libitum da água de beber e a concentração de Mg no soro sangüíneo de caprinos da raças Anglonubiana (AN e Saanen (SN. Foram usados doze caprinos, seis de cada raça, com 19,8 kg PV médio. Dietas semipurificadas (baixo teor de Mg à base de quirera de arroz, glúten de milho e celulose foram suplementadas com MgO, para se obterem os níveis de 0,05 (sem supplementação 0,20 e 0,35% Mg (%MS. Os níveis de Mg influenciaram os coeficientes de absorção aparente de Mg e Ca, com valores médios de 57,8; 73,9; e 73,2% para Mg e 55,7; 39,6; e 49,5% para Ca, para dietas com níveis 0,05; 0,20; e 0,35% de Mg, respectivamente. Entretanto, para os coeficientes de absorção aparente de P, Na e K, não houve efeito de níveis de Mg na dieta. Os resultados de absorção real de Mg apresentaram interação de níveis de Mg e raças. A média para raça NA, no nível 0,05% Mg, foi de 61,0% e para os níveis 0,20 e 0,35% Mg, 77,2 e 73,2%, respectivamente. Entretanto, para a raça SN, as médias foram 73,3; 75,5; e 76,0%, para os mesmos níveis, sem diferenças. A digestibilidade de matéria seca, proteína bruta e extrato não-nitrogenado diminuiu com os níveis crescentes de Mg nas dietas. As excreções fecais (7,0; 20,8; e 34,4 mg/kg PV0,75.d e urinárias (3,9; 30,8; e 44,6 mg/kg PV0,75.d de Mg elevaram-se com o aumento dos níveis crescentes de Mg nas dietas. Houve, também, influência dos níveis de Mg dietético sobre as concentrações de Mg do soro sangüíneo (1,74; 2,23; e 2,80 mg/dL para níveis de 0,05; 0,20; e 0,35% de Mg, respectivamente.The objectives of this experiment were to determine the apparent absorption, to estimate the endogenous fecal losses and the true absorption of Mg and to determine the ad libitum drinking water ingestion and the Mg serum concentration for Anglonubian

  11. An on-line pressurizer surveillance system design to prevent small-break loss-of-coolant accidents through power-operated relief valves using a microcomputer

    International Nuclear Information System (INIS)

    Lee, J.H.; Chang, S.H.

    1987-01-01

    A small-break loss-of-coolant accident (LOCA) caused by a stuck-open power-operated relief valve is one of the important contributors to nuclear power plant risk. A pressurizer surveillance system was designed to use a microcomputer to prevent the malfunction of the system; the effect of this improvement has been assessed through probabilistic risk assessment. The microcomputer diagnoses the malfunction of the system by a process-checking method and automatically performs the backup action related to each malfunction. This improvement means that we can correctly diagnose ''spurious opening,'' ''failure to reclose,'' and ''small-break LOCA,'' which are difficult for operators to diagnose quickly and correctly, and by taking automatic backup action one can reduce the probability of human error

  12. Pregnancy Loss and Miscarriage

    Science.gov (United States)

    ... D linked to miscarriage among women with prior pregnancy loss Release: Anti-HIV drug combination does not increase preterm birth risk, study suggests Release: Elevated blood pressure before pregnancy may increase chance of pregnancy loss All related ...

  13. The loss of essential oil components induced by the Purge Time in the Pressurized Liquid Extraction (PLE) procedure of Cupressus sempervirens.

    Science.gov (United States)

    Dawidowicz, Andrzej L; Czapczyńska, Natalia B; Wianowska, Dorota

    2012-05-30

    The influence of different Purge Times on the effectiveness of Pressurized Liquid Extraction (PLE) of volatile oil components from cypress plant matrix (Cupressus sempervirens) was investigated, applying solvents of diverse extraction efficiencies. The obtained results show the decrease of the mass yields of essential oil components as a result of increased Purge Time. The loss of extracted components depends on the extrahent type - the greatest mass yield loss occurred in the case of non-polar solvents, whereas the smallest was found in polar extracts. Comparisons of the PLE method with Sea Sand Disruption Method (SSDM), Matrix Solid-Phase Dispersion Method (MSPD) and Steam Distillation (SD) were performed to assess the method's accuracy. Independent of the solvent and Purge Time applied in the PLE process, the total mass yield was lower than the one obtained for simple, short and relatively cheap low-temperature matrix disruption procedures - MSPD and SSDM. Thus, in the case of volatile oils analysis, the application of these methods is advisable. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. 3D Simulation of a Loss of Vacuum Accident (LOVA in ITER (International Thermonuclear Experimental Reactor: Evaluation of Static Pressure, Mach Number, and Friction Velocity

    Directory of Open Access Journals (Sweden)

    Jean-François Ciparisse

    2018-04-01

    Full Text Available ITER (International Thermonuclear Experimental Reactor is a magnetically confined plasma nuclear reactor. Inside it, due to plasma disruptions, the formation of neutron-activated powders, which are essentially made out of tungsten and beryllium, occurs. As many windows for diagnostics are present on the reactor, which operates at very low pressure, a LOVA (Loss of Vacuum Accident could be possible and may lead to dust mobilisation and a toxic and radioactive fallout inside the plant. This study is aimed at reproducing numerically the first seconds of a LOVA in ITER, in order to get information about the dust resuspension risk. This work has been carried out by means of a CFD (Computational Fluid Dynamics simulation of the beginning of the pressurisation transient inside the whole Tokamak. It has been found that the pressurization transient is extremely slow, and that the friction speed on the walls is very high, and therefore a high mobilization risk of the dust is expected on the entire internal surface of the reactor. It has been observed that a LOVA in a real-scale reactor is more severe than the one reproduced in reduced-scale facilities, as STARDUST-U, because the speeds are higher, and the dust resuspension capacity of the flow is greater.

  15. Gentilly-2 NPP - Concrete aging effects on long term pre-stress losses and propagation of concrete cracking due to pressure testing

    International Nuclear Information System (INIS)

    Gocevski, V.

    2011-01-01

    This paper presents the results of the study intended to evaluate the post-tension long term losses and propagation of cracks in the envelope of Gentilly-2 Nuclear Power Plant reactor building. The numerical simulation of concrete, that takes into account elastic as well as inelastic strains due to loading, shrinkage strains due to drying or cooling and inelastic strains from alkali-aggregate reaction (AAR) related swelling, is explained. The simultaneous contribution of AAR, shrinkage and creep, are simulated using an enhanced elastic-plastic constitutive relation. The nonlinear relations are validated by comparing the numerically calculated strains with strain measurements from the extensometers placed in the concrete during the construction of the envelope. The post-tension losses/gains are evaluated for the vertical as well as horizontal cables. Also included is the result of pull-out test conducted on sample beam cast at the time of the reactor building construction with the same concrete mix, post-tension cable and force. Structural behaviour of the beam is simulated over the same period of time as the reactor building envelope. The test results are used also to calibrate the numerical model. The paper also includes discussion of the results obtained from the simulation of a standard internal high pressure test (145 kPa). The behavior of the reactor building envelope, prior to applied pressure, during the test and for the period of several months after the testing was simulated using an advanced numerical model and the results (strains) were compared with measured values. It was found that this method may be used as an approximate procedure for evaluation of post-tension losses/gains and assessment of propagation of cracking visible on the outside surfaces of the confinement building. In addition, a discussion of the negative effect of high post-tension on the air tightness of the confinement building of Gentilly-2. The comparison is made between the post

  16. Gentilly-2 NPP - Concrete aging effects on long term pre-stress losses and propagation of concrete cracking due to pressure testing

    Energy Technology Data Exchange (ETDEWEB)

    Gocevski, V. [Hydro-Quebe (Canada)

    2011-07-01

    This paper presents the results of the study intended to evaluate the post-tension long term losses and propagation of cracks in the envelope of Gentilly-2 Nuclear Power Plant reactor building. The numerical simulation of concrete, that takes into account elastic as well as inelastic strains due to loading, shrinkage strains due to drying or cooling and inelastic strains from alkali-aggregate reaction (AAR) related swelling, is explained. The simultaneous contribution of AAR, shrinkage and creep, are simulated using an enhanced elastic-plastic constitutive relation. The nonlinear relations are validated by comparing the numerically calculated strains with strain measurements from the extensometers placed in the concrete during the construction of the envelope. The post-tension losses/gains are evaluated for the vertical as well as horizontal cables. Also included is the result of pull-out test conducted on sample beam cast at the time of the reactor building construction with the same concrete mix, post-tension cable and force. Structural behaviour of the beam is simulated over the same period of time as the reactor building envelope. The test results are used also to calibrate the numerical model. The paper also includes discussion of the results obtained from the simulation of a standard internal high pressure test (145 kPa). The behavior of the reactor building envelope, prior to applied pressure, during the test and for the period of several months after the testing was simulated using an advanced numerical model and the results (strains) were compared with measured values. It was found that this method may be used as an approximate procedure for evaluation of post-tension losses/gains and assessment of propagation of cracking visible on the outside surfaces of the confinement building. In addition, a discussion of the negative effect of high post-tension on the air tightness of the confinement building of Gentilly-2. The comparison is made between the post

  17. Literature investigation of air/steam ingress through small cracks in concrete wall under pressure differences

    International Nuclear Information System (INIS)

    Jiang, J.T.

    2008-01-01

    Traditionally within CANDU safety analysis, a loss coefficient of ∼2.8 is used to characterize turbulent flow leakage through narrow, sharp-edged cracks into, and out of Steam Protected Rooms (SPRs). In the event of main steam line break (MSLB), the pressure differences observed between SPRs and the surrounding area of the powerhouse range from 0.01kPa to 0.1 kPa. The relatively low pressure differences, coupled with narrow crack sizes, for instance, below 1 mm, may result in laminar flow leakage pathways as opposed to the turbulent variety assumed in analysis. The main purpose of this paper is thus (a) to calculate the loss coefficient for laminar flow through small cracks; and (b) to assess the effect of steam ingress to SPRs when the flow through some or all of the room leakage area is assumed to be laminar. Based on the literature review, the loss coefficient for laminar flow, through 1 mm crack size at 0.1 kPa pressure difference, ranges from 10 to about 65. This value represents an increase in loss coefficient of 3 ∼ 22 times the loss coefficient used for SPR safety analysis. The actual volumetric leakage rate is therefore 3 ∼ 8 times smaller than the amount previously applied. This paper demonstrates how the traditional loss coefficient used in safety analysis is extremely conservative in the analysis of the SPRs steam ingress phenomenon. (author)

  18. Literature investigation of air/steam ingress through small cracks in concrete wall under pressure differences

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, J.T. [McMaster Univ., Engineering Physics Dept., Hamilton, Ontario (Canada)], E-mail: jiangj3@mcmaster.ca

    2008-07-01

    Traditionally within CANDU safety analysis, a loss coefficient of {approx}2.8 is used to characterize turbulent flow leakage through narrow, sharp-edged cracks into, and out of Steam Protected Rooms (SPRs). In the event of main steam line break (MSLB), the pressure differences observed between SPRs and the surrounding area of the powerhouse range from 0.01kPa to 0.1 kPa. The relatively low pressure differences, coupled with narrow crack sizes, for instance, below 1 mm, may result in laminar flow leakage pathways as opposed to the turbulent variety assumed in analysis. The main purpose of this paper is thus (a) to calculate the loss coefficient for laminar flow through small cracks; and (b) to assess the effect of steam ingress to SPRs when the flow through some or all of the room leakage area is assumed to be laminar. Based on the literature review, the loss coefficient for laminar flow, through 1 mm crack size at 0.1 kPa pressure difference, ranges from 10 to about 65. This value represents an increase in loss coefficient of 3 {approx} 22 times the loss coefficient used for SPR safety analysis. The actual volumetric leakage rate is therefore 3 {approx} 8 times smaller than the amount previously applied. This paper demonstrates how the traditional loss coefficient used in safety analysis is extremely conservative in the analysis of the SPRs steam ingress phenomenon. (author)

  19. Aplicação de CFD para o cálculo de coeficientes de pressão externos nas aberturas de um edifício = Application of CFD simulations for the calculation of external wind pressure coefficients on openings of a building

    NARCIS (Netherlands)

    Cóstola, D.; Alucci, M.P.

    2011-01-01

    Pressure coefficients (Cp) are a key parameter in the study of wind-driven natural ventilation in buildings. This paper reports the results of a research study aimed at evaluating the feasility of using CFD (Computational Fluid Dynamics) to obtain Cp data and also evaluating the importance of some

  20. Heat loss from Buildings

    DEFF Research Database (Denmark)

    Karlsson, Kenneth; Næraa, Rikke

    1997-01-01

    Determination of heat loss coefficients for buildings in Denmark. The coefficient are determined for 15 building groups and 3 year intervals. They are based on the BBR-registre and assumptions of U-values(W/K*m2)and computed in a simple spreed sheet model.The results are used in the REVEILLE...

  1. Thermal-Hydraulic Integral Effect Test with ATLAS for an Intermediate Break Loss of Coolant Accident at a Pressurizer Surge Line

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyoung Ho; Seok Cho; Park, Hyun Sik; Choi, Nam Hyun; Park, Yu Sun; Kim, Jong Rok; Bae, Byoung Uhn; Kim, Yeon Sik; Kim, Kyung Doo; Choi, Ki Yong; Song, Chul Hwa [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The main objectives of this test were not only to provide physical insight into the system response of the APR1400 during the pressurizer surge line break accident but also to produce an integral effect test data to validate the SPACE code. In order to simulate a double-ended guillotine break of a pressurizer surge line in the APR1400, the IB-SUR-01R test was performed with ATLAS. The major thermal-hydraulic phenomena such as the system pressures, the collapsed water levels, and the break flow rate were presented and discussed. Despite the core was uncovered, no excursion in the cladding temperature was observed. The pressurizer surge line break can be classified as a hot leg break from a break location point of view. Compared with a cold leg break, coolability in the core may be better in case of a hot leg break due to the enhanced flow in the core region. This integral effect test data will be used to evaluate the prediction capability of existing safety analysis codes of the MARS and the RELAP5 as well as the SPACE code. Furthermore, this data can be utilized to identify any code deficiency for an IBLOCA simulation, especially for DVI-adapted plants. Redefinition of break size for design basis accident (DBA) based on risk information is being extensively investigated due to the potential for safety benefits and unnecessary burden reduction from current LBLOCA (large break loss of coolant accident)-based ECC (Emergency Core Cooling) Acceptance Criteria. As a transition break size (TBS), the rupture of medium-size pipe is considered to be more important than ever in risk-informed regulation (RIR)-relevant safety analysis. As plants age, are up-rated, and continue to seek improved operating efficiencies, the small break and intermediate break LOCA (IBLOCA) can become a concern. In particular, IBLOCA with DVI (Direct Vessel Injection) features will be addressed to support redefinition of a design-basis LOCA. With an aim of expanding code validation to address small

  2. Evaluation of the radiative transfer in the core of a Pressurized Water Reactor (PWR) during the reflooding step of a Loss Of Coolant Accident (LOCA)

    International Nuclear Information System (INIS)

    Gerardin, J.

    2012-01-01

    We developed a method of resolution of radiative transfer inside a medium of vapor-droplets surrounded by hot walls, in order to couple it with a simulation of the flow at the CFD scale. The scope is the study of the cooling of the core of nuclear reactor following a Loss Of Coolant Accident (LOCA). The problem of radiative transfer can be cut into two sub problems, one concerning the evaluation of the radiative properties of the medium and a second concerning the solution of the radiative transfer equation. The radiative properties of the droplets have been computed with the use of the Mie Theory and those of the vapor have been computed with a Ck model. The medium made of vapor and droplets is an absorbing, anisotropically scattering, emissive, non grey, non homogeneous medium. Hence, owing to the possible variations of the flow properties (diameter and volumetric fraction of the droplets, temperature and pressure of the vapor), the medium can be optically thin or thick. Consequently, a method is required which solves the radiative transfer accurately, with a moderate calculation time for all of these prerequisites. The IDA has been chosen, derived from the well-known P1-approximation. Its accuracy has been checked on academical cases found in the literature and by comparison with experimental data. Simulations of LOCA flows have been conducted taking account of the radiative transfer, evaluating the radiative fluxes and showing that radiative transfer influence cannot be neglected. (author)

  3. Effect of external pressure environment on the internal noise level due to a source inside a cylindrical tank

    Science.gov (United States)

    Clevenson, S. A.; Roussos, L. A.

    1984-01-01

    A small cylindrical tank was used to study the effect on the noise environment within a tank of conditions of atmospheric (sea level) pressure or vacuum environments on the exterior. Experimentally determined absorption coefficients were used to calculate transmission loss, transmissibility coefficients and the sound pressure (noise) level differences in the interior. The noise level differences were also measured directly for the two exterior environments and compared to various analytical approximations with limited agreement. Trend study curves indicated that if the tank transmission loss is above 25 dB, the difference in interior noise level between the vacuum and ambient pressure conditions are less than 2 dB.

  4. Transport Coefficients of Fluids

    CERN Document Server

    Eu, Byung Chan

    2006-01-01

    Until recently the formal statistical mechanical approach offered no practicable method for computing the transport coefficients of liquids, and so most practitioners had to resort to empirical fitting formulas. This has now changed, as demonstrated in this innovative monograph. The author presents and applies new methods based on statistical mechanics for calculating the transport coefficients of simple and complex liquids over wide ranges of density and temperature. These molecular theories enable the transport coefficients to be calculated in terms of equilibrium thermodynamic properties, and the results are shown to account satisfactorily for experimental observations, including even the non-Newtonian behavior of fluids far from equilibrium.

  5. Measurements of the Drag Coefficient of Simulated Micrometeoroids

    Science.gov (United States)

    DeLuca, M.; Munsat, T.; Sternovsky, Z.

    2017-12-01

    The dust accelerator facility operated at the University of Colorado is used to simulate meteoric ablation, including measuring the ionization efficiency over a wide range of velocities (e.g., DeLuca et al., Planet. Space Sci., submitted, 2017). This presentation reports on the most recent experimental measurements of the drag coefficient that determines the particles' slowdown from their frictional interaction with the atmosphere. The measurements indicate that meteors experience considerably more slowdown than usually assumed. The simulated meteors consisted of submicron sized aluminum particles shot into an air chamber held at 200 mTorr pressure at velocities between 1 - 10 km/s using the dust accelerator and meteor ablation facility. The slowdown is calculated from precise timing measurements made using pickup tube detectors placed upstream and near the entrance to the air chamber, and an impact detector inside the air chamber at the downstream end of the chamber. Supporting modeling calculations show that the particles have little or no mass loss during their interaction with air and thus constant radius can be assumed. Preliminary results for the drag coefficient calculated from these timing measurements reveal that the aluminum particles have a drag coefficient of 1.51 ± 0.24 in air, which is higher than typically assumed in meteoric ablation models (usually 0.5 to 1), indicating that meteors may experience more air drag than previously assumed. More detailed measurements over a wider parameter range are underway.

  6. Evolution of transverse piezoelectric response of lead zirconate titanate ceramics under hydrostatic pressure

    International Nuclear Information System (INIS)

    Li Fei; Xu Zhuo; Wei Xiaoyong; Gao Junjie; Zhang, Chonghui; Yao Xi; Jin Li

    2009-01-01

    The piezoelectric properties of 31-mode resonators of lead zirconate titanate ceramics under hydrostatic pressure from 0.1 to 325 MPa were evaluated by a fitting method, in which mechanical loss was taken into account. Our results based on the fitting method showed a hydrostatic pressure independent tendency of the piezoelectric coefficient and the electromechanical coupling factor because the adopted PZT ceramic can be considered as a linear system in our experiment, while two misleading tendencies of piezoelectric coefficient were obtained based on the resonance method when ignoring the contribution of the mechanical loss. (fast track communication)

  7. Remifentanil Reduces Blood Loss During Orthognathic Surgery.

    Science.gov (United States)

    Matsuura, Nobuyuki; Okamura, Taiki; Ide, Satoko; Ichinohe, Tatsuya

    2017-01-01

    Remifentanil is reported to reduce oral tissue blood flow. We performed a retrospective investigation using logistic regression analysis of anesthesia records to investigate whether the use of remifentanil infusion in a balanced anesthesia technique was useful as a primary technique to reduce blood loss during orthognathic surgery. Subjects were 80 patients who underwent Le Fort I osteotomy and sagittal split ramus osteotomy of the mandible. The variables included gender, age, weight, type of maintenance anesthetic, type and dose or infusion rate of opioid, mean systolic blood pressure (SBP-mean), coefficient of variation of systolic blood pressure (CVSBP) during surgery, mean heart rate (HR-mean), duration of surgery, total blood loss, volume of infusion used, amount of local anesthetic used, body temperature, and urine output. Gender, type of maintenance anesthetic, type of opioid, SBP-mean, CVSBP, HR-mean, and duration of surgery were used as candidates for independent variables. Logistic regression analysis was performed for the selected independent variables with the total blood loss as the dependent variable. The factors associated with the reduction of blood loss were the use of remifentanil (odds ratio, 3.112; 95% CI, 1.166-8.307; P = .023) and smaller CVSBP (odds ratio, 2.747; 95% CI, 1.07-7.053; P = .036). Use of remifentanil and smaller CVSBP were associated with a reduction of blood loss during orthognathic surgery.

  8. A pressure drop model for PWR grids

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dong Seok; In, Wang Ki; Bang, Je Geon; Jung, Youn Ho; Chun, Tae Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    A pressure drop model for the PWR grids with and without mixing device is proposed at single phase based on the fluid mechanistic approach. Total pressure loss is expressed in additive way for form and frictional losses. The general friction factor correlations and form drag coefficients available in the open literatures are used to the model. As the results, the model shows better predictions than the existing ones for the non-mixing grids, and reasonable agreements with the available experimental data for mixing grids. Therefore it is concluded that the proposed model for pressure drop can provide sufficiently good approximation for grid optimization and design calculation in advanced grid development. 7 refs., 3 figs., 3 tabs. (Author)

  9. A pressure drop model for PWR grids

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Dong Seok; In, Wang Ki; Bang, Je Geon; Jung, Youn Ho; Chun, Tae Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A pressure drop model for the PWR grids with and without mixing device is proposed at single phase based on the fluid mechanistic approach. Total pressure loss is expressed in additive way for form and frictional losses. The general friction factor correlations and form drag coefficients available in the open literatures are used to the model. As the results, the model shows better predictions than the existing ones for the non-mixing grids, and reasonable agreements with the available experimental data for mixing grids. Therefore it is concluded that the proposed model for pressure drop can provide sufficiently good approximation for grid optimization and design calculation in advanced grid development. 7 refs., 3 figs., 3 tabs. (Author)

  10. Attenuation coefficients of soils

    International Nuclear Information System (INIS)

    Martini, E.; Naziry, M.J.

    1989-01-01

    As a prerequisite to the interpretation of gamma-spectrometric in situ measurements of activity concentrations of soil radionuclides the attenuation of 60 to 1332 keV gamma radiation by soil samples varying in water content and density has been investigated. A useful empirical equation could be set up to describe the dependence of the mass attenuation coefficient upon photon energy for soil with a mean water content of 10%, with the results comparing well with data in the literature. The mean density of soil in the GDR was estimated at 1.6 g/cm 3 . This value was used to derive the linear attenuation coefficients, their range of variation being 10%. 7 figs., 5 tabs. (author)

  11. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

    Science.gov (United States)

    Leumann, Andre; Fortuna, Rafael; Leonard, Tim; Valderrabano, Victor; Herzog, Walter

    2015-01-01

    The menisci are thought to modulate load transfer and to absorb shocks in the knee joint. No study has experimentally measured the meniscal functions in the intact, in vivo joint loaded by physiologically relevant muscular contractions. Right knee joints of seven New Zealand white rabbits were loaded using isometric contractions of the quadriceps femoris muscles controlled by femoral nerve stimulation. Isometric knee extensor torques at the maximal and two submaximal force levels were performed at knee angles of 70°, 90°, 110°, and 130°. Patellofemoral and tibiofemoral contact areas and pressure distributions were measured using Fuji Presensor film inserted above and below the menisci and also with the menisci removed. Meniscectomy was associated with a decrease in tibiofemoral contact area ranging from 30 to 70% and a corresponding increase in average contact pressures. Contact areas measured below the menisci were consistently larger than those measured on top of the menisci. Contact areas in the patellofemoral joint (PFJ), and peak pressures in tibiofemoral and PFJs, were not affected by meniscectomy. Contact areas and peak pressures in all joints depended crucially on knee joint angle and quadriceps force: The more flexed the knee joint was, the larger were the contact areas and the higher were the peak pressures. In agreement with the literature, removal of the menisci was associated with significant decreases in tibiofemoral contact area and corresponding increases in average contact pressures, but surprisingly, peak pressures remained unaffected, indicating that the function of the menisci is to distribute loads across a greater contact area.

  12. Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size

    Directory of Open Access Journals (Sweden)

    Jagdish C. Mohan

    2017-01-01

    Full Text Available Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA, wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6 cm2 respectively measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75–85%. Such a phenomenon has not been reported in vivo for these two valve designs.

  13. Significant intra-valvular pressure loss across EPIC SUPRA and perimount magna supra-annular designed aortic bioprostheses in patients with normal aortic size.

    Science.gov (United States)

    Mohan, Jagdish C; Mohan, Vishwas; Shukla, Madhu; Sethi, Arvind

    Doppler-derived trans-prosthetic gradients are higher and the estimated effective valve area is smaller than the catheter-derived and directly measured hemodynamic values, mostly due to pressure recovery phenomenon. Pressure recovery to a varying extent is common to all prosthetic heart valves including bioprostheses. Pressure recovery-related differences are usually small except in patients with bileaflet metallic prosthesis, wherein high-pressure local jets across central orifice have been documented since long back and also in patients with narrow aortic root. We describe two patients with normally functioning stented aortic bioprostheses with supra-annular design (EPIC SUPRA and PERIMOUNT MAGNA), wherein very high trans-prosthetic gradients and critically reduced estimated effective valve orifice areas in presence of normal aortic size were consistently recorded over long periods of follow-up. The valve leaflets, however had normal excursion, were thin, opened with a triangular or oblong shape and had expected geometric valve area (1.7 and 1.6cm 2 respectively) measured by 3D trans-oesophageal echocardiographic planimetry. Pressure recovery upstream the valves accounted for 20% and 12% of total pressure gradients respectively. Dominant site for pressure drop was intra-valvular (75-85%). Such a phenomenon has not been reported in vivo for these two valve designs. Copyright © 2016. Published by Elsevier B.V.

  14. Pressure distribution over tube surfaces of tube bundle subjected to two phase cross flow

    International Nuclear Information System (INIS)

    Sim, Woo Gun

    2013-01-01

    Two phase vapor liquid flows exist in many shell and tube heat exchangers such as condensers, evaporators and nuclear steam generators. To understand the fluid dynamic forces acting on a structure subjected to a two phase flow, it is essential to obtain detailed information about the characteristics of a two phase flow. The characteristics of a two phase flow and the flow parameters were introduced, and then, an experiment was performed to evaluate the pressure loss in the tube bundles and the fluid dynamic force acting on the cylinder owing to the pressure distribution. A two phase flow was pre mixed at the entrance of the test section, and the experiments were undertaken using a normal triangular array of cylinders subjected to a two phase cross flow. The pressure loss along the flow direction in the tube bundles was measured to calculate the two phase friction multiplier, and the multiplier was compared with the analytical value. Furthermore, the circular distributions of the pressure on the cylinders were measured. Based on the distribution and the fundamental theory of two phase flow, the effects of the void fraction and mass flux per unit area on the pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure coefficient and the drag coefficient were evaluated. The drag coefficient was calculated by integrating the measured pressure on the tube by a numerical method. It was found that for low mass fluxes, the measured two phase friction multipliers agree well with the analytical results, and good agreement for the effect of the void fraction on the drag coefficients, as calculated by the measured pressure distributions, is shown qualitatively, as compared to the existing experimental results

  15. Beam-loss induced pressure rise of Large Hadron Collider collimator materials irradiated with 158  GeV/u In^{49+} ions at the CERN Super Proton Synchrotron

    Directory of Open Access Journals (Sweden)

    E. Mahner

    2004-10-01

    Full Text Available During heavy ion operation, large pressure rises, up to a few orders of magnitude, were observed at CERN, GSI, and BNL. The dynamic pressure rises were triggered by lost beam ions that impacted onto the vacuum chamber walls and desorbed about 10^{4} to 10^{7} molecules per ion. The deterioration of the dynamic vacuum conditions can enhance charge-exchange beam losses and can lead to beam instabilities or even to beam abortion triggered by vacuum interlocks. Consequently, a dedicated measurement of heavy-ion induced molecular desorption in the GeV/u energy range is important for Large Hadron Collider (LHC ion operation. In 2003, a desorption experiment was installed at the Super Proton Synchrotron to measure the beam-loss induced pressure rise of potential LHC collimator materials. Samples of bare graphite, sputter coated (Cu, TiZrV graphite, and 316 LN (low carbon with nitrogen stainless steel were irradiated under grazing angle with 158  GeV/u indium ions. After a description of the new experimental setup, the results of the pressure rise measurements are presented, and the derived desorption yields are compared with data from other experiments.

  16. The Truth About Ballistic Coefficients

    OpenAIRE

    Courtney, Michael; Courtney, Amy

    2007-01-01

    The ballistic coefficient of a bullet describes how it slows in flight due to air resistance. This article presents experimental determinations of ballistic coefficients showing that the majority of bullets tested have their previously published ballistic coefficients exaggerated from 5-25% by the bullet manufacturers. These exaggerated ballistic coefficients lead to inaccurate predictions of long range bullet drop, retained energy and wind drift.

  17. NRC Information Notice No. 92-67: Deficiency in design modifications to address failures of Hiller actuators upon a gradual loss of air pressure

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1993-01-01

    On January 7, 1992, Carolina Power and Light Company (Shearon Harris Plant) components associated with the air supply to the actuators of the three main feedwater preheater bypass isolation valves were not qualified for a Q class application. Specifically, the failure of the air pump in the non-Q Class, non-seismic instrument air supply to the valve actuator accumulator could prevent pressure switches upstream of the air pump from detecting slow leakage in the Q Class, seismic portion of the actuator air lines. The pressure switches were installed to ensure valve closure by sending an automatic close signal if the instrument air system pressure (upstream of the actuator air pump) dropped to 66 psig as discussed in IN 82-25. The main feedwater preheater bypass isolation valves function as containment isolation valves upon receipt of a feedwater isolation signal. The function of the air pump is to raise the normal instrument air supply pressure from 70 to 100 psig to approximately 150 psig. If accumulator pressure drops from 150 psig to 122 psig, the main feedwater preheater bypass isolation valve may not close within 10 seconds. If pressure drops to a value as low as 20 psig, it may not be sufficient to close the main feedwater preheater bypass isolation valve and keep it closed against the maximum differential pressure across the valve seat. Upon discovery of this condition, Shearon Harris established a surveillance interval for verifying that the actuators' components were functioning properly and that the accumulators were fully pressurized. On January 12, 1992, non-Q components were replaced with suitable components and testing was completed satisfactorily

  18. Evaluation of containment peak pressure and structural response for a large-break loss-of-coolant accident in a VVER-440/213 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, B.W.; Sienicki, J.J.; Kulak, R.F.; Pfeiffer, P.A. [Argonne National Lab., IL (United States); Voeroess, L.; Techy, Z. [VEIKI Inst. for Electric Power Research, Budapest (Hungary); Katona, T. [Paks Nuclear Power Plant (Hungary)

    1998-07-01

    A collaborative effort between US and Hungarian specialists was undertaken to investigate the response of a VVER-440/213-type NPP to a maximum design-basis accident, defined as a guillotine rupture with double-ended flow from the largest pipe (500 mm) in the reactor coolant system. Analyses were performed to evaluate the magnitude of the peak containment pressure and temperature for this event; additional analyses were performed to evaluate the ultimate strength capability of the containment. Separate cases were evaluated assuming 100% effectiveness of the bubbler-condenser pressure suppression system as well as zero effectiveness. The pipe break energy release conditions were evaluated from three sources: (1) FSAR release rate based on Soviet safety calculations, (2) RETRAN-03 analysis and (3) ATHLET analysis. The findings indicated that for 100% bubbler-condenser effectiveness the peak containment pressures were less than the containment design pressure of 0.25 MPa. For the BDBA case of zero effectiveness of the bubbler-condenser system, the peak pressures were less than the calculated containment failure pressure of 0.40 MPa absolute.

  19. Hearing loss

    Science.gov (United States)

    Decreased hearing; Deafness; Loss of hearing; Conductive hearing loss; Sensorineural hearing loss; Presbycusis ... Symptoms of hearing loss may include: Certain sounds seeming too loud Difficulty following conversations when two or more people are talking ...

  20. Simulation of a scenario of total loss of external and internal power (Sbo) for different vent pressures of the containment of a BWR-5

    International Nuclear Information System (INIS)

    Cardenas V, J.; Mugica R, C. A.; Godinez S, V.

    2014-10-01

    The simulation of a Station Black Out (Sbo) was realized with intervention of the vent containment by means of a rigid vent coming from the dry-well and that discharges directly to the atmosphere, with the MELCOR code version 2.1. This scenario was carried out for a BWR-5 and containment type Mark II, with a thermal power of 2317 MWt similar to the reactor of nuclear power plant of Laguna Verde. For this scenario was considered as only available system for coolant injection to the reactor to the Reactor Core Isolation Cooling (Rcic), which remained operating 4 hours with batteries bank. The Security and Relief Valves (SR V) were considered functional (by simplicity) and that they mechanically do not exceed their capacity to liberate pressure due to the performances in their safety way. The operator maneuver to perform the SR V and to de pressurize the vessel until the pressure (13 kg/cm 2 ) to operate the low pressure systems was modeled. The results cover approximately 48 hours (172000 seconds), time in which was observed the behavior of the level and pressure in the vessel. Also the scenario evolution was analyzed to different vent pressures of the primary containment (2.0, 3.0, 4.5, 6.0, and 10.0 kg/cm 2 ), the temperature profiles of the dry-well, the hydrogen accumulation in the containment, the radio-nuclides liberation through rigid vent to the atmosphere and the inventory of these. In this work an analysis of the pressure behavior in the primary containment is presented, with the purpose of minimizing liberated fission products to the environment. (Author)

  1. Pressure Drop Test of Hybrid Mixing Vane Spacer Grid

    Energy Technology Data Exchange (ETDEWEB)

    Oh, D. S.; Chang, S. K.; Kim, B. D.; Chun, S. Y.; Chun, T. H

    2007-08-15

    The pressure loss test has been accomplished in the test section containing 5x5 rod bundle with a length of 2 m including 3 spacer grids. The test has been performed for the 5 kinds of spacer grids to compare the pressure loss characteristics: 1. Plain spacer grid which has the same body of the Hybrid but without vane (Plain), 2. Hybrid Vane spacer grid (Hybrid), 3. Hybrid-SC spacer grid which is constructed with coined, chamfered strip and is fabricated by spot welding, 4. Hybrid-LC spacer grid which is constructed with coined, chamfered strip and is fabricated by line welding along intersection line, 5. Westinghouse spacer grid with split vane (Plus-7). The pressure loss coefficient of the Plain, Hybrid, Hybrid-SC, Hybrid-LC, and Plus-7 spacer grid is 0.93, 1.15, 1.02, 1.04, and 1.08, respectively.

  2. A study on a characteristic of stem friction coefficient for motor operated flexible wedge gate valve

    International Nuclear Information System (INIS)

    Kim, Dae-Woong; Park, Sung-Geun; Lee, Sang-Guk; Kang, Shin-Cheul

    2009-01-01

    Stem friction coefficient is a coefficient that represents friction between thread leads of the stem and stem nut. It is an important factor to determine output thrust delivered from the actuator to the valve stem in assessing performance of motor operated valves. This study analyzes the effects of changes in differential pressure on stem friction coefficient, and determines the bounding value of stem friction coefficient. A dynamic test was conducted on multiple flexible wedge gate valves in various differential pressure conditions, and the test data was statistically analyzed to determine the bounding value. The results show that stem friction coefficient in middle and high differential pressure is influenced by fluid pressure, while stem friction coefficient in low differential pressure is almost not affected by fluid pressure. In addition, it is found that the bounding value of stem friction coefficient is higher in a closing stroke than in an opening stroke.

  3. Ego depletion and attention regulation under pressure: is a temporary loss of self-control strength indeed related to impaired attention regulation?

    Science.gov (United States)

    Englert, Chris; Zwemmer, Kris; Bertrams, Alex; Oudejans, Raôul R

    2015-04-01

    In the current study we investigated whether ego depletion negatively affects attention regulation under pressure in sports by assessing participants' dart throwing performance and accompanying gaze behavior. According to the strength model of self-control, the most important aspect of self-control is attention regulation. Because higher levels of state anxiety are associated with impaired attention regulation, we chose a mixed design with ego depletion (yes vs. no) as between-subjects and anxiety level (high vs. low) as within-subjects factor. Participants performed a perceptual-motor task requiring selective attention, namely, dart throwing. In line with our expectations, depleted participants in the high-anxiety condition performed worse and displayed a shorter final fixation on bull's eye, demonstrating that when one's self-control strength is depleted, attention regulation under pressure cannot be maintained. This is the first study that directly supports the general assumption that ego depletion is a major factor in influencing attention regulation under pressure.

  4. Mayer coefficients in two-dimensional Coulomb systems

    International Nuclear Information System (INIS)

    Speer, E.R.

    1986-01-01

    It is shown that, for neutral systems of particles of arbitrary charges in two dimensions, with hard cores, coefficients of the Mayer series for the pressure exist in the thermodynamic limit below certain thresholds in the temperature. The methods used here apply also to correlation functions and yield bounds on the asymptotic behavior of their Mayer coefficients

  5. Transport Coefficients for dense hard-disk systems

    NARCIS (Netherlands)

    Garcia-Rojo, R.; Luding, Stefan; Brey, J. Javier; Ooms, G.; Hoogendoorn, C.J.

    2007-01-01

    A study of the transport coefficients of a system of elastic hard disks, based on the use of Helfand-Einstein expressions is reported. The pressure, the viscosity, and the heat conductivity are examined for different density and system-size. While most transport coefficients agree with Enskog theory

  6. Correlation and prediction of gaseous diffusion coefficients.

    Science.gov (United States)

    Marrero, T. R.; Mason, E. A.

    1973-01-01

    A new correlation method for binary gaseous diffusion coefficients from very low temperatures to 10,000 K is proposed based on an extended principle of corresponding states, and having greater range and accuracy than previous correlations. There are two correlation parameters that are related to other physical quantities and that are predictable in the absence of diffusion measurements. Quantum effects and composition dependence are included, but high-pressure effects are not. The results are directly applicable to multicomponent mixtures.

  7. Ego depletion and attention regulation under pressure: Is a temporary loss of self-control strength indeed related to impaired attention regulation?

    NARCIS (Netherlands)

    Englert, C.; Zwemmer, K.; Bertrams, A.; Oudejans, R.R.D.

    2015-01-01

    In the current study we investigated whether ego depletion negatively affects attention regulation under pressure in sports by assessing participants' dart throwing performance and accompanying gaze behavior. According to the strength model of self-control, the most important aspect of self-control

  8. Experimental methodology for obtaining sound absorption coefficients

    Directory of Open Access Journals (Sweden)

    Carlos A. Macía M

    2011-07-01

    Full Text Available Objective: the authors propose a new methodology for estimating sound absorption coefficients using genetic algorithms. Methodology: sound waves are generated and conducted along a rectangular silencer. The waves are then attenuated by the absorbing material covering the silencer’s walls. The attenuated sound pressure level is used in a genetic algorithm-based search to find the parameters of the proposed attenuation expressions that include geometric factors, the wavelength and the absorption coefficient. Results: a variety of adjusted mathematical models were found that make it possible to estimate the absorption coefficients based on the characteristics of a rectangular silencer used for measuring the attenuation of the noise that passes through it. Conclusions: this methodology makes it possible to obtain the absorption coefficients of new materials in a cheap and simple manner. Although these coefficients might be slightly different from those obtained through other methodologies, they provide solutions within the engineering accuracy ranges that are used for designing noise control systems.

  9. Drag coefficient Variability and Thermospheric models

    Science.gov (United States)

    Moe, Kenneth

    Satellite drag coefficients depend upon a variety of factors: The shape of the satellite, its altitude, the eccentricity of its orbit, the temperature and mean molecular mass of the ambient atmosphere, and the time in the sunspot cycle. At altitudes where the mean free path of the atmospheric molecules is large compared to the dimensions of the satellite, the drag coefficients can be determined from the theory of free-molecule flow. The dependence on altitude is caused by the concentration of atomic oxygen which plays an important role by its ability to adsorb on the satellite surface and thereby affect the energy loss of molecules striking the surface. The eccentricity of the orbit determines the satellite velocity at perigee, and therefore the energy of the incident molecules relative to the energy of adsorption of atomic oxygen atoms on the surface. The temperature of the ambient atmosphere determines the extent to which the random thermal motion of the molecules influences the momentum transfer to the satellite. The time in the sunspot cycle affects the ambient temperature as well as the concentration of atomic oxygen at a particular altitude. Tables and graphs will be used to illustrate the variability of drag coefficients. Before there were any measurements of gas-surface interactions in orbit, Izakov and Cook independently made an excellent estimate that the drag coefficient of satellites of compact shape would be 2.2. That numerical value, independent of altitude, was used by Jacchia to construct his model from the early measurements of satellite drag. Consequently, there is an altitude dependent bias in the model. From the sparce orbital experiments that have been done, we know that the molecules which strike satellite surfaces rebound in a diffuse angular distribution with an energy loss given by the energy accommodation coefficient. As more evidence accumulates on the energy loss, more realistic drag coefficients are being calculated. These improved drag

  10. On the Kendall Correlation Coefficient

    OpenAIRE

    Stepanov, Alexei

    2015-01-01

    In the present paper, we first discuss the Kendall rank correlation coefficient. In continuous case, we define the Kendall rank correlation coefficient in terms of the concomitants of order statistics, find the expected value of the Kendall rank correlation coefficient and show that the later is free of n. We also prove that in continuous case the Kendall correlation coefficient converges in probability to its expected value. We then propose to consider the expected value of the Kendall rank ...

  11. Loss of Coolant Accident (LOCA) / Emergency Core Coolant System (ECCS Evaluation of Risk-Informed Margins Management Strategies for a Representative Pressurized Water Reactor (PWR)

    Energy Technology Data Exchange (ETDEWEB)

    Szilard, Ronaldo Henriques [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-09-01

    A Risk Informed Safety Margin Characterization (RISMC) toolkit and methodology are proposed for investigating nuclear power plant core, fuels design and safety analysis, including postulated Loss-of-Coolant Accident (LOCA) analysis. This toolkit, under an integrated evaluation model framework, is name LOCA toolkit for the US (LOTUS). This demonstration includes coupled analysis of core design, fuel design, thermal hydraulics and systems analysis, using advanced risk analysis tools and methods to investigate a wide range of results.

  12. Pregnancy Loss

    Science.gov (United States)

    ... To receive Pregnancy email updates Enter email Submit Pregnancy loss Pregnancy loss is a harsh reality faced ... have successful pregnancies. Expand all | Collapse all Why pregnancy loss happens As many as 10 to 15 ...

  13. Verification tests for GRAD, a computer program to predict nonuniform deformation and failure of Zr-2.5 wt percent Nb pressure tubes during a postulated loss-of-coolant accident

    International Nuclear Information System (INIS)

    Shewfelt, R.S.W.; Godin, D.P.

    1985-03-01

    During a postulated loss-of-coolant accident in a CANDU reactor, the temperature of the pressure tubes could rise sufficiently so that ballooning could occur. It is also likely that there would be a variation in temperature around the tube circumference, causing the deformation to be nonuniform. Since the deformation of the pressure tube controls how the core heat is transferred to the surrounding moderator, which is a large heat sink, a computer program, GRAD, has been developed to predict this nonuniform deformation. Numerous biaxial creep tests were done, where the temperature of internally pressurized sections of Zr-2.5 wt percent Nb pressure tubes were ramped to check the ability of GRAD to predict the resulting nonuniform deformation and possible tube failure. GRAD was successful in predicting the average transverse creep strain observed during the tests and the local transverse creep strain at the end of the tests. GRAD was also able to predict the failure time and average transverse creep strain at failure for all the specimens that failed

  14. Effects of synthetic oil in a compression refrigeration system using R410A. Part II: quality of heat transfer and pressure losses within the heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O.; Guillemet, P. [Ecole Polytechnique de l' Universite de Nantes (France). Laboratoire de Thermocinetique; Lebreton, J-M. [Electricite de France, Moret sur Loing (France)

    2003-11-01

    The consequences of the oil rejected by the compressor of a vapour-compression refrigeration system on the operation of the evaporator and condenser are analysed. The modelled prototype uses the mixture of HFC R410A and a synthetic polyolester (POE) oil. The rise of the amount of lubricant circulating in the system leads to a progressive change in the behaviour of the mixture of refrigerant and oil that, for the higher oil mass fraction, evolves like a zeotropic mixture. One also observes that the presence of lubricant is generally associated with a fall of the performances of the heat exchangers, except however in the evaporator where an optimum is observed when the quantity of oil is equal to 0.1% of the total mass of the mixture. Some conclusions are drawn about the choice of correlations for the calculation of the refrigerant side heat transfer coefficient in a plate evaporator. (author)

  15. Influences of mach number and flow incidence on aerodynamic losses of steam turbine blade

    International Nuclear Information System (INIS)

    Yoo, Seok Jae; Ng, Wing Fai

    2000-01-01

    An experiment was conducted to investigate the aerodynamic losses of high pressure steam turbine nozzle (526A) subjected to a large range of incident angles (-34 .deg. to 26 .deg. ) and exit Mach numbers (0.6 and 1.15). Measurements included downstream pitot probe traverses, upstream total pressure, and endwall static pressures. Flow visualization techniques such as shadowgraph and color oil flow visualization were performed to complement the measured data. When the exit Mach number for nozzles increased from 0.9 to 1.1 the total pressure loss coefficient increased by a factor of 7 as compared to the total pressure losses measured at subsonic conditions (M 2 <0.9). For the range of incidence tested, the effect of flow incidence on the total pressure losses is less pronounced. Based on the shadowgraphs taken during the experiment, it's believed that the large increase in losses at transonic conditions is due to strong shock/ boundary layer interaction that may lead to flow separation on the blade suction surface

  16. Comparação do Coeficiente Global de Perdas de Calor para casa de vegetação aquecida usando diferentes técnicas para eficiência energética Comparison of overall heat loss coefficient to warm greenhouse applying energy saving techiniques

    Directory of Open Access Journals (Sweden)

    Celso E. L. de Oliveira

    2006-08-01

    Full Text Available O Coeficiente Global de Perdas de Calor (U permite o equacionamento das necessidades térmicas de uma casa de vegetação climatizada. No presente trabalho, determinou-se esse coeficiente cujo referencial foi uma casa de vegetação localizada em Madri (Espanha, em que foram utilizadas medidas noturnas de temperatura do ar no interior, no exterior, bem como o consumo de energia para aquecimento. As comparações entre as técnicas de aquecimento utilizadas foram: solo radiante e aerotermos combinados com duas técnicas que visavam a promover melhor aproveitamento térmico, ou seja, a utilização de cobertura plástica formando dupla capa ou a utilização de túnel plástico. Os menores coeficientes foram conseguidos para a utilização de solo radiante com túnel e aerotermos com dupla capa com 7,19 W m-2 ºC-1 e 9,11 W m-2 ºC-1, respectivamente; o maior valor dentre os coeficientes nas condições estudadas foi 15,13 W m-2 ºC-1 ao considerar o uso de aerotermos sem utilização de plásticos. Conclui-se, portanto, que os resultados comprovam o melhor rendimento térmico para as técnicas ensaiadas.The Global Heat Loss Coefficient (U allows some answers about thermal requirements of climatic greenhouse. This trial determined this coefficient for a greenhouse in Madrid (Spain where night measurements of inside and outside air temperature as well as energy consumption to heat were used. Comparisons were accomplished among the used heating techniques as: radiant floor and heat fan combined with two techniques aiming to promote a better thermal which means the use of a plastic covering forming a double couple or the use of a plastic tunnel. The lowest coefficients for the use of radiant soil with tunnel and heat fan with double couple were respectively 7.19 W m-2 ºC-1 and 9.11 W m-2 ºC-1 and the largest value was 15.13 W m-2 ºC-1 for the heat fan use without plastics. Therefore, the results registered best thermal efficiency for the tested

  17. The numerical simulation of the WWER-440/V-213 reactor pressure vessel internals response to maximum hypothetical large break loss of coolant accident

    International Nuclear Information System (INIS)

    Hermansky, P.; Krajcovic, M.

    2012-01-01

    The reactor internals are designed to ensure cooling of the fuel, to ensure the movement of emergency control assemblies under all operating conditions including accidents and facilitate removal of the fuel and of the internals following an accident This paper presents results of the numerical simulation of the WWER-440/V213 reactor vessel internals dynamic response to maximum hypothetical Large-Break Loss of Coolant Accident. The purpose of this analysis is to determine the reactor vessel internals response due to rapid depressurization and to prove no such deformations occur in the reactor vessel internals which would prevent timely and proper activation of the emergency control assemblies. (Authors)

  18. Analysis of a hot-leg small break loss-of-coolant accident in a three-loop westinghouse pressurized water reactor plant

    International Nuclear Information System (INIS)

    Peterson, C.E.; Chexal, V.K.; Clements, T.B.

    1985-01-01

    The RETRAN-02 computer code was used to perform a best-estimate analysis of a 7.52-cm-diam hotleg break in a three-loop Westinghouse pressurized water reactor. This break size produced a net primary coolant mass depletion through the early portion of the transient. The primary system started to refill only after the accumulator valves opened. As the primary system refilled, there were extreme temperature differentials around the system with cold, denser fluid collecting at the lower elevations and two-phase fluid at higher elevations

  19. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  20. Net emission coefficient for CO–H2 thermal plasmas with the consideration of molecular systems

    International Nuclear Information System (INIS)

    Billoux, T.; Cressault, Y.; Gleizes, A.

    2015-01-01

    This paper deals with the calculation of net emission coefficients (NECs) for CO–H 2 thermal plasmas. This task required the elaboration of a complete spectroscopic database including atoms and molecules formed by carbon, oxygen and hydrogen elements. We have used a systematic line by line method to calculate all the main radiative contributions which are the atomic and molecular continua, the atomic lines and the molecular (diatomic and polyatomic) lines. The main diatomic electronic systems for CO–H 2 plasmas and the triatomic molecular bands were considered. We present some variations of the net emission coefficient versus temperature, for various pressures and for two relative proportions of the components. The role of the diatomic molecules is important at temperatures lower than 5000 K whereas the net emission coefficient presents an unusual peak at temperature around 1000 K, due to the presence of the CO 2 molecule presenting a strong infrared radiation. Finally, the results show that the NEC slightly depends on the relative proportion of CO and H 2 . - highlights: • We calculate radiative losses from CO–H 2 thermal plasmas. • We use the up-to-date atomic and molecular databases. • The influence of CO 2 molecule is very important at low temperature. • The relative maximum of the net emission coefficient at low temperature is unusual

  1. Cryogenic, Absolute, High Pressure Sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  2. Cryogenic High Pressure Sensor Module

    Science.gov (United States)

    Chapman, John J. (Inventor); Shams, Qamar A. (Inventor); Powers, William T. (Inventor)

    1999-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  3. Seven-Day Mortality Can Be Predicted in Medical Patients by Blood Pressure, Age, Respiratory Rate, Loss of Independence, and Peripheral Oxygen Saturation (the PARIS Score)

    DEFF Research Database (Denmark)

    Brabrand, Mikkel; Lassen, Annmarie Touborg; Knudsen, Torben

    2015-01-01

    university hospital and included all adult (≥15 years) patients. Multivariable logistic regression analysis was used to identify the clinical variables that best predicted the endpoint. From this, we developed a simplified model that can be calculated without specialized tools or loss of predictive ability......-day mortality of acutely admitted medical patients using routinely collected variables obtained within the first minutes after arrival. METHODS AND FINDINGS: This observational prospective cohort study used three independent cohorts at the medical admission units at a regional teaching hospital and a tertiary...... associated with the endpoint (full model). Based on this, we developed a simple score (range 0-5), ie, the PARIS score, by dichotomizing the variables. The ability to identify patients at increased risk (discriminatory power and calibration) was excellent for all three cohorts using both models. For patients...

  4. Quadrature formulas for Fourier coefficients

    KAUST Repository

    Bojanov, Borislav

    2009-09-01

    We consider quadrature formulas of high degree of precision for the computation of the Fourier coefficients in expansions of functions with respect to a system of orthogonal polynomials. In particular, we show the uniqueness of a multiple node formula for the Fourier-Tchebycheff coefficients given by Micchelli and Sharma and construct new Gaussian formulas for the Fourier coefficients of a function, based on the values of the function and its derivatives. © 2009 Elsevier B.V. All rights reserved.

  5. Coefficient Alpha: A Reliability Coefficient for the 21st Century?

    Science.gov (United States)

    Yang, Yanyun; Green, Samuel B.

    2011-01-01

    Coefficient alpha is almost universally applied to assess reliability of scales in psychology. We argue that researchers should consider alternatives to coefficient alpha. Our preference is for structural equation modeling (SEM) estimates of reliability because they are informative and allow for an empirical evaluation of the assumptions…

  6. Coefficient estimates of negative powers and inverse coefficients for ...

    Indian Academy of Sciences (India)

    and the inequality is sharp for the inverse of the Koebe function k(z) = z/(1 − z)2. An alternative approach to the inverse coefficient problem for functions in the class S has been investigated by Schaeffer and Spencer [27] and FitzGerald [6]. Although, the inverse coefficient problem for the class S has been completely solved ...

  7. Measuring of heat transfer coefficient

    DEFF Research Database (Denmark)

    Henningsen, Poul; Lindegren, Maria

    Subtask 3.4 Measuring of heat transfer coefficient Subtask 3.4.1 Design and setting up of tests to measure heat transfer coefficient Objective: Complementary testing methods together with the relevant experimental equipment are to be designed by the two partners involved in order to measure...... the heat transfer coefficient for a wide range of interface conditions in hot and warm forging processes. Subtask 3.4.2 Measurement of heat transfer coefficient The objective of subtask 3.4.2 is to determine heat transfer values for different interface conditions reflecting those typically operating in hot...

  8. Activity coefficient of aqueous sodium bicarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Pitzer, Kenneth S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Peiper, J. Christopher [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States)

    1980-09-01

    The determination of the activity coefficient and related properties of sodium bicarbonate presents special problems because of the appreciable vapor pressure of CO2 above such solutions. With the development of reliable equations for the thermodynamic properties of mixed electrolytes, it is possible to determine the parameters for NaHCO3 from cell measurements or NaCl-NaHCO3 mixtures. Literature data are analyzed to illustrate the method and provide interim values, hoever it is noted that further measurements over a wider range of concentrations would yield more definitive results. Lastly, an estimate is also given for the activity coefficient of KHCO3.

  9. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  10. Analysis of fuel rod behaviour within a rod bundle of a pressurized water reactor under the conditions of a loss of coolant accident (LOCA) using probabilistic methodology

    International Nuclear Information System (INIS)

    Sengpiel, W.

    1980-12-01

    The assessment of fuel rod behaviour under PWR LOCA conditions aims at the evaluation of the peak cladding temperatures and the (final) maximum circumferential cladding strains. Moreover, the estimation of the amount of possible coolant channel blockages within a rod bundle is of special interest, as large coplanar clad strains of adjacent rods may result in strong local reductions of coolant channel areas. Coolant channel blockages of large radial extent may impair the long-term coolability of the corresponding rods. A model has been developed to describe these accident consequences using probabilistic methodology. This model is applied to study the behaviour of fuel rods under accident conditions following the double-ended pipe rupture between collant pump and pressure vessel in the primary system of a 1300 MW(el)-PWR. Specifically a rod bundle is considered consisting of 236 fuel rods, that is subjected to severe thermal and mechanical loading. The results obtained indicate that plastic clad deformations with circumferential clad strains of more than 30% cannot be excluded for hot rods of the reference bundle. However, coplanar coolant channel blockages of significant extent seem to be probable within that bundle only under certain boundary conditions which are assumed to be pessimistic. (orig./RW) [de

  11. Heat transfer coefficient between UO2 and Zircaloy-2

    International Nuclear Information System (INIS)

    Ross, A.M.; Stoute, R.L.

    1962-06-01

    This paper provides some experimental values of the heat-transfer coefficient between UO 2 and Zircaloy-2 surfaces in contact under conditions of interfacial pressure, temperature, surface roughness and interface atmosphere, that are relevant to UO 2 /Zircaloy-2 fuel elements operating in pressurized-water power reactors. Coefficients were obtained from eight UO 2 / Zircaloy-2 pairs in atmospheres of helium, argon, krypton or xenon, at atmosphere pressure and in vacuum. Interfacial pressures were varied from 50 to 550 kgf/cm 2 while surface roughness heights were in the range 0.2 x 10 -4 to 3.5 x 10 -4 cm. The effect on the coefficients of cycling the interfacial pressure, of interface gas pressure and of temperature were examined. The experimental values of the coefficients were used to test the predictions of expressions for the heat-transfer between two solids in contact. For the particular UO 2 / Zircaloy-2 pairs examined, numerical values were assigned to several parameters that related the surface roughnesses to either the radius of solid/solid contact spots or to the mean thickness of the interface voids and that accounted for the imperfect accommodation of the void gas on the test surfaces. (author)

  12. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  13. Determination of Dimensionless Attenuation Coefficient in Shaped Resonators

    Science.gov (United States)

    Daniels, C.; Steinetz, B.; Finkbeiner, J.; Raman, G.; Li, X.

    2003-01-01

    The value of dimensionless attenuation coefficient is an important factor when numerically predicting high-amplitude acoustic waves in shaped resonators. Both the magnitude of the pressure waveform and the quality factor rely heavily on this dimensionless parameter. Previous authors have stated the values used, but have not completely explained their methods. This work fully describes the methodology used to determine this important parameter. Over a range of frequencies encompassing the fundamental resonance, the pressure waves were experimentally measured at each end of the shaped resonators. At the corresponding dimensionless acceleration, the numerical code modeled the acoustic waveforms generated in the resonator using various dimensionless attenuation coefficients. The dimensionless attenuation coefficient that most closely matched the pressure amplitudes and quality factors of the experimental and numerical results was determined to be the value to be used in subsequent studies.

  14. Unsteady aerodynamic coefficients obtained by a compressible vortex lattice method.

    OpenAIRE

    Fabiano Hernandes

    2009-01-01

    Unsteady solutions for the aerodynamic coefficients of a thin airfoil in compressible subsonic or supersonic flows are studied. The lift, the pitch moment, and pressure coefficients are obtained numerically for the following motions: the indicial response (unit step function) of the airfoil, i.e., a sudden change in the angle of attack; a thin airfoil penetrating into a sharp edge gust (for several gust speed ratios); a thin airfoil penetrating into a one-minus-cosine gust and sinusoidal gust...

  15. Uranium plasma emission coefficient in the visible and near UV.

    Science.gov (United States)

    Mack, J. M., Jr.; Usher, J. L.; Schneider, R. T.; Campbell, H. D.

    1971-01-01

    Measurements of the specific emission coefficient in the near ultra-violet and visible region of a uranium arc plasma are reported. Spatial unfolding of the intensity profile is used to determine the emission coefficient in the spectral range of 2000 A to 6000 A. The uranium partial pressure is estimated to range between .001 and .01 atmosphere, and the corresponding temperature range is 5000 - 10,000 K.

  16. Pressure Drop of Chamfer on Spacer Grid Strap

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Euijae; Kim, Kanghoon; Kim, Kyounghong; Nahm, Keeyil [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of)

    2014-05-15

    A swirl flow and cross flow are generated by the spacer grid with mixing vane that enhances the thermal performance and critical heat flux (CHF). The additional pressure drop makes it difficult to meet acceptance criteria for overall pressure drop in fuel assembly depending upon the pump capacity. The chamfer on the end of spacer grid strap is one solution to reduce additional pressure drop without any adverse effect on flow fields. In this research, the pressure drop tests for spacer grid with and without chamfer were carried out at the hydraulic test facility. The result can be applied to develop high performance nuclear fuel assemblies for Pressurized Water Reactor (PWR) plants. The pressure drop tests for 5x5 spacer grid with and without chamfer as well as 6x6 spacer grid with and without chamfer were carried out at the INFINIT test facility. The Reynolds number ranged about from 16000 to 75000. The sweep-up and sweep-down test showed that the direction of sweep did not affect the pressure drop. The chamfer on spacer grid strap reduced the pressure drop due to the decreased in ratio of inlet area to outlet area. The pressure loss coefficient for spacer grid with chamfer was by up to 13.8 % lower than that for spacer grid without chamfer. Hence, the chamfer on spacer grid strap was one of effective ways to reduce the pressure drop.

  17. Control-rod, pressure and flow-induced accident and transient analysis of a direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor

    International Nuclear Information System (INIS)

    Kitoh, Kazuaki; Koshizuka, Seiichi; Oka, Yoshiaki

    1996-01-01

    The features of the direct-cycle, supercritical-pressure, light-water-cooled fast breeder reactor (SCFBR) are high thermal efficiency and simple reactor system. The safety principle is basically the same as that of an LWR since it is a water-cooled reactor. Maintaining the core flow is the basic safety requirement of the reactor, since its coolant system is the one through type. The transient behaviors at control rod, pressure and flow-induced abnormalities are analyzed and presented in this paper. The results of flow-induced transients of SCFBR were reported at ICONE-3, though pressure change was neglected. The change of fuel temperature distribution is also considered for the analysis of the rapid reactivity-induced transients such as control rod withdrawal. Total loss of flow and pump seizure are analyzed as the accidents. Loss of load, control rod withdrawal from the normal operation, loss of feedwater heating, inadvertent start of an auxiliary feedwater pump, partial loss of coolant flow and loss of external power are analyzed as the transients. The behavior of the flow-induced transients is not so much different from the analyses assuming constant pressure. Fly wheels should be equipped with the feedwater pumps to prolong the coast-down time more than 10s and to cope with the total loss of flow accident. The coolant density coefficient of the SCFBR is less than one tenth of a BWR in which the recirculation flow is used for the power control. The over pressurization transients at the loss of load is not so severe as that of a BWR. The power reaches 120%. The minimum deterioration heat flux ratio (MDHFR) and the maximum pressure are sufficiently lower than the criteria; MDHFR above 1.0 and pressure ratio below 1.10 of 27.5 MPa, maximum pressure for operation. Among the reactivity abnormalities, the control rod withdrawal transient from the normal operation is analyzed

  18. Stability analysis of supercritical-pressure light water-cooled reactor in constant pressure operation

    International Nuclear Information System (INIS)

    Suhwan, JI; Shirahama, H.; Koshizuka, S.; Oka, Y.

    2001-01-01

    The purpose of this study is to evaluate the thermal-hydraulic and the thermal-nuclear coupled stabilities of a supercritical pressure light water-cooled reactor. A stability analysis code at supercritical pressure is developed. Using this code, stabilities of full and partial-power reactor operating at supercritical pressure are investigated by the frequency-domain analysis. Two types of SCRs are analyzed; a supercritical light water reactor (SCLWR) and a supercritical water-cooled fast reactor (SCFR). The same stability criteria as Boiling Water Reactor are applied. The thermal-hydraulic stability of SCLWR and SCFR satisfies the criteria with a reasonable orifice loss coefficient. The decay ratio of the thermal-nuclear coupled stability in SCFR is almost zero because of a small coolant density coefficient of the fast reactor. The evaluated decay ratio of the thermal-nuclear coupled stability is 3,41 ∼ 10 -V at 100% power in SCFR and 0,028 at 100% power in SCLWR. The sensitivity is investigated. It is found that the thermal-hydraulic stability is sensitive to the mass flow rate strongly and the thermal-nuclear coupled stability to the coolant density coefficient. The bottom power peak distribution makes the thermal-nuclear stability worse and the thermal-nuclear stability better. (author)

  19. Probabilistic optimization of safety coefficients

    International Nuclear Information System (INIS)

    Marques, M.; Devictor, N.; Magistris, F. de

    1999-01-01

    This article describes a reliability-based method for the optimization of safety coefficients defined and used in design codes. The purpose of the optimization is to determine the partial safety coefficients which minimize an objective function for sets of components and loading situations covered by a design rule. This objective function is a sum of distances between the reliability of the components designed using the safety coefficients and a target reliability. The advantage of this method is shown on the examples of the reactor vessel, a vapour pipe and the safety injection circuit. (authors)

  20. Cutaneous water loss and sphingolipids in the stratum corneum of house sparrows, Passer domesticus L., from desert and mesic environments as determined by reversed phase high-performance liquid chromatography coupled with atmospheric pressure photospray ionization mass spectrometry.

    Science.gov (United States)

    Muñoz-Garcia, Agustí; Ro, Jennifer; Brown, Johnie C; Williams, Joseph B

    2008-02-01

    Because cutaneous water loss (CWL) represents half of total water loss in birds, selection to reduce CWL may be strong in desert birds. We previously found that CWL of house sparrows from a desert population was about 25% lower than that of individuals from a mesic environment. The stratum corneum (SC), the outer layer of the epidermis, serves as the primary barrier to water vapor diffusion through the skin. The avian SC is formed by layers of corneocytes embedded in a lipid matrix consisting of cholesterol, free fatty acids and two classes of sphingolipids, ceramides and cerebrosides. The SC of birds also serves a thermoregulatory function; high rates of CWL keep body temperatures under lethal limits in episodes of heat stress. In this study, we used high-performance liquid chromatography coupled with atmospheric pressure photoionization-mass spectrometry (HPLC/APPI-MS) to identify and quantify over 200 sphingolipids in the SC of house sparrows from desert and mesic populations. Principal components analysis (PCA) led to the hypotheses that sphingolipids in the SC of desert sparrows have longer carbon chains in the fatty acid moiety and are more polar than those found in mesic sparrows. We also tested the association between principal components and CWL in both populations. Our study suggested that a reduction in CWL found in desert sparrows was, in part, the result of modifications in chain length and polarity of the sphingolipids, changes that apparently determine the interactions of the lipid molecules within the SC.

  1. Calculation of self-diffusion coefficients in iron

    Directory of Open Access Journals (Sweden)

    Baohua Zhang

    2014-01-01

    Full Text Available On the basis of available P-V-T equation of state of iron, the temperature and pressure dependence of self-diffusion coefficients in iron polymorphs (α, δ, γ and ɛ phases have been successfully reproduced in terms of the bulk elastic and expansivity data by means of a thermodynamical model that interconnects point defects parameters with bulk properties. The calculated diffusion parameters, such as self-diffusion coefficient, activation energy and activation volume over a broad temperature range (500-2500 K and pressure range (0-100 GPa, compare favorably well with experimental or theoretical ones when the uncertainties are considered.

  2. Quadrature formulas for Fourier coefficients

    KAUST Repository

    Bojanov, Borislav; Petrova, Guergana

    2009-01-01

    We consider quadrature formulas of high degree of precision for the computation of the Fourier coefficients in expansions of functions with respect to a system of orthogonal polynomials. In particular, we show the uniqueness of a multiple node

  3. Diffusion coefficient for anomalous transport

    International Nuclear Information System (INIS)

    1986-01-01

    A report on the progress towards the goal of estimating the diffusion coefficient for anomalous transport is given. The gyrokinetic theory is used to identify different time and length scale inherent to the characteristics of plasmas which exhibit anomalous transport

  4. Influence of various base oils on friction and power loss in gears; Einfluss verschiedener Grundoele auf Reibung und Verlustleistung in Zahnradgetrieben

    Energy Technology Data Exchange (ETDEWEB)

    Doleschel, A.; Michaelis, K.; Hoehn, B.R.

    2001-03-01

    The frictional behaviour of synthetic lubricants was systematically investigated in a twin disc test rig and a back-to-back gear test rig. For 22 lubricants (mineral oil, polyalfaolefin (PAO), polyglycol (PG), ester and mixtures) the coefficient of friction was measured in the twin disc test rig, dependant on pressure, oil temperature, rolling and sliding velocity. In the gear test rig pressure and velocity was varied for 9 lubricants. The mineral oil shows an estimated coefficient of friction of about {mu} >> 0.045, the synthetic lubricants have a lower coefficient of friction. In the twin disc test rig the lowest coefficient of friction with PG as low as 20% of the coefficient of mineral oil was measured, depending on the mixture of EO:PO. In the gear test rig such low coefficients of friction were not measured, but still values of 60% compared to mineral oil were obtained. Esters show in the twin disc test rig a coefficient of friction in the range of 30% to 100% of the coefficient of friction of mineral oil, in the gear test rig in the range of 60% to 100%. From these investigations a calculation method for the coefficient of friction in disc and gear contacts was derived. With these equations the power loss and efficiency of transmissions in practice, lubricated with synthetic gear oils can be evaluated. (orig.)

  5. Fuel Temperature Coefficient of Reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Loewe, W.E.

    2001-07-31

    A method for measuring the fuel temperature coefficient of reactivity in a heterogeneous nuclear reactor is presented. The method, which is used during normal operation, requires that calibrated control rods be oscillated in a special way at a high reactor power level. The value of the fuel temperature coefficient of reactivity is found from the measured flux responses to these oscillations. Application of the method in a Savannah River reactor charged with natural uranium is discussed.

  6. Properties of Traffic Risk Coefficient

    Science.gov (United States)

    Tang, Tie-Qiao; Huang, Hai-Jun; Shang, Hua-Yan; Xue, Yu

    2009-10-01

    We use the model with the consideration of the traffic interruption probability (Physica A 387(2008)6845) to study the relationship between the traffic risk coefficient and the traffic interruption probability. The analytical and numerical results show that the traffic interruption probability will reduce the traffic risk coefficient and that the reduction is related to the density, which shows that this model can improve traffic security.

  7. Experiencing Loss

    DEFF Research Database (Denmark)

    Kristiansen, Maria; Younis, Tarek; Hassani, Amani

    2015-01-01

    In this article, we explore how Islam, minority status and refugee experiencesintersect in shaping meaning-making processes following bereavement. We do this througha phenomenological analysis of a biographical account of personal loss told by Aisha, a Muslim Palestinian refugee living in Denmark......, who narrates her experience of losing herhusband to lung cancer. By drawing on a religious framework, Aisha creates meaning fromher loss, which enables her to incorporate this loss into her life history and sustain agency.Her narrative invites wider audiences to witness her tale of overcoming loss...

  8. Environmental coefficients of the free-field sensitivity of measurement microphones

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Cutanda Henriquez, Vicente; Torras-Rosell, Antoni

    2017-01-01

    The sensitivity of measurement microphones, both pressure and free field, is affected by changes in the environmental conditions, mainly temperature and static pressure. Static pressure and temperature coefficients for the pressure sensitivity have been the object of previous studies focused...... on Laboratory Standard microphones and few working standard microphones. The literature describes frequency dependent values for these coefficients which are used for calibration purposes. However, there is no description of the environmental coefficients of the free-field sensitivity though there have been...... some implementations that attempt to take care of the differences between the coefficients for the two types of sensitivities. Measuring the coefficients in a free field poses some challeng; it is not so easy to change neither the static pressure nor the temperature inside anechoic room within...

  9. Thermal conductivity coefficients of water and heavy water in the liquid state up to 3700C

    International Nuclear Information System (INIS)

    Le Neindre, B.; Bury, P.; Tufeu, R.; Vodar, B.

    1976-01-01

    The thermal conductivity coefficients of water and heavy water of 99.75 percent isotopic purity were measured using a coaxial cylinder apparatus, covering room temperature to their critical temperatures, and pressures from 1 to 500 bar for water, and from 1 to 1000 bar for heavy water. Following the behavior of the thermal conductivity coefficient of water, which shows a maximum close to 135 0 C, the thermal conductivity coefficient of heavy water exhibits a maximum near 95 0 C and near saturation pressures. This maximum is displaced to higher temperatures when the pressure is increased. Under the same temperature and pressure conditions the thermal conductivity coefficient of heavy water was lower than for water. The pressure effect was similar for water and heavy water. In the temperature range of our experiments, isotherms of thermal conductivity coefficients were almost linear functions of density

  10. Temperature-Dependent Rate Coefficients for the Reaction of CH2OO with Hydrogen Sulfide.

    Science.gov (United States)

    Smith, Mica C; Chao, Wen; Kumar, Manoj; Francisco, Joseph S; Takahashi, Kaito; Lin, Jim Jr-Min

    2017-02-09

    The reaction of the simplest Criegee intermediate CH 2 OO with hydrogen sulfide was measured with transient UV absorption spectroscopy in a temperature-controlled flow reactor, and bimolecular rate coefficients were obtained from 278 to 318 K and from 100 to 500 Torr. The average rate coefficient at 298 K and 100 Torr was (1.7 ± 0.2) × 10 -13 cm 3 s -1 . The reaction was found to be independent of pressure and exhibited a weak negative temperature dependence. Ab initio quantum chemistry calculations of the temperature-dependent reaction rate coefficient at the QCISD(T)/CBS level are in reasonable agreement with the experiment. The reaction of CH 2 OO with H 2 S is 2-3 orders of magnitude faster than the reaction with H 2 O monomer. Though rates of CH 2 OO scavenging by water vapor under atmospheric conditions are primarily controlled by the reaction with water dimer, the H 2 S loss pathway will be dominated by the reaction with monomer. The agreement between experiment and theory for the CH 2 OO + H 2 S reaction lends credence to theoretical descriptions of other Criegee intermediate reactions that cannot easily be probed experimentally.

  11. Clustering Coefficients for Correlation Networks.

    Science.gov (United States)

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly

  12. Clustering Coefficients for Correlation Networks

    Directory of Open Access Journals (Sweden)

    Naoki Masuda

    2018-03-01

    Full Text Available Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients

  13. Clustering Coefficients for Correlation Networks

    Science.gov (United States)

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly

  14. Nondestructive hall coefficient measurements using ACPD techniques

    Science.gov (United States)

    Velicheti, Dheeraj; Nagy, Peter B.; Hassan, Waled

    2018-04-01

    Hall coefficient measurements offer great opportunities as well as major challenges for nondestructive materials characterization. The Hall effect is produced by the magnetic Lorentz force acting on moving charge carriers in the presence of an applied magnetic field. The magnetic perturbation gives rise to a Hall current that is normal to the conduction current but does not directly perturb the electric potential distribution. Therefore, Hall coefficient measurements usually exploit the so-called transverse galvanomagnetic potential drop effect that arises when the Hall current is intercepted by the boundaries of the specimen and thereby produce a measurable potential drop. In contrast, no Hall potential is produced in a large plate in the presence of a uniform normal field at quasi-static low frequencies. In other words, conventional Hall coefficient measurements are inherently destructive since they require cutting the material under tests. This study investigated the feasibility of using alternating current potential drop (ACPD) techniques for nondestructive Hall coefficient measurements in plates. Specifically, the directional four-point square-electrode configuration is investigated with superimposed external magnetic field. Two methods are suggested to make Hall coefficient measurements in large plates without destructive machining. At low frequencies, constraining the bias magnetic field can replace constraining the dimensions of the specimen, which is inherently destructive. For example, when a cylindrical permanent magnet is used to provide the bias magnetic field, the peak Hall voltage is produced when the diameter of the magnet is equal to the diagonal of the square ACPD probe. Although this method is less effective than cutting the specimen to a finite size, the loss of sensitivity is less than one order of magnitude even at very low frequencies. In contrast, at sufficiently high inspection frequencies the magnetic field of the Hall current induces a

  15. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  16. Memory loss

    Science.gov (United States)

    ... barbiturates or ( hypnotics ) ECT (electroconvulsive therapy) (most often short-term memory loss) Epilepsy that is not well controlled Illness that ... appointment. Medical history questions may include: Type of memory loss, such as short-term or long-term Time pattern, such as how ...

  17. Experimental study of the heat transfer and of pressure losses with gaseous hydrogen in turbulent flow in a tube and in an annular space; Etude experimentale du transfert de chaleur et des pertes de charge avec l'hydrogene gazeux en ecoulement turbulent dans un tube et dans un espace annulaire

    Energy Technology Data Exchange (ETDEWEB)

    La Harpe, A de; Perroud, P [Commissariat a l' Energie Atomique, Grenoble (France).Centre d' Etudes Nucleaires

    1961-07-01

    Three different dispositions were used: a tube (diameter 4 mm, length 320 mm) and two annular spaces (3 x 8.8 and 5 x 8.8 mm, length 260 mm). The tubes are of stainless steel and are heated by a 50 cycle alternating current. The Reynolds number varied from 4000 to 120000, the wall temperature up to 700 deg. C, and the exit-temperature up to 500 deg. C. Heat flows of up to 170 W/cm{sup 2} were observed. All the experimental results can be summed up by a correlation expression of the Colburn type Nu = 0,020 Re{sup 0.8} Pr{sup 0.4}, as long as the physical properties of the gas are expressed at the film temperature t{sub 0.3} = t{sub m} + 0.3 (t{sub p} - t{sub m}). For each particular disposition, a more exact correlation has however been obtained. A variation of the film temperature index with the ratio of the heated to the wetted perimeters has been observed. The pressure loss coefficients measured are lightly higher than those calculated using von Karman formula for smooth tubes. (author) [French] On a utilise trois geometries differentes: tube (diametre 4 mm, longueur 320 mm) et deux espaces annulaires (3 x 8,8 et 5 x 8,8 mm, longueur 260 mm). Les tubes sont en acier inoxydable et chauffes en courant alternatif 50 Hz. Le nombre de Reynolds a varie de 4000 a 120000, la temperature de paroi jusqu'a 700 deg. C et la temperature de sortie de l'hydrogene jusqu'a 500 deg. C. On a observe des flux de chaleur atteignant 170 W/cm{sup 2}. L'ensemble des resultats experimentaux peut etre resume par la formule de correlation, type Colburn, Nu = 0,020 Re{sup 0,8} Pr{sup 0,4} a condition d'evaluer les proprietes physiques du gaz a la temperature de film t{sub 0.3} = t{sub m} + 0.3 (t{sub p} - t{sub m}). Pour chaque geometrie particuliere, une correlation plus precise a cependant pu etre obtenue. On note une variation de l'indice de la temperature de film avec le rapport du perimetre chauffant au perimetre mouille. Les coefficients de perte de charge mesures sont legerement plus

  18. Amide temperature coefficients in the protein G B1 domain

    International Nuclear Information System (INIS)

    Tomlinson, Jennifer H.; Williamson, Mike P.

    2012-01-01

    Temperature coefficients have been measured for backbone amide 1 H and 15 N nuclei in the B1 domain of protein G (GB1), using temperatures in the range 283–313 K, and pH values from 2.0 to 9.0. Many nuclei display pH-dependent coefficients, which were fitted to one or two pK a values. 1 H coefficients showed the expected behaviour, in that hydrogen-bonded amides have less negative values, but for those amides involved in strong hydrogen bonds in regular secondary structure there is a negative correlation between strength of hydrogen bond and size of temperature coefficient. The best correlation to temperature coefficient is with secondary shift, indicative of a very approximately uniform thermal expansion. The largest pH-dependent changes in coefficient are for amides in loops adjacent to sidechain hydrogen bonds rather than the amides involved directly in hydrogen bonds, indicating that the biggest determinant of the temperature coefficient is temperature-dependent loss of structure, not hydrogen bonding. Amide 15 N coefficients have no clear relationship with structure.

  19. Effect of Variable Manning Coefficients on Tsunami Inundation

    Science.gov (United States)

    Barberopoulou, A.; Rees, D.

    2017-12-01

    Numerical simulations are commonly used to help estimate tsunami hazard, improve evacuation plans, issue or cancel tsunami warnings, inform forecasting and hazard assessments and have therefore become an integral part of hazard mitigation among the tsunami community. Many numerical codes exist for simulating tsunamis, most of which have undergone extensive benchmarking and testing. Tsunami hazard or risk assessments employ these codes following a deterministic or probabilistic approach. Depending on the scope these studies may or may not consider uncertainty in the numerical simulations, the effects of tides, variable friction or estimate financial losses, none of which are necessarily trivial. Distributed manning coefficients, the roughness coefficients used in hydraulic modeling, are commonly used in simulating both riverine and pluvial flood events however, their use in tsunami hazard assessments is primarily part of limited scope studies and for the most part, not a standard practice. For this work, we investigate variations in manning coefficients and their effects on tsunami inundation extent, pattern and financial loss. To assign manning coefficients we use land use maps that come from the New Zealand Land Cover Database (LCDB) and more recent data from the Ministry of the Environment. More than 40 classes covering different types of land use are combined into major classes such as cropland, grassland and wetland representing common types of land use in New Zealand, each of which is assigned a unique manning coefficient. By utilizing different data sources for variable manning coefficients, we examine the impact of data sources and classification methodology on the accuracy of model outputs.

  20. Analysis of internal conversion coefficients

    International Nuclear Information System (INIS)

    Coursol, N.; Gorozhankin, V.M.; Yakushev, E.A.; Briancon, C.; Vylov, Ts.

    2000-01-01

    An extensive database has been assembled that contains the three most widely used sets of calculated internal conversion coefficients (ICC): [Hager R.S., Seltzer E.C., 1968. Internal conversion tables. K-, L-, M-shell Conversion coefficients for Z=30 to Z=103, Nucl. Data Tables A4, 1-237; Band I.M., Trzhaskovskaya M.B., 1978. Tables of gamma-ray internal conversion coefficients for the K-, L- and M-shells, 10≤Z≤104, Special Report of Leningrad Nuclear Physics Institute; Roesel F., Fries H.M., Alder K., Pauli H.C., 1978. Internal conversion coefficients for all atomic shells, At. Data Nucl. Data Tables 21, 91-289] and also includes new Dirac-Fock calculations [Band I.M. and Trzhaskovskaya M.B., 1993. Internal conversion coefficients for low-energy nuclear transitions, At. Data Nucl. Data Tables 55, 43-61]. This database is linked to a computer program to plot ICCs and their combinations (sums and ratios) as a function of Z and energy, as well as relative deviations of ICC or their combinations for any pair of tabulated data. Examples of these analyses are presented for the K-shell and total ICCs of the gamma-ray standards [Hansen H.H., 1985. Evaluation of K-shell and total internal conversion coefficients for some selected nuclear transitions, Eur. Appl. Res. Rept. Nucl. Sci. Tech. 11.6 (4) 777-816] and for the K-shell and total ICCs of high multipolarity transitions (total, K-, L-, M-shells of E3 and M3 and K-shell of M4). Experimental data sets are also compared with the theoretical values of these specific calculations

  1. Investigation of Wear Coefficient of Manganese Phosphate Coated Tool Steel

    Directory of Open Access Journals (Sweden)

    S. Ilaiyavel

    2013-03-01

    Full Text Available In recent years the properties of the coating in terms of wear resistance is of paramount importance in order to prevent the formation of severe damages. In this study, Wear coefficient of uncoated, Manganese Phosphate coated, Manganese Phosphate coated with oil lubricant, Heat treated Manganese Phosphate coated with oil lubricant on AISI D2 steels was investigated using Archard’s equation. The wear tests were performed in a pin on disk apparatus as per ASTM G-99 Standard. The volumetric wear loss and wear coefficient were evaluated through pin on disc test using a sliding velocity of 3.0 m/s under normal load of 40 N and controlled condition of temperature and humidity. Based on the results of the wear test, the Heat treated Manganese Phosphate with oil lubricant exhibited the lowest average wear coefficient and the lowest wear loss under 40 N load.

  2. Seven-day mortality can be predicted in medical patients by blood pressure, age, respiratory rate, loss of independence, and peripheral oxygen saturation (the PARIS score: a prospective cohort study with external validation.

    Directory of Open Access Journals (Sweden)

    Mikkel Brabrand

    Full Text Available Most existing risk stratification systems predicting mortality in emergency departments or admission units are complex in clinical use or have not been validated to a level where use is considered appropriate. We aimed to develop and validate a simple system that predicts seven-day mortality of acutely admitted medical patients using routinely collected variables obtained within the first minutes after arrival.This observational prospective cohort study used three independent cohorts at the medical admission units at a regional teaching hospital and a tertiary university hospital and included all adult (≥ 15 years patients. Multivariable logistic regression analysis was used to identify the clinical variables that best predicted the endpoint. From this, we developed a simplified model that can be calculated without specialized tools or loss of predictive ability. The outcome was defined as seven-day all-cause mortality. 76 patients (2.5% met the endpoint in the development cohort, 57 (2.0% in the first validation cohort, and 111 (4.3% in the second. Systolic blood Pressure, Age, Respiratory rate, loss of Independence, and peripheral oxygen Saturation were associated with the endpoint (full model. Based on this, we developed a simple score (range 0-5, ie, the PARIS score, by dichotomizing the variables. The ability to identify patients at increased risk (discriminatory power and calibration was excellent for all three cohorts using both models. For patients with a PARIS score ≥ 3, sensitivity was 62.5-74.0%, specificity 85.9-91.1%, positive predictive value 11.2-17.5%, and negative predictive value 98.3-99.3%. Patients with a score ≤ 1 had a low mortality (≤ 1%; with 2, intermediate mortality (2-5%; and ≥ 3, high mortality (≥ 10%.Seven-day mortality can be predicted upon admission with high sensitivity and specificity and excellent negative predictive values.

  3. Algebraic polynomials with random coefficients

    Directory of Open Access Journals (Sweden)

    K. Farahmand

    2002-01-01

    Full Text Available This paper provides an asymptotic value for the mathematical expected number of points of inflections of a random polynomial of the form a0(ω+a1(ω(n11/2x+a2(ω(n21/2x2+…an(ω(nn1/2xn when n is large. The coefficients {aj(w}j=0n, w∈Ω are assumed to be a sequence of independent normally distributed random variables with means zero and variance one, each defined on a fixed probability space (A,Ω,Pr. A special case of dependent coefficients is also studied.

  4. Methodology to predict friction pressure drop in drilling fluid flows; Metodologia para previsao de perdas de carga em escoamentos de fluidos de perfuracao

    Energy Technology Data Exchange (ETDEWEB)

    Scheid, Claudia Miriam; Calcada, Luis Americo [Universidade Federal Rural do Rio de Janeiro (UFRRJ). Departamento de Engenharia Quimica (Brazil)], e-mails: scheid@ufrrj.br, calcada@ufrrj.br; Rocha, Daniele Cristine [Centro de Pesquisas da Petrobras (CENPES). Engenharia Basica de Abastecimento - Gas e Energia (Brazil)], e-mail: drocha@petrobras.com.br; Aranha, Pedro Esteves [Centro de Pesquisas da Petrobras (CENPES). Gerencia de Perfuracao e Completacao de Pocos (Brazil)], e-mail: pearanha@petrobras.com.br; Aragao, Atila Fernando Lima [E and P Construcao de Pocos Maritimos. Gerencia de Tecnologia de Fluidos (Brazil)], e-mail: atila_aragao@petrobras.com.br

    2009-12-15

    An extensive experimental study is detailed to evaluate the friction pressure drop resulting from the flow through pipe and annular sections, accessories such as tool joints, bit jets and stabilizers of four different drilling fluids used in deep water operations. After a data analysis process, it was possible to compile a set of equations to predict relevant hydraulic friction pressure loss calculations, such as: hydraulic diameter for annular flows, friction factors for pipe and annular turbulent flows and discharge coefficients for accessories. (author)

  5. Condensing heat transfer following a loss-of-coolant accident

    International Nuclear Information System (INIS)

    Krotiuk, W.J.; Rubin, M.B.

    1978-01-01

    A new method for calculating the steam mass condensation energy removal rates on cold surfaces in contact with an air-steam mixture has been developed. This method is based on the principles of mass diffusion of steam from an area of high concentration to the condensing surface, which is an area of low steam concentration. This new method of calculating mass condensation has been programmed into the CONTEMPT-LT Mod 26 computer code, which calculates the pressure and temperature transients inside a light water reactor containment following a loss-of-coolant accident. The condensing heat transfer coefficient predicted by the mass diffusion method is compared to existing semi-empirical correlations and to the experimental results of the Carolinas Virginia Tube Reactor Containment natural decay test. Closer agreement with test results is shown in the calculation of containment pressure, temperature, and heat sink surface temperature using the mass diffusion condensation method than when using any existing semi-empirical correlation

  6. Weight Loss

    Science.gov (United States)

    ... Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home Food MyFoodAdvisor ... Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In My Community Home ...

  7. Irrational "Coefficients" in Renaissance Algebra.

    Science.gov (United States)

    Oaks, Jeffrey A

    2017-06-01

    Argument From the time of al-Khwārizmī in the ninth century to the beginning of the sixteenth century algebraists did not allow irrational numbers to serve as coefficients. To multiply by x, for instance, the result was expressed as the rhetorical equivalent of . The reason for this practice has to do with the premodern concept of a monomial. The coefficient, or "number," of a term was thought of as how many of that term are present, and not as the scalar multiple that we work with today. Then, in sixteenth-century Europe, a few algebraists began to allow for irrational coefficients in their notation. Christoff Rudolff (1525) was the first to admit them in special cases, and subsequently they appear more liberally in Cardano (1539), Scheubel (1550), Bombelli (1572), and others, though most algebraists continued to ban them. We survey this development by examining the texts that show irrational coefficients and those that argue against them. We show that the debate took place entirely in the conceptual context of premodern, "cossic" algebra, and persisted in the sixteenth century independent of the development of the new algebra of Viète, Decartes, and Fermat. This was a formal innovation violating prevailing concepts that we propose could only be introduced because of the growing autonomy of notation from rhetorical text.

  8. Integer Solutions of Binomial Coefficients

    Science.gov (United States)

    Gilbertson, Nicholas J.

    2016-01-01

    A good formula is like a good story, rich in description, powerful in communication, and eye-opening to readers. The formula presented in this article for determining the coefficients of the binomial expansion of (x + y)n is one such "good read." The beauty of this formula is in its simplicity--both describing a quantitative situation…

  9. Perda auditiva induzida por ruído e hipertensão em condutores de ônibus Noise-induced hearing loss and high blood pressure among city bus drivers

    Directory of Open Access Journals (Sweden)

    Heleno Rodrigues Corrêa Filho

    2002-12-01

    Full Text Available OBJETIVO: Estimar as prevalências de perda auditiva induzida por ruído e hipertensão arterial em condutores de ônibus urbanos. MÉTODOS: Executou-se estudo transversal em amostra probabilística de 108 motoristas da cidade de Campinas, SP. Aplicou-se questionário sobre história profissional, jornadas de trabalho e repouso, e realizou-se exame físico e laboratorial incluindo medida da pressão arterial, audiometria tonal limiar, logoaudiometria e dados antropométricos, após a obtenção de consentimento. RESULTADOS: A prevalência de perda auditiva induzida por ruído foi de 32,7% do total examinado. Segundo a classificação de Merluzzi, nos 31 casos classificados em primeiro e segundo graus, observou-se que a freqüência audiométrica com perda auditiva mais acentuada foi a de 6 kHz (61,3%, seguida pela de 4 kHz (38,7%, sem diferenças significantes quanto à lateralidade. A prevalência de hipertensão arterial diastólica (PAD³90 mmHG; PAS³140 mmHG foi de 13,2% dos examinados. CONCLUSÕES: O risco de disacusia induzida por ruído foi maior para os motoristas com mais de seis anos de trabalho, após ajuste para a perda relacionada com a idade, com um odds ratio de 19,25 (1,59OBJECTIVE: To estimate the prevalence of occupational noise-induced hearing loss and arterial hypertension among city bus drivers. METHODS: A cross-sectional study was carried out on a probability random sample of 108 city bus drivers taken out of a total of 1,529 estimated professionals in the city of Campinas, Brazil, in 1991. Drivers were interviewed using questionnaires on job history, shift work and vacation schedules and underwent clinical and laboratory examinations including measures of blood pressure, pure-tone audiometry, speech audiometry, and anthropometric data analysis after an informed consent was obtained. RESULTS: The prevalence of noise-induced hearing loss was 32.7%. According to Merluzzi's classification, 91.2% (31 cases were classified as

  10. A technique for measuring dynamic friction coefficient under impact loading.

    Science.gov (United States)

    Lin, Y L; Qin, J G; Chen, R; Zhao, P D; Lu, F Y

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m(2)/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  11. Activity coefficients from molecular simulations using the OPAS method

    Science.gov (United States)

    Kohns, Maximilian; Horsch, Martin; Hasse, Hans

    2017-10-01

    A method for determining activity coefficients by molecular dynamics simulations is presented. It is an extension of the OPAS (osmotic pressure for the activity of the solvent) method in previous work for studying the solvent activity in electrolyte solutions. That method is extended here to study activities of all components in mixtures of molecular species. As an example, activity coefficients in liquid mixtures of water and methanol are calculated for 298.15 K and 323.15 K at 1 bar using molecular models from the literature. These dense and strongly interacting mixtures pose a significant challenge to existing methods for determining activity coefficients by molecular simulation. It is shown that the new method yields accurate results for the activity coefficients which are in agreement with results obtained with a thermodynamic integration technique. As the partial molar volumes are needed in the proposed method, the molar excess volume of the system water + methanol is also investigated.

  12. Effect of applied mechanical stress on absorption coefficient of compounds

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Manoj Kumar, E-mail: mkgupta.sliet@gmail.com [Department of Applied Sciences, Bhai Gurdas Institute of Engineering and Technology, Sangrur (India); Singh, Gurinderjeet; Dhaliwal, A. S.; Kahlon, K. S. [Department of Physics, Sant Longowal Institute of Engineering & Technology Deemed University, Longowal (Sangrur) India-148106 (India)

    2015-08-28

    The absorption coefficient of given materials is the parameter required for the basic information. The measurement of absorption coefficient of compounds Al{sub 2}O{sub 3}, CaCO{sub 3}, ZnO{sub 2}, SmO{sub 2} and PbO has been taken at different incident photon energies 26, 59.54, 112, 1173, 1332keV. The studies involve the measurements of absorption coefficient of the self supporting samples prepared under different mechanical stress. This mechanical stress is render in terms of pressure up to 0-6 ton by using hydraulic press. Measurements shows that absorption coefficient of a material is directly proportional to applied mechanical stress on it up to some extent then become independent. Experimentally measured results are in fairly good agreement with in theoretical values obtained from WinXCOM.

  13. Pressure drop and heat transfer of lithium single-phase flow under transverse magnetic field

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Aritomi, Masanori; Inoue, Akira; Matsuzaki, Mitsuo

    1996-01-01

    Pressure drop and heat transfer characteristics of a lithium single-phase flow in a rectangular channel was investigated experimentally in the presence of a magnetic field. Friction loss coefficient under non-magnetic field and skin friction coefficient under magnetic field agreed well with the Blasius formula and a simple analytical expression, respectively. Nusselt number under non-magnetic field was slightly lower than the correlation by Hartnett and Irvine. Heat transfer was enhanced by increasing magnetic field above the Hartmann number of about 200. (author)

  14. Shear viscosity coefficient from microscopic models

    International Nuclear Information System (INIS)

    Muronga, Azwinndini

    2004-01-01

    The transport coefficient of shear viscosity is studied for a hadron matter through microscopic transport model, the ultrarelativistic quantum molecular dynamics (UrQMD), using the Green-Kubo formulas. Molecular-dynamical simulations are performed for a system of light mesons in a box with periodic boundary conditions. Starting from an initial state composed of π,η,ω,ρ,φ with a uniform phase-space distribution, the evolution takes place through elastic collisions, production, and annihilation. The system approaches a stationary state of mesons and their resonances, which is characterized by common temperature. After equilibration, thermodynamic quantities such as the energy density, particle density, and pressure are calculated. From such an equilibrated state the shear viscosity coefficient is calculated from the fluctuations of stress tensor around equilibrium using Green-Kubo relations. We do our simulations here at zero net baryon density so that the equilibration times depend on the energy density. We do not include hadron strings as degrees of freedom so as to maintain detailed balance. Hence we do not get the saturation of temperature but this leads to longer equilibration times

  15. Hidden loss

    DEFF Research Database (Denmark)

    Kieffer-Kristensen, Rikke; Johansen, Karen Lise Gaardsvig

    2013-01-01

    to participate. RESULTS: All children were affected by their parents' ABI and the altered family situation. The children's expressions led the authors to identify six themes, including fear of losing the parent, distress and estrangement, chores and responsibilities, hidden loss, coping and support. The main......PRIMARY OBJECTIVE: The purpose of this study was to listen to and learn from children showing high levels of post-traumatic stress symptoms after parental acquired brain injury (ABI), in order to achieve an in-depth understanding of the difficulties the children face in their everyday lives...... finding indicates that the children experienced numerous losses, many of which were often suppressed or neglected by the children to protect the ill parents. CONCLUSIONS: The findings indicated that the children seemed to make a special effort to hide their feelings of loss and grief in order to protect...

  16. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  17. Extinction Coefficient of Gold Nanostars

    OpenAIRE

    de Puig, Helena; Tam, Justina O.; Yen, Chun-Wan; Gehrke, Lee; Hamad-Schifferli, Kimberly

    2015-01-01

    Gold nanostars (NStars) are highly attractive for biological applications due to their surface chemistry, facile synthesis and optical properties. Here, we synthesize NStars in HEPES buffer at different HEPES/Au ratios, producing NStars of different sizes and shapes, and therefore varying optical properties. We measure the extinction coefficient of the synthesized NStars at their maximum surface plasmon resonances (SPR), which range from 5.7 × 108 to 26.8 × 108 M−1cm−1. Measured values correl...

  18. 二氧化碳与2-丁醇二元体系在高压下的亨利系数和偏摩尔体积性质计算%Calculation of Henry's coefficient and partial molar volume of carbon dioxide in 2-butanol at elevated pressures

    Institute of Scientific and Technical Information of China (English)

    田爱琴; 孙洪博; 陈文涛; 王琳

    2012-01-01

    Based on vapor-liquid phase equilibria data for CO2+2-butanol binary system from 323K to 353K by constant-volume visual high-pressure cell, the solubility model of CO2 in 2-butanol was established with Krichevsky-Kasarnovsky equation. Henry's coefficients and partial molar volumes of CO2 at infinite dilution were calculated. Meanwhile, Partial molar volumes of CO2 and 2-butanol at equilibrium were calculated from partial molar volumes properties together with Peng-Robinson equation of state and Van der Waals-2 mixed rule. The results showed that Henry's coefficients and partial molar volumes of CO2 at infinite dilution were both the function of temperature, and Henry's coefficients decreased with temperature. The partial molar volumes of CO2 at infinite dilution were negative and the magnitudes decreased with temperature. The calculated effects of partial molar volumes of vapor and liquid phase at equilibrium showed that the partial molar volumes of CO2 and 2-butanol in liquid phase were positive, but in vapor the partial molar volumes of CO2 were negative and the partial molar volumes of 2-butanol were positive. The research provided theoretical basis for deciding supercritical extraction conditions and instructing industrial production.%利用固定体积可视高压釜测量出的在323 K~353 K温度范围内的CO2与2-丁醇二元体系在高压下的汽液相平衡数据,根据Krichevsky-Kasarnovsky方程建立了CO2在液相中的溶解度模型,得到了该二元体系在高压下的亨利系数和CO2在无限稀释溶液中的偏摩尔体积等性质.同时根据偏摩尔体积性质和Peng-Robinson状态方程及Van der Waals-2混合规则来计算该体系在平衡状态下的气、液相的偏摩尔体积.结果表明CO2在2-丁醇中的亨利系数和CO2在无限稀释溶液中的偏摩尔体积均为温度的函数,CO2在2-丁醇中的亨利系数随温度的升高而降低.CO2在无限稀释溶液中的偏摩尔体积(V)1∞在研究温度下均为

  19. Form of multicomponent Fickian diffusion coefficients matrix

    International Nuclear Information System (INIS)

    Wambui Mutoru, J.; Firoozabadi, Abbas

    2011-01-01

    Highlights: → Irreversible thermodynamics establishes form of multicomponent diffusion coefficients. → Phenomenological coefficients and thermodynamic factors affect sign of diffusion coefficients. → Negative diagonal elements of diffusion coefficients matrix can occur in non-ideal mixtures. → Eigenvalues of the matrix of Fickian diffusion coefficients may not be all real. - Abstract: The form of multicomponent Fickian diffusion coefficients matrix in thermodynamically stable mixtures is established based on the form of phenomenological coefficients and thermodynamic factors. While phenomenological coefficients form a symmetric positive definite matrix, the determinant of thermodynamic factors matrix is positive. As a result, the Fickian diffusion coefficients matrix has a positive determinant, but its elements - including diagonal elements - can be negative. Comprehensive survey of reported diffusion coefficients data for ternary and quaternary mixtures, confirms that invariably the determinant of the Fickian diffusion coefficients matrix is positive.

  20. The effects of intraoperative lung protective ventilation with positive end-expiratory pressure on blood loss during hepatic resection surgery: A secondary analysis of data from a published randomised control trial (IMPROVE).

    Science.gov (United States)

    Neuschwander, Arthur; Futier, Emmanuel; Jaber, Samir; Pereira, Bruno; Eurin, Mathilde; Marret, Emmanuel; Szymkewicz, Olga; Beaussier, Marc; Paugam-Burtz, Catherine

    2016-04-01

    During high-risk abdominal surgery the use of a multi-faceted lung protective ventilation strategy composed of low tidal volumes, positive end-expiratory pressure (PEEP) and recruitment manoeuvres, has been shown to improve clinical outcomes. It has been speculated, however, that mechanical ventilation using PEEP might increase intraoperative bleeding during liver resection. To study the impact of mechanical ventilation with PEEP on bleeding during hepatectomy. Post-hoc analysis of a randomised controlled trial. Seven French university teaching hospitals from January 2011 to August 2012. Patients scheduled for liver resection surgery. In the Intraoperative Protective Ventilation trial, patients scheduled for major abdominal surgery were randomly assigned to mechanical ventilation using low tidal volume, PEEP between 6 and 8  cmH2O and recruitment manoeuvres (lung protective ventilation strategy) or higher tidal volume, zero PEEP and no recruitment manoeuvres (non-protective ventilation strategy). The primary endpoint was intraoperative blood loss volume. A total of 79 (19.8%) patients underwent liver resections (41 in the lung protective and 38 in the non-protective group). The median (interquartile range) amount of intraoperative blood loss was 500 (200 to 800)  ml and 275 (125 to 800)  ml in the non-protective and lung protective ventilation groups, respectively (P = 0.47). Fourteen (35.0%) and eight (21.5%) patients were transfused in the non-protective and lung protective groups, respectively (P = 0.17), without a statistically significant difference in the median (interquartile range) number of red blood cells units transfused [2.5 (2 to 4) units and 3 (2 to 6) units in the two groups, respectively; P = 0.54]. During hepatic surgery, mechanical ventilation using PEEP within a multi-faceted lung protective strategy was not associated with increased bleeding compared with non-protective ventilation using zero PEEP. The current study was not

  1. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  2. Transfer coefficients for plate fin and elliptical tube heat exchangers

    International Nuclear Information System (INIS)

    Saboya, S.M.; Saboya, F.E.M.

    1981-01-01

    In order to determine transfer coefficients for plate fin and elliptical tube exchangers, mass transfer experiments have been performed using the naphthalene sublimation technique. By means of the heat-mass transfer analogy, the results can be converted to heat transfer results. The transfer coefficients were compared with those for circular tube exchangers and the comparison revealed no major differences. This is a positive outcome, since the use of elliptical tubes may reduce substantially the pressure drop, without affecting the transfer characteristics.(Author) [pt

  3. Study of transport coefficients of nanodiamond nanofluids

    Science.gov (United States)

    Pryazhnikov, M. I.; Minakov, A. V.; Guzei, D. V.

    2017-09-01

    Experimental data on the thermal conductivity coefficient and viscosity coefficient of nanodiamond nanofluids are presented. Distilled water and ethylene glycol were used as the base fluid. Dependences of transport coefficients on concentration are obtained. It was shown that the thermal conductivity coefficient increases with increasing nanodiamonds concentration. It was shown that base fluids properties and nanodiamonds concentration affect on the rheology of nanofluids.

  4. Evaluation of Rock Joint Coefficients

    Science.gov (United States)

    Audy, Ondřej; Ficker, Tomáš

    2017-10-01

    A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.

  5. Investigation on Thrust and Moment Coefficients of a Centrifugal Turbomachine

    Directory of Open Access Journals (Sweden)

    Bo Hu

    2018-04-01

    Full Text Available In radial pumps and turbines, the centrifugal through-flow in both the front and the back chambers is quite common. It strongly impacts the core swirl ratio, pressure distribution, axial thrust and frictional torque. In order to investigate these relationships experimentally, a test rig was designed at the University of Duisburg-Essen and described in this paper. Based on both the experimental and numerical results, correlations are determined to predict the impacts of the centrifugal through-flow on the core swirl ratio, the thrust coefficient and the moment coefficient. Two correlations respectively are determined to associate the core swirl ratio with the local through-flow coefficient for both Batchelor type flow and Stewartson type flow. The correlations describing the thrust coefficient and the moment coefficient in a rotor-stator cavity with centripetal through-flow (Hu et al., 2017 are modified for the case of centrifugal through-flow. The Daily and Nece diagram distinguishing between different flow regimes in rotor-stator cavities is extended with a through-flow coordinate into 3D. The achieved results provide a comprehensive data base which is intended to support the calculation of axial thrust and moment coefficients during the design process of radial pumps and turbines in a more accurate manner.

  6. Relationship between the evaporation rate and vapor pressure of moderately and highly volatile chemicals.

    Science.gov (United States)

    van Wesenbeeck, Ian; Driver, Jeffrey; Ross, John

    2008-04-01

    Volatilization of chemicals can be an important form of dissipation in the environment. Rates of evaporative losses from plant and soil surfaces are useful for estimating the potential for food-related dietary residues and operator and bystander exposure, and can be used as source functions for screening models that predict off-site movement of volatile materials. A regression of evaporation on vapor pressure from three datasets containing 82 pesticidal active ingredients and co-formulants, ranging in vapor pressure from 0.0001 to >30,000 Pa was developed for this purpose with a regression correlation coefficient of 0.98.

  7. Correlation coefficients in neutron β-decay

    International Nuclear Information System (INIS)

    Byrne, J.

    1978-01-01

    The various angular and polarisation coefficients in neutron decay are the principal sources of information on the β-interaction. Measurements of the electron-neutrino angular correlation coefficient (a), the neutron-spin-electron-momentum correlation coefficient (A), the neutron-spin-neutrino-momentum correlation coefficient (B), and the triple correlation coefficient D and time-reversal invariance are reviewed and the results discussed. (U.K.)

  8. Ion heat conduction losses in Extrap

    International Nuclear Information System (INIS)

    Tennfors, E.

    1989-08-01

    The classical ion heat conduction losses in Extrap discharges are calculated using polynomial magnetic field profiles and compared to the power input. For polynomials matched to magnetic field profiles measured in present experiments, these losses are small. By varying the coefficients of the polynomials, a region is found, where the power input can balance the classical heat conduction losses. Each set of coefficients corresponds to values of the parameters F and Θ used in RFP physics. The region determines a region in an F-Θ diagram, including the usual RFP region but extending to higher values of Θ and βΘ

  9. 1/5-scale experiment of a Mark I boiling-water reactor pressure-suppression system under hypothetical LOCA conditions

    International Nuclear Information System (INIS)

    Pitts, J.H.; McCauley, E.W.

    1977-01-01

    Experimental results show the sensitivity of hydrodynamically generated vertical loads to changes in the drywell pressurization rate, downcomer submergence, and vent-line loss coefficient. Insignificant effects on peak vertical loads were observed when the vent-line loss was varied. Peak vertical loads can be reduced by adding initial drywell overpressure so that the downcomers are partly cleared of water. Spatial variation of pressure at about the time of vent clearing is seen in comparisons of data from locations along the axis of the toroidal wetwell

  10. Water Loss in Small Settlements

    OpenAIRE

    Mindaugas Rimeika; Anželika Jurkienė

    2014-01-01

    The main performance indicators of a water supply system include the quality and safety of water, continuous work, relevant pressure and small water loss. The majority of foreign and local projects on reducing water loss have been carried out in the water supply systems of metropolitans; however, the specificity of small settlements differs from that of big cities. Differences can be observed not only in the development of infrastructure and technical indicators but also in the features of wa...

  11. Tempus fugit : Time pressure in risky decisions

    NARCIS (Netherlands)

    Kocher, M.G.; Pahlke, J.; Trautmann, S.T.

    2013-01-01

    We study the effects of time pressure on risky decisions for pure gain prospects, pure loss prospects, and mixed prospects involving both gains and losses. In two experiments we find that time pressure has no effect on risk attitudes for gains, but increases risk aversion for losses. For mixed

  12. Induration and Biot’s Coefficient of Palaeogene Limestone

    DEFF Research Database (Denmark)

    Andreassen, Katrine Alling

    2017-01-01

    In engineering geology and classification of rock masses for civil engineering purposes, the degree of induration for a rock serves as a useful classification parameter. Induration is a measure of how well the grains of a sedimentary rock are cemented together - from loosely cemented/soft rock...... to very competent/slightly metamorphic rock. The Biot coefficient links to the degree of cementation in the capacity of how it relates the elastic deformations with the change in pore pressure. A hypothesis is that the degree of induration could be correlated to the magnitude of the Biot coefficient....... This is tested on 11 Copenhagen Limestone specimens of varying porosity and densities obtained from one borehole with a limestone interval of 30 m. Their induration varies from H2 to H5. Elastic wave propagation measurements are used to establish the Biot coefficient and determination of the mineralogy for H5...

  13. Numerical study on over reading coefficient in wet steam flow measurement

    International Nuclear Information System (INIS)

    Bai Xuesong; Yuan Dewen; Yan Xiao; Peng Xingjian

    2013-01-01

    This paper investigated the flow process of wet steam in Venturi under interested conditions with CFD simulation software. The effect of pressure, mass flow rate, throat radius on over reading factor was analyzed. This paper aims to improve the wet steam over reading model and the prediction accuracy in wet steam. The results prove that the mass flow has a small effect on over reading coefficient, while the effect that throat radius has on over reading coefficient increases as the pressure rises. (authors)

  14. Permeability and Dispersion Coefficients in Rocks with Fracture Network - 12140

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.K.; Htway, M.Z. [Handong Global University, 3 Namsong-ri, Heunghae-eub, Buk-gu, Pohang, Kyungbuk, 791-708 (Korea, Republic of); Yim, S.P. [Korea Atomic Energy Research Institute, P.O.Box 150, Yusong, Daejon, 305-600 (Korea, Republic of)

    2012-07-01

    Fluid flow and solute transport are considered for a rock medium with a fracture network with regard to the effective permeability and the dispersion coefficients. To investigate the effects of individual fractures a three-fracture system is chosen in which two are parallel and the third one connects the two at different angles. Specifically the micro-cell boundary-value problems(defined through multiple scale analysis) are solved numerically by using finite elements to calculate the permeability and dispersion coefficients. It is shown that the permeability depends significantly on the pattern of the fracture distribution and the dispersion coefficient is influenced by both the externally imposed pressure gradient (which also reflects the flow field) and the direction of the gradient of solute concentration on the macro-scale. From the calculations of the permeability and dispersion coefficients for solute in a rock medium with a fracture network the following conclusions are drawn. 1. The permeability of fractured medium depends on the primary orientation of the fracture network and is influenced by the connecting fractures in the medium. 2. The cross permeability, e.g., permeability in the direction normal to the direction of the external pressure gradient is rather insensitive to the orientation of the fracture network. 3. Calculation of permeability is most efficiently achieved with optimal discretization across individual fractures and is rather insensitive to the discretization along the fracture.. 4. The longitudinal dispersion coefficient Dxx of a fractured medium depends on both the macro-scale concentration gradient and the direction of the flow (pressure gradient). Hence both features must be considered when investigating solute transport in a fractured medium. (authors)

  15. Extinction Coefficient of Gold Nanostars.

    Science.gov (United States)

    de Puig, Helena; Tam, Justina O; Yen, Chun-Wan; Gehrke, Lee; Hamad-Schifferli, Kimberly

    2015-07-30

    Gold nanostars (NStars) are highly attractive for biological applications due to their surface chemistry, facile synthesis and optical properties. Here, we synthesize NStars in HEPES buffer at different HEPES/Au ratios, producing NStars of different sizes and shapes, and therefore varying optical properties. We measure the extinction coefficient of the synthesized NStars at their maximum surface plasmon resonances (SPR), which range from 5.7 × 10 8 to 26.8 × 10 8 M -1 cm -1 . Measured values correlate with those obtained from theoretical models of the NStars using the discrete dipole approximation (DDA), which we use to simulate the extinction spectra of the nanostars. Finally, because NStars are typically used in biological applications, we conjugate DNA and antibodies to the NStars and calculate the footprint of the bound biomolecules.

  16. Kerr scattering coefficients via isomonodromy

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Bruno Carneiro da [Departamento de Física, Universidade Federal de Pernambuco,50670-901, Recife, Pernambuco (Brazil); Novaes, Fábio [International Institute of Physics, Federal University of Rio Grande do Norte,Av. Odilon Gomes de Lima 1722, Capim Macio, Natal-RN 59078-400 (Brazil)

    2015-11-23

    We study the scattering of a massless scalar field in a generic Kerr background. Using a particular gauge choice based on the current conservation of the radial equation, we give a generic formula for the scattering coefficient in terms of the composite monodromy parameter σ between the inner and the outer horizons. Using the isomonodromy flow, we calculate σ exactly in terms of the Painlevé V τ-function. We also show that the eigenvalue problem for the angular equation (spheroidal harmonics) can be calculated using the same techniques. We use recent developments relating the Painlevé V τ-function to Liouville irregular conformal blocks to claim that this scattering problem is solved in the combinatorial sense, with known expressions for the τ-function near the critical points.

  17. Loss-of-normal-feedwater sensitivity studies for AP600 behavior characterization

    International Nuclear Information System (INIS)

    Saiu, G.

    1996-01-01

    Activity concerning the development of a RELAP5/MOD3 model to simulate the Westinghouse Electric Corporation AP600 is summarized. The aim is to gain initial insight into the capability of RELAP5 to simulate the behavior of AP600 safety features. A-loss-of-normal-feedwater event is studied. Of the transients that must be investigated, this transient has been chosen to be one of the most relevant because the response of the AP600 to a loss-of-normal-feedwater event differs significantly from that of current pressurized water reactors in the extensive use of passive safety features peculiar to the AP600. Also, strong interactions among the AP600 safety systems, which should be further analyzed to permit full optimization of the system actuation logic and operation, are shown. Finally, a loss of normal feedwater without reactor scram, performed to investigate short-term plant behavior, shows that the pressure peak is affected by critical discharge flow coefficients applied to the pressurizer safety valves, while a relatively small reduction of the pressure peak is observed when both heat exchangers of the passive heat removal system are operating as opposed to the case in which only one is available. The data used for this study are derived from the Standard Safety Analysis Report configuration of the Westinghouse AP600 as of 1992

  18. Measurement of attenuation coefficients of the fundamental and second harmonic waves in water

    Science.gov (United States)

    Zhang, Shuzeng; Jeong, Hyunjo; Cho, Sungjong; Li, Xiongbing

    2016-02-01

    Attenuation corrections in nonlinear acoustics play an important role in the study of nonlinear fluids, biomedical imaging, or solid material characterization. The measurement of attenuation coefficients in a nonlinear regime is not easy because they depend on the source pressure and requires accurate diffraction corrections. In this work, the attenuation coefficients of the fundamental and second harmonic waves which come from the absorption of water are measured in nonlinear ultrasonic experiments. Based on the quasilinear theory of the KZK equation, the nonlinear sound field equations are derived and the diffraction correction terms are extracted. The measured sound pressure amplitudes are adjusted first for diffraction corrections in order to reduce the impact on the measurement of attenuation coefficients from diffractions. The attenuation coefficients of the fundamental and second harmonics are calculated precisely from a nonlinear least squares curve-fitting process of the experiment data. The results show that attenuation coefficients in a nonlinear condition depend on both frequency and source pressure, which are much different from a linear regime. In a relatively lower drive pressure, the attenuation coefficients increase linearly with frequency. However, they present the characteristic of nonlinear growth in a high drive pressure. As the diffraction corrections are obtained based on the quasilinear theory, it is important to use an appropriate source pressure for accurate attenuation measurements.

  19. Pressure drop performance evaluation for test assemblies with the newly developed top and bottom nozzles

    International Nuclear Information System (INIS)

    Lee, S. K.; Park, N. K.; Su, J. M.; Kim, H. K.; Lee, J. N.; Kim, K. T.

    2003-01-01

    To perform the hydraulic test for the newly developed top and bottom nozzles, two kinds of test assemblies were manufactured i. e. one is the test assembly which has the newly developed top and bottom nozzles and the other is Guardian test assembly which is commercially in mass production now. The test results show that the test assembly with one top nozzle and two bottom nozzles has a greater pressure loss coefficient than Guardian test assembly by 60.9% and 90.4% at the bottom nozzle location. This cause is due to the debris filtering plate for bottom nozzle to improve a filtering efficiency aginst foreign material. In the region of mid grid and top nozzle, there is no difference in pressure loss coefficient between the test assemblies since the componet features in these regions are very similar or same each other. The loss coefficients are 14.2% and 21.9% for model A and B respectively in the scale of test assembly, and the value would be within the 10% in the scale of real fuel assembly. As a result of hydraulic performance evaluation, model A is superior to model B

  20. Factorization of Transport Coefficients in Macroporous Media

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Stenby, Erling Halfdan

    2000-01-01

    We prove the fundamental theorem about factorization of the phenomenological coefficients for transport in macroporous media. By factorization we mean the representation of the transport coefficients as products of geometric parameters of the porous medium and the parameters characteristic...

  1. Apparent Coefficient of Friction of Wheat on Denim.

    Science.gov (United States)

    Schwab, Charles V

    2017-07-31

    Calculation of the extraction force for a grain entrapment victim requires a coefficient of friction between the grain and the surface of the victim. Because denim is a common fabric for the work clothes that cover entrapment victims, the coefficient of friction between grain and denim becomes necessary. The purpose of this research was to calculate the apparent coefficient of friction of wheat on denim fabric using a proven procedure. The expectation is to improve the current understanding of conditions that influence extraction forces for victims buried in wheat. The apparent coefficient of friction of wheat on denim fabric was calculated to be 0.167 with a standard deviation of ±0.013. The wheat had a moisture content of 10.7% (w.b.) and bulk density of 778.5 kg m-3. The apparent coefficient of friction of wheat on denim was not significantly affected by pull speeds of 0.004, 0.008, and 0.021 mm s-1 nor normal grain pressures of 3.2, 4.8, 6.3, 7.9, and 11.1 kPa. This is a beginning of understanding the conditions that influence the extraction forces for grain entrapment victims. Copyright© by the American Society of Agricultural Engineers.

  2. Numerical study of effects of accommodation coefficients on slip phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Jae; Kwon, Oh Joon [KAIST, Daejeon (Korea, Republic of)

    2015-05-15

    An unstructured mesh Navier-Stokes solver employing a Maxwell slip boundary condition was developed. The present flow solver was applied to the simulation of flows around an axisymmetric hollow cylinder in a Mach 10.4 free stream, known as Calspan-UB Research Center (CUBRC) Run 14 case, and the velocity slip and the temperature jump on the cylinder surface were investigated. The effect of tangential momentum and thermal accommodation coefficients used in the Maxwell condition was also investigated by adjusting their values. The results show that the reverse flow region is developed on the body surface due to the interaction between the shock and the boundary layer. Also, the shock impingement makes pressure high. The flow properties on the surface agree well with the experimental data, and the velocity slip and the temperature jump vary consistently with the local Knudsen number change. The accommodation coefficients affect the slip phenomena and the size of the flow region. The slip phenomena become larger when both tangential momentum and thermal accommodation coefficients are decreased. However, the range of the reverse flow region decreases when the momentum accommodation coefficient is decreased. The characteristics of the momentum and thermal accommodation coefficients also are overlapped when they are altered together.

  3. Local, zero-power void coefficient measurements in the ACPR

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, J B; Thome, F V [Sandia Laboratories (United States)

    1974-07-01

    Changes in reactivity may be stimulated in the ACPR by the local introduction of voids into the reactor coolant. The local void coefficients of reactivity which describe this effect are of interest from a reactor safety point-of-view, and their determination is the subject of this presentation. Bottled nitrogen gas was used to produce the voids. The gas was forced out of a small diameter tube which was positioned vertically in the core lattice with its open end below the fuel. The gas was passed through a pressure regulator, a valve, and a flowmeter to establish a steady flow condition, following which a delayed-critical (zero-power) reactor state was established. Correlation of the average volume of core void created by the nitrogen flow with the reactivity worth of the delayed-critical control-rod bank position produced the values of the zero-power void coefficients of reactivity. The void coefficients were determined at various core positions from {approx}6 mm to 142 mm beyond the central irradiation space and for three different flow rates. For the range of void fractions investigated, these coefficients are negative, with values ranging between -$0.02 and -$0.12. Tabular and graphical results of the measurements are presented, and details of the coefficient determination are explained. (author)

  4. Local, zero-power void coefficient measurements in the ACPR

    International Nuclear Information System (INIS)

    Rivard, J.B.; Thome, F.V.

    1974-01-01

    Changes in reactivity may be stimulated in the ACPR by the local introduction of voids into the reactor coolant. The local void coefficients of reactivity which describe this effect are of interest from a reactor safety point-of-view, and their determination is the subject of this presentation. Bottled nitrogen gas was used to produce the voids. The gas was forced out of a small diameter tube which was positioned vertically in the core lattice with its open end below the fuel. The gas was passed through a pressure regulator, a valve, and a flowmeter to establish a steady flow condition, following which a delayed-critical (zero-power) reactor state was established. Correlation of the average volume of core void created by the nitrogen flow with the reactivity worth of the delayed-critical control-rod bank position produced the values of the zero-power void coefficients of reactivity. The void coefficients were determined at various core positions from ∼6 mm to 142 mm beyond the central irradiation space and for three different flow rates. For the range of void fractions investigated, these coefficients are negative, with values ranging between -$0.02 and -$0.12. Tabular and graphical results of the measurements are presented, and details of the coefficient determination are explained. (author)

  5. Determination of corneal elasticity coefficient using the ORA database.

    Science.gov (United States)

    Avetisov, Sergei E; Novikov, Ivan A; Bubnova, Irina A; Antonov, Alexei A; Siplivyi, Vladimir I

    2010-07-01

    To propose a new approach for the study of corneal biomechanics using the Reichert Ocular Response Analyzer (ORA) database, which is based on changes in velocity retardation in the central cornea at the peak of flattening. The ORA applanation curve was analyzed using a mathematical technique, which allowed calculation of the elasticity coefficient (Ke), which is primarily characteristic of the elastic properties of the cornea. Elasticity coefficient values were obtained in patients with presumably different biomechanical properties of the cornea: "normal" cornea (71 eyes, normal group), keratoconus (34 eyes, keratoconus group), LASIK (36 eyes, LASIK group), and glaucoma with elevated and compensated intraocular pressure (lOP) (38 eyes, glaucoma group). The mean Ke value in the normal group was 11.05 +/- 1.6, and the corneal thickness correlation coefficient r2 was 0.48. In the keratoconus group, the mean Ke value was 4.91 +/- 1.87 and the corneal thickness correlation coefficient r2 was 0.47. In the LASIK group, Ke and r2 were 5.99 +/- 1.18 and 0.39, respectively. In the glaucoma group, the same eyes that experienced a two-fold reduction in lOP developed a statistically significant reduction in the Ke (1.06 times lower), whereas their corneal hysteresis value increased 1.25 times. The elasticity coefficient calculated using the ORA applanation curve can be used in the evaluation of corneal biomechanical properties.

  6. Townsend coefficients of gases in avalanche counters

    International Nuclear Information System (INIS)

    Brunner, G.

    1978-01-01

    Though much work has been done by many authors in the last few years in the development and application of avalanche counters for ion radiation, it is based upon values of the Townsend coefficients as the essential gas parameter, which were determined many years ago for much lower reduced field strengths F/p than prevail in such counters. Therefore absolute determinations of α in vapours of methyl alcohol, cyclohexane, acetone, and n-heptene were performed under original conditions of avalanche counters. The values obtained do not differ by more than 30%-50% from the former values indeed, extrapolated over F/p for the first three mentioned substances, but the amounts of A and B in the usual representation α/p=A exp(-B(F/p)) are much greater for the stronger reduced fields. This is of importance for such counter properties as the dependence of pulse heights on pressure, voltage, electrode distance etc., which are governed by other combinations of A and B than α/p itself. A comparison of results for different ionic radiations shows a marked influence of the primary ionization density along the particle tracks which is hard to explain. (Auth.)

  7. Chondroitin sulfate reduces the friction coefficient of articular cartilage.

    Science.gov (United States)

    Basalo, Ines M; Chahine, Nadeen O; Kaplun, Michael; Chen, Faye H; Hung, Clark T; Ateshian, Gerard A

    2007-01-01

    The objective of this study was to investigate the effect of chondroitin sulfate (CS)-C on the frictional response of bovine articular cartilage. The main hypothesis is that CS decreases the friction coefficient of articular cartilage. Corollary hypotheses are that viscosity and osmotic pressure are not the mechanisms that mediate the reduction in the friction coefficient by CS. In Experiment 1, bovine articular cartilage samples (n=29) were tested in either phosphate buffered saline (PBS) or in PBS containing 100mg/ml of CS following 48h incubation in PBS or in PBS+100mg/ml CS (control specimens were not subjected to any incubation). In Experiment 2, samples (n=23) were tested in four different solutions: PBS, PBS+100mg/ml CS, and PBS+polyethylene glycol (PEG) (133 or 170mg/ml). In Experiment 3, samples (n=18) were tested in three solutions of CS (0, 10 and 100mg/ml). Frictional tests (cartilage-on-glass) were performed under constant stress (0.5MPa) for 3600s and the time-dependent friction coefficient was measured. Samples incubated or tested in a 100mg/ml CS solution exhibited a significantly lower equilibrium friction coefficient than the respective PBS control. PEG solutions delayed the rise in the friction coefficient relative to the PBS control, but did not reduce the equilibrium value. Testing in PBS+10mg/ml of CS did not cause any significant decrease in the friction coefficient. In conclusion, CS at a concentration of 100mg/ml significantly reduces the friction coefficient of bovine articular cartilage and this mechanism is neither mediated by viscosity nor osmolarity. These results suggest that direct injection of CS into the joint may provide beneficial tribological effects.

  8. Anomalous Seebeck coefficient in boron carbides

    International Nuclear Information System (INIS)

    Aselage, T.L.; Emin, D.; Wood, C.; Mackinnon, I.D.R.; Howard, I.A.

    1987-01-01

    Boron carbides exhibit an anomalously large Seebeck coefficient with a temperature coefficient that is characteristic of polaronic hopping between inequivalent sites. The inequivalence in the sites is associated with disorder in the solid. The temperature dependence of the Seebeck coefficient for materials prepared by different techniques provides insight into the nature of the disorder

  9. Standards for Standardized Logistic Regression Coefficients

    Science.gov (United States)

    Menard, Scott

    2011-01-01

    Standardized coefficients in logistic regression analysis have the same utility as standardized coefficients in linear regression analysis. Although there has been no consensus on the best way to construct standardized logistic regression coefficients, there is now sufficient evidence to suggest a single best approach to the construction of a…

  10. Soccer Ball Lift Coefficients via Trajectory Analysis

    Science.gov (United States)

    Goff, John Eric; Carre, Matt J.

    2010-01-01

    We performed experiments in which a soccer ball was launched from a machine while two high-speed cameras recorded portions of the trajectory. Using the trajectory data and published drag coefficients, we extracted lift coefficients for a soccer ball. We determined lift coefficients for a wide range of spin parameters, including several spin…

  11. Symmetry chains and adaptation coefficients

    International Nuclear Information System (INIS)

    Fritzer, H.P.; Gruber, B.

    1985-01-01

    Given a symmetry chain of physical significance it becomes necessary to obtain states which transform properly with respect to the symmetries of the chain. In this article we describe a method which permits us to calculate symmetry-adapted quantum states with relative ease. The coefficients for the symmetry-adapted linear combinations are obtained, in numerical form, in terms of the original states of the system and can thus be represented in the form of numerical tables. In addition, one also obtains automatically the matrix elements for the operators of the symmetry groups which are involved, and thus for any physical operator which can be expressed either as an element of the algebra or of the enveloping algebra. The method is well suited for computers once the physically relevant symmetry chain, or chains, have been defined. While the method to be described is generally applicable to any physical system for which semisimple Lie algebras play a role we choose here a familiar example in order to illustrate the method and to illuminate its simplicity. We choose the nuclear shell model for the case of two nucleons with orbital angular momentum l = 1. While the states of the entire shell transform like the smallest spin representation of SO(25) we restrict our attention to its subgroup SU(6) x SU(2)/sub T/. We determine the symmetry chains which lead to total angular momentum SU(2)/sub J/ and obtain the symmetry-adapted states for these chains

  12. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  13. Pressure drops in low pressure local boiling

    International Nuclear Information System (INIS)

    Courtaud, Michel; Schleisiek, Karl

    1969-01-01

    For prediction of flow reduction in nuclear research reactors, it was necessary to establish a correlation giving the pressure drop in subcooled boiling for rectangular channels. Measurements of pressure drop on rectangular channel 60 and 90 cm long and with a coolant gap of 1,8 and 3,6 mm were performed in the following range of parameters. -) 3 < pressure at the outlet < 11 bars abs; -) 25 < inlet temperature < 70 deg. C; -) 200 < heat flux < 700 W/cm 2 . It appeared that the usual parameter, relative length in subcooled boiling, was not sufficient to correlate experimental pressure losses on the subcooled boiling length and that there was a supplementary influence of pressure, heat flux and subcooling. With an a dimensional parameter including these terms a correlation was established with an error band of ±10%. With a computer code it was possible to derive the relation giving the overall pressure drop along the channel and to determine the local gradients of pressure drop. These local gradients were then correlated with the above parameter calculated in local conditions. 95 % of the experimental points were computed with an accuracy of ±10% with this correlation of gradients which can be used for non-uniform heated channels. (authors) [fr

  14. Low pressure lithium condensation

    International Nuclear Information System (INIS)

    Wadkins, R.P.; Oh, C.H.

    1985-01-01

    A low pressure experiment to evaluate the laminar film condensation coefficients of lithium was conducted. Some thirty-six different heat transfer tests were made at system pressures ranging from 1.3 to 26 Pa. Boiled lithium was condensed on the inside of a 7.6-cm (ID), 409 stainless-steel pipe. Condensed lithium was allowed to reflux back to the pool boiling region below the condensing section. Fourteen chromel/alumel thermocouples were attached in various regions of the condensing section. The thermocouples were initially calibrated with errors of less than one degree Celsius

  15. Pressure suppressing device

    International Nuclear Information System (INIS)

    Naito, Makoto.

    1980-01-01

    Purpose: To prevent the pressure in the reactor container from excessively increasing even when vapor leaks from the dry well to a space of the suppression chamber, without passing though the suppression pool at the time of loss of coolant accident. Constitution: When vapor of a high temperature and a high pressure at the time of loss of coolant accident flows from the dry well to the suppression chamber without passing through suppression pool water, vapor dose not condense with pool water, and therefore the pressure within the chamber abnormally increases. For this reason, this abnormal pressure is detected by a pressure detector thereby to start the operations of a blower and a pump. By starting the blower, the pressure in the dry well becomes lower than the pressure in the chamber, and vapor entirely passes through the pool water and entirely condenses with the pool water. By starting the pump, the pool water is sprayed over the space of the chamber, and vapor in the space is condensed. (Yoshino, Y.)

  16. Pressure wave propagation in the discharge piping with water pool

    International Nuclear Information System (INIS)

    Bang, Young S.; Seul, Kwang W.; Kim, In Goo

    2004-01-01

    Pressure wave propagation in the discharge piping with a sparger submerged in a water pool, following the opening of a safety relief valve, is analyzed. To predict the pressure transient behavior, a RELAP5/MOD3 code is used. The applicability of the RELAP5 code and the adequacy of the present modeling scheme are confirmed by simulating the applicable experiment on a water hammer with voiding. As a base case, the modeling scheme was used to calculate the wave propagation inside a vertical pipe with sparger holes and submerged within a water pool. In addition, the effects on wave propagation of geometric factors, such as the loss coefficient, the pipe configuration, and the subdivision of sparger pipe, are investigated. The effects of inflow conditions, such as water slug inflow and the slow opening of a safety relief valve are also examined

  17. Pressurized Anneal of Consolidated Powders

    Science.gov (United States)

    Nemir, David Charles (Inventor); Rubio, Edward S. (Inventor); Beck, Jan Bastian (Inventor)

    2017-01-01

    Systems and methods for producing a dense, well bonded solid material from a powder may include consolidating the powder utilizing any suitable consolidation method, such as explosive shockwave consolidation. The systems and methods may also include a post-processing thermal treatment that exploits a mismatch between the coefficients of thermal expansion between the consolidated material and the container. Due to the mismatch in the coefficients, internal pressure on the consolidated material during the heat treatment may be increased.

  18. Two-phased flow component loss data

    International Nuclear Information System (INIS)

    Fairhurst, C.P.

    1983-01-01

    Pressure loss measurements were made for valves and orifice plates under horizontal and vertical two-phase, air/water flow. The results displayed similar trends and were successfully correlated using a semi-empirical approach. (author)

  19. Calculation of Friction Coefficient and Analysis of Fluid Flow in a Stepped Micro-Channel for Wide Range of Knudsen Number Using Lattice Boltzmann (MRT Method

    Directory of Open Access Journals (Sweden)

    Y. Bakhshan

    2015-01-01

    Full Text Available Micro scale gas flows has attracted significant research interest in the last two decades. In this research, the fluid flow of gases in the stepped micro-channel at a wide range of Knudsen number has been analyzed with using the Lattice Boltzmann (MRT method. In the model, a modified second-order slip boundary condition and a Bosanquet-type effective viscosity are used to consider the velocity slip at the boundaries and to cover the slip and transition regimes of flow and to gain an accurate simulation of rarefied gases. It includes the slip and transition regimes of flow. The flow specifications such as pressure loss, velocity profile, streamline and friction coefficient at different conditions have been presented. The results show good agreement with available experimental data. The calculation shows that the friction coefficient decreases with increasing the Knudsen number and stepping the micro-channel has an inverse effect on the friction coefficient. Furthermore, a new correlation is suggested for calculation of the friction coefficient in the stepped micro-channel as below: C_f Re  = 3.113+2.915/(1 +2 Kn+ 0.641 exp⁡(3.203/(1 + 2 Kn

  20. Analysis study of the condensation heat transfer coefficient in the presence of noncondensable on PCCS vertical condenser tube using MARS-KS

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Dong jae; Jang, Yeong jun; Lee, Yeon-Gun [Jeju National University, Jeju (Korea, Republic of); Kim, Sin [Chung-Ang University, Seoul (Korea, Republic of)

    2015-10-15

    The Passive Containment Cooling System (PCCS) to be introduced in advanced LWRs removes released energy to an external heat sink by a naturally driven flow. Containment through the condensation heat transfer phenomenon in the event of the loss of coolant accident (LOCA) or main steam line break (MSLB). As the released steam pressurizes the containment, the PCCS will activate to transport the decay heat In this study, a numerical analysis of the condensation heat transfer coefficients on the PCCS condenser tube is conducted using the MARS-KS code. The condensation heat transfer coefficients are obtained from JNU condensation tests performed on a 1000 long and 40 mm O.D. tube. The analysis condition covers 2 and 4 bar for the air mass fraction ranging from 0.1 to 0.8. The JNU single vertical condensation experimental results, Uchida's and Dehbi's correlation compared with the MARS-KS code's results at 2 and 4 bar. Experimental results and MARS-KS predicted heat transfer coefficient is different from the thermal resistances and Wall subcooling. An average relative error is 18.8% and 15% at 2 and 4 bar, respectively. Uchida's correlation is considered the noncondensable gas mass fraction only. Therefore, that is lower than MARS-KS results at 4 bar. Dehbi's correlation affected by ratio of the height-to-diameter, so its results are higher condensation heat transfer coefficient than MARS-KS predicted results.

  1. Living with vision loss

    Science.gov (United States)

    Diabetes - vision loss; Retinopathy - vision loss; Low vision; Blindness - vision loss ... of visual aids. Some options include: Magnifiers High power reading glasses Devices that make it easier to ...

  2. Wind shear coefficients and their effect on energy production

    International Nuclear Information System (INIS)

    Rehman, Shafiqur; Al-Abbadi, Naif M.

    2005-01-01

    This paper provides realistic values of wind shear coefficients calculated using measured values of wind speed at 20, 30 and 40 m above the ground for the first time in Saudi Arabia in particular and, to the best of the authors' knowledge, in the Gulf region in general. The paper also presents air density values calculated using the measured air temperature and surface pressure and the effects of wind shear factor on energy production from wind machines of different sizes. The measured data used in the study covered a period of almost three years between June 17, 1995 and December 1998. An overall mean value of wind shear coefficient of 0.194 can be used with confidence to calculate the wind speed at different heights if measured values are known at one height. The study showed that the wind shear coefficient is significantly influenced by seasonal and diurnal changes. Hence, for precise estimations of wind speed at a height, both monthly or seasonal and hourly or night time and day time average values of wind shear coefficient must be used. It is suggested that the wind shear coefficients must be calculated either (i) using long term average values of wind speed at different heights or (ii) using those half hourly mean values of wind speed for which the wind shear coefficient lies in the range 0 and 0.51. The air density, calculated using measured temperature and pressure was found to be 1.18 kg/m 3 . The air density values were also found to vary with the season of the year and hour of the day, and hence, care must be taken when precise calculations are to be made. The air density values, as shown in this paper, have no significant variation with height. The energy production analysis showed that the actual wind shear coefficient presented in this paper produced 6% more energy compared to that obtained using the 1/7 power law. Similarly, higher plant capacity factors were obtained with the wind shear factor of 0.194 compared to that with 0.143

  3. Study for discharge coefficient of flow nozzles. Prediction by using numerical simulation

    International Nuclear Information System (INIS)

    Ikeda, Hiroshi; Sakai, Norio; Yamamoto, Yasushi; Arai, Kenji; Matsumoto, Masaaki

    2008-01-01

    In nuclear plant, as water feeding into reactor have much effect on thermal power of plant, it is important to measure accurately the flow rate of water. Flow nozzle is on of typical differential pressure type flow meters and the discharge coefficient is used to calculate the flow rate. This coefficient is given by actual experiment and theory. We studied the theoretical assumption of the discharge coefficient curve using numerical simulation and evaluated the effect of flow nozzle configuration on the coefficient numerically and experimentally. As the result, numerical simulation can predict the discharge coefficient of theoretical curve within 0.3%. And we found that the throat length and throat tapping location of flow nozzle have much effect on the coefficient. (author)

  4. A drying coefficient for building materials

    DEFF Research Database (Denmark)

    Scheffler, Gregor Albrecht; Plagge, Rudolf

    2009-01-01

    coefficient is defined which can be determined based on measured drying data. The correlation of this coefficient with the water absorption and the vapour diffusion coefficient is analyzed and its additional information content is critically challenged. As result, a drying coefficient has been derived......The drying experiment is an important element of the hygrothermal characterisation of building materials. Contrary to other moisture transport experiments as the vapour diffusion and the water absorption test, it is until now not possible to derive a simple coefficient for the drying. However......, in many cases such a coefficient would be highly appreciated, e.g. in interaction of industry and research or for the distinction and selection of suitable building materials throughout design and practise. This article first highlights the importance of drying experiments for hygrothermal...

  5. Apparatus for measurement of coefficient of friction

    Science.gov (United States)

    Slifka, A. J.; Siegwarth, J. D.; Sparks, L. L.; Chaudhuri, Dilip K.

    1990-01-01

    An apparatus designed to measure the coefficient of friction in certain controlled atmospheres is described. The coefficient of friction observed during high-load tests was nearly constant, with an average value of 0.56. This value is in general agreement with that found in the literature and also with the initial friction coefficient value of 0.67 measured during self-mated friction of 440C steel in an oxygen environment.

  6. New definition of the cell diffusion coefficient

    International Nuclear Information System (INIS)

    Koehler, P.

    1975-01-01

    As was shown in a recent work by Gelbard, the usually applied Benoist definition of the cell diffusion coefficient gives two different values if two different definitions of the cell are made. A new definition is proposed that preserves the neutron balance for the homogenized lattice and that is independent of the cell definition. The resulting diffusion coefficient is identical with the main term of Benoist's diffusion coefficient

  7. Measurement and modeling of interface heat transfer coefficients

    International Nuclear Information System (INIS)

    Rollett, A.D.; Lewis, H.D.; Dunn, P.S.

    1985-01-01

    The results of preliminary work on the modeling and measurement of the heat transfer coefficients of metal/mold interfaces is reported. The system investigated is the casting of uranium in graphite molds. The motivation for the work is primarily to improve the accuracy of process modeling of prototype mold designs at the Los Alamos Foundry. The evolution in design of a suitable mold for unidirectional solidification is described, illustrating the value of simulating mold designs prior to use. Experiment indicated a heat transfer coefficient of 2 kW/m 2 /K both with and without superheat. It was possible to distinguish between solidification due to the mold and that due to radiative heat loss. This permitted an experimental estimate of the emissivity, epsilon = 0.2, of the solidified metal

  8. Coefficient of restitution of sports balls: A normal drop test

    International Nuclear Information System (INIS)

    Haron, Adli; Ismail, K A

    2012-01-01

    Dynamic behaviour of bodies during impact is investigated through impact experiment, the simplest being a normal drop test. Normally, a drop test impact experiment involves measurement of kinematic data; this includes measurement of incident and rebound velocity in order to calculate a coefficient of restitution (COR). A high speed video camera is employed for measuring the kinematic data where speed is calculated from displacement of the bodies. Alternatively, sensors can be employed to measure speeds, especially for a normal impact where there is no spin of the bodies. This paper compares experimental coefficients of restitution (COR) for various sports balls, namely golf, table tennis, hockey and cricket. The energy loss in term of measured COR and effects of target plate are discussed in relation to the material and construction of these sports balls.

  9. Transfer coefficients in ultracold strongly coupled plasma

    Science.gov (United States)

    Bobrov, A. A.; Vorob'ev, V. S.; Zelener, B. V.

    2018-03-01

    We use both analytical and molecular dynamic methods for electron transfer coefficients in an ultracold plasma when its temperature is small and the coupling parameter characterizing the interaction of electrons and ions exceeds unity. For these conditions, we use the approach of nearest neighbor to determine the average electron (ion) diffusion coefficient and to calculate other electron transfer coefficients (viscosity and electrical and thermal conductivities). Molecular dynamics simulations produce electronic and ionic diffusion coefficients, confirming the reliability of these results. The results compare favorably with experimental and numerical data from earlier studies.

  10. Comparing linear probability model coefficients across groups

    DEFF Research Database (Denmark)

    Holm, Anders; Ejrnæs, Mette; Karlson, Kristian Bernt

    2015-01-01

    of the following three components: outcome truncation, scale parameters and distributional shape of the predictor variable. These results point to limitations in using linear probability model coefficients for group comparisons. We also provide Monte Carlo simulations and real examples to illustrate......This article offers a formal identification analysis of the problem in comparing coefficients from linear probability models between groups. We show that differences in coefficients from these models can result not only from genuine differences in effects, but also from differences in one or more...... these limitations, and we suggest a restricted approach to using linear probability model coefficients in group comparisons....

  11. Rate Coefficient Measurements and Theoretical Analysis of the OH + ( E) CF3CH=CHCF3 Reaction.

    Science.gov (United States)

    Baasandorj, Munkhbayar; Marshall, Paul; Waterland, Robert L; Ravishankara, Akkihebbal R; Burkholder, James B

    2018-04-25

    Rate coefficients, k, for the gas-phase reaction of the OH radical with (E) CF3CH=CHCF3 ((E)-1,1,14,4,4-hexafluoro-2-butene, HFO-1336mzz(E)) were measured over a range of temperature (211-374 K) and bath gas pressure (20-300 Torr; He, N2) using a pulsed laser photolysis-laser induced fluorescence (PLP-LIF) technique. k1(T) was independent of pressure over this range of conditions with k1(296 K) = (1.31 ± 0.15) × 10 13 cm3 molecule 1 s 1 and k1(T) = (6.94 ± 0.80) × 10 13 exp[ (496 ± 10)/T] cm3 molecule 1 s 1, where the uncertainties are 2 and the pre-exponential term includes estimated systematic error. Rate coefficients for the OD reaction were also determined over a range of temperature (262-374 K) at 100 Torr (He). The OD rate coefficients were ~15% greater than the OH values and showed similar temperature dependent behavior with k2(T) = (7.52 ± 0.44) × 10 13 exp[ (476 ± 20)/T] and k2(296 K) = (1.53 ± 0.15) × 10 13 cm3 molecule 1 s 1. The rate coefficients for reaction 1 were also measured using a relative rate technique between 296 and 375 K with k1(296 K) measured to be (1.22 ± 0.1) × 10 13 cm3 molecule 1 s 1 in agreement with the PLP-LIF results. In addition, the 296 K rate coefficient for the O3 + (E) CF3CH=CHCF3 reaction was determined to be reaction and the significant decrease in OH reactivity compared to the (Z) CF3CH=CHCF3 stereoisomer reaction. The estimated atmospheric lifetime of (E) CF3CH=CHCF3, due to loss by reaction with OH, is estimated to be ~90 days, while the actual lifetime will depend on the location and season of its emission. Infrared absorption spectra of (E) CF3CH=CHCF3 were measured and used to estimate the 100-year time horizon global warming potentials (GWP) of 32 (atmospherically well-mixed) and 14 (lifetime-adjusted).

  12. Contribution to the evaluation of diffusion coefficients in plasmas containing argon and fluorine

    International Nuclear Information System (INIS)

    Novakovic, N V

    2006-01-01

    The theoretical values of the numerical evaluation of the electron and ion diffusion coefficients in plasmas from mixtures of argon and fluorine are presented. The temperature dependence of the diffusion coefficients for low-pressure (from 0.1 to 1.0 kPa) and low-temperature (from 500 to 5000 K) argon plasmas with 20% and 30% of added fluorine are investigated. These values are results of the applications of the specific numerical model to the evaluation plasma composition and transport coefficients in argon plasma with fluorine as additive. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE) is attained. Since the LTE can be assumed, a Maxwellian electron distribution function will be adopted. The hypothesis of LTE, which is commonly used in most of the numerical evaluations, is analysed with the modified Debye radius r D *. The binary electron and ion diffusion coefficients are calculated with the equilibrium plasma composition and with the collision frequencies. Strictly speaking, Maxwellian distribution function (in the state LTE) is not valid for low pressure, but in this case with the aid of the modified Debye radius, a Maxwellian f e M is assumed correctly. It is shown that the electron diffusion coefficients are about four orders of magnitude larger than the corresponding overall diffusion coefficients of ions. Both diffusion coefficients are lower in argon plasma with 30% than with 20% of fluorine additives, in the whole temperature range examined

  13. An experimental approach of decoupling Seebeck coefficient and electrical resistivity

    Science.gov (United States)

    Muhammed Sabeer N., A.; Paulson, Anju; Pradyumnan, P. P.

    2018-04-01

    The Thermoelectrics (TE) has drawn increased attention among renewable energy technologies. The performance of a thermoelectric material is quantified by a dimensionless thermoelectric figure of merit, ZT=S2σT/κ, where S and σ vary inversely each other. Thus, improvement in ZT is not an easy task. So, researchers have been trying different parameter variations during thin film processing to improve TE properties. In this work, tin nitride (Sn3N4) thin films were deposited on glass substrates by reactive RF magnetron sputtering and investigated its thermoelectric response. To decouple the covariance nature of Seebeck coefficient and electrical resistivity for the enhancement of power factor (S2σ), the nitrogen gas pressure during sputtering was reduced. Reduction in nitrogen gas pressure reduced both sputtering pressure and amount of nitrogen available for reaction during sputtering. This experimental approach of combined effect introduced preferred orientation and stoichiometric variations simultaneously in the sputtered Sn3N4 thin films. The scattering mechanism associated with these variations enhanced TE properties by independently drive the Seebeck coefficient and electrical resistivity parameters.

  14. Hair Loss (Alopecia)

    Science.gov (United States)

    ... care Kids’ zone Video library Find a dermatologist Hair loss Overview Hereditary hair loss: Millions of men ... of hair loss can often be successfully treated. Hair loss: Overview Also called alopecia (al-o-PEE- ...

  15. Characterization of the frictional losses and heat transfer of oscillatory viscous flow through wire-mesh regenerators

    Directory of Open Access Journals (Sweden)

    A.A. Boroujerdi

    2015-12-01

    Full Text Available In this paper, new relations for calculating heat transfer and pressure drop characteristics of oscillatory flow through wire-mesh screen regenerator such as Darcy permeability, Forchheimer’s inertial coefficient, and heat transfer area per unit volume, as a function of the wire diameter are presented. According to the derived relations, thinner wires have higher pressure drop and higher heat transfer rate. The relations are applicable for all regenerative cryocoolers. Embedding the new relations into a numerical model, three Stirling-type orifice pulse tube cryocoolers with three regenerators different in length and diameter but same volume in a variety of wire diameters, have been modeled. The results achieved by the model reveal that the local heat transfer coefficient decreases with increase of the wire diameter and the length-to-diameter ratio. In addition, it was shown that the mean absolute gas–solid wire temperature difference is a linear function of wire diameter in the range investigated. The results show that for larger length-to-diameter ratios, Forchheimer’s effect will dominate frictional losses, and the variations of the frictional losses are proportional to the inverse of the wire diameter. Wire diameter has been optimized to maximize the coefficient of performance of the cryocooler. Shorter regenerators have thinner optimum wires.

  16. Permeability coefficient of proton irradiated polyethylene terephatalate thin films

    International Nuclear Information System (INIS)

    Bassani, L.C.; Santos, W.M.S.; Marechal, B.

    1983-01-01

    The principle of operation of an apparatus developed to study gas permation through thin films is described and the measurement method is discussed. Use is made of diffusion theory to obtain a expression for the permeability coefficient as a function of the rate of increase of the pressure in the receiving volume. The Gibbs function for permeation of Helium through Polyethylene Terephtalate (P.E.T.) is determined. The permeability coefficient of Helium is found to increase significantly with the range of the implanted protons although the incident charge has been kept constant. The hypothesis of structural modifications of the proton implanted P.E.T. seems to be confirmed by small angles X-rays scattering experiments on the irradiated samples. (Author) [pt

  17. Determination of quenching coefficients by time resolved emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gans, T.; Schulz-von der Gathen, V.; Doebele, H.F. [Essen Univ. (Gesamthochschule) (Germany). Inst. fuer Laser- und Plasmaphysik

    2001-07-01

    Capacitively coupled RF discharges (CCRF discharges) at 13.56 MHz in hydrogen exhibit a field reversal phase of about 10 ns during which an intense electron current provides collisional excitation, within the sheath region. After this strongly dominant short pulsed electron impact excitation, it is possible to determine quenching coefficients from the lifetime of the fluorescence at various pressures by time resolved OES even for high energy levels and without any restrictions of optical selection rules. This novel technique allows the measurement of quenching coefficients for atomic and molecular emission lines of hydrogen itself, as well as for emission lines of small admixtures (e.g. noble gases) to the hydrogen discharge, since with a fast gate-able ICCD camera operating at 13.56 MHz it is possible to measure even faint emission lines temporally resolved.

  18. Determination of quenching coefficients by time resolved emission spectroscopy

    International Nuclear Information System (INIS)

    Gans, T.; Schulz-von der Gathen, V.; Doebele, H.F.

    2001-01-01

    Capacitively coupled RF discharges (CCRF discharges) at 13.56 MHz in hydrogen exhibit a field reversal phase of about 10 ns during which an intense electron current provides collisional excitation, within the sheath region. After this strongly dominant short pulsed electron impact excitation, it is possible to determine quenching coefficients from the lifetime of the fluorescence at various pressures by time resolved OES even for high energy levels and without any restrictions of optical selection rules. This novel technique allows the measurement of quenching coefficients for atomic and molecular emission lines of hydrogen itself, as well as for emission lines of small admixtures (e.g. noble gases) to the hydrogen discharge, since with a fast gate-able ICCD camera operating at 13.56 MHz it is possible to measure even faint emission lines temporally resolved

  19. Evaporation of R407C and R410A in a horizontal herringbone microfin tube: heat transfer and pressure drop

    Energy Technology Data Exchange (ETDEWEB)

    Wellsandt, S; Vamling, L [Chalmers University of Technology, Gothenburg (Sweden). Department of Chemical Engineering and Environmental Science, Heat and Power Technology

    2005-09-01

    An experimental investigation of in-tube evaporation of R410A and R407C has been carried out for a 4 m long herringbone microfin tube with an outer diameter of 9.53 mm. Measured local heat transfer coefficients and pressure losses are reported for evaporation temperatures for R410A and R407C between -2.2 and 9.5 {sup o}C and between -5.5 and 13.8 {sup o}C, respectively. Mass flow rates between 162 and 366 kg m{sup -2} s{sup -1} have been investigated. Results from this work are compared to R134a data from an earlier work by the present authors, and also to predicted values from some available helical microfin correlations. Compared to R134a data, heat transfer coefficients for the investigated mixtures are generally lower, especially at low mass flow rates. No major effect of heat flux on heat transfer coefficients was found, with the exception of the high quality region. Predicted heat transfer coefficients from helical microfin correlations strongly overpredict the present data. Global pressure losses are predicted well, even though local deviations are found. (author)

  20. Estimation of radiation losses from sheathed thermocouples

    International Nuclear Information System (INIS)

    Roberts, I.L.; Coney, J.E.R.; Gibbs, B.M.

    2011-01-01

    Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950 o C. - Highlights: → Sheathed thermocouples are often used to measure temperatures in heat exchangers. → Errors are introduced if radiation losses are ignored. → Radiation losses are environment specific and may be significant. → Experimental and theoretical methods are used to estimate losses. → Hot side maximum temperature 950 o C.

  1. Resummed coefficient function for the shape function

    OpenAIRE

    Aglietti, U.

    2001-01-01

    We present a leading evaluation of the resummed coefficient function for the shape function. It is also shown that the coefficient function is short-distance-dominated. Our results allow relating the shape function computed on the lattice to the physical QCD distributions.

  2. Problems with Discontinuous Diffusion/Dispersion Coefficients

    Directory of Open Access Journals (Sweden)

    Stefano Ferraris

    2012-01-01

    accurate on smooth solutions and based on a special numerical treatment of the diffusion/dispersion coefficients that makes its application possible also when such coefficients are discontinuous. Numerical experiments confirm the convergence of the numerical approximation and show a good behavior on a set of benchmark problems in two space dimensions.

  3. Meta-Analysis of Coefficient Alpha

    Science.gov (United States)

    Rodriguez, Michael C.; Maeda, Yukiko

    2006-01-01

    The meta-analysis of coefficient alpha across many studies is becoming more common in psychology by a methodology labeled reliability generalization. Existing reliability generalization studies have not used the sampling distribution of coefficient alpha for precision weighting and other common meta-analytic procedures. A framework is provided for…

  4. Alternatives to Pearson's and Spearman's Correlation Coefficients

    OpenAIRE

    Smarandache, Florentin

    2008-01-01

    This article presents several alternatives to Pearson's correlation coefficient and many examples. In the samples where the rank in a discrete variable counts more than the variable values, the mixtures that we propose of Pearson's and Spearman's correlation coefficients give better results.

  5. Anomaly coefficients: Their calculation and congruences

    International Nuclear Information System (INIS)

    Braden, H.W.

    1988-01-01

    A new method for the calculation of anomaly coefficients is presented. For su(n) some explicit and general expressions are given for these. In particular, certain congruences are discovered and investigated among the leading anomaly coefficients. As an application of these congruences, the absence of global six-dimensional gauge anomalies is shown

  6. Prediction of friction coefficients for gases

    Science.gov (United States)

    Taylor, M. F.

    1969-01-01

    Empirical relations are used for correlating laminar and turbulent friction coefficients for gases, with large variations in the physical properties, flowing through smooth tubes. These relations have been used to correlate friction coefficients for hydrogen, helium, nitrogen, carbon dioxide and air.

  7. A gain-coefficient switched Alexandrite laser

    International Nuclear Information System (INIS)

    Lee, Chris J; Van der Slot, Peter J M; Boller, Klaus-J

    2013-01-01

    We report on a gain-coefficient switched Alexandrite laser. An electro-optic modulator is used to switch between high and low gain states by making use of the polarization dependent gain of Alexandrite. In gain-coefficient switched mode, the laser produces 85 ns pulses with a pulse energy of 240 mJ at a repetition rate of 5 Hz.

  8. Helioseismic Solar Cycle Changes and Splitting Coefficients

    Indian Academy of Sciences (India)

    tribpo

    Abstract. Using the GONG data for a period over four years, we have studied the variation of frequencies and splitting coefficients with solar cycle. Frequencies and even-order coefficients are found to change signi- ficantly with rising phase of the solar cycle. We also find temporal varia- tions in the rotation rate near the solar ...

  9. Implications of NGA for NEHRP site coefficients

    Science.gov (United States)

    Borcherdt, Roger D.

    2012-01-01

    Three proposals are provided to update tables 11.4-1 and 11.4-2 of Minimum Design Loads for Buildings and Other Structures (7-10), by the American Society of Civil Engineers (2010) (ASCE/SEI 7-10), with site coefficients implied directly by NGA (Next Generation Attenuation) ground motion prediction equations (GMPEs). Proposals include a recommendation to use straight-line interpolation to infer site coefficients at intermediate values of ̅vs (average shear velocity). Site coefficients are recommended to ensure consistency with ASCE/SEI 7-10 MCER (Maximum Considered Earthquake) seismic-design maps and simplified site-specific design spectra procedures requiring site classes with associated tabulated site coefficients and a reference site class with unity site coefficients. Recommended site coefficients are confirmed by independent observations of average site amplification coefficients inferred with respect to an average ground condition consistent with that used for the MCER maps. The NGA coefficients recommended for consideration are implied directly by the NGA GMPEs and do not require introduction of additional models.

  10. Responses to Small Break Loss of Coolant Accidents for SMART

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Kim, Hee C.; Chang, Moon H.; Zee, Sung Q.; Kim, Si-Hwan; Lee, Un-Chul

    2004-01-01

    The SMART NSSS adopts the design characteristics of containing most of the primary circuit components, such as the reactor core, main coolant pumps (MCPs), steam generators (SGs), and N 2 gas pressurizer (PZR) in a single leak-tight Reactor Pressure Vessel (RPV) with a relatively large ratio of the primary coolant inventory to the core power compared to the conventional loop-type PWR. Due to these design characteristics, the SMART can fundamentally eliminate the possibility of Large Break Loss of Coolant Accidents (LBLOCAs), improve the natural circulation capability, and assure a sufficient time to mitigate the possibility of core uncover. Also, SMART adopts inherent safety improving features and passive engineered safety systems such as the substantially large negative moderator temperature coefficients, passive residual heat removal system, emergency core cooling system, and a steel-made leak-tight Safeguard Vessel (SV) housing the RPV. This paper presents the results of the safety analyses using a MARS/SMR code for the instantaneous guillotine ruptures of the major pipelines penetrating the RPV. The analysis results, employing conservative initial/boundary conditions and assumptions, show that the safety systems of the SMART basic design adequately remove the core decay heat without causing core uncover for all the cases of the Small Break Loss of Coolant Accidents (SBLOCAs). The sensitivity study results with variable SV conditions show that the reduced SV net free volume can shorten the time for reaching the thermal and mechanical equilibrium condition between the RPV and SV. Under these boundary conditions, the primary system inventory loss can be minimized and the core remains covered for a longer period of time without any makeup of the coolant. (authors)

  11. Gini coefficient as a life table function

    Directory of Open Access Journals (Sweden)

    2003-06-01

    Full Text Available This paper presents a toolkit for measuring and analyzing inter-individual inequality in length of life by Gini coefficient. Gini coefficient and four other inequality measures are defined on the length-of-life distribution. Properties of these measures and their empirical testing on mortality data suggest a possibility for different judgements about the direction of changes in the degree of inequality by using different measures. A new computational procedure for the estimation of Gini coefficient from life tables is developed and tested on about four hundred real life tables. The estimates of Gini coefficient are precise enough even for abridged life tables with the final age group of 85+. New formulae have been developed for the decomposition of differences between Gini coefficients by age and cause of death. A new method for decomposition of age-components into effects of mortality and composition of population by group is developed. Temporal changes in the effects of elimination of causes of death on Gini coefficient are analyzed. Numerous empirical examples show: Lorenz curves for Sweden, Russia and Bangladesh in 1995, proportional changes in Gini coefficient and four other measures of inequality for the USA in 1950-1995 and for Russia in 1959-2000. Further shown are errors of estimates of Gini coefficient when computed from various types of mortality data of France, Japan, Sweden and the USA in 1900-95, decompositions of the USA-UK difference in life expectancies and Gini coefficients by age and cause of death in 1997. As well, effects of elimination of major causes of death in the UK in 1951-96 on Gini coefficient, age-specific effects of mortality and educational composition of the Russian population on changes in life expectancy and Gini coefficient between 1979 and 1989. Illustrated as well are variations in life expectancy and Gini coefficient across 32 countries in 1996-1999 and associated changes in life expectancy and Gini

  12. Pressure Sores

    Science.gov (United States)

    Pressure sores are areas of damaged skin caused by staying in one position for too long. They commonly ... wheelchair, or are unable to change your position. Pressure sores can cause serious infections, some of which are ...

  13. Modeling the Design Flow Coefficient of a Centrifugal Compressor Impeller

    Directory of Open Access Journals (Sweden)

    A. A. Drozdov

    2017-01-01

    Full Text Available In calculating gas-dynamic characteristics by the universal modeling method it is necessary to determine a non-incidence flow rate through the blades of an impeller because of its relationship with the magnitude of incidence losses. The flow area decreased by the blades of finite thickness and the blades load have impact on the critical streamline direction. The universal modeling method in primary designing uses for this a scheme of replacing the influence of the blade load by the vortex effect with identical circulation. Finally, calculating the inviscid flow around the blades allows selecting a value of the inlet blade angle. For impellers with small design flow coefficients, the condition of the non-incidence inlet for the primary design and for the calculation of the inviscid flow is significantly different. The calculating correctness of the non-incidence regime for the non-viscous flow was checked earlier by measurements of the flow in the impellers. The paper presents CFD calculations of twenty impellers in a tenfold range of design flow coefficients. To provide correct comparison, it takes into account the differences in the value of the loading factor calculated by the programs of inviscid quasi-three-dimensional calculation and CFD programs. Shows the identity of inlet conditions for both methods. To increase primary design accuracy, the calculation model was refined. The formula for calculating vortex-induced velocity involves an empirical coefficient. The analysis of data for 32 impellers with different blade profiling allowed working out formulas for calculating empirical coefficient, depending on the type of an impeller, the blade load and the width of the throat at an impeller inlet. The new scheme-based calculation with the empirical coefficient is accurate enough for the primary design.

  14. Determination of the surface drag coefficient

    DEFF Research Database (Denmark)

    Mahrt, L.; Vickers, D.; Sun, J.L.

    2001-01-01

    This study examines the dependence of the surface drag coefficient on stability, wind speed, mesoscale modulation of the turbulent flux and method of calculation of the drag coefficient. Data sets over grassland, sparse grass, heather and two forest sites are analyzed. For significantly unstable...... conditions, the drag coefficient does not depend systematically on z/L but decreases with wind speed for fixed intervals of z/L, where L is the Obukhov length. Even though the drag coefficient for weak wind conditions is sensitive to the exact method of calculation and choice of averaging time, the decrease...... of the drag coefficient with wind speed occurs for all of the calculation methods. A classification of flux calculation methods is constructed, which unifies the most common previous approaches. The roughness length corresponding to the usual Monin-Obukhov stability functions decreases with increasing wind...

  15. Diffusion coefficients of paracetamol in aqueous solutions

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Barros, Marisa C.F.; Veríssimo, Luís M.P.; Santos, Cecilia I.A.V.; Cabral, Ana M.T.D.P.V.; Gaspar, Gualter D.; Esteso, Miguel A.

    2012-01-01

    Highlights: ► Mutual diffusion coefficients of paracetamol in aqueous dilute solutions. ► Influence of the thermodynamic factors on the variation of their mutual diffusion coefficients. ► Estimation of the mutual limiting diffusion coefficients of the molecular, D m 0 , and ionized forms, D ± 0 , of this drug. - Abstract: Binary mutual diffusion coefficients measured by the Taylor dispersion method, for aqueous solutions of paracetamol (PA) at concentrations from (0.001 to 0.050) mol·dm −3 at T = 298.15 K, are reported. From the Nernst–Hartley equation and our experimental results, the limiting diffusion coefficient of this drug and its thermodynamic factors are estimated, thereby contributing in this way to a better understanding of the structure of such systems and of their thermodynamic behaviour in aqueous solution at different concentrations.

  16. Estimation of the simple correlation coefficient.

    Science.gov (United States)

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  17. CHARACTERIZATION OF RENAL BLOOD FLOW REGULATION BASED ON WAVELET COEFFICIENTS

    DEFF Research Database (Denmark)

    Pavlov, A.N.; Pavlova, O.N.; Mosekilde, Erik

    2010-01-01

    The purpose of this study is to demonstrate the possibility of revealing new characteristic features of renal blood flow autoregulation in healthy and pathological states through the application of discrete wavelet transforms to experimental time series for normotensive and hypertensive rats....... A reduction in the variability of the wavelet coefficients in hypertension is observed at both the microscopic level of the blood flow in efferent arterioles of individual nephrons and at the macroscopic level of the blood pressure in the main arteries. The reduction is manifest in both of the main frequency...

  18. Intracranial Pressure

    DEFF Research Database (Denmark)

    Hvedstrup, Jeppe; Radojicic, Aleksandra; Moudrous, Walid

    2018-01-01

    OBJECTIVE: To compare a new method of noninvasive intracranial pressure (nICP) measurement with conventional lumbar puncture (LP) opening pressure. METHODS: In a prospective multicenter study, patients undergoing LP for diagnostic purposes underwent intracranial pressure measurements with HeadSen...

  19. Pressure Ulcers

    OpenAIRE

    Monfre, Jill M.

    2016-01-01

    Unrelieved pressure or friction of the skin, particularly over bony prominences, can lead to pressure ulcers, which affect up to one third of people in hospitals or community care, and one fifth of nursing home residents. Pressure ulcers are more likely in people with reduced mobility and poor skin condition, such as older people or those with vascular disease.

  20. A low-dimensional tool for predicting force decomposition coefficients for varying inflow conditions

    KAUST Repository

    Ghommem, Mehdi; Akhtar, Imran; Hajj, M. R.

    2013-01-01

    We develop a low-dimensional tool to predict the effects of unsteadiness in the inflow on force coefficients acting on a circular cylinder using proper orthogonal decomposition (POD) modes from steady flow simulations. The approach is based on combining POD and linear stochastic estimator (LSE) techniques. We use POD to derive a reduced-order model (ROM) to reconstruct the velocity field. To overcome the difficulty of developing a ROM using Poisson's equation, we relate the pressure field to the velocity field through a mapping function based on LSE. The use of this approach to derive force decomposition coefficients (FDCs) under unsteady mean flow from basis functions of the steady flow is illustrated. For both steady and unsteady cases, the final outcome is a representation of the lift and drag coefficients in terms of velocity and pressure temporal coefficients. Such a representation could serve as the basis for implementing control strategies or conducting uncertainty quantification. Copyright © 2013 Inderscience Enterprises Ltd.