  1. Hot-isostatic pressing (HIP). Pt. 2

    International Nuclear Information System (INIS)

    Bayer, E.; Moser, G.; Seilstorfer, H.

    1981-01-01

    After the description of the microstructure and strengthening mechanism of nickel- and cobalt-base superalloys, claims for the production of suitable powders for the HIP-technology are pointed out and methods to its realization are discussed. Taking the manufacture of turbine discs (ultrasonic form) as an example the possibilities of the near-net-shape-technology are shown. Investigations on mechanical properties and on microstructures are carried out to determine the effect of HIP-process-parameters on these features. (orig.) [de

  2. Bibliography on Hot Isostatic Pressing (HIP) Technology

    Science.gov (United States)

    1992-11-01

    Nimonic API, Rene’ 77 2. MA753, IN-853 7 3. C-103,WC-103 4. Alloy 454, PWA 1480 5. Mar- M250 , Maraging (250) 6. Rene 150, PA 101 (low C) 7. Inconel 718...Pressure Welding Parameters Bryant. W. A. Weld J 54 (12), 433-S-435-S, 1975 ( AD-DI02 316 Key Words: AISI 4340. MAR- M250 . AISI 1020, 9Ni-4Co steel. Inconel...creep rupture. hot corrosion, oxidation, grain size, thermomechanical treatment MAR- M250 1. Microstructures and Mechanical Properties of HIP

  3. Hot Isostatic Press (HIP) vitrification of radwaste concretes

    International Nuclear Information System (INIS)

    Siemer, D.D.; Scheetz, B.; Gougar, M.L.D.

    1995-01-01

    Properly formulated and properly ''canned'' radwaste concretes can be readily hot-isostatically-pressed (HIPed) into materials that exhibit performance equivalent to typical radwaste-type glasses. The HIPing conditions (temperature/pressure) required to turn a concrete waste form into a ''vitrified'' waste form are quite mild and therefore consistent with both safety and high productivity. This paper describes the process and its products with reference to its potential application to Idaho Chemical Processing Plant (ICPP) reprocessing wastes

  4. No Correlation Between Press Ganey Survey Responses and Outcomes in Post-Total Hip Arthroplasty Patients.

    Science.gov (United States)

    Chughtai, Morad; Gwam, Chukwuweike U; Khlopas, Anton; Sodhi, Nipun; Delanois, Ronald E; Spindler, Kurt P; Mont, Michael A

    2018-03-01

    In the era of the online orthopedic market, patients tend to equate publicly available online satisfaction surveys with what they presume their ultimate surgical outcome will be. Therefore, the purpose of this study was to assess whether there is a correlation between Press Ganey (PG) scores and (1) Hip Western Ontario and McMaster Universities Osteoarthritis Index and Harris Hip Score; (2) Short Form-12 and Short Form-36 scores; (3) University of California Los Angeles and Visual Analog Scale scores assessed at a mean of 3 years (range, 1 to 6 years) after surgery. In addition, we assessed whether (4) these correlations persist in patients who were evaluated under 2 years and 3 or more years after surgery. Six-hundred ninety-two patients from November 2009 to January 2015 were identified from our institutional PG database. One-hundred ninety (27%) responded to the survey. One-hundred forty-nine (78%) patients were given the total hip arthroplasty assessment tools at a minimum of 2-year follow-up, and 33 patients (17%) completed their survey before 2 years after surgery. We assessed whether overall hospital rating scores correlated with the above assessment tools. Pearson correlation analysis revealed no correlation between the PG survey score and the assessment tools. HHS had the highest correlation coefficient (r = .120; P = .316); however, this was not significant. After removing the patients who had their follow-up survey administered under 2 years after surgery (33 patients), there was still no statistically significant correlation between the above-mentioned outcome scores and PG overall hospital rating (P > .05). No statistically significant relationship was found between commonly used total hip arthroplasty assessment tools and the PG overall hospital rating. Based on these results, PG surveys may not be a suitable implementation of the Center for Medicare and Medicaid services. A set of measures that can be widely collected and reported by hospitals for

  5. Optimizing the Synthesis of Alumina Inserts Using Hot Isostatic Pressing (HIP)

    Science.gov (United States)

    Ariff, T. F.; Azhar, A. Z.; Sariff, M. N.; Rasid, S. N.; Zahari, S. Z.; Bahar, R.; Karim, M.; Nurul Amin, AKM

    2018-01-01

    Alumina or Aluminium Oxide (Al2O3) is well known for its high strength and hardness. Its low heat retention and low specific heat characteristics make it attractive to be used widely as a cutting tool for grinding, milling and turning processes. Various synthesis methods have been used for the purpose of enhancing the properties of the alumina inserts. However, the optimization process using Hot Isostatic Pressing (HIP) has not been performed. This research aims in finding the optimum parameters in synthesizing the alumina inserts (98Al2O3 1.6ZrO2 0.4MgO, 93Al2O3 6.4ZrO2 0.6MgO and 85Al2O3 14.5ZrO2 0.5MgO) using HIP at different temperatures (1200, 1250 and 1300°C) and sintering time (10, 30 and 60 minutes). Hardness, density, shrinkage and microstructure using SEM were analysed. The optimum sintering condition for the alumina insert was found in 98Al2O3 1.6ZrO2 0.4MgO sintered at 1300°C for 60 minutes for it exhibited the highest values of hardness (1917HV), density (3.95g/cm3), shrinkage (9.6%).

  6. Mathematical modelling of wet paper pressing

    NARCIS (Netherlands)

    Bežanovic, D.

    2005-01-01

    The aim of this project is to reduce energy costs in paper production by optimising the process in the press section of a paper machine. In this press section water is squeezed as it passes through the press nip. In a modern press section the moisture content of the sheet after three or four presses

  7. Atlas of hot isostatic beryllium powder pressing diagrams

    International Nuclear Information System (INIS)

    Stoev, P.I.; Papirov, I.I.; Tikhinskij, G.F.; Vasil'ev, A.A.

    1995-01-01

    Diagrams of hot isotopic pressing (HIP) of beryllium powder with different grain size in a wide range of pressing parameters are built by mathematical modeling methods. The HIP diagrams presented are divided into 3 groups: parametric dependencies D=f(P,T); technological HIP diagrams; compacting mechanisms. The created data bank permits to optimise beryllium powder HIP with changing parameters. 4 refs., 23 figs

  8. Sintering of ZrC by hot isostatic pressing (HIP) and spark plasma sintering (SPS). Effect of impurities

    International Nuclear Information System (INIS)

    Allemand, Alexandre; Le Flem - Dormeval, Marion; Guillard, Francois

    2005-01-01

    Carbides are generally used as structural materials for high temperature applications. Particularly, ZrC because of low activation, neutronic transparency, cubic structure (isotropic behaviour) and good thermal conductivity, is one of the candidates under consideration for structural materials in the core of new high temperature nuclear reactors (Generation IV). Just a few studies about densification of monolithic ZrC exist. They mainly involve natural sintering or hot pressing at high temperature (until 2700 deg. C). Unfortunately those processes induce grain growth and do not lead to fully densified ZrC. The aim of this study is to compare the characteristics and the properties of ZrC sintered by HIP and by SPS. Fully dense ZrC can be reached either by HIP or by SPS, grain size being more or less controlled. Microstructural observations and mechanical testing of several ZrC grades shows that powder impurities play an important role in the quality of the grain boundaries and consequently in the mechanical properties. In particular, the porosity falls from 17% to 3 % just by reducing the free carbon content in starting ZrC powder. The densification process of dense monolithic ZrC was improved by combining a HIP at 1600 deg. C (titanium canning) followed by a post-HIP at 1900 deg. C (no canning required). Four-point bending tests are in progress to confirm the improvement of fracture strength. (authors)

  9. Pore annihilation in a single-crystal nickel-base superalloy during hot isostatic pressing: Experiment and modelling

    International Nuclear Information System (INIS)

    Epishin, Alexander; Fedelich, Bernard; Link, Thomas; Feldmann, Titus; Svetlov, Igor L.

    2013-01-01

    Pore annihilation during hot isostatic pressing (HIP) was investigated in the single-crystal nickel-base superalloy CMSX-4 experimentally by interrupted HIP tests at 1288 °C/103 MPa. The kinetics of pore annihilation was determined by density measurement and quantitative metallography. Transmission electron microscopy of a HIPed specimen showed that the pores shrink via dislocation movement on octahedral glide planes. Theoretically pore closure under HIP condition was modelled by the finite element method using crystal plasticity and large strain theories. The modelling gives a similar kinetics of pore annihilation as observed experimentally, however somewhat higher annihilation rate

  10. Hip morphology predicts posterior hip impingement in a cadaveric model.

    Science.gov (United States)

    Morris, William Z; Fowers, Cody A; Weinberg, Douglas S; Millis, Michael B; Tu, Leigh-Anne; Liu, Raymond W

    2018-05-01

    Posterior hip impingement is a recently-identified cause of hip pain. The purpose of this study is to characterise posterior femoroacetabular and ischiofemoral impingement and identify its predisposing morphologic traits. Two hundred and six cadaveric hips were randomly selected and taken through controlled motion in two pure axes associated with posterior hip impingement: external rotation (through the mechanical axis) and adduction (coronal plane). The range of motion and location of impingement was noted for each specimen. Morphologic traits including femoral/acetabular version, and true neck-shaft angle (TNSA) were also measured. External rotation impingement occurred between the femoral neck and acetabulum in 83.0% of hips, and between the lesser trochanter and ischial tuberosity in 17.0%. Adduction impingement occurred between the lesser trochanter and ischial tuberosity in 78.6% of hips, and between the femoral neck and acetabulum in 21.4%. Multiple regression revealed that increased femoral/acetabular version predicted earlier external rotation and adduction impingement. Unstandardised betas ranging from -0.39 to -0.64 reflect that each degree of increased femoral/acetabular version individually accounts for a loss of external rotation or adduction of approximately half a degree before impingement ( p < 0.001 for each). Increased TNSA was associated with earlier adduction impingement only (unstandardised beta -0.35, p = 0.005). Relative femoral/acetabular anteversion was associated with earlier posterior hip impingement. Coxa valga was associated with earlier adduction impingement, but protective against external rotation impingement. These findings highlight the importance of monitoring correction during femoral/acetabular osteotomies, as overcorrection of retroversion may predispose to earlier posterior impingement.

  11. The feasibility of bonding aluminum alloy 6061 via hot isostatic pressing (HIP)/rolling

    International Nuclear Information System (INIS)

    Fenolietto, R.A.

    1991-01-01

    The advantage of developing a HIP bonding process for dispersion fuel plates is that applying a thin cladding in a more uniform manner could allow the upper limit for LEU U 3 Si-Al dispersion fuel plate densities to be overcome. Since much less mechanical deformation would be required, the existing process limitations on the density could be removed, theoretically allowing more fuel to be added. These increases are, of course, subject to irradiation behavior of the higher loadings which is not addressed in this paper. Initial results indicate that aluminum Alloy 6061 can be successfully bonded by seal welding via electron beam (EB), HIPping, and finishing with a limited amount of rolling. (orig.)

  12. Simulation Model of Automated Peat Briquetting Press Drive

    Directory of Open Access Journals (Sweden)

    A. A. Marozka

    2012-01-01

    Full Text Available The paper presents the developed fully functional simulation model of an automated peat briquetting press drive. The given model makes it possible to reduce financial and time costs while developing, designing and operating a double-stamp peat briquetting press drive.

  13. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Zilkens C

    2011-03-01

    Full Text Available Abstract The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA. One hundred 'and one (94.4% acetabular components did not show significant migration of more than 1 mm. Six (5.6% implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.

  14. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty: a prospective cohort study.

    Directory of Open Access Journals (Sweden)

    Bente Holm

    Full Text Available By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA, post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.Firstly, to quantify changes (compared to pre-operative values in hip muscle strength, leg-press power, and functional performance in the first week after THA, and secondly, to explore relationships between the muscle strength changes, and changes in hip pain, systemic inflammation, and thigh swelling.Prospective, cohort study.Convenience sample of patients receiving a THA at Copenhagen University Hospital, Hvidovre, Denmark, between March and December 2011.Thirty-five patients (65.9 ± 7.2 years undergoing THA.Hip muscle strength, leg-press power, performance-based function, and self-reported disability were determined prior to, and 2 and 8 days after, THA (Day 2 and 8, respectively. Hip pain, thigh swelling, and C-Reactive Protein were also determined.Five patients were lost to follow-up. Hip muscle strength and leg press power were substantially reduced at Day 2 (range of reductions: 41-58%, P<0.001, but less pronounced at Day 8 (range of reductions: 23-31%, P<0.017. Self-reported symptoms and function (HOOS: Pain, Symptoms, and ADL improved at Day 8 (P<0.014. Changes in hip pain, C-Reactive Protein, and thigh swelling were not related to the muscle strength and power losses.Hip muscle strength and leg-press power decreased substantially in the first week after THA - especially at Day 2 - with some recovery at Day 8. The muscle strength loss and power loss were not related to changes in hip pain, systemic inflammation, or thigh swelling. In contrast, self-reported symptoms and function improved. These data on surgery-induced changes in muscle strength may help design impairment-directed, post-operative rehabilitation to be introduced soon after surgery.ClinicalTrials.gov NCT01246674.

  15. Nonlinear friction model for servo press simulation

    Science.gov (United States)

    Ma, Ninshu; Sugitomo, Nobuhiko; Kyuno, Takunori; Tamura, Shintaro; Naka, Tetsuo

    2013-12-01

    The friction coefficient was measured under an idealized condition for a pulse servo motion. The measured friction coefficient and its changing with both sliding distance and a pulse motion showed that the friction resistance can be reduced due to the re-lubrication during unloading process of the pulse servo motion. Based on the measured friction coefficient and its changes with sliding distance and re-lubrication of oil, a nonlinear friction model was developed. Using the newly developed the nonlinear friction model, a deep draw simulation was performed and the formability was evaluated. The results were compared with experimental ones and the effectiveness was verified.

  16. Modelling of powder die compaction for press cycle optimization

    Directory of Open Access Journals (Sweden)

    Bayle Jean-Philippe

    2016-01-01

    Full Text Available A new electromechanical press for fuel pellet manufacturing was built last year in partnership between CEA-Marcoule and ChampalleAlcen. This press was developed to shape pellets in a hot cell via remote handling. It has been qualified to show its robustness and to optimize the compaction cycle, thus obtaining a better sintered pellet profile and limiting damage. We will show you how 400 annular pellets have been produced with good geometry's parameters, based on press settings management. These results are according to a good phenomenological pressing knowledge with Finite Element Modeling calculation. Therefore, during die pressing, a modification in the punch displacement sequence induces fluctuation in the axial distribution of frictional forces. The green pellet stress and density gradients are based on these frictional forces between powder and tool, and between grains in the powder, influencing the shape of the pellet after sintering. The pellet shape and diameter tolerances must be minimized to avoid the need for grinding operations. To find the best parameters for the press settings, which enable optimization, FEM calculations were used and different compaction models compared to give the best calculation/physical trial comparisons. These simulations were then used to predict the impact of different parameters when there is a change in the type of powder and the pellet size, or when the behavior of the press changes during the compaction time. In 2016, it is planned to set up the press in a glove box for UO2 manufacturing qualification based on our simulation methodology, before actual hot cell trials in the future.

  17. Geometry Modeling Program Implementation of Human Hip Tissue

    Directory of Open Access Journals (Sweden)

    WANG Mo-nan

    2017-10-01

    Full Text Available Abstract:Aiming to design a simulate software of human tissue modeling and analysis,Visual Studio 2010 is selected as a development tool to develop a 3 D reconstruction software of human tissue with language C++.It can be used alone. It also can be a module of the virtual surgery systems. The system includes medical image segmentation modules and 3 D reconstruction modules,and can realize the model visualization. This software system has been used to reconstruct hip muscles,femur and hip bone accurately. The results show these geometry models can simulate the structure of hip tissues.

  18. Geometry Modeling Program Implementation of Human Hip Tissue

    Directory of Open Access Journals (Sweden)

    WANG Monan

    2017-04-01

    Full Text Available Aiming to design a simulate software of human tissue modeling and analysis,Visual Studio 2010 is selected as a development tool to develop a 3 D reconstruction software of human tissue with language C++.It can be used alone. It also can be a module of the virtual surgery systems. The system includes medical image segmentation modules and 3 D reconstruction modules,and can realize the model visualization. This software system has been used to reconstruct hip muscles,femur and hip bone accurately. The results show these geometry models can simulate the structure of hip tissues.

  19. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  20. EMG analysis and modelling of flat bench press using artificial ...

    African Journals Online (AJOL)

    The objective of this study was to evaluate the contribution of particular muscle groups during the Flat Bench Press (FBP) with different external loads. Additionally, the authors attempted to determine whether regression models or Artificial Neural Networks (ANNs) can predict FBP results more precisely and whether they can ...

  1. Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee

    2017-08-01

    Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.

  2. A virtual model of the bench press exercise.

    Science.gov (United States)

    Rahmani, Abderrahmane; Rambaud, Olivier; Bourdin, Muriel; Mariot, Jean-Pierre

    2009-08-07

    The objective of this study was to design and validate a three degrees of freedom model in the sagittal plane for the bench press exercise. The mechanical model was based on rigid segments connected by revolute and prismatic pairs, which enabled a kinematic approach and global force estimation. The method requires only three simple measurements: (i) horizontal position of the hand (x(0)); (ii) vertical displacement of the barbell (Z) and (iii) elbow angle (theta). Eight adult male throwers performed maximal concentric bench press exercises against different masses. The kinematic results showed that the vertical displacement of each segment and the global centre of mass followed the vertical displacement of the lifted mass. Consequently, the vertical velocity and acceleration of the combined centre of mass and the lifted mass were identical. Finally, for each lifted mass, there were no practical differences between forces calculated from the bench press model and those simultaneously measured with a force platform. The error was lower than 2.5%. The validity of the mechanical method was also highlighted by a standard error of the estimate (SEE) ranging from 2.0 to 6.6N in absolute terms, a coefficient of variation (CV) or =0.99 for all the lifts (pbench press exercises in both field and laboratory conditions.

  3. Development of manufacturing technology of radial plate in superconducting coil for fusion reactor by diffusion bonding by Hot Isostatic Pressing (HIP)

    International Nuclear Information System (INIS)

    Takano, Katsutoshi; Koizumi, Norikiyo; Masuo, Hiroshi; Natsume, Yoshihisa

    2014-01-01

    The radial plates (RPs), which is used in Toroidal field (TF) coil in ITER, are quite large, such as 13 m tall and 9 m wide, but thin, such as 10 cm thick, and are made of stainless steel. Even though they are very large structures, they require very high manufacturing tolerances and high mechanical strength at 4 K. The similar requirements will be required in the next generation fusion reactor. Therefore, the authors intend to develop efficient manufacturing methods in parallel with ITER TF coil RP manufacture. The authors therefore performed trial manufacture of the RP segments using a diffusion bonding method, namely Hot Isostatic Pressing (HIP). As a result of trials, it was clarified that even when HIPping is applied, the mechanical characteristic of base metal is not deteriorated. The machining period can be reduced by about 1/3 compared with the traditional manufacturing method. On the other hand, mechanical strength at 4 K is degraded due to weak bonding, that is no grain growth through joint, by HIPping. However, additional test indicates promising possibility of much better joint by higher temperature and joint surface treated HIPpings. These results justified that RP segment manufacturing is not only possible, but it is a technically valid manufacturing method that satisfies all requirements. (author)

  4. Planetary Suit Hip Bearing Model for Predicting Design vs. Performance

    Science.gov (United States)

    Cowley, Matthew S.; Margerum, Sarah; Harvil, Lauren; Rajulu, Sudhakar

    2011-01-01

    Designing a planetary suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. In order to verifying that new suit designs meet requirements, full prototypes must eventually be built and tested with human subjects. Using computer models early in the design phase of new hardware development can be advantageous, allowing virtual prototyping to take place. Having easily modifiable models of the suit hard sections may reduce the time it takes to make changes to the hardware designs and then to understand their impact on suit and human performance. A virtual design environment gives designers the ability to think outside the box and exhaust design possibilities before building and testing physical prototypes with human subjects. Reductions in prototyping and testing may eventually reduce development costs. This study is an attempt to develop computer models of the hard components of the suit with known physical characteristics, supplemented with human subject performance data. Objectives: The primary objective was to develop an articulating solid model of the Mark III hip bearings to be used for evaluating suit design performance of the hip joint. Methods: Solid models of a planetary prototype (Mark III) suit s hip bearings and brief section were reverse-engineered from the prototype. The performance of the models was then compared by evaluating the mobility performance differences between the nominal hardware configuration and hardware modifications. This was accomplished by gathering data from specific suited tasks. Subjects performed maximum flexion and abduction tasks while in a nominal suit bearing configuration and in three off-nominal configurations. Performance data for the hip were recorded using state-of-the-art motion capture technology. Results: The results demonstrate that solid models of planetary suit hard segments for use as a performance design tool is feasible. From a general trend perspective

  5. Finite element modelling and associated experimentations to optimize and predict the pressing cycle of a future AMBB manufacturing press

    International Nuclear Information System (INIS)

    Bayle, J.P.; Mezeix, P.; Tronche, E.; Delette, G.; Remy, E.; Picart, S.

    2014-01-01

    This study presents an approach based on the use of pellet forming numerical digital simulation which enables optimization of the die pressing cycle. Semi-empirical mechanical models were used in an FEM code, CAST3M. Specific powder characterizations were also performed to supply the mechanical parameters of compaction model. The methodology for the identification of five main coefficients (index flow, elastic and plastic parameters) was used with two different powders. The results show that the axial distribution of frictional forces may be changed during die pressing by a modification of the sequence of punch displacements. According to these results and the literature, the pressing cycle can be considered to have an influence on the shape of a sintered pellet through the axial distribution of green density. The process used for the identification of the Cam-Clay model coefficients seems to be in good agreement, even if the changes in certain parameters remain rather unclear and will require follow-up studies to confirm some of the results. The experimental device used produces good quality pellets, and the Radial Open Die Modulus remains the first choice for reduced pellet damage. Much work still remains to be done to fully define the identification process and create the most representative simulations possible before launching an industrial version of a nuclearized press, planned for the last quarter of year 2014. (authors)

  6. Characteristics of rose hip (Rosa canina L.) cold-pressed oil and its oxidative stability studied by the differential scanning calorimetry method.

    Science.gov (United States)

    Grajzer, Magdalena; Prescha, Anna; Korzonek, Katarzyna; Wojakowska, Anna; Dziadas, Mariusz; Kulma, Anna; Grajeta, Halina

    2015-12-01

    Two new commercially available high linolenic oils, pressed at low temperature from rose hip seeds, were characterised for their composition, quality and DPPH radical scavenging activity. The oxidative stability of oils was assessed using differential scanning calorimetry (DSC). Phytosterols, tocopherols and carotenoids contents were up to 6485.4; 1124.7; and 107.7 mg/kg, respectively. Phenolic compounds determined for the first time in rose hip oil totalled up to 783.55 μg/kg, with a predominant presence of p-coumaric acid methyl ester. Antiradical activity of the oils reached up to 3.00 mM/kg TEAC. The acid, peroxide and p-anisidine values as well as iron and copper contents indicated good quality of the oils. Relatively high protection against oxidative stress in the oils seemed to be a result of their high antioxidant capacity and the level of unsaturation of fatty acids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Modeling climate effects on hip fracture rate by the multivariate GARCH model in Montreal region, Canada

    Science.gov (United States)

    Modarres, Reza; Ouarda, Taha B. M. J.; Vanasse, Alain; Orzanco, Maria Gabriela; Gosselin, Pierre

    2014-07-01

    Changes in extreme meteorological variables and the demographic shift towards an older population have made it important to investigate the association of climate variables and hip fracture by advanced methods in order to determine the climate variables that most affect hip fracture incidence. The nonlinear autoregressive moving average with exogenous variable-generalized autoregressive conditional heteroscedasticity (ARMA X-GARCH) and multivariate GARCH (MGARCH) time series approaches were applied to investigate the nonlinear association between hip fracture rate in female and male patients aged 40-74 and 75+ years and climate variables in the period of 1993-2004, in Montreal, Canada. The models describe 50-56 % of daily variation in hip fracture rate and identify snow depth, air temperature, day length and air pressure as the influencing variables on the time-varying mean and variance of the hip fracture rate. The conditional covariance between climate variables and hip fracture rate is increasing exponentially, showing that the effect of climate variables on hip fracture rate is most acute when rates are high and climate conditions are at their worst. In Montreal, climate variables, particularly snow depth and air temperature, appear to be important predictors of hip fracture incidence. The association of climate variables and hip fracture does not seem to change linearly with time, but increases exponentially under harsh climate conditions. The results of this study can be used to provide an adaptive climate-related public health program and ti guide allocation of services for avoiding hip fracture risk.

  8. Preparation of amorphous-crystalline SiO{sub 2} composite by hot isostatic pressing (HIP). 2; HIP ho ni yoru SiO{sub 2} kei hishoshitsu-kesshoshitsu fukugo zairyo no sakusei. 2

    Energy Technology Data Exchange (ETDEWEB)

    Ito, S.; Nishii, J.; Fujii, T.; Akashi, K. [Science University of Tokyo, Tokyo (Japan). Faculty of Science and Tecnology

    2000-08-15

    The composites consisting of {alpha}-quartz crystallites and amorphous SiO{sub 2} were prepared by HIP technique, imitating the structure of natural agate. In the previous study, the K{sub IC} of the composite prepared from the mixed powder of crystallites and amorphous SiO{sub 2} was comparable to that of the natural agate (0.56MN/m{sup 1.5}). In this study, to increase the toughness of the composite, (1) the mixture of silica sol and {alpha}-quartz powder and (2) silica sol including nucleation promoter were examined as starting materials respectively. These starting materials were pressed into powder compacts with {phi} 10 multiplied 50mm in size. The Pyrex glass capsule containing the compact was hipped at 800-1,200 degrees C for 0-120 minutes under the pressure of 200 MPa. The K{sub IC} of the composite obtained from the mixture of silica sol and {alpha}-quartz powder was equivalent to that obtained in the previous study, while the maximum K{sub IC} (0.63 MN/m{sup 1.5}) was obtained when PbCl{sub 2} was used as a nucleation promoter. The nucleation promoter having low solubility in water was useful for the homogeneous generation of the crystallites. (author)

  9. A Simplified Model of an Offset Ram Press for Sunflower Oil ...

    African Journals Online (AJOL)

    This paper presents the theoretical analysis of a simplified model of a ram press. The design of the ram press is based on the classical slider-crank mechanism. A force analysis of the press was performed for several successive positions of the driving lever (handle) and for a range of values of certain dimensionless ...

  10. Use of DXA-Based Structural Engineering Models of the Proximal Femur to Discriminate Hip Fracture

    Science.gov (United States)

    Yang, Lang; Peel, Nicola; Clowes, Jackie A; McCloskey, Eugene V; Eastell, Richard

    2011-01-01

    Several DXA-based structural engineering models (SEMs) of the proximal femur have been developed to estimate stress caused by sideway falls. Their usefulness in discriminating hip fracture has not yet been established and we therefore evaluated these models. The hip DXA scans of 51 postmenopausal women with hip fracture (30 femoral neck, 17 trochanteric, and 4 unspecified) and 153 age-, height-, and weight-matched controls were reanalyzed using a special version of Hologic’s software that produced a pixel-by-pixel BMD map. For each map, a curved-beam, a curved composite-beam, and a finite element model were generated to calculate stress within the bone when falling sideways. An index of fracture risk (IFR) was defined over the femoral neck, trochanter, and total hip as the stress divided by the yield stress at each pixel and averaged over the regions of interest. Hip structure analysis (HSA) was also performed using Hologic APEX analysis software. Hip BMD and almost all parameters derived from HSA and SEM were discriminators of hip fracture on their own because their ORs were significantly >1. Because of the high correlation of total hip BMD to HSA and SEM-derived parameters, only the bone width discriminated hip fracture independently from total hip BMD. Judged by the area under the receiver operating characteristics curve, the trochanteric IFR derived from the finite element model was significant better than total hip BMD alone and similar to the total hip BMD plus bone width in discriminating all hip fracture and femoral neck fracture. No index was better than total hip BMD for discriminating trochanteric fractures. In conclusion, the finite element model has the potential to replace hip BMD in discriminating hip fractures. PMID:18767924

  11. Functional outcome measures in a surgical model of hip osteoarthritis in dogs

    OpenAIRE

    Little, Dianne; Johnson, Stephen; Hash, Jonathan; Olson, Steven A.; Estes, Bradley T.; Moutos, Franklin T.; Lascelles, B. Duncan X.; Guilak, Farshid

    2016-01-01

    Background The hip is one of the most common sites of osteoarthritis in the body, second only to the knee in prevalence. However, current animal models of hip osteoarthritis have not been assessed using many of the functional outcome measures used in orthopaedics, a characteristic that could increase their utility in the evaluation of therapeutic interventions. The canine hip shares similarities with the human hip, and functional outcome measures are well documented in veterinary medicine, pr...

  12. Development of a hip joint model for finite volume simulations.

    Science.gov (United States)

    Cardiff, P; Karač, A; FitzPatrick, D; Ivanković, A

    2014-01-01

    This paper establishes a procedure for numerical analysis of a hip joint using the finite volume method. Patient-specific hip joint geometry is segmented directly from computed tomography and magnetic resonance imaging datasets and the resulting bone surfaces are processed into a form suitable for volume meshing. A high resolution continuum tetrahedral mesh has been generated, where a sandwich model approach is adopted; the bones are represented as a stiffer cortical shells surrounding more flexible cancellous cores. Cartilage is included as a uniform thickness extruded layer and the effect of layer thickness is investigated. To realistically position the bones, gait analysis has been performed giving the 3D positions of the bones for the full gait cycle. Three phases of the gait cycle are examined using a finite volume based custom structural contact solver implemented in open-source software OpenFOAM.

  13. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    Science.gov (United States)

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (Pcup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. A three-dimensional finite element model for biomechanical analysis of the hip.

    Science.gov (United States)

    Chen, Guang-Xing; Yang, Liu; Li, Kai; He, Rui; Yang, Bin; Zhan, Yan; Wang, Zhi-Jun; Yu, Bing-Nin; Jian, Zhe

    2013-11-01

    The objective of this study was to construct a three-dimensional (3D) finite element model of the hip. The images of the hip were obtained from Chinese visible human dataset. The hip model includes acetabular bone, cartilage, labrum, and bone. The cartilage of femoral head was constructed using the AutoCAD and Solidworks software. The hip model was imported into ABAQUS analysis system. The contact surface of the hip joint was meshed. To verify the model, the single leg peak force was loaded, and contact area of the cartilage and labrum of the hip and pressure distribution in these structures were observed. The constructed 3D hip model reflected the real hip anatomy. Further, this model reflected biomechanical behavior similar to previous studies. In conclusion, this 3D finite element hip model avoids the disadvantages of other construction methods, such as imprecision of cartilage construction and the absence of labrum. Further, it provides basic data critical for accurately modeling normal and abnormal loads, and the effects of abnormal loads on the hip.

  15. A novel Fe–Cr–Nb matrix composite containing the TiB_2 neutron absorber synthesized by mechanical alloying and final hot isostatic pressing (HIP) in the Ti-tubing

    International Nuclear Information System (INIS)

    Litwa, Przemysław; Perkowski, Krzysztof; Zasada, Dariusz; Kobus, Izabela; Konopka, Gustaw; Czujko, Tomasz; Varin, Robert A.

    2016-01-01

    The Fe–Cr–Ti-Nb elemental powders were mechanically alloyed/ball milled with TiB_2 and a small quantity of Y_2O_3 ceramic to synthesize a novel Fe-based alloy-ceramic powder composite that could be processed by hot isostatic pressing (HIP) for a perceived potential application as a neutron absorber in nuclear reactors. After ball milling for the 30–80 h duration relatively uniform powders with micrometric sizes were produced. With increasing milling time a fraction of TiB_2 particles became covered with the much softer Fe-based alloy which resulted in the formation of a characteristic “core-mantel” structure. For the final HIP-ing process the mechanically alloyed powders were initially uniaxially pressed into rod-shaped compacts and then cold isostatically pressed (CIP-ed). Subsequently, the rod-shaped compacts were placed in the Ti-tubing and subjected to hot isostatic pressing (HIP) at 1150 °C/200 MPa pressure. The HIP-ing process resulted in the formation of the near-Ti and intermediate diffusional layers in the microstructure of HIP-ed samples which formed in accord with the Fe-Ti binary phase diagram. Those layers contain the phases such as α-Ti (HCP), the FeTi intermetallic and their hypo-eutectoid mixtures. In addition, needle-like particles were formed in both layers in accord with the Ti-B binary phase diagram. Nanohardness testing, using a Berkovich type diamond tip, shows that the nanohardness in the intermediate layer areas, corresponding to the composition of the hypo-eutectoid mixture of Ti-FeTi, equals 980.0 (±27.1) HV and correspondingly 1176.9 (±47.6) HV for the FeTi phase. The nanohardness in the sample's center in the areas with the fine mixture of Fe-based alloy and small TiB_2 particles equals 1048.3 (±201.8) HV. The average microhardness of samples HIP-ed from powders milled for 30 and 80 h is 588 HV and 733 HV, respectively. - Highlights: • A Fe–Cr–Nb-based composite with TiB_2 neutron absorbing ceramic was mechanically

  16. Prometheus payment model: application to hip and knee replacement surgery.

    Science.gov (United States)

    Rastogi, Amita; Mohr, Beth A; Williams, Jeffery O; Soobader, Mah-Jabeen; de Brantes, Francois

    2009-10-01

    The Prometheus Payment Model offers a potential solution to the failings of the current fee-for-service system and various forms of capitation. At the core of the Prometheus model are evidence-informed case rates (ECRs), which include a bundle of typical services that are informed by evidence and/or expert opinion as well as empirical data analysis, payment based on the severity of patients, and allowances for potentially avoidable complications (PACs) and other provider-specific variations in payer costs. We outline the methods and findings of the hip and knee arthroplasty ECRs with an emphasis on PACs. Of the 2076 commercially insured patients undergoing hip arthroplasty in our study, PAC costs totaled $7.8 million (14% of total costs; n = 699 index PAC stays). Similarly, PAC costs were $12.7 million (14% of total costs; n = 897 index PAC stays) for 3403 patients undergoing knee arthroplasty. By holding the providers clinically and financially responsible for PACs, and by segmenting and quantifying the type of PACs generated during and after the procedure, the Prometheus model creates an opportunity for providers to focus on the reduction of PACs, including readmissions, making the data actionable and turn the waste related to PAC costs into potential savings.

  17. A method to investigate the biomechanical alterations in Perthes’ disease by hip joint contact modeling

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Skytte, Tina Lercke; Traberg, Marie Sand

    2017-01-01

    for the preoperative planning to obtain stress relief for the highly stressed areas in the malformed hip. This single-patient study demonstrated that the biomechanical alterations in Perthes’ disease can be evaluated individually by patient-specific finite element contact modeling using MRI. A multi-patient study...... was to develop a method to investigate the biomechanical alterations in Perthes’ disease by finite element (FE ) contact modeling using MRI. The MRI data of a unilateral Perthes’ case was obtained to develop the three-dimensional FE model of the hip joint. The stress and contact pressure patterns...... in the unaffected hip were well distrib uted. Elevated concentrations of stress and contact pressure were found in the Perthes’ hip. The highest femoral cartilagev on Mises stress 3.9 MPa and contact pressure 5.3 M P a were found in the Perthes’ hip, whereas 2.4 M P a and 4.9 MP a in the healthy hip, respectively...

  18. Support for total hip replacement surgery: Structures modeling, Gait Data Analysis and Report system

    Directory of Open Access Journals (Sweden)

    Gianluca Mario Izzo

    2012-03-01

    Full Text Available For the treatment of advanced damages of hip joints, Total Hip Arthroplasty is well proven. Due to the different mechanical properties of the prosthesis material and the bone tissue, a partial unloading of the periprosthetic bone occurs. The bone cement causes reduction in bone density as a result of removal of normal stress from the bone, leading to weakening of the bone in that area and the fracture risk increases. Bone loss is identified as one of the main reasons for loosening of the stem. Otherwise, thanks to the press-fit of the non-cemented stem achieved by surgery, the bone layers immediately adjacent to the stem are preloaded, thus encouraged growing, and the bone getting stronger. The non-cemented stem would be the better choice for every patient, but the question remains if the femur can handle the press- fitting surgery. This studies aim to develop a monitoring techniques based on Gait analysis and bone density changes to assess patient recovery after Total Hip Arthroplasty. Furthermore, to validate computational processes based on 3D modeling and Finite Element Methods for optimizing decision making in the operation process and selecting the suited surgical procedure. A vision could be minimizing risk of periprosthetic fracture during and after surgery. Patients: The sample presents 11 patients receiving cemented implant and 13 for the uncemented. Patients are grouped by type of implant. Three checkpoints were considered: before, after operation and one year later. CT scans, gaitrite and kinepro measurements have been realized. Main outcome measures: Fracture risk probability is higher in bone with low bone mineral density; therefore bones are more fragile in elderly people. BMD is indeed one parameter considered among all the observations. Periprosthetic fracture of the femur is a rare but complex complication of THA, and requires demanding surgery. As such, they result in considerable morbidity and dysfunction. Thus, tests of

  19. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.

    Science.gov (United States)

    Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J

    2018-04-03

    The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.

  20. Using a finite element pediatric hip model in clinical 2 evaluation - a feasibility study

    DEFF Research Database (Denmark)

    Skytte, T. L.; Mikkelsen, Lars Pilgaard; Sonne-Holm, Stig

    2017-01-01

    The paper describe a method to construct a finite element model of the hip joint of a child based on clinical recorded CT data. A model which can be used for diagnostic aid and pre-operative surgical evaluation. First part of this development is a feasibility study of this method. A scan...... to previous published experimental studies and computational models investigating the adult hip joint. Good correlation between the current model and previous models were found. The current case specific modeling technique may be a useful complement to the previously developed hip models....

  1. Modelling and Simulation Based on Matlab/Simulink: A Press Mechanism

    International Nuclear Information System (INIS)

    Halicioglu, R; Dulger, L C; Bozdana, A T

    2014-01-01

    In this study, design and kinematic analysis of a crank-slider mechanism for a crank press is studied. The crank-slider mechanism is the commonly applied one as direct and indirect drive alternatives in practice. Since inexpensiveness, flexibility and controllability are getting more and more important in many industrial applications especially in automotive industry, a crank press with servo actuator (servo crank press) is taken as an application. Design and kinematic analysis of representative mechanism is presented with geometrical analysis for the inverse kinematic of the mechanism by using desired motion concept of slider. The mechanism is modelled in MATLAB/Simulink platform. The simulation results are presented herein

  2. Modelling and Simulation Based on Matlab/Simulink: A Press Mechanism

    Science.gov (United States)

    Halicioglu, R.; Dulger, L. C.; Bozdana, A. T.

    2014-03-01

    In this study, design and kinematic analysis of a crank-slider mechanism for a crank press is studied. The crank-slider mechanism is the commonly applied one as direct and indirect drive alternatives in practice. Since inexpensiveness, flexibility and controllability are getting more and more important in many industrial applications especially in automotive industry, a crank press with servo actuator (servo crank press) is taken as an application. Design and kinematic analysis of representative mechanism is presented with geometrical analysis for the inverse kinematic of the mechanism by using desired motion concept of slider. The mechanism is modelled in MATLAB/Simulink platform. The simulation results are presented herein.

  3. A model-based approach to stabilizing crutch supported paraplegic standing by artificial hip joint stiffness.

    Science.gov (United States)

    van der Spek, Jaap H; Veltink, Peter H; Hermens, Hermie J; Koopman, Bart F J M; Boom, Herman B K

    2003-12-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N x m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur.

  4. A novel Fe–Cr–Nb matrix composite containing the TiB{sub 2} neutron absorber synthesized by mechanical alloying and final hot isostatic pressing (HIP) in the Ti-tubing

    Energy Technology Data Exchange (ETDEWEB)

    Litwa, Przemysław [Department of Advanced Materials and Technologies, Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland); Perkowski, Krzysztof [Department of Nanotechnology, Institute of Ceramics and Building Materials, Postępu 9, 02-676 Warsaw (Poland); Zasada, Dariusz [Department of Advanced Materials and Technologies, Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland); Kobus, Izabela; Konopka, Gustaw [Department of Nanotechnology, Institute of Ceramics and Building Materials, Postępu 9, 02-676 Warsaw (Poland); Czujko, Tomasz [Department of Advanced Materials and Technologies, Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland); Varin, Robert A., E-mail: robert.varin@uwaterloo.ca [Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Ave., Waterloo, ON N2L 3G1 (Canada)

    2016-07-25

    The Fe–Cr–Ti-Nb elemental powders were mechanically alloyed/ball milled with TiB{sub 2} and a small quantity of Y{sub 2}O{sub 3} ceramic to synthesize a novel Fe-based alloy-ceramic powder composite that could be processed by hot isostatic pressing (HIP) for a perceived potential application as a neutron absorber in nuclear reactors. After ball milling for the 30–80 h duration relatively uniform powders with micrometric sizes were produced. With increasing milling time a fraction of TiB{sub 2} particles became covered with the much softer Fe-based alloy which resulted in the formation of a characteristic “core-mantel” structure. For the final HIP-ing process the mechanically alloyed powders were initially uniaxially pressed into rod-shaped compacts and then cold isostatically pressed (CIP-ed). Subsequently, the rod-shaped compacts were placed in the Ti-tubing and subjected to hot isostatic pressing (HIP) at 1150 °C/200 MPa pressure. The HIP-ing process resulted in the formation of the near-Ti and intermediate diffusional layers in the microstructure of HIP-ed samples which formed in accord with the Fe-Ti binary phase diagram. Those layers contain the phases such as α-Ti (HCP), the FeTi intermetallic and their hypo-eutectoid mixtures. In addition, needle-like particles were formed in both layers in accord with the Ti-B binary phase diagram. Nanohardness testing, using a Berkovich type diamond tip, shows that the nanohardness in the intermediate layer areas, corresponding to the composition of the hypo-eutectoid mixture of Ti-FeTi, equals 980.0 (±27.1) HV and correspondingly 1176.9 (±47.6) HV for the FeTi phase. The nanohardness in the sample's center in the areas with the fine mixture of Fe-based alloy and small TiB{sub 2} particles equals 1048.3 (±201.8) HV. The average microhardness of samples HIP-ed from powders milled for 30 and 80 h is 588 HV and 733 HV, respectively. - Highlights: • A Fe–Cr–Nb-based composite with TiB{sub 2} neutron

  5. Specimen-specific modeling of hip fracture pattern and repair.

    Science.gov (United States)

    Ali, Azhar A; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H; Rullkoetter, Paul J; Laz, Peter J

    2014-01-22

    Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. © 2013 Published by Elsevier Ltd.

  6. Functional outcome measures in a surgical model of hip osteoarthritis in dogs.

    Science.gov (United States)

    Little, Dianne; Johnson, Stephen; Hash, Jonathan; Olson, Steven A; Estes, Bradley T; Moutos, Franklin T; Lascelles, B Duncan X; Guilak, Farshid

    2016-12-01

    The hip is one of the most common sites of osteoarthritis in the body, second only to the knee in prevalence. However, current animal models of hip osteoarthritis have not been assessed using many of the functional outcome measures used in orthopaedics, a characteristic that could increase their utility in the evaluation of therapeutic interventions. The canine hip shares similarities with the human hip, and functional outcome measures are well documented in veterinary medicine, providing a baseline for pre-clinical evaluation of therapeutic strategies for the treatment of hip osteoarthritis. The purpose of this study was to evaluate a surgical model of hip osteoarthritis in a large laboratory animal model and to evaluate functional and end-point outcome measures. Seven dogs were subjected to partial surgical debridement of cartilage from one femoral head. Pre- and postoperative pain and functional scores, gait analysis, radiographs, accelerometry, goniometry and limb circumference were evaluated through a 20-week recovery period, followed by histological evaluation of cartilage and synovium. Animals developed histological and radiographic evidence of osteoarthritis, which was correlated with measurable functional impairment. For example, Mankin scores in operated limbs were positively correlated to radiographic scores but negatively correlated to range of motion, limb circumference and 20-week peak vertical force. This study demonstrates that multiple relevant functional outcome measures can be used successfully in a large laboratory animal model of hip osteoarthritis. These measures could be used to evaluate relative efficacy of therapeutic interventions relevant to human clinical care.

  7. Biomechanical Evaluations of Hip Fracture Using Finite Element Model that Models Individual Differences of Femur

    OpenAIRE

    田中, 英一; TANAKA, Eiichi; 山本, 創太; YAMAMOTO, Sota; 坂本, 誠二; SAKAMOTO, Seiji; 中西, 孝文; NAKANISHI, Takafumi; 原田, 敦; HARADA, Atsushi; 水野, 雅士; MIZUNO, Masashi

    2004-01-01

    This paper is concerned with an individual finite element modeling system for femur and biomechanical evaluations of the influences of loading conditions, bone shape and bone density on risks of hip fracture. Firstly, a method to construct an individual finite element model by morphological parameters that represent femoral shapes was developed. Using the models with different shapes constructed by this method, the effects of fall direction, posture of upper body, femur shape and bone density...

  8. Fabrication of Polycrystalline Transparent Co+2: MgAl2O4 by a Combination of Spark Plasma Sintering (SPS and Hot Isostatic Pressing (HIP Processes

    Directory of Open Access Journals (Sweden)

    Sokol Maxim

    2017-01-01

    Full Text Available Transparent Co2+ doped MgAl2Ob4 spinel was fabricated by SPS consolidation followed by and HIP treatment. It was established that HIP treatment significantly improved transparency of the ceramic in a wide range of wavelengths, especially, in a range, which is relevant for Q-switching. Nonlinear absorption was demonstrated and the ground and excited state absorption cross sections were estimated. The positive effect of the HIP treatment on the optical properties is related to an elimination of extremely fine porosity and to the location of Co ions at Mg2+sites in the spinel ionic structure. The experimental results indicate that the fabricated specimens can be used as a passive laser Q-switching material.

  9. Tensile ductility of an AlCoCrFeNi multi-phase high-entropy alloy through hot isostatic pressing (HIP) and homogenization

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Zhi, E-mail: Zhi.Tang@alcoa.com [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States); Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA 24061 (United States); Senkov, Oleg N. [Air Force Research Laboratory, Materials and Manufacturing Directorate, Wright-Patterson Air Force Base, OH 45433 (United States); Parish, Chad M. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Zhang, Chuan; Zhang, Fan [CompuTherm LLC, 437 S. Yellowstone Dr., Suite 217, Madison, WI 53719 (United States); Santodonato, Louis J. [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States); Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wang, Gongyao [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States); Zhao, Guangfeng; Yang, Fuqian [Department of Chemical and Materials Engineering, University of Kentucky, Lexington, KY 40506 (United States); Liaw, Peter K., E-mail: pliaw@utk.edu [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States)

    2015-10-28

    The microstructure and phase composition of an AlCoCrFeNi high-entropy alloy (HEA) were studied in as-cast (AlCoCrFeNi-AC, AC represents as-cast) and homogenized (AlCoCrFeNi-HP, HP signifies hot isostatic pressed and homogenized) conditions. The AlCoCrFeNi-AC ally has a dendritric structure in the consisting primarily of a nano-lamellar mixture of A2 (disordered body-centered-cubic (BCC)) and B2 (ordered BCC) phases, formed by an eutectic reaction. The homogenization heat treatment, consisting of hot isostatic pressed for 1 h at 1100 °C, 207 MPa and annealing at 1150 °C for 50 h, resulted in an increase in the volume fraction of the A1 phase and formation of a Sigma (σ) phase. Tensile properties in as-cast and homogenized conditions are reported at 700 °C. The ultimate tensile strength was virtually unaffected by heat treatment, and was 396±4 MPa at 700 °C. However, homogenization produced a noticeable increase in ductility. The AlCoCrFeNi-AC alloy showed a tensile elongation of only 1.0%, while after the heat-treatment, the elongation of AlCoCrFeNi-HP was 11.7%. Thermodynamic modeling of non-equilibrium and equilibrium phase diagrams for the AlCoCrFeNi HEA gave good agreement with the experimental observations of the phase contents in the AlCoCrFeNi-AC and AlCoCrFeNi-HP. The reasons for the improvement of ductility after the heat treatment and the crack initiation subjected to tensile loading were discussed.

  10. Dynamic modeling and experiment of a new type of parallel servo press considering gravity counterbalance

    Science.gov (United States)

    He, Jun; Gao, Feng; Bai, Yongjun; Wu, Shengfu

    2013-11-01

    The large capacity servo press is traditionally realized by means of redundant actuation, however there exist the over-constraint problem and interference among actuators, which increases the control difficulty and the product cost. A new type of press mechanism with parallel topology is presented to develop the mechanical servo press with high stamping capacity. The dynamic model considering gravity counterbalance is proposed based on the virtual work principle, and then the effect of counterbalance cylinder on the dynamic performance of the servo press is studied. It is found that the motor torque required to operate the press is a lot less than the others when the ratio of the counterbalance force to the gravity of ram is in the vicinity of 1.0. The stamping force of the real press prototype can reach up to 25 MN on the position of 13 mm away from the bottom dead center. The typical deep-drawing process with 1 200 mm stroke at 8 strokes per minute is proposed by means of five order polynomial. On this process condition, the driving torques are calculated based on the above dynamic model and the torque measuring test is also carried out on the prototype. It is shown that the curve trend of calculation torque is consistent to the measured result and that the average error is less than 15%. The parallel mechanism is introduced into the development of large capacity servo press to avoid the over-constraint and interference of traditional redundant actuation, and its dynamic characteristics with gravity counterbalance are presented.

  11. PRESS-based EFOR algorithm for the dynamic parametrical modeling of nonlinear MDOF systems

    Science.gov (United States)

    Liu, Haopeng; Zhu, Yunpeng; Luo, Zhong; Han, Qingkai

    2017-09-01

    In response to the identification problem concerning multi-degree of freedom (MDOF) nonlinear systems, this study presents the extended forward orthogonal regression (EFOR) based on predicted residual sums of squares (PRESS) to construct a nonlinear dynamic parametrical model. The proposed parametrical model is based on the non-linear autoregressive with exogenous inputs (NARX) model and aims to explicitly reveal the physical design parameters of the system. The PRESS-based EFOR algorithm is proposed to identify such a model for MDOF systems. By using the algorithm, we built a common-structured model based on the fundamental concept of evaluating its generalization capability through cross-validation. The resulting model aims to prevent over-fitting with poor generalization performance caused by the average error reduction ratio (AERR)-based EFOR algorithm. Then, a functional relationship is established between the coefficients of the terms and the design parameters of the unified model. Moreover, a 5-DOF nonlinear system is taken as a case to illustrate the modeling of the proposed algorithm. Finally, a dynamic parametrical model of a cantilever beam is constructed from experimental data. Results indicate that the dynamic parametrical model of nonlinear systems, which depends on the PRESS-based EFOR, can accurately predict the output response, thus providing a theoretical basis for the optimal design of modeling methods for MDOF nonlinear systems.

  12. Can finite element models detect clinically inferior cemented hip implants?

    NARCIS (Netherlands)

    Stolk, J.; Maher, S.A.; Verdonschot, N.J.J.; Prendergast, P.J.; Huiskes, R.

    2003-01-01

    Rigorous preclinical testing of cemented hip prostheses against the damage accumulation failure scenario will reduce the incidence of aseptic loosening. For that purpose, a finite element simulation is proposed that predicts damage accumulation in the cement mantle and prosthetic migration. If the

  13. A model-based approach to stabilizing crutch supported paraplegic standing by artifical hip joint stiffness

    OpenAIRE

    van der Spek, J.H.; Veltink, Petrus H.; Hermens, Hermanus J.; Koopman, Hubertus F.J.M.; Boom, H.B.K.

    2003-01-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hi...

  14. Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function.

    Science.gov (United States)

    Resnick, Barbara; Gruber-Baldini, Ann L; Hicks, Gregory; Ostir, Glen; Klinedinst, N Jennifer; Orwig, Denise; Magaziner, Jay

    2016-07-01

    Measurement of physical function post hip fracture has been conceptualized using multiple different measures. This study tested a comprehensive measurement model of physical function. This was a descriptive secondary data analysis including 168 men and 171 women post hip fracture. Using structural equation modeling, a measurement model of physical function which included grip strength, activities of daily living, instrumental activities of daily living, and performance was tested for fit at 2 and 12 months post hip fracture, and among male and female participants. Validity of the measurement model of physical function was evaluated based on how well the model explained physical activity, exercise, and social activities post hip fracture. The measurement model of physical function fit the data. The amount of variance the model or individual factors of the model explained varied depending on the activity. Decisions about the ideal way in which to measure physical function should be based on outcomes considered and participants. The measurement model of physical function is a reliable and valid method to comprehensively measure physical function across the hip fracture recovery trajectory. © 2015 Association of Rehabilitation Nurses.

  15. HIP (hot isostatic pressing) sintering of Tantalum (Ta) and tantalum carbide (TaC) powder mixture: relations between microstructure and properties

    International Nuclear Information System (INIS)

    Valin, F.; Schnedecker, M.

    1994-01-01

    HIP sintering at 1630 C and 195 MPa, during 2 hours, can be used for complete densification of mixtures of commercial tantalum carbide and tantalum powders. HIPed material properties are depending upon initial compositions. For C/Ta ratios inferior to 80%, the monocarbide structure is preserved. A partial ordering of the carbon vacancies will result, for TaC(0.80), in microhardness maximization. The microstructurally homogenous TaC(0.45) shows an excellent toughness. 2 figs., 2 refs

  16. Development and Validation of Perioperative Risk-Adjustment Models for Hip Fracture Repair, Total Hip Arthroplasty, and Total Knee Arthroplasty.

    Science.gov (United States)

    Schilling, Peter L; Bozic, Kevin J

    2016-01-06

    Comparing outcomes across providers requires risk-adjustment models that account for differences in case mix. The burden of data collection from the clinical record can make risk-adjusted outcomes difficult to measure. The purpose of this study was to develop risk-adjustment models for hip fracture repair (HFR), total hip arthroplasty (THA), and total knee arthroplasty (TKA) that weigh adequacy of risk adjustment against data-collection burden. We used data from the American College of Surgeons National Surgical Quality Improvement Program to create derivation cohorts for HFR (n = 7000), THA (n = 17,336), and TKA (n = 28,661). We developed logistic regression models for each procedure using age, sex, American Society of Anesthesiologists (ASA) physical status classification, comorbidities, laboratory values, and vital signs-based comorbidities as covariates, and validated the models with use of data from 2012. The derivation models' C-statistics for mortality were 80%, 81%, 75%, and 92% and for adverse events were 68%, 68%, 60%, and 70% for HFR, THA, TKA, and combined procedure cohorts. Age, sex, and ASA classification accounted for a large share of the explained variation in mortality (50%, 58%, 70%, and 67%) and adverse events (43%, 45%, 46%, and 68%). For THA and TKA, these three variables were nearly as predictive as models utilizing all covariates. HFR model discrimination improved with the addition of comorbidities and laboratory values; among the important covariates were functional status, low albumin, high creatinine, disseminated cancer, dyspnea, and body mass index. Model performance was similar in validation cohorts. Risk-adjustment models using data from health records demonstrated good discrimination and calibration for HFR, THA, and TKA. It is possible to provide adequate risk adjustment using only the most predictive variables commonly available within the clinical record. This finding helps to inform the trade-off between model performance and data

  17. A new small-animal model for the study of acquired heterotopic ossification after hip surgery.

    Science.gov (United States)

    Anthonissen, Joris; Ossendorf, Christian; Hock, Johanna Lisa; Ritz, Ulrike; Hofmann, Alexander; Rommens, Pol Maria

    2015-01-01

    Heterotopic ossification (HO)--the formation of bone in soft tissues--is a frequent problem after surgery of the hip and pelvis, but little is known about its underlying pathogenic mechanisms. It is vital to study the underlying pathogenesis in animal models to develop and evaluate new prophylactic regimens directed against HO. However, previously developed small-animal models for the study of HO imitate neither surgery nor trauma-mechanisms that potentially cause HO. Hence, the goal of this study was to develop a novel small-animal model imitating hip surgery that can reliably produce HO. Twenty male Wistar rats were subjected to surgery of the right hip during which the femoral canal was reamed in three steps up to 2 mm, and a muscle lesion was made. Twelve weeks after surgery, the amount of heterotopic bone was assessed using micro-computed tomography. Eighteen of 20 animals showed HO around the hip 12 weeks after surgery. The amount of heterotopic bone varied from very small particles up to near ankylosis. A rat model of hip/pelvic surgery that does not use exogenous osteogenic stimulus and can reliably produce HO was developed.

  18. Identification Trouble Valve Destruction On Hidroulic Press Breaker Model MPV.1620 ''DAVY-ITALlA''

    International Nuclear Information System (INIS)

    Paidjo; Pinitojo; Hafid, Abdul; Musa, Tamsil; Sagino

    2000-01-01

    To 'utility instalation examination and operation test, how long capacity to appear on the severaly valve.Torned valve on hidroulic press breaker is three sample: The first directional control valve type. 4 WE 10 H 32 / CE 24 N 9 Z4. Coil: Hydronorma GZ . 63-4 -A. 476. 24VDC, 1,46 A. For two and three is boll spriral spring valve Process operation explanation a short is oil lubrication to pump from reception center tank in to directional control valve then distributed. anything to boll spiral spring valve continued to hidroulic piston for pressed the sample job / plate thickness maximum = 16 mm with to different corner model, maximum press = 160 bar.Hindrance principle is to utilize operation test, hidroulic piston movement botom-up is smothly 0 whereas botom-down went no smoothly. Operation test property to utilize repeated resutls of the aqua. Hindrance / broken the fist estimate that the hole oil works at the directional control valve to threadbore hidroulic piston, wherever preasure not maximum to manometer indicate = 0 bar, at the moment to utilize operation. The second on the boll spiral spring valve no maximum, then to utilize servise detail and to utilize operation test againt. The results from operation test to concende destruction at the boll spiral spring valve, wherever after over houling to appear boll massive place position possessed spring wire> 3 mm to twist of couse preasure to press hidroulic piston no maximum because from leaking

  19. Analysis of Muscle Activity Utilizing Bench Presses in the AnyBody Simulation Modelling System

    Directory of Open Access Journals (Sweden)

    Zhongqiu Ji

    2016-01-01

    Full Text Available Using the AnyBody human modeling system with identical weights and varying grip distance (40.0 cm, 50.0 cm, and 60.0 cm, the stress distribution for the pectoralis and the muscle of upper extremity during a bench press was simulated, and the surface myoelectricity (EMG method was validated. Methods. The physical parameters driving the model of the human body were selected as weights of 35.0% (25.0 kg and grip distances. Conclusion. The validation of AnyBody software was proved as a high validity by using EMG test of four muscles’ activity compared to AnyBody software. During a bench press, the pectoralis major is the main muscle, the pectoralis major discharge increases with the height of barbell increases, and the pectoralis major discharge decreases as the short grip width increases. When the grip width equals the shoulder width, the value of pectoralis minor is lowest; when the grip width is smaller or larger than the shoulder width, the value is larger. As the short grip distance increases, the discharge of posterior deltoid muscle and triceps surface myoelectricity increases; thus, as the short grip distance increases, the deltoid muscle and triceps assist the pectoralis major during a bench press.

  20. Developing a risk prediction model for the functional outcome after hip arthroscopy.

    Science.gov (United States)

    Stephan, Patrick; Röling, Maarten A; Mathijssen, Nina M C; Hannink, Gerjon; Bloem, Rolf M

    2018-04-19

    Hip arthroscopic treatment is not equally beneficial for every patient undergoing this procedure. Therefore, the purpose of this study was to develop a clinical prediction model for functional outcome after surgery based on preoperative factors. Prospective data was collected on a cohort of 205 patients having undergone hip arthroscopy between 2011 and 2015. Demographic and clinical variables and patient reported outcome (PRO) scores were collected, and considered as potential predictors. Successful outcome was defined as either a Hip Outcome Score (HOS)-ADL score of over 80% or improvement of 23%, defined by the minimal clinical important difference, 1 year after surgery. The prediction model was developed using backward logistic regression. Regression coefficients were converted into an easy to use prediction rule. The analysis included 203 patients, of which 74% had a successful outcome. Female gender (OR: 0.37 (95% CI 0.17-0.83); p = 0.02), pincer impingement (OR: 0.47 (95% CI 0.21-1.09); p = 0.08), labral tear (OR: 0.46 (95% CI 0.20-1.06); p = 0.07), HOS-ADL score (IQR OR: 2.01 (95% CI 0.99-4.08); p = 0.05), WHOQOL physical (IQR OR: 0.43 (95% CI 0.22-0.87); p = 0.02) and WHOQOL psychological (IQR OR: 2.40 (95% CI 1.38-4.18); p = prediction model of successful functional outcome 1 year after hip arthroscopy. The model's discriminating accuracy turned out to be fair, as 71% (95% CI: 64-80%) of the patients were classified correctly. The developed prediction model can predict the functional outcome of patients that are considered for a hip arthroscopic intervention, containing six easy accessible preoperative risk factors. The model can be further improved trough external validation and/or adding additional potential predictors.

  1. Validation of a Dry Model for Assessing the Performance of Arthroscopic Hip Labral Repair.

    Science.gov (United States)

    Phillips, Lisa; Cheung, Jeffrey J H; Whelan, Daniel B; Murnaghan, Michael Lucas; Chahal, Jas; Theodoropoulos, John; Ogilvie-Harris, Darrell; Macniven, Ian; Dwyer, Tim

    2017-07-01

    Arthroscopic hip labral repair is a technically challenging and demanding surgical technique with a steep learning curve. Arthroscopic simulation allows trainees to develop these skills in a safe environment. The purpose of this study was to evaluate the use of a combination of assessment ratings for the performance of arthroscopic hip labral repair on a dry model. Cross-sectional study; Level of evidence, 3. A total of 47 participants including orthopaedic surgery residents (n = 37), sports medicine fellows (n = 5), and staff surgeons (n = 5) performed arthroscopic hip labral repair on a dry model. Prior arthroscopic experience was noted. Participants were evaluated by 2 orthopaedic surgeons using a task-specific checklist, the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task completion time, and a final global rating scale. All procedures were video-recorded and scored by an orthopaedic fellow blinded to the level of training of each participant. The internal consistency/reliability (Cronbach alpha) using the total ASSET score for the procedure was high (intraclass correlation coefficient > 0.9). One-way analysis of variance for the total ASSET score demonstrated a difference between participants based on the level of training ( F 3,43 = 27.8, P 0.9). The results of this study demonstrate that the use of dry models to assess the performance of arthroscopic hip labral repair by trainees is both valid and reliable. Further research will be required to demonstrate a correlation with performance on cadaveric specimens or in the operating room.

  2. Coordination pays off: a comparison of two models for organizing hip fracture care, outcomes and costs.

    Science.gov (United States)

    Löfgren, Susanne; Rehnberg, Clas; Ljunggren, Gunnar; Brommels, Mats

    2015-01-01

    With the "graying" of the population, hip fractures place an increasing burden on health systems and call for efficient forms of care. The aim was to compare two models of organizing hip fracture care at one university hospital working at two sites. The differences in organization were coordinated care provided in one of the sites and traditional care, divided between different institutions, in the other. The study was conducted at a Swedish university hospital and included all 503 hip fracture patients, admitted during the 1-year period of February 2009 through January 2010. Patient gender, age, type of fracture, admission and discharge dates were documented. The patients were surveyed of their health-related quality of life at the time of admission and at 4 and 12 months after discharge. The costs for the inpatient care episode were estimated using three costing methods. The coordinated care model resulted in a shorter hospital stay and consistently lower costs. There was no difference between patient-reported quality of life. The care of hip fracture patients coordinated by a geriatric ward throughout the whole care episode is more cost-efficient than uncoordinated where patients are transferred to other institutions for rehabilitation. © 2014 The Authors. The International Journal of Health Planning and Management published by John Wiley & Sons Ltd.

  3. Comprehensive care of elderly patients with hip fracture: the orthogeriatric model

    OpenAIRE

    Carlo Frondini; Maria L. Lunardelli

    2013-01-01

    Introduction: Hip fractures in the elderly are a major source of morbidity and mortality. Interdisciplinary hospital care models proposed for the treatment of these patients include consultant teams, integrated orthopedic-geriatric care, and comprehensive geriatric-led care settings. A prospective interventional cohort study was conducted in 4 public hospitals in the Emilia-Romagna Region of Italy to compare the outcomes of these different care models. This report presents the preliminary res...

  4. Hip, Hip, Soret!

    Science.gov (United States)

    Müller-Plathe, Florian

    Many years ago, Ludwig did detect the behaviour now called the Soret effect. Sodium sulphate in eighteen-fifty-six did not obediently follow Fick's first law. But if he cooled down one side the salt went left, the water to the right. He was surprised in every way. Hip, hip, Soret!

  5. Cost-effectiveness of total hip and knee replacements for the Australian population with osteoarthritis: discrete-event simulation model.

    Directory of Open Access Journals (Sweden)

    Hideki Higashi

    Full Text Available BACKGROUND: Osteoarthritis constitutes a major musculoskeletal burden for the aged Australians. Hip and knee replacement surgeries are effective interventions once all conservative therapies to manage the symptoms have been exhausted. This study aims to evaluate the cost-effectiveness of hip and knee replacements in Australia. To our best knowledge, the study is the first attempt to account for the dual nature of hip and knee osteoarthritis in modelling the severities of right and left joints separately. METHODOLOGY/PRINCIPAL FINDINGS: We developed a discrete-event simulation model that follows up the individuals with osteoarthritis over their lifetimes. The model defines separate attributes for right and left joints and accounts for several repeat replacements. The Australian population with osteoarthritis who were 40 years of age or older in 2003 were followed up until extinct. Intervention effects were modelled by means of disability-adjusted life-years (DALYs averted. Both hip and knee replacements are highly cost effective (AUD 5,000 per DALY and AUD 12,000 per DALY respectively under an AUD 50,000/DALY threshold level. The exclusion of cost offsets, and inclusion of future unrelated health care costs in extended years of life, did not change the findings that the interventions are cost-effective (AUD 17,000 per DALY and AUD 26,000 per DALY respectively. However, there was a substantial difference between hip and knee replacements where surgeries administered for hips were more cost-effective than for knees. CONCLUSIONS/SIGNIFICANCE: Both hip and knee replacements are cost-effective interventions to improve the quality of life of people with osteoarthritis. It was also shown that the dual nature of hip and knee OA should be taken into account to provide more accurate estimation on the cost-effectiveness of hip and knee replacements.

  6. Comprehensive care of elderly patients with hip fracture: the orthogeriatric model

    Directory of Open Access Journals (Sweden)

    Carlo Frondini

    2013-04-01

    Full Text Available Introduction: Hip fractures in the elderly are a major source of morbidity and mortality. Interdisciplinary hospital care models proposed for the treatment of these patients include consultant teams, integrated orthopedic-geriatric care, and comprehensive geriatric-led care settings. A prospective interventional cohort study was conducted in 4 public hospitals in the Emilia-Romagna Region of Italy to compare the outcomes of these different care models. This report presents the preliminary results obtained with an orthogeriatric model in one of these centers, a large teaching hospital in Bologna. Materials and methods: Beginning in February 2008, all patients older than 75 years admitted to the University of Bologna’s Sant’Orsola-Malpighi Hospital for hip fractures were cared for in an orthogeriatric unit. The unit consisted of 10 beds in the orthopedic ward that were managed by a geriatric specialist and a multidisciplinary team, which met daily and included an orthopedic surgeon, a physiatrist, a nurse case-manager, staff nurses, a physical therapist, and a social worker. The management protocol included a thorough geriatric work-up to identify comorbidities and risk factors, systematic assessment and prevention of pain and acute disorientation, early verticalization and moblization, postacute rehabilitation therapy, family support, and regular follow-up after discharge. Preliminary results were compared with those achieved in the same orthopedic ward prior to the creation of the Orthogeriatric Unit. Results: During 2008, 226 elderly patients (mean age 86.2 + 5.5 years, 73.4% of whom were women, were admitted to the Orthogeriatric Unit for hip fractures. The mean Charlson comorbidity index of this cohort was 3.0 + 1.8. Half the patients had Activity of Daily Living scores < 4, and cognitive impairment was common (mean score on Short Portable Mental Status Questionnaire: 5.9 + 3.2. Compared with figures obtained in the hospital

  7. A patient-specific model of the biomechanics of hip reduction for neonatal Developmental Dysplasia of the Hip: Investigation of strategies for low to severe grades of Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Huayamave, Victor; Rose, Christopher; Serra, Sheila; Jones, Brendan; Divo, Eduardo; Moslehy, Faissal; Kassab, Alain J; Price, Charles T

    2015-07-16

    A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  9. Simplex network modeling for press-molded ceramic bodies incorporated with granite waste

    International Nuclear Information System (INIS)

    Pedroti, L.G.; Vieira, C.M.F.; Alexandre, J.; Monteiro, S.N.; Xavier, G.C.

    2012-01-01

    Extrusion of a clay body is the most commonly applied process in the ceramic industries for manufacturing structural block. Nowadays, the assembly of such blocks through a fitting system that facilitates the final mounting is gaining attention owing to the saving in material and reducing in the cost of the building construction. In this work, the ideal composition of clay bodies incorporated with granite powder waste was investigated for the production of press-molded ceramic blocks. An experimental design was applied to determine the optimum properties and microstructures involving not only the precursors compositions but also the press and temperature conditions. Press load from 15 ton and temperatures from 850 to 1050°C were considered. The results indicated that varying mechanical strength of 2 MPa to 20 MPa and varying water absorption of 19% to 30%. (author)

  10. Early coordinated rehabilitation in acute phase after hip fracture - a model for increased patient participation.

    Science.gov (United States)

    Asplin, Gillian; Carlsson, Gunnel; Zidén, Lena; Kjellby-Wendt, Gunilla

    2017-10-17

    Studies have shown that patients with hip fracture treated in a Comprehensive Geriatric Care (CGC) unit report better results in comparison to orthopaedic care. Furthermore, involving patients in their healthcare by encouraging patient participation can result in better quality of care and improved outcomes. To our knowledge no study has been performed comparing rehabilitation programmes within a CGC unit during the acute phase after hip fracture with focus on improving patients' perceived participation and subsequent effect on patients' function. A prospective, controlled, intervention performed in a CGC unit and compared with standard care. A total of 126 patients with hip fracture were recruited who were prior to fracture; community dwelling, mobile indoors and independent in personal care. Intervention Group (IG): 63 patients, mean age 82.0 years and Control Group (CG): 63 patients mean age 80.5 years. coordinated rehabilitation programme with early onset of patient participation and intensified occupational therapy and physiotherapy after hip fracture surgery. The primary outcome measure was self-reported patient participation at discharge. Secondary outcome measures were: TLS-BasicADL; Bergs Balance Scale (BBS); Falls Efficacy Scale FES(S); Short Physical Performance Battery (SPPB) and Timed Up and Go (TUG) at discharge and 1 month and ADL staircase for instrumental ADL at 1 month. At discharge a statistically significant greater number of patients in the IG reported higher levels of participation (p < 0.05) and independence in lower body hygiene (p < 0.05) and dressing (p < 0.001). There were however no statistically significant differences at discharge and 1 month between groups in functional balance and confidence, performance measures or risk for falls. This model of OT and PT coordinated inpatient rehabilitation had a positive effect on patients' perceived participation in their rehabilitation and ADL at discharge but did not appear to

  11. Experimental and modelling studies on the solvent assisted hydraulic pressing of dehulled rubber seeds

    NARCIS (Netherlands)

    Abduh, Muhammad Yusuf; Rasrendra, C. B.; Subroto, Erna; Manurung, Robert; Heeres, Hero J.

    2016-01-01

    A systematic study on the expression of rubber seed oil from dehulled rubber seeds in a hydraulic press was performed in the presence and absence of ethanol. The effect of seed moisture content (0–6 wt%, w.b.), temperature (35–105 °C), pressure (15–25 MPa) and ethanol to seed ratio (0–21%v/w) on the

  12. —Pricing Digital Content Product Lines: A Model and Application for the National Academies Press

    OpenAIRE

    P. K. Kannan; Barbara Kline Pope; Sanjay Jain

    2009-01-01

    We examine the problem of how a content provider, specifically the National Academies Press (NAP), can optimally price the different forms of its product—print and PDF—that it sells online. Whereas products in the traditional product line generally tend to be substitutes, the different content product forms could range from being substitutes to being complements across customers. Thus the content provider can possibly sell bundles of the product forms, leading to additional revenue. We first ...

  13. Hip pain

    Science.gov (United States)

    ... from a chair, walking, climbing stairs, and driving Hamstring strain Iliotibial band syndrome Hip flexor strain Hip ... and cool down afterward. Stretch your quadriceps and hamstrings. Avoid running straight down hills. Walk down instead. ...

  14. A two-dimensional model of the pressing section of a paper machine including dynamic capillary effects

    KAUST Repository

    Iliev, Oleg P.

    2013-05-15

    Paper production is a problem with significant importance for society; it is also a challenging topic for scientific investigation. This study is concerned with the simulation of the pressing section of a paper machine. A two-dimensional model is developed to account for the water flow within the pressing zone. A Richards-type equation is used to describe the flow in the unsaturated zone. The dynamic capillary pressure-saturation relation is adopted for the paper production process. The mathematical model accounts for the coexistence of saturated and unsaturated zones in a multilayer computational domain. The discretization is performed by the MPFA-O method. Numerical experiments are carried out for parameters that are typical of the production process. The static and dynamic capillary pressure-saturation relations are tested to evaluate the influence of the dynamic capillary effect. © 2013 Springer Science+Business Media Dordrecht.

  15. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  16. Effects of hip joint position and intra-capsular volume on hip joint intra-capsular pressure: a human cadaveric model

    Directory of Open Access Journals (Sweden)

    Tse Paul

    2009-04-01

    Full Text Available Abstract Background Increase in hip intra-capsular pressure has been implicated in various hip pathologies, such as avascular necrosis complicating undisplaced femoral neck fracture. Our study aimed at documenting the relationship between intra-capsular volume and pressure in various hip positions. Methods Fifty-two cadaveric hips were studied. An electronic pressure-monitoring catheter recorded the intra-capsular hip pressure after each instillation of 2 ml of normal saline and in six hip positions. Results In neutral hip position, the control position for investigation, intra-capsular pressure remained unchanged when its content was below 10 ml. Thereafter, it increased exponentially. When the intra-capsular volume was 12 ml, full abduction produced a 2.1-fold increase (p = 0.028 of the intra-capsular hip joint pressure; full external rotation and full internal rotation increased the pressure by at least 4-fold (p Conclusion Intra-capsular pressure increases with its volume, but with a wide variation with different positions. It would be appropriate to recommend that hips with haemarthrosis or effusion should be positioned in 45-degree flexion.

  17. Rapid Prototyping 3D Model in Treatment of Pediatric Hip Dysplasia: A Case Report.

    Science.gov (United States)

    Holt, Andrew M; Starosolski, Zbigniew; Kan, J Herman; Rosenfeld, Scott B

    2017-01-01

    Rapid prototyping is an emerging technology that integrates common medical imaging with specialized production mechanisms to create detailed anatomic replicas. 3D-printed models of musculoskeletal anatomy have already proven useful in orthopedics and their applications continue to expand. We present the case of a 10 year-old female with Down syndrome and left acetabular dysplasia and chronic hip instability who underwent periacetabular osteotomy. A rapid prototyping 3D model was created to better understand the anatomy, counsel the family about the problem and the surgical procedure, as well as guide surgical technique. The intricate detail and size match of the model with the patient's anatomy offered unparalleled, hands-on experience with the patient's anatomy pre-operatively and improved surgical precision. Our experience with rapid prototyping confirmed its ability to enhance orthopedic care by improving the surgeon's ability to understand complex anatomy. Additionally, we report a new application utilizing intraoperative fluoroscopic comparison of the model and patient to ensure surgical precision and minimize the risk of complications. This technique could be used in other challenging cases. The increasing availability of rapid prototyping welcomes further use in all areas of orthopedics.

  18. Auxiliary equipment and special techniques used for hot isostatic pressing

    International Nuclear Information System (INIS)

    Pfeffer, J.B.; Odebo, U.

    1977-01-01

    The largest use for hot isostatic pressing (HIP) in production is in the consolidation of powder. In principle, powder is filled into a capsule of metal or glass, and the capsule is evacuated, sealed and loaded into the hot isostatic press. Consolidation takes place in the hot isostatic press, at which time the consolidated capsule is removed from the press and the encapsulation material is removed from the consolidated powder body. In both densification and defect healing, HIP is carried out without encapsulating the material. This is possible as the materials that lend themselves to HIP healing initially have a high density without communicating pores; therefore, the material acts as its own capsule. Considerations outside of the hot isostatic press that must be taken into account are examined. Information is included on powder manufacture, fabrication of capsules, powder handling, capsule sealing, and loading and unloading the press

  19. Press Start

    Science.gov (United States)

    Harteveld, Casper

    This level sets the stage for the design philosophy called “Triadic Game Design” (TGD). This design philosophy can be summarized with the following sentence: it takes two to tango, but it takes three to design a meaningful game or a game with a purpose. Before the philosophy is further explained, this level will first delve into what is meant by a meaningful game or a game with a purpose. Many terms and definitions have seen the light and in this book I will specifically orient at digital games that aim to have an effect beyond the context of the game itself. Subsequently, a historical overview is given of the usage of games with a serious purpose which starts from the moment we human beings started to walk on our feet till our contemporary society. It turns out that we have been using games for all kinds of non-entertainment purposes for already quite a long time. With this introductory material in the back of our minds, I will explain the concept of TGD by means of a puzzle. After that, the protagonist of this book, the game Levee Patroller, is introduced. Based on the development of this game, the idea of TGD, which stresses to balance three different worlds, the worlds of Reality, Meaning, and Play, came into being. Interested? Then I suggest to quickly “press start!”

  20. Mathematical model of consolidation of fine concrete mixtures with different mobility, casted by vacuumizing and axial pressing in layers

    Directory of Open Access Journals (Sweden)

    Dedeneva Elena

    2017-01-01

    Full Text Available A mathematical model allowing establishing regularities in the consolidation processes of fine-grained concrete mixtures with different mobility and compaction methods has been worked out. This study is based on two-phase systems and nonlinear character of their consolidation. It resolves the question of the choice of vacuumizing optimal parameters and axial pressing in layers for molding of thin-walled products such as concrete roof tiles and concrete pipe products. Finally, we can get products without heat treatment by the materials and energy-saving technologies.

  1. Male sexual strategies modify ratings of female models with specific waist-to-hip ratios.

    Science.gov (United States)

    Brase, Gary L; Walker, Gary

    2004-06-01

    Female waist-to-hip ratio (WHR) has generally been an important general predictor of ratings of physical attractiveness and related characteristics. Individual differences in ratings do exist, however, and may be related to differences in the reproductive tactics of the male raters such as pursuit of short-term or long-term relationships and adjustments based on perceptions of one's own quality as a mate. Forty males, categorized according to sociosexual orientation and physical qualities (WHR, Body Mass Index, and self-rated desirability), rated female models on both attractiveness and likelihood they would approach them. Sociosexually restricted males were less likely to approach females rated as most attractive (with 0.68-0.72 WHR), as compared with unrestricted males. Males with lower scores in terms of physical qualities gave ratings indicating more favorable evaluations of female models with lower WHR. The results indicate that attractiveness and willingness to approach are overlapping but distinguishable constructs, both of which are influenced by variations in characteristics of the raters.

  2. One step HIP canning of powder metallurgy composites

    Science.gov (United States)

    Juhas, John J. (Inventor)

    1990-01-01

    A single step is relied on in the canning process for hot isostatic pressing (HIP) powder metallurgy composites. The binders are totally removed while the HIP can of compatible refractory metal is sealed at high vacuum and temperature. This eliminates outgassing during hot isostatic pressing.

  3. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important parameter...... for the chip, because it influences contact electrical resistance, contact thermal resistance and power cycling capability. Ideally, the clamping force should be equally distributed among chips, in order to maximize the reliability of the PP IGBT. The model is built around a hypothetical PP IGBT with 9 chips......, and it has numerous simplifications in order to reduce the simulation time as much as possible. The developed model is used to analyze the clamping force distribution among chips, in various study cases, where uniform and non-uniform clamping pressures are applied on the studied PP IGBT....

  4. Dynamic thermal modelling and analysis of press-pack IGBTs both at component-level and chip-level

    DEFF Research Database (Denmark)

    Busca, Cristian; Teodorescu, Remus; Blaabjerg, Frede

    2013-01-01

    curves under various mechanical clamping conditions are derived. Moreover, the deformation of the internal components of the PP IGBT under operating-like conditions is investigated with the help of the thermal models and the coefficient of thermal expansion (CTE) information.......Thermal models are needed when designing power converters for Wind Turbines (WTs) in order to carry out thermal and reliability assessment of certain designs. Usually the thermal models of Insulated Gate Bipolar Transistors (IGBTs) are given in the datasheet in various forms at component......-level, not taking into account the thermal distribution among the chips. This is especially relevant in the case of Press-Pack (PP) IGBTs because any non-uniformity of the clamping pressure can affect the chip-level thermal impedances. This happens because the contact thermal resistances in the thermal impedance...

  5. MICROSTRUCTURAL ANALYSIS OF HOT ISOSTATICALLY PRESSED AL-SIC

    NARCIS (Netherlands)

    Bronsveld, P.M.; Hosson, J.Th. De; Sargent, M.A.; Alsem, W.H.M.

    1991-01-01

    The difference between extruded and hot isostatically pressed (HIP) Al6061 both with a T6 final heat treatment and with a 30 wt.% SiC particulate reinforcement is one of densification. The higher density of the HIP material is not translated into a stronger material. The Mg2Si precipitation is

  6. An Assessment of the Ductile Fracture Behavior of Hot Isostatically Pressed and Forged 304L Stainless Steel

    Science.gov (United States)

    Cooper, A. J.; Smith, R. J.; Sherry, A. H.

    2017-05-01

    Type 300 austenitic stainless steel manufactured by hot isostatic pressing (HIP) has recently been shown to exhibit subtly different fracture behavior from that of equivalent graded forged steel, whereby the oxygen remaining in the component after HIP manifests itself in the austenite matrix as nonmetallic oxide inclusions. These inclusions facilitate fracture by acting as nucleation sites for the initiation, growth, and coalescence of microvoids in the plastically deforming austenite matrix. Here, we perform analyses based on the Rice-Tracey (RT) void growth model, supported by instrumented Charpy and J-integral fracture toughness testing at ambient temperature, to characterize the degree of void growth ahead of both a V-notch and crack in 304L stainless steel. We show that the hot isostatically pressed (HIP'd) 304L steel exhibits a lower critical void growth at the onset of fracture than that observed in forged 304L steel, which ultimately results in HIP'd steel exhibiting lower fracture toughness at initiation and impact toughness. Although the reduction in toughness of HIP'd steel is not detrimental to its use, due to the steel's sufficiently high toughness, the study does indicate that HIP'd and forged 304L steel behave as subtly different materials at a microstructural level with respect to their fracture behavior.

  7. Designing a Care Pathway Model - A Case Study of the Outpatient Total Hip Arthroplasty Care Pathway.

    Science.gov (United States)

    Oosterholt, Robin I; Simonse, Lianne Wl; Boess, Stella U; Vehmeijer, Stephan Bw

    2017-03-09

    Although the clinical attributes of total hip arthroplasty (THA) care pathways have been thoroughly researched, a detailed understanding of the equally important organisational attributes is still lacking. The aim of this article is to contribute with a model of the outpatient THA care pathway that depicts how the care team should be organised to enable patient discharge on the day of surgery. The outpatient THA care pathway enables patients to be discharged on the day of surgery, shortening the length of stay and intensifying the provision and organisation of care. We utilise visual care modelling to construct a visual design of the organisation of the care pathway. An embedded case study was conducted of the outpatient THA care pathway at a teaching hospital in the Netherlands. The data were collected using a visual care modelling toolkit in 16 semi-structured interviews. Problems and inefficiencies in the care pathway were identified and addressed in the iterative design process. The results are two visual models of the most critical phases of the outpatient THA care pathway: diagnosis & preparation (1) and mobilisation & discharge (4). The results show the care team composition, critical value exchanges, and sequence that enable patient discharge on the day of surgery. The design addressed existing problems and is an optimisation of the case hospital's pathway. The network of actors consists of the patient (1), radiologist (1), anaesthetist (1), nurse specialist (1), pharmacist (1), orthopaedic surgeon (1,4), physiotherapist (1,4), nurse (4), doctor (4) and patient application (1,4). The critical value exchanges include patient preparation (mental and practical), patient education, aligned care team, efficient sequence of value exchanges, early patient mobilisation, flexible availability of the physiotherapist, functional discharge criteria, joint decision making and availability of the care team.

  8. Inpatient cost for hip fracture patients managed with an orthogeriatric care model in Singapore.

    Science.gov (United States)

    Tan, Lester Teong Jin; Wong, Seng Joung; Kwek, Ernest Beng Kee

    2017-03-01

    The estimated incidence of hip fractures worldwide was 1.26 million in 1990 and is expected to double to 2.6 million by 2025. The cost of care for hip fracture patients is a significant economic burden. This study aimed to look at the inpatient cost of hip fractures among elderly patients placed under a mature orthogeriatric co-managed system. This study was a retrospective analysis of 244 patients who were admitted to the Department of Orthopaedics of Tan Tock Seng Hospital, Singapore, in 2011 for hip fractures under a mature orthogeriatric hip fracture care path. Information regarding costs, surgical procedures performed and patient demographics was collected. The mean cost of hospitalisation was SGD 13,313.81. The mean cost was significantly higher for the patients who were managed surgically than for the patients who were managed non-surgically (SGD 14,815.70 vs. SGD 9,011.38; p 48 hours was SGD 2,716.63. Reducing the time to surgery and preventing pre- and postoperative complications can help reduce overall costs. A standardised care path that empowers allied health professionals can help to reduce perioperative complications, and a combined orthogeriatric care service can facilitate prompt surgical treatment. Copyright: © Singapore Medical Association

  9. Alternative Payment Models Should Risk-Adjust for Conversion Total Hip Arthroplasty: A Propensity Score-Matched Study.

    Science.gov (United States)

    McLawhorn, Alexander S; Schairer, William W; Schwarzkopf, Ran; Halsey, David A; Iorio, Richard; Padgett, Douglas E

    2017-12-06

    For Medicare beneficiaries, hospital reimbursement for nonrevision hip arthroplasty is anchored to either diagnosis-related group code 469 or 470. Under alternative payment models, reimbursement for care episodes is not further risk-adjusted. This study's purpose was to compare outcomes of primary total hip arthroplasty (THA) vs conversion THA to explore the rationale for risk adjustment for conversion procedures. All primary and conversion THAs from 2007 to 2014, excluding acute hip fractures and cancer patients, were identified in the National Surgical Quality Improvement Program database. Conversion and primary THA patients were matched 1:1 using propensity scores, based on preoperative covariates. Multivariable logistic regressions evaluated associations between conversion THA and 30-day outcomes. A total of 2018 conversions were matched to 2018 primaries. There were no differences in preoperative covariates. Conversions had longer operative times (148 vs 95 minutes, P reimbursement models shift toward bundled payment paradigms, conversion THA appears to be a procedure for which risk adjustment is appropriate. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Developmental dysplasia of the hip: A computational biomechanical model of the path of least energy for closed reduction.

    Science.gov (United States)

    Zwawi, Mohammed A; Moslehy, Faissal A; Rose, Christopher; Huayamave, Victor; Kassab, Alain J; Divo, Eduardo; Jones, Brendan J; Price, Charles T

    2017-08-01

    This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.

  11. Hot isostatic-pressing diagrams for fine-particle beryllium powders

    International Nuclear Information System (INIS)

    Stoev, P.I.; Papirov, I.I.; Tikhinskij, G.F.; Vasil'ev, A.A.

    1995-01-01

    Charts of hot isostatic pressing (HIP) for 4 and 8 μm grain beryllium powders are plotted. Values of thickening rates are calculated and their dependences on HIP pressure and temperature are plotted. It is shown, that the relative density powder at growth of HIP pressure and temperature

  12. Hip ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@libero.it [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Garello, Isabella; Marchetti, Alessandra; Palmieri, Federigo; Altafini, Luisa [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Valle, Maura [Radiologia, Gaslini Children Hospital, Genova (Italy); Tagliafico, Alberto [Radiologia, National Institute for Cancer Research, Genoa (Italy)

    2012-12-15

    In newborns, US has an established role in the detection and management of developmental dysplasia of the hip. Later in childhood, when the limping child is a major diagnostic dilemma, US is extremely helpful in the identification of the varied disease processes underlying this condition, as transient synovitis, septic arthritis, Perthes disease and slipped femoral capital epiphysis. In adolescent practicing sporting activities, US is an excellent means to identify apophyseal injures about the pelvic ring, especially when avulsions are undisplaced and difficult-to-see radiographically. Later on, in the adulthood, US is an effective modality to diagnose tendon and muscle injuries about the hip and pelvis, identify effusion or synovitis within the hip joint or its adjacent bursae and guide the treatment of these findings. The aim of this article is to provide a comprehensive review of the most common pathologic conditions about the hip, in which the contribution of US is relevant for the diagnostic work-up.

  13. Hip arthroscopy

    Directory of Open Access Journals (Sweden)

    Henrique Antônio Berwanger de Amorim Cabrita

    2015-06-01

    Full Text Available Hip arthroscopy is a safe method for treating a variety of pathological conditions that were unknown until a decade ago. Femoroacetabular impingement is the commonest of these pathological conditions and the one with the best results when treated early on. The instruments and surgical technique for hip arthroscopy continue to evolve. New indications for hip arthroscopy has been studied as the ligamentum teres injuries, capsular repair in instabilities, dissection of the sciatic nerve and repair of gluteal muscles tears (injuries to the hip rotator cuff, although still with debatable reproducibility. The complication rate is low, and ever-better results with fewer complications should be expected with the progression of the learning curve.

  14. Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model

    Directory of Open Access Journals (Sweden)

    Jacek Białecki

    2014-01-01

    Full Text Available Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS, triple pelvic osteotomy (TPO, total hip replacement (THR, and femoral head and neck resection (FHNE. The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.

  15. Effects of psychotropic agents on extinction of lever-press avoidance in a rat model of anxiety vulnerability

    Directory of Open Access Journals (Sweden)

    Xilu eJiao

    2014-09-01

    Full Text Available Avoidance and its perseveration represent key features of anxiety disorders. Both pharmacological and behavioral approaches (i.e. anxiolytics and extinction therapy have been utilized to modulate avoidance behavior in patients. However, the outcome has not always been desirable. Part of the reason is attributed to the diverse neuropathology of anxiety disorders. Here, we investigated the effect of psychotropic drugs that target various monoamine systems on extinction of avoidance behavior using lever-press avoidance task. Here we used the Wistar-Kyoto (WKY rat, a unique rat model that exhibits facilitated avoidance and extinction resistance along with malfunction of the dopamine (DA system. Sprague Dawley (SD and WKY rats were trained to acquire lever-press avoidance. WKY rats acquired avoidance faster and to a higher level compared to SD rats. During pharmacological treatment, bupropion, and desipramine significantly reduced avoidance response selectively in WKY rats. However, after the discontinuation of drug treatment, only those WKY rats that were previously treated with desipramine exhibited lower avoidance response compared to the control group. In contrast, none of the psychotropic drugs facilitated avoidance extinction in SD rats. Instead, desipramine impaired avoidance extinction and increased non-reinforced response in SD rats. Interestingly, paroxetine, a widely used antidepressant and anxiolytic, exhibited the weakest effect in WKY rats and no effects at all in SD rats. Thus, our data suggest that malfunctions in brain catecholamine system could be one of the underlying etiologies of anxiety-like behavior, particularly avoidance perseveration. Pharmacological manipulation targeting DA and norepinephrine is more effective to facilitate extinction learning in this strain. The data from the present study may shed light on new pharmacological approaches to treat patients with anxiety disorders who are not responding to serotonin re

  16. Changes in hip abductor moment 3 or more years after femoral derotation osteotomy among individuals with cerebral palsy.

    Science.gov (United States)

    Boyer, Elizabeth R; Novacheck, Tom F; Schwartz, Michael H

    2017-09-01

    To examine the effect of femoral derotation osteotomy (FDO) on dimensionless hip abductor moment during gait in children with cerebral palsy. We retrospectively analyzed data from independent ambulators within our database. Postoperative visits 1 year (short-term) and at least 3 years (mid-term) were analyzed. We estimated the coronal plane hip abductor moment arm based on musculoskeletal modeling that accounted for anteversion and hip rotation. There were 140 individuals with a short-term analysis (77 males, 63 females; age at surgery 9y 11mo [range 4y 5mo-17y 5mo]) and 29 with mid-term analysis (15 males, 14 females; age at surgery 8y 7mo [range 4y 5mo-13y 1mo]). At short-term, anteversion and internal hip rotation decreased 35° and 13° respectively, which increased median (IQR) moment arms from 20 (23) per cent below normal to 2 (12) per cent above normal. Dimensionless mean hip abductor moment remained unchanged at short-term. Mid-term anteversion did not change but hip rotation increased 8° and hip abductor moment increased to 0.040 (0.029). There was no change in pelvic and trunk obliquity, although hip abductor strength increased and walking velocity decreased at mid-term. The unexpected lack of improvement in hip abductor moment from pre- to short-term may be caused by gait compensations that unload the hip. The increase in hip abductor moment beyond 3 years postoperatively underscores the benefits of an FDO into adolescence for independent ambulating individuals with cerebral palsy. © 2017 Mac Keith Press.

  17. Preliminary results for HIP bonding Ta to W targets for the materials test station

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, David E [Los Alamos National Laboratory; Maloy, Stuart A [Los Alamos National Laboratory

    2009-01-01

    Tungsten targets for the Materials Test Station (MTS) were clad with thin tantalum cover plates and a tantalum frame using hot isostatic pressing (HIP). A preliminary HIP parameter study showed good bonding and intimate mechanical contact for Ta cover plate thicknesses of 0.25 mm (0.010 inch) and 0.38 mm (0.015 inch). HIP temperatures of full HIP runs were 1500 C (2732 F). HIP pressure was 203 MPa (30 ksi).

  18. Converter Structure-Based Power Loss and Static Thermal Modeling of The Press-Pack IGBT Three-Level ANPC VSC Applied to Multi-MW Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2011-01-01

    performance, the converter structure-based power loss and thermal models are developed in this study for the medium-voltage (MV) three-level active neutral-point-clamped voltage source converter (3L-ANPC-VSC) utilizing 4500 V-1800 A press-pack insulated-gate bipolar transistor-diode pairs and interfacing a 6...

  19. Hip dysplasia and congenital hip dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Nebel, G.; von Torklus, D.

    1981-11-01

    In human genetics and orthopedics quite different answers have been given to the question of hereditary transmission and frequency of hip dysplasia in families of children with congenital hip dislocation. We therefore have made roentgenometric measurements of 110 parents of children with congenital hip dislocation. In 25% we found abnormal flat acetabulae, whereas 12% had pathologic deep hips. This may propose a new concept of morphology of congenital hip dysplasia.

  20. A two-dimensional model of the pressing section of a paper machine including dynamic capillary effects

    KAUST Repository

    Iliev, Oleg P.; Printsypar, Galina; Rief, Stefan

    2013-01-01

    is developed to account for the water flow within the pressing zone. A Richards-type equation is used to describe the flow in the unsaturated zone. The dynamic capillary pressure-saturation relation is adopted for the paper production process. The mathematical

  1. Experimental and Simulation Analysis of Hot Isostatic Pressing of Gas Atomized Stainless Steel 316L Powder Compacts

    International Nuclear Information System (INIS)

    Lin, Dongguo; Park, Seong Jin; Ha, Sangyul; Shin, Youngho; Park, Dong Yong; Chung, Sung Taek; Bollina, Ravi; See, Seongkyu

    2016-01-01

    In this work, both experimental and numerical studies were conducted to investigate the densification behavior of stainless steel 316L (STS 316L) powders during hot isostatic pressing (HIP), and to characterize the mechanical properties of HIPed specimens. The HIP experiments were conducted with gas atomized STS 316L powders with spherical particle shapes under controlled pressure and temperature conditions. The mechanical properties of HIPed samples were determined based on a series of tensile tests, and the results were compared to a reference STS 316L sample prepared by the conventional process, i.e., extrusion and annealing process. Corresponding microstructures before and after tensile tests were observed using scanning electron microscopy and their relationships to the mechanical properties were addressed. Furthermore, a finite element simulation based on the power-law creep model was carried out to predict the density distribution and overall shape change of the STS316L powder compact during HIP process, which agreed well with the experimental results.

  2. Experimental and Simulation Analysis of Hot Isostatic Pressing of Gas Atomized Stainless Steel 316L Powder Compacts

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Dongguo; Park, Seong Jin [Pohang University of Science and Technology, Pohang (Korea, Republic of); Ha, Sangyul [Samsung Electro-Mechanics, Suwon (Korea, Republic of); Shin, Youngho [Doosan Heavy Industries and Construction Co., Ltd., Changwon (Korea, Republic of); Park, Dong Yong [Korea Institute of Energy Research, Daejeon (Korea, Republic of); Chung, Sung Taek [CetaTech Inc., Sacheon (Korea, Republic of); Bollina, Ravi [Bahadurpally Jeedimetla, Hyderabad (India); See, Seongkyu [POSCO, Pohang (Korea, Republic of)

    2016-10-15

    In this work, both experimental and numerical studies were conducted to investigate the densification behavior of stainless steel 316L (STS 316L) powders during hot isostatic pressing (HIP), and to characterize the mechanical properties of HIPed specimens. The HIP experiments were conducted with gas atomized STS 316L powders with spherical particle shapes under controlled pressure and temperature conditions. The mechanical properties of HIPed samples were determined based on a series of tensile tests, and the results were compared to a reference STS 316L sample prepared by the conventional process, i.e., extrusion and annealing process. Corresponding microstructures before and after tensile tests were observed using scanning electron microscopy and their relationships to the mechanical properties were addressed. Furthermore, a finite element simulation based on the power-law creep model was carried out to predict the density distribution and overall shape change of the STS316L powder compact during HIP process, which agreed well with the experimental results.

  3. News/Press Releases

    Data.gov (United States)

    Office of Personnel Management — A press release, news release, media release, press statement is written communication directed at members of the news media for the purpose of announcing programs...

  4. Prediction of Pressing Quality for Press-Fit Assembly Based on Press-Fit Curve and Maximum Press-Mounting Force

    Directory of Open Access Journals (Sweden)

    Bo You

    2015-01-01

    Full Text Available In order to predict pressing quality of precision press-fit assembly, press-fit curves and maximum press-mounting force of press-fit assemblies were investigated by finite element analysis (FEA. The analysis was based on a 3D Solidworks model using the real dimensions of the microparts and the subsequent FEA model that was built using ANSYS Workbench. The press-fit process could thus be simulated on the basis of static structure analysis. To verify the FEA results, experiments were carried out using a press-mounting apparatus. The results show that the press-fit curves obtained by FEA agree closely with the curves obtained using the experimental method. In addition, the maximum press-mounting force calculated by FEA agrees with that obtained by the experimental method, with the maximum deviation being 4.6%, a value that can be tolerated. The comparison shows that the press-fit curve and max press-mounting force calculated by FEA can be used for predicting the pressing quality during precision press-fit assembly.

  5. Reciprocating pellet press

    Science.gov (United States)

    Jones, Charles W.

    1981-04-07

    A machine for pressing loose powder into pellets using a series of reciprocating motions has an interchangeable punch and die as its only accurately machines parts. The machine reciprocates horizontally between powder receiving and pressing positions. It reciprocates vertically to press, strip and release a pellet.

  6. The Global University Press

    Science.gov (United States)

    Dougherty, Peter J.

    2012-01-01

    The modern world's understanding of American university press has long been shaped by university-press books. American university-press books are good international advertisements for the universities whose logos grace their spines. The growth of transnational scholarship and the expansion of digital communications networks are converging in ways…

  7. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    Science.gov (United States)

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model

  8. Structure and hardness of TiAl-TiB2 composite prepared by hot isostatic pressing of mechanically alloyed powders. Mekanikaru aroingu funmatsu no HIP shoketsu ni yori sakuseishita TiAl/TiB2 fukugo zairyo no soshiki to kodo

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T; Shimakage, K [Muroran Inst. of Technology, Hokkaido (Japan). Faculty of Engineering; Miyakawa, S [Muroran Inst. of Technology, Hokkaido (Japan). Graduate Student

    1992-11-20

    The practical application of Ti-Al system intermetallic compounds is expected as an advanced light heat resistant material. TiAl group out of them, as for the specific strength, has an equivalent maximum working temperature as that of the nickel base alloy, which is utilized as a turbine material for the current aircraft, and moreover it is also said that it is superior in the creep and rupture properties to the latter. In this study, by mechanical alloying (MA) of each mixed powder of Ti-Al and Ti-B, by suing heptane as a grinding aid, each MA powder of the amorphous TiAl containing carbon and extremely fine compound TiB2 were prepared, and subsequently the true density sintering by the hot isostatic pressing (HIP) was performed, and by doing these, the preparation of TiAl/TiB2 system composite material with a high composite ratio of TiO2 was tried. Consequently, by the MA treatment of the mixed powder of Ti and B for more than 50 hours, the compound powder of TiB2 mixed with TiB could be prepared, and its hardness has shown the maximum value Hmv=l200 with a composition of TiAl/25 mol % TiB2. 14 refs., 10 figs., 2 tabs.

  9. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, Nicolaas Jacobus Joseph; van Susante, J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  10. "Deeper than Rap": Gifted Males and Their Relationship with Hip Hop Culture

    Science.gov (United States)

    Callahan, J. Sean; Grantham, Tarek C.

    2012-01-01

    One would be hard-pressed to deny the impact that hip hop is having on gifted students. More specifically, because hip hop is a creative and exciting male-dominated culture, gifted males gravitate to hip hop culture. From the perspective of two Black men from two different generations, this article was inspired by discussions about the role of hip…

  11. WordPress Bible

    CERN Document Server

    Brazell, Aaron

    2010-01-01

    The WordPress Bible provides a complete and thorough guide to the largest self hosted blogging tool. This guide starts by covering the basics of WordPress such as installing and the principles of blogging, marketing and social media interaction, but then quickly ramps the reader up to more intermediate to advanced level topics such as plugins, WordPress Loop, themes and templates, custom fields, caching, security and more. The WordPress Bible is the only complete resource one needs to learning WordPress from beginning to end.

  12. Hip Injuries and Disorders

    Science.gov (United States)

    Your hip is the joint where your femur (thigh bone) meets your pelvis (hip bone). There are two main parts: a ball ... fits in a socket in the pelvis. Your hip is known as a ball-and-socket joint. ...

  13. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  14. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  15. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    Science.gov (United States)

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Trajectory of social isolation following hip fracture: an analysis of the English Longitudinal Study of Ageing (ELSA) cohort.

    Science.gov (United States)

    Smith, Toby O; Dainty, Jack R; MacGregor, Alex

    2018-01-01

    social isolation is defined as a lack of meaningful and sustained communication or interactions with social networks. There is limited understanding on the prevalence of social isolation and loneliness in people following hip fracture and no previous understanding of how this changes over time. to determine the prevalence and trajectory of social isolation and loneliness before a hip fracture, during the recovery phase and a minimum of 2 years post-hip fracture in an English population. data were from the English Longitudinal Study of Ageing (ELSA) cohort (2004/5-2014/15). The sample comprised of 215 participants who had sustained a hip fracture. Measures of social isolation and loneliness were analysed through multilevel modelling to determine their trajectories during three-time intervals (pre-fracture; interval at hip fracture and recovery; minimum 2 years post-fracture). The prevalence of social isolation and loneliness were determined pre- and post-fracture. prevalence of social isolation was 19% post-hip fracture and loneliness 13% post-hip fracture. There was no statistically significant change in social isolation pre-fracture compared to a minimum of 2 years post-fracture (P = 0.78). Similarly, there was no statistically significant change in loneliness pre-fracture compared to a minimum of 2 years post-fracture (P = 0.12). this analysis has determined that whilst social isolation and loneliness do not change over time following hip fracture, these remain a significant problem for this population. Interventions are required to address these physical and psychological health needs. This is important as they may have short and longer term health benefits for people post-hip fracture. © The Author 2017. Published by Oxford University Press on behalf of the British Geriatrics Society.All rights reserved. For permissions, please email: journals.permissions@oup.com

  17. Encapsulation of krypton-85 in zeolite molecular sieve with a hot isostatic press

    International Nuclear Information System (INIS)

    Christensen, A.B.; DelDebbio, J.A.; Knecht, D.A.; Tanner, J.E.

    1986-01-01

    This paper describes pilot and full-scale experiments which demonstrated the feasibility of immobilizing Kr-85 in a zeolite 5A/glass mixture and compacting it before disposal. The full volume of a one-liter hot isostatic press (HIP) was used to trap argon in zeolite 5A. For radioactive krypton the HIP was modified to isolate the Kr-85 in the work zone. Details of the HIP modifications, experimental procedure, and sample analysis are reported

  18. The use of the greater trochanter marker in the thigh segment model: Implications for hip and knee frontal and transverse plane motion

    Directory of Open Access Journals (Sweden)

    Valentina Graci

    2016-03-01

    Conclusion: Hip and knee kinematics differed across different segment definitions including or excluding the greater trochanter marker, especially in the transverse plane. Therefore when considering whether to include the greater trochanter in the thigh segment model when using a surface markers to calculate 3D kinematics for movement assessment, it is important to have a clear understanding of the effect of different marker sets and segment models in use.

  19. A 3D musculoskeletal model of the western lowland gorilla hind limb: moment arms and torque of the hip, knee and ankle

    OpenAIRE

    Goh, Colleen; Blanchard, Mary L.; Crompton, Robin H.; Gunther, Michael M.; Macaulay, Sophie; Bates, Karl T.

    2017-01-01

    Abstract Three?dimensional musculoskeletal models have become increasingly common for investigating muscle moment arms in studies of vertebrate locomotion. In this study we present the first musculoskeletal model of a western lowland gorilla hind limb. Moment arms of individual muscles around the hip, knee and ankle were compared with previously published data derived from the experimental tendon travel method. Considerable differences were found which we attribute to the different methodolog...

  20. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    Science.gov (United States)

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (Pcup coverage (Pearson r=0.761, Pcup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  1. ValuedCare program: a population health model for the delivery of evidence-based care across care continuum for hip fracture patients in Eastern Singapore.

    Science.gov (United States)

    Mittal, Chikul; Lee, Hsien Chieh Daniel; Goh, Kiat Sern; Lau, Cheng Kiang Adrian; Tay, Leeanna; Siau, Chuin; Loh, Yik Hin; Goh, Teck Kheng Edward; Sandi, Chit Lwin; Lee, Chien Earn

    2018-05-30

    To test a population health program which could, through the application of process redesign, implement multiple evidence-based practices across the continuum of care in a functionally integrated health delivery system and deliver highly reliable and consistent evidence-based surgical care for patients with fragility hip fractures in an acute tertiary general hospital. The ValuedCare (VC) program was developed in three distinct phases as an ongoing collaboration between the Geisinger Health System (GHS), USA, and Changi General Hospital (CGH), Singapore, modelled after the GHS ProvenCare® Fragile Hip Fracture Program. Clinical outcome data on consecutive hip fracture patients seen in 12 months pre-intervention were then compared with the post-intervention group. Both pre- and post-intervention groups were followed up across the continuum of care for a period of 12 months. VC patients showed significant improvement in median time to surgery (97 to 50.5 h), as well as proportion of patients operated within 48 h from hospital admission (48% from 18.8%) as compared to baseline pre-intervention data. These patients also had significant reduction (p value based care for hip fracture patients at Changi General Hospital. This has also reflected successful change management and interdisciplinary collaboration within the organization through the program. There is potential for testing this methodology as a quality improvement framework replicable to other disease groups in a functionally integrated healthcare system.

  2. Hot-pressed geopolymer

    DEFF Research Database (Denmark)

    Ranjbar, Navid; Mehrali, Mohammad; Maheri, Mahmoud R.

    2017-01-01

    This research explores the use of simultaneous heating and pressing techniques in order to enhance the mechanical properties of fly ash (FA) based geopolymer under relatively low temperature conditions to ensure minimum-porosity. Four effective parameters of pressing force, alkali activator...

  3. Should All Patients Be Included in Alternative Payment Models for Primary Total Hip Arthroplasty and Total Knee Arthroplasty?

    Science.gov (United States)

    Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin

    2016-09-01

    Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Economic viability of geriatric hip fracture centers.

    Science.gov (United States)

    Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph

    2013-12-01

    Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers.

  5. FeCrAl and Zr alloys joined using hot isostatic pressing for fusion energy applications

    International Nuclear Information System (INIS)

    Park, Dong Jun; Kim, Hyun Gil; Park, Jeong Yong; Jung, Yang Il; Park, Jung Hwan; Koo, Yang Hyun

    2016-01-01

    Highlights: • FeCrAl and Zr alloys were successfully joined by hot isostatic pressing (HIP). • The thickness of diffusion layer increased with an increase in HIP temperature. • Significant inter-diffusion was observed for HIP at 1150 °C. • Maximum joint strength was achieved at HIP temperature of 700 °C. - Abstract: FeCrAl and Zr alloys were joined by a hot isostatic pressing (HIP) method for fusion energy applications. The optimum conditions for the joining process were studied. The HIP temperatures were varied from 700 to 1050 °C. The mechanical properties of the HIPed samples were evaluated by four-point bending and tensile tests. The FeCrAl and Zr alloys HIPed at 700 °C showed higher joint strength than the other samples. The joint strength decreased with an increase in the HIP temperature from 700 to 950 °C and significantly dropped at 1050 °C. Transmission electron microscopy, scanning electron microscopy, and optical microscopy were used to characterize the joints and interface region of the HIPed samples. The joints appeared to be tightly bonded and no intermetallic compounds or gaps were observed at the interface for HIP temperatures up to 950 °C. A diffusion layer formed at the interface and its thickness increased with the HIP temperature. HIP at 1050 °C, on the other hand, resulted in significant inter-diffusion and formation of brittle inter-metallic compounds at the interface.

  6. Designing a Care Pathway Model – A Case Study of the Outpatient Total Hip Arthroplasty Care Pathway

    Directory of Open Access Journals (Sweden)

    Robin I. Oosterholt

    2017-03-01

    Full Text Available Introduction: Although the clinical attributes of total hip arthroplasty (THA care pathways have been thoroughly researched, a detailed understanding of the equally important organisational attributes is still lacking. The aim of this article is to contribute with a model of the outpatient THA care pathway that depicts how the care team should be organised to enable patient discharge on the day of surgery. Theory: The outpatient THA care pathway enables patients to be discharged on the day of surgery, short- ening the length of stay and intensifying the provision and organisation of care. We utilise visual care modelling to construct a visual design of the organisation of the care pathway. Methods: An embedded case study was conducted of the outpatient THA care pathway at a teaching hospital in the Netherlands. The data were collected using a visual care modelling toolkit in 16 semi- structured interviews. Problems and inefficiencies in the care pathway were identified and addressed in the iterative design process. Results: The results are two visual models of the most critical phases of the outpatient THA care pathway: diagnosis & preparation (1 and mobilisation & discharge (4. The results show the care team composition, critical value exchanges, and sequence that enable patient discharge on the day of surgery. Conclusion: The design addressed existing problems and is an optimisation of the case hospital’s pathway. The network of actors consists of the patient (1, radiologist (1, anaesthetist (1, nurse specialist (1, pharmacist (1, orthopaedic surgeon (1,4, physiotherapist (1,4, nurse (4, doctor (4 and patient applica- tion (1,4. The critical value exchanges include patient preparation (mental and practical, patient education, aligned care team, efficient sequence of value exchanges, early patient mobilisation, flexible availability of the physiotherapist, functional discharge criteria, joint decision making and availability of the care team.

  7. Process and equipment development for hot isostatic pressing treatability study

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, Ken; Wahlquist, Dennis; Malewitz, Tim

    2015-03-01

    Battelle Energy Alliance (BEA), LLC, has developed processes and equipment for a pilot-scale hot isostatic pressing (HIP) treatability study to stabilize and volume reduce radioactive calcine stored at Idaho National Laboratory (INL). In 2009, the U. S. Department of Energy signed a Record of Decision with the state of Idaho selecting HIP technology as the method to treat 5,800 yd^3 (4,400 m^3) of granular zirconia and alumina calcine produced between 1953 and 1992 as a waste byproduct of spent nuclear fuel reprocessing. Since the 1990s, a variety of radioactive and hazardous waste forms have been remotely treated using HIP within INL hot cells. To execute the remote process at INL, waste is loaded into a stainless-steel or aluminum can, which is evacuated, sealed, and placed into a HIP furnace. The HIP simultaneously heats and pressurizes the waste, reducing its volume and increasing its durability. Two 1 gal cans of calcine waste currently stored in a shielded cask were identified as candidate materials for a treatability study involving the HIP process. Equipment and materials for cask-handling and calcine transfer into INL hot cells, as well as remotely operated equipment for waste can opening, particle sizing, material blending, and HIP can loading have been designed and successfully tested. These results demonstrate BEA’s readiness for treatment of INL calcine.

  8. Electro-thermal Modeling for Junction Temperature Cycling-Based Lifetime Prediction of a Press-Pack IGBT 3L-NPC-VSC Applied to Large Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Munk-Nielsen, Stig; Teodorescu, Remus

    2011-01-01

    Reliability is a critical criterion for multi-MW wind turbines, which are being employed with increasing numbers in wind power plants, since they operate under harsh conditions and have high maintenance cost due to their remote locations. In this study, the wind turbine grid-side converter...... reliability is investigated regarding IGBT lifetime based on junction temperature cycling for the grid-side press-pack IGBT 3L-NPC-VSC, which is a state-of-the art high reliability solution. In order to acquire IGBT junction temperatures for given wind power profiles and to use them in IGBT lifetime...... prediction, the converter electro-thermal model including electrical, power loss, and dynamical thermal models is developed with the main focus on the thermal modeling regarding converter topology, switch technology, and physical structure. Moreover, these models are simplified for their practical...

  9. Patterns of subcutaneous fat deposition and the relationship between body mass index and waist-to-hip ratio: implications for models of physical attractiveness.

    Science.gov (United States)

    Cornelissen, Piers L; Toveé, Martin J; Bateson, Melissa

    2009-02-07

    Body mass index (BMI) and waist-to-hip ratio (WHR) are two widely used anthropometric indices of body shape argued to convey different information about health and fertility. Both indices have also been shown to affect attractiveness ratings of female bodies. However, BMI and WHR are naturally positively correlated, complicating studies designed to identify their relative importance in predicting health and attractiveness outcomes. We show that the correlation between BMI and WHR depends on the assumed model of subcutaneous fat deposition. An additive model, whereby fat is added to the waist and hips at a constant rate, predicts a correlation between BMI and WHR because with increasing fat, the difference between the waist and hips becomes smaller relative to total width. This model is supported by longitudinal and cross-sectional data. We parameterized the function relating WHR to BMI for white UK females of reproductive age, and used this function to statistically decompose body shape into two independent components. We show that judgements of the attractiveness of female bodies are well explained by the component of curvaceousness related to BMI but not by residual curvaceousness. Our findings resolve a long-standing dispute in the attractiveness literature by confirming that although WHR appears to be an important predictor of attractiveness, this is largely explained by the direct effect of total body fat on WHR, thus reinforcing the conclusion that total body fat is the primary determinant of female body shape attractiveness.

  10. WordPress Bible

    CERN Document Server

    Brazell, Aaron

    2011-01-01

    Get the latest word on the biggest self-hosted blogging tool on the marketWithin a week of the announcement of WordPress 3.0, it had been downloaded over a million times. Now you can get on the bandwagon of this popular open-source blogging tool with WordPress Bible, 2nd Edition. Whether you're a casual blogger or programming pro, this comprehensive guide covers the latest version of WordPress, from the basics through advanced application development. If you want to thoroughly learn WordPress, this is the book you need to succeed.Explores the principles of blogging, marketing, and social media

  11. HIP JOINT AND HIP ENDOPROSTHESIS BIOMECHANICS

    OpenAIRE

    Jakub Gryka

    2017-01-01

    This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.

  12. Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard.

    Science.gov (United States)

    Wu, R H; Lin, R; Li, H; Xiao, Z W; Rao, H B; Luo, W H; Guo, G; Huang, K; Zhang, X G; Lang, Z J

    2005-01-01

    The metabolite ratios had been employed in the field of MR spectroscopy (MRS) for a long period. The main drawback of metabolite ratio is that ratio results are not comparable with absolute metabolite concentration in vivo. The purpose of this study was to examine the accuracy of noninvasive quantification of brain N-acetylaspartate (NAA) concentrations using previously reported MR external standard method. Eight swine were scanned on a GE 1.5 T scanner with a standard head coil. The external standard method was utilized with a sphere filled with NAA, GABA, glutamine, glutamate, creatine, choline chloride, and myo-inositol. The position resolved spectroscopy (PRESS) sequence was used with TE=135 msec, TR=1500 msec, and 128 scan averages. The analysis of MRS was done with SAGE/IDL program. In vivo NAA concentration was obtained using the equation S=N * e(-TE/T2) * [1-e(-TR/T1). In vitro NAA concentration was measured by high performance liquid chromatography (HPLC). In the MRS group, the mean concentration of NAA was 10.03 plusmn 0.74 mmol/kg. In the HPLC group, the mean concentration of NAA was 9.22 plusmn 0.55 mmol/kg. There was no significant difference between the two groups (p = 0.46). However, slightly higher value was observed in the MRS group (7/8 swine), compared with HPLC group. The range of differences was between 0.02~2.05 mmol/kg. MRS external reference method could be more accurate than internal reference method. 1H MRS does not distinguish between N-acetyl resonance frequencies and other N-acetylated amino acids.

  13. Two layer powder pressing

    International Nuclear Information System (INIS)

    Schreiner, H.

    1979-01-01

    First, significance and advantages of sintered materials consisting of two layers are pointed out. By means of the two layer powder pressing technique metal powders are formed resulting in compacts with high accuracy of shape and mass. Attributes of basic powders, different filling methods and pressing techniques are discussed. The described technique is supposed to find further applications in the field of two layer compacts in the near future

  14. The TARGET project in Tuscany: the first disease management model of a regional project for the prevention of hip re-fractures in the elderly.

    Science.gov (United States)

    Piscitelli, Prisco; Brandi, Maria Luisa; Nuti, Ranuccio; Rizzuti, Carla; Giorni, Loredano; Giovannini, Valtere; Metozzi, Alessia; Merlotti, Daniela

    2010-09-01

    The official inquiry on osteoporosis in Italy, promoted by the Italian Senate in 2002 concluded that proper preventive strategies should be adopted at regional level in order to prevent osteoporotic fractures. Tuscany is the first Italian region who has promoted an official program (the TARGET project) aimed to reduce osteoporotic fractures by ensuring adequate treatment to all people aged ≥65 years old who experience a hip fragility fracture. this paper provides information concerning the implementation of TARGET project in Tuscany, assuming that it may represent an useful model for similar experiences to be promoted in other Italian Regions and across Europe. we have examined the model proposed for the regional program, and we have particularly analyzed the in-hospital and post-hospitalization path of hip fractured patients aged >65 years old in Tuscany after the adoption of TARGET project by Tuscany healthcare system and during its ongoing start-up phase. orthopaedic surgeons have been gradually involved in the project and are increasingly fulfilling all the clinical prescriptions and recommendations provided in the project protocol. Different forms of cooperation between orthopaedic surgeons and other clinical specialists have been adopted at each hospital for the treatment of hip fractured elderly patients. GPs involvement needs to be fostered both at regional and local level. The effort of Tuscany region to cope with hip fractures suffered from elderly people must be acknowledged as an interesting way of addressing this critical health problem. Specific preventive strategies modelled on the Tuscany TARGET project should be implemented in other Italian regions.

  15. The association between eccentric hip abduction strength and hip and knee angular movements in recreational male runners

    DEFF Research Database (Denmark)

    Brund, René B. Korsgaard; Rasmussen, Sten; Nielsen, Rasmus O.

    2018-01-01

    Weak hip abductors may be related with increased hip adduction and knee abduction angular movement, which may be risk factors of lower extremity injuries. As the role of eccentric hip abduction strength (EHAS) on hip adduction angular movement and knee abduction angular movement (KABD) remains...... and Codamotion active marker system. Using multiple linear regression models (n=186 legs), no relationships between EHAS and hip and knee kinematics were found. A possible reason for the lack of relationship between EHAS and hip and knee kinematics may be owing to differences in the running kinematics. Some...

  16. Densification of boron carbide at relatively low temperatures by hot pressing and hot isostatic pressing

    International Nuclear Information System (INIS)

    Telle, R.

    1988-01-01

    The poor sinterability of B 4 C limits its widespread application because both high temperatures and high pressures are required for a complete densification. Moreover, B 4 C suffers from a low strength and fracture toughness, possesses, however, a high potential because of its extreme hardness. Reaction hot pressing of B 4 C-WC-TiC-Si-Co mixtures resulting in B 4 C-TiB 2 -W 2 B 5 composites of high density exhibit remarkable mechanical properties. The influence of hot isostatic pressing (HIP) on the microstructure and the mechanical properties is investigated in cooperation with participants of the COST 503 activities and related to the strengthening and toughening mechanisms. Difficulties during densification by HIP arise from the evaporation of adsorbed volatiles as well as from the strong swelling of the powder compact due to the sintering reaction. Several HIP cycle designs were tested in order to prevent the bloating of the capsule and to control internal stresses due to the misfit of the thermal expansion of the entire phases. In comparison to single phase B 4 C ceramics, bending strength was improved to 1030 MPa, K Ic to 5.2 MPa/m, while hardness was comparable with HV1=38 GPa. Wear test were performed and related to the toughening mechanisms. (orig.) With 56 refs., 9 tabs., 64 figs

  17. How to Find Optimal National Model of Pension System: the Projection on Russia (Book Review: Barr, N. Pension reform: A short guide [Text] / N. Barr, P. Diamond. – Oxford : Oxford University Press, 2010. – 261 p.

    Directory of Open Access Journals (Sweden)

    Karen Avakovich Tumanyants

    2015-12-01

    Full Text Available How to Find Optimal National Model of Pension System: the Projection on Russia (Book Review: Barr, N. Pension reform: A short guide [Text] / N. Barr, P. Diamond. – Oxford : Oxford University Press, 2010. – 261 p.

  18. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  19. Validation of hamstrings musculoskeletal modeling by calculating peak hamstrings length at different hip angles

    NARCIS (Netherlands)

    van der Krogt, M.M.; Doorenbosch, C.A.M.; Harlaar, J.

    2008-01-01

    Accurate estimates of hamstrings lengths are useful, for example, to facilitate planning for surgical lengthening of the hamstrings in patients with cerebral palsy. In this study, three models used to estimate hamstrings length (M1: Delp, M2: Klein Horsman, M3: Hawkins and Hull) were evaluated. This

  20. A model-based approach to stabilizing crutch supported paraplegic standing by artifical hip joint stiffness

    NARCIS (Netherlands)

    van der Spek, J.H.; Veltink, Petrus H.; Hermens, Hermanus J.; Koopman, Hubertus F.J.M.; Boom, H.B.K.

    2003-01-01

    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position

  1. Model-driven harmonic parameterization of the cortical surface: HIP-HOP.

    Science.gov (United States)

    Auzias, G; Lefèvre, J; Le Troter, A; Fischer, C; Perrot, M; Régis, J; Coulon, O

    2013-05-01

    In the context of inter subject brain surface matching, we present a parameterization of the cortical surface constrained by a model of cortical organization. The parameterization is defined via an harmonic mapping of each hemisphere surface to a rectangular planar domain that integrates a representation of the model. As opposed to previous landmark-based registration methods we do not match folds between individuals but instead optimize the fit between cortical sulci and specific iso-coordinate axis in the model. This strategy overcomes some limitation to sulcus-based registration techniques such as topological variability in sulcal landmarks across subjects. Experiments on 62 subjects with manually traced sulci are presented and compared with the result of the Freesurfer software. The evaluation involves a measure of dispersion of sulci with both angular and area distortions. We show that the model-based strategy can lead to a natural, efficient and very fast (less than 5 min per hemisphere) method for defining inter subjects correspondences. We discuss how this approach also reduces the problems inherent to anatomically defined landmarks and open the way to the investigation of cortical organization through the notion of orientation and alignment of structures across the cortex.

  2. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  3. Hip joint replacement - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  4. Hip Labral Tear

    Science.gov (United States)

    ... that joint in the future. Prevention Hip labral tears are often associated with sports participation. If your sport puts a lot of strain on your hips, condition the surrounding muscles with strength and flexibility exercises. Try to avoid ...

  5. Binary classification of dyslipidemia from the waist-to-hip ratio and body mass index: a comparison of linear, logistic, and CART models

    Directory of Open Access Journals (Sweden)

    Paccaud Fred

    2004-04-01

    Full Text Available Abstract Background We sought to improve upon previously published statistical modeling strategies for binary classification of dyslipidemia for general population screening purposes based on the waist-to-hip circumference ratio and body mass index anthropometric measurements. Methods Study subjects were participants in WHO-MONICA population-based surveys conducted in two Swiss regions. Outcome variables were based on the total serum cholesterol to high density lipoprotein cholesterol ratio. The other potential predictor variables were gender, age, current cigarette smoking, and hypertension. The models investigated were: (i linear regression; (ii logistic classification; (iii regression trees; (iv classification trees (iii and iv are collectively known as "CART". Binary classification performance of the region-specific models was externally validated by classifying the subjects from the other region. Results Waist-to-hip circumference ratio and body mass index remained modest predictors of dyslipidemia. Correct classification rates for all models were 60–80%, with marked gender differences. Gender-specific models provided only small gains in classification. The external validations provided assurance about the stability of the models. Conclusions There were no striking differences between either the algebraic (i, ii vs. non-algebraic (iii, iv, or the regression (i, iii vs. classification (ii, iv modeling approaches. Anticipated advantages of the CART vs. simple additive linear and logistic models were less than expected in this particular application with a relatively small set of predictor variables. CART models may be more useful when considering main effects and interactions between larger sets of predictor variables.

  6. Power Capability Investigation Based on Electrothermal Models of Press-pack IGBT Three-Level NPC and ANPC VSCs for Multimegawatt Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2012-01-01

    to provide reactive power support as an ancillary service. For multimegawatt full-scale wind turbines, power capability depends on converter topology and semiconductor switch technology. As power capability limiting factors, switch current, semiconductor junction temperature, and converter output voltage...... are addressed in this study for the three-level neutral-point-clamped voltage source converter (3L-NPC-VSC) and 3L Active NPC VSC (3L-ANPC-VSC) with press-pack insulated gate bipolar transistors employed as a grid-side converter. In order to investigate these VSCs' power capabilities under various operating...... conditions with respect to these limiting factors, a power capability generation algorithm based on the converter electrothermal model is developed. Built considering the VSCs' operation principles and physical structure, the model is validated by a 2 MV·A single-phase 3L-ANPC-VSC test setup. The power...

  7. HPLC/DAD Intercomparison on Phytoplankton Pigments (HIP-1, HIP-2, HIP-3 and HIP-4)

    OpenAIRE

    CANUTI Elisabetta; RAS Josephine; GRUNG Merete; ROTTGERS Rudiger; COSTA GOELA Priscilla; ARTUSO Florinda; CATALDI Dario

    2016-01-01

    From 2009 to 2015, in the context of the MERIS (Medium Resolution Imaging Spectrometer) validation activities, the JRC Marine Optical Laboratory organised four HPLC Intercomparison exercises for Phytoplankton Pigment measurements (HIP-1, HIP-2, HIP-3 and HIP-4), involving seven European accredited and reference laboratories. The objectives of these intercomparison exercises were: creating a reference community at European level for phytoplankton pigment analysis capable of supporting satel...

  8. TREATMENT OF HIP DYSPLASIA

    OpenAIRE

    Iulian ICLEANU; Mariana CORDUN

    2015-01-01

    In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (g...

  9. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  10. Bursitis of the Hip

    Science.gov (United States)

    ... difficile (C. diff.) InfectionHerpes Home Diseases and Conditions Bursitis of the Hip Condition Bursitis of the Hip Share Print Table of Contents1. ... Prevention5. Treatment6. Everyday Life7. Questions8. Resources What is bursitis of the hip? Bursitis is the painful swelling ...

  11. HIPs at Ten

    Science.gov (United States)

    Kuh, George; O'Donnell, Ken; Schneider, Carol Geary

    2017-01-01

    2017 is the anniversary of the introduction of what are now commonly known as high-impact practices (HIPs). Many of the specific activities pursued under the HIPs acronym have been around in some form for decades, such as study abroad, internships, and student-faculty research. It was about ten years ago that, after conferring HIPs at Ten with…

  12. Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model

    Directory of Open Access Journals (Sweden)

    Gregor Hauschild

    2015-01-01

    Full Text Available Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (megaprostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition- silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses.

  13. Evaluation of osseous integration of PVD-silver-coated hip prostheses in a canine model.

    Science.gov (United States)

    Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Stoeppeler, Sandra; Ahrens, Helmut; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen

    2015-01-01

    Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses.

  14. Cementless Hydroxyapatite Coated Hip Prostheses

    Science.gov (United States)

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  15. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  16. ALUMINUM BOX BUNDLING PRESS

    Directory of Open Access Journals (Sweden)

    Iosif DUMITRESCU

    2015-05-01

    Full Text Available In municipal solid waste, aluminum is the main nonferrous metal, approximately 80- 85% of the total nonferrous metals. The income per ton gained from aluminum recuperation is 20 times higher than from glass, steel boxes or paper recuperation. The object of this paper is the design of a 300 kN press for aluminum box bundling.

  17. DSS / Press Room

    Science.gov (United States)

    Defense Security Service, U.S. Department of Defense Site Map | A-Z Index | Facebook | Twitter Locations Press Room Organizational Structure Careers at DSS Doing Business with DSS Frequently Asked Classification System (NCCS) National Industrial Security System (NISS) ODAA Business Management System (OBMS

  18. OAS :: Press Releases

    Science.gov (United States)

    subscriptions Videos Photos Live Webcast Social Media Facebook @oasofficial Facebook Twitter @oas_official Social Media Facebook Twitter Newsletters Press and Communications Department Contact us at: +1 (202) 370 Rights Actions against Corruption C Children Civil Registry Civil Society Contact Us Culture Cyber

  19. bbPress complete

    CERN Document Server

    Wynne, Rhys

    2013-01-01

    A concise guide, written in an easy-to-follow format.This book is aimed at ambitious website or blog owners looking to add a forum to their site quickly and easily. Basic experience in WordPress and with managing a website is expected. Knowledge of HTML and PHP will be a bonus, though it isn't necessary.

  20. Tantalum powder consolidation, modeling and properties

    International Nuclear Information System (INIS)

    Bingert, S.R.; Vargas, V.D.; Sheinberg, H.C.

    1996-01-01

    A systematic approach was taken to investigate the consolidation of tantalum powders. The effects of sinter time, temperature and ramp rate; hot isostatic pressing (HIP) temperature and time; and powder oxygen content on consolidation density, kinetics, microstructure, crystallographic texture, and mechanical properties have been evaluated. In general, higher temperatures and longer hold times resulted in higher density compacts with larger grain sizes for both sintering and HIP'ing. HIP'ed compacts were consistently higher in density than sintered products. The higher oxygen content powders resulted in finer grained, higher density HIP'ed products than the low oxygen powders. Texture analysis showed that the isostatically processed powder products demonstrated a near random texture. This resulted in isotropic properties in the final product. Mechanical testing results showed that the HIP'ed powder products had consistently higher flow stresses than conventionally produced plates, and the sintered compacts were comparable to the plate material. A micromechanics model (Ashby HIP model) has been employed to predict the mechanisms active in the consolidation processes of cold isostatic pressing (CIP), HIP and sintering. This model also predicts the density of the end product and whether grain growth should be expected under the applied processing conditions

  1. Family and family education model in parish press of Great Poland in 2 Polish Republic: „Tygodnik Parafji Zbąszynskiej” example

    Directory of Open Access Journals (Sweden)

    MIROSŁAW PIWOWARCZYK

    2017-10-01

    Full Text Available Local press played a significant role in 2nd Polish Republic both from the perspective if state administration, territorial autonomies, political parties and the expectations of wide social environments and local communities. It fulfilled the need of information on the social, political, educational, cultural and economical life of specific environments. It also worked as a tool in propaganda and political agitation, it familiarized ideologies of political parties and expressed views and idea of local communities. It played an important part in local economy life; it educated and actively took part in popularization of interests in regional issues.Local press was both: amirror of contemporary social relations, political and national divisions and the important agent in initiatives such as cultural events. It registered and pictured life of the town and its area citizens, gave pedagogical impact on the young generation by giving them patterns and forms of positive social actions, popularized specific ideologies, educational concepts, patterns of behavior, it created and influenced the local communities attitudes and actions. Its role was especially visible in Great Poland, where local press helped in creation of socio-cultural life in small towns and education. In the group of magazines that specifically influenced local communities cultural character and had an important educational impact we should (undoubtedly include the parish press. Parish magazines in many cases played a role of the local community press. Beside the information on the church and parish community problems they included a lot of news from the life of the town and its area; they constituted a chronicle of local community events and also propagated precise world-view and coherent with it concepts oft. It was a case in Zbąszyń, were was published. played a sagnificant educational role in its environment. It propagated a homogenus, stright forward perspective (concept of

  2. Hot-isostatic pressing of U-10Zr by grain boundary diffusion and creep cavitation. Part 2: Theory and data analysis

    International Nuclear Information System (INIS)

    McDeavitt, S.M.; Solomon, A.A.

    1997-01-01

    Uranium-10 wt % zirconium (U-10Zr) is a fuel alloy that has been used in the Experimental Breeder Reactor-II (EBR-II). The high burnup that was desired in this fuel system made high demands on the mechanical compatibility between fuel and cladding both during normal operation and during safety-related transients when rapid differential expansion may cause high stresses. In general, this mechanical stress can be reduced by cladding deformation if the cladding is sufficiently ductile at high burnup, and/or by fuel hot-pressing. Fortunately, the fuel is very porous when it contacts the cladding, but this porosity gradually fills with solid fission products (primarily lanthanides) that may limit the fuel's compressibility. If the porosity remains open, gaseous fission products are released and the porous fuel creeps rather than hot-presses under contact stresses. If the pores are closed by sintering or by solid fission products, the porous fuel will hot-isostatic press (HIP), as represented by the models to be discussed. HIP experiments performed at 700 C on U-10Zr samples with different impurity phase contents (Part 1) are analyzed in terms of several creep cavitation models. The coupled diffusion/creep cavitation model of Chen and Argon shows good quantitative agreement with measured HIP rates for hydride- and metal-derived U-10Zr materials, assuming that pores are uniformly distributed on grain boundaries and are of modal size, and that far-field strain rates are negligible. The analysis predicts, for the first time, an asymmetry between HIP and swelling at identical pressure-induced driving forces due to differences in grain boundary stresses. The differences in compressibility of hydride- and metal-derived U-10Zr can be partially explained by differences in pore size and spacing. The relevance of the experiments to description of in-reactor densification under external pressure or contact stress due to fuel/cladding mechanical interaction is discussed

  3. Hip Resurfacing: An Alternative to Conventional Hip Replacement?

    Science.gov (United States)

    ... Is hip resurfacing a good alternative to hip replacement? Answers from Mark Spangehl, M.D. Hip resurfacing has lost favor with many surgeons ... women with poor bone quality. Unlike traditional hip replacement, hip resurfacing doesn't completely replace the "ball" ...

  4. A 3D musculoskeletal model of the western lowland gorilla hind limb: moment arms and torque of the hip, knee and ankle.

    Science.gov (United States)

    Goh, Colleen; Blanchard, Mary L; Crompton, Robin H; Gunther, Michael M; Macaulay, Sophie; Bates, Karl T

    2017-10-01

    Three-dimensional musculoskeletal models have become increasingly common for investigating muscle moment arms in studies of vertebrate locomotion. In this study we present the first musculoskeletal model of a western lowland gorilla hind limb. Moment arms of individual muscles around the hip, knee and ankle were compared with previously published data derived from the experimental tendon travel method. Considerable differences were found which we attribute to the different methodologies in this specific case. In this instance, we argue that our 3D model provides more accurate and reliable moment arm data than previously published data on the gorilla because our model incorporates more detailed consideration of the 3D geometry of muscles and the geometric constraints that exist on their lines-of-action about limb joints. Our new data have led us to revaluate the previous conclusion that muscle moment arms in the gorilla hind limb are optimised for locomotion with crouched or flexed limb postures. Furthermore, we found that bipedalism and terrestrial quadrupedalism coincided more regularly with higher moment arms and torque around the hip, knee and ankle than did vertical climbing. This indicates that the ability of a gorilla to walk bipedally is not restricted by musculoskeletal adaptations for quadrupedalism and vertical climbing, at least in terms of moment arms and torque about hind limb joints. © 2017 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  5. Myths About Press Freedom

    Directory of Open Access Journals (Sweden)

    Kaarle Nordenstreng

    2007-06-01

    Full Text Available This article intends to rectify three popular beliefs related to press freedom: (1 that the idea of a free marketplace of ideas with a self-righting truth belongs to original liberalism, (2 that UNESCO’s primary mission is to promote freedom of information, and (3 that the Universal Declaration of Human Rights provides legal safeguards for the media. These beliefs are shown, on the basis of the legacy of liberalism and documents of the international community, to be misleading myths. Instead of accurate readings of the idea of freedom, they serve as ideological positions which are harmful to democracy. The Millennium Declaration provides further proof that the international community has a much more balanced view of freedom of information than that typically held by media professionals. Therefore it is important to liberate the concept of press freedom from its ideological baggage.

  6. Vacuum hot pressing of titanium-alloy powders

    International Nuclear Information System (INIS)

    Malik, R.K.

    1975-01-01

    Full or nearly full dense products of wrought-metal properties have been obtained by vacuum hot pressing (VHP) of several prealloyed Ti--6Al--4V powders including hydride, hydride/dehydride, and rotating electrode process (REP) spherical powder. The properties of billets VHP from Ti--6Al--4V hydride powder and from hydride/dehydride powders have been shown to be equivalent. The REP spherical powder billets processed by VHP or by hot isostatic pressing (HIP) resulted in equivalent tensile properties. The potential of VHP for fabrication of near net aircraft parts such as complex fittings and engine disks offers considerable cost savings due to reduced material and machining requirements

  7. HIP HOP for HIV Awareness: Using Hip Hop Culture to Promote Community-Level HIV Prevention

    Science.gov (United States)

    Hill, Mandy J.; Hallmark, Camden J.; McNeese, Marlene; Blue, Nike; Ross, Michael W.

    2014-01-01

    The goal of this paper was to determine the effectiveness of the HIP HOP for HIV Awareness intervention, an innovative model utilising an exchange of an HIV test for a hip hop concert ticket, in a metropolitan city among African American youth and young adults. A subset of intervention participants participated in standardised testing, sex…

  8. Modularity of Pressing Tools for Screw Press Producing Solid Biofuels

    Directory of Open Access Journals (Sweden)

    Miloš Matúš

    2012-01-01

    Full Text Available This paper focuses on the development of the newly-patented structure of a screw briquetting machine for compacting biomass into a solid biofuel. The design of the machine is based on the results of a comprehensive study of the complicated process of biomass compaction. The patented structure meets two main goals: the elimination of axial forces, leading to increased lifetime of the bearings, and the new modular design of a pressing chamber and tools with their geometry based on the application of a mathematical model.

  9. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  10. Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis.

    Science.gov (United States)

    Wellenberg, Ruud H H; Boomsma, Martijn F; van Osch, Jochen A C; Vlassenbroek, Alain; Milles, Julien; Edens, Mireille A; Streekstra, Geert J; Slump, Cornelis H; Maas, Mario

    To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.

  11. Progress in hot pressing

    International Nuclear Information System (INIS)

    Brodhag, C.; Thevenot, F.

    1988-01-01

    An experimental technique is described to study hot pressing of ceramics under conditions of controlled temperature and pressure during both the heating and final sintering stages. This method gives a better control of the final microstructure of the material. Transformation mechanisms can be studied during initial heating stage (impurity degasing, reaction, phase transformation, mechanical behavior of intergranular phase...) using computer control and graphical data representations. Some examples will be given for different systems studied in our laboratory: B (α, β, amorphous), B 12 O 2 (reaction of B + B 2 O 3 ), Si 3 N 4 ( + additives), TiN, Al 2 O 3 + AlON,ZrC

  12. First wall and shield components manufacturing by hot isostatic pressing

    International Nuclear Information System (INIS)

    Lind, Anders; Tegman, R.

    1994-01-01

    At a meeting in Garching in June 1994 Hot Isostatic Pressing (HIP) was presented as a possible route to manufacture ITER first wall and shield components. The main advantages of the HIP concept include excellent and uniform mechanical properties of the produced materials and joints, high reliability and robustness of the HIP process, double containment of coolant, good flexibility concerning general design as well as size and location for inner cooling tubes, low cost and short delivery times, and a good near net shape capability for components in size up to 15 tons. To assess the applicability of HIP for the manufacturing of ITER first wall and shield components, it was agreed * to choose possible production parameters based in the present know-how, * to produce a compound mock-up in one shot from available solid steel/powder copper/steel tubes to demonstrate the joinability of the materials, * to examine the produced mock-up/materials by multi array ultrasonic testing, limited mechanical testing, metallography, scanning electron microscopy and energy dispersive spectroscopy, and * to compile data on Type 316L steels produced by HIP. Preliminary results and the mock-up were presented at a meeting in Garching in mid July 1994. This study clearly shows the excellent joinability of a copper alloy (Cu-0.5%Zr) and stainless steels (Type 304, 316 L) by HIP at temperatures close to the melting temperature of copper, with only limited influence on the microstructures, which makes it possible to HIP the first wall and shield structure in one step. Excellent mechanical properties of the compound are obtained with the copper alloy and not the joint being the weakest part. 7 refs, 21 figs, 1 tab

  13. A murine model for developmental dysplasia of the hip: ablation of CX3CR1 affects acetabular morphology and gait

    Directory of Open Access Journals (Sweden)

    George Feldman

    2017-11-01

    Full Text Available Abstract Background Developmental dysplasia of the hip (DDH is a debilitating condition whose distinguishing signs include incomplete formation of the acetabulum leading to dislocation of the femur, accelerated wear of the articular cartilage and joint laxity resulting in osteoarthritis. It is a complex disorder having environmental and genetic causes. Existing techniques fail to detect milder forms of DDH in newborns leading to hip osteoarthritis in young adults. A sensitive, specific and cost effective test would allow identification of newborns that could be non-invasively corrected by the use of a Pavlik harness. Previously, we identified a 2.5 MB candidate region on human chromosome 3 by using linkage analysis of a 4 generation, 72 member family. Whole exome sequencing of the DNA of 4 severely affected members revealed a single nucleotide polymorphism variant, rs3732378 co-inherited by all 11 affected family members. This variant causes a threonine to methionine amino acid change in the coding sequence of the CX3CR1 chemokine receptor and is predicted to be harmful to the function of the protein To gain further insight into the function of this mutation we examined the effect of CX3CR1 ablation on the architecture of the mouse acetabulum and on the murine gait. Methods The hips of 5 and 8 weeks old wild type and CX3CR1 KO mice were analyzed using micro-CT to measure acetabular diameter and ten additional dimensional parameters. Eight week old mice were gait tested using an inclined treadmill with and without load and then underwent micro-CT analysis. Results (1 KO mice showed larger a 5–17% larger diameter left acetabula than WT mice at both ages. (2 At 8 weeks the normalized area of space (i.e. size discrepancy between the femur head and acetabulum is significantly larger [38% (p = 0.001–21% (p = 0.037] in the KO mice. (3 At 8 weeks gait analysis of these same mice shows several metrics that are consistent with impairment in

  14. From "They" Science to "Our" Science: Hip Hop Epistemology in STEAM Education

    Science.gov (United States)

    Dolberry, Maurice E.

    Hip hop has moved from being considered a type of music into being understood as a culture in which a prominent type of music originates. Hip hop culture has a philosophy and epistemological constructs as well. This study analyzed those constructs to determine how conceptions of science factor in hip hop worldviews. Pedagogical models in culturally responsive teaching and Science, Technology, Engineering, Arts, and Mathematics (STEAM) education were also examined to discern their philosophical connections with hip hop culture. These connections were used to create two theoretical models. The first one, Hip Hop Science, described how scientific thought functions in hip hop culture. The second model, Hip Hop STEAM Pedagogy, proposes how hip hop culture can inform STEAM teaching practices. The study began by using Critical Race Theory to create a theoretical framework proposing how the two theoretical models could be derived from the philosophical and pedagogical concepts. Content analysis and narrative inquiry were used to analyze data collected from scholarly texts, hip hop songs, and interviews with hip hop-responsive educators. The data from these sources were used initially to assess the adequacy of the proposed theoretical framework, and subsequently to improve its viability. Four overlapping themes emerged from the data analyses, including hip hop-resistance to formal education; how hip hop culture informs pedagogical practice in hip hop-responsive classrooms; conceptions of knowledge and reality that shape how hip hoppers conduct scientific inquiry; and hip hop-based philosophies of effective teaching for hip hoppers as a marginalized cultural group. The findings indicate that there are unique connections between hip hop epistemology, sciencemindedness, and pedagogical practices in STEAM education. The revised theoretical framework clarified the nature of these connections, and supported claims from prior research that hip hop culture provides viable sites of

  15. Development of HIP bonding procedure and mechanical properties of HIP bonded joints for reduced activation ferritic steel F-82H

    International Nuclear Information System (INIS)

    Oda, Masahiro; Kurasawa, Toshimasa; Kuroda, Toshimasa; Hatano, Toshihisa; Takatsu, Hideyuki

    1997-03-01

    Structural materials of blanket components in fusion DEMO reactors will receive a neutron wall load more than 3-5MW/m 2 as well as exposed by surface heat flux more than 0.5MW/m 2 . A reduced activation ferritic steel F-82H has been developed by JAERI in collaboration with NKK from viewpoints of resistance for high temperature and neutron loads and lower radioactivity. This study intends to obtain basic performance of F-82H to establish the fabrication procedure of the first wall and blanket box by using Hot Isostatic Pressing (HIP) bonding. Before HIP bonding tests, effects of heat treatment temperature and surface roughness on mechanical properties of joints were investigated in the heat treatment tests and diffusion bonding tests, respectively. From these results, the optimum HIP bonding conditions and the post heat treatment were selected. Using these conditions, the HIP bonding tests were carried out to evaluate HIP bondability and to obtain mechanical properties of the joints. Sufficient HIP bonding performance was obtained under the temperature of 1040degC, the compressive stress of 150MPa, the holding time of 2h, and the surface roughness ∼μ m. Mechanical properties of HIP bonded joints with these conditions were similar to those of as-received base metal. An oxide formation on the surface to be bonded would need to be avoided for sufficient bonding. The bonding ratio, Charpy impact value and fatigue performance of the joints strongly depended on the HIP conditions, especially temperature, while micro-structure, Vickers hardness and tensile properties had little dependence on the HIP temperature. The surface roughness strongly affected the bonding ratio and would be required to be in the level of a few μ m. In the HIP bonding test of the welded material, the once-melted surface could be jointed by the HIP bonding under the above-mentioned procedure. (J.P.N.)

  16. ISS Expedition 08 Press Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — Press kit for ISS mission Expedition 08 from 10/2003-04/2004. Press kits contain information about each mission overview, crew, mission timeline, benefits, and media...

  17. WordPress multisite administration

    CERN Document Server

    Longren, Tyler

    2013-01-01

    This is a simple, concise guide with a step-by-step approach, packed with screenshots and examples to set up and manage a network blog using WordPress.WordPress Multisite Administration is ideal for anyone wanting to familiarize themselves with WordPress Multisite. You'll need to know the basics about WordPress, and having at least a broad understanding of HTML, CSS, and PHP will help, but isn't required.

  18. TREATMENT OF HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (genu valgum, the ankles (ankle valgus, calcaneal valgus and the spine (scoliosis especially at the lumbar level. The most spectacular are at the hip level, that is why we made an analytical evaluation only for this joint. To show the importance of physiotherapy for children with hip dysplasia we started from the hypothesis: untimely treatment for children with hip dysplasia has improved results in functional recovery and in obtaining a better stability, without the necessity of orthopedics or surgical interventions. The research methods used in this study are: the observation method, the bibliographic study method, the experimental method, the graphics method and the statistical mathematical method to process the data and to represent the results graphically. In the end, the results obtained are significantly different from the initial evaluations and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient improves stability and biomechanical parameters for the hip.

  19. Hip arthroplasty for ochronosis

    International Nuclear Information System (INIS)

    Kerimoglu, S.; Onder, C.; Aynaci, O.; Malkoc, C. H.

    2005-01-01

    Alkaptonuria is a metabolic disorder in which homogentisic acid oxidase is absent. Therefore, homogentisic acid accumulates in cartilage and connective tissues. We can diagnose ochronotic arthropathy, a manifestation of long standing alkaptonuria, through careful radiological, physical, and laboratory examination. In this report, we describe 4 cases of ochronotic arthropathy to which we applied cementless total hip prosthesis due to severe hip involvement. (author)

  20. Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking

    Directory of Open Access Journals (Sweden)

    Alessandro Ruggiero

    2018-04-01

    Full Text Available The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.

  1. Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking.

    Science.gov (United States)

    Ruggiero, Alessandro; Merola, Massimiliano; Affatato, Saverio

    2018-04-09

    The hip joint replacement is one of the most successful orthopedic surgical procedures although it involves challenges to overcome. The patient group undergoing total hip arthroplasty now includes younger and more active patients who require a broad range of motion and a longer service lifetime for the replacement joint. It is well known that wear tests have a long duration and they are very expensive, thus studying the effects of geometry, loading, or alignment perturbations may be performed by Finite Element Analysis. The aim of the study was to evaluate total deformation and stress intensity on ultra-high molecular weight polyethylene liner coupled with hard material head during one step. Moving toward in-silico wear assessment of implants, in the presented simulations we used a musculoskeletal multibody model of a human body giving the loading and relative kinematic of the investigated tribo-system during the gait. The analysis compared two frictional conditions -dry and wet and two geometrical cases- with and without radial clearance. The loads and rotations followed the variability of the gait cycle as well as stress/strain acting in the UHWMPE cup. The obtained results allowed collection of the complete stress/strain description of the polyethylene cup during the gait and calculation of the maximum contact pressure on the lateral edge of the insert. The tensional state resulted in being more influenced by the geometrical conditions in terms of radial clearance than by the variation of the friction coefficients due to lubrication phenomena.

  2. Taking care of your new hip joint

    Science.gov (United States)

    Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... After you have hip replacement surgery, you will need to be careful how you move your hip, especially for the first few months ...

  3. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model.

    Science.gov (United States)

    Bragdon, Charles R; Malchau, Henrik; Yuan, Xunhua; Perinchief, Rebecca; Kärrholm, Johan; Börlin, Niclas; Estok, Daniel M; Harris, William H

    2002-07-01

    The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.

  4. Four Theories of the Press.

    Science.gov (United States)

    Siebert, Fred S.; And Others

    A systematic understanding of the press requires an understanding of the social and political structures within which the press operates. This book discusses four theories that have determined the kind of press the Western world has had: authoritarian, libertarian, socially responsible, and Soviet communist. Each chapter discusses press…

  5. Which Freedom of the Press?

    DEFF Research Database (Denmark)

    Rytter, Jens Elo

    2010-01-01

    The article surveys the historical and current meaning of "Freedom of the Press" in constitutional and human rights law. Two different conceptions exist, the narrow one defining freedom of the press as the freedom of every one to publish without prior restraint, the broader one defining it as a...... privileged freedom of the organised press to gather and report on information of public interest. These two conceptions have very different answers to the question of whether the press should enjoy some privilege to be exempt from ordinary legislation when such legislation restricts the access of the press to inform...

  6. WordPress for dummies

    CERN Document Server

    Sabin-Wilson, Lisa

    2014-01-01

    The bestselling WordPress guide, fully updated to cover the 2013 enhancements WordPress has millions of users, and this popular guide has sold more than 105,000 copies in its previous editions. With the newest releases of WordPress, author and WordPress expert Lisa Sabin-Wilson has completely updated the book to help you use and understand all the latest features. You'll learn about both the hosted WordPress.com version and the more flexible WordPress.org, which requires third-party hosting. Whether you're switching to WordPress from another blogging platform or just beginning to blog, you'll

  7. Effect of Hot-isostatic Pressing on Microstructure and Mechanical Properties of Second Generation Single Crystal Superalloy DD6

    Directory of Open Access Journals (Sweden)

    GUO Hui-ming

    2016-10-01

    Full Text Available Effects of the hot-isostatic pressing (HIP temperature (1280,1300,1320℃ on microstructures and mechanical properties of a second generation single crystal superalloy DD6 were investigated. The results show that the HIP treatment significantly decrease the cast porosity number of DD6 compared with standard treated specimens. Especially, the cast porosity volume fraction is deceased from 0.31% to 0.04% after the HIP treatment of 1300℃/100MPa, 4h. The cast eutectic volume fractions are remarkably reduced with increasing HIP temperature. The HIP treatments nearly unchanged the creep lives, While they greatly promote the low cycle fatigue lives. The elimination of cast microspores using the HIP treatment of 1300℃/100MPa, 4h result in the inhibition of crack initiation during fatigue and improve the low cycle fatigue lives one order of magnitude larger than that after standard heat treatment.

  8. Effects of Temperature and Pressure of Hot Isostatic Pressing on the Grain Structure of Powder Metallurgy Superalloy.

    Science.gov (United States)

    Tan, Liming; He, Guoai; Liu, Feng; Li, Yunping; Jiang, Liang

    2018-02-24

    The microstructure with homogeneously distributed grains and less prior particle boundary (PPB) precipitates is always desired for powder metallurgy superalloys after hot isostatic pressing (HIPping). In this work, we studied the effects of HIPping parameters, temperature and pressure on the grain structure in PM superalloy FGH96, by means of scanning electron microscope (SEM), electron backscatter diffraction (EBSD), transmission electron microscope (TEM) and Time-of-flight secondary ion spectrometry (ToF-SIMS). It was found that temperature and pressure played different roles in controlling PPB precipitation and grain structure during HIPping, the tendency of grain coarsening under high temperature could be inhibited by increasing HIPping pressure which facilitates the recrystallization. In general, relatively high temperature and pressure of HIPping were preferred to obtain an as-HIPped superalloy FGH96 with diminished PPB precipitation and homogeneously refined grains.

  9. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  10. WordPress For Dummies

    CERN Document Server

    Sabin-Wilson, Lisa

    2011-01-01

    The bestselling guide to WordPress, fully updated to help you get your blog going! Millions of bloggers rely on WordPress, the popular, free blogging platform. This guide covers all the features and improvements in the most up-to-date version of WordPress. Whether you are switching to WordPress from another blogging platform or just starting your first blog, you'll find the advice in this friendly guide gets you up to speed on both the free-hosted WordPress.com version and WordPress.org, which requires the purchase of web hosting services, and figure out which version is best for you. You'll b

  11. Methodological comparison of marginal structural model, time-varying Cox regression, and propensity score methods: the example of antidepressant use and the risk of hip fracture.

    Science.gov (United States)

    Ali, M Sanni; Groenwold, Rolf H H; Belitser, Svetlana V; Souverein, Patrick C; Martín, Elisa; Gatto, Nicolle M; Huerta, Consuelo; Gardarsdottir, Helga; Roes, Kit C B; Hoes, Arno W; de Boer, Antonius; Klungel, Olaf H

    2016-03-01

    Observational studies including time-varying treatments are prone to confounding. We compared time-varying Cox regression analysis, propensity score (PS) methods, and marginal structural models (MSMs) in a study of antidepressant [selective serotonin reuptake inhibitors (SSRIs)] use and the risk of hip fracture. A cohort of patients with a first prescription for antidepressants (SSRI or tricyclic antidepressants) was extracted from the Dutch Mondriaan and Spanish Base de datos para la Investigación Farmacoepidemiológica en Atención Primaria (BIFAP) general practice databases for the period 2001-2009. The net (total) effect of SSRI versus no SSRI on the risk of hip fracture was estimated using time-varying Cox regression, stratification and covariate adjustment using the PS, and MSM. In MSM, censoring was accounted for by inverse probability of censoring weights. The crude hazard ratio (HR) of SSRI use versus no SSRI use on hip fracture was 1.75 (95%CI: 1.12, 2.72) in Mondriaan and 2.09 (1.89, 2.32) in BIFAP. After confounding adjustment using time-varying Cox regression, stratification, and covariate adjustment using the PS, HRs increased in Mondriaan [2.59 (1.63, 4.12), 2.64 (1.63, 4.25), and 2.82 (1.63, 4.25), respectively] and decreased in BIFAP [1.56 (1.40, 1.73), 1.54 (1.39, 1.71), and 1.61 (1.45, 1.78), respectively]. MSMs with stabilized weights yielded HR 2.15 (1.30, 3.55) in Mondriaan and 1.63 (1.28, 2.07) in BIFAP when accounting for censoring and 2.13 (1.32, 3.45) in Mondriaan and 1.66 (1.30, 2.12) in BIFAP without accounting for censoring. In this empirical study, differences between the different methods to control for time-dependent confounding were small. The observed differences in treatment effect estimates between the databases are likely attributable to different confounding information in the datasets, illustrating that adequate information on (time-varying) confounding is crucial to prevent bias. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Transient osteoporosis of hip

    Directory of Open Access Journals (Sweden)

    Mahesh M Choudhary

    2015-01-01

    Full Text Available We report a case of transient osteoporosis of the hip (TOH in a 50-year-old man including the clinical presentation, diagnostic studies, management, and clinical progress. TOH is a rare self-limiting condition that typically affects middle-aged men or, less frequently, women in the third trimester of pregnancy. Affected individuals present clinically with acute hip pain, limping gait, and limited ranges of hip motion. TOH may begin spontaneously or after a minor trauma. Radiographs are typically unremarkable but magnetic resonance (MR imaging studies yield findings consistent with bone marrow edema. TOH is referred to as regional migratory osteoporosis (RMO if it travels to other joints or the contralateral hip. TOH often resembles osteonecrosis but the two conditions must be differentiated due to different prognoses and management approaches. The term TOH is often used interchangeably and synonymously with transient bone marrow edema (TBME.

  13. Danish Hip Arthroscopy Registry

    DEFF Research Database (Denmark)

    Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten; Maagaard, Niels

    2016-01-01

    Danish Hip Arthroscopy Registry (DHAR) was initiated in 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the epidemiologic and perioperative data of the first 2000 procedures in a Danish hip arthroscopy population and to describe the development of DHAR...... was 0.65 and HAGOS sub-scores were 51 (pain), 49 (symptoms), 53 (ADL), 35 (sport), 20 (physical activity) and 29, respectively. We conclude that patients undergoing hip arthroscopy report considerable pain, loss of function, reduced level of activity and reduced quality-of-life prior to surgery....... The problems with development and maintaining a large clinical registry are described and further studies are needed to validate data completeness. We consider the development of a national clinical registry for hip arthroscopy as a successful way of developing and maintaining a valuable clinical...

  14. Osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Takatori, Yoshio; Sasaki, Yasuhito

    1993-01-01

    Magnetic resonance imaging (MRI) is the modality of choice for evaluation of joint disease. Forty-one hips in 33 patients with osteoarthritis of the hip joint were examined by MRI and the features were analyzed. MR examinations were performed on a 1.5 T superconducting unit using the spin echo (SE) technique with short TR (600 ms)/short TE (23, 28, 35 ms) and short TR (600 ms)/long TE (70, 75 ms) sequences. MRI revealed deformity of the femoral head in all hips. Some outgrowths, which were isointense with normal bone marrow, were shown on the periphery of the femoral head in 22 hips (54%). These outgrowths represented marginal osteophytes. Short TE images showed hypointense areas, which varied in size, in the superior or supero-anterior aspect of the femoral head in all hips, and in the opposite position of the acetabulum in 38 hips (93%). These lesions showed a heterogenous signal with predominant low signal on long TE images. These images may indicate the presence of several components including subchondral cysts, bony sclerosis and fibrous tissue. In the joint space, areas of low signal intensity were shown on short TE images, which were high to intermediate signal intensity on long TE images in 16 hips (39%). These areas were presumably consistent with synovial proliferation, cartilageous hypertrophy or joint effusion. Both MR images revealed a mass locating just anterior to the femoral head in 2 hips (5%). The mass showed a low signal on short TE images and a high signal on long TE images, representing the distended iliopsoas bursa. (author)

  15. WordPress Top Plugins

    CERN Document Server

    Corbin, Brandon

    2010-01-01

    Time flies when you're having fun. This is the right way to describe this WordPress Top Plugins book by Brandon Corbin. With real world examples and by showing you the perks of having these plugins installed on your websites, the author is all set to captivate your interest from start to end. Regardless of whether this is your first time working with WordPress, or you're a seasoned WordPress coding ninja, WordPress Top Plugins will walk you through finding and installing the best plugins for generating and sharing content, building communities and reader base, and generating real advertising r

  16. Athletic Hip Injuries.

    Science.gov (United States)

    Lynch, T Sean; Bedi, Asheesh; Larson, Christopher M

    2017-04-01

    Historically, athletic hip injuries have garnered little attention; however, these injuries account for approximately 6% of all sports injuries and their prevalence is increasing. At times, the diagnosis and management of hip injuries can be challenging and elusive for the team physician. Hip injuries are seen in high-level athletes who participate in cutting and pivoting sports that require rapid acceleration and deceleration. Described previously as the "sports hip triad," these injuries consist of adductor strains, osteitis pubis, athletic pubalgia, or core muscle injury, often with underlying range-of-motion limitations secondary to femoroacetabular impingement. These disorders can happen in isolation but frequently occur in combination. To add to the diagnostic challenge, numerous intra-articular disorders and extra-articular soft-tissue restraints about the hip can serve as pain generators, in addition to referred pain from the lumbar spine, bowel, bladder, and reproductive organs. Athletic hip conditions can be debilitating and often require a timely diagnosis to provide appropriate intervention.

  17. Effect of Tooling Material on the Internal Surface Quality of Ti6Al4V Parts Fabricated by Hot Isostatic Pressing

    Science.gov (United States)

    Cai, Chao; Song, Bo; Wei, Qingsong; Yan, Wu; Xue, Pengju; Shi, Yusheng

    2017-01-01

    For the net-shape hot isostatic pressing (HIP) process, control of the internal surface roughness of as-HIPped parts remains a challenge for practical engineering. To reveal the evolution mechanism of the internal surface of the parts during the HIP process, the effect of different tooling materials (H13, T8, Cr12 steel, and graphite) as internal cores on the interfacial diffusion and surface roughness was systematically studied.

  18. Impact properties of reduced activation ferritic/martensitic steel, F82H jointed by hot isostatic pressing

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H.; Tanigawa, H. [Japan Atomic Energy Agency, Tokai-mura, Naga-gun, Ibaraki-ken (Japan); Hirose, T. [Blanket Engineering Group, Japan Atomic Energy Agency, Naka, Ibaraki (Japan); Enoeda, M. [Naka Fusion Research Establishment, J.A.E.R.I., Japan Atomic Energy Research Institute, Ibaraki-ken (Japan); Kohyama, A. [Kyoto Univ., lnstitute of Advanced Energy (Japan)

    2007-07-01

    Full text of publication follows: Reduced-activation ferritic/martensitic steels are the leading candidate structural material for the blanket system of fusion reactors. The important issue at the current stage is the finalization of a detailed manufacturing specification for ITER test blanket module. Hot isostatic pressing (HIP) process is one of the most important methods to fabricate the first wall with cooling channels. The objective of this paper is to optimize HIP condition to obtain the excellent joints mechanical properties. The materials used were F82H steels. The joint was produced by solid state HIP method. Before HIP treatments, specimens were heated in vacuum condition to out-gas. This treatment was conducted to decrease oxidation on the surfaces. HIP treatments were carried out for 2 h at 1100 deg. C - 140 MPa. The specimens were normalized at 960 deg. C for 0.5 h and tempered at 750 deg. C for 1.5 h. The bonding interface was characterized by scanning electron microscopy. Charpy impact tests and tensile tests were conducted to evaluate the mechanical properties of the HIP joint. Impact tests revealed that there were no significant differences in the ductile-brittle transition temperatures of HIP jointed specimens and base metal specimens, but the upper-shelf energy (USE) of the HIP joint specimens at room temperature was only about 10% of that of the base metal specimens. SEM observations of the fracture surface of HIP joint specimens revealed that a large number of oxides were formed on the HIP joint. This result indicates that oxides formed on the HIP joint are the dominant factor of the impact properties. Based on these results, the pre-HIP treatment conditions had been optimized to reduce the number of oxides, and USE of HIP joint specimens increased to about 50% of that of the base metal. The detailed analyses on the HIP joint microstructure will be reported. (authors)

  19. Marker-based or model-based RSA for evaluation of hip resurfacing arthroplasty? A clinical validation and 5-year follow-up.

    Science.gov (United States)

    Lorenzen, Nina Dyrberg; Stilling, Maiken; Jakobsen, Stig Storgaard; Gustafson, Klas; Søballe, Kjeld; Baad-Hansen, Thomas

    2013-11-01

    The stability of implants is vital to ensure a long-term survival. RSA determines micro-motions of implants as a predictor of early implant failure. RSA can be performed as a marker- or model-based analysis. So far, CAD and RE model-based RSA have not been validated for use in hip resurfacing arthroplasty (HRA). A phantom study determined the precision of marker-based and CAD and RE model-based RSA on a HRA implant. In a clinical study, 19 patients were followed with stereoradiographs until 5 years after surgery. Analysis of double-examination migration results determined the clinical precision of marker-based and CAD model-based RSA, and at the 5-year follow-up, results of the total translation (TT) and the total rotation (TR) for marker- and CAD model-based RSA were compared. The phantom study showed that comparison of the precision (SDdiff) in marker-based RSA analysis was more precise than model-based RSA analysis in TT (p CAD RSA analysis (p = 0.002), but showed no difference between the marker- and CAD model-based RSA analysis regarding the TR (p = 0.91). Comparing the mean signed values regarding the TT and the TR at the 5-year follow-up in 13 patients, the TT was lower (p = 0.03) and the TR higher (p = 0.04) in the marker-based RSA compared to CAD model-based RSA. The precision of marker-based RSA was significantly better than model-based RSA. However, problems with occluded markers lead to exclusion of many patients which was not a problem with model-based RSA. HRA were stable at the 5-year follow-up. The detection limit was 0.2 mm TT and 1° TR for marker-based and 0.5 mm TT and 1° TR for CAD model-based RSA for HRA.

  20. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Directory of Open Access Journals (Sweden)

    Haviv Barak

    2010-07-01

    Full Text Available Abstract Objective To assess the incidence of total hip arthroplasty (THA in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years. The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16% of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.

  1. Results of hip arthroplasty using Paavilainen technique in patients with congenitally dislocated hip

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2014-01-01

    Full Text Available The purpose of the study was to analyze the medium- and long-term results of hip arthroplasty using Paavilainen technique in patients with the congenitally dislocated hip. Methods: From 2001 to 2012 180 operations were carried out were using the Paavilainen technique in 140 patients with high dislocation of the hip (Crowe IV. All patients were clinically evaluated using the Harris Hip Score (HHS, VAS and radiography. Statistical analysis was performed using the Pearson correlation coefficients, multiple regression analysis and classification trees analysis. Results: The average Harris score improved from preoperative 41.6 (40,3-43,5 to 79.3 (77,9-82,7 at final follow-up, and the difference was significant. Early complications were 9% (the most frequent were fractures of the proximal femur, later - 16.7% (pseudoarthrosis of the greater trochanter, 13.9%; disclocations-1,1%, aseptic loosening of the components - 1.7%, reoperation performed in 8.3% of cases. Such factors as age and limb length has statistically significant effect on functional outcomes. Established predictive model allows to get the best possible functional outcome in such patients with severe dysplasia. Conclusions: Total Hip arthroplasty using the Paavilainen technique is an effective method of surgical treatment in patients with the congenitally dislocated hip, but it is technically difficult operation with a high incidence of complications in comparison with standard primary total hip replacement.

  2. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Science.gov (United States)

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  3. Hot isostatic pressing of glass-zeolite composites

    International Nuclear Information System (INIS)

    Hash, M.C.; Pereira, C.; Lewis, M.A.

    1996-01-01

    Glass-zeolite waste forms are being developed for immobilizing the chloride waste salt generated from the electrometallurgical treatment of spent fuel. Glass-zeolite composites with high densities were made using hot isostatic pressing (HIP) techniques. Processing parameters were investigated to yield desirable structural ceramic properties such as mechanical, chemical, and thermal stability. Limits for these parameters were determined by differential thermal and thermogravimetric analysis. The resulting ceramic properties such as bulk density, open or apparent porosity, and leach resistance were determined. In addition, phase equilibria and particle-size distribution were observed by optical light and electron microscopy. Pre-HIP processing techniques were also studied to ensure intimate mixing of the glass and zeolite powders. Particle size distributions resulting from dry blending procedure are appropriate for needed flow and packing characteristics

  4. Ductility in hot isostatically pressed 250-grade maraging steel

    International Nuclear Information System (INIS)

    German, R.M.; Smugeresky, J.E.

    1978-01-01

    Prealloyed 250-grade maraging steel powder produced by the rotating electrode process was fully consolidated by hot isostatic pressing (HIP) at 1100 and 1200 0 C. The strength following aging (3 h at 480 0 C) equalled that of wrought material; however, ductility was negligible. This lack of ductility in the powder metallurgy product was traced to titanium segregation which occurred at the powder surface during power production. The formation of a titanium intermetallic at the prior particle boundaries during aging caused failure at low plastic strains. Altered aging treatments successfully broke up the embrittling film and resulted in a significant ductility recovery for the HIP material. Analysis of the fracture process indicates that further ductility gains are possible by reducing the titanium content, refining the particle size, and optimizing the thermal cycles

  5. A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants.

    Science.gov (United States)

    Bougherara, Habiba; Zdero, Rad; Dubov, Anton; Shah, Suraj; Khurshid, Shaheen; Schemitsch, Emil H

    2011-01-01

    Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R(2)=0.69, slope=0.82), Exeter (Pearson R(2)=0.78, slope=0.59), and Omnifit (Pearson R(2)=0.66, slope=0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Indre spenninger og ytre press

    DEFF Research Database (Denmark)

    Ibsen, Bjarne

    2011-01-01

    Anmeldelse af bogen 'Norsk idrett. Indre spenninger og ytre press' redigeret af Dag Vidar Hanstad, Gunnar Breivik, Mari Kristin Sisjord og Hans B. Skaset og udgivet af forlaet akilles.......Anmeldelse af bogen 'Norsk idrett. Indre spenninger og ytre press' redigeret af Dag Vidar Hanstad, Gunnar Breivik, Mari Kristin Sisjord og Hans B. Skaset og udgivet af forlaet akilles....

  7. BuddyPress theme development

    CERN Document Server

    Lister, Tammie

    2013-01-01

    This book is a hands-on tutorial guide to using BuddyPress.This book is great for designers and developers who are looking to learn how to develop BuddyPress themes. It's assumed that the reader has some understanding of Wordpress and is familiar with CSS and HTML.

  8. Head First WordPress

    CERN Document Server

    Siarto, Jeff

    2010-01-01

    Whether you're promoting your business or writing about your travel adventures, Head First WordPress will teach you not only how to make your blog look unique and attention-grabbing, but also how to dig into the more complex features of WordPress 3.0 to make your website work well, too. You'll learn how to move beyond the standard WordPress look and feel by customizing your blog with your own URL, templates, plugin functionality, and more. As you learn, you'll be working with real WordPress files: The book's website provides pre-fab WordPress themes to download and work with as you follow al

  9. The Hyperflexible Hip

    Science.gov (United States)

    Weber, Alexander E.; Bedi, Asheesh; Tibor, Lisa M.; Zaltz, Ira; Larson, Christopher M.

    2015-01-01

    Context: Dance, gymnastics, figure skating, and competitive cheerleading require a high degree of hip range of motion. Athletes who participate in these sports use their hips in a mechanically complex manner. Evidence Acquisition: A search of the entire PubMed database (through December 2013) and additional searches of the reference lists of pertinent articles. Study Design: Systematic review. Level of Evidence: Level 3. Results: Whether innate or acquired, dancers and gymnasts have some hypermobility that allows their hips to be placed in potentially impinging or unstable positions required for their given activity. Such extremes of motion can result in both intra-articular and extra-articular impingement as well as compensatory osseous and muscular pathology. In addition, dancers and gymnasts are susceptible to impingement-induced instability. Dancers with innate generalized hyperlaxity are at increased risk of injury because of their activities and may require longer recovery times to return to play. Both nonoperative and operative treatments (arthroscopic and open) have an important role in returning flexibility athletes to their preoperative levels of sport and dance. Conclusion: Because of the extreme hip motion required and the compensatory soft tissue laxity in dancers and gymnasts, these athletes may develop instability, impingement, or combinations of both. This frequently occurs in the setting of subtle pathoanatomy or in patients with normal bony anatomy. With appropriate surgical indications and the correct operative technique, the treating surgeon can anticipate high levels of return to play for the gymnast and dancer with hip pain. PMID:26137181

  10. Complications in Hip Arthroscopy

    Science.gov (United States)

    Nakano, Naoki; Khanduja, Vikas

    2016-01-01

    Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747

  11. Hip Replacement: MedlinePlus Health Topic

    Science.gov (United States)

    ... invasive hip replacement (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Hip Replacement updates ... replacement - precautions Minimally invasive hip replacement Related Health Topics Hip Injuries and Disorders National Institutes of Health ...

  12. Smashing WordPress Themes Making WordPress Beautiful

    CERN Document Server

    Hedengren, Thord Daniel

    2011-01-01

    The ultimate guide to WordPress Themes - one of the hottest topics on the web today WordPress is so much more than a blogging platform, and Smashing WordPress Themes teaches readers how to make it look any way they like - from a corporate site, to a photography gallery and moreWordPress is one of the hottest tools on the web today and is used by sites including The New York Times, Rolling Stone, flickr, CNN, NASA and of course Smashing MagazineBeautiful full colour throughout - web designers expect nothing lessSmashing Magazine will fully support this book by by promoting it through their webs

  13. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    Bierma-Zeinstra, S. M.; Bohnen, A. M.; Verhaar, J. A.; Prins, A.; Ginai-Karamat, A. Z.; Laméris, J. S.

    2000-01-01

    To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. Patients (n = 224) aged 50 years or older with hip pain, referred by the general practitioner for radiological investigation, underwent a

  14. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    S.M. Bierma-Zeinstra (Sita); A.M. Bohnen (Arthur); J.A.N. Verhaar (Jan); A. Prins (Ad); J.S. Lameris; A.Z. Ginai (Abida)

    2000-01-01

    textabstractOBJECTIVE: To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. METHODS: Patients (n = 224) aged 50 years or older with hip pain, referred by the general

  15. Strength-ductility relationships in intermediate purity hot-pressed beryllium

    International Nuclear Information System (INIS)

    Stonehouse, A.J.; Bielawski, C.A.; Paine, R.M.

    1977-01-01

    The strength of vacuum hot-pressed, intermediate purity beryllium may be substantially increased without sacrifice of the strain capacity of the present grade (S-65) through decrease in the average grain size. Tensile strength of 517 MPa, 0.2% offset yield strength of 414 MPa with minimum 3% tensile elongation in all test directions could be commercially achieved. The tangent modulus of such material is quite attractive and suffers only about 10% degradation from room temperature to 260 0 C. The tangent modulus is dramatically enhanced by the presence of a yield point. The ductility of the materials studied did not appear to be affected by the BeO content across the range of 0.5 to 2.0% using nominal -44 to -15 μm powder particle sizes. All fine-grained pressings exhibited yield points in the as-pressed condition. Either full-density or sub-density hot-pressed billets given a hot isostatic pressing treatment without the use of cans showed only slight yield points after the HIP treatment with essentially the same strength and ductility factors as in the pressed condition. A plot of grain size vs yield strength in the as-pressed condition projects to an intercept with the fracture strength line at about 3 μm grain size. A similar plot after the HIP treatment shows a yield strength line parallel to the fracture strength line with no projected intercept predicting a completely brittle material. (author)

  16. Hip joint pathology

    DEFF Research Database (Denmark)

    Tijssen, M; van Cingel, R E H; de Visser, E

    2017-01-01

    The purpose of this retrospective cohort study was to (a) describe the clinical presentation of femoroacetabular impingement (FAI) and hip labral pathology; (b) describe the accuracy of patient history and physical tests for FAI and labral pathology as confirmed by hip arthroscopy. Patients (18......-65 years) were included if they were referred to a physical therapist to gather pre-operative data and were then diagnosed during arthroscopy. Results of pre-operative patient history and physical tests were collected and compared to arthroscopy. Data of 77 active patients (mean age: 37 years) were...

  17. An Assessment of the Ductile Fracture Behaviour of Hot Isostatically Pressed and Forged 304L Stainless Steel

    OpenAIRE

    Cooper, Adam; Smith, R. J.; Sherry, Andrew

    2017-01-01

    Type 300 austenitic stainless steel manufactured by hot isostatic pressing (HIP) has recently been shown to exhibit subtly different fracture behavior from that of equivalent graded forged steel, whereby the oxygen remaining in the component after HIP manifests itself in the austenite matrix as nonmetallic oxide inclusions. These inclusions facilitate fracture by acting as nucleation sites for the initiation, growth, and coalescence of microvoids in the plastically deforming austenite matrix....

  18. Hip arthroplasty today and tomorrow.

    Science.gov (United States)

    Amstutz, H C

    1987-12-01

    Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.

  19. Science coverage and the press

    International Nuclear Information System (INIS)

    Hawkes, N.

    1992-01-01

    The writer, a journalist, summarizes the discussion of the Chilton Seminar, February 1992, and discusses the problems of bridging the incomprehension gap between scientists and lay readers of the press. (Author)

  20. Hot-pressing steatite bodies

    International Nuclear Information System (INIS)

    Aparicio Arroyo, E.

    1967-01-01

    Requirements for some special nuclear engineering ceramic shapes are: big size, impervious, dimensional accuracy and good mechanical and dielectric properties. Limitations of te conventional methods and advantages of te hot pressing techniques for the manufacturing of these shapes are discussed. Hot pressing characteristics of a certain steatite powder are studied. Occurrence of an optimum densification temperature just above the tale decomposition range is found. Experimental data show that the height/diameter ratio of the specimen has no effect on the sintering conditions. Increasing darkness from the graphite mould is detected above the optimum temperature. The hot-pressed steatite is compared with a fired dry-pressed sample of the same composition. (Author) 13 refs

  1. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  2. Normative values of eccentric hip abduction strength in novice runners

    DEFF Research Database (Denmark)

    Jørgensen, Daniel Ramskov; Pedersen, Mette Broen; Kastrup, Kristrian

    2014-01-01

    .354) Nm/kg. CONCLUSION: Normative values for maximal eccentric hip abduction strength in novice runners can be calculated by taking into account the differences in strength across genders and the decline in strength that occurs with increasing age. Age and gender were associated with maximal eccentric hip...... associated with maximal eccentric hip abduction strength from a univariate analysis were included in a multivariate linear regression model. Based on the results from the regression model, a regression equation for normative hip abduction strength is presented. RESULTS: A SIGNIFICANT DIFFERENCE IN MAXIMAL...... was found, p gender. Based on this, the equation to calculate normative values for relative eccentric hip abduction strength became: (1.600 + (age * -0.005) + (gender (1 = male / 0 = female) * 0.215) ± 1 or 2 * 0...

  3. Um sistema de ventrículo pulmonar produzindo pressão pulsátil em único ventrículo: modelo experimental A pulmonary ventricle system producing pulsatile pressure in single ventricle: experimental model

    Directory of Open Access Journals (Sweden)

    Bilgein Emrecan

    2006-09-01

    Full Text Available OBJETIVO: Pacientes com ventrículo único funcional têm prognóstico ruim, que resulta em insuficiência cardíaca, mesmo após tratamento cirúrgico. As operações derivação cavo-pulmonar (exceto pelas conexões do átrio direito ao ventrículo direito não apresentam sistema ventricular pulmonar com pressão pulsátil, além do fluxo reduzido ao ventrículo único. Para resolver o problema, tentamos criar um ventrículo pulmonar que produza pressão pulsátil experimentalmente. MÉTODO: Tentamos criar um sistema ventricular direito que produzisse pressão pulsátil. O modelo experimental foi realizado em seis ovelhas. As pressões do ventrículo pulmonar criado, da artéria pulmonar e do ventrículo esquerdo foram medidas após a saída da circulação extracorpórea. RESULTADOS: A média das pressões arteriais pulmonares sistólica e diastólica foi 15,6 ± 2,0 mmHg e 4,5 ± 1,5 mmHg. A média da pressão sistólica ventricular esquerda foi 76,6 ± 4,4 mmHg. CONCLUSÃO: Um ventrículo que produza pressão pulsátil é necessário para a regulação do fluxo da artéria pulmonar, com pressão venosa central e pressão pulmonar não pulsátil nas anomalias como ventrículos únicos funcionais.OBJECTIVE: Patients with functional single ventricle show bad survey, most of which result in cardiac failure even in the case that they are operated. The right heart bypass operations except for right atrium and right ventricle connections lack pulsatile pulmonary ventricle system besides the volume lack coming to the common ventricle. To solve the problem, we tried to create a pulmonary ventricle which produces pulsatile pressure experimentally. METHODS: We tried to form a right ventricle system which produces pulsatile pressure. The experimental model was carried on six sheep. The pressures of the created pulmonary ventricle, pulmonary artery and the left ventricle were measured after leaving the cardiopulmonary bypass. RESULTS: The mean of the

  4. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Directory of Open Access Journals (Sweden)

    Jörg Tomeczkowski

    Full Text Available OBJECTIVES: Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategyduring elective hip and knee replacement surgery. METHODS: Individual patients (N = 50,000 were simulated based on data from controlled trials, the German DRG institute (InEK and various publications and entered into a stochastic model (Monte-Carlo of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit, pneumonia treatment (€5,000, and length of stay (€300/day. Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. RESULTS: At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. CONCLUSIONS: EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  5. Potential cost saving of Epoetin alfa in elective hip or knee surgery due to reduction in blood transfusions and their side effects: a discrete-event simulation model.

    Science.gov (United States)

    Tomeczkowski, Jörg; Stern, Sean; Müller, Alfred; von Heymann, Christian

    2013-01-01

    Transfusion of allogeneic blood is still common in orthopedic surgery. This analysis evaluates from the perspective of a German hospital the potential cost savings of Epoetin alfa (EPO) compared to predonated autologous blood transfusions or to a nobloodconservationstrategy (allogeneic blood transfusion strategy)during elective hip and knee replacement surgery. Individual patients (N = 50,000) were simulated based on data from controlled trials, the German DRG institute (InEK) and various publications and entered into a stochastic model (Monte-Carlo) of three treatment arms: EPO, preoperative autologous donation and nobloodconservationstrategy. All three strategies lead to a different risk for an allogeneic blood transfusion. The model focused on the costs and events of the three different procedures. The costs were obtained from clinical trial databases, the German DRG system, patient records and medical publications: transfusion (allogeneic red blood cells: €320/unit and autologous red blood cells: €250/unit), pneumonia treatment (€5,000), and length of stay (€300/day). Probabilistic sensitivity analyses were performed to determine which factors had an influence on the model's clinical and cost outcomes. At acquisition costs of €200/40,000 IU EPO is cost saving compared to autologous blood donation, and cost-effective compared to a nobloodconservationstrategy. The results were most sensitive to the cost of EPO, blood units and hospital days. EPO might become an attractive blood conservation strategy for anemic patients at reasonable costs due to the reduction in allogeneic blood transfusions, in the modeled incidence of transfusion-associated pneumonia andthe prolongedlength of stay.

  6. Danish Hip Arthroscopy Registry

    DEFF Research Database (Denmark)

    Mygind-Klavsen, Bjarne; Lund, Bent; Nielsen, Torsten Grønbech

    2018-01-01

    PURPOSE: Predictors of outcome after femoroacetabular impingement (FAI) surgery are not well-documented. This study presents data from the Danish Hip Arthroscopy Registry (DHAR) for such analyses. The purpose of this study was to identify predictors of poor outcome after FAI surgery in a Danish FAI...

  7. The sagittal stem alignment and the stem version clearly influence the impingement-free range of motion in total hip arthroplasty: a computer model-based analysis.

    Science.gov (United States)

    Müller, Michael; Duda, Georg; Perka, Carsten; Tohtz, Stephan

    2016-03-01

    The component alignment in total hip arthroplasty influences the impingement-free range of motion (ROM). While substantiated data is available for the cup positioning, little is known about the stem alignment. Especially stem rotation and the sagittal alignment influence the position of the cone in relation to the edge of the socket and thus the impingement-free functioning. Hence, the question arises as to what influence do these parameters have on the impingement-free ROM? With the help of a computer model the influence of the sagittal stem alignment and rotation on the impingement-free ROM were investigated. The computer model was based on the CT dataset of a patient with a non-cemented THA. In the model the stem version was set at 10°/0°/-10° and the sagittal alignment at 5°/0°/-5°, which resulted in nine alternative stem positions. For each position, the maximum impingement-free ROM was investigated. Both stem version and sagittal stem alignment have a relevant influence on the impingement-free ROM. In particular, flexion and extension as well as internal and external rotation capability present evident differences. In the position intervals of 10° sagittal stem alignment and 20° stem version a difference was found of about 80° in the flexion and 50° in the extension capability. Likewise, differences were evidenced of up to 72° in the internal and up to 36° in the external rotation. The sagittal stem alignment and the stem torsion have a relevant influence on the impingement-free ROM. To clarify the causes of an impingement or accompanying problems, both parameters should be examined and, if possible, a combined assessment of these factors should be made.

  8. Treatment of zircaloy cladding hulls by isostatic pressing

    International Nuclear Information System (INIS)

    Tegman, R.; Burstroem, M.

    1984-12-01

    A method for the treatment of Zircaloy fuel hulls is proposed. It involves hot isostatic pressing (HIP) for making large, completely densified metallic bodies of the waste. The hulls are packed into a bellows-shaped container of steel. On packing the fuel hulls give a filling factor of only 14%, which is too low for non-deformable compaction in a normal container, but by using a belloped container, a non-deformable compaction can be obtained without any pretreatment of the hulls. Fully dense and mechanically strong blocks of Zircaloy can be fabricated by holding them at temperatures of around 1000 degrees C for three hours. It is also feasible to incorporate the other metallic parts of the fuel bundle, such as top and bottom tie plates and spacers, in the pressing. The HIP-densified hulls provide an effective means of self-containment of radioactive waste due to the excellent corrosion resistance of Zircaloy. A waste loading factor of close to 100% can be realized. Futher, a volume reduction factor of 7 and a surface reduction factor of aout 250 for a 1-ton canister can be achieved. Equilibrium calculations have shown that tritium present in the hulls can quantitatively be contained in the HIPed block. A study has been made of a possible process for industrilscale use. (Author)

  9. Press-pack components electro-thermo-fluidic modeling: application to the Integrated Gate Commutated Thyristor 4,5 kV-4 kA; Modelisation des couplages electro-thermo-fluidiques des composants en boitier press-pack: application a l'integrated gate commutated thyristor 4,5kV-4kA

    Energy Technology Data Exchange (ETDEWEB)

    Feral, H.

    2005-09-15

    Temperature is an important parameter when you use semi-conductors. In the multi MW power converters the semiconductor losses are upper than kW. The thermal analyzes of the semiconductor package and cooling system must be performed to understand the thermal limitations. The maximal temperature can not be upper than 150 deg. C for silicon components. The temperature variations have an impact on the component life time. The thermal phenomena in the power electronic component can not be dissociated with the electric phenomena (losses) and fluidic phenomena (cooling). An electro-thermo-fluidic modelling method has been elaborated. The method is used to study an IGCT (Integrated Gate commutated Thyristor) 4.5 kV 4 kA in the switching cell with his water cooling system. The IGCT use a press-pack floating mount package technology. The thermal contact resistances have an important impact on the heat transfer in the package. The thermal contact resistances have been estimated with a profile-metric measure and a direct measure. To validate the method and tune the model, thermal, electric and fluidic measurements are performed in an IGCT in MW switching operation. The last chapter introduces the model applications. The model is used to study the water flow direction in the IGCT cooling system. Transient simulations are used to study the temperature fluctuation on an arc furnace melting cycle. (author)

  10. Impact of comorbidities on hospitalization costs following hip fracture.

    Science.gov (United States)

    Nikkel, Lucas E; Fox, Edward J; Black, Kevin P; Davis, Charles; Andersen, Lucille; Hollenbeak, Christopher S

    2012-01-04

    Hip fractures are common in the elderly, and patients with hip fractures frequently have comorbid illnesses. Little is known about the relationship between comorbid illness and hospital costs or length of stay following the treatment of hip fracture in the United States. We hypothesized that specific individual comorbid illnesses and multiple comorbid illnesses would be directly related to the hospitalization costs and the length of stay for older patients following hip fracture. With use of discharge data from the 2007 Nationwide Inpatient Sample, 32,440 patients who were fifty-five years or older with an isolated, closed hip fracture were identified. Using generalized linear models, we estimated the impact of comorbidities on hospitalization costs and length of stay, controlling for patient, hospital, and procedure characteristics. Hypertension, deficiency anemias, and fluid and electrolyte disorders were the most common comorbidities. The patients had a mean of three comorbidities. Only 4.9% of patients presented without comorbidities. The average estimated cost in our reference patient was $13,805. The comorbidity with the largest increased hospitalization cost was weight loss or malnutrition, followed by pulmonary circulation disorders. Most other comorbidities significantly increased the cost of hospitalization. Compared with internal fixation of the hip fracture, hip arthroplasty increased hospitalization costs significantly. Comorbidities significantly affect the cost of hospitalization and length of stay following hip fracture in older Americans, even while controlling for other variables.

  11. Effect of Temperature on the Fracture Toughness of Hot Isostatically Pressed 304L Stainless Steel

    Science.gov (United States)

    Cooper, A. J.; Brayshaw, W. J.; Sherry, A. H.

    2018-03-01

    Herein, we have performed J- Resistance multi-specimen fracture toughness testing of hot isostatically pressed (HIP'd) and forged 304L austenitic stainless steel, tested at elevated (300 °C) and cryogenic (- 140 °C) temperatures. The work highlights that although both materials fail in a pure ductile fashion, stainless steel manufactured by HIP displays a marked reduction in fracture toughness, defined using J 0.2BL, when compared to equivalently graded forged 304L, which is relatively constant across the tested temperature range.

  12. Conférence de presse | Press Conference

    CERN Multimedia

    CERN. Geneva; Bejar Alonso, Isabel

    2018-01-01

    10:00-11:00 Conférence de presse en présence de Lucio Rossi, chef du projet LHC à Haute Luminosité et Isabel Bejar Alonso, chargée de la configuration, de la qualité et des ressources du projet LHC à Haute Luminosité.

  13. The Spanish press associations, a consolidated model of professional organization / Las asociaciones de la prensa españolas, un modelo de organización profesional consolidado

    Directory of Open Access Journals (Sweden)

    Francisco Javier Paniagua Rojano - fjpaniagua@uma.es

    2008-01-01

    Full Text Available The Press Associations represent the prevailing organizational option among the Spanish journalists. At present, 50 Associations exist in Spain, specially limited to the provincial areas, but also to villages (Jerez de la Frontera, Talavera de la Reina, Santiago de Compostela, to shires (Campo de Gibraltar and even to regions, v. gr., the Unión de Periodistas Valencianos (Valencian Journalists Union. Likewise, there exist five specialized Associations; the most outstanding are the Asociación de Periodistas de Información Económica (Economic Information Association and the Asociación Española de la Prensa Deportiva (Sport Press Spanish Association. All the Associations are gathered into the Federación de Asociaciones de la Prensa de España (Federation of Spanish Press Associations. The present investigation analyzes level organization and syndication of Spanish journalists, the problems that affect to the professionals and the advantages derived from the belonging, offering information about: - Number of partners and trends registered in numbers. - Varied range of services to the professionals: the agreements with public and private corporations, labor exchanges, formative courses, paper an online magazines, etc.- Problems that affect to the professionals: the fight against working without qualification, the defense of the profession image and its values, etc. - Presence in Internet and adjustment to the new technologies.Resumen: Las asociaciones de la prensa representan la opción organizativa predominante entre los periodistas españoles. Suman, en la actualidad, un total de 50, la mayoría de ámbito provincial, aunque también las hay circunscritas a municipios (Jerez de la Frontera, Talavera de la Reina, Santiago de Compostela, a regiones (Campo de Gibraltar e incluso a comunidades autónomas, como la Unión de Periodistas Valencianos. De igual manera, existen cinco asociaciones de carácter especializado, como la Asociación de

  14. Investing in a Large Stretch Press

    Science.gov (United States)

    Choate, M.; Nealson, W.; Jay, G.; Buss, W.

    1986-01-01

    Press for forming large aluminum parts from plates provides substantial economies. Study assessed advantages and disadvantages of investing in large stretch-forming press, and also developed procurement specification for press.

  15. WordPress 3 Cookbook

    CERN Document Server

    Shreves, Ric

    2011-01-01

    This is a Packt Cookbook, which means it contains step-by-step instructions to achieve a particular goal or solve a particular problem. There are plenty of screenshots and explained practical tasks to make comprehension quick and easy. This book is not specifically for developers or programmers; rather it can be used by anyone who wants to get more out of their WordPress blog by following step-by-step instructions. A basic knowledge of PHP/XHTML/CSS/WordPress is desirable but not necessary.

  16. Net-Shape HIP Powder Metallurgy Components for Rocket Engines

    Science.gov (United States)

    Bampton, Cliff; Goodin, Wes; VanDaam, Tom; Creeger, Gordon; James, Steve

    2005-01-01

    True net shape consolidation of powder metal (PM) by hot isostatic pressing (HIP) provides opportunities for many cost, performance and life benefits over conventional fabrication processes for large rocket engine structures. Various forms of selectively net-shape PM have been around for thirty years or so. However, it is only recently that major applications have been pursued for rocket engine hardware fabricated in the United States. The method employs sacrificial metallic tooling (HIP capsule and shaped inserts), which is removed from the part after HIP consolidation of the powder, by selective acid dissolution. Full exploitation of net-shape PM requires innovative approaches in both component design and materials and processing details. The benefits include: uniform and homogeneous microstructure with no porosity, irrespective of component shape and size; elimination of welds and the associated quality and life limitations; removal of traditional producibility constraints on design freedom, such as forgeability and machinability, and scale-up to very large, monolithic parts, limited only by the size of existing HIP furnaces. Net-shape PM HIP also enables fabrication of complex configurations providing additional, unique functionalities. The progress made in these areas will be described. Then critical aspects of the technology that still require significant further development and maturation will be discussed from the perspective of an engine systems builder and end-user of the technology.

  17. Spine–hip relations in patients with hip osteoarthritis

    Science.gov (United States)

    Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah

    2018-01-01

    Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844

  18. Converter structure-based power loss and static thermal modeling of the press-pack IGBT-based three-level ANPC and HB VSCs applied to Multi-MW wind turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Munk-Nielsen, Stig; Teodorescu, Remus

    2010-01-01

    and the switch thermal performance which is determined by the converter load profile and the converter structure. In this study, the converter-structure based power loss and thermal models are developed for the medium voltage full-scale 3LANPC- VSC and 3L-HB-VSC utilizing press-pack IGBT-diode pairs......The wind turbine converters demand high power density due to nacelle space limitation and high reliability due to high maintenance cost. Once the converter topology with the semiconductor switch technology is selected, the converter power density and reliability are dependent on the component count...

  19. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Law and the Student Press.

    Science.gov (United States)

    Stevens, George E.; Webster, John B.

    Court cases and legal decisions involving the student press in the late 1960s and early 1970s are brought together in this book in order to show how the law has been applied to school officials and student journalists in high school, college, and the underground. The ten chapters cover the following topics: censorship, libel, obscenity, contempt,…

  1. Local and international press digest

    CERN Multimedia

    2008-01-01

    The following are the top stories in the Maltese and the international press today. The Times gives prominence to the Prime Minister's flying visit to Geneva yesterday, where he signed a research cooperation agreement with CERN, the European nuclear research organisation.

  2. A new hot pressing technique

    International Nuclear Information System (INIS)

    Carcey, J.

    1975-01-01

    An original hot pressing method which may be applied to ceramics, metals, and refractory powders is described. The products obtained are fine grained polycristalline materials, with homogeneous structure, very high density, unstrained and of very large dimensions (several square meters). This process equally applies to composite materials including powders, fibers, etc.. [fr

  3. Revision hip preservation surgery with hip arthroscopy: clinical outcomes.

    Science.gov (United States)

    Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J

    2014-05-01

    To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  5. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  6. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  7. Prevention of unrecognized joint penetration during internal fixation of hip fractures: a geometric model based on Steinmetz Solid.

    Science.gov (United States)

    Mao, Yujiang; Song, Jie; Wei, Jie; Wang, Manyi

    2010-01-01

    Unrecognized joint penetration (UJP) by screw penetration through the articular surface undetectable on routine anteroposterior (AP) and lateral radiographs can cause serious complications. We have developed a geometric model to analyze UJP, and methods for the prevention of the problem. A Steinmetz Solid (SS) is the overlapping portion between two identical, vertically intersecting cylinders. The AP and lateral radiographs of a femoral head (simplified as a sphere) are projections of two cylinder-shaped images. A screw that appears to be within the femoral head in fact only lies within the cylinder. A screw apparently within the femoral head on both AP and lateral images is only confined to the SS generated by two cylinders, but not necessarily confined to the femoral head itself. We have therefore analyzed UJP using a geometric model based on SS. The geometric basis of UJP lies in the fact that the SS is larger than the sphere (femoral head) with a volume ratio of 4: π. The theoretical risk of UJP for any screw therefore can be as high as 21.5% ((4-π)/4). In reality, screws are always carefully placed to ensure a distance between the screw's tip and the edge of femoral head (tip-to-edge distance, or TED). This TED effectively lowers the risk of UJP by reducing the size of the screw-confining SS. When the SS entirely fits into (internally tangential to) the femoral head, the risk of UJP approaches zero. A TED fulfilling this requirement can be regarded as safe (approximately 0.29 x femoral head radius). With a femoral head diameter of 5 cm, the safe TED is approximately 7 mm.

  8. Model for using hip-hop music for small group HIV/AIDS prevention counseling with African American adolescents and young adults.

    Science.gov (United States)

    Stephens, T; Braithwaite, R L; Taylor, S E

    1998-10-01

    Currently little attention has been directed, with the exception of peer education efforts, to constructively develop new and innovative ways to promote HIV/AIDS primary prevention among African American (AA) adolescents and young adults. With this in mind, the aim of this conceptual effort is to present a HIV/AIDS preventive counseling protocol developed for use with AA young adults that makes use of hip-hop music, a form of music popularized by young AAs. The author contend that an increased understanding of the relationships that many AA young adults have with hip-hop music may be used by disease prevention personnel to educate these populations about protective factors for HIV. Making use of hip-hop music is one strategy for integrating counseling in prevention and health maintenance. The overall implications of using hip-hop music in health promotion are unlimited. First, this method makes use of cultural relevant materials to address the educational and health needs of the target community. Second, it is grounded in an approach that serves to stimulate cooperative learning based on peer developed content. Moreover, the use of this medium can be applied to other health promotion activities such as violence/harm reduction and substance abuse prevention, upon reviews of songs for appropriate content. The authors contend that such an approach holds heuristic value in dealing with HIV/AIDS prevention among AA young adults. Additional testing of the intervention is warranted in the refinement of this innovative intervention.

  9. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.

    2015-01-01

    Social inequality appears to be increasing in many countries. We explored whether risk of hip fracture was associated with markers of inequality and whether these relationships changed with time, using data from Danish Health Registries. Methods: All patients 60 years or older with a primary hip...... fracture (ICD10: S720, S721, S722 and S729) were identified from 1 January 1995 to 31 December 2011. Hip fracture patients were matched 1:1 on age, gender and year of fracture to a non-hip fracture control. An individual's education attainment was defined as basic, secondary or higher, and their income...

  10. Finite element simulation of HIP-process to produce 3d near net shape parts

    International Nuclear Information System (INIS)

    Zadeh, M.K.

    1996-01-01

    One of the major problems when producing powder metallurgy parts through hot isostatic pressing (HIP) is the non homogeneous shrinkage of HIP-capsule during the process. This leads to time and cost consuming machining of the HIP parts. In order to reduce the machining to a minimum, one can try to simulate the HIP-process by means of numerical methods. Hereby, the part distortion can be predicted, and hence a new HIP-capsule can be designed in such a way to prevent the distortion partly or even completely. In the following, a finite element method is used, on one hand, to simulate part shrinkage during HIP process; on the other hand a method is integrated in this simulation to optimize the HIP-capsule geometry. For the determination of material dependent parameters, a mixture of theoretical and experimental methods is used. Results of simulation are verified for a complex 3d HIP part out of TiAl6V4

  11. Validity of gait parameters for hip flexor contracture in patients with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Lee Sang Hyeong

    2011-01-01

    Full Text Available Abstract Background Psoas contracture is known to cause abnormal hip motion in patients with cerebral palsy. The authors investigated the clinical relevance of hip kinematic and kinetic parameters, and 3D modeled psoas length in terms of discriminant validty, convergent validity, and responsiveness. Methods Twenty-four patients with cerebral palsy (mean age 6.9 years and 28 normal children (mean age 7.6 years were included. Kinematic and kinetic data were obtained by three dimensional gait analysis, and psoas lengths were determined using a musculoskeletal modeling technique. Validity of the hip parameters were evaluated. Results In discriminant validity, maximum psoas length (effect size r = 0.740, maximum pelvic tilt (0.710, maximum hip flexion in late swing (0.728, maximum hip extension in stance (0.743, and hip flexor index (0.792 showed favorable discriminant ability between the normal controls and the patients. In convergent validity, maximum psoas length was not significantly correlated with maximum hip extension in stance in control group whereas it was correlated with maximum hip extension in stance (r = -0.933, p Conclusions Maximum pelvic tilt, maximum psoas length, hip flexor index, and maximum hip extension in stance were found to be clinically relevant parameters in evaluating hip flexor contracture.

  12. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    Science.gov (United States)

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A press for the theater

    Directory of Open Access Journals (Sweden)

    Luciana Penna França

    2017-12-01

    Full Text Available Understanding the history of the amateur theater at the end of the XIXth century and the beginning of the XXth is possible, largely, because of the newspapers dedicated to the “theatrical affairs”. Such publications are important for the quantity and the diversity, revealing not only the place occupied by the theater in the capital, but also for the recognition of the press as a means of disclosure of plays, public education and opinion, artist projection, etc, not to mention personal affairs and requests, and the exchange of favors among managers and journalists. Even more, the press production of the dramatic amateurs clubs demonstrate the understanding of its role in the dissemination of ways to act and think beyond the stage and in the everyday life.

  14. Oxide formation and precipitation behaviors on interface of F82H steel joints during HIPing and hot pressing

    International Nuclear Information System (INIS)

    Kishimoto, H.; Ono, T.; Sakasegawa, H.; Tanigawa, H.; Ando, M.; Shibayama, T.; Kohno, Y.; Kohyama, A.

    2013-01-01

    Joining technologies for F82H steels are important issues for the development of fusion energy. The hot isostatic pressing (HIP) method is appropriate for consolidating the first wall of the blanket because of the flexibility of the shape of HIPed products. The HIP method is planned for fabricating a complex-shaped first wall component with built-in cooling channels; thus, accumulation of studies of microstructural and mechanical property changes, especially lower toughness of the HIPed joints, is essential. Present research aims to reveal the microstructural evolution of F82H joints fabricated by the HIP method compared with joints fabricated by hot pressing, focusing on the formation of oxides on the interface. F82H joints were characterized using 1/3-scale Charpy V-notch impact test, transmission electron microscope, scanning electron microscope, and electron probe analysis to survey the microstructural characteristics of the interface

  15. Pressing technology for large bottoms

    International Nuclear Information System (INIS)

    Jilek, L.

    1986-01-01

    The technology has been selected of a circular plate bent into the shape of a trough, for pressing bottoms of pressure vessels from a circular plate of large diameter. The initial sheet is first bent in the middle by heating with the edges remaining straight. These are then welded longitudinally by electroslag welding and the circular shape is flame cut. The result will be a plate with a straight surface in the middle with raised edges which may be pressed into the desired shape. In this manner it is also possible to press pressure vessel bottoms with tube couplings from plates which are thickened in the middle and drilled; additional welding is then eliminated. Deformation from heat treatment may be avoided by the use of a fixture in the shape of a ring with a groove into which is fixed the edge of the bottom. During hardening of the bottom it will be necessary to care for the withdrawal of vapours and gases which would hamper uniform cooling. Bottom hardening with the grill and the cupola downwards has been proven. Deformation which occurs during treatment may to a certain extent be removed by calibration which cannot, however, be made without special fixtures and instruments. (J.B.)

  16. [Is Mapuche ethnicity a risk factor for hip fracture in aged?].

    Science.gov (United States)

    Sapunar, Jorge; Bravo, Paulina; Schneider, Hermann; Jiménez, Marcela

    2003-10-01

    Ethnic factors are involved in the risk for osteoporosis and hip fracture. To assess the effect of Mapuche ethnicity on the risk of hip fracture. A case control study. Cases were subjects over 55 years of age admitted, during one year, for hip fracture not associated to major trauma or tumors. Controls were randomly chosen from other hospital services and paired for age with cases. The magnitude of the association between ethnicity and hip fracture was expressed as odds ratio in a logistic regression model. In the study period, 156 cases with hip fracture were admitted. The proportion of subjects with Mapuche origin was significantly lower among cases than controls (11.8 and 26.5% respectively, p Mapuche ethnicity was associated with hip fracture with an odds radio of 0.14 (p = 0.03, 95% CI 0.03-0.8). In this sample, Mapuche ethnicity is a protective factor for hip fracture.

  17. Sonographic evaluation of borderline hips in the newborn

    International Nuclear Information System (INIS)

    Rabassini, A.; Piovesan, L.; Rupeni, L.; Donadi, M.; Bacarini, L.; Gerardi, A.; Ortolani, M.

    1991-01-01

    Infant hips are classified, according to Graf, in 4 US types on the basis of the morphologic changes in both the cartilaginous and the bony roofs (type I, II, III, IV). Out of 6,000 examined hips, 170 (2.8%) were considered, which could be classified neither as type I (mature) nor as type II (delayed/immature ossification). These hips were called borderline hips. They exhibited some charecteristic US features: good bone modeling, rounded cotyle, and α angle 60 grades ±2. They were always observed during the first month of the patients' life. Anamnestic data were not specific (27.5% breech delivery, and 13% oligohydramnios); clinics sometimes overestimated tha actual anatomic development (64/170 cases with positivity of Ortolani's sign and/or restricted abduction; 25% of patients presented with no suspicious signs) Dynamic hip examination showed only physiological cranial deflection of the cartilaginous roof. Finally, borderline hips developed into type I hips in 99% of cases, within the third month of the patients' life

  18. The history of biomechanics in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Jan Van Houcke

    2017-01-01

    Full Text Available Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro, in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA. The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  19. Gluteal tendinopathy and hip osteoarthritis: Different pathologies, different hip biomechanics.

    Science.gov (United States)

    Allison, Kim; Hall, Michelle; Hodges, Paul W; Wrigley, Tim V; Vicenzino, Bill; Pua, Yong-Hao; Metcalf, Ben; Grimaldi, Alison; Bennell, Kim L

    2018-03-01

    Gluteal tendinopathy (GT) and hip osteoarthritis (OA) are the most common causes of hip pain and associated disability in older adults. Pain and altered walking biomechanics are common to both conditions. This study aimed to compare three-dimensional walking biomechanics between individuals with unilateral, symptomatic GT and HOA. Sixty individuals with symptomatic unilateral GT confirmed by magnetic-resonance-imaging and 73 individuals with symptomatic unilateral HOA (Kellgren-Lawrence Grade ≥ 2) underwent three-dimensional gait analysis. Maximum and minimum values of the external sagittal hip moment, the first peak, second peak and mid-stance minimum of the hip adduction moment (HAM), sagittal plane hip excursion and hip joint angles, pelvic obliquity and trunk lean, at the three HAM time points during stance phase of walking were compared between groups. Compared to individuals with HOA, those with GT exhibited a greater hip peak extension moment (P < 0.001) and greater HAM throughout the stance phase of walking (P = 0.01-P < 0.001), greater hip adduction (P < 0.001) and internal rotation (P < 0.01-P < 0.001) angles and lower hip flexion angles and excursion (P = 0.02 - P < 0.001). Individuals with HOA exhibited a greater forward trunk lean (P ≤ 0.001) throughout stance, and greater ipsilateral trunk lean in the frontal plane (P < 0.001) than those with GT. Despite presence of pain in both conditions, hip kinematics and kinetics differ between individuals with symptomatic unilateral GT and those with symptomatic unilateral HOA. These condition-specific impairments may be targets for optimization of management of HOA and GT. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The influence of isometric preload on power expressed during bench press in strength-trained men.

    Science.gov (United States)

    Bartolomei, Sandro; Fukuda, David H; Hoffman, Jay R; Stout, Jeffrey R; Merni, Franco

    2017-03-01

    The purpose of this study was to compare the power expressed during the bench press exercise in resistance-trained men following different pre-activation conditions. Twenty-two trained men (age 24.1 ± 1.7 years, height 178.6 ± 6.1 cm, body mass 81.1 ± 10.6 kg) completed a maximal effort bench press (1-RM) test (100.0 kg ± 8.1 kg). In a subsequent assessment, each participant performed concentric bench press movements with loads of 20%, 30%, 40% and 50% of their 1-RM preceded by either a concentric contraction (CC), a low isometric preload (LIP; 70% 1-RM) or a high isometric preload (HIP; 100% 1-RM) conditions. All movements were performed in a Smith machine with a settable quick-release device. Participants performed all three conditions in randomized fashion. Results indicated that power outputs during the bench press exercise following HIP were significantly (p < 0.05) greater than CC at 20% 1-RM (+9%), 30% 1-RM (+16%) and 40% 1-RM (+14%), and LIP at 20% 1-RM (+4%), 30% 1-RM (+20%) and 40% 1-RM (+15%). No differences were found between conditions at 50% 1-RM. Area under the force-power curve with HIP was greater (p < 0.05) than with CC and LIP. In conclusion, results of this study indicate that the use of a HIP (100% 1-RM) in trained participants results in significantly greater power output during the concentric phase of a multi-joint exercise when compared to standard concentric movement.

  1. Price in the Eye of the Beholder Book Review: Mears A. (2011) Pricing Beauty: The Making of a Fashion Model. Berkeley: University of California Press.

    OpenAIRE

    Tamara Kusimova

    2014-01-01

    This article presents a review of Ashley Mears' book “Pricing Beauty: The Making of a Fashion Model”. The book is devoted to sociological inquiry into the fashion model business. Modeling is a specific kind of market, where careers depend on judgments about individual appearance. Making aesthetic decisions usually seems intuitive: in distinguishing the “beautiful” from the “unattractive”, people commonly rely on subjective opinions. How is it possible to define the value of how a human looks ...

  2. Hip-Hop Education Resources

    Science.gov (United States)

    Hall, Marcella Runell

    2009-01-01

    Hip-hop music and culture are often cited as being public pedagogy, meaning the music itself has intrinsic educational value. Non-profit organizations and individual educators have graciously taken the lead in utilizing hip-hop to educate. As the academy continues to debate its effectiveness, teachers and community organizers are moving forward.…

  3. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  4. The Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Varnum, Claus; Pedersen, Alma Becic

    2016-01-01

    AIM OF DATABASE: The aim of the Danish Hip Arthroplasty Register (DHR) is to continuously monitor and improve the quality of treatment of primary and revision total hip arthroplasty (THA) in Denmark. STUDY POPULATION: The DHR is a Danish nationwide arthroplasty register established in January 1995...

  5. Hip sonography in the newborn

    International Nuclear Information System (INIS)

    Riboni, G.; Serantoni, S.; De Simoni, M.; Bascape', P.; Facchini, R.; Pirovano, G.

    1991-01-01

    The authors report the data relative to 1507 cases studied with clinical and US examinations, in the neonatal period, in order to exclude hip dysplasia dislocation. US examination was carried out according to Graf's technique and the newborns were classified according to US hip type, to clinical examination and to possible risk factors. The patients were included in a protocol including orthopedic and US controls. Seventeen treated infants were considered as pathologic. Ten of them had IIc or D hips ar birth; the other 7, with IIa hips at birth, presented a X-ray pathologic hip after the 4th months of life. At about one year of age all infants could normally walk, excpet for one who was being treated with herness. No statistically significant differences were observed between the number of pathologic infants in the risk group (1.7%) and that in the no-risk group (0.8%). Clinical examination of the newborn has low sensitivity in detecting pathologic hips. On the basis of their results, thw authors belive US examination of the newborn to be a valuable screening method to diagnose hip dysplasia/dislocation. Moreover, Graf's morphologic method is the best one for US screening of the hip in the neonatal period

  6. Influence of surface treatment of yttria-stabilized tetragonal zirconia polycrystal with hot isostatic pressing on cyclic fatigue strength.

    Science.gov (United States)

    Iijima, Toshihiko; Homma, Shinya; Sekine, Hideshi; Sasaki, Hodaka; Yajima, Yasutomo; Yoshinari, Masao

    2013-01-01

    Hot isostatic pressing processed yttria-stabilized tetragonal zirconia polycrystal (HIP Y-TZP) has the potential for application to implants due to its high mechanical performance. The aim of this study was to investigate the influence of surface treatment of HIP Y-TZP on cyclic fatigue strength. HIP Y-TZP specimens were subjected to different surface treatments. Biaxial flexural strength was determined by both static and cyclic fatigue testing. In the cyclic fatigue test, the load was applied at a frequency of 10 Hz for 10(6) cycles in distilled water at 37°C. The surface morphology, roughness, and crystal phase of the surfaces were also evaluated. The cyclic fatigue strength (888 MPa) of HIP Y-TZP with sandblasting and acid-etching was more than twice that of Y-TZP as specified in ISO 13356 for surgical implants (320 MPa), indicating the clinical potential of this material.

  7. Verification of the effect of surface preparation on Hot Isostatic Pressing diffusion bonding joints of CLAM steel

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yanyun [University of Science and Technology of China, Hefei, Anhui 230027 (China); Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Li, Chunjing, E-mail: chunjing.li@fds.org.cn [Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Huang, Bo; Liu, Shaojun [Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Huang, Qunying [University of Science and Technology of China, Hefei, Anhui 230027 (China); Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2014-12-15

    Hot Isostatic Pressing (HIP) diffusion bonding with CLAM steel is the primary candidate fabrication technique for the first wall (FW) of DFLL-TBM. Surface state is one of the key factors for the joints quality. The effect of surface state prepared with grinder and miller on HIP diffusion bonding joints of CLAM steel was investigated. HIP diffusion bonding was performed at 140 MPa and 1373 K within 3 h. The mechanical properties of the joints were investigated with instrumented Charpy V-notch impact tests and the microstructures of the joints were analyzed with scanning electron microscopy (SEM). The results showed that the milled samples with fine surface roughness were more suitable for CLAM steel HIP diffusion bonding.

  8. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H.; Streekstra, G.J.; Maas, M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Boomsma, M.F.; Osch, J.A.C. van [Department of Radiology, Zwolle (Netherlands); Vlassenbroek, A. [Philips Medical Systems, Brussels (Belgium); Milles, J. [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A. [Department of Innovation and Science, Zwolle (Netherlands); Slump, C.H. [University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-05-15

    To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI{sub vol}: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose{sup 4} level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose{sup 4} in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose{sup 4} in the CT imaging of a THA phantom. (orig.)

  9. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  10. Experimentally induced cam impingement in the sheep hip.

    Science.gov (United States)

    Siebenrock, Klaus A; Fiechter, Ruth; Tannast, Moritz; Mamisch, Tallal C; von Rechenberg, Brigitte

    2013-04-01

    Sheep hips have a natural non-spherical femoral head similar to a cam-type deformity in human beings. By performing an intertrochanteric varus osteotomy, cam-type femoro-acetabular impingement (FAI) during flexion can be created. We tested the hypotheses that macroscopic lesions of the articular cartilage and an increased Mankin score (MS) can be reproduced by an experimentally induced cam-type FAI in this ovine in vivo model. Furthermore, we hypothesized that the MS increases with longer ambulatory periods. Sixteen sheep underwent unilateral intertrochanteric varus osteotomy of the hip with the non-operated hip as a control. Four sheep were sacrificed after 14, 22, 30, and 38-weeks postoperatively. We evaluated macroscopic chondrolabral alterations, and recorded the MS, based on histochemical staining, for each ambulatory period. A significantly higher prevalence of macroscopic chondrolabral lesions was found in the impingement zone of the operated hips. The MS was significantly higher in the acetabular/femoral cartilage of the operated hips. Furthermore, these scores increased as the length of the ambulatory period increased. Cam-type FAI can be induced in an ovine in vivo model. Localized chondrolabral degeneration of the hip, similar to that seen in humans (Tannast et al., Clin Orthop Relat Res 2008; 466: 273-280; Beck et al., J Bone Joint Surg Br 2005; 87: 1012-1018), can be reproduced. This experimental sheep model can be used to study cam-type FAI. Copyright © 2012 Orthopaedic Research Society.

  11. Hot isostatic pressing of nanosized WC-Co hardmetals

    International Nuclear Information System (INIS)

    Azcona, I.; Ordonez, A.; Sanchez, J.M.; Castro, F.; Dominguez, L.

    2001-01-01

    A new technique based on hot isostatic pressing (HIP) has been developed to produce dense nanosized WC-Co hardmetals without the addition of grain growth inhibitors. The glass encapsulation process is the key for the effective application of isostatic pressure at temperatures well below those usually required for reaching the closed porosity state in the WC-Co system. Fully dense WC-Co samples with cobalt contents ranging from 10 to 12 wt. % have been obtained by this technique at temperatures between 1000 o C and 1200 o C with 150 MPa of applied isostatic pressure for 30 minutes. The role of isostatic pressure on the activation of densification mechanisms is discussed. (author)

  12. WordPress Website Development

    OpenAIRE

    Lassila, Joonas

    2016-01-01

    The aim of this Bachelor’s thesis was to develop a WordPress mobile-first style website for the customer, Pohjois-Suomen Pesis. The main purpose of the development was to learn website designing principles and create a responsive website for the mobile and desktop platforms. The development process began defining the requirements of the website and creating the requirements document. Then next step was learning how to design a website layout and to choose the colour scheme for the site. T...

  13. Smashing WordPress Beyond the Blog

    CERN Document Server

    Hedengren, Thord Daniel

    2012-01-01

    The ultimate guide to WordPress, from the world's most popular resource for web designers and developers As one of the hottest tools on the web today for creating a blog, WordPress has evolved to be much more that just a blogging platform and has been pushed beyond its original purpose. With this new edition of a perennially popular WordPress resource, Smashing Magazine offers you the information you need so you can maximize the potential and power of WordPress. WordPress expert Thord Daniel Hedengren takes you beyond the basic blog to show you how to leverage the capabilities of WordPress to

  14. Teach yourself visually WordPress

    CERN Document Server

    Majure, Janet

    2012-01-01

    Get your blog up and running with the latest version of WordPress WordPress is one of the most popular, easy-to-use blogging platforms and allows you to create a dynamic and engaging blog, even if you have no programming skills or experience. Ideal for the visual learner, Teach Yourself VISUALLY WordPress, Second Edition introduces you to the exciting possibilities of the newest version of WordPress and helps you get started, step by step, with creating and setting up a WordPress site. Author and experienced WordPress user Janet Majure shares advice, insight, and best practices for taking full

  15. Concept Design of Movable Beam of Hydraulic Press

    Directory of Open Access Journals (Sweden)

    Li Yancong

    2017-01-01

    Full Text Available The hydraulic press movable beam is one of the key components of the hydraulic press; its design quality impacts the accuracy of the workpiece that the press suppressed. In this paper, first, with maximum deflection and material strength as constraints, mechanical model of the movable beam is established; next, the concept design model of the moveable beam structure is established; the relationship among the force of the side cylinder, the thickness of the inclined plate, outer plate is established also. Taking movable beam of the 100MN type THP10-10000 isothermal forging hydraulic press as an example, the conceptual design result is given. This concept design method mentoned in the paper has general meaning and can apply to other similar product design.

  16. Conceptual design for remote handling methods using the HIP process in the Calcine Immobilization Program

    International Nuclear Information System (INIS)

    Berry, S.M.; Cox, C.G.; Hoover, M.A.

    1994-03-01

    This report recommends the remote conceptual design philosophy for calcine immobilization using the hot isostatic press (HIP) process. Areas of remote handling operations discussed in this report include: (1) introducing the process can into the front end of the HIP process, (2) filling and compacting the calcine/frit mixture into the process can, (3) evacuating and sealing the process can, (4) non-destructive testing of the seal on the process can, (5) decontamination of the process can, (6) HIP furnace loading and unloading the process can for the HIPing operation, (7) loading an overpack canister with processed HIP cans, (8) sealing the canister, with associated non-destructive examination (NDE) and decontamination, and (9) handling canisters for interim storage at the Idaho Chemical Processing Plant (ICPP) located on the Idaho National Engineering Laboratory (INEL) site

  17. The irreducible floating hip: a unique presentation of a rare injury.

    Science.gov (United States)

    Tiedeken, Nathan C; Saldanha, Vilas; Handal, John; Raphael, James

    2013-10-04

    A floating hip injury occurs in the setting of poly-trauma and is a rare and difficult problem to manage. Floating hip injuries require vigilant attention not only to the osseous injuries but also the surrounding compartments and soft tissue envelope. We report the case of a 35-year-old male with a lower extremity posterior wall acetabular fracture, ipsilateral femoral shaft fracture and a postero-superior hip dislocation. Closed reduction failed, necessitating an open reduction internal fixation of his hip dislocation and acetabular fracture. The patient then developed a thigh compartment syndrome requiring a fasciotomy. Despite the obvious bony injuries, orthopedic surgeons must be vigilant of the neurovascular structures and soft tissues that have absorbed a great amount of force. A treatment plan should be formulated based on the status of the overlying soft tissue, fracture pattern and the patient's physiologic stability. Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2013.

  18. Ductile Fracture Behaviour of Hot Isostatically Pressed Inconel 690 Superalloy

    Science.gov (United States)

    Cooper, A. J.; Brayshaw, W. J.; Sherry, A. H.

    2018-04-01

    Herein we assess the differences in Charpy impact behavior between Hot Isostatically Pressed and forged Inconel 690 alloy over the temperature range of 300 °C to - 196 °C. The impact toughness of forged 690 exhibited a relatively small temperature dependence, with a maximum difference of ca. 40 J measured between 300 °C and - 196 °C, whereas the HIP'd alloy exhibited a difference of approximately double that of the forged alloy over the same temperature range. We have conducted Charpy impact testing, tensile testing, and metallographic analyses on the as-received materials as well as fractography of the failed Charpy specimens in order to understand the mechanisms that cause the observed differences in material fracture properties. The work supports a recent series of studies which assess differences in fundamental fracture behavior between Hot Isostatically Pressed and forged austenitic stainless steel materials of equivalent grades, and the results obtained in this study are compared to those of the previous stainless steel investigations to paint a more general picture of the comparisons between HIP vs forged material fracture behavior. Inconel 690 was selected in this study since previous studies were unable to completely omit the effects of strain-induced martensitic transformation at the tip of the Chary V-notch from the fracture mechanism; Inconel 690 is unable to undergo strain-induced martensitic transformation due to the alloy's high nickel content, thereby providing a sister study with the omission of any martensitic transformation effects on ductile fracture behavior.

  19. Pelvic orientation and assessment of hip dysplasia in adults

    DEFF Research Database (Denmark)

    Jacobsen, S.; Holm, S.S.; Lund, B.

    2004-01-01

    on the measurements of radiographic indices of hip dysplasia. MATERIAL AND METHODS: We investigated the effect of varying pelvic orientation on radiographic measurements of acetabular dysplasia using a cadaver model. Results from the cadaver study were used to validate the radiographic assessments of acetabular...... radiograph was recorded at each 3 degrees increment. The most widely used radiographic parameters of hip dysplasia were assessed. 2) Critical limits of acceptable rotation and inclination/reclination of pelvises were determined on 4151 standing, standardised pelvic radiographs of the CCHS cohort. RESULTS......BACKGROUND: The study was performed to qualify the source material of 4151 pelvic radiographs for the research into the relationship between unrecognised childhood hip disorders and the development of hip osteoarthrosis, and to investigate the effect of varying degrees of pelvic tilt and rotation...

  20. The pelvis and hips

    International Nuclear Information System (INIS)

    Berquist, T.H.; Coventry, M.B.

    1985-01-01

    Radiographic evaluation of joint replacements requires close communication between the radiologist and referring physician. Routine films, radioisotope scans, and subtraction arthrography (including aspiration and injection of the pseudocapsule) may be indicated in different clinical situations. This paper summarizes the accuracy of these modalities. Most patients present with pain. One must exclude loosening, infection, and other problems. The arthrogram is most useful in defining anatomy and most causes of hip pain. Culture studies and diagnostic injections add to the versatility of subtraction arthrography and increase its accuracy. If plain films are negative, a Tc-99m scan can be obtained. If this is negative, loosening is unlikely. If pain persists or if the scan is positive, an arthrogram should be performed. Pain may be secondary to bursitis rather than loosening, and the arthrogram will assist in diagnosis and treatment. When films suggest loosening, arthrography is the procedure of choice to confirm the diagnosis and to exclude infection

  1. Hip complications following chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J. [Saint Bartholomew`s Hospital, London (United Kingdom)

    1995-12-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author).

  2. Hip complications following chemoradiotherapy

    International Nuclear Information System (INIS)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J.

    1995-01-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author)

  3. Pellet presses for remote fuel fabrication

    International Nuclear Information System (INIS)

    Densley, P.J.

    1978-01-01

    Two types of mechanical presses are being tested from the remote operation and remote maintenance aspects. Results will be used to recommend the type of press and design considerations required for operation in a remotely operated and maintained process line

  4. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    Science.gov (United States)

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no

  5. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  6. Traumatic injuries of the hip.

    LENUS (Irish Health Repository)

    Marshall, Nina

    2009-11-01

    Traumatic lesions of the hip in athletes may be clinically challenging because of the overlap in clinical presentation due to differing pathologies and the presence of multiple injuries. Imaging of the hip in the athlete has undergone a recent resurgence of interest and understanding related to the increasing accessibility and use of hip arthroscopy, which expands the treatment options available for intra-articular pathology. MR imaging and MR arthrography have a unique role in diagnosis of these pathologies, guiding the surgeon, arthroscopist, and referring clinician in their management of bony and soft tissue injury.

  7. A preliminary examination of the diagnostic value of deep learning in hip osteoarthritis.

    Directory of Open Access Journals (Sweden)

    Yanping Xue

    Full Text Available Hip Osteoarthritis (OA is a common disease among the middle-aged and elderly people. Conventionally, hip OA is diagnosed by manually assessing X-ray images. This study took the hip joint as the object of observation and explored the diagnostic value of deep learning in hip osteoarthritis. A deep convolutional neural network (CNN was trained and tested on 420 hip X-ray images to automatically diagnose hip OA. This CNN model achieved a balance of high sensitivity of 95.0% and high specificity of 90.7%, as well as an accuracy of 92.8% compared to the chief physicians. The CNN model performance is comparable to an attending physician with 10 years of experience. The results of this study indicate that deep learning has promising potential in the field of intelligent medical image diagnosis practice.

  8. Predicting Early Mortality After Hip Fracture Surgery: The Hip Fracture Estimator of Mortality Amsterdam.

    Science.gov (United States)

    Karres, Julian; Kieviet, Noera; Eerenberg, Jan-Peter; Vrouenraets, Bart C

    2018-01-01

    Early mortality after hip fracture surgery is high and preoperative risk assessment for the individual patient is challenging. A risk model could identify patients in need of more intensive perioperative care, provide insight in the prognosis, and allow for risk adjustment in audits. This study aimed to develop and validate a risk prediction model for 30-day mortality after hip fracture surgery: the Hip fracture Estimator of Mortality Amsterdam (HEMA). Data on 1050 consecutive patients undergoing hip fracture surgery between 2004 and 2010 were retrospectively collected and randomly split into a development cohort (746 patients) and validation cohort (304 patients). Logistic regression analysis was performed in the development cohort to determine risk factors for the HEMA. Discrimination and calibration were assessed in both cohorts using the area under the receiver operating characteristic curve (AUC), the Hosmer-Lemeshow goodness-of-fit test, and by stratification into low-, medium- and high-risk groups. Nine predictors for 30-day mortality were identified and used in the final model: age ≥85 years, in-hospital fracture, signs of malnutrition, myocardial infarction, congestive heart failure, current pneumonia, renal failure, malignancy, and serum urea >9 mmol/L. The HEMA showed good discrimination in the development cohort (AUC = 0.81) and the validation cohort (AUC = 0.79). The Hosmer-Lemeshow test indicated no lack of fit in either cohort (P > 0.05). The HEMA is based on preoperative variables and can be used to predict the risk of 30-day mortality after hip fracture surgery for the individual patient. Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

  9. Primary total hip replacement versus hip resurfacing - hospital considerations.

    Science.gov (United States)

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  10. Press to compress contaminated wastes drums

    International Nuclear Information System (INIS)

    Prevost, J.

    1993-01-01

    This patent describes a press for contaminated wastes drums pressing. The press is made of a structure comprising a base and an upper stringer bind to the base by vertical bearers, a compression system comprising a main cylinder and a ram, connected to the upper stringer

  11. Microstructure in HIP-bonded F82H steel and its mechanical properties after irradiation

    International Nuclear Information System (INIS)

    Furuya, K.; Wakai, E.

    2006-01-01

    A first primary blanket structure is composed of the low-activation steel, e.g. F82H, and is fabricated by using a solid hot isostatic pressing (HIP) bonding method. A partial mock-up of such a blanket structure was successfully fabricated. The tensile specimen including HIP-bonded region possessed a sufficient strength and elongation under a non-irradiated condition as reported in our previous studies. In this study, the microstructures of HIP interface before irradiation were observed by a TEM, and the effects of irradiation on mechanical properties of the HIP-bonded region were also examined. TEM observation and elemental analysis of the HIP-bonded region before the irradiation were performed by using a FE-TEM of HF-2000 equipped with EDX spectroscopy. Tensile specimens (type SS-3) were prepared from a HIP-bonded region and a plate region of the mock-up block. Neutron irradiation was performed up to about 1.9 dpa at about 523 K in JMTR. After the irradiation, tensile test was performed at temperatures of 295 and 523 K. After the tensile test, OM observation at the rupture region and SEM observation at the fracture surface were conducted, respectively. TEM observation and analytical results revealed that the HIP interface possessed many precipitates, and enriched peak spectrum of chromium was detected from the precipitates. In addition, aspect of the spectrum was qualitatively equivalent to that of M23C6 in grain boundaries of F82H steel. In result, the HIP boundary has many M23C6 which were generally seen in grain boundaries of F82H steel, and it can be mentioned that the HIP interface is, in this sense, a new grain boundary. Obvious HIP boundary was seen at rupture region of tensile specimens sampled from the HIP-bonded region, by the macroscopic observation. It means that rupture do not occur in the HIP interface. In result, it can be mentioned that bondability of the HIP interfaces is kept under the irradiation and testing conditions. The strength and

  12. Grading and quantification of hip osteoarthritis severity by analyzing the spectral energy distribution of radiographic hip joint space

    International Nuclear Information System (INIS)

    Boniatis, I; Costaridou, L; Panayiotakis, G; Panagiotopoulos, E

    2009-01-01

    An image analysis system is proposed for the assessment of hip osteoarthritis (OA) severity. Sixty four hips (18 normal, 46 osteoarthritic), corresponding to 32 patients of unilateral or bilateral hip OA were studied. Employing custom developed software, 64 Region Of Interest (ROI) images of Hip Joint Spaces (HJSs) were delineated on patients' digitized radiographs. The Fourier spectrum of each HJS-ROI was computed and expressed in polar coordinates. Spectral signatures, quantifying the radial and angular distribution of HJS spectral energy were formed. Signature descriptors were generated and utilized in the design of a two-level hierarchical decision tree, used for the grading of the severity of the disease. Accordingly, at Level 1, implemented by a multiple classifier system, the discrimination between normal and osteoarthritic hips was performed. At Level 2, the hips that had been successfully characterized as osteoarthritic at Level 1, were further characterized as of 'Mild / Moderate' or 'Severe' OA, by the Bayes classifier. A signature descriptors based regression model was designed, so as to quantify OA-severity. The system graded OA reliably, given that the accomplished classification accuracies for Level 1 and Level 2 were 98.4% and 100%, respectively. OA-severity values, expressed by HJS-narrowing, correlated highly (r = 0.9, p < 0.001) with values predicted by the model. The system may contribute to OA-patient management.

  13. IDEAL: ACADEMIC PRESS JOURNALS ONLINE

    CERN Multimedia

    The Library

    2001-01-01

    All Academic Press journals are available online to CERN users for a test period which will last until the end of July. The service 'IDEALIBRARY' includes 174 scientific journals that cover several domains, ranging from engineering to mathematics, computing and physics. Titles covered are among others 'Atomic Data and Nuclear Data Tables', 'Nuclear Data Sheets', 'Annals of Physics', 'Journal of Parallel and Distributed Computing'. Reference citations present in each article are linked to the corresponding full text, when the latter is published by a member of the CrossRef consortium (members are: Elsevier, APS, AIP and others). Therefore, the navigation between articles and references is uninterrupted. A search engine allows queries by author, title and publication year. See http://www.idealibrary.com. At present the Library is evaluating a site license offer proposed by the publisher.

  14. Danish Hip Arthroscopy Registry (DHAR)

    DEFF Research Database (Denmark)

    Lund, Bent; Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten

    2017-01-01

    The Danish Hip Arthroscopy Registry (DHAR) was initiated in January 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the first registry based outcome data of a national population with radiological and clinical femoroacetabular impingement (FAI......) undergoing hip arthroscopic treatment. Our primary hypothesis was that patients undergoing hip arthroscopy would improve significantly in pain, quality of life and sports related outcome measurements in Patient Related Outcome Measures (PROM). Peri-operative data and Patient Reported Outcome Measures (PROM......-5 D demonstrated improvement after 1 and 2 years from 0.66 pre-op to 0.78 at 2 years. HSAS improved significantly from 2.5 to 3.3. Pain score data demonstrated improvement in NRS-rest 39 to 17 and NRS Walk 49 to 22 at follow-up. We conclude that patients with FAI undergoing hip arthroscopy...

  15. Stability of Uncemented Cups - Long-Term Effect of Screws, Pegs and HA Coating: A 14-Year RSA Follow-Up of Total Hip Arthroplasty.

    Science.gov (United States)

    Otten, Volker T C; Crnalic, Sead; Röhrl, Stephan M; Nivbrant, Bo; Nilsson, Kjell G

    2016-01-01

    Screws, pegs and hydroxyapatite-coating are used to enhance the primary stability of uncemented cups. We present a 14-year follow-up of 48 hips randomized to four groups: press-fit only, press-fit plus screws, press-fit plus pegs and hydroxyapatite-coated cups. Radiostereometric migration measurements showed equally good stability regardless cup augmentation. The mean wear rate was high, 0.21 mm/year, with no differences between the groups. Seven hips had radiographical osteolysis but only in hips with augmented cups. Cups without screw-holes compared with cups with screw-holes resulted in better clinical outcome at the 14-year follow-up. Thus, augmentation of uncemented cups with screws, pegs, or hydroxyapatite did not appear to improve the long-term stability compared with press-fit only. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The epidemiology of hip fractures across western Victoria, Australia.

    Science.gov (United States)

    Holloway, Kara L; Sajjad, Muhammad A; Mohebbi, Mohammadreza; Kotowicz, Mark A; Livingston, Patricia M; Khasraw, Mustafa; Hakkennes, Sharon; Dunning, Trisha L; Brumby, Susan; Page, Richard S; Pedler, Daryl; Sutherland, Alasdair; Venkatesh, Svetha; Brennan-Olsen, Sharon L; Williams, Lana J; Pasco, Julie A

    2018-03-01

    Hip fractures are associated with considerable morbidity and mortality. Hip fracture incidence varies across different levels of accessibility/remoteness and socioeconomic status (SES). As part of the Ageing, Chronic Disease and Injury Study, we aimed to map the pattern of hip fractures across the western region of the Australian state of Victoria, which contains a range of remoteness levels and SES. Data on hip fractures resulting in hospital admission were extracted from the Victorian Admitted Episodes Dataset (VAED) for men and women aged 40+years during 2010-2013 inclusive. An age-adjusted incidence rate (per 10,000population/year) was calculated for the entire region. Crude incidence rates and length of acute care hospital stay (excluding rehabilitation) were calculated for each Local Government Area (LGA). The impact of aggregated age, accessibility/remoteness index of Australia (ARIA) and SES on hip fracture rates aggregated across LGAs was determined using Poisson regression. For men, the age-standardised rate of hospitalisations for hip fracture across the whole region was 19.2 per 10,000population/year (95%CI 18.0-20.4) and for women, 40.0 (95%CI 38.3-41.7). The highest incidence rates for both sexes occurred in the less accessible LGAs of Yarriambiack and Hindmarsh, as well as the LGA with the lowest SES, Central Goldfields. In both sexes, approximately two thirds of individuals were discharged from acute hospital care within 14days. Increasing age, higher remoteness and lower SES were all associated with higher hip fracture rates. Crude incidence rates varied by location. Given that a high proportion of patients had acute hospital care of ≤14days, and accessibility and SES were associated with hip fracture rates, these results can inform policy and provide a model for other groups to conduct similar research in their local environment. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Professional WordPress design and development

    CERN Document Server

    Williams, Brad; Stern, Hal

    2014-01-01

    The highest rated WordPress development and design book on the market is back with an all new third edition. Professional WordPress is the only WordPress book targeted to developers, with advanced content that exploits the full functionality of the most popular CMS in the world. Fully updated to align with WordPress 4.1, this edition has updated examples with all new screenshots, and full exploration of additional tasks made possible by the latest tools and features. You will gain insight into real projects that currently use WordPress as an application framework, as well as the basic usage a

  18. Imaging of the hip

    International Nuclear Information System (INIS)

    Karantanas, A.

    2012-01-01

    Full text: Standard radiographs represent the basic tool of hip joint imaging. For detailed analysis of abnormalities related to bone marrow, articular cartilage, labrum and periarticular soft tissues, MRI has become the method of choice. MR arthrography is superior to standard MRI with regard to depicting the intra-articular abnormalities. CT is supporting plain radiographs for accurate depiction of subtle bone details. Ultrasound is commonly used in postoperative hematoma, bursitis, initial diagnosis of cysts and solid soft tissue tumors as well as for image guided injections and biopsies. Bone scintigraphy is suitable for the mapping of multifocal disease, such as osseous metastatic deposits. PET and PET/CT may be able to differentiate malignant neoplasm and infection from other abnormalities. A common disorder often requested for evaluation, is osteoarthritis. MRI is able to depict early degenerative changes which are occult on plain radiographs. CT- or MR arthrography provide a better evaluation of these changes but should only be performed in cases in which conservative surgery is considered to offer a significant clinical improvement for the patient. These cases include cam type femoroacetabular impingement and traumatic chondrolysis. MRI is an imaging technique that allows direct visualization of the bone marrow. Marrow disorders of the hip may induce a variety of imaging findings and frequently are not detected by conventional radiographic techniques until they have reached an advanced clinical stage. The excellent spatial and contrast resolution provided by MRI facilitates early detection and evaluation of various disorders allowing thus prompt treatment. Imaging findings may alter or guide the correct treatment. In addition, the association of marrow changes and pain such as in osteonecrosis and osteoarthritis is clinically relevant. For imaging the bone marrow, we use a combination of pulse sequences, including T1-w spin echo, PD/T2-w turbo spin echo

  19. Hip Hip Hurrah! Hip size inversely related to heart disease and total mortality

    DEFF Research Database (Denmark)

    Heitmann, B L; Lissner, L

    2011-01-01

    During the past decade a series of published reports have examined the value of studying the relation between hip circumferences and cardiovascular end points. Specifically, in a series of recent studies the independent effects of hip circumference have been studied after adjustment for general o...... for women than men, but is evident in both genders. In this 'viewpoint', we wish to draw attention to the emerging body of evidence and to encourage researchers to continue collecting measures of lower body size in their surveys....... obesity and/or waist circumference. These studies have been remarkable in terms of their consistency, and in the unexpected finding of an adverse effect of small hip size, after statistically correcting for differences in general and abdominal size. The hazard related to a small hip size may be stronger...

  20. RELATIONSHIP BETWEEN COMPACTING PRESSURE AND CONDITIONS IN PRESSING CHAMBER DURING BIOMASS PRESSING

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2016-02-01

    Full Text Available In this paper, we will present the impact of the conditions in pressing chambers during the pressing of wooden briquettes. The conditions in pressing chambers can significantly impact the resulting compacting pressure required for the pressing of briquettes. In the introduction, we show which parameters of the pressing chamber during pressing can impact the resulting compacting pressure. The experiment results which are shown in this paper described the detected impact of some important pressing chamber parameters. This experiment aims to detect the pressing chamber length impact and the impact of the way of pressing. By setting the pressing conditions, we will be able to achieve the suitable resulting compacting pressure with respect to the required final briquettes quality.

  1. Towards a more responsible press

    Directory of Open Access Journals (Sweden)

    Taimur ul Hassan

    2012-12-01

    Full Text Available The article analyses Pakistan’s newspapers’ performance with regard to civil society in2003 by using content analysis approach. There is no gainsaying that a strong civil society guaranteesa strong democracy. In Pakistan, spells of military rule have stunted the growth of democracy,adversely affecting civil society. Media too has suffered as a result. Normative theories of media callfor laying down norms and conventions for media. In democracy, all sections of society should berepresented in media. In Pakistan’s case, due to military regimes and quasi democratic governments,combined with the demands of market economy, the media have largely not been able to fulfill thisresponsibility towards society. Social Responsibility demands that the media must fulfill itsresponsibility towards society, while giving a free space to all voices of society. In Pakistan, whethernewspapers played that role in 2003 when civil society had accelerated its campaign to end honorkillings and crimes against women is investigated. The findings show that newspapers did supportcivil society, showing a gradual movement towards a more responsible press.

  2. Press Advertising – Varieties and Sub-Varieties. Methods of Promoting the Press

    OpenAIRE

    Mikosz, Joanna

    2016-01-01

    In the text entitled “Press advertising – varieties and sub-varieties. Methods of promoting the press”, the author discusses press advertising, which is a fast developing mass-media phenomenon. Modernity has granted press advertising a high quality of print and paper, as well as Infinite possibilities of combining various promotional forms with the press. The author argues that press advertising is one of the best ways in which a company can communicate with the market. Its advantage is, abov...

  3. Femoral Neck Strain during Maximal Contraction of Isolated Hip-Spanning Muscle Groups

    Directory of Open Access Journals (Sweden)

    Saulo Martelli

    2017-01-01

    Full Text Available The aim of the study was to investigate femoral neck strain during maximal isometric contraction of the hip-spanning muscles. The musculoskeletal and the femur finite-element models from an elderly white woman were taken from earlier studies. The hip-spanning muscles were grouped by function in six hip-spanning muscle groups. The peak hip and knee moments in the model were matched to corresponding published measurements of the hip and knee moments during maximal isometric exercises about the hip and the knee in elderly participants. The femoral neck strain was calculated using full activation of the agonist muscles at fourteen physiological joint angles. The 5%±0.8% of the femoral neck volume exceeded the 90th percentile of the strain distribution across the 84 studied scenarios. Hip extensors, flexors, and abductors generated the highest tension in the proximal neck (2727 με, tension (986 με and compression (−2818 με in the anterior and posterior neck, and compression (−2069 με in the distal neck, respectively. Hip extensors and flexors generated the highest neck strain per unit of joint moment (63–67 με·m·N−1 at extreme hip angles. Therefore, femoral neck strain is heterogeneous and muscle contraction and posture dependent.

  4. Microstructure and properties of diffusion bonded Ti-6Al-4V parts using brazing-assisted hot isostatic pressing

    International Nuclear Information System (INIS)

    Wu, Z.; Mei, J.; Voice, W.; Beech, Steve; Wu, X.

    2011-01-01

    Highlights: → A low cost method of diffusion bonding has been developed for complex-shaped components of Ti6Al4V. → Vacuum brazing has been used to seal the periphery to allow encapsulation-free HIPping. → The tensile properties of the bonds are comparable with those of the bulk material, but the fatigue life was slightly reduced. - Abstract: Ti-6Al-4V couples have been diffusion bonded by hot isostatic pressing (HIPping) after vacuum brazing was used to seal the periphery of the bonding samples so that no encapsulation was required during HIPping. Analytical scanning electron microscopy was used to assess the microstructure of the HIPped interface and tensile and fatigue properties of bonded samples were compared with those of the bulk starting material. The tensile properties of the bonds were shown to be comparable with those of the bulk material, but the fatigue life was slightly downgraded. The fatigue fractures were initiated by inclusions on the bonding interface, caused by contamination before bonding, but the fatigue cracks did not propagate along the bonding interface indicating a strong bond. It is concluded that this technique of vacuum brazing plus HIPping could be used for encapsulation-free HIPping to produce complex-shaped components.

  5. Osteochondritis Dissecans of the Hip

    International Nuclear Information System (INIS)

    Linden, B.; Jonsson, K.; Redlund-Johnell, I.

    2003-01-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended

  6. Osteochondritis Dissecans of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Linden, B. [Hoeglands Hospital, Eksjoe (Sweden). Dept. of Orthopedic Surgery; Jonsson, K. [Univ. Hospital, Lund (Sweden). Center for Medical Imaging and Physiology; Redlund-Johnell, I. [Univ. Hospital, Malmoe (Sweden). Dept. of Diagnostic Radiology

    2003-03-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended.

  7. Smashing WordPress Beyond the Blog

    CERN Document Server

    Hedengren, Thord Daniel

    2011-01-01

    Smashing WordPress shows you how to utilize the power of the WordPress platform, and provides a creative spark to help you build WordPress-powered sites that go beyond the obvious. The second edition of Smashing WordPress has been updated for WordPress 3.1+, which includes internal, custom post types, the admin bar, and lots of other useful new features. You will learn the core concepts used to post types, the admin bar, and lots of other useful new features. You will learn the core concepts used to build just about anything in WordPress, resulting in fast deployments and greater design flexib

  8. Emerging topics on the hip: Ligamentum teres and hip microinstability

    International Nuclear Information System (INIS)

    Cerezal, Luis; Arnaiz, Javier; Canga, Ana; Piedra, Tatiana; Altónaga, José R.; Munafo, Ricardo; Pérez-Carro, Luis

    2012-01-01

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability.

  9. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

    Science.gov (United States)

    O'Dwyer Lancaster-Jones, O; Williams, S; Jennings, L M; Thompson, J; Isaac, G H; Fisher, J; Al-Hajjar, M

    2017-09-23

    The aim of this study was to develop a preclinical in vitro method to predict the occurrence and severity of edge loading condition associated with the dynamic separation of the centres of the head and cup (in the absence of impingement) for variations in surgical positioning of the cup. Specifically, this study investigated the effect of both the variations in the medial-lateral translational mismatch between the centres of the femoral head and acetabular cup and the variations in the cup inclination angles on the occurrence and magnitude of the dynamic separation, the severity of edge loading, and the wear rate of ceramic-on-ceramic hip replacement bearings in a multi-station hip joint simulator during a walking gait cycle. An increased mismatch between the centres of rotation of the femoral head and acetabular cup resulted in an increased level of dynamic separation and an increase in the severity of edge loading condition which led to increased wear rate in ceramic-on-ceramic bearings. Additionally for a given translational mismatch, an increase in the cup inclination angle gave rise to increased dynamic separation, worst edge loading conditions, and increased wear. To reduce the occurrence and severity of edge loading, the relative positions (the mismatch) of the centres of rotation of the head and the cup should be considered alongside the rotational position of the acetabular cup. This study has considered the combination of mechanical and tribological factors for the first time in the medial-lateral axis only, involving one rotational angle (inclination) and one translational mismatch. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  10. PRESS FREEDOM IN SINGAPORE AND MALAYSIA: DEFAMATION

    OpenAIRE

    Georgia Kate Chapman

    2015-01-01

    This paper focuses on the arguments around restriction on freedom of the press in the Strong States of Singapore and Malaysia. It assesses the presence of constraints on press freedoms in democratic western countries imposed by corporation rather than state and the similar effects that these constraints may have on bias present in publicly accessible news reporting. It argues that independence of the press does not just require protection from legal and executive regulation, but also protecti...

  11. Brief concept of hip preservation

    Directory of Open Access Journals (Sweden)

    Sanjeev S. Madan

    2017-12-01

    Full Text Available Restoration of the anatomy of the hip joint and biomechanics across it, carry the immense importance to prevent future osteoarthritis of the joint. The aim of this review is to provide the brief concept of the methods to preserve the hip, especially in young adults. Attempts to preserve the hips start with the intense preoperative planning of the corrective procedure. Different parameters regarding the femur and acetabulum in all 3 dimensions need to be assessed. Especially, measurement of the anteversion of the femur and acetabulum is a significant step to avoid osteoarthritis. In addition, the suprapelvic and infrapelvic (spine and lower limb lengths alignment needs to be considered in the planning. Correction of the femoral side of the hip needs the understanding of the blood supply of the proximal femur which carries the risk of avascular necrosis more so with intracapsular osteotomies. Acetabular reorientation, to re-distribute the forces over the weight bearing part, can be carried out with re-directional osteotomy such as periacetabular osteotomy. It needs the understanding of the acetabular anatomy and the force distribution in it. To conclude, correction of both femoral and acetabular side parameters need to be considered in decision making depending on the alterations due to various etiologies causing the hip disorders.

  12. Traumatic hip dislocations in children

    International Nuclear Information System (INIS)

    Minhas, M.S.

    2010-01-01

    Objectives: To evaluate clinical features, treatment and relationship to the time period between dislocation, reduction and early complications of traumatic dislocation of hip in children. Methods: Case series conducted at Jinnah Post Graduate Medical Centre Karachi from July 2005 to August 2009. Children with traumatic hip dislocation up to fifteen years of age who presented in last four years were included in this study. Their clinical information, etiology, associated injuries, duration, method of reduction and early complications are evaluated through emergency room proforma and indoor record. Follow up of patient was updated in outpatient department. Results: We had eight patients, six boys and two girls. Youngest 2.4 years and eldest was 12 years with mean age of 6.2 +- 3.8 years. All presented with posterior hip dislocation. Etiology was road traffic accident in two and history of fall in remaining six patients. Average duration of time between dislocation and reduction was 19 hours range 3-72 hours. Dislocated hips were reduced under General Anaesthesia in two patients and under sedation analgesia in six patients. No complications were noted in eight cases with mean 18.75 +- 13.23 months follows up. Conclusion: Traumatic hip dislocation in children is not rare. Slight trauma causes dislocation in younger age and immediate closed reduction and Immobilization reduces complications. (author

  13. Microplasticity in hot-pressed beryllium

    International Nuclear Information System (INIS)

    Plane, D.C.; Bonfield, W.

    1977-01-01

    Closed hysteresis loops measured in the microstrain region of hot pressed, commercially pure, polycrystalline beryllium are correlated with a dislocation - impurity atom, energy dissipating mechanism. (author)

  14. WordPress 3.7 complete

    CERN Document Server

    Król, Karol

    2013-01-01

    WordPress 3.5 Complete: Third Edition is a comprehensive and step-by-step tutorial packed with screenshots and examples to make it easy and quick to pick it up.This WordPress book is a guide to WordPress for online publishers and web developers. If you are new to blogging and want to create your own blog or website from scratch, then ""WordPress 3.5 Complete: Third Edition"" is for you. No prior knowledge of HTML/CSS or PHP is required.

  15. Activation of Selected Core Muscles during Pressing

    Directory of Open Access Journals (Sweden)

    Thomas W. Nesser

    2015-10-01

    Full Text Available Introduction: Unstable surface training is often used to activate core musculature during resistance training. Unfortunately, unstable surface training is risky and leads to detraining. Purpose: The purpose of this study was to determine core muscle activation during stable surface ground-based lifts. Methods: Fourteen recreational trained and former NCAA DI athletes (weight 84.2 ± 13.3 kg; height 176.0 ± 9.5 cm; age 20.9 ± 2.0 years volunteered for participation. Subjects completed two ground-based lifts: overhead press and push-press. Surface EMG was recorded from 4 muscles on the right side of the body (Rectus Abdominus (RA, External Oblique (EO, Transverse Abdominus (TA, and Erector Spinae (ES. Results: Paired sample T-tests identified significant muscle activation differences between the overhead press and the push-press included ES and EO. Average and peak EMG for ES was significantly greater in push-press (P<0.01. Anterior displacement of COP was significantly greater in push-press compared to overhead press during the eccentric phase. Conclusion: The push-press was identified as superior in core muscle activation when compared to the overhead pressing exercise. Keywords: torso, stability, weight lifting, resistance training

  16. Genetic variances, trends and mode of inheritance for hip and elbow dysplasia in Finnish dog populations

    NARCIS (Netherlands)

    Mäki, K.; Groen, A.F.; Liinamo, A.E.; Ojala, M.

    2002-01-01

    The aims of this study were to assess genetic variances, trends and mode of inheritance for hip and elbow dysplasia in Finnish dog populations. The influence of time-dependent fixed effects in the model when estimating the genetic trends was also studied. Official hip and elbow dysplasia screening

  17. Differential genetic regulation of canine hip dysplasia and osteoarthritis.

    Directory of Open Access Journals (Sweden)

    Zhengkui Zhou

    2010-10-01

    Full Text Available Canine hip dysplasia (HD is a common polygenic trait characterized by hip malformation that results in osteoarthritis (OA. The condition in dogs is very similar to developmental dysplasia of the human hip which also leads to OA.A total of 721 dogs, including both an association and linkage population, were genotyped. The association population included 8 pure breeds (Labrador retriever, Greyhounds, German Shepherd, Newfoundland, Golden retriever, Rottweiler, Border Collie and Bernese Mountain Dog. The linkage population included Labrador retrievers, Greyhounds, and their crosses. Of these, 366 dogs were genotyped at ∼22,000 single nucleotide polymorphism (SNP loci and a targeted screen across 8 chromosomes with ∼3,300 SNPs was performed on 551 dogs (196 dogs were common to both sets. A mixed linear model approach was used to perform an association study on this combined association and linkage population. The study identified 4 susceptibility SNPs associated with HD and 2 SNPs associated with hip OA.The identified SNPs included those near known genes (PTPRD, PARD3B, and COL15A1 reported to be associated with, or expressed in, OA in humans. This suggested that the canine model could provide a unique opportunity to identify genes underlying natural HD and hip OA, which are common and debilitating conditions in both dogs and humans.

  18. Preoperative Education for Hip and Knee Replacement: Never Stop Learning.

    Science.gov (United States)

    Edwards, Paul K; Mears, Simon C; Lowry Barnes, C

    2017-09-01

    Participation in alternative payment models has focused efforts to improve outcomes and patient satisfaction while also lowering cost for elective hip and knee replacement. The purpose of this review is to determine if preoperative education classes for elective hip and knee replacement achieve these goals. Recent literature demonstrates that patients who attend education classes prior to surgery have decreased anxiety, better post-operative pain control, more realistic expectations of surgery, and a better understanding of their surgery. As a result, comprehensive clinical pathways incorporating a preoperative education program for elective hip and knee replacement lead to lower hospital length of stay, higher home discharge, lower readmission, and improved cost. In summary, we report convincing evidence that preoperative education classes are an essential element to successful participation in alternative payment models such as the Bundle Payment Care Initiative.

  19. Developmental hip dysplasia in adolescence

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2009-01-01

    Full Text Available The authors define adolescence and developmental dysplasia of the hip (DDH. Special attention is paid to pathological findings characteristic of DDH in adolescence (unrecognized and untreated DDH; treated DDH, but non-terminated treatment; DDH diagnosed with delay, inadequately treated, with complications. The authors emphasise that DDH treatment has to be successfully terminated well before the adolescence; possibilities are explained on management modes at the time of adolescence, and possible persons guilty for the persistence of later hip problems are indicated. Based on the authors' experience and having in mind all surgical possibilities for the treatment (pelvic osteotomies, femoral osteotomies, trochanteroplasties, leg length equalization procedures the authors propose treatment protocols. The intention is to provide better treatment results and to prevent secondary hip arthrosis. Furthermore, how to improve the struggle against DDH is suggested.

  20. MRI of the hip joint

    International Nuclear Information System (INIS)

    Czerny, C.; Noebauer-Huhmann, I.M.; Imhof, H.

    2005-01-01

    Magnetic resonance imaging (MRI) is performed to diagnose many pathologic conditions affecting the hip joint. Either conventional MRI (without contrast enhancement of the joint cavity) or MR arthrography is used to detect and most accurately differentiate hip joint pathologies. Conventional MRI is performed in cases of bone marrow edema, necrosis, arthrosis and especially the so-called ''activated arthrosis'', as well as in inflammatory and tumorous entities. MR arthography, which has only recently become available for use, is excellently suited for diagnosing lesions of the acetabular labrum, cartilage lesions, and free articular bodies. This article provides an overview about MRI characteristics and their accuracy of hip joint diseases and the impact on the therapeutic procedure. (orig.)

  1. Processing and properties of calcium phosphates bioceramics by hot isostatic pressing

    Directory of Open Access Journals (Sweden)

    Boilet Laurent

    2013-11-01

    Full Text Available Stoichiometric β-tricalcium phosphate (β-TCP, hydroxyapatite (HA and biphasic calcium phosphate (TCP/HA 60/40 %wt, BCP40 powders were synthesized by chemical precipitation of aqueous solutions of diammonium phosphate and calcium nitrate. After a calcination treatment and a milling step, powders were shaped by slip-casting. The sintering temperature effect on the density and the average grain size was investigated. By natural sintering, densities between 98 and 99.8% were obtained. Hot Isostatic Pressing (HIP treatment was carried out after a pre-sintering of these materials. Transparent or translucent samples were obtained, indicating a relative density very close to the theoretical value (>99.9%. Mechanical properties (three-point bending strength, fracture toughness, Young's modulus and Vickers hardness were measured on hipped materials with similar grain size (∼0.7μm.

  2. Characterization of 316L(N)-IG SS joint produced by hot isostatic pressing technique

    International Nuclear Information System (INIS)

    Nakano, J.; Miwa, Y.; Tsukada, T.; Kikuchi, M.; Kita, S.; Nemoto, Y.; Tsuji, H.; Jitsukawa, S.

    2002-01-01

    Type 316L(N) stainless steel of the international thermonuclear experimental reactor grade (316L(N)-IG SS) is being considered for the first wall/blanket module. Hot isostatic pressing (HIP) technique is expected for the fabrication of the module. To evaluate the integrity and susceptibility to stress corrosion cracking (SCC) of HIPed 316L(N)-IG SS, tensile tests in vacuum and slow strain rate tests in high temperature water were performed. Specimen with the HIPed joint had similar tensile properties to specimens of 316L(N)-IG SS, and did not show susceptibility to SCC in oxygenated water at 423 K. Thermally sensitized specimen was low susceptible to SCC even in the creviced condition. It is concluded that the tensile properties of HIPed SS are as high as those of the base alloy and the HIP process caused no deleterious effects

  3. Risks of hip and knee replacement

    Science.gov (United States)

    ... is normal to lose blood during and after hip or knee replacement surgery. Some people need a ... clot form are higher during and soon after hip or knee replacement surgery. Sitting or lying down ...

  4. Forming and control of pores by capsule-free hot isostatic pressing in NiTi shape memory alloys

    International Nuclear Information System (INIS)

    Yuan, B; Zhu, M; Gao, Y; Li, X; Chung, C Y

    2008-01-01

    In this study, the pore evolution process of porous NiTi shape memory alloys (SMAs) fabricated by capsule-free hot isostatic pressing (CF-HIP) was investigated by adopting different fabricating parameters. It is shown that porous NiTi SMAs with homogeneous pore distribution and nearly spherical pore shape can be prepared by CF-HIP under suitable conditions. In addition, two novel pore structures were produced, one with a sandwich-like structure, and another with controlled gradient of porosity along the radial direction, with pore size increasing from the outside towards the center of the specimen. The former was obtained by balancing the pressure in the HIP chamber and the gas pressure resulting from the gas expansion in the green sample. The latter resulted from the formation of air bubbles in the liquid phase during the sintering

  5. Exercise therapy may postpone total hip replacement surgery in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Svege, Ida; Nordsletten, Lars; Fernandes, Linda

    2015-01-01

    Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown.......Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown....

  6. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty. Precision biased by region of interest and rotation of the hip

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

      Introduction:  Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type of ROI...... the hip was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without...

  7. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty....... Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  8. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  9. Agreement and Reliability of Functional Performance and Muscle Power in Patients with Advanced Osteoarthritis of the Hip or Knee

    DEFF Research Database (Denmark)

    Villadsen, Allan; Roos, Ewa M; Overgaard, Søren

    2012-01-01

    -time repeated chair stands, and repeated unilateral knee bending). RESULTS: For single-joint and multijoint maximal peak power and functional performance measures, we demonstrated poor (CVws, approximately 25%, single-joint hip extension) and moderate (CVws, approximately 15%, multijoint leg extension press......OBJECTIVE: The purpose of this study was to test the reproducibility and clinical feasibility of three functional performance measures and five single-joint or multijoint muscle power measures. DESIGN: Twenty patients with a mean age of 68.7 ± 7.2 yrs with severe hip or knee osteoarthritis were...... assessed for test-retest reliability and agreement on two occasions 1 wk apart. The outcomes were maximal single-joint muscle power (hip extension/abduction and knee extension/flexion), maximal muscle power during multijoint leg extension press, and functional performance measures (20-m walk, five...

  10. Teenagers as Victims in the Press

    Science.gov (United States)

    Andersson, Gunvor; Lundstrom, Tommy

    2007-01-01

    Research into press reporting on young people has tended to concentrate on young people as offenders. In contrast, this article focuses on press coverage of teenagers as victims. Reports in two Swedish newspapers (a morning broadsheet and an evening tabloid) were studied over a period of four months and subjected to a qualitative analysis of…

  11. Communicators take nine Virginia Press Women awards

    OpenAIRE

    Owczarski, Mark

    2008-01-01

    Three Virginia Tech communicators have won Virginia Press Women awards. The winners - Susan Trulove, research division communications manager; Clara Cox, university publications director; and Heather Riley Chadwick, College of Architecture and Urban Studies communication manager - were announced at the Virginia Press Women Annual Spring Conference in Staunton, Va.

  12. 1979: The Campus Student Press in America.

    Science.gov (United States)

    Ingelhart, Louis E.

    1979-01-01

    Discusses a number of topics involving the campus press, including the independence of campus publications, censorship issues, the relationship between the student press and the college administrator, the financing of student newspapers, yearbook production and financing, probable future student publications trends, and the need for appropriate…

  13. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    Science.gov (United States)

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal

  14. Treatment of tuberculosis of the hip.

    African Journals Online (AJOL)

    The common presentation was a swollen hip, a limp, decreased range of hip movements, fixed flexion deformity and pain. Three patients had protrusio acetabuli and three had subluxed or dislocated hips. Twenty-three patients were anaemic and the erythrocyte sedimentation rate (ESR) was raised in all (mean. 6 5 d h r ...

  15. Hip-Hop and the Academic Canon

    Science.gov (United States)

    Abe, Daudi

    2009-01-01

    Over the last 30 years, the hip-hop movement has risen from the margins to become the preeminent force in US popular culture. In more recent times academics have begun to harness the power of hip-hop culture and use it as a means of infusing transformative knowledge into the mainstream academic discourse. On many college campuses, hip-hop's…

  16. Ultrasonography of the painful hip in childhood

    NARCIS (Netherlands)

    S.G.F. Robben (Simon)

    1999-01-01

    textabstractThere are many diseases in childhood that affect the hip joint. Some diseases are systemic in origin and initially may present themselves as hip disorders, such as rheumatoid arthritis. other diseases are localized specifically in the hip joint, such as transient synovitis and Perthes'

  17. Development of ITER shielding blanket prototype mockup by HIP bonding

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Satoshi; Furuya, Kazuyuki; Hatano, Toshihisa; Kuroda, Toshimasa; Enoeda, Mikio; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Takatsu, Hideyuki [Japan Atomic Energy Research Inst., Office of ITER Project Promotion, Tokyo (Japan)

    2000-07-01

    A prototype ({approx}900{sup H} x 1700{sup W} x 350{sup T} mm) of the ITER shielding blanket module has been fabricated following the previous successful fabrication of a small-scale ({approx}500{sup H} x 400{sup W} x 150{sup T} mm) and mid-scale ({approx}800{sup H} x 500{sup W} x 350{sup T} mm) mock-ups. This prototype incorporates most of key design features essential to the fabrication of the ITER shielding blanket module such as 1) the first wall heat sink made of Al{sub 2}O{sub 3} dispersion strengthened Cu (DSCu) with built-in SS316L coolant tubes bonded to a massive SS316LN shield block, 2) toroidally curved first wall with a radius of 5106 mm while straight in poloidal direction, 3) coolant channels oriented in poloidal direction in the first wall and in toroidal direction in the shield block, 4) the first wall coolant channel routing to avoid the interference with the front access holes, 5) coolant channels drilled through the forged SS316LN-IG shield block, and 6) four front access holes of 30 mm in diameter penetrated through the first wall and the shield block. For the joining method, especially for the first wall/side wall parts and the shield block, the solid HIP (Hot Isostatic Pressing) process was applied. It is difficult to apply conventional joining methods such as field welding, brazing, explosion bonding and mechanical one-axial diffusion bonding to a wide area bonding because sufficient mechanical strengths can not be obtained and excessive deformations occurs. In order to solve these fabrication issues, HIP bonding was applied. The first wall stainless steel (SS) coolant tubes of 10 mm in inner diameter and l mm in thickness were sandwiched by semi-circular grooved DSCu plates at the first wall and the front region of the side wall, and by semi-circular grooved SS plates at the back region of the side wall. After assembling of these first wall/side wall parts with the shield block, they were simultaneously bonded by single step HIP in order to

  18. Introducing Collabra, OA Journal from University of California Press

    OpenAIRE

    Morgan, Daniel

    2015-01-01

    An introductory presentation of Collabra, the open access mega journal from University of California Press, highlighting its unique business model which shares and spreads revenue back to the research community. (Presented at the FORCE 2015 conference at the University of Oxford, January 13, 2015.)

  19. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  20. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  1. Encapsulation of Protein-Polysaccharide HIP Complex in Polymeric Nanoparticles

    Directory of Open Access Journals (Sweden)

    Ripal Gaudana

    2011-01-01

    Full Text Available The objective of the present study is to formulate and characterize a nanoparticulate-based formulation of a macromolecule in a hydrophobic ion pairing (HIP complex form. So far, HIP complexation approach has been studied only for proteins with molecular weight of 10–20 kDa. Hence, we have selected bovine serum albumin (BSA having higher molecular weight (66.3 kDa as a model protein and dextran sulphate (DS as a complexing polymer to generate HIP complex. We have prepared and optimized the HIP complex formation process of BSA with DS. Ionic interactions between basic amino acids of BSA with sulphate groups of DS were confirmed by FTIR analysis. Further, nanoparticles were prepared and characterized with respect to size and surface morphology. We observed significant entrapment of BSA in nanoparticles prepared with minimal amounts of PLGA polymer. Finally, results of circular dichroism and intrinsic fluorescence assay have clearly indicated that HIP complexation and method of nanoparticle preparation did not alter the secondary and tertiary structures of BSA.

  2. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  3. Influence of Powder Surface Contamination in the Ni-Based Superalloy Alloy718 Fabricated by Selective Laser Melting and Hot Isostatic Pressing

    Directory of Open Access Journals (Sweden)

    Yen-Ling Kuo

    2017-09-01

    Full Text Available The aim of this study was to gain a deep understanding of the microstructure-mechanical relationship between solid-state sintering and full-melting processes. The IN718 superalloy was fabricated by hot isostatic pressing (HIP and selective laser melting (SLM. Continuous precipitates were clearly localized along the prior particle boundary (PPB in the HIP materials, while SLM materials showed a microstructure free of PPB. The mechanical properties of specimens that underwent SLM + solution treatment and aging were comparable to those of conventional wrought specimens both at room temperature and 650 °C. However, a drop was observed in the ductility of HIP material at 650 °C. The brittle particles along the PPB were found to affect the HIP materials’ creep life and ductility during solid-state sintering.

  4. Hip-Hop Pop Art

    Science.gov (United States)

    Talley, Clarence, Sr.

    2011-01-01

    Art has a way of helping students better understand and appreciate the world around them, particularly the things that are most important to them. Hip hop is one of those generational genres that capture the attention of young students like few other things do. Drawing on this genre to get students to create art is an excellent way to demonstrate…

  5. Improving hip surgery patients’ outcomes:

    DEFF Research Database (Denmark)

    Bagger, Bettan; Poulsen, Dorthe Varning; Taylor Kelly, Hélène

    This presentation focuses upon the improvement of hip surgery patients’ outcomes with respect to health promotion and rehabilitation. The overall aims of the EU financed orthopedic nursing project will be introduced. Speakers highlight the project’s contribution to: -the development of nurse...

  6. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  7. Simplex network modeling for press-molded ceramic bodies incorporated with granite waste; Dosagem de massa ceramica para blocos prensados com adicao de residuo de granito atraves do metodo simplex

    Energy Technology Data Exchange (ETDEWEB)

    Pedroti, L.G.; Vieira, C.M.F.; Alexandre, J.; Monteiro, S.N.; Xavier, G.C., E-mail: lpedroti@gmail.com [Universidade Estadual do Norte Fluminense Darcy Ribeiro (UENF), Campos dos Goytacazes, RJ (Brazil)

    2012-07-01

    Extrusion of a clay body is the most commonly applied process in the ceramic industries for manufacturing structural block. Nowadays, the assembly of such blocks through a fitting system that facilitates the final mounting is gaining attention owing to the saving in material and reducing in the cost of the building construction. In this work, the ideal composition of clay bodies incorporated with granite powder waste was investigated for the production of press-molded ceramic blocks. An experimental design was applied to determine the optimum properties and microstructures involving not only the precursors compositions but also the press and temperature conditions. Press load from 15 ton and temperatures from 850 to 1050°C were considered. The results indicated that varying mechanical strength of 2 MPa to 20 MPa and varying water absorption of 19% to 30%. (author)

  8. Effect of Temperature on the Fracture Toughness of Hot Isostatically Pressed 304L Stainless Steel

    OpenAIRE

    Cooper, Adam J.; Sherry, Andrew

    2018-01-01

    Herein, we have performed J-Resistance multi-specimen fracture toughness testing of hot isostatically pressed (HIP’d) and forged 304L austenitic stainless steel, tested at elevated (300 °C) and cryogenic (− 140 °C) temperatures. The work highlights that although both materials fail in a pure ductile fashion, stainless steel manufactured by HIP displays a marked reduction in fracture toughness, defined using J0.2BL, when compared to equivalently graded forged 304L, which is relatively constant...

  9. Preliminary Study on Hot Isostatic Pressing Diffusion Bonding for CLAM Steel

    International Nuclear Information System (INIS)

    Chunjing Li; Qunying Huang; Yican Wu

    2006-01-01

    China Low Activation Martensitic (CLAM) steel is being developed in ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences) since three years ago. CLAM is selected as the major candidate structure materials for the FDS series design of fusion reactors and for China liquid metal LiPb Test Blanket Module (TBM) for ITER i.e. DFLL-TBM, which are being carried out in ASIPP. Since the hot isostatic pressing (HIP) bonding technique is one of the main candidate bonding techniques for manufacturing of the first wall of a fusion reactor, research of the HIP technique on CLAM/CLAM is greatly needed. Preliminary HIP diffusion bonding experiments on CLAM steel have been performed. A few machining approaches such as dry-milling, turnery and grounding etc. were used to prepare the sample surfaces and then they were degreased with a mixture of alcohol, ether and acetone in an ultrasonic bath. The samples were joined by HIP diffusion bonding with the compression pressure of 150 MPa and the holding time of 2 ∼ 3 hours under different temperatures between 950 deg. and 1100 deg.. Different seal techniques of the capsules were studied as well. Then appropriate post heat treatment was done. Tests on mechanical properties of the joints such as tensile strength and impact toughness have been performed. The preliminary results show that the tensile properties are roughly the same as those of the base material. The absorbed energy of the joints at present is a little low and further research is needed to increase it. Microstructure of the joints was studied by optical microscope, SEM and TEM. Compositions of the defects on the joining line were analyzed by EDS. Through analysis of the results, optimized parameters for HIP are given. (author)

  10. Determinants of staff commitment to hip protectors in long-term care: A cross-sectional survey.

    Science.gov (United States)

    Korall, Alexandra M B; Loughin, Thomas M; Feldman, Fabio; Cameron, Ian D; Leung, Pet Ming; Sims-Gould, Joanie; Godin, Judith; Robinovitch, Stephen N

    2018-06-01

    If worn, certain models of hip protectors are highly effective at preventing hip fractures from falls in residents of long-term care, but modest acceptance and adherence have limited the effectiveness of hip protectors. Residents of long-term care are more likely to accept the initial offer of hip protectors and to adhere to recommendations concerning the use of hip protectors when staff are committed to supporting the application of hip protectors. Yet, we know very little about the nature of and factors associated with staff commitment to hip protectors in long-term care. To identify factors associated with staff commitment to hip protectors in long-term care. A cross-sectional survey. Thirteen long-term care homes (total beds = 1816) from a single regional health district in British Columbia, Canada. A convenience sample of 535 paid staff who worked most of their time (>50% of work hours) at a participating long-term care home, for at least one month, and for at least 8 h per week. We excluded six (1.1%) respondents who were unaware of hip protectors. Of the remaining 529 respondents, 90% were female and 55% were health care assistants. Respondents completed the Commitment to Hip Protectors Index to indicate their commitment to hip protectors. We used Bayesian Model Averaging logistic regression to model staff commitment as a function of personal variables, experiences with hip protectors, intraorganizational communication and influence, and organizational context. Staff commitment was negatively related to organizational tenure >20 years (posterior probability = 97%; logistic regression coefficient = -0.28; 95% confidence interval = -0.48, -0.08), and awareness of a padded hip fracture (100%; -0.57; -0.69, -0.44). Staff commitment was positively related to the existence of a champion of hip protectors within the home (100%; 0.24; 0.17, 0.31), perceived quality of intraorganizational communication (100%; 0.04; 0.02, 0.05), extent of mutual

  11. Is the association between hip fractures and seasonality modified by influenza vaccination? An ecological study.

    Science.gov (United States)

    Fraenkel, M; Yitshak-Sade, M; Beacher, L; Carmeli, M; Mandelboim, M; Siris, E; Novack, V

    2017-09-01

    Osteoporotic hip fractures in 4344 patients were more common during winter. Lower temperatures were associated with higher rates of fracture only in those not vaccinated for influenza. Influenza outbreaks increased the risk of hip fractures. Further studies are needed to assess whether influenza vaccination can prevent hip fractures. Winter seasonality of osteoporotic hip fracture incidence has been demonstrated, yet the explanation for the association is lacking. We hypothesize that the seasonality of osteoporotic hip fracture can be explained by an association between hip fractures and seasonal influenza outbreaks. This retrospective cohort study included all patients admitted to Soroka University Medical Center with a diagnosis of osteoporotic hip fracture (ICD-9 code 820) between the years 2001 and 2013. Patients with malignancies, trauma, and age under 50 were excluded. In a time series analysis, we examined the association between hip fracture incidence and seasonality adjusted for meteorological factors, and population rates of influenza infection and vaccination using Poisson models. Four thousand three hundred forty-four patients with a hip fracture were included (69% females, mean age 78). Daily fracture rates were significantly higher in winter (1.1 fractures/day) compared to summer, fall, and spring (0.79, 0.90, and 0.91; p risk only in those not vaccinated for influenza (n = 2939, for every decrease of 5 °C, RR 1.08, CI 1.02-1.16; p risk for hip fracture, adjusted for seasons and temperature, was 1.26 2 weeks following a week with high infection burden (CI 1.05;1.51 p = 0.01), while the temperature was not significantly associated with the fracture risk. Under dry and warm desert climate, winter hip fracture incidence increase might be associated with influenza infection, and this effect can be negated by influenza vaccination.

  12. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  13. Recurrent Hip Fracture Prevention With Osteoporosis Management

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2007-02-01

    Full Text Available Background:Osteoporosis is a major public health threat,and hip fracture is a serious consequence of osteoporosis.Apatient with an osteoporosis-related hip fracture has an increased risk for a second hip fracture.The effect of osteoporosis management on the risk of recurrent hip fracture was evaluated in this study.Methods:58 hip fracture patients older than 50yr and BMD < 2.5 were discharged from hospital with Ca-Vitamin D- Alendronate prescriptions, and followed up for 4 years to determine the rate of recurrent hip fractures. Rate of second hip fractures was compared with 58 hip fractures in the control group (without osteoporosis treatment which were also followed for 4 years. Results:72% of patients continued treatment for 2 years. There were no second hip fractures in the critical first 12 months in the treated group.Overall second hip fractures in osteoporosis treated and control groups were 3.4% and 8.6%(p<0.03, respectively.Conclusion:Management of hip fractures in the elderly should include bone mineral density determination and osteoporosis treatment to prevent further fractures.

  14. WordPress web design for dummies

    CERN Document Server

    Sabin-Wilson, Lisa

    2013-01-01

    Updated, full-color guide to creating dynamic websites with WordPress 3.6 In this updated new edition, bestselling For Dummies author and WordPress expert Lisa Sabin-Wilson makes it easy for anyone with a basic knowledge of the WordPress software to create a custom site using complementary technologies such as CSS, HTML, PHP, and MySQL. You'll not only get up to speed on essential tools and technologies and further advance your own design skills, this book also gives you pages of great case studies, so you can see just how other companies and individuals are creating compelling, customized, a

  15. Teach yourself visually complete WordPress

    CERN Document Server

    Majure, Janet

    2013-01-01

    Take your WordPress skills to the next level with these tips, tricks, and tasks Congratulations on getting your blog up and running with WordPress! Now are you ready to take it to the next level? Teach Yourself VISUALLY Complete WordPress takes you beyond the blogging basics with expanded tips, tricks, and techniques with clear, step-by-step instructions accompanied by screen shots. This visual book shows you how to incorporate forums, use RSS, obtain and review analytics, work with tools like Google AdSense, and much more.Shows you how to use mobile tools to edit a

  16. WordPress 24-Hour Trainer

    CERN Document Server

    Plumley, George

    2011-01-01

    The eagerly anticipated second edition, completely updated for WordPress 3.1 As an open source content management system, WordPress allows users to easily build feature-rich web sites with no programming experience. This unique book-and-video package is a friendly, self-paced beginners guide to the latest release of WordPress. Lessons are focused on practical, everyday tasks that users will need to create and maintain their sites: entering new content, creating new pages, managing menus, making content search-engine friendly. Plus you'll find lots of tips based on years of experience teaching

  17. WordPress web application development

    CERN Document Server

    Ratnayake, Rakhitha Nimesh

    2013-01-01

    An extensive, practical guide that explains how to adapt WordPress features, both conventional and trending, for web applications.This book is intended for WordPress developers and designers who have the desire to go beyond conventional website development to develop quality web applications within a limited time frame and for maximum profit. Experienced web developers who are looking for a framework for rapid application development will also find this to be a useful resource. Prior knowledge with of WordPress is preferable as the main focus will be on explaining methods for adapting WordPres

  18. Professional WordPress Plugin Development

    CERN Document Server

    Williams, Brad; Tadlock, Justin

    2011-01-01

    Taking WordPress to the next level with advanced plugin developmentWordPress is used to create self-hosted blogs and sites, and it's fast becoming the most popular content management system (CMS) on the Web. Now you can extend it for personal, corporate and enterprise use with advanced plugins and this professional development guide. Learn how to create plugins using the WordPress plugin API: utilize hooks, store custom settings, craft translation files, secure your plugins, set custom user roles, integrate widgets, work with JavaScript and AJAX, create custom post types. You'll find a practic

  19. Enhancement in the microstructure and neutron shielding efficiency of sandwich type of 6061Al–B4C composite material via hot isostatic pressing

    International Nuclear Information System (INIS)

    Park, Jin-Ju; Hong, Sung-Mo; Lee, Min-Ku; Rhee, Chang-Kyu; Rhee, Won-Hyuk

    2015-01-01

    Highlights: • 6061Al–B 4 C neutron shielding composites are fabricated by sintering and HIP. • HIP process improves the wettability of B 4 C particles into 6061Al matrix. • Neutron attenuation performance can be enhanced by application of HIP process. - Abstract: Sandwich type of 6061Al–B 4 C composite plates, which are used as a thermal neutron absorber for spent nuclear fuel pool storage rack, were fabricated using two different consolidation ways as sintering and hot isostatic pressing (HIP) processes and their thermal neutron shielding efficiency was investigated as a function of B 4 C concentration ranging from 0 to 40 wt.%. For this purpose, two respective inner core compaction parts of sintered and HIPped neutron absorbing composite materials were first produced and then cladded them between two outer plates by HIP process. The application of HIP process provided not only a lead of excellent interfacial adhesion due to the improved wettability but also an enhancement of thermal neutron shielding efficiency owing to the more uniform dispersion of B 4 C particles

  20. The influence of renal dialysis and hip fracture sites on the 10-year mortality of elderly hip fracture patients

    Science.gov (United States)

    Hung, Li-Wei; Hwang, Yi-Ting; Huang, Guey-Shiun; Liang, Cheng-Chih; Lin, Jinn

    2017-01-01

    Abstract Hip fractures in older people requiring dialysis are associated with high mortality. Our study primarily aimed to evaluate the specific burden of dialysis on the mortality rate following hip fracture. The secondary aim was to clarify the effect of the fracture site on mortality. A retrospective cohort study was conducted using Taiwan's National Health Insurance Research Database to analyze nationwide health data regarding dialysis and non-dialysis patients ≥65 years who sustained a first fragility-related hip fracture during the period from 2001 to 2005. Each dialysis hip fracture patient was age- and sex-matched to 5 non-dialysis hip fracture patients to construct the matched cohort. Survival status of patients was followed-up until death or the end of 2011. Survival analyses using multivariate Cox proportional hazards models and the Kaplan-Meier estimator were performed to compare between-group survival and impact of hip fracture sites on mortality. A total of 61,346 hip fracture patients were included nationwide. Among them, 997 dialysis hip fracture patients were identified and matched to 4985 non-dialysis hip fracture patients. Mortality events were 155, 188, 464, and 103 in the dialysis group, and 314, 382, 1505, and 284 in the non-dialysis group, with adjusted hazard ratios (associated 95% confidence intervals) of 2.58 (2.13–3.13), 2.95 (2.48–3.51), 2.84 (2.55–3.15), and 2.39 (1.94–2.93) at 0 to 3 months, 3 months to 1 year, 1 to 6 years, and 6 to 10 years after the fracture, respectively. In the non-dialysis group, survival was consistently better for patients who sustained femoral neck fractures compared to trochanteric fractures (0–10 years’ log-rank test, P fractures was better than that of patients with trochanteric fractures only within the first 6 years post-fracture (0–6 years’ log-rank, P fracture patients. Survival outcome was better for non-dialysis patients with femoral neck fractures compared to those with

  1. Femoral head fracture without hip dislocation

    Directory of Open Access Journals (Sweden)

    Aggarwal Aditya K

    2013-10-01

    Full Text Available 【Abstract】Femoral head fractures without dislocation or subluxation are extremely rare injuries. We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high en- ergy trauma due to road traffic accident. He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39. He received cementless total hip replacement. At latest follow-up of 2.3 years, functional outcome was excellent with Harris hip score of 95. Such isolated injuries have been described only once in the literature and have not been classified till now. The purpose of this report is to highlight the extreme rarity, possible mechanism involved and a novel classification system to classify such injuries. Key words: Femur head; Hip dislocation; Classification; Arthroplasty, replacement, hip

  2. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  3. Evolution of the hip and pelvis.

    Science.gov (United States)

    Hogervorst, Tom; Bouma, Heinse W; de Vos, John

    2009-08-01

    Man's evolution features two unique developments: growing a huge brain and upright gait. Their combination makes the pelvis the most defining skeletal element to read human evolution. Recent revival in joint preserving hip surgery have brought to attention morphological variations of the human hip that appear similar to hips of extant mammals. In man, such variations can produce hip osteoarthrosis through motion. We reviewed the evolution of the hip and pelvis with special interest in morphology that can lead to motion induced osteoarthrosis in man. The combination of giving birth to big brained babies and walking upright has produced marked differences between the sexes in pelvis and hip morphology, each having their characteristic mode of hip impingement and osteoarthrosis.

  4. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  5. Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention

    DEFF Research Database (Denmark)

    Lauritzen, J B

    1997-01-01

    have a high risk of hip fracture (annual rate of 5-6%), and the incidence of falls is about 1,500 falls/1,000 persons/year. Most hip fractures are a result of a direct trauma against the hip. The incidence of falls on the hip among nursing home residents is about 290 falls/1,000 persons/year and about......%, corresponding to 9 out of 247 residents saved from sustaining a hip fracture. The review points to the essentials of the development of hip fracture, which constitutes; risk of fall, type of fall, type of impact, energy absorption, and lastly bone strength, which is the ultimate and last permissive factor......The present review summarizes the pathogenic mechanisms leading to hip fracture based on epidemiological, experimental, and controlled studies. The estimated lifetime risk of hip fracture is about 14% in postmenopausal women and 6% in men. The incidence of hip fractures increases exponentially...

  6. Factors that influence exercise activity among women post hip fracture participating in the Exercise Plus Program

    OpenAIRE

    Resnick, Barbara; Orwig, Denise; D?Adamo, Christopher; Yu-Yahiro, Janet; Hawkes, William; Shardell, Michelle; Golden, Justine; Zimmerman, Sheryl; Magaziner, Jay

    2007-01-01

    Using a social ecological model, this paper describes selected intra- and interpersonal factors that influence exercise behavior in women post hip fracture who participated in the Exercise Plus Program. Model testing of factors that influence exercise behavior at 2, 6 and 12 months post hip fracture was done. The full model hypothesized that demographic variables; cognitive, affective, physical and functional status; pain; fear of falling; social support for exercise, and exposure to the Exer...

  7. Study of Servo Press with a Flywheel

    Science.gov (United States)

    Tso, Pei-Lum; Li, Cheng-Ho

    The servo press with a flywheel is able to provide flexible motions with energy-saving merit, but its true potential has not been thoroughly studied and verified. In this paper, such the “hybrid-driven” servo press is focused on, and the stamping capacity and the energy distribution between the flywheel and the servomotor are investigated. The capacity is derived based on the principle of energy conservation, and a method of using a capacity percentage plane for evaluation is proposed. A case study is included to illustrate and interpret that the stamping capacity is highly dependent on the programmed punch motions, thus the capacity prediction is always necessary while applying this kind of servo press. The energy distribution is validated by blanking experiments, and the results indicate that the servomotor needs only to provide 15% to the flywheel torque, 12% of the total stamping energy. This validates that the servomotor power is significantly saved in comparison with conventional servo presses.

  8. Nanoindentation hardness of hot-pressed boron suboxide

    International Nuclear Information System (INIS)

    Machaka, Ronald; Derry, Trevor E.; Sigalas, Iakovos

    2011-01-01

    Highlights: → The load-displacement indentation response of hot-pressed B 6 O is measured and analysed. → The nanoindentation hardness of hot-pressed boron suboxide is reported. → An approach is developed to simulate multi-cycling loading load-displacement curves. → A comprehensive model inter-comparison study of the ISE in hot-pressed B 6 O is also presented. → The fractal dimension is a better measure of ISE than the Meyer's index. - Abstract: The existence of the indentation size effect implies the absence of a single hardness value for the material under investigation especially at low applied loads. In this paper we present an investigation of the indentation size dependence behaviour of nanoindentation hardness in boron suboxide ceramic compacts prepared by uniaxial hot-pressing. Berkovich nanohardness indentations were conducted and analyzed accordingly. In addition to the ordinary Oliver and Pharr method of nanoindentation data analysis, a quantitative approach for the loading curve analysis is proposed. Using the proposed approach, the description and characterization of the observed indentation size effect through the application of the Meyer's law, and the classical and the modified proportional specimen resistance models as well as the multi-fractal scaling law was conducted and is reported. The load-independent hardness values deduced from our quantitative approach are comparable to the results calculated with conventional methods, especially with the multi-fractal scaling law.

  9. Nanoindentation hardness of hot-pressed boron suboxide

    Energy Technology Data Exchange (ETDEWEB)

    Machaka, Ronald, E-mail: Ronald.Machaka@wits.ac.za [DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P. Bag 3, Wits, Johannesburg (South Africa); School of Chemical and Metallurgical Engineering, University of the Witwatersrand, P.O. Bag 3, Wits, Johannesburg 2050 (South Africa); Derry, Trevor E. [DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P. Bag 3, Wits, Johannesburg (South Africa); School of Physics, University of the Witwatersrand, P.O. Bag 3, Wits, Johannesburg 2050 (South Africa); Sigalas, Iakovos [DST/NRF Centre of Excellence in Strong Materials, University of the Witwatersrand, P. Bag 3, Wits, Johannesburg (South Africa); School of Chemical and Metallurgical Engineering, University of the Witwatersrand, P.O. Bag 3, Wits, Johannesburg 2050 (South Africa)

    2011-07-15

    Highlights: {yields} The load-displacement indentation response of hot-pressed B{sub 6}O is measured and analysed. {yields} The nanoindentation hardness of hot-pressed boron suboxide is reported. {yields} An approach is developed to simulate multi-cycling loading load-displacement curves. {yields} A comprehensive model inter-comparison study of the ISE in hot-pressed B{sub 6}O is also presented. {yields} The fractal dimension is a better measure of ISE than the Meyer's index. - Abstract: The existence of the indentation size effect implies the absence of a single hardness value for the material under investigation especially at low applied loads. In this paper we present an investigation of the indentation size dependence behaviour of nanoindentation hardness in boron suboxide ceramic compacts prepared by uniaxial hot-pressing. Berkovich nanohardness indentations were conducted and analyzed accordingly. In addition to the ordinary Oliver and Pharr method of nanoindentation data analysis, a quantitative approach for the loading curve analysis is proposed. Using the proposed approach, the description and characterization of the observed indentation size effect through the application of the Meyer's law, and the classical and the modified proportional specimen resistance models as well as the multi-fractal scaling law was conducted and is reported. The load-independent hardness values deduced from our quantitative approach are comparable to the results calculated with conventional methods, especially with the multi-fractal scaling law.

  10. WordPress 3 For Business Bloggers

    CERN Document Server

    Thewlis, Paul

    2011-01-01

    This is a practical, hands-on book based around a fictitious case study blog, which you will build on a development server using WordPress. The case study grows chapter by chapter, from installing your local development server, right up to the finished blog. This book is for anybody running or starting a business blog using WordPress, whether you plan to use your blog for PR and marketing, or want to profit directly from blogging.

  11. Denmark, Democracy and the Free Press

    DEFF Research Database (Denmark)

    Breiting, Søren

    2006-01-01

    What's important to Danish people in Denmark and in the world - most will argue for the importance of a free critical press, solidarity with people who need help and a peaceful world.......What's important to Danish people in Denmark and in the world - most will argue for the importance of a free critical press, solidarity with people who need help and a peaceful world....

  12. The Liberal Struggle for Press Freedom

    DEFF Research Database (Denmark)

    Mogensen, Kirsten

    In this paper, the public debate following the re-ligion-motivated assassination of Dutch filmmaker Theo van Gogh in November 2004 is examined. The paper aims at describ-ing religious as well as secular positions in the Danish debate about freedom of speech and press in relation to religious issues....... Historically, the concept of press freedom was linked to a fight for religious freedom in London, as described by Siebert....

  13. Hip dysplasia: a significant risk factor for the development of hip osteoarthritis. A cross-sectional survey

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    joint space width (JSW) /=60 yr of age. Of factors entered into logistic regression analyses, only age (P LT 0.001 for right hips and P LT 0.001 for left hips) and hip dysplasia (P LT 0.001 for right hips and P = 0.004 for left hips) were significantly associated with hip OA prevalence in women. In men......, only hip dysplasia was associated with hip OA prevalence, P LT 0.001 in right hips and P = 0.001 in left hips. CONCLUSIONS: Of the individual risk factors investigated in this study, only age and hip dysplasia were associated with the development of hip osteoarthritis.......OBJECTIVES: The aim of this cross-sectional survey of 2232 women and 1336 men (age range 20-91 yr) was to investigate individual risk factors for hip joint osteoarthritis (OA). METHODS: Standardized, weight-bearing pelvic radiographs were evaluated. Radiological hip joint OA was defined as minimum...

  14. Use of Awamori-pressed Lees and Tofu Lees as Feed Ingredients for Growing Female Goats

    Directory of Open Access Journals (Sweden)

    Itsuki Nagamine

    2012-12-01

    Full Text Available Okinawan Awamori is produced by fermenting steamed indica rice with black mold, yeast, and water. Awamori-pressed lees is a by-product of the Awamori production process. Tofu lees is a by-product of the Tofu production process. This research consisted of two experiments conducted to elucidate whether or not dried Awamori-pressed lees and Tofu lees can be used as a mixed feed ingredient for raising female goats. In experiment 1, digestion trials were conducted to ascertain the nutritive values of dried Awamori-pressed lees and dried Tofu lees for goats. The digestible crude protein (DCP and total digestible nutrients (TDN contents of dried Awamori-pressed lees and Tofu lees were 22.5%, 22.5% (DCP, and 87.2%, 94.4% (TDN respectively. In experiment 2, 18 female goats (Japanese Saanen×Nubian, three months old, body weight 15.4±0.53 kg were divided into three groups of six animals (control feed group (CFG, Awamori-pressed lees mixed feed group (AMFG, Tofu lees mixed feed group (TMFG. The CFG control used feed containing 20% soybean meal as the main protein source, while the AMFG and TMFG treatments used feed mixed with 20% dried Awamori-pressed lees or dried Tofu lees. The groups were fed mixed feed (volume to provide 100 g/d increase in body weight twice a day (10:00, 16:00. The klein grass hay and water was given ad libitum. The hay intake was measured at 08:00 and 16:00. Body weight and size measurements were taken once a month. At the end of the experiment, a blood sample was drawn from the jugular vein of each animal. The DCP and TDN intakes in AMFG and TMFG showed no significant difference to the CFG. Cumulative measurements of growth in body weight, withers height, chest depth, chest girth, and hip width over the 10 mo period in the AMFG and TMFG were similar to the CFG. By contrast, cumulative growth in body length and hip height in the AMFG and TMFG tended to be larger than the CFG. Cumulative growth in chest width in the AMFG was

  15. Unconstrained tripolar hip implants: effect on hip stability.

    Science.gov (United States)

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  16. Chip compacting press; Jido kirikuzu asshukuki

    Energy Technology Data Exchange (ETDEWEB)

    Oura, K. [Yuken Kogyo Co. Ltd., Kanagawa (Japan)

    1998-08-15

    The chips exhausted from various machine tools are massy, occupy much space and make working environment worse by staying added cutting oil to lower part. The chips are exhausted as a result of machining and have not constant quality. Even if used material is same the chips have various shapes and properties by kinds and machining methods of used machine tools, and are troublesome materials from a standpoint of their treatment. Pressing and solidification of the chips have frequently been tried. A chip compacting press introduced in this paper, a relatively cheap chip compacting press aimed for relatively small scale chip treatment, and has such characteristics and effects as follows. Chips are pressed and solidified by each raw material, so fractional management can be easily conducted. As casting metal chips and curled chips of iron and aluminum can be pressed to about 1/3 to 1/5 and about 1/40, respectively, space saving can be conducted. Chip compacting pressing upgrades its transporting efficiency to make possible to reduce its transporting cost. As chip solidification controls its oxidation and most cutting oil are removed, chips are easy to recycle. 2 figs., 1 tab.

  17. Effect of Ti interlayer on the bonding quality of W and steel HIP joint

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ji-Chao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Wang, Wanjing, E-mail: wjwang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Wei, Ran; Wang, Xingli; Sun, Zhaoxuan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Xie, Chunyi; Li, Qiang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Luo, Guang-Nan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Hefei Center for Physical Science and Technology, Hefei, 230022 (China); Hefei Science Center of Chinese Academy of Sciences, Hefei, 230027 (China)

    2017-03-15

    Tungsten (W) and steel bonding is one of the key technologies for blanket First Wall (FW) manufacture in thermal fusion reactor. The W/Steel joints are prone to fail without interlayer for the different thermo physical properties. To study the effect of titanium (Ti) interlayer on the bonding quality of W and steel joints, W/Steel Hot Isostatic Pressing (HIP) experiments with Ti interlayer were conducted under 930 °C, 100 MPa for 2 h. Intermetallics caused by atom interdiffusion would affect the bonding quality of W/Ti/Steel HIP joints, the bonding quality was evaluated by microstructure analysis and mechanical tests. All the HIP joints were well bonded and results showed no intermetallics occurred between W/Ti interfaces, meanwhile multiply phases were found between Ti/Steel interfaces. Shear tests indicated when Ti thickness was 100–500 μm, the maximum shear strength of W/Ti/Steel HIP joints would be up to around 151 MPa. Charpy impact tests showed the W/Ti/Steel HIP joints all broke in a brittle manner and the maximum Charpy impact energy was ∼0.192 J. Nano-indentation tests demonstrated W/Ti interfaces could be enhanced by solid solution hardening and formation of brittle phases has conducted high hardness across the Ti/Steel interfaces.

  18. BILATERAL PATHOLOGICAL HIP DISLOCATION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Yuriy E. Garkavenko

    2017-03-01

    Full Text Available Introduction. Pathological dislocation of the hip is one of the most severe complications of acute hematogenous osteomyelitis. The program of treatment for children with pathological hip dislocation is complex, but it has been sufficiently developed and implemented very successfully. At the same time, the available literature provides no cases of treating children with bilateral pathological hip dislocations after hematogenous osteomyelitis. There is no information on the incidence of such cases or in regards to remote functional results. Materials and methods. The results of the treatment of 18 children with bilateral pathological dislocation of the hip after hematogenous osteomyelitis are presented, which constituted 23.1% of the total number of patients (78 who underwent surgery in 2000–2016 for the diagnosis of pathological hip dislocation. Both hip joints were surgically operated on in 12 patients, while one hip joint was operated on in 6 patients. To assess the anatomical and functional state of hip joints, the clinical and roentgenological diagnostic techniques were used. Results and discussion. To stabilize and restore the function of the hip joints, 18 children underwent 30 surgical interventions: simple open hip reduction (19 and open hip reduction with hip arthroplasty with one (6 or two (5 demineralized osteochondral allogeneic grafts. The decision regarding the possibility of performing surgical intervention on the second hip joint was made only after a child's check-up examination was complete and after positive information about the anatomical and functional state of the operated hip joint was obtained. According to these criteria, 14 (77.8% children underwent surgical treatment of the second hip joint 1–1.5 years after the course of conservative measures to restore the range of motion in the previously operated hip joint. Over a period of 1–12 years, 17 patients were examined, 10 of which underwent an operation on both

  19. Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.

    Science.gov (United States)

    Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A

    2015-05-24

    Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.

  20. Hip fractures in old men

    International Nuclear Information System (INIS)

    Martinez Rondanelli, Alfredo

    2005-01-01

    Describe 289 hip fractures that were admitted at Hospital Universitario del Valle between November 1, 2003 and June 30, 2004. The patients had the first appointment at 2.7 days after the fallen, 60% the patients were women, at he age average were 75 years. In the hospital 228 patients were operated (79%). The surgery was realized in average at the twelve days after than they were admitted at the hospital. The days in the hospital were in average 17.5 days. The index of Katz at the admission was 3.96 and the Parker index was 6.56. The mortality in the hospital was of 30 patients (11%). The following during six months was in 114 patients of the people that were operated; we found loss of initial reduction the hip fracture in 10% and infection in 4%

  1. Pathogenesis of osteoporotic hip fractures.

    Science.gov (United States)

    McClung, Michael R

    2003-01-01

    Osteoporosis is characterized late in the course of the disease by an increased risk of fracture, particularly in the elderly. It occurs in both sexes, affecting approximately 8 million women and 2 million men aged > or = 50 years (1). While low bone density is a predictor of fractures, it is not the only determinant of fracture risk. Other factors include advanced age, altered bone quality, a personal or family history of falls, frailty, poor eyesight, debilitating diseases, and high bone turnover. A diet with sufficient calcium and vitamin D is important to minimize bone loss and, along with regular exercise, to maintain muscle strength. Bisphosphonates have been shown to reduce the risk of hip fracture. For elderly patients, the use of hip protectors may be used as a treatment of last resort. Regardless of the age of the patient, individual patient risk factors must be considered to target appropriate treatment and prevent fracture.

  2. Comparison of hip function and quality of life of total hip arthroplasty and resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint at 5 years.

    Science.gov (United States)

    Costa, Matthew L; Achten, Juul; Foguet, Pedro; Parsons, Nicholas R

    2018-03-12

    To compare the medium-term clinical effectiveness of total hip arthroplasty and resurfacing arthroplasty. Single centre, two-arm, parallel group, assessor blinded, randomised controlled trial with 1:1 treatment allocation. A large teaching hospital in England. 122 patients older than 18 years with severe arthritis of the hip joint, suitable for resurfacing arthroplasty of the hip. Patients were excluded if they were considered to be unable to adhere to trial procedures or complete questionnaires. Total hip arthroplasty (replacement of entire femoral head and neck); hip resurfacing arthroplasty (replacement of the articular surface of femoral head only, femoral neck remains intact). Both procedures replaced the articular surface of the acetabulum. The outcome measures were hip function assessed using the Oxford Hip Score (OHS) and health-related quality of life assessed using the EuroQol (EQ-5D). Patients were followed up annually for a minimum of 5 years. Outcome data were modelled using the generalised estimating equation methodology to explore temporal variations during follow-up. 60 patients were randomly assigned to hip resurfacing arthroplasty and 62 to total hip arthroplasty. 95 (78%) of the 122 original study participants provided data at 5 years. There was a small decrease in both hip functions and quality of life in both groups of patients each year during the 5-year follow-up period. However, there was no evidence of a significant difference between treatments group in the OHS (P=0.333) or the EQ-5D (P=0.501). We previously reported no difference in outcome in the first year after surgery. The current medium-term results also show no evidence of a difference in hip function or health-related quality of life in the 5 years following a total hip arthroplasty versus resurfacing arthroplasty. ISRCTN33354155. UKCRN 4093. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use

  3. Press kit. Areva in China

    International Nuclear Information System (INIS)

    2004-10-01

    The results achieved in the nuclear energy field illustrate the exemplary nature of the cooperation between France and China. Over 20 years, China has developed the nuclear technology for generating electricity, using the expertise and knowledge of the AREVA Group. AREVA has been present in China since 1986 and now employs 3,500 staff there. The group supplied the nuclear islands for 4 reactors at Daya Bay and Ling Ao as well as technology and equipment for 4 more reactors at the Qinshan II and Tianwan plants. AREVA has developed an ambitious program for transferring technology to the Chinese industry and developing local skills. The group's objective is to remain China's partner of choice in terms of its nuclear program. During an official visit to France in June 2004, China's Vice Premier Zeng Peiyan said he was in favor of 'overall and long-lasting cooperation between China and France in the field of nuclear energy'. AREVA took the opportunity to sign two letters of intent for cooperation over technology from its next generation of nuclear reactors. Electricity consumption forecasts report a need for 900 GW through 2020 and the country's objective is to increase nuclear-generated electricity from 1% to 4% of its total output (36 GW: the equivalent of around twenty 1,500 MWe reactors). An official decision to build 4 new reactors was announced in July 2004 and a further decision concerning another 4 reactors is expected in the near future. Various construction sites are being considered, mainly along the country's eastern coast. An official decision to build four duplicate reactors was announced n July 2004. In addition to these four duplicate reactors to be built on existing sites, China has decided to build four 3. generation reactors at Yangjiang and Sanmen. An international call for tender was launched on September 28, 2004. AREVA will reply to the tender by offering its EPR model. AREVA also aims to expand its Chinese operations into exploring and extracting

  4. Osteoporotic Hip and Spine Fractures

    OpenAIRE

    Cannada, Lisa K.; Hill, Brian W.

    2014-01-01

    Hip and spine fractures represent just a portion of the burden of osteoporosis; however, these fractures require treatment and often represent a major change in lifestyle for the patient and their family. The orthopedic surgeon plays a crucial role, not only in the treatment of these injuries but also providing guidance in prevention of future osteoporotic fractures. This review provides a brief epidemiology of the fractures, details the surgical techniques, and outlines the current treatment...

  5. Hip arthroscopy for femoroacetabular impingement

    Science.gov (United States)

    Nasser, Rima; Domb, Benjamin

    2018-01-01

    The purpose of this article is to give a general overview of femoroacetabular impingement (FAI) and how it could be treated arthroscopically, with some details about indications, the procedure itself and some of the complications associated with the surgery. FAI is a dynamic condition of the hip that can be a source of pain and disability and could potentially lead to arthritis. When symptomatic, and if conservative treatment fails, FAI can be addressed surgically. The goal of surgical treatment for FAI is to recreate the spherical contour of the femoral head, improve femoral offset, normalize coverage of the acetabulum, repair/reconstruct chondral damage and repair/reconstruct the labrum to restore normal mechanics and joint sealing. Advances in equipment and technique have contributed to an increase in the number of hip arthroscopy procedures performed worldwide and have made it one of the more common treatment options for symptomatic FAI. Hip arthroscopy is a procedure with an extremely steep and long learning curve. Cite this article: EFORT Open Rev 2018;3:121-129. DOI: 10.1302/2058-5241.3.170041 PMID:29780619

  6. [Technology of cementless hip endoprosthetics].

    Science.gov (United States)

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  7. A Hip Implant Energy Harvester

    Science.gov (United States)

    Pancharoen, K.; Zhu, D.; Beeby, S. P.

    2014-11-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω.

  8. A Hip Implant Energy Harvester

    International Nuclear Information System (INIS)

    Pancharoen, K; Zhu, D; Beeby, S P

    2014-01-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω

  9. Can shared care deliver better outcomes for patients undergoing total hip replacement?

    NARCIS (Netherlands)

    Rosendal, H.; Beekum, W.T. van; Nijhof, P.; Witte, L.P. de; Schrijvers, A.J.P.

    2000-01-01

    Objectives: To assess whether shared care for patients undergoing total hip replacement delivers better outcomes compared to care as usual. Design: Prospective, observational cohort study. Setting: Two regions in the Netherlands where different organisational health care models have been

  10. Is prophylactic fixation a cost-effective method to prevent a future contralateral fragility hip fracture?

    Science.gov (United States)

    Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J

    2010-02-01

    : A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for

  11. Structure and Interactions of a Dimeric Variant of sHIP, a Novel Virulence Determinant of Streptococcus pyogenes

    DEFF Research Database (Denmark)

    Diehl, Carl; Wisniewska, Magdalena; Frick, Inga-Maria

    2016-01-01

    HIP, which is secreted at higher levels by an invasive compared to a non-invasive strain of S. pyogenes. The present work presents a further characterization of the structural and functional properties of this bacterial protein. Biophysical and structural studies have shown that protein sHIP forms stable...... clearly indicated that the sHIP mutant appear only as dimers in solution confirming the importance of the interfacial residues for protein oligomerisation. Furthermore, we could show that the sHIP mutant interacts with intact histidine-rich glycoprotein (HRG) and the histidine-rich repeats in HRG......, and inhibits their antibacterial activity to the same or even higher extent as compared to the wild type protein sHIP. We determined the crystal structure of the sHIP mutant, which, as a result of the high quality of the data, allowed us to improve the existing structural model of the protein. Finally...

  12. Tensile Fracture Behavior of 316L Austenitic Stainless Steel Manufactured by Hot Isostatic Pressing

    Science.gov (United States)

    Cooper, A. J.; Brayshaw, W. J.; Sherry, A. H.

    2018-02-01

    Herein we investigate how the oxygen content in hot isostatically pressed (HIP'd) 316L stainless steel affects the mechanical properties and tensile fracture behavior. This work follows on from previous studies, which aimed to understand the effect of oxygen content on the Charpy impact toughness of HIP'd steel. We expand on the work by performing room-temperature tensile testing on different heats of 316L stainless steel, which contain different levels of interstitial elements (carbon and nitrogen) as well as oxygen in the bulk material. Throughout the work we repeat the experiments on conventionally forged 316L steel as a reference material. The analysis of the work indicates that oxygen does not contribute to a measureable solution strengthening mechanism, as is the case with carbon and nitrogen in austenitic stainless steels (Werner in Mater Sci Eng A 101:93-98, 1988). Neither does oxygen, in the form of oxide inclusions, contribute to precipitation hardening due to the size and spacing of particles. However, the oxide particles do influence fracture behavior; fractography of the failed tension test specimens indicates that the average ductile dimple size is related to the oxygen content in the bulk material, the results of which support an on-going hypothesis relating oxygen content in HIP'd steels to their fracture mechanisms by providing additional sites for the initiation of ductile damage in the form of voids.

  13. A study on improving mechanical properties of porous HA tissue engineering scaffolds by hot isostatic pressing

    International Nuclear Information System (INIS)

    Zhao Jing; Xiao Suguang; Lu Xiong; Wang Jianxin; Weng Jie

    2006-01-01

    Various interconnected porous hydroxyapatite (HA) ceramic scaffolds are universally used to induct the tissue growth for bone repair and replacement, and serve to support the adhesion, transfer, proliferation and differentiation of cells. Impregnation of polyurethane sponges with a ceramic slurry is adopted to produce highly porous HA ceramic scaffolds with a 3D interconnected structure. However, high porosity always accompanies a decrease in the strength of the HA ceramic scaffolds. Therefore, it is significant to improve the strength of the HA ceramic scaffolds with highly interconnected porosity so that they are more suitable in clinical applications. In this work, highly porous HA ceramic scaffolds are first produced by the polymer impregnation approach, and subsequently further sintered by hot isostatic pressing (HIP). The phase composition, macro- and micro-porous structure, sintering and mechanical properties of the porous HA scaffolds are investigated by x-ray diffraction (XRD), scanning electron microscopy (SEM), nanoindentation analysis and compressive test. The experimental results show that the nanohardness and compressive strength of HIP-sintered porous HA ceramics are higher than those of commonly sintered HA scaffolds. The HIP technique can effectively improve the sintering property and densification of porous HA ceramic scaffolds, so inducing an increase in the compression strength

  14. M3FT-17OR0301070211 - Preparation of Hot Isostatically Pressed AgZ Waste Form Samples

    Energy Technology Data Exchange (ETDEWEB)

    Jubin, Robert Thomas [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bruffey, Stephanie H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jordan, Jacob A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-10-01

    The production of radioactive iodine-bearing waste forms that exhibit long-term stability and are suitable for permanent geologic disposal has been the subject of substantial research interest. One potential method of iodine waste form production is hot isostatic pressing (HIP). Recent studies at Oak Ridge National Laboratory (ORNL) have investigated the conversion of iodine-loaded silver mordenite (I-AgZ) directly to a waste form by HIP. ORNL has performed HIP with a variety of sample compositions and pressing conditions. The base mineral has varied among AgZ (in pure and engineered forms), silver-exchanged faujasite, and silverexchanged zeolite A. Two iodine loading methods, occlusion and chemisorption, have been explored. Additionally, the effects of variations in temperature and pressure of the process have been examined, with temperature ranges of 525°C–1,100°C and pressure ranges of 100–300 MPa. All of these samples remain available to collaborators upon request. The sample preparation detailed in this document is an extension of that work. In addition to previously prepared samples, this report documents the preparation of additional samples to support stability testing. These samples include chemisorbed I-AgZ and pure AgI. Following sample preparation, each sample was processed by HIP by American Isostatic Presses Inc. and returned to ORNL for storage. ORNL will store the samples until they are requested by collaborators for durability testing. The sample set reported here will support waste form durability testing across the national laboratories and will provide insight into the effects of varied iodine content on iodine retention by the produced waste form and on potential improvements in waste form durability provided by the zeolite matrix.

  15. Cost-effectiveness of hip protectors in frail institutionalized elderly

    NARCIS (Netherlands)

    van Schoor, N.M.; de Bruyne, M.C.; van der Roer, N.; Lommerse, E.; van Tulder, M.; Bouter, L.M.; Lips, P.T.A.M.

    2004-01-01

    A randomized controlled trial was performed to examine the cost-effectiveness of external hip protectors in the prevention of hip fractures. Since the hip protectors were not effective in preventing hip fractures in our study, the main objective became to examine whether the use of hip protectors

  16. Manufacturing of small scale W monoblock mockups by hot radial pressing

    International Nuclear Information System (INIS)

    Visca, Eliseo; Testani, C.; Libera, S.; Sacchetti, M.

    2003-01-01

    In the frame of the European Technology R and D programme for International thermonuclear experimental reactor (ITER) and in the area of high heat flux plasma facing components (HHFC), representative small-scale mock-ups were manufactured and tested to compare different concepts and joining technologies (i.e. active brazing, hot isostatic pressing (HIPping), diffusion bonding, etc.). On the basis of the results obtained by thermal fatigue tests, the monoblock concept resulted to be the most robust one, particularly when the HIPping manufacturing technology is used. Within this programme, ENEA developed an alternative technique for manufacturing plasma-facing components with a monoblock geometry of the ITER machine. The basic idea of this technique, named hot radial pressing (HRP), is to perform a radial diffusion bonding between the cooling tube and the armour tile by pressurising the internal tube only and by keeping the process parameters within the range in which the thermo-mechanical properties of the copper alloys are not yet degraded. The HRP is performed by a standard furnace, in which only a section of the canister is heated. The manufacturing procedure and the results of the screening and fatigue thermal tests performed on the ENEA mock-ups are reported in this paper

  17. The Relationship Between Hip Strength and the Y-Balance Test.

    Science.gov (United States)

    Wilson, Benjamin R; Robertson, Kaley E; Burnham, Jeremy M; Yonz, Michael C; Ireland, Mary Lloyd; Noehren, Brian

    2017-07-17

    The Y-Balance Test was developed as a test of dynamic postural control and has been shown to be predictive of lower extremity injury. However, the relationship between hip strength and performance on the Y-Balance Test has not been fully elucidated. The goal of this study was to identify the relationship between components of isometric hip strength and the Y-Balance Test, to provide clinicians better guidance as to specific areas of muscle performance to address in the event of poor performance on the Y-Balance Test. Laboratory Study. Biomechanics Laboratory. Seventy-three healthy participants, 40 males and 33 females, volunteered for this study. None. Participants completed the Y-Balance Test on the right leg. We then measured peak isometric torque in hip external rotation, abduction, and extension. Correlations were calculated between torque measurements, normalized for mass, and Y-Balance Test performance. Significant relationships were used in linear regression models to determine which variables were predictive of the Y-Balance Test performance. We found significant positive correlations between Y-Balance Test performance and hip abduction strength. We also found correlations between the Y-Balance Test and hip extension and external rotation strengths. Linear regression analysis showed hip abduction to be the only significant predictor of Y- Balance performance. We found the strongest association between the Y-Balance Test and hip abduction strength. We also showed smaller but significant associations with hip extension and external rotation strength. When entered into a linear regression analysis, hip abduction strength was the only significant predictor of Y-Balance performance. Using this information, practitioners should look to hip abduction strength when patients exhibit deficits in the Y-Balance Test.

  18. Education, marital status, and risk of hip fractures in older men and women: the CHANCES project.

    Science.gov (United States)

    Benetou, V; Orfanos, P; Feskanich, D; Michaëlsson, K; Pettersson-Kymmer, U; Ahmed, L A; Peasey, A; Wolk, A; Brenner, H; Bobak, M; Wilsgaard, T; Schöttker, B; Saum, K-U; Bellavia, A; Grodstein, F; Klinaki, E; Valanou, E; Papatesta, E-M; Boffetta, P; Trichopoulou, A

    2015-06-01

    The role of socioeconomic status in hip fracture incidence is unclear. In a diverse population of elderly, higher education was found to be associated with lower, whereas living alone, compared to being married/cohabiting, with higher hip fracture risk. Educational level and marital status may contribute to hip fracture risk. The evidence on the association between socioeconomic status and hip fracture incidence is limited and inconsistent. We investigated the potential association of education and marital status with hip fracture incidence in older individuals from Europe and USA. A total of 155,940 participants (79 % women) aged 60 years and older from seven cohorts were followed up accumulating 6456 incident hip fractures. Information on education and marital status was harmonized across cohorts. Hip fractures were ascertained through telephone interviews/questionnaires or through record linkage with registries. Associations were assessed through Cox proportional hazard regression adjusting for several factors. Summary estimates were derived using random effects models. Individuals with higher education, compared to those with low education, had lower hip fracture risk [hazard ratio (HR) = 0.84, 95 % confidence interval (CI) 0.72-0.95]. Respective HRs were 0.97 (95 % CI 0.82-1.13) for men and 0.75 (95 % CI 0.65-0.85) for women. Overall, individuals living alone, especially those aged 60-69 years, compared to those being married/cohabiting, tended to have a higher hip fracture risk (HR = 1.12, 95 % CI 1.02-1.22). There was no suggestion for heterogeneity across cohorts (P heterogeneity > 0.05). The combined data from >150,000 individuals 60 years and older suggest that higher education may contribute to lower hip fracture risk. Furthermore, this risk may be higher among individuals living alone, especially among the age group 60-69 years, when compared to those being married/cohabiting.

  19. Kinematic relationship between rotation of lumbar spine and hip joints during golf swing in professional golfers.

    Science.gov (United States)

    Mun, Frederick; Suh, Seung Woo; Park, Hyun-Joon; Choi, Ahnryul

    2015-05-14

    Understanding the kinematics of the lumbar spine and hip joints during a golf swing is a basic step for identifying swing-specific factors associated with low back pain. The objective of this study was to examine the kinematic relationship between rotational movement of the lumbar spine and hip joints during a golf swing. Fifteen professional golfers participated in this study with employment of six infrared cameras to record their golf swings. Anatomical reference system of the upper torso, pelvis and thigh segments, and the location of each hip and knee joint were defined by the protocols of the kinematic model of previous studies. Lumbar spine and hip joint rotational angle was calculated utilizing the Euler angle method. Cross-correlation and angle-angle plot was used to examine the degree of kinematic relationship between joints. A fairly strong coupling relationship was shown between the lumbar spine and hip rotational movements with an average correlation of 0.81. Leading hip contribution to overall rotation was markedly high in the early stage of the downswing, while the lumbar spine contributed greater towards the end of the downswing; however, the relative contributions of the trailing hip and lumbar spine were nearly equal during the entire downswing. Most of the professional golfers participated in this study used a similar coordination strategy when moving their hips and lumbar spine during golf swings. The rotation of hips was observed to be more efficient in producing the overall rotation during the downswing when compared to the backswing. These results provide quantitative information to better understand the lumbar spine and hip joint kinematic characteristics of professional golfers. This study will have great potential to be used as a normal control data for the comparison with kinematic information among golfers with low back pain and for further investigation of golf swing-specific factors associated with injury.

  20. Machine learning for activity recognition: hip versus wrist data

    International Nuclear Information System (INIS)

    Trost, Stewart G; Zheng, Yonglei; Wong, Weng-Keen

    2014-01-01

    Problem addressed: Wrist-worn accelerometers are associated with greater compliance. However, validated algorithms for predicting activity type from wrist-worn accelerometer data are lacking. This study compared the activity recognition rates of an activity classifier trained on acceleration signal collected on the wrist and hip. Methodology: 52 children and adolescents (mean age 13.7  ±  3.1 year) completed 12 activity trials that were categorized into 7 activity classes: lying down, sitting, standing, walking, running, basketball, and dancing. During each trial, participants wore an ActiGraph GT3X+ tri-axial accelerometer on the right hip and the non-dominant wrist. Features were extracted from 10-s windows and inputted into a regularized logistic regression model using R (Glmnet + L1). Results: Classification accuracy for the hip and wrist was 91.0% ± 3.1% and 88.4% ± 3.0%, respectively. The hip model exhibited excellent classification accuracy for sitting (91.3%), standing (95.8%), walking (95.8%), and running (96.8%); acceptable classification accuracy for lying down (88.3%) and basketball (81.9%); and modest accuracy for dance (64.1%). The wrist model exhibited excellent classification accuracy for sitting (93.0%), standing (91.7%), and walking (95.8%); acceptable classification accuracy for basketball (86.0%); and modest accuracy for running (78.8%), lying down (74.6%) and dance (69.4%). Potential Impact: Both the hip and wrist algorithms achieved acceptable classification accuracy, allowing researchers to use either placement for activity recognition. (paper)

  1. A high-fidelity model for coupling flow and mechanical deformation of the porous paper web - a key to improved understanding of dewatering and rewet at the press section in paper making

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Trebotich, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wang, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Xu, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Turpin, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-05

    The U.S. pulp and paper industry is the third-largest manufacturing user of energy, with an energy demand of 2,540 trillion Btu in 2010. Within the papermaking process, drying consumes over 400 trillion Btu annually which makes it one of the largest energy saving opportunities. In the 2014 Forest Products Industry Technology Roadmap, it is concluded that increasing the paper web solid content entering the dryer section from the current 45- 55 percent to approaching 65 percent, which would save 1.0 MMBtu per ton or 20 percent of the energy used in drying, is one of the most needed technology breakthroughs to achieve a more sustainable approach for manufacturing pulp and paper products. Achieving such significant energy savings highly depends on understanding the fundamental dynamics of the wet press process and then developing optimized solutions for design of more energy-efficient press processes and equipment. The objective of this project is to develop reliable computational capabilities to accurately simulate the flow of water from/to the porous pulp medium (dewatering/rewetting) during the pressing process in paper making.

  2. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  3. Production of press moulds by plasma spray forming process

    International Nuclear Information System (INIS)

    Borisov, Y.; Myakota, I.; Polyakov, S.

    2001-01-01

    Plasma spray forming process for production of press moulds which are used for manufacture of articles from plastics was developed. The press moulds were produced by plasma spraying of Cu-Al-Fe-alloy powder on surface of a master model. The master models were made from non-metallic materials with heat resistance below 70 C (wood, gypsum etc). Double cooling system which provides for a control of surface model temperature and quenching conditions of sprayed material was designed. It made possible on the one hand to support model surface temperature below 70 C and on the other hand to provide for temperature conditions of martensite transformation in Cu-Al-system with a fixation of metastable ductile α + β 1 -phase. This allowed to decrease residual stresses in sprayed layer (up to 0,5-2,5 MPa), to increase microhardness of the coating material (up to 1200-1800 MPa) and its ductility (σ B = 70-105 MPa, δ = 6-12 %). This plasma spray forming process makes possible to spray thick layers (5-20 mm and more) without their cracking and deformation. The process is used for a production of press moulds which are applied in shoes industry, for fabrication of toys, souvenirs etc. (author)

  4. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  5. Hip biomechanics during stair ascent and descent in people with and without hip osteoarthritis.

    Science.gov (United States)

    Hall, Michelle; Wrigley, Tim V; Kean, Crystal O; Metcalf, Ben R; Bennell, Kim L

    2017-07-01

    Hip osteoarthritis (OA) is often associated with pain and impaired function. Understanding biomechanical alterations in patients with hip OA during challenging activities such as stair use is important to inform treatments. The aim of this study was to determine whether kinematics and kinetics during stair ambulation differed between people with hip OA and healthy controls. Fifteen participants with symptomatic and radiographic hip OA and 15 asymptomatic healthy controls underwent 3-D motion analysis during stair ascent and descent. Trunk, pelvis, and hip kinematics as well as hip kinetics were evaluated. Analyses were performed unadjusted and adjusted for speed and leg length. In both the unadjusted and adjusted analyses, participants with hip OA ascended stairs with less hip range of motion in all three planes and a lower peak external rotation moment compared to controls. In the unadjusted analysis, hip OA participants descended stairs with greater ipsilateral trunk lean, less sagittal plane range of motion, lower peak extension moment, lower peak external rotation moment, and greater hip adduction moment impulse compared to controls. In the adjusted results, peak internal rotation moment and hip adduction moment impulse were greater in hip OA participants compared to controls. Findings show that individuals with hip OA display limited range of hip joint movement, particularly during stair ascent, and overall indicate the use of strategies (e.g., trunk lean; lower peak external rotation moment; higher adduction moment impulse) that implicate altered hip abductor function. Future research is required to further understand the implications of these findings on hip OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1505-1514, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Void formation in ODS EUROFER produced by hot isostatic pressing

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Y.; Monge, M.A.; Munoz, A.; Leguey, T.; Pareja, R. [Madrid Univ. Carlos-3, Dept. de Fisica (Spain); Castro, V. de [Oxford Univ., Dept. of Materials (United Kingdom)

    2007-07-01

    Full text of publication follows: An obstacle in the development of oxide dispersion strengthened (ODS) steels for structural applications in fusion reactors is the toughness lack of the material produced by powder metallurgy and consolidated by hot isostatic pressing (HIP). In particular, ODS EUROFER steel with Y{sub 2}O{sub 3} particles appears to exhibit poor impact properties. To asses the capabilities of this material, it is necessary elucidate if its failure is an inherent characteristic of the production process that can not be mitigated by normalizing and tempering treatments. In order to investigate this particular point, the evolution of the structural defects retained in the ODS material during isochronal annealing has been probed by positron annihilation spectroscopy. The present study has been performed on bail milled EUROFER powders consolidated by HIP, containing 0.25 wt % Y{sub 2}O{sub 3} and without Y{sub 2}O{sub 3}. For comparison, un-milled EUROFER powder consolidated under identical conditions, and as-received EUROFER97 plate produced by Boehler AG have been also investigated. Samples from these four materials were isochronally annealed for 90 min up to 1323 K. Materials produced from milled powders had a longer positron lifetime than the one produced from un-milled powder or the EUROFER plate. In the material containing Y{sub 2}O{sub 3}, i.e. in ODS EUROFER, annealing above 723 K produced a continuous increase in the mean positron lifetime <{tau}> up to reach a maximum value of 208 ps after annealing at 1223 K. A similar annealing behavior was observed for Y{sub 2}O{sub 3}-free milled EUROFER (milled EUROFER), but the <{tau}> value steeply changed from {approx}160 ps at 823 K to {approx}200 ps after annealing at 1023 K. Subsequent anneals above this temperature produced meaningless changes in <{tau}>. The <{tau}> increase in milled EUROFER was accompanied by the intensity increase of a lifetime component of {approx}360 ps that is characteristic

  7. COMPLEX FUNCTIONAL ASSESSMENT OF THE HIP JOINT.

    Directory of Open Access Journals (Sweden)

    Maya S. Krastanova

    2015-09-01

    Full Text Available Introduction: In relation to the study reporting the effects of applying phased complex rehabilitation in patients with total hip arthroplasty, it has been concluded that the everyday clinical practice in Bulgaria does not apply complex examination, giving an objective picture about the extent of functional status of patients with trauma and diseases of the hip. Aim: The main goal of this report is to present a test which incorporates all known and routine research and in which the total number of points determines the functional status of patients with trauma and diseases of the hip. Material and Methods: Based on the Hip dysfunction and Osteoarthritis Outcome Score, the Harris Hip Score modified test, scale D’Aubigne and Postel and Iowa’s test for complex functional evaluation of the hip joint, we have developed a test including information about the degree of pain; goniometry and manual muscle testing of the hip; locomotor test – type of gait and adjuvants; test for Daily Activities of Life. The test has been developed on the basis of expert assessment by doctors and physiotherapists of the proposed indicators for evaluation and determination of the weighting factors’ contribution to the general condition of the patient. Conclusion: The developed and tested method of complex functional assessment of the hip joint enables our colleagues, dealing with trauma and diseases of the hip, to use it in various research and scientific projects, as well as in general medical practice.

  8. PRESS FREEDOM IN SINGAPORE AND MALAYSIA: DEFAMATION

    Directory of Open Access Journals (Sweden)

    Georgia Kate Chapman

    2015-04-01

    Full Text Available This paper focuses on the arguments around restriction on freedom of the press in the Strong States of Singapore and Malaysia. It assesses the presence of constraints on press freedoms in democratic western countries imposed by corporation rather than state and the similar effects that these constraints may have on bias present in publicly accessible news reporting. It argues that independence of the press does not just require protection from legal and executive regulation, but also protection from large media corporations and their political alignments. This report will assess the bias of reporting and news media publication that exists in Malaysia and Singapore due to legislative and regulatory constraints as opposed to bias that exist in the western liberal democratic nations of the United Kingdom (UK and the United States of America (USA due to Media Organisation control.

  9. CSR-communication in the Business Press

    DEFF Research Database (Denmark)

    Morsing, Mette; Langer, Roy

    on a broadly encompassing and ambiguous definition of CSR. Our empirical data shows how the business press in its discourse on CSR provides no clarity on the definition of CSR in terms of a coherent motive, a dominant stakeholder or a consistent issue, but rather maintains ambiguity and imprecision about......In this paper we analyze the construction of corporate social responsibility in the business press as an act of strategic ambiguity. While corporate social responsibility (CSR) generally evokes positive associations in public opinion, this paper demonstrates that these associations are based...... is systematically maintained in the business press. We refer to this process as strategic ambiguity. The paper discusses the potential value and limitations of framing CSR in a state of strategic ambiguity in the context of the concurrent rethinking of the role of business in modern welfare societies....

  10. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kjærsgaard-Andersen, Per; Kehlet, Henrik

    2014-01-01

    STUDY DESIGN: Retrospective review of prospectively collected data. OBJECTIVE: To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors. METHODS: Prospective data on preoperative patient.......31-3.40)] but not hospital stay of hip...

  11. Resolving controversies in hip fracture care: the need for large collaborative trials in hip fractures

    NARCIS (Netherlands)

    Bhandari, Mohit; Sprague, Sheila; Schemitsch, Emil H.; Einhorn, Thomas; Guyatt, Gordon H.; Haidukewych, George; Keating, John; Koval, Kenneth; Rosen, Clifford; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Motsitsi, Silas; Pei, Fuxing; Yang, Tian-fu; Zhou, Zong-ke; Arora, Shobha; Babhulkar, Sushrut; Bhargava, Rakesh; Desai, Mohan M.; Dhillon, Mandeep S.; Gill, Harpreet Singh; Goel, S. C.; Reddy, A. V. Gurava; Jain, Anil K.; Kalore, Niraj V.; Kammatkar, Nitin; Kumar, Vijay; Malhorta, Rajesh; Marthandam, S. S. K.; Pankaj, Amite; Patinharayil, Gopinathan; Rai, B. Sachidanand; Ramteke, Alankar Ambadas; Sancheti, Parag K.; Thakkar, Navin N.; Thomas, George S.; Robinson, Dror; Steinberg, Ely; Higuchi, Fujio; Kawamura, Sumito; Ohashi, Hirotsugu; Sawaguchi, Takeshi; Park, Myung-Sik; Yun, Ho Hyun; Poduval, Murali; Siddiqui, Ahmed; Chang, Je-Ken; Wang, Gwo-Jaw; Goslings, J. Carel

    2009-01-01

    Hip fractures are a significant cause of morbidity and mortality worldwide and the burden of disability associated with hip fractures globally vindicate the need for high-quality research to advance the care of patients with hip fractures. Historically, large, multi-centre randomized controlled

  12. Influence of hip dysplasia on the development of osteoarthritis of the hip

    NARCIS (Netherlands)

    A.M. Lievense (Annet); S.M. Bierma-Zeinstra (Sita); A.P. Verhagen (Arianne); J.A.N. Verhaar (Jan); B.W. Koes (Bart)

    2004-01-01

    textabstractBackground: It has been suggested that in some patients with primary hip osteoarthritis (OA), the disease occurs as a consequence of acetabular dysplasia or hip dysplasia (HD). Objective: To carry out a systematic review to investigate the association between acetabular dysplasia and hip

  13. Internet Marketing with WordPress

    CERN Document Server

    Mercer, David

    2011-01-01

    The book's accompanying Interactive learning environment on siteprebuilder.com gives you an online place to enhance and extend your practical experience through exercises, consolidate your learning and theoretical knowledge with marked quizzes, interaction with your WordPress marketing community, and fun and exciting extras such as challenges and competitions. This book is for people already using WordPress, who want more visitors, better visitors, and to convert more of them into paying customers. No prior marketing experience is required, although a basic understanding of either hosted or se

  14. WordPress 24-hour trainer

    CERN Document Server

    Plumley, George

    2015-01-01

    Create and expand feature-rich sites with no programming experience Ready to build, maintain, and expand your web site with WordPress but have no prior programming experience? WordPress 24-Hour Trainer, 3rd Edition is your book-and-video learning solution that walks you step-by-step through all the important features you will need to know. Lessons range from focused, practical everyday tasks to more advanced, creative features. Learn from an industry professional how to enter content, create pages, manage menus, utilize plug-ins, connect to social media, create membership and e-commerce site

  15. Improving Dryer and Press Efficiencies Through Combustion of Hydrocarbon Emissions

    Energy Technology Data Exchange (ETDEWEB)

    Sujit Banerjee

    2005-10-31

    Emission control devices on dryers and presses have been legislated into the industry, and are now an integral part of the drying system. These devices consume large quantities of natural gas and electricity and down-sizing or eliminating them will provide major energy savings. The principal strategy taken here focuses on developing process changes that should minimize (and in some cases eliminate) the need for controls. A second approach is to develop lower-cost control options. It has been shown in laboratory and full-scale work that Hazardous Air Pollutants (HAPs) emerge mainly at the end of the press cycle for particleboard, and, by extension, to other prod-ucts. Hence, only the air associated with this point of the cycle need be captured and treated. A model for estimating terpene emissions in the various zones of veneer dryers has been developed. This should allow the emissions to be concentrated in some zones and minimized in others, so that some of the air could be directly released without controls. Low-cost catalysts have been developed for controlling HAPs from dryers and presses. Catalysts conventionally used for regenerative catalytic oxidizers can be used at much lower temperatures for treating press emissions. Fluidized wood ash is an especially inexpensive mate-rial for efficiently reducing formaldehyde in dryer emissions. A heat transfer model for estimating pinene emissions from hot-pressing strand for the manufacture of flakeboard has been constructed from first principles and validated. The model shows that most of the emissions originate from the 1-mm layer of wood adjoining the platen surface. Hence, a simple control option is to surface a softwood mat with a layer of hardwood prior to pressing. Fines release a disproportionate large quantity of HAPs, and it has been shown both theo-retically and in full-scale work that particles smaller than 400 µm are principally responsible. Georgia-Pacific is considering green

  16. Investigation of hot- iso-static press process for tungsten target samples

    International Nuclear Information System (INIS)

    Xu Yongli; Zhang Jinquan; Li Huaqing

    2006-01-01

    Zr and stainless steel (S.S.) were selected respectively as the cladding materials of W target. The e-beam weld was used to prepare the W-Zr and W-S.S. small samples for hot iso-static press (HIP) process. The technology parameters of HIP were investigated at 1200, 1300, 1400 degree C and 180 MPa, respectively. The micro-morphology of the interface, diffusion depths and composition as well as their micro-hardness were observed and determined. The bonding of W-Zr and W-S.S. is very well under the testing conditions. There is no any pore or micro-crack in the interface, and there is no grain growth of W below 1400 degree C either. The diffusion of Zr to W at the interface of W-Zr is preferred during HIP process, and the diffusion depths under testing conditions are 6-13 μm. The diffusion of W and Fe is considerable at the interface of W-S.S. Its depth is about 13 μm, and the diffusion of Cr and Ni is mall. The hardness at the interface of W-Zr and W-S.S. shows that a diffusion layer is present for both interface. A part of stainless steel cladding was melted after HIP contained the oxygen absorber Zr at 1300 degree C and 180 MPa. Therefore, 1200 degree C and 180 MPa is suitable for W-S.S. without Zr, but 1300 or 1400 degree C and 180 MPa is better for W-Zr. (authors)

  17. Surgical hip dislocation for treatment of cam femoroacetabular impingement

    Directory of Open Access Journals (Sweden)

    Milind M Chaudhary

    2015-01-01

    Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.

  18. AUPress: A Comparison of an Open Access University Press with Traditional Presses

    Science.gov (United States)

    McGreal, Rory; Chen, Nian-Shing

    2011-01-01

    This study is a comparison of AUPress with three other traditional (non-open access) Canadian university presses. The analysis is based on the rankings that are correlated with book sales on Amazon.com and Amazon.ca. Statistical methods include the sampling of the sales ranking of randomly selected books from each press. The results of one-way…

  19. Bullying the media : Cultural and climato-economic readings of press repression versus press freedom

    NARCIS (Netherlands)

    Van de Vliert, E.

    Journalists and media assistants in many places are murdered, imprisoned, censored, threatened, and similarly harrassed. Here I document that, and explain why, there are three climato-economic niches of press repression versus press freedom as part of broader syndromes of national culture. A

  20. Comparison of structure, morphology, and leach characteristics of multi-phase ceramics produced via melt processing and hot isostatic pressing

    Science.gov (United States)

    Dandeneau, Christopher S.; Hong, Tao; Brinkman, Kyle S.; Vance, Eric R.; Amoroso, Jake W.

    2018-04-01

    Melt processing of multi-phase ceramic waste forms offers potential advantages over traditional solid-state synthesis methods given both the prevalence of melters currently in use and the ability to reduce the possibility of airborne radionuclide contamination. In this work, multi-phase ceramics with a targeted hollandite composition of Ba1.0Cs0.3Cr1.0Al0.3Fe1.0Ti5.7O16 were fabricated by melt processing at 1675 °C and hot isostatic pressing (HIP) at 1250 and 1300 °C. X-ray diffraction analysis (XRD) confirmed hollandite as the major phase in all specimens. Zirconolite/pyrochlore peaks and weaker perovskite reflections were observed after melt processing, while HIP samples displayed prominent perovskite peaks and low-intensity zirconolite reflections. Melt processing produced specimens with large (>50 μm) well-defined hollandite grains, while HIP yielded samples with a more fine-grained morphology. Elemental analysis showed "islands" rich in Cs and Ti across the surface of the 1300 °C HIP sample, suggesting partial melting and partitioning of Cs into multiple phases. Photoemission data revealed multiple Cs 3d spin-orbit pairs for the HIP samples, with the lower binding energy doublets likely corresponding to Cs located in more leachable phases. Among all specimens examined, the melt-processed sample exhibited the lowest fractional release rates for Rb and Cs. However, the retention of Sr and Mo was greater in the HIP specimens.

  1. Factors that influence exercise activity among women post hip fracture participating in the Exercise Plus Program.

    Science.gov (United States)

    Resnick, Barbara; Orwig, Denise; D'Adamo, Christopher; Yu-Yahiro, Janet; Hawkes, William; Shardell, Michelle; Golden, Justine; Zimmerman, Sheryl; Magaziner, Jay

    2007-01-01

    Using a social ecological model, this paper describes selected intra- and interpersonal factors that influence exercise behavior in women post hip fracture who participated in the Exercise Plus Program. Model testing of factors that influence exercise behavior at 2, 6 and 12 months post hip fracture was done. The full model hypothesized that demographic variables; cognitive, affective, physical and functional status; pain; fear of falling; social support for exercise, and exposure to the Exercise Plus Program would influence self-efficacy, outcome expectations, and stage of change both directly and indirectly influencing total time spent exercising. Two hundred and nine female hip fracture patients (age 81.0 +/- 6.9), the majority of whom were Caucasian (97%), participated in this study. The three predictive models tested across the 12 month recovery trajectory suggest that somewhat different factors may influence exercise over the recovery period and the models explained 8 to 21% of the variance in time spent exercising. To optimize exercise activity post hip fracture, older adults should be helped to realistically assess their self-efficacy and outcome expectations related to exercise, health care providers and friends/peers should be encouraged to reinforce the positive benefits of exercise post hip fracture, and fear of falling should be addressed throughout the entire hip fracture recovery trajectory.

  2. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    Science.gov (United States)

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  3. Seasonality of service provision in hip and knee surgery: a possible contributor to waiting times? A time series analysis.

    Science.gov (United States)

    Upshur, Ross E G; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad

    2006-03-01

    The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100,000 population for all hip and knee replacements. There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.

  4. The effects of HIP processing on microstructure and phase relations in. alpha. sub 2 -base titanium aluminides

    Energy Technology Data Exchange (ETDEWEB)

    Saqib, M. (Dept. of Mechanical and Materials Engineering, Wright State Univ., Dayton, OH (United States)); Apgar, L.S.; Eylon, D. (Graduate Materials Engineering, Univ. of Dayton, OH (United States)); Weiss, I. (Dept. of Mechanical and Materials Engineering, Wright State Univ., Dayton, OH (United States))

    1992-05-30

    Cast {alpha}{sub 2}-base alloy (Ti-25Al-10Nb-3V-1Mo, at.%) underwent hot isostatic pressing (HIP) at temperatures ranging from 925 to 1125degC and pressures of 100-270 MPa. Effects of temperature and pressure during HIP, on microstructure and volume fraction of the phases present, were investigated. Microstructural characterization was carried out using optical microscopy and transmission electron microscopy. The phases present were identified using selected area and convergent beam electron diffraction. Volume fraction of the phases was determined using X-ray diffraction. Optimum refinement in the microstructure was obtained following HIP at 1020degC/262 MPa/6 h. The volume fraction of the B2 phase increased from 12% in the as-cast condition to 45% following HIP at 982degC/262 MPa/6 h. Experiments on forged Ti-25Al-10Nb-3V-1Mo alloy demonstrated that changes in volume fraction of the phases owing to HIP was applicable for cast as well as forged material. Sharp decrease in the volume fraction of the B2 phase was observed when as-HIP materials were aged at elevated temperature. Possible mechanisms of these changes in the phase stability and microstructure are discussed. (orig.).

  5. Seasonality of service provision in hip and knee surgery: A possible contributor to waiting times? A time series analysis

    Directory of Open Access Journals (Sweden)

    Upshur Ross EG

    2006-03-01

    Full Text Available Abstract Background The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. Methods We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100 000 population for all hip and knee replacements. Results There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p 2Autoreg = 0.85 seasonality was identified in the data. Conclusion Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.

  6. Comparison of the responsiveness of the Harris Hip Score with generic measures for hip function in osteoarthritis of the hip.

    NARCIS (Netherlands)

    Hoeksma, H.L.; Ende, C.H.M. van den; Ronday, H.K.; Heering, A.; Breedveld, F.C.; Dekker, J.

    2003-01-01

    OBJECTIVE: To compare responsiveness of the Harris Hip Score with generic measures (that is, the Short Form-36 (SF-36), and a test of walking speed and pain during walking) in patients with osteoarthritis (OA) of the hip. METHOD: The first 75 cases within the population of a randomised clinical

  7. Unilateral hip osteoarthritis: can we predict the outcome of the other hip?

    International Nuclear Information System (INIS)

    Vossinakis, I.C.; Georgiades, G.; Hartofilakidis, G.; Kafidas, D.

    2008-01-01

    The objective of this study was to define, in unilateral hip osteoarthritis (OA), factors predicting the outcome of the other hip. We examined the anteroposterior radiographs of the pelvis of 95 white patients with unilateral idiopathic (56 patients) or secondary to congenital hip diseases (39 patients) OA. The other hip was free from symptoms (pain or limping) at the initial examination and without radiographic evidence of OA; it was what we call a ''normal'' hip. Two parameters were evaluated: (1) the type of osteoarthritis of the involved hip and (2) the range of four radiographic indices of the contralateral hip: the sourcil inclination (weight-bearing surface), the acetabular angle, the Wiberg's center-edge angle, and the neck-shaft angle. Follow-up radiographs for the hips that remained OA-free were available for 10 to 35 years and for those that developed OA, at the time of initial symptoms, range 2 to 31 years. Logistic regression analysis showed that the presence of idiopathic OA in one hip had a statistically significant effect on the development of OA on the other hip (p<0.001). Minor deviations of radiographic indices of the contralateral hip is not a predictive factor for its outcome. When the radiographic indices are examined together with the pathology of the involved hip, only WBS was shown to have a significant effect to the development of OA and its type (p < 0.001). The following conclusions can be drawn from this study: 1. Patient with idiopathic OA of one hip is at increased risk of developing OA in the other hip. 2. The outcome of the other hip cannot be predicted only on the basis of the evaluation of its radiographic indices. 3. Among the different indices, WBS seems to have a strong influence toward the development of OA. (orig.)

  8. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  9. Fasilitas Pelatihan dan Pergelaran Seni Tari Hip Hop di Surabaya

    OpenAIRE

    Yanuar, Sandy

    2014-01-01

    Fasilitas Pelatihan dan Pergelaran Seni Tari Hip Hop di Surabaya merupakan fasilitas yang disediakan bagi semua penari Hip Hop di Surabaya untuk berlatih menari dan mempertunjukan tarian Hip Hop. Fasilitas ini tersedia bagi semua penari Hip Hop termasuk penari difable, mengingat kaum difable juga dapat menari Hip Hop. Namun karena di Surabaya belum memiliki fasilitas yang memadai bagi semua penari Hip Hop termasuk penari difable untuk menari dan memiliki tempat pertunjukan yang berkarakter Hi...

  10. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  11. Outcomes After Diagnostic Hip Injection.

    Science.gov (United States)

    Lynch, T Sean; Steinhaus, Michael E; Popkin, Charles A; Ahmad, Christopher S; Rosneck, James

    2016-08-01

    To provide a comprehensive review of outcomes associated with local anesthetic (LA) or LA and corticosteroid (CS) diagnostic hip injections, and how well response predicts subsequent operative success. A systematic review from database (PubMed, Medline, Scopus, Embase) inception to January 2015 for English-language articles reporting primary patient outcomes data was performed, excluding studies with >50% underlying osteoarthritis. Studies were assessed by 2 reviewers who collected pertinent data. Seven studies were included, reporting on a total 337 patients undergoing diagnostic hip injection. The mean age was 34.4 years, with 5 studies reporting 94 (35.2%) males and 173 (64.8%) females. One study examined the rate of pain relief with LA (92.5%); 2 CS studies reported relief on a scale from 0% to 100% (no to complete relief), ranging from 61% to 82.3%; and 3 studies used 10-point pain scales, with a CS study noting a pain score of 1.0, an LA study with a score of 3.03, and 1 study using either CS or LA scores of 3 to 5.6. Duration of pain relief was 9.8 (CS) and 2.35 days (LA). By pathology, greatest relief was achieved in acetabular chondral injury (93.3%) and least in cam impingement (81.6%), with clinical and imaging findings being unreliable predictors of relief. One study showed nonresponse to be a strong predictor of negative surgical outcome for femoroacetabular impingement. Diagnostic hip injections provide substantial pain relief for patients with various hip pathologies, with limited data to suggest greatest relief for those with chondral injury. Clinical and imaging findings are unreliable predictors of injection response, and nonresponse to injection is a strong negative predictor of surgical outcome. Future research should focus on elucidating differences by underlying pathology and predicting future operative success. Level IV, systematic review. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights

  12. Danish Hip Arthroscopy Registry (DHAR)

    DEFF Research Database (Denmark)

    Lund, Bent; Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten

    2017-01-01

    The Danish Hip Arthroscopy Registry (DHAR) was initiated in January 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the first registry based outcome data of a national population with radiological and clinical femoroacetabular impingement (FAI......) data from DHAR between January 2012 and November 2015 were extracted. Radiological pincer-type FAI was defined as LCE > 35° and cam FAI as alpha-angle > 55°. These data were combined with FAI surgical data such as osteochondroplasty and labral repair or resection. PROMs consisting of HAGOS, EQ-5 D...

  13. Vibration Control of a High-Speed Precision Servo Numerically Controlled Punching Press: Multidomain Simulation and Experiments

    Directory of Open Access Journals (Sweden)

    Teng Xu

    2017-01-01

    Full Text Available A three-degree-of-freedom mathematical vibration model of a high-speed punching press was developed in order to explore the vibration modes of the punching press. A multidomain model of the punching press was established to predict the kinematic state during different conditions, as well as the effects of load fluctuation on the motor speed. Experimental measurements of the acceleration of the punching press were carried out. The results comparison reveals that the multidomain model is consistent with the vibration model and the experimental measurements. Modal analysis and structure modification of the punching press were conducted. The foundation at the base of the punching press was improved against excess of vibration. The effects of the dimensions of the foundation on the vibration were discussed with the aid of the multidomain model. Finally, proper foundation design, able to reduce the vibration, was obtained.

  14. Hip strength and star excursion balance test deficits of patients with chronic ankle instability.

    Science.gov (United States)

    McCann, Ryan S; Crossett, Ian D; Terada, Masafumi; Kosik, Kyle B; Bolding, Brenn A; Gribble, Phillip A

    2017-11-01

    To examine isometric hip strength in those with and without CAI, and determine the degree of Star Excursion Balance Test (SEBT) variance explained by isometric hip strength. Single-blinded, cross-sectional, case-control study. Thirty individuals with CAI, 29 lateral ankle sprain (LAS) copers, and 26 healthy controls participated. We assessed dynamic postural control with the SEBT anterior (SEBT-ANT), posteromedial (SEBT-PM), and posterolateral (SEBT-PL) reaches, and isometric hip extension (EXT), abduction (ABD) and external rotation (ER) strength with hand-held dynamometry. The CAI and LAS coper groups' involved limbs and randomly selected limbs in controls were tested. Separate Kruskal-Wallis tests compared SEBT scores and isometric hip strength between groups. Backwards linear regression models determined the degree of SEBT variance explained by isometric hip strength. Statistical significance was set a priori at Phip strength compared to LAS copers and controls. Additionally, the CAI group's isometric hip strength significantly influenced dynamic postural control performance. Future CAI rehabilitation strategies should consider hip muscular strengthening to facilitate improvements in dynamic postural control. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. 28 CFR 540.64 - Press pools.

    Science.gov (United States)

    2010-07-01

    ... Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT CONTACT WITH PERSONS IN THE COMMUNITY Contact With News Media § 540.64 Press pools. (a) The Warden may establish a... shall notify all news media representatives who have requested interviews or visits that have not been...

  16. Law of the Student Press. Second Edition.

    Science.gov (United States)

    Student Press Law Center, Washington, DC.

    Noting dramatic changes in First Amendment protections for high school students and new legal issues facing college newspaper editors, this book describes in detail the legal rights and responsibilities of both the high school and college press. While the book is extensively footnoted, it intentionally avoids "legal-ese" and "brings…

  17. Press kit kicks off new branding.

    Science.gov (United States)

    Rees, Tom

    2004-01-01

    A smartly produced press kit resulted in unprecedented news coverage when Denver's Porter Adventist Hospital recently unveiled plans for an extensive 80 million dollars redevelopment. A news conference was held to announce this plan, along with the opening of the hospital's new emergency department. The overall effort is part of the new branding strategy of the 75-year-old hospital.

  18. The Moral Universes of Libertarian Press Theory.

    Science.gov (United States)

    Wuliger, Gregory T.

    1991-01-01

    Uses Kantian logic to analyze the statement of Libertarian press theory "Truth beats falsehood in a free marketplace of ideas" as a definition, an observation, and a universal truth. Notes three corresponding moral universes, with differing ethical obligations. Discusses strengths and weaknesses of each. Cautions media ethics analysts…

  19. Investigation of pressing of molybdenum powder compacts

    International Nuclear Information System (INIS)

    Mymrin, S.A.; Kuznetsov, V.Eh.; Yampol'skij, M.L.; Leonov, S.A.; Mikhridinov, R.M.; Korzukhin, V.A.

    1990-01-01

    Results of an experimental investigation into pressing of compacts of MCh type molybdenum powders using the industrial equipment are presented. To measure the density of powder molybdenum billets a radioisotopic density meter with cesium-137 is used as radioactive gamma radiation source. The dependence of the produced billet density on the specific compacting pressure at different values of the powder bulk density is ascertained

  20. Eye-Pressing by Visually Impaired Children.

    Science.gov (United States)

    Jan, James E.; And Others

    1983-01-01

    The nature of eye-pressing as a visual stimulation mannerism in children with severely impaired eyesight is examined, and a possible physiological explanation (that self-stimulation occurs when the demand of the brain for meaningful visual information is not met) is offered. (CL)

  1. Spontaneous pneumomediastinum after bench press training.

    Science.gov (United States)

    Nishino, Tomoya

    2017-04-01

    Spontaneous pneumomediastinum is often associated with asthma and mainly affects adolescent males with a tall, thin body habitus. A 17-year-old man complained of chest and pharyngeal pain after bench press training and spontaneous pneumomediastinum was diagnosed. It should be considered in the differential diagnosis of chest pain of uncertain cause.

  2. A Journalist's Guide to the Free Press.

    Science.gov (United States)

    Ingelhart, Louis

    1996-01-01

    Summarizes the content of the federal constitution and various state constitutions regarding freedom of the press. Examines certain borderline issues, including actions and expressions, pornography, defamation, libel, and copyrighted material. States that regulation of unprotected material must be reasonable, specific, and clear. Discusses what…

  3. Free Press in a Constitutional Democracy

    Science.gov (United States)

    Lucianek, Christine

    2014-01-01

    This article describes a lesson in which students will examine several views expressed by the founders to understand the context for including freedom of the press in the First Amendment. Students will be asked to think about the role that the news media and the need to be an informed citizen continue to play in our democracy. Students will…

  4. [Report from the Student Press Law Center.

    Science.gov (United States)

    Student Press Law Center, Washington, DC.

    The Student Press Law Center serves as a national clearinghouse to collect, analyze, and distribute information on the First Amendment rights of student journalists and journalism teachers and on violations of these rights in high schools and colleges. This report details information concerning current censorship incidents: the investigation by…

  5. When International Press Rights "Are" the News

    Science.gov (United States)

    Freedman, Eric

    2006-01-01

    In many countries, reporters and editors face criminal prosecution, censorship, self-censorship, exile, tax audits, loss of broadcast and publication licenses, loss of jobs, assault, and even assassination based on how they practice their profession. Press rights and human rights advocacy groups try to draw media and official attention to those…

  6. Trial access to Cambridge University Press ebooks

    CERN Multimedia

    CERN Library

    2011-01-01

    From 1 August till 31 October, CERN users are invited to enjoy a trial access to all Cambridge University Press electronic books: http://ebooks.cambridge.org/. Please don't hesitate to send feedback to library.desk@cern.ch.

  7. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    Science.gov (United States)

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Intermittent Nitrate Use and Risk of Hip Fracture

    Science.gov (United States)

    Misra, Devyani; Peloquin, Christine; Kiel, Douglas P.; Neogi, Tuhina; Lu, Na; Zhang, Yuqing

    2016-01-01

    Purpose Nitrates, commonly used anti-anginal medications, also have beneficial effect on bone remodeling and bone density, particularly with intermittent use. However, their effect on fracture risk is not clear. We examined the relation of short-acting nitrate use (proxy for intermittent use) to the risk of hip fracture in a large cohort of older adults with ischemic heart disease. Materials and Methods Participants ≥ 60 years old with ischemic heart disease and without history of hip fracture from The Health Improvement Network (THIN), an electronic medical records database in the UK, were included. The association of incident (new) use of short-acting nitrate formulations (nitroglycerin sublingual/spray/ointment or ISDN injection/sprays) with incident (new-onset) hip fracture risk was examined by plotting Kaplan-Maier curves and calculating Hazard ratios (HR) using Cox proportional hazards regression models. Competing risk by death was analyzed in separate analyses. Results Among 14, 451 pairs of matched nitrate users and non-users (mean age 72±7.6, 41% women for each cohort), 573 fractures occurred during follow up (257 nitrate users; 316 non-users). Hip fracture risk was 33% lower among short-acting nitrate users compared with non-users (HR=0.67, 95% CI 0.53–0.85, p=0.0008). Competing risk analysis by death did not change effect estimates. Conclusion In this large population-based cohort of older adults with ischemic heart disease, we found significant reduction in hip fracture risk with use of short-acting nitrates (intermittent use). Future studies are warranted given the potential for nitrates to be potent, inexpensive and readily available anti-osteoporotic agents. PMID:27720852

  9. Determinants of time to surgery for patients with hip fracture.

    Science.gov (United States)

    Zeltzer, Justin; Mitchell, Rebecca J; Toson, Barbara; Harris, Ian A; Close, Jacqueline

    2014-09-01

    Guidelines for hip fracture care suggest that patients with hip fracture should undergo surgery on the day of or day after admission to hospital. This study examined factors affecting time to surgery for hip fracture extracted from existing administrative datasets in New South Wales (NSW), Australia. A retrospective analysis of patients with hip fracture aged 65 years and over undergoing surgical intervention in NSW public hospitals between 1 July 2000 and 30 June 2011. A multinomial logistic model was used to identify factors impacting on time to surgery from 1 July 2006 to 30 June 2011. A total of 49,317 hip fracture procedures were recorded during 2000-2001 to 2010-2011. Sixty-four per cent of patients received operative treatment on the day of or day after admission. Co-morbidity, type of surgical procedure and day of presentation all impacted significantly on time to surgery. Fourteen per cent required an inter-hospital transfer prior to receiving operative intervention. Transferred patients were 2.6 (95% confidence interval (CI): 2.31-2.85) times more likely to wait 2-4 days and 3.2 times more likely to wait 5 or more days (95% CI: 2.77-3.76) for surgery compared with patients presenting to an operating hospital. Significant variation exists between hospitals in the time to surgery that is not solely explained by measures of case mix or geography. Opportunities exist to consider other factors contributing to this variation and to ensure timely access to surgical intervention in the future. © 2014 Royal Australasian College of Surgeons.

  10. TREATMENT OF NEUROLOGICAL CONGENITAL HIP LUXATION

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available Congenital hip luxation is a disorder which evolves in time. Teratological hip dislocation is a distinct form of hip luxation, which usually appears with other disorders. These hips are dislocated before birth. In this thesis we will try to elaborate a recovery program, through physical exercises, which will help us realize our treatment objectives: diminishing articular stiffness, increasing articular mobility, increasing muscle strength, recalibration of agonist and antagonist balances and reeducating gait. The specific objectives of the study consist of the particularization of the recovery programs based on age, illness stage (dysplasia or luxation and either surgical or non-surgical intervention. To show the importance of physiotherapy in gait rehabilitation of a child with hip dislocation we started from the hypothesis: using an adequate rehabilitation program after an individualized methodology, optimizes the functional recovery and ensures the gains of hip stability and the formation of an engram of gait as close as it could be to the normal one. We present a case of neurological congenital hip dislocation where the treatment initiated early is showing good results. Results obtained are significantly different and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient has better biomechanical results for the hip.

  11. Maximum potential preventive effect of hip protectors

    NARCIS (Netherlands)

    van Schoor, N.M.; Smit, J.H.; Bouter, L.M.; Veenings, B.; Asma, G.B.; Lips, P.T.A.M.

    2007-01-01

    OBJECTIVES: To estimate the maximum potential preventive effect of hip protectors in older persons living in the community or homes for the elderly. DESIGN: Observational cohort study. SETTING: Emergency departments in the Netherlands. PARTICIPANTS: Hip fracture patients aged 70 and older who

  12. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  13. CT and MRI of hip arthroplasty

    International Nuclear Information System (INIS)

    Cahir, J.G.; Toms, A.P.; Marshall, T.J.; Wimhurst, J.; Nolan, J.

    2007-01-01

    Plain films are the initial imaging method of choice for evaluation of hip arthroplasty. Recent advances in technology and imaging techniques have largely overcome the problems of beam hardening in computed tomography (CT) and magnetic susceptibility artefact in magnetic resonance imaging (MRI). CT and MRI have now become useful imaging techniques in the assessment of hip arthroplasty

  14. Pressure ulcer risk in hip fracture patients

    NARCIS (Netherlands)

    Houwing, R. H.; Rozendaal, M; Wouters-Wesseling, W; Buskens, E.; Keller, P; Haalboom, JRE

    Hip fracture patients have a high risk of pressure ulcers (PU). We followed 121 hip fracture patients for the development of pressure ulcers and evaluated a risk assessment tool for sensitivity and specificity. More than half of the patients presented with PU, mostly stage I. Risk factors for PU

  15. Total hip arthroplasty for giant cell tumour.

    Directory of Open Access Journals (Sweden)

    Kulkarni S

    1996-07-01

    Full Text Available A 32 month follow up of an uncommon case of a Giant Cell Tumour affecting the proximal end of femur is presented. Following a wide excision, the hip was reconstructed using Charnley type of low friction total hip arthroplasty. At a 32 month review, there was no recurrence and the function was good.

  16. Pertunjukan Teater Karo Hip Hop Kontemporer KAI

    Directory of Open Access Journals (Sweden)

    Silvia Anggreni Purba

    2013-11-01

    Pertunjukan Teater Karo Hip Hop Kontemporer KAI. The performance of Karo Theater collaborated with Hip Hop stems from a simple idea to collaborate Karo cultural traditions with popular culture. The performances can be enjoyed without having limitation on the language and culture. The process of combining two different cultures is a form of hybrid culture, and it may occur due to the globalization process. Through the process of deposition of the observations and strong impression, this performance is then brought into the form of Hip Hop as a preferred form which is energetic, personal and global. This performance is part of a modern tragedy with its destructive character which has explored the emotion and has presented it to the audiences. The exploration of Karo cultural tradition and Hip Hop dance as a language of symbols is able to reinforce words. The movement is not revealed by the verbal phrase but is presented through the movement of Hip Hop dance. The interpretation of the legend and texts into movement is carried out through the training process at the laboratory as a searching process and experiment, and afterward can be realized by considering the basic elements of Hip Hop, Karo cultural elements and performance. Karo Hip Hop Theatre is expected to become a preferred aesthetic form of a modern theater without losing its tradition form. Keyword: a contemporary Karo theater, Hip Hop, hybrid culture.

  17. Hip-hop and urban studies

    NARCIS (Netherlands)

    Jaffe, R.

    2014-01-01

    How can urban studies research engage fruitfully with hip-hop? This contribution responds to the essays by David Beer and Martin Lamotte on ‘street music’, urban ethnography and ghettoized communities. It discusses how a social science engagement with hip-hop texts might differ from cultural studies

  18. Enhancing the CuCrZr/316L HIP-joint by Ni electroplating

    Energy Technology Data Exchange (ETDEWEB)

    Wei, R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Zhao, S.X., E-mail: sxzhao@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Science, Lanzhou, 730000 (China); Dong, H.; Che, H.Y. [Advanced Technology and Materials Co. Ltd., Beijing, 100081 (China); Li, Q.; Wang, W.J.; Wang, J.C.; Wang, X.L.; Sun, Z.X. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Luo, G.-N. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Hefei Center for Physical Science and Technology, Hefei, 230022 (China); Hefei Science Center of Chinese Academy of Sciences, Hefei, 230027 (China)

    2017-04-15

    Highlights: • The quality of CuCrZr/316L HIP-joint can be enhanced by nickel electroplating on CuCrZr and 316L. • Nickel layer can prevent the occurrence of nickel-poor region in 316L and protect CuCrZr from oxidation. • A Charpy Impact Value as high as 111.5 ± 3.3 J/cm{sup 2} can be obtained by HIP at 980 °C, 140 MPa for 2 h. • At high temperature, CuCrZr is easily oxidized even in the situation of a high vacuum degree of 2 × 10{sup −5} Pa. - Abstract: The quality of CuCrZr/316L joint is crucial for the safety of ITER hypervapotron cooling structure and hot isostatic pressing (HIP) is an important bonding technique for this structure. In this paper, the authors present a finding that the CuCrZr/316L HIP-joint can be enhanced by nickel electroplating on 316L and CuCrZr. A Charpy Impact Value as high as 111.5 ± 3.3 J/cm{sup 2}, which is more than two times the value in a published article, is obtained. The influence of nickel electroplating is twofold: (1) it can prevent the occurrence of nickel-poor region in 316L and the formation of ferrite; (2) it can protect CuCrZr from oxidation during the heating stage of HIP. However, tensile test is not as effective as Charpy Impact Test in characterizing the bonding quality of the CuCrZr/316L HIP-joint. The surface treatment employed in this study is amenable to batch-scale industrial manufacturing at low cost.

  19. Dairy product consumption and risk of hip fracture: a systematic review and meta-analysis

    OpenAIRE

    Bian, Shanshan; Hu, Jingmin; Zhang, Kai; Wang, Yunguo; Yu, Miaohui; Ma, Jie

    2018-01-01

    Background Dairy product consumption may affect the risk of hip fracture, but previous studies have reported inconsistent findings. The primary aim of our meta-analysis was to examine and quantify the potential association of dairy product consumption with risk of hip fracture. Methods We searched the databases of PubMed and EMBASE for relevant articles from their inception through April 17, 2017. The final analysis included 10 cohort studies and 8 case-control studies. Random-effects models ...

  20. Avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Lang, P.; Genant, H.K.; Lindquist, T.; Chafetz, N.; Steiger, P.; Sanny, J.; Rhodes, M.L.; Rothman, S.L.G.; Delamarter, R.; Kilgus, D.

    1988-01-01

    T1-weighted (repetition time [TR] = 450 msec, echo time [TE] = 20 msec), T2-weighted (TR = 1,800 msec, TE = 20 and 80 msec), and T2*-weighted gradient-echo gradient recalled acquisition in a steady state, TR = 70 msec, TE = 30 msec, theta = 15 0 ) MR images (General Electric Signa, 1.5 T) were generated in 11 patients with avascular necrosis of the hip. Three-dimensional MR image reconstruction was performed on an independent imaging system (IIS, Dimensional Medicine Inc). Pelvic and femoral bone contours were computed based on either the T1-weighted or the T2*-weighted images. Three-dimensional displays of necrotic zones and areas of granulation tissue were computed on the basis of the T2-weighted images. The tissues were simultaneously displayed in the three-dimensional images using different colors and transparencies. The three-dimensional MR images generated demonstrated the extent of the necrotic zone and adjacent granulation tissue and their position relative to the weight-bearing surface. They may soon prove to be useful in preoperative planning and intraoperative localization of complex surgical interventions in avascular necrosis of the hip

  1. Hip fracture in hospitalized medical patients

    Directory of Open Access Journals (Sweden)

    Zapatero Antonio

    2013-01-01

    Full Text Available Abstract Background The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. Methods We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization. Outcome measures included rates of in-hospital fractures, length of stay and cost. Results A total of 1127 (0.057% admittances were coded with an in-hospital hip fracture. In hospital mortality rate was 27.9% vs 9.4%; p  Conclusions In-hospital hip fracture notably increased mortality during hospitalization, doubling the mean length of stay and mean cost of admission. These are reasons enough to stress the importance of designing and applying multidisciplinary plans focused on reducing the incidence of hip fractures in hospitalized patients.

  2. [The hip joint in neuromuscular disorders].

    Science.gov (United States)

    Strobl, W M

    2009-07-01

    Physiologic motor and biomechanical parameters are prerequisites for normal hip development and hip function. Disorders of muscle activity and lack of weight bearing due to neuromuscular diseases may cause clinical symptoms such as an unstable hip or reduced range of motion. Disability and handicap because of pain, hip dislocation, osteoarthritis, gait disorders, or problems in seating and positioning are dependent on the severity of the disease, the time of occurrence, and the means of prevention and treatment. Preservation of pain-free and stable hip joints should be gained by balancing muscular forces and by preventing progressive dislocation. Most important is the exact indication of therapeutic options such as movement and standing therapy as well as drugs and surgery.

  3. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  4. Hip strength and range of motion

    DEFF Research Database (Denmark)

    Mosler, Andrea B.; Crossley, Kay M.; Thorborg, Kristian

    2017-01-01

    Objectives To determine the normal profiles for hip strength and range of motion (ROM) in a professional football league in Qatar, and examine the effect of leg dominance, age, past history of injury, and ethnicity on these profiles. Design Cross-sectional cohort study. Methods Participants...... values are documented for hip strength and range of motion that can be used as reference profiles in the clinical assessment, screening, and management of professional football players. Leg dominance, recent past injury history and ethnicity do not need to be accounted for when using these profiles...... included 394 asymptomatic, male professional football players, aged 18–40 years. Strength was measured using a hand held dynamometer with an eccentric test in side-lying for hip adduction and abduction, and the squeeze test in supine with 45° hip flexion. Range of motion measures included: hip internal...

  5. Pre-fracture individual characteristics associated with high total health care costs after hip fracture.

    Science.gov (United States)

    Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E

    2017-03-01

    Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.

  6. Copper produced from powder by HIP to encapsulate nuclear fuel elements

    International Nuclear Information System (INIS)

    Ekbom, L.B.; Bogegaard, S.

    1989-02-01

    In the Swedish nuclear waste mangement program, nuclear fuel elements are proposed to be encapsulated in copper canisters. To fill the space between the fuel elements two methods have been proposed. Originally lead was proposed to be cast into the canister. According to a second method the space between the fuel rods is filled with copper powder and hot isostatic pressed (HIP) to seal the canister lid and to densify the powder to homogenous copper. This latter method has the advantage that each fuel rod is individually encapsulated in a very corrosion resistant material. This investigation was performed to find out to what extent pure copper powder can be hot isosatic pressed to full density and to achieve properties comparable to that of the oxygen free high conductivity (OFHC) copper of the canister. OFHC copper was molten under helium gas protection and atomized to a fine spherical powder in a pilot plant. The powder was transfered to a glove box with an argon atmosphere. The powder was filled into a steel container, which was evacuated and sealed. HIP was done at 550 degree C and 200 MPa for one hour. The resulting copper was found to have a good ductility and mechanical properties comparable to that of ordinary copper. The constant strainrate stress corrosion test used to test the canister copper showed that the HIP-ed copper has the same good properties as OFHC copper. (authors)

  7. Radioactive waste immobilization in protective ceramic forms by the HIP method at high pressures

    International Nuclear Information System (INIS)

    Sayenko, S.Yu.; Kantsedal, V.P.; Tarasov, R.V.; Starchenko, V.A.; Lyubtsev, R.I.

    1993-01-01

    Intense research activities have been carried out in recent years at the Kharkov Institute of Physics and Technology (KIPT) to develop the method of hot isostatic pressing (HIP) for immobilizing radioactive (primarily, high-level) wastes. With this method, the radioactive material is immobilized in a matrix under the simultaneous action of high pressures (up to 6,000 atm) and appropriate temperatures. The process has 2 variants: (1) radioactive wastes are treated as powders of oxides resulting from calcination during chemical treatment of spent fuel. In this case the radioactive material enters into the crystalline structure of the immobilized matrix or is distributed in the matrix as a homogeneous mixture; (2) protective barrier layers are pressed on spent fuel rods or their pieces as radioactive wastes, by the HIP method (fuel rod encapsulation in a protective form). Based on numerous results from various studies, the authors suggest that various ceramic compositions should be used as protective materials. Here the authors report two trends of their investigations: (1) development of ecologically clean process equipments for radioactive waste treatment by the HIP method; (2) manufacture of promising protective ceramic compositions and investigation of their physico-mechanical properties

  8. Verification of the Robin and Graham classification system of hip disease in cerebral palsy using three-dimensional computed tomography.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Akiyama, Keisuke; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2011-12-01

    We evaluated the validity of the Robin and Graham classification system of hip disease in cerebral palsy (CP) using three-dimensional computed tomography in young people with CP. A total of 91 hips in 91 consecutive children with bilateral spastic CP (57 males, 34 females; nine classified at Gross Motor Function Classification System level II, 42 at level III, 32 at level IV, and eight at level V; mean age 5 y 2 mo, SD 11 mo; range 2-6 y) were investigated retrospectively using anteroposterior plain radiographs and three-dimensional computed tomography (3D-CT) of the hip. The migration percentage was calculated on plain radiographs and all participants were classified into four groups according to migration percentage: grade II, migration percentage ≥ 10% but ≤ 15%, (four hips), grade III, migration percentage >15% but ≤ 30%, (20 hips); grade IV, migration percentage >30% but <100%, (63 hips); and grade V, migration percentage ≥ 100%, (four hips). The lateral opening angle and the sagittal inclination angle of the acetabulum, the neck-shaft angle, and the femoral anteversion of the femur were measured on 3D-CT. The three-dimensional quantitative evaluation indicated that there were significant differences in the lateral opening angle and the neck-shaft angle between the four groups (Kruskal-Wallis test, p ≤ 0.001). This three-dimensional evaluation supports the validation of the Robin and Graham classification system for hip disease in 2- to 7-year-olds with CP. © The Authors. Developmental Medicine & Child Neurology © 2011 Mac Keith Press.

  9. Machine Learning Principles Can Improve Hip Fracture Prediction

    DEFF Research Database (Denmark)

    Kruse, Christian; Eiken, Pia; Vestergaard, Peter

    2017-01-01

    Apply machine learning principles to predict hip fractures and estimate predictor importance in Dual-energy X-ray absorptiometry (DXA)-scanned men and women. Dual-energy X-ray absorptiometry data from two Danish regions between 1996 and 2006 were combined with national Danish patient data.......89 [0.82; 0.95], but with poor calibration in higher probabilities. A ten predictor subset (BMD, biochemical cholesterol and liver function tests, penicillin use and osteoarthritis diagnoses) achieved a test AUC of 0.86 [0.78; 0.94] using an “xgbTree” model. Machine learning can improve hip fracture...... prediction beyond logistic regression using ensemble models. Compiling data from international cohorts of longer follow-up and performing similar machine learning procedures has the potential to further improve discrimination and calibration....

  10. Outcomes of Hip Arthroscopy in Competitive Athletes.

    Science.gov (United States)

    Perets, Itay; Hartigan, David E; Chaharbakhshi, Edwin O; Ashberg, Lyall; Ortiz-Declet, Victor; Domb, Benjamin G

    2017-08-01

    To evaluate the minimum 2-year postoperative clinical outcomes and the rate of return to sports in athletes who underwent capsular plication for the treatment of ligamentous laxity and/or borderline dysplasia during hip arthroscopy for the treatment of femoroacetabular impingement and labral pathology. Since 2008, data were prospectively collected on patients who underwent hip arthroscopy for the treatment of femoroacetabular impingement and/or labral tears. Inclusion criteria were as follows: athlete at the high school, collegiate, or professional levels preoperatively, underwent capsular plication, and preoperatively recorded patient-reported outcome scores including modified Harris hip score (mHHS), nonarthritic athletic hip score (NAHS), hip outcome score-sports-specific subscale (HOS-SSS), and visual analog scale (VAS). Exclusion criteria were as follows: 1, and previous hip conditions. Sports activity and competitive levels were collected at a minimum of 2 years postoperatively. Fifty-one hips (49 patients) met the inclusion criteria, and 41 hips (39 patients) had minimum 2-year follow-up (80.4% follow-up). Mean mHHS increased from 67.1 preoperatively to 83.5 (P arthroscopies allowed the patients to return to sports at follow-up. Thirty-four (82.9%) hip arthroscopies allowed the patients to maintain their competitive physical abilities at follow-up. Patient-reported outcomes and VAS in athletes significantly improved at a minimum of 2 years after capsular plication as a part of hip arthroscopy addressing varying pathologies. In addition, most patients returned to sports at similar or higher competitive levels. These results suggest that capsular plication is a favorable treatment option in athletes with ligamentous laxity and/or borderline dysplasia. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. The LNG industry in 2011. Press revue

    International Nuclear Information System (INIS)

    2012-05-01

    The outlook of the LNG industry in 2011 is presented as a revue of press articles: The role of LNG as a flexible and secure energy source as well as the prompt response to provide back-up through additional supplies and cargo diversions to compensate for the sudden loss of nuclear capacity in Japan - with sellers exercising due price restraint in view of the human tragedy - has been a credit to the industry. The increase in production capacity in 2009 and 2010, in particular from Qatar, had permitted the necessary buffer to cope much better with the demand surge than during past disruptions (such as the aftermath of the Chuetsu earthquake in late 2007). Undoubtedly, the marked shift over the last decade in the industry's prevailing business model towards global trade, destination flexibility and portfolio play has also facilitated the rapid response. As the total volume of LNG trade is very much determined by the availability of supply, 2011 has seen a growth of 9.4% over 2010, mainly as a result of the full availability of the six Qatar mega-trains over the past year. On the demand side the two traditional basins have shown very contrasting trends: 15% higher LNG off-take in Asia (the five major markets all increasing between 37.4% and 8.9%), versus a 1.7% decrease in the Atlantic Basin. Cargo diversions and an increasing number of reloads have boosted the exports from the Atlantic Basin to Asia in 2011 to more than 14 million tons (equivalent to more than 200 large size cargoes). Remarkable is also the fast growth in new markets in Latin America and in the Middle East - albeit from a small base - with counter-seasonal but varying demand, offering attractive arbitrage opportunities to portfolio play. Not surprising then that 2011 has seen another hike in spot and short-term trade, not just in absolute terms but also as a percentage of total trade (50% over 2010, 25.4% of total trade). The outlook for LNG is strong and its global demand prospects further

  12. Methodological comparison of marginal structural model, time-varying Cox regression, and propensity score methods : the example of antidepressant use and the risk of hip fracture

    NARCIS (Netherlands)

    Ali, M Sanni; Groenwold, Rolf H H; Belitser, Svetlana V; Souverein, Patrick C; Martín, Elisa; Gatto, Nicolle M; Huerta, Consuelo; Gardarsdottir, Helga; Roes, Kit C B; Hoes, Arno W; de Boer, Antonius; Klungel, Olaf H

    2016-01-01

    BACKGROUND: Observational studies including time-varying treatments are prone to confounding. We compared time-varying Cox regression analysis, propensity score (PS) methods, and marginal structural models (MSMs) in a study of antidepressant [selective serotonin reuptake inhibitors (SSRIs)] use and

  13. Graphic Arts: Book Three. The Press and Related Processes.

    Science.gov (United States)

    Farajollahi, Karim; And Others

    The third of a three-volume set of instructional materials for a graphic arts course, this manual consists of nine instructional units dealing with presses and related processes. Covered in the units are basic press fundamentals, offset press systems, offset press operating procedures, offset inks and dampening chemistry, preventive maintenance…

  14. On the permanent hip-stabilizing effect of atmospheric pressure.

    Science.gov (United States)

    Prietzel, Torsten; Hammer, Niels; Schleifenbaum, Stefan; Kaßebaum, Eric; Farag, Mohamed; von Salis-Soglio, Georg

    2014-08-22

    Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Consolidation of W–Ta composites: Hot isostatic pressing and spark and pulse plasma sintering

    Energy Technology Data Exchange (ETDEWEB)

    Dias, M., E-mail: marta.dias@itn.pt [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Guerreiro, F. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Correia, J.B. [LNEG, Laboratório Nacional de Energia e Geologia, Estrada do Paço do Lumiar, 1649-038 Lisboa (Portugal); Galatanu, A. [National Institute of Materials Physics, Atomistilor 105 bis Bucharest-Magurele, 077125 Ilfov (Romania); Rosiński, M. [Warsaw University of Technology, Faculty of Materials Science and Engineering, Warsaw (Poland); Monge, M.A.; Munoz, A. [Departamento de Física, Univerdidad Carlos III de Madrid, Avd. de la Universidad 30, 28911 Madrid (Spain); Alves, E. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Carvalho, P.A. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); CeFEMA, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal)

    2015-10-15

    Highlights: • Consolidation of W–Ta composites using three techniques: HIP, SPS and PPS. • Comparison of consolidation methods in terms of W–Ta interdiffusion and densification. • Microstructure analysis in terms of oxides formation. - Abstract: Composites consisting of tantalum fiber/powder dispersed in a nanostructured W matrix have been consolidated by spark and pulse plasma sintering as well as by hot isostatic pressing. The microstructural observations revealed that the tungsten–tantalum fiber composites consolidated by hot isostatic pressing and pulse plasma sintering presented a continuous layer of Ta{sub 2}O{sub 5} phase at the W/Ta interfaces, while the samples consolidated by spark plasma sintering evidenced a Ta + Ta{sub 2}O{sub 5} eutectic mixture due to the higher temperature of this consolidation process. Similar results have been obtained for the tungsten–tantalum powder composites. A (W, Ta) solid solution was detected around the prior nanostructured W particles in tungsten–tantalum powder composites consolidated by spark and pulse plasma sintering. Higher densifications were obtained for composites consolidated by hot isostatic pressing and pulse plasma sintering.

  16. Comparative Thermal Aging Effects on PM-HIP and Forged Inconel 690

    Science.gov (United States)

    Bullens, Alexander L.; Bautista, Esteban; Jaye, Elizabeth H.; Vas, Nathaniel L.; Cain, Nathan B.; Mao, Keyou; Gandy, David W.; Wharry, Janelle P.

    2018-03-01

    This study compares thermal aging effects in Inconel 690 (IN690) produced by forging and powder metallurgy with hot isostatic pressing (PM-HIP). Isothermal aging is carried out over 400-800°C for up to 1000 h and then metallography and nanoindentation are utilized to relate grain microstructure with hardness and yield strength. The PM-HIP IN690 maintains a constant grain size through all aging conditions, while the forged IN690 exhibits limited grain growth at the highest aging temperature and longest aging time. The PM-HIP IN690 exhibits comparable mechanical integrity as the forged material throughout aging: hardness and yield strength are unchanged with 100 h aging, but increase after 1000 h aging at all temperatures. In both the PM-HIP and forged IN690, the Hall-Petch relationship for Ni-based superalloys predicts yield strength for 0-100 h aged specimens, but underestimates yield strength in the 1000 h aged specimens because of thermally induced precipitation.

  17. Fabrication of TBMs cooling structures demonstrators using additive manufacturing (AM) technology and HIP

    Energy Technology Data Exchange (ETDEWEB)

    Ordás, Nerea, E-mail: nordas@ceit.es [CEIT-IK4 and Tecnun (University of Navarra), Donostia-San Sebastián (Spain); Ardila, Luis Carlos [IK4-LORTEK Joining Research Institute, Ordizia (Spain); Iturriza, Iñigo [CEIT-IK4 and Tecnun (University of Navarra), Donostia-San Sebastián (Spain); Garcianda, Fermín; Álvarez, Pedro [IK4-LORTEK Joining Research Institute, Ordizia (Spain); García-Rosales, Carmen [CEIT-IK4 and Tecnun (University of Navarra), Donostia-San Sebastián (Spain)

    2015-10-15

    Highlights: • TBM geometrically relevant component components were obtained by addtive manufacturing. • P91, a ferritic–martensitic steel metallurgically similar to EUROFER was used. • Dense core walls were obtained by SLM, though contour of cooling channel walls are slightly porous. • HIP after SLM is effective in removing the porosity and homogenizing the microstructure. • After HIP + normalizing + tempering mechanical behavior is similar to P91 as received. - Abstract: Several mock-ups, each of them consisting of six rectangular channels with dimensions according to the EU Test Blanket Modules (TBMs) specifications, were manufactured by selective laser melting (SLM) technology using P91, a ferritic–martensitic 9%Cr–1%Mo–V steel with a metallurgical behavior similar to EUROFER, the reference structural material for DEMO blanket concepts. SLM parameters led to an as-built density of 99.35% Theoretical Density (TD) that increased up to 99.74% after hot isostatic pressing (HIP). Dimensional control showed that the differences between the original design and the component are below 100 μm. By the appropriate selection of normalization and tempering parameters it was possible to obtain a material fulfilling P91 specification. The microstructure was investigated after SLM, HIP and normalizing and tempering treatments. In all cases, it consisted of thin martensitic laths. Subsize tensile samples were extracted from the mock-ups to measure the mechanical tensile properties after each step of the manufacturing process. The effect of thermal treatments on hardness was also evaluated.

  18. Effect of HIP Combined with RHT Process on Creep Damage of DZ125 Superalloy

    Directory of Open Access Journals (Sweden)

    WANG Tian-you

    2017-02-01

    Full Text Available Four different processes of hot isostatic pressing (HIP combined with rejuvenation heat treatments (RHT were adopted to reveal the microstructural evolution of creep damaged DZ125 specimens, finally the mechanical properties were evaluated.The results show that both γ' precipitate degeneration and creep cavities for the creep damaged DZ125 superalloy are found after the pre-endurance damage test.However, the carbided compositions from MC type to M23C6 type or M6C type has not been observed for DZ125.In addition, it is found that the HIP temperature play a dominant role in the cavity healing process for the damaged specimens. The concentrically oriented γ' rafting structure and the incipient melting are observed at 1200℃ and 1250℃ respectively.Meanwhile, it is found that the appropriate HIP schedule adopted can effectively avoid the internal recrystallization for the directionally solidified nickel-based superalloy DZ125. The appropriate HIP schedule combined with RHT process can successfully restore the microstructure induced by creep damage and recover the degraded micro-hardness to the original one, in addition improve the creep rupture life.

  19. The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.

    Science.gov (United States)

    Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A

    2016-03-01

    To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing

  20. Bench press exercise: the key points.

    Science.gov (United States)

    Padulo, J; Laffaye, G; Chaouachi, A; Chamari, K

    2015-06-01

    The bench press exercise (BPE) is receiving increasing interest as a field testing, training/therapeutic modality to improve neuromuscular performance or to increase bone mass density. Several studies have been performed using BPE as a standard for increasing upper-limb strength. For this purpose, the position of the bar, the loads, the sets, the number of repetitions, the recovery time in-between sets, the movement speed, the muscular work and the use of the determination of the one repetition maximum (1-RM) are the classical tools investigated in the literature that have been shown to affect the BPE effect on neuromuscular. The goal of the present short review is to make a picture of the current knowledge on the bench press exercise, which could be very helpful for a better understanding of this standard movement and its effects. Based on the related literature, several recommendations on these key points are presented here.

  1. Reducing VOC Press Emission from OSB Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Gary D. McGinnis; Laura S. WIlliams; Amy E. Monte; Jagdish Rughani: Brett A. Niemi; Thomas M. Flicker

    2001-12-31

    Current regulations require industry to meet air emission standards with regard to particulates, volatile organic compounds (VOCs), hazardous air pollutants (HAPs) and other gases. One of many industries that will be affected by the new regulations is the wood composites industry. This industry generates VOCs, HAPs, and particulates mainly during the drying and pressing of wood. Current air treatment technologies for the industry are expensive to install and operate. As regulations become more stringent, treatment technologies will need to become more efficient and cost effective. The overall objective of this study is to evaluate the use of process conditions and chemical additives to reduce VOC/HAPs in air emitted from presses and dryers during the production of oriented strand board.

  2. Method for hot pressing beryllium oxide articles

    Science.gov (United States)

    Ballard, Ambrose H.; Godfrey, Jr., Thomas G.; Mowery, Erb H.

    1988-01-01

    The hot pressing of beryllium oxide powder into high density compacts with little or no density gradients is achieved by employing a homogeneous blend of beryllium oxide powder with a lithium oxide sintering agent. The lithium oxide sintering agent is uniformly dispersed throughout the beryllium oxide powder by mixing lithium hydroxide in an aqueous solution with beryllium oxide powder. The lithium hydroxide is converted in situ to lithium carbonate by contacting or flooding the beryllium oxide-lithium hydroxide blend with a stream of carbon dioxide. The lithium carbonate is converted to lithium oxide while remaining fixed to the beryllium oxide particles during the hot pressing step to assure uniform density throughout the compact.

  3. Freedom of the Press – two concepts

    Directory of Open Access Journals (Sweden)

    Markus Meckl

    2015-03-01

    Full Text Available In 1644 the debate for freedom of expression started in modern times thanks to John Milton’s Areopagitica, where he still argued about God in order to justify his quest for freedom. With the enlightenment God lost his unifying role for society and could no longer serve as justification. Two arguments were brought then forward to justify freedom of the press: One by the continental movement of the enlightenment; the other from within the movement of utilitarianism, and most influentially by John Stuart Mill. Both underlined the importance of truth; however, they differed in their understanding on what truth was good for. This difference in their arguments had a lasting impact on the debate on the limits of freedom of the press.

  4. A comparative study of the mechanical properties and the behavior of carbon and boron in stainless steel cladding tubes fabricated by PM HIP and traditional technologies

    Science.gov (United States)

    Shulga, A. V.

    2013-03-01

    The ring tensile test method was optimized and successfully used to obtain precise data for specimens of the cladding tubes of AISI type 316 austenitic stainless steels and ferritic-martensitic stainless steel. The positive modifications in the tensile properties of the stainless steel cladding tubes fabricated by powder metallurgy and hot isostatic pressing of melt atomized powders (PM HIP) when compared with the cladding tubes produced by traditional technology were found. Presently, PM HIP is also used in the fabrication of oxide dispersion strengthened (ODS) ferritic-martensitic steels. The high degree of homogeneity of the distribution of carbon and boron as well the high dispersivity of the phase-structure elements in the specimens manufactured via PM HIP were determined by direct autoradiography methods. These results correlate well with the increase of the tensile properties of the specimens produced by PM HIP technology.

  5. Optimization of HIP bonding conditions for ITER shielding blanket/first wall made from austenitic stainless steel and dispersion strengthened copper alloy

    International Nuclear Information System (INIS)

    Sato, S.; Hatano, T.; Kuroda, T.; Furuya, K.; Hara, S.; Enoeda, M.; Takatsu, H.

    1998-01-01

    Optimum bonding conditions were studied on the hot isostatic pressing (HIP) bonded joints of type 316L austenitic stainless steel and dispersion strengthened copper alloy (DSCu) for application to the ITER shielding blanket / first wall. HIP bonded joints were fabricated at temperatures in a 980-1050 C range, and a series of mechanical tests and metallurgical observations were conducted on the joints. Also, bondability of two grades of DSCu (Glidcop Al-25 trademark and Al-15 trademark ) with SS316L was examined in terms of mechanical properties of the HIP bonded joints. From those studies it was concluded that the HIP temperature of 1050 C was an optimal condition for obtaining higher ductility, impact values and fatigue strength. Also, SS316L/Al-15 joints showed better results in terms of ductility and impact values compared with SS316L/Al-25 joints. (orig.)

  6. [Application of computer-aided osteotomy template design in treatment of developmental dysplasia of the hip with steel osteotomy].

    Science.gov (United States)

    Tong, Kuang; Zhang, Yuanzhi; Zhang, Sheng; Yu, Bin

    2013-06-01

    To provide an accurate method for osteotomy in the treatment of developmental dysplasia of the hip with steel osteotomy by three-dimensional reconstruction and Reverse Engineering technique. Between January 2011 and December 2012, 13 children with developmental dysplasia of the hip underwent steel osteotomy. 3D CT scan pelvic images were obtained and transferred via a DICOM network into a computer workstation to construct 3D models of the hip using Materialise Mimics 14.1 software in STL format. These models were imported into Imageware 12.0 software for steel osteotomy simulation until a stable hip was attained in the anatomical position for dislocation or subluxation of the hip in older children. The osteotomy navigational templates were designed according to the anatomical features after a stable hip was reconstructed. These navigational templates were manufactured using a rapid prototyping technique. The reconstruction hips in these children show good matching property and acetabulum cover. The computer-aided design of osteotomy template provides personalized and accurate solutions in the treatment of developmental dysplasia of the hip with steel osteotomy in older children.

  7. Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    Vasileios Sakellariou

    2014-09-01

    Full Text Available Developmental dysplasia of the hip (DDH or congenital hip dysplasia (CDH is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DDH, 32.5 years for low dislocation, 31.2 years for high dislocation with a false acetabulum, and 46.4 years for high dislocation without a false acetabulum. Thorough understanding of the bony and soft tissue deformities induced by dysplasia is crucial for the success of total hip arthroplasty. It is important to evaluate the existing acetabular deformity three-dimensionally, and customize the correction in accordance with the quantity and location of ace tabular deficiencies. Acetabular reconstruction in patients with DDH is hallenging. Interpretation of published data is difficult and should be done with caution because most series include patients with different types of hip disease. In general, the complication rate associated with THA is higher in patients with hip dysplasia than it is in patients with osteoarthritis. Overall, clinical and functional outcomes following THA in patients hip dysplasia (DDH differ from those treated for primary hip osteoarthritis, possibly due to the lower age and level of activity. Although function scores decline with age, the scores for pain and range of motion presented with a statistically significant improvement in the long-term.

  8. Hip instability: a review of hip dysplasia and other contributing factors

    Science.gov (United States)

    Kraeutler, Matthew J.; Garabekyan, Tigran; Pascual-Garrido, Cecilia; Mei-Dan, Omer

    2016-01-01

    Summary Background Hip instability has classically been associated with developmental dysplasia of the hip (DDH) in newborns and children. However, numerous factors may contribute to hip instability in children, adolescents, and adults. Purpose This review aims to concisely present the literature on hip instability in patients of all ages in order to guide health care professionals in the appropriate diagnosis and treatment of the various disorders which may contribute to an unstable hip. Methods We reviewed the literature on the diagnosis and surgical management of hip dysplasia and other causes of hip instability. Conclusions Multiple intra- and extra-articular variables may contribute to hip instability, including acetabular bony coverage, femoral torsion, femoroacetabular impingement, and soft tissue laxity. Physical examination and advanced imaging studies are essential to accurately diagnose the pathology contributing to a patient’s unstable hip. Conservative management, including activity modification and physical therapy, may be used as a first-line treatment in patients with intra-articular hip pathology. Patients who continue to experience symptoms of pain or instability should proceed with arthroscopic or open surgical treatment aimed at correcting the underlying pathology. Level of evidence V. PMID:28066739

  9. Analysis of hip perfusion at early and reversible stages of aseptic hip necrosis

    International Nuclear Information System (INIS)

    Predic, P.; Dodig, D.; Karner, I.

    2002-01-01

    Aim: A proper early diagnosis of aseptic hip necrosis is very important for further therapy.Since there has always been a question of the amount of perfusion in hips at different stages of aseptic hip necrosis we tried to impartially examine the perfusion in hips at early and reversible stages of aseptic hip necrosis. Material and Methods:Study included 143 patients with aseptic hip necrosis.The 550-740 MBq of Tc-99m-DPD were on bolus injected.All patients were subjected to 3-phase scintigraphy of hips and quantitative calculation of relative perfusion in the artery phase (3T) at early and repeated at reversible stages of aseptic hip necrosis. Results: At the early stage of aseptic hip necrosis the obtained 3T was decreased from 0.94-0.69 (3T=0.80).Scintigrams showed a moderate increase or diffuse accumulation. At the reversible stages we obtained 3T decreased from 0.92-0.71 (3T=0.79) thus evidencing hypoperfusion.Scintigrams showed an diffuse increased accumulation. Conclusion: With the aseptic hip necrosis quantitative analysis of perfusion in the artery phase-3T indicates that the perfusion is decreased at all stages of the process which however shows a significantly falling trend with the progress of the disease

  10. Assessment of the hip reduction angle for predicting osteoarthritis of the hip in the Labrador Retriever.

    Science.gov (United States)

    Corfield, G S; Read, R A; Eastley, K A; Richardson, J L; Robertson, I D; Day, R

    2007-06-01

    Hip palpation has been used to provide semiquantitative information regarding passive joint laxity and susceptibility to hip dysplasia. The purpose of this study was to: (1) evaluate the intra- and inter-examiner repeatability of the hip reduction angle measured at 4 months of age by three examiners using manual goniometry and an electromagnetic tracking system; (2) compare the hip reduction angle measured with manual goniometry to the hip reduction angle measured with the electromagnetic tracking system; and (3) evaluate the hip reduction angle, distraction index and Ortolani manoeuvre at 4 months of age as predictors of the development of hip osteoarthritis at 12 months of age in 11 Labrador Retriever dogs. Intra- and inter-examiner repeatability was demonstrated for both the manual and electromagnetic goniometric measurement of the hip reduction angle (coefficient of variation goniometry was moderately correlated to the hip reduction angle measured by the electromagnetic tracking system (r = 0.603, P goniometry was a poor predictor of osteoarthritis at 12 months of age (r = 0.231, P < 0.062, and r = 0.321, P < 0.01). The distraction index was moderately correlated with the development of osteoarthritis by 12 months of age (r = 0.493, P < 0.0000). The Ortolani sign was sensitive (100%) but not specific (41%) for the development of osteoarthritis at 12 months of age. The hip reduction angle did not further quantify the Ortolani manoeuvre as a predictor of osteoarthritis in Labrador Retrievers.

  11. Analysis of Institutional Press Releases and its Visibility in the Press

    Directory of Open Access Journals (Sweden)

    José Antonio Alcoceba-Hernando, Ph.D.

    2010-01-01

    Full Text Available The relationships between institutional communication and media communication influence the shaping of social representations of public issues. This research article analyses these relationships based on the case study of the external communication of a public institution, the press releases of Spain’s Youth Institute (Instituto de la Juventud, aka, Injuve, during three years and their repercussion in the press during the same period of time. The results obtained in this research allowed drawing conclusions on the types of communication production of the aforementioned institution and the news treatment of such pieces of information by the printed and digital media. The press releases and the news items were studied using quantitative media content analysis which focused, especially, in referential issues like the information treatment, the thematic analysis, youth representations in the case of the releases; and the visibility of the press releases in the making of news

  12. ACTIVATED HOT PRESSING BEHAVIOR OF WC NANOPOWDERS

    Directory of Open Access Journals (Sweden)

    Edwin GEVORKYAN

    2010-06-01

    Full Text Available The questions of consolidation of nanopowders concerning hot compaction by pressing activated by electric current action are considered. Mechanisms of grain boundary creep-sliding which are sequentially prevalent in a forming of compacted structures under influence of temperature factor and in the presence of a direct electric heating are discussed. Structural-transformational sources and conditions of forming of high physical-mechanical properties of nanopowder refractory solid-state products are described.

  13. The antimatter. Press breakfast 23 may 2000

    International Nuclear Information System (INIS)

    Spiro, M.; Dejardin, M.; Debu, P.; Aleksan, R.

    2000-05-01

    This document brings together the subjects discussed during the Press breakfast of 23 may 2000 on the antimatter, with scientists of the CEA and the CNRS. It presents the research programs and the experiments on the antimatter and the symmetry violation: the CP LEAR and the NA48 experiments at CERN, the BaBar detector at SLAC, the fundamental research at the CEA and the impacts on the energy policy. It provides also links for more detailed inquiries. (A.L.B.)

  14. Press conference of the 15 october 2002

    International Nuclear Information System (INIS)

    2002-10-01

    Facing the public hostile purposes of october 2002, concerning the renewable energies, Andre Antolini, President of the renewable energies syndicate, proposed a press conference to give information, data and realizations on the renewable energies. The text of the conference is presented, as data on employment, biofuels, the wind energy, the hydro-electricity the greenhouse effect fight, the public opinion, the solar heating, the photovoltaic and the future projects and electric power supply for 2010. (A.L.B.)

  15. Design of jigs, fixtures and press tools

    CERN Document Server

    Venkataraman, K

    2015-01-01

    Textbook presenting the fundamentals of tool design with special focus on jigs, fixtures and die design Covers sections on sheet metal forming processes; turning, grinding, broaching, welding and modular fixtures; principles of clamping; and an Introduction to Presses and Auxiliary Equipment Author has many years' experience in both academic and industrial environments, and presents this work in an easily-accessible style End of chapter questions and answers assist the learning process for both practicing tooling designers and engineers, and manufacturing en

  16. Validation of gait analysis with dynamic radiostereometric analysis (RSA) in patients operated with total hip arthroplasty.

    Science.gov (United States)

    Zügner, Roland; Tranberg, Roy; Lisovskaja, Vera; Shareghi, Bita; Kärrholm, Johan

    2017-07-01

    We simultaneously examined 14 patients with OTS and dynamic radiostereometric analysis (RSA) to evaluate the accuracy of both skin- and a cluster-marker models. The mean differences between the OTS and RSA system in hip flexion, abduction, and rotation varied up to 9.5° for the skin-marker and up to 11.3° for the cluster-marker models, respectively. Both models tended to underestimate the amount of flexion and abduction, but a significant systematic difference between the marker and RSA evaluations could only be established for recordings of hip abduction using cluster markers (p = 0.04). The intra-class correlation coefficient (ICC) was 0.7 or higher during flexion for both models and during abduction using skin markers, but decreased to 0.5-0.6 when abduction motion was studied with cluster markers. During active hip rotation, the two marker models tended to deviate from the RSA recordings in different ways with poor correlations at the end of the motion (ICC ≤0.4). During active hip motions soft tissue displacements occasionally induced considerable differences when compared to skeletal motions. The best correlation between RSA recordings and the skin- and cluster-marker model was found for studies of hip flexion and abduction with the skin-marker model. Studies of hip abduction with use of cluster markers were associated with a constant underestimation of the motion. Recordings of skeletal motions with use of skin or cluster markers during hip rotation were associated with high mean errors amounting up to about 10° at certain positions. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1515-1522, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. The effects of therapeutic hip exercise with abdominal core activation on recruitment of the hip muscles.

    Science.gov (United States)

    Chan, Mandy Ky; Chow, Ka Wai; Lai, Alfred Ys; Mak, Noble Kc; Sze, Jason Ch; Tsang, Sharon Mh

    2017-07-21

    Core stabilization has been utilized for rehabilitation and prevention of lower limb musculoskeletal injuries. Previous studies showed that activation of the abdominal core muscles enhanced the hip muscle activity in hip extension and abduction exercises. However, the lack of the direct measurement and quantification of the activation level of the abdominal core muscles during the execution of the hip exercises affect the level of evidence to substantiate the proposed application of core exercises to promote training and rehabilitation outcome of the hip region. The aim of the present study was to examine the effects of abdominal core activation, which is monitored directly by surface electromyography (EMG), on hip muscle activation while performing different hip exercises, and to explore whether participant characteristics such as gender, physical activity level and contractile properties of muscles, which is assessed by tensiomyography (TMG), have confounding effect to the activation of hip muscles in enhanced core condition. Surface EMG of bilateral internal obliques (IO), upper gluteus maximus (UGMax), lower gluteus maximus (LGMax), gluteus medius (GMed) and biceps femoris (BF) of dominant leg was recorded in 20 young healthy subjects while performing 3 hip exercises: Clam, side-lying hip abduction (HABD), and prone hip extension (PHE) in 2 conditions: natural core activation (NC) and enhanced core activation (CO). EMG signals normalized to percentage of maximal voluntary isometric contraction (%MVIC) were compared between two core conditions with the threshold of the enhanced abdominal core condition defined as >20%MVIC of IO. Enhanced abdominal core activation has significantly promoted the activation level of GMed in all phases of clam exercise (P recruitment in Clam, HABD and PHE exercises, and this enhancement is correlated with higher physical activity and stiffer hip muscle. Our results suggest the potential application of abdominal core activation for

  18. Effect of HIP temperatures on the microstructure and mechanical properties of carbide dispersed Ti-48Al-1Mn mechanically alloyed compacts

    International Nuclear Information System (INIS)

    Ameyama, Kei; Hashii, Mitsuya; Imai, Nobuyuki; Fujii, Toshinori; Sasaki, Nobuyuki.

    1996-01-01

    The effect of hot isostatic pressing (HIP) temperature on the microstructure and mechanical properties of Ti-48 mol%Al-1 mol%Mn compacts fabricated by mechanical alloying was investigated. N-heptane was used as a process control agent for the mechanical alloying. The compacts HIP treated at 1173, 1373 or 1573 K showed an ultra-fine equiaxed grain structure, i.e., a microduplex structure, consisting of TiAl (γ) and Ti 2 AlC phases, and their average grain sizes were 185 nm, 510 nm and 1.5 μm, respectively. The γ phase was considered to be formed by an α → γ massive transformation during heating. On the other hand, the compacts HIP treated at 1623 or 1673 K showed quite different microstructures from the above HIP compacts. The 1623 K-HIP compact was composed of equiaxed γ grains, whose size was approximately 11.5 μm, rectangular shaped Ti 2 AlC particles, and a small amount of the grain boundary nucleated α phase. Although the 1673 K-HIP compact showed a microstructure similar to the 1623 K-HIP compact, the γ grains were coarsened to be approximately 27.8 μm in diameter and the Ti 2 AlC particles were more elongated rectangles. Furthermore, the amount of the grain boundary nucleated α phase was increased and the lamella α phase nucleated at γ twin boundaries was observed in the 1673 K-HIP compact. Mechanical properties determined by compressive testing at various temperatures made clear that the compacts HIP treated at 1173, 1373 or 1573 K have good workability at elevated temperatures and those HIP treated at 1623 or 1673 K have good high temperature strength. These mechanical properties were influenced significantly by the microstructure, especially by the grain size and morphology of the Ti 2 AlC phase. (author)

  19. Antipsychotic treatment and the risk of hip fracture in subjects with schizophrenia: a 10-year population-based case-control study.

    Science.gov (United States)

    Wu, Chi-Shin; Chang, Chia-Ming; Tsai, Yu-Ting; Huang, Ya-Wen; Tsai, Hui-Ju

    2015-09-01

    To investigate the association between antipsychotic treatment and risk of hip fracture in subjects with schizophrenia. Among patients with schizophrenia (ICD-9-CM code 295), 605 cases with hip fracture and 2,828 matched controls were identified from 2002 to 2011 using the National Health Insurance Research Database in Taiwan. The authors conducted a nested case-control study to investigate the association between antipsychotic treatment and risk of hip fracture in subjects with schizophrenia. The modifiable effects of age and gender were evaluated by stratified analysis. In addition, the effects of antipsychotic use, antipsychotic classes, and receptor-binding profiles of antipsychotics, individually, on hip fracture were estimated, and potential confounding factors were adjusted in subsequent analysis. Conditional logistic regressions were applied to determine the effect of antipsychotic treatment on hip fracture. Current antipsychotic use was associated with an increased risk for hip fracture (adjusted odds ratio [AOR] = 1.61; 95% CI, 1.24-2.10). Among current users, new users had a higher risk of hip fracture (AOR = 4.28; 95% CI, 1.76-10.36) than past users (AOR = 1.11; 95% CI, 0.79-1.56). In addition, a significant increased risk of hip fracture was noted in schizophrenia subjects with first-generation antipsychotic use (AOR = 1.59; 95%CI, 1.15-2.20) but not in those with second-generation antipsychotic use (AOR = 1.16; 95% CI, 0.91-1.48). These results extend previous findings and demonstrate an increased risk of hip fracture associated with antipsychotic use in schizophrenia subjects. Further investigation is needed to dissect the underlying mechanisms related to the effect of antipsychotic use on hip fracture in subjects at risk. © Copyright 2015 Physicians Postgraduate Press, Inc.

  20. The risk of second hip fracture is decreased with compliant and persistent use of bisphosphonates

    DEFF Research Database (Denmark)

    Hansen, Louise; Vestergaard, Peter; Petersen, Karin Dam

    experience a 19% increased mortality within the first year following hip fractures. Furthermore, studies have shown that within 10 years after first hip fracture 40% will experience another hip fracture. The risk for second hip fracture is markedly increased, initiating at a relative risk of 11.8 within...... the first month after fracture and does not normalise until 15 years later. Fracture prevention programs have focused on identifying patients at risk of secondary low energy trauma fractures. The secondary prevention programs for fractures begin immediately after the first fracture, through identification...... of risk factors and initiate pharmaceutical treatment. The aim of this study was to estimate the potential benefits from alendronate treatment for secondary low energy trauma fracture patients in Denmark, compared to no pharmaceutical treatment for this group of patients. METHODS: A Markov model...