WorldWideScience

Sample records for preparing radiometal labeled

  1. Microfluidic Radiometal Labeling Systems for Biomolecules

    Energy Technology Data Exchange (ETDEWEB)

    Reichert, D E; Kenis, P J. A.

    2011-12-29

    In a typical labeling procedure with radiometals, such as Cu-64 and Ga-68; a very large (~ 100-fold) excess of the non-radioactive reactant (precursor) is used to promote rapid and efficient incorporation of the radioisotope into the PET imaging agent. In order to achieve high specific activities, careful control of reaction conditions and extensive chromatographic purifications are required in order to separate the labeled compounds from the cold precursors. Here we propose a microfluidic approach to overcome these problems, and achieve high specific activities in a more convenient, semi-automated fashion and faster time frame. Microfluidic reactors, consisting of a network of micron-sized channels (typical dimensions in the range 10 - 300¼m), filters, separation columns, electrodes and reaction loops/chambers etched onto a solid substrate, are now emerging as an extremely useful technology for the intensification and miniaturization of chemical processes. The ability to manipulate, process and analyze reagent concentrations and reaction interfaces in both space and time within the channel network of a microreactor provides the fine level of reaction control that is desirable in PET radiochemistry practice. These factors can bring radiometal labeling, specifically the preparation of radio-labeled biomolecules such as antibodies, much closer to their theoretical maximum specific activities.

  2. Effect of a spacer moiety on radiometal labelled Neurotensin derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Mascarin, A.; Valverde, I.E.; Mindt, T.L. [Univ. of Basel Hospital (Switzerland). Div. of Radiopharmaceutical Chemistry

    2013-07-01

    The binding sequence of the regulatory peptide Neurotensin, NT(8-13), represents a promising tumour-specific vector for the development of radiopeptides useful in nuclear oncology for the diagnosis (imaging) and therapy of cancer. A number of radiometal-labelled NT(8-13) derivatives have been reported, however, the effect of the spacer which connects the vector with the radiometal complex has yet not been investigated systematically. Because a spacer moiety can influence potentially important biological characteristics of radiopeptides, we synthesized three [DOTA({sup 177}Lu)]-X-NT(8-13) derivatives and evaluated the effect of a spacer (X) on the physico-chemical properties of the conjugate including lipophilicity, stability, and in vitro receptor affinity and cell internalization. (orig.)

  3. Radiochemical aspects of production and processing of radiometals for preparation of metalloradiopharmaceuticals

    OpenAIRE

    Zhernosekov, Konstantin P.

    2006-01-01

    Radiometals play an important role in nuclear medicine as involved in diagnostic or therapeutic agents. In the present work the radiochemical aspects of production and processing of very promising radiometals of the third group of the periodic table, namely radiogallium and radiolanthanides are investigated. The 68Ge/68Ga generator (68Ge, T½ = 270.8 d) provides a cyclotron-independent source of positron-emitting 68Ga (T½ = 68 min), which can be used for coordinative labelling. However, f...

  4. Preparation of Radiopharmaceuticals Labeled with Metal Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    2012-02-16

    The overall goal of this project was to develop methods for the production of metal-based radionuclides, to develop metal-based radiopharmaceuticals and in a limited number of cases, to translate these agents to the clinical situation. Initial work concentrated on the application of the radionuclides of Cu, Cu-60, Cu-61 and Cu-64, as well as application of Ga-68 radiopharmaceuticals. Initially Cu-64 was produced at the Missouri University Research Reactor and experiments carried out at Washington University. A limited number of studies were carried out utilizing Cu-62, a generator produced radionuclide produced by Mallinckrodt Inc. (now Covidien). In these studies, copper-62-labeled pyruvaldehyde Bis(N{sup 4}-methylthiosemicarbazonato)-copper(II) was studied as an agent for cerebral myocardial perfusion. A remote system for the production of this radiopharmaceutical was developed and a limited number of patient studies carried out with this agent. Various other copper radiopharmaceuticals were investigated, these included copper labeled blood imaging agents as well as Cu-64 labeled antibodies. Cu-64 labeled antibodies targeting colon cancer were translated to the human situation. Cu-64 was also used to label peptides (Cu-64 octriatide) and this is one of the first applications of a peptide radiolabeled with a positron emitting metal radionuclide. Investigations were then pursued on the preparation of the copper radionuclides on a small biomedical cyclotron. A system for the production of high specific activity Cu-64 was developed and initially the Cu-64 was utilized to study the hypoxic imaging agent Cu-64 ATSM. Utilizing the same target system, other positron emitting metal radionuclides were produced, these were Y-86 and Ga-66. Radiopharmaceuticals were labeled utilizing both of these radionuclides. Many studies were carried out in animal models on the uptake of Cu-ATSM in hypoxic tissue. The hypothesis is that Cu-ATSM retention in vivo is dependent upon the

  5. Extracorporeal adsorption therapy: A Method to improve targeted radiation delivered by radiometal-labeled monoclonal antibodies.

    Energy Technology Data Exchange (ETDEWEB)

    Nemecek, Eneida R.; Green, Damian J.; Fisher, Darrell R.; Pagal, John M.; Lin, Yukang; Gopal, A. K.; Durack, Lawrence D.; Rajendran, Joseph G.; Wilbur, D. S.; Nilsson, Rune; Sandberg, Bengt; Press, Oliver W.

    2008-04-01

    antibody labeled with indium-111 (111In), seven patients received RIT with anti-CD20 antibody labeled with indium-111 for biokinetics and dosimetry, and therapeutic doses of antibody labeled with yttrium-90 (90Y). Performing the ECAT procedure at a rate that such that one blood volume per hour were circulated for 3 hours, resulted in mean radioactivity depletion of 96% in whole blood, 49% in whole body 49%, 62% in the lungs and 40% in liver and kidneys. There was no sufficient data to determine whether there was an improvement in the relative delivery of radiation to the tumor compared to normal organs by performing ECAT, but pharmacokinetic modeling studies suggested a potential therapeutic advantage using this approach. [refs] To evaluate the potential therapeutic advantages of ECAT, we performed biodistribution studies in nonhuman primates comparing the therapeutic ratios of radiation delivered using this approach to those delivered by conventional RIT alone. In addition, we evaluated lutetium-177 (177Lu) as an alternative isotope to optimize the delivery of RIT by improving the therapeutic index (target to non-target ratio)

  6. Preparation of radiopharmaceuticals labeled with metal radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1992-06-01

    We recently developed a useful zinc-62/copper-62 generator and are presently evaluating copper-62 radiopharmaceuticals for clinical studies. While developing these copper-62 radiopharmaceuticals, in collaboration with the University of Missouri Research Reactor, Columbia we have also explored copper-64 radiopharmaceuticals. The PET images we obtained with copper-64 tracers were of such high quality that we have developed and evaluated copper-64 labeled antibodies for PET imaging. The major research activities described herein include: the development and assessment of gallium-68 radiopharmaceuticals; the development and evaluation of a new zinc-62/copper-62 generator and the assessment of copper-62 radiopharmaceuticals; mechanistic studies on proteins labeled with metal radionuclides.

  7. Preparation of radioiodine labelled thiouracil derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Visser, T.J.; Klootwijk, W. (Erasmus Univ., Rotterdam (Netherlands))

    1981-05-01

    2-Thiouracil and 6-propyl-2-thiouracil are radioiodinated with high yield using the chloramine-T method at low pH to prevent oxidation of the sulfur. The radioiodine-labelled derivatives are purified by adsorption chromatography on Sephadex G-10. The identity and purity of the products obtained are demonstrated by both normal- and reversed-phase high pressure liquid chromatography. The specific activity of the tracers amounts to approximately 1750 Ci mmol/sup -1/. Conditions for storage are described as well. These radioactive compounds may be used in the investigation of the mechanism of action of thyroid peroxidase as well as of iodothyronine deiodinases.

  8. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    Energy Technology Data Exchange (ETDEWEB)

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  9. Preparation and characterization of deuterium-labeled glycosaminoglycans.

    Science.gov (United States)

    Naggi, A; Casu, B; Crippa, B; Magnaghi, S; Silvestro, L; Torri, G

    1994-01-01

    Heparin, NAcHep, DS, and CS were labeled with deuterium by N-reacetylating, with the deuterated acetic anhydride (CD3CO)2O, GAGs previously N-deacetylated (by hydrazinolysis) to the desired extent. Degrees of deuteration of the present preparations, as determined by 2H- and 1H-NMR were 15%, 51%, 49%, and 79% for heparin, NAcHep, DS, and CS, respectively. The NMR analysis (including the 13C spectra) of the labeled products indicated that deuterium labeling did not involve any substantial modification of the GAG structures. Also NMR signals associated with specific sequences of heparin for antithrombin and of DS for heparin cofactor II were essentially the same in the unlabeled and in the deuterated GAGs. The substantial retention of the original structure was confirmed by data on the degree of sulfation (by conductimetry) and on the electrophoretic mobility in acid buffer. On the other hand, HPLC/SEC data indicated some depolymerization of heparin and DS in the N-deacetylation step of the labeling reactions. HPLC/MS spectrometry permitted a clear identification of disaccharide and tetrasaccharide fragments obtained from deuterated GAGs by enzymic (heparinase, chondroitinase ABC) or chemical depolymerization (deaminative cleavage, Smith degradation), opening new prospects for studies of human pharmacokinetics, with differentiation of exogenous from endogenous GAGs.

  10. PHOCUS radiometer

    Directory of Open Access Journals (Sweden)

    O. Nyström

    2012-01-01

    Full Text Available PHOCUS – Particles, Hydrogen and Oxygen Chemistry in the Upper Summer Mesosphere is a Swedish sounding rocket experiment, launched in July 2011, with the main goal of investigating the upper atmosphere in the altitude range 50–110 km. This paper describes the SondRad instrument in the PHOCUS payload, the radiometer comprising two frequency channels, 183 GHz and 557 GHz, aimed at exploring the water vapour concentration distribution in connection with the appearance of noctilucent (night shining clouds. The design of the radiometer system has been done in a collaboration between Omnisys Instruments AB and the Group for Advanced Receiver Development (GARD at Chalmers University of Technology where Omnisys was responsible for the overall design, implementation, and verification of the radiometers and backend whereas GARD was responsible for the radiometer optics and calibration systems.

    The SondRad instrument covers the water absorption lines at 183 GHz and 557 GHz. The 183 GHz channel is a side-looking radiometer while the 557 GHz radiometer is placed along the rocket axis looking in the forward direction. Both channels employ sub-harmonically pumped Schottky mixers and FFT spectrometer backends with 67 kHz resolution.

    The radiometers include novel calibration systems specifically adjusted for use with each frequency channel. The 183 GHz channel employs a CW-pilot signal calibrating the entire receiving chain while the IF-chain of the 557 GHz channel is calibrated by injecting a signal from a reference noise source through a directional coupler.

    The instrument collected complete spectra for both the 183 GHz and the 557 GHz with 300 Hz data rate for the 183 GHz channel and 10 Hz data rate for the 557 GHz channel for about 60 s reaching the apogee of the flight trajectory and 100 s after that. With lossless data compression using variable resolution over the spectrum, the data set was reduced to 2 × 12 MByte.

  11. PHOCUS radiometer

    Directory of Open Access Journals (Sweden)

    O. Nyström

    2012-06-01

    Full Text Available PHOCUS – Particles, Hydrogen and Oxygen Chemistry in the Upper Summer Mesosphere is a Swedish sounding rocket experiment, launched in July 2011, with the main goal of investigating the upper atmosphere in the altitude range 50–110 km. This paper describes the SondRad instrument in the PHOCUS payload, a radiometer comprising two frequency channels (183 GHz and 557 GHz aimed at exploring the water vapour concentration distribution in connection with the appearance of noctilucent (night shining clouds. The design of the radiometer system has been done in a collaboration between Omnisys Instruments AB and the Group for Advanced Receiver Development (GARD at Chalmers University of Technology where Omnisys was responsible for the overall design, implementation, and verification of the radiometers and backend, whereas GARD was responsible for the radiometer optics and calibration systems.

    The SondRad instrument covers the water absorption lines at 183 GHz and 557 GHz. The 183 GHz channel is a side-looking radiometer, while the 557 GHz radiometer is placed along the rocket axis looking in the forward direction. Both channels employ sub-harmonically pumped Schottky mixers and Fast Fourier Transform Spectrometers (FFTS backends with 67 kHz resolution.

    The radiometers include novel calibration systems specifically adjusted for use with each frequency channel. The 183 GHz channel employs a continuous wave CW pilot signal calibrating the entire receiving chain, while the intermediate frequency chain (the IF-chain of the 557 GHz channel is calibrated by injecting a signal from a reference noise source through a directional coupler.

    The instrument collected complete spectra for both the 183 GHz and the 557 GHz with 300 Hz data rate for the 183 GHz channel and 10 Hz data rate for the 557 GHz channel for about 60 s reaching the apogee of the flight trajectory and 100 s after that. With lossless data compression using variable

  12. Imaging radiometers employing linear thermoelectric arrays

    Science.gov (United States)

    McManus, Timothy J.; Mickelson, Steve

    1999-07-01

    Infrared Solutions, Inc. has developed a family of radiometers which employ silicon microstructure uncooled linear thermoelectric arrays, prepared by Honeywell Technology Center. Included in the family is a handheld imaging radiometer for predictive and preventive maintenance having a frame time of 1.4 sec, a linescanner radiometer for monitoring of industrial web process, an imaging radiometer for monitoring stationary industrial processes such as a die casting, and a linescanner radiometer for monitoring the temperature distribution of railcar wheels on trains moving at speeds up to 80 mph.

  13. 21 CFR 201.310 - Phenindione; labeling of drug preparations intended for use by man.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Phenindione; labeling of drug preparations intended for use by man. 201.310 Section 201.310 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS: GENERAL LABELING Specific Labeling Requirements for Specific Drug Products § 201.310...

  14. Radioiodinated Exendin-4 Is Superior to the Radiometal-Labelled Glucagon-Like Peptide-1 Receptor Probes Overcoming Their High Kidney Uptake

    Science.gov (United States)

    Läppchen, Tilman; Tönnesmann, Roswitha; Eersels, Jos; Meyer, Philipp T.; Maecke, Helmut R.; Rylova, Svetlana N.

    2017-01-01

    GLP-1 receptors are ideal targets for preoperative imaging of benign insulinoma and for quantifying the beta cell mass. The existing clinical tracers targeting GLP-1R are all agonists with low specific activity and very high kidney uptake. In order to solve those issues we evaluated GLP-1R agonist Ex-4 and antagonist Ex(9–39) radioiodinated at Tyr40 side by side with [Nle14,Lys40(Ahx-DOTA-68Ga)NH2]Ex-4 (68Ga-Ex-4) used in the clinic. The Kd, Bmax, internalization and binding kinetics of [Nle14,125I-Tyr40-NH2]Ex-4 and [Nle14,125I-Tyr40-NH2]Ex(9–39) were studied in vitro using Ins-1E cells. Biodistribution and imaging studies were performed in nude mice bearing Ins-1E xenografts. In vitro evaluation demonstrated high affinity binding of the [Nle14,125I-Tyr40-NH2]Ex-4 agonist to the Ins-1E cells with fast internalization kinetics reaching a plateau after 30 min. The antagonist [Nle14,125I-Tyr40-NH2]Ex(9–39) did not internalize and had a 4–fold higher Kd value compared to the agonist. In contrast to [Nle14,125I-Tyr40-NH2]Ex(9–39), which showed low and transient tumor uptake, [Nle14,125I-Tyr40-NH2]Ex-4 demonstrated excellent in vivo binding properties with tumor uptake identical to that of 68Ga-Ex-4, but substantially lower kidney uptake resulting in a tumor-to-kidney ratio of 9.7 at 1 h compared to 0.3 with 68Ga-Ex-4. Accumulation of activity in thyroid and stomach for both peptides, which was effectively blocked by irenat, confirms that in vivo deiodination is the mechanism behind the low kidney retention of iodinated peptides. The 124I congener of [Nle14,125I-Tyr40-NH2]Ex-4 demonstrated a similar favourable biodistribution profile in the PET imaging studies in contrast to the typical biodistribution pattern of [Nle14,Lys40(Ahx-DOTA-68Ga)NH2]Ex-4. Our results demonstrate that iodinated Ex-4 is a very promising tracer for imaging of benign insulinomas. It solves the problem of high kidney uptake of the radiometal-labelled tracers by improving the tumor

  15. DOTA-NOC, a high-affinity ligand of somatostatin receptor subtypes 2, 3 and 5 for labelling with various radiometals.

    Science.gov (United States)

    Wild, Damian; Schmitt, Jörg S; Ginj, Mihaela; Mäcke, Helmut R; Bernard, Bert F; Krenning, Eric; De Jong, Marion; Wenger, Sandra; Reubi, Jean-Claude

    2003-10-01

    Earlier studies have shown that modification of the octapeptide octreotide in positions 3 and 8 may result in compounds with increased somatostatin receptor affinity that, if radiolabelled, display improved uptake in somatostatin receptor-positive tumours. The aim of a recent research study in our laboratory was to employ the parallel peptide synthesis approach by further exchanging the amino acid in position 3 of octreotide and coupling the macrocyclic chelator DOTA(1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) to these peptides for labelling with radiometals like gallium-67 or -68, indium-111, yttrium-90 and lutetium-177. The purpose was to find radiopeptides with an improved somatostatin receptor binding profile in order to extend the spectrum of targeted tumours. A first peptide, [111In,90Y-DOTA]-1-Nal3-octreotide (111In,90Y-DOTA-NOC), was isolated which showed an improved profile. InIII-DOTA-NOC exhibited the following IC50 values (nM) when studied in competition with [125I][Leu8, d-Trp22, Tyr25]somatostatin-28 (values for YIII-DOTA-NOC are shown in parentheses): sstr2, 2.9 +/- 0.1 (3.3 +/- 0.2); sstr3, 8 +/- 2 (26 +/- 1.9); sstr5, 11.2 +/- 3.5 (10.4 +/- 1.6). Affinity towards sstr1 and 4 was very low or absent. InIII-DOTA-NOC is superior to all somatostatin-based radiopeptides having this particular type of binding profile, including DOTA-lanreotide, and has three to four times higher binding affinity to sstr2 than InIII,YIII-DOTA-Tyr3-octreotide (InIII,YIII-DOTA-TOC). In addition, [111In]DOTA-NOC showed a specific and high rate of internalization into AR4-2J rat pancreatic tumour cells which, after 4 h, was about two times higher than that of [111In]DOTA-TOC and three times higher than that of [111In]DOTA-octreotide ([111In]DOTA-OC). The internalized radiopeptides were externalized intact upon 2 h of internalization followed by an acid wash. After 2-3 h of externalization a plateau is reached, indicating a steady-state situation explained by

  16. Compact Radiometers Expand Climate Knowledge

    Science.gov (United States)

    2010-01-01

    To gain a better understanding of Earth's water, energy, and carbon cycles, NASA plans to embark on the Soil Moisture Active and Passive mission in 2015. To prepare, Goddard Space Flight Center provided Small Business Innovation Research (SBIR) funding to ProSensing Inc., of Amherst, Massachusetts, to develop a compact ultrastable radiometer for sea surface salinity and soil moisture mapping. ProSensing incorporated small, low-cost, high-performance elements into just a few circuit boards and now offers two lightweight radiometers commercially. Government research agencies, university research groups, and large corporations around the world are using the devices for mapping soil moisture, ocean salinity, and wind speed.

  17. Preparation and characterization of 125 I labeled bovine serum albumin

    Directory of Open Access Journals (Sweden)

    K S Ashwitha Rai

    2015-01-01

    Full Text Available Bovine serum albumin is a model protein, which has been conventionally used as protein standard and in many areas of biochemistry, pharmacology and medicine. Radioiodination procedure for bovine serum albumin employing chloramine-T as an oxidant with slight modification was evaluated critically to establish the optimal conditions for the preparation of radiolabeled tracer ( 125 I-BSA with required specific activity without impairing the immune reactivity and biological activity. Optimized radioiodination procedure involving 10 µg of chloramine-T along with 20 µg of sodium metabisulphite with 60 seconds incubation at 2° yielded 125 I-BSA with high integrity.

  18. Preparation of soluble isotopically labeled human growth hormone produced in Escherichia coli.

    Science.gov (United States)

    Lee, Jin-Hee; Jeong, Ji-Seon; Kim, Sook-Kyung; Song, Jimyeong; Lee, Ji Youn; Baek, Soyun; Choi, Jun-Hyuk

    2016-11-01

    Isotopically labeled proteins have been used as internal standards for mass spectrometry (MS)-based absolute protein quantification. Although this approach can provide highly accurate analyses of proteins of interest within a complex mixture, one of the major limitations of this method is the difficulty in preparing uniformly labeled standards. Human growth hormone (hGH) is one of the most important hormones that circulate throughout the body, and its measurement is primarily of interest in the diagnosis and treatment of growth disorders. In order to provide a useful internal standard for MS-based hGH measurement, we describe an efficient strategy to produce a potentially valuable, stable isotope-labeled hGH with high purity and yield. The strategy involves the following steps: solubilization of hGH under labeling conditions, detection of stable isotope incorporation, large-scale purification, analysis of the labeled protein, and assessment of the labeling efficiency. We show that the yield of soluble hGH under selective isotopic labeling conditions can be greatly increased by optimizing protein expression and extraction. Our efficient method for generating isotopically labeled hGH does not influence the structural integrity of hGH. Finally, we assessed the efficiency of stable isotope labeling at the intact protein level, and the result was further verified by amino acid analysis. These results clearly indicate that our labeling approach allows an almost complete incorporation of (13)C6(15)N4-arginine into the hGH expressed in E.coli without detectable isotope scrambling.

  19. Preparation of 1-Anthroyl Nitrile as a strong Fluorophore for pre-column labeling of Hydroxysteroids

    OpenAIRE

    Shamsa F; Amini H

    2000-01-01

    The preparation of 1-anthroyl nitrile as a useful labeling reagent for derivatization of hydroxysteroids is reported. This compound was prepared by some modifications in the literature procedure including the usage of copper cyanide instead of the expensive trimethylsilyl cyanide for conversion of 1-anthroyl chloride to 1-anthroyl nitrile and conducting the conversion of anthracene-1-carboxylic acid to 1-anthroyl chloride at 40°C instead of 110°C to avoid the formation of impurities. Derivati...

  20. Preparation of tritium labelled synthanecine A and its bis-N-ethylcarbamate

    Energy Technology Data Exchange (ETDEWEB)

    Mattocks, A.R. (Medical Research Council, Carshalton (UK))

    1982-04-01

    A procedure is described for incorporating tritium into the 3-CH/sub 2/ side chain of synthanecine A, and preparing the carbamate, 2,3-bis-N-ethylcarbamoyloxymethyl-1-methyl-3-pyrroline, a hepatotoxic pyrrolizidine alkaloid analogue. The pyrrolizidine amino alcohol, retronecine, can be tritium labelled in a similar way.

  1. Simple method for preparation of fluor/hapten-labeled dUTP.

    Science.gov (United States)

    Nimmakayalu, M; Henegariu, O; Ward, D C; Bray-Ward, P

    2000-03-01

    Many projects, such as multiplex-fluorescence in situ hybridization (M-FISH) karyotyping, require the use of relatively large amounts of multiple fluor- or hapten-labeled nucleotides for the preparation of DNA probes. Such a requirement makes these experimental approaches prohibitively expensive for many researchers. The cost of such nucleotides can be reduced approximately 99% by purchasing the chemical precursors, fluor or hapten succinimidyl esters and 5-(3-aminoallyl)-2'-deoxyuridine 5' triphosphate (AA-dUTP), and performing the simple coupling/purification described here. It is possible to finish four to ten different fluor/hapten dUTP preparations of 2.5 microM scale within a 24 h period. The reagent cost for each preparation ranges from $33-$237 per microM, depending on the fluor/hapten. This laboratory uses such nucleotide preparations to prepare FISH probes by nick translation or PCR amplification.

  2. Radiometer on a Chip

    Science.gov (United States)

    Chattopadhyay, Goutam; Gill, John J.; Mehdi, Imran; Lee, Choonsup; Schlecht, Erich T.; Skalare, Anders; Ward, John S.; Siegel, Peter H.; Thomas, Bertrand C.

    2009-01-01

    The radiometer on a chip (ROC) integrates whole wafers together to p rovide a robust, extremely powerful way of making submillimeter rece ivers that provide vertically integrated functionality. By integratin g at the wafer level, customizing the interconnects, and planarizing the transmission media, it is possible to create a lightweight asse mbly performing the function of several pieces in a more conventiona l radiometer.

  3. Subcellular SIMS imaging of isotopically labeled amino acids in cryogenically prepared cells

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, Subhash

    2004-06-15

    Ion microscopy is a potentially powerful technique for localization of isotopically labeled molecules. In this study, L-arginine and phenylalanine amino acids labeled with stable isotopes {sup 13}C and {sup 15}N were localized in cultured cells with the ion microscope at 500 nm spatial resolution. Cells were exposed to the labeled amino acids and cryogenically prepared. SIMS analyses were made in fractured freeze-dried cells. A dynamic distribution was observed from labeled arginine-treated LLC-PK{sub 1} kidney cells at mass 28 ({sup 13}C{sup 15}N) in negative secondaries, revealing cell-to-cell heterogeneity and preferential accumulation of the amino acid (or its metabolite) in the nucleus and nucleolus of some cells. The smaller nucleolus inside the nucleus was clearly resolved in SIMS images and confirmed by correlative light microscopy. The distribution of labeled phenylalanine contrasted with arginine as it was rather homogeneously distributed in T98G human glioblastoma cells. Images of {sup 39}K, {sup 23}Na and {sup 40}Ca were also recorded to confirm the reliability of sample preparation and authenticity of the observed amino acid distributions. These observations indicate that SIMS techniques can provide a valuable technology for subcellular localization of nitrogen-containing molecules in proteomics since nitrogen does not have a radionuclide tracer isotope. Amino acids labeled with stable isotopes can be used as tracers for studying their transport and metabolism in distinct subcellular compartments with SIMS. Further studies of phenylalanine uptake in human glioblastoma cells may have special significance in boron neutron capture therapy (BNCT) as a boron analogue of phenylalanine, boronophenylalanine is a clinically approved compound for the treatment of brain tumors.

  4. Subcellular SIMS imaging of isotopically labeled amino acids in cryogenically prepared cells

    Science.gov (United States)

    Chandra, Subhash

    2004-06-01

    Ion microscopy is a potentially powerful technique for localization of isotopically labeled molecules. In this study, L-arginine and phenylalanine amino acids labeled with stable isotopes 13C and 15N were localized in cultured cells with the ion microscope at 500 nm spatial resolution. Cells were exposed to the labeled amino acids and cryogenically prepared. SIMS analyses were made in fractured freeze-dried cells. A dynamic distribution was observed from labeled arginine-treated LLC-PK 1 kidney cells at mass 28 ( 13C15N) in negative secondaries, revealing cell-to-cell heterogeneity and preferential accumulation of the amino acid (or its metabolite) in the nucleus and nucleolus of some cells. The smaller nucleolus inside the nucleus was clearly resolved in SIMS images and confirmed by correlative light microscopy. The distribution of labeled phenylalanine contrasted with arginine as it was rather homogeneously distributed in T98G human glioblastoma cells. Images of 39K, 23Na and 40Ca were also recorded to confirm the reliability of sample preparation and authenticity of the observed amino acid distributions. These observations indicate that SIMS techniques can provide a valuable technology for subcellular localization of nitrogen-containing molecules in proteomics since nitrogen does not have a radionuclide tracer isotope. Amino acids labeled with stable isotopes can be used as tracers for studying their transport and metabolism in distinct subcellular compartments with SIMS. Further studies of phenylalanine uptake in human glioblastoma cells may have special significance in boron neutron capture therapy (BNCT) as a boron analogue of phenylalanine, boronophenylalanine is a clinically approved compound for the treatment of brain tumors.

  5. Simple, fast preparation of gallium-68-labelled human serum albumin microspheres.

    Science.gov (United States)

    Yvert, J P; Mazière, B; Verhas, M; Comar, D

    1979-04-01

    Following a study of the main factors involved in the 68-Ga labelling of human serum albumin microspheres (H.S.A.M.), especially methods of production and preparation of active solution and conditions of radioelement fixation on the protein support, the practical details of a fast technique (60 min) based on the process described by Hnatowich are presented. This method gives high labelling yields (93 +/- 3%), and after washing of the microspheres leads to a radiopharmaceutical product almost without free 68Ga (less than 2%). The spheres ready for use carry a total radioactivity corresponding to about 35%, including decay, of the activity originally recovered in the generator eluate and to more than 98% of that, found in the final suspension. The labelled product is sterile, non-pyrogenic and non-toxic. When it is injected in animals by left ventrical catheterization the uptake rates in the heart, lungs, spleen, left kidney and right kidney are similar to those observed with reference 85Sr-labelled carbonized microspheres. This radiopharmaceutical, easy to prepare and having excellent biological and nuclear properties, seems ideally suited for the scanning of organs by position emission tomoscintigraphy.

  6. Preparation, characterization and pharmacokinetics of fluorescence labeled propylene glycol alginate sodium sulfate

    Science.gov (United States)

    Li, Pengli; Li, Chunxia; Xue, Yiting; Zhang, Yang; Liu, Hongbing; Zhao, Xia; Yu, Guangli; Guan, Huashi

    2014-08-01

    A rapid and sensitive fluorescence labeling method was developed and validated for the microanalysis of a sulfated polysaccharide drug,namely propylene glycol alginate sodium sulfate (PSS), in rat plasma. Fluorescein isothiocyanate (FITC) was selected to label PSS, and 1, 6-diaminohexane was used to link PSS and FITC in order to prepare FITC-labeled PSS (F-PSS) through a reductive amination reaction. F-PSS was identified by UV-Vis, FT-IR and 1H-NMR spectrum. The cell stability and cytotoxicity of F-PSS were tested in Madin-Darby canine kidney (MDCK) cells. The results indicated that the labeling efficiency of F-PSS was 0.522% ± 0.0248% and the absolute bioavailability was 8.39%. F-PSS was stable in MDCK cells without obvious cytotoxicity. The method was sensitive and reliable; it showed a good linearity, precision, recovery and stability. The FITC labeling method can be applied to investigating the absorption and metabolism of PSS and other polysaccharides in biological samples.

  7. Preparation of 1-Anthroyl Nitrile as a strong Fluorophore for pre-column labeling of Hydroxysteroids

    Directory of Open Access Journals (Sweden)

    Shamsa F

    2000-08-01

    Full Text Available The preparation of 1-anthroyl nitrile as a useful labeling reagent for derivatization of hydroxysteroids is reported. This compound was prepared by some modifications in the literature procedure including the usage of copper cyanide instead of the expensive trimethylsilyl cyanide for conversion of 1-anthroyl chloride to 1-anthroyl nitrile and conducting the conversion of anthracene-1-carboxylic acid to 1-anthroyl chloride at 40°C instead of 110°C to avoid the formation of impurities. Derivatization of cortisol and prednisolone by 1-anthroyl nitrile resulted in effective separation of these compounds by HPLC with a detection limit of about 20 pg.

  8. Influence of biological assay conditions on stability assessment of radiometal-labelled peptides exemplified using a {sup 177}Lu-DOTA-minigastrin derivative

    Energy Technology Data Exchange (ETDEWEB)

    Ocak, Meltem [Clinical Department of Nuclear Medicine, Medical University Innsbruck, A-6020, Innsbruck (Austria); Department of Pharmaceutical Technology, Pharmacy Faculty, Istanbul University, 34116, Istanbul (Turkey); Helbok, Anna; Guggenberg, Elisabeth von [Clinical Department of Nuclear Medicine, Medical University Innsbruck, A-6020, Innsbruck (Austria); Ozsoy, Y. [Department of Pharmaceutical Technology, Pharmacy Faculty, Istanbul University, 34116, Istanbul (Turkey); Kabasakal, Levent [Department of Nuclear Medicine, Cerrahpasa Medical Faculty, 34098, Istanbul (Turkey); Kremser, Leopold [Division of Clinical Biochemistry, Protein Micro-Analysis Facility, Biocenter, Medical University Innsbruck, A-6020, Innsbruck (Austria); Decristoforo, Clemens, E-mail: clemens.decristoforo@uki.a [Clinical Department of Nuclear Medicine, Medical University Innsbruck, A-6020, Innsbruck (Austria)

    2011-02-15

    Introduction: Lack of correlation between in vitro and in vivo stability is a general problem for the development of radiopeptides especially in the case of minigastrin derivatives for therapeutic applications. In this study, we compared the influence of experimental conditions on radiopeptide stability results in vitro using a model Minigastrin (MG) analogue labelled with Lu-177. Additionally, we attempted to characterize the main serum enzymatic cleavage sites by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) analysis. Methods: In vitro stability of a DOTA-minigastrin derivative ({sup 177}Lu-DOTA-His-His-Glu-Ala-Tyr-Gly-Trp-NIe-Asp-Phe-NH{sub 2}) was tested in serum, rat tissue homogenates and two different standardised enzymatic mixtures. Quantification of the metabolised radiopeptides at different time intervals was performed using reversed-phase high-performance liquid chromatography (RP-HPLC). Metabolites were characterised by MALDI-TOF-MS. Urine was collected after 15 min p.i. into the mice and compared with in vitro metabolites by RP-HPLC. Results: Faster degradation of the radiopeptide was found in blood in comparison with plasma and serum incubation and in components from rats faster than from human origin. Fast degradation was observed in kidney and liver homogenates as well as in standardised enzymatic mixtures, also revealing variations in the metabolic profile. In urine, no intact peptide was detected already 5 min post injection. MALDI-TOF-MS revealed major cleavage sites at the carboxy terminus of the peptide. Conclusion: Very variable results may be found when different kind of incubation media for testing radiopeptide stabilities is used. Serum incubation studies may overestimate stability; therefore, results should be interpreted with care and combined with alternative in vitro and in vivo investigations.

  9. Microwave Radiometer Profiler

    Data.gov (United States)

    Oak Ridge National Laboratory — The microwave radiometer profiler (MWRP) provides vertical profiles of temperature, humidity, and cloud liquid water content as a function of height or pressure at...

  10. Solar-Collector Radiometer

    Science.gov (United States)

    Kendall, J. M., Jr

    1984-01-01

    Water-cooled Kendall radiometer measures output of solar energy concentrators. Unit measures irradiance up to 30,000 solar constants with 1 percent accuracy and responds to wavelengths from ultraviolet to far infrared.

  11. Microwave Radiometer - high frequency

    Data.gov (United States)

    Oak Ridge National Laboratory — The Microwave Radiometer-High Frequency (MWRHF) provides time-series measurements of brightness temperatures from two channels centered at 90 and 150 GHz. These two...

  12. Preparation and use of recombinant protein G-gold complexes as markers in double labelling immunocytochemistry

    DEFF Research Database (Denmark)

    Balslev, Y; Hansen, Gert Helge

    1989-01-01

    Recombinant protein G (RPG) was conjugated to colloidal gold particles and used for immunocytochemistry. In this report, the preparation of RPG-gold conjugates (RPGG) and the application of these conjugates in spot blot tests and in double immunolabelling are described. The immunolabelling...... was performed on ultracryosections of pig small intestine using antibodies directed against aminopeptidase N and sucrase-isomaltase. The labelling efficiency of RPGG was compared to that of protein A-gold conjugates (PAG) in different compartments of the enterocyte. Quantification showed that the labelling...... intensity was dependent on the size of the marker as well as on the kind of protein used for complex formation. The distributions for RPGG and PAG were respectively: for the 12 nm particles, 10.3 and 6.2 particles/micron of length of microvillar membrane, 3.5 and 1.0 particles/micron2 of Golgi profile and 5...

  13. Preparation of Fluorescent Microcystin Derivatives by Direct Arginine Labelling and Their Biological Evaluation.

    Science.gov (United States)

    Grundler, Verena; Faltermann, Susanne; Fent, Karl; Gademann, Karl

    2015-07-27

    Microcystin is the most prevalent toxin produced by cyanobacteria and poses a severe threat to livestock, humans and entire ecosystems. We report the preparation of a series of fluorescent microcystin derivatives by direct arginine labelling of the unprotected peptides at the guanidinium side chain. This new method allows a simple late-stage diversification strategy for native peptides devoid of protecting groups under mild conditions. A series of fluorophores were conjugated to microcystin-LR in good to very good yield. The fluorescent probes displayed biological activity comparable to that of unlabelled microcystin, in both phosphatase inhibition assays and toxicity tests on the crustacean Thamnocephalus platyurus. In addition, we demonstrate that the fluorescent probes penetrated Huh7 cells. Whole-animal imaging was performed on T. platyurus: labelled compound was mainly observed in the digestive tract.

  14. Preparation and bioevaluation of 166Ho labelled hydroxyapatite (HA) particles for radiosynovectomy.

    Science.gov (United States)

    Unni, P R; Chaudhari, P R; Venkatesh, Meera; Ramamoorthy, N; Pillai, M R A

    2002-02-01

    The preparation of 166Ho labeled hydroxy apatite (HA) particles for radiosynovectomy applications is described in this paper. 166Ho was prepared by the irradiation of Ho2O3 at a flux of 1.8 x 10(13) neutrons/cm2/s for about 7 days. The irradiation resulted in the production of approximately 17 GBq of 166Ho activity at the end of six hours post end of bombardment and the corresponding specific activity was approximately 3-4 GBq/mg of Ho. The irradiated target was dissolved in 0.1 N HCl solution. Radionuclidic purity was ascertained by high resolution gamma ray spectrometry. HA particles were synthesized and characterized by X-ray diffractometry. Labeling studies were carried out with and without citric acid as a transchelating agent. Radiochemical yield and purity of the 166Ho-HA particles were ascertained by paper chromatography and by paper electrophoresis techniques. Labeling yield of >98% could be achieved at pH 7, with 40 mg of HA particles and 8.6 microg of Ho. 166Ho-HA particles prepared were stable for 72 h. Bio-evaluation of the 166Ho -HA particles were carried out by injecting approximately 74 MBq dose in 200 microL (approximately 8 mg of 166Ho-HA particles) directly into the arthritis induced knee joints as well as into the healthy knee joints of white New Zealand rabbits. Images of the injected joints of the animals recorded using a gamma camera at regular intervals showed good retention. Blood samples were collected from the animals and activity assayed in a scintillation detector. Experiments were also carried out under identical conditions in normal rabbits. In both the cases, it was observed that there was no significant extra articular leakage of the injected activity over the study period of 96 h post injection.

  15. Preparation and preclinical evaluation of {sup 211}At-labelled compounds for {alpha}-particle radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.H.

    1994-12-31

    The interest for {alpha}-particle emitters in internal radiotherapy is increasing due to improved conjugation chemistry. Experimental work has concentrated on {sup 211}At and {sup 212}Bi since these to nuclides have radiochemical and physical properties suitable for medical application. In this report it is demonstrated that biologically active {sup 211}At-labelled compounds can be prepared within a relatively short time allowing utilization of this 7.2 h {alpha}-particle. It is further shown that {sup 211}At-TP-3 treatment of human osteosarcoma in vitro gives promising therapeutic ratios. 76 refs., 5 figs., 3 tabs.

  16. Efficient preparation and labeling of human induced pluripotent stem cells by nanotechnology

    Directory of Open Access Journals (Sweden)

    Jing Ruan

    2011-02-01

    Full Text Available Jing Ruan1,*, Jie Shen2,*, Zheng Wang2, Jiajia Ji1, Hua Song1, Kan Wang1, Bin Liu1, Jinhui Li2, Daxiang Cui11Department of Bio-Nano Science and Engineering, Key Laboratory for Thin Film and Microfabrication Technology of the Ministry of Education, National Key Laboratory of Micro/Nano Fabrication Technology, Research Institute of Micro/Nano Science and Technology, Shanghai Jiao Tong University, Shanghai, People’s Republic of China; 2Shanghai Institute of Digestive Diseases, Shanghai Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China. *These two authors contributed equally to this workAbstract: Efficient preparation and labeling of human induced pluripotent stem (iPS cells is a great challenge in stem cell research and development. With the aim of investigating the feasibility of using nanotechnology to enhance the preparation efficiency of iPS cells and to label iPS cells for long-term tracing and imaging, in this paper, four transcription factor genes, ie, Oct4, Sox2, LIN28, and Nanog, and packaging plasmids such as PSPAX2 and PMD2.G were cotransfected into 293T cells using Generation 5.0 polyamidoamine dendrimer-modified magnetic nanoparticles (dMNPs as a delivery system. The resultant supernatant liquids were incubated with human fibroblast cells at 37°C for 21 days, then the embryonic stem (ES cell-like clones were screened, cultured, and identified. Finally, the prepared iPS cells were labeled with fluorescent magnetic nanoparticles (FMNPs. The results showed that dMNPs can efficiently deliver all vectors into 293T cells. The resultant lentiviruses’ titers were 10-fold more than those based on Lipofectamine™ 2000. Reverse transcription polymerase chain reaction analysis showed that four genes (Oct4, Sox2, LIN28, and Nanog exhibited different expressions in iPS cells. Immunostaining analysis showed that specific surface markers of ES cells such as SSEA-3, SSEA-4, Tra-1-60, and Tra

  17. The Boundary Layer Radiometer

    Science.gov (United States)

    Irshad, Ranah; Bowles, N. E.; Calcutt, S. B.; Hurley, J.

    2010-10-01

    The Boundary Layer Radiometer is a small, low mass (<1kg) radiometer with only a single moving part - a scan/calibration mirror. The instrument consists of a three mirror telescope system incorporating an intermediate focus for use with miniature infrared and visible filters. It also has an integrated low power blackbody calibration target to provide long-term calibration stability The instrument may be used as an upward looking boundary layer radiometer for both the terrestrial and Martian atmospheres with appropriate filters for the mid-infrared carbon dioxide band, as well as a visible channel for the detection of aerosol components such as dust. The scan mirror may be used to step through different positions from the local horizon to the zenith, allowing the vertical temperature profile of the atmosphere to be retrieved. The radiometer uses miniature infrared filter assemblies developed for previous space-based instruments by Oxford, Cardiff and Reading Universities. The intermediate focus allows for the use of upstream blocking filters and baffles, which not only simplifies the design of the filters and focal plane assembly, but also reduces the risk of problems due to stray light. Combined with the calibration target this means it has significant advantages over previous generations of small radiometers.

  18. The conical scan radiometer

    Science.gov (United States)

    Prosch, T.; Hennings, D.

    1982-07-01

    A satellite-borne conical scan radiometer (CSR) is proposed, offering multiangular and multispectral measurements of Earth radiation fields, including the total radiances, which are not available from conventional radiometers. Advantages of the CSR for meteorological studies are discussed. In comparison to conventional cross track scanning instruments, the CSR is unique with respect to the selected picture element size which is kept constant by means of a specially shaped detector matrix at all scan angles. The conical scan mode offers the chance to improve angular sampling. Angular sampling gaps of previous satellite-borne radiometers can be interpolated and complemented by CSR data. Radiances are measured through 10 radiometric channels which are selected to study cloudiness, water vapor, ozone, surface albedo, ground and mean stratospheric temperature, and aerosols.

  19. Electron Cyclotron Emission Radiometer

    Science.gov (United States)

    Morales, Cristina

    2009-11-01

    There is much interest in studying plasmas that generate hot electrons. The goal of this project is to develop a wide band electron cyclotron radiometer to measure the non-Maxwellian rapid rises in electron temperature. These rapid increases in temperature will then be correlated to instabilities in the plasma. This project explores a type of noncontact temperature measurement. We will attempt to show the feasibility of electron cyclotron emissions to measure the Maryland Centrifugal Experiment's electron plasma temperature. The radiometer has been designed to have 100dB of gain and a sensitivity of 24mV/dB given by its logarithmic amplifier. If successful, this radiometer will be used as a diagnostic tool in later projects such as the proposed experiment studying magnetic reconnection using solar flux loops.

  20. A Multifrequency Radiometer System

    DEFF Research Database (Denmark)

    Skou, Niels

    1977-01-01

    A radiometer system having four channels: 5 GHz, l7 GHz, 34 GHz, all vertical polarization, and a 34 GHz sky horn, will be described. The system which is designed for collecting glaciological and oceanographic data is intended for airborne use and imaging is achieved by means of a multifrequency ...... elaborate processing later, using ground facilities. In conjunction with a side looking radar which is under development at present, the radiometers are intended as the remote sensing basis for an all-weather ice reconnaissance service in the Greenland seas....

  1. Microwave Radiometer (MWR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Morris, VR

    2006-08-01

    The Microwave Radiometer (MWR) provides time-series measurements of column-integrated amounts of water vapor and liquid water. The instrument itself is essentially a sensitive microwave receiver. That is, it is tuned to measure the microwave emissions of the vapor and liquid water molecules in the atmosphere at specific frequencies.

  2. Statistical Topics Concerning Radiometer Theory

    CERN Document Server

    Hunter, Todd R

    2015-01-01

    We present a derivation of the radiometer equation based on the original references and fundamental statistical concepts. We then perform numerical simulations of white noise to illustrate the radiometer equation in action. Finally, we generate 1/f and 1/f^2 noise, demonstrate that it is non-stationary, and use it to simulate the effect of gain fluctuations on radiometer performance.

  3. Preparation of goat and rabbit anti-camel immunoglobulin G whole molecule labeled with horseradish peroxidase

    Directory of Open Access Journals (Sweden)

    Eman Hussein Abdel-Rahman

    2017-01-01

    Full Text Available Aim: As the labeled anti-camel immunoglobulins (Igs with enzymes for enzyme-linked immunosorbent assay (ELISA are unavailable in the Egyptian market, the present investigation was directed for developing local labeled anti-camel IgG with horseradish peroxidase (HRP to save hard curacy. Materials and Methods: For purification of camel IgG whole molecule, camel sera was preliminary precipitated with 50% saturated ammonium sulfate and dialyzed against 15 mM phosphate-buffered saline pH 7.2 then concentrated. This preparation was further purified by protein A sepharose affinity column chromatography. The purity of the eluted camel IgG was tested by sodium dodecyl sulfate polyacrylamide gel electrophoresi. Anti-camel IgG was prepared by immunization of goats and rabbits separately, with purified camel IgG. The anti-camel IgG was purified by protein A sepharose affinity column chromatography. Whole molecule anti-camel IgG was conjugated with HRP using glutraldehyde based assay. Sensitivity and specificity of prepared conjugated secondary antibodies were detected using positive and negative camel serum samples reacted with different antigens in ELISA, respectively. The potency of prepared conjugated antibodies was evaluated compared with protein A HRP. The stability of the conjugate at −20°C during 1 year was assessed by ELISA. Results: The electrophoretic profile of camel IgG showed four bands of molecular weight 63, 52, 40 and 33 kDa. The recorded sensitivity and specificity of the product are 100%. Its potency is also 100% compared to 58-75% of commercial protein A HRP. The conjugates are stable for 1 year at −20°C as proved by ELISA. Conclusion: Collectively, this study introduces goat and rabbit anti-camel IgG whole molecules with simple, inexpensive method, with 100% sensitivity, 100% specificity and stability up to 1 year at −20°C. The important facet of the current study is saving hard curacy. Future investigations are necessary for

  4. Preparation of goat and rabbit anti-camel immunoglobulin G whole molecule labeled with horseradish peroxidase

    Science.gov (United States)

    Abdel-Rahman, Eman Hussein; El-Jakee, Jakeen Kamal; Hatem, Mahmoud Essam; Ata, Nagwa Sayed; Fouad, Ehab Ali

    2017-01-01

    Aim: As the labeled anti-camel immunoglobulins (Igs) with enzymes for enzyme-linked immunosorbent assay (ELISA) are unavailable in the Egyptian market, the present investigation was directed for developing local labeled anti-camel IgG with horseradish peroxidase (HRP) to save hard curacy. Materials and Methods: For purification of camel IgG whole molecule, camel sera was preliminary precipitated with 50% saturated ammonium sulfate and dialyzed against 15 mM phosphate-buffered saline pH 7.2 then concentrated. This preparation was further purified by protein A sepharose affinity column chromatography. The purity of the eluted camel IgG was tested by sodium dodecyl sulfate polyacrylamide gel electrophoresi. Anti-camel IgG was prepared by immunization of goats and rabbits separately, with purified camel IgG. The anti-camel IgG was purified by protein A sepharose affinity column chromatography. Whole molecule anti-camel IgG was conjugated with HRP using glutraldehyde based assay. Sensitivity and specificity of prepared conjugated secondary antibodies were detected using positive and negative camel serum samples reacted with different antigens in ELISA, respectively. The potency of prepared conjugated antibodies was evaluated compared with protein A HRP. The stability of the conjugate at −20°C during 1 year was assessed by ELISA. Results: The electrophoretic profile of camel IgG showed four bands of molecular weight 63, 52, 40 and 33 kDa. The recorded sensitivity and specificity of the product are 100%. Its potency is also 100% compared to 58-75% of commercial protein A HRP. The conjugates are stable for 1 year at −20°C as proved by ELISA. Conclusion: Collectively, this study introduces goat and rabbit anti-camel IgG whole molecules with simple, inexpensive method, with 100% sensitivity, 100% specificity and stability up to 1 year at −20°C. The important facet of the current study is saving hard curacy. Future investigations are necessary for preparation of Ig

  5. Zinc phthalocyanine labelled polyethylene glycol: preparation, characterization, interaction with bovine serum albumin and near infrared fluorescence imaging in vivo.

    Science.gov (United States)

    Lv, Feng; Cao, Bo; Cui, Yanli; Liu, Tianjun

    2012-05-25

    Zinc phthalocyanine labelled polyethylene glycol was prepared to track and monitor the in vivo fate of polyethylene glycol. The chemical structures were characterized by nuclear magnetic resonance and infrared spectroscopy. Their light stability and fluorescence quantum yield were evaluated by UV-Visible and fluorescence spectroscopy methods. The interaction of zinc phthalocyanine labelled polyethylene glycol with bovine serum albumin was evaluated by fluorescence titration and isothermal titration calorimetry methods. Optical imaging in vivo, organ aggregation as well as distribution of fluorescence experiments for tracking polyethylene glycol were performed with zinc phthalocyanine labelled polyethylene glycol as fluorescent agent. Results show that zinc phthalocyanine labelled polyethylene glycol has good optical stability and high emission ability in the near infrared region. Imaging results demonstrate that zinc phthalocyanine labelled polyethylene glycol can track and monitor the in vivo process by near infrared fluorescence imaging, which implies its potential in biomaterials evaluation in vivo by a real-time noninvasive method.

  6. Preparation of 19-iodo cholesterol labelled with 125 I; Preparacion del 19-yodocolesterol marcado con 125 I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Rebollo, D. V.; Ruiz, J. M.

    1986-07-01

    In this paper a new method of synthesis of 19-iodo cholesterol labelled with ''125 I, from commercial cholesterol, is described. Its high chemical (96%) and radiochemical (99.9%) purities high yield and short time of preparation permit us to dispose or a more accessible labelled compound, which results appropriates for clinical investigations and in the diagnosis of disturbances of the suprarenal glands. (Author) 9 refs.

  7. Preparation and Characterization of {sup 177}Lu Labeled Antibody against Tyrosine Kinase Receptor Her2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So-Young; Hong, Young-Don; Choi, Sun-Ju [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-05-15

    The tyrosine kinase receptor Her2, also known in humans as erbB2, is a member of the epidermal growth factor receptor (EGFR or erbB1) family. The Her2 is highly expressed in many cancer types and over expressed in approximately 30% of all primary breast cancer. Overexpression of Her2 is associated with a poor prognosis. Her2 is a suitable target because it involves an extracellular domain that can be targeted by antibodies produced by B cells. Based on these advantages, we tried to prepare the {sup 177}Lu labeled Her2 antibody. This radioimmunoconjugate could act by not only blocking the Her2 signalling pathway using antibody but also killing the tumour cell using {beta} energy of {sup 177}Lu.

  8. Preparation of fluorescent-dye-labeled cDNA from RNA for microarray hybridization.

    Science.gov (United States)

    Ares, Manuel

    2014-01-01

    This protocol describes how to prepare fluorescently labeled cDNA for hybridization to microarrays. It consists of two steps: first, a mixture of anchored oligo(dT) and random hexamers is used to prime amine-modified cDNA synthesis by reverse transcriptase using a modified deoxynucleotide with a reactive amine group (aminoallyl-dUTP) and an RNA sample as a template. Second, the cDNA is purified and exchanged into bicarbonate buffer so that the amine groups in the cDNA react with the dye N-hydroxysuccinimide (NHS) esters, covalently joining the dye to the cDNA. The dye-coupled cDNA is purified again, and the amount of dye incorporated per microgram of cDNA is determined.

  9. Hurricane Imaging Radiometer

    Science.gov (United States)

    Cecil, Daniel J.; Biswas, Sayak K.; James, Mark W.; Roberts, J. Brent; Jones, W. Linwood; Johnson, James; Farrar, Spencer; Sahawneh, Saleem; Ruf, Christopher S.; Morris, Mary; hide

    2014-01-01

    The Hurricane Imaging Radiometer (HIRAD) is a synthetic thinned array passive microwave radiometer designed to allow retrieval of surface wind speed in hurricanes, up through category five intensity. The retrieval technology follows the Stepped Frequency Microwave Radiometer (SFMR), which measures surface wind speed in hurricanes along a narrow strip beneath the aircraft. HIRAD maps wind speeds in a swath below the aircraft, about 50-60 km wide when flown in the lower stratosphere. HIRAD has flown in the NASA Genesis and Rapid Intensification Processes (GRIP) experiment in 2010 on a WB-57 aircraft, and on a Global Hawk unmanned aircraft system (UAS) in 2012 and 2013 as part of NASA's Hurricane and Severe Storms Sentinel (HS3) program. The GRIP program included flights over Hurricanes Earl and Karl (2010). The 2012 HS3 deployment did not include any hurricane flights for the UAS carrying HIRAD. The 2013 HS3 flights included one flight over the predecessor to TS Gabrielle, and one flight over Hurricane Ingrid. This presentation will describe the HIRAD instrument, its results from the 2010 and 2013 flights, and potential future developments.

  10. Radiant Temperature Nulling Radiometer

    Science.gov (United States)

    2002-01-01

    A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied. The underlying principle of nulling and self-calibration is the same as that of a typical microwave radiometer, but because of differences between the characteristics of signals in the infrared and microwave spectral regions, the principle must be implemented in a different way. A detailed description of the instrument including an infrared photodetector equipped with focusing input optics [e.g., lens(es) and/or mirrors] and an input LWIR band-pass filter is presented.

  11. PET imaging of liposomes labeled with an [18F]-fluorocholesteryl ether probe prepared by automated radiosynthesis

    DEFF Research Database (Denmark)

    Jensen, Andreas Tue Ingemann; Binderup, Tina; Andresen, Thomas Lars;

    2012-01-01

    A novel [F-18]-labeled cholesteryl ether lipid probe was prepared by synthesis of the corresponding mesylate, which was [F-18]-fluorinated by a [F-18]KF, Kryptofix-222, K2CO3 procedure. Fluorination was done for 10 minutes at 165 degrees C and took place with conversion between 3 and 17%, dependi...

  12. Preparation and 177Lu Labeling of p-SCN-Bn-DOTA-h-R3

    Institute of Scientific and Technical Information of China (English)

    DENG; Xin-rong; FAN; Cai-yun; LUO; Zhi-fu

    2013-01-01

    The humanized monoclonal antibodies(mAbs)h-R3 has been used as a targeting biomolecule better than other anti-EGFR(epidermal growth factor receptor)for the delivery of radionuclide onto tumor cells in radio immunotherapy(RIT).Several bifunctional chelating agents(BCAs)could be used as a bridge coupling h-R3 and radiometals.In this study,h-R3 was conjugated with S-2-(4-isothiocyanatobenzyl)-1,4,

  13. Portable Diagnostic Radiometer.

    Science.gov (United States)

    1985-07-01

    noise. The single-throw-double-pole switch is usually realized with an electronically- switched , latching ferrite circulator; however, at these...R2. Dl, D2 and R2 are then displayed on the liquid crystal display. The Q lines are next set to switch the latching switches into the 800 MHz...operation is basically as follows: On start- up, the CPU resets the Q line (P1-6) which sets the latching switches (see Fig. 18) to the 4 GHz radiometer

  14. Preparation of a carbon-11 labelled analgesic -(N-methyl-/sup 11/C)meptazinol

    Energy Technology Data Exchange (ETDEWEB)

    Turton, D.R.; Luthra, S.K.; Pike, V.W.; Kensett, M.J.

    1987-09-01

    A procedure for labelling the novel analgesic, meptazinol ((+)1-methyl-3-ethyl-3-(m-hydroxyphenyl)tetrahydroazepine), with the positron-emitting radionuclide, carbon-11 has been developed in order to permit the pharmacokinetics of this analgesic to be studied in man. The procedure involves the reaction of (/sup 11/C)iodomethane with normeptazinol in ethanol, evaporation of any unreacted (/sup 11/C)iodomethane, purification by HPLC and removal of solvent. Subsequent solubilisation of the radioactive product in ethanol plus isotonic saline and sterilisation by filtration produces a safely-injectable solution of (N-methyl- /sup 11/C)meptazinol in 14% radiochemical yield. The specific activity of the product is up to 7.4 GBq/..mu..mol at the end of radiosynthesis. Preparations have been shown to be radiochemically pure and to be free of normeptazinol by analytical HPLC and TLC. That the radioactive product is (N-methyl- /sup 11/C)meptazinol has been unequivocally demonstrated by co-inclusion of /sup 13/C-enriched iodomethane in the radiosynthesis and examination of the product by broad-band proton-decoupled Fourier transform /sup 13/C-NMR spectroscopy.

  15. Preparation of carbon quantum dots with a high quantum yield and the application in labeling bovine serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Pengpeng; Zhang, Changchang; Liu, Xiang, E-mail: liuxiang@ahut.edu.cn; Cui, Ping, E-mail: cokecp@sohu.com

    2016-04-15

    Graphical abstract: - Highlights: • Cheap carbon quantum dots (CQDs) with a high quantum yield were prepared. • The preparation process and surface functionalization on CQDs are rather facile. • Such functionalized CQDs can be attached to BSA covalently. • This predicts that some biomolecules can be labeled by the fluorescent CQDs. - Abstract: An economic and green approach of manufacturing carbon quantum dots (CQDs) with a high quantum yield (denoted with HQY-CQDs) and the application in labeling bovine serum albumin (BSA) were described in detail in this work. Firstly, the cheap resources of citric acid and glycine were pyrolysed in drying oven for preparing the CQDs. Then the product was immersed in tetrahydrofuran for 8 h. HQY-CQDs were obtained by removing tetrahydrofuran from the supernate and were evaluated that they possessed a much higher quantum yield compared with that without dealing with tetrahydrofuran and a wonderful photo-bleaching resistance. Such HQY-CQDs could be functionalized by N-hydroxysuccinimide and successively combined with BSA covalently. Thus fluorescent labeling on BSA was realized. The HQY-CQDs were demonstrated with transmission electron microscopy and the chemical modification with N-hydroxysuccinimide was proved by infrared and X-ray photoelectron spectra. Labeling BSA with the HQY-CQDs was confirmed by gel electrophoresis and fluorescence imaging.

  16. In vitro preparation of radionuclides labeled blood cells: Status and requirements; Preparation in vitro des cellules du sang marquees par des radionucleides: statut et recommandations

    Energy Technology Data Exchange (ETDEWEB)

    Couret, I. [Service de medecine nucleaire et radiopharmacie, hopital Lapeyronie, CHU de Montpellier, 34 - Montpellier (France); Desruet, M.D. [Service de medecine nucleaire et radiopharmacie, CHU de Grenoble, 38 - Grenoble (France); Bolot, C. [Service de pharmacie, hospices civils de Lyon, groupement hospitalier Est, 69 - Bron (France); Chassel, M.L. [Service de pharmacie et radiopharmacie, centre hospitalier de Chambery, 73 - Chambery (France); Pellegrin, M. [Inserm U896, CRLC Val-d' Aurelle-Paul-Lamarque, IRCM, universite Montpellier 1, 34 - Montpellier (France)

    2010-11-15

    Labelled blood cells permit nuclear medicine imaging using their physiological behaviours. The radiolabeling must be performed in vitro because of the lack of specific markers and requires several highly technical stages of preparation. Labelled blood cells have not the medication drug status, so that the nuclear physician conducting the nuclear test is fully liable. In most cases, the physician delegates the technical responsibility to radio-pharmacists. Although the status of radiolabelled autologous cells is not legally defined and in the absence of a specific repository, it is essential that their preparation is subject to the requirements of the rules of French Good Manufacturing Practice published by Agence francaise de securite sanitaire des produits de sante (Afssaps). It would be desirable to harmonize the practices of radiolabeling cellular blood components by editing a repository. (authors)

  17. The beauty of being (label)-free: sample preparation methods for SWATH-MS and next-generation targeted proteomics

    Science.gov (United States)

    Campbell, Kate; Deery, Michael J.; Lilley, Kathryn S.; Ralser, Markus

    2014-01-01

    The combination of qualitative analysis with label-free quantification has greatly facilitated the throughput and flexibility of novel proteomic techniques. However, such methods rely heavily on robust and reproducible sample preparation procedures. Here, we benchmark a selection of in gel, on filter, and in solution digestion workflows for their application in label-free proteomics. Each procedure was associated with differing advantages and disadvantages. The in gel methods interrogated were cost effective, but were limited in throughput and digest efficiency. Filter-aided sample preparations facilitated reasonable processing times and yielded a balanced representation of membrane proteins, but led to a high signal variation in quantification experiments. Two in solution digest protocols, however, gave optimal performance for label-free proteomics. A protocol based on the detergent RapiGest led to the highest number of detected proteins at second-best signal stability, while a protocol based on acetonitrile-digestion, RapidACN, scored best in throughput and signal stability but came second in protein identification. In addition, we compared label-free data dependent (DDA) and data independent (SWATH) acquisition on a TripleTOF 5600 instrument. While largely similar in protein detection, SWATH outperformed DDA in quantification, reducing signal variation and markedly increasing the number of precisely quantified peptides. PMID:24741437

  18. Preparation and Biological Evaluation of 188Re Labeled Monoclonal Antibody TGLA

    Institute of Scientific and Technical Information of China (English)

    WEN; Kai; ZHANG; Jun-li; CHEN; Bao-jun; CUI; Hai-ping

    2012-01-01

    <正>Monoclonal antibody TGLA is a specific targeting CD20 chimeric antibody. It can kill tumor cells and inhibit tumor cells’ growth effectively, which has been applied to clinical therapy of lymphoma cell B. 188 Re is easy to get, and emits both β and γ rays. 188Re labeled monoclonal antibody TGLA can be used for the study of lymphoma therapy and imaging. This work got the product 188Re-TGLA by direct labeling

  19. Preparation of radiopharmaceuticals labeled with metal radionuclides. Progress report, July 1, 1988--June 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1992-06-01

    We recently developed a useful zinc-62/copper-62 generator and are presently evaluating copper-62 radiopharmaceuticals for clinical studies. While developing these copper-62 radiopharmaceuticals, in collaboration with the University of Missouri Research Reactor, Columbia we have also explored copper-64 radiopharmaceuticals. The PET images we obtained with copper-64 tracers were of such high quality that we have developed and evaluated copper-64 labeled antibodies for PET imaging. The major research activities described herein include: the development and assessment of gallium-68 radiopharmaceuticals; the development and evaluation of a new zinc-62/copper-62 generator and the assessment of copper-62 radiopharmaceuticals; mechanistic studies on proteins labeled with metal radionuclides.

  20. Pharmaceutical preparation of oxygen-15 labelled molecular oxygen and carbon monoxide gasses in a hospital setting.

    NARCIS (Netherlands)

    Luurtsema, Geert; Boellaard, Ronald; Greuter, Henri; Rijbroek, Abraham; Takkenkamp, Kevin; de Geest, Frank; Buijs, Fred; Hendrikse, NH; Franssen, Eric; van Lingen, Arthur; Lammertsma, Adriaan A.

    2010-01-01

    BACKGROUND: Clinical positron emission tomography (PET) requires safe and effective PET radiopharmaceuticals. Tracers used for measuring oxygen consumption and blood volume are [(15)O]O(2) and [(15)O]CO, respectively. In general, these oxygen-15 labelled tracers are produced using a cyclotron that a

  1. Straightforward preparation of labeled potassium cyanate by ozonation and application to the synthesis of [13C] or [14C]ureidocarboxylic acids.

    Science.gov (United States)

    Loreau, Olivier; Marlière, Philippe

    2013-06-15

    The development of new efficient syntheses of labeled reagents is a great challenge. Avoidance of overcomplicated procedures, availability and cost of starting materials are important considerations in choosing the synthetic route. In this report, we describe a facile and rapid preparation of labeled cyanate by ozonation of cyanide, a basic precursor. The crude cyanate was used without purification for the synthesis of various [(13)C] or [(14)C]ureidocarboxylic acids (20-68% yield from potassium cyanide). According to these results, cyanide ozonation may prove to be a promising alternative to traditional preparations of labeled cyanate.

  2. Preparation of carbon quantum dots with a high quantum yield and the application in labeling bovine serum albumin

    Science.gov (United States)

    Liu, Pengpeng; Zhang, Changchang; Liu, Xiang; Cui, Ping

    2016-04-01

    An economic and green approach of manufacturing carbon quantum dots (CQDs) with a high quantum yield (denoted with HQY-CQDs) and the application in labeling bovine serum albumin (BSA) were described in detail in this work. Firstly, the cheap resources of citric acid and glycine were pyrolysed in drying oven for preparing the CQDs. Then the product was immersed in tetrahydrofuran for 8 h. HQY-CQDs were obtained by removing tetrahydrofuran from the supernate and were evaluated that they possessed a much higher quantum yield compared with that without dealing with tetrahydrofuran and a wonderful photo-bleaching resistance. Such HQY-CQDs could be functionalized by N-hydroxysuccinimide and successively combined with BSA covalently. Thus fluorescent labeling on BSA was realized. The HQY-CQDs were demonstrated with transmission electron microscopy and the chemical modification with N-hydroxysuccinimide was proved by infrared and X-ray photoelectron spectra. Labeling BSA with the HQY-CQDs was confirmed by gel electrophoresis and fluorescence imaging.

  3. Potential therapeutic radiotracers: preparation, biodistribution and metabolic characteristics of 177Lu-labeled cyclic RGDfK dimer.

    Science.gov (United States)

    Shi, Jiyun; Liu, Zhaofei; Jia, Bing; Yu, Zilin; Zhao, Huiyun; Wang, Fan

    2010-06-01

    In this study, we reported the preparation and evaluation of (177)Lu-DOTA-RGD2, (177)Lu-DOTA-Bz-RGD2 and (177)Lu-DTPA-Bz-RGD2 (RGD2 = E[c(RGDfK)](2)) as a potential therapeutic radiotracers for the treatment of integrin alpha(v)beta(3)-positive tumors. The BALB/c nude mice bearing the U87MG human glioma xenografts were used to evaluate the biodistribution characteristics and excretion kinetics of (177)Lu-DOTA-RGD2, (177)Lu-DOTA-Bz-RGD2 and (177)Lu-DTPA-Bz-RGD2. It was found that there were no major differences in their lipophilicity and biodistribution characteristics, particularly at latter time points. A major advantage of using DTPA-Bz as the bifunctional chelator (BFC) was its high radiolabeling efficiency (fast and high yield radiolabeling) at room temperature. Using DOTA and DOTA-Bz as BFCs, the radiolabeling kinetics was slow, and heating at 100 degrees C and higher DOTA-conjugate concentration were needed for successful (177)Lu-labeling. Therefore, DTPA-Bz is an optimal BFC for routine preparation of (177)Lu-labeled cyclic RGDfK peptides, and (177)Lu-DTPA-Bz-RGD2 is worthy of further investigation for targeted radiotherapy of integrin alpha(v)beta(3)-positive tumors.

  4. Radiometer Testbed Development for SWOT

    Science.gov (United States)

    Kangaslahti, Pekka; Brown, Shannon; Gaier, Todd; Dawson, Douglas; Harding, Dennis; Fu, Lee-Lueng; Esteban-Fernandez, Daniel

    2010-01-01

    Conventional altimeters include nadir looking colocated 18-37 GHz microwave radiometer to measure wet tropospheric path delay. These have reduced accuracy in coastal zone (within 50 km from land) and do not provide wet path delay over land. The addition of high frequency channels to Jason-class radiometer will improve retrievals in coastal regions and enable retrievals over land. High-frequency window channels, 90, 130 and 166 GHz are optimum for improving performance in coastal region and channels on 183 GHz water vapor line are ideal for over-land retrievals.

  5. Preparation, cytotoxicity, and in vivo antitumor efficacy of 111In-labeled modular nanotransporters

    Science.gov (United States)

    Slastnikova, Tatiana A; Rosenkranz, Andrey A; Morozova, Natalia B; Vorontsova, Maria S; Petriev, Vasiliy M; Lupanova, Tatiana N; Ulasov, Alexey V; Zalutsky, Michael R; Yakubovskaya, Raisa I; Sobolev, Alexander S

    2017-01-01

    Purpose Modular nanotransporters (MNTs) are a polyfunctional platform designed to achieve receptor-specific delivery of short-range therapeutics into the cell nucleus by receptor-mediated endocytosis, endosome escape, and targeted nuclear transport. This study evaluated the potential utility of the MNT platform in tandem with Auger electron emitting 111In for cancer therapy. Methods Three MNTs developed to target either melanocortin receptor-1 (MC1R), folate receptor (FR), or epidermal growth factor receptor (EGFR) that are overexpressed on cancer cells were modified with p-SCN-Bn-NOTA and then labeled with 111In in high specific activity. Cytotoxicity of the 111In-labeled MNTs was evaluated on cancer cell lines bearing the appropriate receptor target (FR: HeLa, SK-OV-3; EGFR: A431, U87MG.wtEGFR; and MC1R: B16-F1). In vivo micro-single-photon emission computed tomography/computed tomography imaging and antitumor efficacy studies were performed with intratumoral injection of MC1R-targeted 111In-labeled MNT in B16-F1 melanoma tumor-bearing mice. Results The three NOTA-MNT conjugates were labeled with a specific activity of 2.7 GBq/mg with nearly 100% yield, allowing use without subsequent purification. The cytotoxicity of 111In delivered by these MNTs was greatly enhanced on receptor-expressing cancer cells compared with 111In nontargeted control. In mice with B16-F1 tumors, prolonged retention of 111In by serial imaging and significant tumor growth delay (82% growth inhibition) were found. Conclusion The specific in vitro cytotoxicity, prolonged tumor retention, and therapeutic efficacy of MC1R-targeted 111In-NOTA–MNT suggest that this Auger electron emitting conjugate warrants further evaluation as a locally delivered radiotherapeutic, such as for ocular melanoma brachytherapy. Moreover, the high cytotoxicity observed with FR- and EGFR-targeted 111In-NOTA–MNT suggests further applications of the MNT delivery strategy should be explored. PMID:28138237

  6. Preparation and analysis of deuterium-labeled aspirin: application to pharmacokinetic studies

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, A.K.; FitzGerald, G.A.

    1985-02-01

    Inhibition of endogenous prostacyclin and thromboxane biosynthesis by aspirin is critically dose-dependent in humans. Gastrointestinal and hepatic hydrolysis may limit systemic availability of aspirin, especially in low doses, perhaps contributing to the biochemical selectivity of aspirin. Existing analytical methods do not permit determination of systemic bioavailability when low (less than 100 mg) doses of aspirin are administered. Deuterium-labeled aspirin (2-acetoxy(3,4,5,6-/sup 2/H4)benzoic acid) was synthesized from salicylic acid by catalytic exchange and subsequent acetylation. Analysis of the compounds as benzyl esters by GC-MS followed extractive alkylation from plasma. Heptadeuterated compounds were used as internal standards. Simultaneous administration of tetradeuterated aspirin intravenously with native aspirin orally to anesthetized dogs permitted kinetic studies of both aspirin and salicylic acid. The sensitivity of the method is superior to published methods using HPLC and, thus, more applicable to studies of low dose aspirin. Pulse administration of stable isotope-labeled aspirin permits detailed and repeated studies of dose-related aspirin pharmacokinetics in humans.

  7. Digital Array Gas Radiometer (DAGR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation proposed here is a digital array gas radiometer (DAGR), a new design for a gas filter correlation radiometer (GFCR) to accurately measure and monitor...

  8. Laboratory panel and radiometer calibration

    CSIR Research Space (South Africa)

    Deadman, AJ

    2011-07-01

    Full Text Available AND RADIOMETER CALIBRATION A.J Deadmana, I.D Behnerta, N.P Foxa, D. Griffithb aNational Physical Laboratory (NPL), United Kingdom bCouncil for Scientific and Industrial Research (CSIR), South Africa ABSTRACT This paper presents the results...

  9. General method of preparation of uniformly {sup 13}C, {sup 15}N-labeled DNA fragments for NMR analysis of DNA structures

    Energy Technology Data Exchange (ETDEWEB)

    Rene, Brigitte; Masliah, Gregoire; Zargarian, Loussine; Mauffret, Olivier; Fermandjian, Serge [UMR 8113 CNRS - LBPA Ecole Normale Superieure de Cachan, Institut Gustave Roussy, Departement de Biologie et Pharmacologie Structurales (France)], E-mail: sfermand@igr.fr

    2006-11-15

    Summary{sup 13}C, {sup 15}N labeling of biomolecules allows easier assignments of NMR resonances and provides a larger number of NMR parameters, which greatly improves the quality of DNA structures. However, there is no general DNA-labeling procedure, like those employed for proteins and RNAs. Here, we describe a general and widely applicable approach designed for preparation of isotopically labeled DNA fragments that can be used for NMR studies. The procedure is based on the PCR amplification of oligonucleotides in the presence of labeled deoxynucleotides triphosphates. It allows great flexibility thanks to insertion of a short DNA sequence (linker) between two repeats of DNA sequence to study. Size and sequence of the linker are designed as to create restriction sites at the junctions with DNA of interest. DNA duplex with desired sequence and size is released upon enzymatic digestion of the PCR product. The suitability of the procedure is validated through the preparation of two biological relevant DNA fragments.

  10. Preparation and application of new fluorescein-labeled fumonisins B1 in fluorescence polarization analysis technique

    Science.gov (United States)

    Objective: To prepare a new fluorescent tracer against common mycotoxins such as fumonisin B1 in order to replace 6-(4,6-Dichlorotriazinyl) aminofluorescein (6-DTAF), an expensive marker, and to develop a technique for quick detection of fumonisin B1 based on the principle of fluorescence polarizati...

  11. Microwave Radiometer Linearity Measured by Simple Means

    DEFF Research Database (Denmark)

    Skou, Niels

    2002-01-01

    Modern spaceborne radiometer systems feature an almost perfect on-board calibration, hence the primary calibration task to be carried out before launch is a check of radiometer linearity. This paper describes two ways of measuring linearity of microwave radiometers only requiring relatively simple...

  12. Microwave Radiometer Systems, Design and Analysis

    DEFF Research Database (Denmark)

    Skou, Niels; Vine, David Le

    Two important microwave remote sensors are the radar and the radiometer. There have been a number of books written on various aspects of radar, but there have been only a few written on microwave radiometers, especially on subjects of how to design and build radiometer systems. This book, which...

  13. Microwave Radiometer Systems, Design and Analysis

    DEFF Research Database (Denmark)

    Skou, Niels; Vine, David Le

    Two important microwave remote sensors are the radar and the radiometer. There have been a number of books written on various aspects of radar, but there have been only a few written on microwave radiometers, especially on subjects of how to design and build radiometer systems. This book, which...

  14. Preparation and biological evaluation of 99Tcm-labelled fatty acids

    Institute of Scientific and Technical Information of China (English)

    LIANG Jixin; HU Ji; CHEN Baojun; LUO Lianzhe; LI Hongyu; SHEN Langtao; LUO Zhifu

    2007-01-01

    The aim of the present work was to develop radiolabelling fatty acids based on 99Tcm carbonyl chemistry for heart imaging. Undecanoic acids functionalised with iminodiacetatic acid and cysteine were radiolabelled with [99Tcm (CO)3(H2O)3]+ intermediates, and their radiolabelling conditions were carefully studied. Biodistribution of 99Tcm (CO)3-CYST FAC11 and 99Tcm (CO)3-IDA FAC11 were observed in normal mice. The results showed that two 99Tcm-labelled compounds had similar profile in terms of high initial radioactivity uptake and rapid washout of radiotracers in the heart. 99Tcm (CO)3-IDA FAC11 was mainly excreted via hepatobiliary system in contrast to 99Tcm (CO)3-CYST FAC11, which was excreted from urinary system. It may be in part attributed to the more lipophilicity of 99Tcm (CO)3-IDA FAC11 than 99Tcm (CO)3-CYST FAC11.

  15. Preparation, cytotoxicity, and in vivo antitumor efficacy of 111In-labeled modular nanotransporters

    Directory of Open Access Journals (Sweden)

    Slastnikova TA

    2017-01-01

    Full Text Available Tatiana A Slastnikova,1,* Andrey A Rosenkranz,1,2,* Natalia B Morozova,3 Maria S Vorontsova,3 Vasiliy M Petriev,4,5 Tatiana N Lupanova,1 Alexey V Ulasov,1 Michael R Zalutsky,6 Raisa I Yakubovskaya,3 Alexander S Sobolev1,2 1Laboratory of Molecular Genetics of Intracellular Transport, Institute of Gene Biology, Russian Academy of Sciences, 2Department of Biophysics, Biological Faculty, Lomonosov Moscow State University, 3Department of Anticancer Therapy Modifiers and Protectors, Moscow Hertsen Research Institute of Oncology, Russian Ministry of Health Care, Moscow, 4National Medical Research Radiological Center, Russian Ministry of Health Care, Obninsk, Moscow Region, 5Department of Nuclear Medicine, National Research Nuclear University MEPhI (Moscow Engineering Physics Institute, Moscow, Russia; 6Department of Radiology, Duke University Medical Center, Durham, NC, USA *These authors contributed equally to this work Purpose: Modular nanotransporters (MNTs are a polyfunctional platform designed to achieve receptor-specific delivery of short-range therapeutics into the cell nucleus by receptor-mediated endocytosis, endosome escape, and targeted nuclear transport. This study evaluated the potential utility of the MNT platform in tandem with Auger electron emitting 111In for cancer therapy.Methods: Three MNTs developed to target either melanocortin receptor-1 (MC1R, folate receptor (FR, or epidermal growth factor receptor (EGFR that are overexpressed on cancer cells were modified with p-SCN-Bn-NOTA and then labeled with 111In in high specific activity. Cytotoxicity of the 111In-labeled MNTs was evaluated on cancer cell lines bearing the appropriate receptor target (FR: HeLa, SK-OV-3; EGFR: A431, U87MG.wtEGFR; and MC1R: B16-F1. In vivo micro-single-photon emission computed tomography/computed tomography imaging and antitumor efficacy studies were performed with intratumoral injection of MC1R-targeted 111In-labeled MNT in B16-F1 melanoma tumor

  16. Preparation and evaluation of radio labelled recombinant human interleukin 2 by improved chloramine T method

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Masahiro; Kominami, Goro; Kono, Masao (Shionogi and Co. Ltd., Osaka (Japan). Research Lab.)

    1991-03-01

    Iodination by improved chloramine T method was investigated. Iodine was activated with very small quantity of chloramine T (21 fold excess to iodine in molar ratio) and then recombinant interleukin-2 (rIL-2) was added to the mixture. Characteristics of the labelled rIL-2 after purification by reversed-phase HPLC was superior to those by usual chloramine T method or lactoperoxidase method. The specific activity was 0.74-1.11 MBq/{mu}g and the immunoreactivity, biological activity and binding ability to rIL-2 receptors were similar to the intrinsic rIL-2. The improved chloramine T method is useful for iodination of unstable peptides and proteins. (author).

  17. Preparation and in vivo evaluation of novel linkers for {sup 211}At labeling of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Talanov, Vladimir S. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Yordanov, Alexander T. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Garmestani, Kayhan [Metabolism Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Milenic, Diane E. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Arora, Hans C. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Plascjak, Paul S. [Department of Nuclear Medicine, Clinical Center, National Institutes of Health, Bethesda, MD 20892 (United States); Eckelman, William C. [Department of Nuclear Medicine, Clinical Center, National Institutes of Health, Bethesda, MD 20892 (United States); Waldmann, Thomas A. [Metabolism Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Brechbiel, Martin W. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States)]. E-mail: martinwb@mail.nih.gov

    2004-11-01

    The syntheses, radiolabeling, antibody conjugation and in vivo evaluation of new linkers for {sup 211}At labeling of monoclonal antibodies are described. Syntheses of the N-succinimidyl esters and labeling with {sup 211}At to form succinimidyl 4-methoxymethyl-3-[{sup 211}At]astatobenzoate (9) and succinimidyl 4-methylthiomethyl-3-[{sup 211}At]astatobenzoate (11) from the corresponding bromo-aryl esters is reported. Previously reported succinimidyl N-{l_brace}4-[{sup 211}At]astatophenethyl{r_brace}succinamate (SAPS) is employed as a standard of in vivo stability. Each agent is conjugated with Herceptin in parallel with their respective {sup 125}I analogue, succinimidyl 4-methoxymethyl-3-[{sup 125}I]iodobenzoate (10), succinimidyl 4-methylthiomethyl-3-[{sup 125}I]iodobenzoate (12) and succinimidyl N-{l_brace}4-[{sup 125}I]iodophenethyl{r_brace}succinamate (SIPS), respectively, for comparative assessment in LS-174T xenograft-bearing mice. With 9 and 11, inclusion of an electron pair donor in the ortho position does not appear to provide in vivo stability comparable to SAPS. Variables in radiolabeling chemistry of these three agents with {sup 211}At are notable. Sequential elimination of acetic acid and oxidizing agent, N-chlorosuccinimide (NCS), from the {sup 211}At radiolabeling protocol for forming SAPS improves yield, product purity and consistency. NCS appears to be critical for the radiolabeling of 6 with {sup 211}At. Formation of 11, however, is found to require the absence of NCS. Elimination of acetic acid is found to have no effect on radiolabeling efficiency or yield for either of these reactions.

  18. Reduction of β-radiation exposure during preparation of 188Re-labelled Lipiodol for hepatocellular carcinoma treatment.

    Science.gov (United States)

    Lepareur, Nicolas; Laffont, Sophie; Ardisson, Valérie; Noiret, Nicolas; Garin, Etienne

    2012-02-01

    Rhenium-188 (188Re) is of widespread interest for treating various diseases because of its attractive physical and chemical properties. The routine preparation of therapeutic doses of 188Re-labelled tracers can result in significant radiation exposure to the operator. We studied the impact of automating the preparation of 188Re-Lipiodol on the radiochemist's exposure, as well as the importance of the model of syringe shielding. To monitor radiation exposure continuously readable electronic personal dosimeters were used. Thermoluminescence dosimeters were fixed to the probable most exposed fingers of the radiochemist during preparation of the radiotracer and during the syringing. Dose rates were measured using a Babyline. Automation of the synthesis reduced personal dose equivalents from 2.60±4.35 to 1.61±1.20 µSv/GBq [Hp(10)] and from 38.37±55.28 to 21.84±16.14 µSv/GBq [Hp(0.07)]. Dose to the extremities was also reduced (-80% for the right hand; -58% for the left one). The Lemer-Pax PSWG syringe shield led to a slightly lower dose to the hands compared with the Medisystem (1.1±0.27 vs. 1.34±0.6 mSv/GBq for the right finger). Automation of the synthesis leads to a significant decrease in radiation exposure to the operator. The Lemer-Pax PSWG syringe shield provides better hand protection than the smaller Medisystem Mediclic.

  19. Preparation of liposome-coated oligonucleotide labeled with 99mTc and its uptake in vascular smooth muscle cells

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    To explore the preparation method of liposome-coated 99mTc-labeled antisense oligonucleotide (ASON),targeteing the proliferating cell nuclear antigen (PCNA), and to explore the biological characteristics and the uptake kinetics of a radiolabeled probe in vascular smooth muscle cells, an 18-base single-stranded antisense oligonucleotide targeting PCNA mRNA and the complementary strand (sense oligonucleotide, SON) were synthesized. The ASON (SON) was labeled with 99mTc, by conjugating the bifunctional chelator (hydrazino nicotinamide, HYNIC), and purified through a gel filtration column of Sephadex G-25. The product was then encapsulated in cationic liposome (oligofectamineTM). The radiolabeling efficiency, radiochemical purity, stability of the liposome-coated 99mTc-HYNIC-ASON in a phosphate buffered solution (PBS), and fresh human serum and its uptake rate were studied. There was no significant difference between the 99mTc radiolabeling efficiencies of HYNIC-ASON and HYNIC-SON, which were 60.04% ± 1.92% and 59.60% ± 2.53%, respectively (P > 0.05, n = 5). The radiochemical purity of the liposome-coated 99mTc-HYNIC-ASON was 94.70% ± 1.90% (n = 5). And after incubation with PBS and fresh human seAt 90 min after transfection, the uptake rate of the liposome-coated 99mTc-HYNIC-ASON reached its peak of 83.8% ±5.92% in vascular smooth muscle cells (VSMCs) and was much higher than that of the nonliposome-coated 99mTc-HYNIC-ASON, which was 11.16% ± 0.54% (P < 0.01, n = 4). The labeling method of PCNA ASON (SON) conjugated by HYNIC has been proved successful. The liposome was able to enhance the ASON (SON) uptake in VSMCs,and could be widely used as a safe, convenient, effective gene transfer carrier.

  20. Separation and formation of ryanodine from dehydroryanodine. Preparation of tritium-labelled ryanodine

    Energy Technology Data Exchange (ETDEWEB)

    Sutko, J.L.; Thompson, L.J.; Schlatterer, R.G. and others

    1986-02-01

    The commercially available preparation of the naturally occurring diterpene ester ryanodine contains several compounds in addition to ryanodine. These compounds were separated and purified using high performance liquid chromatography. The two major components, ryanodine and dehydroryanodine represented 90% of the material present. A method for the efficient reduction of dehydroryanodine to ryanodine was developed and used to produce ryanodine having tritium atoms at positions 19 and 20 and a specific activity of 60.8 Ci/mmole.

  1. Preparation and biodistribution of copper-67-labeled porphyrins and porphyrin-A6H immunoconjugates

    Energy Technology Data Exchange (ETDEWEB)

    Bhalgat, Mahesh K.; Roberts, Jeanette C.; Mercer-Smith, Janet A.; Knotts, Brenda D.; Vessella, Robert L.; Lavallee, David K

    1997-02-01

    The synthetic porphyrins, N-benzyl-5,10,15,20-tetrakis (4-carboxyphenyl)porphine (N-bzHTCPP) and N-4-nitrobenzyl-5-(4-carboxyphenyl)-10,15,20-tris(4-sulfophenyl)porphine (N-bzHCS{sub 3}P), represent excellent radiocopper chelating agents that may find utility in antibody-mediated diagnosis and/or therapy. N-bzHCS{sub 3}P was conjugated to an anti-renal cell carcinoma (RCC) antibody, A6H, and labeled with copper-67. {sup 67}CuCS{sub 3}P-A6H was studied for its biodistribution in human RCC xenograft-bearing nude mice, along with the radiolabeled free porphyrins. The porphyrins resulted in tumor:blood ratios in the range of 3 to 4 after 48 h. The radiolabeled antibody achieved a tumor:blood ratio of over 16 after 45 h, indicating accumulation at the desired site. However, unwanted localization also occurred in the liver and spleen, which will have to be rectified before realizing the full potential of this approach.

  2. TEMPEST-D MM-Wave Radiometer

    Science.gov (United States)

    Padmanabhan, S.; Gaier, T.; Reising, S. C.; Lim, B.; Stachnik, R. A.; Jarnot, R.; Berg, W. K.; Kummerow, C. D.; Chandrasekar, V.

    2016-12-01

    The TEMPEST-D radiometer is a five-frequency millimeter-wave radiometer at 89, 165, 176, 180, and 182 GHz. The direct-detection architecture of the radiometer reduces its power consumption and eliminates the need for a local oscillator, reducing complexity. The Instrument includes a blackbody calibrator and a scanning reflector, which enable precision calibration and cross-track scanning. The MMIC-based millimeter-wave radiometers take advantage of the technology developed under extensive investment by the NASA Earth Science Technology Office (ESTO). The five-frequency millimeter-wave radiometer is built by Jet Propulsion Laboratory (JPL), which has produced a number of state-of-the-art spaceborne microwave radiometers, such as the Microwave Limb Sounder (MLS), Advanced Microwave Radiometer (AMR) for Jason-2/OSTM, Jason-3, and the Juno Microwave Radiometer (MWR). The TEMPEST-D Instrument design is based on a 165 to 182 GHz radiometer design inherited from RACE and an 89 GHz receiver developed under the ESTO ACT-08 and IIP-10 programs at Colorado State University (CSU) and JPL. The TEMPEST reflector scan and calibration methodology is adapted from the Advanced Technology Microwave Sounder (ATMS) and has been validated on the Global Hawk unmanned aerial vehicle (UAV) using the High Altitude MMIC Sounding radiometer (HAMSR) instrument. This presentation will focus on the design, development and performance of the TEMPEST-D radiometer instrument. The flow-down of the TEMPEST-D mission objectives to instrument level requirements will also be discussed.

  3. Silica coating of luminescent quantum dots prepared in aqueous media for cellular labeling

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yunfei; Li, Yan, E-mail: yli@ecust.edu.cn; Zhong, Xinhua, E-mail: zhongxh@ecust.edu.cn

    2014-12-15

    Graphical abstract: A facile route based on modified Stöber method was used for the synthesis of silica coated QDs (QD@SiO{sub 2}) starting from aqueously prepared CdTe/CdS QDs. The resultant QD@SiO{sub 2} exhibited a significant increase in emission efficiency compared with that of the initial QDs, along with a small size (∼5 nm in diameter), great stability and low cytotoxicity, which makes it a good candidate as robust biomarker. - Highlights: • We present a facile modified Stöber method to prepare highly luminescent QD@SiO{sub 2}. • The PL efficiency of QDs increases significantly after silica coating. • QD@SiO{sub 2} exhibits small size (∼5 nm) and great dispersibility in aqueous solution. • QD@SiO{sub 2} presents extraordinary photo and colloidal stability. • The silica shell eliminates QD cytotoxicity, providing the access of bioconjugation. - Abstract: Silica coating is an effective approach for rendering luminescent quantum dots (QDs) with water dispersibility and biocompatibility. However, it is still challenging to prepare silica-coated QDs (QD@SiO{sub 2}) with high emission efficiency, small size and great stability in favor for bioapplication. Herein, we reported a modified Stöber method for silica coating of aqueously-prepared CdTe/CdS QDs. With the coexistence of Cd{sup 2+} and thioglycolic acid (TGA), a thin silica shell was formed around QDs by the hydrolysis of tetraethyl orthosilicate (TEOS). The resultant QD@SiO{sub 2} with a small size (∼5 nm in diameter) exhibits significantly higher emission efficiencies than that of the initial QDs. Also, QD@SiO{sub 2} has extraordinary photo and colloidal stability (pH range of 5–13, 4.0 M NaCl solution). Protected by the silica shell, the cytotoxicity of QDs could be reduced. Moreover, the QD@SiO{sub 2} conjugated with folic acid (FA) presents high specific binding toward receptor-positive HeLa cells over receptor-negative A549 cells.

  4. Cloud Top Scanning radiometer (CTS)

    Science.gov (United States)

    1978-01-01

    A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.

  5. Improved synthesis of anti-[18F]FACBC: improved preparation of labeling precursor and automated radiosynthesis.

    Science.gov (United States)

    McConathy, Jonathan; Voll, Ronald J; Yu, Weiping; Crowe, Ronald J; Goodman, Mark M

    2003-06-01

    The non-natural amino acid anti-1-amino-3-[18F]fluorocyclobutyl-1-carboxylic acid (FACBC) has shown promise for tumor imaging with positron emission tomography. An improved synthesis of the precursor of anti-[18F]FACBC has been devised which demonstrates high stereoselectivity and suitability for large-scale preparations. An automated radiosynthesis has been developed which provides anti-[18F]FACBC in 24% decay-corrected yield. Additionally, the major non-radioactive species present in doses of anti-[18F]FACBC has been identified as anti-1-amino-3-hydroxycyclobutane-1-carboxylic acid. Together, these results are important steps towards the routine production of anti-[18F]FACBC for human use.

  6. Biological evaluation of two iodine-123-labeled D-glucose acetals prepared as glucose transporter radioligands

    Energy Technology Data Exchange (ETDEWEB)

    Brunet-Desruet, Marie-Dominique; Ghezzi, Catherine; Morin, Christophe; Comet, Michel; Fagret, Daniel

    1998-07-01

    Two iodinated acetals of D-glucose, 4,6-(R)-O-(2'-iodoethylidene)-{alpha}, {beta}-D-glucose and 4,6-(R)-O-(4'-iodobenzylidene)-{alpha}, {beta}-D-glucose , were prepared and their potential as suitable SPECT radioligands for imaging of glucose transporters was studied. Both are analogs of acetal D-glucose derivatives, which are known to bind to the exofacial sites of the glucose transport protein (GluT). To assess whether iodinated acetals 1 and 2 interacted with the glucose transporter, they were tested in vitro in human erythrocytes (GluT1) and neonatal rat cardiomyocytes (GluT4). The results indicated that 1 and 2 had a very low affinity for the glucose transporter and probably accumulated in cells. Study of their tissue distribution was carried out in the mouse in vivo: Both compounds showed fast tissue clearance with preferential renal elimination. It is concluded that iodinated acetals of D-glucose 1 and 2 are not suitable for GluT targeting in vivo.

  7. Preparation and bioevaluation of {sup 177}Lu-labelled anti-CD44 for radioimmunotherapy of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Young; Hong, Young Don; Jung, Sung Hee; Choi, Sun Ju [Radioisotope Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-12-15

    CD44 is a particular adhesion molecule and facilitates both cell-cell and cell-matrix interactions. In particular, splice variants of CD44 are particularly overexpressed in a large number of malignancies and carcinomas. In this study, the {sup 177}Lu-labelled CD44 targeting antibody was prepared and bioevaluated in vitro and in vivo. Anti-CD44 was immunoconjugated with the equivalent molar ratio of cysteine-based dtPA-ncS and radioimmunoconjugated with {sup 177}Lu at room temperature within 15 minutes. the stability was tested in human serum. An in vitro study was carried out in Ht-29 human colon cancer cell lines. For the biodistribution study {sup 177}Lu-labelled anti-CD44 was injected in xenograft mice. Anti-CD44 was immunoconjugated with cysteinebased dtPA-ncS and purified by a centricon filter system having a molecular cut-off of 50 kda. radioimmunoconjugation with {sup 177}Lu was reacted for 15 min at room temperature. the radiolabeling yield was >99%, and it was stable in human serum without any fragmentation or degradation. The radioimmunoconjugate showed a high binding affinity on HT-29 colon cancer cell surfaces. In a biodistribution study, the tumor-to-blood ratio of the radioimmunoconjugate was 43 : 1 at 1 day post injection (p.i) in human colon cancer bearing mice. the anti-CD44 monoclonal antibody for the targeting of colon cancer was effectively radioimmunoconjugated with {sup 177}Lu. the in vitro high immunoactivity of this radioimmunoconjugate was determined by a cell binding assay. In addition, the antibody's tumor targeting ability was demonstrated with very high uptake in tumors. this radioimmunoconjugate is applicable to therapy in human colon cancer with highly expressed CD44.

  8. Use of Take-set system for radiopharmaceutical labelling: example of indium-111 labeled pentetreotide (Octreoscan) preparation; Utilisation du systeme Take-set pour le radiomarquage des medicaments radiopharmaceutiques: exemple de la preparation du pentetreotide marque a l'indium 111 (Octreoscan)

    Energy Technology Data Exchange (ETDEWEB)

    Ben Reguiga, M.; Sinegre, M. [Hopital Beaujon, Unite de Radiopharmacie, Service de Pharmacie-toxicologie, 92 - Clichy (France); Besse, H.; Stievenart, J.L.; Le Guludec, D. [Hopital Beaujon, Service de Medecine Nucleaire92 - Clichy (France)

    2009-09-15

    The quality of indium 111 radiolabelled pentetreotide preparation (Octreoscan, Covidien) depends on several factors among which the use of a special transfer needle (Sterican) especially conceived to avoid the metal impurities introduction into the reactional medium during labelling. This device, usually provided by the supplier, can exceptionally present defects (twisted needle, folded bevel...) preventing its use for the preparation. In order to manage this risk, we propose in the present technical note an alternative labelling method, based on an adaptation of the original one and using another transfer device, the Take-setSWAN system, which permits to obtain high quality Octreoscan preparations that meet the product approval specifications. (authors)

  9. Preparation of ⁶⁸Ga-labelled DOTA-peptides using a manual labelling approach for small-animal PET imaging.

    Science.gov (United States)

    Romero, Eduardo; Martínez, Alfonso; Oteo, Marta; García, Angel; Morcillo, Miguel Angel

    2016-01-01

    (68)Ga-DOTA-peptides are a promising PET radiotracers used in the detection of different tumours types due to their ability for binding specifically receptors overexpressed in these. Furthermore, (68)Ga can be produced by a (68)Ge/(68)Ga generator on site which is a very good alternative to cyclotron-based PET isotopes. Here, we describe a manual labelling approach for the synthesis of (68)Ga-labelled DOTA-peptides based on concentration and purification of the commercial (68)Ga/(68)Ga generator eluate using an anion exchange-cartridge. (68)Ga-DOTA-TATE was used to image a pheochromocytoma xenograft mouse model by a microPET/CT scanner. The method described provides satisfactory results, allowing the subsequent (68)Ga use to label DOTA-peptides. The simplicity of the method along with its implementation reduced cost, makes it useful in preclinical PET studies.

  10. Research of MMW radiometer virtual prototyping technology

    Institute of Scientific and Technical Information of China (English)

    Fan Qinghui; Li Xingguo; Zhang Guangfeng

    2008-01-01

    The idea of millimeter-wave (MMW) radiometer virtual prototyping is discussed in this paper. Designing en-vironment, designing method and the main modeling components of virtual MMW radiometer are researched. Important external parameters, which have significant influence to composing system, are used to components modeling, and then components are taken to buildup virtual MMW radiometer system. Moreover, the effect to output is contrasted whether there is a low-noise amplifier or not.

  11. Sky Radiometers on Stand for Downwelling Radiation

    Data.gov (United States)

    Oak Ridge National Laboratory — The Sky Radiation (SKYRAD) collection of radiometers provides each Atmospheric Radiation and Cloud Station (ARCS) with continuous measurements of broadband shortwave...

  12. Microwave Radiometry and Radiometers for Ocean Applications

    DEFF Research Database (Denmark)

    Skou, Niels

    2008-01-01

    The microwave radiometer system measures, within its bandwidth, the naturally emitted radiation – the brightness temperature – of substances within its antenna’s field of view. Thus a radiometer is really a sensitive and calibrated microwave receiver. The radiometer can be a basic total power...... aperture radiometer technique, both yielding imaging capability without scanning. Typical applications of microwave radiometry concerning oceans are: sea salinity, sea surface temperature, wind speed and direction, sea ice detection and classification. However, in an attempt to measure properties...

  13. Millimeter-Wave Radiometer Imager

    Science.gov (United States)

    Wilson, W. J.; Howard, R. J.; Ibbott, A. C.; Parks, G. S.; Ricketts, W. B.

    1988-01-01

    A 3-mm radiometer system with mechanically scanned antenna built for use on small aircraft or helicopter to produce near-real-time moderate-resolution images of ground. Main advantage of passive imaging sensor able to provide information through clouds, smoke, and dust when visual and infrared (IR) systems unusable. Used also for variety of remote-sensing applications such as measurements of surface moisture, snow cover, vegetation type and extent, mineral type and extent, surface temperature, and thermal inertia. Possible to map fires and volcanic lava flows through obscuring clouds and smoke.

  14. Filter-aided sample preparation with dimethyl labeling to identify and quantify milk fat globule membrane proteins.

    Science.gov (United States)

    Lu, Jing; Boeren, S; de Vries, S C; van Valenberg, H J F; Vervoort, J; Hettinga, K

    2011-12-10

    Bovine milk is a major nutrient source in many countries and it is produced at an industrial scale. Milk is a complex mixture of proteins, fats, carbohydrates, vitamins and minerals. The composition of the bovine milk samples can vary depending on the genetic makeup of the bovine species as well as environmental factors. It is therefore important to study the qualitative and quantitative differences of bovine milk samples. Proteins in milk can be present in casein micelles, in the serum (the water soluble fraction) or in fat globules. These fat globules have a double membrane layer with proteins being bound to or being incapsulated in the membrane layer. The identification and molecular composition of the milk proteins have gained increased interest in recent years. Proteomic techniques make it now possible to identify up to many thousands of proteins in one sample, however quantification of proteins is as yet not straightforward. We analyzed the proteins of the milk fat globule membrane using dimethyl labeling methods combined with a filter-aided sample preparation protocol. Using these methods, it is now possible to quantitatively study the detailed protein composition of many milk samples in a short period of time. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. On the chemistry of Ingenol. Pt. 5. Preparation of tritium-labeled 3-O-tetradecanoylingenol ([2O-[sup 3]H]-3-TI)

    Energy Technology Data Exchange (ETDEWEB)

    Roeser, H.; Sorg, B.; Hecker, E. (Inst. of Biochemistry, Deutsches Krebsforschungszentrum, Heidelberg (Germany))

    1992-07-01

    Tritium-labeling of the ingenol monoester 3-O-tetradecanoylingenol (3-TI), the prototype tumor promoter of the ingenane type diterpene esters, is described. The preparation starts with oxidation of 3-TI by manganese dioxide to yield 3-TI-20-aldehyde which is reduced by [[sup 3]H]-sodium borohydride in the presence of equimolar amounts of cerium trichloride hexahydrate to give [20-[sup 3]H]-3-TI. The labeled promoter is obtained in 42% overall yield with a specific radioactivity of 15.8 Ci/mmol. (orig.).

  16. Evaluation of indium-111-2-mercaptopyridine-N-oxide for labeling leukocytes in plasma: a kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Thakur, M.L.; McKenney, S.L.; Park, C.H.

    1985-05-01

    Pure neutrophils, lymphocytes, and mixed leukocytes have been labeled in vitro with /sup 111/In chelated to a nontoxic, water soluble agent 2-mercaptopyridine-N-oxide (Merc). Cells were labeled in isotonic salt-balanced medium with preformed (/sup 111/In)Merc, or in 0.5 ml autologous plasma by incubation with dry Merc first and then with /sup 111/In. The latter method facilitated a kit procedure that required 2 ..mu..g dry Merc when acid citrate dextrose was used as anticoagulant or 20..mu..g when heparin was used. Labeling efficiency was dependent on cell concentration and pH. Labeled cells accumulated avidly in experimental abscesses. In dogs, the liver uptake of labeled cells was only 18.8% compared to that of 48.5% when cells were labeled with (/sup 111/In) oxine.

  17. Measuring the instrument function of radiometers

    Energy Technology Data Exchange (ETDEWEB)

    Winston, R. [Univ. of Chicago, IL (United States); Littlejohn, R.G. [Univ. of California, Berkeley, CA (United States)

    1997-12-31

    The instrument function is a function of position and angle, the knowledge of which allows one to compute the response of a radiometer to an incident wave field in any state of coherence. The instrument function of a given radiometer need not be calculated; instead, it may be measured by calibration with incident plane waves.

  18. Preparation and in vivo evaluation of a novel stabilized linker for {sup 211}At labeling of protein

    Energy Technology Data Exchange (ETDEWEB)

    Talanov, Vladimir S. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States)]. E-mail: vstalanov@msrce.howard.edu; Garmestani, Kayhan [Metabolism Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Regino, Celeste A.S. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Milenic, Diane E. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Plascjak, Paul S. [Department of Nuclear Medicine, Clinical Center, National Institutes of Health, Bethesda, MD 20892 (United States); Waldmann, Thomas A. [Metabolism Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States); Brechbiel, Martin W. [Radiation Oncology Branch, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892 (United States)]. E-mail: martinwb@mail.nih.gov

    2006-05-15

    Significant improvement of in vivo stability of {sup 211}At-labeled radioimmunoconjugates achieved upon employment of a recently reported new linker, succinimidyl N-2-(4-[{sup 211}At]astatophenethyl)succinamate (SAPS), prompted additional studies of its chemistry. The {sup 211}At radiolabeling of succinimidyl N-2-(4-tributylstannylphenethyl)succinamate (1) was noted to decline after storage at -15{sup o}C for greater than 6 months. Compound 1 was found to degrade via a ring closure reaction with the formation of N-2-(4-tributylstannylphenethyl)succinimide (3), and a modified procedure for the preparation of 1 was developed. The N-methyl structural analog of 1, succinimidyl N-2-(4-tributylstannylphenethyl)-N-methyl succinamate (SPEMS), was synthesized to investigate the possibility of improving the stability of reagent-protein linkage chemistry. Radiolabeling of SPEMS with {sup 211}At generates succinimidyl N-2-(4-[{sup 211}At]astatophenethyl)-N-methyl succinamate (Methyl-SAPS), with yields being consistent for greater than 1 year. Radiolabelings of 1 and SPEMS with {sup 125}I generated succinimidyl N-2-(4-[{sup 125}I]iodophenethyl)succinamate (SIPS) and succinimidyl N-2-(4-[{sup 125}I]iodophenethyl)-N-methyl succinamate (Methyl-SIPS), respectively, and showed no decline in yields. Methyl-SAPS, SAPS, Methyl-SIPS and SIPS were conjugated to Herceptin for a comparative assessment in LS-174T xenograft-bearing mice. The conjugates of Herceptin with Methyl-SAPS or Methyl-SIPS demonstrated immunoreactivity equivalent to if not superior to the SAPS and SIPS paired analogs. The in vivo studies also revealed that the N-methyl modification resulted in a superior statinated product.

  19. Zinc Phthalocyanine Labelled Polyethylene Glycol: Preparation, Characterization, Interaction with Bovine Serum Albumin and Near Infrared Fluorescence Imaging in Vivo

    Directory of Open Access Journals (Sweden)

    Tianjun Liu

    2012-05-01

    Full Text Available Zinc phthalocyanine labelled polyethylene glycol was prepared to track and monitor the in vivo fate of polyethylene glycol. The chemical structures were characterized by nuclear magnetic resonance and infrared spectroscopy. Their light stability and fluorescence quantum yield were evaluated by UV-Visible and fluorescence spectroscopy methods. The interaction of zinc phthalocyanine labelled polyethylene glycol with bovine serum albumin was evaluated by fluorescence titration and isothermal titration calorimetry methods. Optical imaging in vivo, organ aggregation as well as distribution of fluorescence experiments for tracking polyethylene glycol were performed with zinc phthalocyanine labelled polyethylene glycol as fluorescent agent. Results show that zinc phthalocyanine labelled polyethylene glycol has good optical stability and high emission ability in the near infrared region. Imaging results demonstrate that zinc phthalocyanine labelled polyethylene glycol can track and monitor the in vivo process by near infrared fluorescence imaging, which implies its potential in biomaterials evaluation in vivo by a real-time noninvasive method.

  20. A Scanning Microwave Radar and Radiometer

    DEFF Research Database (Denmark)

    Skou, Niels

    1995-01-01

    The Scanning Microwave Radar and Radiometer (SMRR) is a line scanner featuring a combined radar and radiometer system operating around 35 and 94 GHz. The layout of the SMRR is shown. The 2 offset antenna parabolas scan in synchronism, the receiver antenna has the highest gain in order to ensure...... that footprints are identical for the radar and the radiometer. The instrument will be flown in a pod under a Gulfstream G3 normally cruising with 240 m/sec at 12500 m, and will thus be able to sense clouds and precipitation from above...

  1. Microwave Radiometer for Aviation Safety Project

    Data.gov (United States)

    National Aeronautics and Space Administration — SBIR Phase I Project proposes a new passive microwave airborne sensor for in flight icing hazard detection, Microwave Radiometer for Aviation Safety. A feasibility...

  2. Microwave Radiometry and Radiometers for Ocean Applications

    DEFF Research Database (Denmark)

    Skou, Niels

    2008-01-01

    aperture radiometer technique, both yielding imaging capability without scanning. Typical applications of microwave radiometry concerning oceans are: sea salinity, sea surface temperature, wind speed and direction, sea ice detection and classification. However, in an attempt to measure properties...

  3. Digital Array Gas Radiometer (DAGR) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The digital array gas radiometer (DAGR) is a new sensor design for accurate measurement and monitoring of trace gases in the boundary layer from space, aircraft, or...

  4. Rapid mass spectrometric analysis of 15N-Leu incorporation fidelity during preparation of specifically labeled NMR samples

    DEFF Research Database (Denmark)

    Truhlar, Stephanie M E; Cervantes, Carla F; Torpey, Justin W

    2008-01-01

    Advances in NMR spectroscopy have enabled the study of larger proteins that typically have significant overlap in their spectra. Specific (15)N-amino acid incorporation is a powerful tool for reducing spectral overlap and attaining reliable sequential assignments. However, scrambling of the label...... during protein expression is a common problem. We describe a rapid method to evaluate the fidelity of specific (15)N-amino acid incorporation. The selectively labeled protein is proteolyzed, and the resulting peptides are analyzed using MALDI mass spectrometry. The (15)N incorporation is determined...... by analyzing the isotopic abundance of the peptides in the mass spectra using the program DEX. This analysis determined that expression with a 10-fold excess of unlabeled amino acids relative to the (15)N-amino acid prevents the scrambling of the (15)N label that is observed when equimolar amounts are used...

  5. Preparation of {sup 14}C-Labeled Multi-walled Carbon Nano-tubes for Biodistribution Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Georgin, D.; Czarny, B.; Botquin, M.; Mayne-L' Hermite, M.; Pinault, M.; Bouchet-Fabre, B.; Carriere, M.; Poncy, J.L.; Chau, Q.; Maximilien, R.; Dive, V.; Taran, F. [CEA, IBITECS, SCBM, 91191 Gif sur Yvette (France); CEA, IBITECS, SIMOPRO, 91191 Gif sur Yvette (FR); CEA, IRAMIS, SPAM, 91191 Gif sur Yvette (FR); CEA, IRAMIS, SCM, 91191 Gif sur Yvette (FR); CEA, IRCM, SREIT, 91680 Bruyeres le Chatel (FR)

    2009-07-01

    A new method allowing the {sup 14}C-labeling of carboxylic acid functions of carbon nano-tubes is described. The key step of the labeling process is a de-carbonylation reaction that has been developed and optimized with the help of a screening method. The optimized process has been successfully applied to multi-walled carbon nano-tubes (MWNTs), and the corresponding {sup 14}C-labeled nano-tubes were used to investigate their in vivo behavior. Preliminary results obtained after i.v. contamination of rats revealed liver as the main target organ. Radiolabeling of NTs with a long-life radioactive nucleus like {sup 14}C, coupled to a highly sensitive autoradiographic method, that provides a unique detection threshold, will make it possible to determine for a long time period whether or not NTs remain in any organs after animal exposure. (authors)

  6. Preparation of iodine-123 labeled AM251: a potential SPECT radioligand for the brain cannabinoid CB1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Ruoxi; Makriyannis, Alexandros [Connecticut Univ., Molecular and Cell Biology Dept., Storrs, CT (United States); Gatley, S.J. [Brookhaven National Lab., Medical Dept., Upton, NY (United States)

    1996-10-01

    We report the synthesis and labeling with iodine-123 of N-(piperidin-1-yl)-5-(4-iodophenyl)-1-(2, 4-dichlorophenyl)-4-methyl-1H-pyrazole-3-carboxamide (AM251). This compound is an analog of the recently described cannabinoid receptor antagonist, SR141716A, in which a 4-chlorophenyl group is replaced by 4-iodophenyl. Labeling in good yield (62%) and radiochemical purity (> 95%), and high specific activity (> 2500 Ci/mmol) was achieved by an iododestannylation reaction using the tributyltin precursor, no carrier added I-123 iodide, and chloramine-T. (author).

  7. Preparation of Uniformly 13C,15N-Labeled Recombinant Human Amylin for Solid-State NMR Investigation

    DEFF Research Database (Denmark)

    Kosicka, Iga; Kristensen, Torsten; Bjerring, Morten

    2014-01-01

    of amyloidogenic proteins in large amounts remains challenging due to their aggregation potential, toxicity for cells and difficult purification. In this work, we report a method for the production of large amounts of uniformly labeled 13C,15N-human amylin, being one of the most amyloidogenic peptides known...... crystal ordering, solid-state NMR forms the most suited method to determine the structures of the fibrils with atomic resolution. To exploit this potential, large amounts of isotopic-labeled protein need to be obtained through recombinant protein expression. However, expression and purification...

  8. Preparation of LW type multifunctional label adhesive%LW型多功能标签胶粘剂的研制

    Institute of Scientific and Technical Information of China (English)

    杨久义; 李俊新; 张士莹

    2001-01-01

    介绍一种既适用于啤酒瓶封口标签粘接,又适用于商标标签粘接的多功能胶粘剂生产工艺。该产品以干酪素和玉米淀粉为主成分配以分散剂、螯合剂制备而成,其初粘度大,稳定性好,可替代进口产品,经在300 kt*a-1啤酒包装生产线上应用半年,效果良好。%A new kind of multifunctional label adhesive, which is suitable for adhering metal label as well as paper label to beer bottle,and its produce method are presented.This kind of adhesive has a good primary adhesion and stability,and been successtully used in the produce lines of labeling for beer bottle of 300kt*a-1 for half a year,which shows it can substitute for the import products thoroughly.

  9. 21 CFR 250.12 - Stramonium preparations labeled with directions for use in self-medication regarded as misbranded.

    Science.gov (United States)

    2010-04-01

    ... for use in self-medication regarded as misbranded. 250.12 Section 250.12 Food and Drugs FOOD AND DRUG... for use in self-medication regarded as misbranded. (a) Stramonium products for inhalation have been... ingredients, will be regarded as misbranded if they are labeled with directions for use in self-medication....

  10. Preparation, quality control and biological evaluation of {sup 99m}Tc-labelled cationic steroid antibiotic (CSA-13)

    Energy Technology Data Exchange (ETDEWEB)

    Roohi, S.; Amir, N.; Mushtaq, A.; Salahuddin, S.M.; Jehangir, M. [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Isotope Production Div.; Savage, P.B. [Brigham Young Univ., Provo, UT (United States). Dept. of Chemistry and Biochemistry

    2009-07-01

    Ceragenins (CSAs) are a new class of antimicrobial agents that display broad spectrum antibacterial activity and may find use in the treatment of various infections. A member of this class CSA-13 was labelled with {sup 99m}Tc using SnCl{sub 2}.H{sub 2}O as a reducing agent. The labelling efficiency depended on the ligand/reductant ratio, pH and volume of the reaction mixture. The radiochemical purity and stability of {sup 99m}Tc-CSA was determined by thin layer chromatography. Biodistribution studies of {sup 99m}Tc-CSA were performed in Sprague Dawley rats. Liver and spleen uptake was quite high. A significantly higher accumulation of {sup 99m}Tc-CSA was seen at sites of S. aureus infected rats. The results were compared with {sup 99m}Tc-Ciprofloxacin. (orig.)

  11. View-limiting shrouds for insolation radiometers

    Science.gov (United States)

    Dennison, E. W.; Trentelman, G. F.

    1985-01-01

    Insolation radiometers (normal incidence pyrheliometers) are used to measure the solar radiation incident on solar concentrators for calibrating thermal power generation measurements. The measured insolation value is dependent on the atmospheric transparency, solar elevation angle, circumsolar radiation, and radiometer field of view. The radiant energy entering the thermal receiver is dependent on the same factors. The insolation value and the receiver input will be proportional if the concentrator and the radiometer have similar fields of view. This report describes one practical method for matching the field of view of a radiometer to that of a solar concentrator. The concentrator field of view can be calculated by optical ray tracing methods and the field of view of a radiometer with a simple shroud can be calculated by using geometric equations. The parameters for the shroud can be adjusted to provide an acceptable match between the respective fields of view. Concentrator fields of view have been calculated for a family of paraboloidal concentrators and receiver apertures. The corresponding shroud parameters have also been determined.

  12. The preparation of glucose uniformly labelled with carbon-14; Preparacion de glucosa uniformemente marcada con carbono-14

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M. D.; Suarez, C.; Rodrigo, M. E.

    1978-07-01

    The plant, (Zea mais, L) and culture conditions for an optimum production of glucose has been chosen. To achieve the labelling of glucose, photosynthesis and carboxylation are carried on, under an artificial atmosphere of 14CO{sub 2} produced from 14{sup C}-barium carbonate. Following photosynthesis the sugars are extracted, and then the extract purified by several methods. The purified glucose is finally, degraded and the specific radioactivity is determined in each of its carbon atoms. (Author) 37 refs.

  13. Preparation and preliminary studies on {sup 177}Lu-labeled hydroxyapatite particles for possible use in the therapy of liver cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Das, Tapas [Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Sarma, Haladhar D. [Radiation Biology and Health Sciences Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Venkatesh, Meera [Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Banerjee, Sharmila [Radiopharmaceuticals Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)], E-mail: sharmila@barc.gov.in

    2008-07-15

    Introduction: Intra-arterial administration of particulates labeled with suitable {beta}{sup -}-emitting radionuclides has emerged as one of the most successful modality for the treatment of primary and metastatic liver cancer. {sup 177}Lu [T{sub 1/2}=6.73 d, E{sub {beta}}(max)=0.49 MeV, E{sub {gamma}}=208 keV (11%)] could be envisaged as a viable radionuclide for use in liver cancer therapy with wider acceptability owing to its feasibility of production in large-scale and relatively longer half-life providing logistic advantages. Hydroxyapatite (HA) particles of 20-60 {mu}m size range are chosen as the particulate carrier due to its excellent biocompatibility and ease of labeling with lanthanides. Methods: {sup 177}Lu was produced by thermal neutron bombardment on enriched Lu target. HA particles of desired size range were synthesized and characterized. Radiolabeling of HA particles was achieved at room temperatures within 30 min. The biological behavior of {sup 177}Lu-labeled HA particles prepared under optimized conditions was tested in Wistar rats. Results: {sup 177}Lu was produced with a specific activity of 444.2{+-}41.8 GBq/mg and radionuclidic purity of 99.98%. {sup 177}Lu-HA was prepared with high radiochemical purity of >99%, and the radiolabeled agent showed excellent in vitro stability. The agent exhibited {approx}73% retention of injected activity in liver after 14 days postadministration with insignificant uptake in any other major organ/tissue except skeleton in biodistribution and imaging studies. Conclusion: {sup 177}Lu-HA exhibited promising features in radiochemical studies. However, preliminary biodistribution studies in normal Wistar rats exhibited suboptimum liver retention and an undesirable skeletal uptake.

  14. The Hurricane Imaging Radiometer: Present and Future

    Science.gov (United States)

    Miller, Timothy L.; James, M. W.; Roberts, J. B.; Biswas, S. K.; Cecil, D.; Jones, W. L.; Johnson, J.; Farrar, S.; Sahawneh, S.; Ruf, C. S.; Morris, M.; Uhlhorn, E. W.; Black, P. G.

    2013-01-01

    The Hurricane Imaging Radiometer (HIRAD) is an airborne passive microwave radiometer designed to provide high resolution, wide swath imagery of surface wind speed in tropical cyclones from a low profile planar antenna with no mechanical scanning. Wind speed and rain rate images from HIRAD's first field campaign (GRIP, 2010) are presented here followed, by a discussion on the performance of the newly installed thermal control system during the 2012 HS3 campaign. The paper ends with a discussion on the next generation dual polarization HIRAD antenna (already designed) for a future system capable of measuring wind direction as well as wind speed.

  15. Dual Microwave Radiometer Experiment Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Marchand, Roger [Univ. of Washington, Seattle, WA (United States)

    2017-09-01

    Passive microwave radiometers (MWRs) are the most commonly used and accurate instruments the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Research Facility has to retrieve cloud liquid water path (LWP). The MWR measurements (microwave radiances or brightness temperatures) are often used to derive LWP using climatological constraints, but are frequently also combined with measurements from radar and other instruments for cloud microphysical retrievals. Nominally this latter approach improves the retrieval of LWP and other cloud microphysical quantities (such as effective radius or number concentration), but this also means that when MWR data are poor, other cloud microphysical quantities are also negatively affected. Unfortunately, current MWR data is often contaminated by water on the MWR radome. This water makes a substantial contribution to the measured radiance and typically results in retrievals of cloud liquid water and column water vapor that are biased high. While it is obvious when the contamination by standing water is large (and retrieval biases are large), much of the time it is difficult to know with confidence that there is no contamination. At present there is no attempt to estimate or correct for this source of error, and identification of problems is largely left to users. Typically users are advised to simply throw out all data when the MWR “wet-window” resistance-based sensor indicates water is present, but this sensor is adjusted by hand and is known to be temperamental. In order to address this problem, a pair of ARM microwave radiometers was deployed to the University of Washington (UW) in Seattle, Washington, USA. The radiometers were operated such that one radiometer was scanned under a cover that (nominally) prevents this radiometer radome from gathering water and permits measurements away from zenith; while the other radiometer is operated normally – open or uncovered - with the radome exposed to the sky

  16. Preparation and in vivo evaluation of multifunctional ⁹⁰Y-labeled magnetic nanoparticles designed for cancer therapy.

    Science.gov (United States)

    Radović, Magdalena; Calatayud, María Pilar; Goya, Gerardo Fabián; Ibarra, Manuel Ricardo; Antić, Bratislav; Spasojević, Vojislav; Nikolić, Nadežda; Janković, Drina; Mirković, Marija; Vranješ-Đurić, Sanja

    2015-01-01

    Two different types of magnetic nanoparticles (MNPs) were synthesized in order to compare their efficiency as radioactive vectors, Fe₃O₄-Naked (80 ± 5 nm) and polyethylene glycol 600 diacid functionalized Fe₃O₄(Fe₃O₄-PEG600) MNPs (46 ± 0.6 nm). They were characterized based on the external morphology, size distribution, and colloidal and magnetic properties. The obtained specific power absorption value for Fe₃O₄-PEG600 MNPs was 200 W/g, indicated their potential in hyperthermia based cancer treatments. The labeling yield, in vitro stability and in vivo biodistribution profile of (90) Y-MNPs were compared. Both types of MNPs were (90)Y-labeled in reproducible high yield (>97%). The stability of the obtained radioactive nanoparticles was evaluated in saline and human serum media in order to optimize the formulations for in vivo use. The biodistribution in Wistar rats showed different pharmacokinetic behaviors of nanoparticles: a large fraction of both injected MNPs ended in the liver (14.58%ID/g for (90)Y-Fe₃O₄-Naked MNPs and 19.61%ID/g for (90)Y-Fe₃O₄-PEG600 MNPs) whereas minor fractions attained in other organs. The main difference between the two types of MNPs was the higher accumulation of (90)Y-Fe₃O₄-Naked MNPs in the lungs (12.14%ID/g vs. 2.00%ID/g for (90)Y-Fe₃O₄-PEG600 MNPs) due to their in vivo agglomeration. The studied radiolabeled magnetic complexes such as (90)Y-Fe₃O₄-PEG600 MNPs constitute a great promise for multiple diagnostic-therapeutic uses combining, for example, MRI-magnetic hyperthermia and regional radiotherapy.

  17. Application of Uncooled Monolithic Thermoelectric Linear Arrays to Imaging Radiometers

    Science.gov (United States)

    Kruse, Paul W.

    Introduction Identification of Incipient Failure of Railcar Wheels Technical Description of the Model IR 1000 Imaging Radiometer Performance of the Model IR 1000 Imaging Radiometer Initial Application Summary Imaging Radiometer for Predictive and Preventive Maintenance Description Operation Specifications Summary References INDEX CONTENTS OF VOLUMES IN THIS SERIES

  18. Preparation and preliminary biological evaluation of radiogallium-labeled DTPA-amlodipine complex for possible L-type calcium channel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Firuzyar, Tahereh; Shafiee-Ardestani, Mehdi; Khalaj, Ali [Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of). Faculty of Pharmacy; Jalilian, Amir R.; Fazaeli, Yousef; Aboudzadeh, Mohammad Reza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of). Radiopharmacy Research Group

    2014-07-01

    A DTPA-conjugated amlodipine analog (DTPA-AMLO) 3, was prepared for possible voltage gated calcium channel imaging after radiolabeling with Ga-67. [{sup 67}Ga]-DTPA-AMLO complex was prepared starting [{sup 67}Ga]gallium chloride and DTPA-AMLO in 60-90 min at 50-60 C in phosphate buffer. The partition co-efficient and stability of the tracer was determined in final solution (25 C) and presence of human serum (37 C) up to 24 h. The biodistribution of the labeled compound in wild-type rats were determined up to 72 h using organ counting and SPECT. The radiolabled complex was prepared in high radiochemical purity (>96%, RTLC and >98% HPLC) and significant specific activity (7-10 GBq/mmol). The log P for the complex was calculated as -0.594, consistent with a water soluble complex. The tracer is mostly washed out through kidneys which were in full compliance with the amlodipine metabolism and imaging studies demonstrated the same behavior. The tracer uptake in organs with smooth muscles was observed in stomach, colon as well as intestine.

  19. Modeling the frequency response of microwave radiometers with QUCS

    Science.gov (United States)

    Zonca, A.; Roucaries, B.; Williams, B.; Rubin, I.; D'Arcangelo, O.; Meinhold, P.; Lubin, P.; Franceschet, C.; Jahn, S.; Mennella, A.; Bersanelli, M.

    2010-12-01

    Characterization of the frequency response of coherent radiometric receivers is a key element in estimating the flux of astrophysical emissions, since the measured signal depends on the convolution of the source spectral emission with the instrument band shape. Laboratory Radio Frequency (RF) measurements of the instrument bandpass often require complex test setups and are subject to a number of systematic effects driven by thermal issues and impedance matching, particularly if cryogenic operation is involved. In this paper we present an approach to modeling radiometers bandpasses by integrating simulations and RF measurements of individual components. This method is based on QUCS (Quasi Universal Circuit Simulator), an open-source circuit simulator, which gives the flexibility of choosing among the available devices, implementing new analytical software models or using measured S-parameters. Therefore an independent estimate of the instrument bandpass is achieved using standard individual component measurements and validated analytical simulations. In order to automate the process of preparing input data, running simulations and exporting results we developed the Python package python-qucs and released it under GNU Public License. We discuss, as working cases, bandpass response modeling of the COFE and Planck Low Frequency Instrument (LFI) radiometers and compare results obtained with QUCS and with a commercial circuit simulator software. The main purpose of bandpass modeling in COFE is to optimize component matching, while in LFI they represent the best estimation of frequency response, since end-to-end measurements were strongly affected by systematic effects.

  20. Modeling the frequency response of microwave radiometers with QUCS

    Energy Technology Data Exchange (ETDEWEB)

    Zonca, A; Williams, B; Rubin, I; Meinhold, P; Lubin, P [Department of Physics, University of California, Santa Barbara, Santa Barbara, CA 93106 (United States); Roucaries, B [Universite Paris-Est, Laboratoire Central des Ponts et Chaussees, 75732 Paris (France); D' Arcangelo, O [IFP-CNR, via Cozzi 53, 20125 Milano (Italy); Franceschet, C; Mennella, A; Bersanelli, M [Dipartimento di Fisica, Universita degli Studi di Milano, Via Celoria 16, 20133 Milano (Italy); Jahn, S, E-mail: zonca@deepspace.ucsb.edu [Infineon Technologies AG, Am Campeon 1-12, 85579 Neubiberg, Munich (Germany)

    2010-12-15

    Characterization of the frequency response of coherent radiometric receivers is a key element in estimating the flux of astrophysical emissions, since the measured signal depends on the convolution of the source spectral emission with the instrument band shape. Laboratory Radio Frequency (RF) measurements of the instrument bandpass often require complex test setups and are subject to a number of systematic effects driven by thermal issues and impedance matching, particularly if cryogenic operation is involved. In this paper we present an approach to modeling radiometers bandpasses by integrating simulations and RF measurements of individual components. This method is based on QUCS (Quasi Universal Circuit Simulator), an open-source circuit simulator, which gives the flexibility of choosing among the available devices, implementing new analytical software models or using measured S-parameters. Therefore an independent estimate of the instrument bandpass is achieved using standard individual component measurements and validated analytical simulations. In order to automate the process of preparing input data, running simulations and exporting results we developed the Python package python-qucs and released it under GNU Public License. We discuss, as working cases, bandpass response modeling of the COFE and Planck Low Frequency Instrument (LFI) radiometers and compare results obtained with QUCS and with a commercial circuit simulator software. The main purpose of bandpass modeling in COFE is to optimize component matching, while in LFI they represent the best estimation of frequency response, since end-to-end measurements were strongly affected by systematic effects.

  1. Preparation

    Directory of Open Access Journals (Sweden)

    M.M. Dardir

    2014-03-01

    Full Text Available Some hexanamide-mono and di-linoleniate esters were prepared by the reaction of linolenic acid and hexanamide (derived from the reaction of hexanoic acid and diethanolamine. The chemical structure for the newly prepared hexanamide-mono and di-linoleniate esters were elucidated using elemental analysis, (FTIR, H 1NMR and chemical ionization mass spectra (CI/Ms spectroscopic techniques. The results of the spectroscopic analysis indicated that they were prepared through the right method and they have high purity. The new prepared esters have high biodegradability and lower toxicity (environmentally friendly so they were evaluated as a synthetic-based mud (ester-based mud for oil-well drilling fluids. The evaluation included study of the rheological properties, filtration and thermal properties of the ester based-muds formulated with the newly prepared esters compared to the reference commercial synthetic-based mud.

  2. Radiometer calibration methods and resulting irradiance differences: Radiometer calibration methods and resulting irradiance differences

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron [National Renewable Energy Laboratory, Golden CO 80401 USA; Sengupta, Manajit [National Renewable Energy Laboratory, Golden CO 80401 USA; Andreas, Afshin [National Renewable Energy Laboratory, Golden CO 80401 USA; Reda, Ibrahim [National Renewable Energy Laboratory, Golden CO 80401 USA; Robinson, Justin [GroundWork Renewables Inc., Logan UT 84321 USA

    2016-10-07

    Accurate solar radiation measured by radiometers depends on instrument performance specifications, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methodologies and resulting differences provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these methods calibrate radiometers indoors and some outdoors. To establish or understand the differences in calibration methodologies, we processed and analyzed field-measured data from radiometers deployed for 10 months at NREL's Solar Radiation Research Laboratory. These different methods of calibration resulted in a difference of +/-1% to +/-2% in solar irradiance measurements. Analyzing these differences will ultimately assist in determining the uncertainties of the field radiometer data and will help develop a consensus on a standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainties will help the accurate prediction of the output of planned solar conversion projects and improve the bankability of financing solar projects.

  3. Preparation of 18F-labeled peptides using the copper(I)-catalyzed azide-alkyne 1,3-dipolar cycloaddition.

    Science.gov (United States)

    Gill, Herman S; Marik, Jan

    2011-10-13

    An optimized procedure for preparing fluorine-18 ((18)F)-labeled peptides by the copper-catalyzed azide-alkyne 1,3-dipolar cyloaddition (CuAAC) is presented here. The two-step radiosynthesis begins with the microwave-assisted nucleophilic (18)F-fluorination of a precursor containing a terminal p-toluenesulfonyl, terminal azide and polyethylene glycol backbone. The resulting (18)F-fluorinated azide-containing building block is coupled to an alkyne-decorated peptide by the CuAAC. The reaction is accelerated by the copper(I)-stabilizing ligand bathophenanthroline disulfonate and can be performed in either reducing or nonreducing conditions (e.g., to preserve disulfide bonds). After an HPLC purification, (18)F-labeled peptide can be obtained with a 31 ± 6% radiochemical yield (n = 4, decay-corrected from (18)F-fluoride elution) and a specific activity of 39.0 ± 12.4 Ci μmol(-1) within 77 ± 4 min.

  4. A semi-preparative enzymic synthesis of malonyl-CoA from [14C]acetate and 14CO2: labelling in the 1, 2 or 3 position.

    Science.gov (United States)

    Roughan, G

    1994-06-01

    A semi-preparative enzymic synthesis of [1-14C]malonyl-CoA from [1-14C]acetate and bicarbonate, and of [3-14C]malonyl-CoA from Na2(14)CO3 and acetate, was achieved by using chloroplasts rapidly isolated from 7-8-day-old pea shoots. Around 70% of the [1-14C]acetate was converted into malonyl-CoA in 2-3 h, and the specific radioactivity of [3-14C]malonyl-CoA synthesized in the system was 25-30 Ci/mol. Reactions were monitored and labelled products were purified by h.p.l.c.

  5. Preparation of Alexa Fluor 350-conjugated nonradioactive or 3H-labeled GM1 ganglioside derivatives with different ceramides.

    Science.gov (United States)

    Panasiewicz, Mirosława; Domek, Hanna; Fedoryszak, Natalia; Pacuszka, Tadeusz

    2009-02-01

    Alexa Fluor 350 hydrazide (AF) was coupled to the aldehyde group at C-6 of terminal galactose of oxidized GM1 gangliosides containing different fatty acid residues (GM1s). The AF-GM1 hydrazones obtained were reduced with NaBH(4) or [3H]NaBH(4) and purified by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). Final yields of AF-GM1s exceeded 30%, purity was better than 97%, and radiochemical purity of 3H-labeled AF-GM1s was more than 94.5%. Structures of AF-GM1s were confirmed by electrospray ionization-mass spectrometry (ESI-MS). When added to HL-60 cell culture media, more than 81.6 or 78.9% of the AF-[3H]GM1s were taken up by cells in a bovine serum albumin- or trypsin-resistant manner, respectively. Approximately 70% of the AF-[3H]GM1s were recovered in HL-60 total plasma membrane fraction.

  6. LAT-1 based primary breast cancer detection by [99m]Tc-labeled DTPA-bis-methionine scintimammography: first results using indigenously developed single vial kit preparation.

    Science.gov (United States)

    Sharma, Sarika; Singh, Baljinder; Mishra, Anil K; Rathod, Deepti; Hazari, Puja Panwar; Chuttani, Krishna; Chopra, Shalini; Singh, Paramvir Mangat; Abrar, M L; Mittal, Bhagwant R; Singh, Gurpreet

    2014-09-01

    To evaluate the diagnostic utility of a single vial ready to label with [99m]Tc kit preparation of DTPA-bis-methionine (DTPA-bis-MET) for the detection of primary breast cancer. The conjugate (DTPA-bis-MET) was synthesized by covalently conjugating two molecules of methionine to DTPA and formulated as a single vial ready to label with [99m]Tc lyophilized kit preparations. Thirty female patients (mean age=47.5±11.8 years; range=21-69 years) with radiological/clinical evidence of having primary breast carcinoma were subjected to [99m]Tc-methionine scintigraphy. The whole body (anterior and posterior) imaging was performed on all the patients at 5 minutes, 10 minutes, 1 hour, 2 hours, and 4 hours following an intravenous administration of 555-740 MBq radioactivity of [99m]Tc-methionine. In addition, scintimammography (static images; 256×256 matrix) at 1, 2, and 4 hours was also performed on all the patients. The resultant radiolabel, that is, [99m]Tc-DTPA-bis-MET, yielded high radiolabeling efficiency (>97.0%), radiochemical purity (166-296 MBq/μmol), and shelf life (>3 months). The radiotracer primarily gets excreted through the kidneys and localizes in the breast cancer lesions with high target-to-nontarget ratios. The mean±SD ratios on the scan-positive lesions acquired at 1, 2, and 4 hours postinjection were 3.6±0.48, 3.10±0.24, and 2.5±0.4, respectively. [99m]Tc-methionine scintimammography demonstrated an excellent sensitivity and positive predictive value of 96.0% each for the detection of primary breast cancer. Ready to label single vial kit formulations of DTPA-bis-MET can be easily synthesized as in-house production and conveniently used for the scintigraphic detection of breast cancer and other methionine-dependent tumors expressing the L-type amino acid transporter-1 receptor. The imaging technique thus could be a potential substitute for the conventional single-photon emission computed tomography (SPECT)-based tumor imaging agents, especially

  7. Preparation of lyophilized kit of HYNIC-[Tyr3]-Octreotate and labelling studies with 99m-Technetium; Preparo do reagente liofilizado HYNIC-[Ty3{sup 3}]-Octreotato e estudo de marcacao com Tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Ivani Bortoleti

    2008-07-01

    The development of radiolabeled molecules with high specificity for an organ ar tumor has been contributed to the precise diagnostic in nuclear medicine. Somatostatin labeled derivatives constitutes a particular example of labeled peptide applied in the localization of neuroendocrine tumors. Nowadays, the {sup 111}In DTPA-octreotide is the radiopharmaceutical applied in diagnostic procedures for the visualization of tumors with high expression of somatostatin receptors. However, the 111-indium is a radionuclide that presents some limitations related to availability (cyclotron production), half-life (67 hours) and the emission of medium energy photons (171 keV e 245 keV), not favorable to the acquisition of images in SPECT (Single Photon Emission Computed Tomography). The favorable physical properties of the {sup 99m}-technetium ({sup 99m}Tc) make this radionuclide the more favorable to substitute the 111-indium on peptide labeling procedures. This work studied the preparation and labeling of a lyophilized kit of HYNIC-Tyr{sup 3}-octreotate (HYNIC-octreotate) with {sup 99m}Tc, base on previously described procedures and using tricine and EDDA (ethylendiaminediacetic acid) as coligands. It was studied the labeling parameters (incubation time, temperature, volume and perthecnetate activity) and the stability of the lyophilized preparation. Additionally, it was studied the influence of the pre-freezing using liquid nitrogen in the stability of the lyophilized preparation, as well as the influence of manitol in the labeling yield and biological distribution of the complex. The stability studies showed that the lyophilization using liquid nitrogen pre-freezing resulted in a lyophilized preparation with stability over 4 month when stored under refrigeration. The stability of the lyophilized preparation obtained without liquid nitrogen pre-freezing was similar.The labeling studies determined the best labeling conditions, resulting in a radiochemical yield superior than 90

  8. Preparation and biodistribution of 188Re-labeled folate conjugated human serum albumin magnetic cisplatin nanoparticles (188Re-folate-CDDP/HSA MNPs in vivo

    Directory of Open Access Journals (Sweden)

    Tang QS

    2011-11-01

    were injected into nude mice. Uptake of 188Re-folate-CDDP/HSA magnetic nanoparticles increased gradually after injection, peaked at 8 hours with a value of 8.83 ± 1.71, and slowly decreased over 24 hours in vivo.Conclusion: These results indicate that 188Re-folate-CDDP/HSA magnetic nanoparticles can be used in radionuclide-targeted cancer therapy. Surface-modified albumin nanoparticles with folic acid ligand-labeled radionuclide (188Re were successfully prepared, laying the foundation for a triple-killing effect of thermotherapy, chemotherapy, and radiation therapy.Keywords: cisplatin, folic acid, albumin, magnetic nanoparticles, 188Re, ovarian cancer

  9. Carbon dots prepared by hydrothermal treatment of dopamine as an effective fluorescent sensing platform for the label-free detection of iron(III) ions and dopamine.

    Science.gov (United States)

    Qu, Konggang; Wang, Jiasi; Ren, Jinsong; Qu, Xiaogang

    2013-05-27

    A facile, economic and green one-step hydrothermal synthesis route using dopamine as source towards photoluminescent carbon nanoparticles (CNPs) is proposed. The as-prepared CNPs have an average size about 3.8 nm. The emission spectra of the CNPs are broad, ranging from approximately 380 (purple) to approximately 525 nm (green), depending on the excitation wavelengths. Due to the favorable optical properties, the CNPs can readily enter into A549 cells and has been used for multicolor biolabeling and bioimaging. Most importantly, the as-prepared CNPs contain distinctive catechol groups on their surfaces. Due to the special response of catechol groups to Fe(3+) ions, we further demonstrate that such wholly new CNPs can serve as a very effective fluorescent sensing platform for label-free sensitive and selective detection of Fe(3+) ions and dopamine with a detection limit as low as 0.32 μM and 68 nM, respectively. The new "mix-and-detect" strategy is simple, green, and exhibits high sensitivity and selectivity. The present method was also applied to the determination of Fe(3+) ions in real water samples and dopamine in human urine and serum samples successfully. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Ozone monitoring with an infrared heterodyne radiometer

    Science.gov (United States)

    Menzies, R. T.; Seals, R. K., Jr.

    1977-01-01

    Measurements of the total burden and of the concentration-versus-altitude profiles of ozone have been made with a ground-based heterodyne radiometer at Pasadena, California. The measurements were made in the 9.5-micron wavelength region, where a strong ozone infrared absorption band exists. The radiometer measured solar absorption at selected wavelengths with a spectral resolution of 0.001 reciprocal centimeter, equivalent to the half-width of an ozone absorption line at the 10-millibar altitude level. A carbon dioxide laser served as the local oscillator. This technique can be used to gather important data on both tropospheric and stratospheric ozone, which are not readily accessible with other remote-sensing techniques.

  11. Improved synthesis of anti-[{sup 18}F]FACBC: improved preparation of labeling precursor and automated radiosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    McConathy, Jonathan; Voll, Ronald J.; Yu Weiping; Crowe, Ronald J.; Goodman, Mark M. E-mail: mgoodma@emory.edu

    2003-06-01

    The non-natural amino acid anti-1-amino-3-[{sup 18}F]fluorocyclobutyl-1-carboxylic acid (FACBC) has shown promise for tumor imaging with positron emission tomography. An improved synthesis of the precursor of anti-[{sup 18}F]FACBC has been devised which demonstrates high stereoselectivity and suitability for large-scale preparations. An automated radiosynthesis has been developed which provides anti-[{sup 18}F]FACBC in 24% decay-corrected yield. Additionally, the major non-radioactive species present in doses of anti-[{sup 18}F]FACBC has been identified as anti-1-amino-3-hydroxycyclobutane-1-carboxylic acid. Together, these results are important steps towards the routine production of anti-[{sup 18}F]FACBC for human use.

  12. Analysis of radiometer calibration effects with TOUCHSTONE

    Science.gov (United States)

    Stanley, William D.

    1990-01-01

    The microwave circuit analysis program TOUCHSTONE is used to study two effects of importance in radiometer calibration. The two effects are impedance mismatches at the antenna-air and cold load-air interfaces and dissipatives losses, which radiate thermal noise into the system. The results predicted by TOUCHSTONE are shown to be in very close agreement with earlier results obtained by purely analytical methods. The techniques used in establishing the circuit models and in processing the resulting data are described in detail.

  13. Advanced Microwave Radiometer (AMR) for SWOT mission

    Science.gov (United States)

    Chae, C. S.

    2015-12-01

    The objective of the SWOT (Surface Water & Ocean Topography) satellite mission is to measure wide-swath, high resolution ocean topography and terrestrial surface waters. Since main payload radar will use interferometric SAR technology, conventional microwave radiometer system which has single nadir look antenna beam (i.e., OSTM/Jason-2 AMR) is not ideally applicable for the mission for wet tropospheric delay correction. Therefore, SWOT AMR incorporates two antenna beams along cross track direction. In addition to the cross track design of the AMR radiometer, wet tropospheric error requirement is expressed in space frequency domain (in the sense of cy/km), in other words, power spectral density (PSD). Thus, instrument error allocation and design are being done in PSD which are not conventional approaches for microwave radiometer requirement allocation and design. A few of novel analyses include: 1. The effects of antenna beam size to PSD error and land/ocean contamination, 2. Receiver error allocation and the contributions of radiometric count averaging, NEDT, Gain variation, etc. 3. Effect of thermal design in the frequency domain. In the presentation, detailed AMR design and analyses results will be discussed.

  14. Food Labels

    Science.gov (United States)

    ... Surgery? Choosing the Right Sport for You Shyness Food Labels KidsHealth > For Teens > Food Labels Print A ... have at least 95% organic ingredients. continue Making Food Labels Work for You The first step in ...

  15. Preparation of 14-C-labelled 1,4-Dideoxy-1,4-imino-D-arabinitol: Cyanosilylation of Cyclic Imines using KCN in a One-Pot Synthesis

    DEFF Research Database (Denmark)

    Lundt, Inge; Malle, Birgitte Mølholm; Foged, Christian;

    1999-01-01

    A new method for C-C bond formation was developed based on in situ cyanosilylation of cyclic Schiff bases using KCN, TMSCl, KI and ZnI2. This method was used to prepare the potent -glucosidase inhibitor 1,4-dideoxy-1,4-imino-D-arabinitol 14-C labelled at C-5.Keywords: in situ cyanosilylation; 14-C...

  16. A new radiometer for earth radiation budget studies

    Energy Technology Data Exchange (ETDEWEB)

    Weber, P.G.

    1992-01-01

    A critical need for the US Global Change Research Program is to provide continuous, well-calibrated radiometric data for radiation balance studies. This paper describes a new, compact, relatively light-weight, adaptable radiometer which will provide both spectrally integrated measurements and data in selected spectral bands. The radiometer design is suitable for use on (small) satellites, aircraft, or Unmanned Aerospace Vehicles (UAVs). Some considerations for the implementation of this radiometer on a small satellite are given. 17 refs.

  17. Efficacy of a standardized herbal preparation (Roidosanal® in the treatment of hemorrhoids: A randomized, controlled, open-label multicentre study

    Directory of Open Access Journals (Sweden)

    Kapil Aggrawal

    2014-01-01

    Full Text Available Background: Catechins and epicatechins are monomers of naturally occurring proanthocyanidins, which have been reported with free radical scavenging, antioxidant, antiinflammatory, antiallergic, and vasodilatory properties. Plant parts rich in proanthocyanidins have been used for years in treatment of various ano-rectal diseases. This study compares the efficacy of two herbal preparations, Daflon® 500 mg and Roidosanal® , in ameliorating the signs and symptoms associated with hemorrhoids. Objective: To evaluate the safety and to compare the efficacy of a herbal preparation, Roidosanal® versus Daflon® 500 mg, on signs and symptoms of hemorrhoidal disease. Materials and Methods: In this pilot, active controlled, open-labeled multicentre study, 73 patients with proctoscopy proven hemorrhoids (Grade I to III were randomly assigned to receive either Roidosanal® (Gr R; n = 37 or Daflon® 500 mg (Gr D; n = 36, for 15 days, at three centers in India. Assessment of hemorrhoidal symptoms was carried out in all patients at different time points. Intent-to-treat analysis was performed for both primary and secondary endpoints. Results: Baseline characteristics were comparable between the two groups. Both products were found to be equally effective in improving the ano-rectal conditions in Grade I and Grade II hemorrhoids; however, Roidosanal® demonstrated better efficacy in patients with Grade III hemorrhoids. Hemorrhoids associated symptoms like bleeding, pain, etc., improved in both groups, although intergroup comparisons were comparable. Conclusion: Both Roidosanal® and Daflon® 500 mg were equally effective in resolving signs and symptoms of hemorrhoids. Roidosanal® can be tried as a safe and effective treatment option for treatment of hemorrhoids. Further randomized, double-blind and large multicentre studies are recommended.

  18. Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER)

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset represents multiple products archived at the Land Processes DAAC for ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) aboard the...

  19. Galileo Net Flux Radiometer Data Analysis

    Science.gov (United States)

    Sromovsky, Lawrence A.

    1999-01-01

    This report describes analysis of the Galileo Net Flux Radiometer (NFR), an instrument mounted on the Galileo probe, a spacecraft designed for entry into and direct measurements of Jupiter's atmosphere. The grant period for NAG2-1028 began on 1 April 1996, nearly four months after Jupiter atmospheric entry on 7 December 1995, and at which time the probe data were fully recovered and quick look analysis completed. This grant supported the detailed data analysis, resulting in a preliminary paper in Science in May 1996 and a final paper in the journal of Geophysical Research in .September 1998, with conference papers presented within this period.

  20. RF Reference Switch for Spaceflight Radiometer Calibration

    Science.gov (United States)

    Knuble, Joseph

    2013-01-01

    The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve

  1. Infrared Correlation Radiometer for GEO-CAPE

    Science.gov (United States)

    Neil, D. O.; Boldt, J.; Edwards, D. P.; Yee, J.

    2009-12-01

    We present our plans as part of NASA’s Instrument Incubator Program to characterize the performance of a 2.3 μm infrared correlation radiometer (IRCR) prototype subsystem for an instrument designed specifically to measure carbon monoxide (CO) from geostationary orbit. The Earth Science and Applications Decadal Survey mission GEO-CAPE specifies infrared correlation radiometry to measure CO in two spectral regions. CO measurements at 2.3 μm are uniformly sensitive throughout the troposphere, and 4.7 μm measurements are most sensitive to the free troposphere. In combination, the measurements yield information of this Criteria Pollutant near Earth's surface. The success of NASA’s Shuttle-based Measurement of Air Pollution from Satellites (MAPS) and Terra/MOPITT infrared gas correlation radiometers for CO measurements at 4.7 μm shifts the technology focus toward improving existing 2.3 μm CO measurement capability. GEO-CAPE uses this robust IRCR measurement technique at GEO, nearly 50 times farther away than the Terra/MOPITT orbit, to determine hourly changes in CO across a continental domain. We have structured the IRCR project around an analytical performance model to enable rapid evaluation of design specifics once the mission is defined. We present the architecture of the performance model, and the design of the simulator hardware and test plan which will populate the performance model.

  2. Conceptual radiometer design studies for Earth observations from low Earth orbit

    Science.gov (United States)

    Harrington, Richard F.

    1994-01-01

    A conceptual radiometer design study was performed to determine the optimum design approach for spaceborne radiometers in low Earth orbit. Radiometric system configurations which included total power radiometers, unbalanced Dicke radiometers, and balanced Dicke, or as known as noise injection, radiometers were studied. Radiometer receiver configurations which were analyzed included the direct detection radiometer receiver, the double sideband homodyne radiometer receiver, and the single sideband heterodyne radiometer receiver. Radiometer system performance was also studied. This included radiometric sensitivity analysis of the three different radiometer system configurations studied. Both external and internal calibration techniques were analyzed. An accuracy analysis with and without mismatch losses was performed. It was determined that the balanced Dicke radiometer system configuration with direct detection receivers and external calibrations was optimum where frequent calibration such as once per minute were not feasible.

  3. Novel multi-beam radiometers for accurate ocean surveillance

    DEFF Research Database (Denmark)

    Cappellin, C.; Pontoppidan, K.; Nielsen, P. H.

    2014-01-01

    Novel antenna architectures for real aperture multi-beam radiometers providing high resolution and high sensitivity for accurate sea surface temperature (SST) and ocean vector wind (OVW) measurements are investigated. On the basis of the radiometer requirements set for future SST/OVW missions...

  4. Measurement errors with low-cost citizen science radiometers

    OpenAIRE

    Bardají, Raúl; Piera, Jaume

    2016-01-01

    The KdUINO is a Do-It-Yourself buoy with low-cost radiometers that measure a parameter related to water transparency, the diffuse attenuation coefficient integrated into all the photosynthetically active radiation. In this contribution, we analyze the measurement errors of a novel low-cost multispectral radiometer that is used with the KdUINO. Peer Reviewed

  5. A novel L-band polarimetric radiometer featuring subharmonic sampling

    DEFF Research Database (Denmark)

    Rotbøll, J.; Søbjærg, Sten Schmidl; Skou, Niels

    2003-01-01

    A novel L-band radiometer trading analog components for digital circuits has been designed, built and operated. It is a fully polarimetric radiometer of the correlation type, and it is based on the subharmonic sampling principle in which the L-band signal is directly sampled by a fast A to D...

  6. The DC-8 Submillimeter-Wave Cloud Ice Radiometer

    Science.gov (United States)

    Walter, Steven J.; Batelaan, Paul; Siegel, Peter; Evans, K. Franklin; Evans, Aaron; Balachandra, Balu; Gannon, Jade; Guldalian, John; Raz, Guy; Shea, James

    2000-01-01

    An airborne radiometer is being developed to demonstrate the capability of radiometry at submillimeter-wavelengths to characterize cirrus clouds. At these wavelengths, cirrus clouds scatter upwelling radiation from water vapor in the lower troposphere. Radiometric measurements made at multiple widely spaced frequencies permit flux variations caused by changes in scattering due to crystal size to be distinguished from changes in cloud ice content. Measurements at dual polarizations can also be used to constrain the mean crystal shape. An airborne radiometer measuring the upwelling submillimeter-wave flux should then able to retrieve both bulk and microphysical cloud properties. The radiometer is being designed to make measurements at four frequencies (183 GHz, 325 GHz, 448 GHz, and 643 GHz) with dual-polarization capability at 643 GHz. The instrument is being developed for flight on NASA's DC-8 and will scan cross-track through an aircraft window. Measurements with this radiometer in combination with independent ground-based and airborne measurements will validate the submillimeter-wave radiometer retrieval techniques. The goal of this effort is to develop a technique to enable spaceborne characterization of cirrus, which will meet a key climate measurement need. The development of an airborne radiometer to validate cirrus retrieval techniques is a critical step toward development of spaced-based radiometers to investigate and monitor cirrus on a global scale. The radiometer development is a cooperative effort of the University of Colorado, Colorado State University, Swales Aerospace, and Jet Propulsion Laboratory and is funded by the NASA Instrument Incubator Program.

  7. Etched track radiometers in radon measurements: a review

    CERN Document Server

    Nikolaev, V A

    1999-01-01

    Passive radon radiometers, based on alpha particle etched track detectors, are very attractive for the assessment of radon exposure. The present review considers various devices used for measurement of the volume activity of radon isotopes and their daughters and determination of equilibrium coefficients. Such devices can be classified into 8 groups: (i) open or 'bare' detectors, (ii) open chambers, (iii) sup 2 sup 2 sup 2 Rn chambers with an inlet filter, (iv) advanced sup 2 sup 2 sup 2 Rn radiometers, (v) multipurpose radiometers, (vi) radiometers based on a combination of etched track detectors and an electrostatic field, (vii) radiometers based on etched track detectors and activated charcoal and (viii) devices for the measurement of radon isotopes and/or radon daughters by means of track parameter measurements. Some of them such as the open detector and the chamber with an inlet filter have a variety of modifications and are applied widely both in geophysical research and radon dosimetric surveys. At the...

  8. A new biological method for preparing certain sulphurated substances labelled with S{sup 35}; Methode nouvelle de preparation par voie biologique de quelques substances soufrees marquees au soufre-35

    Energy Technology Data Exchange (ETDEWEB)

    Chapeville, F.; Maier-Huser, H.; Fromageot, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Previous investigations have shown that the yolk-sac of embryonic bird's eggs can be used to produce the following reactions: (a) reduction of sulphate to sulphite; (b) fixation of the sulphite on the carbon chain produced by the desulf-hydration of l-cysteine, with formation of l-cysteic acid; (c) decarboxylation of the l-cysteine acid into taurine. The enzymatic system which causes reaction (b) has been purified. It also acts as a catalyst in the sulphur-exchange between the cysteine and the mineral sulphide. The authors have utilized these data in preparing sulphurated substances labelled with S{sup 35}: taurine S{sup 35}, l-cysteine S{sup 35} and l-cysteic acid S{sup 35}. For each of the three, they discuss the chemical reactions involved, the methods of preparation, the experimental conditions of extraction and purity-control, together with the yields and specific activities obtained. (authors) [French] Des travaux anterieurs ont montre l'aptitude du sac vitellin d'oeufs embryonn d'oiseaux a realiser les reactions suivantes: a) reduction du sulfate en sulfite, b) fixation du sulfite sur la chaine carbonee issue de la desulfhydration de la L-cysteine avec formation de l'acide L-cysteique. c) decarboxylation de l 'acide L-cysteique en taurine. Le systeme enzymatique responsable de la reaction b a ete purifie; il catalyse aussi l'echange du soufre de la cysteine avec celui du sulfure mineral. Les auteurs ont utilise ces donnees pour la preparation de substances soufrees marquees au {sup 35}S: taurine {sup 35}S, L-cysteine{sup 35} et acide L-cysteique {sup 35}S. Pour chacun de ces trois corps, ils decrivent les reactions chimiques mises en jeu, les modes operatoires de fabrication, les conditions experimentales d'extraction et de controle de la purete, ainsi que les resultats obtenus tant pour les rendements que pour les activites specifiques obtenues. (auteurs)

  9. Microwave integrated circuit radiometer front-ends for the Push Broom Microwave Radiometer

    Science.gov (United States)

    Harrington, R. F.; Hearn, C. P.

    1982-01-01

    Microwave integrated circuit front-ends for the L-band, S-band and C-band stepped frequency null-balanced noise-injection Dicke-switched radiometer to be installed in the NASA Langley airborne prototype Push Broom Microwave Radiometer (PBMR) are described. These front-ends were developed for the fixed frequency of 1.413 GHz and the variable frequencies of 1.8-2.8 GHz and 3.8-5.8 GHz. Measurements of the noise temperature of these units were made at 55.8 C, and the results of these tests are given. While the overall performance was reasonable, improvements need to be made in circuit losses and noise temperatures, which in the case of the C-band were from 1000 to 1850 K instead of the 500 K specified. Further development of the prototypes is underway to improve performance and extend the frequency range.

  10. Ozone height profiles using laser heterodyne radiometer

    Science.gov (United States)

    Jain, S. L.

    1994-01-01

    The monitoring of vertical profiles of ozone and related minor constituents in the atmosphere are of great significance to understanding the complex interaction between atmospheric dynamics, chemistry and radiation budget. An ultra high spectral resolution tunable CO2 laser heterodyne radiometer has been designed, developed and set up at the National Physical Laboratory, New Delhi to obtain vertical profiles of various minor constituents the characteristic absorption lines in 9 to 11 micron spectral range. Due to its high spectral resolution the lines can be resolved completely and data obtained are inverted to get vertical profiles using an inversion technique developed by the author. In the present communication the salient features of the laser heterodyne system and the results obtained are discussed in detail.

  11. Four absolute cavity radiometer (pyrheliometer) intercomparisons at New River, Arizona: radiometer standards

    Energy Technology Data Exchange (ETDEWEB)

    Estey, R.S.; Seaman, C.H.

    1981-07-01

    Four detailed intercomparisons were made for a number of models of cavity-type self-calibrating radiometers (pyrheliometers). Each intercomparison consisted of simultaneous readings of pyrheliometers at 30-second intervals in runs of 10 minutes, with at least 15 runs per intercomparison. Twenty-seven instruments were in at least one intercomparison, and five were in all four. Summarized results and all raw data are provided from the intercomparisons.

  12. Preparation of fluorescence nano -labeling material carbon quantum dots%纳米标记材料荧光碳点的制备

    Institute of Scientific and Technical Information of China (English)

    周尽晖; 金玲; 丁玲; 彭泽泽; 刘茂兰; 韩秀金; 赵庆祝; 贾旭升; 黄泽波

    2015-01-01

    The water -soluble fluorescent carbon quantum dots (CQDs)with glucose as a carbon source and polyethylene glycol (PEG)as dispersant and surface modifier,were synthesized in aqueous medium by microwave irradiation and hydrothermal methods respectively in order to explore the preparation of CQDs.The effect of reaction temperature,time,PEG/glucose molar ratios and pH value on the fluorescence properties of CQDs were discussed by using orthogonal experiment method.The results suggest the influence factors from main to secondary are the reaction time,reactant mole ratio and reaction temperature.The reaction temperature 180 ℃,reaction time 2.5 min,PEG -200 /glucose molar ratio 6 ∶1 and pH =9 are the optimal condition of microwave synthesis of CQDs.And under the resulting optimized conditions,the optical properties of CQDs obtained by the hydrothermal and microwave irradiation two methods are compared preliminary.The results show that the performance of carbon quantum dots prepared by hydrothermal method is superior to that of microwave method.But the two preparation methods of fluorescent CQDs have both good fluorescence properties.They can be used in the field of fluorescent labeling.%以葡萄糖为碳源,以聚乙二醇(PEG)为分散剂和表面修饰剂,采用微波法和水热法2种加热方法,探索了水溶性荧光纳米碳量子点(Carbon Quantum Dots,CQDs)的制备;探讨了碳量子点制备过程中反应温度、反应时间、PEG/葡萄糖摩尔比和 pH 值对碳量子点荧光性能的影响.实验结果表明,微波法合成碳量子点的影响因素的排列顺序为:反应时间>反应物摩尔比>反应温度,反应时间为2.5 min、摩尔比 n(PEG -200):n(葡萄糖)=6∶1、反应温度为180℃,pH =9为微波法合成荧光碳量子点的最优条件,并在此优化条件下,对微波法和水热法制备的碳量子点的光学性质进行了初步比较,结果显示,水热法制

  13. Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

    Directory of Open Access Journals (Sweden)

    Sebastián Pantoja

    2009-08-01

    Full Text Available The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers’ outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called “baseline errors” associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver’s output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.

  14. Calibration of electron cyclotron emission radiometer for KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Kogi, Y. [Fukuoka Institute of Technology, Fukuoka 811-0295 (Japan); Jeong, S. H. [Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of); Lee, K. D.; Kwon, M. [National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Akaki, K.; Mase, A. [KASTEC, Kyushu University, Kasuga 816-8580 (Japan); Kuwahara, D. [Tokyo Institute of Technology, Tokyo 152-8550 (Japan); Yoshinaga, T.; Nagayama, Y.; Kawahata, K. [National Institute for Fusion Science, Toki 509-5292 (Japan)

    2010-10-15

    We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.

  15. Calibration of electron cyclotron emission radiometer for KSTAR.

    Science.gov (United States)

    Kogi, Y; Jeong, S H; Lee, K D; Akaki, K; Mase, A; Kuwahara, D; Yoshinaga, T; Nagayama, Y; Kwon, M; Kawahata, K

    2010-10-01

    We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.

  16. An airborne microwave radiometer and measurements of cloud liquid water

    Institute of Scientific and Technical Information of China (English)

    LEI Hengchi; JIN Dezhen; WEI Chong; SHEN Zhilai

    2003-01-01

    A single-channel (9.5 mm) airborne microwave radiometer with one antenna is developed. The retrieval methods and primary observation results of cloud liquid water and super-cooled cloud liquid water are discussed. The aircraft experiments show that the cloud liquid water and super-cooled liquid water can be sensitively monitored at some level of accuracy by the radiometer. The results of cloud liquid water content are reasonable and correspond well with the surface radar echo intensity. The design of the airborne radiometer and its retrieval methods are feasible, giving it application value.

  17. Aquarius L-Band Radiometers Calibration Using Cold Sky Observations

    Science.gov (United States)

    Dinnat, Emmanuel P.; Le Vine, David M.; Piepmeier, Jeffrey R.; Brown, Shannon T.; Hong, Liang

    2015-01-01

    An important element in the calibration plan for the Aquarius radiometers is to look at the cold sky. This involves rotating the satellite 180 degrees from its nominal Earth viewing configuration to point the main beams at the celestial sky. At L-band, the cold sky provides a stable, well-characterized scene to be used as a calibration reference. This paper describes the cold sky calibration for Aquarius and how it is used as part of the absolute calibration. Cold sky observations helped establish the radiometer bias, by correcting for an error in the spillover lobe of the antenna pattern, and monitor the long-term radiometer drift.

  18. Preparation and evaluation of modified composition for lyophilized kits of [Cu(MIBI4]BF4 for [99mTc] technetium labeling

    Directory of Open Access Journals (Sweden)

    Marisa de Jesus de C. Lima

    2005-10-01

    Full Text Available The [Cu(MIBI4]BF4 complex was synthesized and different formulations for lyophilized kits that could be cost-effectively used with different routines in nuclear medicine laboratories were investigated. In one preparation the kit components were kept similar to the Cardiolite® , except that the SnCl2.2H2O concentration was increased to 0.150 mg. In a second formulation, component concentrations were reduced to 1/5 of the original value and the SnCl2.2H2O concentration was adjusted to 0.04 mg. These products were labeled with maximum activities of 55.5 GBq and 8.14 GBq, respectively, and have shown an average radiochemical purity of 95 %. Biodistribution of the products was assessed by dissection in mice and in rabbits, and did not show any statistical difference when compared to Cardiolite®. In the synthesis of [Cu(MIBI4]BF4 a new procedure was introduced for the synthesis of N-(2-methyl-propenyl-formamide, with the use of microwave radiation as heat source. This modification reduced the reaction time to 25 seconds, while maintaining a yield of 68%.Neste trabalho são apresentados dados relativos a síntese do complexo [Cu(MIBI4]BF4 e à utilização do mesmo para produção de kit liofilizado para obtenção do radiofármaco [[99mTc](MIBI6]+. No processo de síntese foi utilizado radiação de microondas como fonte de aquecimento em uma etapa do processo, permitindo que a reação fosse executada em 25 segundos, obtendo rendimento de 68 %. Na preparação dos kits liofilizados, um deles denominado FULL, nos quais a quantidade dos componentes foi mantida igual ao produto comercial Cardiolite®, e outro denominado FRACTION, nos quais as quantidades foram reduzidas a 1/5 do total, foram adicionadas quantidades extras de SnCl2.2H2O. Deste modo, tornou-se possível marcar os kits liofilizados com atividades máximas de 55,5 GBq e 8,14 GBq, respectivamente. A biodistribuição dos produtos marcados, em camundongos e coelhos, não mostrou diferen

  19. Multifilter Rotating Shadowband Radiometer (MFRSR) Handbook With subsections for derivative instruments: Multifilter Radiometer (MFR) Normal Incidence Multifilter Radiometer (NIMFR)

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, Gary B [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Michalsky, Joseph J [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.

    2016-03-01

    The visible Multifilter Rotating Shadowband Radiometer (MFRSR) is a passive instrument that measures global and diffuse components of solar irradiance at six narrowband channels and one open, or broadband, channel (Harrison et al. 1994). Direct irradiance is not a primary measurement, but is calculated using diffuse and global measurements. To collect one data record, the MFRSR takes measurements at four different shadowband positions. The first measurement is taken with the shadowband in the nadir (home) position. The next three measurements are, in order, the first side-band, sun-blocked, and second side-band. The side-band measurements are used to correct for the portion of the sky obscured by the shadowband. The nominal wavelengths of the narrowband channels are 415, 500, 615, 673, 870, and 940 nm. From such measurements, one may infer the atmosphere’s aerosol optical depth at each wavelength. In turn, these optical depths may be used to derive information about the column abundances of ozone and water vapor (Michalsky et al. 1995), as well as aerosol (Harrison and Michalsky 1994) and other atmospheric constituents.

  20. Next generation along track scanning radiometer - SLSTR

    Science.gov (United States)

    Frerick, J.; Nieke, J.; Mavrocordatos, C.; Berruti, B.; Donlon, C.; Cosi, M.; Engel, W.; Bianchi, S.; Smith, Dave

    2012-10-01

    Since 1991, along track scanning radiometers (A)ATSR have been flown on a series of satellite platforms. These instruments use an along-track scanning design that provides two views of the same earth target through different atmospheric paths. Dual-view multispectral measurements can be used to derive an accurate atmospheric correction when retrieving geophysical parameters such as Sea Surface Temperature (SST). In addition, the (A)ATSR family of instruments use actively cooled detector systems and two precision calibration blackbody targets to maintain and manage on-board calibration. Visible channel calibration is implemented using a solar diffuser viewed once per orbit. As a consequence of these design features, resulting data derived from (A)ATSR instruments is both accurate and well characterized. After 10 years of Service the ENVISAT platform was lost in early 2012 asnd AATSR operations stopped. The Global Monitoring for Environment and Security (GMES) Sentinel-3 "Sea Land Surface Temperature Radiometer" (SLSTR) instrument is the successor to the AATSR family of instruments and is expected to launch in April 2014. The challenge for SLSTR is to develop and deliver a new instrument with identical or improved performance to that of the (A)ATSR family. The SLSTR design builds on the heritage features of the (A)ATSR with important extensions to address GMES requirements. SLSTR maintains the main instrument principles (along-track scanning, a two point infrared on-board radiometric calibration, actively cooled detectors, solar diffuser). The design also includes more spectral channels including additional bands at 1.3 and 2.2 μm providing enhanced cloud detection, dedicated fire channels, an increase of dual view swath from 500 to 740 km, an increase in the nadir swath of 1400 km. The increase in swath has led to, a new optical front-end design incorporating two rotating scan mirrors (with encoders to provide pointing knowledge) and an innovative flip mechanism to

  1. Nutrition Labeling

    DEFF Research Database (Denmark)

    Grunert, Klaus G

    2013-01-01

    because consumers will avoid products that the label shows to be nutritionally deficient, but also because food producers will try to avoid marketing products that appear, according to the label, as nutritionally problematic, for example, because of a high content of saturated fat or salt. Nutrition......Nutrition labeling refers to the provision of information on a food product’s nutritional content on the package label. It can serve both public health and commercial purposes. From a public health perspective, the aim of nutrition labeling is to provide information that can enable consumers...... to make healthier choices when choosing food products. Nutrition labeling is thus closely linked to the notion of the informed consumer, that chooses products according to their aims, on the basis of the information at their disposal. Because many consumers are assumed to be interested in making healthy...

  2. Nutrition Labeling

    DEFF Research Database (Denmark)

    Grunert, Klaus G

    2013-01-01

    because consumers will avoid products that the label shows to be nutritionally deficient, but also because food producers will try to avoid marketing products that appear, according to the label, as nutritionally problematic, for example, because of a high content of saturated fat or salt. Nutrition......Nutrition labeling refers to the provision of information on a food product’s nutritional content on the package label. It can serve both public health and commercial purposes. From a public health perspective, the aim of nutrition labeling is to provide information that can enable consumers...... to make healthier choices when choosing food products. Nutrition labeling is thus closely linked to the notion of the informed consumer, that chooses products according to their aims, on the basis of the information at their disposal. Because many consumers are assumed to be interested in making healthy...

  3. Influence of antiseptic on the impurities in the preparation of dimercaptosuccinic labelled with {sup 99m}Tc; Influence des antiseptiques sur la presence d'impuretes dans la preparation de l'acide dimercaptosuccinique marque au 99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Metaye, T.; Rosenberg, T.; Perdrisot, R. [CHU de Poitiers, Service de medecine nucleaire et biophysique, 86 (France)

    2010-07-01

    Purpose: antiseptic solutions are used to disinfect the rubber stoppers on the bottles of radiopharmaceutical. Small amounts of these solutions can pass into the bottle when the cap is pricked to inject the {sup 99m}Tc. After finding in a patient a suboptimal labelling using biseptin, we studied the effect of various antiseptics on the presence of impurities in the preparation of the dimercaptosuccinic acid labelled with {sup 99m}Tc ({sup 99m}Tc-D.M.S.A.). Conclusions: We recommend using 70% isopropanol or modified alcohol Cooper instead of biseptin to disinfect the D.M.S.A. bottles caps. (N.C.)

  4. Preparation, biodistribution, and dosimetry of {sup 188}Re-Labeled MoAb ior cea1 and its f(ab'){sub 2} fragments by avidin-biotin strategy

    Energy Technology Data Exchange (ETDEWEB)

    Ferro-Flores, Guillermina E-mail: gff@nuclear.inin.mx; Pimentel-Gonzalez, Gilmara; Gonzalez-Zavala, Maria Antonia; Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Tendilla, Jose I.; Croft, Barbara Y

    1999-01-01

    The biotinylated monoclonal antibody (MoAb) ior cea1 and its F(ab'){sub 2} fragments were labeled with Re-188 by combination of avidin-biotin strategy. {sup 188}Re-MoAb, {sup 188}Re-MoAb-biotin, {sup 188}Re-F(ab'){sub 2}, and {sup 188}Re-F(ab'){sub 2}-biotin preparations were produced for these studies with specific activities of 1.30{+-}0.18 GBq/mg and from instant freeze-dried kit formulations using ethane-1-hydroxy-1,1-diphosphonic acid (EHDP) as a weak competing ligand. There were no significant differences (p>0.05) between the biodistribution in mice of biotinylated and unbiotinylated {sup 188}Re-labeled immunoconjugates. When avidin was injected as a chase after injection of {sup 188}Re-MoAb-biotin or {sup 188}Re-F(ab'){sub 2}-biotin, the blood radioactivity level decreased approximately 75% (cumulated activity) and the effective dose decreased almost 25% with respect to that of the radioimmunoconjugates in which the chase effect was not used. Our results suggest that {sup 188}Re-labeled biotinylated MoAb ior cea1 and its F(ab'){sub 2} fragments prepared by this method are stable complexes in vivo.

  5. Calibration plan for the sea and land surface temperature radiometer

    Science.gov (United States)

    Smith, David L.; Nightingale, Tim J.; Mortimer, Hugh; Middleton, Kevin; Edeson, Ruben; Cox, Caroline V.; Mutlow, Chris T.; Maddison, Brian J.

    2013-10-01

    The Sea and Land Surface Temperature Radiometer (SLSTR) to be flown on ESA's Sentinel-3 mission is a multichannel scanning radiometer that will continue the 21-year datasets of the Along Track Scanning Radiometer (ATSR) series. As its name implies, measurements from SLSTR will be used to retrieve global sea surface temperatures to an uncertainty of SLSTR instrument, infrared calibration sources and alignment equipment. The calibration rig has been commissioned and results of these tests will be presented. Finally the authors will present the planning for the on-orbit monitoring and calibration activities to ensure that calibration is maintained. These activities include vicarious calibration techniques that have been developed through previous missions, and the deployment of ship-borne radiometers.

  6. Submillimeter-Wave Radiometer Technology for Earth Remote Sensing Applications

    Science.gov (United States)

    Siegel, P.

    2000-01-01

    Recent innovations in ultra-high frequency, semiconductor device/component technology have enabled both traditional and new applications for space-borne millimeter- and submillimeter-wave heterodyne radiometer instruments.

  7. Wide-range logarithmic radiometer for measuring high temperatures

    Science.gov (United States)

    Liston, E. M.

    1971-01-01

    Filter radiometer utilizing photomultiplier circuit, in which a direct-coupled amplifier varies dynode voltage to maintain constant anode current, measures rapid variations of temperature of white-hot charred body at 2000 K to 3000 K.

  8. Multi-angle Imaging SpectroRadiometer (MISR)

    Data.gov (United States)

    National Aeronautics and Space Administration — The Multi-angle Imaging SpectroRadiometer (MISR) was successfully launched into sun-synchronous polar orbit aboard Terra, NASA's first Earth Observing System (EOS)...

  9. Sources of errors in the measurements of underwater profiling radiometer

    Digital Repository Service at National Institute of Oceanography (India)

    Silveira, N.; Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; Lotlikar, A.

    There are various sources of errors from the measurements of optical parameters using a radiometer, which can be classified as mode of deployment, instrument and environment. The errors from the deployment are primarily from the ship...

  10. Multifilter Rotating Shadowband Radiometer (MFRSR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, GB; Michalsky, JJ

    2011-02-07

    The visible Multifilter Rotating Shadowband Radiometer (MFRSR) is a passive instrument that measures global and diffuse components of solar irradiance at six narrowband channels and one open, or broadband, channel (Harrison et al. 1994). Direct irradiance is not a primary measurement, but is calculated using the diffuse and global measurements. To collect one data record, the MFRSR takes measurements at four different shadowband positions. The first measurement is taken with the shadowband in the nadir (home) position. The next three measurements are, in order, the first side-band, sun-blocked, and second side-band. The side-band measurements are used to correct for the portion of the sky obscured by the shadowband. The nominal wavelengths of the narrowband channels are 415, 500, 615, 673, 870, and 940 nm. From such measurements, one may infer the atmosphere's aerosol optical depth at each wavelength. In turn, these optical depths may be used to derive information about the column abundances of ozone and water vapor (Michalsky et al. 1995), as well as aerosol (Harrison and Michalsky 1994) and other atmospheric constituents.

  11. Multifilter Rotating Shadowband Radiometer (MFRSR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, GB; Michalsky, JJ

    2011-02-07

    The visible Multifilter Rotating Shadowband Radiometer (MFRSR) is a passive instrument that measures global and diffuse components of solar irradiance at six narrowband channels and one open, or broadband, channel (Harrison et al. 1994). Direct irradiance is not a primary measurement, but is calculated using the diffuse and global measurements. To collect one data record, the MFRSR takes measurements at four different shadowband positions. The first measurement is taken with the shadowband in the nadir (home) position. The next three measurements are, in order, the first side-band, sun-blocked, and second side-band. The side-band measurements are used to correct for the portion of the sky obscured by the shadowband. The nominal wavelengths of the narrowband channels are 415, 500, 615, 673, 870, and 940 nm. From such measurements, one may infer the atmosphere's aerosol optical depth at each wavelength. In turn, these optical depths may be used to derive information about the column abundances of ozone and water vapor (Michalsky et al. 1995), as well as aerosol (Harrison and Michalsky 1994) and other atmospheric constituents.

  12. A novel L-band polarimetric radiometer featuring subharmonic sampling

    DEFF Research Database (Denmark)

    Rotbøll, J.; Søbjærg, Sten Schmidl; Skou, Niels

    2003-01-01

    A novel L-band radiometer trading analog components for digital circuits has been designed, built and operated. It is a fully polarimetric radiometer of the correlation type, and it is based on the subharmonic sampling principle in which the L-band signal is directly sampled by a fast A to D...... converter at a frequency well below L-band. Overall stability has been a design driver, as the instrument is intended for airborne measurements of polarimetric sea signatures....

  13. L-Band Polarimetric Correlation Radiometer with Subharmonic Sampling

    DEFF Research Database (Denmark)

    Rotbøll, Jesper; Søbjærg, Sten Schmidl; Skou, Niels

    2001-01-01

    A novel L-band radiometer trading analog complexity for digital ditto has been designed and built. It is a fully polarimetric radiometer of the correlation type and it is based on the sub-harmonic sampling principle in which the L-band signal is directly sampled by a fast A to D converter...... at a frequency well below L-band. Stability has been a design driver, and the instrument is intended for airborne measurements of polarimetric sea signatures...

  14. Multibeam 1.4-GHz Pushbroom Microwave Radiometer

    Science.gov (United States)

    Lawrence, Roland W.; Bailey, Marion C.; Harrington, Richard F.; Hearn, Chase P.; Wells, John G., Jr.; Stanley, William L.

    1990-01-01

    Airborne prototype of multiple-beam pushbroom microwave radiometer (PBMR) developed to advance radiometric technology necessary for remote sensing of geophysical parameters. Instrument used in several joint Langley Research Center/United States Department of Agriculture soil-moisture flight experiments in Virginia, Texas, and California. Data from experiments used to modify, develop, and verify algorithms used to predict soil moisture from remote-sensing measurements. Image data useful in study of effects of characters of beams on radiometer imaging data.

  15. Sustainability Labeling

    NARCIS (Netherlands)

    Dam, van Y.K.

    2017-01-01

    Sustainability labeling originated from a need to protect the identity of alternative systems of food production and to increase market transparency. From the 1980s onwards sustainability labeling has changed into a policy instrument replacing direct government regulation of the food market, and a

  16. Preparation of Au-Pt nanostructures by combining top-down with bottom-up strategies and application in label-free electrochemical immunosensor for detection of NMP22.

    Science.gov (United States)

    Jia, Hongying; Gao, Picheng; Ma, Hongmin; Wu, Dan; Du, Bin; Wei, Qin

    2015-02-01

    A novel label-free amperometric immunosensor for sensitive detection of nuclear matrix protein 22 (NMP22) was developed based on Au-Pt bimetallic nanostructures, which were prepared by combining top-down with bottom-up strategies. Nanoporous gold (NPG) was prepared by "top-down" dealloying of commercial Au/Ag alloy film. After deposition of NPG on an electrode, Pt nanoparticles (PtNPs) were further decorated on NPG by "bottom-up" electrodeposition. The prepared bimetallic nanostructures combine the merits of both NPG and PtNPs, and show a high electrocatalytic activity towards the reduction of H2O2. The label-free immunosensor was constructed by directly immobilizing antibody of NMP22 (anti-NMP22) on the surface of bimetallic nanostructures. The immunoreaction induced amperometric response could be detected and negatively correlated to the concentration of NMP22. Bimetallic nanostructure morphologies and detection conditions were investigated to obtain the best sensing performance. Under the optimal conditions, a linear range from 0.01ng/mL to 10ng/mL and a detection limit of 3.33pg/mL were obtained. The proposed immunosensor showed high sensitivity, good selectivity, stability, reproducibility, and regeneration for the detection of NMP22, and it was evaluated in urine samples, receiving satisfactory results.

  17. Preparation and Evaluation of 99mTc-labeled anti-CD11b Antibody Targeting Inflammatory Microenvironment for Colon Cancer Imaging.

    Science.gov (United States)

    Cheng, Dengfeng; Zou, Weihong; Li, Xiao; Xiu, Yan; Tan, Hui; Shi, Hongcheng; Yang, Xiangdong

    2015-06-01

    CD11b, an active constituent of innate immune response highly expressed in myeloid-derived suppressor cells (MDSCs), can be used as a marker of inflammatory microenvironment, particularly in tumor tissues. In this research, we aimed to fabricate a (99m)Tc-labeled anti-CD11b antibody as a probe for CD11b(+) myeloid cells in colon cancer imaging with single-photon emission computed tomography (SPECT). In situ murine colon tumor model was established in histidine decarboxylase knockout (Hdc(-/-)) mice by chemicals induction. (99m)Tc-labeled anti-CD11b was obtained with labeling yields of over 30% and radiochemical purity of over 95%. Micro-SPECT/CT scans were performed at 6 h post injection to investigate biodistributions and targeting of the probe. In situ colonic neoplasma as small as 3 mm diameters was clearly identified by imaging; after dissection of the animal, anti-CD11b immunofluorescence staining was performed to identify infiltration of CD11b+ MDSCs in microenvironment of colonic neoplasms. In addition, the images displayed intense signal from bone marrow and spleen, which indicated the origin and migration of CD11b(+) MDSCs in vivo, and these results were further proved by flow cytometry analysis. Therefore, (99m)Tc-labeled anti-CD11b SPECT displayed the potential to facilitate the diagnosis of colon tumor in very early stage via detection of inflammatory microenvironment. © 2014 John Wiley & Sons A/S.

  18. Multicapillary SDS-gel electrophoresis for the analysis of fluorescently labeled mAb preparations: a high throughput quality control process for the production of QuantiPlasma and PlasmaScan mAb libraries.

    Science.gov (United States)

    Székely, Andrea; Szekrényes, Akos; Kerékgyártó, Márta; Balogh, Attila; Kádas, János; Lázár, József; Guttman, András; Kurucz, István; Takács, László

    2014-08-01

    Molecular heterogeneity of mAb preparations is the result of various co- and post-translational modifications and to contaminants related to the production process. Changes in molecular composition results in alterations of functional performance, therefore quality control and validation of therapeutic or diagnostic protein products is essential. A special case is the consistent production of mAb libraries (QuantiPlasma™ and PlasmaScan™) for proteome profiling, quality control of which represents a challenge because of high number of mAbs (>1000). Here, we devise a generally applicable multicapillary SDS-gel electrophoresis process for the analysis of fluorescently labeled mAb preparations for the high throughput quality control of mAbs of the QuantiPlasma™ and PlasmaScan™ libraries. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Utilization of a novel electrochemical {sup 90}Sr/{sup 90}Y generator for the preparation of {sup 90}Y-labeled RGD peptide dimer in clinically relevant dose

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Sudipta; Chakravarty, Rubel; Pillai, Maroor Raghavan Ambikalmajan; Dash, Ashutosh [Bhabha Atomic Research Centre, Mumbai (India). Radiopharmaceuticals Div.; Sarma, Haladhar Dev [Bhabha Atomic Research Centre, Mumbai (India). Radiation Biology and Health Sciences Div.

    2014-09-01

    The work reported in this paper provides a systematic study towards the development of an optimized strategy for preparation of a clinically relevant dose of {sup 90}Y-labeled dimeric RGD peptide derivative, DOTA-E[c(RGDfK)]{sub 2} [DOTA-(RGD){sub 2}] for in vivo targeted therapy utilizing {sup 90}Y obtained from a novel electrochemical {sup 90}Sr/{sup 90}Y generator. The performance of the generator was evaluated to ensure its suitability for providing {sup 90}Y in adequate quantity and purity required for formulation of clinically relevant dose for PRRT. {sup 90}Y-DOTA-(RGD){sub 2} was synthesized in high yield (86.2 ± 2.5%) and radiochemical purity (98.4 ± 0.5%) using clinically relevant dose (∝ 3.8 GBq) of {sup 90}Y. In vitro stability studies revealed that the radiolabeled conjugate retained its radiochemical purity in normal saline and human serum. Preliminary biodistribution studies carried out in C57/BL6 mice bearing melanoma tumors showed that the preparation exhibited significant tumor uptake (5.30 ± 0.78% of injected activity at 30 min post-injection) with good tumor to background ratio. The optimized radiolabeling protocol seems to be an attractive strategy which is largely viewed as a springboard to realize scope of developing {sup 90}Y labeled cyclic RGD peptides for targeted therapy of tumors over-expressing integrin-α{sub ν}β{sub 3} receptors. (orig.)

  20. Radiometer effect in space missions to test the equivalence principle

    Science.gov (United States)

    Nobili, A. M.; Bramanti, D.; Comandi, G.; Toncelli, R.; Polacco, E.; Catastini, G.

    2001-05-01

    Experiments to test the equivalence principle in space by testing the universality of free fall in the gravitational field of the Earth have to take into account the radiometer effect, caused by temperature differences in the residual gas inside the spacecraft as it is exposed to the infrared radiation from Earth itself. We report the results of our evaluation of this effect for the three proposed experiments currently under investigation by space agencies: μSCOPE, STEP, and GG. It is found that in μSCOPE, which operates at room temperature, and even in STEP, where the effect is greatly reduced by means of very low temperatures, the radiometer effect is a serious limitation to the achievable sensitivity. Instead, by axially spinning the whole spacecraft and with an appropriate choice of the sensitivity axes-as proposed in GG-the radiometer effect averages out and becomes unimportant even at room temperature.

  1. A novel ternary ligand system useful for preparation of cationic (99m)Tc-diazenido complexes and (99m)Tc-labeling of small biomolecules.

    Science.gov (United States)

    Kim, Young-Seung; He, Zhengjie; Hsieh, Wen-Yuan; Liu, Shuang

    2006-01-01

    This report describes a novel ternary ligand system composed of a phenylhydrazine, a crown ether-containing dithiocarbamate (DTC), and a PNP-type bisphosphine (PNP). The combination of three different ligands with (99m)Tc results in cationic (99m)Tc-diazenido complexes, [(99m)Tc(NNAr)(DTC)(PNP)]+, with potential radiopharmaceuticals for heart imaging. Synthesis of cationic (99m)Tc-diazenido complexes can be accomplished in two steps. For example, the reaction of phenylhydrazine with (99m)TcO4- at 100 degrees C in the presence of excess stannous chloride and 1,2-diaminopropane-N,N,N',N'-tetraacetic acid (PDTA) results in the [(99m)Tc(NNPh)(PDTA)n] intermediate, which then reacts with sodium N-(dithiocarbamato)-2-aminomethyl-15-Crown-5 (L4) and N,N-bis[2-(bis(3-ethoxypropyl)phosphino)ethyl]ethoxyethylamine (PNP6) at 100 degrees C for 15 min to give the complex, [(99m)Tc(NNPh)(L4)(PNP6)]+ in high yield (>90%). Cationic complexes [(99m)Tc(NNPh)(DTC)(PNP)]+ are stable for > or = 6 h. Their composition was determined to be 1:1:1:1 for Tc:NNPh:DTC:PNP using the mixed-ligand experiments on the tracer ((99m)Tc) level and was further confirmed by the ESI-MS spectral data of a model compound [Re(NNPh)(L4)(L6)]+. It was found that both DTCs and bisphosphines have a significant impact on the lipophilicity of their cationic (99m)Tc-diazenido complexes. Results from a (99m)Tc-labeling efficiency experiment showed that 4-hydrazinobenzoic acid (HYBA) might be useful as a bifunctional coupling agent for (99m)Tc-labeling of small biomolecules. However, the (99m)Tc-labeling efficiency of HYBA is much lower than that of 6-hydrazinonicotinic acid (HYNIC) with tricine and trisodium triphenylphosphine-3,3',3''-trisulfonate (TPPTS) as coligands.

  2. ESTAR - A synthetic aperture microwave radiometer for measuring soil moisture

    Science.gov (United States)

    Le Vine, D. M.; Griffis, A.; Swift, C. T.; Jackson, T. J.

    1992-01-01

    The measurement of soil moisture from space requires putting relatively large microwave antennas in orbit. Aperture synthesis, an interferometric technique for reducing the antenna aperture needed in space, offers the potential for a practical means of meeting these requirements. An aircraft prototype, electronically steered thinned array L-band radiometer (ESTAR), has been built to develop this concept and to demonstrate its suitability for the measurement of soil moisture. Recent flights over the Walnut Gulch Watershed in Arizona show good agreement with ground truth and with measurements with the Pushbroom Microwave Radiometer (PBMR).

  3. Cloud Absorption Radiometer Autonomous Navigation System - CANS

    Science.gov (United States)

    Kahle, Duncan; Gatebe, Charles; McCune, Bill; Hellwig, Dustan

    2013-01-01

    CAR (cloud absorption radiometer) acquires spatial reference data from host aircraft navigation systems. This poses various problems during CAR data reduction, including navigation data format, accuracy of position data, accuracy of airframe inertial data, and navigation data rate. Incorporating its own navigation system, which included GPS (Global Positioning System), roll axis inertia and rates, and three axis acceleration, CANS expedites data reduction and increases the accuracy of the CAR end data product. CANS provides a self-contained navigation system for the CAR, using inertial reference and GPS positional information. The intent of the software application was to correct the sensor with respect to aircraft roll in real time based upon inputs from a precision navigation sensor. In addition, the navigation information (including GPS position), attitude data, and sensor position details are all streamed to a remote system for recording and later analysis. CANS comprises a commercially available inertial navigation system with integral GPS capability (Attitude Heading Reference System AHRS) integrated into the CAR support structure and data system. The unit is attached to the bottom of the tripod support structure. The related GPS antenna is located on the P-3 radome immediately above the CAR. The AHRS unit provides a RS-232 data stream containing global position and inertial attitude and velocity data to the CAR, which is recorded concurrently with the CAR data. This independence from aircraft navigation input provides for position and inertial state data that accounts for very small changes in aircraft attitude and position, sensed at the CAR location as opposed to aircraft state sensors typically installed close to the aircraft center of gravity. More accurate positional data enables quicker CAR data reduction with better resolution. The CANS software operates in two modes: initialization/calibration and operational. In the initialization/calibration mode

  4. Novel Low-Impact Integration of a Microwave Radiometer into Cloud Radar System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The radiometer channel will have significant filtering to reduce the contamination of the radar signal into the radiometer channels.The successful isolation between...

  5. A Novel Ternary Ligand System Useful for Preparation of Cationic 99mTc-Diazenido Complexes and 99mTc-Labeling of Small Biomolecules

    Science.gov (United States)

    Kim, Young-Seung; He, Zhengjie; Hsieh, Wen-Yuan; Liu, Shuang

    2008-01-01

    This report describes a novel ternary ligand system composed of a phenylhydrazine, a crown ether-containing dithiocarbamate (DTC) and a PNP-type bisphosphine (PNP). The combination of three different ligands with 99mTc results in cationic 99mTc-diazenido complexes,[99mTc(NNAr)(DTC)(PNP)]+, with potential radiopharmaceuticals for heart imaging. Synthesis of cationic 99mTc-diazenido complexes can be accomplished in two steps with high yield. For example, the reaction of phenylhydrazine with 99mTcO4− at 100 °C in the presence of excess stannous chloride and 1,2-diaminopropane-N,N,N’,N’-tetraacetic acid (PDTA) results in the [99mTc(NNPh)(PDTA)n] intermediate, which then reacts with sodium N-(dithiocarbamato)-2-aminimethyl-15-Crown-5 (L4) and N,N-bis[2-(bis(3-ethoxypropyl)phosphino)ethyl]ethoxy-ethylamine (PNP6) at 100 °C for 15 min to give the complex, [99mTc(NNPh)(L4)(PNP6)]+ in high yield (> 90%). Cationic complexes [99mTc(NNPh)(DTC)(PNP)]+ are stable for ≥6 h. Their composition was determined to be 1:1:1:1 for Tc:NNPh:DTC:PNP using the mixed-ligand experiments on the tracer (99mTc) level, and was further confirmed by the ESI-MS spectral data of a model compound [Re(NNPh)(L4)(L6)]+. It was found that both DTCs and bisphosphines have a significant impact on the lipophilicity of their cationic 99mTc-diazenido complexes. Results from a 99mTc-labeling efficiency experiment showed that 4-hydrazinobenzoic acid (HYBA) might be useful as a bifunctional coupling agent for 99mTc-labeling of small biomolecules. However, the 99mTc-labeling efficiency of HYBA is much lower than that of 6-hydrazinonicotinic acid (HYNIC) with tricine and trisodium triphenylphosphine-3,3’,3”-trisulfonate (TPPTS) as coligands. PMID:16536480

  6. Calibration of the solar UV radiometers in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Leszczynski, K.; Jokela, K.; Visuri, R.; Ylianttila, L. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland). Non-Ionizing Radiation Lab.

    1996-12-31

    In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

  7. Planck-LFI radiometers' spectral response

    Energy Technology Data Exchange (ETDEWEB)

    Zonca, A [INAF-IASF Milano, Via E. Bassini 15, 20133 Milano (Italy); Franceschet, C; Mennella, A; Bersanelli, M [Universita di Milano, Dipartimento di Fisica, Via G. Celoria 16, 20133 Milano (Italy); Battaglia, P; Silvestri, R [Thales Alenia Space Italia S.p.A., S.S. Padana Superiore 290, 20090 Vimodrone, Milano (Italy); Villa, F; Butler, R C; Cuttaia, F; Mandolesi, N [INAF-IASF Bologna, Via P. Gobetti 101, 40129 Bologna (Italy); D' Arcangelo, O [IFP-CNR, via Cozzi 53, 20125 Milano (Italy); Artal, E [Departamento de IngenierIa de Comunicaciones, Universidad de Cantabria, Avenida de los Castros s/n. 39005 Santander (Spain); Davis, R J [Jodrell Bank Centre for Astrophysics, Alan Turing Building, The University of Manchester, Manchester, M13 9PL (United Kingdom); Galeotta, S; Maris, M [INAF-OATs, Via G.B. Tiepolo 11, I-34131, Trieste (Italy); Hughes, N; Jukkala, P; Kilpiae, V-H [DA-Design Oy, Keskuskatu 29, FI-31600, Jokioinen (Finland); Laaninen, M [Ylinen Electronics Oy, Teollisuustie 9A, FIN-02700, Kauniainen (Finland); Mendes, L, E-mail: andrea.zonca@fisica.unimi.i [ESA - ESAC, Camino bajo del Castillo, s/n, Villanueva de la Canada 28692 Madrid (Spain)

    2009-12-15

    The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.

  8. Calibration of Hurricane Imaging Radiometer C-Band Receivers

    Science.gov (United States)

    Biswas, Sayak K.; Cecil, Daniel J.; James, Mark W.

    2017-01-01

    The laboratory calibration of airborne Hurricane Imaging Radiometer's C-Band multi-frequency receivers is described here. The method used to obtain the values of receiver frontend loss, internal cold load brightness temperature and injected noise diode temperature is presented along with the expected RMS uncertainty in the final calibration.

  9. Landmine detection with an imaging 94-GHz radiometer

    NARCIS (Netherlands)

    Groot, J.S.; Dekker, R.J.; Ewijk, L.J.

    1996-01-01

    We analyzed a time series of 94 GHz radiometer images of a sandbox with buried and unburied, metal and plastic AP and AT dummy mines. The images covered almost a complete 24 hour cycle, with both clear sky and rain conditions occurring. The AP nor the buried mines were visible at any time. The contr

  10. Microwave Radiometer – 3 Channel (MWR3C) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cadeddu, MP

    2012-05-04

    The microwave radiometer 3-channel (MWR3C) provides time-series measurements of brightness temperatures from three channels centered at 23.834, 30, and 89 GHz. These three channels are sensitive to the presence of liquid water and precipitable water vapor.

  11. Dense Focal Plane Arrays for Pushbroom Satellite Radiometers

    DEFF Research Database (Denmark)

    Iupikov, O. A.; Ivashina, M. V.; Pontoppidan, K.

    2014-01-01

    Performance of a dense focal plane array feeding an offset toroidal reflector antenna system is studied and discussed in the context of a potential application in multi-beam radiometers for ocean surveillance. We present a preliminary design of the array feed for the 5-m diameter antenna at X...

  12. Radio-frequency interference mitigating hyperspectral L-band radiometer

    Science.gov (United States)

    Toose, Peter; Roy, Alexandre; Solheim, Frederick; Derksen, Chris; Watts, Tom; Royer, Alain; Walker, Anne

    2017-02-01

    Radio-frequency interference (RFI) can significantly contaminate the measured radiometric signal of current spaceborne L-band passive microwave radiometers. These spaceborne radiometers operate within the protected passive remote sensing and radio-astronomy frequency allocation of 1400-1427 MHz but nonetheless are still subjected to frequent RFI intrusions. We present a unique surface-based and airborne hyperspectral 385 channel, dual polarization, L-band Fourier transform, RFI-detecting radiometer designed with a frequency range from 1400 through ≈ 1550 MHz. The extended frequency range was intended to increase the likelihood of detecting adjacent RFI-free channels to increase the signal, and therefore the thermal resolution, of the radiometer instrument. The external instrument calibration uses three targets (sky, ambient, and warm), and validation from independent stability measurements shows a mean absolute error (MAE) of 1.0 K for ambient and warm targets and 1.5 K for sky. A simple but effective RFI removal method which exploits the large number of frequency channels is also described. This method separates the desired thermal emission from RFI intrusions and was evaluated with synthetic microwave spectra generated using a Monte Carlo approach and validated with surface-based and airborne experimental measurements.

  13. Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Skou, Niels; Søbjærg, Sten Schmidl; Balling, Jan E.

    2008-01-01

    Two semi-conductor Active Cold Loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency was chosen, and the target noise temperature value was in the 50 to 100 K range. The ACLs are characterized in the operating temperature range 0 50...

  14. Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Søbjærg, Sten Schmidl; Skou, Niels; Balling, Jan E.

    2009-01-01

    Two semiconductor active cold loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency was chosen, and the target noise temperature value was in the 50-100-K range. The ACLs are characterized in the operating temperature range of 0deg...

  15. Performance Measurements on Active Cold Loads for Radiometer Calibration

    DEFF Research Database (Denmark)

    Skou, Niels; Søbjærg, Sten Schmidl; Balling, Jan E.

    2007-01-01

    Two semi-conductor Active Cold Loads (ACLs) to be used as cold references in spaceborne microwave radiometers have been developed. An X-band frequency has been chosen, and the target noise temperature value is in the 50 to 100 K range. The ACLs are to be characterized in the operating temperature...

  16. Measurement of small antenna reflector losses for radiometer calibration budget

    DEFF Research Database (Denmark)

    Skou, Niels

    1997-01-01

    Antenna reflector losses play an important role in the calibration budget for a microwave radiometer. If the losses are small, they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiation...

  17. The design of an in-water optical radiometer

    Digital Repository Service at National Institute of Oceanography (India)

    Desa, E.S.; Desa, B.A.E.; DeSa, E.J.

    and downwelling spectral irradiance over an effective dynamic range greater than six decades and with a spectral resolution of 2nm. The emergence of a new generation of radiometers is now practically possible with the advent of scientific grade CCD (charged couple...

  18. Labelling of benzocaine with tritium

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Sohail (Washington Univ., Seattle, WA (United States))

    1994-10-01

    A convenient method is described to label a local anesthetic, benzocaine, with tritium. The bromoester of para-aminobenzoic acid (PABA) was prepared from para-nitrotoluene and was reduced with tritium. The generation of isotopic hydrogen and labelling of benzocaine was achieved in one-step. A mixture of sodium borohydride (NaB[sup 3]H[sub 4]) with cobalt (II) chloride was used to generate tritium gas. 5% Pd/C was used as a catalyst. This constitutes the first report of tritium labelled benzocaine. (author).

  19. Radiometer effect in the μSCOPE space mission

    Science.gov (United States)

    Nobili, A. M.; Bramanti, D.; Comandi, G. L.; Toncelli, R.; Polacco, E.

    2002-12-01

    Space experiments to test the Equivalence Principle (EP) are affected by a systematic radiometer effect having the same signature as the target signal. In [PhRvD 63 (2001) 101101(R)] we have investigated this effect for the three proposed experiments currently under study by space agencies: μSCOPE, STEP and GG, setting the requirements to be met—on temperature gradients at the level of the test masses—for each experiment to reach its goal. We have now re-examined the radiometer effect in the case of μSCOPE and carried out a quantitative comparative analysis, on this issue, with the proposed heliocentric LISA mission for the detection of gravity waves. We find that, even assuming that the μSCOPE spacecraft and payload be built to meet all the challenging requirements of LISA, temperature gradients along its test masses would still make the radiometer effect larger than the target signal of an EP violation because of flying in the low geocentric orbit required for EP testing. We find no way to separate with certainty the radiometer systematic disturbance from the signal. μSCOPE is designed to fly a second accelerometer whose test masses have the same composition, in order to separate out systematic effects which—not being composition dependent like the signal—must be detected by both accelerometers. We point out that this accelerometer is in fact insensitive to the radiometer effect, just as it is to an EP violation signal, and therefore even having it onboard will not allow this disturbance to be separated out. μSCOPE is under construction and it is scheduled to fly in 2004. If it will detect a signal to the expected level, it will be impossible to establish with certainty whether it is due to the well known classical radiometer effect or else to a violation of the equivalence principle—which would invalidate General Relativity. The option to increase the rotation speed of the spacecraft (now set at about 10 -3 Hz) so as to average out the temperature

  20. A New Way to Demonstrate the Radiometer as a Heat Engine

    Science.gov (United States)

    Hladkouski, V. I.; Pinchuk, A. I.

    2015-01-01

    While the radiometer is readily available as a toy, A. E. Woodruff notes that it is also a very useful tool to help us understand how to resolve certain scientific problems. Many physicists think they know how the radiometer works, but only a few actually understand it. Here we present a demonstration that shows that a radiometer can be thought of…

  1. Design of a Push-Broom Multi-Beam Radiometer for Future Ocean Observations

    DEFF Research Database (Denmark)

    Cappellin, C.; Pontoppidan, K.; Nielsen, P. H.

    2015-01-01

    The design of a push-broom multi-beam radiometer for future ocean observations is described. The radiometer provides a sensitivity one order of magnitude higher than a traditional conical scanning radiometer, and has the big advantage of being fully stationary relative to the satellite platform...

  2. A New Way to Demonstrate the Radiometer as a Heat Engine

    Science.gov (United States)

    Hladkouski, V. I.; Pinchuk, A. I.

    2015-01-01

    While the radiometer is readily available as a toy, A. E. Woodruff notes that it is also a very useful tool to help us understand how to resolve certain scientific problems. Many physicists think they know how the radiometer works, but only a few actually understand it. Here we present a demonstration that shows that a radiometer can be thought of…

  3. Design and Development of the SMAP Microwave Radiometer Electronics

    Science.gov (United States)

    Piepmeier, Jeffrey R.; Medeiros, James J.; Horgan, Kevin A.; Brambora, Clifford K.; Estep, Robert H.

    2014-01-01

    The SMAP microwave radiometer will measure land surface brightness temperature at L-band (1413 MHz) in the presence of radio frequency interference (RFI) for soil moisture remote sensing. The radiometer design was driven by the requirements to incorporate internal calibration, to operate synchronously with the SMAP radar, and to mitigate the deleterious effects of RFI. The system design includes a highly linear super-heterodyne microwave receiver with internal reference loads and noise sources for calibration and an innovative digital signal processor and detection system. The front-end comprises a coaxial cable-based feed network, with a pair of diplexers and a coupled noise source, and radiometer front-end (RFE) box. Internal calibration is provided by reference switches and a common noise source inside the RFE. The RF back-end (RBE) downconverts the 1413 MHz channel to an intermediate frequency (IF) of 120 MHz. The IF signals are then sampled and quantized by high-speed analog-to-digital converters in the radiometer digital electronics (RDE) box. The RBE local oscillator and RDE sampling clocks are phase-locked to a common reference to ensure coherency between the signals. The RDE performs additional filtering, sub-band channelization, cross-correlation for measuring third and fourth Stokes parameters, and detection and integration of the first four raw moments of the signals. These data are packetized and sent to the ground for calibration and further processing. Here we discuss the novel features of the radiometer hardware particularly those influenced by the need to mitigate RFI.

  4. Columnar water vapor retrievals from multifilter rotating shadowband radiometer data

    Energy Technology Data Exchange (ETDEWEB)

    Alexandrov, Mikhail; Schmid, Beat; Turner, David D.; Cairns, Brian; Oinas, Valdar; Lacis, Andrew A.; Gutman, S.; Westwater, Ed R.; Smirnov, A.; Eilers, J.

    2009-01-26

    The Multi-Filter Rotating Shadowband Radiometer (MFRSR) measures direct and diffuse irradiances in the visible and near IR spectral range. In addition to characteristics of atmospheric aerosols, MFRSR data also allow retrieval of precipitable water vapor (PWV) column amounts, which are determined from the direct normal irradiances in the 940 nm spectral channel. The HITRAN 2004 spectral database was used in our retrievals to model the water vapor absorption. We present a detailed error analysis describing the influence of uncertainties in instrument calibration and spectral response, as well as those in available spectral databases, on the retrieval results. The results of our PWV retrievals from the Southern Great Plains (SGP) site operated by the DOE Atmospheric Radiation Measurement (ARM) Program were compared with correlative standard measurements by Microwave Radiometers (MWRs) and a Global Positioning System (GPS) water vapor sensor, as well as with retrievals from other solar radiometers (AERONET’s CIMEL, AATS-6). Some of these data are routinely available at the SGP’s Central Facility, however, we also used measurements from a wider array of instrumentation deployed at this site during the Water Vapor Intensive Observation Period (WVIOP2000) in September – October 2000. The WVIOP data show better agreement between different solar radiometers or between different microwave radiometers (both groups showing relative biases within 4%) than between these two groups of instruments, with MWRs values being consistently higher (up to 14%) than those from solar instruments. We also demonstrate the feasibility of using MFRSR network data for creation of 2D datasets comparable with the MODIS satellite water vapor product.

  5. Radiochemical Aspects of Receptor Scintigraphy: labeling with radiometals, optimisation and radiochemical purity

    NARCIS (Netherlands)

    E. de Blois (Erik)

    2014-01-01

    textabstract__Abstract__ Radioactieve peptiden zijn stoffen die gebruikt worden voor het in vivo in beeld brengen van kanker. Tumorcellen brengen vaak receptoren in overvloed tot expressie in en op de tumorcellen. Wanneer deze receptoren, aanwezig op de tumorcellen, binden met de radiopeptiden kunn

  6. Food labels

    DEFF Research Database (Denmark)

    Selsøe Sørensen, Henrik; Clement, Jesper; Gabrielsen, Gorm

    2012-01-01

    The food industry develops tasty and healthy food but fails to deliver the message to all consumers. The consumers’ background knowledge is essential for how they find and decode relevant elements in the cocktail of signs which fight for attention on food labels. In this exploratory study, we find...... evidence for dividing consumers into two profiles: one relying on general food knowledge and another using knowledge related to signpost labels. In a combined eyetracking and questionnaire survey we analyse the influence of background knowledge and identify different patterns of visual attention...... for the two consumer profiles. This underlines the complexity in choosing and designing the ‘right’ elements for a food package that consumers actually look at and are able to make rational use of. In spite of any regulation of food information provided by authorities, consumers will still be confronted...

  7. Underlying Surface Remote Sensing by the Microwave Radiometer with High Measurement Rate

    Directory of Open Access Journals (Sweden)

    Ubaichin Anton

    2016-01-01

    Full Text Available The paper describes a new approach to microwave radiometer design. The approach implies simultaneous using both modified zero measurement method and multi-receiver technique. Simultaneous using increases the operating characteristics of airborne microwave radiometers for aircrafts with self-contained power supply. The block diagram of the onboard Earth remote sensing microwave radiometric system is presented. The block diagram and operating timing diagrams of the designed radiometer are shown. An original technique to design a fiducial noise source for transfer characteristics is discussed. The advantages of the designed radiometer in comparison with the state of the art zero-type microwave radiometer are described.

  8. Neutron-capture therapy of human cancer: in vitro results on the preparation of boron-labeled antibodies to carcinoembryonic antigen.

    OpenAIRE

    Mizusawa, E; Dahlman, H L; Bennett, S. J.; Goldenberg, D M; Hawthorne, M F

    1982-01-01

    Two samples of 2-phenyl-1,2-dicarba-closo-[1-3H]dodecaborane(12) were prepared by treating 1-lithio-2-phenyl-1,2-dicarba-closo-dodecaborane(12) with 3H2O (0.1 and 5.0 Ci/ml, respectively). These tritiated phenylcarborane samples were subsequently converted to corresponding samples of p-[1,2-dicarba-closo-[1-3H]dodecaboran(12)-2-yl]benzenediazonium ion ([3H]DBD) suitable for azo-coupling reactions. Reaction of the two tritiated diazonium ion samples with 2-napthol resulted in the formation of ...

  9. Introduction to Pesticide Labels

    Science.gov (United States)

    Pesticide product labels provide critical information about how to safely and legally handle and use pesticide products. Unlike most other types of product labels, pesticide labels are legally enforceable. Learn about pesticide product labels.

  10. Food Label and You

    Medline Plus

    Full Text Available ... Products Food Home Food Ingredients, Packaging & Labeling Labeling & Nutrition The Food Label and You — Video Share Tweet ... FDA has issued final changes to update the Nutrition Facts label for packaged foods. For more information, ...

  11. Rotating shadowband radiometer development and analysis of spectral shortwave data

    Energy Technology Data Exchange (ETDEWEB)

    Michalsky, J.; Harrison, L.; Min, Q. [State Univ. of New York, Albany, NY (United States)] [and others

    1996-04-01

    Our goals in the Atmospheric Radiation Measurement (ARM) Program are improved measurements of spectral shortwave radiation and improved techniques for the retrieval of climatologically sensitive parameters. The multifilter rotating shadowband radiometer (MFRSR) that was developed during the first years of the ARM program has become a workhorse at the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) site, and it is widely deployed in other climate programs. We have spent most of our effort this year developing techniques to retrieve column aerosol, water vapor, and ozone from direct beam spectral measurements of the MFRSR. Additionally, we have had some success in calculating shortwave surface diffuse spectral irradiance. Using the surface albedo and the global irradiance, we have calculated cloud optical depths. From cloud optical depth and liquid water measured with the microwave radiometer, we have calculated effective liquid cloud particle radii. The rest of the text will provide some detail regarding each of these efforts.

  12. Narrow Field of View Zenith Radiometer (NFOV) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, C; Marshak, A; Hodges, G; Barnard, JC; Schmelzer, J

    2008-11-01

    The two-channel narrow field-of-view radiometer (NFOV2) is a ground-based radiometer that looks straight up and measures radiance directly above the instrument at wavelengths of 673 and 870 nm. The field-of-view of the instrument is 1.2 degrees, and the sampling time resolution is one second. Measurements of the NFOV2 have been used to retrieve optical properties for overhead clouds that range from patchy to overcast. With a one-second sampling rate of the NFOV2, faster than almost any other ARM Climate Research Facility (ACRF) instrument, we are able, for the first time, to capture changes in cloud optical properties at the natural time scale of cloud evolution.

  13. Quantitative Analysis of Spectral Impacts on Silicon Photodiode Radiometers: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D. R.

    2011-04-01

    Inexpensive broadband pyranometers with silicon photodiode detectors have a non-uniform spectral response over the spectral range of 300-1100 nm. The response region includes only about 70% to 75% of the total energy in the terrestrial solar spectral distribution from 300 nm to 4000 nm. The solar spectrum constantly changes with solar position and atmospheric conditions. Relative spectral distributions of diffuse hemispherical irradiance sky radiation and total global hemispherical irradiance are drastically different. This analysis convolves a typical photodiode response with SMARTS 2.9.5 spectral model spectra for different sites and atmospheric conditions. Differences in solar component spectra lead to differences on the order of 2% in global hemispherical and 5% or more in diffuse hemispherical irradiances from silicon radiometers. The result is that errors of more than 7% can occur in the computation of direct normal irradiance from global hemispherical irradiance and diffuse hemispherical irradiance using these radiometers.

  14. Thermoelectric temperature control system for the pushbroom microwave radiometer (PBMR)

    Science.gov (United States)

    Dillon-Townes, L. A.; Averill, R. D.

    1984-06-01

    A closed loop thermoelectric temperature control system is developed for stabilizing sensitive RF integrated circuits within a microwave radiometer to an accuracy of + or - 0.1 C over a range of ambient conditions from -20 C to +45 C. The dual mode (heating and cooling) control concept utilizes partial thermal isolation of the RF units from an instrument deck which is thermally controlled by thermoelectric coolers and thin film heaters. The temperature control concept is simulated with a thermal analyzer program (MITAS) which consists of 37 nodes and 61 conductors. A full scale thermal mockup is tested in the laboratory at temperatures of 0 C, 21 C, and 45 C to confirm the validity of the control concept. A flight radiometer and temperature control system is successfully flight tested on the NASA Skyvan aircraft.

  15. Offset balancing in pseudo-correlation radiometers for CMB measurements

    Science.gov (United States)

    Mennella, A.; Bersanelli, M.; Seiffert, M.; Kettle, D.; Roddis, N.; Wilkinson, A.; Meinhold, P.

    2003-11-01

    Radiometeric CMB measurements need to be highly stable and this stability is best obtained with differential receivers. The residual 1/f noise in the differential output is strongly dependent on the radiometer input offset which can be cancelled using various balancing strategies. In this paper we discuss a software method implemented in the PLANCK-LFI pseudo-correlation receivers which uses a tunable gain modulation factor, r, in the sky-load difference. Numerical simulations and experimental data show how proper tuning of the parameter r ensures a very stable differential output with knee frequencies of the order of few mHz. Various approaches to calculate r using the radiometer total power data are discussed with some examples relevant to PLANCK-LFI. Although the paper focuses on pseudo-correlation receivers and the examples are relative to PLANCK-LFI, the proposed method and its analysis is general and can be applied to a large class of differential radiometric receivers.

  16. Offset balancing in pseudo-correlation radiometers for CMB measurements

    CERN Document Server

    Mennella, A; Seiffert, M; Kettle, D; Roddis, N; Wilkinson, A; Meinhold, P; Mennella, Aniello; Bersanelli, Marco; Seiffert, Michael; Kettle, Danielle; Roddis, Neil; Wilkinson, Althea; Meinhold, Peter

    2003-01-01

    Radiometeric CMB measurements need to be highly stable and this stability is best obtained with differential receivers. The residual 1/f noise in the differential output is strongly dependent on the radiometer input offset which can be cancelled using various balancing strategies. In this paper we discuss a software method implemented in the Planck-LFI pseudo-correlation receivers which uses a tunable "gain modulation factor, r, in the sky-load difference. Numerical simulations and experimental data show how proper tuning of the parameter r ensures a very stable differential output with knee frequencies of the order of few mHz. Various approaches to calculate r using the radiometer total power data are discussed with some examples relevant to Planck-LFI. Although the paper focuses on pseudo-correlation receivers and the examples are relative to Planck-LFI, the proposed method and its analysis is general and can be applied to a large class of differential radiometric receivers.

  17. An improved outdoor calibration procedure for broadband ultraviolet radiometers.

    Science.gov (United States)

    Cancillo, M L; Serrano, A; Antón, M; García, J A; Vilaplana, J M; de la Morena, B

    2005-01-01

    This article aims at improving the broadband ultraviolet radiometer's calibration methodology. For this goal, three broadband radiometers are calibrated against a spectrophotometer of reference. Three different one-step calibration models are tested: ratio, first order and second order. The latter is proposed in order to adequately reproduce the high dependence on the solar zenith angle shown by the other two models and, therefore, to improve the calibration performance at high solar elevations. The proposed new second-order model requires no additional information and, thus, keeps the operational character of the one-step methodology. The models are compared in terms of their root mean square error and the most qualified is subsequently validated by comparing its predictions with the spectrophotometer measurements within an independent validation data subset. Results show that the best calibration is achieved by the second-order model, with a mean bias error and mean absolute bias error lower than 2.2 and 6.7%, respectively.

  18. Development and application of an automated precision solar radiometer

    Science.gov (United States)

    Qiu, Gang-gang; Li, Xin; Zhang, Quan; Zheng, Xiao-bing; Yan, Jing

    2016-10-01

    Automated filed vicarious calibration is becoming a growing trend for satellite remote sensor, which require a solar radiometer have to automatic measure reliable data for a long time whatever the weather conditions and transfer measurement data to the user office. An automated precision solar radiometer has been developed. It is used in measuring the solar spectral irradiance received at the Earth surface. The instrument consists of 8 parallel separate silicon-photodiode-based channels with narrow band-pass filters from the visible to near-IR regions. Each channel has a 2.0° full-angle Filed of View (FOV). The detectors and filters are temperature stabilized using a Thermal Energy Converter at 30+/-0.2°. The instrument is pointed toward the sun via an auto-tracking system that actively tracks the sun within a +/-0.1°. It collects data automatically and communicates with user terminal through BDS (China's BeiDou Navigation Satellite System) while records data as a redundant in internal memory, including working state and error. The solar radiometer is automated in the sense that it requires no supervision throughout the whole process of working. It calculates start-time and stop-time every day matched with the time of sunrise and sunset, and stop working once the precipitation. Calibrated via Langley curves and simultaneous observed with CE318, the different of Aerosol Optical Depth (AOD) is within 5%. The solar radiometer had run in all kinds of harsh weather condition in Gobi in Dunhuang and obtain the AODs nearly eight months continuously. This paper presents instrument design analysis, atmospheric optical depth retrievals as well as the experiment result.

  19. Measurement of small antenna reflector losses for radiometer calibration budget

    OpenAIRE

    Skou, Niels

    1997-01-01

    Antenna reflector losses play an important role in the calibration budget for a microwave radiometer. If the losses are small, they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiation. This paper describes how such measurements are carried out as well as a suitable experimental setup. The main reflector of the European Space Agency's MIMR system is used to demonstrate the principle

  20. Transfer function considerations for the CERES scanning radiometer

    Science.gov (United States)

    Manalo, N.; Smith, G. L.; Barkstrom, Bruce R.

    1991-01-01

    The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer will determine the radiation budget of the Earth on a regional basis over a number of years. The error in the reconstructed field is used as a design criterion for selecting design parameters for the instrument. The reconstruction error is comprised of errors due to aliasing, blurring and radiance equivalent noise of the instrument, and can be evaluated in terms of the transfer function of the system.

  1. A One-Dimensional Synthetic-Aperture Microwave Radiometer

    Science.gov (United States)

    Doiron, Terence; Piepmeier, Jeffrey

    2010-01-01

    A proposed one-dimensional synthetic- aperture microwave radiometer could serve as an alternative to either the two-dimensional synthetic-aperture radiometer described in the immediately preceding article or to a prior one-dimensional one, denoted the Electrically Scanned Thinned Array Radiometer (ESTAR), mentioned in that article. The proposed radiometer would operate in a pushbroom imaging mode, utilizing (1) interferometric cross-track scanning to obtain cross-track resolution and (2) the focusing property of a reflector for along-track resolution. The most novel aspect of the proposed system would be the antenna (see figure), which would include a cylindrical reflector of offset parabolic cross section. The reflector could be made of a lightweight, flexible material amenable to stowage and deployment. Other than a stowage/deployment mechanism, the antenna would not include moving parts, and cross-track scanning would not entail mechanical rotation of the antenna. During operation, the focal line, parallel to the cylindrical axis, would be oriented in the cross-track direction, so that placement of receiving/radiating elements at the focal line would afford the desired along-track resolution. The elements would be microwave feed horns sparsely arrayed along the focal line. The feed horns would be oriented with their short and long cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis to obtain fan-shaped beams having their broad and narrow cross-sectional dimensions parallel and perpendicular, respectively, to the cylindrical axis. The interference among the beams would be controlled in the same manner as in the ESTAR to obtain along-cylindrical- axis (cross-track) resolution and cross-track scanning.

  2. Accurate antenna reflector loss measurements for radiometer calibration budget

    DEFF Research Database (Denmark)

    Skou, Niels

    1996-01-01

    Antenna reflector losses may play an important role in the calibration budget for a microwave radiometer. If the losses are small they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiat...... radiation. The paper describes how such measurements are carried out as well as a suitable experimental set-up. The main reflector of the European Space Agency's MIMR system is used to demonstrate the principle...

  3. Ozone profiles above Kiruna from two ground-based radiometers

    Science.gov (United States)

    Ryan, Niall J.; Walker, Kaley A.; Raffalski, Uwe; Kivi, Rigel; Gross, Jochen; Manney, Gloria L.

    2016-09-01

    This paper presents new atmospheric ozone concentration profiles retrieved from measurements made with two ground-based millimetre-wave radiometers in Kiruna, Sweden. The instruments are the Kiruna Microwave Radiometer (KIMRA) and the Millimeter wave Radiometer 2 (MIRA 2). The ozone concentration profiles are retrieved using an optimal estimation inversion technique, and they cover an altitude range of ˜ 16-54 km, with an altitude resolution of, at best, 8 km. The KIMRA and MIRA 2 measurements are compared to each other, to measurements from balloon-borne ozonesonde measurements at Sodankylä, Finland, and to measurements made by the Microwave Limb Sounder (MLS) aboard the Aura satellite. KIMRA has a correlation of 0.82, but shows a low bias, with respect to the ozonesonde data, and MIRA 2 shows a smaller magnitude low bias and a 0.98 correlation coefficient. Both radiometers are in general agreement with each other and with MLS data, showing high correlation coefficients, but there are differences between measurements that are not explained by random errors. An oscillatory bias with a peak of approximately ±1 ppmv is identified in the KIMRA ozone profiles over an altitude range of ˜ 18-35 km, and is believed to be due to baseline wave features that are present in the spectra. A time series analysis of KIMRA ozone for winters 2008-2013 shows the existence of a local wintertime minimum in the ozone profile above Kiruna. The measurements have been ongoing at Kiruna since 2002 and late 2012 for KIMRA and MIRA 2, respectively.

  4. A Novel Miniature Wide-band Radiometer for Space Applications

    Science.gov (United States)

    Sykulska-Lawrence, Hanna

    2016-10-01

    Design, development and testing of a novel miniaturised infrared radiometer is described. The instrument opens up new possibilities in planetary science of deployment on smaller platforms - such as unmanned aerial vehicles and microprobes - to enable study of a planet's radiation balance, as well as terrestrial volcano plumes and trace gases in planetary atmospheres, using low-cost long-term observations. Thus a key enabling development is that of miniaturised, low-power and well-calibrated instrumentation.The paper reports advances in miniature technology to perform high accuracy visible / IR remote sensing measurements. The infrared radiometer is akin to those widely used for remote sensing for earth and space applications, which are currently either large instruments on orbiting platforms or medium-sized payloads on balloons. We use MEMS microfabrication techniques to shrink a conventional design, while combining the calibration benefits of large (>1kg) type radiometers with the flexibility and portability of a measures broadband (0.2 to 100um) upward and downward radiation fluxes, with built-in calibration capability, incorporating traceability to temperature standards such as ITS-90.The miniature instrument described here was derived from a concept developed for a European Space Agency study, Dalomis (Proc. of 'i-SAIRAS 2005', Munich, 2005), which involved dropping multiple probes into the atmosphere of Venus from a balloon to sample numerous parts of the complex weather systems on the planet. Data from such an in-situ instrument would complement information from a satellite remote sensing instrument or balloon radiosonde. Moreover, the addition of an internal calibration standard facilitates comparisons between datasets.One of the main challenges for a reduced size device is calibration. We use an in-situ method whereby a blackbody source is integrated within the device and a micromirror switches the input to the detector between the measured signal and the

  5. Source analysis of spaceborne microwave radiometer interference over land

    Institute of Scientific and Technical Information of China (English)

    Li GUAN; Sibo ZHANG

    2016-01-01

    Satellite microwave thermal emissions mixed with signals from active sensors are referred to as radiofrequency interference (RFI).Based on Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) observations from June 1 to 16,2011,RFI over Europe was identified and analyzed using the modified principal component analysis algorithm in this paper.The X band AMSR-E measurements in England and Italy are mostly affected by the stable,persistent,active microwave transmitters on the surface,while the RFI source of other European countries is the interference of the reflected geostationary TV satellite downlink signals to the measurements of spaceborne microwave radiometers.The locations and intensities of the RFI induced by the geostationary TV and communication satellites changed with time within the observed period.The observations of spacebome microwave radiometers in ascending portions of orbits are usually interfered with over European land,while no RFI was detected in descending passes.The RFI locations and intensities from the reflection of downlink radiation are highly dependent upon the relative geometry between the geostationary satellite and the measuring passive sensor.Only these fields of view of a spacebome instrument whose scan azimuths are close to the azimuth relative to the geostationary satellite are likely to be affected by RFI.

  6. Improvement of a cryogenic radiometer for XFEL absolute intensity measurement

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T., E-mail: takahiro-tanaka@aist.go.jp [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba 305-8568 (Japan); Kato, M.; Kurosawa, T.; Morishita, Y.; Saito, N. [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba 305-8568 (Japan); Yabashi, M.; Tono, K.; Kudo, T.; Ishikawa, T. [SPring-8/RIKEN, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Shiraiwa, S. [Rockgate Co., 1-11-12 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2011-12-11

    A cryogenic radiometer was improved for measurements of the absolute radiant power of x-ray Free Electron Laser, which provides intense radiation with an ultra-short pulse duration. Based on simulation results obtained by the Monte Carlo program EGS 5 code, a new cavity absorber of the cryogenic radiometer was developed. The simulation results show that the new cavity absorber achieves absorptance close to unity for hard x-rays up to photon energies of 40 keV. The excellent performance of the new cavity absorber, as well as the consistency between the new and the former cavity, was confirmed by calibrating two different types of silicon photodiodes. The calibration results agreed well within their relative expanded uncertainties. To confirm the performance of the new cavity absorber in the high radiant power region, the radiant powers obtained with the cryogenic radiometer and an x-ray beam monitor were also compared. A strong correlation between the two detectors was obtained. With the new cavity absorber, the absolute radiant power of XFEL for photon energies of up to 40 keV with low uncertainties is expected to be measured.

  7. Advanced modelling of the Planck-LFI radiometers

    Energy Technology Data Exchange (ETDEWEB)

    Battaglia, P [Thales Alenia Space Italia S.p.A., S.S. Padana Superiore 290, 20090 Vimodrone (Italy); Franceschet, C; Bersanelli, M; Maino, D; Mennella, A [Universita di Milano, Dipartimento di Fisica, Via G. Celoria 16, I-20133 Milano (Italy); Zonca, A [INAF-IASF Milano, Via E. Bassini 15, I-20133 Milano (Italy); Butler, R C; Mandolesi, N [INAF-IASF Bologna, Via P. Gobetti, 101, I-40129 Bologna (Italy); D' Arcangelo, O; Platania, P [IFP-CNR, via Cozzi 53, 20125 Milano (Italy); Davis, R J [Jodrell Bank Centre for Astrophysics, Alan Turing Building, The University of Manchester, Manchester, M13 9PL (United Kingdom); Galeotta, S [INAF-OATs, Via G.B. Tiepolo 11, I-34131, Trieste (Italy); Guzzi, P [Numonyx, R and D Technology Center, Via C. Olivetti 2, 20041 Agrate Brianza (Italy); Hoyland, R [Instituto de AstrofIsica de Canarias, C/ Via Lactea S/N, E-38200, La Laguna (Tenerife) (Spain); Hughes, N; Jukkala, P [DA-Design Oy Jokioinen (Finland); Kettle, D [School of Electrical and Electronic Engineering, University of Manchester, Manchester, M60 1QD (United Kingdom); Laaninen, M [Ylinen Electronics Oy Kauniainen (Finland); Leonardi, R; Meinhold, P, E-mail: paola.battaglia@thalesaleniaspace.co [Department of Physics, University of California, Santa Barbara, CA 93106-9530 (United States)

    2009-12-15

    The Low Frequency Instrument (LFI) is a radiometer array covering the 30-70 GHz spectral range on-board the ESA Planck satellite, launched on May 14th, 2009 to observe the cosmic microwave background (CMB) with unprecedented precision. In this paper we describe the development and validation of a software model of the LFI pseudo-correlation receivers which enables to reproduce and predict all the main system parameters of interest as measured at each of the 44 LFI detectors. These include system total gain, noise temperature, band-pass response, non-linear response. The LFI Advanced RF Model (LARFM) has been constructed by using commercial software tools and data of each radiometer component as measured at single unit level. The LARFM has been successfully used to reproduce the LFI behavior observed during the LFI ground-test campaign. The model is an essential element in the database of LFI data processing center and will be available for any detailed study of radiometer behaviour during the survey.

  8. Microwave radiometer observations of soil moisture in HAPEX-SAHEL

    Science.gov (United States)

    Schmugge, Thomas J.; Chanzy, Andre; Kerr, Yann H.; van Oevelen, Peter

    1995-01-01

    Water stored in the soil serves as the reservoir for the evapotranspiration process, thus the interest in trying to map its spatial and temporal variations in experiments studying the soil- plant-atmosphere interactions at the GCM grid scale. During the 8 week intensive observation period (IOP) of HAPEX-Sahel (Hydrologic Atmospheric Pilot Experiment in the Sahel), this was done with two airborne microwave radiometer systems. The five frequency (5 to 90 GHz) PORTOS radiometer on the French ARAT aircraft and the single frequency (1.42 GHz) multibeam pushbroom microwave radiometer (PBMR) on the NASA C-130 were used. These aircraft measurements were supported by ground based observations at the central sites and, because of several rains during the IOP, covered a good range of soil wetness conditions that existed. The PBMR and the 5.05 GHz PORTOS channel in H polarization show a large dynamic range of TB on each day and between different days in response to variations in rainfall and drying conditions ranging from low TBs of 210 to 220 K for the wettest conditions to values of 280 to 290 K for the driest.

  9. Radiometer system to map the cosmic background radiation

    Science.gov (United States)

    Gorenstein, M. V.; Muller, R. A.; Smoot, G. F.; Tyson, J. A.

    1978-01-01

    A 33-GHz airborne radiometer system has been developed to map large angular scale variations in the temperature of the 3 K cosmic background radiation. A ferrite circulator switches a room-temperature mixer between two antennas pointing 60 deg apart in the sky. In 40 min of observing, the radiometer can measure the anisotropy of the microwave background with an accuracy of plus or minus 1 mK rms, or about 1 part in 3000 of 3 K. The apparatus is flown in a U-2 jet to 20 km altitude where 33-GHz thermal microwave emission from the atmosphere is at a low level. A second radiometer, tuned to 54 GHz near oxygen emission lines, monitors spurious signals from residual atmospheric radiation. The antennas, which have an extremely low side-lobe response of less than -65 dB past 60 deg, reject anisotropic radiation from the earth's surface. Periodic interchange of the antenna positions and reversal of the aircraft's flight direction cancel equipment-based imbalances. The system has been operated successfully in U-2 aircraft flown from NASA-Ames at Moffett Field, Calif.

  10. Source analysis of spaceborne microwave radiometer interference over land

    Science.gov (United States)

    Guan, Li; Zhang, Sibo

    2016-03-01

    Satellite microwave thermal emissions mixed with signals from active sensors are referred to as radiofrequency interference (RFI). Based on Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) observations from June 1 to 16, 2011, RFI over Europe was identified and analyzed using the modified principal component analysis algorithm in this paper. The X band AMSR-E measurements in England and Italy are mostly affected by the stable, persistent, active microwave transmitters on the surface, while the RFI source of other European countries is the interference of the reflected geostationary TV satellite downlink signals to the measurements of spaceborne microwave radiometers. The locations and intensities of the RFI induced by the geostationary TV and communication satellites changed with time within the observed period. The observations of spaceborne microwave radiometers in ascending portions of orbits are usually interfered with over European land, while no RFI was detected in descending passes. The RFI locations and intensities from the reflection of downlink radiation are highly dependent upon the relative geometry between the geostationary satellite and the measuring passive sensor. Only these fields of view of a spaceborne instrument whose scan azimuths are close to the azimuth relative to the geostationary satellite are likely to be affected by RFI.

  11. On Online Labeling with Polynomially Many Labels

    DEFF Research Database (Denmark)

    Babka, Martin; Bulánek, Jan; Cunat, Vladimír

    2012-01-01

    In the online labeling problem with parameters n and m we are presented with a sequence of nkeys from a totally ordered universe U and must assign each arriving key a label from the label set {1,2,…,m} so that the order of labels (strictly) respects the ordering on U. As new keys arrive it may be...

  12. Simple preparation of new [(18) F]F-labeled synthetic amino acid derivatives with two click reactions in one-pot and SPE purification.

    Science.gov (United States)

    Yook, Cheol-Min; Lee, Sang Ju; Oh, Seung Jun; Ha, Hyun-Joon; Lee, Jong Jin

    2015-06-30

    New [(18) F]fluorinated 1,2,3-triazolyl amino acid derivatives were efficiently prepared from Huisgen 1,3-dipolar cycloaddition reactions, well known as click reaction. We developed two simultaneous click reactions in one-pot with a simple solid-phase extraction (SPE) purification method. [(18) F]fluoro-1-propyne was obtained at a 45% non-decay corrected radiochemical yield based on the [(18) F]fluoride ion. The one-pot and simultaneous two click reactions were performed with unprotected azido-alkyl amino acid, [(18) F]fluoro-1-propyne, and lipophilic additive alkyne to produce three synthetic amino acid derivatives, AMC-101 ([(18) F]-6a), AMC-102 ([(18) F]-6b), and AMC-103 ([(18) F]-6c) with 29%, 28%, and 24% of non-decay corrected radiochemical yields, respectively. All radiotracers indicated that radiochemical purities were >95% without any residual organic solvent. Our new method involving two click reactions in one-pot showed high radiochemical and chemical purity by easy removal of the residual precursor from the simultaneous two click reactions. Copyright © 2015 John Wiley & Sons, Ltd.

  13. The multi-filter rotating shadowband radiometer (MFRSR) - precision infrared radiometer (PIR) platform in Fairbanks: Scientific objectives

    Energy Technology Data Exchange (ETDEWEB)

    Stamnes, K.; Leontieva, E. [Univ. of Alaska, Fairbanks (United States)

    1996-04-01

    The multi-filter rotating shadowband radiometer (MFRSR) and precision infrared radiometer (PIR) have been employed at the Geophysical Institute in Fairbanks to check their performance under arctic conditions. Drawing on the experience of the previous measurements in the Arctic, the PIR was equipped with a ventilator to prevent frost and moisture build-up. We adopted the Solar Infrared Observing Sytem (SIROS) concept from the Southern Great Plains Cloud and Radiation Testbed (CART) to allow implementation of the same data processing software for a set of radiation and meteorological instruments. To validate the level of performance of the whole SIROS prior to its incorporation into the North Slope of Alaska (NSA) Cloud and Radiation Testbed Site instrumental suite for flux radiatin measurements, the comparison between measurements and model predictions will be undertaken to assess the MFRSR-PIR Arctic data quality.

  14. 牛病毒性腹泻病毒荧光标记单克隆抗体的制备及鉴定%Preparation and identification of fluorescein-labelled monoclonal antibodies against bovine viral diarrhea virus

    Institute of Scientific and Technical Information of China (English)

    徐树兰; 李少英; 赵俊; 武华

    2011-01-01

    To obtain fluorescein-labelled monoclonal antibodies against different genotypes of bovine viral diarrhea virus(BVDV),specific monoclonal antibodies(McAbs) against BVDV type Ⅰ(BVDV-Ⅰ),type Ⅱ(BVDV-Ⅱ) or both were prepared.And in order to obtain large amount of the McAbs for fluorescein-labelling,BALB/c mice were intraperitoneally injected with hybridomas BV1,BV2,or BV12,respectively.Ascites for the three McAbs were purified with caprylic acid-ammonium method,and then identified by immunocompetence,protein concentration,and purity test.The purified McAbs were conjugated with fluorescein isothiocyanate(FITC) by stirring method.The F/P values of the three labeled McAbs were between 2.0 and 4.0,and their DFA titers to the respective BVDV strains were≥1∶200.Result of antigen cross reaction showed fine specificity of labeled-antibodies to their respective types of BVDV.In BVDV titration TCID50 test,fluorescent assay using the labeled McAbs can detect 1 TCID50 unit of BVDV virion.Preliminary diagnostic test to clinical samples showed that the fluorescence antibodies detected ≥95% of the positive samples,with a 100% concordance rate between the self-made and the imported fluorescence antibodies.Therefore,the three fluorescence antibodies established in the present study will be very useful for the identification of BVDV genotype,detection of NCP-BVDV and differential diagnosis of BVDV and CSFV,and worthy to be researched and developed in future.%为制备可以区分牛病毒性腹泻病毒(BVDV)基因型的荧光标记单克隆抗体,分别利用分泌抗牛病毒性腹泻Ⅰ型病毒(BVDV-Ⅰ)、牛病毒性腹泻Ⅱ型病毒(BVDV-Ⅱ)、牛病毒性腹泻病毒(BVDV-Ⅰ和BVDV-Ⅱ)单克隆抗体的杂交瘤细胞株BV1、BV2、BV12,腹腔接种BALB/c小鼠,大量制备单克隆抗体,用辛酸-硫酸铵法提纯,经活性、浓度、纯度检测合格后,利用搅拌法与异硫氰酸荧光素(FITC)偶联,制备成3

  15. Synthesis of deuterium labeled plant ethylene precursor

    Energy Technology Data Exchange (ETDEWEB)

    Nam, K.C. [Chonnam National Univ., Kwangju (Korea, Republic of). Dept. of Chemistry; Rapoport, H. [California Univ., Berkeley, CA (United States). Dept. of Chemistry

    1995-12-31

    Synthetic methods for the preparation of {beta}-deuterium labeled 2-keto-4-methylbutyric acid were investigated. Vinyl chloride was first reacted with the ethyl oxalyl chloride moiety using aluminum chloride as condensing agent and the addition of methyl mercaptan followed. Deuterium labeling was achieved by using NaBD{sub 4} reduction in pyridine. (author).

  16. A Microwave Radiometer for Internal Body Temperature Measurement

    Science.gov (United States)

    Scheeler, Robert Patterson

    This thesis presents the analysis and design of a microwave radiometer for internal body temperature measurements. There is currently no available method for non-invasive temperature measurement inside the human body. However, knowledge of both relative and absolute temperature variations over time is important to a number of medical applications. The research presented in this thesis details a proof-of-concept near-field microwave radiometer demonstrating relative thermometry of a multi-layer phantom. There are a number of technical challenges addressed in this thesis for radiometric determination of sub-degree temperature variations in the human body. A theoretical approach is developed for determining sensing depth from known complex layered tissues, which is defined as a figure of merit, and is shown to be dependent on frequency, electrical properties of the tissues, and the near-field probe. In order to obtain depth resolution, multiple frequency operation can be used, so multi-frequency probes are designed and demonstrated in this work. The choice of frequencies is determined not only by the tissue material properties, but also by the ever increasing radio interference in the environment. In this work, quiet bands allocated to radio astronomy are investigated. The radiometer and probe need to be compact to be wearable, and several advancements are made towards a fully wearable device: multi-frequency low-profile probes are designed and fabricated on a flexible substrate and the process of on-chip integration is demonstrated by a GaAs MMIC cold noise source for radiometer calibration. The implemented proof-of-concept device consists of two radiometers at 1.4 GHz and 2.7 GHz, designed with commercial inexpensive devices that can enable sufficient sensitivity. The device is tested on a phantom with two water layers whose temperatures are varied in a controlled manner, and focused on the human body temperature range. Measured results are discussed qualitatively

  17. Synthesis of exemestane labelled with (13)C.

    Science.gov (United States)

    Fontana, Erminia; Pignatti, Alberto; Giribone, Danilo; Di Salle, Enrico

    2008-08-01

    The synthesis of exemestane Aromasin, an irreversible steroidal aromatase inhibitor, specifically labelled with (13)C is reported. The preparation of [(13)C(3)]exemestane was achieved according to an eight-step procedure starting from the commercially available testosterone.

  18. Upgraded ECE radiometer on the Tore Supra Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Segui, J.L.; Molina, D.; Goniche, M.; Maget, P.; Udintsev, V.S. [Association Euratom-CEA, Centre d' Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Antar, G.Y. [Center for Energy Research, UCSD, La Jolla CA (United States); Kraemer-Flecken, A. [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Plasmaphysik

    2004-07-01

    An upgraded 32-channel heterodyne radiometer, 1 GHz spaced, is used on the Tore-Supra tokamak to measure the electron cyclotron emission (ECE) in the frequency range 78-110 GHz for the ordinary mode (O1) and 94-126.5 GHz for the extraordinary mode (X2). From now radial resolution is essentially limited by ECE relativistic effects related to electron temperature and density, not by the channels frequency spacing. For example, this leads to precise electron temperature mapping during magneto hydrodynamic activities (MHD). In the equatorial plane, we use a dual polarisation Gaussian optics lens antenna. It has low spreading and a perpendicular line-of-sight that gives ECE measurements very low refraction and Doppler effects. Assuming that the plasma is a black body and there is no overlap between ECE harmonics, one can deduce the electron temperature profile by using the first harmonic ordinary mode (O1) or the second harmonic extraordinary mode (X2). The principle radio frequency emitter (RF) has its frequencies down shifted into intermediary frequencies (IF) that span from 2 to 18 GHz in the single side band mode (SSB). It is amplified by low noise IF amplifiers before forming channels. A separate O/X mode RF front-end allows the use of an IF electronic mode selector. This gives the potentiality of simultaneous O/X mode measurements in the 94-110 GHz. RF and IF filters reject the gyrotron frequency (118 GHz) in order to perform electron temperature measurements during electron cyclotron resonance heated plasmas. A precise absolute spectral calibration is performed outside the tokamak vacuum vessel by using a 600 deg C black body hot source, a double coherent digital signal averaging (trigger, turn and clock) on the waveform generated by a mechanical chopper, and a simulated tokamak window. The use of differential electronics and strong electromagnetic shielding improves also the calibration precision. The fast and slow data acquisition systems are free of aliasing

  19. Preparation and HRP Labeling of Rabbit Polyclonal Antibodies against Seventeen Mammals%十七种哺乳动物二级抗体的制备和辣根过氧化物酶标记

    Institute of Scientific and Technical Information of China (English)

    林树柱; 刘先菊; 杨帆; 张连峰

    2011-01-01

    目的 制备兔抗17种哺乳动物的二级抗体,并进行辣根过氧化物酶标记,为哺乳血清学检测系统的建立提供工具.方法 利用饱和硫酸铵沉淀法粗纯抗体后,再利用protein A或protein G亲和层析的方法进一步纯化哺乳动物的IgG,免疫大耳白兔制备抗血清,利用免疫双扩散来检测抗血清的效价,并用Protein A亲和层析的方法来纯化兔抗哺乳动物的二级抗体,采用简易过碘酸钠法对纯化的兔抗哺乳动物的二级抗体进行辣根过氧化物酶标记,通过ELlSA方法测定标记抗体的效价,并利用Western blot方法考察标记抗体的特异性.结果 纯化了恒河猴、东北虎、布氏田鼠、黑线姬鼠、斑羚、原驼、果子狸、食蟹猴、梅花鹿、长爪沙鼠、马鹿、骆驼、大仓鼠、豚鹿、熊猴、大耳羊和雪貂等17种哺乳动物的血清IgG,分别免疫大耳白兔制备了这17种哺乳动物的兔抗血清,免疫双扩散法测定兔抗这17种哺乳动物的抗血清效价均达到1:32,并对纯化的兔抗恒河猴IgG、兔抗东北虎IgG、兔抗布氏田鼠IgG、兔抗黑线姬鼠IgG、兔抗斑羚IgG、兔抗原驼IgG、兔抗果子狸IgG、兔抗食蟹猴IgG、兔抗梅花鹿IgG、兔抗长爪沙鼠IgG、兔抗马鹿IgG、兔抗骆驼IgG、兔抗大仓鼠IgG、兔抗豚鹿IgG、兔抗熊猴IgG、兔抗大耳羊IgG和兔抗雪貂IgG等17种哺乳动物的二级抗体进行了辣根过氧化物酶标记,ELISA测定标记抗体的效价达到1:(2000~60000)左右,Western blots显示标记抗体具有很好的特异性.结论 成功制备了HRP标记的兔抗17种哺乳动物的二级抗体,为哺乳动物血清学检测体系的建立提供了工具.%Objective To prepare the rabbit polyclonal antibodies against seventeen mammals and to label the secondary antibodies with horseradish peroxidase for developing the serological test system of mammals. Methods IgGs of mammals were purified by precipitation with ammonium sulfate

  20. S193 radiometer brightness temperature precision/accuracy for SL2 and SL3

    Science.gov (United States)

    Pounds, D. J.; Krishen, K.

    1975-01-01

    The precision and accuracy with which the S193 radiometer measured the brightness temperature of ground scenes is investigated. Estimates were derived from data collected during Skylab missions. Homogeneous ground sites were selected and S193 radiometer brightness temperature data analyzed. The precision was expressed as the standard deviation of the radiometer acquired brightness temperature. Precision was determined to be 2.40 K or better depending on mode and target temperature.

  1. Synthesis of tritium labelled 24-epibrassinolide

    Energy Technology Data Exchange (ETDEWEB)

    Kolbe, A.; Marquardt, V.; Adam, G. (Inst. of Plant Biochemistry Halle, Halle/Saale (Germany))

    1992-10-01

    Deuterium and tritium 5,7,7-tris-labelled 24-epibrassinolide were prepared by base catalyzed exchange reaction using 24-epicastasterone tetraacetate 1 or bis-isopropylidenedioxy-24-epicastasterone 8 and labelled water. Baeyer-Villiger oxidation of the obtained labelled 6-ketones 2 and 3 with CF[sub 3]CO[sub 3]H gave after alkaline deacetylation of the resulting 4 and 5 the desired tris-labelled 24-epibrassinolides 6 and 7, respectively, or starting from 9 under simultaneous oxidation and deprotection in one step the same final products. (author).

  2. Boreal Inundation Mapping with SMAP Radiometer Data for Methane Studies

    Science.gov (United States)

    Kim, Seungbum; Brisco, Brian; Poncos, Valentin

    2017-04-01

    Inundation and consequent anoxic condition induce methane release, which is one of the most potent greenhouse gases. Boreal regions contain large amounts of organic carbon, which is a potentially major methane emission source under climatic warming conditions. Boreal wetlands in particular are one of the largest sources of uncertainties in global methane budget. Wetland spatial extent together with the gas release rate remains highly unknown. Characterization of the existing inundation database is poor, because of the inundation under clouds and dense vegetation. In this work, the inundation extent is derived using brightness temperature data acquired by the L-band Soil Moisture Active Passive (SMAP) satellite, which offers the L-band capabilities to penetrate clouds and vegetation at 3-day revisit. The fidelity of the SMAP watermask is assessed as a first step in this investigation by comparing with the following data sets: 3-m resolution maps derived using Radarsat synthetic aperture radar (SAR) data in northern Canada and multi-sensor climatology over Siberia. Because Radarsat coverages are limited despite its high spatial resolution, at the time and location where Radarsats are not available, we also compare with 3-km resolution SMAP SAR data that are concurrent with the SMAP radiometer data globally until July 2015. Inundation extents were derived with Radarsat, SMAP SAR, and SMAP radiometer over the 60 km x 60km area at Peace Athabasca Delta (PAD), Canada on 6 days in spring and summer 2015. The SMAP SAR results match the locations of Radarsat waterbodies. However, the SMAP SAR underestimates the water extent, mainly over mixed pixels that have subpixel land presence. The threshold value (-3 dB) applied to the SMAP SAR was determined previously over the global domain. The threshold is dependent on the type of local landcover within a mixed pixel. Further analysis is needed to locally optimize the threshold. The SMAP radiometer water fraction over Peace

  3. A spin label study of perturbation effects of N-(1-methyldodecyl)-N, N, N-trimethylammonium bromide and N-(1-methyldodecyl)-N, N-dimethylamine oxide on model membranes prepared from Escherichia coli-isolated lipids.

    Science.gov (United States)

    Sersen, F; Leitmanová, A; Devínsky, F; Lacko, I; Balgavý, P

    1989-04-01

    Interaction of bactericidal surfactants N-(1-methyldodecyl)-N, N, N-trimethylammonium bromide (2-ATDBr) and N-(1-methyldodecyl)-N, N-dimethylamine oxide (2-ATDNO) with phospholipid membranes prepared from Escherichia coli -- isolated lipids was studied by ESR spectroscopy using m-doxyl stearic acid (m-DSA, m = 5, 12, 16) and N-cetyl-N, N-dimethyl-N-tempoylammonium bromide spin labels located in different membrane depths. 2-ATDBr was found to be a more potent membrane perturbant than 2-ATDNO both at equal membrane and sample concentrations; this is in compliance with the respective antimicrobial activities of these agents. Using the statistical model of hydrocarbon chains in lipid bilayers, the probabilities of the formation of gauche conformations and the effective energy differences between the trans and gauche conformations were calculated from m-DSA order parameters for two different bilayer regions. Based on these parameters, a molecular model of the location of surfactant molecules in bilayer has been formulated. It has been suggested that at low concentrations the surfactant molecules are located in structural defects between lipid clusters in the bilayer. After filling up these defects, the surfactant molecules penetrate into the clusters between lipid molecules, expand the bilayer laterally and increase the amount of gauche conformations in the hydrocarbon chains in the hydrophobic core of the bilayer.

  4. An integrating sphere radiometer as a solution for high power calibrations in fibre optics

    Science.gov (United States)

    Carrasco-Sanz, Ana; Rodríguez-Barrios, Félix; Corredera, Pedro; Martín-López, Sonia; González-Herráez, Miguel; Hernanz, María Luisa

    2006-04-01

    This paper describes the design, characterization and calibration of a high power transfer standard for optical power measurements in optical fibres based on an integrating sphere radiometer. This radiometer, based on two detectors (Si and InGaAs), can measure powers between 100 nW and 10 W within the wavelength range of (400-1700) nm. The radiometer has been calibrated over the total spectral range of use against an electrically calibrated pyroelectric radiometer and different fibre laser diodes and ion lasers. The total uncertainty obtained is lower than ±1.5% for these wavelengths and power ranges (excluding the water absorption region).

  5. Radiometer Calibration and Characterization (RCC) User's Manual: Windows Version 4.0

    Energy Technology Data Exchange (ETDEWEB)

    Andreas, Afshin M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wilcox, Stephen M. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-29

    The Radiometer Calibration and Characterization (RCC) software is a data acquisition and data archival system for performing Broadband Outdoor Radiometer Calibrations (BORCAL). RCC provides a unique method of calibrating broadband atmospheric longwave and solar shortwave radiometers using techniques that reduce measurement uncertainty and better characterize a radiometer's response profile. The RCC software automatically monitors and controls many of the components that contribute to uncertainty in an instrument's responsivity. This is a user's manual and guide to the RCC software.

  6. Comparison of Profiling Microwave Radiometer, Aircraft, and Radiosonde Measurements From the Alliance Icing Research Study (AIRS)

    Science.gov (United States)

    Reehorst, Andrew L.

    2001-01-01

    Measurements from a profiling microwave radiometer are compared to measurements from a research aircraft and radiosondes. Data compared is temperature, water vapor, and liquid water profiles. Data was gathered at the Alliance Icing Research Study (AIRS) at Mirabel Airport outside Montreal, Canada during December 1999 and January 2000. All radiometer measurements were found to lose accuracy when the radome was wet. When the radome was not wetted, the radiometer was seen to indicate an inverted distribution of liquid water within a cloud. When the radiometer measurements were made at 15 deg. instead of the standard zenith, the measurements were less accurate.

  7. Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

    Science.gov (United States)

    McLinden, Matthew; Piepmeier, Jeffrey

    2013-01-01

    The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This

  8. Compositional Ground Truth of Diviner Lunar Radiometer Observations

    Science.gov (United States)

    Greenhagen, B. T.; Thomas, I. R.; Bowles, N. E.; Allen, C. C.; Donaldson Hanna, K. L.; Foote, E. J.; Paige, D. A.

    2012-01-01

    The Moon affords us a unique opportunity to "ground truth" thermal infrared (i.e. 3 to 25 micron) observations of an airless body. The Moon is the most accessable member of the most abundant class of solar system bodies, which includes Mercury, astroids, and icy satellites. The Apollo samples returned from the Moon are the only extraterrestrial samples with known spatial context. And the Diviner Lunar Radiometer (Diviner) is the first instrument to globally map the spectral thermal emission of an airless body. Here we compare Diviner observations of Apollo sites to compositional and spectral measurements of Apollo lunar soil samples in simulated lunar environment (SLE).

  9. The airborne EMIRAD L-band radiometer system

    DEFF Research Database (Denmark)

    Søbjærg, Sten Schmidl; Kristensen, Steen Savstrup; Balling, Jan E.;

    2013-01-01

    This paper describes the EMIRAD L-band radiometer, developed in support of the ESA/SMOS mission. The instrument is a fully polarimetric, dual antenna system, built with special focus on antenna accuracy, receiver stability, and detection and mitigation of radio frequency interference (RFI......). The EMIRAD system has been installed on three different airborne platforms for measurements of sea surface signatures and salinity, soil moisture, and the homogeneity of the Antarctic SMOS calibration site. The installations are shown in the paper, and some major results for ocean and ice observations...

  10. Cryogenic environment and performance for testing the Planck radiometers

    CERN Document Server

    Terenzi, L; Laaninen, M; Battaglia, P; Cavaliere, F; De Rosa, A; Hughes, N; Jukkala, P; Kilpiä, V -H; Morgante, G; Tomasi, M; Varis, J; Bersanelli, M; Butler, R C; Ferrari, F; Franceschet, C; Leutenegger, P; Mandolesi, N; Mennella, A; Silvestri, R; Stringhetti, L; Tuovinen, J; Valenziano, L; Villa, F; 10.1088/1748-0221/4/12/T12015

    2010-01-01

    This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.

  11. The preparation of nucleotides uniformly labelled with carbon-14 by biosynthetic methods. Isolation of adenylic, uridylic, cytidylic,and guanylic acids, from the alkaline hydrolysate of escherichia coli RNA; Preparacion de nucleiotidos uniformemente marcados con 14{sup C}, por via biosintetica. Aislamiento de los acidos adenilico, uridilico, citidilico y guanilico, procedentes de la hidrolisis alcalina de RNA de escherichia Coli.

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Pineda, M. D.; Pacheco Lopez, J.

    1978-07-01

    A method is described for the preparation and analysis of adenylic, uri dilic, cytidi- 11c and guanylic acids, labelled with 14{sup C}. Escherichia coli cells have been labelled by growing them in a medi dia containing glucose-14{sup C} as their only source of carbon. RNA is isolated from the cells, and after hydrolysis of the molecule the resulting nucleotides are separated by gel filtration and exchange chromatography. Chemical and radiochemical purity of the Isolated nucleotides is determined, and also its specific radioactivity. (Author) 30 refs.

  12. Food Label and You

    Medline Plus

    Full Text Available ... Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Food Home Food Ingredients, Packaging & Labeling Labeling & Nutrition The Food Label and You — Video Share Tweet Linkedin Pin ...

  13. Preparation of fluorescent carbon nanoparticles and application in the cell labeling*%荧光碳纳米粒子的制备及其在细胞标记中的应用

    Institute of Scientific and Technical Information of China (English)

    韩文英; 常云珍; 高飞

    2011-01-01

    In biological and medical fields, one of the important content in biomedical analysis is to stain,modify, labell and detect cells and biomolecules. In recent years, combining nano-materials and bio-detection technology makes an important development of the detection of biological molecules. In this work multicolor fluorescent carbon nanoparticles(CNPs) were prepared from the combustion soot of candles by refluxing in a mixed oxidants(30%H2O2/AcOH in V: V=2:1 ).Hela cells were labeled with varied concentrations of solutions of fluorescent CNPs and observed by the eonfocal laser scanning fluorescence microscope. Experimental results have shown that the fluorescent CNPS are excellent biomarkers for Hela cells. Owing to their advantages such as non-toxic,chemical inertness, biocompatibility, multi-colored marking, high luminous intensity and photochemical stability,fluorescent CNPs are hopefully qualified to be biomarker-candidates which are important in the application in biological and medical fields.%在生物医学领域,对细胞、生物分子进行染色、修饰标记和检测一直是生物医学分析的重要内容.近年来,纳米材料与生物检测技术的结合,使得生物分子的检测有了重要的发展.用30%H2O2/ACOH(V∶V=2∶1)混合氧化性酸溶液回流蜡烛烟炱制备得到荧光碳纳米粒子,用不同浓度的荧光碳纳米粒子对Hela细胞进行荧光标记,在激光共聚焦荧光显微镜下观察得到荧光标记图像.结果表明,荧光碳纳米粒子能够有效地对Hela细胞进行荧光标记.荧光碳纳米粒子具有无毒、化学惰性和良好的生物相容性,可进行多色标记,并且发光强度高,光化学稳定性好,在生物医药领域具有重要的应用价值.

  14. Comparative Analysis of Radiometer Systems Using Non-Stationary Processes

    Science.gov (United States)

    Racette, Paul; Lang, Roger; Krebs, Carolyn A. (Technical Monitor)

    2002-01-01

    Radiometers require periodic calibration to correct for instabilities in the receiver response. Various calibration techniques exist that minimize the effect of instabilities in the receivers. The optimal technique depends upon many parameters. Some parameters are constrained by the particular application and others can be chosen in the system design. For example, the measurement uncertainty may be reduced to the limits of the resolution of the measurement (sensitivity) if periodic absolute calibration can be performed with sufficient frequency. However if the period between calibrations is long, a reference-differencing technique, i.e. Dicke-type design, can yield better performance. The measurement uncertainty not only depends upon the detection scheme but also on the number of pixels between calibrations, the integration time per pixel, integration time per calibration reference measurement, calibration reference temperature, and the brightness temperature of what is being measured. The best scheme for reducing the measurement uncertainty also depends, in large part, on the stability of the receiver electronics. In this presentation a framework for evaluating calibration schemes for a wide range of system architectures is presented. Two methods for treating receiver non-stationarity are compared with radiometer measurements.

  15. ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK

    Energy Technology Data Exchange (ETDEWEB)

    AUSTIN, ME; LOHR, J

    2002-08-01

    OAK A271 ECE RADIOMETER UPGRADE ON THE DIII-D TOKAMAK. The electron cyclotron emission (ECE) heterodyne radiometer diagnostic on DIII-D has been upgraded with the addition of eight channels for a total of 40. The new, higher frequency channels allow measurements of electron temperature into the magnetic axis in discharges at maximum field, 2.15 T. The complete set now extends over the full usable range of second harmonic emission frequencies at 2.0 T covering radii from the outer edge inward to the location of third harmonic overlap on the high field side. Full coverage permits the measurement of heat pulses and magnetohydrodynamic (MHD) fluctuations on both sides of the magnetic axis. In addition, the symmetric measurements are used to fix the location of the magnetic axis in tokamak magnetic equilibrium reconstructions. Also, the new higher frequency channels have been used to determine central T{sub e} with good time resolution in low field, high density discharges using third harmonic ECE in the optically gray and optically thick regimes.

  16. First national intercomparison of solar ultraviolet radiometers in Italy

    Science.gov (United States)

    Diémoz, H.; Siani, A. M.; Casale, G. R.; di Sarra, A.; Serpillo, B.; Petkov, B.; Scaglione, S.; Bonino, A.; Facta, S.; Fedele, F.; Grifoni, D.; Verdi, L.; Zipoli, G.

    2011-08-01

    A blind intercomparison of ground-based ultraviolet (UV) instruments has been organized for the first time in Italy. The campaign was coordinated by the Environmental Protection Agency of Aosta Valley (ARPA Valle d'Aosta) and took place in Saint-Christophe (45.8° N, 7.4° E, 570 m a.s.l.), in the Alpine region, from 8 to 23 June 2010. It involved 8 institutions, 10 broadband radiometers, 2 filter radiometers and 2 spectroradiometers. Synchronized measurements of downward global solar UV irradiance at the ground were collected and the raw series were then individually processed by the respective operators on the base of their own procedures and calibration data. A radiative transfer model was successfully applied as an interpretative tool. The input parameters and output results are described in detail. The comparison was performed in terms of global solar UV Index and integrated UV-A irradiance against a well-calibrated double monochromator spectroradiometer as reference. An improved algorithm for comparing broadband data and spectra has been developed and is discussed in detail. For some instruments, we found average deviations ranging from -16 % up to 20 % relative to the reference and diurnal variations as large as 15 % even in clear days. Remarkable deviations were found for the instruments calibrated in the manufacturers' facilities and never involved in field intercomparison. Finally, some recommendations to the UV operators based on the campaign results are proposed.

  17. First national intercomparison of solar ultraviolet radiometers in Italy

    Directory of Open Access Journals (Sweden)

    H. Diémoz

    2011-05-01

    Full Text Available A blind intercomparison of ground-based ultraviolet (UV instruments has been organized for the first time in Italy. The campaign was coordinated by the Environmental Protection Agency of Aosta Valley (ARPA Valle d'Aosta and took place in Saint-Christophe (45.8° N, 7.4° E, 570 m a.s.l., in the Alpine region, from 8 to 23 June 2010. It involved 8 institutions, 10 broadband radiometers, 2 filter radiometers and 2 spectroradiometers. Synchronized measurements of downward global solar UV irradiance at the ground were collected and the raw series were then individually processed by the respective operators on the basis of their own procedures and calibration data. The comparison was performed in terms of global solar UV Index and integrated UV-A irradiance against a well-calibrated double monochromator spectroradiometer as reference. An improved algorithm for comparing broadband data and spectra has been developed. For some instruments, we found average deviations ranging from −16 % up to 20 % relative to the reference and diurnal variations as large as 15 % even in clear days. Remarkable deviations also arose from instruments recently in operation and never involved in field intercomparison.

  18. Direct Solar Irradiance measurements with a Cryogenic Solar Absolute Radiometer

    Science.gov (United States)

    Walter, Benjamin; Winkler, Rainer; Graber, Florian; Finsterle, Wolfgang; Fox, Nigel; Li, Vivian; Schmutz, Werner

    2017-02-01

    The World Radiometric Reference (WRR) is an artefact based reference for Direct Solar Irradiance (DSI) measurements. The WRR is realized by a group of electrical substitution radiometers, the World Standard Group (WSG). In recent years, a relative difference of about -0.3% between the International System of Units (SI) scale and the WRR scale was observed with the SI scale being lower. The Cryogenic Solar Absolute Radiometer (CSAR) aims for i) providing direct traceability of DSI measurements to the SI system, ii) reducing the overall uncertainty of DSI measurements towards 0.01% and for iii) replacing the WSG in future. The latest SI-WRR intercomparisons performed with CSAR revealed a relative difference of -0.29% ± 0.064% (k = 1) between the SI and the WRR scale, a result that agrees well with previous findings. The uncertainty of corrections for the window transmittance results currently in the largest contribution to the total uncertainty for the CSAR measurements. The formal transition from the WRR to the SI-scale for DSI measurements is currently being discussed in the WMO/CIMO Task Team on Radiation References.

  19. Spatial sampling errors for a satellite-borne scanning radiometer

    Science.gov (United States)

    Manalo, Natividad D.; Smith, G. L.

    1991-01-01

    The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer is planned as the Earth radiation budget instrument for the Earth Observation System, to be flown in the late 1990's. In order to minimize the spatial sampling errors of the measurements, it is necessary to select design parameters for the instrument such that the resulting point spread function will minimize spatial sampling errors. These errors are described as aliasing and blurring errors. Aliasing errors are due to presence in the measurements of spatial frequencies beyond the Nyquist frequency, and blurring errors are due to attenuation of frequencies below the Nyquist frequency. The design parameters include pixel shape and dimensions, sampling rate, scan period, and time constants of the measurements. For a satellite-borne scanning radiometer, the pixel footprint grows quickly at large nadir angles. The aliasing errors thus decrease with increasing scan angle, but the blurring errors grow quickly. The best design minimizes the sum of these two errors over a range of scan angles. Results of a parameter study are presented, showing effects of data rates, pixel dimensions, spacecraft altitude, and distance from the spacecraft track.

  20. First national intercomparison of solar ultraviolet radiometers in Italy

    Directory of Open Access Journals (Sweden)

    H. Diémoz

    2011-08-01

    Full Text Available A blind intercomparison of ground-based ultraviolet (UV instruments has been organized for the first time in Italy. The campaign was coordinated by the Environmental Protection Agency of Aosta Valley (ARPA Valle d'Aosta and took place in Saint-Christophe (45.8° N, 7.4° E, 570 m a.s.l., in the Alpine region, from 8 to 23 June 2010. It involved 8 institutions, 10 broadband radiometers, 2 filter radiometers and 2 spectroradiometers. Synchronized measurements of downward global solar UV irradiance at the ground were collected and the raw series were then individually processed by the respective operators on the base of their own procedures and calibration data. A radiative transfer model was successfully applied as an interpretative tool. The input parameters and output results are described in detail. The comparison was performed in terms of global solar UV Index and integrated UV-A irradiance against a well-calibrated double monochromator spectroradiometer as reference. An improved algorithm for comparing broadband data and spectra has been developed and is discussed in detail. For some instruments, we found average deviations ranging from −16 % up to 20 % relative to the reference and diurnal variations as large as 15 % even in clear days. Remarkable deviations were found for the instruments calibrated in the manufacturers' facilities and never involved in field intercomparison. Finally, some recommendations to the UV operators based on the campaign results are proposed.

  1. T2-prepared velocity selective labelling

    DEFF Research Database (Denmark)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra M A

    2016-01-01

    2-BIOS correlated with SO2-NIRS (R(2)=0.41, p=0.002) and SvO2-T2-TRIR (R(2)=0.87, p=0.002). In addition, SO2-NIRS correlated with SvO2-T2-TRIR (R(2)=0.85, p=0.003) Frontal cerebral blood flow correlated with SO2-T2-BIOS (R(2)=0.21, p=0.04), but was not significant in relation to SO2-NIRS. DISCUSSION...

  2. Deep Label Distribution Learning With Label Ambiguity

    Science.gov (United States)

    Gao, Bin-Bin; Xing, Chao; Xie, Chen-Wei; Wu, Jianxin; Geng, Xin

    2017-06-01

    Convolutional Neural Networks (ConvNets) have achieved excellent recognition performance in various visual recognition tasks. A large labeled training set is one of the most important factors for its success. However, it is difficult to collect sufficient training images with precise labels in some domains such as apparent age estimation, head pose estimation, multi-label classification and semantic segmentation. Fortunately, there is ambiguous information among labels, which makes these tasks different from traditional classification. Based on this observation, we convert the label of each image into a discrete label distribution, and learn the label distribution by minimizing a Kullback-Leibler divergence between the predicted and ground-truth label distributions using deep ConvNets. The proposed DLDL (Deep Label Distribution Learning) method effectively utilizes the label ambiguity in both feature learning and classifier learning, which help prevent the network from over-fitting even when the training set is small. Experimental results show that the proposed approach produces significantly better results than state-of-the-art methods for age estimation and head pose estimation. At the same time, it also improves recognition performance for multi-label classification and semantic segmentation tasks.

  3. Physical, biological, and chemical data from radiometer, profiling reflectance radiometer, and CTD casts in a world-wide distribution as part of the SeaWiFS/SIMBIOS project from 13 September 1981 to 16 December 1999 (NODC Accession 0000632)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Physical, biological, and chemical data were collected using radiometer, profiling reflectance radiometer, and CTD casts in a world-wide distribution from 13...

  4. Preparation of {sup 35}SO{sub 4}H{sub 2} and of some other {sup 35}S labeled mineral compounds; Preparation de {sup 35}SO{sub 4}H{sub 2} et de quelques autres composes mineraux simples marques a {sup 35}S

    Energy Technology Data Exchange (ETDEWEB)

    De la Gueronniere, E.; Henry, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Methods of preparation, from pile irradiated KCI, of the following labeled molecules are described: - carrier free H{sub 2}SO{sub 4} - SCd (100 m curies/milli mole) - solution of SNa{sub 2} (100 m curies/milli mole) - solution of SK{sub 2} (100 m curies/milli mole) - S metalloid (100 m curies/milli mole) - SO{sub 3}Na{sub 2} (90 m curies/milli mole) - S{sub 2}C{sub 3}Na{sub 2} (50 m curies/mammalia). (author) [French] On decrit les methodes de preparation, a partir de KCl irradie dans les piles, des molecules suivantes marquees au {sup 35}S: - SO{sub 4}H{sub 2} (sans entraineur) - SCd (100 mcuries/millimole) - solution de SNa{sub 2} (100 mcuries/millimole) - solution de SK{sub 2} (100 mcuries/millimole) - S metalloide (100 mcuries/millimole) - Na{sub 2}SO{sub 3} (90 mcuries/millimole) - Na{sub 2}S{sub 2}C{sub 3} (50 mcuries/milIimole). (auteur)

  5. A simple method to minimize orientation effects in a profiling radiometer

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; SrinivasaKumar, T.; Lotlikar, A.

    -fall radiometer is found to be a better option for measuring underwater light parameters as it avoids the effects of ship shadow and is easy to operate, the measurements demand profiling the radiometer vertical in water with minimum tilt. Here we present...

  6. Compact Front-end Prototype for Next Generation RFI-rejecting Polarimetric L-band Radiometer

    DEFF Research Database (Denmark)

    Jensen, Brian Sveistrup; Søbjærg, Sten Schmidl; Skou, Niels

    2009-01-01

    Realizing the need for lower noise figure and smaller physical size in todays higly sensitive radiometers, this paper presents a new compact analog front-end (AFE) for use with the existing L-band (1400-1427 MHz) radiometer designed and operated by the Technical University of Denmark. Using...

  7. 罗氏沼虾18S rRNA基因生物素标记探针的制备及应用%Preparation and application of the biotin-labeled probe of 18S rRNA gene in Macrobrachium rosenbergii

    Institute of Scientific and Technical Information of China (English)

    高风英; 叶星; 白俊杰; 吴锐全; 劳海华; 简清; 罗建仁

    2005-01-01

    Probes are essential for study of gene expression and regulation. In this study, a method was established to prepare the biotin-labeled probe for 18S rRNA gene of freshwater prawn, Macrobrachium rosenbergii. And the labeled method was used to produce a lysozyme gene probe, then applied in analysis of lysozyme gene expression. Primers were designed according to the nucleotide sequences of 18S rRNA of Decalxxta in order to isolate the 18S rRNA gene sequences of M. rosenbergii. Total genomic DNA was isolated from hepatopancreas of the freshwater prawn. A specific DNA fragment with desired size was amplified by PCR using the total DNA as templates. The DNA fragment was inserted into pGEM-T Easy vector and sequenced. The result of BLAST and alignment analysis confirmed that the DNA fragment isolated was the 18S rRNA gene of M. rosenbergii, which was 418 nt in length.Biotin-labeled probe of the 18S rRNA was then produced by PCR using the recombinant plasmid as templates. The biotin-21-dTTP and the non-labeled dNTP were added to the PCR reaction system. Ratio of the biotin-21-dTTP and the non-labeled dTFP was 3 to 1.The yield of the labeled probe is 300 ng·μL-1. The detection limit of the probe is 60 pg. A biotin-labeled probe of lysozyme gene was prepared by the same label method, and the yield of the lysozyme gene probe is 500 ng·μL-1. These biotin-labeled probes were applied in Northern dot blotting analysis of tissue distribution of lysoyzme mRNA of M. rosenbergii. Signals were scanned and quantified by Analysis System of Biology Image. The signal intensity ratio of the lysozyme to 18S rRNA represents the relative expression level of lysozyme mRNA. The results showed that the lysozyme mRNA existed in all the tissues checked, including eye,muscle, gill, hepatopancreas, haemocytes and intestine. But lysoyzme mRNA levels varied among different tissues. The highest level was found in the intestine, and the second was in the hepatopancreas and the lowest was in the

  8. The practicality of nanoceria-PAN-based (68)Ge/(68)Ga generator toward preparation of (68)Ga-labeled cyclic RGD dimer as a potential PET radiotracer for tumor imaging.

    Science.gov (United States)

    Chakraborty, Sudipta; Chakravarty, Rubel; Sarma, Haladhar D; Dash, Ashutosh; Pillai, M R A

    2013-02-01

    Cyclic RGD (Arg-Gly-Asp) peptides radiolabeled with (68)Ga have great potential for the early tumor detection and noninvasive monitoring of tumor metastasis and therapeutic response. Herein, the preparation of (68)Ga-labeled DOTA-E[c(RGDfK)](2) (DOTA=1,4,7,10-tetraazacylododecane-1,4,7,10-tetracetic acid; E=Glutamic acid; R=Arginine; G=Glycine; D=Aspartic acid; f=phenyl alanine; K=lysine) using (68)Ga directly eluted from a nanoceria-polyacrylonitrile (CeO(2)-PAN)-based (68)Ge/(68)Ga generator developed in-house was reported. The (68)Ga complex of DOTA-E[c(RGDfK)](2) was synthesized with >98% radiochemical purity by incubating 20 μg of the conjugate with (68)GaCl(3) (74-111 MBq) in acetate buffer (pH 3.5-4.0) at 90°C for 10 minutes. The complex exhibited excellent in vitro stability in 0.1 M EDTA solution at room temperature upto 1 hour studied (radiochemical purity: 98.0%). The biological efficacy of the radiolabeled conjugate was studied in C57/BL6 mice bearing melanoma tumors. The results of the biodistribution studies revealed significant tumor uptake (4.14±0.54%ID/g) within 10 minutes postinjection (p.i.), which increased further to 4.61±0.31%ID/g at 30 minutes p.i. The tumor-to-blood ratio was found to increase from 1.75±0.42 at 10 minutes p.i. to 2.25±0.20 at 60 minutes p.i., whereas the tumor-to-liver and tumor-to-muscle ratio between the same time points increased from 2.71±0.76 to 3.31±0.84 and 5.37±1.08 to 8.97±1.32, respectively. The study successfully demonstrated the preparation of (68)Ga-DOTA-E[c(RGDfK)](2) as a potential positron-emission tomography radiotracer for possible use in tumor imaging by using (68)Ga eluted from a reliable, easy-to-handle (68)Ge/(68)Ga generator developed in-house, without any postelution purification of (68)Ga.

  9. Intercomparison of 51 radiometers for determining global horizontal irradiance and direct normal irradiance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Wilcox, Stephen; Stoffel, Thomas

    2016-08-01

    Accurate solar radiation measurements require properly installed and maintained radiometers with calibrations traceable to the World Radiometric Reference. This study analyzes the performance of 51 commercially available and prototype radiometers used for measuring global horizontal irradiances or direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with an internal shading mask deployed at the National Renewable Energy Laboratory's (NREL) Solar Radiation Research Laboratory. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012), and their measurements were compared under clear-sky, partly cloudy, and mostly cloudy conditions to reference values of low estimated measurement uncertainties. The intent of this paper is to present a general overview of each radiometer's performance based on the instrumentation and environmental conditions available at NREL.

  10. Preparation of manganese salts of carboxylic acids labelled with ''54Mn and comparison with ''54 MnCl{sub 2} in liquid scintillation counting; Preparacion de sales manganosas de acidos alifaticos monocarboxilicos marcados con ''54 MnCl{sub 2} en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Arcos Merino, J. M. los; Grau Malonda, A.

    1992-07-01

    Procedures for liquid scintillation sample preparation of manganese dimethylbutirate, decanoate and palmitate, labelled with 54 Mn are described. their quenching effect, spectral evolution and counting stability along several weeks are analysed in liquid scintillation measurements with Toluene. HISafe II. PCS, instagel. Dioxane-naphtalene and Toluene-alcohol. For comparison, Inorganic 54 MnCl-2 samples are also studied, resulting in acceptable counting stability but showing greater quenching and signs of little spectral degradation against the organic samples. (Author)

  11. Estimating atmospheric temperature profile by an airborne microwave radiometer

    Science.gov (United States)

    Zhang, Jun; Xu, Jian; Kenntner, Mareike; Schreier, Franz; Doicu, Adrian

    2017-04-01

    As the rising atmospheric issues such as climate change, air pollution, and ozone depletion have extracted extensive attraction worldwide, observing and modeling of atmospheric quantities becomes critical to our understanding of the environment. This work focuses on the performance of an airborne passive microwave radiometer called MTP (Microwave Temperature Profiler). We aim to obtain vertically distributed atmospheric temperature from intensities measured by the instrument in terms of three frequencies and ten viewing angles. A retrieval program TIRAMISU (Temperature InveRsion Algorithm for MIcrowave SoUnding) has been utilized for processing the MTP data. To solve this severely ill-posed inverse problem, an analysis of different ways of constructing the penalty term onto the Tikhonov-type objective function is conducted. This numerical analysis can help us to better understand pros and cons of these regularization methods and to investigate the measurement capabilities of MTP.

  12. Water Vapour Radiometers for the Australia Telescope Compact Array

    CERN Document Server

    Indermuehle, Balthasar T; Crofts, Jonathan

    2012-01-01

    We have developed Water Vapour Radiometers (WVRs) for the Australia Telescope Compact Array (ATCA) that are capable of determining path fluctuations by virtue of measuring small temperature fluctuations in the atmosphere using the 22.2 GHz water vapour line for each of the six antennae. By measuring the line of sight variations of the water vapour, the induced path excess and thus the phase delay can be estimated and corrections can then be applied during data reduction. This reduces decorrelation of the source signal. We demonstrate how this recovers the telescope's efficiency and image quality as well as how this improves the telescope's ability to use longer baselines at higher frequencies, thereby resulting in higher spatial resolution. A description of the WVR hardware design, their calibration and water vapour retrieval mechanism is given.

  13. Deep-sea low-light radiometer system.

    Science.gov (United States)

    Haag, Justin M; Roberts, Paul L D; Papen, George C; Jaffe, Jules S; Li, Linhai; Stramski, Dariusz

    2014-12-01

    Two single-waveband low-light radiometers were developed to characterize properties of the underwater light field relevant to biological camouflage at mesopelagic ocean depths. Phenomena of interest were vertical changes in downward irradiance of ambient light at wavelengths near 470 nm and 560 nm, and flashes from bioluminescent organisms. Depth profiles were acquired at multiple deep stations in different geographic regions. Results indicate significant irradiance magnitudes at 560 nm, providing direct evidence of energy transfer as described by Raman scattering. Analysis of a night profile yielded multiple examples of bioluminescent flashes. The selection of high-sensitivity, high-speed silicon photomultipliers as detectors enabled measurement of spectrally-resolved irradiance to greater than 400 m depth.

  14. The Planck/LFI Radiometer Electronics Box Assembly

    CERN Document Server

    Herreros, J M; Rebolo, R; Chulani, H; Rubino-Martin, J A; Hildebrandt, S R; Bersanelli, M; Butler, R C; Miccolis, M; Pena, A; Pereira, M; Torrero, F; Franceschet, C; Lopez, M; Alcala, C; 10.1088/1748-0221/4/12/T12008

    2010-01-01

    The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art processors, communication interfaces and real time operating system software in order to meet the scientific performance of the LFI. We present a technical summary of the REBA, including a physical, functional, electrical, mechanical and thermal description. Aspects of the design and development, the assembly, the integration and the verification of the equipment are provided. A brief description of the LFI on board software is given including the Low-Level Software and the main functionalities and architecture of the Application Software. The compressor module, which has been developed as an independent product, later integrated in the application, is also described in this paper. Two identical engineering models EM and AVM, the engineering qualification model EQM, the flight model ...

  15. COBE Differential Microwave Radiometers - Instrument design and implementation

    Science.gov (United States)

    Smoot, G.; Bennett, Charles; Weber, R.; Maruschak, John; Ratliff, Roger; Janssen, M.

    1990-01-01

    Differential Microwave Radiometers (DMRs) at frequencies of 31.5, 53, and 90 GHz have been designed and built to map the large angular scale variations in the brightness temperature of the cosmic microwave background radiation. The instrument is being flown aboard NASA's Cosmic Background Explorer (COBE) satellite, launched on November 18, 1989. Each receiver input is switched between two antennas pointing 60 deg apart on the sky. The satellite is in near-polar orbit with the orbital plane precessing at 1 deg per day, causing the beams to scan the entire sky in 6 months. In 1 year of observation, the instruments are capable of mapping the sky to an rms sensitivity of 0.1 mK per 7 deg field of view. The mission and the instrument have been carefully designed to minimize the need for systematic corrections to the data.

  16. Modeling the frequency response of microwave radiometers with QUCS

    CERN Document Server

    Zonca, Andrea; Williams, Brian; Rubin, Ishai; D'Arcangelo, Ocleto; Meinhold, Peter; Lubin, Philip; Franceschet, Cristian; Yahn, Stefan; Mennella, Aniello; Bersanelli, Marco

    2010-01-01

    Characterization of the frequency response of coherent radiometric receivers is a key element in estimating the flux of astrophysical emissions, since the measured signal depends on the convolution of the source spectral emission with the instrument band shape. Laboratory Radio Frequency (RF) measurements of the instrument bandpass often require complex test setups and are subject to a number of systematic effects driven by thermal issues and impedance matching, particularly if cryogenic operation is involved. In this paper we present an approach to modeling radiometers bandpasses by integrating simulations and RF measurements of individual components. This method is based on QUCS (Quasi Universal Circuit Simulator), an open-source circuit simulator, which gives the flexibility of choosing among the available devices, implementing new analytical software models or using measured S-parameters. Therefore an independent estimate of the instrument bandpass is achieved using standard individual component measureme...

  17. Retrieving cloudy atmosphere parameters from RPG-HATPRO radiometer data

    Science.gov (United States)

    Kostsov, V. S.

    2015-03-01

    An algorithm for simultaneously determining both tropospheric temperature and humidity profiles and cloud liquid water content from ground-based measurements of microwave radiation is presented. A special feature of this algorithm is that it combines different types of measurements and different a priori information on the sought parameters. The features of its use in processing RPG-HATPRO radiometer data obtained in the course of atmospheric remote sensing experiments carried out by specialists from the Faculty of Physics of St. Petersburg State University are discussed. The results of a comparison of both temperature and humidity profiles obtained using a ground-based microwave remote sensing method with those obtained from radiosonde data are analyzed. It is shown that this combined algorithm is comparable (in accuracy) to the classical method of statistical regularization in determining temperature profiles; however, this algorithm demonstrates better accuracy (when compared to the method of statistical regularization) in determining humidity profiles.

  18. Calibrating ground-based microwave radiometers: Uncertainty and drifts

    Science.gov (United States)

    Küchler, N.; Turner, D. D.; Löhnert, U.; Crewell, S.

    2016-04-01

    The quality of microwave radiometer (MWR) calibrations, including both the absolute radiometric accuracy and the spectral consistency, determines the accuracy of geophysical retrievals. The Microwave Radiometer Calibration Experiment (MiRaCalE) was conducted to evaluate the performance of MWR calibration techniques, especially of the so-called Tipping Curve Calibrations (TCC) and Liquid Nitrogen Calibrations (LN2cal), by repeatedly calibrating a fourth-generation Humidity and Temperature Profiler (HATPRO-G4) that measures downwelling radiance between 20 GHz and 60 GHz. MiRaCalE revealed two major points to improve MWR calibrations: (i) the necessary repetition frequency for MWR calibration techniques to correct drifts, which ensures stable long-term measurements; and (ii) the spectral consistency of control measurements of a well known reference is useful to estimate calibration accuracy. Besides, we determined the accuracy of the HATPRO's liquid nitrogen-cooled blackbody's temperature. TCCs and LN2cals were found to agree within 0.5 K when observing the liquid nitrogen-cooled blackbody with a physical temperature of 77 K. This agreement of two different calibration techniques suggests that the brightness temperature of the LN2 cooled blackbody is accurate within at least 0.5 K, which is a significant reduction of the uncertainties that have been assumed to vary between 0.6 K and 1.5 K when calibrating the HATPRO-G4. The error propagation of both techniques was found to behave almost linearly, leading to maximum uncertainties of 0.7 K when observing a scene that is associated with a brightness temperature of 15 K.

  19. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-07-01

    Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

  20. Evaluation of Radiometers Deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Wilcox, S.; Stoffel, T.

    2014-02-01

    This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances and direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with fixed internal shading and are all deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. Data from 32 global horizontal irradiance and 19 direct normal irradiance radiometers are presented. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference global horizontal irradiances and direct normal irradiances.

  1. Evaluation of Radiometers Deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Wilcox, Stephen; Stoffel, Thomas

    2015-12-23

    This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances and direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with fixed internal shading and are all deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. Data from 32 global horizontal irradiance and 19 direct normal irradiance radiometers are presented. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference global horizontal irradiances and direct normal irradiances.

  2. Continuous Time Series of Water Vapor Profiles from a Combination of Raman Lidar and Microwave Radiometer

    Directory of Open Access Journals (Sweden)

    Foth Andreas

    2016-01-01

    Full Text Available In this paper, we present a method to retrieve continuous water vapor profiles from a combination of a Raman lidar and a microwave radiometer. The integrated water vapor from the microwave radiometer is used to calibrate the Raman lidar operationally resulting in small biases compared to radiosondes. The height limitations for Raman lidars (cloud base and daylight contamination can be well compensated by the application of a two–step algorithm combining the Raman lidars mass mixing ratio and the microwave radiometers brightness temperatures.

  3. Filter-radiometer-based realization of candela and establishment of photometric scale at UME

    Science.gov (United States)

    Samedov, Farhad; Durak, Murat; Bazkır, Özcan

    2005-11-01

    The luminous intensity unit of candela was realized based on filter-radiometer, which is traceable to detector-based primary standard electrical substitution cryogenic radiometer (ESCR). In that realization the traditional Osram Wi41/G-type incandescent lamp and filter-radiometer consisting of an aperture, a V(λ) filter and a silicon photodiode based trap detector were used as light source and detection element, respectively. Measurement techniques of effective aperture area, spectral transmittance of V(λ) filter and absolute responsivity of trap detector are also presented.

  4. Measurement of Ocean Wind Vector by an Airborne, Imaging Polarimetric Radiometer

    DEFF Research Database (Denmark)

    Skou, Niels; Laursen, Brian

    1998-01-01

    Airborne measurements of the sea surface have been carried out with an imaging polarimetric 16-GHz radiometer system, aimed at determining the wind direction. The radiometer system features a high-speed digital correlator, and it measures all four parameters of the brightness temperature Stokes...... vector simultaneously. Preliminary experiments have confirmed the directional signatures of the sea brightness temperature as reported by other researchers and have led to development of improved instrumentation with the intention of determining the wind vector pixel by pixel in the radiometer imagery....

  5. Improving the solar zenith angle dependence of broadband UV radiometers calibration

    Directory of Open Access Journals (Sweden)

    M. L. Cancillo

    2007-12-01

    Full Text Available This paper focusses on the proposal of a new method for the calibration of broadband ultraviolet radiometers. The advantage of the method proposed is the accurate modelling of the dependence on the solar zenith angle. The new model is compared with other one-step calibration methods and with the two-step method, which requires the knowledge of the actual response of the broadband radiometer. For this purpose, three broadband radiometers are calibrated against a spectrophotometer of reference. The new method is validated comparing its predictions with the spectrophotometer measurements using an independent data set.

  6. Aerosol Remote Sensing Applications for Airborne Multiangle, Multispectral Shortwave Radiometers

    Science.gov (United States)

    von Bismarck, Jonas; Ruhtz, Thomas; Starace, Marco; Hollstein, André; Preusker, René; Fischer, Jürgen

    2010-05-01

    Aerosol particles have an important impact on the surface net radiation budget by direct scattering and absorption (direct aerosol effect) of solar radiation, and also by influencing cloud formation processes (semi-direct and indirect aerosol effects). To study the former, a number of multispectral sky- and sunphotometers have been developed at the Institute for Space Sciences of the Free University of Berlin in the past two decades. The latest operational developments were the multispectral aureole- and sunphotometer FUBISS-ASA2, the zenith radiometer FUBISS-ZENITH, and the nadir polarimeter AMSSP-EM, all designed for a flexible use on moving platforms like aircraft or ships. Currently the multiangle, multispectral radiometer URMS/AMSSP (Universal Radiation Measurement System/ Airborne Multispectral Sunphotometer and Polarimeter) is under construction for a Wing-Pod of the high altitude research aircraft HALO operated by DLR. The system is expected to have its first mission on HALO in 2011. The algorithms for the retrieval of aerosol and trace gas properties from the recorded multidirectional, multispectral radiation measurements allow more than deriving standard products, as for instance the aerosol optical depth and the Angstrom exponent. The radiation measured in the solar aureole contains information about the aerosol phasefunction and therefore allows conclusions about the particle type. Furthermore, airborne instrument operation allows vertically resolved measurements. An inversion algorithm, based on radiative transfer simulations and additionally including measured vertical zenith-radiance profiles, allows conclusions about the aerosol single scattering albedo and the relative soot fraction in aerosol layers. Ozone column retrieval is performed evaluating measurements from pixels in the Chappuis absorption band. A retrieval algorithm to derive the water-vapor column from the sunphotometer measurements is currently under development. Of the various airborne

  7. Synthesis of pentamidine labelled with tritium and carbon-14

    Energy Technology Data Exchange (ETDEWEB)

    Hesk, D.; Jones, J.R. (Surrey Univ., Guildford (UK). Dept. of Chemistry); Lockley, W.J.S.; Wilkinson, D.J. (Fisons plc, Loughborough (UK). Pharmaceutical Div.)

    1990-11-01

    Tritium labelled pentamidine has been prepared with a specific activity of 90 mCi mmol{sup -1} using a one-step exchange reaction between the unlabelled drug and tritiated water. The labelling utilised a homogeneous rhodium trichloride catalyst and yielded pentamidine regiospecifically labelled in the positions ortho to the amidine groups. Carbon-14 labelled pentamidine was prepared via a seven-step procedure in which the isotope was introduced via a nucleophilic substitution of 4-bromo-phenol with copper(I) ({sup 14}C)cyanide. (author).

  8. Pesticide Product Label System

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Pesticide Product Label System (PPLS) provides a collection of pesticide product labels (Adobe PDF format) that have been approved by EPA under Section 3 of the...

  9. Food Label and You

    Medline Plus

    Full Text Available ... has issued final changes to update the Nutrition Facts label for packaged foods. For more information, see Changes to the Nutrition Facts Label . FDA presents an entertaining and educational tool ...

  10. Semiotic labelled deductive systems

    Energy Technology Data Exchange (ETDEWEB)

    Nossum, R.T. [Imperial College of Science, Technology and Medicine, London (United Kingdom)

    1996-12-31

    We review the class of Semiotic Models put forward by Pospelov, as well as the Labelled Deductive Systems developed by Gabbay, and construct an embedding of Semiotic Models into Labelled Deductive Systems.

  11. Electronic Submission of Labels

    Science.gov (United States)

    Pesticide registrants can provide draft and final labels to EPA electronically for our review as part of the pesticide registration process. The electronic submission of labels by registrants is voluntary but strongly encouraged.

  12. Mental Labels and Tattoos

    Science.gov (United States)

    Hyatt, I. Ralph

    1977-01-01

    Discusses the ease with which mental labels become imprinted in our system, six basic axioms for maintaining negative mental tattoos, and psychological processes for eliminating mental tattoos and labels. (RK)

  13. Limits of Precipitation Detection from Microwave Radiometers and Sounders

    Science.gov (United States)

    Munchak, S. J.; Skofronick-Jackson, G.; Johnson, B. T.

    2012-04-01

    The Global Precipitation Measurement (GPM) mission will unify and draw from numerous microwave conical scanning imaging radiometers and cross-track sounders, many of which already in operation, to provide near real-time precipitation estimates worldwide at 3-hour intervals. Some of these instruments were designed for primary purposes unrelated to precipitation remote sensing. Therefore it is worthwhile to evaluate the strengths and weaknesses of each set of channels with respect to precipitation detection to fully understand their role in the GPM constellation. The GPM radiometer algorithm will use an observationally-based Bayesian retrieval with common databases of precipitation profiles for all sensors. Since these databases are still under development and will not be truly complete until the GPM core satellite has completed at least one year of dual-frequency radar observations, a screening method based upon retrieval of non-precipitation parameters related to the surface and atmospheric state is used in this study. A cost function representing the departure of modeled radiances from their observed values plus the departure of surface and atmospheric parameters from the TELSEM emissivity atlas and MERRA reanalysis is used as an indicator of precipitation. Using this method, two datasets are used to evaluate precipitation detection: One year of matched AMSR-E and AMSU-B/MHS overpasses with CloudSat used as validation globally; and SSMIS overpasses over the United States using the National Mosaic and QPE (NMQ) as validation. The Heidke Skill Score (HSS) is used as a metric to evaluate detection skill over different surfaces, seasons, and across different sensors. Non-frozen oceans give the highest HSS for all sensors, followed by bare land and coasts, then snow-covered land and sea ice. Negligible skill is present over ice sheets. Sounders tend to have higher skill than imagers over complex surfaces (coast, snow, and sea ice), whereas imagers have higher skill

  14. Cloud thermodynamic phase detection with polarimetrically sensitive passive sky radiometers

    Directory of Open Access Journals (Sweden)

    K. Knobelspiesse

    2014-12-01

    Full Text Available The primary goal of this project has been to investigate if ground-based visible and near-infrared passive radiometers that have polarization sensitivity can determine the thermodynamic phase of overlying clouds, i.e. if they are comprised of liquid droplets or ice particles. While this knowledge is important by itself for our understanding of the global climate, it can also help improve cloud property retrieval algorithms that use total (unpolarized radiance to determine Cloud Optical Depth (COD. This is a potentially unexploited capability of some instruments in the NASA Aerosol Robotic Network (AERONET, which, if practical, could expand the products of that global instrument network at minimal additional cost. We performed simulations that found, for zenith observations, cloud thermodynamic phase is often expressed in the sign of the Q component of the Stokes polarization vector. We chose our reference frame as the plane containing solar and observation vectors, so the sign of Q indicates the polarization direction, parallel (positive or perpendicular (negative to that plane. Since the quantity of polarization is inversely proportional to COD, optically thin clouds are most likely to create a signal greater than instrument noise. Besides COD and instrument accuracy, other important factors for the determination of cloud thermodynamic phase are the solar and observation geometry (scattering angles between 40 and 60° are best, and the properties of ice particles (pristine particles may have halos or other features that make them difficult to distinguish from water droplets at specific scattering angles, while extreme ice crystal aspect ratios polarize more than compact particles. We tested the conclusions of our simulations using data from polarimetrically sensitive versions of the Cimel 318 sun photometer/radiometer that comprise AERONET. Most algorithms that exploit Cimel polarized observations use the Degree of Linear Polarization (Do

  15. A Label to Regulate

    DEFF Research Database (Denmark)

    Tricoire, Aurélie; Boxenbaum, Eva; Laurent, Brice

    This paper examines the role labelling plays in the government of the contemporary economy.1Drawing on a detailed study of BBC-Effinergy, a French label for sustainable construction, we showhow the adoption and evolution of voluntary labels can be seen as emblematic of a governmentthrough experim...... experiment engaging 4 operations: stimulating market anticipations, focussing politicalconsultations, producing collective expertise and containing the regulatory transcription of the label....

  16. SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L [Retired from City of Hope Medical Center, Arcadia, CA (United States)

    2014-06-01

    Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

  17. Calibration approach and plan for the sea and land surface temperature radiometer

    Science.gov (United States)

    Smith, David L.; Nightingale, Tim J.; Mortimer, Hugh; Middleton, Kevin; Edeson, Ruben; Cox, Caroline V.; Mutlow, Chris T.; Maddison, Brian J.; Coppo, Peter

    2014-01-01

    The sea and land surface temperature radiometer (SLSTR) to be flown on the European Space Agency's (ESA) Sentinel-3 mission is a multichannel scanning radiometer that will continue the 21 year dataset of the along-track scanning radiometer (ATSR) series. As its name implies, measurements from SLSTR will be used to retrieve global sea surface temperatures to an uncertainty of SLSTR instrument, the infrared calibration sources, and the alignment equipment. The calibration rig has been commissioned and results of these tests will be presented. Finally, the authors will present the planning for the on-orbit monitoring and calibration activities to ensure that the calibration is maintained. These activities include vicarious calibration techniques that have been developed through previous missions and the deployment of ship-borne radiometers.

  18. Geosynchronous Microwave Atmospheric Sounding Radiometer (MASR) feasibility studies. Volume 1: Management summary

    Science.gov (United States)

    1978-01-01

    The mission of the microwave atmospheric sounding radiometer (MASR) is to collect data to aid in the observation and prediction of severe storms. The geosynchronous orbit allows the continuous atmospheric measurement needed to resolve mesoscale dynamics. The instrument may operate in conjunction with this document, Volume 1 - Management, which summarizes the highlights of final reports on both the radiometer instrument and antenna studies. The radiometer instrument summary includes a synopsis of Volume 2 - Radiometer Receiver Feasibility, including design, recommended configuration, performance estimates, and weight and power estimates. The summary of the antenna study includes a synopsis of Volume 3 - Antenna Feasibility, including preliminary design tradeoffs, performance of selected design, and details of the mechanical/thermal design.

  19. AVHRR Orbital Segment = NOAA's Advanced Very High Resolution Radiometer Files: 1992 - 2000

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Advanced Very High Resolution Radiometer (AVHRR) data set is comprised of data collected by the AVHRR sensor and held in the archives of the USGS Earth Resources...

  20. AVHRR Orbital Segment = NOAA's Advanced Very High Resolution Radiometer Files: 1992 - 2000

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Advanced Very High Resolution Radiometer (AVHRR) data set is comprised of data collected by the AVHRR sensor and held in the archives of the USGS Earth...

  1. An optical scanning subsystem for a UAS-enabled hyperspectral radiometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — A hyperspectral visible radiometer instrument system has been developed for use on UAS platforms.  It has been successfully flown on three previous UAS field...

  2. AVHRR Orbital Segment = NOAA's Advanced Very High Resolution Radiometer Files: 1992 - 2000

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The Advanced Very High Resolution Radiometer (AVHRR) data set is comprised of data collected by the AVHRR sensor and held in the archives of the USGS Earth Resources...

  3. An imaging radiometer for measurement of lunar polar cold trap temperatures

    Science.gov (United States)

    Lucey, Paul G.; Blasius, Karl R.; Bussey, Ben; Hoelter, Roger L.; Gillis, Jeffrey J.; Lawson, Stefanie L.; Mellon, Michael; Spencer, John; Urquhart, Mary; Vasavada, Ashwin R.; Wang, Angel T.

    2004-12-01

    The LRO Radiometer Investigation is an experiment proposed for NASA"s Lunar Reconnaisance Orbiter mission that will use a simple but extremely sensitive radiometer to measure the temperatures of the region of permanent shade at the lunar poles. Temperature governs the ability of these surfaces to act as cold traps, and tightly constrains the identity and lifetimes of potential volatile resources. The LRO Radiometer will also measure the night time temperature of the Moon, and use the extensive modeling experience of the team to use these data to produce maps of meter-scale rocks that constitute a significant hazard to landing and operations. The LRO Radiometer also supports LRO objectives by measuring the global abundance of meter scale rocks at 1 km resolution. This measurement is accomplished in four (4) months of observations.

  4. Reducing Broadband Shortwave Radiometer Calibration-Bias Caused by Longwave Irradiance in the Reference Direct Beam

    Energy Technology Data Exchange (ETDEWEB)

    Reda, Ibrahim; Andreas, Afshin; Dooraghi, Mike; Sengupta, Manajit; Habte, Aron; Kutchenreiter, Mark

    2017-01-01

    Shortwave radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to consensus reference, maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, and measures the extended broadband spectrum of the terrestrial direct solar beam irradiance, unlike shortwave radiometers that cover a limited range of the spectrum. The difference between the two spectral ranges may lead to calibration bias that can exceed 1%. This article describes a method to reduce the calibration bias resulting from using broadband ACRs to calibrate shortwave radiometers, by using an ACR with Schott glass window to measure the reference broadband shortwave irradiance in the terrestrial direct solar beam from 0.3 um to 3 um.

  5. An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

    Science.gov (United States)

    Gagliano, J. A.; Platt, R. H.

    1985-01-01

    A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

  6. Evaluating Solar Resource Data Obtained from Multiple Radiometers Deployed at the National Renewable Energy Laboratory: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Sengupta, M.; Andreas, A.; Wilcox, S.; Stoffel, T.

    2014-09-01

    Solar radiation resource measurements from radiometers are used to predict and evaluate the performance of photovoltaic and concentrating solar power systems, validate satellite-based models for estimating solar resources, and advance research in solar forecasting and climate change. This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances (GHI) and direct normal irradiances (DNI). These include pyranometers, pyrheliometers, rotating shadowband irradiometers, and a pyranometer with a shading ring deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory (SRRL). The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference GHI and DNI.

  7. AVHRR Composites = Advanced Very High Resolution Radiometer U.S. Alaska: 1989 - Present

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Normalized Difference Vegetation Index (NDVI) Composites are produced from multiple Advanced Very High Resolution Radiometer (AVHRR) daily observations that have...

  8. Realization of photometric base unit of candela traceable to cryogenic radiometer at UME

    Science.gov (United States)

    Samedov, F.; Bazkır, Ö.

    2005-06-01

    At National Metrology Institute of Turkey (UME, Ulusal Metroloji Enstitüsü), luminous intensity unit of candela was realized using detector-based approach and photometric scale was re-established depending on this new realization. Candela was measured on photometric bench using interferometric distance measurement system and filter-radiometer traceable to UME primary level electrical-substitution cryogenic radiometer. Thermally stabilized filter radiometer, which has been designed for spectral irradiance measurements, is consists of trap detector, filter housing and precision aperture. Different measurement techniques were used to fully characterize each parameter of filter-radiometer; like effective aperture area, spectral transmittance of V(λ) filter and responsivity of trap detector.

  9. Total ozone retrieval from satellite multichannel filter radiometer measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lovill, J.E.; Sullivan, T.J.; Weichel, R.L.; Ellis, J.S.; Huebel, J.G.; Korver, J.; Weidhaas, P.P.; Phelps, F.A.

    1978-05-25

    A total ozone retrieval model has been developed to process radiance data gathered by a satellite-mounted multichannel filter radiometer (MFR). Extensive effort went into theoretical radiative transfer modeling, a retrieval scheme was developed, and the technique was applied to the MFR radiance measurements. The high quality of the total ozone retrieval results was determined through comparisons with Dobson measurements. Included in the report are global total ozone maps for 20 days between May 12 and July 5, 1977. A comparison of MFR results for 13 days in June 1977 with Dobson spectrophotometer measurements of ozone for the same period showed good agreement: there was a root-mean-square difference of 6.2% (equivalent to 20.2 m.atm.cm). The estimated global total ozone value for June 1977 (296 m.atm.cm) was in good agreement with satellite backscatter ultraviolet data for June 1970 (304 m.atm.cm) and June 1971 (preliminary data--299 m.atm.cm).

  10. Thermal Modeling and Analysis of the Hurricane Imaging Radiometer (HIRad)

    Science.gov (United States)

    Mauro, Stephanie

    2013-01-01

    The Hurricane Imaging Radiometer (HIRad) is a payload carried by an unmanned aerial vehicle (UAV) at altitudes up to 60,000 ft with the purpose of measuring ocean surface wind speeds and near ocean surface rain rates in hurricanes. The payload includes several components that must maintain steady temperatures throughout the flight. Minimizing the temperature drift of these components allows for accurate data collection and conclusions to be drawn concerning the behavior of hurricanes. HIRad has flown on several different UAVs over the past two years during the fall hurricane season. Based on the data from the 2011 flight, a Thermal Desktop model was created to simulate the payload and reproduce the temperatures. Using this model, recommendations were made to reduce the temperature drift through the use of heaters controlled by resistance temperature detector (RTD) sensors. The suggestions made were implemented for the 2012 hurricane season and further data was collected. The implementation of the heaters reduced the temperature drift for a portion of the flight, but after a period of time, the temperatures rose. With this new flight data, the thermal model was updated and correlated. Detailed analysis was conducted to determine a more effective way to reduce the temperature drift. The final recommendations made were to adjust the set temperatures of the heaters for 2013 flights and implement hardware changes for flights beyond 2013.

  11. Planar electrical-substitution carbon nanotube cryogenic radiometer

    Science.gov (United States)

    Tomlin, N. A.; White, M.; Vayshenker, I.; Woods, S. I.; Lehman, J. H.

    2015-04-01

    We have developed a fully-lithographic electrical-substitution planar bolometric-radiometer (PBR) that employs multiwall vertically-aligned carbon nanotubes (VACNT) as the absorber and thermistor, micro-machined Si as the weak thermal link and thin-film Mo as the electrical heater. The near-unity absorption of the VACNT over a broad wavelength range permits a planar geometry, compatible with lithographic fabrication. We present performance results on a PBR with an absorption of 0.999 35 at 1550 nm, a thermal conductance of 456 µW K-1 at 4 K and a time constant (1/e) of 7.7 ms. A single measurement of approximately 100 µW optical power at 1550 nm achieved in less than 100 s yields an expanded uncertainty of 0.14% (k = 2). We also observe an elevated superconducting transition temperature of 3.884 K for the Mo heater, which opens the possibility of future devices incorporating more sensitive thermistors and superconducting thin-film wiring. Contribution of an agency of the US government; not subject to copyright

  12. The Planck-LFI Radiometer Electronics Box Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Herreros, J M; Gomez, M F; Rebolo, R; Chulani, H; Rubino-Martin, J A; Hildebrandt, S R [Instituto de Astrofisica de Canarias (IAC), 38200 La Laguna, Tenerife (Spain); Bersanelli, M; Franceschet, C [Universita di Milano, Dipartamento di Fisica, Via G. Celoria 16, 20133 Milano (Italy); Butler, R C [INAF-IASF Bologna, Via P. Gobetti 101, 40129 Bologna (Italy); Miccolis, M [Thales Alenia Space Italia S.p.A., IUEL - Scientific Instruments, S.S. Padana Superiore 290, 20090 Vimodrone (Italy); Pena, A; Pereira, M; Torrero, F; Lopez, M; Alcala, C, E-mail: rrl@iac.e [EADS Astrium CRISA, C/Torres Quevedo, 9, 28760 Tres Cantos (Spain)

    2009-12-15

    The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art processors, communication interfaces and real time operating system software in order to meet the scientific performance of the LFI. We present a technical summary of the REBA, including a physical, functional, electrical, mechanical and thermal description. Aspects of the design and development, the assembly, the integration and the verification of the equipment are provided. A brief description of the LFI on board software is given including the Low-Level Software and the main functionalities and architecture of the Application Software. The compressor module, which has been developed as an independent product, later integrated in the application, is also described in this paper. Two identical engineering models EM and AVM, the engineering qualification model EQM, the flight model FM and flight spare have been manufactured and tested. Low-level and Application software have been developed. Verification activities demonstrated that the REBA hardware and software fulfil all the specifications and perform as required for flight operation.

  13. CIRiS: Compact Infrared Radiometer in Space

    Science.gov (United States)

    Osterman, D. P.; Collins, S.; Ferguson, J.; Good, W.; Kampe, T.; Rohrschneider, R.; Warden, R.

    2016-09-01

    The Compact Infrared Radiometer in Space (CIRiS) is a thermal infrared radiometric imaging instrument under development by Ball Aerospace for a Low Earth Orbit mission on a CubeSat spacecraft. Funded by the NASA Earth Science Technology Office's In-Space Validation of Earth Science Technology (InVEST) program, the mission objective is technology demonstration for improved on-orbit radiometric calibration. The CIRiS calibration approach uses a scene select mirror to direct three calibration views to the focal plane array and to transfer the resulting calibrated response to earth images. The views to deep space and two blackbody sources, including one at a selectable temperature, provide multiple options for calibration optimization. Two new technologies, carbon nanotube blackbody sources and microbolometer focal plane arrays with reduced pixel sizes, enable improved radiometric performance within the constrained 6U CubeSat volume. The CIRiS instrument's modular design facilitates subsystem modifications as required by future mission requirements. CubeSat constellations of CIRiS and derivative instruments offer an affordable approach to achieving revisit times as short as one day for diverse applications including water resource and drought management, cloud, aerosol, and dust studies, and land use and vegetation monitoring. Launch is planned for 2018.

  14. The MASCOT Radiometer MARA for the Hayabusa 2 Mission

    Science.gov (United States)

    Grott, M.; Knollenberg, J.; Borgs, B.; Hänschke, F.; Kessler, E.; Helbert, J.; Maturilli, A.; Müller, N.

    2017-07-01

    The MASCOT radiometer MARA is a multi-spectral instrument which measures net radiative flux in six wavelength bands. MARA uses thermopile sensors as sensing elements, and the net flux between the instrument and the surface in the 18° field of view is determined by evaluating the thermoelectric potential between the sensors' absorbing surface and the thermopile's cold-junction. MARA houses 4 bandpass channels in the spectral range of 5.5-7, 8-9.5, 9.5-11.5, and 13.5-15.5 μm, as well as one long-pass channel, which is sensitive in the >3 μm range. In addition, one channel is similar to that used by the Hayabusa 2 orbiter thermal mapper, which uses a wavelength range of 8-12 μm. The primary science objective of the MARA instrument it the determination of the target asteroid's surface brightness temperature, from which surface thermal inertia can be derived. In addition, the spectral bandpass channels will be used to estimate the spectral slope of the surface in the thermal infrared wavelength range. The instrument has been calibrated using a cavity blackbody, and the temperature uncertainty is 1 K in the long pass channel for target temperatures of >173 K. Measurement uncertainty in the spectral bandpasses is 1 K for target temperatures above 273 K.

  15. Advanced Very High Resolution Radiometer Normalized Difference Vegetation Index Composites

    Science.gov (United States)

    ,

    2005-01-01

    The Advanced Very High Resolution Radiometer (AVHRR) is a broad-band scanner with four to six bands, depending on the model. The AVHRR senses in the visible, near-, middle-, and thermal- infrared portions of the electromagnetic spectrum. This sensor is carried on a series of National Oceanic and Atmospheric Administration (NOAA) Polar Orbiting Environmental Satellites (POES), beginning with the Television InfraRed Observation Satellite (TIROS-N) in 1978. Since 1989, the United States Geological Survey (USGS) Center for Earth Resources Observation and Science (EROS) has been mapping the vegetation condition of the United States and Alaska using satellite information from the AVHRR sensor. The vegetation condition composites, more commonly called greenness maps, are produced every week using the latest information on the growth and condition of the vegetation. One of the most important aspects of USGS greenness mapping is the historical archive of information dating back to 1989. This historical stretch of information has allowed the USGS to determine a 'normal' vegetation condition. As a result, it is possible to compare the current week's vegetation condition with normal vegetation conditions. An above normal condition could indicate wetter or warmer than normal conditions, while a below normal condition could indicate colder or dryer than normal conditions. The interpretation of departure from normal will depend on the season and geography of a region.

  16. The MASCOT Radiometer MARA for the Hayabusa 2 Mission

    Science.gov (United States)

    Grott, M.; Knollenberg, J.; Borgs, B.; Hänschke, F.; Kessler, E.; Helbert, J.; Maturilli, A.; Müller, N.

    2016-08-01

    The MASCOT radiometer MARA is a multi-spectral instrument which measures net radiative flux in six wavelength bands. MARA uses thermopile sensors as sensing elements, and the net flux between the instrument and the surface in the 18° field of view is determined by evaluating the thermoelectric potential between the sensors' absorbing surface and the thermopile's cold-junction. MARA houses 4 bandpass channels in the spectral range of 5.5-7, 8-9.5, 9.5-11.5, and 13.5-15.5 μm, as well as one long-pass channel, which is sensitive in the >3 μm range. In addition, one channel is similar to that used by the Hayabusa 2 orbiter thermal mapper, which uses a wavelength range of 8-12 μm. The primary science objective of the MARA instrument it the determination of the target asteroid's surface brightness temperature, from which surface thermal inertia can be derived. In addition, the spectral bandpass channels will be used to estimate the spectral slope of the surface in the thermal infrared wavelength range. The instrument has been calibrated using a cavity blackbody, and the temperature uncertainty is 1 K in the long pass channel for target temperatures of >173 K. Measurement uncertainty in the spectral bandpasses is 1 K for target temperatures above 273 K.

  17. Next-generation pushbroom filter radiometers for remote sensing

    Science.gov (United States)

    Tarde, Richard W.; Dittman, Michael G.; Kvaran, Geir E.

    2012-09-01

    Individual focal plane size, yield, and quality continue to improve, as does the technology required to combine these into large tiled formats. As a result, next-generation pushbroom imagers are replacing traditional scanning technologies in remote sensing applications. Pushbroom architecture has inherently better radiometric sensitivity and significantly reduced payload mass, power, and volume than previous generation scanning technologies. However, the architecture creates challenges achieving the required radiometric accuracy performance. Achieving good radiometric accuracy, including image spectral and spatial uniformity, requires creative optical design, high quality focal planes and filters, careful consideration of on-board calibration sources, and state-of-the-art ground test facilities. Ball Aerospace built the Landsat Data Continuity Mission (LDCM) next-generation Operational Landsat Imager (OLI) payload. Scheduled to launch in 2013, OLI provides imagery consistent with the historical Landsat spectral, spatial, radiometric, and geometric data record and completes the generational technology upgrade from the Enhanced Thematic Mapper (ETM+) whiskbroom technology to modern pushbroom technology afforded by advanced focal planes. We explain how Ball's capabilities allowed producing the innovative next-generational OLI pushbroom filter radiometer that meets challenging radiometric accuracy or calibration requirements. OLI will improve the multi-decadal land surface observation dataset dating back to the 1972 launch of ERTS-1 or Landsat 1.

  18. Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-11-21

    Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibration service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These

  19. Labeling Schemes with Queries

    OpenAIRE

    2006-01-01

    We study the question of ``how robust are the known lower bounds of labeling schemes when one increases the number of consulted labels''. Let $f$ be a function on pairs of vertices. An $f$-labeling scheme for a family of graphs $\\cF$ labels the vertices of all graphs in $\\cF$ such that for every graph $G\\in\\cF$ and every two vertices $u,v\\in G$, the value $f(u,v)$ can be inferred by merely inspecting the labels of $u$ and $v$. This paper introduces a natural generalization: the notion of $f$-...

  20. Analisys of noise-injection networks for interferometric-radiometer calibration

    OpenAIRE

    Corbella Sanahuja, Ignasi; Camps Carmona, Adriano José; Torres Torres, Francisco; Bará Temes, Francisco Javier

    2000-01-01

    Abstract: The spatial resolution of current space-borne Earth observation radiometers is limited by the physical antenna aperture. This is especially critical at L-band, which exhibits high sensitivity to soil moisture and sea surface salinity. Interferometric radiometers (InR's) are currently being studied by several space agencies as a feasible alternative to overcome this problem. However, their calibration is a crucial issue since most techniques inherited from radio astronomy cannot b...

  1. Simultaneous Estimation of Geophysical Parameters with Microwave Radiometer Data based on Accelerated Simulated Annealing: SA

    Directory of Open Access Journals (Sweden)

    Kohei Arai

    2012-07-01

    Full Text Available Method for geophysical parameter estimations with microwave radiometer data based on Simulated Annealing: SA is proposed. Geophysical parameters which are estimated with microwave radiometer data are closely related each other. Therefore simultaneous estimation makes constraints in accordance with the relations. On the other hand, SA requires huge computer resources for convergence. In order to accelerate convergence process, oscillated decreasing function is proposed for cool down function. Experimental results show that remarkable improvements are observed for geophysical parameter estimations.

  2. On Emissivity of Reference Source of IR Radiometer for Remote Sensing

    OpenAIRE

    高木, 亨; 松井, 松長; 宮武, 将浩; タカギ, トオル; マツイ, マツナガ; ミヤタケ, マサヒロ; Tohru, TAKAGI; Matsunaga, MATSUI; Masahiro, MIYATAKE

    1980-01-01

    The reference source of the radiometer for remote sensing should be small and light the emissivity high and the field of view of the optical system wide. In this paper, the theoretical and experimental consideration on emissivity of the cavity type reference source of radiometer for remote sensing is performed. The results are as follows: 1) The simplified equation for calculation of emissivity of cavity type source is introduced. 2) The equation for emissivity of cavity type source at variou...

  3. Comparative study of radiochemical purity of Neurolite 1, Ceretec1, Cerestab 1 preparations labelled with {sup 99m}Tc in function of time and activity used; Etude comparative de la stabilite de la purete radiochimique de preparations de Neurolite1, Ceretec1 et Cerestab1 marquees au {sup 99m}Tc en fonction du temps et de l'activite utilisee

    Energy Technology Data Exchange (ETDEWEB)

    Lemoine, E.; Lopez, V.; Giraud, F.; Pisano, P. [CHU Timone, Service de radiopharmacie, 13 - Marseille (France)

    2010-07-01

    the radiochemical purity (R.C.P.) of the 'Ceretec' and the 'Cerestab' labelled by a {sup 99}Tc activity up to 3.7 GBq is satisfying 10 mn after the labelling, however, it becomes under 90% if the activity used goes over 3.7 GBq. The R.C.P. of the 'Cerestab labelled with an activity over 1 GBq is not stable on 6 hours. (N.C.)

  4. CAROLS: a new airborne L-band radiometer for ocean surface and land observations.

    Science.gov (United States)

    Zribi, Mehrez; Pardé, Mickael; Boutin, Jacquline; Fanise, Pascal; Hauser, Daniele; Dechambre, Monique; Kerr, Yann; Leduc-Leballeur, Marion; Reverdin, Gilles; Skou, Niels; Søbjærg, Sten; Albergel, Clement; Calvet, Jean Christophe; Wigneron, Jean Pierre; Lopez-Baeza, Ernesto; Rius, Antonio; Tenerelli, Joseph

    2011-01-01

    The "Cooperative Airborne Radiometer for Ocean and Land Studies" (CAROLS) L-Band radiometer was designed and built as a copy of the EMIRAD II radiometer constructed by the Technical University of Denmark team. It is a fully polarimetric and direct sampling correlation radiometer. It is installed on board a dedicated French ATR42 research aircraft, in conjunction with other airborne instruments (C-Band scatterometer-STORM, the GOLD-RTR GPS system, the infrared CIMEL radiometer and a visible wavelength camera). Following initial laboratory qualifications, three airborne campaigns involving 21 flights were carried out over South West France, the Valencia site and the Bay of Biscay (Atlantic Ocean) in 2007, 2008 and 2009, in coordination with in situ field campaigns. In order to validate the CAROLS data, various aircraft flight patterns and maneuvers were implemented, including straight horizontal flights, circular flights, wing and nose wags over the ocean. Analysis of the first two campaigns in 2007 and 2008 leads us to improve the CAROLS radiometer regarding isolation between channels and filter bandwidth. After implementation of these improvements, results show that the instrument is conforming to specification and is a useful tool for Soil Moisture and Ocean Salinity (SMOS) satellite validation as well as for specific studies on surface soil moisture or ocean salinity.

  5. CAROLS: A New Airborne L-Band Radiometer for Ocean Surface and Land Observations

    Directory of Open Access Journals (Sweden)

    Ernesto Lopez-Baeza

    2011-01-01

    Full Text Available The “Cooperative Airborne Radiometer for Ocean and Land Studies” (CAROLS L-Band radiometer was designed and built as a copy of the EMIRAD II radiometer constructed by the Technical University of Denmark team. It is a fully polarimetric and direct sampling correlation radiometer. It is installed on board a dedicated French ATR42 research aircraft, in conjunction with other airborne instruments (C-Band scatterometer—STORM, the GOLD-RTR GPS system, the infrared CIMEL radiometer and a visible wavelength camera. Following initial laboratory qualifications, three airborne campaigns involving 21 flights were carried out over South West France, the Valencia site and the Bay of Biscay (Atlantic Ocean in 2007, 2008 and 2009, in coordination with in situ field campaigns. In order to validate the CAROLS data, various aircraft flight patterns and maneuvers were implemented, including straight horizontal flights, circular flights, wing and nose wags over the ocean. Analysis of the first two campaigns in 2007 and 2008 leads us to improve the CAROLS radiometer regarding isolation between channels and filter bandwidth. After implementation of these improvements, results show that the instrument is conforming to specification and is a useful tool for Soil Moisture and Ocean Salinity (SMOS satellite validation as well as for specific studies on surface soil moisture or ocean salinity.

  6. CAROLS: A New Airborne L-Band Radiometer for Ocean Surface and Land Observations

    Science.gov (United States)

    Zribi, Mehrez; Pardé, Mickael; Boutin, Jacquline; Fanise, Pascal; Hauser, Daniele; Dechambre, Monique; Kerr, Yann; Leduc-Leballeur, Marion; Reverdin, Gilles; Skou, Niels; Søbjærg, Sten; Albergel, Clement; Calvet, Jean Christophe; Wigneron, Jean Pierre; Lopez-Baeza, Ernesto; Rius, Antonio; Tenerelli, Joseph

    2011-01-01

    The “Cooperative Airborne Radiometer for Ocean and Land Studies” (CAROLS) L-Band radiometer was designed and built as a copy of the EMIRAD II radiometer constructed by the Technical University of Denmark team. It is a fully polarimetric and direct sampling correlation radiometer. It is installed on board a dedicated French ATR42 research aircraft, in conjunction with other airborne instruments (C-Band scatterometer—STORM, the GOLD-RTR GPS system, the infrared CIMEL radiometer and a visible wavelength camera). Following initial laboratory qualifications, three airborne campaigns involving 21 flights were carried out over South West France, the Valencia site and the Bay of Biscay (Atlantic Ocean) in 2007, 2008 and 2009, in coordination with in situ field campaigns. In order to validate the CAROLS data, various aircraft flight patterns and maneuvers were implemented, including straight horizontal flights, circular flights, wing and nose wags over the ocean. Analysis of the first two campaigns in 2007 and 2008 leads us to improve the CAROLS radiometer regarding isolation between channels and filter bandwidth. After implementation of these improvements, results show that the instrument is conforming to specification and is a useful tool for Soil Moisture and Ocean Salinity (SMOS) satellite validation as well as for specific studies on surface soil moisture or ocean salinity. PMID:22346599

  7. Succesful labelling schemes

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Stacey, Julia

    2001-01-01

    It is usual practice to evaluate the success of a labelling scheme by looking at the awareness percentage, but in many cases this is not sufficient. The awareness percentage gives no indication of which of the consumer segments that are aware of and use labelling schemes and which do not. In the ......It is usual practice to evaluate the success of a labelling scheme by looking at the awareness percentage, but in many cases this is not sufficient. The awareness percentage gives no indication of which of the consumer segments that are aware of and use labelling schemes and which do not....... In the spring of 2001 MAPP carried out an extensive consumer study with special emphasis on the Nordic environmentally friendly label 'the swan'. The purpose was to find out how much consumers actually know and use various labelling schemes. 869 households were contacted and asked to fill in a questionnaire...... it into consideration when I go shopping. The respondent was asked to pick the most suitable answer, which described her use of each label. 29% - also called 'the labelling blind' - responded that they basically only knew the recycling label and the Government controlled organic label 'Ø-mærket'. Another segment of 6...

  8. Low Power Silicon Germanium Electronics for Microwave Radiometers

    Science.gov (United States)

    Doiron, Terence A.; Krebs, Carolyn (Technical Monitor)

    2001-01-01

    Space-based radiometric observations of key hydrological parameters (e.g., soil moisture) at the spatial and temporal scales required in the post-2002 era face significant technological challenges. These measurements are based on relatively low frequency thermal microwave emission (at 1.4 GHz for soil moisture and salinity, 10 GHz and up for precipitation, and 19 and 37 GHz for snow). The long wavelengths at these frequencies coupled with the high spatial and radiometric resolutions required by the various global hydrology communities necessitate the use of very large apertures (e.g., greater than 20 m at 1.4 GHz) and highly integrated stable RF electronics on orbit. Radio-interferometric techniques such as Synthetic Thinned Array Radiometry (STAR), using silicon germanium (SiGe) low power radio frequency integrated circuits (RFIC), is one of the most promising technologies to enable very large non-rotating apertures in space. STAR instruments are composed of arrays of small antenna/receiving elements that are arranged so that the collecting area is smaller than an equivalent real aperture system, allowing very high packing densities for launch. A 20 meter aperture at L-band, for example, will require greater than 1000 of these receiving elements. SiGe RFIC's reduce power consumption enough to make an array like this possible in the power-limited environment of space flight. An overview of the state-of-the-art will be given, and current work in the area of SiGe radiometer development for soil moisture remote sensing will be discussed.

  9. Spectral responsivity calibrations of two types of pyroelectric radiometers using three different methods

    Science.gov (United States)

    Zeng, J.; Eppeldauer, G. P.; Hanssen, L. M.; Podobedov, V. B.

    2012-06-01

    Spectral responsivity calibrations of two different types of pyroelectric radiometers have been made in the infrared region up to 14 μm in power mode using three different calibration facilities at NIST. One pyroelectric radiometer is a temperature-controlled low noise-equivalent-power (NEP) single-element pyroelectric radiometer with an active area of 5 mm in diameter. The other radiometer is a prototype using the same type of pyroeletric detector with dome-input optics, which was designed to increase absorptance and to minimize spectral structures to obtain a constant spectral responsivity. Three calibration facilities at NIST were used to conduct direct and indirect responsivity calibrations tied to absolute scales in the infrared spectral regime. We report the calibration results for the single-element pyroelectric radiometer using a new Infrared Spectral Comparator Facility (IRSCF) for direct calibration. Also, a combined method using the Fourier Transform Infrared Spectrophotometry (FTIS) facility and single wavelength laser tie-points are described to calibrated standard detectors with an indirect approach. For the dome-input pyroelectric radiometer, the results obtained from another direct calibration method using a circular variable filter (CVF) spectrometer and the FTIS are also presented. The inter-comparison of different calibration methods enables us to improve the responsivity uncertainty performed by the different facilities. For both radiometers, consistent results of the spectral power responsivity have been obtained applying different methods from 1.5 μm to 14 μm with responsivity uncertainties between 1 % and 2 % (k = 2). Relevant characterization results, such as spatial uniformity, linearity, and angular dependence of responsivity, are shown. Validation of the spectral responsivity calibrations, uncertainty sources, and improvements for each method will also be discussed.

  10. Characterization of downwelling radiance measured from a ground-based microwave radiometer using numerical weather prediction model data

    Science.gov (United States)

    Ahn, M.-H.; Won, H. Y.; Han, D.; Kim, Y.-H.; Ha, J.-C.

    2016-01-01

    The ground-based microwave sounding radiometers installed at nine weather stations of Korea Meteorological Administration alongside with the wind profilers have been operating for more than 4 years. Here we apply a process to assess the characteristics of the observation data by comparing the measured brightness temperature (Tb) with reference data. For the current study, the reference data are prepared by the radiative transfer simulation with the temperature and humidity profiles from the numerical weather prediction model instead of the conventional radiosonde data. Based on the 3 years of data, from 2010 to 2012, we were able to characterize the effects of the absolute calibration on the quality of the measured Tb. We also showed that when clouds are present the comparison with the model has a high variability due to presence of cloud liquid water therefore making cloudy data not suitable for assessment of the radiometer's performance. Finally we showed that differences between modeled and measured brightness temperatures are unlikely due to a shift in the selection of the center frequency but more likely due to spectroscopy issues in the wings of the 60 GHz absorption band. With a proper consideration of data affected by these two effects, it is shown that there is an excellent agreement between the measured and simulated Tb. The regression coefficients are better than 0.97 along with the bias value of better than 1.0 K except for the 52.28 GHz channel which shows a rather large bias and variability of -2.6 and 1.8 K, respectively.

  11. 抗犬瘟热病毒荧光标记单抗的制备和初步鉴定%Preparation and Preliminary Identification of Fluorescein Labeled Monoclonal Antibody against Canine Distemper Virus

    Institute of Scientific and Technical Information of China (English)

    苏建青; 褚秀玲; 杨松涛; 夏咸柱; 岳妙姝

    2009-01-01

    [Objective] The aim of the present study was to develop a direct immunofluorescence method for the diagnosis of canine distemper (CD) with FITC-conjugated monoclonal antibodies (FITC-McAb). [Method] The McAb against CDV, designated as CE3, was purified with protein G and labeled with FITC through agitation method. After purification and identification, the optimal working concentration of FITC-labeled CE3 was determined. Then 61 clinical samples of suspected canine distemper were detected by direct immunofluorescence assay. [Result] The absorption test, blocking test and specificity test showed that the labeled antibody had high specificity and sensitivity, but didnt have cross reaction with canine parvovirus (CPV), canine parainfluenza virus (CPIV), canine adenovirus (CAV) and rabies virus (RV). The optimal working concentration was 1∶80. The positive rate of clinical suspected samples was 48%. [Conclusion] The direct immunofluorescence assay developed in this study was rapid, specific and convenient, and had great significance for the early diagnosis of canine distemper.

  12. Evaluation of Radiometers in Full-Time Use at the National Renewable Energy Laboratory Solar Radiation Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, S. M.; Myers, D. R.

    2008-12-01

    This report describes the evaluation of the relative performance of the complement of solar radiometers deployed at the National Renewable Energy Laboratory (NREL) Solar Radiation Research Laboratory (SRRL).

  13. The Radiometer Atmospheric Cubesat Experiment Post-Launch Results

    Science.gov (United States)

    Lim, B.; Misra, S.

    2015-12-01

    The Jet Propulsion Laboratory (JPL) developed the Radiometer Atmospheric CubeSat Experiment (RACE) that was lost during the Orbital 3 (Orb-3) launch anomaly on October 28, 2014. The 3U CubeSat mission would have measured 2 channels of the 183 GHz water vapor line and raised the technology readiness level (TRL) of various subsystems to 6. Despite the launch failure, several hundreds of hours of instrument operation data was taken, including measurements in thermal vacuum of the complete spacecraft system. These data is used to evaluate the 35 nm Indium Phosphide (InP) receivers, and the low noise amplifier (LNA) based internal calibration system. The thermal vacuum measurements included frequent observations of a 'cold' and 'hot' target allowing for various receiver parameters to be calculated. The payload thermal vacuum data show that the receiver front ends performed as expected in terms of the gain (>35 dB) and drift (0.06 dB/K). The data also shows that integration could be performed with decreasing noise up to ~30 seconds, allowing for the system to be calibrated within that time period. The expected spacecraft calibration period would have been every 12 seconds. The injected noise from the load terminated LNA show magnitudes from 50 - 150 K that can be tuned which would meet most requirements. However the temperature coefficient is large at ~3 K/K which is over an order of magnitude larger than typical noise diodes. For nanosatellite class spacecraft, the power required to properly maintain the physical temperature range (±0.1K) would be challenging. On larger spacecraft, this methodology may still be viable, depending on the availability of suitable noise diodes at 183 GHz. While the CubeSat did not take measurements in space, the ground data in the relevant environment and extensive testing allows us to raise the following subsystems to TRL 6: 1) 183 GHz 35 nm InP receiver, 2) 183 GHz direct detect receiver and 3) 183 GHz LNA based calibration system.

  14. Low Average Sidelobe Slot Array Antennas for Radiometer Applications

    Science.gov (United States)

    Rengarajan, Sembiam; Zawardzki, Mark S.; Hodges, Richard E.

    2012-01-01

    In radiometer applications, it is required to design antennas that meet low average sidelobe levels and low average return loss over a specified frequency bandwidth. It is a challenge to meet such specifications over a frequency range when one uses resonant elements such as waveguide feed slots. In addition to their inherent narrow frequency band performance, the problem is exacerbated due to modeling errors and manufacturing tolerances. There was a need to develop a design methodology to solve the problem. An iterative design procedure was developed by starting with an array architecture, lattice spacing, aperture distribution, waveguide dimensions, etc. The array was designed using Elliott s technique with appropriate values of the total slot conductance in each radiating waveguide, and the total resistance in each feed waveguide. Subsequently, the array performance was analyzed by the full wave method of moments solution to the pertinent integral equations. Monte Carlo simulations were also carried out to account for amplitude and phase errors introduced for the aperture distribution due to modeling errors as well as manufacturing tolerances. If the design margins for the average sidelobe level and the average return loss were not adequate, array architecture, lattice spacing, aperture distribution, and waveguide dimensions were varied in subsequent iterations. Once the design margins were found to be adequate, the iteration was stopped and a good design was achieved. A symmetric array architecture was found to meet the design specification with adequate margin. The specifications were near 40 dB for angular regions beyond 30 degrees from broadside. Separable Taylor distribution with nbar=4 and 35 dB sidelobe specification was chosen for each principal plane. A non-separable distribution obtained by the genetic algorithm was found to have similar characteristics. The element spacing was obtained to provide the required beamwidth and close to a null in the E

  15. Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    CERN Document Server

    Villa, F; Sandri, M; Meinhold, P; Poutanen, T; Battaglia, P; Franceschet, C; Hughes, N; Laaninen, M; Lapolla, P; Bersanelli, M; Butler, R C; Cuttaia, F; D'Arcangelo, O; Frailis, M; Franceschi, E; Galeotta, S; Gregorio, A; Leonardi, R; Lowe, S R; Mandolesi, N; Maris, M; Mendes, L; Mennella, A; Morgante, G; Stringhetti, L; Tomasi, M; Valenziano, L; Zacchei, A; Zonca, A; Aja, B; Artal, E; Balasini, M; Bernardino, T; Blackhurst, E; Boschini, L; Cappellini, B; Cavaliere, F; Colin, A; Colombo, F; Davis, R J; De La Fuente, L; Edgeley, J; Gaier, T; Galtress, A; Hoyland, R; Jukkala, P; Kettle, D; Kilpia, V-H; Lawrence, C R; Lawson, D; Leahy, J P; Leutenegger, P; Levin, S; Maino, D; Malaspina, M; Mediavilla, A; Miccolis, M; Pagan, L; Pascual, J P; Pasian, F; Pecora, M; Pospieszalski, M; Roddis, N; Salmon, M J; Seiffert, M; Silvestri, R; Simonetto, A; Sjoman, P; Sozzi, C; Tuovinen, J; Varis, J; Wilkinson, A; Winder, F

    2010-01-01

    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential i...

  16. Food Label and You

    Medline Plus

    Full Text Available ... En Español Search FDA Submit search Popular Content Home Food Drugs Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Food Home Food Ingredients, Packaging & Labeling Labeling & Nutrition The Food ...

  17. Broadband electromagnetic analysis of dispersive, periodic structures for radiometer calibration

    Science.gov (United States)

    Sandeep, S.

    This thesis primarily focusses on the full wave electromagnetic analysis of radiometer calibration targets using doubly dispersive 3D Finite Difference Time Domain (FDTD) formulation. The boundary conditions are set up to solve for doubly periodic structures. The thesis contains very detailed derivation and equations regarding this formulation. One of the novelty in this formulation is the handling of magnetically and electrically dispersive media (usually it is just the electrical dispersion which is incorporated). Using a custom developed code which can be run on a distributed computing system, the reflectivity spectrum of calibration targets of different geometries, coating thicknesses and aspect ratios are analyzed. The results are well validated using commercial simulation softwares and custom Geometric Optics (GO) code. The geometries analyzed include square pyramids, conical pyramids, truncated square pyramids and truncated conical pyramids with spherical top. The coating thicknesses used are 1 mm, 2 mm and 3 mm. The aspect ratios (ratio of base to height) used include 1 : 1, 1 : 2 and 1 : 4. The nominal target structure has 1 : 4 aspect ratio and 2mm coating thickness. The material used for simulation is ECCOSORB MF112. The material properties of other materials such as MF110 and MF114 are listed. It should be remarked that measured material properties are available only in the frequency range [8, 26] GHz and a Debye series extrapolation was used for simulation at frequencies outside this range. Throughout this work 0.5 inch base was used. Some significant conclusions include the following: (1) 1:4 aspect ratio or better is required to achieve a -50 dB reflectivity or lower. (2) Low frequency reflectivity is independent of the target geometry. (3) At high frequencies, the conical target results in better performance when compared to square pyramids (by about 10 dB). (4) The reflectivity spectrum exhibits a general trend of high reflectivity at low

  18. Double-cavity radiometer for high-flux density solar radiation measurements.

    Science.gov (United States)

    Parretta, A; Antonini, A; Armani, M; Nenna, G; Flaminio, G; Pellegrino, M

    2007-04-20

    A radiometric method has been developed, suitable for both total power and flux density profile measurement of concentrated solar radiation. The high-flux density radiation is collected by a first optical cavity, integrated, and driven to a second optical cavity, where, attenuated, it is measured by a conventional radiometer operating under a stationary irradiation regime. The attenuation factor is regulated by properly selecting the aperture areas in the two cavities. The radiometer has been calibrated by a pulsed solar simulator at concentration levels of hundreds of suns. An optical model and a ray-tracing study have also been developed and validated, by which the potentialities of the radiometer have been largely explored.

  19. Pre-flight calibration of LYRA, the solar VUV radiometer on board PROBA2

    Science.gov (United States)

    Benmoussa, A.; Dammasch, I. E.; Hochedez, J.-F.; Schühle, U.; Koller, S.; Stockman, Y.; Scholze, F.; Richter, M.; Kroth, U.; Laubis, C.; Dominique, M.; Kretzschmar, M.; Mekaoui, S.; Gissot, S.; Theissen, A.; Giordanengo, B.; Bolsee, D.; Hermans, C.; Gillotay, D.; Defise, J.-M.; Schmutz, W.

    2009-12-01

    Aims. LYRA, the Large Yield Radiometer, is a vacuum ultraviolet (VUV) solar radiometer, planned to be launched in November 2009 on the European Space Agency PROBA2, the Project for On-Board Autonomy spacecraft. Methods: The instrument was radiometrically calibrated in the radiometry laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the Berlin Electron Storage ring for SYnchroton radiation (BESSY II). The calibration was done using monochromatized synchrotron radiation at PTB's VUV and soft X-ray radiometry beamlines using reference detectors calibrated with the help of an electrical substitution radiometer as the primary detector standard. Results: A total relative uncertainty of the radiometric calibration of the LYRA instrument between 1% and 11% was achieved. LYRA will provide irradiance data of the Sun in four UV passbands and with high temporal resolution down to 10 ms. The present state of the LYRA pre-flight calibration is presented as well as the expected instrument performance.

  20. New improved algorithm for sky calibration of L-band radiometers JLBARA and ELBARA II

    KAUST Repository

    Dimitrov, Marin

    2012-03-01

    We propose a new algorithm for sky calibration of the L-band radiometers JLBARA and ELBARA II, introducing the effective transmissivities of the instruments. The suggested approach was tested using experimental data obtained at the Selhausen test site, Germany. It was shown that for JLBARA the effective transmissivities depend strongly on the air temperature and decrease with increasing air temperature, while for ELBARA II such strong dependence was not observed. It was also shown that the effective transmissivities account for the antenna and feed cable loss effects, and for the variations of the radiometer gain due to air temperature changes. The new calibration algorithm reduces significantly the bias of brightness temperature estimates for both radiometers, especially for JLBARA. © 2012 IEEE.

  1. Optical depth measurements by shadow-band radiometers and their uncertainties.

    Science.gov (United States)

    Alexandrov, Mikhail D; Kiedron, Peter; Michalsky, Joseph J; Hodges, Gary; Flynn, Connor J; Lacis, Andrew A

    2007-11-20

    Shadow-band radiometers in general, and especially the Multi-Filter Rotating Shadow-band Radiometer (MFRSR), are widely used for atmospheric optical depth measurements. The major programs running MFRSR networks in the United States include the Department of Energy Atmospheric Radiation Measurement (ARM) Program, U.S. Department of Agriculture UV-B Monitoring and Research Program, National Oceanic and Atmospheric Administration Surface Radiation (SURFRAD) Network, and NASA Solar Irradiance Research Network (SIRN). We discuss a number of technical issues specific to shadow-band radiometers and their impact on the optical depth measurements. These problems include instrument tilt and misalignment, as well as some data processing artifacts. Techniques for data evaluation and automatic detection of some of these problems are described.

  2. Design of an ultra-portable field transfer radiometer supporting automated vicarious calibration

    Science.gov (United States)

    Anderson, Nikolaus; Thome, Kurtis; Czapla-Myers, Jeffrey; Biggar, Stuart

    2015-09-01

    The University of Arizona Remote Sensing Group (RSG) began outfitting the radiometric calibration test site (RadCaTS) at Railroad Valley Nevada in 2004 for automated vicarious calibration of Earth-observing sensors. RadCaTS was upgraded to use RSG custom 8-band ground viewing radiometers (GVRs) beginning in 2011 and currently four GVRs are deployed providing an average reflectance for the test site. This measurement of ground reflectance is the most critical component of vicarious calibration using the reflectance-based method. In order to ensure the quality of these measurements, RSG has been exploring more efficient and accurate methods of on-site calibration evaluation. This work describes the design of, and initial results from, a small portable transfer radiometer for the purpose of GVR calibration validation on site. Prior to deployment, RSG uses high accuracy laboratory calibration methods in order to provide radiance calibrations with low uncertainties for each GVR. After deployment, a solar radiation based calibration has typically been used. The method is highly dependent on a clear, stable atmosphere, requires at least two people to perform, is time consuming in post processing, and is dependent on several large pieces of equipment. In order to provide more regular and more accurate calibration monitoring, the small portable transfer radiometer is designed for quick, one-person operation and on-site field calibration comparison results. The radiometer is also suited for laboratory calibration use and thus could be used as a transfer radiometer calibration standard for ground viewing radiometers of a RadCalNet site.

  3. Infrared Filter Radiometers for Thermodynamic Temperature Determination below 660 °C

    Science.gov (United States)

    Noulkow, N.; Taubert, R. D.; Meindl, P.; Hollandt, J.

    2009-02-01

    At the Physikalisch-Technische Bundesanstalt (PTB), absolutely-calibrated filter radiometers based on silicon photodiodes are routinely used for thermodynamic temperature determinations of blackbodies in the range from the zinc fixed point (FP) (419 °C) up to 3,000 °C. To extend the temperature range down to the tin FP (232 °C), we have designed two new filter radiometers based on indium gallium arsenide (InGaAs) photodiodes with center wavelengths at 1,300 nm and 1,550 nm. For the absolute calibration of the spectral irradiance responsivity of the new InGaAs filter radiometers, the spectral responsivity measurement in the near-infrared (NIR) spectral range has been significantly improved. With a newly developed tuneable laser and monochromator-based cryogenic radiometer facility, the relative standard uncertainty of the NIR spectral responsivity has been reduced from 0.17 % to about 0.03 %. By using the calibrated InGaAs filter radiometer in conjunction with the large-area double sodium heat pipe of the PTB, the first results for the difference between the thermodynamic temperature T and the ITS-90 temperature T 90 in the temperature range from the zinc FP up to the aluminum FP (660 °C) are presented. The values for T - T 90 determined with the new InGaAs filter radiometers are consistent within their relative standard uncertainty of about 30 mK at 419 °C to about 60 mK at 660 °C.

  4. Total Power Radiometer for Medical Sensor Applications Using Matched and Mismatched Noise Sources.

    Science.gov (United States)

    Park, Woojin; Jeong, Jinho

    2017-09-14

    This paper presents a simple total power radiometer to noninvasively measure the temperature of the human body. The proposed 3-GHz radiometer consists of an antenna collecting the noise power generated by a target, a low-noise and high-gain receiver amplifying the noise power, and a detector converting the noise power to voltage. A single-pole-triple-throw (SP3T) switch is placed between the antenna and the receiver, while a personal computer is used to control the SP3T switch, collect and process the data such as detector output voltages and physical temperatures of the reference noise sources and the target. The fabricated radiometer shows a good performance agreement with a thermometer in the temperature measurement of water from 25.0 to 43.1 °C. For the accurate prediction of the target temperature, the radiometer is calibrated adaptively to the environment and radiometer variations. For this purpose, two reference noise sources (hot and cold) are proposed using matched and mismatched resistors at room temperature. These resistor-based noise sources offer a reliable performance without complex temperature control systems. Furthermore, they can be easily calibrated in real time by periodically measuring the physical temperatures of the resistors. In addition, the logarithmic detector with wide dynamic range is adopted and logarithmically-fitted based on the measurement results instead of linear approximation, which reduces the error caused by the limited dynamic range of resistor-based noise sources. In order to further increase the accuracy, the performance imbalances between ports in the SP3T switch are also taken into account by employing offsets in the radiometer output voltages.

  5. Low noise infrared radiometer%低噪声红外辐射计设计

    Institute of Scientific and Technical Information of China (English)

    胡铁力; 申越; 郭羽; 范纪红; 马世帮; 张玫; 刘瑞星; 谢毅; 辛舟

    2013-01-01

    :In order to solve the calibration of the infrared imager test equipment,a kind of infrared radiometer in which the temperature of interior reference blackbody was equal to the environmental temperature was designed.In order to evaluate this kind of radiometer and give guidance to the infrared radiometer design,a mathematic model for infrared radiometer noise equivalent temperature difference (NETD)was given.The NETD of infrared radiometer was estimated under different electronic bandwidths and spectral wavebands.The results show that when noise equivalent bandwidth is within 1 Hz,NETD of infrared radiometer in mid-wavelength infrared (MWIR) and long wavelength infrared (LWIR) spectral bands is smaller than 0.01℃,which can meet the requirements of the calibration of infrared imager test equipment.%为解决热像仪测试设备校准问题,设计了内部参考黑体温度与环境温度相等的红外辐射计.为评估精密红外辐射计的性能指标,指导精密红外辐射计的设计,建立了红外辐射计NETD(噪声等效温差,Noise equivalent temperature difference)数学模型.估算了在不同电子带宽、光谱波段下红外辐射计的NETD.结果表明,当噪声带宽小于1 Hz时,红外辐射计自身的NETD在MWIR(mid-wavelength infrared)、LWIR(long wavelength infrared)波段均小于0.01℃,能够满足热像仪测试设备校准需要.

  6. Labeling of rabbit neutrophils with (/sup 111/In)oxine

    Energy Technology Data Exchange (ETDEWEB)

    Lane, T.A. (Veterans Administration Medical Center, San Diego, CA (USA). Dept. of Pathology); Bergum, P.W.; Lichter, J.P.; Spragg, R.G. (California Univ., San Diego, La Jolla (USA). School of Medicine)

    1982-06-25

    The successful labeling of rabbit peripheral blood neutrophils with (/sup 111/In)oxine is reported here. Standard techniques for preparation of rabbit neutrophils, while acceptable for maintenance of in vitro function, rendered the neutrophils ineffective for in vivo use after labeling with /sup 111/In. Specifically, rabbit neutrophils were sensitive to the use of hypotonic shock for red cell elimination, centrifugation into a button during preparation, and the presence of oxine during chemotaxis in vitro. Using a carefully modified method of neutrophil preparation and labeling, it was found that /sup 111/In-labeled rabbit neutrophils retained normal in vitro function, including chemotaxis. In addition, using this method, 34% +- 5% of labeled neutrophils were recoverable in peripheral blood 5 min after intravenous injection. The half-life of circulating radiolabeled neutrophils was 5.6 +- 2 h. Continuous external imaging of radiolabeled neutrophils after intravenous injection showed initial lung uptake, followed by rapid clearance of radioactivity in the lungs (50% clearance in 10.5 +- 3.3 min.). Hepatic radioactivity was maximal by 30 min after injection and thereafter slowly declined. Finally, it was found that /sup 111/In-labeled rabbit neutrophils migrated to sites of artificially induced inflammation. These findings indicate that /sup 111/In-labeled rabbit neutrophils, if prepared under optimal conditions, should provide a useful tool for investigating the fate of neutrophils in experimental inflammatory conditions in this animal.

  7. A spaceborne synthetic aperture radiometer simulated by the TUD demonstration model

    DEFF Research Database (Denmark)

    Laursen, Brian; Skou, Niels

    1994-01-01

    The TUD synthetic aperture radiometer demonstration model consists of a 2-channel X-band correlation radiometer with two horn antennas and an antenna mounting structure enabling the horns to be mounted in relevant positions within a certain aperture. The cross correlation of the signals from the ...... samples of the visibility function followed by an image reconstruction procedure which is based on the inverse Fourier transform. The system has been used to simulate a spaceborne instrument (MIRAS) in order to validate the image reconstruction processing...

  8. Two-Look Polarimetric (2LP) Microwave Radiometers for Ocean Vector Wind Retrieval

    Science.gov (United States)

    Wentz, F. J.; Hilburn, K. A.; Meissner, T.; Brown, S. E.

    2014-12-01

    This talk discusses the future utilization of two-look polarimetric (2LP) microwave radiometers for measuring the ocean surface wind vector. Potentially, these 2LP satellite radiometers offer two advantages over conventional scatterometers: unambiguous wind vector retrievals and low-cost. One concept for a 2LP radiometer is being developed by JPL and is called the Compact Ocean Wind Vector Radiometer (COWVR). A space demonstration of COWVR is planned for 2016 timeframe. To explore the potential of 2LP radiometers, we use the 11 years of WindSat observations as a testbed. We only use that portion of the WindSat swath that has both fore and aft observations. WindSat provides fully polarimetric observations (all four Stokes parameters) at 11, 19, and 37 GHz. This represents 12 independent channels for each of the two azimuth directions. A wind vector retrieval algorithm is developed to fully utilize this wide assortment of information. Since this analysis is based on actual observations, it provides a realistic picture of what to expect from future 2LP radiometers. To our knowledge, this is the first time that the combination of WindSat's fore and aft observations has been fully utilized for wind vector retrievals. In our talk we compare the 2LP wind vector retrieval performance with that of single-look polarimetric radiometers (i.e., WindSat standard product) and scatterometers. We provide basic statistics from a triple collocation between winds from WindSat, QuikScat, and NDBC/PMEL ocean moored buoys. The statistics include the standard deviation of the first ranked ambiguity direction, skill rate, and number of ambiguities. All available data from the common period of operation between WindSat and QuikScat (2003-2009) are used. We characterize the wind direction accuracy as a function of wind speed, and show how 2LP retrievals are able to extend the wind vector accuracy to lower wind speeds than previously considered possible for radiometers.

  9. Short-term Prediction and Detection of Dynamic Atmospheric Effects by Microwave Radiometer

    Directory of Open Access Journals (Sweden)

    P. Dvorak

    2012-12-01

    Full Text Available Specific utilization of a microwave radiometer for online monitoring, detection and, especially, prediction of particular dynamic atmospheric effects such as precipitation and cloudiness is proposed in the paper. The ground-based microwave radiometer and meteorological stations were incorporated into the measurement campaign in order to observe actual brightness temperature changes. The characteristics of atmospheric parameters recorded over a period of 14 months were evaluated and new applications for rain forecasting and cloud detection, based on signal variance, were proposed and validated.

  10. Radiometer experiment for the aeroassist flight experiment. [Thermal protection data for Orbital Transfer Vehicle design

    Science.gov (United States)

    Davy, W. C.; Park, C.; Arnold, J. O.; Balakrishnan, A.

    1985-01-01

    A forthcoming NASA flight experiment is described that provides an opportunity to obtain a large base of radiometric data for high-altitude, high-velocity thermochemically nonequilibrated-flow conditions. As a preliminary to the design of a radiometer for this experiment, an approximate method for predicting both equilibrium and nonequilibrium radiative surface fluxes is described. Spectral results for one trajectory state, a velocity of 10 km/sec at an altitude of 85 km, are presented. These results are then used to develop some of the instrument parameters that will be needed for designing of the three genre of radiometers that are proposed for this experiment.

  11. Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection

    Science.gov (United States)

    Sperfeld, Peter; Barton, Bettina; Pape, Sven; Towara, Anna-Lena; Eggers, Jutta; Hopfenmüller, Gabriel

    2014-12-01

    In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected low-pressure mercury and medium-pressure mercury UV lamps. To verify the calibration method and to perform on-site tests, spectral measurements were carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.

  12. Description and Performance of an L-Band Radiometer with Digital Beamforming

    Directory of Open Access Journals (Sweden)

    Juan F. Marchan-Hernandez

    2010-12-01

    Full Text Available This paper presents the description and performance tests of an L-band microwave radiometer with Digital Beamforming (DBF, developed for the Passive Advanced Unit (PAU for ocean monitoring project. PAU is an instrument that combines, in a single receiver and without time multiplexing, a microwave radiometer at L-band (PAU-RAD and a GPS-reflectometer (PAU-GNSS-R. This paper focuses on the PAU‑RAD beamformer’s first results, analyzing the hardware and software required for the developed prototype. Finally, it discusses the first results measured in the Universitat Politècnica de Catalunya (UPC anechoic chamber.

  13. An Optimal Beamforming Algorithm for Phased-Array Antennas Used in Multi-Beam Spaceborne Radiometers

    DEFF Research Database (Denmark)

    Iupikov, O. A.; Ivashina, M. V.; Pontoppidan, K.

    2015-01-01

    Strict requirements for future spaceborne ocean missions using multi-beam radiometers call for new antenna technologies, such as digital beamforming phased arrays. In this paper, we present an optimal beamforming algorithm for phased-array antenna systems designed to operate as focal plane arrays...... (FPA) in push-broom radiometers. This algorithm is formulated as an optimization procedure that maximizes the beam efficiency, while minimizing the side-lobe and cross-polarization power in the area of Earth, subject to a constraint on the beamformer dynamic range. The proposed algorithm is applied...

  14. From Label to Practice

    DEFF Research Database (Denmark)

    Byrkjeflot, Haldor; Strandgaard, Jesper; Svejenova, Silviya

    2013-01-01

    This article examines the process of creation of new Nordic cuisine (NNC) as a culinary innovation, focusing on the main stages, actors, and mechanisms that shaped the new label and its practices and facilitated its diffusion in the region and internationally. Fast-paced diffusion was possible...... because NNC was conceived as an identity movement, triggered by active involvement of entrepreneurial leaders from the culinary profession, high-profile political supporters, legitimating scientists, disseminating media, and interpreting audiences. It was facilitated by three mechanisms: First, the use...... actors and institutions to develop practices associated with the NNC label. Third, organized dissemination allowed the excitement and engagement with the new label to spread quickly....

  15. Capacitive label reader

    Science.gov (United States)

    Arlowe, H. Duane

    1985-01-01

    A capacitive label reader includes an outer ring transmitting portion, an inner ring transmitting portion, and a plurality of insulated receiving portions. A label is the mirror-image of the reader except that identifying portions corresponding to the receiving portions are insulated from only one of two coupling elements. Positive and negative pulses applied, respectively, to the two transmitting rings biased a CMOS shift register positively to either a 1 or 0 condition. The output of the CMOS may be read as an indication of the label.

  16. Production of yeastolates for uniform stable isotope labelling in eukaryotic cell culture.

    NARCIS (Netherlands)

    Egorova-Zachernyuk, T.A.; Bosman, G.J.C.G.M.; Pistorius, A.M.A.; Grip, W.J. de

    2009-01-01

    Preparation of stable isotope-labelled yeastolates opens up ways to establish more cost-effective stable isotope labelling of biomolecules in insect and mammalian cell lines and hence to employ higher eukaryotic cell lines for stable isotope labelling of complex recombinant proteins. Therefore, we e

  17. Food Label and You

    Medline Plus

    Full Text Available ... Sports show highlighting the importance of using the nutrition facts label to control portions, fat, calories and percent daily value. Two studio "sports announcers" describe the "game day" food action of ...

  18. FDA Online Label Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — The drug labels and other drug-specific information on this Web site represent the most recent drug listing information companies have submitted to the Food and Drug...

  19. Figuring Out Food Labels

    Science.gov (United States)

    ... usually appears on the back or side of packaging under the title "Nutrition Facts." It's also displayed in grocery stores near fresh foods, like fruits, vegetables, and fish. The nutrition facts label includes: a column of ...

  20. Food Label and You

    Medline Plus

    Full Text Available ... use the Nutrition Facts Label to make informed food choices. You can view the new video in its ... two sites, comparing serving sizes, ingredients and overall food choices in this "Battle of the Dueling Dinner Parties". ...

  1. Behind the Label "Alcoholic."

    Science.gov (United States)

    Wright, Deborah M.

    1989-01-01

    Relates individual's personal story of her childhood influenced by her parent's alcoholism, her own alcoholism as a young adult, and her experiences with counseling. Asks others not to reject her because of the label "alcoholic." (ABL)

  2. Food Label and You

    Medline Plus

    Full Text Available ... main page content Skip to search Skip to topics menu Skip to common links HHS U.S. Department ... a contestant in food label knowledge. Questions cover topics such as Calories, Serving Size, Servings per Container, ...

  3. Synthesis of F-18 labeled raloxifene derivative

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. C.; Moon, B. S.; Jun, K. S. [KIRAMS, Seoul (Korea, Republic of); Lee, J. H.; Ji, D. Y. [Inha University, Incheon (Korea, Republic of)

    2005-07-01

    Raloxifene, [6-hydroxy-2-(4-hydroxy-phenyl) benzo [b] thiophen-3-yl]-[4-(2-piperidin-1-yl-ethoxy)phenyl] methanone, a tissue-selective estrogen mixed agonist/antagonist, classified as a selective estrogen receptor modulator (SERM), is currently under clinical evaluation for the prevention and treatment of postmenopausal osteoporosis, breast cancer, uterine dysfunction, and other disorders of the female reproductive system. Based on SAR studies of substituted raloxifenes, we synthesized 3 kinds of fluoroalkylated raloxifene derivatives. These compounds show high relative binding affinities (RBA) to the estrogen receptor in vitro (RBA of estradiol = 100%). The RBA values for compounds 1, 2 and 3 are 89, 60, and 45%, respectively, which are all higher than that of raloxifene itself (34%). Among these compounds, we selected to take the best RBA value one and F-18 labeled. Using 2 kinds of labeling method ; 1) Radiolabeling using [{sup 18}F]KF was carried out in anhydrous acetonitrile for 10 min at 120 .deg. C. 2) Radiolabeling using [{sup 18}F]KF was carried out in anhydrous acetonitrile for 15 min at 120 .deg. C in ionic liquid, [bmim][OTf]. Deprotection step added 1N HCl and reacted for 3 min at 120 .deg. C. [{sup 18}F]Fluoroethyl raloxifene derivative obtained 5-23% decay corrected labeling yield by HPLC system (C18 xterra, 10 i, 34% Acetonitrile/0.1 M formate buffer, flow rate: 4 mL/1 min, collection time : 28-29 min) and total time was around 70 min. Fluoroethyl raloxifene derivative has the best RBA value among the other synthesized derivatives and chose it for radiolabeling. [{sup 18}F]Fluoroethyl raloxifene derivative prepared 5-23% decay corrected labeling yield. This preparation is on going for labeling optimizing and preparing of in vitro and in vivo test.

  4. Airborne L-band radiometer mapping of the dome-C area in Antarctica

    DEFF Research Database (Denmark)

    Skou, Niels; Kristensen, Steen Savstrup; Søbjærg, Sten Schmidl

    2015-01-01

    A 350 km × 350 km area near the Concordia station on the high plateau of Dome-C in Antarctica has been mapped by an airborne L-band radiometer system. The area was expected to display a rather uniform brightness temperature (TB) close to the yearly mean temperature-well suited for calibration...

  5. Hybrid PSO-ASVR-based method for data fitting in the calibration of infrared radiometer

    Science.gov (United States)

    Yang, Sen; Li, Chengwei

    2016-06-01

    The present paper describes a hybrid particle swarm optimization-adaptive support vector regression (PSO-ASVR)-based method for data fitting in the calibration of infrared radiometer. The proposed hybrid PSO-ASVR-based method is based on PSO in combination with Adaptive Processing and Support Vector Regression (SVR). The optimization technique involves setting parameters in the ASVR fitting procedure, which significantly improves the fitting accuracy. However, its use in the calibration of infrared radiometer has not yet been widely explored. Bearing this in mind, the PSO-ASVR-based method, which is based on the statistical learning theory, is successfully used here to get the relationship between the radiation of a standard source and the response of an infrared radiometer. Main advantages of this method are the flexible adjustment mechanism in data processing and the optimization mechanism in a kernel parameter setting of SVR. Numerical examples and applications to the calibration of infrared radiometer are performed to verify the performance of PSO-ASVR-based method compared to conventional data fitting methods.

  6. InP HEMT Integrated Circuits for Submillimeter Wave Radiometers in Earth Remote Sensing

    Science.gov (United States)

    Deal, William R.; Chattopadhyay, Goutam

    2012-01-01

    The operating frequency of InP integrated circuits has pushed well into the Submillimeter Wave frequency band, with amplification reported as high as 670 GHz. This paper provides an overview of current performance and potential application of InP HEMT to Submillimeter Wave radiometers for earth remote sensing.

  7. An Optimal Beamforming Algorithm for Phased-Array Antennas Used in Multi-Beam Spaceborne Radiometers

    DEFF Research Database (Denmark)

    Iupikov, O. A.; Ivashina, M. V.; Pontoppidan, K.;

    2015-01-01

    Strict requirements for future spaceborne ocean missions using multi-beam radiometers call for new antenna technologies, such as digital beamforming phased arrays. In this paper, we present an optimal beamforming algorithm for phased-array antenna systems designed to operate as focal plane arrays...

  8. Digital processor breadboard for RFI detection and mitigation in spaceborne radiometers

    DEFF Research Database (Denmark)

    Kristensen, Steen Savstrup; Skou, Niels; Kovanen, Arhippa;

    2014-01-01

    in such systems. Since input to these methods require much more data than traditional radiometer data, and since the downlink capacity for spaceborne systems are limited, RFI detection and mitigation must be implemented on-board thereby maintaining the low downlink data rate. The development of such a system...

  9. Insolation measurements with a portable CuS-CdS radiometer

    Science.gov (United States)

    Windawi, H. M.

    1976-01-01

    Solar radiation measurements were carried out with a portable Cu2S-Cds radiometer. The measurements were found to be accurate to better than 5% (better than 3% when sophisticated metering is employed). Calibration to an Eppley precision pyranometer is discussed.

  10. Automatic acquisition and computation of data from the radiometer dissociation curve analyzer

    NARCIS (Netherlands)

    Maas, A.H.J.; Hamelink, M.L.; Poelgeest, R. van; Zuidema, P.; Kraan, K.J.; Camp, R. van den; Leeuw, R.J.M. de

    1974-01-01

    The whole oxyhemoglobin dissociation curve of blood can be generated using the Radiometer Dissociation Curve Analyzer (model DCA-1), which measures oxygen pressure, oxygen content and pH simultaneously. Thereby the dissociation curve at standard physiological conditions of pH 7.4 and temperature 37°

  11. Microwave Radiometer for Spectral Observations of Mesospheric Carbon Monoxide at 115 GHz Over Kharkiv, Ukraine

    Science.gov (United States)

    Piddyachiy, Valeriy; Shulga, Valerii; Myshenko, Valeriy; Korolev, Alexey; Antyufeyev, Oleksandr; Shulga, Dmytro; Forkman, Peter

    2016-11-01

    We present the results of the development of high sensitivity microwave radiometer designed for observation of the atmospheric carbon monoxide (CO) emission lines at 115 GHz. The receiver of this radiometer has the double-sideband noise temperature of 250 K at a temperature of 10°C. To date, this is the best noise performance for uncooled Schottky diode mixer receiver systems. The designed radiometer was tested during the 2014-2015 period at observations of the carbon monoxide emission lines over Kharkiv, Ukraine (50° N, 36.3° E). These tests have shown the reliability of the receiver system, which allows us in the future to use designed radiometer for continuous monitoring of carbon monoxide. The first observations of the atmospheric carbon monoxide spectral lines over Kharkiv have confirmed seasonal changes in the CO abundance and gave us reasons to assume the spread of the influence of the polar vortex on the state of the atmosphere up to the latitude of 50° N where our measurement system is located.

  12. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-06-02

    This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.

  13. An optimal estimation algorithm to derive Ice and Ocean parameters from AMSR Microwave radiometer observations

    DEFF Research Database (Denmark)

    Pedersen, Leif Toudal; Tonboe, Rasmus T.; Høyer, Jacob

    Global multispectral microwave radiometer measurements have been available for several decades. However, most current sea ice concentration algorithms still only takes advantage of a very limited subset of the available channels. Here we present a method that allows utilization of all available...

  14. An RFI Detection Algorithm for Microwave Radiometers Using Sparse Component Analysis

    Science.gov (United States)

    Mohammed-Tano, Priscilla N.; Korde-Patel, Asmita; Gholian, Armen; Piepmeier, Jeffrey R.; Schoenwald, Adam; Bradley, Damon

    2017-01-01

    Radio Frequency Interference (RFI) is a threat to passive microwave measurements and if undetected, can corrupt science retrievals. The sparse component analysis (SCA) for blind source separation has been investigated to detect RFI in microwave radiometer data. Various techniques using SCA have been simulated to determine detection performance with continuous wave (CW) RFI.

  15. Mapping of the DOME-C area in Antarctica by an airborne L-band radiometer

    DEFF Research Database (Denmark)

    Skou, Niels; Kristensen, Steen Savstrup; Søbjærg, Sten Schmidl

    2014-01-01

    A 350 × 350 km area near the Concordia station on the high plateau of Dome C in Antarctica has been mapped by an airborne L-band radiometer system. The area was expected to display a rather uniform brightness temperature close to the yearly mean temperature — well suited for calibration checks...

  16. Future spaceborne ocean missions using high sensitivity multiple-beam radiometers

    DEFF Research Database (Denmark)

    Skou, Niels; Søbjærg, Sten Schmidl; Kristensen, Steen Savstrup

    2014-01-01

    Design considerations concerning a scanning as well as a push-broom microwave radiometer system are presented. Strict requirements to spatial and radiometric resolution leads to a multiple-beam scanner achieving good sensitivity through integration over many beams, or to a push-broom system where...

  17. SMOS calibration and validation activities with airborne interferometric radiometer HUT-2D during spring 2010

    DEFF Research Database (Denmark)

    Kainulainen, J.; Rautiainen, K.; Sievinen, P.;

    2010-01-01

    In this paper we present calibration and validation activities of European Space Agency’s SMOS mission, which utilize airborne interferomentric L-band radiometer system HUT-2D of the Aalto University. During spring 2010 the instrument was used to measure three SMOS validation target areas, one in...

  18. The Atmospheric Radiation Measurement (ARM program network of microwave radiometers: instrumentation, data, and retrievals

    Directory of Open Access Journals (Sweden)

    M. P. Cadeddu

    2013-04-01

    Full Text Available The Climate Research Facility of the US Department of Energy's Atmospheric Radiation Measurement (ARM Program operates a network of ground-based microwave radiometers. Data and retrievals from these instruments have been available to the scientific community for almost 20 yr. In the past five years the network has been expanded to include a total of 22 microwave radiometers deployed in various locations around the world. The new instruments cover a frequency range between 22 and 197 GHz and are consistently and automatically calibrated. The latest addition to the network is a new generation of three-channel radiometers currently in the early stage of deployment at all ARM sites. The network has been specifically designed to achieve increased accuracy in the retrieval of precipitable water vapor (PWV and cloud liquid water path (LWP with the long-term goal of providing the scientific community with reliable, calibrated radiometric data and retrievals of important geophysical quantities with well-characterized uncertainties. The radiometers provide high-quality, continuous datasets that can be utilized in a wealth of applications and scientific studies. This paper presents an overview of the microwave instrumentation, calibration procedures, data, and retrievals that are available for download from the ARM data archive.

  19. Microwave Radiometer for Spectral Observations of Mesospheric Carbon Monoxide at 115 GHz Over Kharkiv, Ukraine

    Science.gov (United States)

    Piddyachiy, Valeriy; Shulga, Valerii; Myshenko, Valeriy; Korolev, Alexey; Antyufeyev, Oleksandr; Shulga, Dmytro; Forkman, Peter

    2017-03-01

    We present the results of the development of high sensitivity microwave radiometer designed for observation of the atmospheric carbon monoxide (CO) emission lines at 115 GHz. The receiver of this radiometer has the double-sideband noise temperature of 250 K at a temperature of 10°C. To date, this is the best noise performance for uncooled Schottky diode mixer receiver systems. The designed radiometer was tested during the 2014-2015 period at observations of the carbon monoxide emission lines over Kharkiv, Ukraine (50° N, 36.3° E). These tests have shown the reliability of the receiver system, which allows us in the future to use designed radiometer for continuous monitoring of carbon monoxide. The first observations of the atmospheric carbon monoxide spectral lines over Kharkiv have confirmed seasonal changes in the CO abundance and gave us reasons to assume the spread of the influence of the polar vortex on the state of the atmosphere up to the latitude of 50° N where our measurement system is located.

  20. On-board digital RFI and polarimetry processor for future spaceborne radiometer systems

    DEFF Research Database (Denmark)

    Skou, Niels; Kristensen, Steen Savstrup; Ruokokoski, T.

    2012-01-01

    Man-made Radio Frequency Interference (RFI) is an increasingly threatening problem for passive microwave radiometry from space. The problem is presently very evident in L-band data from SMOS, but it is realized that it is already now a problem at other traditional radiometer bands at C, X, and Ku...

  1. Evaluation of brightness temperature from a forward model of ground-based microwave radiometer

    Indian Academy of Sciences (India)

    S Rambabu; J S Pillai; A Agarwal; G Pandithurai

    2014-06-01

    Ground-based microwave radiometers are getting great attention in recent years due to their capability to profile the temperature and humidity at high temporal and vertical resolution in the lower troposphere. The process of retrieving these parameters from the measurements of radiometric brightness temperature () includes the inversion algorithm, which uses the background information from a forward model. In the present study, an algorithm development and evaluation of this forward model for a ground-based microwave radiometer, being developed by Society for Applied Microwave Electronics Engineering and Research (SAMEER) of India, is presented. Initially, the analysis of absorption coefficient and weighting function at different frequencies was made to select the channels. Further the range of variation of for these selected channels for the year 2011, over the two stations Mumbai and Delhi is discussed. Finally the comparison between forward-model simulated s and radiometer measured s at Mahabaleshwar (73.66°E and 17.93°N) is done to evaluate the model. There is good agreement between model simulations and radiometer observations, which suggests that these forward model simulations can be used as background for inversion models for retrieving the temperature and humidity profiles.

  2. Synthesis and labelling of epidepride

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    S-(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-5-iodo-2,3-dimethoxybenzamide (proposed generic name, epidepride) is a very potent dopamine D2 antagonist. It was synthesized by five steps from 3-methoxysalicylic acid. [131I]epidepride was obtained in 97.3% radiochemical yields from the corresponding 5-(tributyltin) derivative using hydrogen peroxide as the oxidant. The aryltin precursor was prepared from non-labelled epidepride by palladium-catalyzed stannylation using bis(tri-n-butyltin) in triethylamine. [131I]epidepride was stable under 4℃, and partition coefficient was 72.3 at pH 7.40. The biodistribution study in rats exihibited high localization in the striatum of the brain with the striatum/cerebellum ratio reaching 237/1 at 320 min postinjection.All these results suggest that[131I]epidepride may be usedd widely as a useful dopamineD2 receptor imaging agent for SPECT.

  3. Surface Wind Vector and Rain Rate Observation Capability of Future Hurricane Imaging Radiometer (HIRAD)

    Science.gov (United States)

    Miller, Timothy; Atlas, Robert; Bailey, M. C.; Black, Peter; El-Nimri, Salem; Hood, Robbie; James, Mark; Johnson, James; Jones, Linwood; Ruf, Christopher; Uhlhorn, Eric

    2009-01-01

    The Hurricane Imaging Radiometer (HIRAD) is the next-generation Stepped Frequency Microwave Radiometer (SFMR), and it will offer the capability of simultaneous wide-swath observations of both extreme ocean surface wind vector and strong precipitation from either aircraft (including UAS) or satellite platforms. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce valid wind observations under hurricane conditions when existing microwave sensors (radiometers or scatterometers) are hindered by precipitation. The SFMR i s a proven aircraft remote sensing system for simultaneously observing extreme ocean surface wind speeds and rain rates, including those of major hurricane intensity. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer technology. The first version of the instrument will be a single polarization system for wind speed and rain rate, with a dual-polarization system to follow for wind vector capability. This sensor will operate over 4-7 GHz (C-band frequencies) where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometers. HIRAD incorporates a unique, technologically advanced array antenna and several other technologies successfully demonstrated by NASA s Instrument Incubator Program. A brassboard (laboratory) version of the instrument has been completed and successfully tested in a test chamber. Development of the aircraft instrument is underway, with flight testing planned for the fall of 2009. Preliminary Observing System Simulation Experiments (OSSEs) show that HIRAD will have a significant positive impact on surface wind analyses as either a new aircraft or satellite sensor. New off-nadir data collected in 2008 by SFMR that affirms the ability of this measurement technique to obtain wind speed data at non-zero incidence angle will

  4. Improved characterization of scenes with a combination of MMW radar and radiometer information

    Science.gov (United States)

    Dill, Stephan; Peichl, Markus; Schreiber, Eric; Anglberger, Harald

    2017-05-01

    For security related applications MMW radar and radiometer systems in remote sensing or stand-off configurations are well established techniques. The range of development stages extends from experimental to commercial systems on the civil and military market. Typical examples are systems for personnel screening at airports for concealed object detection under clothing, enhanced vision or landing aid for helicopter and vehicle based systems for suspicious object or IED detection along roads. Due to the physical principle of active (radar) and passive (radiometer) MMW measurement techniques the appearance of single objects and thus the complete scenario is rather different for radar and radiometer images. A reasonable combination of both measurement techniques could lead to enhanced object information. However, some technical requirements should be taken into account. The imaging geometry for both sensors should be nearly identical, the geometrical resolution and the wavelength should be similar and at best the imaging process should be carried out simultaneously. Therefore theoretical and experimental investigations on a suitable combination of MMW radar and radiometer information have been conducted. First experiments in 2016 have been done with an imaging linescanner based on a cylindrical imaging geometry [1]. It combines a horizontal line scan in azimuth with a linear motion in vertical direction for the second image dimension. The main drawback of the system is the limited number of pixel in vertical dimension at a certain distance. Nevertheless the near range imaging results where promising. Therefore the combination of radar and radiometer sensor was assembled on the DLR wide-field-of-view linescanner ABOSCA which is based on a spherical imaging geometry [2]. A comparison of both imaging systems is discussed. The investigations concentrate on rather basic scenarios with canonical targets like flat plates, spheres, corner reflectors and cylinders. First

  5. Optimization of preparation, labelling and quality control procedures of {sup 99m}Tc-glucarate for the diagnosis of acute myocardial infarction; Otimizacao dos procedimentos de preparacao, marcacao e controle de qualidade do glucarato-{sup 99m}Tc para diagnostico do infarto agudo do miocardio

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Ana Claudia

    2007-07-01

    Cardiovascular diseases account for the main causes of morbidity and mortality among the adult population. Despite the advances of preventive medicine, acute myocardial infarction continues to be frequent and the difficulty of the differential diagnosis is an additional cause of fatal events. Its diagnosis is based on the triad: typical chest pain, alterations in the electrocardiogram and elevation of serum cardiac enzymes. However, many patients evolve without the complete syndrome. Therefore the development of non-invasive assays for the early detection of damaged myocardium is of extreme importance. {sup 99m}Tc-glucarate is a radiopharmaceutical of great interest for application in Nuclear Medicine, because it is referred as a potential marker of necrotic tissues in the early phase of an acute coronary event. This presentation describes the optimization of preparation, lyophilization and labelling as well as quality control procedures of {sup 99m}Tc-glucarate, based on former studies published in the literature. Radiochemical purity was evaluated by the ascending paper chromatography technique. Labelling efficiency as a function respectively of time of reaction, volume and activity of {sup 99m}TcO4- was consistently higher than 97%. The lyophilized kit was stable during 12 months of storage. Biodistribution in healthy Swiss mice showed rapid blood clearance, renal excretion and low uptake by organs adjacent to the heart. Scintigraphic studies of injected Wistar rats confirmed the results of the biodistribution obtained by direct organ counting. Scintigraphies of infarcted female rats proved the sensitivity of the method. (author)

  6. European consumers and nutrition labelling

    DEFF Research Database (Denmark)

    Wills, Josephine M.; Grunert, Klaus G.; Celemín, Laura Fernández

    2009-01-01

    Nutrition labelling of food in Europe is not compulsory, unless a nutrition or health claim is made for the product. The European Commission is proposing mandatory nutrition labelling, even front of pack labelling with nutrition information. Yet, how widespread is nutrition labelling in the EU...

  7. Distance labeling schemes for trees

    DEFF Research Database (Denmark)

    Alstrup, Stephen; Gørtz, Inge Li; Bistrup Halvorsen, Esben;

    2016-01-01

    We consider distance labeling schemes for trees: given a tree with n nodes, label the nodes with binary strings such that, given the labels of any two nodes, one can determine, by looking only at the labels, the distance in the tree between the two nodes. A lower bound by Gavoille et al. [Gavoill...

  8. European consumers and nutrition labelling

    DEFF Research Database (Denmark)

    Wills, Josephine M.; Grunert, Klaus G.; Celemín, Laura Fernández

    2009-01-01

    Nutrition labelling of food in Europe is not compulsory, unless a nutrition or health claim is made for the product. The European Commission is proposing mandatory nutrition labelling, even front of pack labelling with nutrition information. Yet, how widespread is nutrition labelling in the EU...

  9. Enzyme-inhibitor mediated red cell labelling

    Energy Technology Data Exchange (ETDEWEB)

    Ackery, D.M.; Singh, J.; Wyeth, P. (Southampton Univ. (UK). Dept. of Chemistry)

    Red blood cells contain 90% of the body's enzyme carbonic anhydrase to which aromatic sulphonamide inhibitors bind tightly. P-iodo-benzene sulphonamide (PIBS) is a lipophilic inhibitor which would afford rapid cell labelling. Radioiodinated PIBS was prepared, in high yield, by radio ion exchange in the presence of ammonium sulphate. After intravenous injection of /sup 131/I-PIBS the radiolabel was found in the blood pool.

  10. Distance labeling schemes for trees

    DEFF Research Database (Denmark)

    Alstrup, Stephen; Gørtz, Inge Li; Bistrup Halvorsen, Esben

    2016-01-01

    We consider distance labeling schemes for trees: given a tree with n nodes, label the nodes with binary strings such that, given the labels of any two nodes, one can determine, by looking only at the labels, the distance in the tree between the two nodes. A lower bound by Gavoille et al. [Gavoille...... variants such as, for example, small distances in trees [Alstrup et al., SODA, 2003]. We improve the known upper and lower bounds of exact distance labeling by showing that 1/4 log2(n) bits are needed and that 1/2 log2(n) bits are sufficient. We also give (1 + ε)-stretch labeling schemes using Theta......(log(n)) bits for constant ε> 0. (1 + ε)-stretch labeling schemes with polylogarithmic label size have previously been established for doubling dimension graphs by Talwar [Talwar, STOC, 2004]. In addition, we present matching upper and lower bounds for distance labeling for caterpillars, showing that labels...

  11. Precipitation Estimation Using Combined Radar/Radiometer Measurements Within the GPM Framework

    Science.gov (United States)

    Hou, Arthur

    2012-01-01

    The Global Precipitation Measurement (GPM) Mission is an international satellite mission specifically designed to unify and advance precipitation measurements from a constellation of research and operational microwave sensors. The GPM mission centers upon the deployment of a Core Observatory in a 65o non-Sun-synchronous orbit to serve as a physics observatory and a transfer standard for intersatellite calibration of constellation radiometers. The GPM Core Observatory will carry a Ku/Ka-band Dual-frequency Precipitation Radar (DPR) and a conical-scanning multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The DPR will be the first dual-frequency radar in space to provide not only measurements of 3-D precipitation structures but also quantitative information on microphysical properties of precipitating particles needed for improving precipitation retrievals from microwave sensors. The DPR and GMI measurements will together provide a database that relates vertical hydrometeor profiles to multi-frequency microwave radiances over a variety of environmental conditions across the globe. This combined database will be used as a common transfer standard for improving the accuracy and consistency of precipitation retrievals from all constellation radiometers. For global coverage, GPM relies on existing satellite programs and new mission opportunities from a consortium of partners through bilateral agreements with either NASA or JAXA. Each constellation member may have its unique scientific or operational objectives but contributes microwave observations to GPM for the generation and dissemination of unified global precipitation data products. In addition to the DPR and GMI on the Core Observatory, the baseline GPM constellation consists of the following sensors: (1) Special Sensor Microwave Imager/Sounder (SSMIS) instruments on the U.S. Defense Meteorological Satellite Program (DMSP) satellites, (2) the Advanced Microwave Scanning Radiometer-2 (AMSR-2) on the GCOM-W1

  12. Semantic Role Labeling

    CERN Document Server

    Palmer, Martha; Xue, Nianwen

    2011-01-01

    This book is aimed at providing an overview of several aspects of semantic role labeling. Chapter 1 begins with linguistic background on the definition of semantic roles and the controversies surrounding them. Chapter 2 describes how the theories have led to structured lexicons such as FrameNet, VerbNet and the PropBank Frame Files that in turn provide the basis for large scale semantic annotation of corpora. This data has facilitated the development of automatic semantic role labeling systems based on supervised machine learning techniques. Chapter 3 presents the general principles of applyin

  13. Labeling of Patient Specimens

    Science.gov (United States)

    2011-01-26

    noted during the event that the actu.al number of near miss incidmts reported monthly was low due to laboratory personnel performing rounds each...specimens never leaves label and if moved it is labeled), All orders in system and all near misses and errors reported to patient safety Purchase/Install...Meeting 14 Aug 09, 1400 in lab break room thru out Develop TICK sheet to track near misses .JDI Ms. Clark Clinics will provide toPS 1st working day of

  14. Quantitative proteomics using reductive dimethylation for stable isotope labeling.

    Science.gov (United States)

    Tolonen, Andrew C; Haas, Wilhelm

    2014-07-01

    Stable isotope labeling of peptides by reductive dimethylation (ReDi labeling) is a method to accurately quantify protein expression differences between samples using mass spectrometry. ReDi labeling is performed using either regular (light) or deuterated (heavy) forms of formaldehyde and sodium cyanoborohydride to add two methyl groups to each free amine. Here we demonstrate a robust protocol for ReDi labeling and quantitative comparison of complex protein mixtures. Protein samples for comparison are digested into peptides, labeled to carry either light or heavy methyl tags, mixed, and co-analyzed by LC-MS/MS. Relative protein abundances are quantified by comparing the ion chromatogram peak areas of heavy and light labeled versions of the constituent peptide extracted from the full MS spectra. The method described here includes sample preparation by reversed-phase solid phase extraction, on-column ReDi labeling of peptides, peptide fractionation by basic pH reversed-phase (BPRP) chromatography, and StageTip peptide purification. We discuss advantages and limitations of ReDi labeling with respect to other methods for stable isotope incorporation. We highlight novel applications using ReDi labeling as a fast, inexpensive, and accurate method to compare protein abundances in nearly any type of sample.

  15. R-phycoerythrin标记抗猪瘟病毒荧光抗体的制备及其与FITC标记荧光抗体检测的比较研究%Preparation of R-phycoerythrin-labeled Anti-CSFV Fluorescence Antibody and Comparison with FITC-labeled Anti-CSFV Fluorescence Antibody

    Institute of Scientific and Technical Information of China (English)

    赵守山; 颜世敢; 朱丽萍; 崔道实

    2011-01-01

    用摩尔比100∶1的化学交联剂SPDP分别将RPE、抗猪瘟病毒抗体衍生,两种衍生物再以摩尔比1∶1液相交联,HPLC纯化制备出RPE标记的抗猪瘟病毒荧光抗体.对制备的荧光抗体从荧光特性、抗体活性、稳定性及纯度等方面进行鉴定.以澳化氰活化的琼脂糖微球为固相载体,采用固相免疫荧光检测法,以制备的RPE、FITC分别标记的荧光抗体检测猪瘟病毒细胞毒.结果表明,RPE标记的荧光抗体检测阳性微球在蓝绿光激发下发射桔黄色荧光,荧光明亮,无本底光干扰,检测灵敏度高达2.67×10-6mg·mL-1,是FITC标记的荧光抗体检测灵敏度的10倍.RPE可替代FTTC或与FITC等荧光染料一起用于多色荧光免疫检测.%R-phycoerythrin from Polysiphonia uneolata was an excellent fluorescent dye with orange-yellowed bright fluorescence. Both of them have the same absorption peak, but the maximum fluorescence emission of R-phycoerythrin was SO nm larger than that of FITC. Purified R-phycoerythrin and multiple-clone antibody of Classical Swine Fever virus was modified by SPDP at the molar ratio of 100 to 1, and then conjugated with each other at the molar ratio of 1 to 1, subsequently purified with HPLC. R-phycoerythrin-labeled antibody was applied to detect CSFV by use of solid-phase immunofluorescence detection method on a CNBr-activated sepharose spheres. Hie system showed orange-yellowed emission fluorescence with high sensitivity and high specificity, the detection sensitivity attained 2.67 x 10"6 mg ? mL~', which was ten times more sensitive than that of FITC-labeled antibody. R-phycoerythrin can substitute for FITC or be used in multiple immunofluorescence detection combined with other dyes.

  16. Ice hydrometeor profile retrieval algorithm for high frequency microwave radiometers: application to the CoSSIR instrument during TC4

    Directory of Open Access Journals (Sweden)

    K. F. Evans

    2012-04-01

    Full Text Available A Bayesian algorithm to retrieve profiles of cloud ice water content (IWC, ice particle size (Dme, and relative humidity from millimeter-wave/submillimeter-wave radiometers is presented. The first part of the algorithm prepares an a priori file with cumulative distribution functions (CDFs and empirical orthogonal functions (EOFs of profiles of temperature, relative humidity, three ice particle parameters (IWC, Dme, distribution width, and two liquid cloud parameters. The a priori CDFs and EOFs are derived from CloudSat radar reflectivity profiles and associated ECMWF temperature and relative humidity profiles combined with three cloud microphysical probability distributions obtained from in situ cloud probes. The second part of the algorithm uses the CDF/EOF file to perform a Bayesian retrieval with a hybrid technique that uses Monte Carlo integration (MCI or, when too few MCI cases match the observations, uses optimization to maximize the posterior probability function. The very computationally intensive Markov chain Monte Carlo (MCMC method also may be chosen as a solution method. The radiative transfer model assumes mixtures of several shapes of randomly oriented ice particles, and here random aggregates of hexagonal plates, spheres, and dendrites are used for tropical convection. A new physical model of stochastic dendritic snowflake aggregation is developed. The retrieval algorithm is applied to data from the Compact Scanning Submillimeter-wave Imaging Radiometer (CoSSIR flown on the ER-2 aircraft during the Tropical Composition, Cloud and Climate Coupling (TC4 experiment in 2007. Example retrievals with error bars are shown for nadir profiles of IWC, Dme, and relative humidity, and nadir and conical scan swath retrievals of ice water path and average Dme. The ice cloud retrievals are evaluated by retrieving integrated 94 GHz backscattering from CoSSIR for comparison

  17. Ice hydrometeor profile retrieval algorithm for high frequency microwave radiometers: application to the CoSSIR instrument during TC4

    Science.gov (United States)

    Evans, K. F.; Wang, J. R.; O'C Starr, D.; Heymsfield, G.; Li, L.; Tian, L.; Lawson, R. P.; Heymsfield, A. J.; Bansemer, A.

    2012-04-01

    A Bayesian algorithm to retrieve profiles of cloud ice water content (IWC), ice particle size (Dme), and relative humidity from millimeter-wave/submillimeter-wave radiometers is presented. The first part of the algorithm prepares an a priori file with cumulative distribution functions (CDFs) and empirical orthogonal functions (EOFs) of profiles of temperature, relative humidity, three ice particle parameters (IWC, Dme, distribution width), and two liquid cloud parameters. The a priori CDFs and EOFs are derived from CloudSat radar reflectivity profiles and associated ECMWF temperature and relative humidity profiles combined with three cloud microphysical probability distributions obtained from in situ cloud probes. The second part of the algorithm uses the CDF/EOF file to perform a Bayesian retrieval with a hybrid technique that uses Monte Carlo integration (MCI) or, when too few MCI cases match the observations, uses optimization to maximize the posterior probability function. The very computationally intensive Markov chain Monte Carlo (MCMC) method also may be chosen as a solution method. The radiative transfer model assumes mixtures of several shapes of randomly oriented ice particles, and here random aggregates of hexagonal plates, spheres, and dendrites are used for tropical convection. A new physical model of stochastic dendritic snowflake aggregation is developed. The retrieval algorithm is applied to data from the Compact Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) flown on the ER-2 aircraft during the Tropical Composition, Cloud and Climate Coupling (TC4) experiment in 2007. Example retrievals with error bars are shown for nadir profiles of IWC, Dme, and relative humidity, and nadir and conical scan swath retrievals of ice water path and average Dme. The ice cloud retrievals are evaluated by retrieving integrated 94 GHz backscattering from CoSSIR for comparison with the Cloud Radar System (CRS) flown on the same aircraft. The rms difference in

  18. 禽偏肺病毒地高辛核酸探针的制备与应用%Preparation and application of digoxigenin-labeled nucleic acid probe for detection of avian metapneumovirus

    Institute of Scientific and Technical Information of China (English)

    陈琳; 刁有祥; 鞠小军; 慕榕; 郑新颖; 刘霞; 孙静; 吴海洋

    2012-01-01

    根据GenBank中已经发表的B亚型禽偏肺病毒F基因的保守序列设计并合成1对引物,利用RT—PCR扩增出1条与目的片段大小一致的725bp基因片段,回收、纯化PCR产物,用地高辛标记,制备出地高辛标记的aMPV核酸探针。特异性检测结果表明,该探针能与aMPV核酸发生特异性杂交,而与H9N2亚型AIV、NDV、IBV、ORT和E.coil的核酸杂交反应均为阴性;敏感性检测结果表明,该探针对aMPV的最低检出量为5Pg。应用制备的探针对山东省不同地区的605份商品肉鸡和122份商品肉鸭进行了核酸探针检测,阳性检出率分别为36.59%和34.51%。本试验制备的aMPV地高辛探针特异性强、敏感性好,对样品的检测结果表明山东省部分地区的商品肉鸡、肉鸭中普遍存在aMPV感染。%According to the genomic sequences of F gene of avian metapneumovirus (aMPV) published in GenBank,a pair of primers was designed for amplifying the 725 hp fragment in RT-PCR experiments. Then the PCR product was labeled with DIG as cDNA probe for detection of aMPV. The hybridization assay of specificity showed that the DNA of aMPV were positive,but other nucleotide extracted from AIV, NDV, IBV, ORT and E. coil were negative. The sensitivity test showed that as low as 5 pg of aMPV's DNA could be detected by DIG-labeled probe. The samples of 605 broilers and 122 ducks were collected from flocks in Shandong province,then dot blot hybridization was used to detect avian metapneumovirus,The results show that the detection rates of the two kinds of brids are 36.59% and 34.51% ,respectively. The results showed that the probe could be used in the detection of avian metapneumovirus. This investigation also shows that aMPV was presence in China and the infection is common in broilers and ducks on some farms in Shandong province.

  19. Labelled Execution Systems

    Science.gov (United States)

    2012-05-07

    This is most starkly evident in the classical example used to demonstrate that, in the case of infinitely branching systems, a transfinite number of... transfinite number of iterations to converge, what can be shown to fail by appropriately embedding the labelled transition systems of [46, prop. 10.5

  20. Waisda?: video labeling game

    NARCIS (Netherlands)

    Hildebrand, M.; Brinkerink, M.; Gligorov, R.; Steenbergen, M. van; Huijkman, J.; Oomen, J.

    2013-01-01

    The Waisda? video labeling game is a crowsourcing tool to collect user-generated metadata for video clips. It follows the paradigm of games-with-a-purpose, where two or more users play against each other by entering tags that describe the content of the video. Players score points by entering the sa

  1. Multi-label

    Directory of Open Access Journals (Sweden)

    Neda Abdelhamid

    2015-01-01

    Full Text Available Generating multi-label rules in associative classification (AC from single label data sets is considered a challenging task making the number of existing algorithms for this task rare. Current AC algorithms produce only the largest frequency class connected with a rule in the training data set and discard all other classes even though these classes have data representation with the rule’s body. In this paper, we deal with the above problem by proposing an AC algorithm called Enhanced Multi-label Classifiers based Associative Classification (eMCAC. This algorithm discovers rules associated with a set of classes from single label data that other current AC algorithms are unable to induce. Furthermore, eMCAC minimises the number of extracted rules using a classifier building method. The proposed algorithm has been tested on a real world application data set related to website phishing and the results reveal that eMCAC’s accuracy is highly competitive if contrasted with other known AC and classic classification algorithms in data mining. Lastly, the experimental results show that our algorithm is able to derive new rules from the phishing data sets that end-users can exploit in decision making.

  2. Food Label and You

    Medline Plus

    Full Text Available ... Label and You — Video Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print NOTE: FDA has issued final changes ... choices. You can view the new video in its entirety or select on any of the individual ...

  3. CAROLS: A New Airborne L-Band Radiometer for Ocean Surface and Land Observations

    DEFF Research Database (Denmark)

    Zribi, Mehrez; Parde, Mickael; Boutin, Jacquline

    2011-01-01

    on board a dedicated French ATR42 research aircraft, in conjunction with other airborne instruments (C-Band scatterometer-STORM, the GOLD-RTR GPS system, the infrared CIMEL radiometer and a visible wavelength camera). Following initial laboratory qualifications, three airborne campaigns involving 21...... flights were carried out over South West France, the Valencia site and the Bay of Biscay (Atlantic Ocean) in 2007, 2008 and 2009, in coordination with in situ field campaigns. In order to validate the CAROLS data, various aircraft flight patterns and maneuvers were implemented, including straight...... horizontal flights, circular flights, wing and nose wags over the ocean. Analysis of the first two campaigns in 2007 and 2008 leads us to improve the CAROLS radiometer regarding isolation between channels and filter bandwidth. After implementation of these improvements, results show that the instrument...

  4. Analysis of RFI Identification and Mitigation in CAROLS Radiometer Data Using a Hardware Spectrum Analyser

    Directory of Open Access Journals (Sweden)

    Christophe Caudoux

    2011-03-01

    Full Text Available A method to identify and mitigate radio frequency interference (RFI in microwave radiometry based on the use of a spectrum analyzer has been developed. This method has been tested with CAROLS L-band airborne radiometer data that are strongly corrupted by RFI. RFI is a major limiting factor in passive microwave remote sensing interpretation. Although the 1.400–1.427 GHz bandwidth is protected, RFI sources close to these frequencies are still capable of corrupting radiometric measurements. In order to reduce the detrimental effects of RFI on brightness temperature measurements, a new spectrum analyzer has been added to the CAROLS radiometer system. A post processing algorithm is proposed, based on selective filters within the useful bandwidth divided into sub-bands. Two discriminant analyses based on the computation of kurtosis and Euclidian distances have been compared evaluated and validated in order to accurately separate the RF interference from natural signals.

  5. Development of a new radiometer for the thermodynamic measurement of high temperature fixed points

    Energy Technology Data Exchange (ETDEWEB)

    Dury, M. R.; Goodman, T. M.; Lowe, D. H.; Machin, G.; Woolliams, E. R. [National Physical Laboratory, Teddington (United Kingdom)

    2013-09-11

    The National Physical Laboratory (NPL) has developed a new radiometer to measure the thermodynamic melting point temperatures of high temperature fixed points with ultra-low uncertainties. In comparison with the NPL's Absolute Radiation Thermometer (ART), the 'THermodynamic Optical Radiometer' (THOR) is more portable and compact, with a much lower size-of-source effect and improved performance in other parameters such as temperature sensitivity. It has been designed for calibration as a whole instrument via the radiance method, removing the need to calibrate the individual subcomponents, as required by ART, and thereby reducing uncertainties. In addition, the calibration approach has been improved through a new integrating sphere that has been designed to have greater uniformity.

  6. Fundamentals of absolute pyroheliometry and objective characterization. [using a narrow field of view radiometer

    Science.gov (United States)

    Crommelynck, D. A.

    1982-01-01

    The radiometric methodology in use with a narrow field of view radiometer for observation of the solar constant is described. The radiation output of the Sun is assumed to be constant, enabling the monitoring of the solar source by an accurately pointed radiometer, and the Sun's output is measured as a function of time. The instrument is described, its angular response considered, and principles for absolute radiometric measurement presented. Active modes of operation are analyzed, taking into consideration instrumental perturbations and sensor efficiency, heating wire effect, cavity sensor efficiency, thermal effects on the surface of the sensitive area, the effect of the field of view limiting system, and the frequency response of the heat flux detector and absolute radiometric system. Performance of absolute measurements with relatively high accuracy is demonstrated.

  7. Design and first plasma measurements of the ITER-ECE prototype radiometer

    Science.gov (United States)

    Austin, M. E.; Brookman, M. W.; Rowan, W. L.; Danani, S.; Bryerton, E. W.; Dougherty, P.

    2016-11-01

    On ITER, second harmonic optically thick electron cyclotron emission (ECE) in the range of 220-340 GHz will supply the electron temperature (Te). To investigate the requirements and capabilities prescribed for the ITER system, a prototype radiometer covering this frequency range has been developed by Virginia Diodes, Inc. The first plasma measurements with this instrument have been carried out on the DIII-D tokamak, with lab bench tests and measurements of third through fifth harmonic ECE from high Te plasmas. At DIII-D the instrument shares the transmission line of the Michelson interferometer and can simultaneously acquire data. Comparison of the ECE radiation temperature from the absolutely calibrated Michelson and the prototype receiver shows that the ITER radiometer provides accurate measurements of the millimeter radiation across the instrument band.

  8. Characteristic of a Digital Correlation Radiometer Back End with Finite Wordlength

    Science.gov (United States)

    Biswas, Sayak K.; Hyde, David W.; James, Mark W.; Cecil, Daniel J.

    2017-01-01

    The performance characteristic of a digital correlation radiometer signal processing back end (DBE) is analyzed using a simulator. The particular design studied here corresponds to the airborne Hurricane Imaging radiometer which was jointly developed by the NASA Marshall Space Flight Center, University of Michigan, University of Central Florida and NOAA. Laboratory and flight test data is found to be in accord with the simulation results. Overall design seems to be optimum for the typical input signal dynamic range. It was found that the performance of the digital kurtosis could be improved by lowering the DBE input power level. An unusual scaling between digital correlation channels observed in the instrument data is confirmed to be a DBE characteristic.

  9. Health Labeling, and Consumption- Understanding Determinants To Health Label Use.

    OpenAIRE

    Hoyer, David; Dossing, Jens; Zhuravleva, Anna

    2013-01-01

    Consumer behavior was explored through the understanding, and use of health labeling. Government and business forces were discovered to influence the ability of consumers to use health labels for improved health and life expectancy, and reduce the negative health care costs of food related diseases. Our survey results were compared to other papers and experiments in the field of consumption and labeling. We discovered high usage of labels, especially nutrition information, and a desire for fr...

  10. Development of Breakthrough Technology for Spaceflight Microwave Radiometers? RFI Noise Detection and Mitigation Based on the HHT2 Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave active/passive radiometer is the premier instrument for remote sensing of Earth. However, it carries the price of non-linear response by its horn-receiver...

  11. A 110 GHz ozone radiometer with a cryogenic planar Schottky mixer

    Energy Technology Data Exchange (ETDEWEB)

    Koistinen, O.P.; Valmu, H.T.; Raeisaenen, A. (Helsinki Univ. of Technology, Espoo (Finland)); Vdovin, V.F.; Dryagin, Y.A.; Lapkin, I.V. (Russian Academy of Science, Nizhny-Novgorod (Russian Federation))

    1993-12-01

    A total power radiometer is presented for monitoring of the stratospheric ozone spectral line at 110 GHz. Special features such as a cooled planar Schottky mixer as the front end and efficient reduction of standing waves in the quasi-optics, are discussed in detail. The noise temperature of the receiver is 530 K (SSB), and the total bandwidth of the receiver is 1 GHz. A dual acousto-optical spectrometer is used for the signal detection.

  12. Sea surface temperature for climate from the along-track scanning radiometers

    OpenAIRE

    Embury, Owen

    2014-01-01

    This thesis describes the construction of a sea surface temperature (SST) dataset from Along-Track Scanning Radiometer (ATSR) observations suitable for climate applications. The algorithms presented here are now used at ESA for reprocessing of historical ATSR data and will be the basis of the retrieval used on the forthcoming SLSTR instrument on ESA’s Sentinel-3 satellite. In order to ensure independence of ATSR SSTs from in situ measurements, the retrieval uses physics-based m...

  13. A General Analysis of the Impact of Digitization in Microwave Correlation Radiometers

    Directory of Open Access Journals (Sweden)

    Hyuk Park

    2011-06-01

    Full Text Available This study provides a general framework to analyze the effects on correlation radiometers of a generic quantization scheme and sampling process. It reviews, unifies and expands several previous works that focused on these effects separately. In addition, it provides a general theoretical background that allows analyzing any digitization scheme including any number of quantization levels, irregular quantization steps, gain compression, clipping, jitter and skew effects of the sampling period.

  14. Parabola directional field radiometer for aiding in space sensor data interpretations

    Science.gov (United States)

    Deering, Donald W.

    1988-01-01

    A unique field radiometer, called the Parabola, was developed to accurately measure the multidirectional incoming and outgoing spectral radiances for a variety of earth surface types; these range from rangeland vegetation to ice and snow. It is found that bidirectional reflectance characteristics are not constant for a given type of vegetation. There can be substantial changes in the anisotropic expression with changes in the solar zenith angle and vegetation conditions.

  15. L-Band Radiometers Measuring Salinity From Space: Atmospheric Propagation Effects

    DEFF Research Database (Denmark)

    Skou, Niels; Hofman-Bang, Dorthe

    2005-01-01

    Microwave radiometers can measure sea surface salinity from space using L-band frequencies around 1.4 GHz. However, requirements to the accuracy of the measurements, in order to be satisfactory for the user, are so stringent that the influence of the intervening atmosphere cannot be neglected....... The present paper will describe and quantify the effect of losses in the atmosphere caused by oxygen, water vapor, clouds, and rain, and indicate possible correction actions to be taken....

  16. Technique for Radiometer and Antenna Array Calibration with Two Antenna Noise Diodes

    Science.gov (United States)

    Srinivasan, Karthik; Limaye, Ashutosh; Laymon, Charles; Meyer, Paul

    2011-01-01

    This paper presents a new technique to calibrate a microwave radiometer and phased array antenna system. This calibration technique uses a radiated noise source in addition to an injected noise sources for calibration. The plane of reference for this calibration technique is the face of the antenna and therefore can effectively calibration the gain fluctuations in the active phased array antennas. This paper gives the mathematical formulation for the technique and discusses the improvements brought by the method over the existing calibration techniques.

  17. On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

    Science.gov (United States)

    Brown, Shannon T.; Desai, Shailen; Lu, Wenwen; Tanner, Alan B.

    2007-01-01

    Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

  18. Mesospheric CO above Troll station, Antarctica observed by a ground based microwave radiometer

    Directory of Open Access Journals (Sweden)

    C. Straub

    2013-01-01

    Full Text Available This paper presents mesospheric carbon monoxide (CO data acquired by the ground-based microwave radiometer of the British Antarctic Survey (BAS radiometer stationed at Troll station in Antarctica (72° S, 2.5° E, 1270 a.m.s.l.. The data set covers the period from February 2008 to January 2010, however, due to very low CO concentrations below approximately 80 km altitude in summer, profiles can only be retrieved during Antarctic winter. CO is measured for approximately 2 h each day and profiles are retrieved approximately every half hour. The retrieved profiles, covering the pressure range from 1 to 0.01 hPa (approximately 48 to 80 km, are compared to measurements from Aura/MLS and SD-WACCM. This intercomparison reveals a low bias of 0.5 to 1 ppmv at 0.1 hPa (approximately 64 km and 2.5 to 3.5 ppmv at 0.01 hPa (approximately 80 km of the BAS microwave radiometer compared to both reference datasets. One explanation for this low bias could be the known high bias of MLS which is in the same order of magnitude. The ground based radiometer shows high and significant correlation (coefficients higher than 0.9/0.65 compared to MLS/SD-WACCM at all altitudes compared with both reference datasets. doi:10.5285/DE3E2092-406D-47A9-9205-3971A8DFB4A9

  19. Mesospheric CO above Troll station, Antarctica observed by a ground based microwave radiometer

    Directory of Open Access Journals (Sweden)

    C. Straub

    2013-06-01

    Full Text Available This paper presents mesospheric carbon monoxide (CO data acquired by the ground-based microwave radiometer of the British Antarctic Survey (BAS radiometer stationed at Troll station in Antarctica (72° S, 2.5° E, 1270 m a.s.l.. The dataset covers the period from February 2008 to January 2010, however, due to very low CO concentrations below approximately 80 km altitude in summer, profiles are only presented during the Antarctic winter. CO is measured for approximately 2 h each day and profiles are retrieved approximately every half hour. The retrieved profiles, covering the pressure range from 1 to 0.01 hPa (approximately 48 to 80 km, are compared to measurements from Microwave Limb Sounder on the Aura satellite (Aura/MLS and Whole Atmosphere Community Climate Model with Specified Dynamics (SD-WACCM. This intercomparison reveals a low bias of 0.5 to 1 ppmv at 0.1 hPa (approximately 64 km and 2.5 to 3.5 ppmv at 0.01 hPa (approximately 80 km of the BAS microwave radiometer compared to both reference datasets. One explanation for this low bias could be the known high bias of MLS which is on the same order of magnitude. The ground based radiometer shows high and significant correlation (coefficients higher than 0.9/0.7 compared to MLS/SD-WACCM at all altitudes compared with both reference datasets. The dataset can be accessed under http://dx.doi.org/10/mhq.

  20. Absolute intensity calibration of the 32-channel heterodyne radiometer on experimental advanced superconducting tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.; Zhao, H. L.; Liu, Y., E-mail: liuyong@ipp.ac.cn; Li, E. Z.; Han, X.; Ti, A.; Hu, L. Q.; Zhang, X. D. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Domier, C. W.; Luhmann, N. C. [Department of Electrical and Computer Engineering, University of California at Davis, Davis, California 95616 (United States)

    2014-09-15

    This paper presents the results of the in situ absolute intensity calibration for the 32-channel heterodyne radiometer on the experimental advanced superconducting tokamak. The hot/cold load method is adopted, and the coherent averaging technique is employed to improve the signal to noise ratio. Measured spectra and electron temperature profiles are compared with those from an independent calibrated Michelson interferometer, and there is a relatively good agreement between the results from the two different systems.

  1. The Cubesat Radiometer Radio Frequency Interference Technology Validation (CubeRRT) Mission

    Science.gov (United States)

    Misra, S.; Johnson, J. T.; Ball, C.; Chen, C. C.; Smith, G.; McKelvey, C.; Andrews, M.; O'Brien, A.; Kocz, J.; Jarnot, R.; Brown, S. T.; Piepmeier, J. R.; Lucey, J.; Miles, L. R.; Bradley, D.; Mohammed, P.

    2016-12-01

    Passive microwave measurements made below 40GHz have experienced increased amounts of man-made radio frequency interference (RFI) over the past couple of decades. Such RFI has had a degenerative impact on various important geophysical retrievals such as soil-moisture, sea-surface salinity, atmospheric water vapor, precipitation etc. The commercial demand for spectrum allocation has increased over the past couple of years - infringing on frequencies traditionally reserved for scientific uses such as Earth observation at passive microwave frequencies. With the current trend in shared spectrum allocations, future microwave radiometers will have to co-exist with terrestrial RFI sources. The CubeSat Radiometer Radio Frequency Interference Technology Validation (CubeRRT) mission is developing a 6U Cubesat system to demonstrate RFI detection and filtering technologies for future microwave radiometer remote sensing missions. CubeRRT will operate between 6-40GHz, and demonstrate on-board real-time RFI detection on Earth brightness temperatures tuned over 1GHz steps. The expected launch date for CubeRRT is early 2018. Digital subsystems for higher frequency microwave radiometry require a larger bandwidth, as well as more processing power and on-board operation capabilities for RFI filtering. Real-time and on-board RFI filtering technology development is critical for future missions to allow manageable downlink data volumes. The enabling CubeRRT technology is a digital FPGA-based spectrometer with a bandwidth of 1 GHz that is capable of implementing advanced RFI filtering algorithms that use the kurtosis and cross-frequency RFI detection methods in real-time on board the spacecraft. The CubeRRT payload consists of 3 subsystems: a wideband helical antenna, a tunable analog radiometer subsystem, and a digital backend. The following presentation will present an overview of the system and results from the latest integration and test.

  2. Characterisation and improvement of j(O1D) filter radiometers

    Science.gov (United States)

    Bohn, Birger; Heard, Dwayne E.; Mihalopoulos, Nikolaos; Plass-Dülmer, Christian; Schmitt, Rainer; Whalley, Lisa K.

    2016-07-01

    Atmospheric O3 → O(1D) photolysis frequencies j(O1D) are crucial parameters for atmospheric photochemistry because of their importance for primary OH formation. Filter radiometers have been used for many years for in situ field measurements of j(O1D). Typically the relationship between the output of the instruments and j(O1D) is non-linear because of changes in the shape of the solar spectrum dependent on solar zenith angles and total ozone columns. These non-linearities can be compensated for by a correction method based on laboratory measurements of the spectral sensitivity of the filter radiometer and simulated solar actinic flux density spectra. Although this correction is routinely applied, the results of a previous field comparison study of several filter radiometers revealed that some corrections were inadequate. In this work the spectral characterisations of seven instruments were revised, and the correction procedures were updated and harmonised considering recent recommendations of absorption cross sections and quantum yields of the photolysis process O3 → O(1D). Previous inconsistencies were largely removed using these procedures. In addition, optical interference filters were replaced to improve the spectral properties of the instruments. Successive determinations of spectral sensitivities and field comparisons of the modified instruments with a spectroradiometer reference confirmed the improved performance. Overall, filter radiometers remain a low-maintenance alternative of spectroradiometers for accurate measurements of j(O1D) provided their spectral properties are known and potential drifts in sensitivities are monitored by regular calibrations with standard lamps or reference instruments.

  3. Atmospheric water distribution in cyclones as seen with Scanning Multichannel Microwave Radiometers (SMMR)

    Science.gov (United States)

    Katsaros, K. B.; Mcmurdie, L. A.

    1983-01-01

    Passive microwave measurements are used to study the distribution of atmospheric water in midlatitude cyclones. The integrated water vapor, integrated liquid water, and rainfall rate are deduced from the brightness temperatures at microwave frequencies measured by the Scanning Multichannel Microwave Radiometer (SMRR) flown on both the Seasat and Nimbus 7 satellites. The practical application of locating fronts by the cyclone moisture pattern over oceans is shown, and the relationship between the quantity of coastal rainfall and atmospheric water content is explored.

  4. Weight estimates and packaging techniques for the microwave radiometer spacecraft. [shuttle compatible design

    Science.gov (United States)

    Jensen, J. K.; Wright, R. L.

    1981-01-01

    Estimates of total spacecraft weight and packaging options were made for three conceptual designs of a microwave radiometer spacecraft. Erectable structures were found to be slightly lighter than deployable structures but could be packaged in one-tenth the volume. The tension rim concept, an unconventional design approach, was found to be the lightest and transportable to orbit in the least number of shuttle flights.

  5. F-18 labeled 3-fluorodiazepam

    Energy Technology Data Exchange (ETDEWEB)

    Luxen, A.; Barrio, J.R.; Bida, G.T.; Satyamurthy, N.; Phelps, M.E.

    1985-05-01

    3-Fluorodiazepam is a new and potent antianxiety agent with prolonged action. The authors found that molecular fluorine (0.5% in Ne) reacts cleanly with diazepam in freon or chloroform at room temperature to produce 3-fluorodiazepam in good yields. Successful syntheses have employed 2:1 to 5:1 molar ratios diazepam: fluorine to minimize the formation of byproducts. (/sup 18/F) 3-Fluorodiazepam, a potential candidate for PET studies, (specific activity 3-5 Ci/mmol) has been synthesized from /sup 18/F-F/sub 2/ using the same procedure, followed by column chromatographic purification (Silicagel, dichloromethane: ethyl acetate, 5:1) with a radiochemical yield of 12-20% (50% maximum) and a chemical and radiochemical purity >99% as judged by reversed-phase high pressure liquid chromatography analysis (Ultrasyl octyl column, 10 ..mu.. m, 4.6 x 250 mm i.d., 60% MeOH 40% water; flow rate, 1.0 ml/min; retention time for (/sup 18/F) fluorodiazepam, 11.4 min; for diazepam, 13.5 min; radioactivity and ultraviolet detectors). Lower radiochemical yields (5-7%), and significant formation of by-products were observed when (/sup 18/F)acetylhypofluorite, prepared in the gasphase, was used as the reagent. Readily accessible routes to /sup 18/F-labeled benzodiazepines of higher specific activity were also investigated. Approaches to the synthesis of high specific activity (>200 Ci/mmol) (/sup 18/F)3-fluorodiazepam involve nucleophilic displacement at carbon-3 (e.g. from 3-chlorodiazepam) with (/sup 18/F)fluoride ion. The results presented here demonstrate the synthetic accessibility of /sup 18/F-labeled benzodiazepines for application in neurotransmitter ligand studies with PET.

  6. Topographic Effects on the Surface Emissivity of a Mountainous Area Observed by a Spaceborne Microwave Radiometer

    Directory of Open Access Journals (Sweden)

    Frank S. Marzano

    2008-03-01

    Full Text Available A simulation study to understand the influence of topography on the surfaceemissivity observed by a satellite microwave radiometer is carried out. We analyze theeffects due to changes in observation angle, including the rotation of the polarization plane.A mountainous area in the Alps (Northern Italy is considered and the information on therelief extracted from a digital elevation model is exploited. The numerical simulation refersto a radiometric image, acquired by a conically-scanning radiometer similar to AMSR-E,i.e., flying at 705 km of altitude with an observation angle of 55°. To single out the impacton surface emissivity, scattering of the radiation due to the atmosphere or neighboringelevated surfaces is not considered. C and X bands, for which atmospheric effects arenegligible, and Ka band are analyzed. The results indicate that the changes in the localobservation angle tend to lower the apparent emissivity of a radiometric pixel with respectto the corresponding flat surface characteristics. The effect of the rotation of thepolarization plane enlarges (vertical polarization, or attenuates (horizontal polarizationthis decrease. By doing some simplifying assumptions for the radiometer antenna, theconclusion is that the microwave emissivity at vertical polarization is underestimated,whilst the opposite occurs for horizontal polarization, except for Ka band, for which bothunder- and overprediction may occur. A quantification of the differences with respect to aflat soil and an approximate evaluation of their impact on soil moisture retrieval areyielded.

  7. A W-Band Radiometer with the Offset Parabolic Antenna for Radiometric Measurements

    Directory of Open Access Journals (Sweden)

    Li Wu

    2016-01-01

    Full Text Available This paper deals with the development of a W-band noise-adding radiometer which combines the millimeter-wave (MMW radiometric measurements with a high-resolution imager. The offset parabolic antenna is presented to achieve an accurate measurement and a high resolution. To reduce the cross-polarization level of the antenna, a multimode feed horn with a multistep structure is proposed to match the focal region fields of the reflector. It has advantages over the corrugated horns in lower mass and easier manufacturing. In addition, due to an unavoidable settling time for the noise-adding radiometer output signal passing through the low-pass filter, a theoretical criterion for the optimum duty cycle determination to reject extraneous contributions from the transient is proposed in this paper. The appropriate duty cycle threshold is 0.33 for the developed W-band radiometer. Also, a geometric correction method is presented to correct the obtained passive image suffering from a distortion for a better image interpretation. Preliminary experimental results are given to illustrate and verify the presented techniques.

  8. Information theoretic approach using neural network for determining radiometer observations from radar and vice versa

    Science.gov (United States)

    Kannan, Srinivasa Ramanujam; Chandrasekar, V.

    2016-05-01

    Even though both the rain measuring instruments, radar and radiometer onboard the TRMM observe the same rain scenes, they both are fundamentally different instruments. Radar is an active instrument and measures backscatter component from vertical rain structure; whereas radiometer is a passive instrument that obtains integrated observation of full depth of the cloud and rain structure. Further, their spatial resolutions on ground are different. Nevertheless, both the instruments are observing the same rain scene and retrieve three dimensional rainfall products. Hence it is only natural to seek answer to the question, what type of information about radiometric observations can be directly retrieved from radar observations. While there are several ways to answer this question, an informational theoretic approach using neural networks has been described in the present work to find if radiometer observations can be predicted from radar observations. A database of TMI brightness temperature and collocated TRMM vertical attenuation corrected reflectivity factor from the year 2012 was considered. The entire database is further classified according to surface type. Separate neural networks were trained for land and ocean and the results are presented.

  9. Precipitating Snow Retrievals from Combined Airborne Cloud Radar and Millimeter-Wave Radiometer Observations

    Science.gov (United States)

    Grecu, Mircea; Olson, William S.

    2008-01-01

    An algorithm for retrieving snow over oceans from combined cloud radar and millimeter-wave radiometer observations is developed. The algorithm involves the use of physical models to simulate cloud radar and millimeter-wave radiometer observations from basic atmospheric variables such as hydrometeor content, temperature, and relative humidity profiles and is based on an optimal estimation technique to retrieve these variables from actual observations. A high-resolution simulation of a lake-effect snowstorm by a cloud-resolving model is used to test the algorithm. That is, synthetic observations are generated from the output of the cloud numerical model, and the retrieval algorithm is applied to the synthetic data. The algorithm performance is assessed by comparing the retrievals with the reference variables used in synthesizing the observations. The synthetic observation experiment indicates good performance of the retrieval algorithm. The algorithm is also applied to real observations from the Wakasa Bay field experiment that took place over the Sea of Japan in January and February 2003. The application of the retrieval algorithm to data from the field experiment yields snow estimates that are consistent with both the cloud radar and radiometer observations.

  10. Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak.

    Science.gov (United States)

    Kogi, Yuichiro; Sakoda, Takuya; Mase, Atsushi; Ito, Naoki; Yokota, Yuya; Yamaguchi, Soichiro; Nagayama, Yoshio; Jeong, Seung H; Kwon, Myeun; Kawahata, Kazuo

    2008-10-01

    Plasma experiments on KSTAR are scheduled to start up this year (2008). We have developed an electron cyclotron emission (ECE) radiometer to measure the radial electron temperature profiles in KSTAR experiments. The radiometer system consists, briefly, of two downconversion stages, amplifiers, bandpass filter banks, and video detectors. These components are made commercially or developed in house. The system detects ECE power in the frequency range from 110 to 196 GHz, the detected signal being resolved by means of 48 frequency windows. Before installation of this system on KSTAR, we installed a part of this system on large helical device (LHD) to study the system under similar plasma conditions. In this experiment, the signal amplitude, considered to be proportional to the electron temperature, is measured. The time-dependent traces of the electron temperature measured by this radiometer are in good agreement with those provided by the LHD Michelson spectrometer. The system noise level which limits the minimum measurable temperature (converted to the electron temperature) is about 30 eV.

  11. Emissivity measurements in thin metallized membrane reflectors used for microwave radiometer sensors

    Science.gov (United States)

    Schroeder, Lyle C.; Cravey, Robin L.; Scherner, Michael J.; Hearn, Chase P.; Blume, Hans-Juergen C.

    1995-01-01

    This paper is concerned with electromagnetic losses in metallized films used for inflatable reflectors. An inflatable membrane is made of tough elastic material such as Kapton, and it is not electromagnetically reflective by design. A film of conducting metal is added to the membrane to enhance its reflective properties. Since the impetus for use of inflatables for spacecraft is the light weight and compact packaging, it is important that the metal film be as thin as possible. However, if the material is not conductive or thick enough, the radiation due to the emissivity of the reflector could be a significant part of the radiation gathered by the radiometer. The emissivity would be of little consequence to a radar or solar collector; but for a radiometer whose signal is composed of thermal radiation, this contribution could be severe. Bulk properties of the metal film cannot be used to predict its loss. For this reason, a program of analysis and measurement was undertaken to determine the emissivities of a number of candidate metallized film reflectors. This paper describes the three types of measurements which were performed on the metallized thin films: (1) a network analyzer system with an L-band waveguide; (2) an S-band radiometer; and (3) a network analyzer system with a C-band antenna free-space transmission system.

  12. Improved broadband solar irradiance from the multi-filter rotating shadowband radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Michalsky, J.J.; Augustine, J.A. [National Oceanic and Atmospheric Administration, Earth System Research Laboratory, 325 Broadway, Boulder, CO 80305 (United States); Kiedron, P.W. [Cooperative Institute for Research in Environmental Sciences, University of Colorado, 325 Broadway, Boulder, CO 80305 (United States)

    2009-12-15

    Approximations to total and diffuse horizontal and direct normal, broadband solar irradiance (280-4000 nm) can be obtained from the multi-filter rotating shadowband radiometer (MFRSR) using the unfiltered silicon channel of this seven-channel instrument. However, the unfiltered silicon channel only responds to wavelengths between 300 and 1100 nm and does not have a uniform spectral response. In contrast, the best, more expensive, first-class, thermopile-based radiometers respond fairly uniformly to all solar wavelengths. While the total horizontal and direct normal solar irradiance measurements made with the MFRSR unfiltered silicon channel are reasonable if carefully calibrated with a thermopile radiometer, the diffuse horizontal irradiance calibrated in this way has a large bias. These issues are common to all inexpensive, silicon-cell, solar pyranometers. In this paper we use a multivariate, linear regression technique for approximating the thermopile-measured total, diffuse, and direct broadband solar irradiances using the six, narrowband filters and the open-channel of an MFRSR. The calibration of the MFRSR for broadband solar by comparing various combinations of MFRSR channels to first-class thermopile instruments is illustrated, and methods to track the instrument response during field deployments are investigated. We also suggest an approach to calibrate the open-channel for all three components that could improve measurements that are made using typical, commercial, silicon-cell pyranometers. (author)

  13. Imager-to-radiometer inflight cross calibration: RSP radiometric comparison with airborne and satellite sensors

    Directory of Open Access Journals (Sweden)

    J. McCorkel

    2015-10-01

    Full Text Available This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP that takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS, which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI. First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

  14. Category Decomposition Method Based on Matched Filter for Un-Mixing of Mixed Pixels Acquired with Spaceborne Based Hyperspectral Radiometers

    Directory of Open Access Journals (Sweden)

    Kohei Arai

    2013-06-01

    Full Text Available Category decomposition method based on matched filter for un-mixing of mixed pixels: mixels which are acquired with spaceborne based hyperspectral radiometers is proposed. Through simulation studies with simulated mixed pixels which are created with spectral reflectance data derived from USGS spectral library as well as actual airborne based hyperspectral radiometer imagery data, it is found that the proposed method works well with acceptable decomposition accuracy.

  15. Decode the Sodium Label Lingo

    Science.gov (United States)

    ... For Preschooler For Gradeschooler For Teen Decode the Sodium Label Lingo Published January 24, 2013 Print Email Reading food labels can help you slash sodium. Here's how to decipher them. "Sodium free" or " ...

  16. Tritium labeled amino acid conjugates of prostaglandins and thromboxanes as labeled ligands in prostanoid radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Sautebin, L.; Kindahl, H.; Kumlin, M.; Granstroem, E.

    1985-09-01

    Conjugates of prostaglandins and thromboxanes with tritium labeled amino acids were prepared and employed as labeled ligands in prostaglandin and thromboxane radioimmunoassays. Assays for PGF2 alpha, 15-keto-13, 14-dihydro-PGF2 alpha, TXB2 and 15-keto-13,14-dihydro-TXB2 were evaluated in comparative studies using either these heterologous ligands or the corresponding homologous tritiated eicosanoid as tracers. Binding properties for the respective antibodies were found to be similar using either tracer. Three biological studies were also conducted, viz. study of the release of TXB2 during collagen induced platelet aggregation, of 15-keto-13,14-dihydro-TXB2 during guinea pig pulmonary anaphylaxis, and of PGF2 alpha during bovine luteolysis. The analyses gave comparable results using either the heterologous or the homologous assay. Thus, this type of labeled prostanoid conjugates may serve as a convenient alternative to homologous tracers in radioimmunoassay. Heterologous tracers may even in certain cases provide the only simple solution to the problem of preparing a labeled ligand of high specific activity.

  17. Labelling GM-free Products

    DEFF Research Database (Denmark)

    Punt, Maarten; Venus, Thomas; Wesseler, Justus

    2016-01-01

    Food suppliers in the EU must comply with labelling regulations for genetically modified organisms (GMOs). However, excluded from mandatory labelling are food products derived from animals fed with GM feed (mainly GM soybean in the EU). Because of this labelling exemption, consumers are unable to...

  18. Food Labels Tell the Story!

    Science.gov (United States)

    ... My World From the Label to the Table! Food Labels Tell the Story! What is in food? Food provides your body with all of the ... your food choices. Nutrition Facts—the Labels on Food Products Beginning in 1994, the US government began ...

  19. Modeling the effects of labeling

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn; Fjord, Thomas Ahle; Poulsen, Carsten Stig

    A new approach to evaluate the consequences of labeling is presented and applied to test the potential effect of a label on fresh fish. Labeling effects on quality perceptions and overall quality are studied. The empirical study is based on an experimental design and nearly 500 respondents...

  20. Scaffolding Visitors' Learning through Labels

    Science.gov (United States)

    Wang, Joyce; Yoon, Susan

    2013-01-01

    In museum literature, labels have been found to increase visitor learning and contribute to greater cognitive gains. In this study, we seek to understand how various labels support the visitors' learning experience, and specifically in regards to conceptual and cognitive learning. We investigated the increasing use of three types of labels (visual…

  1. A New Generation of Micro Satellite Radiometers for Atmospheric Remote Sensing

    Science.gov (United States)

    He, jieying

    2017-04-01

    The need for low-cost, mission-flexible, and rapidly deployable space borne sensors that meet stringent performance requirements pervades the extreme weather monitoring programs, including especially the strong rainfall and typhoon. New technologies have enabled a novel approach toward this science observational goal, and in this paper we describe recent technology develop efforts to address the challenges above through the use of radiometers on a Micro-sized Microwave Atmospheric Satellite (Microsat), which operates in the type of constellation, and enable the capabilities of rapidly progressing. Recent work has involved the design and development of highly integrated radiometer component technologies that would enable the realization of a high-performance, multi-band sounder that would conform to the 3U CubeSat size (10 x 10 x 30 cm), weight, and power requirements. This paper partly focuses on the constellation to realize a scalable CubeSat-based system that will pave the path towards improved revisit rates over critical earth regions, and achieve state-of-the-art performance relative to current systems with respect to spatial, spectral, and radiometric resolution. As one of the important payloads on the platform, sub-millimeter radiometer is advised to house for providing atmospheric and oceanographic information all weather and all day. The first portion of the radiometer comprises a horn-fed reflector antenna, with a full-width at half-maximum (FWHM) beamwidth of 1.2°. Hence, the scanned beam has an approximate footprint diameter of 9.6 km at nadir incidence from a nominal altitude of 500 km. The antenna system is designed for a minimum 95% beam efficiency. Approximately 98 pixels are sampled for every scanning line, which covers a range of 1500km. The period of a round is about 94.47 minutes and re-visit period is four days. For the radiometer, which is a passive cross-track-scanning microwave spectrometer operating near the 118.75-GHz oxygen absorption

  2. Bayesian Estimation of Precipitation from Satellite Passive Microwave Observations Using Combined Radar-Radiometer Retrievals

    Science.gov (United States)

    Grecu, Mircea; Olson, William S.

    2006-01-01

    Precipitation estimation from satellite passive microwave radiometer observations is a problem that does not have a unique solution that is insensitive to errors in the input data. Traditionally, to make this problem well posed, a priori information derived from physical models or independent, high-quality observations is incorporated into the solution. In the present study, a database of precipitation profiles and associated brightness temperatures is constructed to serve as a priori information in a passive microwave radiometer algorithm. The precipitation profiles are derived from a Tropical Rainfall Measuring Mission (TRMM) combined radar radiometer algorithm, and the brightness temperatures are TRMM Microwave Imager (TMI) observed. Because the observed brightness temperatures are consistent with those derived from a radiative transfer model embedded in the combined algorithm, the precipitation brightness temperature database is considered to be physically consistent. The database examined here is derived from the analysis of a month-long record of TRMM data that yields more than a million profiles of precipitation and associated brightness temperatures. These profiles are clustered into a tractable number of classes based on the local sea surface temperature, a radiometer-based estimate of the echo-top height (the height beyond which the reflectivity drops below 17 dBZ), and brightness temperature principal components. For each class, the mean precipitation profile, brightness temperature principal components, and probability of occurrence are determined. The precipitation brightness temperature database supports a radiometer-only algorithm that incorporates a Bayesian estimation methodology. In the Bayesian framework, precipitation estimates are weighted averages of the mean precipitation values corresponding to the classes in the database, with the weights being determined according to the similarity between the observed brightness temperature principal

  3. Development of radioisotope labeled polymeric carriers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jin; Jeong, Jea Min; Hwang, Hyun Jeong [Ewha Womans University, Seoul (Korea)

    2000-04-01

    This research was performed with the aim of developing polymeric radioisotope or drug carriers for obtaining efficient diagnostic therapeutic efficacy. As polymers, polyethylene oxides, polylactides, polycaprolactone were chosen to prepare the devices including micelle system, microemulsion, nanospheres. In addition, anticancer drug loaded polylactide microparticulates were fabricated as a regional chemotherapeutics for the treatment of cancer. Technetium or radioactive iodine was labeled to the polymeric carriers via ligands such as DTPA and HPP, respectively. Labeling efficiency was above 90% and stable enough up to 24 hours. Moreover, injected polymer carriers demonstrated higher blood maintenance and bone uptake than Tin colloid, a control. These results suggested that radioisotope carrying polymeric particulate are promising tools for diagnosing blood vessels or bones. Besides, anticancer drug loaded particulates demonstrated appropriate maintenance of therapeutic concentration and localization. Therefore it was proposed that this therapeutic system may be potential as a cancer therapy modality. 20 refs., 24 figs.,5 tabs. (Author)

  4. Chelator-Free Labeling of Layered Double Hydroxide Nanoparticles for in Vivo PET Imaging

    Science.gov (United States)

    Shi, Sixiang; Fliss, Brianne C.; Gu, Zi; Zhu, Yian; Hong, Hao; Valdovinos, Hector F.; Hernandez, Reinier; Goel, Shreya; Luo, Haiming; Chen, Feng; Barnhart, Todd E.; Nickles, Robert J.; Xu, Zhi Ping; Cai, Weibo

    2015-11-01

    Layered double hydroxide (LDH) nanomaterial has emerged as a novel delivery agent for biomedical applications due to its unique structure and properties. However, in vivo positron emission tomography (PET) imaging with LDH nanoparticles has not been achieved. The aim of this study is to explore chelator-free labeling of LDH nanoparticles with radioisotopes for in vivo PET imaging. Bivalent cation 64Cu2+ and trivalent cation 44Sc3+ were found to readily label LDH nanoparticles with excellent labeling efficiency and stability, whereas tetravalent cation 89Zr4+ could not label LDH since it does not fit into the LDH crystal structure. PET imaging shows that prominent tumor uptake was achieved in 4T1 breast cancer with 64Cu-LDH-BSA via passive targeting alone (7.7 ± 0.1%ID/g at 16 h post-injection; n = 3). These results support that LDH is a versatile platform that can be labeled with various bivalent and trivalent radiometals without comprising the native properties, highly desirable for PET image-guided drug delivery.

  5. Chelator-Free Labeling of Layered Double Hydroxide Nanoparticles for in Vivo PET Imaging.

    Science.gov (United States)

    Shi, Sixiang; Fliss, Brianne C; Gu, Zi; Zhu, Yian; Hong, Hao; Valdovinos, Hector F; Hernandez, Reinier; Goel, Shreya; Luo, Haiming; Chen, Feng; Barnhart, Todd E; Nickles, Robert J; Xu, Zhi Ping; Cai, Weibo

    2015-11-20

    Layered double hydroxide (LDH) nanomaterial has emerged as a novel delivery agent for biomedical applications due to its unique structure and properties. However, in vivo positron emission tomography (PET) imaging with LDH nanoparticles has not been achieved. The aim of this study is to explore chelator-free labeling of LDH nanoparticles with radioisotopes for in vivo PET imaging. Bivalent cation (64)Cu(2+) and trivalent cation (44)Sc(3+) were found to readily label LDH nanoparticles with excellent labeling efficiency and stability, whereas tetravalent cation (89)Zr(4+) could not label LDH since it does not fit into the LDH crystal structure. PET imaging shows that prominent tumor uptake was achieved in 4T1 breast cancer with (64)Cu-LDH-BSA via passive targeting alone (7.7 ± 0.1%ID/g at 16 h post-injection; n = 3). These results support that LDH is a versatile platform that can be labeled with various bivalent and trivalent radiometals without comprising the native properties, highly desirable for PET image-guided drug delivery.

  6. Map labeling and its generalizations

    Energy Technology Data Exchange (ETDEWEB)

    Doddi, S. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Computer Science]|[Los Alamos National Lab., NM (United States); Marathe, M.V. [Los Alamos National Lab., NM (United States); Mirzaian, A. [York Univ., Toronto, ON (Canada). Dept. of Computer Science; Moret, B.M.E. [New Mexico Univ., Albuquerque, NM (United States). Dept. of Computer Science; Zhu, B. [City Univ. of Hong Kong (Hong Kong). Dept. of Computer Science]|[Los Alamos National Lab., NM (United States)

    1997-01-01

    Map labeling is of fundamental importance in cartography and geographical information systems and is one of the areas targeted for research by the ACM Computational Geometry Impact Task Force. Previous work on map labeling has focused on the problem of placing maximal uniform, axis-aligned, disjoint rectangles on the plane so that each point feature to be labeled lies at the corner of one rectangle. Here, we consider a number of variants of the map labeling problem. We obtain three general types of results. First, we devise constant-factor polynomial-time-approximation algorithms for labeling point features by rectangular labels, where the feature may lie anywhere on the boundary of its label region and where labeling rectangles may be placed in any orientation. These results generalize to the case of elliptical labels. Secondly, we consider the problem of labeling a map consisting of disjoint rectilinear fine segments. We obtain constant-factor polynomial-time approximation algorithms for the general problem and an optimal algorithm for the special case where all segments are horizontal. Finally, we formulate a bicriteria version of the map-labeling problem and provide bicriteria polynomial- time approximation schemes for a number of such problems.

  7. Linerless label device and method

    KAUST Repository

    Binladen, Abdulkari

    2016-01-14

    This apparatus and method for applying a linerless label to an end user product includes a device with a printer for printing on a face surface of a linerless label, and a release coat applicator for applying a release coat to the face surface of the label; another device including an unwinder unit (103) to unwind a roll of printed linerless label; a belt (108); a glue applicator (102) for applying glue to the belt; a nip roller (106) for contacting and applying pressure to the face surface of the linerless label such that the glue on the belt transfers to the back surface of the linerless label; at least one slitting knife 105) positioned downstream the belt and a rewinder unit (104) positioned downstream the slitting knife; and a third device which die cuts and applies the linerless label to an end user object.

  8. Towards a long-term Science Exploitation Plan for the Sea and Land Surface Temperature Radiometer on Sentinel-3 and the Along-Track Scanning Radiometers

    Science.gov (United States)

    Remedios, John J.; Llewellyn-Jones, David

    2014-05-01

    The Sea and Land Surface Temperature Radiometer (SLSTR) on Sentinel-3 is the latest satellite instrument in a series of dual-angle optical and thermal sensors, the Along-Track Scanning Radiometers (ATSRs). Operating on Sentinel-3, the SLSTR has a number of significant improvements compared to the original ATSRs including wider swaths for nadir and dual angles, emphasis on all surface temperature domains, dedicated fire channels and additional cloud channels. The SLSTR therefore provides some excellent opportunities to extend science undertaken with the ATSRs whilst also providing long-term data sets to investigate climate change. The European Space Agency, together with the Department of Energy and Climate Change, sponsored the production of an Exploitation Plan for the ATSRs. In the last year, this been extended to cover the SLSTR also. The plan enables UK and European member states to plan activities related to SLSTR in a long-term context. Covering climate change, oceanography, land surface, atmosphere and cryosphere science, particular attention is paid to the exploitation of long-term data sets. In the case of SLSTR, relevant products include sea, land, lake and ice surface temperatures; aerosols and clouds; fires and gas flares; land surface reflectances. In this presentation, the SLSTR and ATSR science Exploitation Plan will be outlined with emphasis on SLSTR science opportunities, on appropriate co-ordinating mechanisms and on example implementation plans. Particular attention will be paid to the challenges of linking ATSR records with SLSTR to provide consistent long-term data sets, and on the international context of such data sets. The exploitation plan approach to science may prove relevant and useful for other Sentinel instruments.

  9. Labelling analysis for ¹³C MFA using NMR spectroscopy.

    Science.gov (United States)

    Jouhten, Paula; Maaheimo, Hannu

    2014-01-01

    NMR spectroscopy is an efficient method for analyzing (13)C labelling of cellular metabolites. The strength of it is especially the ability to provide direct quantitative positional information on the (13)C labelling status of carbon atoms in metabolites. NMR spectroscopic methods allow also for detection of contiguously (13)C-labelled fragments in the carbon backbones of the metabolites. Furthermore, the recent developments of NMR spectroscopy hardware have substantially improved the sensitivity of the methods. In this chapter we describe a method for analyzing the (13)C labelling of the biomass amino acids for metabolic flux analysis, sample preparation for NMR spectroscopy, acquiring and processing the NMR spectra, and extracting the (13)C labelling information from the NMR data. Different NMR methods are applied depending on the (13)C labelling strategy chosen. These strategies include uniform (13)C labelling, positional (13)C labelling, or a combination of both. Not only the preparation of sample for analysis of (13)C labelling in proteinogenic amino acids in biomass is described, but also the necessary modifications to the method when analysis of (13)C labelling in free metabolic intermediates is of interest. Finally the strategies for using the different NMR-detected (13)C labelling data in (13)C MFA are discussed.

  10. Monoclonal anti-elastin antibody labelled with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Marcia B.N. de; Silva, Claudia R. da; Araujo, Adriano C. de; Bernardo Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Instituto de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia; Porto, Luis Cristovao M.S.; Gutfilen, Bianca [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Instituto de Biologia Roberto Alcantara Gomes; Souza, J.E.Q. [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Centro de Pesquisa Basica; Frier, Malcolm [University Hospital, Nottingham (United Kingdom). Dept. of Medical Physics

    1999-11-01

    Technetium-99m ({sup 99m} Tc) is widely employed in nuclear medicine due to its desirable physical, chemical and biological properties. Moreover, it is easily available and normally is inexpensive. A reducing agent is necessary to label cells and molecules with {sup 99m} Tc and stannous chloride (Sn C L{sub 2}) is usually employed. Elastin is the functional protein component of the elastic fiber and it is related with some diseases such as arteriosclerosis, pulmonary emphysema and others. The present study refers to the preparation of the {sup 99m} Tc labeled monoclonal anti-elastin antibody. The monoclonal antibody was incubated with an excess of 2-iminothiolane. The free thiol groups created, were capable of binding with the reduced technetium. Labeling was an exchange reaction with {sup 99m} Tc-glucoheptonate. The labeled preparation was left at 4 deg C for one hour. Then, it was passed through a Sephadex G50 column. Various fractions were collected and counted. A peak corresponding to the radiolabeled antibody was obtained. Stability studies of the labelled anti-elastin were performed at 0,3 6, 24 hours, at both 4 deg C or room temperature. The biodistribution pattern of the {sup 99m} Tc-anti-elastin was studied in healthy male Swiss mice. The immunoreactivity was also determined. An useful labeled-anti-elastin was obtained to future immunoscintigraphic investigations. (author) 4 refs., 7 figs., 6 tabs.

  11. Preparation and primary application of 125 I labeled triplex-forming oligonucleotide loaded nanoparticles%载125I 标记三螺旋形成寡核苷酸纳米粒的制备及初步应用

    Institute of Scientific and Technical Information of China (English)

    朱姝; 曹素娥; 杨婷; 邹琼; 焦举; 张勇

    2016-01-01

    目的:构建载125 I标记反雄激素受体(AR)基因三螺旋形成寡核苷酸(125 I-TFO)纳米粒,并初步探讨其在体外对前列腺癌细胞的抑制作用。方法应用 Bolton-Hunter 法对三螺旋形成寡核苷酸进行125 I 标记,通过复乳化溶剂挥发法制备包载125 I-TFO 的纳米粒(125 I-TFO-NP),测定其粒径、形态、包封率、载药量及体外释放特点。用γ计数器测定前列腺癌细胞 LNCaP 对125 I-TFO-NP 的摄取情况,CCK-8法检测纳米粒对前列腺癌细胞增殖的抑制作用、荧光定量 PCR 和蛋白免疫印迹法检测纳米粒中 AR mRNA 表达水平。结果所获125 I-TFO 的标记率和放射化学纯度分别为(86.87±0.45)%、(96.21%±0.97)%。125 I-TFO-NP 的平均粒径为(298.2±0.5)nm,包封率与载药量分别为(70.6±6.6)%和(1.89±0.13)μg/mg,缓释作用明显。前列腺癌细胞对125 I-TFO-NP 的摄取率高于未包裹125 I-TFO (P <0.01)。与空白对照组及 TFO-NP 组比较,125 I-TFO-NP 组中前列腺癌细胞的增殖抑制率升高(P <0.01),AR mRNA 及蛋白表达水平均下降(P <0.05)。结论制备的载125 I-TFO-NP性状良好,可通过下调 AR 的表达水平,抑制前列腺癌细胞的增殖。纳米粒可为反基因放射治疗提供理想的载体。%Objective Preparing the 1 25 I labeled anti-androgen receptor (AR)gene triplex-forming oligonucleotide loaded nanoparticles,To investigate the inhibitory effects on prostate cancer cells in vitro. Methods Synthesizing the 1 25 I labeled triplex-forming oligonucleotide by Bolton-Hunter Method,then prepar-ing the 1 25 I labeled triplex-forming oligonucleotide loaded nanoparticles (1 25 I-TFO-NP)by double emulsion sol-vent evaporation method.Its size,shape,embedding ratio and drug loading and release characteristics were i-dentified.The uptake of 1 25 I-TFO-NP by prostate cancer cells was measured by

  12. Immunogold labelling is a quantitative method as demonstrated by studies on aminopeptidase N in microvillar membrane vesicles

    DEFF Research Database (Denmark)

    Hansen, Gert Helge; Wetterberg, L L; Sjöström, H;

    1992-01-01

    Microvillar membrane vesicle preparations with varying content of aminopeptidase N were prepared from enterocytes of the pig small intestine. Postembedding immunogold labelling of aminopeptidase N was performed on these glutaraldehyde/paraformaldehyde-fixed, osmium tetroxide-treated and Epon-embe...... that postembedding immunogold labelling can be used quantitatively....

  13. From Label to Practice

    DEFF Research Database (Denmark)

    Byrkjeflot, Haldor; Strandgaard, Jesper; Svejenova, Silviya

    2013-01-01

    This article examines the process of creation of new Nordic cuisine (NNC) as a culinary innovation, focusing on the main stages, actors, and mechanisms that shaped the new label and its practices and facilitated its diffusion in the region and internationally. Fast-paced diffusion was possible...... because NNC was conceived as an identity movement, triggered by active involvement of entrepreneurial leaders from the culinary profession, high-profile political supporters, legitimating scientists, disseminating media, and interpreting audiences. It was facilitated by three mechanisms: First, the use...

  14. Towards Multi Label Text Classification through Label Propagation

    Directory of Open Access Journals (Sweden)

    Shweta C. Dharmadhikari

    2012-06-01

    Full Text Available Classifying text data has been an active area of research for a long time. Text document is multifaceted object and often inherently ambiguous by nature. Multi-label learning deals with such ambiguous object. Classification of such ambiguous text objects often makes task of classifier difficult while assigning relevant classes to input document. Traditional single label and multi class text classification paradigms cannot efficiently classify such multifaceted text corpus. Through our paper we are proposing a novel label propagation approach based on semi supervised learning for Multi Label Text Classification. Our proposed approach models the relationship between class labels and also effectively represents input text documents. We are using semi supervised learning technique for effective utilization of labeled and unlabeled data for classification. Our proposed approach promises better classification accuracy and handling of complexity and elaborated on the basis of standard datasets such as Enron, Slashdot and Bibtex.

  15. Radio labeling with pre-assigned frequencies

    NARCIS (Netherlands)

    Bodlaender, H.L.; Broersma, H.J.; Fomin, F.V.; Pyatkin, A.V.; Woeginer, G.J.

    2007-01-01

    A radio labeling of a graph G is an assignment of pairwise distinct, positive integer labels to the vertices of G such that labels of adjacent vertices differ by at least 2. The radio labeling problem (RL) consists in determining a radio labeling that minimizes the maximum label that is used (the so

  16. Radio labeling with pre-assigned frequencies

    NARCIS (Netherlands)

    Bodlaender, H.L.; Broersma, H.J.; Fomin, F.V.; Pyatkin, A.V.; Woeginer, G.J.

    2002-01-01

    A radio labeling of a graph G is an assignment of pairwise distinct, positive integer labels to the vertices of G such that labels of adjacent vertices differ by at least 2. The radio labeling problem (RL) consists in determining a radio labeling that minimizes the maximum label that is used (the

  17. Radio labeling with pre-assigned frequencies

    NARCIS (Netherlands)

    Bodlaender, H.L.; Broersma, Haitze J.; Fomin, F.V.; Pyatkin, A.V.; Woeginger, Gerhard

    2002-01-01

    A radio labeling of a graph $G$ is an assignment of pairwise distinct, positive integer labels to the vertices of $G$ such that labels of adjacent vertices differ by at least $2$. The radio labeling problem (\\mbox{\\sc RL}) consists in determining a radio labeling that minimizes the maximum label

  18. Techniques for computing regional radiant emittances of the earth-atmosphere system from observations by wide-angle satellite radiometers, phase 3

    Science.gov (United States)

    Pina, J. F.; House, F. B.

    1975-01-01

    Radiometers on earth orbiting satellites measure the exchange of radiant energy between the earth-atmosphere (E-A) system and space at observation points in space external to the E-A system. Observations by wideangle, spherical and flat radiometers are analyzed and interpreted with regard to the general problem of the earth energy budget (EEB) and to the problem of determining the energy budget of regions smaller than the field of view (FOV) of these radiometers.

  19. Relative Accuracy of 1-Minute and Daily Total Solar Radiation Data for 12 Global and 4 Direct Beam Solar Radiometers: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D. R.; Wilcox, S. M.

    2009-03-01

    This report evaluates the relative performance of 12 global and four direct beam solar radiometers deployed at a single site over a 12-month period. Test radiometer irradiances were compared with a reference irradiance consisting of either an absolute cavity radiometer (during calibrations) or a low uncertainty thermopile pyrheliometer (during the evaluation period) for pyrheliometers; and for pyranometers a reference global irradiance computed from the reference pyrheliometer and diffuse irradiance from a shaded pyranometer.

  20. Tritiation of protein hormones. Progress report. [Stability of tritium-labelled protein hormones

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    A non-catalytic tritium exchange system using a microwave discharge technique was bult and calibrated in order to optomize the labelling of small organic molecules such as benzoic acid. Analytical and preparative chromatographic procedures, including ion exchange and molecular sieve chromatography and polyacrylamide gel electrophoresis, were standardized for use in the publication of tritium and labelled bovine ACTH. Results are reported from extensive studies of the control of chemical and biologic stability of labelled and unlabelled ACTH were carried out.

  1. Tritiation of protein hormones. Progress report. [Stability of tritium-labelled protein hormones

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    A non-catalytic tritium exchange system using a microwave discharge technique was bult and calibrated in order to optomize the labelling of small organic molecules such as benzoic acid. Analytical and preparative chromatographic procedures, including ion exchange and molecular sieve chromatography and polyacrylamide gel electrophoresis, were standardized for use in the publication of tritium and labelled bovine ACTH. Results are reported from extensive studies of the control of chemical and biologic stability of labelled and unlabelled ACTH were carried out.

  2. Sea and Land Surface Temperature Radiometer detection assembly design and performance

    Science.gov (United States)

    Coppo, Peter; Mastrandrea, Carmine; Stagi, Moreno; Calamai, Luciano; Nieke, Jens

    2014-01-01

    The Sea and Land Surface Temperature Radiometers (SLSTRs) are high-accuracy radiometers selected for the Copernicus mission Sentinel-3 space component to provide sea surface temperature (SST) data continuity with respect to previous (Advanced) Along Track Scanning Radiometers [(A)ATSRs] for climatology. Many satellites are foreseen over a 20-year period, each with a 7.5-year lifetime. Sentinel-3A will be launched in 2015 and Sentinel-3B at least six months later, implying that two identical satellites will be maintained in the same orbit with a 180-deg phase delay. Each SLSTR has an improved design with respect to AATSR affording wider near-nadir and oblique view swaths (1400 and 740 km) for SST/land surface temperature global coverage at a 1-km spatial resolution (at SSP) with a daily revisit time (with two satellites), appropriate for both climate and meteorology. Cloud screening and other products are obtained with 0.5 km spatial resolution [at sub-satellite point (SSP)] in visible and short wave infrared (SWIR) bands, while two additional channels are included to monitor high temperature events such as forest fires. The two swaths are obtained with two conical scans and telescopes combined optically at a common focus, representing the input of a cooled focal plane assembly, where nine channels are separated with dichroic and are focalized on detectors with appropriate optical relays. IR and SWIR optics/detectors are cooled to 85 K by an active mechanical cryo-cooler with vibration compensation, while the VIS ones are maintained at a stable temperature. The opto-mechanical design and the expected electro-optical performance of the focal plane assembly are described and the model predictions at system level are compared with experimental data acquired in the vacuum chamber in flight representative thermal conditions or in the laboratory.

  3. Retrieval of atmospheric ozone profiles from an infrared quantum cascade laser heterodyne radiometer: results and analysis.

    Science.gov (United States)

    Weidmann, Damien; Reburn, William J; Smith, Kevin M

    2007-10-10

    Following the recent development of a ground-based prototype quantum cascade laser heterodyne radiometer operating in the midinfrared, atmospheric ozone profile retrievals from a solar occultation measurement campaign performed at the Rutherford Appleton Laboratory on 21 September 2006 are presented. Retrieval is based on the optimal estimation method. High resolution (0.0073 cm(-1)) atmospheric spectra recorded by the laser heterodyne radiometer and covering a microwindow (1033.8-1034.5 cm(-1)) optimized for atmospheric ozone measurements were used as measurement vectors. As part of the evaluation of this novel instrument, a comprehensive analysis of the retrievals is presented, demonstrating the high potential of quantum cascade laser heterodyne radiometry for atmospheric sounding. Vertical resolutions of 2 km near the ground and about 3 km in the stratosphere were obtained. The information content of the retrieval was found to be up to 48 bits, which is much higher than any other passive ground-based instrument. Frequency mismatches of several absorption peaks between the forward model and experimental spectra have been observed and significantly contribute to the retrieval noise error in the upper-troposphere lower-stratosphere region. Retrieved ozone vertical profiles were compared to ozonesonde data recorded at similar latitudes. The agreement is generally excellent except for the 20 to 25 km peak in ozone concentration, where ozonesonde data were found to be 20% lower than the amount retrieved from the laser heterodyne radiometer spectra. Quantum cascade laser based heterodyne radiometry in the midinfrared has been demonstrated to provide high spectral resolution and unprecedented vertical resolution for a passive sounder in a highly compact and mechanically simple package.

  4. Validation of stratospheric temperature profiles from a ground-based microwave radiometer with other techniques

    Science.gov (United States)

    Navas, Francisco; Kämpfer, Niklaus; Haefele, Alexander; Keckhut, Philippe; Hauchecorne, Alain

    2016-04-01

    Vertical profiles of atmospheric temperature trends has become recognized as an important indicator of climate change, because different climate forcing mechanisms exhibit distinct vertical warming and cooling patterns. For example, the cooling of the stratosphere is an indicator for climate change as it provides evidence of natural and anthropogenic climate forcing just like surface warming. Despite its importance, our understanding of the observed stratospheric temperature trend and our ability to test simulations of the stratospheric response to emissions of greenhouse gases and ozone depleting substances remains limited. One of the main reason is because stratospheric long-term datasets are sparse and obtained trends differ from one another. Different techniques allow to measure stratospheric temperature profiles as radiosonde, lidar or satellite. The main advantage of microwave radiometers against these other instruments is a high temporal resolution with a reasonable good spatial resolution. Moreover, the measurement at a fixed location allows to observe local atmospheric dynamics over a long time period, which is crucial for climate research. This study presents an evaluation of the stratospheric temperature profiles from a newly ground-based microwave temperature radiometer (TEMPERA) which has been built and designed at the University of Bern. The measurements from TEMPERA are compared with the ones from other different techniques such as in-situ (radiosondes), active remote sensing (lidar) and passive remote sensing on board of Aura satellite (MLS) measurements. In addition a statistical analysis of the stratospheric temperature obtained from TEMPERA measurements during four years of data has been performed. This analysis evidenced the capability of TEMPERA radiometer to monitor the temperature in the stratosphere for a long-term. The detection of some singular sudden stratospheric warming (SSW) during the analyzed period shows the necessity of these

  5. Measuring Earth Radiation Imbalance from a Massive Constellation of Flux Radiometers

    Science.gov (United States)

    Wiscombe, W. J.; Chiu, J.; Ardanuy, P. E.; Barker, H.; Han, S.; Lorentz, S. R.; Schwartz, S. E.; Trenberth, K. E.

    2012-12-01

    The most important climate variable that is not now measured from space with sufficient accuracy (not even one significant digit on any time scale) is Earth Radiation Imbalance (ERI), a subject of much discussion lately in relation to the "global warming hiatus". The greatest temporal challenges for ERI measurements are very long (decadal) and very short (diurnal) time scales. The decadal challenge is mainly one of calibration and continuity, whereas the diurnal challenge is mainly one of temporal coverage. ERI measurements must meet both challenges. We discuss here a massive constellation of flux radiometers in Low Earth Orbit that is capable of meeting both challenges. At least 30-40 satellites are required for diurnal coverage, an order of magnitude more than in any previous Earth science mission. This same diurnal coverage would make possible, for the first time, the use of ERI measurements in data assimilation, as well as providing a much more temporally resolved dataset for tuning and evaluating climate models. Although a large number of instruments on many satellites might seem to pose a gargantuan calibration challenge, actually, the more satellites, the better the intercalibration: satellites can not only follow each other closely in the same orbit plane, viewing exactly the same scene a few minutes apart, but they can engage in a spider web of crossovers in the polar regions, allowing many further such intercalibrations. Furthermore, keystone satellites can roll over to obtain an absolute calibration from the Sun and deep space, which can then be transferred to the other satellites. Simulations of ERI from such a constellation will be shown, along with the tradeoffs necessary to create an optimal configuration and to mitigate the problems experienced by previous generations of Earth radiation budget radiometers. A tentative instrument design will also be described.Constellation of flux radiometers for measuring Earth Radiation Imbalance

  6. Network operability of ground-based microwave radiometers: Calibration and standardization efforts

    Science.gov (United States)

    Pospichal, Bernhard; Löhnert, Ulrich; Küchler, Nils; Czekala, Harald

    2017-04-01

    Ground-based microwave radiometers (MWR) are already widely used by national weather services and research institutions all around the world. Most of the instruments operate continuously and are beginning to be implemented into data assimilation for atmospheric models. Especially their potential for continuously observing boundary-layer temperature profiles as well as integrated water vapor and cloud liquid water path makes them valuable for improving short-term weather forecasts. However until now, most MWR have been operated as stand-alone instruments. In order to benefit from a network of these instruments, standardization of calibration, operation and data format is necessary. In the frame of TOPROF (COST Action ES1303) several efforts have been undertaken, such as uncertainty and bias assessment, or calibration intercomparison campaigns. The goal was to establish protocols for providing quality controlled (QC) MWR data and their uncertainties. To this end, standardized calibration procedures for MWR have been developed and recommendations for radiometer users compiled. Based on the results of the TOPROF campaigns, a new, high-accuracy liquid-nitrogen calibration load has been introduced for MWR manufactured by Radiometer Physics GmbH (RPG). The new load improves the accuracy of the measurements considerably and will lead to even more reliable atmospheric observations. Next to the recommendations for set-up, calibration and operation of ground-based MWR within a future network, we will present homogenized methods to determine the accuracy of a running calibration as well as means for automatic data quality control. This sets the stage for the planned microwave calibration center at JOYCE (Jülich Observatory for Cloud Evolution), which will be shortly introduced.

  7. Data Fusion Between Microwave and Thermal Infrared Radiometer Data and Its Application to Skin Sea Surface Temperature, Wind Speed and Salinity Retrievals

    Directory of Open Access Journals (Sweden)

    Kohei Arai

    2013-03-01

    Full Text Available Method for data fusion between Microwave Scanning Radiometer: MSR and Thermal Infrared Radiometer: TIR derived skin sea surface temperature: SSST, wind speed: WS and salinity is proposed. SSST can be estimated with MSR and TIR radiometer data. Although the contribution ocean depth to MSR and TIR radiometer data are different each other, SSST estimation can be refined through comparisons between MSR and TIR derived SSST. Also WS and salinity can be estimated with MSR data under the condition of the refined SSST. Simulation study results support the idea of the proposed data fusion method.

  8. Child Nutrition Labeling for Meat and Poultry Products.

    Science.gov (United States)

    Wade, Cheryl; And Others

    Prepared for food manufacturers, this publication contains instructions for calculating the contribution that a meat or poultry product makes toward the meal pattern requirements of child nutrition programs. It also contains instructions on how to apply for and obtain the approval for a label containing a child nutrition statement. These…

  9. Photoaffinity labeling of the lysosomal neuraminidase from bovine testis

    NARCIS (Netherlands)

    G.T.J. van der Horst (Gijsbertus); U. Rose (Ursula); R. Brossmer (Reinhard); F.W. Verheijen (Frans)

    1990-01-01

    markdownabstractAbstract ASA-NeuAc2en, a photoreactive arylazide derivative of sialic acid, is shown to be a powerful competitive inhibitor of lysosomal neuraminidase from bovine testis (Ki ≈ 21 μM). Photoaffinity labeling and partial purification of preparations containing this lysosomal neuramin

  10. High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle

    Science.gov (United States)

    Brown, Shannon T.; Lim, Boon H.; Tanner, Alan B.; Tanabe, Jordan M.; Kangaslahti, Pekka P.; Gaier, Todd C.; Soria, Mary M.; Lambrigtsen, Bjorn H.; Denning, Richard F.; Stachnik, Robert A.

    2012-01-01

    Microwave imaging radiometers operating in the 50-183 GHz range for retrieving atmospheric temperature and water vapor profiles from airborne platforms have been limited in the spatial scales of atmospheric structures that are resolved not because of antenna aperture size, but because of high receiver noise masking the small variations that occur on small spatial scales. Atmospheric variability on short spatial and temporal scales (second/ km scale) is completely unresolved by existing microwave profilers. The solution was to integrate JPL-designed, high-frequency, low-noise-amplifier (LNA) technology into the High-Altitude MMIC Sounding Radiometer (HAMSR), which is an airborne microwave sounding radiometer, to lower the system noise by an order of magnitude to enable the instrument to resolve atmospheric variability on small spatial and temporal scales. HAMSR has eight sounding channels near the 60-GHz oxygen line complex, ten channels near the 118.75-GHz oxygen line, and seven channels near the 183.31-GHz water vapor line. The HAMSR receiver system consists of three heterodyne spectrometers covering the three bands. The antenna system consists of two back-to-back reflectors that rotate together at a programmable scan rate via a stepper motor. A single full rotation includes the swath below the aircraft followed by observations of ambient (roughly 0 C in flight) and heated (70 C) blackbody calibration targets located at the top of the rotation. A field-programmable gate array (FPGA) is used to read the digitized radiometer counts and receive the reflector position from the scan motor encoder, which are then sent to a microprocessor and packed into data files. The microprocessor additionally reads telemetry data from 40 onboard housekeeping channels (containing instrument temperatures), and receives packets from an onboard navigation unit, which provides GPS time and position as well as independent attitude information (e.g., heading, roll, pitch, and yaw). The raw

  11. Measurement of Wind Signatures on the Sea Surface using an L-band Polarimetric Radiometer

    DEFF Research Database (Denmark)

    Søbjærg, Sten Schmidl; Rotbøll, Jesper; Skou, Niels

    2002-01-01

    A series of circle flights have been carried out over the wind driven sea, using the EMIRAD L-band polarimetric radiometer, described in J. Rotboll et al. (2001). Data are calibrated and corrected for aircraft attitude, and 360 degrees azimuth profiles are generated. The results show some variation...... over a full circle, typically about 1 K, and no clear, repeated azimuth signature from circle to circle is identified. Averaging reduces the variations, and frequency analysis of the profiles show an almost flat spectrum, which excludes a simple extrapolation of wind signatures, known at higher...

  12. Investigation of a Real-time Processing System for the NASA Multifrequency Microwave Radiometer

    Science.gov (United States)

    1976-01-01

    A study was conducted to investigate the data reduction and processing requirements for the multifrequency microwave radiometer system (MFMR). The objectives were to develop and evaluate algorithms and processing techniques which might provide for dedicated real time or near real time data processing and to develop a configuration design and processor recommendation to accomplish the data reduction. An analysis of the required data reduction and calibration equations was included along with the identification of sources of error which may be present in the (MFMR) data. The definition and evaluation of the significance of effects introduced by aircraft perturbation was given.

  13. Preliminary Design of the Brazilian's National Institute for Space Research Broadband Radiometer for Solar Observations

    Science.gov (United States)

    Berni, L. A.; Vieira, L. E. A.; Savonov, G. S.; Dal Lago, A.; Mendes, O.; Silva, M. R.; Guarnieri, F.; Sampaio, M.; Barbosa, M. J.; Vilas Boas, J. V.; Branco, R. H. F.; Nishimori, M.; Silva, L. A.; Carlesso, F.; Rodríguez Gómez, J. M.; Alves, L. R.; Vaz Castilho, B.; Santos, J.; Silva Paula, A.; Cardoso, F.

    2017-10-01

    The Total Solar Irradiance (TSI), which is the total radiation arriving at Earth's atmosphere from the Sun, is one of the most important forcing of the Earths climate. Measurements of the TSI have been made employing instruments on board several space-based platforms during the last four solar cycles. However, combining these measurements is still challenging due to the degradation of the sensor elements and the long-term stability of the electronics. Here we describe the preliminary efforts to design an absolute radiometer based on the principle of electrical substitution that is under development at Brazilian's National Institute for Space Research (INPE).

  14. Column Water Vapour using a PFR Radiometer at a High-Alpine Site

    Science.gov (United States)

    Nyeki, S.; Vuilleumier, L.; Heimo, A.; Kämpfer, N.; Mätzler, C.; Vernez, A.; Viatte, P.

    2003-04-01

    The Swiss Atmospheric Radiation Monitoring program (CHARM) integrates a number of solar and atmospheric radiation monitoring tasks within the Swiss contribution to GAW (Global Atmosphere Watch) of the WMO. Columnar water vapor (CWV) is derived from sun photometers at four locations within the CHARM network. A four-year dataset of CWV measured at the Jungfraujoch high-alpine research station (3580 m asl, Switzerland) using a Precision Filter Radiometer (PFR) is reported. Observations indicated that CWV above station altitude varied between 1 and 4 (+/- 1) kg.m-2 in winter and summer, respectively, confirming an earlier 12-month study in 1999.

  15. Millimeter-wave radiometer diagnostics of harmonic electron cyclotron emission in the Levitated Dipole Experiment.

    Science.gov (United States)

    Woskov, P P; Kesner, J; Garnier, D T; Mauel, M E

    2010-10-01

    A 110/137 GHz radiometer pair with collimated antenna pattern is being used to diagnose optically thin harmonic electron cyclotron emission from hot electrons in LDX. Signal levels of 0.1-1 keV and 110/137 ratios of 2-4 stationary with ECRH power have been observed. The large plasma core magnetic field gradient causes all relevant harmonics to be simultaneously viewed over a angle(k,B) angular range of 0°-90° representing a unique geometry for interpretation of ECE in terms of hot electron temperature and density.

  16. Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer

    Science.gov (United States)

    Little, John

    2013-01-01

    Advancements in common aperture antenna technology were employed to utilize its proprietary genetic algorithmbased modeling tools in an effort to develop, build, and test a dual-polarization array for Hurricane Imaging Radiometer (HIRAD) applications. Final program results demonstrate the ability to achieve a lightweight, thin, higher-gain aperture that covers the desired spectral band. NASA employs various passive microwave and millimeter-wave instruments, such as spectral radiometers, for a range of remote sensing applications, from measurements of the Earth's surface and atmosphere, to cosmic background emission. These instruments such as the HIRAD, SFMR (Stepped Frequency Microwave Radiometer), and LRR (Lightweight Rainfall Radiometer), provide unique data accumulation capabilities for observing sea surface wind, temperature, and rainfall, and significantly enhance the understanding and predictability of hurricane intensity. These microwave instruments require extremely efficient wideband or multiband antennas in order to conserve space on the airborne platform. In addition, the thickness and weight of the antenna arrays is of paramount importance in reducing platform drag, permitting greater time on station. Current sensors are often heavy, single- polarization, or limited in frequency coverage. The ideal wideband antenna will have reduced size, weight, and profile (a conformal construct) without sacrificing optimum performance. The technology applied to this new HIRAD array will allow NASA, NOAA, and other users to gather information related to hurricanes and other tropical storms more cost effectively without sacrificing sensor performance or the aircraft time on station. The results of the initial analysis and numerical design indicated strong potential for an antenna array that would satisfy all of the design requirements for a replacement HIRAD array. Multiple common aperture antenna methodologies were employed to achieve exceptional gain over the entire

  17. Sentinel-3 MWR Microwave Radiometer – Our contribution to the success of the Copernicus programme

    Directory of Open Access Journals (Sweden)

    M.A. Palacios

    2014-06-01

    Full Text Available The MWR builds, together with the SRAL altimeter, the S3 topography mission. The MWR, developed by EADS CASA Espacio as prime contractor, provides information for tropospheric path correction of SRAL measurements. MWR data can also be used for determining surface emissivity and soil moisture over land, surface energy budget investigations and ice characterization. The MWR instrument is a Noise Injection Radiometer (NIR, working at two frequencies (23.8/36.5 GHz, embarking a dual frequency horn antenna pointing to the cold sky for embedded autonomous calibration.

  18. Microwave Radiometer Networks for Measurement of the Spatio-Temporal Variability of Water Vapor

    Science.gov (United States)

    Reising, S. C.; Iturbide-Sanchez, F.; Padmanabhan, S.

    2006-12-01

    Tropospheric water vapor plays a key role in the prediction of convective storm initiation, precipitation and extreme weather events. Conventionally, water vapor profiles are derived from dewpoint and temperature measurements using instrumented weather balloons, including radiosondes. These balloons take approximately one hour to measure from surface to tropopause, and transmitter-sensor packages cannot be reused. Such in-situ measurements provide profiles with very high vertical resolution but with severe limitations in temporal and spatial coverage. Raman lidars use active optical techniques to provide comparable vertical resolution and measurement accuracy to radiosondes. However, these lidars are bulky and expensive, and their operation is limited to clear-sky conditions due to the high optical opacity of clouds. Microwave radiometers provide path-integrated water vapor and liquid water with high temporal resolution during nearly all weather conditions. If multiple frequencies are measured near the water vapor resonance, coarse vertical profiles can be obtained using statistical inversion. Motivated by the need for improved temporal and spatial resolutions, a network of elevation and azimuth scanning radiometers is being developed to provide coordinated volumetric measurements of tropospheric water vapor. To realize this network, two Miniaturized Water Vapor profiling Radiometers (MVWR) have been designed and fabricated at Colorado State University. MWVR is small, light-weight, consumes little power and is highly stable. To reduce the mass, volume, cost and power consumption as compared to traditional waveguide techniques, MWVR was designed based on monolithic microwave integrated-circuit technology developed for the wireless communication and defense industries. It was designed for network operation, in which each radiometer will perform a complete volumetric scan within a few minutes, and overlapping scans from multiple sensors will be combined

  19. Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

    Science.gov (United States)

    Foukal, Peter V.; Hoyt, C.; Kochling, H.; Miller, P.

    1990-01-01

    The dramatic improvement in heat diffusivity of pure Cu at liquid-He temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table-top cryogenic ESR now available for detector calibration work to the 0.01-percent level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently delivered to the NIST for radiometric calibrations of black bodies is also described, along with the design and testing of a very fast cryogenic ESR developed for NASA remote-sensing studies of the earth's radiation budget.

  20. Modelling of the L-band brightness temperatures measured with ELBARA III radiometer on Bubnow wetland

    Science.gov (United States)

    Gluba, Lukasz; Sagan, Joanna; Lukowski, Mateusz; Szlazak, Radoslaw; Usowicz, Boguslaw

    2017-04-01

    Microwave radiometry has become the main tool for investigating soil moisture (SM) with remote sensing methods. ESA - SMOS (Soil Moisture and Ocean Salinity) satellite operating at L-band provides global distribution of soil moisture. An integral part of SMOS mission are calibration and validation activities involving measurements with ELBARA III which is an L-band microwave passive radiometer. It is done in order to improve soil moisture retrievals - make them more time-effective and accurate. The instrument is located at Bubnow test-site, on the border of cultivated field, fallow, meadow and natural wetland being a part of Polesie National Park (Poland). We obtain both temporal and spatial dependences of brightness temperatures for varied types of land covers with the ELBARA III directed at different azimuths. Soil moisture is retrieved from brightness temperature using L-band Microwave Emission of the Biosphere (L-MEB) model, the same as currently used radiative transfer model for SMOS. Parametrization of L-MEB, as well as input values are still under debate. We discuss the results of SM retrievals basing on data obtained during first year of the radiometer's operation. We analyze temporal dependences of retrieved SM for one-parameter (SM), two-parameter (SM, τ - optical depth) and three-parameter (SM, τ, Hr - roughness parameter) retrievals, as well as spatial dependences for specific dates. Special case of Simplified Roughness Parametrization, combining the roughness parameter and optical depth, is considered. L-MEB processing is supported by the continuous measurements of soil moisture and temperature obtained from nearby agrometeorological station, as well as studies on the soil granulometric composition of the Bubnow test-site area. Furthermore, for better estimation of optical depth, the satellite-derived Normalized Difference Vegetation Index (NDVI) was employed, supported by measured in situ vegetation parameters (such as Leaf Area Index and Vegetation

  1. Development of the mechanical cryocooler system for the Sea Land Surface Temperature Radiometer

    Science.gov (United States)

    Camilletti, Adam; Burgess, Christopher; Donchev, Anton; Watson, Stuart; Weatherstone Akbar, Shane; Gamo-Albero, Victoria; Romero-Largacha, Victor; Caballero-Olmo, Gema

    2014-11-01

    The Sea Land Surface Temperature Radiometer is a dual view Earth observing instrument developed as part of the European Global Monitoring for Environment and Security programme. It is scheduled for launch on two satellites, Sentinel 3A and 3B in 2014. The instrument detectors are cooled to below 85 K by two split Stirling Cryocoolers running in hot redundancy. These coolers form part of a cryocooler system that includes a support structure and drive electronics. Aspects of the system design, including control and reduction of exported vibration are discussed; and results, including thermal performance and exported vibration from the Engineering Model Cryooler System test campaign are presented.

  2. Results from the pushbroom microwave radiometer flights over the Konza Prairie in 1985

    Science.gov (United States)

    Schmugge, T. J.; Wang, J. R.; Lawrence, R. W.

    1987-01-01

    Four flights were conducted by the NASA C-130 aircraft sensor platform bearing the 'pushbroom' microwave radiometer (PBMR) over the Konza Prairie in central Kansas in 1985, in order to monitor soil surface variations. When the brightness temperature maps thus obtained were analyzed, a striking difference was noted between burned and unburned watersheds; the latter had a very high emissivity despite having saturated soils, while the former had low values that increased with the gradual drying of the soils. The lack of sensitivity for the unburned watershed is tentatively attributed to the build-up of a thatch layer by the decaying vegetation, which serves as a good microwave absorber when wet.

  3. MERITXELL: The Multifrequency Experimental Radiometer with Interference Tracking for Experiments over Land and Littoral-Instrument Description, Calibration and Performance.

    Science.gov (United States)

    Querol, Jorge; Tarongí, José Miguel; Forte, Giuseppe; Gómez, José Javier; Camps, Adriano

    2017-05-10

    MERITXELL is a ground-based multisensor instrument that includes a multiband dual-polarization radiometer, a GNSS reflectometer, and several optical sensors. Its main goals are twofold: to test data fusion techniques, and to develop Radio-Frequency Interference (RFI) detection, localization and mitigation techniques. The former is necessary to retrieve complementary data useful to develop geophysical models with improved accuracy, whereas the latter aims at solving one of the most important problems of microwave radiometry. This paper describes the hardware design, the instrument control architecture, the calibration of the radiometer, and several captures of RFI signals taken with MERITXELL in urban environment. The multiband radiometer has a dual linear polarization total-power radiometer topology, and it covers the L-, S-, C-, X-, K-, Ka-, and W-band. Its back-end stage is based on a spectrum analyzer structure which allows to perform real-time signal processing, while the rest of the sensors are controlled by a host computer where the off-line processing takes place. The calibration of the radiometer is performed using the hot-cold load procedure, together with the tipping curves technique in the case of the five upper frequency bands. Finally, some captures of RFI signals are shown for most of the radiometric bands under analysis, which evidence the problem of RFI in microwave radiometry, and the limitations they impose in external calibration.

  4. MERITXELL: The Multifrequency Experimental Radiometer with Interference Tracking for Experiments over Land and Littoral—Instrument Description, Calibration and Performance

    Science.gov (United States)

    Querol, Jorge; Tarongí, José Miguel; Forte, Giuseppe; Gómez, José Javier; Camps, Adriano

    2017-01-01

    MERITXELL is a ground-based multisensor instrument that includes a multiband dual-polarization radiometer, a GNSS reflectometer, and several optical sensors. Its main goals are twofold: to test data fusion techniques, and to develop Radio-Frequency Interference (RFI) detection, localization and mitigation techniques. The former is necessary to retrieve complementary data useful to develop geophysical models with improved accuracy, whereas the latter aims at solving one of the most important problems of microwave radiometry. This paper describes the hardware design, the instrument control architecture, the calibration of the radiometer, and several captures of RFI signals taken with MERITXELL in urban environment. The multiband radiometer has a dual linear polarization total-power radiometer topology, and it covers the L-, S-, C-, X-, K-, Ka-, and W-band. Its back-end stage is based on a spectrum analyzer structure which allows to perform real-time signal processing, while the rest of the sensors are controlled by a host computer where the off-line processing takes place. The calibration of the radiometer is performed using the hot-cold load procedure, together with the tipping curves technique in the case of the five upper frequency bands. Finally, some captures of RFI signals are shown for most of the radiometric bands under analysis, which evidence the problem of RFI in microwave radiometry, and the limitations they impose in external calibration. PMID:28489056

  5. GEO label: The General Framework for Labeling and Certification

    Science.gov (United States)

    Bye, B. L.; McCallum, I.; Maso, J.

    2012-04-01

    The Group on Earth Observations (GEO) is coordinating efforts to build a Global Earth Observation System of Systems, or GEOSS. As part of a strategy to increase the involvement of the science and technology community in GEOSS, both as users and developers of GEOSS itself, GEO decided to develop a GEO label concept related to the scientific relevance, quality, acceptance and societal needs for services and data sets of GEOSS. The development of a GEO label is included in the GEO work plan and several projects address the challenges of developing a GEO label concept. Within the different projects developing the GEO label, various perspectives and approaches are being applied. In order to arrive at a generally accepted GEO label concept, a common understanding and basic knowledge of labeling is necessary. Assessment of quality of internationally standardized Earth observation data products implies possible certification. A general understanding of the framework for international standards and certification will also contribute to a more coherent discussion and more efficient development of a GEO label. We will describe the general labeling and certification framework emphasizing the relation to the three elements of the GEO label: quality, user acceptance and relevance. Based on a survey of international labels done by the EGIDA project, we have analyzed the legal framework and organization of labels and certification. We will discuss the frameworks for certification, user ratings, registration and analysis of user requirements. Quality assessment is a particular focus of the analysis and is based on the work done by the GeoViQua project. A GEO label will function both as a data distribution strategy and as a general management system for data. Through a label users can compare different data sets and get access to more information about the relevant data, including quality. A label will provide traceability of data both in the interest of users as well as data

  6. Homogeneous Biosensing Based on Magnetic Particle Labels

    KAUST Repository

    Schrittwieser, Stefan

    2016-06-06

    The growing availability of biomarker panels for molecular diagnostics is leading to an increasing need for fast and sensitive biosensing technologies that are applicable to point-of-care testing. In that regard, homogeneous measurement principles are especially relevant as they usually do not require extensive sample preparation procedures, thus reducing the total analysis time and maximizing ease-of-use. In this review, we focus on homogeneous biosensors for the in vitro detection of biomarkers. Within this broad range of biosensors, we concentrate on methods that apply magnetic particle labels. The advantage of such methods lies in the added possibility to manipulate the particle labels by applied magnetic fields, which can be exploited, for example, to decrease incubation times or to enhance the signal-to-noise-ratio of the measurement signal by applying frequency-selective detection. In our review, we discriminate the corresponding methods based on the nature of the acquired measurement signal, which can either be based on magnetic or optical detection. The underlying measurement principles of the different techniques are discussed, and biosensing examples for all techniques are reported, thereby demonstrating the broad applicability of homogeneous in vitro biosensing based on magnetic particle label actuation.

  7. Sustainability labels on food products

    DEFF Research Database (Denmark)

    Grunert, Klaus G; Hieke, Sophie; Wills, Josephine

    2014-01-01

    This study investigates the relationship between consumer motivation, understanding and use of sustainability labels on food products (both environmental and ethical labels), which are increasingly appearing on food products. Data was collected by means of an online survey implemented in the UK......, human values as measured by the Schwartz value domains, and country differences. The results imply that sustainability labels currently do not play a major role in consumers’ food choices, and future use of these labels will depend on the extent to which consumers’ general concern about sustainability...

  8. Differential isotope-labeling for Leu and Val residues in a protein by E. coli cellular expression using stereo-specifically methyl labeled amino acids

    Energy Technology Data Exchange (ETDEWEB)

    Miyanoiri, Yohei; Takeda, Mitsuhiro [Nagoya University, Structural Biology Research Center, Graduate School of Science (Japan); Okuma, Kosuke; Ono, Akira M.; Terauchi, Tsutomu [Tokyo Metropolitan University, Center for Priority Areas (Japan); Kainosho, Masatsune, E-mail: kainosho@tmu.ac.jp [Nagoya University, Structural Biology Research Center, Graduate School of Science (Japan)

    2013-09-21

    The {sup 1}H–{sup 13}C HMQC signals of the {sup 13}CH{sub 3} moieties of Ile, Leu, and Val residues, in an otherwise deuterated background, exhibit narrow line-widths, and thus are useful for investigating the structures and dynamics of larger proteins. This approach, named methyl TROSY, is economical as compared to laborious methods using chemically synthesized site- and stereo-specifically isotope-labeled amino acids, such as stereo-array isotope labeling amino acids, since moderately priced, commercially available isotope-labeled α-keto acid precursors can be used to prepare the necessary protein samples. The Ile δ{sub 1}-methyls can be selectively labeled, using isotope-labeled α-ketobutyrates as precursors. However, it is still difficult to prepare a residue-selectively Leu and Val labeled protein, since these residues share a common biosynthetic intermediate, α-ketoisovalerate. Another hindering drawback in using the α-ketoisovalerate precursor is the lack of stereo-selectivity for Leu and Val methyls. Here we present a differential labeling method for Leu and Val residues, using four kinds of stereo-specifically {sup 13}CH{sub 3}-labeled [U–{sup 2}H;{sup 15}N]-leucine and -valine, which can be efficiently incorporated into a protein using Escherichia coli cellular expression. The method allows the differential labeling of Leu and Val residues with any combination of stereo-specifically isotope-labeled prochiral methyls. Since relatively small amounts of labeled leucine and valine are required to prepare the NMR samples; i.e., 2 and 10 mg/100 mL of culture for leucine and valine, respectively, with sufficient isotope incorporation efficiency, this approach will be a good alternative to the precursor methods. The feasibility of the method is demonstrated for 82 kDa malate synthase G.

  9. 76 FR 75809 - Prior Label Approval System: Generic Label Approval

    Science.gov (United States)

    2011-12-05

    ... Food Standards and Labeling Policy Book; does not bear any special claims, such as quality claims... addition, deletion, or amendment of recipe suggestions for the product; j. Any change in punctuation; k... Policy Book, and questions and answers on various topics, such as irradiation and the labeling...

  10. Island based radar and microwave radiometer measurements of stratus cloud parameters during the Atlantic Stratocumulus Transition Experiment (ASTEX)

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, A.S. [Colorado State Univ., Fort Collins, CO (United States); Fairall, C.W.; Snider, J.B. [NOAA Environmental Technology Lab., Boulder, CO (United States); Lenshow, D.H.; Mayer, S.D. [National Center for Atmospheric Research, Boulder, CO (United States)

    1996-04-01

    During the Atlantic Stratocumulus Transition Experiment (ASTEX) in June 1992, simultaneous measurements were made with a vertically pointing cloud sensing radar and a microwave radiometer. The radar measurements are used to estimate stratus cloud drizzle and turbulence parameters. In addition, with the microwave radiometer measurements of reflectivity, we estimated the profiles of cloud liquid water and effective radius. We used radar data for computation of vertical profiles of various drizzle parameters such as droplet concentration, modal radius, and spread. A sample of these results is shown in Figure 1. In addition, in non-drizzle clouds, with the radar and radiometer we can estimate the verticle profiles of stratus cloud parameters such as liquid water concentration and effective radius. This is accomplished by assuming a droplet distribution with droplet number concentration and width constant with height.

  11. A synthetic approach to carbon-14 labeled anti-bacterial naphthyridine and quinolone carboxylic acids

    Energy Technology Data Exchange (ETDEWEB)

    Ekhato, I.V.; Huang, C.C. (Parke, Davis and Co., Ann Arbor, MI (United States))

    1993-09-01

    Labeled versions of (S)-clinafloxacin (1) and two napththyridine carboxylic acid anti-bacterial compounds 2 and 3 which are currently in development were synthesized. Preparations started from hitherto unknown bromo compounds 22 and 10, from which the corresponding [sup 14]C-labeled aromatic carboxylic acids 23 and 12 were generated by metal-halogen exchange followed by carboxylation reaction. Details of these preparations are given. (author).

  12. A preliminary assessment of the sea surface wind speed production of HY-2 scanning microwave radiometer

    Institute of Scientific and Technical Information of China (English)

    HUANG Xiaoqi; ZHU Jianhua; LIN Mingsen; ZHAO Yili; WANG He; CHEN Chuntao; PENG Hailong; ZHANG Youguang

    2014-01-01

    A scanning microwave radiometer (RM) was launched on August 16, 2011, on board HY-2 satellite. The six-month long global sea surface wind speeds observed by the HY-2 scanning microwave radiometer are preliminarily validated using in-situ measurements and WindSat observations, respectively, from January to June 2012. The wind speed root-mean-square (RMS) difference of the comparisons with in-situ data is 1.89 m/s for the measurements of NDBC and 1.72 m/s for the recent four-month data measured by PY30-1 oil platform, respectively. On a global scale, the wind speeds of HY-2 RM are compared with the sea surface wind speeds derived from WindSat, the RMS difference of 1.85 m/s for HY-2 RM collocated observations data set is calculated in the same period as above. With analyzing the global map of a mean difference between HY-2 RM and WindSat, it appears that the bias of the sea surface wind speed is obviously higher in the inshore regions. In the open sea, there is a relatively higher positive bias in the mid-latitude regions due to the overestimation of wind speed observations, while the wind speeds are underestimated in the Southern Ocean by HY-2 RM relative to WindSat observations.

  13. Cooled infrared filters and dichroics for the sea and land surface temperature radiometer.

    Science.gov (United States)

    Hawkins, Gary; Sherwood, Richard; Djotni, Karim; Coppo, Peter; Höhnemann, Holger; Belli, Fabio

    2013-04-01

    The sea and land surface temperature radiometer (SLSTR) is a nine-channel visible and infrared high-precision radiometer designed to provide climate data of global sea and land surface temperatures. The SLSTR payload is destined to fly on the Ocean and Medium-Resolution Land Mission for the ESA/EU global monitoring for environment and security (GMES) programme Sentinel-3 mission to measure the sea and land temperature and topography for near real-time environmental and atmospheric climate monitoring of the Earth. In this paper we describe the optical layout of infrared optics in the instrument, the spectral thin-film multilayer design, and the system channel throughput analysis for the combined interference filter and dichroic beam splitter coatings to discriminate wavelengths at 3.74, 10.85, 12.0 μm. The rationale for selection of thin-film materials, the deposition technique, and environmental testing, inclusive of humidity, thermal cycling, and ionizing radiation testing are also described.

  14. Track structure simulation for positron emitters of physical interest. Part II: The case of the radiometals

    Science.gov (United States)

    Le Loirec, C.; Champion, C.

    2007-11-01

    The development of radiochemical services in hospitals, due to the wide use of Positron Emission Tomography (PET) in nuclear medicine, has led to the synthesis of new radiotracers among them radiometals which present a large panel of advantages in terms of half-life times and emission spectra. The most encouraging are the copper isotopes 62Cu and 64Cu as well as 60Cu and 61Cu and the technetium isotope 94mTc used for diagnosis and pharmacokinetic studies. The manganese isotopes 52mMn, 52Mn and 51Mn also present some interesting characteristics, especially 52mMn produced during the decay of 52Fe. Finally, the less known isotopes 89Zr, 45Ti, and 86Y can also be used as surrogates of some therapeutic agents, whereas 38K, 55Co and 66Ga may be used as PET imaging tracers. In this work, we propose an intercomparison of these PET radiometal isotopes. To do that, we have used the home-made Monte Carlo simulation previously described in Champion and Le Loirec [Phys. Med. Biol. 51 (2006) 1707] to simulate the complete decay of β + tracers in biological matter. Under these conditions, we access to a complete description of the positronic irradiation during PET exams using metallic isotopes. The results obtained are also compared with existing theoretical and experimental data and good agreement is generally observed.

  15. Microwave Radiometers for Fire Detection in Trains: Theory and Feasibility Study †

    Science.gov (United States)

    Alimenti, Federico; Roselli, Luca; Bonafoni, Stefania

    2016-01-01

    This paper introduces the theory of fire detection in moving vehicles by microwave radiometers. The system analysis is discussed and a feasibility study is illustrated on the basis of two implementation hypotheses. The basic idea is to have a fixed radiometer and to look inside the glass windows of the wagon when it passes in front of the instrument antenna. The proposed sensor uses a three-pixel multi-beam configuration that allows an image to be formed by the movement of the train itself. Each pixel is constituted by a direct amplification microwave receiver operating at 31.4 GHz. At this frequency, the antenna can be a 34 cm offset parabolic dish, whereas a 1 K brightness temperature resolution is achievable with an overall system noise figure of 6 dB, an observation bandwidth of 2 GHz and an integration time of 1 ms. The effect of the detector noise is also investigated and several implementation hypotheses are discussed. The presented study is important since it could be applied to the automatic fire alarm in trains and moving vehicles with dielectric wall/windows. PMID:27322280

  16. Microwave Radiometers for Fire Detection in Trains: Theory and Feasibility Study

    Directory of Open Access Journals (Sweden)

    Federico Alimenti

    2016-06-01

    Full Text Available This paper introduces the theory of fire detection in moving vehicles by microwave radiometers. The system analysis is discussed and a feasibility study is illustrated on the basis of two implementation hypotheses. The basic idea is to have a fixed radiometer and to look inside the glass windows of the wagon when it passes in front of the instrument antenna. The proposed sensor uses a three-pixel multi-beam configuration that allows an image to be formed by the movement of the train itself. Each pixel is constituted by a direct amplification microwave receiver operating at 31.4 GHz. At this frequency, the antenna can be a 34 cm offset parabolic dish, whereas a 1 K brightness temperature resolution is achievable with an overall system noise figure of 6 dB, an observation bandwidth of 2 GHz and an integration time of 1 ms. The effect of the detector noise is also investigated and several implementation hypotheses are discussed. The presented study is important since it could be applied to the automatic fire alarm in trains and moving vehicles with dielectric wall/windows.

  17. Cloud Optical Properties from the Multifilter Shadowband Radiometer (MFRSRCLDOD). An ARM Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Turner, D. D. [DOE ARM Climate Research Facility, Washington, DC (United States); McFarlane, S. A. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. [DOE ARM Climate Research Facility, Washington, DC (United States); Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Shi, Y. [DOE ARM Climate Research Facility, Washington, DC (United States); Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lo, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Min, Q. [State University of New York, Albany; DOE ARM Climate Research Facility, Washington, DC (United States)

    2014-02-01

    The microphysical properties of clouds play an important role in studies of global climate change. Observations from satellites and surface-based systems have been used to infer cloud optical depth and effective radius. Min and Harrison (1996) developed an inversion method to infer the optical depth of liquid water clouds from narrow band spectral Multifilter Rotating Shadowband Radiometer (MFRSR) measurements (Harrison et al. 1994). Their retrieval also uses the total liquid water path (LWP) measured by a microwave radiometer (MWR) to obtain the effective radius of the warm cloud droplets. Their results were compared with Geostationary Operational Environmental Satellite (GOES) retrieved values at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site (Min and Harrison 1996). Min et al. (2003) also validated the retrieved cloud optical properties against in situ observations, showing that the retrieved cloud effective radius agreed well with the in situ forward scattering spectrometer probe observations. The retrieved cloud optical properties from Min et al. (2003) were used also as inputs to an atmospheric shortwave model, and the computed fluxes were compared with surface pyranometer observations.

  18. Optical component performance for the Ocean Radiometer for Carbon Assessment (ORCA)

    Science.gov (United States)

    Quijada, Manuel A.; Wilson, Mark; Waluschka, Eugene; McClain, Charles R.

    2011-10-01

    The Ocean Radiometer for Carbon Assessment (ORCA) is a new design for the next generation remote sensing of ocean biology and biogeochemistry. ORCA is configured to meet all the measurement requirements of the Decadal Survey Aerosol, Cloud, and Ecology (ACE ), the Ocean Ecosystem (OES) radiometer and the Pre-ACE climate data continuity mission (PACE). Under the auspices of a 2007 grant from NASA Research Opportunity in Space and Earth Science (ROSES) and the Instrument Incubator Program (IIP) , a team at the Goddard Space Flight Center (GSFC) has been working on a functional prototype with flightlike fore and aft optics and scan mechanisms. As part of the development efforts to bring ORCA closer to a flight configuration, we have conducted component-level optical testing using standard spectrophometers and system-level characterizations using nonflight commercial off-the-shelf (COTS) focal plane array detectors. Although these arrays would not be able to handle flight data rates, they are adequate for optical alignment and performance testing. The purpose of this presentation is to describe the results of this testing performed at GSFC and the National Institute of Standards and Technology (NIST) at the component and system level. Specifically, we show results for ORCA's spectral calibration ranging from the near UV, visible, and near-infrared spectral regions.

  19. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  20. Microwave radiometer to retrieve temperature profiles from the surface to the stratopause

    Directory of Open Access Journals (Sweden)

    O. Stähli

    2013-09-01

    Full Text Available TEMPERA (TEMPERature RAdiometer is a new ground-based radiometer which measures in a frequency range from 51–57 GHz radiation emitted by the atmosphere. With this instrument it is possible to measure temperature profiles from ground to about 50 km. This is the first ground-based instrument with the capability to retrieve temperature profiles simultaneously for the troposphere and stratosphere. The measurement is done with a filterbank in combination with a digital fast Fourier transform spectrometer. A hot load and a noise diode are used as stable calibration sources. The optics consist of an off-axis parabolic mirror to collect the sky radiation. Due to the Zeeman effect on the emission lines used, the maximum height for the temperature retrieval is about 50 km. The effect is apparent in the measured spectra. The performance of TEMPERA is validated by comparison with nearby radiosonde and satellite data from the Microwave Limb Sounder on the Aura satellite. In this paper we present the design and measurement method of the instrument followed by a description of the retrieval method, together with a validation of TEMPERA data over its first year, 2012.